Loading...
HomeMy WebLinkAboutPB Packet 2024-05-21 TOWN OF ITHACA PLANNING BOARD Shirley A. Raffensperger Board Room, Town Hall 215 North Tioga Street Ithaca, New York 14850 Tuesday, May 21, 2024 6:30 P.M. Members of the public are welcome to attend in-person at Town Hall or virtually via Zoom. The public will have an opportunity to see and hear the meeting live and provide comments in-person or through Zoom at https://us06web.zoom.us/j/83643764382. If the public would like to attend the meeting for viewing purposes only, it is recommended to watch the livestream video on YouTube (https://www.youtube.com/channel/UCC9vycXkJ6klVIibjhCy7NQ/live). AGENDA 1. State Environmental Quality Review (SEQR) discussion for the proposed Cornell University Meinig Fieldhouse Indoor Sports and Recreational Facility located at Robison Alumni Fields on Tower Road on the Cornell University campus. The project involves replacing the Robison Alumni Fields with a 90,000+/- square foot, 56-foot-tall indoor fieldhouse building and a new synthetic outdoor multipurpose field along with new sidewalks and pedestrian connections, stormwater facilities, landscaping, lighting, and other site elements. The project will be largely located within the City of Ithaca with a portion in the Town of Ithaca. This is a Type I Action under the State Environmental Quality Review Act and is subject to environmental review. The City of Ithaca Planning and Development Board declared their intent to be the Lead Agency to coordinate the environmental review. The Town of Ithaca Planning Board concurred with the Lead Agency declaration on January 16, 2024. Cornell University, Owner; Kimberly Michaels, TWM, a Fisher Associates Landscape Architecture Studio, Applicant/Agent. 2. PUBLIC HEARING: Consideration of a recommendation to the Town of Ithaca Town Board regarding proposed changes to the Official Map of the Town of Ithaca. 3. Persons to be heard. 4. Approval of Minutes. 5. Other Business. 6. Adjournment. C.J. Randall Director of Planning 607-273-1747 NOTE: IF ANY MEMBER OF THE PLANNING BOARD IS UNABLE TO ATTEND, PLEASE NOTIFY CHRIS BALESTRA AT 607-273-1747 or CBALESTRA@TOWNITHACANY.GOV. (A quorum of four (4) members is necessary to conduct Planning Board business.) Accessing Meeting Materials Online Site Plan and Subdivision applications and associated project materials are accessible electronically on the Town’s website at https://townithacany.gov/meeting-calendar-agendas/ under the calendar meeting date. TOWN OF ITHACA PLANNING BOARD PUBLIC HEARING NOTICE The Planning Board will hold a public hearing on Tuesday, May 21, 2024, starting at 6:30 P.M. on the following matter: Consideration of a recommendation to the Town of Ithaca Town Board regarding proposed changes to the Official Map of the Town of Ithaca. Members of the public are welcome to attend in-person at Town Hall (215 North Tioga Street, Ithaca, NY) or virtually via Zoom. The public will have an opportunity to see and hear the meeting live and provide comments in-person or through Zoom at https://us06web.zoom.us/j/83643764382. If the public would like to attend the meeting for viewing purposes only, it is recommended to watch the livestream video on YouTube (https://www.youtube.com/channel/UCC9vycXkJ6klVIibjhCy7NQ/live). Any person wishing to address the board will be heard. In addition, comments can be sent via email to townclerk@townithacany.gov up to the end of business the day of the meeting and all comments will be forwarded to the board. Additional information is available at https://townithacany.gov/. C.J. Randall, Director of Planning DEPARTMENT OF PLANNING 215 N. Tioga St 14850 607.273.1747 www.town.ithaca.ny.us TO: Planning Board Members FROM: Christine Balestra, Senior Planner DATE: May 14, 2024 RE: Cornell University Meinig Fieldhouse Indoor Sports and Recreation Center Project – Discussion of Additional Materials, SEQR Segmentation Enclosed please find additional materials related to the Cornell Meinig Fieldhouse project, dated April 19, 2024. The Planning Board received a complete packet of materials for the Meinig Fieldhouse project, including a Full EAF Part 1, at the sketch plan review meeting on January 16, 2024. The Board issued concurrence with the City of Ithaca Planning & Development Board (PDB) to act as the Lead Agency in the environmental review of the project at that meeting. The City PDB formally declared themselves the Lead Agency in the New York State Environmental Quality Review (SEQR) process on January 23, 2024. Board members may recall that the Meinig Fieldhouse project was on the February 20, 2024, Planning Board meeting agenda for SEQR discussion but was pulled from the agenda at the request of the applicant. The applicant has since revised the project scope to include a larger, multipurpose outdoor synthetic playing field located adjacent to the proposed Meinig Fieldhouse and has proposed relocating the field hockey field to the Ellis Hollow/Game Farm Road area in the Town of Ithaca. The applicant is requesting “permissible segmentation” of the environmental review process, to allow the new field hockey field project in the Town of Ithaca to undergo a separate environmental and approval review process than the Meinig Fieldhouse project. The purpose of the May 21, 2024, meeting is for the Town Planning Board to discuss the revised project materials, and to consider comments to make to the City PDB about whether SEQR segmentation might occur and if so, whether segmentation is appropriate for this project. The City of Ithaca PDB, as the Lead Agency, will review the same set of revised application materials at their meeting on May 28, 2024. However, the City PDB is not expected to make a decision on SEQR segmentation or an environmental determination until June or July. The Town Planning Board will review a revised Full EAF Part 3, provided by the City after May 28th, and will provide feedback, comments, and corrections on the FEAF at a future meeting (possibly one of the June meetings). SEQR segmentation The additional application materials provided by the applicant, dated April 19, 2024, anticipate future development of the field hockey field as an additional field at the existing Ellis Hollow Athletics Complex on Ellis Hollow/Game Farm Roads in the Town of Ithaca, and not located adjacent to the proposed Meinig fieldhouse (as stated in the December 15, 2023, materials). A SEQR review of the field hockey field that is separate from the SEQR review for the Meinig fieldhouse and the adjacent multipurpose field might be considered a “segmentation” of the environmental review process. 2 According to SEQR regulations, segmentation means “the division of the environmental review of an action, such that the various activities or stages are addressed as though they were independent, unrelated activities, needing individual determinations of significance.” While normally prohibited, segmentation is permitted by the provisions of 6 NYCRR Part §617.3(g) in certain circumstances. The SEQR Handbook gives examples of three circumstances, when considered together, that may warrant segmentation when a project has several phases: • Information on future project phase(s) is speculative, • Future phase(s) may not occur, or • Future phase(s) are functionally independent of current phase(s). §6 NYCRR Part 617.3 (g) (1) of the SEQR regulations states that “If a lead agency believes that circumstances warrant a segmented review, it must clearly state in its determination of significance, and any subsequent EIS, the supporting reasons, and must demonstrate that such review is clearly no less protective of the environment.” As the Lead Agency in the environmental review of the Meinig Fieldhouse project, the City of Ithaca PDB will determine if segmentation would occur if a SEQR review of the proposed Ellis Hollow/Game Farm Road field hockey field occurs separately from the SEQR review for the Meinig fieldhouse and multipurpose field. If the City PDB determines there is segmentation, it would then determine whether circumstances warrant a segmented review. The Town of Ithaca Planning Board, as an Involved Agency in the environmental review process, can comment on these SEQR segmentation issues and can suggest language for the city to consider in its resolution. The Planning Board should discuss this at the meeting on May 21st. Please feel free to contact me by phone at (607) 273-1721, extension 121 or by email at cbalestra@town.ithaca.ny.us if you have questions before the meeting. Att. Cc: Elisabete Godden, Project Manager, Cornell University Facilities and Campus Services Kimberly Michaels, Director of Landscape Architects, TWM, a Fisher Associates Landscape Architecture Studio Lisa Nicholas, Director of Planning and Economic Development, City of Ithaca Leslie Schill, Director of Campus Planning, Cornell University, Office of the University Architect 1 New Baseball Field at Game Farm Road Preliminary Site Plan, SEQR & Special Permit Review Town of Ithaca October 19, 2021 5-21-2024: Excerpt from 2021 Cornell Hoy/Booth Baseball Field application - presentation contains Master Plan for future athletic field development on Ellis Hollow and Game Farm Roads (including future field hockey field) •Baseball is a NCAA Division I varsity sport with a long history at Cornell University and recently celebrated its 150th year in the Athletics department •Hoy Baseball Field on Cornell’s Central Campus will be the site for a new academic building •The Game Farm Road site is proposed for baseball development. This location is envisioned to grow slowly, over time to accommodate other athletic fields. Purpose and Need Project Location Cascadilla CreekHoy Baseball Field Project Location March 10, 2016 Existing Site Conditions Long Range Vision Long Range Vision Long Range Vision 18 Archaeology Phase 1a Study Area 19 Archaeology Phase 1b Study Area Meinig Fieldhouse Indoor Sports and Recreation Facility Additional Materials Cornell University Ithaca, NY April 19, 2024 TWM - A Fisher Associates Landscape Architecture Studio Fisher Associates, P.E., L.S., L.A., D.P.C. April 19, 2024 C.J. Randall, Director of Planning Department of Planning, Town of Ithaca 215 North Tioga Street Ithaca, NY 14850 Dear Director Randall, Attached please find additional site plan review materials regarding the Meinig Fieldhouse / Alumni Fields project for Cornell University. Thank you for all of your time, attention, and dedication to date. As a result of changes to the project scope, including the reconfiguration of the outdoor field from a field hockey field to a multi-purpose field (“Alumni Fields”) and relocation of the field hockey field to a new site on Game Farm Road (solely in the Town of Ithaca), Cornell University respectfully requests permissible segmentation to allow SEQR review to occur separately for each project. A letter formally requesting that the City Planning Board make a finding of permissible segmentation of environmental review is enclosed within this package. We intend to pursue SEQR review and site plan review for the field hockey field on Game Farm Road separately, with the Town of Ithaca Planning Board acting as lead agency. As we work through SEQR coordinated review, including the requested permissible segmentation, and site plan review for Meinig Fieldhouse / Alumni Fields, submitted materials will be organized based on outstanding items for review. In the following package you will find responses to questions from the planning board and additional information pursuant to SEQR, permissible segmentation, and site plan review, including additional reports, drawings, and specifications. Included with this letter is the following: 1. Updated narrative explaining project changes 2. Written request for permissible segmentation 3. Responses to SEQR-related City of Ithaca and Town of Ithaca Planning Board Questions 4. Updated Civil Plan Set 5. Updated Landscape Plan Set 6. Updated Site Lighting/Photometrics Plans 7. Cornell University Energy Strategy Letter 8. Synthetic Turf Specifications and Additional Information Letter, Haley & Aldrich 9. Updated Geotechnical Report We are targeting the following schedule moving forward for the Meinig Fieldhouse / Alumni Fields project: May – City Planning Board makes a finding of permissible segmentation June – SEQR Review July – SEQR Determination TWM - A Fisher Associates Landscape Architecture Studio Fisher Associates, P.E., L.S., L.A., D.P.C. August – consideration of Preliminary Site Plan Approval September – zoning variance review, Town of Ithaca Zoning Board of Appeals October – consideration of Final Site Plan Approval If you have any questions or require further information, please do not hesitate to call. We are hoping to discuss permissible segmentation at the next Town of Ithaca Planning Board Meeting on May 21st. A copy of this letter and all materials will also be sent to the City of Ithaca. Sincerely, Kimberly Michaels Director of Landscape Architecture TABLE OF CONTENTS Description of Project Changes & Responses to Planning Board Questions ................................................... 01 Revised Site Plan ....................................................................................... 01 Revised Site Access and Circulation .......................................................... 02 Revised Operations and Maintenance Strategy ....................................... 03 Landscaping and Planting Plan ................................................................. 03 Stormwater Updates and Additional Information .................................... 04 Revised SEQR Calculations, Site Work Details .......................................... 05 Zoning Variances ....................................................................................... 05 Renewable Energy / “Solar Ready” Design ............................................... 05 Ithaca Energy Code Supplement ............................................................... 06 Red-Tailed Hawks Nest ............................................................................. 07 Artificial Turf ............................................................................................. 07 Construction Staging Information ............................................................. 09 Appendices ............................................................................. 13 Appendix A: Permissible Segmentation Request Appendix B: Cornell University Energy Strategy Letter Appendix C: Synthetic Turf Information Letter, Haley and Aldrich Appendix D: Synthetic Turf Public Comment Response Letter Appendix E: Vehicle Tracking Study Geotechnical Report ................................ Under separate cover Technical Drawing Set .............................. Under separate cover Description of Project Changes & Responses to Planning Board Questions Revised Site Plan As previously noted in the December 2023, Site Plan Review Application, Cornell University is proposing to construct the Meinig Fieldhouse, an indoor sports and recreation center, on Cornell’s Central Campus in the area currently occupied by Robison Alumni Fields. Since the original submission, the project scope has been revised to show a new multi-purpose athletic field in the location of the previously proposed field hockey outdoor turf field to the west of the proposed Meinig Fieldhouse building. The previous submission included a proposed 77,354 SF field hockey field with amenities. The revised project scope includes a proposed 92,098 SF (93,098 SF with perimeter curb) multi-purpose synthetic turf athletic field that will support a variety of sports activities for much of the year. The updated site plan removes several elements that were previously proposed for the field hockey field, including the removal of the flagpole, team storage area, team shelters, press box, and spectator seating. The proposed scoreboard has been relocated to the southern portion of the field. Due to the field size expansion, the sports lighting poles have shifted slightly further apart. The sports lights to the west (F3-F4) of the multi-purpose field have been shifted towards the field corners to avoid existing underground utilities and surface features remaining on site. Due to this shift, these two poles now have a mounting height of 80 feet, while F1-F2 remain at a mounting height of 70 feet. The scope of the Meinig Fieldhouse portion of the project has not changed. The Meinig Fieldhouse is a 90,000SF building at 56 feet tall which will enable year-round practice and play space for athletes as well as limited competition venue for NCAA Lacrosse Players. Revised Site Access and Circulation A revised Site Access and Circulation diagram is provided below. As noted in the original Site Plan Review Application dated December 2023, very little parking is expected to be needed daily as the facility is primarily expected to be used for students for practice, recreation, and club play. Bicycle parking on the site has been reconfigured and includes a total of 21 bicycle parking spaces separated into three bicycle parking facilities. As noted in the December 2023 submission, bicycle parking facilities will be easily accessible from pedestrian or fire access pathways and will not intrude into these walkways. Due to changes to the site layout, only one (1) non-ADA parking space will be removed from the Bartels Lot to the south because of the proposed project. Three (3) ADA accessible parking spaces will remain in the Alumni Lot to the north, and 8 ADA accessible parking spaces in the Bartels Lot to the south. Revised Operations and Maintenance Strategy The revised Operations and Maintenance strategy includes minor modifications to the areas in the site identified for piling snow, including removal of a snow piling area on the northeastern portion of the field, and relocation of one of the southern snow piling areas. The location of the concrete dumps ters on heavy-duty concrete pads, accessible via flush curb from the parking area adjacent to the Friedman Wrestling Center, remains unchanged from the December 2023 submission. Service access to the Meinig Fieldhouse via 10-feet wide roll-up door, as well as proposed service access drives and delivery routes, remain unchanged from the December 2023 submission. Landscaping and Planting Plan As noted in the December 2023 submission, natural landscaping around the building will include a variety of species with a strong emphasis on using native, non-invasive plant materials. The City of Ithaca Planning Board requested additional information regarding tree clearing and protection and tree planting, as well as an updated planting plan. During construction, a total of 18 Quercus rubra will be removed, and 60 trees will be planted on site, resulting in a net addition of 42 trees on the site. As noted in the Planting Plan under separate cover, the trees to be planted include: 1. (11) 2.5” caliper Acer rubrum ‘Redpointe’ 2. (14) 8-10’ height Amelanchier x grandiflora ‘Autumn Brilliance’ 3. (18) 8-10’ height Betula papyrifera ‘Oenci’ 4. (10) 8-10’ height Cercis canadensis ‘Northern Strain’ 5. (7) 2.5” caliper Ulmus americana ‘Princeton’ A variety of shrubs, perennials, ground covers, and a native planting mix are also proposed to be planted on the site. Reference L5-01 and L5-02 in the revised technical drawing set under separate cover for additional information. Stormwater Updates and Additional Information All of the proposed stormwater management practices will be located within the City of Ithaca. Runoff from the artificial turf field and a majority of the proposed fieldhouse will be conveyed to a single below grade detention system with the required volume to detain the 1% chance storm event. This system will use manufactured chamber units encased in an envelope of stone and be located underneath the turf field. Diversion structures will be placed upstream of the detention system to direct runoff from low flow events to the system’s pretreatment “isolator rows”. Higher flow events will bypass the isolator rows and enter the system directly. An outlet control structure will be installed downstream of the system to ensure discharge rates do not exceed the existing conditions. Sand filter units, located underneath the below grade detention system, will provide water quality treatment for the required water quality volume (WQv). A bioretention filter located in the open space north of the fieldhouse will provide additional WQv treatment and satisfy the project runoff reduction volume (RRv) requirement. Additional WQv will be provided by a hydrodynamic separator located in the landscaped area south of the proposed fieldhouse. Revised SEQR Calculations, Site Work Details Due to changes to the project scope, including the expansion of the outdoor turf field to a +/- 92,000SF field (see “Revised Site Plan” above), impervious surface on the site will increase from 4.07 acres – including the existing natural grass turf on the site, which is considered an impervious surface due to the underdrain systems underneath the field – to 5.79 acres, or a net increase of 1.72 acres of impervious surface. Construction will require 3,600 CY of cut and fill for building foundations which will remain on site. No soil materials will be leaving the site. As a result of the change in the scope of the Alumni Field work, an additional 3,500 CY of imported aggregate will be required. The maximum depth of excavation will be eight (8) feet. An updated geotechnical report is included as an appendix with additional information relevant to excavation and site preparation. The anticipated water usage on the site is not anticipated to change as a result of the changes to the project scope. Zoning Variances Unchanged from the original December 2023 submission, two zoning variances from the Town of Ithaca Zoning Board of Appeals are required for the proposed project because Cornell’s campus is zoned Low Density Residential in the Town of Ithaca. The project will require an area variance due to the height of the Meinig Fieldhouse. The peak of the sports complex roof is approximately 56 feet from average grade. The Town of Ithaca’s Zoning Code §270-59 generally limits building height to 38 feet below interior grade or 36 feet below exterior grade (whichever is lower). The proposed project will require a second variance from the Town of Ithaca Zoning Board of Appeals due to an exceedance of allowable lot coverage as specified in the Town of Ithaca’s Zoning Code §270-61, which permits a maximum lot coverage of 10%. The proposed project will be constructed on Town of Ithaca tax parcel 67.-1-12.3, which is 31 acres in total size and includes approximately eight (8) buildings. Existing structures on the parcel exceed the maximum 10% (3.1 acre) lot coverage allowance at 3.12 acres; therefore, an area variance is required. Renewable Energy / “Solar Ready” Design Renewable energy production (REP) required to satisfy portions of the IECS renewable energy credits for the Meinig Fieldhouse will be allocated from the University’s existing renewable energy portfolio. At this time, the university receives qualifying REP from the following assets where the University has worked with development partners to create new renewable energy assets: 2.8MWdc Cornell University Ruminant Center Solar Farm – Harford, NY 5.7MWdc Cornell University Agricultural Experiment Station Solar Farm – Ledyard, NY 2.8MWdc Cornell University NYS Agricultural Experiment Station Solar Farm – Geneva, NY 26.5MWdc Cascadilla Community Solar Farm at Cornell – Ithaca, NY Cornell University manages all utilities, including renewable energy utilities, as an interconnect ed campus district. When considered in a campus context, the capacity for installation of solar equipment on individual building rooftops for specific projects is often mismatched with the IECS REP requirement, and must be supplemented. The University continues to invest in larger-scale renewable energy projects to increase the institution’s renewable energy portfolio at a district scale. Ground-mount solar energy systems presently yield more electrical generation per dollar spent than rooftop solar. They also offer more robust opportunities to use the Ithaca campus as a living laboratory to develop and demonstrate co-benefits of renewable energy development to help address the challenges facing deployment of renewables at scale, state-wide. For these reasons, the University is currently focusing investment on these types of projects. The Meinig Fieldhouse will be constructed as a solar-ready facility to be prepared for the time the campus district utility system requires this implementation to support broad campus energy and sustainability goals. This pre-positions the facility for the possible addition of solar renewable energy systems by providing interior electrical pathways, structural design capacity within the building framing to support roof loads associated with solar panel equipment, and space within electrical rooms for future equipment installation. This allows for the Fieldhouse to be aggregated into a larger pool of available project-ready sites in the future. Ithaca Energy Code Supplement As noted in the Design Development Phase Energy Analysis (see attached), the project will pursue compliance with the Ithaca Energy Code Supplement via the LEED-based compliance pathway and the IECS Section C402 Prescription Compliance Path/Easy Path. Reference “Renewable Energy/Solar Ready Design” above for additional information regarding the approach to the IECS renewable energy credits for the project. In addition to the renewable energy credits, the project must earn at least seven (7) additional points to achieve code compliance. The project has the option to pursue points from the following improvement categories: • AI5 – Modest window-to-wall ratio (1 point) • RE1 – Renewable energy systems (3 points) • OP2 – Walkability (1 point) • OP1 – Development Density (1 point) • OP6 (Custom energy improvement (1 point) An IECS Compliance Checklist is provided on the following page. IECS Prescriptive Points LTHW - LEED Heat Pumps for Space Heating EE1 Heat Pumps for Domestic Water Heating EE2 Commercial Cooking Electrification EE3 Smaller Building/Room Size AI1 Heating Systems in Heated Space AI2 Efficient Building Shape AI3 Right-Lighting AI4 Modest Window-to-wall ratio AI5 1 Renewable Energy Systems RE1 3 Biomass Space Heating RE2 Development Density OP1 1 Walkability OP2 1 Electric Vehicle Parking Spaces OP3 Adaptive Reuse OP4 Meet NY Stretch Code OP5 Custom Energy Improvement OP6 1 Total IECS Points 7 Please note that this list is tentative, and the project may ultimately seek a different combination of IECS points when submitting a final design to the City of Ithaca Building Division for IECS compliance review. Red-Tailed Hawk Nest As noted in the SPR Application package submitted in December 2023, two existing sports lighting poles currently serve as the preferred nesting location for a pair of beloved Cornell red -tailed hawks. Though the poles will no longer serve athletics lighting needs, both existing sports lighting poles will be retained for hawk nesting, as part of the proposed site plan; disturbance to the hawks is not anticipated. The nesting season for red-tailed hawks typically runs from March to June, which is being taken under consideration for the construction of the fieldhouse and outdoor field. The hawks seem especially resilient, since numerous construction projects have occurred during their occupation in this area of campus, and they continue to make th is location their home. Artificial Turf The synthetic turf system at the Meinig Fieldhouse and Alumni Field locations are composed of a dual long-fiber system, with both slit film and monofilament polyethylene fibers, sand and rubber infill, and a performance shock pad. The synthetic turf system is chosen based on the One Turf Concept that considers individual components, longevity, and overall performance requirements including player safety. The One Turf Concept was created by International Federation of Association Football (FIFA), World Rugby, and International Hockey Federation (FIH). Performance requirement parameters, as shown in the chart below, include shock absorption, vertical deformation, rotational resistance, impact attenuation (HIC), ball roll (large ball), and vertical ball rebound. Synthetic turf fields are replaced every 8-12 years depending on performance and wear. During the field replacement process, the existing turf will be recycled. Cornell University is advancing the use of synthetic turf to provide a surface that can be used for athletic, recreation and wellness activities even when the weather is not favorable. Due to rain and/or snow, synthetic turf allows for heavy use by all university programs throughout the entire year. The current grass fields are not usable November – April and during periods of prolonged inclement weather. Additionally, synthetic turf significantly reduces the need for high levels of maintenance: mowing, fertilizing, painting lines, and repairing any damage done to the grass. Growth potential is a concept used to describe the ability of grass to grow at a certain temperature and is useful for estimating how the grass may grow. On natural grass sports fields, growth is required for surfaces to recover from use. Therefore, we can consider the growth potential curve (included below) like the field’s utilization capacity based on its ability to recover (100% is maximum potential growth). In a perfect scenario, all field utilization would occur between May and October when the grass has the capacity to grow and recover. Field use must be adapted appropriately to preserve field quality, safety and encourage adequate recovery during periods of low growth. However, that is not realistic for spring and fall athletics that occur outside this window (or simply when students are on campus). Fields are in consistent use from January through November. Construction Staging Information Construction staging and laydown will be located north of the proposed building and west of the existing Robison Alumni Field Hockey Field. Palm Road lot will be used as overflow contractor parking and staging as needed. Construction vehicles will be directed to access the site via a prescribed route from Tower Road for new field work and from Campus Road for the building work. The project will generate approximately 1,200 truck roundtrips over a three- month period. The largest volumes of truck activity would be associated with importing general fill used for rough grading the site and bringing the new building up to finished floor elevation, when a maximum of 30 trucks could be expected to arrive on site in a single day. Most long-distance delivery routes to/from Cornell’s campus utilize route 81 north or south. Traffic leaving the site and heading north would exit campus on Tower Road, utilize route 366 to route 13 to 81 north. Traffic leaving the site and heading south would exit campus on Hoy Road, use Pine Tree Road to route 79 to 81 south. Route diagrams are included below. Traffic leaving the site and heading north would use route 366 to route 13 to 81 north. Traffic leaving the site and heading north would use route 366 to route 13 to 81 north, zoomed in. Traffic leaving the site and heading south would use Pine Tree Road to route 79 to 81 south. Traffic leaving the site and heading south would use Pine Tree Road to Route 79 to 81 south, zoomed in. Site Construction logistics, approximately November 2024 – March 2026 Appendix A: Permissible Segmentation Request April 19, 2024 Lisa Nicholas, Director of Planning & Development, City of Ithaca Department of Planning, Building, Zoning & Economic Development 108 East Green Street, Ithaca, NY, 14850-5690 C.J. Randall, Director of Planning Department of Planning, Town of Ithaca 215 North Tioga Street Ithaca, NY 14850 To City & Town Planning Boards and Staff, Project Updates The City has been established as the lead agency for purposes of environmental review of Cornell’s proposed Meinig Fieldhouse project, located on the university’s central campus, that crosses the City- Town municipal boundary. The City and Town Planning Boards are engaged in a coordinated environmental review of that project, which will be built in part on the location of the existing field used by the women’s field hockey team. Cornell had initially proposed to build a new field hockey field on the western end of the Fieldhouse project site. Cornell has now determined it is in the best interests of the university to instead build the new field hockey field at Game Farm Road in the Town of Ithaca, approximately 1.5 miles from the Fieldhouse site. The portion of the Fieldhouse project site that would have been a field hockey facility is now proposed to be a multi-purpose field that will support use by a greater variety of athletic teams and student groups than a dedicated field hockey facility. Updated application materials regarding this project change have been provided to the City and Town. Cornell submits this letter in support of its request that, to the extent the City Planning Board deems it legally necessary, it segment the environmental review of the Meinig Fieldhouse project from the environmental review of the Game Farm Road field hockey project. Segmentation Even assuming that these two projects initially meet the requirements to be considered the “whole action” proposed by Cornell, segmentation of environmental review for the new field hockey field from the review of the Meinig Fieldhouse project on Cornell’s central campus will not be less protective of the environment, and is permissible and appropriate under state law and regulations (6 NYCRR 617.3(g)(1)). Segmentation is “the division of the environmental review of an action such that various activities or stages are addressed … as though they were independent, unrelated activities, needing individual determinations of significance” (6 NYCRR 617.2(ah); City of Ithaca Municipal Code §176-2). In determining whether segmentation is appropriate in a given case, the lead agency is directed to consider factors such as: i) the purpose, goal, and timing of each segment; ii) the geographic locations involved; iii) whether the segments share a common impact or owner; iv) the segments’ functional dependence on one another; v) whether approving one segment commits the agency to approve other segments; and vi) the definitiveness of information about future segments (SEQR Handbook, pages 53- 54). First, the projects are functionally independent and will not have related or compounded construction or operational environmental impacts that cannot be appropriately assessed in a segmented review. These are not two phases of the same project, but rather two independent projects connected only by the location of the existing field hockey field that is being replaced. The proposed Fieldhouse and multi- purpose athletic field on central campus can proceed and be fully functional regardless of the outcome of the proposed field hockey development. See Concerned Citizens for the Environment v. Zagata, 243 A.D.2d 20, 22 (3d Dep’t 1998) (upholding permissible segmented review of waste transfer station and incinerator located at the same location because the facilities were functionally independent). The projects will not share utilities, traffic, construction plans, Stormwater Pollution Prevention Plans, or end users. Both are Type I projects, and any environmental impacts of the Fieldhouse project that the City and Town Planning Boards are reviewing through the current coordinated review will not be artificially reduced by Cornell’s change in plans, nor compounded through a segmented review. Second, although Cornell owns both project locations, the two locations are in different municipalities and completely separated by nearly 1.5 miles. See Friends of Stanford Home v. Town of Niskayuna, 50 A.D.3d 1289, 1291 (3d Dep’t 2008) (affirming a finding of permissible segmentation where two projects were located a mile apart and not part of a common design). The City Planning Board has no discretionary decisions to make regarding a field hockey development at Game Farm Road. Because of that lack of jurisdiction, the City Planning Board would not be an involved agency for the field hockey development and coordinated review would not be appropriate. The environmental review required by SEQRA will be best accomplished by the Town Planning Board serving as the lead agency and applying its knowledge and familiarity of the Game Farm Road site, Town-specific environmental and utility concerns, and other relevant factors. Third, the City Planning Board’s review and anticipated approval of the Fieldhouse project does not commit the Town of Ithaca Planning Board to approve the construction of the field hockey field. The Town Planning Board will be free to take the required “hard look” at any issues raised by the proposed field hockey development and make its own determination of the significance of that project’s environmental impact. See Saratoga Springs Preservation Foundation v. Boff, 110 A.D.3d 1326, 1328 (3d Dep’t 2013) (upholding segmented environmental review where review of future construction would ensure environment would not be less protected as a result). Cornell requests that the City Planning Board make clear at this time that any segmentation required is permissible under state law, in order to permit the coordinated environmental review of the Meinig Fieldhouse project to continue, and for Cornell to submit the field hockey project for review and approval separately by the Town of Ithaca. Sincerely, Kimberly Michaels Director of Landscape Architecture Appendix B: Cornell University Energy Strategy Letter Sarah Carson Director Campus Sustainability Office 129 Humphreys Service Building Ithaca, New York 14853-3701 t.