HomeMy WebLinkAboutPB Packet 2024-05-07
TOWN OF ITHACA PLANNING BOARD
Shirley A. Raffensperger Board Room, Town Hall
215 North Tioga Street
Ithaca, New York 14850
Tuesday, May 7, 2024 6:30 P.M.
Members of the public are welcome to attend in-person at Town Hall or virtually via Zoom. The public will
have an opportunity to see and hear the meeting live and provide comments in-person or through Zoom at
https://us06web.zoom.us/j/83643764382.
If the public would like to attend the meeting for viewing purposes only, it is recommended to watch the
livestream video on YouTube (https://www.youtube.com/channel/UCC9vycXkJ6klVIibjhCy7NQ/live).
AGENDA
1. PUBLIC HEARING: Consideration of Preliminary and Final Site Plan Approval for the Soil
Factory, a Project of Weave Community, located at 142 Ithaca Beer Drive within the Light
Industrial Zone and Inlet Valley Center Overlay District. The project involves establishing soil
research test gardens on the site, along with multi-disciplinary meeting, workshop, and event
spaces classified as Community Workshop and Place of Assembly uses in the existing buildings.
Site improvements include delineating bicycle, vehicle, pedestrian circulation, and parking areas.
There are no proposed exterior changes to the existing buildings. This is a Type II Action under the
State Environmental Quality Review Act and is not subject to environmental review. Greentree
Ithaca, LLC, Owner; Neil Schill, Applicant/Agent.
2. Persons to be heard.
3. Approval of Minutes.
4. Other Business.
5. Adjournment.
C.J. Randall
Director of Planning
607-273-1747
NOTE: IF ANY MEMBER OF THE PLANNING BOARD IS UNABLE TO ATTEND, PLEASE NOTIFY
CHRIS BALESTRA AT 607-273-1747 or CBALESTRA@TOWNITHACANY.GOV.
(A quorum of four (4) members is necessary to conduct Planning Board business.)
Accessing Meeting Materials Online
Site Plan and Subdivision applications and associated project materials are accessible electronically on the Town’s website at
https://townithacany.gov/meeting-calendar-agendas/ under the calendar meeting date.
TOWN OF ITHACA PLANNING BOARD
PUBLIC HEARING NOTICE
The Planning Board will hold a public hearing on Tuesday, May 7, 2024, starting at 6:30 P.M. on the following
matter:
Consideration of Preliminary and Final Site Plan Approval for the Soil Factory, a Project of Weave
Community, located at 142 Ithaca Beer Drive within the Light Industrial Zone and Inlet Valley Center
Overlay District. The project involves establishing soil research test gardens on the site, along with
multi-disciplinary meeting, workshop, and event spaces classified as Community Workshop and Place
of Assembly uses in the existing buildings. Site improvements include delineating bicycle, vehicle,
pedestrian circulation, and parking areas. There are no proposed exterior changes to the existing
buildings. This is a Type II Action under the State Environmental Quality Review Act and is not
subject to environmental review. Greentree Ithaca, LLC, Owner; Neil Schill, Applicant/Agent.
Members of the public are welcome to attend in-person at Town Hall or virtually via Zoom. The public will
have an opportunity to see and hear the meeting live and provide comments in-person or through Zoom at
https://us06web.zoom.us/j/83643764382.
If the public would like to attend the meeting for viewing purposes only, it is recommended to watch the
livestream video on YouTube (https://www.youtube.com/channel/UCC9vycXkJ6klVIibjhCy7NQ/live).
Any person wishing to address the board will be heard. In addition, comments can be sent via email to
townclerk@townithacany.gov up to the end of business the day of the meeting and all comments will be
forwarded to the board. Additional information is available at https://townithacany.gov/.
C.J. Randall, Director of Planning
1
PLANNING DEPARTMENT MEMORANDUM
TO: Planning Board Members
FROM: Christine Balestra, Senior Planner
DATE: April 30, 2024
RE: Soil Factory, 142 Ithaca Beer Drive – Preliminary and Final Site Plan Approval
Enclosed please find materials related to the consideration of Preliminary and Final Site Plan approval
for the proposed Soil Factory, a Project of Weave Community, located at 142 Ithaca Beer Drive within
the Light Industrial Zone and Inlet Valley Center Overlay District.
The project involves establishing soil research test gardens on the site, along with multi-disciplinary
meeting, workshop, and event spaces in the existing buildings. There are no proposed exterior changes
to the existing buildings. Site improvements include delineating bicycle, vehicle, pedestrian circulation,
and parking areas. The project, scheduled for consideration at the May 7, 2024, Planning Board meeting,
is permitted in the Inlet Valley Center Overlay District with site plan approval by the Planning Board.
Physical Site Characteristics & Property History
The two parcels associated with the project total approximately 2.79+/- acres and consist of three
existing structures (600+/- s.f. office, 6,000+/- s.f. warehouse, loading dock), paved areas, and open
field/lawn areas (see attached photos from a 4-24-2024 Planning staff site visit). The developed portion
of the project is generally flat with a gentle rise into the field to the west. There is an existing gravel
access road in front of the site located on an adjacent property. The gravel road (Ithaca Beer Drive) is
privately owned and maintained by the property owner of the Ithaca Beer Company. There are no
planned improvements or changes to the road in association with the project.
According to the Cornell Library Digital Collections of New York State Aerial Photographs
https://digital.library.cornell.edu/collections/aerialny, the existing structures on the project site were
constructed sometime between 1964 and the 1990. The entire area was utilized as farmland prior to
1964, and slowly developed into the light industrial area it is today. Based on a review of old area survey
maps, the parcels have existed in their current configuration since at least the early 1960’s. The Town of
Ithaca Planning Department does not have a record of a site plan approval for the existing structures, so
the former use of the structures is unknown.
The Planning Department archives include a former proposal (March 2017) to utilize the existing office
and warehouse building for manufacturing, storage, shipping, and retail farm product sales associated
with the Greentree Garden Center business, which ceased operations in May 2023. That sketch plan also
included a proposed 10,000+/- square foot expansion of the warehouse, with additional parking,
stormwater facilities, etc. The project never advanced beyond the sketch plan phase, and the property
owner has since leased the property to the applicant for the Soil Factory adaptive reuse.
2
Site Plan Elements (Parking, Landscaping, Lighting, etc.)
The properties are located within the Inlet Valley Overlay District (IVOD/IV-C), with Light Industrial as the
underlying zoning designation. The IVOD requires site plan approval for the uses of the property, which
have been classified as Community Workshop and Place of Assembly, as determined by Marty Moseley,
Director of Code Enforcement, in consultation with the Planning Department. The IVOD standards listed
in §270-171.6 (Design standards and guidelines, B. Applicability) do not apply because there is no
“development” proposed; the structures, access, and parking areas exist. The proposal includes
delineating parking, demarcating areas for pedestrian access and bicycle parking, adding signage, and
other minor site improvements. To that end, the attached site plan largely reflects what exists on the
property today.
Please note: the applicants’ narrative refers to a “change of use from S to F,” which is a NYS Building
Code reference related to occupancy changes inside a building. It is different from a change in use
relative to the Town Zoning Code or IVOD regulations. The application materials include a report from
Hallam ICS that supports the NYS Building Code change of use for this property. This report has been
included for Planning Board information only. The applicant is NOT requesting a use variance. The
proposed use of the property is governed under the Town Zoning Code and IVOD regulations, which
permits Community Workshop and Place of Assembly uses with site plan approval.
The site does not have any existing exterior lighting except for two small lights on the warehouse
building. Though this type of lighting may not comply with Town Code §173, Outdoor Lighting, the lights
could be considered a non-conforming site element (“grandfathered”), since they are pre-existing and
there are no changes proposed to the building.
