Loading...
HomeMy WebLinkAboutI - 07a GLSC Playground - FULL InspectionMain Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY AREA REPORT Gutchess Lumber Sports Complex Playground AGE SEPARATION : Playgrounds intended to serve children of all ages should show distinct areas for the different age groups. (CPSC 2.2.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAYGROUND Gutchess Lumber Sports Complex Playground Younger children (2-5) have separate areas with appropriately sized equipment and does not contain: - chain or cable walks - log rolls - freestanding arch climbers - spiral slides > 360 degrees - freestanding events with flexible components - overhead rings - parallel bars - fulcrum seesaws - track rides - swinging gates - sliding poles (CPSC 2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground EQUIPMENT LOCATION : Bare or painted metal surfaces on platforms and slide beds should be avoided unless they can be located out of direct sun. Platforms may be wood, plastic or vinyl coated & slide beds may be plastic. (CPSC 2.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Moving equipment is located toward a corner, side or edge of the play area. (CPSC 2.2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground ITEMS NOT RECOMMENDED FOR PUBLIC PLAYGROUNDS : No Animal Figure Swings. (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No Exercise Rings and Trapeze Bars. (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No Multiple Occupancy Swings (excluding tire swings). (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground No Rope Swings. (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No Swinging Gates (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No Trampolines. (CPSC 12.7) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground LEAD PAINT : The play area is free from lead paint (maximum 0.06% lead by dry weight – ref. CPSC 8.1). If playground was constructed prior to 1980 a sample of the paint will be taken and tested. (CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE MANUFACTURER IDENTIFICATION : The manufacturer’s/designer’s name is attached to equipment. (ASTM 15.1, ASTM 15.2, ASTM 12) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground OVERHEAD OBSTRUCTIONS : Overhead obstructions within the use zones of playground equipment that are not part of the play structure (i.e. tree limbs) shall not be within 84” of each designated play surface, the use zone, or above the pivot point of swings. (ASTM 9.8.4.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SIGNS OR LABELS, OR BOTH : Signs or labels providing the following information: The age appropriateness of users. Supervision is recommended. Hot play surfaces. Hazard of play equipment located over hard surfaces. Removal of helmets, drawstrings, or accessories around the neck. (ASTM 14.2.1, CPSC 2.2.6, ASTM 14.2.3, ASTM 14.2.4, ASTM 14.2.2, ASTM 14.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground Signs/labels may be placed directly on the equipment or freestanding. Freestanding signs shall be located outside the equipment use zone. (ASTM 14.1.2, ASTM 14.1, ASTM 14.1.3, CPSC 2.2.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SITE SELECTION : No hazards or obstacles to children traveling to or from the playground. (CPSC 2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground There are barriers to nearby streets or hazards. (CPSC 2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE TRIPPING HAZARDS : Barriers between equipment or for containment of surfacing materials are installed so as not to create a trip hazard and are free of protrusions, splinters, sharp edges, etc. and are outside equipment use zone. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 96/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground Change in elevation should be obvious to user. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 106/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE Netplex Structre CRUSH/SHEAR : There should be no accessible crush or shear points on playground equipment. Such points can be caused by components moving relative to each other or to a fixed component when the equipment moves through its anticipated use cycle. (CPSC 3.1, ASTM 6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTANGLEMENT : Connecting Devices - 'S' hooks and 'C' hooks must be closed as per ASTM Figure A1.19. (ASTM Figure A1.19, CPSC 5.3.8.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE Netplex Structre Exposed Bolt Ends - two thread rules as per ASTM Figure A1.15(6). (ASTM Figure A1.15(6), CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Projections from a Horizontal Plane - a projection meeting ASTM 6.4.1.1 and projecting upwards from the horizontal is an entanglement hazard, as per ASTM Figures A1.15 through A1.17. (ASTM Figure A1.15, ASTM Figure A1.16, ASTM Figure A1.17, ASTM 6.4.1.1, CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Projections which increase in size - any projection that increases in size or diameter from its initial surface is an entanglement hazard as per ASTM Figure A1.15(7) and A1.16. (ASTM Figure A1.16, ASTM Figure A1.15(7), CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE Netplex Structre Slides - test as per ASTM Figure A1.14 through A1.17 and A1.23. (ASTM Figure A1.14, ASTM Figure A1.15, ASTM Figure A1.16, ASTM Figure A1.17, ASTM Figure A1.23, CPSC B.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTRAPMENT : COMPLETELY BOUNDED OPENING : Test with head and torso probes as per CPSC Appendix B. (CPSC Appendix B.2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTRAPMENT : PARTIALLY BOUNDED OPENING : Test with "fish" probe as per ASTM drawings A1.4 through A1.9. (ASTM Figure A1.4, ASTM Figure A1.5, ASTM Figure A1.6, ASTM Figure A1.7, ASTM Figure A1.8, ASTM Figure A1.9, CPSC b.2.5.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE Netplex Structre FASTENERS/HARDWARE : All fasteners and hardware are tight, showing no loose play or excessive wear. (CPSC 2.5.2, ASTM 4.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE All fasteners, connecting, and covering devices shall be inherently corrosion-resistant or be provided with a corrosion-resistant coating. (ASTM 4.2.1, CPSC 2.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Steel cable that is permanently affixed to a hanger should be inaccessible or capped to prevent access to frayed wires. Cables & steel cored ropes should be protected to prevent fraying, loosening, unraveling, or excessive shifting. (ASTM 4.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE Netplex Structre GUARDRAILS - COMPOSITE STRUCTURE : Bottom of guardrail to be NO more than 28" H on lower edge. (CPSC 5.1.3, ASTM 7.5.5.4, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Guardrails shall completely surround the elevated surfaces except for entrance and exit openings necessary for each event. (ASTM 7.5.5.2, CPSC 5.1.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms elevated more than 30" above protective surfacing must have guardrails. (CPSC 5.1.3, ASTM 7.5.5.1, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE Netplex Structre Top of guardrail to be 38". (CPSC 5.1.3, ASTM 7.5.5.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE BARRIERS - COMPOSITE STRUCTURE : Openings within barriers or between the platform and lower edge of barrier shall be less than 3-1/2". (CPSC 3.3.1, CPSC Table 4, ASTM 7.5.6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Protective barriers shall completely surround the elevated surface except for entrance and exit openings necessary for each event. (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE Netplex Structre There is a 38” high (minimum) protective perimeter barrier on all elevated surfaces 48” above the underlying surface for 5-12 year olds. (ASTM 7.5.6.1, CPSC 5.1.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Top of barrier to be 38”, minimum. (CPSC 5.1.3, ASTM 7.5.6.4, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE SURFACING : Depth of the protective surfacing material correct for the critical height of the equipment. (ASTM F1292, CPSC 2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE Netplex Structre PROTRUSIONS : Test all accessible projections with the three gauges as per ASTM Figures A1.10 through A1.13. (ASTM Figure A1.10, ASTM Figure A1.11, ASTM Figure A1.12, ASTM Figure A1.13, CPSC B.2.1, CPSC B2.2.2, CPSC B.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ROOF HEIGHT : Roofs that are an integral part of a play structure may be any angle, provided that the roof line (lowest edge), excluding support members, is at least 84" above the underlying designated play surface. (ASTM 8.14.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Support members shall be designed to discourage climbing and have no designated play surfaces. (ASTM 8.14.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 PLAY STRUCTURE Netplex Structre SHARP POINTS, CORNERS AND EDGES : A cut-off bolt end projecting beyond the face of the nut shall be free of burrs, sharp points and sharp edges. (ASTM 6.2.4, CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Exposed open ends of all tubing not resting on the ground or otherwise covered should be covered by caps or plugs that cannot be removed without the use of tools. (CPSC 3.4, ASTM 6.2.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No sharp points, corners or edges. (ASTM 6.2, CPSC 3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 96/9/2021 PLAY STRUCTURE Netplex Structre STEPPED PLATFORMS : Distance between stepped platforms for 5-12 yr olds is NO more than 18". (CPSC 5.1.2, ASTM 7.5.7.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE - COMPOSITE STRUCTURE : Equipment is free of corrosion/rust and chipping paint. (CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 106/9/2021 PLAY STRUCTURE Netplex Structre Platforms shall be horizontal within + or - 2 degrees. (ASTM 7.5.1, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms shall not trap water and not accumulate debris. (ASTM 7.5.2, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SUSPENDED HAZARDS : Cables, wires, ropes, or similar flexible components suspended between play units or from the ground to a play unit within 45" of horizontal and is a minimum of 1" at its widest cross section dimension, should not be located in areas of high traffic. (ASTM 6.6, CPSC 3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 116/9/2021 PLAY STRUCTURE Netplex Structre Suspended members should be brightly colored or contrast with surrounding equipment to add o their visibility. (ASTM 6.6.2, CPSC 3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE - COMPOSITE STRUCTURE : Slide use zones shall be a minimum of 6' and equal to the height of the slide up to 8' maximum. (CPSC 5.3.6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There is a minimum use zone of 6’ in all directions for all equipment. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 126/9/2021 PLAY STRUCTURE Netplex Structre Use zones for adjacent pieces of play equipment may overlap if the adjacent designated play stationary surfaces are less than 30” above the protective surfacing (6’ apart). If either adjacent structure exceeds 30”, the minimum distance between the stationary structures should be 9’. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 136/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Double Swoosh Slide CLEARANCE : A clear area, free of equipment, shall surround the slide chute that is 21” wide from the inside edge of slide rail including transition platform, and 60” tall. The clear area shall extend through the slide exit clearance zone. (ASTM 8.5.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE EXIT REGION : Flat sliding surface at the bottom of the slide is a minimum of 11” long at the bottom of the transition point and angle is less than 5º from the horizontal plane. (CPSC 5.3.6.4, ASTM 8.5.5.1, ASTM 8.5.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Double Swoosh Slide For slides greater than 4’ high, the slide exit height is between 7” and 15” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Radius of curvature of the sliding surface in the exit region shall be 30” or greater. (ASTM 8.5.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide exit edges shall be rounded or curved. (ASTM 8.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Slides 4’ high, or less, the slide exit height does not exceed 11” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slides have exit region length of 11” of greater. (CPSC 5.3.6.4, ASTM 8.5.