(607) 254-2818 e.sc142@cornell.edu February 2. 2024 Dear City and Town of Ithaca Planning Boards, This letter is intended to clarify Cornell University’s strategy for achieving its longstanding goal of campus carbon neutrality by 2035 and the requirements of the Ithaca Energy Code Supplement (IECS) Renewable Energy section for individual building projects , toward our shared decarbonization goals. Renewable energy production (REP) required to satisfy portions of the IECS renewable energy credits for the Meinig Fieldhouse will be allocated from the University’s existing renewable energy portfolio. At this time, the university receives qualifying REP from the following assets where the University has worked with development partners to create new renewable energy assets : •2.8MWdc Cornell University Ruminant Center Solar Farm – Harford, NY •5.7MWdc Cornell University Agricultural Experiment Station Solar Farm – Ledyard, NY •2.8MWdc Cornell University NYS Agricultural Experiment Station S olar Farm – Geneva, NY •26.5MWdc Cascadilla Community Solar Farm at Cornell – Ithaca, NY When considered in a campus context, the capacity for installation of solar equipment on individual building rooftops for specific projects is often mismatched with the IECS REP requirement, and must be supplemented. The University will continue to invest in larger scale renewable energy projects to increase our renewable energy portfolio at a district scale. Ground-mount solar energy systems presently yield more electrical generation per dollar spent. They also offer more robust opportunities to use our campus as a living laboratory to develop and demonstrate co-benefits of renewable energy development to help address the challenges facing deployment of renewables at scale, state -wide. Therefore, the University plans to focus investment on these types of projects. The Meinig Fieldhouse will be constructed as a solar-ready facility. This pre-positions the facility for the possible addition of solar renewable energy systems by providing interior electrical pathways, structural design capacity within the building framing to support roof loads associated with solar panel equipment, and space within electrical rooms for future equipment installation. This allows for the Fieldhouse to be aggregated into a larger pool of available project-ready sites in the future. Sincerely, Sarah Carson Appendix C: Synthetic Turf Information Letter, Haley and Aldrich H & A OF NEW YORK ENGINEERING AND GEOLOGY, LLP 213 W. 35th Street 7th Floor New York, NY 10001 646.277.5685 www.haleyaldrich.com 2 April 2024 File No. 204866-000 TO: Sasaki Trey Sasser, PE FROM: H & A of New York Engineering and Geology, LLP Jay Peters, Principal, Risk Assessment Scott Goldkamp, Principal Subject: Evaluation of Health and Environmental Effects: Synthetic Turf Indoor Sports and Recreation Center & Multipurpose Field Cornell University Ithaca, New York The purpose of this H & A of New York Engineering and Geology, LLP (Haley & Aldrich of New York) memorandum is to provide a summary of recently published studies and reports that evaluate the safety (health and environmental risks) of using synthetic turf athletic fields, with focus on chemicals contained in or associated with synthetic turf. There are approximately 13,000 synthetic turf athletic fields in the United States and more than 1,200 are being added each year. Similarly, the European Chemicals Agency (ECHA) estimates that there are 13,000 large synthetic turf fields in the European Union. There are no state or federal laws that prohibit installation of synthetic turf fields. A synthetic turf field consists of three main components, including turf blades (the portion of the system that mimics grass blades), a backing material that holds the turf blades in place (similar in concept to backing material that holds household carpet together), and an infill material. The purpose of the infill material is to keep the grass blades standing “up”, provide cushioning for the system, and provide appropriate foot to surface interaction (e.g., traction) as well as feeling underfoot (e.g., soft versus firm). Turf blades and backing material are typically made from polyethylene and/or polypropylene (plastic family). Infill is comprised of a mixture of sand and rubber. Two synthetic turf fields are proposed for installation at the Cornell University Indoor Sports and recreation Center and Alumni Field:  An outdoor field and indoor field will contain an infill comprised of sand and either recycled crumb rubber or a virgin synthetic rubber. Sasaki 2 April 2024 Page 2 The Town of Ithaca Conservation Commission – Environmental Review Board, raised concerns about the potential emissions and impacts from crumb rubber infill, including heat emitted by the field. Crumb rubber, also referred to as recycled crumb rubber / ambient rubber, consists of small rubber fragments (between 0.25 and 4 millimeters in diameter) that are created by recycling tires. There has been a lot of focus on crumb rubber as an infill material, primarily due to allegations in 2014 by the University of Washington women’s soccer team that exposure to crumb rubber is associated with higher rates of cancer. However, evaluation of those allegations by the Washington Department of Public Health as well as researchers (e.g., Bleyer et al., 2018) determined that there is no link between use of synthetic turf fields with crumb rubber infill and increased incidence of cancer. In addition, attention has been drawn to crumb rubber infill over concerns about release of emissions to the air, and release of chemicals to the environment through infiltration of rainwater that passes through the synthetic turf system and into storm water that is eventually conveyed to surface water. Finally, concerns have been raised about heat retention and emission of synthetic turf fields that use crumb rubber infill. Synthetic rubber (ethylene propylene diene monomer [EDPM]) can be used as a substitute for crumb rubber. EDPM as a synthetic fill is supplied by several manufacturers, including TTII PLAY-SAFE 65 EPDM Infill, which is being considered for this project. The following content in this memorandum addresses potential health and environmental effects associated with synthetic turf field system components, with a focus on crumb rubber and EDPM infill, and a focus on the shock pad, backing, and turf blade components. A substantial amount of information exists on the internet concerning the makeup of synthetic turf and its intersection with children, athletes, and the environment. When evaluating that information, it is important to focus on scientific studies that are peer reviewed. Scientific studies seek to resolve questions using carefully documented methods and procedures, with results that are evaluated using widely accepted statistical and other techniques. Studies that are peer reviewed ensure that the methodologies used for the studies are appropriate and valid, that the findings are interpreted using appropriate approaches, and that the conclusions are supported by the data developed in the study. A key aspect of a peer reviewed scientific study is that the study provides detailed documentation that would allow an independent party to repeat the study and verify the results. For these reasons, peer reviewed scientific studies were used to support the conclusions developed in this memorandum. EVALUATION OF CHEMICALS AND HEALTH AND ENVIRONMENTAL EFFECTS ASSOCIATED WITH CRUMB RUBBER AND EDPM INFILL Most of the studies on synthetic turf are specifically related to concerns about contact with crumb rubber infill. Over 100 scientific, peer-reviewed, published studies have been performed worldwide evaluating the potential health risks associated with turf fields that use crumb rubber. We are not aware of any peer-reviewed scientific studies which draw an association between adverse health effects and use of crumb rubber. Similarly, the New York State Department of Health concluded that synthetic turf fields that use crumb rubber infill pose a low concern regarding health risks (NYSDOH, 2018). We have reviewed recent studies and reports that have evaluated whether chemicals contained in crumb rubber have the potential to cause adverse health effects from contact with the crumb rubber. Sasaki 2 April 2024 Page 3 Contact with crumb rubber can occur when the rubber particles stick to the skin, or when they are accidentally ingested (e.g., through field play that involves body contact with the turf). However, exposure to chemicals present in the rubber requires that the chemicals come out of the rubber (e.g., leached out by stomach acid if ingested, or leached out through sweat for particles that stick to the skin). The following studies were conducted by extracting crumb rubber samples from playing fields in fluids that simulate sweat and gastric fluid and analyzing the extracts for metals and organic chemicals. Conclusions from these studies are as follows:  Pavilonis et al. (2014). The researchers concluded that health risks associated with use of synthetic turf fields with crumb rubber infill were orders of magnitude below regulatory levels used to define safety thresholds.  Peterson et al. (2018). The results of the study showed that cancer risks for use of synthetic fields were below the US Environmental Protection Agency (EPA) de minimis risk level of 1x10-6, and that risks for health effects other than cancer were below the EPA threshold value of 1. Furthermore, the evaluation showed that risks estimated for use of synthetic turf fields are lower than risks estimated for natural turf fields which contain ambient background levels of metals and polyaromatic hydrocarbons (PAHs) in the soil.  Schneider et al. (2020). The study concluded that estimated risks for use of synthetic turf fields with crumb rubber infill were below guidelines used by both the European Union and the EPA.  Pronk, eta al. (2020). The study concluded that chemical concentrations in crumb rubber infill complied with concentration limits set for mixtures of substances in Europe, and that health risks were below regulatory guidelines. In addition, EPA (2019) collected crumb rubber from 9 tire recycling facilities, 15 indoor turf fields and 25 outdoor turf fields from throughout United States and analyzed the samples SVOCs, metals, and microbes. The study also measured the bioavailable fraction of metals in the samples and the emissions of VOCs at both 77- and 140-degrees F. Key findings from the study are:  Metals and SVOC concentrations were similar to those reported in other studies that examined the chemical content of crumb rubber.  Emissions of VOCs were generally not detectable at 77F. Emissions of some VOCs increased slightly at 140F. Nevertheless, even at 140F, emissions were very low.  Approximately 3% of the concentrations of metals were estimated to be bioavailable if the crumb rubber is ingested, and less than 1% were estimated to be bioavailable if the crumb rubber sticks to skin and the metals transfer from the rubber through the skin.  The type and number of bacteria in samples of crumb rubber were similar to those present in environments where synthetic turf is not present. The report cited literature indicating that crumb rubber infill harbors fewer bacteria than natural turf. The following tables provide comparisons of the 90th percentile concentrations of metals and organic chemicals detected in the crumb rubber collected from the turf fields to the New York Soil Cleanup Objectives (SCOs) applicable to soil in residential yards (6 CRR-NY 375-6.8NY-CRR). When SCOs were unavailable, the EPA Regional Screening Levels were used (EPA, 2023a). The SCOs are standards that are Sasaki 2 April 2024 Page 4 used to determine if chemical concentrations in soil are safe (i.e., would not pose a health risk concern) and are protective for children contacting soil through play, and adults contacting soil through yard work. In addition, SCOs and RSLs that are protective for migration of constituents from soil to groundwater that is used as drinking water were also used. Sasaki 2 April 2024 Page 5 The 90th percentile concentrations of the majority of metals and organic chemicals detected in crumb rubber are below the screening levels. Exceptions to this include cobalt, zinc, benzo(a)pyrene, and aniline. The same comparisons were completed for EDPM samples, using analytical data developed by an independent testing laboratory (Labosport). As indicated in the tables below, the majority of metals and organic chemicals analyzed in the EDPM samples were not detected, and the reporting limits (lowest concentrations that can be reliably measured by the analytical equipment) are below the screening levels. The two metals and five organic chemicals that were detected, were reported at concentrations well below the screening levels. Sasaki 2 April 2024 Page 6 It is important to note that the analytical results and comparisons to screening levels presented for crumb rubber and EDPM do not account for the portion of metals and organic chemicals that may leach out and be available for exposure. EPA (2019) concluded that only 3% of the metal concentrations reported in the crumb rubber samples are available for exposure. This suggests that the concentrations of cobalt, zinc, benzo(a)pyrene, and aniline that exceeded the screening levels would not pose risks of concern. The analytical results for the EDPM samples indicate that use of EDPM as infill material would pose no risks of concern for contact with the infill and would pose no risks of concern for potential leaching of metals and organic chemicals and subsequent migration to groundwater. The information provided by these studies demonstrate that the chemicals that are in crumb rubber infill are unlikely to come out of the materials at concentrations that would harm people or the environment. By comparison chemicals are present at lower concentrations in EDPM and would not come out at concentrations that would harm people or the environment. Consequently, rubber infills are safe for contact by people and will not harm groundwater or surface water. Sasaki 2 April 2024 Page 7 EVALUATION OF CHEMICALS AND HEALTH AND ENVIRONMENTAL EFFECTS ASSOCIATED WITH SHOCK PAD, BACKING, AND BLADES Since the potential for adverse health effects from playing on synthetic turf fields is low, as described previously, and the studies evaluating those effect included exposure to the whole turf field system (backing, blades, and infill), it is reasonable to conclude that the shock pad, backing, and turf blades would also not cause adverse health effects. Historically, some older synthetic turf blades contained lead. Synthetic turf now needs to comply with consumer product safety requirements, which means that turf blades no longer contain lead. Information is available on the chemicals present in synthetic turf system components from two recent studies, which are described below. Tetra Tech (2021) Tetra Tech evaluated the chemical composition of a synthetic turf system which specified a polyethylene carpet with a woven backing over a polypropylene pad and using sand and an organic infill (Brockfill which is comprised of material derived from a specific pine tree). A significant aspect of the Tetra Tech study is that it evaluated each of synthetic turf system components for chemicals that have historically been evaluated in crumb rubber infill (e.g., metals and polycyclic aromatic hydrocarbons [PAHs]), as well as per- and poly-fluoralkyl substances (PFAS). It is important to note that this study was peer reviewed by the Horsley Witten Group. The evaluation included chemical analyses of each turf system component (turf carpet, shock pad, glue and bonding agents, and infill) for semi-volatile organic compounds (SVOCs), metals, and PFAS compounds. Testing was also performed to evaluate both total and leachable concentrations of these chemicals. The analytical results were used in a risk assessment to evaluate possible pathways for migration of chemicals to the environment, potential exposure to human and environmental receptors, and possible health and environmental risks. The risk assessment was completed by comparing detected concentrations to standards and screening levels that are protective for exposure to soil in a residential yard setting (i.e., high frequency contact by toddlers, young children, adolescents and adults), and protective for migration to groundwater that is used as drinking water. Based on the results of the risk assessment, Tetra Tech concluded that:  Concentrations of metals were similar to or less than those that naturally occur in soil and were below standards and screening levels.  Most SVOCs were not detected, and those that were detected were below standards and screening levels.  None of the PFAS compounds regulated by the State of New York were detected. Two PFAS compounds (PFPeA and 6:2FTS) that are not regulated by New York were detected in synthetic turf system samples at low (estimated) concentrations that were also below available standards published for other PFAS compounds. Sasaki 2 April 2024 Page 8  None of the compounds analyzed were detected at concentrations that would pose a concern for leaching to groundwater. The Tetra Tech report evaluated 29 PFAS compounds and also evaluated PFAS using a procedure which evaluates the potential for transformation of a certain class of PFAS compounds (known as precursors) into other PFAS compounds, to mimic conditions that could hypothetically occur under some environmental conditions. The results of the procedure indicated that two additional PFAS compounds (PFHpA and PFBA) could be generated through transformation of PFAS precursor compounds. Neither of these compounds are regulated by the State of New York. However, the leachable concentrations measured in the leaching study were below the concentrations that are protective for drinking water issued by other states. Since the results of the Tetra Tech report indicate that the synthetic turf system would not pose any significant risks to human health or the environment, it can be concluded that turf carpeting and bonding agents alone would not pose any significant risks. TRC Companies (2022) TRC conducted a study to evaluate whether a synthetic turf system that had already been installed contained PFAS. TRC tested the turf carpet, shock pad, and infill. The infill used in the project was an organic material (US Greentech Safeshell Infill). The turf system components were analyzed for 70 PFAS compounds. The study found that five PFAS compounds that are unregulated by the State of New York were detected at low concentrations. TRC also evaluated PFAS using a procedure which evaluates the potential for transformation PFAS into other PFAS compounds, to mimic conditions that could hypothetically occur under some environmental conditions. Several additional PFAS compounds were detected after the oxidizing procedure, but all at concentrations well below available screening levels that are protective for exposure to soil in a residential yard setting (i.e., high frequency contact by toddlers, young children, adolescents and adults). Based on the evaluation, TRC concluded that the synthetic turf system did not pose any health risks of concern from PFAS. SOURCES OF PFAS IN THE ENVIRONMENT PFAS has been used in numerous consumer products, including cosmetics, sunscreen, non-stick cookware, waterproof shoes and clothing, and stain-resistant furniture and carpeting. It has also been used in manufacturing for its surfactant properties and in firefighting foam used to suppress petroleum fires (ITRC, 2022). Due to its widespread use over the past 50+ years, PFAS is present in the environment (soil, surface water, groundwater, air, and even rainwater) as a background condition. In fact, the states of Maine and Vermont have each conducted studies of the PFAS concentrations that exist as a background condition in soil. In both studies, PFAS was detected in nearly all of the 60-plus soil samples collected from each state. The background studies demonstrate that PFAS is a ubiquitously present in surface soil. The sources of the PFAS in surface soil are likely due to atmospheric deposition through PFAS in the air and PFAS in rainwater. PFAS is not a chemical that is added to synthetic turf components, nor is it used to manufacture tires which are recycled to create crumb rubber. Therefore, there is no reason to suspect that it would be Sasaki 2 April 2024 Page 9 present in synthetic turf carpeting or crumb rubber infill at anything other than negligible concentrations. Evaluation of the PFAS detected in the Tetratech (2021) and TRC (2022) studies indicate that fewer PFAS compounds were detected in synthetic turf, and at lower concentrations, than those that are present as a background condition in soil. The information provided by these studies demonstrate that the chemicals that are in the synthetic turf cannot come out of the materials at concentrations that would harm people or the environment. Consequently, synthetic turf systems are safe for contact by people and will not harm groundwater or surface water. EVALUATION OF “HEAT ISLAND” AND SYNTHETIC TURF A Heat Island is an area where the temperature is higher than in the surrounding area. Heat Islands are caused by reduced natural landscape in urban areas, the properties of urban materials (pavement, roofing, aggregate-based building materials), urban geometry (dimensions and spacing of buildings which can trap heat), heat generated by human activities (e.g., automobiles, air conditioning), and weather and geography. In particular, the combination of urban materials and urban geometry can create large thermal masses that cannot easily release heat. According to the USEPA (2023b), Heat Islands often build throughout the day and become more pronounced at night due to the slow release of heat from urban materials. The surfaces of synthetic turf fields get warmer than the surfaces of natural turf fields. However, the differences in temperatures vary depending on weather conditions (e.g., sunny versus cloudy) and time of day. Several studies have examined the differences in heating between synthetic turf fields and natural turf fields. A comprehensive study by Jim et al. (2017) indicates that:  On sunny days, surface temperatures of synthetic turf fields can be 30 to 40 degrees C higher than surfaces of natural turf fields. On cloudy days (defined as days when cloud cover reduced solar radiation to approximately one-half that of sunny days) surface temperatures of synthetic turf fields may be approximately 20 degrees C higher than natural turf fields, and on overcast days (defined as days when cloud cover reduced solar radiation to approximately one-quarter that of sunny days) there is essentially no difference in field surface temperatures.  Despite substantial surface temperature differences between synthetic and natural turf fields on sunny days, there is only a few degrees (centigrade) difference in air temperature between synthetic turf and natural turf fields at 20 inches and 40 inches above the playing field surface, and essentially no difference in air temperature at 60 inches above the field surfaces. This difference becomes smaller as daytime heating increases, with 20- and 40-inch air temperatures above synthetic turf nearly equaling those above natural turf during the afternoon hours. On cloudy and overcast days there is essentially no difference in air temperatures between synthetic turf and natural turf fields at 20- and 40-inches above the playing field surfaces.  Synthetic turf surfaces and the air above synthetic turf fields heats and cools more rapidly than those associated with natural turf.  The solar radiation released by natural and synthetic turf fields during nighttime is the same, meaning that that synthetic turf does not ‘hold heat’ and release it after sunset. This Sasaki 2 April 2024 Page 10 observation reflects that fact that synthetic turf has a poor heat storage capacity, which is reflected in the rapid changes in surface temperature profiles of synthetic turf as compared to natural turf, and the observation that synthetic turf surfaces return to the same temperature as natural turf surfaces when solar radiation is reduced (e.g., late afternoon/evening on sunny days and the duration of the day on overcast days). One of the reasons that synthetic turf surfaces get hotter than natural turf surfaces is due to the common use of infill materials that absorb heat from solar radiation. Since the synthetic turf field proposed for field hockey use will not contain infill, it is anticipated that surface temperatures of the field will be lower than those typically associated with synthetic turf fields. Collectively, this information suggests that, while synthetic turf field surfaces get warmer than natural turf field surfaces, air temperatures above synthetic turf surfaces warm only marginally more than those above natural turf field surfaces, and that synthetic field surfaces do not retain heat once daytime heating is discontinued. These differences are substantially minimized on cloudy days and do not exist on overcast days. In that respect, synthetic turf fields are different than urban systems (aggregate buildings, roof tops, and pavement) which are associated with contributing to Heat Island effects which by the nature of those materials continue to release heat well into the nighttime hours. References 1. Bleyer, Archie, and Theresa Keegan. 2018. “Incidence of Malignant Lymphoma in Adolescents and Young Adults in the 58 Counties of California with Varying Synthetic Turf Field Density.” Cancer Epidemiology 53 (April): 129–36. https://doi.org/10.1016/j.canep.2018.01.010. 2. Interstate Technology Regulatory Council (ITRC). 2022. PFAS Technical and Regulatory Guidance Document. Updated June 2022. https://pfas-1.itrcweb.org/ 3. Jim, C. Y. 2017. “Intense Summer Heat Fluxes in Artificial Turf Harm People and Environment.” Landscape and Urban Planning 157 (January): 561–76. https://doi.org/10.1016/j.landurbplan.2016.09.012. 4. Pavilonis, Brian T., Clifford P. Weisel, Brian Buckley, and Paul J. Lioy. 2014. “Bioaccessibility and Risk of Exposure to Metals and SVOCs in Artificial Turf Field Fill Materials and Fibers.” Risk Analysis 34 (1): 44–55. https://doi.org/10.1111/risa.12081 5. Peterson, Michael K., Julie C. Lemay, Sara Pacheco Shubin, and Robyn L. Prueitt. 2018. “Comprehensive Multipathway Risk Assessment of Chemicals Associated with Recycled (“crumb”) Rubber in Synthetic Turf Fields.” Environmental Research 160: 256-268 https://pubmed.ncbi.nlm.nih.gov/29031215/ 6. Pronk, Marja E. J., Marjolijn Woutersen, and Joke M. M. Herremans. 2020. “Synthetic Turf Pitches with Rubber Granulate Infill: Are There Health Risks for People Playing Sports on Such Pitches?” Journal of Exposure Science & Environmental Epidemiology 30 (3): 567–84. https://doi.org/10.1038/s41370-018-0106-1. 7. Schneider, Klaus, Anne Bierwisch, and Eva Kaiser. 2020. “ERASSTRI - European Risk Assessment Study on Synthetic Turf Rubber Infill – Part 3: Exposure and Risk Characterisation.” Science of The Total Environment 718 (May): 137721. https://doi.org/10.1016/j.scitotenv.2020.137721. 8. Tetra Tech. 2021. Synthetic Turf Laboratory Testing and Analysis Summary Report, Martha’s Vineyard Regional High School Athletic Fields Project (DRI 352-M4) Oak Bluffs, Massachusetts. https://www.oakbluffsma.gov/DocumentCenter/View/7435/TetraTech-MVC-2021-02-26- TurfAnalysisReport_FINAL 9. TRC, 2022. Evaluation of PFAS in Synthetic Turf. Technical Memorandum from Elizabeth Denly, TRC Vice President and Dr. Karen Vetrano, TRC Risk Assessment and Toxicology Manager, to Peter H. Rice, Directory of Public Works and Suzanne Woodland, Deputy City Attorney. June 7. https://www.cityofportsmouth.com/sites/default/files/2022- 06/Technical%20Memorandum_Portsmouth_Final.pdf 10. US EPA, Office of Research and Development. 2019. “July 2019 Report: Tire Crumb Rubber Characterization.” Reports and Assessments. US EPA. July 24, 2019. https://www.epa.gov/chemical-research/july-2019-report-tire-crumb-rubber-characterization-0 11. US EPA, 2023a. Regional Screening Levels. November, 2023. https://www.epa.gov/risk/regional- screening-levels-rsls-generic-tables 12. US EPA, 2023b. “Learn About Heat Islands” https://www.epa.gov/heatislands/learn-about-heat- islands \\haleyaldrich.com\share\CF\Projects\0204866\Deliverables\Synthetic Turf Opinion\2024 0402-HAI Cornell Synthetic Turf Memo_F.docx Appendix D: Synthetic Turf Public Comment Response Letter 110 Chauncy Street, Suite 200 Boston, MA 02 111 USA p 617 926 3300 f 617 924 2748 www.sasaki.com 9 April 2024 Kimberly Michaels, RLA, LEED AP Fisher Associates, P.E., L.S., L.A., D.P.C. 1001 West Seneca Street, Suite 201 Ithaca, New York 14850 Dear Kim, Based on questions, comments, and concerns from the recent public meetings for the proposed synthetic turf at Cornell University’s Indoor Sports & Recreation Center & Multi-purpose Field, please see responses below from Sasaki Associates and attached Memo titled, “Evaluation of Health and Environmental Effects: Synthetic Turf Indoor Sports and Recreation Center & Multipurpose Field” dated 2 April 2024 from Haley & Aldrich New York Engineering and Geology, LLP for further information. Excerpts from Memo used to answer some of the questions/concerns below. PUBLIC COMMENTS FROM COI PUBLIC HEARING ON FEBRUARY 27, 2024 1. The plastic turf pollutes and poisons with toxins throughout its lifecycle, from extraction, transportation, manufacturing, usage, and disposal at the end of its life. a. RESPONSE: We are not aware of research indicating that synthetic turf pollutes throughout its lifecycle. The information provided in the memorandum indicates that synthetic turf systems, when in use as play surfaces, do not cause adverse effects to human health or the environment (soil, groundwater, surface water, atmosphere). The Pavilonis et al. (2014), Peterson et al. (2018), Schneider et al. (2020), Pronk, et al. (2020) peer-reviewed studies determined that estimated health risks were below regulatory levels used to define safety thresholds by the EPA and European Union. Emissions of VOCs (volatile organic compounds) from synthetic turf into the atmosphere were generally not detectable at 77F, and only increased slightly at 140F, as determined by the EPA (2019) study. 2. Plastic turfs are not being recycled and are extremely difficult to recycle. a. RESPONSE: The synthetic turf, inclusive of turf blades and infill, will be recycled after its life cycle of 8-12 years. The performance shock pad can be used for at least two synthetic turf cycles, before being recycled. 110 Chauncy Street, Suite 200 Boston, MA 02111 USA p 617 926 3300 f 617 924 2748 www.sasaki.com 3. In January 2023, the Governor of New York signed bill S834-2023 into law, prohibiting the sale of carpets, including artificial turfs, containing PFAS chemicals. As artificial turf often contain PFAS, this law effectively bans their sale and installation in New York State. a. RESPONSE: There are no state or federal laws that prohibit installation of synthetic turf fields. PFAS is not a chemical that is incorporated into the manufacture synthetic turf components, nor is it used to manufacture tires which are recycled to create crumb rubber. 4. The concept of PFAS-free turf is questionable. From discussions with experts in our anti-turf coalition, we have a consensus that there is no truly PFAS-free turf. a. RESPONSE: PFAS is not a chemical that is added to synthetic turf components, nor is it used to manufacture tires which are recycled to create crumb rubber. Therefore, there is no reason to suspect that it would be present in synthetic turf carpeting or crumb rubber infill at anything other than negligible concentrations. Evaluation of the PFAS detected in the Tetratech (2021) and TRC (2022) studies indicate that fewer PFAS compounds were detected in synthetic turf, and at lower concentrations, than those that are present as a background condition in soil. 5. Is artificial turf truly fireproof? What chemicals is it treated with to make it fireproof? Are those chemicals released into the air or soil over time? a. RESPONSE: Synthetic turf is widely accepted and used across the country, even in wildfire-prone areas such as California. Artificial turf is tested to be fireproof when a sand-based infill is applied with the turf. The exterior multi-purpose field and interior synthetic turf field will be installed with this sand-based infill. No chemicals are used in the treatment of synthetic turf to make it fireproof. 6. How well does artificial turf hold up over time? Does exposure to UV break down plastics? Damaged plastics are hard to eradicate. a. RESPONSE: Synthetic turf systems are designed to be used for 8-12 years, after which they are recycled. The EPA (2019) study and analytical data from Labosport concluded that none of the metal or organic compounds found in the crumb rubber or synthetic turf samples posed risks of concern. 7. What about drainage? Will water pool on the turf? 110 Chauncy Street, Suite 200 Boston, MA 02111 USA p 617 926 3300 f 617 924 2748 www.sasaki.com a. RESPONSE: Water infiltrates synthetic turf fields through the fibers and infill and into the stone base below and then into the stormwater system. 8. Covering a field with artificial turf will change water drainage patterns and affect other buildings and soil. a. RESPONSE: While water drainage patterns will change through the implementation of the proposed site changes, there will not be significant adverse impacts to the soil condition or surrounding buildings. Hydrologic and hydraulic analysis has been conducted by a licensed civil engineer to ensure that post-development flow rates of stormwater runoff existing on the site do not increase from existing conditions. Drainage design on the site has ensured that stormwater runoff will not cause adverse impacts to surrounding buildings for all design storm conditions. The existing conditions on Alumni Fields includes a large stormwater subgrade system that lies directly below the existing field. 9. The soil will die from lack of water, the heat buildup under the turf, and the lack of light. Won’t the stadium become very hot as turf traps heat? a. RESPONSE: While synthetic turf field surfaces get warmer than natural turf field surfaces, air temperatures above synthetic turf surfaces warm only marginally more than those above natural turf field surfaces, and that synthetic field surfaces do not retain heat once daytime heating is discontinued. These differences are substantially minimized on cloudy days and do not exist on overcast days. In that respect, synthetic turf fields are different than urban systems (aggregate buildings, roof tops, and pavement) which are associated with contributing to Heat Island effects which by the nature of those materials continue to release heat well into the nighttime hours. 10. Do players prefer grass to plastic? Won’t they be injured more by sliding on plastic rather than grass? a. RESPONSE: Players prefer to have fields with surfaces that are playable, even, and safe. Fields should meet the Performance Test Standards for both Skin/Surface Friction and Skin Abrasion including FIFA test method 08 “Determination of Skin/Surface Friction” and ASTM F1015 “Relative Abrasiveness of Synthetic Turf Playing Surfaces”. 110 Chauncy Street, Suite 200 Boston, MA 02111 USA p 617 926 3300 f 617 924 2748 www.sasaki.com TOI CONSERVATION BOARD MEMO TO TOI PLANNING BOARD (JANUARY 31, 2024) 1. The impact on our local environment with the leaching of contaminants into our air, water, and soil. The impact on human health with the exposure to toxic material and physical injuries to athletes. a. RESPONSE: Please refer to the response to Comment 1 of “PUBLIC COMMENTS FROM COI PUBLIC HEARING ON FEBRUARY 27, 2024”. 2. Effect of extreme heat emitted from fields during hot weather periods, both at ground level and “head level” (and perhaps beyond). If a field is located in a low-lying area, with barriers like hillsides or buildings around it, that could create serious problems for people on the field and around it, as well as for plants and animals. a. RESPONSE: While synthetic turf field surfaces get warmer than natural turf field surfaces, air temperatures above synthetic turf surfaces warm only marginally more than those above natural turf field surfaces, and that synthetic field surfaces do not retain heat once daytime heating is discontinued. These differences are substantially minimized on cloudy days and do not exist on overcast days. In that respect, synthetic turf fields are different than urban systems (aggregate buildings, roof tops, and pavement) which are associated with contributing to Heat Island effects which by the nature of those materials continue to release heat well into the nighttime hours. 3. Might Cornell define a monitoring and research plan that will advance the understanding and motivate innovation in artificial turf that makes it a truly “green” alternative? a. RESPONSE: Cornell is a global leader in sustainability, and climate change research, teaching, and engagement. As a leader in green alternatives, Cornell has been working on ways in which to advance and monitor material development in all industries. Our campuses are living laboratories for developing, testing, and implementing solutions that address these most challenging issues. There are more than 100 majors, minors, and concentrations focused on sustainability. 