The project does not include landscaping, but it may not be necessary given the proposed use of the
site, and the location of the property hidden behind the Elmira Road corridor and away from residential
and publicly viewable areas. However, the Planning Board may discuss any concerns related to lighting
and landscaping with the applicant at the meeting.
There appears to be adequate room for parking for all anticipated uses without impacting the gravel
road or any adjacent properties. According to the provisions of Town Code §270-227, Parking, the
project requires 22 parking spaces for the proposed uses, where the applicant is providing 20 parking
spaces (the site plan that was submitted contains a text box that lists 23 parking spaces, but there are only 20
parking spaces shown on the plan). Town Code §270-227 authorizes the Planning Board to grant up to a
20% reduction in the required number of parking spaces for a project. This project requires the board to
consider granting a 9% reduction. The same section of Town Code also gives the Planning Board the
authority to approve parking spaces that are smaller than the standard parking space size (standard size
= 180 square feet), and to allow parking in the front and side yards of the property. The proposal
includes 162 square foot parking spaces, located in the front yard of the property. The attached draft
resolution contains sections related to the reduction of parking spaces and sizes, and parking in the front
yard.
Environmental Review (SEQR)
The proposed project is classified as a Type II Action, pursuant to the State Environmental Quality
Review Act (6 NYCRR Section 617.5), because it involves a “replacement in kind” on the same site. There
is no construction, paving, or development proposed; the project is solely adaptive reuse of the existing
buildings with complementary minor site improvements. The Soil Factory project is not expected to
3
create significant environmental impacts, as it is located on an existing disturbed site with no significant
slopes, wetlands, streams, rare, threatened, or endangered plant or animal species or Unique Natural
Areas. Although there is a NYSE DEC Class C stream (indicated by DEC as having best use for fishing) just
to the south of the gravel road, there are no proposed changes to the road or the site. The site is located
away from residences and public areas, so adverse noise and lighting impacts are not anticipated. There
are no changes to existing drainage patterns, utilities, or infrastructure that would necessitate a
stormwater management plan.
The project site is very well hidden from NYS Route 13/Elmira Road and NYS Route 13A/Five Mile Drive.
Parking in the front yard is not expected to create significant aesthetic or traffic impacts, nor will
reducing the number or size of parking spaces for the project. The site plan shows parking well away
from a stream on an adjacent property to the south that also contains the gravel access road to the site.
The project does not include parking along, paving, or any other improvements to the gravel road.
Please feel free to contact me if you have questions regarding this proposal by phone at 273-1721 or by
email at cbalestra@townithacany.gov.
Att.
Cc: John Gaunt, Greentree Ithaca, LLC
Neil Schill
THE SOIL FACTORY a project of WEAVE COMMUNITY
at 142 Ithaca Beer Drive,Ithaca
The Soil Factory,a project of the nonprofit WEAVE Community,is an exercise in
facilitating the interchange of ideas,conversation,engagement,and experimentation,
between scientists,artists and community members.It was established in 2017,and is
funded primarily from research,local foundation and arts grants.
It has 1 part time staff member,and educates/engages several hundred students and
community members each year.We utilize the warehouse for research and
development as well as the adjacent field for outdoor study.
This preliminary site plan review supports our proposed change of use from S to F.We
submitted the permit for the change of use,and provided the support materials
requested.The Town reviewed our intended use against zoning requirements and the
inlet valley overlay see email (attachment ).As part of the Town's response we were
asked to submit a Preliminary Site Plan for review.
The following describes our activities and use of the site.It shows the layout of parking
and vehicle movements on the existing parking area.
The warehouse portion of The Soil Factory project:
Interior space is 6,000 sq ft,of which 1500 sq ft is office and bathrooms and the
remaining area is two workshops of approx 3000 and 1500 sq ft respectively.The
building was originally constructed as an S.Discussions with the Town suggested that
an F use is appropriate for the intended research and development use.
A review by Hallam Engineering (attachment)identified minor changes needed to exit
lighting and ventilation.These changes were completed in 2023 and inspected.
Here are the ongoing projects on the grounds of The Soil Factory at 142 Ithaca Beer
Drive…
Marshy Garden:
An experiment on restoring and reintroducing native plant species in otherwise wet,
fallow,and barren rock fill,with minimum ground cover.This experiment is now 3 years
old with over a thousand plants,most grown from scratch from local seed banks.It
serves as both an area resource for learning about native plants,insects,the process of
succession,an inspiration for our visiting artists,as well as a source of food for area
pollinators (moths,butterflies,bees,etc).Some of the plants grown include:Wild
Bergamot,Virginia Wild Rye,Blue Lobelia,Blue Vervain,Elderberry,Common Boneset
and Swamp Milkweed amongst many others.
Miyawaki Test Forest:
An experimental fast growth micro forest,where we are measuring soil health,carbon
sequestration,exploring the value of different sources of nutrients,and growing
conditions,all with local plants.This is a joint project with our partners at Trees Up
Tompkins.Some of the test plants are Red Oak,Red Maple,Black Cherry,Butternut
Hickory,Black Oak,American Hornbeam,and Witch Hazel.
Research Garden:
A project experimenting with creating low cost and safe environments that can be used
to grow food and medicinal plants in a variety of urban and peri-urban environments
featuring compost,biochar,straw bales or similar source materials,all components of a
circular bio-nutrient economy.Outcomes suggest straw bales as a good compostable
base for defining and structuring the garden and storing nutrients.Experiments
continue.
Experimental Nutrient Recovery:
Eco Loo and Fuchs source separating toilets,experiments with designing effective,and
low impact portable potties,where urine can be reclaimed as a source of valuable
nutrients for plants,instead of being flushed into city and town sewers.Our current goal
is to streamline the process of nutrient capture and to create an inexpensive and
reversible ADA compliant porta-potty with water source.Observations to date suggest :
biochar can be used as an absorbent storage base for Nitrogen and Phosphorus
nutrients.
The Field:
Multi-use area for families,community members,scientists,and artists (for picnics,
experimentation,art projects,community gatherings).
In order to allow larger events we are in negotiations to rent parking from our neighbors
for occasional overflow use.
The outdoor platform is used for storage space and accessed from the tarmac.It also
serves as a home for our outdoor cob oven,a thick fire-safe immovable heavy clay oven
built and used for cooking pizza and other foods during occasional outdoor events,used
and accessed only from the tarmac level.
Key for C1 map:see site plan.
