Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPC Packet 2023-08-17 4 TOWN OF ITHACA
„ Y, NEW YORK
PLANNING DEPARTMENT
215 N.Tioga St 14850
607.273.1747
www.townJthaca.nV.us
TOWN OF ITHACA PLANNING COMMITTEE
THURSDAY,AUGUST 17, 2023 at 3:00 P.M.
Meeting Location: Ithaca Town Hall, 215 N. Tioga Street, Aurora Conference Room
(Enter from the rear entrance of Town Hall, adjacent employee parking lot.)
Members of the public may also join the meeting virtually via Zoom at
https://us06web.zoom.us/j/6750593272.
AGENDA
1. Persons to be heard.
2. Committee announcements and concerns.
3. Consider approval of July meeting minutes.
4. Continue consideration of request for a Limited Historic Commercial Overlay District for
1296-1298 Trumansburg Rd.
5. Staff updates and reports.
6. Discuss next meeting date and upcoming agenda items.
A quorum of the Ithaca Town Board may be present, however,
no official Board business will be conducted.
Town of Ithaca Planning Committee
Thursday,July 20, 2023
(3:00 PM Aurora Conference Room and on Zoom)
Draft Minutes
Committee members: Rich DePaolo, Chair; Rod Howe; Margaret Johnson.
Board/Staff members: Director of Planning C.J. Randall; Town Civil Engineer Sam Jilson; Director of
Codes Marty Moseley(3:15).
Guests: Sandra Schmitz via Zoom.
1. Persons to be heard: None
2. Committee announcements and concerns: Rod asked to add proposed RaNic Planned Development
Zone to the end of the meeting for an update.
3.Approval of May meeting minutes: Rod moved; Margaret seconded. The May 18, 2023, minutes
were approved with two minor changes.
4. Consider request for a Limited Historic Commercial Overlay District for Hayt's Chapel and
Schoolhouse 1296-1298 Trumansburg Road. Property owner Alexa Schmitz submitted a Narrative
Description and Justification for the request along with a proposed Preservation Plan and Inspection
Report with photos.Alexa and her husband were unable to attend the meeting; Sandra Schmitz joined
via Zoom videoconference on the applicant's behalf. It was noted that this historic property has been
used as a long-term and short-term rental property without permit or restrictions.Applying for
enactment of Limited Historic Commercial Overlay District would permit and formalize milestones and
deliverables to preserve the historic nature of the property.
Upon review of the documents provided, the committee asked for a revised draft Narrative and
Preservation plan with the addition or clarification of the following:
Add the text"number of days" after"unlimited" on page 1. Proposed Use.
Under Feasibility, the committee wanted clarity on the number of sleeping units and
total proposed occupancy (set up for 2 adults, 2 children currently per Sandra).Note
was made that this will be determined ultimately by the Codes department.
Page 2, the statement that"It will also permit more members of the public each year to
appreciate the historic structures"was asked to be clarified as the use of the buildings is
not proposed to be changed from its previous use, possibly this means compared to the
base zoning restrictions.
There should be consistency between the items noted for immediate correction and the
Preservation Plan (some are under the within 2-year timeline but noted elsewhere in the
inspection report as immediate) as well as the specific materials proposed to be used in
the repairs.
Clarify timeline under 121 Long Term property maintenance "regular inspection and
maintenance". Who classifies the "professional"to inspect the exterior every 5 years.
Next steps for the applicants: Director of Codes Marty Moseley will set up a meeting with the applicant
and C.J, Director of Planning to go over the comments and anticipated revisions. The application will
1
come back to the Planning Committee in August for a potential recommendation to the Town Board for
re-zoning. The Applicant would then apply to the Planning Board for a Special Permit before operating
permits could be issued.
5. Update: Tompkins Green Energy Network(TGEN) Master Implementation Plan. Rod reported
that a DER(distributed energy resources)plan was received and will go to the Town Board in August.
Initially it was anticipated that the Master Implementation Plan would come back to the Planning
Committee for review, however at this time it is solely the DER Plan that will go to the Town Board
with a memo from the Sustainability Planner to explain. The DER plan may need an additional meeting
for attorney review prior to town board adoption.
6. Update: City of Ithaca Draft Encampment Policy. A draft document and map were emailed to the
committee members prior to the meeting. The map was briefly shown on screen by a committee member
and appears to cover a city owned property within the town. It was suggested that Rod contact the city
and request a representative to briefly present and explain the draft policy to the town board.
