Loading...
HomeMy WebLinkAboutZoning Analysis - Breeze Preliminary Analysis - 4-8-2022 TO: Lisa Nicholas, Acting Director of Planning & Development Nikki Cerra, Environmental & Landscape Planner FROM: Megan Wilson, Zoning Administrator DATE: April 8, 2022 RE: Preliminary Zoning Analysis – The Breeze, 121-125 Lake Street I have reviewed the site plan review application for The Breeze, 121-125 Lake Street, dated February 15, 2022, and have determined that the project does not meet the requirements for the R-3a zone. The project will require several area variances in order to be constructed as currently proposed. Please note that the provided site plan review application is missing some information required for a complete zoning analysis. I will update this zoning analysis upon receipt of additional information. 1. Off-Street Loading: The R-3a district requires one off-street loading space for the first 10,000 SF of floor area and an additional off-street loading space for each 15,000 SF of building floor area, with a maximum of 4 off-street loading spaces. This project will require the maximum 4 off-street loading spaces. No off-street loading is proposed. 2. Maximum Building Height in Feet: The R-3a district allows buildings up to 40’ in height. The applicant states that an area variance from maximum building height is required; however, there is insufficient information to determine whether a variance is required and, if so, what the extent of the variance will be. The applicants must provide information on their calculation of average grade plane. 3. Maximum Lot Coverage by Buildings: There is insufficient information to determine whether the proposal meets the requirement. The R-3a district allows a maximum 35% lot coverage by buildings. The applicants must provide more detailed information on building footprint square footage and which building components were included in their calculation. 4. Rear Yard: The minimum rear yard requirement for the R-3a district is either 50’ or 25% of the lot depth (but not less than 20’). Based on the depth of this lot, the property is subject to a 50’ minimum rear yard. The proposed building is located within the required rear yard. The minimum rear yard provided is 41.25’, resulting in a deficiency of 8.75’ or 17.5% of the required yard. Please feel free to contact me with any questions or if you need any additional information. CITY OF ITHACA 108 E. Green St. — Third Floor Ithaca, NY 14850-5690 DEPARTMENT OF PLANNING, BUILDING, ZONING, & ECONOMIC DEVELOPMENT Division of Planning & Economic Development Telephone: Planning & Development – 607-274-6550 Community Development/IURA – 607-274-6559 E-Mail: dgrunder@cityofithaca.org City of Ithaca Board of Zoning Appeals Worksheet Appeal Number -Address 121-125 Lake Street Use District R-3a Date 4/7/2022 Applicant SWBR Owner Visum Application Type:Zoning Analysis for SPR Column Number 2 3 4 5 6 7 8 9 10 11 12 13 14/15 16 Column Title Use Accessory Use Off-Street Parking Off-Street Loading Lot Area (Sq. Feet) Lot Width (Feet) Number of Stories Height in Feet % of Lot Coverage Front Yard Side Yard Other Side Yard Rear yard: % of depth or number of feet, whichever is less Minimum Building Height Existing Condition and Use District Regulations for Existing Multiple Dwellings 4 40 35%10 10 5 25% or 50' but not less than 20'None Note Non- Conforming Conditions Proposed Condition and/or Use Multiple Dwellings 77 0 61,730 156.76'4 ?33.7%10 77 5 41.25' District Regulation for Proposed Multiple Dwellings 77 4 61,500 50'4 40 35%10 10 5 50'None Note Non- Conforming Conditions for Proposal OK OK Def.OK OK OK Def.*OK**OK OK OK Def. Notes: ** Based on estimatel need confirmation of building footprint. * Based on applicants' statement; Need information on average grade plane calculation.