4. Since crumb rubber and other components of artificial turf degrade upon exposure to sunlight, air, and water, they will be disposed of within 10-20 years. What is the composition of the materials at the end of their life? Will the materials be hazardous waste? a. RESPONSE: The chemical composition of crumb rubber at the end of its life is very similar to the composition when it is first used. Although some of the most volatile chemicals may be slowly released 110 Chauncy Street, Suite 200 Boston, MA 02111 USA p 617 926 3300 f 617 924 2748 www.sasaki.com from crumb rubber over time, the other chemicals in crumb rubber are only transformed or released from UV decomposition of tire rubber when combined with other processes that are not natural (e.g., catalysts, high heat, or pressure) (as indicated in the memorandum, even fresh crumb rubber does not release volatile chemicals at levels that would pose a health concern). In fact, there is recent research indicating that use of recycled rubber in pavement prolongs the life of the pavement, primarily by making the pavement more resistant to UV degradation. Tires, as well as crumb rubber and aged tires or crumb rubber, are not considered hazardous waste. 5. Is the applicants plan that with the synthetic turf field relocation the current synthetic turf field materials will go to a landfill? a. RESPONSE: The synthetic turf materials including turf fibers and infill will be recycled at the end of its’ useful life about 8-12 years after installation. The performance shock pad will be used for at least two turf cycles. 6. Is Cornell a leader in identifying an innovative solution to the disposal of their artificial turf components during this project and when the updated turf field reaches the end of its life within 10-20 years. a. RESPONSE: Please refer to the response to Comment 3 of “TOI CONSERVATION BOARD MEMO TO TOI PLANNING BOARD (JANUARY 31, 2024)”. CITY OF ITHACA PLANNING BOARD MEETING (JANUARY 23, 2024) 1. What happens when it needs to be replaced? Is it recyclable? a. RESPONSE: The synthetic turf materials including turf fibers and infill will be recycled at the end of its’ useful life about 8-12 years after installation. The performance shock pad will be used for at least two turf cycles. 2. How is it maintained? a. RESPONSE: Maintenance activities on the synthetic turf surfaces seek to provide consistent, safe playing surfaces and are carried out by Cornell’s staff as well as the turf manufacturer’s regional service provider. Regular inspections check that seams are tight and level, surfaces are free of debris, and infill depth is correct and consistent. Field grooming is completed as necessary, typically three to six times per year, to alleviate compaction, redistribute and level infill, and correct fiber layover. During grooming, a magnet is dragged over the surface to remove metal objects. 110 Chauncy Street, Suite 200 Boston, MA 02111 USA p 617 926 3300 f 617 924 2748 www.sasaki.com 3. How often is it replaced/does it wear out? a. RESPONSE: A synthetic turf field is replaced at the end of its’ useful life, approximately every 8-12 years. Sincerely, Trey Sasser, PE Senior Associate Appendix E: Vehicle Tracking Study ALUMNI FIELD PARKING LOT INDOOR SPORTS & RECREATION CENTER FFE 878.33 PARKING LOT CHARLES F. BERMAN FIELDILL ALL FIELD EL. 875 ALUMNI FIELD ACCESS FROM CAMPUS ROAD ACCESS FROM TOWER ROAD VEHICULAR ACCESS TO FIELD ACCESS FROM CAMPUS ROAD ACCESS FROM TOWER ROAD ACCESS FROM TOWER ROAD Stamp Project Directory: Drawing No. Drawing Title: Key Plan Project Title: Scale:Project No: Drawn By: Checked By: Approved By: Date: ARCHITECT + LANDSCAPE ARCHITECT SASAKI 110 Chauncy Street Boston, MA 02111 TEL. 617.926.3300 www.sasaki.com CIVIL TG MILLER 605 West State Street, Suite A Ithaca, NY 14850 TEL. 607.272.6477 www.tgmillerpc.com STRUCTURAL LEMESSURIER 1380 Soldiers Field Road Boston, MA 02135 TEL. 617.868.1200 www.lemessurier.com MEP/FP RFS ENGINEERING 71 Water Street Laconia, NH 03246 TEL. 603.524.4647 www.rfsengineering.com BUILDING AND FIRE CODE HOWE ENGINEERS 141 Longwater Drive, Suite 110 Norwell, MA 02061 TEL. 781.878.3500 www.howeengineers.com NOT FO R C O N S T R U C TI O N North VEHICLE TRACKING STUDY 28020.00 AR 1" = 20' 3/20/2023 Cornell University TRUCK BODY TRUCK CHASSIS JP AG CROSS HATCHED AREA IS FOR PEDESTRIANS OR LIGHT VEHICLE TRAFFIC ONLY FIRE HYDRANT LOCATIONS ADJACENT TO NE AND SE CORNERS OF BUILDING. - A FREE STANDING BUILDING FIRE DEPARTMENT CONNECTION WILL BE LOCATED ADJACENT TO BOTH HYDRANTS. - A BUILDING SPRINKLER ALARM BELL AND FIRE ALARM STROBE LIGHT WILL BE LOCATED ON BOTH NORTH AND SOUTH SIDES OF THE BUILDING NEAR THE HYDRANTS AND FIRE DEPARTMENT CONNECTIONS. BUILDING NORTH ENTRY: - DESIGNATED AS FIRE DEPARTMENT MAIN ENTRY POINT. - ENTRY VESTIBULE WILL CONTAIN MAIN FIRE ALARM SYSTEM PANEL BUILDING SOUTH ENTRY: - ENTRY VESTIBULE WILL CONTAIN REMOTE FIRE ALARM SYSTEM PANEL ALUMNI FIELD PARKING LOT INDOOR SPORTS & RECREATION CENTER FFE 878.33 PARKING LOT CHARLES F. BERMAN FIELDILL ALL FIELD EL. 875 ALUMNI FIELD ACCESS FROM CAMPUS ROAD ACCESS FROM TOWER ROAD VEHICULAR ACCESS TO FIELD ACCESS FROM CAMPUS ROAD ACCESS FROM TOWER ROAD Stamp Project Directory: Drawing No. Drawing Title: Key Plan Project Title: Scale:Project No: Drawn By: Checked By: Approved By: Date: ARCHITECT + LANDSCAPE ARCHITECT SASAKI 110 Chauncy Street Boston, MA 02111 TEL. 617.926.3300 www.sasaki.com CIVIL TG MILLER 605 West State Street, Suite A Ithaca, NY 14850 TEL. 607.272.6477 www.tgmillerpc.com STRUCTURAL LEMESSURIER 1380 Soldiers Field Road Boston, MA 02135 TEL. 617.868.1200 www.lemessurier.com MEP/FP RFS ENGINEERING 71 Water Street Laconia, NH 03246 TEL. 603.524.4647 www.rfsengineering.com BUILDING AND FIRE CODE HOWE ENGINEERS 141 Longwater Drive, Suite 110 Norwell, MA 02061 TEL. 781.878.3500 www.howeengineers.com NOT FO R C O N S T R U C TI O N North VEHICLE TRACKING STUDY 28020.00 AR 1" = 20' 3/20/2023 Cornell University JP AG TRUCK BODY TRUCK CHASSIS CROSS HATCHED AREA IS FOR PEDESTRIANS OR LIGHT VEHICLE TRAFFIC ONLY FIRE HYDRANT LOCATIONS ADJACENT TO NE AND SE CORNERS OF BUILDING. - A FREE STANDING BUILDING FIRE DEPARTMENT CONNECTION WILL BE LOCATED ADJACENT TO BOTH HYDRANTS. - A BUILDING SPRINKLER ALARM BELL AND FIRE ALARM STROBE LIGHT WILL BE LOCATED ON BOTH NORTH AND SOUTH SIDES OF THE BUILDING NEAR THE HYDRANTS AND FIRE DEPARTMENT CONNECTIONS. BUILDING NORTH ENTRY: - DESIGNATED AS FIRE DEPARTMENT MAIN ENTRY POINT. - ENTRY VESTIBULE WILL CONTAIN MAIN FIRE ALARM SYSTEM PANEL BUILDING SOUTH ENTRY: - ENTRY VESTIBULE WILL CONTAIN REMOTE FIRE ALARM SYSTEM PANEL www.haleyaldrich.com REPORT ON CORNELL UNIVERSITY INDOOR SPORTS AND RECREATION CENTER & FIELD HOCKEY PITCH CORNELL UNIVERSITY ITHACA, NEW YORK by H & A of New York Engineering and Geology, LLP Rochester, New York for Sasaki Boston, MA File No. 0204866 February 2024 H & A OF NEW YORK ENGINEERINGAND GEOLOGY, LLP 213 W. 35th Street 7th Floor New York, NY 10001 646.277.5685 www.haleyaldrich.com 7 February 2024 File No. 0204866 Sasaki 110 Chauncy Street, Suite 200 Boston, MA 02111 Attention: Robert Titus Subject: Cornell University Indoor Sports and Recreation Center & Field Hockey Pitch Cornell University Ithaca, New York Ladies and Gentlemen: This report presents the results of subsurface explorations completed at the project site by others and by H & A of New York Engineering and Geology, LLP (Haley & Aldrich), and provides geotechnical engineering recommendations and associated construction considerations for the proposed Indoor Sports and Recreation Center, Field Hockey Pitch upgrades, and associated site improvements on the campus of Cornell University in Ithaca, NY, as understood at this time. Our work was conducted in accordance with our signed Sasaki Consultant Agreement dated 16 September 2022. Please contact us with any questions concerning this report. Sincerely yours, H & A OF NEW YORK ENGINEERING AND GEOLOGY, LLP Lysandra L. Reed, P.E. (NY, MA) Project Manager Bradford J. Aldinger, P.E. (CT, MA) Senior Associate Scott Goldkamp, P.E. (MA, NH) Principal \\haleyaldrich.com\share\CF\Projects\0204866\Deliverables\Geotechnical Report\2024-0207-HANY-Cornell ISRC-Geotechnical Report-F.docx Table of Contents Page List of Figures v List of Appendices v 1. Introduction 1 1.1 GENERAL 1 1.2 PURPOSE AND SCOPE 1 1.3 ELEVATION DATUM 2 1.4 EXISTING SITE CONDITIONS 2 1.5 PROPOSED CONSTRUCTION 2 2. Subsurface Exploration Program 3 2.1 TEST BORINGS 3 2.1.1 Historic Borings by Others 3 2.1.2 2023 Test Borings by Haley & Aldrich 3 2.1.3 2024 Infiltration Testing and Sampling by Haley & Aldrich 3 2.2 GEOTECHNICAL LABORATORY TESTING 4 3. Subsurface Conditions 5 3.1 GEOLOGIC CONDITIONS 5 3.2 GROUNDWATER CONDITIONS 5 4. Geotechnical Design Recommendations 7 4.1 GENERAL 7 4.2 SITE DEVELOPMENT 7 4.3 SYNTHETIC TURF FIELD HOCKEY PITCH 7 4.4 INDOOR SPORTS FACILITY FOUNDATIONS 8 4.4.1 Shallow Foundations 8 4.5 SPORT LIGHTING SYSTEM FOUNDATIONS 9 4.6 SETTLEMENT 9 4.7 SLAB-ON-GRADE RECOMMENDATIONS 10 4.8 SEISMIC DESIGN 10 4.9 FOUNDATION DRAINAGE 10 4.10 VAPOR RETARDERS, WATERPROOFING, DAMPPROOFING, AND INSULATION 10 4.11 LATERAL PRESSURES 11 4.11.1 Restrained (At-Rest) Wall Condition 11 4.11.2 Unrestrained (Active) Wall Condition 11 4.12 RESISTANCE TO LATERAL LOADS 11 4.13 SUBSLAB UTILITIES 12 4.14 EXTERIOR GRADING 12 4.15 STORMWATER INFILTRATION SYSTEM 12 Table of Contents Page 4.16 PAVEMENT SECTIONS 12 5. Construction Considerations 13 5.1 GENERAL 13 5.2 EXCAVATION 13 5.3 DEWATERING 13 5.4 PRE-CONSTRUCTION CONDITION SURVEYS 13 5.5 GEOTECHNICAL INSTRUMENTATION 14 5.6 PREPARATION AND PROTECTION OF BEARING SURFACES 14 5.7 BACKFILLING 15 5.8 BACKFILL MATERIALS 16 5.8.1 Granular Fill / Structural Fill 16 5.8.2 Common Fill 16 5.8.3 Base Stone for Turf Field 16 5.8.4 (Free Draining) Finishing Stone 16 5.8.5 Lean Concrete 17 5.9 EARTHWORK DURING FREEZING WEATHER 17 5.10 REUSE OF EXCAVATED MATERIALS 17 5.11 CONSTRUCTION OBSERVATION 17 5.12 REVIEW OF CONTRACT DOCUMENTS 18 6. Limitations 19 v List of Figures Figure No. Title 1 Project Locus 2 Site and Subsurface Exploration Location Plan List of Appendices Appendix Title A Logs of Previous Explorations B Haley & Aldrich Test Boring Logs and Observation Well Installation Report C Infiltration Test Results and Boring Logs D Laboratory Test Results E Memo of Understanding Between CLASSE and the F&CS Project Managers for the New Indoor Recreation & Sports Center 1 1. Introduction 1.1 GENERAL This report provides subsurface information and our geotechnical engineering recommendations and associated construction considerations for the Cornell Indoor Sports and Recreation Center (ISRC) & Field Hockey pitch on the Cornell University campus in Ithaca, New York. The project location is generally shown on the Project Locus, Figure 1. We have coordinated our work with the following project team members:  Owner: Cornell University (Cornell);  Architect: Sasaki;  Structural Engineer: LeMessurier; and  Civil Engineer: T.G. Miller, P.C. In addition to this report, we completed a Schematic Design Geotechnical Narrative dated 13 September 2022. This report supersedes our prior issued study and report. Our current understanding of the existing conditions and proposed construction is based on discussions with the project team identified above, and our review of the following available project documents and drawings:  January 2022 RFP Package titled “Indoor Sports and Recreation Center Design Services.”  Drawings Titled “Design Development Set,” dated 22 December 2023, prepared by Sasaki.  Report titled “Preliminary Geotechnical Evaluation: Proposed Covered Athletic Facility,” dated 27 March 2019, prepared by Stantec.  Technical Report titled “Project Definition Design Study for the Energy Recovery LINAC upgrade to the Cornell Electron Storage Ring,” dated 30 September 2008, prepared by Ove Arup & Partners Consulting Engineers PC.  Report titled “Subsurface Investigation: Athletics Field House,” dated 30 May 1986, prepared by Empire Soils Investigations, Inc.  Report titled “Foundation Engineering Report: Biotechnology Research Facility,” dated 14 March 1986, prepared by McPhail Associates, Inc.  Report titled “Report of Subsurface Investigation and Geotechnical Evaluation: Life Science Technology Building,” dated 14 August 2003, prepared by Atlantic Testing Laboratories, Limited.  Report titled “Geotechnical Engineering Evaluation: Lynah Ice Rink Additions,” dated April 2005, prepared by Hawk Engineering, PC. 1.2 PURPOSE AND SCOPE This subsurface investigation program was undertaken to obtain information on subsurface conditions in support of the development of geotechnical recommendations for the design and construction of the Cornell ISRC and Field Hockey pitch upgrades project. Our scope of services included: 2  reviewing readily available information on site history, subsurface soil and bedrock conditions, and groundwater levels;  planning and implementing a geotechnical test boring program;  logging test borings, obtaining samples, and measuring groundwater levels;  performing geotechnical analyses; and  preparing this geotechnical engineering report. 1.3 ELEVATION DATUM Elevations herein are in feet and refer to the National Geodetic Vertical Datum of 1929 (NGVD29). 1.4 EXISTING SITE CONDITIONS The existing site is currently occupied by the turf Field Hockey pitch and adjacent grass playing fields which is collectively known as Robinson Alumni Fields. A majority of the proposed site is located within the City of Ithaca (west two-thirds of the Site) and the east portion is located within the Town of Ithaca. Existing ground surface elevation ranges from about El. 871 on the west side of the site and grades up to El. 878 on the east end of the site. The site is bordered by a parking lot and Bartels Hall to the south, a track and sports field to the east, a parking lot and Tower Road to the north and Weill Hall to the west. A portion of the proposed construction is located directly above the Cornell Synchrotron Tunnel alignment. The Tunnel was mined in 1965 using steel ring sections with precast concrete segments and shotcrete lining. The crown of the tunnel is at approximate El. 837, about 40 feet (ft) below existing ground surface. Along the western perimeter of the site, the below-grade portion of Weill Hall extends within the limits of the site. The footings for this portion of Weill Hall bear at El. 851.5. Additionally, the Weill Hall stormwater management system is located below the southwest corner of the proposed synthetic turf Field Hockey pitch. Numerous utilities (steam, electric, telecommunications, water, sewer, field irrigation) traverse below the site, generally along the southern perimeter of the site and through a utility corridor located approximately in the mid-portion of the site. An irrigation system is located below both natural grass fields. 1.5 PROPOSED CONSTRUCTION We understand the proposed project consists of relocation of the existing Field Hockey pitch and construction of a new indoor recreation and intercollegiate and club practice and competition space. The new facility will have a footprint of approximately 94,000 square feet and will be about 54 ft in height. The new turf Field Hockey pitch will consist of a synthetic turf field with a new scoreboard and four-pole sport lighting system. Stormwater is planned to be managed onsite at both a bioretention area at the northern perimeter of the site and a stormwater retention system located below the southeast section of the proposed Field Hockey field. 3 2. Subsurface Exploration Program 2.1 TEST BORINGS 2.1.1 Historic Borings by Others Information on previous explorations conducted in the vicinity of the project site was provided by Cornell for the following projects:  Bartels Hall: Test borings drilled by Empire Soils Investigations, Inc. in May 1986 for the multipurpose field house east of Lynah Rink and south of the proposed site.  Weill Life Science Technology Building: Test borings drilled by Atlantic Testing Laboratories, Limited in June and July 2003 for the Weill Life Science building to the west of the proposed site.  Biotechnology Research Facility: Test borings drilled by Empire Soils Investigations, Inc. in November 1972 for the biotechnology research facility west of the Weill Life Science building.  Lynah Ice Rink Addition: Test borings drilled by Hawk Engineering, P.C. in March 2005 for the additions on the north and south sides of the Lynah Ice Rink. Logs and location plans for the historical test borings are provided in Appendix A. 2.1.2 2023 Test Borings by Haley & Aldrich Haley & Aldrich planned and monitored a subsurface exploration program consisting of ten test borings, designated HA-1 to HA-10, to obtain subsurface information to support geotechnical aspects of project design, including depth to suitable bearing materials. The borings were drilled by Nothnagle Drilling, Inc. of Scottsville, New York (Nothnagle), between 11 and 13 December 2023. Borings were advanced with a track-mounted CME 55 MCX drill rig using 4-in I.D. hollow-stem augers to depths of 12 to 20 ft below ground surface (bgs). Standard Penetration Tests (“SPTs”) were performed continuously in the top 10 ft, and at 5 ft intervals thereafter. One groundwater observation well, HA-2 (OW), was screened in natural soils in a completed borehole. The other boreholes were backfilled with soil cuttings upon completion. The locations of the recent borings were identified in the field using a handheld GPS unit. Ground surface elevations at the recent borings (including the observation well) were estimated using the elevation contours shown on the existing conditions plan prepared by others. Therefore, location and elevations for the recent explorations should be considered approximate and accurate only to the degree implied by the method used. Locations of the recent borings and observation well are shown on Figure 2. Logs of recent borings and the observation well installation report are provided in Appendix B. 2.1.3 2024 Infiltration Testing and Sampling by Haley & Aldrich Haley & Aldrich monitored a portion of a recent subsurface exploration program developed by the project civil engineer, T.G. Miller, P.C. (T.G. Miller), to support the design of a stormwater management system, also by T.G. Miller. The infiltration test locations were determined by T.G. Miller and were 4 identified in the field using a handheld GPS unit and verified using measurements from known site features. Locations of the infiltration tests are shown on Figure 2. Logs of the infiltration test borings and results of the testing are provided in Appendix C. The program consisted of five in-situ permeability tests, designated B-1 through B-5, and the collection of soil samples from two test borings, designated B-2A and B-5A, for soil classification and testing. The geotechnical testing of soil samples was performed in accordance with the New York State Department of Environmental Conservation Stormwater Design Manual Appendix D. The borings and test locations were drilled by Nothnagle on 22 to 23 January 2024. Borings were advanced with a Geoprobe 6712 DT drill rig using 4-in I.D. hollow-stem augers to depths of 7 to 9 ft bgs. SPTs were performed in the two test borings from depths of 5 to 9 ft. The infiltration testing was performed in accordance with Appendix D of the New York State Stormwater Design Manual. Upon drilling to design depth, a 4-in. diameter PVC pipe was temporarily installed to the bottom of the test boring exploration, 2 ft below the bottom of the proposed practice. The test holes were presoaked 24 hours before the falling head infiltration testing was performed. The test results for the five tested locations are included in Appendix C and are summarized below. Exploration Designation Estimated Hydraulic Conductivity (cm/sec) B1 8.5 x 10-5 B2 4.6 x 10-4 B3 ND B4 6.9 x 10-5 B5 ND Note: ND indicates Not Determined Upon completion of the infiltration testing, the PVC casing was removed, and all boreholes were backfilled to ground surface with soil cuttings. 2.2 GEOTECHNICAL LABORATORY TESTING Select soil samples collected as part of the infiltration testing program were submitted to a geotechnical laboratory for grain size testing to aid with soil classification and to evaluate infiltration rate relative to permeability testing conducted in the field. Results of the laboratory testing are provided in Appendix D. 5 3. Subsurface Conditions 3.1 GEOLOGIC CONDITIONS The results of the recently completed test borings generally indicate the following sequence of subsurface units in order of occurrence from ground surface downward. Generalized Strata Description Range in Thickness (ft) Depth Below Ground Surface to Top of Stratum (ft) Ground Cover (Topsoil) 0.5 to 2 - Fill/Reworked Natural Material 0 to 5.5 0.5 to 2 Glaciolacustrine Silt and Sand 6.2 to 6.6, where identified 0.5 to 6 Glacial Till Not determined 13.4 to 13.8, where encountered Generalized soil strata encountered in the recent test borings are described below in order of increasing depth. Detailed descriptions of each stratum and the Unified Soil Classification System (“USCS”) Group Symbol for each sample are provided on the logs in Appendix B. The stratification lines designating the interface between strata on the logs are approximate. The logs depict subsurface conditions at the specific exploration location and at the time designated on the logs.  TOPSOIL – A relatively thin layer of loose topsoil was encountered at ground surface at all boring locations.  FILL and Reworked Natural Material – Encountered below the topsoil in 6 of the 10 borings, this layer was generally described as soft to stiff, sandy silt and silty sand with varying amounts of gravel and traces of clay tile or brick fragments.  SILT and SAND, Glaciolacustrine Deposits – Encountered below the topsoil or fill, the natural Glaciolacustrine Deposits were described as soft to hard, gray-brown to red-brown silt and sand with varying amounts of gravel and clay. There was generally increasing sand content and increasing gray color with depth, and mottling and signs of oxidation were observed. Most of the borings were terminated in this stratum.  GLACIAL TILL – Typically described as very loose to dense, brown to gray-brown, silty sand and silty gravel with sand and trace rock fragments. The Glacial Till was encountered at the center of the site in borings HA-5 and HA-10. This stratum was generally more dense and well- graded/non-uniform than the Glaciolacustrine Deposits. Where test borings were not terminated within the Glaciolacustrine Deposits, the test borings were terminated within the Glacial Till Deposit. 3.2 GROUNDWATER CONDITIONS During drilling, groundwater was encountered in borings HA-2 and HA-6 at depths of 14 to 10.4 ft bgs, between approximate El. 860 to 864.6. At the other eight test boring locations, groundwater was not encountered to the bottom of the test boring (approximately 12 to 20 ft bgs). A groundwater observation well was installed in boring HA-2 and was set in the natural soils within the Glaciolacustrine Deposit. One day after well installation, groundwater was measured at a depth of 10.3 ft bgs, at approximate El. 863.7. Approximately one month after installation, groundwater was 6 measured at a depth of 11.6 ft bgs, at approximate El. 862.4. The groundwater in this area is likely locally perched above the hard Glaciolacustrine Deposits identified in this boring and is the result of the relatively impermeable soil conditions at this location. Locally perched groundwater levels may be encountered at other locations across the site associated with trapped stormwater. Water levels can be expected to vary with seasonal changes, precipitation, snow melt, construction activities, and other factors, and should be anticipated to vary both during and following construction. The local geology and topography also likely will impact groundwater levels on the site. Groundwater may be perched on top of low permeability soils, such as the Glaciolacustrine soils and Glacial Till. As a result, water levels encountered during and following construction may differ from those encountered in the explorations. 7 4. Geotechnical Design Recommendations 4.1 GENERAL This section provides recommendations for design of foundations and slabs for the proposed re- development at the site. Foundations should be designed and constructed in accordance with the current edition of the New York State Building Code (Code), and the recommendations provided in the following sections. 4.2 SITE DEVELOPMENT Within the limits of the proposed area for new structure, synthetic turf field, and site features, construction will require excavation of Topsoil and Fill soils in order to reach the suitable bearing subgrade prior to construction. In some locations, and depending on final design elevation for structures, localized deeper excavations within the Fill may be required to reach suitable bearing elevations. Existing utilities to be abandoned within the limits of the site will require cut-and-capping beyond the plan limits of proposed structures and complete removal within the footprint of the site. Existing, active utilities to remain and new utilities to be installed will require coordination with new foundation work to avoid potential design conflicts, and construction activities will need to be coordinated to not impact the operation of active, existing utilities or the construction of new utilities. Construction will require management of existing on-site materials during excavation of Topsoil and Fill across the site. To minimize the cost of transporting and disposing off-site, effort should be made by the designers and contractors to process and re-use excavated material on-site. 4.3 SYNTHETIC TURF FIELD HOCKEY PITCH We understand that the new Field Hockey pitch is planned to be constructed such that the playing surface will be generally at the same grade as the current natural grass field. As such, preparation of the subgrade immediately below the synthetic turf system will require some excavation/stripping and removal of the topsoil within the limits of the field.  In some areas where the anticipated topsoil thickness extends below the design subgrade elevation, we recommend that the excavation extend as needed to completely remove the topsoil materials, followed by controlled placement and compaction of an approved backfill material up to design subgrade elevation. Backfill materials may include previously excavated soils or may require importing Granular Fill.  Re-use of excavated soils will be dependent upon visual characterization of the materials and results of grain size analyses and laboratory compaction tests. Accordingly, we recommend to the extent possible, that an on-site location be established for segregating and stockpiling excavated soils.  Following completion of excavation to strip/remove the near surface soils down to subgrade elevation for the turf system, static roll the surface using a large compaction roller to prepare a 8 firm, dry and stable subgrade. If, during static rolling of the subgrades, pumping or weaving conditions are observed, alternate compaction techniques may be required and/or additional subgrade preparation may be recommended (e.g., removal and replacement of soft, compressible soils).  At all times prior to placement of the turf system, we recommend maintaining a dry and undisturbed design subgrade so as to promote a stable working surface to receive the turf system. Temporary re-grading outside the limits of the new field may be considered so as to divert surface water runoff away from the work areas. Construction dewatering is not anticipated to be required; however, if it becomes necessary, the Contractor shall make efforts to discharge dewatering effluent on-site at distances away from the work areas so as not to disturb subgrade preparation and to allow for construction in-the-dry.  The turf system subgrade soils are anticipated to consist of silty sand and sandy silt materials. In the event the work is conducted during winter conditions, be advised that these types of soils could be susceptible to disturbance due to freezing and thawing temperatures and the Contractor should sequence operations, including protection of exposed and excavated (i.e., stockpiled) soils from moisture, to allow for successful completion of the work.  For the permanent condition, the maintenance, protection, and long-term performance of the synthetic turf field will require an effective stormwater runoff collection and management system. At a minimum, the sub-turf drainage systems must be designed such that the system is entirely and at all times above groundwater level. Pending further discussions with Sasaki regarding final surface grading and estimated runoff volume calculations, we recommend a sub- turf drainage system design comprised of a layer of double-washed, AASHTO No. 57 crushed stone (Sasaki to determine minimum thickness required) with perforated HDPE pipes (sized by Sasaki) embedded within the crushed stone so as to effectively collect and transport by gravity any accumulated runoff water that filters from the turf layer above to an appropriately sized on- site collection/groundwater recharge/infiltration system (or direct discharge into a permitted storm drain). Prior to placing the crushed stone and perforated piping, and to facilitate vertical drainage of stormwater, a nonwoven geotextile fabric (Mirafi 160N or similar) should be placed on top of the prepared and approved subgrade. 4.4 INDOOR SPORTS FACILITY FOUNDATIONS Subsurface conditions at the site are generally favorable for supporting new building loads on conventional spread footing foundations founded directly on naturally deposited soils. The fill soils and soft, loose, or otherwise unstable Glaciolacustrine silts and sands are not considered suitable bearing soils. 4.4.1 Shallow Foundations Recommendations for design of new footing foundations are provided below.  Footings should be designed using a maximum allowable bearing pressure of the following: – 4.0 kips per square foot (ksf) bearing in naturally deposited Glaciolacustrine silts and sands; and 9 – Allowable bearing pressures indicated above assume over-excavation and replacement of Fill and loose or soft materials at bearing level followed by replacement with compacted structural fill.  The minimum footing width should be 3 ft.  In general, footing bottoms bearing in soil should be positioned a minimum of 4 ft below adjacent ground surface exposed to freezing temperatures. Footings bearing at locations not exposed to freezing temperatures may bear as shallow as 18 in. below the floor slab provided the tops of footings are at least 6 in. below the bottom of the adjacent floor slab.  Soil bearing footings should be designed to bear below a reference line drawn upward and outward on a 1.5 horizontal to 1 vertical (1.5H:1V) slope from the bottom of adjacent utilities or other underground structures, or future planned excavations. Where possible, footing elevations should be coordinated with utility elevations to allow utilities to pass through the foundation wall (rather than through or beneath the footing). Footing bearing elevations may locally need to be lowered or stepped to achieve this criterion. 4.5 SPORT LIGHTING SYSTEM FOUNDATIONS Due to the thickness of Fill and variable and inconsistent density in the upper soils, as observed in the recent test boring program and the historic test borings conducted for Weill Hall, we recommend the sport lighting systems be supported on Caissons (Drilled Shafts). Typically, the lighting system includes a pre-cast concrete “base” encased in a concrete filled caisson and designed to bear on natural inorganic soils. The diameter and design depth of the foundation element into the Glaciolacustrine Deposits will depend on the anticipated combined foundation loadings (vertical, lateral and moment loads) calculated by the designer of the foundations based on the criteria in the below table. Light Pole Foundation Design Criteria Glaciolacustrine Deposit Total Unit Weight (lb/ft3) 125 Buoyant Unit Weight (lb/ft3) 62.6 Effective Friction Angle (deg) 32 Undrained Shear Strength (psf) N/A Active Earth Pressure Coefficient (Ka) 0.3 Passive Earth Pressure Coefficient (Kp) 2.1 (2) Notes: 1. Fill and organic soils are not suitable for foundation support and should not be counted on for foundation support. 2. Passive Earth Pressure Coefficient (Kp) includes a factor of safety of 1.5. Footing foundations for the bleacher system or team area structures should be designed based on an allowable bearing pressure of 4.0 ksf in the Glaciolacustrine Deposit. The footing should bear at least 4 ft below the lowest ground surface exposed to freezing. 4.6 SETTLEMENT For the recommended allowable bearing pressures and bearing conditions, we estimate total settlement of foundation elements will not exceed about 1 in. with differential settlements between adjacent columns or along 30 ft length of strip footings not exceeding about ½ in. The majority of the settlements 10 will typically occur as structure dead load is applied during construction, and during application of live loads and roof snow loading. 4.7 SLAB-ON-GRADE RECOMMENDATIONS We recommend designing the concrete floor slabs as soil-supported slabs-on-grade bearing on a base course consisting of structural fill. The base course thickness should be 12 in. minimum. Soils to remain in-place should be observed by the Geotechnical Engineer to confirm they are firm and stable during proof-compaction and prior to placement and compaction of backfill to subgrade elevation. The synthetic turf system should be supported on a layer of crushed stone directly over a properly prepared subgrade. Soils to remain in-place beneath the crushed stone layer should be observed by the Geotechnical Engineer to confirm they are firm and stable during proof-compaction. A nonwoven geotextile (Mirafi 160N or equivalent) should be placed between the crushed stone layer and underlying soil. 4.8 SEISMIC DESIGN  Based on observed groundwater levels and soil conditions, site soils are not considered susceptible to liquefaction during the Code-mandated design earthquake.  Seismically-induced total and differential settlements are anticipated to be less than 1 in.  Seismic Site Class D should be used in design, based on the subsurface profile and available data.  Per the Code and the conditions encountered in the test borings, the applicable seismic design criteria are as follows: SS = 0.15; S1 = 0.06; Fa=1.6; and FV=2.4. 4.9 FOUNDATION DRAINAGE Perimeter drainage is recommended around the entire building perimeter. The perimeter drainage system should consist of a continuous 4 in. diameter Schedule 40 perforated PVC (or corrugated polyethylene) pipe laid flat or with a slight pitch (about 2%) with slots down, at the exterior base of the lowest level walls. The pipe should be completely surrounded with a minimum of 6 in. of ¾-in. washed Crushed Stone, surrounded by a nonwoven geotextile. This drain around the perimeter of the building should be designed to flow by gravity to the site storm drain system. 4.10 VAPOR RETARDERS, WATERPROOFING, DAMPPROOFING, AND INSULATION Buried exterior foundation walls, pits, and depressions extending below a depth of 10 ft below exterior ground surface are recommended to be waterproofed. We recommend that waterstops, caulking, or other seals be provided at all foundation wall and exterior wall/footing construction joints. Foundation walls and slabs less than 10 ft bgs should be insulated and damp-proofed in accordance with Building Code requirements, as applicable. We recommend providing a moisture vapor retarder membrane directly beneath the ground floor slabs in occupied and finished spaces, in accordance with ACE 302.2R-06, especially if humidity control is desired or relatively vapor-tight coverings will be used on the floors. 11 4.11 LATERAL PRESSURES Building foundation walls serving as retaining walls should be designed in accordance with the applicable below-listed lateral pressures. The height of the wall (H) is defined as the distance in feet between finished grade and the top of the lowest level floor slab. For seismic loading conditions, walls should be designed to resist static earth plus seismic pressures. Surcharge pressures do not need to be considered for seismic design unless the surcharge will be applied over an extended time period. The recommended minimum factors of safety against sliding and overturning under static loading conditions is 1.5. The recommended minimum factors of safety against sliding and overturning under seismic loading conditions is 1.2. Passive soil pressure should not be included as a resisting force. 4.11.1 Restrained (At-Rest) Wall Condition Design walls that are braced at the top and bottom for the following lateral pressures:  Static Earth: Equivalent fluid unit weight equal to 65 pounds per square foot (psf) per foot depth.  Seismic: Inverted triangular pressure applied over the height of the wall (H) (where H is in feet) with a magnitude of 4.7 H psf at the top of the wall.  Surcharge: Uniform pressure applied from the elevation of the surcharge to the top of footing with a magnitude of 0.5q psf, where q is the vertical surcharge pressure psf. 4.11.2 Unrestrained (Active) Wall Condition Design walls that are free to deflect at least 0.00125H (where H is the height of the wall in feet) at the top of the wall (i.e., are not braced) for the following lateral pressures:  Static Earth: Equivalent fluid unit weight equal to 45 psf per foot depth.  Seismic: Same as for restrained walls.  