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SLIDE CHUTE : Handrails or other means of hand support shall be provided at the slide chute entrance to channel user from standing to sitting. (CPSC 5.3.6.2, ASTM 8.5.3.1, ASTM 8.5.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Height/length ratio of the sliding surface shall not exceed 0.577 (30º) (height of slide divided by length of slide). (ASTM 8.5.4.1, CPSC 5.3.6.3.4, CPSC Figure 20) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Inside width shall be 16” or greater for 5-12 year olds. (ASTM 8.5.4.3, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum slope, on any part, of the sliding surface is not more than 50º. (ASTM 8.5.4.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Side walls are 4” high on straight slide with open chutes that extends entire length of slide. (ASTM 8.5.4.4, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If the slide is made in several pieces, the sliding surface has no gaps or rough edges at the top of the slide or at section seams which could entangle or trap foreign material. (CPSC 5.3.6.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE TRANSITION PLATFORM : It is recommended that the platform have a minimum length of 14 inches. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No spaces or gaps between the platforms and the start of the slide chute. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Slide transition platform must be at least as wide as the slide top entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There are sufficient safety barriers at the top of the slide to prevent falls, with hand holds to assist standing to sitting transition and a means to channel the user to the sitting position before slide entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : For slides less than or equal to 6 feet high the use zone in front of the exit should be 6 feet. And for slides greater than 6 feet the use zone in front of the exit should be at least as long as the slide is high up to a maximum of 8 feet. (CPSC 5.3.6.5, ASTM 9.6.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide The Use Zone extends a minimum of 6’ in all directions from the perimeter of the equipment, including the slide exit if slide is less than or equal to 72” high. (CPSC 5.3.6.5, ASTM 9) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Lolliladder HANDGRIPS : For any flexible elements (chain, cable, ‘S’ hooks, etc.), used to suspend the ring /rung, it shall be no longer than 7”. (ASTM 8.3.5, CPSC 5.3.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE For moveable hanging rings and rungs, the distance between uppermost pivot and bottom of hand-grip shall be no greater than 15”. (ASTM 8.3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Lolliladder STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum center-to-center distance between rungs for overhead equipment is no more than 15” for 5-12 year olds and the openings pass the entrapment test. (CPSC 5.3.2.4, ASTM 8.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum height from center of rung to surfacing is 84” for 5-12 year olds and 54” for wheelchair users. (CPSC 5.3.2.4, ASTM 8.3.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Lolliladder Maximum height of the take-off/landing structure for upper body equipment is less than or equal to 36” for 5-12 year olds. (CPSC 5.3.2.4, ASTM 8.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The horizontal distance from the leading edge of the takeoff or landing structure, or both, out to the first handhold of upper body equipment shall be no greater than 10”. (CPSC 5.3.2.4, ASTM 8.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Lolliladder Where the takeoff or landing point is provided by means of rungs, horizontal distance to the first handhold shall be at least 8”, no greater than 10”. (CPSC 5.3.2.4, ASTM 8.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Loop Ladder ACCESS : Climbers used as access has provided a means of hand support for the use while climbing. (ASTM 7.3.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE For Rung Ladders, flexible components, and arch climbers the stepping surface shall not be above the designated play surface it serves. (ASTM 7.4.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If arch climbers and flexible components are used, they are not the sole means of access to other components of equipment. (CPSC 5.3.2.2, ASTM 7.3.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Loop Ladder HANDGRIPS : Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No bars on the interior of the structure onto which a child may fall from a height of 18” of greater. (CPSC 5.3.2.1.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Loop Ladder Rigid rungs used for hand support during ascent and descent shall be between 0.95” – 1.55” in diameter and shall not twist/rotate on its own axis. (CPSC 5.2.2, ASTM 8.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rope, Chain, or cable with a length of 7.0 inches or less may be attached at one end only. (CPSC 3.5, ASTM 6.6.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Loop Ladder The maximum horizontal opening on access point of deck to be no more than 15” (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : Minimum use zone of 6’ in all directions, unless part of the composite structure. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The use zone of stationary equipment and other equipment may overlap. If the distance of the designated play surfaces are less than 30" it can be a minimum of 72". If the height is greater than 30" than the minimum shall be 108". (CPSC 5.3.2.1.4, ASTM 9.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Netplex Climber FLEXIBLE CLIMBING COMPONENT : Climbing ropes are secure at both ends and not capable of being looped back on itself creating a loop with an inside perimeter greater than 5". (CPSC 3.5, ASTM 6.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Ropes, chains, and cables have not frayed or worn out. (CPSC 4.0) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Netplex Climber HANDGRIPS : Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE BARRIERS : Protective barriers at the top of the platform entrance/exit opening, has a maximum opening of 15”. (CPSC 5.3.2.6, ASTM 8.4.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Netplex Climber STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Mesh structure shall be arranged in a manner so there is no clear opening between flexible members with a vertical dimension greater than 72" and a diameter greater than 20" for climbing nets for 5-12 year olds. (ASTM 8.2.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rope, Chain, or cable with a length of 7.0 inches or less may be attached at one end only. (CPSC 3.5, ASTM 6.6.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Netplex Climber Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible HANDRAIL : Wheelchair accessible ramps less than or equal to 48” above protective surfacing, when designed for 5-12 year olds, shall have two handrails on each side of the ramp that are 26” – 28” high and 12” – 16” high. (ASTM 7.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE BARRIERS : Protective barriers are required on ramp greater than 48” high for 5-12 year olds, and shall have handrails 26” – 28” high on both sides of the ramp. (ASTM 7.5.6.1, ASTM 7.5.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible Wheelchair accessible ramps must have a curb projecting above the ramp a minimum of 2” at both edges when any of the following conditions are present: (1)guardrails or barriers not extending to within 1” of the ramp surface (2)ramps with two rails and no barriers, or (3)ramps where the barrier is beyond the edge of the ramp surface (ASTM 7.5.5.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible Landings with play components shall have a wheelchair parking space, 30” x 48”, which does not reduce the circulation path to less than 36”. (ASTM 7.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Ramps for wheelchair access shall not exceed a horizontal run of 144” (12’). (ASTM 7.2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Ramps shall not trap water and should not encourage accumulation of debris. (ASTM 7.5.2, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible Ramps that are elevated above the protective surfacing and that are accessible to wheelchairs shall provide a clear width of not less than 36”. Clear width may be reduced to 32” for not more than 24” along the path of travel. (ASTM 7.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Ramps, platforms or stationary bridges used for elevated access are exempt from the use zone requirements at the entry area. (ASTM 7.1.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible TRANSFER POINTS : Transfer points have wheelchair turning space at base of transfer point; a clear space area of 60” min. T-shaped area in accordance with ASTM Figure A1.47. (ASTM Figure A1.47) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Rollerslide CLEARANCE : A clear area, free of equipment, shall surround the slide chute that is 21” wide from the inside edge of slide rail including transition platform, and 60” tall. The clear area shall extend through the slide exit clearance zone. (ASTM 8.5.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE EXIT REGION : Flat sliding surface at the bottom of the slide is a minimum of 11” long at the bottom of the transition point and angle is less than 5º from the horizontal plane. (CPSC 5.3.6.4, ASTM 8.5.5.1, ASTM 8.5.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Rollerslide For slides greater than 4’ high, the slide exit height is between 7” and 15” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Radius of curvature of the sliding surface in the exit region shall be 30” or greater. (ASTM 8.5.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide exit edges shall be rounded or curved. (ASTM 8.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Rollerslide Slides 4’ high, or less, the slide exit height does not exceed 11” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slides have exit region length of 11” of greater. (CPSC 5.3.6.4, ASTM 8.5.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ROLLER SLIDE : Space between adjacent rollers does not allows a 3/16” rod to enter, either between rollers or adjacent stationary segments. (ASTM 8.9.2.1, CPSC 5.3.6.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Rollerslide There shall be no crush, shear, entrapment, entanglement or catch points between the junctures caused by two of more components. (ASTM 8.9.2, CPSC 5.3.6.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SLIDE CHUTE : Handrails or other means of hand support shall be provided at the slide chute entrance to channel user from standing to sitting. (CPSC 5.3.6.2, ASTM 8.5.3.1, ASTM 8.5.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Height/length ratio of the sliding surface shall not exceed 0.577 (30º) (height of slide divided by length of slide). (ASTM 8.5.4.1, CPSC 5.3.6.3.4, CPSC Figure 20) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Rollerslide Inside width shall be 16” or greater for 5-12 year olds. (ASTM 8.5.4.3, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum slope, on any part, of the sliding surface is not more than 50º. (ASTM 8.5.4.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Side walls are 4” high on straight slide with open chutes that extends entire length of slide. (ASTM 8.5.4.4, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE COMPONENT Rollerslide STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If the slide is made in several pieces, the sliding surface has no gaps or rough edges at the top of the slide or at section seams which could entangle or trap foreign material. (CPSC 5.3.6.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE COMPONENT Rollerslide TRANSITION PLATFORM : It is recommended that the platform have a minimum length of 14 inches. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No spaces or gaps between the platforms and the start of the slide chute. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide transition platform must be at least as wide as the slide top entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE COMPONENT Rollerslide There are sufficient safety barriers at the top of the slide to prevent falls, with hand holds to assist standing to sitting transition and a means to channel the user to the sitting position before slide entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : For slides less than or equal to 6 feet high the use zone in front of the exit should be 6 feet. And for slides greater than 6 feet the use zone in front of the exit should be at least as long as the slide is high up to a maximum of 8 feet. (CPSC 5.3.6.5, ASTM 9.6.