7. Update: East Shore Drive Pedestrian and Bicyclist Safety Corridor Project. C.J. updated the
committee that the proposals for the R.O.W. survey/mapping (Erdman Anthony&Associates) and the
Feasibility Study(Barton&Loguidice)have been approved by the Town Board and a kickoff meeting
will be scheduled soon, noting multi agency and interdepartmental coordination needed as well. Funding
for the project was awarded by NYS Assemblymember Anna Kelles, who recently visited Town Hall in
person. It was mentioned that the project could be put on the town website for public awareness.
8. Update: Financial Feasibility Analysis of Residential Development or South Hill Traditional
Neighborhood Development(TND). C.J. updated that the (up to IOK) grant fund assistance application
from the County to offset the cost of this analysis was approved recently. There is a new affordable
housing scenario needed (if the County funding is accepted) which was not specifically written into the
Camoin Associates proposal/scope of work that was previously approved. C.J. asked the committee their
thoughts on requesting a revision to the Camoin Scope of work. The other option could be to decline the
funding from the County. Rich noted the desire for an effective outcome for the project if an additional
large piece or deliverable is added. The total cost of the study as previously approved was $19,500. C.J.
will reach out to Camoin to clarify if they will add the affordable housing piece to the current proposal
and report back to the committee as well as get more clarification with the county as to the desired
outcome of the additional piece and proposed draft language for the amendment to the scope.
9. Staff updates and reports.
Rod noted there has been some concern in the Village of Cayuga Heights over the marketing material for
the proposed sale of the RaNic Golf course. He asked if there were any Town concerns about the
wording or description of the proposed PDZ. Staff and committee members read the listing and although
approval of the PDZ and future plans are implied, the language describing where the project is in the
process is generally accurate and did not cause significant concern at this time. The existing zoning
possibilities and Town Comprehensive Plan language was briefly discussed.
C.J. updated that the Longview facility has been in contact for possible upgrades to their facility. Sewer
capacity in the area was mentioned and the owners will apply to the Planning Board once the details are
2
formalized. Tareyton Drive property-still awaiting information, water and sewer issues as well as park
land conveyance. Maplewood II is still being discussed,water connection with city or town and
upgrades needed to the water main to be determined. Southworks is hiring for a Development Services
Manager and an RFP is out for architectural services for the residential area in the town("The Woods")
as the first development focus-this will be a project that needs close coordination with the City of Ithaca
for infrastructure and other concerns. Potentially, the GEIS would need to re-opened if the new
development exceeds any previously approved thresholds.
11.Next meeting date and upcoming agenda items: August 17t', 2023 3:00 p.m. possible revised
LHCOD application for Hayt's Chapel and Schoolhouse.
The Town of Ithaca Planning Committee meeting concluded at 4:10 pm.
i
3
1296-1298 Trumansburg Road (Hayt's Chapel and Schoolhouse)
Request for Limited Historic Commercial Overlay District
Town of Ithaca, New York
August 9, 2023
Section 270-142.3 C(1): Narrative Description and Justification for Request
(a) Historical Significance:
Per section 270-142.3.B(1),the two buildings situated on Tax Parcel No. 24.4-2 qualify for
a LHC Overlay District by being listed in the New York State and National Registers of
Historic Places. The Chapel and Schoolhouse have been deemed of cultural and architectural
significance to local history and were listed in the State Register on April 25, 2005 (USNs:
10906.000292 and 10906.000293, respectively) and as a single place ("Hayt's Chapel and
Schoolhouse") in the National Register on December 22, 2005 (MAID: 75315064).
(b)Proposed limited commercial use and feasibility of using the buildings for this use:
Proposed Use: The owner(applicant)proposes to use the buildings for year-round unhosted
short-term rental use, subject to special permit review and approval, which is allowed in
LHC Overlay Districts as per § 270-142.4(2).
Feasibility: The buildings easily accommodate the proposed use without alteration. The
Chapel and Schoolhouse buildings each consist of a single large open living area with
separate kitchen, full bathroom, and laundry facilities.A portion of each of the living areas is
separated by partial walls to create a sleeping area. There is space sufficient for parking 2-3
vehicles near each building. The Schoolhouse has for years been used for long-term rental
and the Chapel building for short-term rental without incident.
(c) Compatibility with neighboring and nearby properties and uses
The proposed use blends well with the cemeteries, medical offices, and apartment buildings
that surround it. The property is bordered on two sides by Frear Memorial Park Cemetery
across Hayts Road to the northwest and Hayt's Cemetery (now West Hill Cemetery)
immediately west and southwest. There are medical offices across NYS Route 96
(Trumansburg Road)to its northeast. 200+ feet of woods separate it from an apartment
complex to its south and additional medical offices (housed in what was the Hayt family
home) to its southeast.