Surcharge: Same as for restrained walls except with a magnitude of 0.3q. 4.12 RESISTANCE TO LATERAL LOADS Lateral loads acting on the structure can be resisted by passive earth pressures acting against below grade portions of the structure such as footings or grade beams and frictional resistance between the bottom of concrete foundations and the underlying soil. Passive forces to resist lateral loads may be calculated based on an equivalent fluid unit weight of soil equal to 250 pounds per cubic foot (pcf). This value assumes that granular backfill is placed and systematically compacted in lifts. If the backfill is not systematically compacted, an equivalent fluid weight of 100 pcf should be used. A coefficient of friction between cast-in-place concrete and the Glaciolacustrine Deposits bearing strata equal to 0.3 should be used to calculate ultimate sliding resistance. A factor of safety of at least 1.5 should be applied to calculate the allowable sliding resistance. 12 4.13 SUBSLAB UTILITIES Utilities beneath slabs may be soil-supported (with suitable bedding) bearing on existing inorganic fill soils or natural material that is stable under proof-compaction, or on compacted structural fill placed following the removal of exposed unsuitable bearing materials, as applicable. Utilities should be located above foundation bearing levels or above an imaginary reference line drawn downward and away from the lower edge of the soil-supported foundation element at a 1.5H:1V slope. Utilities that may be sensitive to inundation should be constructed watertight. 4.14 EXTERIOR GRADING Surface runoff should be directed away from the building by sloping grades downward and away from the building, use of swales or drainage trenches, and providing a low permeability surface finish adjacent to building walls. Low permeability surface finishes may include bituminous pavements, concrete sidewalks, or a 6-in. minimum thickness of low permeability backfill such as topsoil. 4.15 STORMWATER INFILTRATION SYSTEM The Fill soils were noted to be variable in nature and visual observation indicated that the fines content of the Fill ranges considerably from 10 to 50%. Additionally, the Fill is underlain by lower permeability Glaciolacustrine Deposits. Given the variable nature of the Fill and the presence of Glaciolacustrine Deposits that could act as an aquitard, stormwater infiltration could be difficult to achieve. Based on in-situ testing, the hydraulic conductivity of the Glaciolacustrine Deposits ranges from roughly 4.2x10-5 to 3.7x10-4 cm/sec, which equates to an infiltration rate (Rawls Rate) of roughly 0.06 to 0.52 in./hr. (Textural Class of Silty Clay Loam to Loam, respectively). The design of the proposed stormwater infiltration practice will need to consider these rates and low permeability soils encountered at the site. 4.16 PAVEMENT SECTIONS The existing Fill is frost susceptible. There is some risk that paved areas could experience small amounts of frost heaving and vertical misalignment where they are directly underlain by these soils within the regional depth of frost penetration (4 ft). To limit risk of any frost-induced heaving and the associated premium costs for short-term pavement maintenance, a full depth (4 ft frost depth potential) non-frost susceptible pavement section would be required; however, this is not common construction practice in this locale and is typically determined to be cost prohibitive. A 12-in. thick structural base course, consisting of compacted Granular Fill, should be used for all pavements and pavers. The base course should be placed and compacted to 95 percent of the maximum dry density as determined by ASTM D1557. Compacted Granular Fill beneath structures, pavement sections, and to raise site grades should consist of suitable bank-run sand and gravel, free of clay, organic material, snow, ice, or other unsuitable materials and should be well graded. 13 5. Construction Considerations 5.1 GENERAL This section provides comments related to foundation construction, excavation, dewatering, subgrade preparation, earthwork, and related geotechnical engineering aspects of the project. It will aid those responsible for the preparation of contract plans and specifications, those involved with construction monitoring, and those doing the work. Contractors must evaluate potential construction problems on the basis of their own knowledge and experience in the area, on campus, and on the basis of similar localities, taking into account their own proposed construction methods, procedures, and available equipment. In addition to the construction guidelines and recommendations made herein, excavation and construction activities should conform to the requirements of OSHA and other applicable regulatory agencies. 5.2 EXCAVATION Considering the proposed structure does not have a basement or below grade space, local shallow excavations will be required for footings and pits. Where space permits, open cut soil slopes inclined no steeper than 1.5H:1V are considered feasible provided existing and/or new structures are not undermined. However, such slopes should be confirmed on a case-by-case basis at the time of excavation. Some sloughing and raveling should be anticipated on temporary earth slopes constructed at this inclination. Excavation and sloping should be conducted in accordance with OSHA and other applicable regulations. All final excavation work and excavations within existing spaces should be conducted in-the-dry. The silty, clayey site soils are highly susceptible to water disturbance. Control of surface and seepage water into excavations for footings and other areas will be necessary to avoid disturbance of bearing surfaces and promote completion of below-grade work within existing spaces. The Contractor should control the flow of surface water, precipitation, and seepage water into excavations at all times. Construction dewatering will be necessary as discussed below. 5.3 DEWATERING Final excavations, subgrade preparation, filling, foundation construction, and utility construction should be conducted "in the dry". Excavations to construct foundations and new utilities are anticipated to be above the stable groundwater level. However, given that site soils are typically poor draining, we anticipate that excavations will encounter pockets of perched groundwater above the glacial till and bedrock, as well as surface water runoff, precipitation, and utility trench fill seeps requiring dewatering. 5.4 PRE-CONSTRUCTION CONDITION SURVEYS We recommend that pre-construction condition surveys be conducted in Bartels Hall and at existing structures to remain adjacent to the site prior to commencement of construction or demolition of existing site improvements. If desired, pre-construction surveys of other buildings within about 100 to 200 ft can be conducted by the Contractor or Cornell. 14 5.5 GEOTECHNICAL INSTRUMENTATION The proposed construction will be in close proximity to the existing below-grade synchrotron ring and a light tower that is the site of a red-tailed hawk nest. As Cornell would like to protect their assets by employing construction techniques that mitigate potential movements of existing structures, we recommend collection of data to evaluate potential movements of existing structures during construction. Specifically, we recommend installation of select geotechnical instrumentation to measure movements and facilitate subsequent implementation of mitigation measures should the measured movements of existing structures reach threshold or limiting levels (to be specified in the contract documents). An instrumentation and monitoring program should be established in accordance with the “Memo of Understanding between CLASSE and the F&CS Project Managers for the New Indoor Recreation and Sports Center” document, attached as Appendix E. The instrumentation program may include one or more of the following:  Preconstruction condition surveys (video/photo documentation) at the exterior of buildings adjacent to the site as well as the streets and sidewalks (if remaining) adjacent to the site.  Vibration monitoring (with engineering seismographs) at the site perimeter if desired. We note that relatively low vibration methodologies for foundations were recommended herein.  Survey reference points to measure vertical movements adjacent buildings, streets, utilities, and other structures. Details of the program (instrumentation types, measurement frequency and duration, etc.) can be determined through project team discussions. 5.6 PREPARATION AND PROTECTION OF BEARING SURFACES Exposed subgrade soils should be observed in the field by a Geotechnical Engineer to confirm the assumed foundation bearing conditions. It may be necessary to require over-excavation and replacement of loose, disturbed, or otherwise unacceptable foundation bearing soils. Following excavation to the foundation bearing level, granular soil subgrades should be re-compacted with a minimum of four passes of appropriate construction equipment, as indicated below, noting however that re-compaction should be terminated if the subgrades exhibit signs of pumping or disturbance. Fine-grained bearing level soils should be excavated with a smooth edge bucket and not recompacted. Subgrade materials disturbed because of excavation, excessive or inappropriate compaction, and/or insufficient dewatering operations (as judged by the Geotechnical Engineer) should be removed and replaced with compacted structural fill (or suitable alternate). If soft, unstable, or unsuitable material is encountered at the subgrade, the unsuitable material should be over-excavated and backfilled with compacted structural fill (or suitable alternate), and the subgrade compacted until firm and stable. Given the sensitivity to disturbance due to moisture and traffic, soil subgrade preparation for footings may include placement of a 3 in. minimum thickness of Lean Concrete immediately following excavation. Excavations should be then backfilled as soon as practical. 15 Care should be taken to prevent surface water from collecting on exposed soil subgrades. Worker and equipment traffic on bearing surfaces and subgrades should be minimized. If subgrade protection difficulties are encountered due to water or inclement weather, various approaches can be utilized:  Leave subgrades high until immediately before forming and concreting to minimize the time the subgrade is exposed.  Over excavate footings by 6 in. using a smooth edged bucket, and backfill to the design bearing elevation with a lean concrete mud mat. Soil bearing surfaces below completed foundations must be protected against freezing before and after foundation construction. If construction occurs during freezing weather, footings should be sufficiently backfilled as soon as possible after they are constructed. Alternatively, insulating blankets, heating, or other means may be used for protection against freezing. 5.7 BACKFILLING Backfilling of footings, slabs, foundation walls, and underslab utilities will be necessary. Lean concrete mud mats are recommended to be placed beneath footing subgrades as described herein. Compacted structural fill and suitable Common Fill (as judged by the Geotechnical Engineer) may be used for backfilling. Compacted structural fill should be used for filling within the building area, except where lean concrete is required, unless otherwise accepted by the Geotechnical Engineer. Compacted soil fills should be placed in lift thicknesses not exceeding 10 in. in loose measure. Compaction equipment should consist of walk-behind vibratory rollers imparting a dynamic force of at least 5,000 lbs. In confined areas, hand-guided equipment such as a large vibratory plate compactor should be used, and the loose lift thickness should not exceed 8 in. A minimum of four to six systematic passes of the compaction equipment should be used to compact each lift. Cobbles or boulders having a size exceeding 2/3 of the loose lift thickness should be removed prior to compaction. Recommended compaction requirements are as follows (and make reference to percentages of the maximum dry density determined in accordance with ASTM D1557): Location Minimum Compaction Requirements Beneath and around footings, 95% and beneath slabs-on-grade Parking, roadways 92% deeper than 3 ft below finished grade and sidewalks 95% within 3 ft below finished grade Level landscaped areas Per Landscape Architect Requirements 16 5.8 BACKFILL MATERIALS 5.8.1 Granular Fill / Structural Fill Granular Fill should consist of uncontaminated, natural, bank-run sand and gravel, free of organic material, snow, ice, debris, or other unsuitable materials and should be well-graded within the following limits: U.S. Standard Sieve Size Percent Finer by Weight 3 in. 100 No. 4 30-80 No. 40 10-50 No. 200 0-8 5.8.2 Common Fill Common Fill (Ordinary Fill) shall consist of mineral soil free from organic materials, loam, wood, ice, cinders, asphalt, concrete, trash and other objectionable materials. Common Fill shall not contain stones larger than 6 inches in largest diameter and shall have a maximum of 80 percent passing the No. 40 sieve and a maximum of 30 percent passing the No. 200 sieve. It should not contain broken concrete, masonry rubble or other similar materials and shall have physical properties such that it can be readily spread and compacted during filling. Snow, ice and frozen soil shall not be permitted. 5.8.3 Base Stone for Turf Field The base stone below the synthetic turf field should meet the gradation requirements of AASHTO No. 57 stone. Crushed stone shall consist of natural, angular, crusher run material, and shall be double-washed at the source site prior to import to remove fine grained soils prior to use on the project. Sieve Size Percent Finer by Weight 1 ½ in. 100 1 in. 95-100 ½ in. 25-60 No. 4 0-10 No. 8 0 - 5 5.8.4 (Free Draining) Finishing Stone Free Draining Finishing Stone shall be utilized to fill minor depressions in the existing base as part of the regrading process. This material shall be inert, angular crushed rock derived from a stone quarry that is hard, durable, and free of deleterious materials and shall not consist of natural or crushed sand. Materials that break up when alternately frozen and thawed or wetted and dried shall not be used. The Free Draining Finishing Stone layer shall be uniformly blended according to the gradation requirements for the respective stone sizes for the following (1/2-in. maximum particle size): 17 U.S. Standard Sieve Size Percent Finer by Weight 1/2 in. 100 3/8 in. 85-100 No. 4 60-90 No. 8 35-75 No. 16 10-55 No. 30 0-40 No. 60 0-15 No. 100 0-8 No. 200 0-2 The material shall also meet the Los Angeles Abrasion Test AASHTO T96 of not more than 45% loss and the Sodium Sulfate Soundness AASHTO T104 of not more than 12%. 5.8.5 Lean Concrete Lean Concrete should have a minimum design compressive strength (f’c) of 2,000 psi. 5.9 EARTHWORK DURING FREEZING WEATHER Precautions should be taken if work occurs while temperatures are below freezing. Frozen soil or soil containing snow or ice should not be used as compacted fill. Placement of compacted fills should not be conducted when air temperatures are low enough (approximately 30 degrees F., or below) to cause freezing of the moisture in the fill during or before placement. Similarly, lean concrete and concrete placed during freezing temperatures should be protected using insulating blankets, tenting and heating, or other means until the concrete has achieved the design compressive strength. Backfill materials should not be placed on water, snow, ice, or frozen soil. Backfill should not be allowed to freeze prior to compaction. At the end of each day's operations, the last lift of backfill, after compaction, should be rolled by a smooth-wheeled roller to eliminate ridges of uncompacted soil. Silty and clayey soils are susceptible to disturbance by freezing, especially in the presence of water and traffic. 5.10 REUSE OF EXCAVATED MATERIALS Given the proposed construction and nature of the on-site soils to be excavated, large scale on-site re- use of excavated materials is not anticipated to be logistically or economically advantageous. On-site reuse of the more granular soils, to the extent possible, is encouraged. Due to high fines content of site soils, excavated material will not be suitable for reuse as select backfill but may be suitable for reuse as Common Fill for raise in grade in landscaped areas if it can be successfully placed and compacted. If soils cannot be reused on site or elsewhere on the campus (e.g., can the silty, clayey soils be used elsewhere in landscaping areas or in a stockpile), an allowance for off-site disposition should be carried in the project budget. 5.11 CONSTRUCTION OBSERVATION The recommendations contained in this report are based on known and reasonably-predictable behavior of properly engineered and constructed foundations and other facilities. 18 We recommend that an engineer or technician, qualified by training and experience, perform field observations of the geotechnical aspects of construction summarized below. Given our familiarity with the recommendations herein and the site conditions, we strongly recommend that an engineer or technician from Haley & Aldrich observe the work indicated below to mitigate the potential for contractor claims, facilitate expedient resolution of geotechnical items that arise during construction, and to mitigate the overall project costs. Activities requiring Special Inspection by a New York State Professional Engineer per the Building Code are:  excavation and removal of unsuitable foundation and slab bearing materials;  preparation of foundation and slab bearing surfaces; Other activities that may be completed by a qualified Testing Agency:  vibration monitoring (if required);  confirm that backfill materials conform to project plans and specifications; and  placement and compaction of Structural Fill (including field compaction control testing). 5.12 REVIEW OF CONTRACT DOCUMENTS We recommend that Haley & Aldrich be provided the opportunity for a review of the drawings and specifications to confirm that the recommendations in this report were interpreted and implemented as intended. 19 6. Limitations This report has been prepared for specific application to the Cornell Indoor Sports and Recreation Center project on the Ithaca, New York campus of Cornell University, and is intended for the exclusive use of the project team in connection with the geotechnical aspects of this project only. In the event that changes in the nature, design, or location of the project occur, the conclusions and recommendations contained in this report should not be considered valid unless they are reviewed and modified or verified in writing by Haley & Aldrich. The conclusions and recommendations are based in part upon data obtained from the referenced explorations and sampling on the dates indicated herein. The nature and extent of potential variations between the explorations and samples may not become evident until construction. If variations are observed during additional site investigation studies or construction, it may be necessary to re-evaluate and modify or verify the conclusions and recommendations in writing. The data, recommendations, and conclusions provided in this report are based solely on the scope of work conducted by Haley & Aldrich and the sources of information referenced herein. This work was undertaken in accordance with generally accepted geotechnical engineering practice common to the local area. Recommendations presented in this report for foundation and floor drainage, moisture protection, waterproofing, and vapor intrusion address only the conventional geotechnical engineering related aspects of design and construction and are not intended to provide an environment that would prohibit infestation of mold or other biological pollutants. Our work scope did not include the development of criteria or procedures to minimize the risk of mold or other biological pollutant infestations in or near any structure. APPROXIMATE SCALE: 1 INCH = 2,000 FEET 42°26'46"N, 76°28'30"W FIGURE 1MAP SOURCE: USGS 0204866_000_LOCUS HALEYALDRICH\LREEDFEBRUARY 2024 SITE COORDINATES: PROJECT LOCUS CORNELL INDOOR SPORTS & RECREATION CENTER 544 CAMPUS ROAD ITHACA, NEW YORK @A @A @A @A @A @A @A @A @A @A !?!? !? !?!? APPROXIMATE LIMITS OF PROPOSED FIELDHOUSE CONSTRUCTION CAMPUS ROAD TOWER ROAD MANN DRIVEMANNCORNELL UNIV S Y N C H R O T R O N D R I V E KITEHILLDRIVEWING DRIVEARBORETUM ROAD HA-10 HA-2 HA-6 (OW)HA-3 HA-4 HA-9 HA-7 HA-5 HA-8 HA-1 LEGEND @A TEST BORING !?INFILTRATION TEST 0 150 300 SCALE IN FEET NOTES 1. ALL LOCATIONS AND DIMENSIONS ARE APPROXIMATE. 2. TEST BORINGS PERFORMED BY NOTHNAGLE DRILLING BETWEEN 11 AND 13 DECEMBER 2023 UNDER THE TECHNICAL OBSERVATION OF H & A OF NEW YORK. OW INDICATES OBSERVATION WELL INSTALLED IN COMPLETED BOREHOLE. 3. INFILTRATION TESTS PERFORMED BY NOTHNAGLE DRILLING BETWEEN 22 AND 23 JANUARY 2024 UNDER THE TECHNICAL OBSERVATION OF H & A OF NEW YORK. 3. PROPOSED LIMITS OF CONSTRUCTION ARE FROM DRAWING L2-01 "LAYOUT PLAN" BY SASAKI DATED 22 DECEMBER 2023. 4. AERIAL IMAGERY SOURCE: ESRI ROBINSON ALUMNI FIELDS CORNELL UNIVERSITY ITHICA, NEW YORK SITE AND SUBSURFACE EXPLORATION LOCATION PLAN FIGURE 2FEBRUARY 2024 GIS FILE PATH: \\haleyaldrich.com\share\CF\Projects\0204866\GIS\204866_CORNELL.aprx - USER: gwilde - LAST SAVED: 2/1/2024 6:58 PMB-2/A B-1 B-4 B-3 B-5/A 3. INFILTRATION TESTS PERFORMED BY NOTHNAGLE DRILLING BETWEEN 22 AND 23 JANUARY 2024 UNDER THE TECHNICAL OBSERVATION OF H & A OF NEW YORK. 4. PROPOSED LIMITS OF CONSTRUCTION ARE FROM DRAWING L2-01 "LAYOUT PLAN" BY SASAKI DATED 22 DECEMBER 2023. 5. AERIAL IMAGERY SOURCE: ESRI APPENDIX A Logs of Previous Explorations 7 Graphic from boring report, 2018, provided by Rich Gallagher. LEGEND ANDNOTESC100SealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH04.19.2024DAHOBBDAH1183528020.00 (TGM #E22-09) EXISTINGCONDITIONSPLANC101SealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH EROSION ANDSEDIMENT CONTROLPLANCONSTRUCTION PHASEC102 ASealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH EROSION ANDSEDIMENT CONTROLPLANSTABILIZATION PHASEC102 BSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH Indoor Sports and RecreationCenter & Field HockeyUTILITYDEMOLITIONPLANC103SealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH UTILITYPLANC104SealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH DRAINAGEPLANC105SealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH UTILITYDETAILSC201SealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH UTILITYDETAILSC202STORMWATERMANAGMENTPRACTICE:BIORETENTIONFILTERPROJECT ID: SPDESNYR-XXXXXXMUST BE MAINTAINED INACCORDANCE WITH O&M PLAN. DO NOT REMOVE OR ALTER.STORMWATERMANAGMENTPRACTICE:HYDRODYNAMICSEPARATORPROJECT ID: SPDESNYR-XXXXXXMUST BE MAINTAINED INACCORDANCE WITH O&M PLAN. DO NOT REMOVE OR ALTER.STORMWATERMANAGMENTPRACTICE:BELOW GRADEDETENTION SYSTEMPROJECT ID: SPDESNYR-XXXXXXMUST BE MAINTAINED INACCORDANCE WITH O&M PLAN. DO NOT REMOVE OR ALTER. FOR MAINTENANCE CALL 1.800.33 8 .11 2 2 www.ContechES.comTMCl ean water starts here®BBFLOWAASealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH ESCDETAILSC203···SealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH UTILITYPROFILESC301SealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:DRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTIONARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'04.19.2024DAHOBB1183528020.00 (TGM #E22-09)DAH EXISTING WALLPROTECT INPLACE, TYP.EXISTING TREES TO BE REMOVED, TYP.R&S GRANITE CURB, TYP.R&D CONCRETE PAVEMENT &UNDERLYING SLAB, TYP.R&D SYNTHETIC TURF, INFILL,ELASTIC LAYER. R&S DRAINAGESTONE FOR LATER USER&D GRASS LAWN, TYP.R&D GRAVEL, TYP,P&S LIGHT POLE,FIXTURE, ANDFOUNDATIONR&D CHAIN-LINK FENCE, TYP.R&S SCOREBOARD,R&D SCOREBOARD SUPPORT POLES,FRAMING AND FOOTINGSP&S ELECTRIC ANDTRANSFORMERP&S ABOVE-GROUNDTANK AND PUMPR&S MONUMENTR&S BENCHP&S UTILITY VAULTSR&D ASPHALTPAVEMENT, TYP.R&D CHAIN-LINKFENCE, TYP.R&D CHAIN-LINKFENCE, TYP.R&D CHAIN-LINK FENCE, TYP.SAWCUT PAVEMENT, TYP.SAWCUT PAVEMENT, TYP.P&S CONCRETE SEATWALLSAWCUT PAVEMENT, TYP.SAWCUT PAVEMENT, TYP.SAWCUT PAVEMENT, TYP.R&S EXISTING BOLLARDLIGHTS AND DELIVER TOCLIENT, TYP.R&S BLEACHERSR&D EXISTING LIGHT POLEAND FOUNDATION, TYP.R&D FLUSH 12"CONCRETE CURB, TYP.R&S GRANITE CURB, TYP.DO NOT DISTURB EXISTINGSTORMWATER PRACTICELIMIT OF WORKLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKTOWN OF ITHACACITY OF ITHACAMUNICIPAL BOUNDARYSITE PROTECTION &REMOVALS PLANL1-01CLEAR AND GRUB. REMOVETOPSOIL AND STORE FORREUSEREMOVE EXISTING TREEREMOVE AND DISPOSEGRAVELPROTECT EXISTING UTILITYSTRUCTUREREMOVE & DISPOSESAWCUT PAVEMENTREMOVE & SALVAGE EXISTINGBOLLARD LIGHT ANDFOUNDATIONREMOVE AND DISPOSECONCRETE PAVEMENT &UNDERLYING SLABLEGENDDESCRIPTIONSYMBOLSABBREVIATIONDESCRIPTIONGENERALTYPTYPICALR&DREMOVE AND DISPOSER&SREMOVE AND SALVAGEP&SPROTECT AND SUPPORTREMOVE & SALVAGE SITEFEATUREREMOVE AND DISPOSEARTIFICIAL TURF SYSTEMREMOVE AND DISPOSE ASPHALTPAVEMENT & UNDERLYING SLABPROTECT & SUPPORT SITEFEATUREPLANTED AREA TO REMAINLIMIT OF WORK (LOW)MUNICIPAL BOUNDARYREMOVE & DEMOLISH EXISTINGLIGHT POLE AND FOUNDATIONREMOVE & SALVAGESILT LOG, REFER TO CIVILDRAWINGSPROTECT AND SUPPORTCONCRETE PAVEMENTSITE PREPARATION & REMOVALS NOTES:1.ALL DISTURBED AREAS SHALL BE RESTORED TOTHEIR ORIGINAL CONDITION, UNLESS OTHERWISENOTED.2.CONTRACTOR SHALL PROTECT ALL EXISTINGBUILDINGS, PAVEMENT, ANDABOVE/UNDERGROUND STRUCTURES THAT ARENOT BEING DEMOLISHED.3.DAMAGE TO AREAS OUTSIDE OF THE LIMIT OFWORK CAUSED BY WORK UNDER THIS CONTRACTSHALL BE REPAIRED BY THE CONTRACTOR AT NOADDITIONAL COST.4.STAGING AND INSTALLATION SHOULD TAKEPLACE ONLY WITHIN THE LIMIT OF WORK ASDEFINED ON THE DRAWINGS AND ADJACENTASPHALT OR CONCRETE AREAS AS NEEDED. NOSTAGING SHALL TAKE PLACE IN ADJACENTPLANTING AREAS. COORDINATE STAGING AREASWITH OWNER.5.REMOVE ALL EXISTING CONSTRUCTIONSNECESSARY FOR THE COMPLETION OF THE WORKAS DEPICTED ON THE DRAWINGS.6.IN ALL AREAS DESIGNATED FOR TYPICAL(NON-HAND EXCAVATED) PAVING REMOVAL,REMOVE EXISTING MATERIAL TO A MIN. DEPTHOF 10 INCHES/250MM BELOW EXISTING GRADEOR TO BOTTOM OF EXISTING BASE AGGREGATE,WHICHEVER IS DEEPER.7.PROTECT ALL EXISTING PLANT MATERIAL FROMDAMAGE AND ALL PLANTING SOIL FROMCONTAMINATION DURING CONSTRUCTION.8.IF EXISTING IRRIGATION PIPING IS FOUND,REMOVE IRRIGATION HEADS,VALVES, LATERALSAND MAINLINES AS NECESSARY. CAP END OFUNDISTURBED MAINLINES AND LATERALS.ENSURE SYSTEM REMAINS OPERATIONAL TOEXISTING PLANTING AREAS NOT WITH INDISTURBED AREA. RESTORE CONNECTIONS AFTERCONSTRUCTION COMPLETION.9.PRESERVE AND PROTECT ALL EXISTING SITEFURNISHINGS OR HARDSCAPE TO REMAIN.REMOVE ALL FURNISHINGS AS IDENTIFIED ONDEMOLITION PLAN, INCLUDING ANY FOUNDATIONOR OTHER FEATURES ASSOCIATED WITH THEFURNISHING.10.NECESSARY DISCONNECTS AND ALTERATIONS TOEXISTING MECHANICAL AND ELECTRICAL SYSTEMSSHALL BE INCLUDED AS NEEDED. PATCH ASREQUIRED ALL CONSTRUCTIONS TO REMAIN INACCORDANCE WITH THE CONTRACT DRAWINGS.11.ALL REMOVALS AND SALVAGE, UNLESSSPECIFICALLY NOTED OR REQUESTED BY THEOWNER, SHALL BECOME THE PROPERTY OF THECONTRACTOR.12.VERIFY WITH LANDSCAPE ARCHITECT PRIOR TOREMOVAL, ANY ADDITIONAL LANDSCAPE ITEMSNOT ANNOTATED ON THE LANDSCAPE DRAWINGSTHAT NEED TO BE REMOVED TO COMPLETESCOPE OF WORK.13.ALL STRUCTURAL SYSTEMS AND HARDSCAPEELEMENTS SHALL BE MAINTAINED IN FIELDUNLESS OTHERWISE NOTED. THE CONTRACTORSHALL REINSTALL ALL TEMPORARILY REMOVEDFURNISHINGS TO THEIR ORIGINAL LOCATION ANDPLACEMENT IN FIELD EXISTING CONDITION,UNLESS OTHERWISE NOTED.14.ALL ROOTS FOUND BELOW PAVING TO BEREMOVED SHALL BE CUT AND REMOVED AMINIMUM OF FOUR INCHES/100 MILLIMETERBELOW THE DEPTH OF EXCAVATION OR AT THEEDGE OF THE LIMIT OF WORK. ALL ROOTPRUNING TO BE PERFORMED BY CERTIFIEDARBORIST.15.ALL SURFACES CALLED FOR SANDBLASTING TO BEREVIEWED IN MOCKUP FIRST WITH LANDSCAPEARCHITECT.16.ALL SURFACES CALLED FOR REPAINTING TO BESTRIPPED, CONCRETE SANDBLASTED, METALSTRIPPED, BEFORE PRIMING AND REPAINTING.17.ALL TREES TO BE REMOVED TO BE CUT AT BASE,STUMP TO BE GRINDED, AND ANY ROOTS LARGERTHAN 2 INCHES/50 MILLIMETER IN DIA. WITHIN A5 FOOT/1.5 METER RADIUS OF THE CENTER OFTHE TRUNK TO BE REMOVED.18.THE LIMIT OF WORK LINE FOR THE AREA TO BECLEARED AND GRUBBED SHALL BE THE SAME ASTHE LIMIT OF WORK LINE NECESSARY FORGRADING PURPOSES, I.E., THE GRADING LIMITSAROUND THE PERIMETER OF THE PROJECT AREA.19.THE DISPOSAL OF ALL DEMOLISHED MATERIALS ISTHE RESPONSIBILITY OF THE CONTRACTOR ANDMUST BE OFF-SITE IN ACCORDANCE WITH ALLFEDERAL, STATE, AND LOCAL MUNICIPALREQUIREMENTS.20.REMOVE AND RESET ALL REGULATORY SIGNAGEPER CITY REQUIREMENTS.21.ANY DAMAGED UTILITIES MUST BE RETURNED TOPRE-DAMAGED CONDITION, OR BETTER.22.ALL EXISTING WATER SERVICES SHALL BE SHUTOFF AND CAPPED AT THE WATER MAIN. EXISTINGSERVICE LINES, VALVES, AND VALVE BOXESSHALL BE REMOVED.23.SEE CIVIL SERIES DRAWINGS FOR UTILITYINFRASTRUCTURE TO BE REMOVED. THISDRAWING IS NOT A COMPREHENSIVEREPRESENTATION OF ALL SITE ITEMS TO BEREMOVED OR PROTECTED. ANY ADDITIONALSERVICES LOCATED DURING CONSTRUCTION NOTINDICATED TO REMAIN SHALL ALSO BE BROUGHTTO IMMEDIATE ATTENTION OF THE SITEARCHITECT.24.ALL STREET LIGHTING AND TRAFFIC SIGNALCONDUITS SHALL REMAIN IN PLACE AND BEPROTECTED UNLESS OTHERWISE NOTED. ANYDAMAGE TO THESE CONDUITS SHALL BEREPAIRED BY THE CONTRACTOR.Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L1-01_SITE PROTECTION & REMOVALS PLAN.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20' ALUMNI FIELD PARKING LOTINDOOR SPORTS &RECREATION CENTERFFE 878.33PARKING LOTCHARLES F. BERMAN FIELDWEILLHALLFIELD EL. 875ALUMNI FIELD+/- 382'26.00'20.00'29.50' 26.00'20.00'+/- 225' 11.33' 20.00'ACCESS FROMCAMPUS ROADACCESS FROMTOWER ROADVEHICULAR ACCESS TO FIELDACCESS FROMTOWER ROADVEHICULAR ACCESSVIA ROLL UP DOORACCESS FROMCAMPUS ROADFLUSH CURBMOUNTABLECURB20.80' 50.68'HYDRANTHYDRANT20.00'LIMIT OF WORKLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKTOWN OF ITHACACITY OF ITHACAMUNICIPAL BOUNDARYLIMIT OF WORKSYMBOLSDESCRIPTIONLEGENDFIRE APPARATUS ACCESSFIRE ACCESS ROUTESL1-02Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L1-02_FIRE ACCESS ROUTES.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20' ALUMNI FIELD PARKING LOTINDOOR SPORTS &RECREATION CENTERFFE 878.33PARKING LOTCHARLES F. BERMAN FIELDWEILLHALLFIELD EL. 875ALUMNI FIELDALUMNI FIELD PARKING LOTINDOOR SPORTS &RECREATION CENTERFFE 878.33PARKING LOTCHARLES F. BERMAN FIELDWEILLHALLFIELD EL. 875ALUMNI FIELDALUMNI FIELD PARKING LOTINDOOR SPORTS &RECREATION CENTERFFE 878.33PARKING LOTCHARLES F. BERMAN FIELDWEILLHALLFIELD EL. 875ALUMNI FIELDALUMNI FIELD PARKING LOTINDOOR SPORTS &RECREATION CENTERFFE 878.33PARKING LOTCHARLES F. BERMAN FIELDWEILLHALLFIELD EL. 875ALUMNI FIELDALUMNI FIELD PARKING LOTINDOOR SPORTS &RECREATION CENTERFFE 878.33PARKING LOTCHARLES F. BERMAN FIELDWEILLHALLFIELD EL. 875ALUMNI FIELD360.00, TYP.15.00,TYP.LOCATION TO BE VIFLOCATION TO BE VIFLOCATION TO BE VIFR3.00'R3.00'R20.0 0 'R12.00'R 1 2 . 0 0 'R8.00'R5.00'R35.00'R28.00'R 3 . 0 0 ' R3.0 0 'LOCATIONTO BE VIFALIGN12.0012.0026.00 26.0020.00R10.00'9.766.00, TYP.9.8320.00S89° 45' 34.30"W115.02S89° 30' 53.06"E424.24LOCATIONTO BE VIFLOCATION TO BE VIFLOCATION TO BE VIFLOCATION TO BE VIFLOCATION TO BE VIFLOCATION TO BE VIFLOCATION TO BE VIFLOCATION TO BE VIFLOCATION TO BE VIFLOCATION TO BE VIFALIGN10.528.008.03 22.508.00R10 . 0 0 '182.688.00N0° 29' 38.63"E14.30 N0° 29' 42.52"E32.10N89° 41' 57.70"E192.99N85° 24' 33.61"E47.43N 3 5 ° 4 7 ' 5 6 . 1 3 " E 24 . 3 1 S89° 34' 40.11"W66.9526.0094.6015.00 N0° 22' 38.59"E 306.70 68.03N81° 05' 49.46"E102.63L=12.41, R=8.00D=88.9062.9210.16 20.001.50, TYP.R8.00'LOCATIONTO BE VIFLOCATIONTO BE VIFLOCATIONTO BE VIFLOCATIONTO BE VIFLOCATIONTO BE VIFLOCATIONTO BE VIFN0° 01' 15.60"W 56.66N0° 38' 07.75"W 20.69N0° 16' 40.68"W 133.66 N0° 21' 09.68"W 129.53N0° 28' 58.95"E12.45N0° 13' 37.43"W 55.31ALIGN 8.00R 3 . 0 0 '20.00160.00105.00, TYP. (SPORTS LIGHT POLE)L=64.60,R=39.10D=94.66N:891674.73E:849185.88N:891654.45E:849180.20N:891653.72E:849178.35N:891574.87E:849179.52N:891652.37E:848903.95N:891684.47E:848904.23N:891285.01E:848900.78N:891244.92E:848942.00N:891245.94E:849134.99N:891249.73E:849182.27N:891241.36E:849182.21N:891259.87E:849182.33N:891231.19E:849182.14N:891275.75E:849283.72N:891241.85E:849297.24N:891230.03E:849317.71N:891234.23E:849352.70N:891240.58E:849505.68N:891236.66E:849515.53N:891256.38E:849529.75N:891256.87E:849596.69N:891263.44E:849604.65N:891318.75E:849604.43N:891460.73E:849603.74N:891534.33E:849603.38N:891594.39E:849603.09N:891615.07E:849602.86N:891671.73E:849602.84N:891536.12E:849392.26N:891537.86E:849184.16N:891331.20E:849604.54N:891557.24E:849378.84N:891522.91E:849416.5227.506.00 R5.00 ' R 3 . 0 0 'R5.00'4.00,TYP.N:891537.90E:849179.12N:891548.73E:849438.978.00 R 3 . 0 0 ' R 5 . 0 0 '8.330.50N:891269.57E:849554.74N:891278.45E:849539.366.00, TYP.1.50N:891243.44E:849533.7020 . 3 1N:891218.07E:849315.14N:891231.50E:849237.2516.21R8.00'R3.00'R4.93 'R2.00' 3.12 13.9655.4121.80LOCATIONTO BE VIFLOCATIONTO BE VIFN:891647.19E:849160.95N:891649.26E:848918.29N:891275.94E:848915.11N:891273.88E:849157.771.33, TYP.14.19R13.33'R13.33'N:891241.16E:849164.93N:891282.98E:849276.03N:891285.20E:849200.14N:891521.00E:849425.1112.00, TYP.N:891512.56E:849396.55R3.00'R 3 . 0 0 ' R 8 . 0 0 'LOCATION TO BE VIF10.00N:891650.92E:849199.63N:891629.22E:849234.472. 0 0 , TY P .12.00, TYP.6.00, TYP.N:891616.16E:849262.02N:891633.12E:849227.48N:891612.91E:849263.64N:891597.06E:849296.18N:891593.14E:849303.17N:891590.27E:849308.29N:891572.42E:849336.1127.07N:891558.91E:849181.89N:891258.01E:848986.304.00,TYP.30.00, TYP.210.00, TYP.N0° 29' 06.94"E 136.49 S60° 46' 39.03"E242.37N89° 08' 45.21"E162.85S59° 59' 50.26"E23.64N:891247.80E:849321.247.00, TYP.N:891224.73E:849288.4417.5020.00N:891267.62E:849278.883.466. 0 0 , T Y P .N:891267.84E:849267.141.50,TYP.N:891251.77E:849284.36R2.00'N:891274.18E:849219.22N:891271.75E:849220.28N:891257.14E:849204.7523.5620.0N:891259.74E:849270.78N:891252.40E:849254.71ALIGNLOCATIONTO BE VIFALIGNR3.00'R3.00'11.33 N:891505.70E:849583.409.0 0 8.0011.788. 0 0 ALIGNLOCATION TO BE VIFLIMIT OF WORKLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKTOWN OF ITHACACITY OF ITHACAMUNICIPAL BOUNDARY5/4/2023 9:55:01 AMBEARING DISTANCE CENTERLINE (CL)LEGENDLIMIT OF WORK (LOW)DESCRIPTIONSYMBOLS694.56'N01°16'44"ER1' -0 "5.00'RADIAL DIMENSIONLINEAR DIMENSIONARC LENGTH DIMENSIONABBREVIATIONDESCRIPTIONGENERALTYPTYPICALVIFVERIFY IN FIELDNNORTHEEASTSSOUTHWWESTO/CON CENTER1'-312"N:10541359.19E:3297858.87NORTHING/EASTING COORDINATESMUNICIPAL BOUNDARYLAYOUT PLANL2-01LAYOUT NOTES:1.VERIFY LOCATION OF ALL BUILDINGS, WALLS,ROADS AND CURBS AFFECTING LANDSCAPE SCOPEOF WORK WITH ARCHITECTURAL AND CIVILENGINEER'S DRAWINGS.2.VERIFY LOCATION OF ALL VAULTS, ELECTRICALDUCT BANKS, MANHOLES, CONDUIT AND PIPING,DRAINAGE STRUCTURES AND OTHER UTILITIESWITH THE APPROPRIATE ENGINEERINGDRAWINGS.3.TAKE ALL DIMENSIONS FROM BACK OF CURB,WALL OR BUILDING OR TO CENTERLINE OFCOLUMNS OR TREES UNLESS OTHERWISE NOTED.ALL MEASUREMENTS TO DESIGNATEDCENTERLINE(S).4.TAKE ALL DIMENSIONS PERPENDICULAR TO ANYREFERENCE LINE, WORK LINE, FACE OF BUILDING,FACE OF WALL, OR CENTERLINE.5.ALL DIMENSIONS TAKEN TO CENTERLINE OFBUILDING COLUMN SHALL MEAN THE FIRST ROWOF COLUMNS CLOSEST TO THE FACE OF THEBUILDING. SEE ARCHITECT'S DRAWINGS FORCORRESPONDING COLUMN LINES.6.ALL ANGLES TO BE 90 DEGREES AND ALL LINESOF PAVING AND FENCING TO BE PARALLELUNLESS NOTED OTHERWISE. MAINTAINHORIZONTAL ALIGNMENT OF ADJACENTELEMENTS AS NOTED ON THE DRAWINGS.7.REFERENCE TO NORTH REFERS TO TRUE NORTH,REFERENCE TO SCALE IS FOR FULL-SIZEDDRAWINGS ONLY. DO NOT SCALE FROM REDUCEDDRAWINGS.8.DIMENSIONS TAKE PRECEDENCE OVER SCALESSHOWN ON DRAWINGS.9.NOTES AND DETAILS ON SPECIFIC DRAWINGSTAKE PRECEDENCE OVER GENERAL NOTES ANDTYPICAL DETAILS.10.DO NOT INSTALL ANY WORK ON STRUCTUREPRIOR TO REVIEW OF WATERPROOFING BYARCHITECT.11.ALL CONCRETE SLABS AND RAMP OR STEPFOOTINGS SHALL BE DOWELED INTO ABUTTINGWALLS, FOUNDATIONS AND FOOTINGS USINGBARS OF THE SAME SIZE AND SPACING UNLESSNOTED OTHERWISE. SEE JOINTING DETAILS.12.WHERE NOT SHOWN ON LANDSCAPE DRAWINGS,SEE CIVIL ENGINEER'S DRAWINGS FOR ROADWAYCENTERLINES, BUILDING SETBACKS ANDBENCHMARKS.13.ALL COORDINATES ARE BASED ON AN ASSUMEDGRID SYSTEM. COORDINATES REFER TO THECENTER OF STRUCTURES UNLESS OTHERWISENOTED OR DETAILED.Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L2-01_LAYOUT PLAN-1.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20' ALUMNI FIELD PARKING LOTINDOOR SPORTS &RECREATION CENTERFFE 878.33PARKING LOTCHARLES F. BERMAN FIELDWEILLHALLFIELD EL. 875ALUMNI FIELDLIMIT OF WORKLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKTOWN OF ITHACACITY OF ITHACAMUNICIPAL BOUNDARYF1F2F3F4ASPHALT PAVING, TYP.RIVERSTONE DRIPEDGE, TYP.STEEL EDGING, TYP.STABILIZEDSTONEDUSTPAVING, TYP.PRECAST CONCRETESEATING, TYP.CONCRETE PAVING,HEAVY-DUTY, TYPCONCRETE PAVING, TYP.CONCRETE PAVING,HEAVY-DUTY, TYPPRECAST CONCRETESEATING, TYPCONCRETE PAVINGHEAVY DUTY, TYP.PERIMETER CONCRETETURF CURBFLUSH GRANITECURBFLUSH GRANITECURBSYNTHETIC TURF FIELD6-FOOT FENCE AT SYNTHETICTURF PERIMETER CURBMULTI-PURPOSE TURFFIELD STRIPING, TYP.SEE SPECIFICATIONS30' HIGH END OF FIELDNETTING, TYP. SEESPECIFICATIONSSCOREBOARDSPORTS LIGHT POLE(F1,F2,F3,F4), TYP.42" BLACK VINYLCHAIN LINK FENCEHYDRANTHYDRANTHEAVY-DUTY CONCRETE PAD FOREXISTING DUMPSTERSBIKE RACK, TYP.PEDESTRIAN LIGHTPOLE, TYP. SEESPECIFICATIONSLIGHT POLEFOUNDATION - INPLANTING, TYP.BIKE RACK, TYP.EXISTING SPORTSLIGHTING TO REMAINSTABILIZED STONEDUSTPAVING, TYP.COLORED CONCRETEPAVING W/ SILICA CARBIDEMOUNTABLE GRANITECURBFLUSH GRANITECURBEXISTING CONCRETESEATWALL TO REMAINFIELD NET POSTPA-03FN-01FN-02FD-01FD-02SW-01PA-09EG-02EG-01PA-02SF-01PA-04PA-05PA-02SW-01EG-02PA-05SF-01EG-08PA-02EG-02PA-07PA-01FD-07SF-02PA-06FN-03SMOOTH CONCRETEPAVER BANDS, TYPAPPROXIMATE EXTENTS OFSNOWMELT SYSTEM, TYP. REFER TOMS1-01 FOR MORE DETAILSBOLLARD, TYP.PA-10COLORED CONCRETEPAVING W/ SILICA CARBIDEPA-04IN-KIND REPLACEMENT OFEXISTING ASPHALTPAVEMENT IN PARKING LOTIN-KIND REPLACEMENT OFEXISTING ASPHALTPAVEMENT IN THE ALUMNIFIELD PARKING LOTIN-KIND REPLACEMENT OFEXISTING CONCRETEPAVEMENT IN WALKWAYMATERIALS NOTES:1.TYPES OF MATERIALS ARE NOTED IN THE LEGEND.SEE DETAILS AND SPECIFICATIONS FOR FINISHES.2.ALL LANDSCAPE MATERIALS AND LAYOUT SHALL BECOORDINATED WITH CIVIL DRAWINGS ANDARCHITECTURE CONSTRUCTION PACKAGESASPHALT PAVINGCONCRETE PAVING,HEAVY-DUTYCONCRETE PAVINGSTABILIZED STONEDUSTPAVINGLEGENDLIMIT OF WORK (LOW)PA-01PAVING ASSEMBLIESSYMBOL:DESCRIPTION:SEEL8-01PA-02PA-03PA-04PA-05PA-06COLORED CONCRETE PAVINGWITH SILICA CARBIDERIVERSTONE DRIP EDGEEXTENTS OF SNOW MELTSYSTEMSEEL8-02EDGE CONDITIONSSYMBOL:DESCRIPTION:GRANITE MOUNTABLE CURBGRANITE FLUSH CURBSTEEL EDGINGEG-01EG-02EG-08EXPANSION JOINTJT-01CONTROL JOINTSEATWALLSSYMBOL:DESCRIPTION:PRECAST CONCRETE SEATINGSW-01SEEL8-04SITE FURNISHINGSSYMBOL:DESCRIPTION:BIKE RACKSF-01SEEL8-04BOLLARDLIGHT POLE FOUNDATION - INPLANTINGSF-02MULTI-PURPOSE FIELDSYMBOL:DESCRIPTION:SYNTHETIC TURF FIELDFN-04FLAGPOLEFD-01SYNTHETIC TURF PERIMETERCURBFD-02SEEL8-10SEEL8-11PA-09HEAVY-DUTY CONCRETE PADFOR EXISTING DUMPSTERSFENCING AND NETTINGSYMBOL:DESCRIPTION:42" BLACK VINYL CHAIN LINKFENCEFN-026-FOOT FENCE AT SYNTHETICTURF PERIMETER CURBFN-01MUNICIPAL BOUNDARYSCOREBOARDFD-07JT-03PA-07FIELD NET POSTFN-03PA-10SMOOTH CONCRETE PAVERBANDPAVING JOINTSSYMBOL:DESCRIPTION:SEEL8-01MATERIALS PLANL3-01Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L3-01_MATERIALS PLAN-1.