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The Use Zone extends a minimum of 6’ in all directions from the perimeter of the equipment, including the slide exit if slide is less than or equal to 72” high. (CPSC 5.3.6.5, ASTM 9) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Sol Spinner CLEARANCE : Rotating equipment shall have a 72" clearance zone free of rigid structural components. Measured from the edge of the rotating component. (ASTM 8.8.1.10) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The clearance between the bottom edge of the equipment and the surfacing should be between 2.38 and 3.5 inches. Or greater than 9.0 Inches (ASTM 8.8.1.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Sol Spinner HANDGRIPS : Hand-grips shall be provided to help children maintain their balance, or the platform where the children sit shall be dish- or tub-like. (ASTM 8.8.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Merry-go-round platforms shall not be provided with an up and down motion. (CPSC 5.3.4, ASTM 8.8.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Sol Spinner Merry-go-rounds shall be constructed to limit their maximum speed to 13 ft/sec. Merry-go-rounds with platform diameters less than 20” is exempt from the speed limitations. (CPSC 5.3.4, ASTM 8.8.6, ASTM 8.8.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No components, including hand-grips, should extend beyond the perimeter of the platform. (CPSC 5.3.4, ASTM 8.8.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rotating platform should be continuous and approximately circular. Difference between minimum and maximum radii of a noncircular platform should not exceed 2”. (CPSC 5.3.4, ASTM 8.8.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Sol Spinner Standing surface shall have a minimum height of 9” and maximum height of 18” above the protective surface when designed for 5-12 year olds. (CPSC 5.3.4, ASTM 8.8.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : Minimum use zone of 6’ in all directions, unless part of the composite structure. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Sol Spinner The use zone extends a minimum of 6’ in all directions from the perimeter of the equipment. (ASTM 9.3.1, CPSC 5.3.4.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The use zone of a spinner with a diameter greater than 20 inches and with a speed limiter is a minimum of 72 inches. It shall not overlap with other use zones. (ASTM 9.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Stepping Pod STEPPING FORMS : Any stepping form greater than 30" tall shall be stationary. (ASTM 8.15.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping form hand supports shall be required at the beginning of pods that are higher than 30" for 5-12 year olds. The hand support height shall be between 22" - 38". (ASTM 8.15.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Stepping Pod Stepping forms shall be no greater than 18" apart when intended for 5 -12 year olds. Dimensions are measured edge to edge between the adjacent stepping surfaces (measurement is horizontal), when forms are at the same height. If stepping forms are at different heights the measurement is at a diagonal. (ASTM 8.15.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms shall be no greater than 30" when used for 5-12, unless hand support is provided. (ASTM 8.15.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms shall contain a minimum designated play surface of 10” in diameter with a slope no greater than 30º from horizontal. (ASTM 8.15.1, ASTM 8.15.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Tree Climber ACCESS : Climbers used as access has provided a means of hand support for the use while climbing. (ASTM 7.3.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE For Rung Ladders, flexible components, and arch climbers the stepping surface shall not be above the designated play surface it serves. (ASTM 7.4.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If arch climbers and flexible components are used, they are not the sole means of access to other components of equipment. (CPSC 5.3.2.2, ASTM 7.3.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Tree Climber HANDGRIPS : Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No bars on the interior of the structure onto which a child may fall from a height of 18” of greater. (CPSC 5.3.2.1.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Tree Climber Rigid rungs used for hand support during ascent and descent shall be between 0.95” – 1.55” in diameter and shall not twist/rotate on its own axis. (CPSC 5.2.2, ASTM 8.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rope, Chain, or cable with a length of 7.0 inches or less may be attached at one end only. (CPSC 3.5, ASTM 6.6.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Tree Climber The maximum horizontal opening on access point of deck to be no more than 15” (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : Minimum use zone of 6’ in all directions, unless part of the composite structure. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The use zone of stationary equipment and other equipment may overlap. If the distance of the designated play surfaces are less than 30" it can be a minimum of 72". If the height is greater than 30" than the minimum shall be 108". (CPSC 5.3.2.1.4, ASTM 9.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE Playshaper Structre CRUSH/SHEAR : There should be no accessible crush or shear points on playground equipment. Such points can be caused by components moving relative to each other or to a fixed component when the equipment moves through its anticipated use cycle. (CPSC 3.1, ASTM 6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTANGLEMENT : Connecting Devices - 'S' hooks and 'C' hooks must be closed as per ASTM Figure A1.19. (ASTM Figure A1.19, CPSC 5.3.8.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE Playshaper Structre Exposed Bolt Ends - two thread rules as per ASTM Figure A1.15(6). (ASTM Figure A1.15(6), CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Projections from a Horizontal Plane - a projection meeting ASTM 6.4.1.1 and projecting upwards from the horizontal is an entanglement hazard, as per ASTM Figures A1.15 through A1.17. (ASTM Figure A1.15, ASTM Figure A1.16, ASTM Figure A1.17, ASTM 6.4.1.1, CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Projections which increase in size - any projection that increases in size or diameter from its initial surface is an entanglement hazard as per ASTM Figure A1.15(7) and A1.16. (ASTM Figure A1.16, ASTM Figure A1.15(7), CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE Playshaper Structre Slides - test as per ASTM Figure A1.14 through A1.17 and A1.23. (ASTM Figure A1.14, ASTM Figure A1.15, ASTM Figure A1.16, ASTM Figure A1.17, ASTM Figure A1.23, CPSC B.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTRAPMENT : COMPLETELY BOUNDED OPENING : Test with head and torso probes as per CPSC Appendix B. (CPSC Appendix B.2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTRAPMENT : PARTIALLY BOUNDED OPENING : Test with "fish" probe as per ASTM drawings A1.4 through A1.9. (ASTM Figure A1.4, ASTM Figure A1.5, ASTM Figure A1.6, ASTM Figure A1.7, ASTM Figure A1.8, ASTM Figure A1.9, CPSC b.2.5.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE Playshaper Structre FASTENERS/HARDWARE : All fasteners and hardware are tight, showing no loose play or excessive wear. (CPSC 2.5.2, ASTM 4.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE All fasteners, connecting, and covering devices shall be inherently corrosion-resistant or be provided with a corrosion-resistant coating. (ASTM 4.2.1, CPSC 2.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Steel cable that is permanently affixed to a hanger should be inaccessible or capped to prevent access to frayed wires. Cables & steel cored ropes should be protected to prevent fraying, loosening, unraveling, or excessive shifting. (ASTM 4.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE Playshaper Structre GUARDRAILS - COMPOSITE STRUCTURE : Bottom of guardrail to be NO more than 23" above the platform. (CPSC 5.1.3, ASTM 7.5.5.4, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Guardrails shall completely surround the elevated surfaces except for entrance and exit openings necessary for each event. (ASTM 7.5.5.2, CPSC 5.1.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms elevated more than 20" above protective surfacing must have guardrails. (CPSC 5.1.3, ASTM 7.5.5.1, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE Playshaper Structre Top of guardrail to be 29". (CPSC 5.1.3, ASTM 7.5.5.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE BARRIERS - COMPOSITE STRUCTURE : Openings within barriers or between the platform and lower edge of barrier shall be less than 3-1/2". (CPSC 3.3.1, CPSC Table 4, ASTM 7.5.6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms elevated more than 30" above protective surfacing must have protective barriers. (ASTM 7.5.6.1, CPSC 5.1.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE Playshaper Structre Protective barriers shall completely surround the elevated surface except for entrance and exit openings necessary for each event. (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Top of barrier to be 29". (CPSC 5.1.3, ASTM 7.5.6.4, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE SURFACING : Depth of the protective surfacing material correct for the critical height of the equipment. (ASTM F1292, CPSC 2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE Playshaper Structre PROTRUSIONS : Test all accessible projections with the three gauges as per ASTM Figures A1.10 through A1.13. (ASTM Figure A1.10, ASTM Figure A1.11, ASTM Figure A1.12, ASTM Figure A1.13, CPSC B.2.1, CPSC B2.2.2, CPSC B.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ROOF HEIGHT : Roofs that are an integral part of a play structure may be any angle, provided that the roof line (lowest edge), excluding support members, is at least 84" above the underlying designated play surface. (ASTM 8.14.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Support members shall be designed to discourage climbing and have no designated play surfaces. (ASTM 8.14.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 PLAY STRUCTURE Playshaper Structre SHARP POINTS, CORNERS AND EDGES : A cut-off bolt end projecting beyond the face of the nut shall be free of burrs, sharp points and sharp edges. (ASTM 6.2.4, CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Exposed open ends of all tubing not resting on the ground or otherwise covered should be covered by caps or plugs that cannot be removed without the use of tools. (CPSC 3.4, ASTM 6.2.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No sharp points, corners or edges. (ASTM 6.2, CPSC 3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 96/9/2021 PLAY STRUCTURE Playshaper Structre STEPPED PLATFORMS : Distance between stepped platforms for 2-5 yr olds is NO more than 12". (CPSC 5.1.2, ASTM 7.5.7.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE - COMPOSITE STRUCTURE : Equipment is free of corrosion/rust and chipping paint. (CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 106/9/2021 PLAY STRUCTURE Playshaper Structre Platforms shall be horizontal within + or - 2 degrees. (ASTM 7.5.1, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms shall not trap water and not accumulate debris. (ASTM 7.5.2, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SUSPENDED HAZARDS : Cables, wires, ropes, or similar flexible components suspended between play units or from the ground to a play unit within 45" of horizontal and is a minimum of 1" at its widest cross section dimension, should not be located in areas of high traffic. (ASTM 6.6, CPSC 3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 116/9/2021 PLAY STRUCTURE Playshaper Structre Suspended members should be brightly colored or contrast with surrounding equipment to add o their visibility. (ASTM 6.6.2, CPSC 3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE - COMPOSITE STRUCTURE : Slide use zones shall be a minimum of 6' and equal to the height of the slide up to 8' maximum. (CPSC 5.3.6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There is a minimum use zone of 6’ in all directions for all equipment. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 126/9/2021 PLAY STRUCTURE Playshaper Structre Use zones for adjacent pieces of play equipment may overlap if the adjacent designated play stationary surfaces are less than 30” above the protective surfacing (6’ apart). If either adjacent structure exceeds 30”, the minimum distance between the stationary structures should be 9’. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 136/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Single Slide CLEARANCE : A clear area, free of equipment, shall surround the slide chute that is 21” wide from the inside edge of slide rail including transition platform, and 60” tall. The clear area shall extend through the slide exit clearance zone. (ASTM 8.5.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE EXIT REGION : Flat sliding surface at the bottom of the slide is a minimum of 11” long at the bottom of the transition point and angle is less than 5º from the horizontal plane. (CPSC 5.3.6.4, ASTM 8.5.5.1, ASTM 8.5.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Single Slide For slides greater than 4’ high, the slide exit height is between 7” and 15” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Radius of curvature of the sliding surface in the exit region shall be 30” or greater. (ASTM 8.5.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide exit edges shall be rounded or curved. (ASTM 8.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Single Slide Slides 4’ high, or less, the slide exit height does not exceed 11” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slides have exit region length of 11” of greater. (CPSC 5.3.6.4, ASTM 8.5.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SLIDE CHUTE : Handrails or other means of hand support shall be provided at the slide chute entrance to channel user from standing to sitting. (CPSC 5.3.6.2, ASTM 8.5.3.1, ASTM 8.5.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Single Slide Height/length ratio of the sliding surface shall not exceed 0.577 (30º) (height of slide divided by length of slide). (ASTM 8.5.4.1, CPSC 5.3.6.3.4, CPSC Figure 20) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Inside width shall be 12” or greater for 2-5 year olds. (ASTM 8.5.4.3, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum slope, on any part, of the sliding surface is not more than 50º. (ASTM 8.5.4.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Single Slide Side walls are 4” high on straight slide with open chutes that extends entire length of slide. (ASTM 8.5.4.4, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If the slide is made in several pieces, the sliding surface has no gaps or rough edges at the top of the slide or at section seams which could entangle or trap foreign material. (CPSC 5.3.6.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE COMPONENT Single Slide Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE TRANSITION PLATFORM : It is recommended that the platform have a minimum length of 14 inches. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No spaces or gaps between the platforms and the start of the slide chute. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE COMPONENT Single Slide Slide transition platform must be at least as wide as the slide top entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There are sufficient safety barriers at the top of the slide to prevent falls, with hand holds to assist standing to sitting transition and a means to channel the user to the sitting position before slide entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : For slides less than or equal to 6 feet high the use zone in front of the exit should be 6 feet. And for slides greater than 6 feet the use zone in front of the exit should be at least as long as the slide is high up to a maximum of 8 feet. (CPSC 5.3.6.5, ASTM 9.6.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE COMPONENT Single Slide The Use Zone extends a minimum of 6’ in all directions from the perimeter of the equipment, including the slide exit if slide is less than or equal to 72” high. (CPSC 5.3.6.5, ASTM 9) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Slidewinder Slide CLEARANCE : A clear area, free of equipment, shall surround the slide chute that is 21” wide from the inside edge of slide rail including transition platform, and 60” tall. The clear area shall extend through the slide exit clearance zone. (ASTM 8.5.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE EXIT REGION : Flat sliding surface at the bottom of the slide is a minimum of 11” long at the bottom of the transition point and angle is less than 5º from the horizontal plane. (CPSC 5.3.6.4, ASTM 8.5.5.1, ASTM 8.5.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Slidewinder Slide For slides greater than 4’ high, the slide exit height is between 7” and 15” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Radius of curvature of the sliding surface in the exit region shall be 30” or greater. (ASTM 8.5.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide exit edges shall be rounded or curved. (ASTM 8.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Slides 4’ high, or less, the slide exit height does not exceed 11” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slides have exit region length of 11” of greater. (CPSC 5.3.6.4, ASTM 8.5.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SLIDE CHUTE : Handrails or other means of hand support shall be provided at the slide chute entrance to channel user from standing to sitting. (CPSC 5.3.6.2, ASTM 8.5.3.1, ASTM 8.5.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Height/length ratio of the sliding surface shall not exceed 0.577 (30º) (height of slide divided by length of slide). (ASTM 8.5.4.1, CPSC 5.3.6.3.4, CPSC Figure 20) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Inside width shall be 12” or greater for 2-5 year olds. (ASTM 8.5.4.3, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum slope, on any part, of the sliding surface is not more than 50º. (ASTM 8.5.4.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Side walls are 4” high on straight slide with open chutes that extends entire length of slide. (ASTM 8.5.4.4, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If the slide is made in several pieces, the sliding surface has no gaps or rough edges at the top of the slide or at section seams which could entangle or trap foreign material. (CPSC 5.3.6.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE TRANSITION PLATFORM : It is recommended that the platform have a minimum length of 14 inches. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No spaces or gaps between the platforms and the start of the slide chute. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Slide transition platform must be at least as wide as the slide top entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There are sufficient safety barriers at the top of the slide to prevent falls, with hand holds to assist standing to sitting transition and a means to channel the user to the sitting position before slide entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : For slides less than or equal to 6 feet high the use zone in front of the exit should be 6 feet. And for slides greater than 6 feet the use zone in front of the exit should be at least as long as the slide is high up to a maximum of 8 feet. (CPSC 5.3.6.5, ASTM 9.6.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide The Use Zone extends a minimum of 6’ in all directions from the perimeter of the equipment, including the slide exit if slide is less than or equal to 72” high. (CPSC 5.3.6.5, ASTM 9) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Stairway HANDRAIL : Continuous handrail from access to platform. (ASTM 7.4.1, CPSC 5.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Handrail is between 0.95” and 1.55” in diameter and does not twist/rotate on their own axis. (CPSC 5.2.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Handrail is between 22” – 26” high for 2-5 year olds. (CPSC 5.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Stairway SLOPE : Stair slope is less than 50º. (ASTM Table 2, CPSC Table 6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STEPS : Steps do not allow for accumulation of water and/or debris. (ASTM 7.2.2, CPSC 5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Tread depth, for open or closed risers, is equal to or greater than 7”. (ASTM Table 2, CPSC Table 6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Stairway Tread width is between 12” to 21” for 2-5 single access. Two-abreast ladders are not recommended for 2-5 year olds. (ASTM Table 2, CPSC Table 6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Vertical rise (tread to tread) is equal to or less than 9”. (ASTM Table 2, CPSC Table 6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Stairway Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Stepper Climber ACCESS : Climbers used as access has provided a means of hand support for the use while climbing. (ASTM 7.3.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE For Rung Ladders, flexible components, and arch climbers the stepping surface shall not be above the designated play surface it serves. (ASTM 7.4.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If arch climbers and flexible components are used, they are not the sole means of access to other components of equipment. (CPSC 5.3.2.2, ASTM 7.3.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Stepper Climber HANDGRIPS : Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No bars on the interior of the structure onto which a child may fall from a height of 18” of greater. (CPSC 5.3.2.1.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Stepper Climber Rigid rungs used for hand support during ascent and descent shall be between 0.95” – 1.55” in diameter and shall not twist/rotate on its own axis. (CPSC 5.2.2, ASTM 8.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rope, Chain, or cable with a length of 7.0 inches or less may be attached at one end only. (CPSC 3.5, ASTM 6.6.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Stepper Climber The maximum horizontal opening on access point of deck to be no more than 15” (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : Minimum use zone of 6’ in all directions, unless part of the composite structure. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The use zone of stationary equipment and other equipment may overlap. If the distance of the designated play surfaces are less than 30" it can be a minimum of 72". If the height is greater than 30" than the minimum shall be 108". (CPSC 5.3.2.1.4, ASTM 9.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Stepping Pod STEPPING FORMS : Any stepping form greater than 30" tall shall be stationary. (ASTM 8.15.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping form hand supports shall be required at the beginning of pods that are higher than 20” for 2-5 year olds. The hand support height shall be between 22” – 38”. (ASTM 8.15.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms intended for 2-5 shall be stationary. (ASTM 8.15.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Stepping Pod Stepping forms shall be no greater than 12” apart when intended for 2 -5 year olds. Dimensions are measured edge to edge between the adjacent stepping surfaces (measurement is horizontal), when forms are at the same height. If stepping forms are at different heights the measurement is at a diagonal. (ASTM 8.15.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms shall be no greater than 20” above the protective surfacing when used for 2-5 year olds, unless hand support is provided. (ASTM 8.15.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms shall contain a minimum designated play surface of 10” in diameter with a slope no greater than 30º from horizontal. (ASTM 8.15.1, ASTM 8.15.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY AREA REPORT Gutchess Lumber Sports Complex Playground AGE SEPARATION : Playgrounds intended to serve children of all ages should show distinct areas for the different age groups. (CPSC 2.2.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAYGROUND Gutchess Lumber Sports Complex Playground Younger children (2-5) have separate areas with appropriately sized equipment and does not contain: - chain or cable walks - log rolls - freestanding arch climbers - spiral slides > 360 degrees - freestanding events with flexible components - overhead rings - parallel bars - fulcrum seesaws - track rides - swinging gates - sliding poles (CPSC 2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground EQUIPMENT LOCATION : Bare or painted metal surfaces on platforms and slide beds should be avoided unless they can be located out of direct sun. Platforms may be wood, plastic or vinyl coated & slide beds may be plastic. (CPSC 2.