1
(d)How the proposal will facilitate the preservation and enhancement of the property
Establishment of the LHC Overlay District will allow the applicant to seek a special permit
from the Town of Ithaca Planning Board for certain low-impact special uses, especially
short-term rental use. The regular access between occupancies and additional income
afforded by this and other enabled uses will help ensure preservation of the historic integrity
of the buildings by facilitating needed restoration, repairs, and regular maintenance. It will
also permit more members of the public each year to appreciate the historic structures. Past
visitors have come to enjoy all that the surrounding area has to offer, or for work, or to visit
their children or attend a graduation at one of the nearby colleges, or to undergo treatments
or support hospitalized family members at Cayuga Medical Center just across the road.
Furthermore, the historical significance of the property (collected in a folder for guests to
read during their visit), especially its officially-recognized likely role in the Underground
Railroad, has inspired guests to look deeper into Ithaca's rich history of supporting basic
human rights, as evidenced by statements the applicants have received from past guests, such
as the following:
"I just read about the possibility that the church was part of the Underground
Railroad. That's amazing!... It's great that it's in the hands of someone who
appreciates its history."
2
Section 270-142.3 C(2): Conditions Assessment
NOTE: Please see the attached assessment report performed by certified property inspector
Lars Burggren of LB Spaces on June 11, 2023. The following text has been compiled by the
applicants,drawing from this report("Assessment"sections) as well as information gathered
from the National Register listing ("Description" sections).
Chapel Building
r f
3
View of original building, c.1900
I
t
s.
View of building as of July 2023
3
Overview
The original Hayt's Chapel building was constructed in 1847 as a rectangular single-story
mass measuring 24 feet by 36 feet and fronting on Trumansburg Road. The front elevation is
three bays wide with a center entrance flanked by windows. The side elevations have two
symmetrical pairs of windows. There is a small entrance vestibule addition at the front and a
shed-roofed addition at the rear of the building,both thought to have been constructed in the
1930s or 1940s when the building was converted to school use. A Town of Ithaca historical
marker in front of the Chapel on Trumansburg Road calls attention to the "Abolition
Church." The chapel was completely renovated with new roof and interior renovation
meriting a Tompkins County Historical Renovation Award in 2006.
VA
HAYTS CHAPEL
t BUILT• •
HILL. WAS KNOWN ABOLITION
CHURCH FOR THE ANTI. SLAVERY
ADVOCATES • LEADERS
a._ TOWN OF ITHACA
1996
f S Vt'
(a) Cladding materials, including trim, architectural details, and attachments:
Description: The front elevation features two projecting steeples (columns capped with
pyramidal pinnacles) flanking a central entrance and wall segment which is topped with a
crenellated parapet. This is consistent with the Gothic Revival style architecture that was
popular in the area during the mid-19th century. A rectangular attic vent rests on a crown
molding above the entrance. With the exception of the front vestibule addition, which is
sheathed in clapboards, the entire exterior of the building, including the rear addition, is
sheathed in random-width vertical wood planks that are laid flush with one another.
Assessment:Paint is chipping, missing and/orpeeling on front vestibule siding and along the
diagonal set baseboard.All siding is showing excess wear(damp and paint damage)near the
base due to splash back from roof drip edge. Paint is chipping and peeling throughout. The
steeples (columns and pinnacles) are chipping, missing and/or peeling paint, pest intrusion
observed and seams are showing signs of separation. One of the pinnacles is crooked and/or
detached. Repair to the damaged steeples is recommended. Thorough refinishing and
painting is recommended.Due to the heavy wear from sun and weather, regular maintenance
4
is recommended to ensure a solid surface coating on the wood steeples. Wood fascia boards
are showing signs of water damage,pest damage and peeling/chipped paint. Replacement of
fascia boards is recommended by a carpenter specializing in exterior trim. Fascia boards on
the rear shed roof are showing signs of water damage. It appears that there is a leak beneath
the roof covering causing excessive damage to the fascia boards. Problem solving the water
leak followed by repair and/or replacement of the damaged fascia boards recommended by a
carpenter specializing in exterior trim. It is recommended that all worn exterior surface
coverings be scraped/sanded, primed and painted within 0-3 years.
.aut exterior
— alp
I`
f <� rr -.
a �
.j
t NaQi ta3cia
5
(b) Windows and doors, including panes and trim:
Description:
Windows: The front elevation has single double-hung nine-over-nine sash windows flanking
the centered entrance. The side elevations have two pairs of double-hung nine-over-nine sash
windows. All windows on the front and side elevations are capped by a projecting Tudor
molding and have retained most of their original glass panes. There are random window
openings in the rear addition.
Doors: Metal screen door on front vestibule. Wood door on rear addition.
