HomeMy WebLinkAbout2015-08-18-PB-FINALTOWN OF ULYSSES
PLANNING BOARD
MEETING MINUTES
August 18, 2015
Approved: 9/1/15
Present: Chairman John Wertis; Board Members Sarah Adams, David Blake, David Diaz, and
Craig Salino; Environmental Planner Darby Kiley; Town Board Liaison Richard Goldman.
Members of the Public Present: Melissa Kemp of Renovus Energy
Call to Order at: 7 p.m.
Agenda Review; Minutes Review (08/04/2015)
Mr. Blake MADE the MOTION to accept the August 4, 2015 meeting minutes with a minor
clarification, and Mr. Salino SECONDED the MOTION. The meeting minutes were
unanimously approved.
Solar Regulations
Ms. Adams cautioned that the Planning Board could get bogged down with details on solar
regulations.
Ms. Kemp arrived at 7:06 p.m. and, prompted by a question by Mr. Wertis, the Planning Board
H' S 1LRL3NHIDRD1E32XLLLlRLM ILROJM C30HtL=
Ms. Adams continued, saying it is important to keep a timeline in mind. Future changes may be
necessary with proposed regulations, but, for now, the Geneva law is a good start. She reached
out to the Geneva Planning office and was told that a provision permitting major solar farm
systems in all districts is beginning to cause problems for the Town of Geneva. They are starting
the process of revising their law, Ms. Adams said.
Mr. Wertis asked Ms. Adams if there were any specific items that needed to be addressed within
QRZ mow. After a discussion, Board members outlined concerns relative to setbacks,
height, and square footage limits for solar arrays.
On the subject of height, Ms. Kiley informed the Planning Board that any roof -mounted solar
LLLMP RZ feet height limit on structures would require a variance
issued by the Board of Zoning Appeals. As previously noted by Mr. Wertis, Site Plan Review is
another option for considering a roof -P RZ feet
maximum height. Ms. Kiley said the Planning Board may choose to increase the height
maximum for ground -mounted arrays from 15 to 20 feet.
Planning Board 2
August 18, 2015
Mr. Wertis MADE the MOTION to increase the draft zoning (W 71maximum allowable height
for minor ground -mounted solar arrays from 15 to 20 feet, and Mr. Blake SECONDED the
MOTION.
Discussion - Asked by Mr. Wertis for her comments, Ms. Kemp said occasionally property
owners with ground -mounted systems prefer a taller system to allow better access for lawn
maintenance. There are certain situations where having a taller system would be important, she
said. Ms. Kemp felt there ought to be some height -limit flexibility with ground -mounted systems
if 32 feet is the maximum on homes.
Mr. Salino said a 20 -feet maximum height was reasonable. Mr. Diaz agreed, adding he was
unclear as to how Geneva arrived at the 15 feet height maximum in their law.
The vote was as follows:
Mr. Wertis AYE
Ms. Adams AYE
Mr. Blake AYE
Mr. Diaz AYE
Mr. Salino AYE
Result: Motion approved.
Mr. Wertis MADE the MOTION to increase the draft zoning (W 71maximum allowable height
for major ground -mounted solar arrays from 15 to 20 feet, and Mr. Blake SECONDED the
MOTION.
The vote was as follows:
Mr. Wertis AYE
Ms. Adams AYE
Mr. Blake AYE
Mr. Diaz AYE
Mr. Salino AYE
Result: Motion approved.
A discussion ensued about whether or not the Lakeshore District would be permitted to have
major ground -mounted solar installations. Ms. Kiley explained the lakeshore typography does
not accommodate major installations, largely since the land does not slope in a direction that is
appropriate, and most lots are not large enough. Plus, much of the Lakeshore District is within
Unique Natural Areas, and the Town does not want to endorse the removal of trees to
accommodate ground -mounted solar arrays.
Ms. Adams asked about prohibiting ground -mounted solar in the Conservation Zone. Ms. Kiley
said the Conservation Zone includes much land that is flat, located at higher elevations, and thus
Planning Board 3
August 18, 2015
better for ground -mounted solar. What difference does it make, Mr. Wertis asked, if the Town
excludes major projects in the Lakeshore District; the land cannot accommodate it anyway. Mr.