1.Marshy Garden is located at Southwest corner approx.60’from west lot line
2.Miyawaki Forest is located at Northwest corner of lot
3.Research Garden is located at Northeast corner of the growing site
Pg. 1
PROPOSED RESOLUTION: Preliminary & Final Site Plan Approval
The Soil Factory – A Project of Weave Community
142 Ithaca Beer Drive
Tax Parcel No.’s 33.-3-2.3 & 33.-3-2.5
Town of Ithaca Planning Board, May 7, 2024
WHEREAS:
1. This action is the consideration of Preliminary and Final Site Plan Approval for the Soil
Factory, a Project of Weave Community, located at 142 Ithaca Beer Drive within the Light
Industrial Zone and Inlet Valley Center Overlay District. The project involves establishing
soil research test gardens on the site, along with multi-disciplinary meeting, workshop, and
event spaces classified as Community Workshop and Place of Assembly uses in the existing
buildings. Site improvements include delineating bicycle, vehicle, pedestrian circulation, and
parking areas. There are no proposed exterior changes to the existing buildings. Greentree
Ithaca, LLC, Owner; Neil Schill, Applicant/Agent,
2. This is a Type II Action, pursuant to 6 NYCRR Section 617.5(c)(2) of the regulations of the
New York State Department of Environmental Conservation promulgated pursuant to the
State Environmental Quality Review Act, as the action constitutes a “replacement,
rehabilitation, or reconstruction of a structure or facility, in kind, on the same site, including
upgrading buildings to meet building or fire codes,” and thus, approval of the site plan is not
subject to review under SEQR,
3. The Planning Board, at a public hearing held on May 7, 2024, has reviewed, and accepted as
adequate an undated narrative, a Basis of Design report prepared by Hallam ICS, dated
08/09/2022 (revised 06/12/2023), site plans titled “The Soil Factory, 142 Ithaca Beer Drive,
Ithaca, NY14850,” including Sheets C1 and C2, prepared by Claudia Brenner, dated 04-02-
2024, and other application materials, and
4. Project plans, and related information, were duly delivered to the Tompkins County Planning
and Sustainability Department per New York State General Municipal Law §§239-l et seq.,
and such Department responded in a April 24, 2024, letter from Katherine Borgella,
Tompkins County Commissioner of Planning, pursuant to §§239-l, -m, and -n of the New
York State General Municipal Law, determining that the proposed action will have no
significant county-wide or inter-community impact;
NOW THEREFORE BE IT RESOLVED THAT:
1. The Planning Board hereby waives certain requirements for Preliminary and Final Site Plan
Approval, as shown on the Preliminary and Final Site Plan Checklists, having determined
from the materials presented that such waiver will result in a significant alteration of neither
the purpose of site plan control nor the policies enunciated or implied by the Town Board,
2. The Planning Board hereby grants Preliminary and Final Site Plan Approval for the proposed
modifications to the Soil Factory, a Project of Weave Community, as described in the items
noted in Whereas # 3 above, [If there are conditions]…subject to the following conditions:
a. [placeholder in case there are conditions…]
Pg. 2
3. Pursuant to Section 270-227 (A) (2) and (3) of the Town Code, the Planning Board hereby
authorizes a 9% reduction in the number of required parking spaces for the project, finding
that the reduction in the required number of parking spaces will not adversely affect traffic
flow on the project site, will leave adequate parking for all of the reasonably anticipated uses
or occupancies in the project, and will not otherwise adversely affect the general welfare of
the community,
4. Pursuant to Section 270-227 (A) (4) of the Town Code, the Planning Board hereby authorizes
a reduction in the standard 180 square foot parking space size, to no less than 162 square
feet, finding that the reduction will not cause any adverse effects on the project, on the
surrounding properties, or on the neighborhood, and
5. Pursuant to Section 270-227.B (2) and (3) of the Town Code, the Planning Board hereby
authorizes the placement of parking in the front yard of the project site, finding that:
a. The particular use, nature, or location of the proposed project or building, requires that
parking be in one of such yards,
b. It is not practicable to limit parking to areas outside the required yard,
c. Parking in such yard does not significantly adversely affect adjacent properties or the
character of the neighborhood, and
d. No such parking will occur in any buffer areas.
COMMISSIONER
Katherine Borgella
DEPUTY COMMISSIONER
M. Megan McDonald
121 E. Court St, Ithaca, N.Y. 14850 | Phone: (607) 274-5560 | tompkinscountyny.gov/planning
Creating and implementing plans that position Tompkins County communities to thrive.
April 24, 2024
Christine Balestra, Senior Planner
Town of Ithaca
215 North Tioga St.
Ithaca, NY 14850
Re: Review Pursuant to §239 -l, -m and -n of New York State General Municipal Law
Proposed Action: Site Plan for the Soil Factory located at 142 Ithaca Beer Drive, Tax
Parcel #33.-3-2.3, John Gaunt, Owner; Neil Schill, Applicant.
Dear Ms. Balestra:
This letter acknowledges your referral of the proposed action identified above for review by the
Tompkins County Department of Planning and Sustainability pursuant to §239 -l, -m and -n of the New
York State General Municipal Law.
We have determined the proposed action will have no significant county-wide or inter-community impact.
We look forward to receiving notification on the final action taken by your municipality within 30 days of
decision, as required by State law.
Sincerely,
Katherine Borgella, AICP
Commissioner of Planning and Sustainability
,.I’.?‘JI
Planning Department site visit – Soil Factory – 4-24-2024
1
View from entrance to property (brick structure is the office building, followed by open canopy loading
dock, and the main Soil Factory warehouse building)
Office building
Planning Department site visit – Soil Factory – 4-24-2024
2
Canopy-Loading dock, one side
Canopy-Loading dock, other side
Planning Department site visit – Soil Factory – 4-24-2024
3
View along warehouse building frontage
View of warehouse, loading dock, and warehouse from adjacent field and hillside (also part of project)
Planning Department site visit – Soil Factory – 4-24-2024
4
Research plots/test fields on adjacent field – facing Elmira Road (both pictures)
GRAVEL ROADASPHALTWAREHOUSEOFFICE BLDG34.60'61.50'25.70'24.70'11.60'LOADING DOCK68° 06' 08"379.77'SW24° 59' 51"229.99'SE68° 06' 22"379.45'NE65° 04' 47"150.72'NE24° 49' 14"229.94'SE24° 55' 00"230.00'NW65° 05' 00"150.00'SWNVACANT LOT2.002 ACRES156111216172060.56'21.50'24.00'19.65'MARSHY GARDENRESEARCH GARDENMIYAWAKI TEST FORESTSIGNAGE: 'ENTER ONE WAY'SIGNAGE: 'EXIT ONLY'OFFICE BUILDING PARKING SPACEHC PARKING SPACE1:20 WITH SIGNAGEINSTALL CHAIN LINK GUARD AT LOADING DOCK SURFACE 42" HIGH W/LOCKABLE GATE. BIKE RACK PARKINGVIF LOCATION3'-0" DEMARCATION ALONG BUILDING FACE FOR PEDESTRIANSDRIVE LANEPROPOSED CLASSIFICATION FPARKING REQUIRED SECTION 270-227• RESEARCH AND DEVELOPMENT6000 SF / 300 SF/PERSON = 20 REQUIREDSPACES PROVIDED - 23•PROVIDED OFFICE BUILDING - USEDWITH RESEARCH FACILITY -600 SF / 300 SF/PERSON = 2 REQUIREDSPACES PROVIDED - 1• UTILIZE/IMPROVE EXISTINGLIGHTING ON WAREHOUSE• PARKING SPACES ARE 9'x18' WITHWHEEL STOPSHC TOILET (SEASONAL) WITH HAND WASHING WILL BE PROVIDED. VIF LOCATION12.00' JM CTBCLAUDIA BRENNERarchitectAPPROVED BYDRAWN BYREVISION DATEREV #DATE421 North Aurora St. #7Ithaca, NY 14850607-275-0715Site PlanC104.02.2024Ithaca, NY 14850The Soil Factory142 Ithaca Beer Drive1.04 1" = 30'-0"1SITE PLAN
JM CTBCLAUDIA BRENNERarchitectAPPROVED BYDRAWN BYREVISION DATEREV #DATE421 North Aurora St. #7Ithaca, NY 14850607-275-0715Site PhotosC204.02.2024Ithaca, NY 14850The Soil Factory142 Ithaca Beer Drive1.04 1/4" = 1'-0"1MARSHY GARDEN - ABOVE 1/4" = 1'-0"2MARSHY GARDEN - FRONT 1/4" = 1'-0"3RESEARCH GARDEN - ABOVE 1/4" = 1'-0"4RESEARCH GARDEN - FRONT 1/4" = 1'-0"5RESEARCH GARDEN - BACK
From:Chris Balestra CBalestra@town.ithaca.ny.us
Subject:RE: 142 Ithaca Beer Drive
Date:September 6, 2023 at 3:33 PM
To :John Gaunt johngaunt84@gmail.com,Marty Moseley MMoseley@town.ithaca.ny.us,Chris Balestra CBalestra@town.ithaca.ny.us
,Mike Smith MSmith@town.ithaca.ny.us
Cc:Neil Schill neil.schill@gmail.com,Abby Homer ahomer@town.ithaca.ny.us,Dana Magnuson DMagnuson@town.ithaca.ny.us,
CJ Randall cjrandall@town.ithaca.ny.us
Hi John and Neil,
We met internally to discuss your project and we compared your proposal to the
Inlet Valley Overlay District regulations and Town Code Section 270-184. We are
confirming that your project requires site plan approval by the Planning Board. It
does not, however, require variances from the Zoning Board.