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20' ALUMNI FIELD PARKING LOTINDOOR SPORTS &RECREATION CENTERFFE 878.33PARKING LOTCHARLES F. BERMAN FIELDWEILLHALLFIELD EL. 875ALUMNI FIELDFG 0.50%SG 0.50%20.00FG 875.55TOS: 875.33TSG: 874.6610.00FG: 875.10, TOS: 874.88, TSG: 873.21+ (875.70)(875.69)+(876.17)3.84%+ 877.45+ 878.10+ 878.25+ 878.02+ 877.65+ 877.25+ 877.903.33%1.5%0.50%+ 877.49+ 877.191.5%1.75%5 STAIRS+ 877.75877.70 ++ 877.65+ 877.321.75%+ 878.91+ 879.00+ 878.302.3%1%1.59%+ 875.491.75%1. 7 5 %1%+ 877.70+ 875.80+ 877.27+ 878.251.75%878.10+878.10+878.20++ 878.80+ 878.52878.10++877.651%+877.65+ 876.40+ 876.191.75%+ 877.45+ 877.451. 7 5 %+ 876.85877.95++ 878.85+ 878.851.5%1.5%+880.201.75%+ 878.25878.25 +++877.65+(TC 878.36)++ (BC 877.57)+ (BC 877.51)(878.26)TC 878.10BC 877.60+877.95+877.95+878.10+877.73+877.85+878.25+(878.20)++ 878.251. 5 %+(TC 878.70)++878.60(TC 880.10)+(TC 880.30)++879.55(879.70)++879.251.75%878.10 +878.10 ++++(879.28)+(BC 879.33)+1.75%875.30+(877.90)+878.15+(878.09)++ 875.25+ 877.71+ 877.47(878.15)+(878.16)++ 877.96+ 877.97+ 878.75+ 878.75880878(879.20)(879.25) +878877878878HPS 875.950.67%LPS 874.350.67%FG 874.30FG 874.15874.5+ LPFG 875.1020.0020.0020.0020.0020.0020.0020.0020.0020.00875875+ 877.75877.75 +877.75 ++ 877.30+ 877.00(BC 877.70)(879.69)(878.96)RIM 877.82RIM 878.73+ 877.61+ 875.49+ 875.33+ 875.33RIM 878.02RIM 875.00RIM 874.35RIM 878.61RIM 878.87RIM 877.90LP/RIM 877.35RIM 877.40RIM 877.05RIM 874.40REFER TO C105 FOR UTILITYSTRUCTURE AND SYSTEMINFORMATIONRIM 878.35RIM 878.15(BC 876.87)+(BC 876.49)+(876.00)+(875.87)+(TC 876.89BC 876.54)+(TC 876.23BC 876.12)+8 6 . 0 °876.45876.396.0+ 876.19+ 876.33+ 876.101.0%+ 875.90+ 875.90LP 874.65+(879.13)+(879.06)+(879.05)+(879.22)+(879.22)+(878.87)+(879.29)1%1%+ 878.25+ 878.93+ 878.86+ 878.85+ 879.02+ 879.02+(879.29)+(879.17)+(879.42)879879 1.75%FG: 875.00, TOS: 874.78, TSG: 874.11FG 0.50%SG 0.50%FG: 875.20, TOS: 874.98, TSG: 873.31 FG: 875.30, TOS: 875.08, TSG: 873.41 FG: 875.40, TOS: 875.18, TSG: 873.51FG: 875.50, TOS: 875.28, TSG: 873.61FG: 875.55, TOS: 874.33, TSG: 873.66FG: 875.55, TOS: 874.33, TSG: 873.66FG: 875.50, TOS: 875.28, TSG: 873.61FG: 875.40, TOS: 875.18, TSG: 873.51FG: 875.30, TOS: 875.08, TSG: 873.41FG: 875.20, TOS: 874.98, TSG: 873.31FG: 875.10, TOS: 874.88, TSG: 873.21FG: 875.00, TOS: 874.78, TSG: 874.11 FG: 875.10, TOS: 874.88, TSG: 873.21 FG: 875.00, TOS: 874.78, TSG: 874.11 FG: 875.20, TOS: 874.98, TSG: 873.31 FG: 875.30, TOS: 875.08, TSG: 873.41 FG: 875.40, TOS: 875.18, TSG: 873.51FG: 875.50, TOS: 875.28, TSG: 873.61FG: 875.55, TOS: 874.33, TSG: 873.66FG: 875.55, TOS: 874.33, TSG: 873.66FG: 875.50, TOS: 875.28, TSG: 873.61FG: 875.40, TOS: 875.18, TSG: 873.51FG: 875.30, TOS: 875.08, TSG: 873.41FG: 875.20, TOS: 874.98, TSG: 873.31FG: 875.10, TOS: 874.88, TSG: 873.21FG: 875.00, TOS: 874.78, TSG: 874.11 FG 875.20FG 875.30FG 875.40FG 875.50FG 875.10FG 875.20FG 875.30FG 875.40FG 875.50FG 875.55TOS: 875.33TSG: 874.66FG 875.10FG 875.20FG 875.30FG 875.40FG 875.50FG 875.10FG 875.20FG 875.30FG 875.40FG 875.50877876875875874LIMIT OF WORKLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKTOWN OF ITHACACITY OF ITHACAMUNICIPAL BOUNDARY5110.00TSBSVERIFY IN FIELDSYMBOLDESCRIPTIONSPOT ELEVATIONFINISHED FLOOR ELEVATIONTOP AND BOTTOM OF STAIRCONTOUR MAJORCONTOUR MINORVIFFFETCBCTOP AND BOTTOM OF CURBTWBWTOP AND BOTTOM OF WALLHPLPSLOW POINT OF SWALEHIGH POINTCONTOUR/ELEVATIONEXISTINGGRADE BREAKRIM ELEVATIONRIM(5)UTILITY STRUCTURE, SEECIVIL DRAWINGSNOTE: "+" IDENTIFIES LOCATION REQUIRING SPOTELEVATION, TYP.LPLOW POINTHPSHIGH POINT OF SWALETRENCH DRAIN, SEE CIVILDRAWINGSFINISHED / FIELD GRADEFGTOP OF ELASTIC LAYERTELTOP OF STONETOSTOP OF SUBGRADETSGLIMIT OF WORK (LOW)MUNICIPAL BOUNDARYLEGENDGRADING NOTES:1.FOR EXISTING TOPOGRAPHY INCLUDING GRADES,UTILITIES, PROPERTY LINES, LIMITS OFROADWAYS, CURBS AND GUTTERS, EXISTINGTREES, ETC., REFER TO THE SURVEY.2.SAWCUT AND REMOVE ALL EXISTING PAVEMENTIN AREAS WHERE THE PROPOSED GRADES ARELESS THAN 1 INCH/25 MILLIMETER GREATERTHAN THE EXISTING GRADES.3.PATHWAY LONGITUDINAL SLOPES SHALL NOTEXCEED 5%. PATHWAY CROSS-SLOPES AND PLAZASLOPES SHALL NOT EXCEED 2% IN ANYDIRECTION. ADA RAMP LONGITUDINAL SLOPESHALL NOT EXCEED 8.3%. ALL PAVED AREASSHALL BE SLOPED TO DRAIN WITH A MINIMUMSLOPE OF 0.5%. PLANTED AREAS SHALL HAVE AMINIMUM SLOPE OF 2% AND A MAXIMUM SLOPEOF 33%. CONTRACTOR TO NOTIFYENGINEER/LANDSCAPE ARCHITECT/OWNERIMMEDIATELY OF ANY DISCREPANCIES BETWEENTHESE RULES AND GIVEN SPOT GRADES.4.ALL FINISHED GRADES SHALL PROVIDE FORNATURAL RUNOFF OF WATER WITHOUT LOWSPOTS OR POCKETS. SET FLOW LINESACCURATELY AND PROVIDE A MINIMUM 1% AND AMAXIMUM 3:1 (33%) GRADIENT UNLESSOTHERWISE NOTED.5.HOLD FINISHED GRADES INCLUDING THE MULCHLAYER FOR SHRUB AND GROUNDCOVER AREAS1/4 INCH/7 MILLIMETER BELOW TOP OFADJACENT PAVEMENT, CURBS, OR HEADERSUNLESS OTHERWISE NOTED ON THE DRAWINGS.6.GRADUALLY ROUND OFF TOPS AND TOES OF ALLPLANTED SLOPES TO PRODUCE A SMOOTH ANDNATURAL APPEARING TRANSITION BETWEENRELATIVELY LEVEL AREAS AND SLOPES.7.RETAIN A 1 FOOT/300 MILLIMETER MINSHOULDER (5% SLOPE OR LESS) ADJACENT TOALL WALKWAYS AND UTILITY TABS, UNLESSOTHERWISE NOTED.8.VERIFY ACCURACY OF ALL EXISTING GRADES ATAREAS TO REMAIN, PRIOR TO STARTINGCONSTRUCTION OF ADJUSTMENTIMPROVEMENTS. NOTIFY CLIENT AND DESIGNTEAM OF DISCREPANCIES.9.HOLD TOPS OF WALLS LEVEL UNLESS NOTEDOTHERWISE.10.COORDINATE ALL EXISTING MANHOLES, CATCHBASINS, UTILITY BOXES, CLEANOUTS, VAULTS,FIRE HYDRANTS, ETC., TO MATCH NEW FINISHEDGRADES.11.IN FILL AREAS WHERE PROPOSED GRADES ARE 1TO 3 INCHES/25-75 MILLIMETER HIGHER THANTHE EXISTING PAVEMENT, THE PROPOSEDGRADES SHALL BE MET BY ADDING PAVEMENTOVERLAYS (1.5 INCH/40 MILLIMETER MAXIMUMTHICKNESS EACH LIFT) TO EXISTING PAVEMENT.12.SYNTHETIC TURF PERIMETER CURB SHALL NOTDEVIATE MORE THAN 18" IN 10 FEET AND SHALLNOT VARY FROM DESIGN GRADE BY MORE THAN18".13.SUBGRADE SHALL BE GRADED TO A TOLERANCEOF 14" FROM DESIGN GRADE WITHHYDRAULICALLY CONTROLLED LASER GRADINGAPPARATUS. THE GRADE SHALL NOT VARY MORETHAN 14" IN 10 FEET UNDER 10 FOOT STRAIGHTEDGE.14.PRIOR TO INSTALLATION OF GEOTEXTILE FABRIC,PANEL DRAINS, AND DRAINAGE STONE, SIGNOFFFROM ARCHITECT IS REQUIRED ON SUBGRADEFOR COMPACTION, PLANARITY, AND DESIGNGRADE COMPLIANCE.15.DRAINAGE STONE SHALL BE FINE GRADED TO ATOLERANCE OF 18" FROM DESIGN GRADE AND NOTVARY MORE THAN 18" WHEN MEASURE UNDER A 10FOOT STRAIGHT EDGE.GRADING PLANL4-01Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L4-01_GRADING PLAN.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20' ALUMNI FIELD PARKING LOTINDOOR SPORTS &RECREATION CENTERFFE 878.33PARKING LOTCHARLES F. BERMAN FIELDWEILLHALLFIELD EL. 875ALUMNI FIELDLIMIT OF WORKLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKTOWN OF ITHACACITY OF ITHACAMUNICIPAL BOUNDARYMAINTAIN EXISTING GRASS. DO NOTDISTURB STORMWATER PRACTICE(14) AG(14) AG(12) IS(6) BO(4) BO(2) BO(3) AO(5) UP(2) UP(3) AO(2) AO(6) BO(10) CN(3) AO(10) AA(11) MB(3) MB(6) MB(7) AL(8) AL(7) IR(1) IV2(37) PA(41) CS(51) CS(13) SK(51) SK(100)NFG(100)NFG(100)NFG(38) PA(47) MD(34) MD(22) AL(26) AL(11) IM(9) VDPLANTING NOTES:1.REFER TO L5-02, PLANTING SCHEDULE, FORLEGEND OF GROUNDCOVER AND PLANTSPECIES.2.PROVIDE MATCHING SIZES AND FORMS FOREACH SPECIES OF TREE INSTALLED ON GRID ORSPACED EQUALLY IN ROWS AS SHOWN ONDRAWINGS, SUBJECT TO REVIEW BY THELANDSCAPE ARCHITECT.3.PROVIDE MATCHING SIZES AND FORMS FOR ALLHEDGE PLANTINGS. SPACE EQUALLY(TRIANGULARLY) AS SHOWN.4.INSTALL ALL TREES A MINIMUM OF 3 FEET/1METER FROM BACK OF CURB, EDGE OF WALLOR PAVING.5.FORM MINIMUM 3 INCH/75 MILLIMETERWATERING BASIN AROUND ALL TREES NOTINSTALLED PAVED AREAS. FILL TREE RING WITHA 3 INCH/75 MILLIMETER LAYER OF MULCH.6.NO MULCH OR SOIL TO BE LEFT DIRECTLY ONROOT CROWN.7.REMOVE ALL GIRDLING ROOTS FROM NEW TREEMATERIAL.8.REMOVE TOP AND SIDES OF B&B TREES BURLAPAND WIRE FRAMES, REMOVE ANY EXCESS SOILFROM AROUND ROOT CROWNS.9.FOR BOXED TREES, REMOVE FOUR VERTICALSIDES OF BOX, LEAVING BOTTOM OF BOXINTACT IN TREE PIT.10.FOR BARE-ROOT OR MISSOURI GRAVEL TREES,FOLLOW CLIMATE CONTROLRECOMMENDATIONS OF SUPPLIER, SOAKHYDROGEL SPRAYED ROOTS FOR ONE HOURBEFORE PLANTING. SEE ROOT CROWN 1/2 INCH/13 MILLIMETERS ABOVE ADJACENT SOIL, ANDEVENLY SPREAD OUT ROOTS AND BACKFILL OFSOIL TO AVOID GROUPING OF ROOTS OR FINEROOTS, BUT RATHER RADIALLY ARRANGINGROOTS WITHIN TREE PIT.11.GENTLY LOOSEN OR CUTAWAY PLASTICCONTAINERS FROM CONTAINER STOCKPLANTINGS. FOR HIGHLY ROOT-BOUNDCONTAINERS, SHAVING ROOTS CUTTING FINEROOTS FOR THE OUTER 1/4 INCH/7MILLIMETER OF CONTAINER, FOR MILDLYROOT-BOUND CONTAINERS, HAND LOOSENBEFORE PLANTING.12.EACH LOCATION OF TREE SHALL BE STAKED ATAPPROXIMATE FINISH ELEVATION BYCONTRACTOR FOR REVIEW BY LANDSCAPEARCHITECT AND APPROVAL PRIOR TO FINALINSTALLATION. ALL TREES IN AREA SHALL BESTAKED FOR REFERENCE AND LIMITS OF PLANTBEDS AND PAVING CLEARLY MARKED AT AMINIMUM.13.PLANT NAMES ARE ABBREVIATED ON THEDRAWINGS. SEE PLANT LEGEND FOR KEY ANDCLASSIFICATION.14.ALL TREES TO HAVE A 3 INCH/75 MILLIMETERTHICK LAYER OF MULCH, AND SHRUB ORHERBACEOUS PLANTING AREAS TO RECEIVE 2INCH/50 MILLIMETER THICK LAYER OF MULCH,SEE SPECIFICATIONS.15.DO NOT PLANT GROUND COVERS, HEDGES, ORFLOWERING PLANTS WITHIN 3 FEET/1 METEROF ANY EXISTING AND/OR PROPOSEDHYDRANTS, PIV, FDC, DCDA, ETC.16.SEE SPECIFICATIONS FOR ANCHOR, TREECOLLARS, AND ADDITIONAL PRODUCTS ANDREQUIREMENTS NEEDED FOR PLANTING.TREE PRUNING NOTES:1.ALL EXISTING TREES TO REMAIN WITHIN THELANDSCAPE LIMIT OF WORK TO BE REVIEWEDBY A REGISTERED ARBORIST FOR HEALTH ANDSAFETY. THE ARBORIST WILL MAKERECOMMENDATIONS FOR PRUNING ANDREMOVING AS NECESSARY TO SUPPORT LONGTERM HEALTH AND SAFETY.2.A TREE PRUNING WORK PLAN WILL BESUBMITTED TO THE LANDSCAPE ARCHITECTFOR REVIEW. THIS WORK PLAN WILL BEDEVELOPED BY A REGISTERED ARBORIST, ANDWILL DESCRIBE THE SCOPE OF WORK TO BEUNDERTAKEN.3.ALL DEADWOOD, CROSSING BRANCHES, ANDSTRUCTURALLY COMPROMISED BRANCHES ANDTRUNKS SHALL BE REMOVED. ALL SUCKERS TOBE REMOVED. ALL DENSE CANOPIES INEXISTING TREES TO BE LIFTED ABOVE 8FEET/2.5 METER HIGH FOR TREES 6 INCH/150MILLIMETER DBH OR LARGER.4.ALL PRUNING TO BE DONE BY REGISTEREDARBORIST, FOLLOWING ISA BEST PRACTICESFOR BOTH SAFETY AND METHODS, ANSI 300.5.REMOVE OR CUT AT THE BASE ANY POSTS,FENCING OR OTHER MATERIALS THAT THETREE HAS GROWN AROUND. NOTIFYLANDSCAPE ARCHITECT IF ANY FOREIGNOBJECT REMOVAL REQUIRES ADDITIONALDEMOLITION OF EXISTING TO REMAIN SITESTRUCTURES.PLANTING PLANL5-01LEGENDLIMIT OF WORK (LOW)MUNICIPAL BOUNDARYPlot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L5-01_PLANTING PLAN.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20' NUP: LOW MOW NATIVE UPLAND SPECIES MIXCOMMONNAMECOMP. %BOTANICAL NAMECOMMON NAMENOTESAT3%Asclepias tuberosaButterfly MilkweedFlowering PerennialAL2%Aster lateriflorusCalico AsterFlowering PerennialBC10%Bouteloua curtipendulaSideoats GrammaNative GrassCL3%Coreopsis lanceolataLanceleaf CoreopsisFlowering PerennialEV15%Elymus virginicusVirginia WildryeNative GrassHH3%Heliopsis helianthoidesWoodland SunflowerFlowering PerennialPT8%Pycanthemum tenuifoliumNarrowleaf MountainmintFlowering PerennialRH3%Rudbeckia hirtaBlack-eyed SusanFlowering PerennialSS60%Schizachyrium scopariumLittle BluestemNative GrassSN2%Solidago nemoralisGray GoldenrodFlowering PerennialSYMBOLCODEBOTANICAL NAMECOMMON NAMESIZECONTAINERQTYREMARKSTREESAOACER RUBRUM 'REDPOINTE'REDPOINTE RED MAPLE2.5" CAL.B&B11AGAMELANCHIER X GRANDIFLORA 'AUTUMN BRILLIANCE'AUTUMN BRILLIANCE APPLE SERVICEBERRY8-10` HEIGHTB&B14CLUMP, SPECIMENBOBETULA PAPYRIFERA `OENCI`RENAISSANCE OASIS® PAPER BIRCH8-10` HEIGHTAS INDICATED18CNCERCIS CANADENSIS `NORTHERN STRAIN`NORTHERN STRAIN EASTERN REDBUD8-10` HEIGHTB&B10MULTI-STEM SPECIMENUPULMUS AMERICANA `PRINCETON`PRINCETON AMERICAN ELM2.5" CAL.B&B7SHRUBSAAARONIA ARBUTIFOLIA 'BRILLIANTISSIMA'BRILLIANT RED CHOKEBERRY#3POT10ALARONIA MELANOCARPA `UCONNAM165`LOW SCAPE MOUND® BLACK CHOKEBERRY#2POT63CSCORNUS SERICEA `ARCTIC FIRE`RED TWIG DOGWOOD#2POT92ISILEX GLABRA 'SHAMROCK'SHAMROCK INKBERRY HOLLY#2POT12IRILEX VERTICILLATA `RED SPRITE`RED SPRITE WINTERBERRY#7POT7IV2ILEX VERTICILLATA 'JIM DANDY'JIM DANDY WINTERBERRY#7POT1IMITEA VIRGINICA 'MERLOT'MERLOT SWEETSPIRE#2POT11MDMICROBIOTA DECUSSATASIBERIAN CARPET CYPRESS#3POT81MBMYRICA PENSYLVANICA 'BOBZAM'BOBEE™ NORTHERN BAYBERRY#7POT20SKSYRINGA PUBESCENS PATULA `MISS KIM`MISS KIM KOREAN LILAC#5POT64VDVIBURNUM X RHYTIDOPHYLLOIDES 'DARTS DUKE'DARTS DUKE LANTANAPHYLLUM VIBURNUM#5POT9PERENNIALSPAPOLYSTICHUM ACROSTICHOIDESCHRISTMAS FERN#1POT75SYMBOLCODEBOTANICAL NAMECOMMON NAMESIZECONTAINERSPACINGQTYREMARKSGROUND COVERSBMBIORETENTION MIXSTORMWATER MGMT PLANTS#1POT24" o.c.574JUNCUS EFFUSUS 25%, PANICUM VIRGATUM 'CAPEBREEZE' 30%, IRIS VERSICOLOR 25%, LOBELIACARDINALIS 20%CPCAREX PENSYLVANICAPENNSYLVANIA SEDGEPLUG10" o.c.3,022FMFOREBAY MIXSTORMWATER MGMT PLANTS#1POT24" o.c.569JUNCUS EFFUSUS 30%, CAREX FLACCA 'BLUE ZINGER'25%, ASTILBE JAPONICA 'DEUTCHLAND' 20%,CHELONE GLABRA 25%NUPLOW-MOW NATIVE UPLAND PLUGSNATIVE GRASS FLOWER MIX---PLUG12" o.c.12,43380% NATIVE GRASSES, 20% WILDFLOWERSTSTURFTYPE 1- CORNELL TURFGRASS SEED BLENDSEED35,604 SFTLTURF SEED LOW GROW MIXTYPE 2- LOW-GROW MIXSEED2,541 SFPLANT SCHEDULENFGNARCISSUS 'FEBRUARY GOLD'YELLOW DAFFODILTOPSIZEBULBRANDOM300HAND BROADCASTVT-09VT-07VT-08VT-01VT-02VT-03VT-05PLANTING SCHEDULEL5-02Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L5-02_PLANTING SCHEDULE.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20' LIMIT OF WORKLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKTOWN OF ITHACACITY OF ITHACAMUNICIPAL BOUNDARY0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.00.00.00.00.00.00.00.10.10.10.10.10.00.00.00.00.00.10.10.20.10.10.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.10.20.20.30.10.10.10.10.10.10.10.30.50.30.20.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.10.00.00.00.00.00.00.10.10.10.00.00.00.00.00.00.10.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.10.10.20.41.21.11.30.40.20.20.10.20.40.51.11.50.70.40.20.20.40.30.40.20.20.20.20.20.20.40.30.40.20.20.20.20.10.10.00.00.00.00.00.10.10.10.10.00.00.00.10.10.10.10.20.20.10.10.10.10.10.10.10.20.10.20.10.10.10.10.10.10.10.10.20.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.20.51.11.53.12.33.11.71.20.60.40.50.81.52.32.51.20.80.90.91.10.91.10.90.90.50.60.90.91.20.81.11.01.00.70.50.40.10.10.10.00.00.00.00.00.00.10.20.20.20.10.00.00.00.00.10.20.30.30.40.50.50.50.30.30.30.30.30.30.50.40.50.30.30.30.30.30.30.40.40.50.30.20.30.20.20.30.20.30.40.30.30.20.20.20.30.40.50.81.92.22.51.02.42.12.20.90.61.21.52.63.21.70.61.02.12.42.71.62.92.21.60.70.71.72.12.91.32.82.32.11.11.01.10.40.20.10.10.10.10.10.10.10.10.40.70.80.30.10.00.00.00.10.10.30.91.41.51.31.31.61.41.10.60.71.31.31.41.11.51.21.30.70.61.01.21.41.11.31.31.20.80.40.40.91.11.01.10.90.80.70.90.80.91.01.11.31.91.91.81.21.61.51.71.11.42.73.30.82.81.30.50.92.02.63.51.53.62.21.40.60.61.52.13.61.33.52.41.91.21.92.21.20.70.30.20.10.20.10.10.10.20.51.82.20.60.20.10.00.00.10.10.41.12.32.32.51.52.42.31.40.60.82.02.12.50.92.52.11.90.80.61.52.22.61.32.72.32.21.00.40.51.32.22.82.42.22.42.22.22.52.62.22.32.72.41.40.90.60.80.70.91.83.24.24.02.91.30.60.20.20.40.71.81.41.50.50.30.20.20.30.51.51.41.70.60.40.41.52.42.61.20.70.50.30.50.40.50.30.30.72.02.51.10.30.10.00.00.10.10.30.71.42.32.92.92.71.40.80.40.61.21.73.22.43.21.71.20.50.51.11.63.12.93.22.31.50.70.30.41.01.83.51.93.53.13.02.52.83.42.73.03.32.51.30.50.40.51.01.32.63.34.11.70.90.50.20.10.10.10.20.40.40.40.20.10.10.10.10.20.40.30.40.20.20.20.83.30.92.31.81.41.11.21.01.21.01.21.32.32.62.50.80.10.00.00.00.00.10.20.30.40.71.31.20.80.30.20.10.10.20.41.31.21.30.40.20.10.10.20.31.01.21.40.60.30.20.10.10.20.41.51.73.02.41.81.10.81.52.02.01.40.60.40.30.51.12.12.90.83.71.30.50.20.20.10.10.00.10.10.10.10.10.10.00.00.00.00.10.10.10.10.10.10.20.71.63.02.62.92.92.42.91.12.92.22.01.21.70.81.80.70.10.10.00.00.10.40.70.70.40.30.30.20.10.10.10.10.10.10.30.20.30.10.10.10.10.10.10.20.30.30.20.10.10.10.10.10.20.50.72.22.51.40.40.30.40.60.60.40.20.20.30.81.82.33.60.00.20.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.20.71.82.23.03.12.73.71.53.62.11.71.32.43.02.30.70.10.00.00.00.00.10.61.82.10.50.20.10.10.10.00.00.00.00.10.10.10.10.10.00.00.00.00.00.10.10.10.10.00.00.00.00.10.10.30.82.62.41.40.40.20.20.10.10.10.10.10.20.51.21.30.00.00.00.00.10.10.20.30.51.21.00.81.71.51.60.50.40.62.02.40.90.30.10.00.00.10.20.62.12.50.80.20.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.31.43.12.81.30.50.20.00.10.61.61.90.50.10.10.00.00.10.30.92.43.52.10.60.10.00.00.00.10.31.33.01.91.20.50.10.00.10.40.70.70.30.10.00.00.00.10.30.81.80.11.90.50.10.00.00.10.20.93.02.61.40.40.10.10.40.60.60.30.10.00.00.00.10.30.92.43.52.10.60.10.00.00.10.10.31.62.21.20.30.10.10.51.41.60.50.10.10.00.00.10.20.62.12.50.80.20.10.00.00.00.10.21.01.41.00.30.10.10.51.92.40.80.20.10.00.00.10.10.71.82.10.40.10.10.00.00.10.10.50.60.60.30.10.20.72.33.12.00.60.10.00.00.10.20.50.70.80.30.10.00.00.00.10.10.60.80.70.30.10.20.71.70.92.10.70.10.00.00.10.20.40.60.60.20.10.00.00.00.10.21.22.01.30.30.10.30.82.12.72.30.80.10.00.00.10.20.61.31.40.40.10.00.00.00.10.10.41.72.11.30.30.10.20.62.12.71.20.30.10.00.00.10.10.62.12.50.60.20.10.00.00.10.31.33.22.41.50.60.20.10.62.02.40.60.20.10.00.00.10.20.82.53.31.60.40.10.00.00.10.21.12.60.91.10.40.10.10.51.01.00.40.10.00.00.00.10.30.82.01.52.00.60.10.00.00.10.31.23.22.41.50.60.20.10.40.60.60.30.10.00.00.10.30.92.23.12.10.60.10.00.00.10.10.41.62.11.30.30.10.10.51.01.10.50.10.00.00.00.10.20.72.43.01.30.30.10.00.00.00.10.21.12.01.30.30.10.10.51.92.40.80.20.10.00.00.10.10.62.12.40.60.20.10.00.00.10.10.50.80.70.30.10.20.62.02.61.40.40.10.00.00.10.20.61.11.20.30.10.00.00.00.10.10.40.60.60.30.10.30.81.92.32.40.80.20.00.00.10.20.40.60.50.30.10.00.00.10.20.71.51.20.40.10.20.71.70.92.20.70.10.00.00.10.20.50.91.00.30.10.00.00.00.00.10.31.12.31.60.40.10.20.72.22.92.10.60.10.00.00.10.10.62.02.30.60.20.10.00.00.10.20.72.52.41.90.60.20.10.51.92.40.80.20.10.00.00.10.20.62.12.61.00.30.10.00.00.10.20.92.60.91.40.60.20.10.51.41.60.50.10.10.00.00.10.30.92.23.12.30.70.10.00.00.10.21.12.72.11.60.70.20.10.40.60.60.30.10.00.00.00.10.20.71.70.81.70.60.10.00.00.00.10.51.82.31.70.40.10.10.40.70.80.40.10.00.00.00.10.30.82.43.42.00.60.10.00.00.10.21.02.41.70.40.10.10.41.62.00.70.20.10.00.00.10.10.62.02.40.70.20.10.00.00.10.10.61.11.00.40.10.10.41.72.31.10.30.10.00.00.10.10.61.51.70.50.10.10.00.00.00.10.40.60.60.30.10.20.72.02.42.60.90.20.00.00.00.10.20.40.70.70.30.10.00.00.00.10.10.51.11.00.40.10.20.61.50.72.30.80.20.10.00.00.10.20.40.70.70.30.10.00.00.00.10.20.92.41.70.40.10.20.72.02.42.60.90.20.00.00.00.10.10.61.61.80.50.10.10.00.00.00.10.51.72.41.80.50.10.10.41.82.31.10.30.10.00.00.10.10.52.02.40.80.20.10.00.00.10.21.02.72.21.70.80.40.40.61.91.72.00.70.40.20.20.20.30.61.51.81.91.00.40.20.10.10.00.00.00.00.00.00.00.00.10.10.20.40.81.82.42.41.80.80.50.20.10.10.10.10.10.51.72.10.70.20.10.00.00.10.30.82.33.22.20.60.10.00.00.10.20.92.60.91.50.80.81.92.43.70.33.62.52.10.80.40.61.52.43.61.73.53.02.21.00.30.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.41.32.52.71.61.82.72.51.20.40.20.10.10.10.20.40.70.70.30.10.10.00.00.10.20.71.60.71.70.60.10.00.00.10.20.72.42.52.00.80.81.82.22.71.62.62.32.01.00.60.81.62.32.92.32.52.52.21.00.40.20.10.20.20.20.20.20.20.20.40.30.40.20.20.30.41.11.92.11.71.72.11.91.10.40.30.20.20.40.40.50.40.30.20.10.10.00.00.10.30.92.22.92.30.70.10.00.00.00.10.31.12.41.70.50.50.80.81.00.91.31.41.51.41.21.41.51.41.51.11.10.90.80.70.40.40.40.70.70.30.30.51.01.01.20.91.10.90.90.60.40.50.50.60.70.70.60.50.50.50.70.90.91.10.91.10.80.70.40.20.10.00.00.10.20.62.02.51.00.30.10.00.00.10.20.71.61.30.50.20.20.20.40.40.81.52.32.92.32.62.72.31.30.60.50.30.30.50.61.01.52.11.50.60.30.61.72.12.91.12.82.22.00.80.30.20.10.20.20.20.20.10.20.31.02.12.42.62.02.82.21.50.50.20.10.00.00.10.10.61.92.30.60.20.10.00.00.10.10.40.60.60.40.20.10.10.20.20.51.42.43.61.93.53.12.31.10.40.30.30.40.81.41.62.82.41.70.50.20.51.31.93.51.43.52.31.80.70.20.10.10.10.10.10.10.10.10.30.82.02.83.51.43.72.41.60.50.20.10.00.00.10.50.80.90.30.10.00.00.00.10.10.40.80.70.40.10.10.10.10.10.20.30.51.51.81.91.10.50.30.30.30.61.32.02.90.93.41.90.50.20.10.10.20.41.51.41.70.60.30.20.10.10.00.00.00.00.00.00.10.10.20.40.91.81.71.60.70.50.30.10.10.00.00.10.40.50.50.30.10.00.00.10.20.62.01.60.50.10.10.00.00.10.10.10.20.40.50.60.40.30.30.40.50.71.42.52.92.71.41.00.20.10.10.10.10.20.30.30.40.20.10.10.00.00.00.00.00.00.10.10.30.50.50.60.80.80.50.10.10.00.00.10.40.91.00.50.10.10.00.00.10.31.02.31.80.50.10.10.00.00.00.00.10.10.10.20.30.40.70.71.41.00.60.80.90.61.00.50.30.10.10.00.00.00.10.10.10.10.10.00.00.00.00.00.10.10.10.20.41.52.01.00.20.10.00.00.00.10.41.82.40.80.20.10.00.00.00.20.82.52.62.10.80.30.10.00.00.00.00.10.10.10.20.60.81.32.32.21.60.50.30.20.20.20.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.41.52.21.40.40.10.00.00.00.10.10.51.82.41.60.40.10.00.00.00.10.20.72.20.71.50.60.20.10.10.10.10.10.10.20.40.71.42.21.12.72.20.80.20.10.10.10.10.00.00.00.00.10.20.61.72.22.91.10.20.10.00.00.10.20.71.72.22.71.00.20.10.00.00.10.20.92.52.42.00.80.30.10.10.10.10.10.30.50.91.92.12.72.02.61.10.30.10.10.00.00.00.00.00.10.20.51.30.92.71.00.20.10.00.00.10.20.51.30.92.40.90.20.10.00.00.10.10.31.12.31.80.50.20.10.20.20.40.50.91.20.91.52.11.81.90.90.50.10.10.00.00.00.10.20.71.82.32.91.10.20.10.00.00.10.20.61.92.52.60.80.20.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.20.72.11.70.50.20.10.30.70.91.72.22.01.00.60.40.40.50.20.10.10.00.00.00.10.10.41.62.31.40.40.10.10.00.00.10.10.41.62.31.20.40.20.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.20.20.40.80.70.40.30.40.81.61.72.52.81.70.50.20.10.10.10.10.10.00.00.00.10.61.92.41.10.20.10.00.00.00.10.10.41.41.70.90.50.30.30.20.20.20.20.20.20.40.30.40.20.20.20.20.20.20.30.30.40.30.20.20.20.20.20.30.40.40.50.40.40.40.51.22.12.42.72.92.30.50.20.10.10.00.00.00.00.00.00.10.61.72.11.00.20.10.00.00.10.20.51.01.21.11.00.90.90.70.70.50.60.80.81.00.91.00.80.80.60.50.80.91.11.01.11.00.90.70.50.71.01.01.10.91.21.00.90.60.51.02.32.12.51.41.00.20.10.00.00.00.00.10.10.41.72.51.30.30.10.00.00.00.10.10.41.22.32.62.42.22.72.21.30.60.81.82.22.61.62.72.21.80.80.61.42.22.92.22.62.52.21.10.61.02.12.42.71.72.92.21.50.60.40.50.60.40.60.50.20.10.10.00.00.10.20.61.82.52.60.80.20.10.00.00.10.10.31.12.43.13.41.93.52.41.40.60.71.92.43.60.33.62.41.90.70.61.32.23.52.13.42.82.11.00.50.92.02.63.51.73.62.11.40.50.20.20.10.10.10.10.10.00.00.00.00.10.20.61.40.92.71.00.20.10.00.00.00.10.10.30.51.11.91.81.50.50.30.20.20.40.61.91.71.90.60.40.20.20.30.51.31.61.80.90.40.20.20.20.40.71.71.41.40.50.30.10.10.10.10.10.00.00.00.00.00.10.20.61.52.12.81.10.20.10.00.00.00.10.10.20.30.50.50.40.20.10.10.10.10.20.50.40.50.20.10.10.10.10.20.30.40.40.20.10.10.10.10.10.20.40.40.30.20.10.10.00.00.00.00.00.00.00.10.41.62.31.90.50.10.00.00.00.00.00.10.10.10.10.10.10.00.00.00.00.10.10.10.10.10.00.00.00.00.10.10.10.10.10.10.00.00.00.10.10.10.10.10.10.00.00.00.00.10.31.62.31.10.20.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.30.91.00.50.10.00.00.00.10.20.30.30.20.10.00.00.00.10.10.10.10.00.00.00.00.00.00.00.0F1F2F3F4F1F2F3F45/4/2023 9:55:01 AMSITE LIGHTING PLANL6-01Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L6-01_LIGHTING PLAN.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'SYMBOLDESCRIPTIONLIMIT OF WORK (LOW)MUNICIPAL BOUNDARYLEGENDSPORTS LIGHT POLE, MUSCO'LIGHT-STRUCTURE SYSTEM'F1-F2: 70' MOUNTING HEIGHTF3-F4: 80' MOUNTING HEIGHTSITE LIGHT POLE,BEGA POLE-TOP LUMINAIRE,14' MOUNTING HEIGHT11.8ILLUMINATION LEVEL(FOOTCANDLE)1" = 30' LIMIT OF WORKLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKTOWN OF ITHACACITY OF ITHACAMUNICIPAL BOUNDARYF1F2F3F40.00.00.00.00.00.00.00.00.00.00.10.10.10.10.10.10.00.00.00.00.00.10.20.30.30.30.30.20.10.10.10.00.00.00.00.20.50.81.01.11.10.80.80.50.20.10.00.00.00.10.71.72.63.85.04.84.54.32.70.80.20.10.00.00.52.66.310.116.018.315.815.517.811.42.00.50.10.00.00.01.711.329.134.241.640.035.636.742.029.75.30.90.20.00.00.00.12.417.649.253.051.652.149.151.256.445.08.21.00.20.00.00.00.10.73.813.938.449.648.149.949.852.452.436.19.10.80.00.00.00.00.10.31.34.314.340.753.853.149.050.153.453.644.611.81.10.10.00.00.10.20.61.54.615.540.255.054.450.951.856.657.645.712.82.00.30.10.00.00.10.20.61.65.015.936.553.752.449.049.054.456.843.112.42.40.50.10.00.00.10.20.61.75.015.334.952.152.247.149.053.956.042.311.42.10.50.20.00.00.10.20.61.65.015.936.453.652.348.849.054.457.042.912.22.40.50.10.00.00.10.20.61.54.715.639.955.054.350.951.756.557.545.712.92.10.30.10.00.00.00.10.31.44.414.341.054.153.449.250.453.853.844.311.81.20.10.00.00.00.00.10.73.813.838.550.048.149.649.652.152.536.79.40.80.00.00.00.00.22.517.448.552.951.652.449.450.956.144.88.20.90.20.00.00.01.812.030.935.943.141.136.737.843.530.85.50.90.20.00.00.62.86.810.817.119.316.716.419.012.22.10.50.10.00.00.10.71.82.84.15.45.24.84.72.90.80.20.10.00.00.00.20.60.91.11.21.20.90.80.50.30.10.00.00.00.10.20.30.40.40.30.20.10.10.10.00.00.00.00.10.10.10.10.10.10.00.00.00.00.00.00.00.00.00.00.00.0F1F2F3F45/4/2023 9:55:01 AMFIELD LIGHTING PLANL6-02Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L6-01_LIGHTING PLAN.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'SYMBOLDESCRIPTIONLIMIT OF WORK (LOW)MUNICIPAL BOUNDARYLEGENDSPORTS LIGHT POLE, MUSCO'LIGHT-STRUCTURE SYSTEM'F1-F2: 70' MOUNTING HEIGHTF3-F4: 80' MOUNTING HEIGHTSITE LIGHT POLE,BEGA POLE-TOP LUMINAIRE,14' MOUNTING HEIGHT11.8ILLUMINATION LEVEL(FOOTCANDLE)1" = 30' B C A UNDISTURBED ORCOMPACTED SUBGRADECOMPACTED DENSEGRADED CRUSHED STONEBITUMINOUS CONCRETEBINDER COURSEAPPLY TACK COATBETWEEN LAYERS12" MIN.ABVEHICULAR1 1/2"2 1/2"C12"BITUMINOUS CONCRETEWEARING (SURFACE)COURSEAPPLY JOINT ADHESIVE TOALL TOP COURSE JOINTSFILTER FABRIC MIRAFI500X OR EQUIVALENT6"GRADED, GRANULAR,FREE-DRAINING CRUSHEDSTONE OR GRAVELAGGREGATE BASE COURSE1'COMPACTED OR UNDISTURBEDSUBGRADEREINFORCING BAR @ 12''O.C., BOTH DIRECTIONS. SEESPECIFICATIONS.3"3"SEE SPECIFICATIONS FORCONCRETE FINISH, TYP.34" DEEP SAWCUT JOINT, TYP.FILTER FABRIC MIRAFI500X OR EQUIVALENT6"6"1'-6"COMPACTED ORUNDISTURBEDSUBGRADEDRAINAGE STONEFILTER FABRIC1 12 " to 2" RIVER STONEPLANTING, TYP.14" THICK X 5" DEEPSTEEL EDGING, STAKED.SEE SPECIFICATIONS.BUILDING FACE, TYP.,SEE ARCH. DWGSDRAINAGE BOARD,SEE ARCH. DWGS6"6" PERFORATED PVCUNDERDRAIN PIPE, SEECIVIL DRAWINGSFILTER FABRICEQ.EQ.6"REINFORCED CAST IN PLACECONCRETE PAVING WITHINTEGRAL COLOR & EXPOSEDSILICA CARBIDE FINISH1'COMPACTED OR UNDISTURBEDSUBGRADE34" DEEP SAWCUT JOINT, TYP.WELDED WIRE FABRICREINFORCEMENT, W2.9xW2.9x6/6.SEE SPECIFICATIONS.GRADED, GRANULAR,FREE-DRAINING CRUSHEDSTONE OR GRAVELAGGREGATE BASE COURSEVARIES12"FLEXIBLE SEALANTBACKER RODCOMPRESSIBLEFILLER12" S.S. SLIP DOWEL, 30" O.C.CORE DRILL INTO EXISTINGCONCRETE, SET DOWEL WITHNON-SHRINK EPOXY.BELOW GRADECONDITION VARIESFINISH VARIES. SEESPECIFICATIONS.10"6"CAST-IN-PLACE REINFORCEDCONCRETE HAUNCH12"EXISTING CONCRETEEQ.EQ.COMPACTED ORUNDISTURBED SUBGRADEAGGREGATE BASE COURSEFILTER FABRICSTABILIZED STONEDUSTPAVINGNOTES1.INSTALLATION TO BECOMPLETED IN ACCORDANCEWITH MANUFACTURERSSPECIFICATIONS.6"3"14" THICK X 5" DEEP STEELEDGING WITH 18" DEEPSTAKEPLANTED AREADECOMPOSED GRANITE OR 38"OR 14" CRUSHED AGGREGATESCREENINGS5"6"COMPACTED OR UNDISTURBEDSUBGRADEGALVANIZED WELDED WIRE FABRICREINFORCEMENT, W2.9xW2.9x6/6.SEE SPECIFICATIONS.21 2"SEE SPECIFICATIONS FORCONCRETE FINISH, TYP.34" DEEP SAWCUT JOINT, TYP.GRADED, GRANULAR,FREE-DRAINING CRUSHEDSTONE OR GRAVELAGGREGATE BASE COURSEFILTER FABRIC MIRAFI500X OR EQUIVALENT8"NOTES1.CONCRETE PAVING SHALL BE LIGHT BROOM FINISH, UNLESS OTHERWISE NOTED.2.SEE SPECIFICATIONS FOR CONCRETE JOINT REQUIREMENTS.COMPACTED ORUNDISTURBEDSUBGRADEPROCESSEDAGGREGATE BASECAST-IN-PLACECONCRETE PAVEMENT,TYP.PLANTED AREA WITH MULCH,TYP. SEE SPECIFICATIONS.8"#4 BARS @ 12" O.C.6"3" MIN.6"1'-6"COMPACTED ORUNDISTURBEDSUBGRADECOMPACTEDAGGREGATEBASEFILTER FABRIC1 12 " to 2" RIVER STONEPLANTING, TYP.14" THICK X 5" DEEPSTEEL EDGING, STAKED.SEE SPECIFICATIONS.BUILDING FACE, TYP.,SEE ARCH. DWGS6"1'VARIES12"FLEXIBLE SEALANTBACKER RODCOMPRESSIBLE FILLER12" S.S. SLIP DOWEL FIXED ATONE END 30" O.C.CAST IN PLACE CONCRETE BASEWITH FIBERMESH REINFORCINGBELOW GRADE CONDITION VARIESFINISH VARIES. SEE SPECIFICATIONS.NOTE:1.REFER TO LAYOUT PLANS FOR JOINTING TYPE, LAYOUT, ANDSPACING, TYP.VARIES12"FLEXIBLE SEALANTBACKER RODCOMPRESSIBLE FILLERADJACENT RIGID ELEMENTVARIES: WALL, CURB, FOOTING,OR OTHER, TYP.FINISH VARIES. SEE SPECIFICATIONS.NOTE:1.REFER TO LAYOUT PLANS FOR JOINTING TYPE, LAYOUT, ANDSPACING, TYP.2.EXPANSION JOINTS SHALL BE INSTALLED BETWEEN RIGIDSURFACES SUCH AS WALLS, CURBS, PAVINGS, AND FOOTINGS.SEE SPECIFICATIONS.NOTE:1.REFER TO LAYOUT PLANS FOR JOINTING TYPE, LAYOUT, ANDSPACING, TYP. SEE SPECIFICATIONS.SAW CUT JOINTJOINT DEPTH = 14 OF DEPTH OF CONCRETE SLAB, TYP.1/8", TYP.Indoor Sports and RecreationSITE DETAILS - PAVINGL8-01ASPHALT PAVINGPA-011" = 1'-0"CONCRETE PAVING - HEAVY-DUTYPA-021" = 1'-0"COLORED CONCRETE PAVING W/ SILICA CARBIDEPA-041" = 1'-0"STABILIZED STONEDUST PAVINGPA-051" = 1'-0"CONCRETE PAVINGPA-031" = 1'-0"SMOOTH CONCRETE PAVER BANDPA-101" = 1'-0"HEAVY-DUTY CONCRETE PAD FOR EXISTING DUMPSTERSPA-091" = 1'-0"RIVERSTONE DRIP EDGEPA-061" = 1'-0"RIVERSTONE DRIP EDGE WITH UNDERDRAINPA-071" = 1'-0"C.I.P CONCRETE AT EXISTING CONCRETE PAVINGPA-081" = 1'-0"DETAIL IN PROGRESS, PENDINGCOORDINATIONPlot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L8-01_SITE DETAILS.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'AS NOTEDEXPANSION JOINTJT-013" = 1'-0"EXPANSION JOINT AT VERTICAL ELEMENTJT-023" = 1'-0"CONTROL JOINTJT-033" = 1'-0" HIGH USE LAWN SOILPREPARED SUBGRADEMEADOW/POVERTY SOILORSTRIPPED EXISTINGTOPSOIL/MEADOW SOIL,SEE SPECIFICATIONS2" DEPTH MULCH.4" FIBER REINFORCED UPPER,SEE SPECIFICATIONS14" THICK X 5" DEEP STEELEDGING, STAKED. SEESPECIFICATIONS.LAWN AREAPLANTING AREAHEAVY-DUTY CONCRETEPAVING WITH CONCRETEHAUNCH3"R 1 "NOTES:1. TOP OF MOUNTABLE CURB ELEVATION TO MATCH LINE AND GRADE OF EXISTING ADJACENTCURBS. SEE MATERIAL AND LAYOUT PLANS FOR ALIGNMENT AND EXTENTS.FLUSH10"1'-6"R1"GRANITE CURB, ALIGN FACESOF CURBSADJACENT EXISTINGASPHALT PAVEMENTEXPANSION JOINT12"10"6"44.4°AGGREGATE BASE COURSE11 2" 1'HEAVY-DUTY CONCRETEPAVING WITH CONCRETEHAUNCHNOTES:1. TOP OF CONCRETE MOUNTABLE CURB ELEVATION TO MATCH LINE AND GRADE OF EXISTINGADJACENT CONCRETE ROAD CURBS. SEE MATERIAL AND LAYOUT PLANS FOR ALIGNMENT ANDEXTENTS.FLUSH1'-6"ADJACENT EXISTINGASPHALT PAVEMENTSALVAGED OR NEW TYPE 'C'GRANITE CURBEXPANSION JOINT12"10"6" 1'AGGREGATE BASE COURSELEGENDNOTESA.REFER TO SPECIFICATION SECTION "321726 -TACTILE WARNING PAVERS" FOR ADDITIONALINFORMATION.1.CAST IRON (UNPAINTED) DETECTABLE WARNINGPAVER, TYP.2.CURB, SEE PLANS FOR MATERIAL3.FLUSH CURB4.PORTLAND CEMENT CONCRETE PAVEMENT, SEE1/L4-005.MORTAR SETTING BEDPLANTINGAREA213PLANSCALE:12" = 1'-0"2'-0" MIN.SECTIONSCALE:3" = 1'-0"1541"SECTIONSCALE:3" = 1'-0"1541"LEGENDNOTESA.REFER TO SPECIFICATION SECTION "321726 -TACTILE WARNING PAVERS" FOR ADDITIONALINFORMATION.1.CAST IRON (UNPAINTED) DETECTABLE WARNINGPAVER, TYP.2.CURB, SEE PLANS FOR MATERIAL3.FLUSH CURB4.PORTLAND CEMENT CONCRETE PAVEMENT, SEE1/L4-005.MORTAR SETTING BED2'-0" MIN.PLANSCALE:12" = 1'-0"STREETPLANTINGAREAPLANTINGAREA13222'-0", TYP.6'-0"6"CAST IRON DETECTABLE WARNINGPLATE, TYP.CAST-IN-PLACE CONCRETECOMPACTED AGGREGATE BASEAT FLUSH CONDITIONSOIL SUBGRADE SHALL BE PREPAREDIN ACCORDANCE WITH THEREQUIREMENTS OF THE EARTHWORKSPECIFICATION AND THEGEOTECHNICAL ENGINEERING STUDY.SET AGAINSTADJACENT SURFACE1'-4" 6"5"6"MIN.6"MIN.9"SALVAGED OR NEW TYPE 'C' GRANITECURB, SAWN TOP,SPLIT FACE, 4' MIN. LENGTH6 MIL POLYETHYLENE BOND BREAKERADJACENT TO CONCRETE3" MIN.CONCRETE FOOTINGCOMPACTED SUBGRADEAGGREGATE BASE COURSENOTE: CAULK JOINTS EVERY 150' AND OTHER JOINTS <18" GAPVARIES, SEE PLAN3'-0" MIN.SLOPESLOPE SLOPEDETECTABLE WARNINGPAVERSVARIESVARIES1:10 MAX1:10 MAX1:12 MAX SITE DETAILS - EDGECONDITIONSL8-02GRANITE MOUNTABLE CURBEG-011" = 1'-0"GRANITE FLUSH CURBEG-021" = 1'-0"CAST IRON FLUSH WARNING PAVEREG-071" = 1'-0"STEEL EDGINGEG-081' = 1'-0"GRANITE CURBEG-031" = 1'-0"TACTILE WARNING PAVERS ON RADIUSEG-041/2" = 1'-0"TACTILE WARNING PAVERSEG-051/2" = 1'-0"DROP CURBEG-066" = 1'-0"Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L8-01_SITE DETAILS.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'AS NOTED 2" DEPTH COMPOSTED BARK MULCH,KEEP FREE OF TRUNKS / STEMSSET CROWN OF ROOTBALL 1"ABOVE FINISHED SOIL GRADEREMOVE ROPES, WIRES, &NON-BIODEGRADABLE MATERIALSFROM ROOTBALL, LOOSEN ROOTBOUND ROOTBALLS OF CONTAINERGROWN SHRUBSLCLCNOTE:1.PRUNE BROKEN BRANCHES.HAND WATER IN ALLSHRUBS AFTER PLANTING.DRAINAGE SAND, SEE CIVIL DRAWINGSFOR DRAINAGE DETAILS AND TYPESPREPARED SUBGRADE1'PLANTING BED SOILHORTICULTURAL SUBSOIL2'VARIESVARIES2" DEPTH LEAF MULCH.DO NOT COVER STEMSOR FOLIAGEREMOVE CONTAINERAND LOOSEN ROOTBALLSPREPARED SUBGRADEDRAINAGE SAND, SEE CIVILDRAWINGS FOR DRAINAGE DETAILSAND TYPES1'1'PLANTING BED SOILHORTICULTURAL SUBSOILFINISHED GRADESODDED LAWNDRAINAGE SAND, SEE CIVILDRAWINGS FOR DRAINAGEDETAILS AND TYPESPREPARED SUBGRADEPLANTING BED SOILHORTICULTURAL SUBSOIL1'1'6060 60`A'`A'`A'`B'PLANT SPACING (`A')6 IN. O.C.8 IN. O.C.10 IN. O.C.12 IN. O.C.15 IN. O.C.18 IN. O.C.24 IN. O.C.30 IN. O.C.26 IN. O.C.21 IN. O.C.16 IN. O.C.13 IN. O.C.10-1/2 IN. O.C.8-1/2 IN. O.C.7 IN. O.C.5 IN. O.C.ROW SPACING (`B')EXTENT OF PLANTING PIT2"-3" DEEP LOAM WATERING BERM @EDGE OF ROOTBALL, REMOVE AFTERONE YEAR3'MULCH RINGPLAN2" DEPTH MULCH, DO NOT APPLYMULCH TO ROOT FLARE OF TREE(3) 2"X4"X10' STAKES DRIVEN MIN24" INTO UNDISTURBED GRADEOUTSIDE ROOTBALL3'MULCH RINGSECTION120°WOOD STAKES SPACED EQUALLYAROUND TREE (3 PER TREE)TREEROOTBALLEXTENT OF MULCH RING.DO NOT APPLY MULCH TOROOT FLARE OF TREE18'-0"GUY WIRE (3 PER TREE)PREPARED SUBGRADE OR STRUCTURE6"ALLSIDESCUT AND REMOVE BURLAP ANDCOMPLETELY REMOVE WIREBASKET ANDNON-BIODEGRADABLE MATERIALSFROM ROOTBALLNOTE:1.SET TREE TRUNK PLUMB VERTICAL.2.MULCH SHALL NOT COVER BASE OF TREE TRUNK.3.PRUNE BROKEN, CROSSING OR RUBBING BRANCHES.4.REFER TO SPECIFICATIONS FOR STAKING INFORMATION.COMPACTEDHORTICULTURAL SUBSOILSET TREE FLARE AT FINISHEDGRADE OF SOILTREE WATERING STAKES, SEEIRRIGATION DRAWINGS1'2'DEPENDS ON ROOTBALL SIZE, TYP.PLANTING BED SOILHOSEARBORTIE, FIXED TO WOOD POSTHORTICULTURAL SUBSOIL, DEPTHDEPENDS ON ROOTBALL SIZE, TYP.CUT AND REMOVE BURLAPAND COMPLETELY REMOVEWIRE BASKET3' DIA. MULCH (NO MULCHAROUND TRUNK BASE)CONTRACTOR SHALL REMOVEEXCESS FILL FROM TOP OFTRUNK. SET CROWN OF ROOTBALL 2" HIGHER THANFINISHED GRADE.TREES ARE TO BE PRUNED TOMAINTAIN UNDERSTORY.COMPACTED SOIL PEDESTALTO PREVENT SETTLING WITHTREES > 2.5" CALIPER TRUNKSCARIFY SIDES AND BOTTOMOF HOLEROOTBALL3' DIA. MULCH (NO MULCHAROUND TRUNK BASE)VARIES, SEE PLANSNO GROUNDCOVEROVER ROOT BALLNOTE:1.TREE TRUNK TO BE PLUMB VERTICAL.2.MULCH SHALL NOT COVER BASE OF TREE TRUNK OR GROUND COVER.3.ALL TREES TO BE STAKED PER TREE STAKING DETAIL.PLANSECTIONPREPARED SUBGRADE ORSTRUCTUREPLANTING BED SOILARBORTIE, FIXED TO WOOD POSTWOOD STAKES (3 PER TREE)SP-04PLANTING SOIL, SEE PLANSPREPARED SUBGRADE ORSTRUCTUREARBORTIE, FIXED TO WOOD POSTROOTBALLSOIL SAUCER120°2" DEPTH MULCH, DO NOT APPLYMULCH TO ROOT FLARE OF TREETREEARBORTIE GUY (3 PER TREE)PLANEXTENT OF PLANTING PIT5'-1114"ALLSIDESPLANT PIT=3X ROOT BALL DIAMETERSECTIONCUT AND REMOVE BURLAPAND COMPLETELY REMOVEWIRE BASKET ANDNON-BIODEGRADABLEMATERIALS FROM ROOTBALLWOOD STAKES (3 PER TREE)WOOD STAKES(3 PER TREE)NOTE:1.SET TREE TRUNK PLUMB VERTICAL.2.MULCH SHALL NOT COVER BASE OF TREE TRUNK.3.FOLLOW MANUFACTURER INSTRUCTIONS FOR ARBORTIE INSTALLATION.4.PRUNE BROKEN, CROSSING OR RUBBING BRANCHES.5.REFER TO SPECIFICATIONS FOR STAKING INFORMATION.PLANTING BED SOIL1'HORTICULTURAL SUBSOIL, DEPTHDEPENDS ON ROOTBALL SIZE, TYP.MEADOW SOILNO-MOW FESCUE ANDPERENNIALS; SEEPLANTING PLAN1'-0"SCARIFY SUBGRADEPREPARED SUBGRADE;SEE SPECIFICATIONSPERFORATED PIPE WITHFILTER FABRIC SOCK (ASREQUIRED)SAND DRAINAGELAYER (ASREQUIRED)4"-6"PLACE MIN 2" MULCH OVERSLOPE, TAKING CARE NOT TOBURY PLANTSPLANT SHRUBS AND LARGERPLANTS AT SLOPE ANGLE,ROUGHEN ROOTBALLS TOIMPROVE CONTACT W/ SOIL.REFER TO CIVIL DRAWINGS FORSLOPE REINFORCEMENT FORSLOPES GREATER THAN 3:1PLANTING SOILPLACE & COMPACT FILL IN 6"LIFTS, CREATING BENCHES TOSTABILIZE PLANTING BED SOIL4'NOTES:1.SET TREE TRUNK PLUMB VERTICAL.2.MULCH SHALL NOT COVER BASE OF TREE TRUNK.3.PRUNE BROKEN, CROSSING OR RUBBING BRANCHES.4.REFER TO SPECIFICATIONS FOR STAKING INFORMATION.3'-0"PREPARED SUBGRADETREE WATERING STAKES, SEEIRRIGATION DRAWINGSPLANTING SOIL (AS NEEDED); DONOT BURY THE TREE FLARE. SETFLARE OF TREE AT TOP OF SANDBASED STRUCTURAL SOILTREE GRATECUT AND REMOVE TOP ALL BURLAP ANDCOMPLETELY REMOVE WIRE BASKET ANDNON-BIODEGRADABLE MATERIALS FROMROOTBALLCOMPACTEDHORTICULTURAL SUBSOIL212"1'2"MIN.CU STRUCTURAL SOILPRECAST CONCRETE PAVERSDRAINAGE SANDWASHED AASHTO #57 STONE6"6"SITE DETAILS - PLANTINGL8-03SHRUB AND GROUNDCOVER PLANTINGVT-011" = 1'-0"SHRUB AND GROUNDCOVER PLANTING - ON SLOPEVT-021" = 1'-0"PERENIAL AND GROUNDCOVER PLANTINGVT-031" = 1'-0"SHRUB AND GROUNDCOVER TRIANGULATION LAYOUTVT-041" = 1'-0"SODDED LAWNVT-051" = 1'-0"MEADOWVT-061' = 1'-0"DECIDUOUS TREE PLANTINGVT-071/2" = 1'-0"MULTI STEM TREE PLANTINGVT-081/2" = 1'-0"CONFIER TREE PLANTINGVT-091/2" = 1'-0"PROPOSED DECIDUOUS TREE AT CONCRETE PAVEMENTVT-101/2" = 1'-0"Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L8-01_SITE DETAILS.