Diaz said the Town ought to exclude major ground -mounted solar projects from the Lakeshore
because the area is susceptible to erosion, and a 4,000 -square foot installation would have a
major impact on the land.
Mr. Wertis asked about excluding the Hamlet of Jacksonville from major ground -mounted solar
arrays. Ms. Kiley said the intention for the hamlet is to incorporate dense residential and business
uses, making it a walkable community. With those goals in mind, a half -acre solar installation
would be a tougher sell in the Hamlet. Does that limit the option for community solar, Ms. Kiley
asked. Ms. Kemp clarified that community solar does not require that a ground -mounted solar
installation be located directly near user properties.
Mr. Wertis MADE the MOTION to include language within the draft law that would prohibit
major solar systems in the Lakeshore District, and Ms. Adams SECONDED the MOTION.
The vote was as follows:
Mr. Wertis AYE
Ms. Adams AYE
Mr. Blake NAY
Mr. Diaz AYE
Mr. Salino AYE
Result: Language approved.
Mr. Wertis MADE the MOTION to include language within the draft law that would prohibit
major solar systems in the Hamlet District, and Mr. Diaz SECONDED the MOTION.
Ms. Adams said it seemed to her that Jacksonville could have the room for a major solar
installation that complies with setback requirements and is located away from Route 96. Mr.
Blake noted land owned by Exxon -Mobil could, in the future, accommodate a major solar project
if buildings were razed.
The vote was as follows:
Mr. Wertis NAY
Ms. Adams NAY
Mr. Blake NAY
Mr. Diaz NAY
Mr. Salino NAY
Result: Motion failed.
7I4 -IID LW H3MIRLP LRLEQB motions near
inhabited structures. Mr. Diaz said, at present, minor installations would have to comply with the
Planning Board 4
August 18, 2015
25 -feet setback requirement, though 25 feet from a house would still be a significant impact. He
suggested the minimum setback requirements for ground -mounted installations align with the
50 -feet figure for front -yard setbacks, if the array is located near inhabited structures. If no
inhabited structures were located in the vicinity, the setback requirements would revert to the
minimum 25 feet for rear- and side -yards.
Mr. Blake MADE the MOTION to establish that ground -mounted solar installations must be at
least 50 feet from neighboring inhabited structures, and Mr. Wertis SECONDED the MOTION.
The vote was as follows:
Mr. Wertis AYE
Ms. Adams AYE
Mr. Blake AYE
Mr. Diaz AYE
Mr. Salino AYE
Result: Motion approved.
A conversation ensued on front yard setbacks and Site Plan Review for minor installations. Ms.
Kiley said some Town property owners have large front yards, with homes set 200 feet back
from the road. That entire space would be considered a front yard. She did not see the Planning
F1RELGTUTB3WJ RIKREJ K6 BW G" FMLY & ICI&ff)VUFFI<EISIFHDDKFDMtECRO-EI
project.
With the Board on the subject of front yard installations, Mr. Wertis asked if there were any
specific standards that the Planning Board should add into Site Plan Review for solar. For Site
Plan Review of front yard installations, Ms. Kiley said the Planning Board would be examining
the existing lot and agreeing that no other place could accommodate ground -mounted solar.
Would there be an instance when the Planning Board would turn down an applicant who has
proposed ground -mounted solar in their front yard? Mr. Diaz asked. Ms. Adams said guidelines
exist, but the Board does not have them currently. She said she could find those guidelines for
)XHfflFELCLELfflEW HUD ❑
The Board discussed its current membership, since Ms. Adams and Mr. Salino have resigned
effective the next meeting. It was suggested that 0 =(P FH4 J 3R❑
continue the solar regulations discussion, while Mr. Salino will be replaced by Rebecca
Schneider at )KHE FH4 J LLD Ulf HM❑ICJ J B[3kE3KHE]
current draft law and instead review standards at the next meeting.
