Loading...
HomeMy WebLinkAbout13 - Groton Solar 2 CIVIL DrawingsSOUTH SITE SITE:SOUTH MAIN STREET, EXT. GROTON, NY 13073 TM #: 31-1-12.1 LOT AREA: 58.73 AC P.W. GROSSER CONSULTING, INC. 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC NY GROTON II (SOUTH MAIN STREET), LLC SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR PROJECT 4.0 MW AC GROTON, NEW YORK ENGINEER: P.W. GROSSER CONSULTING, INC. 630 JOHNSON AVENUE, SUITE 7, BOHEMIA, NY 11716 TEL: (631) 589-6353 FAX: (631) 589-8705 TOWN: TOWN OF GROTON 108 E CORTLAND STREET GROTON, NY 13073 COUNTY: TOMPKINS COUNTY 320 N TIOGA STREET ITHACA, NY 14850 TEL (607) 274-5431 PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 0 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 1 8 p m B y : r v a u g h n PLANS PROJECT CONTACTS MUNICIPAL CONTACTS SITE INFORMATION SHEET INDEX CLIENT INFORMATION CLIENT: NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 COVER SHEET 1 OF 19 VICINITY MAP SCALE: 1"=2500' FOR CONSTRUCTION ISSUED FOR: CONSTRUCTION ISSUE DATE: 07/03/2025 LAST REVISED: 07/03/2025 SCALE: 1" = 2500' 0 2500 5000 SOURCE: NEW YORK STATE GIS RESOURCES NORTH SITE NO.SHEET TITLE 01 C-000 COVER 02 C-001 GENERAL NOTES AND LEGEND INFORMATION 03 C-100 EXISTING CONDITIONS PLAN 04 C-200 SITE LAYOUT PLAN 05 C-300 GRADING AND DRAINAGE PLAN 06 C-400 ACCESS ROAD PLAN AND PROFILE STA 0+00 TO STA 4+00 07 C-401 ACCESS ROAD PLAN AND PROFILE STA 4+00 TO STA 8+00 08 C-402 ACCESS ROAD PLAN AND PROFILE STA 8+00 TO STA 11+24.98 09 C-403 ACCESS ROAD PLAN AND PROFILE STA 11+24.98 TO STA 14+50 10 C-404 ACCESS ROAD PLAN AND PROFILE STA 14+50 TO STA 17+03 11 C-500 EROSION AND SEDIMENT CONTROL PLAN 12 C-600 PHASING PLAN 13 C-700 LANDSCAPING PLAN 14 C-800 PRIME SOILS IMPACT PLAN 15 C-900 SITE DETAILS 16 C-901 EROSION AND SEDIMENT CONTROL DETAILS 17 C-902 DRAINAGE DETAILS 18 C-903 EQUIPMENT SPECIFICATION 19 C-904 OVERHEAD ELECTRICAL DETAILS BASEMAP NOTES 1.EXISTING CONDITIONS BASEMAP INFORMATION IS BASED ON LIDAR FROM NYS GIS DATA DOWNLOADED ON 11-15-23. 2.EXISTING TOPOGRAPHY WITHIN FENCED AREA IS BASED ON A SURVEY BY BULLROCK SOLAR. SURVEY FILE DATED 3-24-2025. 3.PROPOSED SOLAR DEVELOPMENT LAYOUT INFORMATION IS BASED ON CONCEPTUAL LAYOUT PLAN DEVELOPED BY BULLROCK SOLAR, DATED 04-07-25. ALL BASEMAP INFORMATION IS TO BE CONSIDERED APPROXIMATE AND IS TO BE FIELD VERIFIED BY A NEW YORK STATE LICENSED SURVEYOR PRIOR TO FINALIZING DESIGN. 4.LOT LINES BASED ON INFORMATION PROVIDED FROM NYS GIS; DOWNLOADED ON 11-15-23. WETLANDS NOTES 1.ACTUAL LIMITS OF ALL STREAMS, WETLANDS AND WETLAND ADJACENT AREAS ARE TO BE FIELD VERIFIED VIA SURVEY AND WILL BE MARKED IN THE FIELD BY SURVEY MARKERS, RIBBON, FLAGS, OR EQUIVALENT PRIOR TO START OF CONSTRUCTION. 