Assessment:
All nine-over-nine sash windows would benefit greatly through new window glazing,
refinishing, and repainting wood surfaces. Wood window trim is showing signs of
chipping/peeling paint,exposed bare wood, and light water damage throughout all surfaces.
Scraping/sanding, priming, and painting is recommended within 0-3 years.
. wtw,�
/, North window
ML J �
(c) Roof, including gutters and chimney:
Description:
Roof. The c.1900 photo above shows that the original roof was shingled. The present roof is
standing seam metal panel. The front vestibule addition has a gable roof with shingles. The
rear addition has a shed roof of standing seam metal panel.
Gutters: Not present
Chimney:A block chimney stack rises out of the rear addition and abuts the south corner of
the southwest wall of the main structure. It does not appear in the c.1900 photo.
There are solar panels on the southeast slope of the main structure's roof.
6
Assessment:
Roof. A section of metal roof(approximate age 20+years) on the north end has become
detached from possible ice damage. Repair to this area is recommended. The flashing near
the steeples was installed poorly and has become detached which will cause water intrusion
below the surface. Installation of new and/or repair to the existing flashing is recommended.
Plumbing vent at the west shed roof was not installed properly which may be contributing to
water leaks. Sealant and proper fastening is recommended.
Gutters: Not present but are highly recommended to be installed. Roof drip edge runoff can
cause excessive foundation settling, splash back against siding and foundation and possible
water intrusion into lower home levels (basement/crawlspace).
Chimney: The base of the chimney stack and flashing is deteriorating. Repair to base block
chimney surface and new flashing detail is recommended by a qualified stone mason.
iumns. r�
F ' 1 � r
y
pop-
(d) Decks,porches, and/or balconies: Not present
(e) Grounds specific to elements that are relevant to the historic integrity:
Description: A chain link fence encloses the property on three sides, likely originating when
the Chapel functioned as a schoolhouse (until as late as 1964).
Assessment:Trees and shrubs are overgrown and growing onto the siding and roof. This will
cause unwanted surface damage and possible pest and/or water intrusion. Tree branches are
recommended to be cut back off of the roof and away from any house surfaces. Shrubs are
recommended to be cut back at least 16 inches from any home surface.
7
Schoolhouse Building
- IF
■■■
View of original building, 1908
F
ram_ �II I I
1 � I
r--
View of building as of 2004
8
Overview
Hayt's Schoolhouse was constructed in the 1830s as a one story frame "T" shaped building in
the Greek Revival style. The one-room school remained in use until 1964. There is a shed-
roofed addition at the south end of the southwest elevation..
(a) Cladding materials, including trim, architectural details, and attachments:
Description: Wood plank cladding. Style is Greek Revival with cornice returns.
Assessment: Paint is chipping, missing and/or peeling throughout entire surface covering.
Rust is visible through paint from nails. It is recommended that all exterior surface coverings
be scraped/sanded, primed, and painted within 0-3 years.
Wood soffits are showing signs of cracking/peeling throughout entire surface. It is
recommended that all exterior surface coverings be scraped/sanded, primed, and painted
within 0-3 years.
9
�� North-Soffit
t
I �
i
i
Wood cornice is showing signs of water damage, rot, peeling/chipping paint, and separation
damage. It is recommended to replace all damaged wood, repair holes as needed with filler
(if applicable), prime, and paint surface. All repairs are recommended to be done before the
roof replacement by a carpenter specializing in exterior trim work.Near the chimney, there is
a section of cornice that has been damaged, rotted out and detached. Signs of pest intrusion
are observed. Immediate correction is recommended to prevent further pest and/or water
intrusion.
'`
^ , d '
10
(b) Windows and doors, including panes and trim:
Description:The front elevation with two wood doors and a pediment-shaped lintel over the
entrance are preserved as well as a semi-circular gable louver. The building had been
vandalized while unoccupied from 1964 to 1971.Except for two double-hung nine-over-nine
sash windows (on each side of south corner) all original windows had been destroyed and
were replaced with thermopane windows. The southwest addition also has a wood door.
Assessment:
Wood corner and window trims are showing signs of chipping/peeling paint, exposed bare
wood, and light water damage throughout all surfaces. Scraping/sanding, pruning, and
painting is recommended within 0-3 years. Nine-over-nine sash windows would benefit
greatly through new window glazing, refinishing, and repainting wood surfaces.
th
r
I ` i
window Vim
11
E n
d �
f�
-=� ./ 1
iT Ak
■■ --
(c) Roof, including gutters and chimney
Description:
Roof Gable. The 1908 photo shows that the original roof was shingled. The present roof is
standing seam metal panel. The southwest addition has a shed roof with asphalt shingle.