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Moving equipment is located toward a corner, side or edge of the play area. (CPSC 2.2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground ITEMS NOT RECOMMENDED FOR PUBLIC PLAYGROUNDS : No Animal Figure Swings. (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No Exercise Rings and Trapeze Bars. (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No Multiple Occupancy Swings (excluding tire swings). (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground No Rope Swings. (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No Swinging Gates (CPSC 2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No Trampolines. (CPSC 12.7) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground LEAD PAINT : The play area is free from lead paint (maximum 0.06% lead by dry weight – ref. CPSC 8.1). If playground was constructed prior to 1980 a sample of the paint will be taken and tested. (CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE MANUFACTURER IDENTIFICATION : The manufacturer’s/designer’s name is attached to equipment. (ASTM 15.1, ASTM 15.2, ASTM 12) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground OVERHEAD OBSTRUCTIONS : Overhead obstructions within the use zones of playground equipment that are not part of the play structure (i.e. tree limbs) shall not be within 84” of each designated play surface, the use zone, or above the pivot point of swings. (ASTM 9.8.4.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SIGNS OR LABELS, OR BOTH : Signs or labels providing the following information: The age appropriateness of users. Supervision is recommended. Hot play surfaces. Hazard of play equipment located over hard surfaces. Removal of helmets, drawstrings, or accessories around the neck. (ASTM 14.2.1, CPSC 2.2.6, ASTM 14.2.3, ASTM 14.2.4, ASTM 14.2.2, ASTM 14.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground Signs/labels may be placed directly on the equipment or freestanding. Freestanding signs shall be located outside the equipment use zone. (ASTM 14.1.2, ASTM 14.1, ASTM 14.1.3, CPSC 2.2.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SITE SELECTION : No hazards or obstacles to children traveling to or from the playground. (CPSC 2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground There are barriers to nearby streets or hazards. (CPSC 2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE TRIPPING HAZARDS : Barriers between equipment or for containment of surfacing materials are installed so as not to create a trip hazard and are free of protrusions, splinters, sharp edges, etc. and are outside equipment use zone. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 96/9/2021 PLAYGROUND Gutchess Lumber Sports Complex Playground Change in elevation should be obvious to user. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 106/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE Netplex Structre CRUSH/SHEAR : There should be no accessible crush or shear points on playground equipment. Such points can be caused by components moving relative to each other or to a fixed component when the equipment moves through its anticipated use cycle. (CPSC 3.1, ASTM 6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTANGLEMENT : Connecting Devices - 'S' hooks and 'C' hooks must be closed as per ASTM Figure A1.19. (ASTM Figure A1.19, CPSC 5.3.8.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE Netplex Structre Exposed Bolt Ends - two thread rules as per ASTM Figure A1.15(6). (ASTM Figure A1.15(6), CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Projections from a Horizontal Plane - a projection meeting ASTM 6.4.1.1 and projecting upwards from the horizontal is an entanglement hazard, as per ASTM Figures A1.15 through A1.17. (ASTM Figure A1.15, ASTM Figure A1.16, ASTM Figure A1.17, ASTM 6.4.1.1, CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Projections which increase in size - any projection that increases in size or diameter from its initial surface is an entanglement hazard as per ASTM Figure A1.15(7) and A1.16. (ASTM Figure A1.16, ASTM Figure A1.15(7), CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE Netplex Structre Slides - test as per ASTM Figure A1.14 through A1.17 and A1.23. (ASTM Figure A1.14, ASTM Figure A1.15, ASTM Figure A1.16, ASTM Figure A1.17, ASTM Figure A1.23, CPSC B.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTRAPMENT : COMPLETELY BOUNDED OPENING : Test with head and torso probes as per CPSC Appendix B. (CPSC Appendix B.2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTRAPMENT : PARTIALLY BOUNDED OPENING : Test with "fish" probe as per ASTM drawings A1.4 through A1.9. (ASTM Figure A1.4, ASTM Figure A1.5, ASTM Figure A1.6, ASTM Figure A1.7, ASTM Figure A1.8, ASTM Figure A1.9, CPSC b.2.5.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE Netplex Structre FASTENERS/HARDWARE : All fasteners and hardware are tight, showing no loose play or excessive wear. (CPSC 2.5.2, ASTM 4.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE All fasteners, connecting, and covering devices shall be inherently corrosion-resistant or be provided with a corrosion-resistant coating. (ASTM 4.2.1, CPSC 2.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Steel cable that is permanently affixed to a hanger should be inaccessible or capped to prevent access to frayed wires. Cables & steel cored ropes should be protected to prevent fraying, loosening, unraveling, or excessive shifting. (ASTM 4.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE Netplex Structre GUARDRAILS - COMPOSITE STRUCTURE : Bottom of guardrail to be NO more than 28" H on lower edge. (CPSC 5.1.3, ASTM 7.5.5.4, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Guardrails shall completely surround the elevated surfaces except for entrance and exit openings necessary for each event. (ASTM 7.5.5.2, CPSC 5.1.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms elevated more than 30" above protective surfacing must have guardrails. (CPSC 5.1.3, ASTM 7.5.5.1, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE Netplex Structre Top of guardrail to be 38". (CPSC 5.1.3, ASTM 7.5.5.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE BARRIERS - COMPOSITE STRUCTURE : Openings within barriers or between the platform and lower edge of barrier shall be less than 3-1/2". (CPSC 3.3.1, CPSC Table 4, ASTM 7.5.6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Protective barriers shall completely surround the elevated surface except for entrance and exit openings necessary for each event. (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE Netplex Structre There is a 38” high (minimum) protective perimeter barrier on all elevated surfaces 48” above the underlying surface for 5-12 year olds. (ASTM 7.5.6.1, CPSC 5.1.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Top of barrier to be 38”, minimum. (CPSC 5.1.3, ASTM 7.5.6.4, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE SURFACING : Depth of the protective surfacing material correct for the critical height of the equipment. (ASTM F1292, CPSC 2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE Netplex Structre PROTRUSIONS : Test all accessible projections with the three gauges as per ASTM Figures A1.10 through A1.13. (ASTM Figure A1.10, ASTM Figure A1.11, ASTM Figure A1.12, ASTM Figure A1.13, CPSC B.2.1, CPSC B2.2.2, CPSC B.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ROOF HEIGHT : Roofs that are an integral part of a play structure may be any angle, provided that the roof line (lowest edge), excluding support members, is at least 84" above the underlying designated play surface. (ASTM 8.14.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Support members shall be designed to discourage climbing and have no designated play surfaces. (ASTM 8.14.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 PLAY STRUCTURE Netplex Structre SHARP POINTS, CORNERS AND EDGES : A cut-off bolt end projecting beyond the face of the nut shall be free of burrs, sharp points and sharp edges. (ASTM 6.2.4, CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Exposed open ends of all tubing not resting on the ground or otherwise covered should be covered by caps or plugs that cannot be removed without the use of tools. (CPSC 3.4, ASTM 6.2.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No sharp points, corners or edges. (ASTM 6.2, CPSC 3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 96/9/2021 PLAY STRUCTURE Netplex Structre STEPPED PLATFORMS : Distance between stepped platforms for 5-12 yr olds is NO more than 18". (CPSC 5.1.2, ASTM 7.5.7.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE - COMPOSITE STRUCTURE : Equipment is free of corrosion/rust and chipping paint. (CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 106/9/2021 PLAY STRUCTURE Netplex Structre Platforms shall be horizontal within + or - 2 degrees. (ASTM 7.5.1, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms shall not trap water and not accumulate debris. (ASTM 7.5.2, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SUSPENDED HAZARDS : Cables, wires, ropes, or similar flexible components suspended between play units or from the ground to a play unit within 45" of horizontal and is a minimum of 1" at its widest cross section dimension, should not be located in areas of high traffic. (ASTM 6.6, CPSC 3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 116/9/2021 PLAY STRUCTURE Netplex Structre Suspended members should be brightly colored or contrast with surrounding equipment to add o their visibility. (ASTM 6.6.2, CPSC 3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE - COMPOSITE STRUCTURE : Slide use zones shall be a minimum of 6' and equal to the height of the slide up to 8' maximum. (CPSC 5.3.6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There is a minimum use zone of 6’ in all directions for all equipment. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 126/9/2021 PLAY STRUCTURE Netplex Structre Use zones for adjacent pieces of play equipment may overlap if the adjacent designated play stationary surfaces are less than 30” above the protective surfacing (6’ apart). If either adjacent structure exceeds 30”, the minimum distance between the stationary structures should be 9’. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 136/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Double Swoosh Slide CLEARANCE : A clear area, free of equipment, shall surround the slide chute that is 21” wide from the inside edge of slide rail including transition platform, and 60” tall. The clear area shall extend through the slide exit clearance zone. (ASTM 8.5.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE EXIT REGION : Flat sliding surface at the bottom of the slide is a minimum of 11” long at the bottom of the transition point and angle is less than 5º from the horizontal plane. (CPSC 5.3.6.4, ASTM 8.5.5.1, ASTM 8.5.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Double Swoosh Slide For slides greater than 4’ high, the slide exit height is between 7” and 15” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Radius of curvature of the sliding surface in the exit region shall be 30” or greater. (ASTM 8.5.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide exit edges shall be rounded or curved. (ASTM 8.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Slides 4’ high, or less, the slide exit height does not exceed 11” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slides have exit region length of 11” of greater. (CPSC 5.3.6.4, ASTM 8.5.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SLIDE CHUTE : Handrails or other means of hand support shall be provided at the slide chute entrance to channel user from standing to sitting. (CPSC 5.3.6.2, ASTM 8.5.3.1, ASTM 8.5.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Height/length ratio of the sliding surface shall not exceed 0.577 (30º) (height of slide divided by length of slide). (ASTM 8.5.4.1, CPSC 5.3.6.3.4, CPSC Figure 20) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Inside width shall be 16” or greater for 5-12 year olds. (ASTM 8.5.4.3, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum slope, on any part, of the sliding surface is not more than 50º. (ASTM 8.5.4.