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'AS NOTED NOTES1.BIKE RACK 'DOWNTOWN' BY DERO2.TO BE INSTALLED PLUMB VERTICAL3.FOLLOW MANUFACTURER RECOMMENDATION FOR SPACING2'-6"2'-8" 10"PLANSECTIONCORE DRILLEDCONCRETE FOOTING2 38"AA1SECTION A-A1POLE BASE DIMS VARYREFER TO PLANS1"LIGHT POLEBASE PLATECOVERANCHOR BOLTSREINFORCEDCONCRETEFOUNDATION,(REFER TO GSSERIES DRAWINGS)ELECTRICALCONDUITUNDISTURBED ORCOMPACTEDSUBGRADECAST-IN-PLACECONCRETE CAP.BONDING AGENTSHALL BE APPLIEDTO CONCRETEFOUNDATION PRIORTO INSTALLATIONOF "CAP" POUR.PREPARE EXPOSEDANCHOR BOLTS TOPROMOTEBONDING WITHCONCRETE CAP6x6 W2.0 xW2.0 REINF.CLAMPGROUND CABLESURFACEVARIES, SEEPLANSNOTES1.CONTRACTOR SHALL USE CAMPUSSTANDARD BLUE LIGHT PHONE MODEL ANDMANUFACTURER. SEE CAMPUS STANDARDSPECIFICATIONS.2.REFER TO MANUFACTURER SPECIFICATIONSFOR INSTALLATION INSTRUCTIONS.4'-0"1'-6"(4) 5#VERTICAL(3) #4 STIRRUPS@ANCHOR BOLTLOCATION, @3O.C.(2) #4STIRRUPS @12"O.C.#3 TIES @8"O.C.(4) 34" DIA X 26"HOT DIPGALVANIZEDVARIES, SEEMATERIALS PLANPLANELEVATIONSECTION6'SITE DETAILS - FURNISHINGSL8-04BIKE RACK ANCHORSF-011" = 1'-0"LIGHT POLE FOUNDATION - IN PLANTINGSF-021" = 1'-0"BLUE LIGHT PHONESF-031/2" = 1'-0"PRECAST CONCRETE BENCHSW-01N.T.S.Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L8-01_SITE DETAILS.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'AS NOTED 11.SYNTHETIC TURF FIBER WITH RUBBER/SAND INFILL2.PERFORMANCE SHOCK PAD3.TOP DRAINAGE STONE: 1"4.DYNAMIC BASE DRAINAGE STONE: 10.5" - 12"DEPTH (SEE GRADING PLANS)5.PANEL DRAIN6.GEOTEXTILE FABRICA.FG: FINISHED GRADE (TOP OF TOP FIBER)B.TEL: TOP OF E-LAYERC.TOS: TOP OF DRAINAGE STONED.TSG: TOP OF SUBGRADEE.SEE PLANS AND SPECIFICATIONS FOR SYNTHETICTURF FIELD SYSTEM.LEGENDNOTES34562UNDISTURBED SUBGRADECOMPACTED AGGREGATE6"HDPE OUTLETGRAVEL BEDDINGADS DRAINAGE BASINSQUARE CAST IRON GRATEH-10 LOADING. ADACOMPLIANTSEE DRAINAGE PLAN 12" SUMP 6"DIAMETER NOTED IN PLANRESTRICTOR PLATEWHERE REQUIRED1LEGEND1.PUBLIC ADDRESS & SCOREBOARD SECTION2.SYNTHETIC TURF SYSTEM3.SET E-LAYER FLUSH WITH CONCRETE CASING4.REMOVABLE ALUMINUM COVER WITH SYNTHETIC TURFSYSTEM PANEL, SET FLUSH TO TOP OF TURF5.SPORTSFIELD SPECIALTIES COMBOX 3500 (30" X 18")6.OPEN BOTTOM DRAIN TO STONE7.CAST-IN-PLACE CONCRETE ENCASEMENT8.DRAINAGE PIPE OVERFLOW TO STONE234671'-212"111 4"61 2"1'-212"2'NOTESA.INSTALL BOX PER MANUFACTURER'S SPECIFICATIONS.B.PROVIDE ALL CONDUIT AND ELEC/COMM BOXES PERAUDIOVISUAL PLANS.C.WHERE BOTH ELECTRICAL AND COMMUNICATION ORDATA SHARE A BOX, INSTALL CODE COMPLIANTSEPARATION BARRIER BETWEEN SYSTEM TYPES.D.BOXES SHALL BE INSTALLED FLUSH WITH TOP OF TURF.E.BOTTOM OF BOXES TO HAVE 2" WASHED STONE BASE.IN CASES WHERE BOXES ARE WITHIN TEN FEET OFDRAIN OR NOT WITHIN WELL-DRAINED SUBSTRATE,PROVIDE CONCRETE BOTTOM AND PIPE CONNECTIONTO DRAIN.F.ALL CONDUITS SHALL EXTEND 4" ABOVE TOP OFWASHED STONE BASE MATERIAL.G.ALL CABLES AND CONDUCTORS SHALL BE FULLYPROTECTED WITH RIGID CONDUIT OR FLEX-TIGHTCONDUIT.954910711.JUNCTION BOX1.1.NEMA TYPE 3R, WALLMOUNTED HINGE COVER BOX(8"D X 14"W X 16"H)1.2.14GA GALVANIZED STEEL,BLACK1.3.HINGED GASKETED DOOR1.4.GASKETED HINGED ACCESSCOVER AT BOTTOM FOR CABLEPASS THROUGH1.5.WALL MOUNTED FEET.2.UNISTRUT3.CONCRETE TURF CURBNOTES:1.MOUNT JUNCTION BOX TOUNISTRUT.2.CONDUITS TO RUN FROM HANDHOLE TO JUNCTION BOX.3.EACH LOCATION TO INCLUDEDOUBLE DUPLEX OUTLET ANDACCOMMODATIONS FOR OITLEGEND24FIELD DETAILSL8-10Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L8-10_FIELD DETAILS.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'AS NOTEDSYNTHETIC TURF SYSTEMFD-013' = 1'-0"AREA DRAIN AT SYNTHETIC LANDSCAPE TURFFD-041' = 1'-0"ELECTRICAL & COMMUNICATIONS BOXFD-051' = 1'-0"JUNCTION BOX AT FENCEFD-061' = 1'-0"SCOREBOARDFD-076" = 1'-0"DRAIN CLEANOUT - SYNTHETIC TURF FIELDFD-031' = 1'-0"14"2.00' (24")1.2"W x 1"W CONCRETE NOTCH2.SYNTHETIC TURF3.DRAINAGE STONE4.GEOTEXTILE FABRIC5.SYNTHETIC TURF PERIMETER CONCRETE CURB6.4 #4 BAR HORIZONAL CONTINUOUS REINFORCING; 8" LAP7.#4 TIE @ 8' ON CENTER8.6"D COMPACTED AGGREGATE BASE9.COMPACTED SUBGRADE10.ADJACENT SURFACE, VARIESLEGEND8567129A.NOTCH IN CONCRETE: 1"D X 2"WB.TOP OF CONCRETE NOTECH ELEVATIONSHOULD BE SET BASED ON SYNTHETIC TURFINFILL DEPTHC.TOP OF STONE TO BE FLUSH WITH TOP OFCONCRETE NOTCH. 1" BELOW FINISHEDGRADE.D.TOP OF INFILL LAYER TO BE FLUSH WITHTOP OF CURBNOTES4312"1"SYNTHETIC TURF PERIMETER CURBFD-021" = 1'-0" Plot Date: 4/12/2024File: G:\28020.00\3.0_Working\3.9_CAD\1_SheetFiles\PERMITTING\24_0415 PERMIT SET\L8-10_FIELD DETAILS.dwgSaved By: arenaudSealDrawing No.Drawing Title:Key MapProject Title:Client Project No:Drawn By:Checked By:Approved By:Issue Date:04.19.2024SC, TS, JPAR, TS, SCAGDRAWING ISSUE & REVISION HISTORYNo.DescriptionDateSasaki Project No:NOT FOR CONSTRUCTION1183528020.00ARCHITECT + LANDSCAPE ARCHITECTSASAKI110 Chauncy StreetBoston, MA 02111TEL. 617.926.3300www.sasaki.comCIVILTG MILLER605 West State Street, Suite AIthaca, NY 14850TEL. 607.272.6477www.tgmillerpc.comSTRUCTURALLEMESSURIER1380 Soldiers Field RoadBoston, MA 02135TEL. 617.868.1200www.lemessurier.comMEP/FPRFS ENGINEERING71 Water StreetLaconia, NH 03246TEL. 603.524.4647www.rfsengineering.comBUILDING AND FIRE CODEHOWE ENGINEERS141 Longwater Drive, Suite 110Norwell, MA 02061TEL. 781.878.3500www.howeengineers.com04/19/2024ISSUE FOR PERMITIndoor Sports and RecreationCenter & Multi-Purpose FieldTower RoadIthaca, NY 14853Cornell UniversityNorthScale: 1" = 20'FLAG POLESCALE: NTS1.ADJACENT PLANTING OR PAVING2.SYNTHETIC TURF SYSTEM3.PERIMETER TURF CURB4.60" NET POST EMBEDDMENT5.#4 HOOPS @ 12" O.C.6.CAST-IN-PLACE CONCRETEFOOTING7.(6) VERTICAL #8 BARS8.6" DIA X 30' TALL FIELD NETTINGPOSTA.SEE SPECIFICATIONS FOR NETTINGDETAILSB.SEE LAYOUT & MATERIALS PLANFOR NET POST SPACING.C.CONTRACTOR TO CONFIRMFOUNDATION SIZE WITHMANUFACTURER.617854LEGENDNOTES3'7'-0" 6'-0" 5'-0"14"3212"57PLAN - FOOTINGFIELD NET POSTSCALE: 1"=1'-0"16' 6'2'66617D5SECTIONELEVATION1.FENCE POST2.SYNTHETIC TURF SYSTEM3.SYNTHETIC TURF PERIMETER CURB X/LX-XX4.ADJACENT PLANTING OR PAVING (SEE MATERIALSAND GRADING PLANS)5.DENSE GRADED AGGREGATE BASE6.TOP, BOTTOM, AND MID RAIL.7.VINYL COATED CHAIN LINK FABRIC8.WINDSCREEN9.12" HIGH CHAIN LINK PAD WITH RIGID BACKING10.(4) #4 CONTINUOUS THROUGH CURB; 8" LAP11.#4 TIE @ 8' ON CENTERLEGENDNOTESA.SEE SPECIFICATIONS FOR FENCE MESH MATERIAL.B.FRONT OF FENCE POST TO ALIGN WITH FRONT OF NET POST.C.TOP OF FENCE FABRIC SHALL BE SET 12" BELOW TOP RAIL OF FENCE.D.CORE FENCE POST INTO CONCRETE CURB EVERY 8' OC. PROVIDESCORING JOINT IN CURBING AT EACH POST AND EXPANSION JOINTEVERY 3RD POST OR 24'.E.CHAIN LINK FABRIC AND WINDSCREEN ON FIELD SIDE OF FENCE.F.12" PAD SHOULD BE MOUNTED AT BOTTOM OF FENCE SET 1" ABOVETOP OF CURB. REFER TO DRAWINGS FOR EXACT LOCATIONS.814"2.00' (24")31052413"101'-9"119FENCE AT SYNTHETIC TURF PERIMETER CURBSCALE: 1"=1'-0"BLACK VINYL CHAIN LINK FENCESCALE: NTSFN-03FN-02FN-01FN-04FIELD DETAILS -FENCING AND NETTINGL8-11 1 PLANNING DEPARTMENT MEMORANDUM TO: Planning Board Members FROM: Christine Balestra, Senior Planner DATE: May 13, 2024 RE: Revisions to Town of Ithaca Official Map– Recommendation to the Town Board Enclosed please find a revised Town of Ithaca Official Map that illustrates the state, county, local, and private roads in the Town of Ithaca, along with state and town parks/trails, potential future road connections, and municipal boundaries. Also attached is a list of all new roads, updated road information, new trails, and other information since the last Official Map update (2020). The project is scheduled for consideration of a recommendation to the Town Board at the May 21, 2024, Planning Board meeting. New York State Town Law § 270 authorizes a town board to establish an Official Map of the Town, outside the limits of any incorporated city or village, showing the streets, highways and parks laid out, adopted, and established by law. New York State Town Law § 273 authorizes a town board, whenever and as often as it may deem it for the public interest, to change or add to the Official Map of the Town to lay out new streets, highways, drainage systems or parks. Among other things, a town board must refer proposed changes or additions to their planning board for a recommendation. The Town of Ithaca Official Map has been periodically updated throughout the years, beginning in 1968 and most recently in 2020. As indicated above, the Planning Board’s role is to review the Map and provide a recommendation to the Town Board. The Planning Board may request additional revisions in their recommendation. Among the attachments is a draft resolution of recommendation for the Planning Board to consider. Dan Thaete, Director of Engineering, and Ben Coakley, GIS Analyst, will be present at the May 21st meeting to answer questions related to the Official Map. Please feel free to contact me with any questions before the meeting at 273-1721 or by email at cbalestra@townithacany.gov. Att. PROPOSED RESOLUTION: Recommendation to Town Board Regarding Proposed Changes to Official Map Town of Ithaca Planning Board May 21, 2024 WHEREAS: 1. Section 270 of NYS Town Law authorizes the Town Board to establish an official map of that part of the town outside the limits of any incorporated city or village showing the streets, highways and parks theretofore laid out, and may also show drainage systems; 2. The current Official Map of the Town of Ithaca was last updated in 2020; 3. Section 273 of NYS Town Law authorizes the Town Board to change or add to the Official Map of the Town so as to lay out new streets, highways, drainage systems or parks, and any such change or addition to the Official Map must be referred to the Planning Board for a report thereon; 4. The Director of Engineering has prepared a draft proposed revised Official Map for 2024 showing the current and proposed streets, highways, and parks in the Town of Ithaca, which represents changes from the 2020 Official Map; 5. The Town of Ithaca Town Board discussed the draft revised Official Map, as described above, at its meeting on May 13, 2024, and referred the proposed changes to the Planning Board for a report and recommendation; and 6. The Town of Ithaca Planning Board reviewed the draft Official Map and held a public hearing on the draft Official Map at its meeting on May 21, 2024; NOW, THEREFORE, BE IT RESOLVED: That the Town of Ithaca Planning Board hereby recommends that the Town Board adopt the proposed revised Official Map with the changes shown on the 2024 draft. A vote on the motion was as follows: AYES: NAYS: Updates for the 2024 version of the official town map Add roads: Acer Dr (Cornell) Amabel Rd & Amabel Ln (private) Walters Way (private) (454 long from Elm St Ext centerline per Final Site Plan) Power Plant Way (private) Update roads: Larissa Lane Phase 3 is now Town-owned, not private. Crest Ln stops at end of pavement, and does not include the turn to the north (use County data) The Town poron of Pennsylvania Ave ends at the end of the pavement. The remaining approximately 143 feet is private. Indian Creek Rd stops at Happy Ln – the Town-owned poron to the east is not a Town highway Remove future approved road in Holochuck development Add label for Remington Rd W (partly in Town) Many miscellaneous road geometry updates, inherited from County GIS data Add Gateway Trail Update to new hydrology data Add all ponds over 1 acre Remove intermient unnamed streams Update Town road widths from 2021 Local Highway Inventory for most roads. Add missing widths for Sunnyview Ln and Remington Rd W. City of Ithaca Town of Danby Town of NewfieldTown of EnfieldTown of Ulysses Village of Cayuga Heights Town of Lansing Village of Lansing Town of DrydenBeebe Ithaca Reservoir Cayuga Lake Lake EastIthacaNaturePreserve WesthavenPreserve GlensidePreserve Pine TreeWildlifePreserve SalemPark TareytonPark HungerfordHeightsPark EasternHeightsPark Tudor GrandviewPark VincenzoIacovelliPark Northview Park Troy Park Saunders Park Coddington RoadCommunity Center Compton Park(undeveloped) Saponi Park(undeveloped) TuteloPark West HillPark Woolf Park(undeveloped) East Shore Park Park Allan H. TremanState Marine Park Buttermilk Falls State Park Robert H. Treman State Park Bla ck D iamond T ra i l ForestHomePark Culver Road Preserve Undeveloped park B l a c k D i am o n d T r a i l Warren RdBrandywine DrSalem DrElm St Ext Wa l n u t S tBurleighCampbell AveCoddington RdV e t e r a n s Sesame St Mitchell StWe t l a n d Maize Dr Rachel Carson TrlI nlet Rd Energy DrE a s t S h o re D r Sien a Dr Floral AveSanctuary Dr Dickman Cir Forest Home DrComfort Rd Tudor Rd Tibet Dr Grant Egbert Blvd E Mazza R d Juniper Dr Dr yden Rd Arbor e t u m Hal c yon Hill Rd Rapt o r Rd Hudson StSummerhill LnHopkins PlDanby RdLisa LnDu b o i s R d Trum a n s b u rg Rd Regency Ln S chic k el Rd Comsto c k Kno ll Dr T a u g h a n n o c k B lv d Teet e r Rd Lisa Pl Joey Ln Helios CirPennsylvania Ave Ext Winston Ct Jessup Rd Spruce WayMann Dr Shagbark LnHarris B Dates Dr Ext Alumni Cir E Sylvan LnLena StSlat e r v i lle Rd Indian Creek Rd Hansha w Rd S ynch r ot r on Ithaca Beer DrSnyder Hill Rd Maggie Ln Bookbank RdKendall Ave B irch wood Dr Cyp r ess Ct Bir c hwood Dr N Campu sCente rWay Medi cago D r Winthrop Dr Hackberry Ln Pearsall Pl Tareyton DrRocky Ln Textor Summerhi l l Plz St ra wberry Grove Pl Discovery DrSugarbush LnEldridge Cir Worth St Ellis Hollow Rd N Cayuga StRenwick DrEastern Hei g h t s D r Williams Sandra PlSky-VueRdSalem DrHonness Ln Ga l lus Rd Alison DrJa m e s L n Deerfield Pl AveBlackstonePar k LnPl e a san t Gr o v e RdProgram HouseNilo DrHayts Rd Texas Ln Ext Lois LnTau r u s Dr Wiedmaier CtCucurb it Dr Dove DrHarwickRdParvo DrCal d w e ll King R d WIvy Crest Tulip Tree DrPoole Rd Bundy Rd Vera CirCollegeBellaVistaCir Towerview DrTower Rd Vine StTuber D r B ur r ow Dr Five Mile Dr Woodgate LnGrove Rd Roat St Hasbrouck Cir Coni f er DrAm b e r L n LaGrandCtT r iticum Dr Peacht ree Ln Homestead TerButtermilk Falls Rd W College Cir LnMcIntyre Pl Sharlene RdOrchard StVista LnWin n e r s C i r Coy Gle n Rd Bre w e r y Ln Scholarly Way Con i f er Ln Burns WayChristopher Ln Ter racev iewHappy LnRose Hi ll Rd College Cir Dr Hungerford Hill RdCrest Ln Landmark DrP a lm Rd Southwoods D r Homestead Wil d f l o w e r D rConcord PlLevine CirEvergreen Ln Eastw o o d Ave Stone Quarry RdFidler Rd Pi n e T r e e RdCampus Rd Rosecomb Rd Pheasant L nWinston DrByway Conifer Swanson DrWesthaven RdSpencer RdPenn s y l vania Ave E Stat e S t R a c h e l C a r s o n Mcgee Rd Mecklenbur g Rd G rant Egbert B lvd Candlew y ck Re n wi c k Pl Saun d e r s R dAs t e r L n Sunnyview Ln Ecology Dr Kings Way Helen’s Wa y Sand Bank RdWes tview Ln Holly Creek View Dr Heights RdFair w a y Dr Whitetail D r Hosta DrBostwick Rd Judd Falls RdKay StWeepingWillow Cir Penny Ln Felis Dr Ma rcy Ct Culver Rd Sycamore Dr Enfield Falls Rd F arrier Rd Teton Ct Maplewood Dr Max’s Dr Bella Vista DrMcGowan Woods Rd Nort h view Lexington DrH i llc r e s t D r Butter m i l k Falls Rd E T ower Apple BlossomArrowwood Dr Perry LnNort hview Rd Crisp Apple DrSimsbury Dr Glenside Crad it Farm Dr Palustris Sa ran a c W ay Gray Rd John St Maple Ave Haller BlvdD rew Rd Sain t Cath e r i n e Cir West Haven DrChas e L n Rich RdW atertower RdConservatory DrOld Gorge Rd F a rm P o n d R d Ridgec rest RdChristopher Updike RdLarisa Ln Burns RdO rcha rd Hi ll Rd King Rd E Compton Rd Inlet Valley Calkins RdBluegrass LnWoolf Ln Flora Brown DrLyceum Dr Irade l l Rd Arbo r etum Rd Hi c k o r y Pl Pineview TerRd W Joanne DrHi l l C i r Dr Summ e r h i l l DrClover LnCi r Briarwood DrPinewood PlMuriel StDrWing DrR d Solidago RdGame Farm RdH a r r i s B D a t e s D r West H i l l C i rHopkins RdDr Gle n R d Cir Valley View RdRdLongview DrLnWay Seven Mile DrTownline RdElmira RdKing Rd WCir Skyline Dr CirBirdseyeCo d d i n g t o n R dRenwick La k e S tEast Shore DrSapsucker Woods RdWarren RdCirForest Home Dr Dr P lWay 109 110 110M 115 119 120 121 122 123 128 137 139 140 141 172 172 173 174 177 179Jessie LnTheWay Rd DrSheeld RdTroy RdArboretu m S e r v i c e R d Sand Bank Rd Wycko R dWest Hill DrLn Sheeld RdW h ite t a i l D r Blackstone AveDrElm St Ext109 121 119 179 123 137 172 Co d d i n g t o n R dWalters WayAmabel RdAmabel LnAcer D rRemington Rd WPower P lan t Way Williams Brook Pleasant G ro v e B r ook Fall C r eek Lic k B rook Fall Creek Cayuga InletCo y G l e n Si x M i l e C ree k Six M i l e C reek Cascadilla CreekIndian CreekCliff Park Brook Enfield Creek Bu t t e rm i l k C r e e k Six Mi le CreekRenwick Broo k TOWN OF ITHACA 2024 OFFICIAL MAP 0 1 2½Miles Town Trails and Walkways Roads Other Municipalities Cornell University* Ithaca College* State Highways Private* Tompkins County Town of Ithaca Town Parks (undeveloped) Town Preserves Parks and Trails Town Parks *Roads shown are not necessarily representative of town highway standards but recognized as established access routes. Road Width in feet Alison Dr 24 Amber Ln 22 Apple Blossom Ln 22 Aster Ln 20 Birchwood Dr 20 Birchwood Dr N 22 Blackstone Ave 22 Brandywine Dr 22 Briarwood Dr 22 Bundy Rd 20 to 28 Burleigh Dr 22 Burns Way 20 Buttermilk Falls Rd E 24 Buttermilk Falls Rd W 24 Caldwell Rd 20 to 22 Calkins Rd 20 Campbell Ave 22 Chase Ln 24 Christopher Cir 21 Christopher Ln 22 Clover Ln 20 Compton Rd 22 Concord Pl 22 Conifer Dr 28 Coy Glen Rd 21 Crest Ln 19 Culver Rd 21 Deerfield Pl 22 Dove Dr 22 Drew Rd 21 Eastern Heights Dr 22 Eldridge Cir 24 Elm St Ext 22 Evergreen Ln 20 Fairway Dr 20 Fidler Rd 20 Forest Home Dr 20 Glenside Rd 16 Gray Rd 21 Grove Pl 21 Grove Rd 21 Hackberry Ln 23 Halcyon Hill Rd 12 Haller Blvd 20 Happy Ln 22 Harris B Dates Dr 28 Harris B Dates Dr Ext 22 Harwick Rd 23 Helen's Way 12 Hickory Pl 20 Holly Creek Ln 20 Homestead Cir 26 Honness Ln 28 Hopkins Pl 20 Hopkins Rd 22 Indian Creek Rd 20 Joanne Dr 24 John St 21 Judd Falls Rd 20 to 24 Juniper Dr 20 Kay St 20 Kendall Ave 20 King Rd W 22 Kings Way 20 Landmark Dr 18 Larisa Ln 20 LaGrand Ct 22 Lexington Dr 20 to 21 Lisa Ln 20 Lisa Pl 24 Lois Ln 20 to 24 Longview Dr 24 Maple Ave 20 Maplewood Dr 21 Marcy Ct 23 Road Width in feet Max's Dr 21 McIntyre Pl 18 Muriel St 22 N Cayuga St 24 Northview Rd 23 Northview Rd W 23 Old Gorge Rd 28 Orchard Hill Rd 21 Orchard St 21 Park Ln 22 Peachtree Ln 22 Pearsall Pl 14 Pennsylvania Ave 22 Penny Ln 24 Perry Ln 24 Pheasant Ln 23 Pineview Ter 22 Pinewood Pl 21 Poole Rd 22 Regency Ln 21 Renwick Dr 21 Renwick Heights Rd 21 Renwick Pl 14 Rich Rd 22 Ridgecrest Rd 22 Roat St 20 Rose Hill Rd 22 Salem Dr 22 Sanctuary Dr 22 to 30 Sand Bank Rd 22 Sandra Pl 22 Sapsucker Woods Rd 22 Saranac Way 22 Saunders Rd 23 Schickel Rd 24 Sesame St 22 Seven Mile Dr 22 Sharlene Rd 21 Siena Drive 22 Simsbury Dr 20 Sky-Vue Rd 22 Snyder Hill Rd 22 Southwoods Dr 22 Spruce Way 28 Saint Catherine Cir 20 Stone Quarry Rd 24 Strawberry Hill Cir 23 Sugarbush Ln 22 Summerhill Ln 22 Sycamore Dr 22 Tareyton Dr 22 Terraceview Dr 22 Teton Ct 24 Texas Ln Ext 20 Towerview Dr 20 Townline Rd 22 Tudor Rd 22 Updike Rd 20 Valley View Rd 21 Vera Cir 21 Vista Ln 22 West Hill Dr 28 Westhaven Rd 21 Westview Ln 22 Whitetail Dr 23 to 24 Wildflower Dr 23 Williams Glen Rd 21 Winners Cir 23 Winston Dr 22 Winthrop Dr 28 Woodgate Ln 20 Woolf Ln 21 Wyckoff Rd 20 Official map of the Town of Ithaca effective XXXXXX XX, 2024. Adopted by the Town Board on XXXXXXX XX, 2024. Paulette Rosa Town Clerk Pavement width is not representative of Town right of way widths. 137 Town Road Pavement Widths State Parks/Land Boundaries Municipal BoundariesApproved Future Roads Remington Rd W 20 Sunnyview Ln 22 PB 2024-03-19 (Filed 5/2) Pg. 1 TOWN OF ITHACA PLANNING BOARD March 19, 2024 Draft Minutes Present: Caitlin Cameron, Vice Chair; Ariel Casper, Cindy Kaufman, Liz Bageant, Bill Arms and Kelda McGurk Absent: Fred Wilcox, Chair CJ Randall, Director of Planning; Christine Balestra, Senior Planner; Susan Brock, Attorney for the Town; David O’Shea, Senior Civil Engineer; Marty Moseley, Director of Code Enforcement; Paulette Rosa, Town Clerk Ms. Cameron opened the meeting at 6:30p.m. Mr. Arms noted for the record that he lives on the same block as the applicant for the Copman two-lot subdivision proposal, but he did not feel he had a conflict of interest. Item 1 Consideration of Preliminary and Final Subdivision Approval for a proposed two -lot subdivision, located at 210/212 Forest Home Drive within the Medium Density Residential Zone. The proposal involves subdividing the property so the main residence at 210 Fo rest Home Drive and the carriage house at 212 Forest Home Drive are on separate tax parcels. Linda Copman, Owner/Applicant. Johan Dulfer, Berkshire Hathaway Home Services Heritage Realty, Agent, gave an overview of the request, saying that the two parcels were separately owned and then consolidated in the 1990’s when owned by the same person. The applicant would like to return it to the same previously existing two parcels, live at 212 Forest Home Dr., and market 210 Forest Home Dr. for sale. The Board had questions regarding the three parking spaces in front of the property that are designated “private parking” and the references to a shared driveway and parking for both parcels. Mr. Dulfer responded that it is his understanding that the parking spots are on the parcel itself and legally non-conforming and permitted due to the lot line running to the center of the road, but it is in the public right-of-way and not considered off street parking. He has been discussing options with Mr. Moseley and a shared driveway had been included in the variance request to the Zoning Board; but that has since been removed, as the plan has changed to remove a small tree and make an independent driveway for the parcel. The Board discussed the proposed subdivision lines and the existing fencing that crosses parcel boundaries. Mr. Dulfer noted that the fence will be moved so that it is only on the one parcel. PB 2024-03-19 (Filed 5/2) Pg. 2 The Board discussed the need for an encroachment license with the Town for the snow fencing and arbor which encroach into the right-of-way. The arbor has been in place for many years and the trees and perpetual maintenance of them were required as a buffe r as part of a previously granted ZBA variance to allow the solar panels in the front yard. The road salt was killing the trees and the applicant put up the snow fencing to shield the tree roots from road salt. Mr. Arms noted that he has lived in the neighborhood for decades and houses are very old and pre-date zoning, so parking in front of homes has always been done and does not concern him. It was noted that Forest Home is a designated NYS Historical District, but this is a subdivision request, not a development request, and therefore historical elements do not come into play. SEQR Determination PB Resolution 2024-010: SEQR Preliminary & Final Subdivision Approval Copman 2-Lot Subdivision 210/212 Forest Home Drive Tax Parcel 66.-2-13 Whereas: 1. The proposal is the consideration of Preliminary and Final Subdivision Approval for a two - lot subdivision, located at 210/212 Forest Home Drive, Medium Density Residential Zone. The proposal involves subdividing the property so the main residence at 210 Fo rest Home Drive and the carriage house at 212 Forest Home Drive are on separate tax parcels. The property was once separate parcels that were consolidated in 1990. No development is proposed. This is an Unlisted Action under the State Environmental Quality Review Act and is subject to environmental review. Linda Copman, Owner/Applicant; Johan Dulfer , Berkshire Hathaway HomeServices Heritage Realty, Agent, 2. This is an Unlisted Action for which the Town of Ithaca Planning Board is the lead agency in the environmental review with respect to the project, 3. The Planning Board on March 19, 2024, has reviewed and accepted as adequate a narrative, a subdivision plat titled “Subdivision Plat of Lands at No. 210 & 212 Forest Home Drive, Town of Ithaca, Tompkins County, New York,” prepared by Ian M. Sheive, License d Land Surveyor, Sheive Land Surveying, dated 7/25/2013 and last revised 03/19/24, and other application materials, and 4. Town planning staff has recommended a negative determination of environmental significance with respect to the proposed Subdivision Approval; now, therefore be it Resolved: That the Town of Ithaca Planning Board hereby makes a negative determination of environmental significance in accordance with Article 8 of the Environmental Conservation Law PB 2024-03-19 (Filed 5/2) Pg. 3 and 6 NYCRR Part 617 New York State Environmental Quality Review for the above referenced action as proposed, based on the information in the EAF Part 1 and for the reasons set forth in the EAF Parts 2 and 3, and, therefore, an Environmental Impact Stateme nt will not be required. Moved: Ariel Casper Seconded: Elizabeth Bageant Vote: ayes – Casper, Arms, Bageant, Kaufman, Cameron, and McGurk Public Hearing Ms. Cameron opened the public hearing at 7:00p.m.; there was no one wishing to speak, and the hearing was closed. Determination The draft resolution was revised to remove the reference to a shared driveway, revised dates of submitted materials, and a condition added requiring the encroachment agreement with the Town. PB Resolution 2024-011: Preliminary & Final Subdivision Approval Copman 2-Lot Subdivision 210/212 Forest Home Drive Tax Parcel 66.-2-13 Whereas: 1. This is consideration of Preliminary and Final Subdivision Approval for a two-lot subdivision, located at 210/212 Forest Home Drive, Medium Density Residential Zone. The proposal involves subdividing the property so the main residence at 210 Forest Home Drive and the carriage house at 212 Forest Home Drive are on separate tax parcels. The property was once separate parcels that were consolidated in 1990. No development is proposed. This is an Unlisted Action under the State Environmental Quality Review Act and is subject to environmental review. Linda Copman, Owner/Applicant; Johan Dulfer, Berkshire Hathaway HomeServices Heritage Realty, Agent, 2. This is an Unlisted Action for which the Town of Ithaca Planning Board, as lead agency in the environmental review with respect to the project, has on March 19, 2024, made a negative determination of environmental significance, after having reviewed and accepted as adequate a Short Environmental Assessment Form Part 1, submitted by the applicant, and Parts 2 and 3 prepared by the Town Planning staff, 3. The Planning Board, on March 19, 2024, has reviewed and accepted as adequate a narrative, a subdivision plat titled “Subdivision Plat of Lands at No. 210 & 212 Forest Home Drive, Town of Ithaca, Tompkins County, New York,” prepared by Ian Sheive, Licensed Land Surveyor, Sheive Land Surveying, dated 7/25/2013 and last revised 03/19/24, and other application materials, and PB 2024-03-19 (Filed 5/2) Pg. 4 4. Per the Inter-governmental Agreement between the Town of Ithaca and the Tompkins County Planning and Sustainability Department, dated August 3, 2004, residential subdivisions of fewer than 5 lots, all of which comply with local zoning standards and Tompkins County Sanitary Code requirements, and do not involve new local roads or streets directly accessing a State or county road, are of local, rather than inter -community or county-wide concern, and are therefore not subject to referral to the Tompkins County Planning and Sustainability Department under New York State General Municipal Law, Article 12-B, §§239-l, -m, and -n; now, therefore be it Resolved: 1. That the Planning Board hereby waives certain requirements for Preliminary and Final Subdivision Approval, as shown on the Preliminary and Final Subdivision Checklists, having determined from the materials presented that such waiver would result in a significant alteration of neither the purpose of subdivision control nor the policies enunciated or implied by the Town Board; and 2. That the Planning Board hereby grants Preliminary & Final Subdivision Approval for the proposed Copman 2-Lot Subdivision, as shown on the plans noted in Whereas #3 above, subject to the following conditions: a. Receipt of any necessary variances from the Zoning Board of Appeals, b. Submission for signing by the Chairperson of the Planning Board of an original and three dark lined prints of the final subdivision plat, prior to filing with the Tompkins County Clerk Office; and submission of a copy of the receipt of filing to the Town of Ithaca Planning Department, c. Prior to signing of the plat by the Chairperson of the Planning Board, entry into an encroachment license with the Town to allow encroachment of the plastic deer fence and arbor into the Forest Home Drive right-of way, and d. A new water service shall be installed to 212 Forest Home Drive within six months of filing the subdivision plat in the Tompkins County Clerk’s Office, or prior to a transfer of ownership of either parcel, whichever comes first. Moved: Ariel Casper Seconded: Cindy Kaufman Vote: ayes – Casper, Arms, Bageant, Kaufman, Cameron, and McGurk Item 2 Persons to be Heard Yayoi Koizumi, Zero Waste Ithaca, spoke saying that she was concerned about the lack of transparency in the decision making process regarding the Board’s negative declaration of environmental significance for the Cornell Fieldhouse project. Ms. Koizumi referenced the apparent disappearance from the new agenda packet of the negative PB 2024-03-19 (Filed 5/2) Pg. 5 determination, saying that the Board appears to have made it without ample public scrutiny or thorough consideration given the significant concerns surrounding synthetic turfs and the potential environmental and health impacts as well as life cycle considerations. She said the negative declaration decision, presumably made after the people who spoke against the turf left the previous meeting, with the YouTube video of the meeting showing no decision making process on the determination and the agenda packet uploaded on February 21st with SEQR comments has disappeared from the new agenda packet. Ms. Koizumi thanked Ms. Kaufman for questioning the safety of artificial turf and noted that the Conservation Board had also sent a letter expressing concerns. Ms. Koizumi’s second comment concerned Mr. Wilcox’s responses to their comments at the last meeting, saying that while the speakers respect the perspectives shared by board members, they believe it is crucial to recognize the importance of considering health impacts regardless of jurisdictional boundaries and the community's well-being should always be a priority, with decisions made by Planning Board reflecting a commitment to safeguarding the public health and environment by taking into account public opi nion, scientific evidence on the synthetic turf chemicals and adopting precautionary principles. Her third comment was a response to Mr. Arm’s comment, saying that while they appreciate his perspective, they believe it is essential to acknowledge the validity of concerns raised regarding synthetic turf rather than dismissing these concerns as emotiona l and they urge decision makers to engage with them and review the extensive research available to them to ensure the wellbeing of those affected are going to be considered. Bethany Ojalehto Mays, speaking about her comments made at a prior meeting, saying she was confused also about that meeting because the agenda item for the Cornell Field had been pulled, but we were allowed to speak. Then the next day, a letter, signed by Chairman Wilcox was sent to the City of Ithaca Planning Board stating that a unanimous negative declaration of environmental significance had been made by the Town’s Planning Board. She said she would really appreciate it if this could be explained. Ms. Randall responded, saying that the letter being referenced from the Town to the City is a letter stating that the Town agrees and concurs with the City’s Planning Board to act as Lead Agency in the environmental review and we are not aware of any negat ive declaration being made. Ms. Ojalehto Mays read directly from the letter dated February 20th to the City. “The Town of Ithaca Planning Board met on February 20, 2024, to make a recommendation to the City of Ithaca Planning and Development Board on whether the Cornell Meinig Fieldhouse project could have the potential for at least one significant adverse environmental impact. Planning Board members were unanimous in their opinion that the project did not rise to the level of potential significant adverse environmental impact and thus recommend that the lead agency issue a negative PB 2024-03-19 (Filed 5/2) Pg. 6 declaration of environmental significance.” She said this is why we are confused as people and board members expressed concerns about the impacts. Ms. Balestra responded that the letter Ms. Ojalehto Mays just read was a draft letter that was in the packet that was sent to members and posted to the web prior to staff finding out just before the meeting started that the item was being pulled. The letter was not signed by the Chair, not sent, and was drafted by staff. There has been no official determination on the level of environmental significance of this project. Mr. Casper stated that our open transparency is the root of your issue here because staff is so transparent that they post everything that will be discussed at a meeting and you then have access to it, because this board and our staff does our job so well and documents are available even if they become null and void, so the accusation that we are not transparent does not sit right with him. Ms. Ojalehto Mays responded that she did not make that accusation and thanked everyone for the explanation and details, saying this has been very helpful, and it was interesting that drafts were produced prior to a meeting, but that is another question for another time, but this had been helpful, and she did not want to accuse anyone of a lack of transparency. Ms. Bageant said she does understand how this can be very confusing to the public because drafts are prepared, so no offense taken, but it is very valuable to her at least, to have staff putting together drafts for the board to consider rather than having to attempt to compose them during the meeting. She said she would like the public to understand that the drafts are discussed and can be and often are changed, but having the framework is extremely helpful. Mr. Arms asked about the Town’s ability to consider environmental impacts outside of the Town boundaries. Ms. Brock responded that for site plan, the board can only consider what is in the Town; for environmental review, the board can make comments about impacts of the whole project, but the City has been made the Lead Agency as most of the project is in the City of Ithaca. The Town can submit comments to the Lead Agency for their consideration in making the determination. Ms. Rosa added a final comment regarding transparency, saying that the packets are located online on the town website, under Current Agendas, until after the meeting, when they are moved to the Planning Board folder under Packets by year, and the State LGS1 retention is 6- years, but the Town chooses to keep the documents permanently. They do not “disappear” but are rather filed in the appropriate location, accessible to the public forever. Ms. Bageant added that the public can always call the Town Clerk if they have any issue locating a public document. Ms. Ojalehto Mays thanked the Board for the thorough response and explanation and PB 2024-03-19 (Filed 5/2) Pg. 7 apologized if the accusation of not be transparent was felt and unfounded. Item 3 Approval of Minutes February 6, 2024, and February 24, 2024 minutes were moved for approval by Mr. Casper, seconded by Ms. Bageant; unanimous. Item 4 Other Business Ms. Randall reported that the Town is working with the Town of Lansing to provide a joint training on May 13th at 6pm on Site Plan and Area Variances. Ms. Balestra reported that there are no actions for the April 2nd meeting. Motion made by Ms. Cameron to cancel the April 2, 2024, meeting; seconded by Ms. Kaufman, unanimous. Ms. Kaufman asked about getting an expert to come in to help the board understand the issues around artificial turf versus the maintenance and upkeep of grass turf. She said she is overwhelmed by the amount of information out there. Discussion followed, with members saying they would like to be informed, but also to know when and where in the SEQR the board is supposed to consider this type of information. Ms. Balestra referenced The SEQR Handbook as well as the environmental assessment forms. Ms. Randall cautioned about third-party or independent expertise being brought in because, hypothetically, an applicant could present one version of “expert data” and the public or others present another version of “expert data.” It is the board’s responsibility to evaluate the different opinions and decide. Ms. Brock added that she does not really encourage doing independent research because everything used to make your determination should be in the official record; something that has been submitted or that you have submitted yourself to staff so they can provide it to the public. Ms. Randall noted that there are topical fact sheets available from the DEC. Discussion followed with members concerned that that stance would limit them from becoming informed about aspects of projects they are not familiar with, while sometimes they may have personal expertise in an area and not need additional information. Members felt trying to submit information they have accessed in time for the packet