Mr. Diaz proposed including prime soils among the areas of potential sensitivity to be considered
in Site Plan Review for major installations. He is concerned with large ground -mounted arrays
occupying land with good soils. Ms. Adams reiterated her concern that the Conservation District
should be excluded from permitted areas for major installations. Mr. Diaz noted the Town
LRP SU44L M aVELEIJJ HWISKIGLIIWaw seems in
conflict with the Comprehensive Plan on the subject of the Conservation Zone, he said, adding
Planning Board 5
August 18, 2015
that requiring major installations to go through Site Plan Review establishes a high level of
scrutiny.
The Planning Board briefly discussed vegetative screening for ground -mounted solar arrays. Ms.
Adams said some laws state specific height requirements for vegetative screening. Mr. Diaz said
screening is indicated within the draft law, but specifics are not mentioned, and that is a concern.
Ms. Kemp pointed the Planning Board to its meaning of the lot coverage percentage. She asked
if the 50 -percent lot coverage limit is based on the solar panel material itself or the rectangular
footprint of the entire installation. The difference between the two is huge, she said. For ground -
mounted solar projects, approximately 1/3 covers the ground and the remaining 2/3 is open space
between arrays to prevent shading. Basing the coverage area on the combined footprint of the
ground cover and open space would require much bigger parcels, she said.
Ms. Adams said the 4,000 square -foot figure pertained to total lot coverage. Mr. Diaz said he
ZD7RVFFP S0MDJF0EUREAWHXTEHT9EFHN9MRZ MEOFFUMEbw refers to the 4,000
square -feet maximum not in terms of total lot coverage but in the combined square footage of the
solar collectors. Ms. Adams said measuring the footprint by total lot coverage is easier to
calculate. Mr. Diaz thought the 4,000 square feet of solar collectors seemed like a weird
loophole, with the potential for larger impact. Mr. Wertis asked why the concern with lot
coverage of major installations when such solar projects will likely go on rural land surrounded
by hedgerows? Ms. Kemp said land procurement is not a trivial thing; the ideal spots to connect
to the grid are not plentiful. A variance could handle the issue, Ms. Adams said. She reiterated
that measuring the perimeter of the entire installation could still be utilized, with the total lot
coverage requirement increased. She asked Ms. Kemp if the 50 -percent total lot coverage
proposed in the draft law is an issue. Ms. Kemp said the figure would be perfect, if it measures
solar generators.
Mr. Diaz asked about total lot coverage for minor installations. Ms. Kiley said the lot coverage is
4,000 square feet of solar collectors, and she read the law that states: When combined with all
other buildings and structures on the lot, the total surface area shall not exceed the maximum lot
coverage for the zoning district plus 10 percent. Mr. Diaz calculated that the language could
allow a much larger footprint. Mr. Blake suggested minor installations not exceed 2,000 square
feet.
Mr. Blake MADE the MOTION to establish a coverage limit for minor installations of 2,000
square feet of solar panels and related equipment. Furthermore, any project exceeding 2,000
square feet would be considered a major installation and reviewable under Site Plan Review. Mr.
Wertis SECONDED the MOTION.
The vote was as follows:
Mr. Wertis AYE
Ms. Adams AYE
Mr. Blake AYE
Mr. Diaz AYE
Planning Board 6
August 18, 2015
Mr. Salino ABSTAINED
Result: Motion approved
Mr. Salino said he was unsure whether to vote yes or no. His formal vote was never officially
cast because the Planning Board continued its debate of the law. The Board reached a consensus
that any project under 2,000 square feet is considered minor and does not require Site Plan
Review, while projects between 2,000 and 4,000 square feet are subject to Site Plan Review.
Town Liaison Report: Mr. Goldman said the Town has begun its budget process for 2016.
Agenda Items for 9/1/2015: Ms. Kiley said the Lupo Preliminary Plat did not go through any
P ERI KD -J ISIRTKU OTL-J 171RaGTAWMMHZ EJMIIDRD WE
Lupo development, they should raise them as soon as possible, Mr. Wertis said.
Mr. Salino MADE the MOTION to adjourn the meeting, and Mr. Blake SECONDED the
MOTION.
Meeting adjourned at 8:44 p.m.