Please follow the procedures listed below and highlighted on the attached
“Preliminary site plan checklist”. You will only need to submit the materials that are
highlighted in yellow on the attached checklist. Please feel free to call or email me
if you need assistance with the application process.
Here is what you need to submit for a Planning Board appearance: The Planning
Board meets twice per month, on the first and third Tuesday of the month. We
require a “complete” application before scheduling the Planning Board
appearance – the complete application must be in at least 30 days prior to a
scheduled meeting. A complete application includes a digital submission
along with paper copies noted below:
1. Upload submission materials to this link (you’ll complete an online
“Development Review” form and will be able to upload submission materials
as attachments): https://ithacany.viewpointcloud.com/categories/1074/record-
types/6457
2. One digital upload plus one signed paper copy of an Owners Authorization
Form (attached).
3. One digital upload plus 10 paper copies of a narrative that explains the
project. You’ll want to be clear that there are no changes to the property, just
to the use (if that’s what’s happening). Please include information such as:
number of parking spaces that exist, number of people/employees expected
in the building, hours of operation for the uses (you’ll want to further explain
the uses you’ve mentioned to us in our meetings and correspondences), how
the site is utilized, etc.
4. One digital upload of an existing site plan or survey plat prepared by a
licensed surveyor, architect, or engineer, plus 2 printed large size (18 x 24 or
24 x 36) copies and 10 printed copies in 11 x 17 size. Even if you aren’t
proposing any changes at all to the property, the board needs an accurate
plan that shows the building layout, site layout, and parking arrangement on
the property. I’ve attached the site plan that was prepared in 2017 as an
example – the site plan you submit now, though, should show the gardens
and such that are on the site.
5. Payment of review fees: Fees are listed on the town website
here: https://ithacany.viewpointcloud.com/categories/1074/record-types/6457.
We accept cash, checks written out to “Town of Ithaca” and online payments.
Note that the online payments would include a processing fee.
Note that the online payments would include a processing fee.
If you have any further questions about the Inlet Valley Overlay District or the Town
Code, then please call or email Marty Moseley, Director of Code Enforcement, at
(607) 273-1783 or mmoseley@town.ithaca.ny.us.
Cheers,
Chris
Christine Balestra, Planner
Town of Ithaca Planning Department
215 North Tioga Street
Ithaca, NY 14850
(607) 273-1721, ext. 121
cbalestra@town.ithaca.ny.us
From: John Gaunt <johngaunt84@gmail.com>
Sent: Friday, September 1, 2023 9:00 AM
To: Marty Moseley <MMoseley@town.ithaca.ny.us>
Cc: Neil Schill <neil.schill@gmail.com>; Chris Balestra <CBalestra@town.ithaca.ny.us>;
Abby Homer <ahomer@town.ithaca.ny.us>; Dana Magnuson
<DMagnuson@town.ithaca.ny.us>; CJ Randall <cjrandall@town.ithaca.ny.us>
Subject: Re: 142 Ithaca Beer Drive
CJ, Marty, Chris and Dana,
I wanted to thank you for the time you spent with us yesterday.
I appreciate your efforts to implement theTown's vision for economic development in the
Inlet Valley. I believe that the Soil Factory Community Workshop aligns strongly with the
Town's vision and is a great project. As a property owner I support this effort.
I hope our meeting helped you to understand the "Soil Factory". Just to reiterate:
1) The project, a proposed change of occupancy, involves no modifications to the building
or site beyond a change of occupancy from S to F (permit application submitted) to allow
the Soil Factory "Community Workshop" research and development activities.
2) My understanding of the Inlet Valley documentation is that a Community Workshop is
allowable under the base zone and overlay zone and does not require special permit
review.
3) The Office / guest house is not used as a short term rental -and is used in line with
existing zoning documentation..
4) My tenants do not use, or plan to use, the workshop for assembly - defined as
gatherings of more than 50 people.
I trust that with these clarifications we can move forward with the proposed change of
occupancy.
Regards
John
607 882 1698
MEP ENGINEERING
PROCESS CONTROL & PLANT AUTOMATION
COMMISSIONING & VALIDATION
TOXIC GAS MONITORING SYSTEMS
ARC FLASH & ELECTRICAL SAFETY
38 Eastwood Dr., Suite 200, So.Burlington, VT05403 | TEL 802.658.4891 | FAX 802.658.1457 | www.Hallam-ICS.com38 Eastwood Dr., Suite 200, So.Burlington, VT05403 | TEL 802.658.4891 | FAX 802.658.1457 | www.Hallam-ICS.com38 Eastwood Dr., Suite 200, So.Burlington, VT05403 | TEL 802.658.4891 | FAX 802.658.1457 | www.Hallam-ICS.com
38 Eastwood Drive, Suite 200, South Burlington, VT 05403 | TEL 802.658.4891 | FAX 802.658.1457 | www.Hallam-ICS.com
Green Tree
142 Brewery Lane, Ithaca, NY
Basis Of Design
Project Number: 22689.000
Revision History
Revision Date Description of Change
0 08/29/2022 Initial release
1 09/02/2022 Clarifications after 9/2/2022 meeting.
2 06/12/2023 Clarifications about desired occupancy change.
Contents
1 Introduction.......................................................................................................................................................2
1.1 Key Findings.................................................................................................................................................2
2 Relevant Codes.................................................................................................................................................3
2.1 2020 Existing Building Code of New York State...........................................................................................3
2.2 2020 Building Code of New York State ......................................................................................................11
2.3 2020 Fire Code of New York State.............................................................................................................16
2.4 2020 Plumbing Code of New York State....................................................................................................18
2.5 NFPA 10, 2018...........................................................................................................................................19
3 Online Code Resources.................................................................................................................................19
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 2 of 19
1 Introduction
GreenTree owns a facility in Ithaca, NY. The tenants of this space are engaged in a “science means art”
project. The space is currently permitted for storage. The town of Ithaca has stated is not being used
consistently with the current S occupancy. The town stated that the existing use is similar to a research
and development usage. GreenTree has agreed to a path forward with the town to change the use from S
occupancy to F occupancy. GreenTree intends to change the entire building to an F-2 occupancy.
Hallam-ICS prepared this Basis Of Design document for GreenTree to detail the statutory requirement of
changing to an F-2 occupancy.
1.1 Key Findings
1. Fire extinguishers are required in the new occupancy. Hallam-ICS recommends considering the
space an “Ordinary Hazard Occupancy.” Hallam-ICS recommends 2A:10B:C or 2A:20B:C fire
extinguishers. Location requirements:
a. Maximum floor area per extinguisher: 1,500 sq. ft.
b. Maximum distance of travel to extinguishers:
i. For 2A:10B:C extinguishers: 30 ft
ii. For 2A:20B:C extinguishers: 50 ft
2. Carbon monoxide detectors are required.
a. Carbon monoxide detectors need to be listed labeled as complying with UL2034 or CAN/CSA
6.19.
b. Carbon monoxide detectors are required to be located in all rooms and occupiable spaces.
3. Egress modification is not required.
4. Electrical modifications are not required.
5. Means-of-egress lighting in accordance with the building code is required if not already present.
6. Exit signs in accordance with the building code are required if not already present.
7. Mechanical ventilation is required at 0.085 CFM/sq.ft.. The total required flow for the building is 476
CFM This needs to be divided between the building spaces based on floor area.
