HomeMy WebLinkAbout12b Megapack_2_XL_Compliance_Summary Tesla Energy Products
Product: Megapack 2 XL
Last Revised: November 24, 2025
Revision 3.4
T=SLn
MEGAPACK 2 XL COMPLIANCE SUMMARY
This summary documents the available listings for Megapack 2 XL and Megapack 2 XL's main subcomponents.
If a certain standard is not listed below, it is a listing to which Megapack 2 XL will not be certified or that has
not yet been added to the Megapack 2 XL certification plan. All certificates to these standards are made
available in the Megapack 2 XL Compliance Packet on the Tesla Partner Portal. Contact your Tesla
representative for more information.
Cell
Standard Description Filename or Status
Standard for Batteries for Use in Stationary,
ANSI/CAN/UL 1973 Vehicle Auxiliary Power and Light Electric Rail Certified
(LER) Applications
UL 1642 Standard for Lithium Batteries Certified
Secondary cells and batteries containing alkaline
IEC 62619 or other non-acid electrolytes — Safety Megapack_2_XL—EU—CE—Safety_
requirements for secondary lithium cells and EMC.pdf
batteries for use in industrial applications
UN38.3 Transportation Testing for Lithium Batteries Certified
CONFIDENTIAL INFORMATION— SHARED UNDER NDA ONLY Page 1 of 8
MEGAPACK 2 XL COMPLIANCE SUMMARY
Battery Module
Standard Description Filename or Status
M egapac k-2—a nd—X L—Battery—M
odule—NA—UL1973.pdf — for
C010 and C011 cell option
Standard for Batteries for Use in Stationary, C012—Megapack-2—XL—Battery—
ANSI/CAN/UL 1973 Vehicle Auxiliary Power and Light Electric Rail Module—NA—UL1973.pdf — for
(LER) Applications C012 cell option
Supporting Document:
Megapack-2—XL—VoC—Ratings—Co
nfigurability.pdf
Secondary cells and batteries containing alkaline
IEC 62619 or other non-acid electrolytes — Safety Megapack-2—XL—EU—CE—Safety—
requirements for secondary lithium cells and EMC.pdf
batteries for use in industrial applications
UN38.3 Transportation Testing for Lithium Batteries Certified
UL 1998 Standard for Software in Programmable Evaluated to, as part of general
Components UL certification
Automatic electrical controls for household and Evaluated to, as part of general
IEC 60730 Annex H similar use - Requirements for electronic IEC certification
controls
CONFIDENTIAL INFORMATION— SHARED UNDER NDA ONLY Page 2 of 8
MEGAPACK 2 XL COMPLIANCE SUMMARY
System
Standard Description Filename or Status
Australian Standard Allows Megapack 2 XL to be lifted and
AS4991-2004 transported within Australia Megapack_2_XL_AS4991-2004.pdf
Lifting Devices
EU Battery Regulation (EU) 2023/1542 of the European Tesla_EU_Article_10_Documentation.
Regulation Article Parliament and of the Council of 12 July pdf
10 2023
United Kingdom - Applicable security requirements specified
Statement of in Schedule 1 of the Product Security and Tesla_Manufacturer_Statement_of_C
compliance for Telecommunications Infrastructure ompliance_for_Consumer_loT_Securi
consumer internet
of things (IoT) (Security Requirements for Relevant ty_UK-EN.pdf
security Connectable Products) Regulations 2023
Allows designs for using Megapack 2 XL
Megapack 2 XL DSA with pre-approved structural foundations Megapack-2—XL DSA—Pre-
Pre-Check - and anchorages in construction projects Check_California.pdf
California within the California Division of the State
Architect's (DSA) jurisdiction
US Virgin Islands Water and Power
US VI Water and Authority Requirements and procedures for Mega pack_2_XL_USVI_WAPA—Letter
Power Authorities interconnection generating facilities to the pdf
electrical distribution system
FDNY TM-2 Approval of Outdoor Stationary Storage Tesla_Megapack_2_XL_FDNY_Certifi
Battery Systems cate_of_Approval.pdf
NOM-024-SCFI- Commercial Information for packaging, Megapack_2_and_XL_NA_Mexico_N
2013 instructions and guarantees of electronic, OM-024_Letter.pdf
electric and electrical domestic products
Electronic Apparatus. Electronic household
NOM-001-SCFI- appliances input by different electric power Megapack_2_XL_NA_Mexico_NOM-
2018 sources. Safety requirements and testing 001_Letter.pdf
methods for type approval
IEEE 2030.5 IEEE Standard for Smart Energy Profile Megapack_2_and_XL_IEEE2030.5_C
Application Protocol SIP.pdf
CSIP Common Smart Inverter Profile Megapack_2_and_XL_IEEE2030.5_C
SIP.pdf
Decree of the Netherlands Authority for
Consumers and Markets of 21 April 2016,
Netherlands reference ACM/DE/2016/202151, Megapack_2_and_XL_VoC_Netherlan
concerning the determination of the ds.pdf
conditions as referred to in Article 31 of the
Electricity Act 1998 (Electricity Grid Code)
SRD 2.0 Hawaiian Electric IEEE 1547.1-2020 Source Megapack_2_and_XL_VoC_SRD_2.0.