Gutters: Not present
Chimney: A block chimney stack rises out of the southwest addition and abuts the south
corner of the southwest wall.
Assessment:
Roof. Metal roof has reached the end of its useful life. Seams are rusted through, drip edge is
rusted out and damaged, rust and nail/screw holes are present throughout and rust and
peeling surface coating is present. A patch in the roof is observed. It appears this may have
been an old chimney stack cutout. Replacement is recommended within 0-1 years by a
qualified roofing contractor.
12
1 �
�� 1 Lam• � L.. _ — -_- - _._
Gutters: Not present but are highly recommended to be installed. Roof drip edge runoff can
cause excessive foundation settling, splash back against siding and foundation and possible
water intrusion into lower home levels (basement/crawlspace).
Chimney: Chimney stack,flashing,and flue cap are deteriorating. Repair to chimney surface
and new flashing and flue cap are recommended by a qualified stone mason.
(d) Decks,porches, and/or balconies: Not present
(e) Grounds specific to elements that are relevant to the historic integrity:
Assessment: A large tree branch has broken and is resting on the roof. Removal is
recommended to prevent further damage. Trees and shrubs are overgrown and
growing into the siding and roof. This will cause unwanted surface damage and
possible pest and/or water intrusion. Tree branches are recommended to be cut back
off of the roof and away from any house surfaces. Shrubs are recommended to be cut
back at least 16 inches from any home surface.
13
Section 270-142.3 C(3)(a): Preservation Plan
For Parts [1] and [2] below, owners will consult with professionals in historical preservation
prior to modifications. Any modifications would be made in a good faith effort to match
existing or earlier items/materials as they appear in the photos above. If such materials are
not available, materials that are closest in visual appearance,taking into account texture, size,
finish, color, and profile, should be used.
[11 Restoration and/or repair of identified deficiencies:
Within 1 Year:
• Cut tree branches and shrubs back at last 16 inches from both structures.
• Remove broken tree branch [Schoolhouse].
• Repair north eave of main structure to prevent additional water damage [Chapel].
• Repair eave of rear shed roof to prevent additional water damage [Chapel].
• Examine all eaves of both main structures and, if needed, make modifications to
accommodate runoff without adding gutters, which were not historically present.
Within 2 Years:
• Repair or remove chimneys on both structures (note: current chimneys were not part
of the original structures):
o [Schoolhouse] repair surface of chimney stack, replace flashing and flue cap.
o [Chapel] repair surface of chimney base block, replace flashing.
o [Both] Alternatively, replace chimneys with flue and flue cap to vent the
recently updated furnace.
• Replace damaged sections of cornice [Schoolhouse].
• Replace roof surface [Schoolhouse].
Within 3 Years:
• Repair or replace damaged sections of steeples (columns and pinnacles) [Chapel].
• Realign and secure crooked pinnacle [Chapel].
• Repair or replacement of damaged section of fascia boards [Chapel].
• All exterior wood surfaces [both buildings] to be scraped/sanded, primed, and
painted.
• Replace or repair flashing above front vestibule addition [Chapel].
[21 Long-term property maintenance, upkeep, changes, or additions:
• Regular trimming of branches and shrubs to maintain at least 16 inches between
vegetation and structures.
• Regular inspection and maintenance by owners of all exterior surfaces.
• Biennial inspection by Town officials per Section 270-142.3 C(3)(a)[3].
• Exterior inspection every 5 years by a design professional (architect, certified
building inspector, or civil/structural/architectural engineer)
14
[3] Landowner consent to enter the grounds for annual or biennial exterior
inspections:
I, Alexa Schmitz, grant consent to Town officials to enter the grounds at 1296-1298
Trumansburg Road for the purpose of conducting biennial inspections of the exterior
conditions of the structures located at that address, related to its rezoning to a Limited
Historic Commercial Overlay District per Section 210-142.3 of the Town of Ithaca Code. Per
Section 270-142.3 C(3)(a)[3] the Town shall provide advance written or verbal notification
to the property owner of the inspection.
JSignature: date: 9 August 2023
15
o¢e 5.e1MI71
,T ,
• +c S f s
cc °< )O
IM RV
SUKV
NAYT] S"00 'TRW i'�T'Y
IOCaT[D AT LC
C4) Ti°w OI T4UNAwMYRi R D s( Tf
1Y: + TO— oFi Tw CA. TO-1— CYYA1TY,tw1L :V2
"Survey Map Hayts School Property"dated August 13, 1965, prepared by Thomas G. Miller
s
Satellite image centered on Hayts Chapel and Schoolhouse (Image date: April 5, 2021)
16
i'
rf �
Inspection Report
Preparedfor: Alexa Schmitz
• • • iTrumansburg •
Ithaca, NY 14850
Inspected •
SpacesLars Burggren
LB
LB Spaces
Page 1 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Table of Contents
Definitions 2
General Information 2
Lots and Grounds 3
Exterior 4
Roof 9
Final Comments 11
Summary 12
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 2 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Definitions
NOTE:All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection
Acceptable Functional with no obvious signs of defect.