2.EFFORTS SHALL BE MADE TO MINIMIZE DISTURBANCE TO ANY STATE OR FEDERALLY REGULATED WETLANDS. UNNECESSARY REMOVAL OF VEGETATION OR DEGRADATION ALONG STREAM BANKS IS PROHIBITED. 3.ONLY HAND CLEARING SHALL BE ALLOWED IN WETLAND AREAS AS NECESSARY. MACHINE CLEARING IS PROHIBITED WITHIN WETLAND AREAS. 4.IF TEMPORARY ACCESS IS REQUIRED IN WETLAND AREAS, TEMPORARY TIMBER MATS WILL BE USED TO MINIMIZE DISTURBANCE TO UNDERLYING WETLAND SOILS. 5.STAGING OF ANY CONSTRUCTION MATERIALS OR EQUIPMENT IS PROHIBITED IN WETLAND AREAS. 6.ANY WETLAND DISTURBANCE IS TO BE RESTORED WITH APPROPRIATE WETLAND SEED MIX IN ACCORDANCE WITH NYSDOT ITEM 203.01920007 OR MOST CURRENT NYSDEC REQUIREMENTS RELATED TO WETLAND RESTORATION. COMPONENT OF THE SEED MIX MAY BE SUBSTITUTED WITH THE ENGINEER'S APPROVAL. GENERAL NOTES 1.CONTRACTOR WILL BE RESPONSIBLE TO FIELD VERIFY ALL EXISTING CONDITIONS AND SITE FEATURES PRIOR TO CONSTRUCTION. ANY DISCREPANCIES FOUND SHALL BE DOCUMENTED IN WRITING AND SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. 2.CONTRACTOR WILL BE RESPONSIBLE TO LOCATE AND MARK OUT ALL EXISTING UTILITIES, INCLUDING THOSE UNDERGROUND, PRIOR TO CONSTRUCTION. ANY POTENTIAL INTERFERENCES WITH PROPOSED FEATURES SHALL BE DOCUMENTED IN WRITING AND SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. 3.THE CONTRACTOR SHALL PROTECT ALL EXISTING SITE FEATURES AND UTILITIES THAT ARE NOT DESIGNATED FOR REMOVAL. ANY SITE FEATURE, UTILITY, STREET APPURTENANCE, OR OTHER ITEM THIS IS DAMAGED BY THE CONTRACTOR OR ITS SUBCONTRACTORS DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED IN-KIND BY THE CONTRACTOR, AS DETERMINED BY THE OWNER OR ENGINEER, AT NO ADDITIONAL COST TO THE OWNER. 4.CONTRACTOR WILL BE REQUIRED TO OBTAIN ANY ADDTIONAL PERMITS REQUIRED TO DO THE WORK OR DELIVER MATERIALS TO THE SITE THAT ARE NOT PROVIDED BY THE OWNER OR ENGINEER. ALL WORK WITHIN AN EXISTING RIGHT-OF-WAY WILL REQUIRE PERMITTING WITH RESPECTIVE OWNER, STATE OR COUNTY AGENCY, TOWN DEPARTMENT OF PUBLIC WORKS, OR HIGHWAY DEPARTMENT AS APPLICABLE. SURVEY NOTES EROSION AND SEDIMENT CONTROL NOTES 1.ALL EROSION CONTROL MEASURES SHALL BE INSTALLED IN ACCORDANCE WITH NEW YORK STANDARDS AND SPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL (BLUE BOOK), AND LOCAL GOVERNING SOIL AND WATER CONSERVATION DISTRICT STANDARDS. THE EROSION AND SEDIMENT CONTROLS SHOWN ON THESE PLANS AND AS DESCRIBED IN THE PROJECT SWPPP REPRESENT THE MINIMUM REQUIREMENTS AND ADDITIONAL EROSION AND SEDIMENT CONTROLS MAY BE REQUIRED BASED ON CONDITIONS ENCOUNTERED IN THE FIELD. CONTRACTOR WILL BE RESPONSIBLE FOR ENSURING PROJECT REMAINS IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS AND STANDARDS PERTAINING TO EROSION AND SEDIMENT CONTROLS. 