Requirements Document Version 2.0 pdf
CONFIDENTIAL INFORMATION— SHARED UNDER NDA ONLY Page 3 of 8
MEGAPACK 2 XL COMPLIANCE SUMMARY
Standard Description Filename or Status
Megapack_2_and_XL_Japan_Type_Te
st—Report-60Hz.pdf
Japan Type Test Japan Electrical Testing (JET) Type Test
Report Report for Energy Storage Systems
Megapack_2_and_XL_Japan_Type_Te
st—Report-50Hz.pdf
Inverters, Converters, Controllers And
Interconnection System Equipment For Use Megapack_2_and_XL_VoC_UL_1741_
UL 1741 PCS With Distributed Energy Resources - Power PCS.pdf
Control Systems (PCS) - Certification
Requirement Decision 3/8/2019
Megapack_2_XL_NA_UL9540_UL174
1—CSA—C22-2-107-1.pdf — for cell
option C010 and C011
Standard for Energy Storage Systems and C012—Megapack-2—XL—NA—UL9540—
ANSI/CAN/UL 9540 Equipment UL1741_CSA_C22-2_107-1.pdf — for
cell option C012
Supporting Document:
Megapack-2—XL—VoC—Ratings—Confi
gurability.pdf
UL9540A/Megapack_2_and_XL_-
ANSI-
UL_9540A_Unit_Level_Report.pdf —
Test Method for Evaluating Thermal for cell option C010 and C011
UL 9540A Runaway Fire Propagation in Battery Energy
Storage Systems UL9540A/CO12_UL954OA_Megapack
_2_XL_-_ANSI-
UL_9540A_Unit_Level_Re port.pdf —
for cell option C012
Megapack_2_XL_NA_UL9540_UL174
Standard for Inverters, Converters,
1—CSA—C22-2-107-1.pdf
UL 1741 Controllers and Interconnection System
Equipment for Use With Distributed Energy
Resources Supporting Document:
Megapack_2_XL_VoC_Ratings_Confi
gurability.pdf
Directive on the harmonization of the laws of
Low Voltage the Member States relating to the making Megapack_2_XL_EU_CE_Safety_EMC
Directive available on the market of electrical pdf
2014/35/EU equipment designed for use within certain
voltage limits
Directive on the harmonization of the laws of
Electro Magnetic the Member States relating to Megapack_2_XL_EU_CE_Safety_EMC
Compatibility electromagnetic compatibility pdf
CONFIDENTIAL INFORMATION— SHARED UNDER NDA ONLY Page 4 of 8
MEGAPACK 2 XL COMPLIANCE SUMMARY
Standard Description Filename or Status
Directive
2014/30/EU
CSA C22.2 NO Standard for Power Conversion equipment Megapack-2-XL-NA-UL9540-UL174
107.1 1-CSA-C22-2-107-1.pdf
Electrical energy storage (EES) systems - Megapack_2_XL_IEC 62933-5-2.pdf
IEC 62933-5-2 Part 5-2: Safety requirements for grid-
integrated EES systems - Electrochemical-
based systems Megapack_2_XL_EU_CE_Safety_EMC
.pdf
UL/CAN/IEC 62109- Safety of power converters for use in Megapack-2-XL-EU-CE-Safety-EMC
1 photovoltaic power systems - Part 1: pdf
General requirements
IEEE Recommended Practice and Evaluated to, as part of IEEE 1547
IEEE 519 Requirements for Harmonic Control in certification
Electric Power Systems
Electromagnetic compatibility (EMC) - Part Megapack-2-XL-EU-CE-Safety-EMC
EN 61000-6-2 6-2: Generic standards - Immunity for pdf
industrial environments
Electromagnetic compatibility (EMC) - Part Megapack_2_XL_EU_CE_Safety_EMC
EN 61000-6-4 6-4: Generic standards - Emission standard pdf
for industrial environments
Industrial, Scientific and medical equipment
EN 55011 - Radio frequency disturbance Megapack-2-XL-EU-CE-Safety-EMC
characteristics - Limits and methods of pdf
measurement
Electromagnetic compatibility (EMC) - Part
3-11: Limits - Limitation of voltage changes,
EN 61000-3-11 voltage fluctuations and flicker in public Megapack-2-XL-EU-CE-Safety_EMC
low-voltage supply systems - Equipment pdf
with rated current <- 75 A and subject to
conditional connection
Electromagnetic compatibility (EMC) - Part
3-12: Limits - Limits for harmonic currents Megapack-2-XL-EU-CE-Safety-EMC
IEC 61000-3-12 produced by equipment connected to public pdf