8. Bathroom exhaust is required at either 25 CFM continuous or 50 CFM intermittent.
9. The required plumbing facilities are provided below. If these do not already exist, they need to be
installed.
a. 1 water closets per 100 occupants
b. 1 lavatory per 100 occupants
c. 1 drinking fountain per 100 occupants
i. If the building owner can confirm that the occupancy load is 15 or fewer, a drinking
fountain is not required.
ii. Where drinking fountains are required, two water fountains are required, or a single
fountain with two separate spouts. One is required for people who use a wheelchair, one
is for people who are standing.
d. 1 service sink
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 3 of 19
2 Relevant Codes
New York State’s 2020 codes adopt the 2018 International Code Council codes with amendments.
2.1 2020 Existing Building Code of New York State
Existing Building Code Text Commentary
SECTION 202 GENERAL DEFINITIONS
CHANGE OF OCCUPANCY. A change in the use
of a building or a portion of a building that results
in any of the following:
1. A change of occupancy classification.
2. A change from one group to another group
within an occupancy classification.
3 Any change in use within a group for which
there is a change in application of the
requirements of this code.
The existing building is S-1, S-2 or U (storage or
utility). The future occupancy will be F-2. See
review of the 2020 Building Code, section 306.
This is a Change of Occupancy.
SECTION 602 ALTERATION-LEVEL 1
602.1 scope.
Level 1 alterations include the removal and
replacement or the covering of existing materials,
elements, equipment, or fixtures using new
materials, elements, equipment, or fixtures that
serve the same purpose.
602.2 Application.
Level 1 alterations shall comply with the
provisions of Chapter 7.
There are no planned alterations. This does not
meet the definition of a level 1 alteration.
SECTION 603 ALTERATION-LEVEL 2
603.1 scope.
Level 2 alterations include the reconfiguration of
space, the addition or elimination of any door or
window, the reconfiguration or extension of any
system, or the installation of any additional
equipment.
603.2 Application.
Level 2 alterations shall comply with the
provisions of Chapter 7 for Level 1 alterations as
well as the provisions of Chapter 8.
There are no planned alterations. This does not
meet the definition of a level 2 alteration.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 4 of 19
Existing Building Code Text Commentary
SECTION 604 ALTERATION—LEVEL 3
604.1 scope.
Level 3 alterations apply where the work area
exceeds 50 percent of the building area.
604.2 Application.
Level 3 alterations shall comply with the
provisions of Chapters 7 and 8 for Level 1 and 2
alterations, respectively, as well as the provisions
of Chapter 9.
There are no planned alterations. This does not
meet the definition of a level 3 alteration.
SECTION 605 CHANGE OF OCCUPANCY
605.1 scope.
Change of occupancy provisions apply where the
activity is classified as a change of occupancy as
defined in Chapter 2.
605.2 Application.
Changes of occupancy shall comply with the
provisions of Chapter 10.
The building is undergoing a change of
occupancy.
The change of occupancy requires following
Chapter 10
SECTION 805
MEANS OF EGRESS
805.1 scope.
The requirements of this section shall be limited to
work areas that include exits or corridors shared
by more than one tenant within the work area in
which Level 2 alterations are being performed,
and where specified they shall apply throughout
the floor on which the work areas are located or
otherwise beyond the work area.
This section is referenced by section 905.1, which
is referenced by section 1011.4.2, so it is
required.
This section only applies to “work areas that
include exits and corridors shared by more than
one tenant.” There is only one tenant in this work
area. Means of egress modifications are not
required.
[NY] 805.3.1.1 Single-exit buildings.
Only one exit is required from buildings and
stories of the following occupancies:
1. In Group A, E, F and U occupancies located on
the level of exit discharge, in buildings not more
than five stories, when the occupant load of the
story is not greater than 50 and the exit access
travel distance is not greater than 75 feet (22.86
m).
Note that this section is not required based on
805.1.
If this section applied, the travel distance would
be required to be 75 feet or less. Hallam-ICS
estimates that the straight line distance from the
egress door to the furthest interior portion of the
building is 64 feet. Depending on the equipment
layout of the space, the egress distance may be
over 75 ft. While not required, Hallam-ICS
recommends organizing any equipment to keep a
75 ft egress path.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 5 of 19
Existing Building Code Text Commentary
SECTION 905
MEANS OF EGRESS
905.1 General.
The means of egress shall comply with the
requirements of Section 805 except as specifically
required in Sections 905.2 and 905.3.
This section is required by 1011.4.2. It references
section 805 which has further means of egress
requirements.
905.2 Means-of-egress lighting.
Means of egress from the highest work area floor
to the floor of exit discharge shall be provided with
artificial lighting within the exit enclosure in
accordance with the requirements of the Building
Code of New York State.
Means-of-egress lighting is required.
905.3 Exit signs.
Means of egress from the highest work area floor
to the floor of exit discharge shall be provided with
exit signs in accordance with the requirements of
the Building Code of New York State.
Exit signs are required.
CHAPTER 10 CHANGE OF OCCUPANCY
SECTION 1001 GENERAL
1001.1 Scope.
The provisions of this chapter shall apply where a
change of occupancy occurs, as defined in
Section 202.
1001.2 Certificate of occupancy.
A change of occupancy or a change of occupancy
within a space where there is a different fire
protection system threshold requirement in
Chapter 9 of the International Building Code shall
not be made to any structure without the approval
of the code official. A certificate of occupancy shall
be issued where it has been determined that the
requirements for the change of occupancy have
been met.
The owner will require a new certificate of
occupancy from the Town of Ithaca.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 6 of 19
Existing Building Code Text Commentary
1001.2.2 Change of occupancy classification or
group.
Where the occupancy classification of a building
changes, the provisions of Sections 1002 through
1011 shall apply. This includes a change of
occupancy classification and a change to another
group within an occupancy classification.
1001.2.2.1 Partial change of occupancy.
Where the occupancy classification or group of a
portion of an existing building is changed, Section
1011 shall apply.
All of chapter 10 applies to this project.
SECTION 1002
SPECIAL USE AND OCCUPANCY
1002.1 Compliance with the building code.
Where the character or use of an existing building
or part of an existing building is changed to one of
the following special use or occupancy categories
as defined in the Building Code of New York
State, the building shall comply with all of the
applicable requirements of the Building Code of
New York State:
1. Covered and open mall buildings.
2. Atriums.
3. Motor vehicle-related occupancies.
4. Aircraft-related occupancies.
5. Motion picture projection rooms.
6. Stages and platforms.
7. Special amusement buildings.
8. Incidental use areas.
9. Hazardous materials.
10. Ambulatory care facilities.
11. Group 1-2 occupancies.
Most of these items clearly do not apply.
Motor vehicle-related occupancy applies if the
owner will use a portion of the building to perform
work on motor vehicles. See review of section
building code 406.
Hazardous materials does not apply. The building
code defines this as “buildings and structures
occupied for the manufacturing, processing,
dispensing, use or storage of hazardous
materials.” That definition does not apply to this
usage.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 7 of 19
Existing Building Code Text Commentary
SECTION 1004
FIRE PROTECTION
1004.1 General.
Fire protection requirements of Section 1011 shall
apply where a building or portions thereof undergo
a change of occupancy classification or where
there is a change of occupancy within a space
where there is a different fire protection system
threshold requirement in Chapter 9 of the Building
Code of New York State.
Section 1011 indicates fire protection is required
where Chapter 9 in the building code requires fire
protection. See review of building code, chapter 9.
SECTION 1005
MEANS OF EGRESS
Means of egress in portions of building
undergoing a change of occupancy classification
shall comply with Section 1011.
Section 1005 references section 1011.4 Refer to
section 1011.4 code and commentary.
SECTION 1006
STRUCTURAL
No commentary
[BS] 1006.1 Live loads.