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Side walls are 4” high on straight slide with open chutes that extends entire length of slide. (ASTM 8.5.4.4, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If the slide is made in several pieces, the sliding surface has no gaps or rough edges at the top of the slide or at section seams which could entangle or trap foreign material. (CPSC 5.3.6.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE TRANSITION PLATFORM : It is recommended that the platform have a minimum length of 14 inches. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No spaces or gaps between the platforms and the start of the slide chute. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide Slide transition platform must be at least as wide as the slide top entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There are sufficient safety barriers at the top of the slide to prevent falls, with hand holds to assist standing to sitting transition and a means to channel the user to the sitting position before slide entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : For slides less than or equal to 6 feet high the use zone in front of the exit should be 6 feet. And for slides greater than 6 feet the use zone in front of the exit should be at least as long as the slide is high up to a maximum of 8 feet. (CPSC 5.3.6.5, ASTM 9.6.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE COMPONENT Double Swoosh Slide The Use Zone extends a minimum of 6’ in all directions from the perimeter of the equipment, including the slide exit if slide is less than or equal to 72” high. (CPSC 5.3.6.5, ASTM 9) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Lolliladder HANDGRIPS : For any flexible elements (chain, cable, ‘S’ hooks, etc.), used to suspend the ring /rung, it shall be no longer than 7”. (ASTM 8.3.5, CPSC 5.3.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE For moveable hanging rings and rungs, the distance between uppermost pivot and bottom of hand-grip shall be no greater than 15”. (ASTM 8.3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Lolliladder STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum center-to-center distance between rungs for overhead equipment is no more than 15” for 5-12 year olds and the openings pass the entrapment test. (CPSC 5.3.2.4, ASTM 8.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum height from center of rung to surfacing is 84” for 5-12 year olds and 54” for wheelchair users. (CPSC 5.3.2.4, ASTM 8.3.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Lolliladder Maximum height of the take-off/landing structure for upper body equipment is less than or equal to 36” for 5-12 year olds. (CPSC 5.3.2.4, ASTM 8.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The horizontal distance from the leading edge of the takeoff or landing structure, or both, out to the first handhold of upper body equipment shall be no greater than 10”. (CPSC 5.3.2.4, ASTM 8.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Lolliladder Where the takeoff or landing point is provided by means of rungs, horizontal distance to the first handhold shall be at least 8”, no greater than 10”. (CPSC 5.3.2.4, ASTM 8.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Loop Ladder ACCESS : Climbers used as access has provided a means of hand support for the use while climbing. (ASTM 7.3.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE For Rung Ladders, flexible components, and arch climbers the stepping surface shall not be above the designated play surface it serves. (ASTM 7.4.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If arch climbers and flexible components are used, they are not the sole means of access to other components of equipment. (CPSC 5.3.2.2, ASTM 7.3.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Loop Ladder HANDGRIPS : Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No bars on the interior of the structure onto which a child may fall from a height of 18” of greater. (CPSC 5.3.2.1.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Loop Ladder Rigid rungs used for hand support during ascent and descent shall be between 0.95” – 1.55” in diameter and shall not twist/rotate on its own axis. (CPSC 5.2.2, ASTM 8.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rope, Chain, or cable with a length of 7.0 inches or less may be attached at one end only. (CPSC 3.5, ASTM 6.6.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Loop Ladder The maximum horizontal opening on access point of deck to be no more than 15” (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : Minimum use zone of 6’ in all directions, unless part of the composite structure. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The use zone of stationary equipment and other equipment may overlap. If the distance of the designated play surfaces are less than 30" it can be a minimum of 72". If the height is greater than 30" than the minimum shall be 108". (CPSC 5.3.2.1.4, ASTM 9.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Netplex Climber FLEXIBLE CLIMBING COMPONENT : Climbing ropes are secure at both ends and not capable of being looped back on itself creating a loop with an inside perimeter greater than 5". (CPSC 3.5, ASTM 6.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Ropes, chains, and cables have not frayed or worn out. (CPSC 4.0) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Netplex Climber HANDGRIPS : Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE BARRIERS : Protective barriers at the top of the platform entrance/exit opening, has a maximum opening of 15”. (CPSC 5.3.2.6, ASTM 8.4.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Netplex Climber STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Mesh structure shall be arranged in a manner so there is no clear opening between flexible members with a vertical dimension greater than 72" and a diameter greater than 20" for climbing nets for 5-12 year olds. (ASTM 8.2.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rope, Chain, or cable with a length of 7.0 inches or less may be attached at one end only. (CPSC 3.5, ASTM 6.6.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Netplex Climber Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible HANDRAIL : Wheelchair accessible ramps less than or equal to 48” above protective surfacing, when designed for 5-12 year olds, shall have two handrails on each side of the ramp that are 26” – 28” high and 12” – 16” high. (ASTM 7.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE BARRIERS : Protective barriers are required on ramp greater than 48” high for 5-12 year olds, and shall have handrails 26” – 28” high on both sides of the ramp. (ASTM 7.5.6.1, ASTM 7.5.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible Wheelchair accessible ramps must have a curb projecting above the ramp a minimum of 2” at both edges when any of the following conditions are present: (1)guardrails or barriers not extending to within 1” of the ramp surface (2)ramps with two rails and no barriers, or (3)ramps where the barrier is beyond the edge of the ramp surface (ASTM 7.5.5.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible Landings with play components shall have a wheelchair parking space, 30” x 48”, which does not reduce the circulation path to less than 36”. (ASTM 7.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Ramps for wheelchair access shall not exceed a horizontal run of 144” (12’). (ASTM 7.2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Ramps shall not trap water and should not encourage accumulation of debris. (ASTM 7.5.2, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible Ramps that are elevated above the protective surfacing and that are accessible to wheelchairs shall provide a clear width of not less than 36”. Clear width may be reduced to 32” for not more than 24” along the path of travel. (ASTM 7.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Ramps, platforms or stationary bridges used for elevated access are exempt from the use zone requirements at the entry area. (ASTM 7.1.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Ramp - Wheelchair Accessible TRANSFER POINTS : Transfer points have wheelchair turning space at base of transfer point; a clear space area of 60” min. T-shaped area in accordance with ASTM Figure A1.47. (ASTM Figure A1.47) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Rollerslide CLEARANCE : A clear area, free of equipment, shall surround the slide chute that is 21” wide from the inside edge of slide rail including transition platform, and 60” tall. The clear area shall extend through the slide exit clearance zone. (ASTM 8.5.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE EXIT REGION : Flat sliding surface at the bottom of the slide is a minimum of 11” long at the bottom of the transition point and angle is less than 5º from the horizontal plane. (CPSC 5.3.6.4, ASTM 8.5.5.1, ASTM 8.5.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Rollerslide For slides greater than 4’ high, the slide exit height is between 7” and 15” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Radius of curvature of the sliding surface in the exit region shall be 30” or greater. (ASTM 8.5.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide exit edges shall be rounded or curved. (ASTM 8.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Rollerslide Slides 4’ high, or less, the slide exit height does not exceed 11” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slides have exit region length of 11” of greater. (CPSC 5.3.6.4, ASTM 8.5.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ROLLER SLIDE : Space between adjacent rollers does not allows a 3/16” rod to enter, either between rollers or adjacent stationary segments. (ASTM 8.9.2.1, CPSC 5.3.6.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Rollerslide There shall be no crush, shear, entrapment, entanglement or catch points between the junctures caused by two of more components. (ASTM 8.9.2, CPSC 5.3.6.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SLIDE CHUTE : Handrails or other means of hand support shall be provided at the slide chute entrance to channel user from standing to sitting. (CPSC 5.3.6.2, ASTM 8.5.3.1, ASTM 8.5.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Height/length ratio of the sliding surface shall not exceed 0.577 (30º) (height of slide divided by length of slide). (ASTM 8.5.4.1, CPSC 5.3.6.3.4, CPSC Figure 20) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Rollerslide Inside width shall be 16” or greater for 5-12 year olds. (ASTM 8.5.4.3, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum slope, on any part, of the sliding surface is not more than 50º. (ASTM 8.5.4.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Side walls are 4” high on straight slide with open chutes that extends entire length of slide. (ASTM 8.5.4.4, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE COMPONENT Rollerslide STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If the slide is made in several pieces, the sliding surface has no gaps or rough edges at the top of the slide or at section seams which could entangle or trap foreign material. (CPSC 5.3.6.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE COMPONENT Rollerslide TRANSITION PLATFORM : It is recommended that the platform have a minimum length of 14 inches. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No spaces or gaps between the platforms and the start of the slide chute. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide transition platform must be at least as wide as the slide top entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE COMPONENT Rollerslide There are sufficient safety barriers at the top of the slide to prevent falls, with hand holds to assist standing to sitting transition and a means to channel the user to the sitting position before slide entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : For slides less than or equal to 6 feet high the use zone in front of the exit should be 6 feet. And for slides greater than 6 feet the use zone in front of the exit should be at least as long as the slide is high up to a maximum of 8 feet. (CPSC 5.3.6.5, ASTM 9.6.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The Use Zone extends a minimum of 6’ in all directions from the perimeter of the equipment, including the slide exit if slide is less than or equal to 72” high. (CPSC 5.3.6.5, ASTM 9) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Sol Spinner CLEARANCE : Rotating equipment shall have a 72" clearance zone free of rigid structural components. Measured from the edge of the rotating component. (ASTM 8.8.1.10) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The clearance between the bottom edge of the equipment and the surfacing should be between 2.38 and 3.5 inches. Or greater than 9.0 Inches (ASTM 8.8.1.