low-voltage systems with input current
>16A and <<-75A per phase
IEEE 693 IEEE Recommended Practice for Seismic Megapack-2-XL-VoC-IEEE-693.pdf
Design of Substations
Megapack-2-XL-NA-UL9540-UL174
IEEE Standard for Interconnection and 1-CSA-C22-2-107-1.pdf
IEEE 1547 Interoperability of Distributed Energy
Resources with Associated Electric Power
Systems Interfaces Megapack-2-and-XL-DoC-IEEE1547
_LROV.pdf
CONFIDENTIAL INFORMATION- SHARED UNDER NDA ONLY Page 5 of 8
MEGAPACK 2 XL COMPLIANCE SUMMARY
Standard Description Filename or Status
Standard for Inverters, Converters,
UL 1741 SB Controllers and Interconnection System Megapack-2—XL—NA—UL9540—UL174
Equipment for Use with Distributed Energy 1—CSA—C22-2-107-1.pdf
Resources — Supplement B
Megapack-2—XL—U K—G99—Amd
United Kingdom — Requirements for the connection of 8—Form A2-3.pdf
G99 Issue 1 generation equipment in parallel with public
Amendment 8 distribution networks on or after 27 April
2019 Megapack-2—XL—U K—G99—Amd
8—Form B—C—D.pdf
Netherlands - Electricity grid code concerning the
ACM/DE/2016/2021 determination of the conditions of Megapack-2—and—XL—VoC—Netherlan
51 connection as referred to in Article 31 of the ds.pdf
Netherland's Electricity Act 1998
Slovenia — Approval of the proposals for the non- Megapack-2—and—XL—VoC—Slovenia.
Commission exhaustive requirements of Commission pdf
Regulation 2016/631 Regulation 2016/631
Requirements for generating plants to be
connected in parallel with distribution Megapack-2—and—XL—VoC—EN50549
EN 50549-1 networks - Part 1: Connection to a LV pdf
distribution network - Generating plants up
to and including Type B
Requirements for generating plants to be
connected in parallel with distribution Megapack-2—and—XL—VoC—EN50549
EN 50549-2 networks - Part 2: Connection to a MV pdf
distribution network - Generating plants up
to and including Type B
Requirements for generating plants to be Megapack-2—and—XL—VoC—EN50549
EN 50549-10 connected in parallel with distribution pdf
networks Tests for conformity assessment
of generating units
CONFIDENTIAL INFORMATION- SHARED UNDER NDA ONLY Page 6 of 8
MEGAPACK 2 XL COMPLIANCE SUMMARY
Tesla System Controller
Standard Description Filename
China State Radio Monitoring and Testing Control ler_1471208_China_SR RC.pdf
SRRC Center — SRRC Certification
Certification to IEEE 2030.5-2018 networking Controller—GLOBAL—IEEE2030-5.pdf
CSIP IEEE 2030.5 standard in the manner described in the
Common Smart Inverter Profile
Safety Requirements for Electrical Equipment Control ler1471208—NA—CSA-22-
IEC / EN / UL 2_UL-61010-1.pdf,
61010-1 for Measurement, Control, and Laboratory Controller1471208 APAC EMEA IEC-
Use - Part 1: General Requirements — — —
61010-1.pdf
CAN/CSA-C22.2 Safety Requirements For Electrical Equipment Control ler1471208—NA—CSA-22-
No. 61010 - 1-12 + For Measurement, Control, And Laboratory 2_UL-61010-1.pdf
Gil + GI2 Use - Part 1: General Requirements
CONFIDENTIAL INFORMATION— SHARED UNDER NDA ONLY Page 7 of 8
MEGAPACK 2 XL COMPLIANCE SUMMARY
Manufacturing
Standard Description Filename
Quality Management System applicable to Megafactory_Lathrop_ISO_9001_Certifica
ISO 9001:2015 Manufacturing of Industrial Energy Storage tion.pdf
Products (Lathrop, CA, USA)
Quality Management System applicable to Megafactory_Shanghai_ISO_9001_Certifi
ISO 9001:2015 Manufacturing of Industrial Energy Storage cation_en-US.pdf
Products (Shanghai, China)
Quality Management System applicable to Megafactory_Shanghai—ISO_9001_Certifi
ISO 9001:2015 Manufacturing of Industrial Energy Storage cation_zh-CN.pdf
Products (Shanghai, China)
CONFIDENTIAL INFORMATION— SHARED UNDER NDA ONLY Page 8 of 8