Structural elements carrying tributary live loads
from an area with a change of occupancy shall
satisfy the requirements of Section 1607 of the
Building Code of New York State. Design live
loads for areas of new
occupancy shall be based on Section 1607 of the
Building Code of New York State. Design live
loads for other areas shall be permitted to use
previously approved design live loads.
There are no live load structural elements as this
is a single story building.
[BS] 1006.2 Snow and wind loads.
Where a change of occupancy results in a
structure being assigned to a higher risk category,
the structure shall satisfy the requirements of
Sections 1608 and 1609 of the Building Code of
New York State for the new risk category.
The risk category of the existing and new
occupancy class is II, so no change is required.
[BS] 1006.3 seismic loads.
Where a change of occupancy results in a building
being assigned to a higher risk category, the
building shall satisfy the requirements of Section
1613 of the Building Code of New York State for
the new risk category using full seismic forces.
The risk category of the existing and new
occupancy class is II so no change is required.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 8 of 19
Existing Building Code Text Commentary
SECTION 1007
ELECTRICAL
No commentary
1007.1 Special occupancies.
Where the occupancy of an existing building or
part of an existing building is changed to one of
the following special occupancies as described in
NFPA 70, the electrical wiring and equipment of
the building or portion thereof that contains the
proposed occupancy shall comply with the
applicable requirements of NFPA 70 whether or
not a change of occupancy group is involved:
1. Hazardous locations.
2. Commercial garages, repair and storage.
3. Aircraft hangars.
4. Gasoline dispensing and service stations.
5. Bulk storage plants.
6. Spray application, dipping and coating
processes.
7. Health care facilities.
8. Places of assembly.
9. Theaters, audience areas of motion
picture and television studios, and similar
locations.
10. Motion picture and television studios and
similar locations.
11. Motion picture projectors.
12. Agricultural buildings.
None of these special occupancies applies.
1007.2 Unsafe conditions.
Where the occupancy of an existing building or
part of an existing building is changed, all unsafe
conditions shall be corrected without requiring that
all parts of the electrical system comply with
NFPA 70.
There are no unsafe electrical conditions.
1007.4 no additional outlets required
1007.3 Service upgrade.
Where the occupancy of an existing building or
part of an existing building is changed, electrical
service shall be upgraded to meet the
requirements of NFPA 70 for the new occupancy.
We understand this to require any new electrical
work to comply with NFPA 70. There are no new
electrical loads or requirements with the change
of occupancy.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 9 of 19
Existing Building Code Text Commentary
1007.4 Number of electrical outlets.
Where the occupancy of an existing building or
part of an existing building is changed, the number
of electrical outlets shall comply with NFPA 70 for
the new occupancy.
No additional outlets are required for an F-2
occupancy.
SECTION 1008
MECHANICAL
1008.1 Mechanical requirements.
Where the occupancy of an existing building or
part of an existing building is changed such that
the new occupancy is subject to different kitchen
exhaust requirements or to increased mechanical
ventilation requirements in accordance with the
Mechanical Code of New York State, the new
occupancy shall comply with the respective
Mechanical Code of New York State provisions.
Table 403.1.1 of the mechanical code defines
ventilation rates. The previous occupancy
classification was “warehouse,” the new
occupancy will be “work room.” The new
occupancy has airflow requirements greater than
the previous occupancy, modifications to the
airflow are required.
The closest occupancy classification are items
considered workrooms. We consider this closest
to “Bank vaults/safedeposit” or “Computer
(without printing)”. The requirements for these
areas are:
4-5 people/1000 sq.ft. We will assume 5
people/1000 sq.ft.
5 CFM/person
0.06 CFM/sq.ft.
The requirements above add up to 0.085
CFM/sq.ft. For this building of approximately
5,600 sq.ft. the required airflow is 476 CFM. This
flow needs to be divided between the building
spaces based on the floor area. Hallam-ICS
expects that energy recovery units (ERUs) will be
the most economical option for this. The solution
may consist of a single ERU with ducted supply
and return to each building area, or several
ERUs.
Table 403.1.1 requires exhaust air for bathrooms.
This can be either 25 CFM continuous or 50 CFM
intermittent.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 10 of 19
Existing Building Code Text Commentary
SECTION 1009
PLUMBING
1009.1 Increased demand.
Where the occupancy of an existing building or
part of an existing building is changed such that
the new occupancy is subject to increased or
different plumbing fixture requirements or to
increased water supply requirements in
accordance with the Plumbing Code of New York
State, the new occupancy shall comply with the
intent of the respective Plumbing Code of New
York State provisions.
This section requires new plumbing demands
comply with the building code.
Refer to the plumbing code review.
SECTION 1010
OTHER REQUIREMENTS
1010.1 Light and ventilation.
Light and ventilation shall comply with the
requirements of the Building Code of New York
State for the new occupancy.
This section requires the new work to comply with
the building code light and ventilation.
The building code references the mechanical
code for ventilation. Refer to section 1008
commentary.
10 footcandels requires. We assume this is the
case.
SECTION 1011
CHANGE OF OCCUPANCY CLASSIFICATION
This section provides requirements that largely
match requirements in other sections.
1011.4 Means of egress, general.
Hazard categories in regard to life safety and
means of egress shall be in accordance with
Table 1011.4
TABLE 1011.4 MEANS OF EGRESS HAZARD
CATEGORIES
This table provides hazard classifications.
1011.4.1 Means of egress for change to a higher-
hazard category.
Where a change of occupancy classification is
made to a higher-hazard category (lower number)
as shown in Table 1011.4, the means of egress
shall comply with the requirements of Chapter 10
of the Building Code of New York State.
F-2 is the lowest classification hazard. The
requirements of this section do not apply.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 11 of 19
Existing Building Code Text Commentary
1011.4.2 Means of egress for change of use to an
equal or lower-hazard category.
Where a change of occupancy classification is
made to an equal or lesser-hazard category
(higher number) as shown in Table 1011.4,
existing elements of the means of egress shall
comply with the requirements of Section 905 for
the new occupancy classification. Newly
constructed or configured means of egress shall
comply with the requirements of Chapter 10 of the
Building Code of New York State.
F-2 is the lowest classification hazard. The
requirements of this section apply.
This section references section 905, which then
references section 805.
2.2 2020 Building Code of New York State
Building Code Text Commentary
SECTION 202
DEFINITIONS
This section provides definitions for words and
terms in this code.
306.2 Moderate-hazard factory industrial, Group
F-1
Factory industrial uses that are not classified as
Factory Industrial F-2 Low Hazard shall be
classified as F-1 Moderate Hazard and shall
include, but not be limited to, the following:
Aircraft (manufacturing, not to include repair)
Appliances
Athletic equipment
Automobiles and other motor vehicles
Bakeries
Beverages: over 16-percent alcohol content
Bicycles
Boats
Brooms or brushes
REMAINDER OF EXAMPLES NOT LISTED
HERE.
Group F-1 does not apply to the use of this space.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 12 of 19
Building Code Text Commentary
306.3 Low-hazard factory industrial, Group F-2.
Factory industrial uses that involve the fabrication
or manufacturing of noncombustible materials that
during finishing, packing or processing do not
involve a significant fire hazard shall be classified
as F-2 occupancies and shall include, but not be
limited to, the following:
Beverages: up to and including 16-percent alcohol
content
Brick and masonry
Ceramic products
Foundries
Glass products
Gypsum
Ice
Metal products (fabrication and assembly)
The client’s usage is similar to that of a research
and development facility. The description for an F-
2 space most closely matches the tenant’s use of
the space. The new occupancy will be F-2.
[F] 903.2 Where required.
Approved automatic sprinkler systems in new
buildings and structures shall be provided in the
locations described in Sections 903.2.1 through
903.2.12.
This section defines where an automatic sprinkler
system is required. It does not have any
requirements listed for Group F-2. An automatic
sprinkler system is not required.
[F] 905.3 Required installations.
Standpipe systems shall be installed where
required by Sections 905.3.1 through 905.3.8.