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Sol Spinner HANDGRIPS : Hand-grips shall be provided to help children maintain their balance, or the platform where the children sit shall be dish- or tub-like. (ASTM 8.8.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Merry-go-round platforms shall not be provided with an up and down motion. (CPSC 5.3.4, ASTM 8.8.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Sol Spinner Merry-go-rounds shall be constructed to limit their maximum speed to 13 ft/sec. Merry-go-rounds with platform diameters less than 20” is exempt from the speed limitations. (CPSC 5.3.4, ASTM 8.8.6, ASTM 8.8.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No components, including hand-grips, should extend beyond the perimeter of the platform. (CPSC 5.3.4, ASTM 8.8.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rotating platform should be continuous and approximately circular. Difference between minimum and maximum radii of a noncircular platform should not exceed 2”. (CPSC 5.3.4, ASTM 8.8.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Sol Spinner Standing surface shall have a minimum height of 9” and maximum height of 18” above the protective surface when designed for 5-12 year olds. (CPSC 5.3.4, ASTM 8.8.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : Minimum use zone of 6’ in all directions, unless part of the composite structure. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Sol Spinner The use zone extends a minimum of 6’ in all directions from the perimeter of the equipment. (ASTM 9.3.1, CPSC 5.3.4.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The use zone of a spinner with a diameter greater than 20 inches and with a speed limiter is a minimum of 72 inches. It shall not overlap with other use zones. (ASTM 9.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Stepping Pod STEPPING FORMS : Any stepping form greater than 30" tall shall be stationary. (ASTM 8.15.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping form hand supports shall be required at the beginning of pods that are higher than 30" for 5-12 year olds. The hand support height shall be between 22" - 38". (ASTM 8.15.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Stepping Pod Stepping forms shall be no greater than 18" apart when intended for 5 -12 year olds. Dimensions are measured edge to edge between the adjacent stepping surfaces (measurement is horizontal), when forms are at the same height. If stepping forms are at different heights the measurement is at a diagonal. (ASTM 8.15.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms shall be no greater than 30" when used for 5-12, unless hand support is provided. (ASTM 8.15.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms shall contain a minimum designated play surface of 10” in diameter with a slope no greater than 30º from horizontal. (ASTM 8.15.1, ASTM 8.15.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Tree Climber ACCESS : Climbers used as access has provided a means of hand support for the use while climbing. (ASTM 7.3.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE For Rung Ladders, flexible components, and arch climbers the stepping surface shall not be above the designated play surface it serves. (ASTM 7.4.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If arch climbers and flexible components are used, they are not the sole means of access to other components of equipment. (CPSC 5.3.2.2, ASTM 7.3.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Tree Climber HANDGRIPS : Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No bars on the interior of the structure onto which a child may fall from a height of 18” of greater. (CPSC 5.3.2.1.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Tree Climber Rigid rungs used for hand support during ascent and descent shall be between 0.95” – 1.55” in diameter and shall not twist/rotate on its own axis. (CPSC 5.2.2, ASTM 8.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rope, Chain, or cable with a length of 7.0 inches or less may be attached at one end only. (CPSC 3.5, ASTM 6.6.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Tree Climber The maximum horizontal opening on access point of deck to be no more than 15” (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : Minimum use zone of 6’ in all directions, unless part of the composite structure. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The use zone of stationary equipment and other equipment may overlap. If the distance of the designated play surfaces are less than 30" it can be a minimum of 72". If the height is greater than 30" than the minimum shall be 108". (CPSC 5.3.2.1.4, ASTM 9.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE Playshaper Structre CRUSH/SHEAR : There should be no accessible crush or shear points on playground equipment. Such points can be caused by components moving relative to each other or to a fixed component when the equipment moves through its anticipated use cycle. (CPSC 3.1, ASTM 6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTANGLEMENT : Connecting Devices - 'S' hooks and 'C' hooks must be closed as per ASTM Figure A1.19. (ASTM Figure A1.19, CPSC 5.3.8.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE Playshaper Structre Exposed Bolt Ends - two thread rules as per ASTM Figure A1.15(6). (ASTM Figure A1.15(6), CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Projections from a Horizontal Plane - a projection meeting ASTM 6.4.1.1 and projecting upwards from the horizontal is an entanglement hazard, as per ASTM Figures A1.15 through A1.17. (ASTM Figure A1.15, ASTM Figure A1.16, ASTM Figure A1.17, ASTM 6.4.1.1, CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Projections which increase in size - any projection that increases in size or diameter from its initial surface is an entanglement hazard as per ASTM Figure A1.15(7) and A1.16. (ASTM Figure A1.16, ASTM Figure A1.15(7), CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE Playshaper Structre Slides - test as per ASTM Figure A1.14 through A1.17 and A1.23. (ASTM Figure A1.14, ASTM Figure A1.15, ASTM Figure A1.16, ASTM Figure A1.17, ASTM Figure A1.23, CPSC B.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTRAPMENT : COMPLETELY BOUNDED OPENING : Test with head and torso probes as per CPSC Appendix B. (CPSC Appendix B.2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ENTRAPMENT : PARTIALLY BOUNDED OPENING : Test with "fish" probe as per ASTM drawings A1.4 through A1.9. (ASTM Figure A1.4, ASTM Figure A1.5, ASTM Figure A1.6, ASTM Figure A1.7, ASTM Figure A1.8, ASTM Figure A1.9, CPSC b.2.5.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE Playshaper Structre FASTENERS/HARDWARE : All fasteners and hardware are tight, showing no loose play or excessive wear. (CPSC 2.5.2, ASTM 4.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE All fasteners, connecting, and covering devices shall be inherently corrosion-resistant or be provided with a corrosion-resistant coating. (ASTM 4.2.1, CPSC 2.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Steel cable that is permanently affixed to a hanger should be inaccessible or capped to prevent access to frayed wires. Cables & steel cored ropes should be protected to prevent fraying, loosening, unraveling, or excessive shifting. (ASTM 4.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE Playshaper Structre GUARDRAILS - COMPOSITE STRUCTURE : Bottom of guardrail to be NO more than 23" above the platform. (CPSC 5.1.3, ASTM 7.5.5.4, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Guardrails shall completely surround the elevated surfaces except for entrance and exit openings necessary for each event. (ASTM 7.5.5.2, CPSC 5.1.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms elevated more than 20" above protective surfacing must have guardrails. (CPSC 5.1.3, ASTM 7.5.5.1, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE Playshaper Structre Top of guardrail to be 29". (CPSC 5.1.3, ASTM 7.5.5.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE BARRIERS - COMPOSITE STRUCTURE : Openings within barriers or between the platform and lower edge of barrier shall be less than 3-1/2". (CPSC 3.3.1, CPSC Table 4, ASTM 7.5.6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms elevated more than 30" above protective surfacing must have protective barriers. (ASTM 7.5.6.1, CPSC 5.1.3, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE Playshaper Structre Protective barriers shall completely surround the elevated surface except for entrance and exit openings necessary for each event. (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Top of barrier to be 29". (CPSC 5.1.3, ASTM 7.5.6.4, CPSC Table 4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE PROTECTIVE SURFACING : Depth of the protective surfacing material correct for the critical height of the equipment. (ASTM F1292, CPSC 2.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE Playshaper Structre PROTRUSIONS : Test all accessible projections with the three gauges as per ASTM Figures A1.10 through A1.13. (ASTM Figure A1.10, ASTM Figure A1.11, ASTM Figure A1.12, ASTM Figure A1.13, CPSC B.2.1, CPSC B2.2.2, CPSC B.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE ROOF HEIGHT : Roofs that are an integral part of a play structure may be any angle, provided that the roof line (lowest edge), excluding support members, is at least 84" above the underlying designated play surface. (ASTM 8.14.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Support members shall be designed to discourage climbing and have no designated play surfaces. (ASTM 8.14.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 PLAY STRUCTURE Playshaper Structre SHARP POINTS, CORNERS AND EDGES : A cut-off bolt end projecting beyond the face of the nut shall be free of burrs, sharp points and sharp edges. (ASTM 6.2.4, CPSC 3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Exposed open ends of all tubing not resting on the ground or otherwise covered should be covered by caps or plugs that cannot be removed without the use of tools. (CPSC 3.4, ASTM 6.2.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No sharp points, corners or edges. (ASTM 6.2, CPSC 3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 96/9/2021 PLAY STRUCTURE Playshaper Structre STEPPED PLATFORMS : Distance between stepped platforms for 2-5 yr olds is NO more than 12". (CPSC 5.1.2, ASTM 7.5.7.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE - COMPOSITE STRUCTURE : Equipment is free of corrosion/rust and chipping paint. (CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 106/9/2021 PLAY STRUCTURE Playshaper Structre Platforms shall be horizontal within + or - 2 degrees. (ASTM 7.5.1, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Platforms shall not trap water and not accumulate debris. (ASTM 7.5.2, CPSC 5.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SUSPENDED HAZARDS : Cables, wires, ropes, or similar flexible components suspended between play units or from the ground to a play unit within 45" of horizontal and is a minimum of 1" at its widest cross section dimension, should not be located in areas of high traffic. (ASTM 6.6, CPSC 3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 116/9/2021 PLAY STRUCTURE Playshaper Structre Suspended members should be brightly colored or contrast with surrounding equipment to add o their visibility. (ASTM 6.6.2, CPSC 3.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE - COMPOSITE STRUCTURE : Slide use zones shall be a minimum of 6' and equal to the height of the slide up to 8' maximum. (CPSC 5.3.6.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There is a minimum use zone of 6’ in all directions for all equipment. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 126/9/2021 PLAY STRUCTURE Playshaper Structre Use zones for adjacent pieces of play equipment may overlap if the adjacent designated play stationary surfaces are less than 30” above the protective surfacing (6’ apart). If either adjacent structure exceeds 30”, the minimum distance between the stationary structures should be 9’. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 136/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Single Slide CLEARANCE : A clear area, free of equipment, shall surround the slide chute that is 21” wide from the inside edge of slide rail including transition platform, and 60” tall. The clear area shall extend through the slide exit clearance zone. (ASTM 8.5.