mailout would be problematic and a topic may not even be apparent until the packet is received. Mr. Arms said we should be encouraged to do our own research and come to meetings prepared , noting that when the Ithaca College field was under consideration, the applicant submitted extracts of fact sheets and he read the full fact sheet. Ms. Brock reiterated that the information members are basing their decisions upon should be PB 2024-03-19 (Filed 5/2) Pg. 8 available to everyone and decisions must be based on information in the public record. Different scenarios of issues that could make members want to research more were discussed, with Ms. Brock bringing it back to the artificial turf, saying that under SEQR, the environmental effects can be considered by this board to then make comments to the City’s Planning and Development Board to weigh in their determination as Lead Agency on the SEQR determination. The meeting was adjourned upon motion by Mr. Casper, seconded by Ms. Bageant; unanimous. Submitted by Paulette Rosa, Town Clerk PB 2024-05-7 (Filed5/9) Pg. 1 TOWN OF ITHACA PLANNING BOARD May 7, 2024 Draft Minutes Present: Caitlin Cameron, Vice Chair, Ariel Casper, Cindy Kaufman, Liz Bageant, Bill Arms, and Kelda McGurk Absent: Fred Wilcox CJ Randall, Director of Planning, Christine Balestra, Senior Planner; Susan Brock, Attorney for the Town; Marty Moseley, Director of Code Enforcement; and Paulette Rosa, Town Clerk Ms. Cameron opened the meeting at 7:00p.m. Agenda Item 1 Consideration of Preliminary and Final Site Plan Approval for the Soil Factory, a Project of Weave Community, located at 142 Ithaca Beer Drive within the Light Industrial Zone and Inlet Valley Center Overlay District. The project involves establishing soil research test gardens on the site, along wi th multi-disciplinary meeting, workshop, and event spaces classified as Community Workshop and Place of Assembly uses in the existing buildings. Site improvements include delineating bicycle, vehicle, pedestrian circulation, and parking areas. There are no proposed exterior changes to the existing buildings. This is a Type II Action under the State Environmental Quality Review Act and is not subject to environmental review. Greentree Ithaca, LLC, Owner; Neil Schill, Applicant/Agent. Overview Mr. Schill, agent, and Mr. Gaunt, property owner, gave an overview of the project, saying that it is a place for artists, scientists, and community members to get together and learn and participate in a wide variety of activities. They said they were very excited to be part of the concept of the Inlet Valley Overlay District. The Board had questions about the parking layout and the safety of those entering and exiting the warehouse. The Board discussed different mitigation options. Mr. Gaunt stated that they had enlisted Claudia Brenner, architect, for planning the layout of the site, including the parking and they have as wide a space as possible between the warehouse and the parking lot travel lanes. They might consider using bollards or other options to clearly delineate the driving lane and the entrance way. He added that one part of the request is for fewer parking spaces than are required by Town Code but they may add a few back in once the spaces are delineated. Public Hearing Ms. Cameron opened the public hearing; there was no one wishing to speak, and the hearing was closed. Discussion/Determination PB 2024-05-7 (Filed5/9) Pg. 2 The Board discussed noise issues, noting the comment received by a neighbor expressing concerns, and the applicant assured the Board that their patrons now fully understand the parameters of the Town’s noise ordinance and they want to be good neighbors, and the issue that prompted the noise complaint to the Town will not happen again . He added that they do have an unwritten agreement with the neighboring business that they can use their parking lot during non-business hours. Ms. Bageant stated that she didn’t have any concerns about parking or the size of the spaces , adding that, in terms of the Planning Board’s need to allow parking in the required front yard, the nature of the site and the use lends itself to parking in the front, as it doesn’t really look like a front yard. Ms. Kaufman asked the applicant if they would consider a 5-foot pedestrian walkway along the front of the building, instead of a 3ft walkway. She also suggested that something be done to enhance the looks of the warehouse, such as adding a mural. Staff explained that the town has a mural law, and they would work with the applicants to see if that was a possibility they were interested in pursuing. Mr. Moseley explained the need for specific driving lane widths to accommodate fire truck access in the case of emergency. Right now, there is just under 20-feet between the warehouse and the loading dock, and the applicant is proposing at least 3 feet for pedestrian access. If you expand the front access to 5 feet or add bollards, you will reduce the driving lane which could restrict emergency access. Mr. Gaunt asked for more information regarding Mr. Moseley’s comment about emergency access. Mr. Moseley stated that they could work with the Fire Department on the bollard options and any concerns they may have. Mr. Arms said it is great to see this idea and although the buildings are not ideal, it is a great concept. He asked how big events would be – how many people would be expected to attend events. Mr. Schill responded that they have a maximum of 49 people at events. Ms. Cameron said she was comfortable with the ideas expressed and agreed that the front yard on this property is not really a front yard. Mr. McGurk asked if the lighting outside is enough to be safe for people walking outside. Mr. Gaunt said there are additional lights around the building that are not currently used. There is a light at each end and around the exterior of the warehouse as well as lights at each entrance/exit door that would come on when the door is opened, as well as outside lights around the perimeter. He said that right now, many of the fixtures do not have bulbs in them because he doesn’t like light pollution either. PB 2024-05-7 (Filed5/9) Pg. 3 Ms. Balestra noted that the Town has a lighting ordinance focused on reducing light pollution, but the lighting that exists were considered existing, non-conforming lights that could be used if they were not changing it. If they were to pursue additional lighting or changes to the existing lighting, they would need to meet the requirements in the Town Code, Outdoor Lighting, Chapter 173. PB Resolution 2024 - 012: Preliminary & Final Site Plan Approval The Soil Factory – A Project of Weave Community 142 Ithaca Beer Drive Tax Parcels 33.-3-2.3 & 33.-3-2.5 Whereas: 1. This action is the consideration of Preliminary and Final Site Plan Approval for the Soil Factory, a Project of Weave Community, located at 142 Ithaca Beer Drive within the Light Industrial Zone and Inlet Valley Center Overlay District. The project involves establishing soil research test gardens on the site, along with multi -disciplinary meeting, workshop, and event spaces classified as Community Workshop and Place of Assembly use s in the existing buildings. Site improvements include delineating bicycle, vehicle, pedestrian circulation, and parking areas. There are no proposed exterior changes to the existing buildings. Greentree Ithaca, LLC, Owner; Neil Schill, Applicant/Agent, 2. This is a Type II Action, pursuant to 6 NYCRR Section 617.5(c)(18) of the regulations of the New York State Department of Environmental Conservation promulgated pursuant to the State Environmental Quality Review Act, as the action constitutes a “reuse of a residential or commercial structure, or of a structure containing mixed residential and commercial uses, where the residential or commercial use is a permitted use under the applicable zoning law or ordinance, including permitted by special use permit, and the action does not meet or exceeds any of the thresholds in section 617.4 of this Part ,” and thus, approval of the site plan is not subject to review under SEQR, 3. The Planning Board, at a public hearing held on May 7, 2024, has reviewed, and accepted as adequate an undated narrative, a Basis of Design report prepared by Hallam ICS, dated 08/09/2022 (revised 06/12/2023), site plans titled “The Soil Factory, 142 Ithac a Beer Drive, Ithaca, NY14850,” including Sheets C1 and C2, prepared by Claudia Brenner, dated 04 -02- 2024, and other application materials, and 4. Project plans, and related information, were duly delivered to the Tompkins County Planning and Sustainability Department per New York State General Municipal Law §§239 -l et seq., and such Department responded in a April 24, 2024, letter from Katherine Borgella, Tompkins County Commissioner of Planning, pursuant to §§239-l, -m, and -n of the New York State General Municipal Law, determining that the proposed action will have no significant county-wide or inter-community impact; now, therefore be it Resolved: PB 2024-05-7 (Filed5/9) Pg. 4 1. The Planning Board hereby waives certain requirements for Preliminary and Final Site Plan Approval, as shown on the Preliminary and Final Site Plan Checklists, having determined from the materials presented that such waiver will result in a significant alt eration of neither the purpose of site plan control nor the policies enunciated or implied by the Town Board, 2. The Planning Board hereby grants Preliminary and Final Site Plan Approval for the proposed modifications to the Soil Factory, a Project of Weave Community, as described in the items noted in Whereas # 3 above, subject to the following condition: a. Before issuance of a building permit, submission of proof of right to access Ithaca Beer Drive (unimproved road), satisfactory to the Attorney for the Town, 3. Pursuant to Section 270-227 (A) (2) and (3) of the Town Code, the Planning Board hereby authorizes a 9% reduction in the number of required parking spaces for the project, finding that the reduction in the required number of parking spaces will not adversely affect traffic flow on the project site, will leave adequate parking for all of the reasonably anticipated uses or occupancies in the project, and will not otherwise adversely affect the general welfare of the community, 4. Pursuant to Section 270-227 (A) (4) of the Town Code, the Planning Board hereby authorizes a reduction in the standard 180 square foot parking space size, to no less than 162 square feet, finding that the reduction will not cause any adverse effects on the project, on the surrounding properties, or on the neighborhood, and 5. Pursuant to Section 270-227.B (2) and (3) of the Town Code, the Planning Board hereby authorizes the placement of parking in the required front yard of the project site, finding that: a. The particular use, nature, or location of the proposed project or building, requires that parking be in one of such yards, b. It is not practicable to limit parking to areas outside the required yard, c. Parking in such yard does not significantly adversely affect adjacent properties or the character of the neighborhood, and d. No such parking will occur in any buffer areas. Moved: Ariel Casper Seconded: Bill Arms Votes: ayes – Cameron, Casper, Arms, McGurk, Kaufman and Bageant Item 2 Other Business Ms. Balestra reviewed the next meeting’s agenda. Meeting was adjourned upon a motion by Mr. Casper, seconded by Mr. Arms; unanimous. Submitted by Paulette Rosa, Town Clerk ATTACHMENT 1 – PB minutes 5-21-24 Written comments submitted to the Ithaca Town Planning Board Regarding Cornell’s proposal for Meinig Field House May 21, 2024 bethany ojalehto mays Dear Town Planning Board Members; I am a mother and citizen of Ithaca. I have a PhD in Psychology specializing in environmental decision-making, and worked as an Assistant Professor of Human Development at Cornell before leaving to engage more directly with the climate crisis. Thank you for serving on this Board, and thank you for considering this written comment. Responding to the climate crisis requires wise decision-making for future generations. You are on the frontlines. As a Planning Board, the decisions you make will transform the composition of our soil, land, water, and determine carbon emissions for years to come. It is not an exaggeration to say that our fate lies partly in your hands. I offer this comment with gratitude to you for taking on this responsibility. There are significant climate concerns about Cornell’s proposed Meinig Field House and artificial turf fields. I will address those concerns in other spoken and written comments. For today’s comment, I want to focus on Cornell’s evaluation of the health and environmental impacts of artificial turf specifically. In their Meinig Field House Packet, Cornell included an “informational letter” from the consulting firm Haley & Aldrich that claimed to provide a summary of research on the health and ecological impacts of artificial turf. It was not a scientific review, but a one-sided report that relied heavily on industry reports that were not peer-reviewed scientific articles (as implied) and contained a number of concerning misunderstandings. Those points are detailed below, but first I want to speak to the dimensions of debate. THE DIMENSIONS OF THE “DEBATE” Planning Boards are often presented with what appear to be two sides of a debate: one from industry and one from concerned citizens and scientists. We can step back and ask: who benefits from each narrative in this debate? The artificial turf industry has the goal of maximizing their profits; they present evidence that artificial turf is safe. Concerned citizens and scientists have the goal of maximizing the common good; they present evidence that artificial turf has significant health and ecological harms. How do we weigh these two narratives? Artificial turf companies are businesses. Haley & Aldrich is a business. They are hired by companies to compile research reviews that will help those firms make more money. We have no reason to expect that the artificial turf industry sees a transparent or precautionary approach to health, ecological, and climate impacts of artificial turf as benefiting their bottom line. Any research review from industry should be interpreted with a precautionary awareness that the review may be biased toward their own profit. I join many others in speaking up as a concerned citizen and scientist. I offer this research and public comment as a volunteer. I make no money from this work. I have nothing at stake personally, except how much I care about stewarding lands, waters, and ecosystems that support wellbeing for all living beings. Thus, any research review that you receive from me may be “biased:” I am biased towards a precautionary principle to protecting human and ecological health from irreversible consequences, and I am biased toward actions and decisions that will preserve a habitable planet. Not all debates are genuine, and not all information is equal. Some information is designed to make more money for fossil fuels. That should be called out as disinformation, as the recent US Congressional Report on Big Oil’s disinformation highlights. Big Oil has undertaken a decades-long campaign designed to skew our understanding of the climate costs of fossil fuels, often through misinformation masked as “science.” Artificial turf is part of Big Oil: it is a fossil fuel product. As outlined below, I respectfully offer that Cornell’s current campaign to present artificial turf as safe and harmless is another instance of Big Oil’s misinformation masked as “science.” I have heard it said that concerned citizens and scientists are biased because they are “advocates” for the common good. That’s accurate as far as it goes, but it doesn’t go far enough. We must also acknowledge that industry is biased: they are advocates for their own profit. Everyone is biased because everyone has a perspective. Just as it is impossible to take a photograph without adopting a perspective, it is impossible to ask a question and find an answer without introducing a perspective: and that includes scientists. With that in mind, we should acknowledge that every research project and every building proposal is biased because it introduces a perspective. The question is: is it biased toward the common good? There are many cases in which it is smart to be biased. For instance, it is smart to be biased toward survival. I hope our Town Planning Board is biased toward protecting a habitable ecosystem where all of us can survive and thrive. On that note, I highly recommend that Town Planning Board members watch the expert panel of scientists and advocates who presented on artificial and natural turf at Zero Waste Ithaca’s recent webinar, and read the 2023 Sierra Club’s Public Health Risks of Artificial Turfs submitted to the Santa Clara County Board of Supervisors. It reflects many of the same problems which I now turn to outline with the Haley & Aldrich research review below. MISINFORMATION: The information letter by Haley & Aldrich is not sound science I was disappointed to see Cornell’s information letter from Haley & Aldrich. The letter claims to provide a “summary of recently published studies and reports that evaluate the safety (health and environmental risks) of using synthetic turf athletic fields.” Instead, it presents exclusively pro- industry research findings to the exclusion of the rest of the peer-reviewed scientific literature. This one-sided summary of research is designed to be comforting rather than informative. I list significant problems and questions below. (1) The letter is transparently pro-industry. Despite its claim to "summarize” the evidence, the letter does not provide a balanced summary of the evidence or evaluation of competing findings, as you would expect from any scientific review (see appendix). It does not review any of the research showing negative health and ecological impacts of artificial turf. As a basic measure of scientific rigor, one would expect a review to survey the relevant literature, address conflicting findings, and evaluate their merits, rather than presenting a cherry-picked selection of studies that say only one thing. (2) The letter contradicts its own standard of evidence. After pointing out the need to rely on peer reviewed scientific literature and claiming that “peer reviewed scientific studies were used to support the conclusions developed in this memorandum,” the authors of the letter then go on to contradict their own advice by relying heavily on two industry reports that were not peer-reviewed scientific articles, and a set of test results from Labosport that are not peer-reviewed. (3) Industry reports are presented on par with peer-reviewed scientific research. The letter approvingly cites reports authored by consulting firms and industry (TetraTech, TRC Companies) and treats them as reliable research, despite the fact that those reports were not peer-reviewed scientific articles. The report by TetraTech was reviewed by another consulting firm (the Horsley Witen Group), but this does not amount to peer-reviewed scientific research. Furthermore, the testing results presented from Labosport International are results from a single lab, not a scientific research program. Research conducted by and for the synthetic turf industry should not be considered on par with peer-reviewed scientific articles, in part because industry has a profit motive in undertaking research. (4) The informational letter does not address the climate costs of artificial turf. Natural grass fields absorb CO2 and produce oxygen, whereas artificial turf fields do exactly the opposite, emitting CO2, methane, and other greenhouse gases. Any institution that claims to care about carbon emissions should not be replacing natural grass fields with artificial turf fields that will intensify emissions while polluting the environment for decades to come. This is exactly the kind of land use pattern and resource consumption that is destroying our climate and our ecosystems, pushing us past multiple planetary boundaries at once. (5) The informational letter presents arguments based on background contamination that is not credible. The informational letter implies that PFAS found in artificial turf are unproblematic because the levels are “negligible” compared to background levels in soil: “Evaluation of the PFAS detected in the Tetratech (2021) and TRC (2022) studies [note: neither of which are peer-reviewed scientific articles] indicate that fewer PFAS compounds were detected in synthetic turf, and at lower concentrations, than those that are present as a background condition in soil.” This is not a credible argument. It is simply wrong to argue that because the soil is already so contaminated, further contamination doesn’t matter. First, this would only be the case if PFAS pollution followed a surprising nonlinear dose-response relationship where once you reached a certain level of pollution, nothing else above that mattered for the relevant outcome measures (health or environmental). That’s not how pollution works. We have every reason to expect that more pollution will be more harmful, both for humans and the environment. Second, this argument is circular, and it is designed to deny accountability for both past and future pollution. Current levels of background soil contamination are so high precisely because the industry hasn’t been regulated. Aldrich & Haley appear to see that as evidence for why industry shouldn’t be regulated going forward. Quite the opposite. High levels of contamination in soil and water provide urgent evidence for the need to start regulating industry now. (6) The report contains a recycling claim that requires further evidence: "During the field replacement process, the existing turf will be recycled." In a 2021 Massachusetts hearing, synturf industry industry representative Mark Curran admitted that not a single artificial turf field has been recycled to date. Likewise, the CEO of Re-Match Turf Recycling said in 2020 that “there is no synthetic turf recycling plant in America yet.” A 2023 Beyond Plastics Report found that Exxon Mobil’s claims to engage in “advanced chemical recycling” of plastic waste including artificial turf is toxic, unregulated, and unlikely to constitute recycling. If Cornell believes their artificial turf will be one of the first examples of successful recycling, then they should detail exactly what their plan is for “recycling” the turf, backing this up with transparent information on how and where the recycling will happen. (7) I have significant reservations and questions about the informational letter’s presentation and interpretation of testing results for metals and toxins based in part on industry reports. First, all reported tests use screening levels for direct contact and protection of groundwater. These are not the relevant thresholds if you're concerned about ingestion or absorption of these materials into the human body (which have more stringent thresholds). Second, the informational letter presents findings that artificial turf contains many heavy metals and toxins, including lead and PFAS, but dismisses these as unlikely to cause harm because they are below the chosen screening levels. The truth is, no known level of exposure to lead or PFAS is safe. The EPA recently announced that no known levels of PFAS ‘forever chemicals’ are safe, and the EPA sets the maximum contaminant level goals (MCLGs) for lead at zero: “EPA has set this level based on the best available science which shows there is no safe level of exposure to lead. The fact that there is no safe level of exposure underscores the fact that any action to reduce exposures can have impacts on lives and livelihoods.” The Town and City Planning Boards have the opportunity to take action now to reduce exposures by saying no to artificial turf. Third, the informational letter acknowledges that some of the metals and toxins did in fact exceed screening limits for direct contact and/or protection of groundwater (including cobalt, zinc, benzo(a)pyrene, and aniline). However, they then argued that these are “not harmful” because the “EPA (2019) concluded that only 3% of the metal concentrations reported in the crumb rubber samples are available for exposure.” Is it common practice to argue that the screening levels are not themselves useful, but should instead be transformed by an exposure factor? Without careful justification for this additional step, the reasoning appears post hoc. Screening levels for direct contact and groundwater contamination should be respected. (8) The report sets a deceptively high bar for proof of risk combined with highly tailored language – exactly as Big Tobacco did for decades. The informational letter states that over 100 peer-reviewed scientific studies have been conducted on health risks associated with crumb rubber turf fields, and then states: “We are not aware of any peer-reviewed scientific studies which draw an association between adverse health effects and use of crumb rubber.” This statement is either inaccurate, intentionally misleading, or sets the wrong standard for proof. It is simply inaccurate to state that no study has reported significant health risks of tire crumb infill. Many empirical studies have highlighted risks based on toxicity results, potential accidental ingestion, ecotoxicology, animal experiments, and limited human epidemiology (see Appendix B). Assuming the consultants are aware of these studies, their statement can only be interpreted as setting a deceptively high bar for proof of risk. It is exceptionally hard to demonstrate a significant association between a specific toxin and adverse health effects in humans (and it may require that people actively suffer the consequences in order to be studied). That does not invalidate the many other data sources that can and should be used to assess potential health risks of artificial turf, as cited above. The consultants appear to be replicating a strategy that Big Tobacco employed for decades. First, they ask us to assume that artificial turf is safe until proven otherwise. There is strong evidence to assume that it’s unsafe until proven otherwise – but the industry has shifted the burden of proof onto the public while their product continues to generate profit. Second, Haley & Aldrich present a deceptively high bar for proof of health risks. For decades, Big Tobacco sowed doubt about the conclusiveness of links between smoking and cancer, arguing that there was no “causal proof” for the association. They were right, but their standard of evidence was dead wrong. It was only in 1996 – 32 years after the US Surgeon General declared cigarettes a cancer hazard – that the first definitive scientific proof of the causal mechanism linking smoking to lung cancer was published. Decades before that proof, the US Surgeon General acted on the basis of evidence from animal experiments, statistical associations, and toxicology results that demonstrated consistent patterns (not absolute proof). As well-known local scientist Sandra Steingraber concludes in her book Living Downstream: for 32 years, the public was “protected from a now-proven danger by those who had the courage to act on partial evidence” (p. xxii). Finally, this statement is highly tailored by focusing only on artificial turf risks associated with crumb rubber while excluding those associated with nanoplastics, microplastics, and thermal risks, among others. It is problematic that the informational letter fails to acknowledge the many studies raising significant concerns about health effects of crumb rubber across these multiple factors. CONCLUSION There are a number of other claims presented in the Haley & Aldrich letter that call for deeper analysis. I trust that other public commenters will speak to those issues. Here, I will simply note that I have concerns about the methodological soundness of studies cited by Haley & Aldrich; and the problematic framing of statements implying that synthetic turf fields are nearly universally accepted, when in fact there is active policy debate in many countries and many bodies do prohibit the use of artificial turf. As a separate note, Cornell should make a decision now about whether they plan to use either recycled crumb rubber or virgin synthetic rubber for infill, given that these require different analyses (p. 24, Haley & Aldrich packet). I am disappointed that Cornell's understanding of artificial turf is so heavily reliant on industry viewpoints rather than a broad overview of the peer-reviewed scientific literature. If Cornell is acting in good faith and wants to understand the health and ecological impacts of artificial turf, they should ask scientists for a review instead of a consulting firm that has worked for BP. I urge the Town Planning Board to (1) issue a positive declaration on environmental review, and (2) not to grant what Cornell calls a “tiny change” for segmentation. These projects are not independent, because Cornell’s decisions about siting of turf fields at one site impact other sites. Namely, if Cornell decides the field hockey field will be converted at Tower Road, then it will require siting elsewhere on Game Farm Road. This is a unified issue and we would all benefit from treating it as such. Thank you kindly for your attention and consideration. Sincerely, bethany ojalehto mays FOR MORE RESEARCH ON ARTIFICIAL TURF: Sierra Club Loma Prieta. Public Health Risks of Artificial Turf. Submitted to the President Ellenberg and Santa Clara County Board of Supervisors. November 29, 2023. De Haan, William P., Rocío Quintana, César Vilas, Andrés Cózar, Miquel Canals, Oriol Uviedo, and Anna Sanchez-Vidal. The Dark Side of Artificial Greening: Plastic Turfs as Widespread Pollutants of Aquatic Environments. Environmental Pollution 334 (2023): 122094. Persellin, Ketura. New Studies Show PFAS in Artificial Grass Blades and Backing. Environmental Working Group. October 29, 2019. Barnes, M. R., & Watkins, E. (2023). “Nothing Beats Nature”: Park Visitor Preferences for Natural Turfgrass and Artificial Turf: A Case Study. HortScience, 58(4), 453-45. https://journals.ashs.org/hortsci/view/journals/hortsci/58/4/article-p453.xml Kalam Khandoker, T., Yusufzai, A. O., Ahmad, S., & Stephen, H. Artificial Turf on Urban Landscapes: An Overview. In World Environmental and Water Resources Congress 2023 (pp. 740-754). Liu, Z., & Jim, C. Y. (2021). Playing on natural or artificial turf sports field? Assessing heat stress of children, young athletes, and adults in Hong Kong. Sustainable Cities and Society, 75, 103271. Jim, C. Y. (2017). Intense summer heat fluxes in artificial turf harm people and environment. Landscape and Urban Planning, 157, 561-576. https://ceh.org/latest/press-releases/new-testing-reveals-high-levels-of-toxic-pfas-in-artificial- turf/ APPENDIX A: PARTIAL SELECTION OF STUDIES CITING BLEYER & KEEGAN 2018 This selection of studies illustrates how an unbiased scientific review would treat competing sources of evidence, in contrast to the one-dimensional report provided by Haley & Aldrich. How circular is your tyre: Experiences with extended producer responsibility from a circular economy perspective: "Despite this apparent success, there has been a recent backlash against recycled rubber and the EPR system in response to public concerns over the human and environmental health impacts of artificial sports fields made with recycled rubber granulate (Zembla, 2016). This led to a government inquiry on the topic and a series of reports were commissioned. In line with recent academic research (Bleyer and Keegan, 2018; Peterson et al., 2018), and evaluations of the European Chemicals Agency (ECHA, 2017), the Dutch government report on human health has found no evidence of cancer risks related to artificial turf fields made with recycled rubber (RIVM, 2017). However, other government reports evidenced important environmental impacts, especially for aquatic life (STOWA, 2018; Verschoor et al., 2018). This demonstrates the complexities of a circular system, which aim to narrow, slow, shrink, and close material cycles, but do so in ways that do not affect human and environmental health. This is often complicated, especially when dealing with complex recycling processes and materials containing a mixture of often unknown or toxic chemicals. This complexity poses the main obstacle to tyre management in the Netherlands . Health impacts of artificial turf: Toxicity studies, challenges, and future directions: “In 2014, a professional soccer coach released anecdotal evidence to suggest that artificial turf exposure could be causing cancer in soccer players, particularly goalies, causing a media frenzy on artificial turf and cancer risk (Bleyer, 2017). Although multiple athletes and coaches have blamed crumb rubber on incidents of cancer, the human epidemiology evidence for an association is scant and preliminary. In response to the soccer coach's claims, an investigation of incidences of cancer among skilled female college soccer players in Washington compared to other residents of the state found no significant association (Washington State Department of Health, 2017). However, this study was limited to a single university and did not include most female soccer players in the state. An investigation of the association between turf field density and incidences of cancer in counties in California also found no significant association (Bleyer and Keegan, 2018). A 2022 simulation of cancer risk in children due to PAH exposure from rubber playground surfaces estimated a ten times higher risk compared to soil surfaces (Tarafdar et al., 2020). No human epidemiology studies on artificial turf or crumb rubber have investigated any endpoints other than cancer. Skoczyńska, E., Leonards, P. E., Llompart, M., & De Boer, J. (2021). Analysis of recycled rubber: Development of an analytical method and determination of polycyclic aromatic hydrocarbons and heterocyclic aromatic compounds in rubber matrices. Chemosphere, 276, 130076. Recycled crumb rubber (CR) is rich in compounds with unrecognized toxic potency; Mats purchased in Dutch shops exceed the EU limits for articles placed on the market for use by the public. The obtained results stress the need for expanding the list of target compounds analyzed in crumb rubber." Most of the studies investigating the composition of CR, or the chemicals available for exposure through release into air or water, concentrate only on “standard” pollutants like heavy metals, PAHs confined to the 16 EPA-PAHs (US Environmental Protection Agency) or 8 carcinogenic PAHs (as defined in entry 50 to Annex XVII to REACH (European Chemicals Agency, 2012)), phthalates, bisphenol-A and benzothiazole (BTZ). CR research generally does not include compounds belonging to the group of additives and vulcanization agents. Vulcanization accelerators, like inter alia 2-methylthiobenzothiazole and 2-morpholinobenzothiazole, benzothiophene, dibenzothiophenes and other sulfur containing PAHs (PASHs), have been detected in urban runoff (Hüffer et al., 2019; Kumata et al., 2002; Zeng et al., 2004) but were not analyzed in CR. Also other rubber-specific compounds like sulfenamides (Ema et al., 2007), aromatic amines (Bolognesi and Moretto, 2014) and other toxic rubber additives have until now not been listed among the target organic compounds analyzed in CR. Recently, Schneider et al. (2020) analyzed a group of substances suggested by tire manufacturers based on sector-specific knowledge” and Celeiro et al. (2020) analyzed a large group of plasticizers, antioxidants and vulcanization agents in CR. Previously, Perkins et al. (2019) reported 306 chemicals identified in CR, from which 197 met the carcinogenicity criteria set in their computational toxicology analysis…The obtained results stress the need for expanding the list of target compounds analyzed in crumb rubber. APPENDIX B STUDIES REPORTING HEALTH RISKS FROM CRUMB RUBBER ARTIFICIAL TURF Graça, C. A., Rocha, F., Gomes, F. O., Rocha, M. R., Homem, V., Alves, A., & Ratola, N. (2022). Presence of metals and metalloids in crumb rubber used as infill of worldwide synthetic turf pitches: Exposure and risk assessment. Chemosphere, 299, 134379. “A multi-pathway human exposure study was also performed, and the risk assessment shows non-carcinogenic and carcinogenic risks from accidental crumb rubber ingestion (with Cr and Pb as major contributors) above the acceptable values for all the receptors except adult bystanders, with a higher significance to younger individuals. These results bring a different perspective regarding most of the studies reporting low risks related with exposure to metals in crumb rubber.” Skoczyńska, E., Leonards, P. E., Llompart, M., & De Boer, J. (2021). Analysis of recycled rubber: Development of an analytical method and determination of polycyclic aromatic hydrocarbons and heterocyclic aromatic compounds in rubber matrices. Chemosphere, 276, 130076. “Recycled crumb rubber (CR) is rich in compounds with unrecognized toxic potency; Mats purchased in Dutch shops exceed the EU limits for articles placed on the market for use by the public. The obtained results stress the need for expanding the list of target compounds analyzed in crumb rubber." Health impacts of artificial turf: Toxicity studies, challenges, and future directions Many communities around the country are undergoing contentious battles over the installation of artificial turf. Opponents are concerned about exposure to hazardous chemicals leaching from the crumb rubber cushioning fill made of recycled tires, the plastic carpet, and other synthetic components. Numerous studies have shown that chemicals identified in artificial turf, including polycyclic aromatic hydrocarbons (PAHs), phthalates, and per- and polyfluoroalkyl substances (PFAS), are known carcinogens, neurotoxicants, mutagens, and endocrine disruptors. However, few studies have looked directly at health outcomes of exposure to these chemicals in the context of artificial turf. Ecotoxicology studies in invertebrates exposed to crumb rubber have identified risks to organisms whose habitats have been contaminated by artificial turf. Chicken eggs injected with crumb rubber leachate also showed impaired development and endocrine disruption. The only human epidemiology studies conducted related to artificial turf have been highly limited in design, focusing on cancer incidence. In addition, government agencies have begun their own risk assessment studies to aid community decisions. Additional studies in in vitro and in vivo translational models, ecotoxicological systems, and human epidemiology are strongly needed to consider exposure from both field use and runoff, components other than crumb rubber, sensitive windows of development, and additional physiological endpoints. Identification of potential health effects from exposures due to spending time at artificial turf fields and adjacent environments that may be contaminated by runoff will aid in risk assessment and community decision making on the use of artificial turf. Attachment 2 – 5-21-24 PB Minutes Spoken Comment to the Town Planning Board Regarding Cornell’s proposal for Meinig Field House May 21, 2024 This issue matters a lot to our earth and our children, the stakes are high, and I value your time. I know you know that the decisions made here will have consequences for generations to come. I’m bethany ojalehto mays. I am a mother and a citizen of Ithaca, like you. Thanks for serving on this Board. I have a PhD in Psychology, specializing in environmental decision-making, and worked as an Assistant Professor of Human Development at Cornell before leaving to engage more directly with the climate crisis. 