Standpipe systems are allowed to be combined
with automatic sprinkler systems.
Exception: Standpipe systems are not required in
Group R-3 occupancies.
[F] 905.3.1 Height.
Class Ill standpipe systems shall be installed
throughout buildings where any of the following
conditions exist:
1. Four or more stories are above or below grade
plane.
2. The floor level of the highest story is located
more than 30 feet (9144 mm) above the lowest
level of fire department vehicle access.
3 The floor level of the lowest story is located
more than 30 feet (9144 mm) below the highest
level of fire department vehicle access.
Exceptions not shown here.
Section 905.3 lists where standpipes are required.
Standpipes are not required based on the
building’s height. Sections 905.3.2-905.3.8 are
specific conditions that do not apply to this
building. Stand pipes are not required.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 13 of 19
Building Code Text Commentary
[F] 906.1 Where required.
Portable fire extinguishers shall be installed in all
of the following locations:
1. In Group A, B, E, F, H, 1, M, R-1, R-4 and S
occupancies.
Exceptions not shown here.
2. In areas where flammable or combustible
liquids are stored, used or dispensed.
3. On each floor of structures under construction,
except Group R-3 occupancies, in accordance
with Section 3315.1 of the Fire Code of New York
State.
4. Where required by the Fire Code of New York
State sections indicated in Table 906.1.
5. Special-hazard areas, including but not limited
to laboratories, computer rooms and generator
rooms, where required by the fire code official.
6. Special-hazard areas, including but not limited
to laboratories computer rooms and generator
rooms, where required by the fire code official.
Fire extinguishers are required.
[F] 906.3 Size and distribution.
The size and distribution of portable fire
extinguishers shall be in accordance with Sections
906.3.1 through 906.3.4.
No commentary.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 14 of 19
Building Code Text Commentary
[F] 906.3.1 Class A fire hazards.
The minimum sizes and distribution of portable fire
extinguishers for occupancies that involve
primarily Class A fire hazards shall comply with
Table 906.3(1).
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR
CLASS A FIRE HAZARDS
This table applies to class A fire extinguishers.
Hallam-ICS recommends considering the space
an ordinary hazard occupancy.
Minimum requirements for an ordinary hazard
occupancy:
2-A rated extinguisher
Maximum floor area per extinguisher:
1,500 sq. ft.
Maximum distance of travel to
extinguisher: 75 ft.
[F] 906.3.2 Class B fire hazards.
Portable fire extinguishers for occupancies
involving flammable or combustible liquids with
depths less than or equal to 0.25-inch (6.4 mm)
shall be selected and placed in accordance with
Table 906.3(2).
Portable fire extinguishers for occupancies
involving flammable or combustible liquids with a
depth of greater than 0.25-inch (6.4 mm) shall be
selected and placed in accordance with NFPA 10.
[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR
FLAMMABLE OR COMBUSTIBLE LIQUIDS
WITH DEPTHS LESS THAN OR EQUAL TO 0.25
This table applies to class B fire extinguishers.
Hallam-ICS recommends considering the space
an ordinary hazard occupancy.
Maximum distance of travel to extinguishers for
an ordinary hazard occupancy:
For 10-B rated extinguisher, 30 ft
For 20-B rated extinguisher, 50 ft
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 15 of 19
Building Code Text Commentary
[F] 906.3.3 Class C fire hazards.
Portable fire extinguishers for Class C fire hazards
shall be selected and placed on the basis of the
anticipated Class A or B hazard.
Hallam-ICS recommends that the owner purchase
ABC rated fire extinguishers.
[F] 906.3.4 Class D fire hazards.
Portable fire extinguishers for occupancies
involving combustible metals shall be selected
and placed in accordance with NFPA 10.
Combustible metal fires do not apply to this
building use.
[F] 907.2.4 Group F.
A manual fire alarm system that activates the
occupant notification system in accordance with
Section 907.5 shall be installed in Group F
occupancies where both of the following
conditions exist:
1. The Group F occupancy is two or more stories
in height.
2. The Group F occupancy has a combined
occupant load of 500 or more above or below the
lowest level of exit discharge.
Exception: Manual fire alarm boxes are not
required where the building is equipped
throughout with an automatic sprinkler system
installed in accordance with Section 903.3.1.1 and
the occupant notification appliances will activate
throughout the notification zones upon sprinkler
water flow.
Neither of the conditions listed apply. A manual
fire alarm system is not required.
SECTION 915
CARBON MONOXIDE DETECTION
[NY] 915.1 General.
Carbon monoxide alarms and carbon monoxide
detection shall be installed in new and existing
buildings in accordance with Section 915 of the
Fire Code of New York State.
Section 915 requires following the fire code.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 16 of 19
Building Code Text Commentary
SECTION 1204
LIGHTING
1204.1 General.
Every space intended for human occupancy shall
be provided with natural light by means of exterior
glazed openings in accordance with Section
1204.2 or shall be provided with artificial light in
accordance with Section 1204.3. Exterior glazed
openings shall open directly onto a public way or
onto a yard or court in accordance with Section
1205.
Lighting is required.
1204.3 Artificial light.
Artificial light shall be provided that is adequate to
provide an average illumination of 10 footcandles
(107 lux) over the area of the room at a height of
30 inches (762 mm) above the floor level.
The lighting in the building meets the 10
footcandle requirement in this section.
2.3 2020 Fire Code of New York State
Fire Code Text Commentary
[NY] 915.1 General.
New and existing residential buildings and
commercial buildings shall be provided with
carbon monoxide detection and notification in
accordance with this Section 915.
Carbon monoxide detection is required.
[NY] 915.3.1 Residential buildings and commercial
buildings that contain a fuel-buming appliance.
Carbon monoxide detection shall be installed in
residential buildings and commercial buildings in
all rooms, occupiable space, dwelling units,
sleeping areas, and sleeping units that contain a
fuel-burning appliance.
The owner’s unit heaters burn fuel. This section
applies.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 17 of 19
Fire Code Text Commentary
[NY] 915.3.2 Commercial buildings served by a
fuelburning forced-air furnace.
Carbon monoxide detection shall be installed in a
central or otherwise approved location in
commercial buildings in the following locations
when such location is served by a fuel-burning
forced-air furnace:
1. In each HVAC zone on every floor level that is
served by a fuel-burning forced air furnace.
2. In sleeping units, sleeping areas in day care
facilities, and in every classroom in a Group E
occupancy that is served by a fuel-burning forced-
air furnace.
3. Outside of sleeping areas and within 10 feet
(3048 mm) of the entrance to the sleeping areas
in dwelling units.
This section states where carbon monoxide
detection is required.
Carbon monoxide detectors are located in each
HVAC zone. Section 915.3.2 already requires
carbon monoxide detection in every room.
[NY] 915.3.3 Residential buildings and commercial
buildings with an attached motor vehicle related
occupancy.
Carbon monoxide detection shall be installed in a
central or otherwise approved location in each
occupiable space in a commercial building and
within 10 feet (3048 mm) of the entrance to
sleeping areas and sleeping units in residential
buildings and commercial buildings that:
1. Have a communicating opening with an
attached motor vehicle related occupancy,
2. Share one or more common walls with an
attached motor vehicle related occupancy, or
3. Are located one story above or below a motor
vehicle related occupancy.
This section states where carbon monoxide
detection is required. It does not provide any
requirements above the requirements in 915.3.1
for this building.
[NY] 915.4.1.2 Carbon monoxide alarm listing.
Carbon monoxide alarms shall be listed and
labeled as complying with UL 2034 or CAN/CSA
6.19.
Carbon monoxide detectors need to be listed
labeled as complying with UL2034 or CAN/CSA
6.19.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 18 of 19
2.4 2020 Plumbing Code of New York State
Plumbing Code Text Commentary
SECTION 403
MINIMUM PLUMBING FACILITIES
Table not shown here.