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE EXIT REGION : Flat sliding surface at the bottom of the slide is a minimum of 11” long at the bottom of the transition point and angle is less than 5º from the horizontal plane. (CPSC 5.3.6.4, ASTM 8.5.5.1, ASTM 8.5.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Single Slide For slides greater than 4’ high, the slide exit height is between 7” and 15” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Radius of curvature of the sliding surface in the exit region shall be 30” or greater. (ASTM 8.5.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide exit edges shall be rounded or curved. (ASTM 8.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Single Slide Slides 4’ high, or less, the slide exit height does not exceed 11” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slides have exit region length of 11” of greater. (CPSC 5.3.6.4, ASTM 8.5.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SLIDE CHUTE : Handrails or other means of hand support shall be provided at the slide chute entrance to channel user from standing to sitting. (CPSC 5.3.6.2, ASTM 8.5.3.1, ASTM 8.5.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Single Slide Height/length ratio of the sliding surface shall not exceed 0.577 (30º) (height of slide divided by length of slide). (ASTM 8.5.4.1, CPSC 5.3.6.3.4, CPSC Figure 20) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Inside width shall be 12” or greater for 2-5 year olds. (ASTM 8.5.4.3, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum slope, on any part, of the sliding surface is not more than 50º. (ASTM 8.5.4.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Single Slide Side walls are 4” high on straight slide with open chutes that extends entire length of slide. (ASTM 8.5.4.4, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If the slide is made in several pieces, the sliding surface has no gaps or rough edges at the top of the slide or at section seams which could entangle or trap foreign material. (CPSC 5.3.6.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE COMPONENT Single Slide Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE TRANSITION PLATFORM : It is recommended that the platform have a minimum length of 14 inches. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No spaces or gaps between the platforms and the start of the slide chute. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE COMPONENT Single Slide Slide transition platform must be at least as wide as the slide top entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There are sufficient safety barriers at the top of the slide to prevent falls, with hand holds to assist standing to sitting transition and a means to channel the user to the sitting position before slide entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : For slides less than or equal to 6 feet high the use zone in front of the exit should be 6 feet. And for slides greater than 6 feet the use zone in front of the exit should be at least as long as the slide is high up to a maximum of 8 feet. (CPSC 5.3.6.5, ASTM 9.6.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE COMPONENT Single Slide The Use Zone extends a minimum of 6’ in all directions from the perimeter of the equipment, including the slide exit if slide is less than or equal to 72” high. (CPSC 5.3.6.5, ASTM 9) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Slidewinder Slide CLEARANCE : A clear area, free of equipment, shall surround the slide chute that is 21” wide from the inside edge of slide rail including transition platform, and 60” tall. The clear area shall extend through the slide exit clearance zone. (ASTM 8.5.6.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE EXIT REGION : Flat sliding surface at the bottom of the slide is a minimum of 11” long at the bottom of the transition point and angle is less than 5º from the horizontal plane. (CPSC 5.3.6.4, ASTM 8.5.5.1, ASTM 8.5.5.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Slidewinder Slide For slides greater than 4’ high, the slide exit height is between 7” and 15” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Radius of curvature of the sliding surface in the exit region shall be 30” or greater. (ASTM 8.5.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slide exit edges shall be rounded or curved. (ASTM 8.5.5.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Slides 4’ high, or less, the slide exit height does not exceed 11” above the protective surfacing. (CPSC 5.3.6.4, ASTM 8.5.5.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Slides have exit region length of 11” of greater. (CPSC 5.3.6.4, ASTM 8.5.5.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE SLIDE CHUTE : Handrails or other means of hand support shall be provided at the slide chute entrance to channel user from standing to sitting. (CPSC 5.3.6.2, ASTM 8.5.3.1, ASTM 8.5.3.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Height/length ratio of the sliding surface shall not exceed 0.577 (30º) (height of slide divided by length of slide). (ASTM 8.5.4.1, CPSC 5.3.6.3.4, CPSC Figure 20) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Inside width shall be 12” or greater for 2-5 year olds. (ASTM 8.5.4.3, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Maximum slope, on any part, of the sliding surface is not more than 50º. (ASTM 8.5.4.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Side walls are 4” high on straight slide with open chutes that extends entire length of slide. (ASTM 8.5.4.4, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If the slide is made in several pieces, the sliding surface has no gaps or rough edges at the top of the slide or at section seams which could entangle or trap foreign material. (CPSC 5.3.6.2, CPSC 5.3.6.3.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 56/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE TRANSITION PLATFORM : It is recommended that the platform have a minimum length of 14 inches. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No spaces or gaps between the platforms and the start of the slide chute. (CPSC 5.3.6.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 66/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide Slide transition platform must be at least as wide as the slide top entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE There are sufficient safety barriers at the top of the slide to prevent falls, with hand holds to assist standing to sitting transition and a means to channel the user to the sitting position before slide entry. (CPSC 5.3.6.2, ASTM 8.5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : For slides less than or equal to 6 feet high the use zone in front of the exit should be 6 feet. And for slides greater than 6 feet the use zone in front of the exit should be at least as long as the slide is high up to a maximum of 8 feet. (CPSC 5.3.6.5, ASTM 9.6.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 76/9/2021 PLAY STRUCTURE COMPONENT Slidewinder Slide The Use Zone extends a minimum of 6’ in all directions from the perimeter of the equipment, including the slide exit if slide is less than or equal to 72” high. (CPSC 5.3.6.5, ASTM 9) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 86/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Stairway HANDRAIL : Continuous handrail from access to platform. (ASTM 7.4.1, CPSC 5.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Handrail is between 0.95” and 1.55” in diameter and does not twist/rotate on their own axis. (CPSC 5.2.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Handrail is between 22” – 26” high for 2-5 year olds. (CPSC 5.2.3.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Stairway SLOPE : Stair slope is less than 50º. (ASTM Table 2, CPSC Table 6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STEPS : Steps do not allow for accumulation of water and/or debris. (ASTM 7.2.2, CPSC 5.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Tread depth, for open or closed risers, is equal to or greater than 7”. (ASTM Table 2, CPSC Table 6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Stairway Tread width is between 12” to 21” for 2-5 single access. Two-abreast ladders are not recommended for 2-5 year olds. (ASTM Table 2, CPSC Table 6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Vertical rise (tread to tread) is equal to or less than 9”. (ASTM Table 2, CPSC Table 6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Stairway Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Stepper Climber ACCESS : Climbers used as access has provided a means of hand support for the use while climbing. (ASTM 7.3.2.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE For Rung Ladders, flexible components, and arch climbers the stepping surface shall not be above the designated play surface it serves. (ASTM 7.4.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE If arch climbers and flexible components are used, they are not the sole means of access to other components of equipment. (CPSC 5.3.2.2, ASTM 7.3.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Stepper Climber HANDGRIPS : Handgrips are between 0.95” and 1.55” in diameter and do not rotate/twist on its own axis. (CPSC 5.2.2, ASTM 7.2.6.4, ASTM 8.3.1.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE STRUCTURE : Footers are stable and buried below ground level and covered by protective surfacing. (CPSC 3.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE No bars on the interior of the structure onto which a child may fall from a height of 18” of greater. (CPSC 5.3.2.1.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021 PLAY STRUCTURE COMPONENT Stepper Climber Rigid rungs used for hand support during ascent and descent shall be between 0.95” – 1.55” in diameter and shall not twist/rotate on its own axis. (CPSC 5.2.2, ASTM 8.2.1) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Rope, Chain, or cable with a length of 7.0 inches or less may be attached at one end only. (CPSC 3.5, ASTM 6.6.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Structure shows no corrosion/rust, chipping paint, visible rotting, or broken equipment. (CPSC 4.0, CPSC 2.5.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 36/9/2021 PLAY STRUCTURE COMPONENT Stepper Climber The maximum horizontal opening on access point of deck to be no more than 15” (CPSC 5.1.3, ASTM 7.5.6.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE USE ZONE : Minimum use zone of 6’ in all directions, unless part of the composite structure. (CPSC 5.3.2.1.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE The use zone of stationary equipment and other equipment may overlap. If the distance of the designated play surfaces are less than 30" it can be a minimum of 72". If the height is greater than 30" than the minimum shall be 108". (CPSC 5.3.2.1.4, ASTM 9.2.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 46/9/2021 Main Office: 138 Ludlowville Rd. Lansing, NY 14882 1.800.726.4833 fax: 607.533.4108 PLAY STRUCTURE COMPONENT Stepping Pod STEPPING FORMS : Any stepping form greater than 30" tall shall be stationary. (ASTM 8.15.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping form hand supports shall be required at the beginning of pods that are higher than 20” for 2-5 year olds. The hand support height shall be between 22” – 38”. (ASTM 8.15.4) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms intended for 2-5 shall be stationary. (ASTM 8.15.5) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE 6/9/2021 Page 1 PLAY STRUCTURE COMPONENT Stepping Pod Stepping forms shall be no greater than 12” apart when intended for 2 -5 year olds. Dimensions are measured edge to edge between the adjacent stepping surfaces (measurement is horizontal), when forms are at the same height. If stepping forms are at different heights the measurement is at a diagonal. (ASTM 8.15.6) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms shall be no greater than 20” above the protective surfacing when used for 2-5 year olds, unless hand support is provided. (ASTM 8.15.3) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Stepping forms shall contain a minimum designated play surface of 10” in diameter with a slope no greater than 30º from horizontal. (ASTM 8.15.1, ASTM 8.15.2) INSPECTORS' FINDING DESIGNATION Compliant INSPECTION ITEM HAZARD PRIORITY RATING REPAIR NOTE Parkitects, Inc. 138 Ludlowville Road, Lansing, NY 14882 1.800.726.4833 / fax: 607.533.4108 Page 26/9/2021