2.EROSION AND SEDIMENT CONTROLS WILL BE INSTALLED PRIOR TO ANY EARTH DISTURBING ACTIVITIES AND WILL BE MAINTAINED FOR THE DURATION OF THE WORK, INCLUDING TEMPORARY CONSTRUCTION SWALES AND DETENTION POND WITH OUTLET STRUCTURE AND ROCK OUTLET PROTECTION. 3.CONTRACTOR WILL UTILIZE MEANS, METHODS AND SEQUENCING THAT MINIMIZE THE AMOUNT OF EARTH DISTURBANCE TO THE EXTENT PRACTICAL, AND NOT TO EXCEED MORE THAN 5.0 ACRES AT ANY GIVEN TIME. 4.CONTRACTOR SHALL PROTECT ALL ON-SITE, ADJACENT AND/OR DOWNSTREAM STORM/SANITARY SEWERS, AND/OR OTHER WATER COURSES FROM CONTAMINATION BY WATER BORNE SILTS, SEDIMENTS, FUELS, SOLVENTS, LUBRICANTS OR OTHER POLLUTANTS ORIGINATING FROM THE SITE OR WORK BEING PERFORMED. 5.CONTRACTOR WILL FOLLOW GOOD HOUSEKEEPING AND SPILL CONTROL PRACTICES DURING SITE ACTIVITIES TO MINIMIZE STORMWATER CONTAMINATION FROM CONCRETE, PETROLEUM PRODUCTS AND WASTE MATERIALS. NO WET OR FRESH CONCRETE, LEACHATE OR WASHINGS FROM EQUIPMENT SHALL BE ALLOWED TO MIGRATE INTO EXISTING STORM/SANITARY SEWERS, DITCHES OR OTHER WATERS OF NEW YORK STATE. 6.ALL EXCAVATED OR IMPORTED MATERIAL STOCKPILES SHALL BE SUITABLY STABILIZED AND SURROUNDED BY SILT FENCE TO MINIMIZE POTENTIAL FOR SEDIMENT LADEN RUNOFF DISCHARGING TO DOWNSTREAM AREAS OR DRAINAGE FEATURES. DISTURBED SOILS OR STOCKPILES THAT ARE TO BE EXPOSED FOR MORE THAN 14 CALENDAR DAYS SHALL BE TEMPORARY STABILIZED WITH SEED MIX CONSISTING OF RYEGRASS (ANNUAL OR PERENNIAL) APPLIED AT 30 LBS PER ACRES (0.7 LBS PER 1,000 SQ. FT.), OR CERTIFIED "AROOSTOOK" WINTER RYE (CEREAL RYE) APPLIED AT 100 LBS PER ACRES (2.5 LBS PER 1,000 SQ. FT.) IF SEEDING IN OCTOBER OR NOVEMBER 7.CONTRACTOR MATERIAL AND EQUIPMENT STAGING AREAS AND CONSTRUCTION ENTRANCE LOCATIONS SHALL BE COORDINATED WITH THE OWNER PRIOR TO START OF CONSTRUCTION. CONSTRUCTION ENTRANCES AS SHOWN ON THE PLANS MAY BE MODIFIED BY THE CONTRACTOR WITH PRIOR APPROVAL FROM THE OWNER AND ENGINEER. 8.ALL EXISTING OR NEWLY INSTALLED CATCH BASINS/DRAINAGE INLETS SHALL HAVE DROP INLET PROTECTION INSTALLED THROUGHOUT THE DURATION OF CONSTRUCTION TO PREVENT SEDIMENTATION FROM ENTERING THE STORM SYSTEM. CONTRACTOR SHALL MAINTAIN OR REPLACE DROP INLET PROTECTION WHEN SIGNIFICANT SEDIMENT BUILDUP IS OBSERVED OR IS NOT FUNCTIONING CORRECTLY. 9.CONTRACTOR SHALL TAKE ALL NECESSARY AND APPROPRIATE MEASURES TO MITIGATE OR PREVENT FUGITIVE DUST THROUGHOUT THE DURATION OF CONSTRUCTION. CONTRACTOR SHALL ADHERE TO METHODS AS DESCRIBED IN THE PROJECT SWPPP. 10.COMPLETED WORK THAT IS NOT SUBJECT TO FURTHER EARTHWORK OR CONSTRUCTION ACTIVITIES SHALL BE PERMANENTLY HYDRO SEEDED IN EARLY SPRING OF FALL. GRADING NOTES 1.ALL SURVEY AND SITE STAKEOUTS FOR PROPOSED FEATURES SHALL BE PERFORMED BY A NEW YORK STATE LICENSED SURVEYOR. 