Factory and industrial occupancies require:
1 per 100 water closets
1 per 100 lavatories
1 per 100 drinking fountains
1 service sink
The building has a water closet and lavatory. If
the building does not have a service sink and
drinking fountain, these must be installed.
410.2 Small occupancies.
Drinking fountains shall not be required for an
occupant load of 15 or fewer.
If the owner can confirm that the occupancy load
of the building is 15 or fewer people, a drinking
fountain is not required.
[BE] 410.3 High and low drinking fountains.
Where drinking fountains are required, not fewer
than two drinking fountains shall be provided. One
drinking fountain shall comply with the
requirements for people who use a wheelchair
and one drinking fountain shall comply with the
requirements for standing persons.
Exceptions:
1. A single drinking fountain with two separate
spouts that complies with the requirements for
people who use a wheelchair and standing
persons shall be permitted to be substituted for
two separate drinking fountains.
2. Where drinking fountains are primarily for
children's use, the drinking fountains for people
using wheelchairs shall be permitted to comply
with the children's provisions in ICC A 117.1 and
drinking fountains for standing children shall be
permitted to provide the spout at 30 inches (762
mm) minimum above the floor.
Two water fountains are required, or a single
fountain with two separate spouts. One is
required for people who use a wheelchair, one is
for people who are standing.
GREEN TREE
142 BREWERY LANE, ITHACA, NY
BASIS OF DESIGN
Green Tree 142 Brewery Lane Basis Of Design.docx 19 of 19
2.5 NFPA 10, 2018
NFPA 10 Text Commentary
5.4.1.1 * Light Hazard. Light hazard occupancies
shall be classified as locations where the quantity
and combustibility of Class A combustibles and
Class B flammables are low and fires with
relatively low rates of heat release are expected.
These occupancies consist of fire hazards having
normally expected quantities of Class A
combustible furnishings, and/or the total quantity of
Class B flammables typically expected to be
present is less than 1 gal (3.8 L) in any room or
area.
This is the definition of “Light Hazard”. Depending
on the activities of the tenants activities this may
apply. We recommend conservatively placing fire
extinguishers base on “Ordinary Hazard”
5.4.1.2* Ordinary Hazard. Ordinary hazard
occupancies shall be classified as locations where
the quantity and combustibility of Class A
combustible materials and Class B flammables are
moderate and fires with moderate rates of heat
release are expected. These occupancies consist
of fire hazards that only occasionally contain Class
A combustible materials beyond normal
anticipated furnishings, and/or the total quantity of
Class B flammables typically expected to be
present is from 1 gal to 5 gal (3.8 L to 18.9 L) in
any room or area.
This is the definition of “Ordinary Hazard”.
Depending on the activities of the tenant activities
this may apply. We recommend conservatively
placing fire extinguishers base on “Ordinary
Hazard”
5.4.1.3* Extra Hazard. Extra hazard occupancies
shall be classified as locations where the quantity
and combustibility of Class A combustible material
are high or where high amounts of Class B
flammables are present and rapidly developing
fires with high rates of heat release are expected.
These occupancies consist of fire hazards involved
with the storage, packaging, handling, or
manufacture of Class A combustibles, and/or the
total quantity of Class B flammables expected to
be present is more than 5 gal (18.9 L) in any room
or area.
This definition does not apply to the tenant’s use.
3 Online Code Resources
Access to New York State ICC codes is available for free at: https://codes.iccsafe.org/codes/new-york
Access to the National Fire Protection Association (NFPA) standards is available for free at:
https://www.nfpa.org/
End
Pg. 1
PROPOSED RESOLUTION: Preliminary & Final Site Plan Approval
The Soil Factory – A Project of Weave Community
142 Ithaca Beer Drive
Tax Parcel No.’s 33.-3-2.3 & 33.-3-2.5
Town of Ithaca Planning Board, May 7, 2024
WHEREAS:
1. This action is the consideration of Preliminary and Final Site Plan Approval for the Soil
Factory, a Project of Weave Community, located at 142 Ithaca Beer Drive within the Light
Industrial Zone and Inlet Valley Center Overlay District. The project involves establishing
soil research test gardens on the site, along with multi-disciplinary meeting, workshop, and
event spaces classified as Community Workshop and Place of Assembly uses in the existing
buildings. Site improvements include delineating bicycle, vehicle, pedestrian circulation, and
parking areas. There are no proposed exterior changes to the existing buildings. Greentree
Ithaca, LLC, Owner; Neil Schill, Applicant/Agent,
2. This is a Type II Action, pursuant to 6 NYCRR Section 617.5(c)(182) of the regulations of
the New York State Department of Environmental Conservation promulgated pursuant to the
State Environmental Quality Review Act, as the action constitutes a “reuse of a residential or
commercial structure, or of a structure containing mixed residential and commercial uses,
where the residential or commercial use is a permitted use under the applicable zoning law or
ordinance, including permitted by special use permit, and the action does not meet or exceeds
any of the thresholds in section 617.4 of this Part;”replacement, rehabilitation, or
reconstruction of a structure or facility, in kind, on the same site, including upgrading
buildings to meet building or fire codes,” and thus, approval of the site plan is not subject to
review under SEQR,
3. The Planning Board, at a public hearing held on May 7, 2024, has reviewed, and accepted as
adequate an undated narrative, a Basis of Design report prepared by Hallam ICS, dated
08/09/2022 (revised 06/12/2023), site plans titled “The Soil Factory, 142 Ithaca Beer Drive,
Ithaca, NY14850,” including Sheets C1 and C2, prepared by Claudia Brenner, dated 04-02-
2024, and other application materials, and
4. Project plans, and related information, were duly delivered to the Tompkins County Planning
and Sustainability Department per New York State General Municipal Law §§239-l et seq.,
and such Department responded in a April 24, 2024, letter from Katherine Borgella,
Tompkins County Commissioner of Planning, pursuant to §§239-l, -m, and -n of the New
York State General Municipal Law, determining that the proposed action will have no
significant county-wide or inter-community impact;
NOW THEREFORE BE IT RESOLVED THAT:
1. The Planning Board hereby waives certain requirements for Preliminary and Final Site Plan
Approval, as shown on the Preliminary and Final Site Plan Checklists, having determined
from the materials presented that such waiver will result in a significant alteration of neither
the purpose of site plan control nor the policies enunciated or implied by the Town Board,
Pg. 2
2. The Planning Board hereby grants Preliminary and Final Site Plan Approval for the proposed
modifications to the Soil Factory, a Project of Weave Community, as described in the items
noted in Whereas # 3 above, [If there are conditions]…subject to the following conditions:
a. [placeholder in case there are conditions…]
3. Pursuant to Section 270-227 (A) (2) and (3) of the Town Code, the Planning Board hereby
authorizes a 9% reduction in the number of required parking spaces for the project, finding
that the reduction in the required number of parking spaces will not adversely affect traffic
flow on the project site, will leave adequate parking for all of the reasonably anticipated uses
or occupancies in the project, and will not otherwise adversely affect the general welfare of
the community,
4. Pursuant to Section 270-227 (A) (4) of the Town Code, the Planning Board hereby authorizes
a reduction in the standard 180 square foot parking space size, to no less than 162 square
feet, finding that the reduction will not cause any adverse effects on the project, on the
surrounding properties, or on the neighborhood, and
5. Pursuant to Section 270-227.B (2) and (3) of the Town Code, the Planning Board hereby
authorizes the placement of parking in the required front yard of the project site, finding that:
a. The particular use, nature, or location of the proposed project or building, requires that
parking be in one of such yards,
b. It is not practicable to limit parking to areas outside the required yard,
c. Parking in such yard does not significantly adversely affect adjacent properties or the
character of the neighborhood, and
d. No such parking will occur in any buffer areas.