41 I submitted a written comment where I noted that Cornell’s information letter claims to provide a “scientific review” on the impacts of artificial turf but is unscientific. But you can read about those scientific points in my written comment. I’d like to speak to common sense dimensions of this problem, problems which the artificial turf industry concedes. Everyone in this room agrees on these points. You don’t need to read a single scientific article to appreciate these four big picture concerns: 1) Artificial turf is a petroleum-based product. It comes from fossil fuels. I don’t need to state the obvious: fossil fuels are imperiling life on this planet. We are all trying to reduce fossil fuel use. Why would Cornell knowingly give millions of dollars to the fossil fuel industry to pump more fossil fuels out of the ground, transform them into plastics through highly toxic manufacturing plants, and truck them to Ithaca using yet more fossil fuels? When they have beautiful grass fields already. 2) Artificial turf is plastic. New York State is working hard to eliminate plastics. We banned plastic bags. Now we are working to pass legislation reducing plastic packaging because “As long as the legislature fails to act, plastic polluters will continue harming our health, climate, and environment on the backs of the everyday taxpayers demanding progress.” said Judith Enck, president of Beyond Plastics and former U.S. Environmental Protection Agency regional administrator.. At this very moment, Cornell has a “Beyond Waste” campaign claiming to reduce plastics on campus. If all of us are working so hard to reduce plastic, then why on earth would Cornell convert several beautiful grass fields by paving them with…plastic? 3) Artificial turf is a carbon emissions problem. Organic grass turf is alive: it absorbs CO2 and releases oxygen, making it a carbon sink. Artificial turf is dead fossil fuels: it releases methane and CO2 while trapping heat, and then ends up in a landfill generating more climate-change causing emissions for decades to come. Why does Cornell want to increase their carbon emissions with artificial turf, rather than nurturing carbon sinks with organic grass lawns? Are they going to factor in all these increased emissions to their campus footprint and climate action plan? 4) The artificial turf industry concedes that their turfs shed a huge volume of material into the environment. Haley & Aldrich’s letter notes this but rather than acknowledging pollution is a problem, they claim that it’s no big deal because the heavy metals and toxins present in those materials “won’t leach into the environment at hazardous levels.” That claim is misleading. But even if it were accurate – even if the materials were biologically unavailable and all the toxins stayed in the materials where they “belonged” – since when is it okay to release 1-5 tons of infill waste into the environment – per field – every year – and claim that’s fine? That’s an average of 20 tons every 8 years per field (32:11). Seriously? We get fined if we throw one plastic water bottle along the side of the road. But Big Oil could be allowed to release many tons of plastic and infill materials every year into Ithaca’s soil and water, and that pollution is “no problem?” a) I don’t want little bits of artificial turf and tire crumb in my drinking water, no matter how “safe” the industry claims it is. Do you? To close, I request that you grant a positive environmental declaration, and that you do not grant what Cornell calls a “tiny change” for segmentation. These projects are not independent, because Cornell’s decisions about siting of turf fields at one site impact other sites. This is a unified issue and we would all benefit to treat it as such. I appreciate that the decisions we are being asked to make today will have tremendous consequences for the beings who live here for generations to come. I hope Cornell cares as deeply about our climate and our health as we do. ATTACHMENT 1 - PB minutes 5-21-24 Written comments submitted to the Ithaca Town Planning Board Regarding Cornell's proposal for Meinig Field House May 21, 2024 bethany ojalehto mays Dear Town Planning Board Members; I am a mother and citizen of Ithaca. I have a PhD in Psychology specializing in environmental decision-making,and worked as an Assistant Professor of Human Development at Cornell before leaving to engage more directly with the climate crisis. Thank you for serving on this Board,and thank you for considering this written comment. Responding to the climate crisis requires wise decision-making for future generations.You are on the frontlines.As a Planning Board,the decisions you make will transform the composition of our soil,land,water,and determine carbon emissions for years to come. It is not an exaggeration to say that our fate lies partly in your hands. I offer this comment with gratitude to you for taking on this responsibility. There are significant climate concerns about Cornell's proposed Meinig Field House and artificial turf fields. I will address those concerns in other spoken and written comments. For today's comment, I want to focus on Cornell's evaluation of the health and environmental impacts of artificial turf specifically. In their Meinig Field House Packet, Cornell included an"informational letter"from the consulting firm Haley&Aldrich that claimed to provide a summary of research on the health and ecological impacts of artificial turf. It was not a scientific review,but a one-sided report that relied heavily on industry reports that were not peer-reviewed scientific articles (as implied) and contained a number of concerning misunderstandings.Those points are detailed below,but first I want to speak to the dimensions of debate. THE DIMENSIONS OF THE"DEBATE" Planning Boards are often presented with what appear to be two sides of a debate: one from industry and one from concerned citizens and scientists.We can step back and ask: who benefits from each narrative in this debate?The artificial turf industry has the goal of maximizing their profits;they present evidence that artificial turf is safe. Concerned citizens and scientists have the goal of maximizing the common good; they present evidence that artificial turf has significant health and ecological harms. How do we weigh these two narratives? Artificial turf companies are businesses. Haley&Aldrich is a business.They are hired by companies to compile research reviews that will help those firms make more money. We have no reason to expect that the artificial turf industry sees a transparent or precautionary approach to health, ecological,and climate impacts of artificial turf as benefiting their bottom line.Any research review from industry should be interpreted with a precautionary awareness that the review may be biased toward their own profit. I join many others in speaking up as a concerned citizen and scientist. I offer this research and public comment as a volunteer. I make no money from this work. I have nothing at stake personally, except how much I care about stewarding lands,waters,and ecosystems that support wellbeing for all living beings.Thus,any research review that you receive from me may be"biased:" I am biased towards a precautionary principle to protecting human and ecological health from irreversible consequences,and I am biased toward actions and decisions that will preserve a habitable planet. Not all debates are genuine,and not all information is equal. Some information is designed to make more money for fossil fuels.That should be called out as disinformation,as the recent US Congressional Report on Big Oil's disinformation highlights. Big Oil has undertaken a decades-long campaign designed to skew our understanding of the climate costs of fossil fuels,often through misinformation masked as"science."Artificial turf is part of Big Oil: it is a fossil fuel product.As outlined below, I respectfully offer that Cornell's current campaign to present artificial turf as safe and harmless is another instance of Big Oil's misinformation masked as"science." I have heard it said that concerned citizens and scientists are biased because they are"advocates" for the common good.That's accurate as far as it goes,but it doesn't go far enough.We must also acknowledge that industry is biased:they are advocates for their own profit. Everyone is biased because everyone has a perspective.Just as it is impossible to take a photograph without adopting a perspective,it is impossible to ask a question and find an answer without introducing a perspective: and that includes scientists.With that in mind,we should acknowledge that every research project and every building proposal is biased because it introduces a perspective.The question is: is it biased toward the common good? There are many cases in which it is smart to be biased. For instance,it is smart to be biased toward survival. I hope our Town Planning Board is biased toward protecting a habitable ecosystem where all of us can survive and thrive. On that note, I highly recommend that Town Planning Board members watch the expert panel of scientists and advocates who presented on artificial and natural turf at Zero Waste Ithaca's recent webinar,and read the 2023 Sierra Club's Public Health Risks of Artificial Turfs submitted to the Santa Clara County Board of Supervisors. It reflects many of the same problems which I now turn to outline with the Haley&Aldrich research review below. MISINFORMATION: The information letter by Haley&Aldrich is not sound science I was disappointed to see Cornell's information letter from Haley&Aldrich.The letter claims to provide a"summary of recently published studies and reports that evaluate the safety(health and environmental risks) of using synthetic turf athletic fields." Instead,it presents exclusively pro- industry research findings to the exclusion of the rest of the peer-reviewed scientific literature.This one-sided summary of research is designed to be comforting rather than informative. I list significant problems and questions below. (1) The letter is transparently pro-industry. Despite its claim to "summarize"the evidence,the letter does not provide a balanced summary of the evidence or evaluation of competing findings,as you would expect from any scientific review (see appendix). It does not review any of the research showing negative health and ecological impacts of artificial turf.As a basic measure of scientific rigor,one would expect a review to survey the relevant literature,address conflicting findings,and evaluate their merits,rather than presenting a cherry-picked selection of studies that say only one thing. (2) The letter contradicts its own standard of evidence.After pointing out the need to rely on peer reviewed scientific literature and claiming that"peer reviewed scientific studies were used to support the conclusions developed in this memorandum,"the authors of the letter then go on to contradict their own advice by relying heavily on two industry reports that were not peer-reviewed scientific articles,and a set of test results from Labosport that are not peer-reviewed. (3) Industry reports are presented on par with peer-reviewed scientific research. The letter approvingly cites reports authored by consulting firms and industry(TetraTech,TRC Companies) and treats them as reliable research,despite the fact that those reports were not peer-reviewed scientific articles.The report by TetraTech was reviewed by another consulting firm (the Horsley Witen Group),but this does not amount to peer-reviewed scientific research. Furthermore,the testing results presented from Labosport International are results from a single lab,not a scientific research program. Research conducted by and for the synthetic turf industry should not be considered on par with peer-reviewed scientific articles,in part because industry has a profit motive in undertaking research. (4) The informational letter does not address the climate costs of artificial turf. Natural grass fields absorb CO2 and produce oxygen,whereas artificial turf fields do exactly the opposite, emitting CO2, methane,and other greenhouse gases.Any institution that claims to care about carbon emissions should not be replacing natural grass fields with artificial turf fields that will intensify emissions while polluting the environment for decades to come.This is exactly the kind of land use pattern and resource consumption that is destroying our climate and our ecosystems,pushing us past multiple planetary boundaries at once. (5) The informational letter presents arguments based on background contamination that is not credible. The informational letter implies that PFAS found in artificial turf are unproblematic because the levels are"negligible"compared to background levels in soil: "Evaluation of the PFAS detected in the Tetratech (2021) and TRC (2022) studies [note: neither of which are peer-reviewed scientific articles] indicate that fewer PFAS compounds were detected in synthetic turf,and at lower concentrations,than those that are present as a background condition in soil." This is not a credible argument. It is simply wrong to argue that because the soil is already so contaminated,further contamination doesn't matter. First,this would only be the case if PFAS pollution followed a surprising nonlinear dose-response relationship where once you reached a certain level of pollution,nothing else above that mattered for the relevant outcome measures (health or environmental).That's not how pollution works.We have every reason to expect that more pollution will be more harmful,both for humans and the environment. Second,this argument is circular,and it is designed to deny accountability for both past and future pollution. Current levels of background soil contamination are so high precisely because the industry hasn't been regulated.Aldrich&Haley appear to see that as evidence for why industry shouldn't be regulated going forward. Quite the opposite. High levels of contamination in soil and water provide urgent evidence for the need to start regulating industry now. (6) The report contains a recycling claim that requires further evidence: "During the field replacement process, the existing turf will be recycled."In a 2021 Massachusetts hearing,synturf industry industry representative Mark Curran admitted that not a single artificial turf field has been recycled to date. Likewise,the CEO of Re-Match Turf Recycling said in 2020 that"there is no synthetic turf recycling plant in America yet."A 2023 Beyond Plastics Report found that Exxon Mobil's claims to engage in"advanced chemical recycling"of plastic waste including artificial turf is toxic, unregulated,and unlikely to constitute recycling. If Cornell believes their artificial turf will be one of the first examples of successful recycling,then they should detail exactly what their plan is for "recycling"the turf,backing this up with transparent information on how and where the recycling will happen. (7) 1 have significant reservations and questions about the informational letter's presentation and interpretation of testing results for metals and toxins based in part on industry reports. First,all reported tests use screening levels for direct contact and protection of groundwater.These are not the relevant thresholds if you're concerned about ingestion or absorption of these materials into the human body(which have more stringent thresholds). Second,the informational letter presents findings that artificial turf contains many heavy metals and toxins,including lead and PFAS,but dismisses these as unlikely to cause harm because they are below the chosen screening levels.The truth is,no known level of exposure to lead or PFAS is safe. The EPA recently announced that no known levels of PFAS'forever chemicals'are safe,and the EPA sets the maximum contaminant level goals (MCLGs) for lead at zero: "EPA has set this level based on the best available science which shows there is no safe level of exposure to lead.The fact that there is no safe level of exposure underscores the fact that any action to reduce exposures can have impacts on lives and livelihoods."The Town and City Planning Boards have the opportunity to take action now to reduce exposures by saying no to artificial turf. Third,the informational letter acknowledges that some of the metals and toxins did in fact exceed screening limits for direct contact and/or protection of groundwater (including cobalt,zinc, benzo(a)pyrene,and aniline). However,they then argued that these are"not harmful"because the "EPA (2019) concluded that only 3%of the metal concentrations reported in the crumb rubber samples are available for exposure." Is it common practice to argue that the screening levels are not themselves useful,but should instead be transformed by an exposure factor?Without careful justification for this additional step,the reasoning appears post hoc. Screening levels for direct contact and groundwater contamination should be respected. (8) The report sets a deceptively high bar for proof of risk combined with highly tailored language- exactly as Big Tobacco did for decades. The informational letter states that over 100 peer-reviewed scientific studies have been conducted on health risks associated with crumb rubber turf fields,and then states: "We are not aware of any peer-reviewed scientific studies which draw an association between adverse health effects and use of crumb rubber." This statement is either inaccurate,intentionally misleading,or sets the wrong standard for proof. It is simply inaccurate to state that no study has reported significant health risks of tire crumb infill. Many empirical studies have highlighted risks based on toxicity results,potential accidental ingestion, ecotoxicology,animal experiments,and limited human epidemiology(see Appendix B). Assuming the consultants are aware of these studies,their statement can only be interpreted as setting a deceptively high bar for proof of risk. It is exceptionally hard to demonstrate a significant association between a specific toxin and adverse health effects in humans (and it may require that people actively suffer the consequences in order to be studied).That does not invalidate the many other data sources that can and should be used to assess potential health risks of artificial turf,as cited above. The consultants appear to be replicating a strategy that Big Tobacco employed for decades. First, they ask us to assume that artificial turf is safe until proven otherwise.There is strong evidence to assume that it's unsafe until proven otherwise-but the industry has shifted the burden of proof onto the public while their product continues to generate profit. Second, Haley&Aldrich present a deceptively high bar for proof of health risks. For decades, Big Tobacco sowed doubt about the conclusiveness of links between smoking and cancer,arguing that there was no"causal proof'for the association.They were right,but their standard of evidence was dead wrong. It was only in 1996 - 32 years after the US Surgeon General declared cigarettes a cancer hazard-that the first definitive scientific proof of the causal mechanism linking smoking to lung cancer was published. Decades before that proof,the US Surgeon General acted on the basis of evidence from animal experiments,statistical associations,and toxicology results that demonstrated consistent patterns (not absolute proof).As well-known local scientist Sandra Steingraber concludes in her book Living Downstream: for 32 years,the public was"protected from a now-proven danger by those who had the courage to act on partial evidence" (p.xxii). Finally,this statement is highly tailored by focusing only on artificial turf risks associated with crumb rubber while excluding those associated with nanoplastics,microplastics,and thermal risks, among others. It is problematic that the informational letter fails to acknowledge the many studies raising significant concerns about health effects of crumb rubber across these multiple factors. CONCLUSION There are a number of other claims presented in the Haley&Aldrich letter that call for deeper analysis. I trust that other public commenters will speak to those issues.Here,I will simply note that I have concerns about the methodological soundness of studies cited by Haley&Aldrich; and the problematic framing of statements implying that synthetic turf fields are nearly universally accepted,when in fact there is active policy debate in many countries and many bodies do prohibit the use of artificial turf. As a separate note, Cornell should make a decision now about whether they plan to use either recycled crumb rubber or virgin synthetic rubber for infill,given that these require different analyses (p. 24, Haley&Aldrich packet). I am disappointed that Cornell's understanding of artificial turf is so heavily reliant on industry viewpoints rather than a broad overview of the peer-reviewed scientific literature.If Cornell is acting in good faith and wants to understand the health and ecological impacts of artificial turf,they should ask scientists for a review instead of a consulting firm that has worked for BP. I urge the Town Planning Board to (1) issue a positive declaration on environmental review,and (2) not to grant what Cornell calls a"tiny change"for segmentation.These projects are not independent,because Cornell's decisions about siting of turf fields at one site impact other sites. Namely,if Cornell decides the field hockey field will be converted at Tower Road,then it will require siting elsewhere on Game Farm Road.This is a unified issue and we would all benefit from treating it as such. Thank you kindly for your attention and consideration. Sincerely, Bethany ojalehto mays FOR MORE RESEARCH ON ARTIFICIAL TURF: Sierra Club Loma Prieta. Public Health Risks of Artificial Turf.Submitted to the President Ellenberg and Santa Clara County Board of Supervisors.November 29,2023. De Haan,William P., Rocio Quintana, Cesar Vilas,Andres C6zar, Miquel Canals, Oriol Uviedo,and Anna Sanchez-Vidal.The Dark Side of Artificial Greening: Plastic Turfs as Widespread Pollutants of Aquatic Environments. Environmental Pollution 334 (2023): 122094. Persellin, Ketura. New Studies Show PFAS in Artificial Grass Blades and Backing. Environmental Working Group. October 29, 2019. Barnes, M.R.,&Watkins,E. (2023)."Nothing Beats Nature": Park Visitor Preferences for Natural Turfgrass and Artificial Turf:A Case Study. HortScience, 58(4),45345. https://journals.ashs.org/hortsci/view[journals/hortsci/58/4/article-p453.xml Kalam Khandoker,T.,Yusufzai,A. 0.,Ahmad,S.,&Stephen, H.Artificial Turf on Urban Landscapes: An Overview.In World Environmental and Water Resources Congress 2023 (pp. 740-754). Liu,Z.,&Jim, C.Y. (2021). Playing on natural or artificial turf sports field?Assessing heat stress of children,young athletes,and adults in Hong Kong,Sustainable Cities and Society, 75, 103271. Jim, C.Y. (2017). Intense summer heat fluxes in artificial turf harm people and environment. Landscape and Urban Planning, 157, 561-576. https://ceh.org/latest/press-releases/new-testing-reveals-high-levels-of-toxic-pfas-in-artificial- turf/ APPENDIX A: PARTIAL SELECTION OF STUDIES CITING BLEYER&KEEGAN 2018 This selection of studies illustrates how an unbiased scientific review would treat competing sources of evidence,in contrast to the one-dimensional report provided by Haley&Aldrich. How circular is your tyre: periences with extended producer responsibility from a circular economy perspective: "Despite this apparent success,there has been a recent backlash against recycled rubber and the EPR system in response to public concerns over the human and environmental health impacts of artificial sports fields made with recycled rubber granulate (Zembla,2016).This led to a government inquiry on the topic and a series of reports were commissioned. In line with recent academic research (Bleyer and Keegan,2018; Peterson et al., 2018),and evaluations of the European Chemicals Agency(ECHA, 2017),the Dutch government report on human health has found no evidence of cancer risks related to artificial turf fields made with recycled rubber(RIVM. 2017).However,other government reports evidenced important environmental impacts,especially for aquatic life (STOWA, 2018;Verschoor et al., 2018).This demonstrates the complexities of a circular system,which aim to narrow,slow,shrink,and close material cycles,but do so in ways that do not affect human and environmental health.This is often complicated,especially when dealing with complex recycling processes and materials containing a mixture of often unknown or toxic chemicals.This complexity poses the main obstacle to tyre management in the Netherlands. Health impacts of artificial turf: Toxicity studies,challenges,and future directions: "In 2014,a professional soccer coach released anecdotal evidence to suggest that artificial turf exposure could be causing cancer in soccer players,particularly goalies,causing a media frenzy on artificial turf and cancer risk(Bleyer, 2017).Although multiple athletes and coaches have blamed crumb rubber on incidents of cancer,the human epidemiology evidence for an association is scant and preliminary.In response to the soccer coach's claims,an investigation of incidences of cancer among skilled female college soccer players in Washington compared to other residents of the state found no significant association (Washington State Department of Health, 2017).However,this study was limited to a single university and did not include most female soccer players in the state. An investigation of the association between turf field density and incidences of cancer in counties in California also found no significant association (Bleyer and Keegan, 2018).A 2022 simulation of cancer risk in children due to PAH exposure from rubber playground surfaces estimated a ten times higher risk compared to soil surfaces (Tarafdar et al., 2020). No human epidemiology studies on artificial turf or crumb rubber have investigated any endpoints other than cancer. Skoczynska,E., Leonards, P. E., Llompart, M.,&De Boer,J. (2021).Analysis of recycled rubber: Development of an analytical method and determination of polyvclic aromatic hydrocarbons and heterocyclic aromatic compounds in rubber matrices. Chemosphere, 276, 130076. Recycled crumb rubber(CR) is rich in compounds with unrecognized toxic potency; Mats purchased in Dutch shops exceed the EU limits for articles placed on the market for use by the public.The obtained results stress the need for expanding the list of target compounds analyzed in crumb rubber." Most of the studies investigating the composition of CR,or the chemicals available for exposure through release into air or water,concentrate only on"standard"pollutants like heavy metals, PAHs confined to the 16 EPA-PAHs (US Environmental Protection Agency) or 8 carcinogenic PAHs (as defined in entry 50 to Annex XVII to REACH (European Chemicals Agency, 2012)), phthalates,bisphenol-A and benzothiazole (BTZ). CR research generally does not include compounds belonging to the group of additives and vulcanization agents.Vulcanization accelerators,like inter alia 2-methylthiobenzothiazole and 2-morpholinobenzothiazole, benzothiophene,dibenzothiophenes and other sulfur containing PAHs (PASHs),have been detected in urban runoff(Huffer et al., 2019; Kumata et al., 2002; Zeng et al., 2004) but were not analyzed in CR.Also other rubber-specific compounds like sulfenamides (Ema et al., 2007),aromatic amines (Bolognese and Moretto, 2014) and other toxic rubber additives have until now not been listed among the target organic compounds analyzed in CR.Recently,Schneider et al. (2020) analyzed a group of substances suggested by tire manufacturers based on sector-specific knowledge"and Celeiro et al. (2020) analyzed a large group of plasticizers,antioxidants and vulcanization agents in CR. Previously, Perkins et al. (2019) reported 306 chemicals identified in CR,from which 197 met the carcinogenicity criteria set in their computational toxicology analysis...The obtained results stress the need for expanding the list of target compounds analyzed in crumb rubber. APPENDIX B STUDIES REPORTING HEALTH RISKS FROM CRUMB RUBBER ARTIFICIAL TURF Grata, C.A., Rocha, F., Gomes, F. 0., Rocha, M. R., Homem,V.,Alves,A.,&Ratola, N. (2022). Presence of metals and metalloids in crumb rubber used as infill of worldwide synthetic turf pitches: Exposure and risk assessment. Chemosphere, 299, 134379. "A multi-pathway human exposure study was also performed,and the risk assessment shows non-carcinogenic and carcinogenic risks from accidental crumb rubber ingestion (with Cr and Pb as major contributors) above the acceptable values for all the receptors except adult bystanders,with a higher significance to younger individuals.These results bring a different perspective regarding most of the studies reporting low risks related with exposure to metals in crumb rubber." Skoczynska,E., Leonards, P. E., Llompart, M.,&De Boer,J. (2021).Analysis of recycled rubber: Development of an analytical method and determination of polyvclic aromatic hydrocarbons and heterocyclic aromatic compounds in rubber matrices. Chemosphere, 276, 130076. "Recycled crumb rubber(CR) is rich in compounds with unrecognized toxic potency; Mats purchased in Dutch shops exceed the EU limits for articles placed on the market for use by the public.The obtained results stress the need for expanding the list of target compounds analyzed in crumb rubber." Health impacts of artificial turf: Toxicity studies, challenges,and future directions Many communities around the country are undergoing contentious battles over the installation of artificial turf. Opponents are concerned about exposure to hazardous chemicals leaching from the crumb rubber cushioning fill made of recycled tires,the plastic carpet,and other synthetic components. Numerous studies have shown that chemicals identified in artificial turf,including polycyclic aromatic hydrocarbons (PAHs),phthalates,and per-and polyfluoroalkyl substances (PFAS),are known carcinogens,neurotoxicants,mutagens,and endocrine disruptors.However,few studies have looked directly at health outcomes of exposure to these chemicals in the context of artificial turf. Ecotoxicology studies in invertebrates exposed to crumb rubber have identified risks to organisms whose habitats have been contaminated by artificial turf. Chicken eggs injected with crumb rubber leachate also showed impaired development and endocrine disruption.The only human epidemiology studies conducted related to artificial turf have been highly limited in design, focusing on cancer incidence.In addition,government agencies have begun their own risk assessment studies to aid community decisions.Additional studies in in vitro and in vivo translational models,ecotoxicological systems,and human epidemiology are strongly needed to consider exposure from both field use and runoff,components other than crumb rubber,sensitive windows of development,and additional physiological endpoints. Identification of potential health effects from exposures due to spending time at artificial turf fields and adjacent environments that may be contaminated by runoff will aid in risk assessment and community decision making on the use of artificial turf. Attachment 2 — 5-21-24 PB Minutes Spoken Comment to the Town Planning Board Regarding Cornell's proposal for Meinig Field House May 21, 2024 This issue matters a lot to our earth and our children,the stakes are high,and I value your time. I know you know that the decisions made here will have consequences for generations to come. I'm bethany ojalehto mays. I am a mother and a citizen of Ithaca,like you.Thanks for serving on this Board. I have a PhD in Psychology,specializing in environmental decision-making,and worked as an Assistant Professor of Human Development at Cornell before leaving to engage more directly with the climate crisis.41 I submitted a written comment where I noted that Cornell's information letter claims to provide a "scientific review"on the impacts of artificial turf but is unscientific. But you can read about those scientific points in my written comment. I'd like to speak to common sense dimensions of this problem,problems which the artificial turf industry concedes. Everyone in this room agrees on these points.You don't need to read a single scientific article to appreciate these four big picture concerns: 1) Artificial turf is a petroleum-based product. It comes from fossil fuels. I don't need to state the obvious: fossil fuels are imperiling life on this planet.We are all trying to reduce fossil fuel use.Why would Cornell knowingly give millions of dollars to the fossil fuel industry to pump more fossil fuels out of the ground,transform them into plastics through highly toxic manufacturing plants,and truck them to Ithaca using yet more fossil fuels?When they have beautiful grass fields already. 2) Artificial turf is plastic. New York State is working hard to eliminate plastics.We banned plastic bags. Now we are working to pass legislation reducing plastic packaging because"As long as the legislature fails to act,plastic polluters will continue harming our health,climate, and environment on the backs of the everyday taxpayers demanding progress."said Judith Enck,president of Beyond Plastics and former U.S. Environmental Protection Agency regional administrator..At this very moment, Cornell has a"Beyond Waste"campaign claiming to reduce plastics on campus. If all of us are working so hard to reduce plastic,then why on earth would Cornell convert several beautiful grass fields by paving them with...plastic? 3) Artificial turf is a carbon emissions problem. Organic grass turf is alive: it absorbs CO2 and releases oxygen,making it a carbon sink.Artificial turf is dead fossil fuels: it releases methane and CO2 while trapping heat,and then ends up in a landfill generating more climate-change causing emissions for decades to come.Why does Cornell want to increase their carbon emissions with artificial turf,rather than nurturing carbon sinks with organic grass lawns?Are they going to factor in all these increased emissions to their campus footprint and climate action plan? 4) The artificial turf industry concedes that their turfs shed a huge volume of material into the environment. Haley&Aldrich's letter notes this but rather than acknowledging pollution is a problem,they claim that it's no big deal because the heavy metals and toxins present in those materials"won't leach into the environment at hazardous levels."That claim is misleading. But even if it were accurate-even if the materials were biologically unavailable and all the toxins stayed in the materials where they"belonged"-since when is it okay to release 1-5 tons of infill waste into the environment-per field-every year-and claim that's fine?That's an average of 20 tons every 8 years field (32:11). Seriously?We get fined if we throw one plastic water bottle along the side of the road. But Big Oil could be allowed to release many tons of plastic and infill materials every year into Ithaca's soil and water,and that pollution is"no problem?" a) I don't want little bits of artificial turf and tire crumb in my drinking water,no matter how"safe"the industry claims it is. Do you? To close, I request that you grant a positive environmental declaration,and that you do not grant what Cornell calls a"tiny change"for segmentation.These projects are not independent,because Cornell's decisions about siting of turf fields at one site impact other sites.This is a unified issue and we would all benefit to treat it as such. I appreciate that the decisions we are being asked to make today will have tremendous consequences for the beings who live here for generations to come. I hope Cornell cares as deeply about our climate and our health as we do.