Not Present Item not present or not found.
Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible,or disconnected at time of
inspection.
Marginal Item is not fully functional and requires repair or servicing.
Defective Item needs immediate repair or replacement. It is unable to perform its intended function.
General Information
Property Information
Property Address: 1296-1298 Trumansburg Rd.
City: Ithaca State: NY Zip: 14850
Client Information
Client Name: Alexa Schmitz
Client Address: 308 Linn St
City: Ithaca State: NY Zip: 14850
Phone: 607-262-5420 Email: alexa.schmitz@gmail.com
Client 2 Norman Porticella
Phone: 607-435-5319 Email: normanporticella@gmail.com
Inspection Company
Inspector Name Lars Burggren
Company Name LB Spaces
Address: 25 Woodthrush Ln.
City: Brooktondale, State: NY Zip: 14817
Phone: (607)200-4208
Email: lars@lbspaces.com
Amount Due: 650 Amount Received: 650
Conditions
Others Present: None Property Occupied: Occupied
Estimated Age: 1830, 1850 Entrance Faces: East
Inspection Date: 07/10/2023
Start Time: 8:30 am End Time: 11:46 am
Utilities On: Not Applicable
Temperature: 77 F
Weather: Partly sunny Soil Conditions: Damp
Space Below Grade: Crawl Space
Building Type: Single family Garage: None
Water Source: NA How Verified:
Sewage Disposal: NA How Verified:
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 3 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Lots and Grounds
1. Defective Vegetation: Trees, Shrubs- 1298
- a large tree branch has broken and is resting on the roof. Removal is recommended to prevent
further damage.
-Trees and shrubs are overgrown and growing into the siding and roof. This will cause unwanted
surface damage and possible pest and/or water intrusion. Tree branches are recommended to be
cut back off of the roof and away from any house surfaces. Shrubs are recommended to be cut back
at least 16 inches from any home surface.
1296
--Trees and shrubs are overgrown and growing into the siding and roof. This will cause unwanted
surface damage and possible pest and/or water intrusion. Tree branches are recommended to be
cut back off of the roof and away from any house surfaces. Shrubs are recommended to be cut back
at least 16 inches from any home surface.
xi -east ;��. 1298-south
•
SOUL )Fri
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 4 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Exterior
1298 Exterior Surface
1. Defective Surface covering wood plank- Paint is chipping, missing and/or peeling throughout entire surface
covering. Rust is visible through paint from nails.
It is recommended that all exterior surface coverings be scraped/sanded, primed and painted within
0-3 years.
2. Marginal Soffit Wood - Soffit material showing signs of cracking/peeling throughout entire surface.
Scraping/sanding, primer and paint recommended within 0-3 years.
North-Soffit
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 5 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Exterior (Continued)
Soffit (continued)
"Vest Soffit
3. Defective Cornice Wood - Cornice is showing signs of water damage, rot, peeling/chipping paint and
separation damage. It is recommended to replace all damaged wood, repair holes as needed with
filler (if applicable), prime and paint surface. All repairs are recommended to be done before the
roof replacement by a carpenter specializing in exterior trim work.
Near the chimney, there is a section of cornice that has been damaged, rotted out and detached.
Signs of pest intrusion is observed. Immediate correction is recommended to prevent further pest
and/or water intrusion.
I
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 6 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Exterior (Continued)
4. Defective Trim Wood - Corner trim and window trim are showing signs of chipping/peeling paint, exposed
bare wood and light water damage throughout all surfaces.
Scraping/sanding, priming and painting is recommended within 0-3 years.
rth-window trim ¢ t-wirck tr
5. Acceptable Doors Wood
Ea l\� — a
dq0��
6. Marginal Windows 9 over 9 sash, thermopane- All 9 over 9 sash windows would benefit greatly through new
window glazing, refinishing and repainting wood surfaces.
1 Aff, ��,
=e
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 7 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Exterior (Continued)
Windows (continued)
1296 Exterior Surface
7. Defective Surface covering Horizontal wood plank, Vertical wood plank- Paint is chipping, missing and/or
peeling on front vestibule siding and along the diagonal set baseboard.
All siding is showing excess wear (damp and paint damage) near the base due to splash back from
roof drip edge. Paint is chipping and peeling throughout.
The steeples and columns are chipping, missing and/or peeling paint, pest intrusion observed and
seams are showing signs of separation. . One of the steeples is crooked and/or detached. Repair to
the damaged steeples is recommended. Thorough refinishing and painting is recommended. Due to
the heavy wear from sun and weather, regular maintenance is recommended to ensure a solid
surface coating on the wood steeples.
It is recommended that all worn exterior surface coverings be scraped/sanded, primed and painted
within 0-3 years.
yy East,exterioxa�
f 1
pest.Arusion
a
r Eke _
`:)Id
crook de
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 8 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Exterior (Continued)
Surface covering (continued)
8. Defective Fascia Wood - Fascia boards are showing signs of water damage, pest damage and
peeling/chipped paint. Replacement of fascia boards is recommended by a carpenter specializing in
exterior trim.
Fascia boards on rear shed roof are showing signs of water damage. It appears that there is a leak
beneath the roof covering causing excessive damage to the fascia boards. Problem solving the
water leak (see roof details) followed by repair and/or replacement of the damaged fascia boards
recommended by a carpenter specializing in exterior trim.
i
'th f North ,fascia
9. Defective Trim Wood - window trim is showing signs of chipping/peeling paint, exposed bare wood and light
water damage throughout all surfaces.
Scraping/sanding, priming and painting is recommended within 0-3 years.
Al 3
\ -,
—. North window
North
window trim
10. Acceptable Doors Screen door/wood
11. Marginal Windows 9 over 9 sash - All 9 over 9 sash windows would benefit greatly through new window
glazing, refinishing and repainting wood surfaces.
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 9 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Exterior (Continued)
Windows (continued)
Roof
1298 Roof Surface
1. Method of Inspection: Ground level, Ladder at eaves, On roof
2. Defective Material: Metal, Asphalt shingle- Metal roof has reached the end of its useful life. Seams are rusted
through, drip edge is rusted out and damaged, rust and nail/screw holes are present throughout and
rust and peeling surface coating is present.
A patch in the roof is observed. It appears this may have been an old chimney stack cutout.
Replacement is recommended within 0-1 years by a qualified roofing contractor.
k �
3. Type: Gable, Shed
4. Approximate Age: Metal - 50 + years, Asphalt- 10-14 years
1296 Roof Surface
5. Method of Inspection: Ladder at eaves
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 10 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Roof (Continued)
6. Marginal Material: Metal - A section of roof on the north end has become detached from possible ice
damage. Repair to this area is recommended.
The flashing near the steeples was installed poorly and has become detached which will cause
water intrusion below the surface. Installation of new and/or repair to the existing flashing is
recommended.
Plumbing vent at the west shed roof was not installed properly which may be contributing to water
leaks. Sealant and proper fastening is recommended.
possible ice damage etacy/
eple columns _
i
7. Type: Gable
S. Approximate Age: 20 + years
9. Not Present Gutters: Not present- Gutters are not present on either property but are highly recommended for
both to be installed. Roof drip edge runoff can cause excessive foundation settling, splash back
against siding and foundation and possible water intrusion into lower home
levels(basement/crawlspace).
1298 Chimney
10. Defective Chimney: Block- Chimney stack, flashing and flue cap is deteriorating. Repair to chimney surface,
new flashing and flue cap is recommended by a qualified stone mason.
l
1296 Chimney
11. Defective Chimney: Block- The base of the chimney stack and flashing is deteriorating. Repair to base block
chimney surface and new flashing detail is recommended by a qualified stone mason.
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 11 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Roof (Continued)
Chimney: (continued)
r�
Final Comments
Based on the age of the home, Lead paint may be present. Please visit the following link below for more information
regarding this hazardous material.
https://www.epa.gov/lead/protect-your-family-lead-your-home-real-estate-disclosure
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 12 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Marginal Summary
This summary is not the entire report.The complete report may include additional information of concern to the client. It is recommended
that the client read the complete report.
Exterior
1. 1298 Exterior Surface Soffit Wood - Soffit material showing signs of cracking/peeling throughout entire surface.
Scraping/sanding, primer and paint recommended within 0-3 years.
2. 1298 Exterior Surface Windows 9 over 9 sash, thermopane- All 9 over 9 sash windows would benefit greatly
through new window glazing, refinishing and repainting wood surfaces.
3. 1296 Exterior Surface Windows 9 over 9 sash - All 9 over 9 sash windows would benefit greatly through new
window glazing, refinishing and repainting wood surfaces.
Roof
4. 1296 Roof Surface Material: Metal - A section of roof on the north end has become detached from possible ice
damage. Repair to this area is recommended.
The flashing near the steeples was installed poorly and has become detached which will cause water intrusion
below the surface. Installation of new and/or repair to the existing flashing is recommended.
Plumbing vent at the west shed roof was not installed properly which may be contributing to water leaks. Sealant
and proper fastening is recommended.
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 13 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Defective Summary
This summary is not the entire report.The complete report may include additional information of concern to the client. It is recommended
that the client read the complete report.
Lots and Grounds
1. Vegetation:Trees, Shrubs- 1298
-a large tree branch has broken and is resting on the roof. Removal is recommended to prevent further damage.
-Trees and shrubs are overgrown and growing into the siding and roof. This will cause unwanted surface damage
and possible pest and/or water intrusion. Tree branches are recommended to be cut back off of the roof and away
from any house surfaces. Shrubs are recommended to be cut back at least 16 inches from any home surface.
1296
--Trees and shrubs are overgrown and growing into the siding and roof. This will cause unwanted surface damage
and possible pest and/or water intrusion. Tree branches are recommended to be cut back off of the roof and away
from any house surfaces. Shrubs are recommended to be cut back at least 16 inches from any home surface.
Exterior
2. 1298 Exterior Surface Surface covering wood plank- Paint is chipping, missing and/or peeling throughout entire
surface covering. Rust is visible through paint from nails.
It is recommended that all exterior surface coverings be scraped/sanded, primed and painted within 0-3 years.
3. 1298 Exterior Surface Cornice Wood - Cornice is showing signs of water damage, rot, peeling/chipping paint and
separation damage. It is recommended to replace all damaged wood, repair holes as needed with filler (if
applicable), prime and paint surface. All repairs are recommended to be done before the roof replacement by a
carpenter specializing in exterior trim work.
Near the chimney, there is a section of cornice that has been damaged, rotted out and detached. Signs of pest
intrusion is observed. Immediate correction is recommended to prevent further pest and/or water intrusion.
4. 1298 Exterior Surface Trim Wood - Corner trim and window trim are showing signs of chipping/peeling paint,
exposed bare wood and light water damage throughout all surfaces.
Scraping/sanding, priming and painting is recommended within 0-3 years.
5. 1296 Exterior Surface Surface covering Horizontal wood plank, Vertical wood plank- Paint is chipping, missing
and/or peeling on front vestibule siding and along the diagonal set baseboard.
All siding is showing excess wear (damp and paint damage) near the base due to splash back from roof drip edge.
Paint is chipping and peeling throughout.
The steeples and columns are chipping, missing and/or peeling paint, pest intrusion observed and seams are
showing signs of separation. . One of the steeples is crooked and/or detached. Repair to the damaged steeples is
recommended. Thorough refinishing and painting is recommended. Due to the heavy wear from sun and weather,
regular maintenance is recommended to ensure a solid surface coating on the wood steeples.
It is recommended that all worn exterior surface coverings be scraped/sanded, primed and painted within 0-3
years.
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech
LB Spaces
Page 14 of 14 Alexa Schmitz
01:26 July 12, 2023 1296-1298 Trumansburg Rd.
Defective Summary (Continued)
6. 1296 Exterior Surface Fascia Wood - Fascia boards are showing signs of water damage, pest damage and
peeling/chipped paint. Replacement of fascia boards is recommended by a carpenter specializing in exterior trim.
Fascia boards on rear shed roof are showing signs of water damage. It appears that there is a leak beneath the
roof covering causing excessive damage to the fascia boards. Problem solving the water leak (see roof details)
followed by repair and/or replacement of the damaged fascia boards recommended by a carpenter specializing in
exterior trim.
7. 1296 Exterior Surface Trim Wood - window trim is showing signs of chipping/peeling paint, exposed bare wood
and light water damage throughout all surfaces.
Scraping/sanding, priming and painting is recommended within 0-3 years.
Roof
8. 1298 Roof Surface Material: Metal, Asphalt shingle- Metal roof has reached the end of its useful life. Seams are
rusted through, drip edge is rusted out and damaged, rust and nail/screw holes are present throughout and rust
and peeling surface coating is present.
A patch in the roof is observed. It appears this may have been an old chimney stack cutout.
Replacement is recommended within 0-1 years by a qualified roofing contractor.
9. 1298 Chimney Chimney: Block- Chimney stack, flashing and flue cap is deteriorating. Repair to chimney surface,
new flashing and flue cap is recommended by a qualified stone mason.
10. 1296 Chimney Chimney: Block- The base of the chimney stack and flashing is deteriorating. Repair to base block
chimney surface and new flashing detail is recommended by a qualified stone mason.
Palm-Tech Inspector, Copyright© 1998-2023, Palm-Tech