2.CONTRACTOR WILL BE RESPONSIBLE TO LOCATE, MARK AND PROTECT ALL EXISTING SURVEY, PROPERTY, AND RIGHT-OF-WAY MARKERS FOR THE SITE. ANY MARKERS, PINS, MONUMENTS OR OTHER FEATURES DEFINING PROPERTY LIMITS THAT MAY BE DISTURBED BY CONSTRUCTION ACTIVITIES SHALL BE PROPERLY TIED AND RESET BY A NEW YORK STATE LICENSED SURVEYOR UPON COMPLETION OF THE WORK. 3.THE HORIZONTAL DATUM IS NAD83 NEW YORK STATE PLANE COORDINATE SYSTEM, (US FT). 4.THE VERTICAL DATUM IS NAVD88. 1.GRADING DESIGN SHOWN IN THESE PLANS IS BASED ON NYS LIDAR INFORMATION PROVIDED TO PWGC BY THEW ASSOCIATES AND IS TO BE CONSIDERED APPROXIMATE. GRADING DESIGN IS SUBJECT TO CHANGE BASED ON FURTHER SITE INVESTIGATIONS AND ANALYSIS. 2.ADDITIONAL SITE GEOTECHNICAL ANALYSIS IS REQUIRED TO VERIFY GRADING CONSTRAINTS AND FEASIBILITY. 3.GRADING SHALL PERFORMED IN ACCORDANCE WITH ALL APPLICABLE STATE AND OSHA REQUIREMENTS. THE CONTRACTOR SHALL CONFORM TO THE REQUIREMENTS OF OSHA, AND ANY OTHER AGENCY HAVING JURISDICTION WITH REGARD TO SAFETY PRECAUTIONS WITH TRENCHING OR EXCAVATION AND GRADING OPERATIONS. THE REQUIREMENTS SET FORTH HEREIN ARE INTENDED TO SUPPLEMENT REQUIREMENTS ESTABLISHED BY THESE AGENCIES. IN THE CASE OF A CONFLICT BETWEEN REQUIREMENTS OF OTHER JURISDICTIONAL AGENCIES AND THESE DOCUMENTS, THE MORE STRINGENT REQUIREMENT ON THE CONTRACTOR SHALL APPLY. 4.VOIDS LEFT BY UTILITY OR STRUCTURE EXCAVATIONS, OR GRUBBING OPERATIONS SHALL BE BACKFILLED AND PROPERLY COMPACTED WITH STRUCTURAL FILL (NYSDOT ITEM 304.12 OR EQUIVALENT) IN AREAS UNDER AND WITHIN 5 FEET HORIZONTALLY OF ALL STRUCTURES, AND PAVEMENTS. IN GRASSED AREAS, VOIDS LEFT SHALL BE FILLED AND PROPERLY COMPACTED WITH SUITABLE ON-SITE BACKFILL AS APPROVED BY THE ENGINEER. 5.THE CONTRACTOR SHALL DEWATER ALL EXCAVATIONS TO PREVENT THE INTRODUCTION OF GROUNDWATER OR PONDED WATER INTO THE TRENCHES/EXCAVATIONS AND WILL PROVIDE ALL EQUIPMENT NECESSARY TO MAINTAIN THE WATER AS NECESSARY. DEWATERING SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SWPPP. 6.UNLESS OTHERWISE DIRECTED, THE CONTRACTOR SHALL PLACE AT MINIMUM 6 INCHES OF CLEAN TOPSOIL IN ALL DISTURBED AND NEWLY GRADED AREAS PRIOR TO SEEDING. TM # :31.-1-12.1 EXISTING ZONING:RURAL AGRICULTURAL LOT AREA: 58.73 ACRES PROPOSED USE:LARGE SCALE SOLAR REQUIRED PROPOSED LOT SIZE 5 AC.58.73 AC. MAX. LOT COVERAGE 75%10.05% MAX. HEIGHT 20' 15' PROPERTY SETBACK (FRONT ℄ ROAD)150'835' PROPERTY SETBACK (SIDE/BACK)75'75' ZONING ANALYSIS Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 0 0 1 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 1 8 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 D R A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 SOLAR MODULE NOTES MANUFACTURER:HELIENE MODEL:Q.PEAK DUO XL-G11.3 / BFG MODULE OUTPUT POWER:585 WP STRING SIZE:24 NUMBER OF STRINGS:310 MODULE QUANTITY:7,440 PV SYSTEM OUTPUT 4,352.40 KWP DC NOTES: 1.SOLAR PANELS TO BE INSTALLED BY A QUALIFIED SOLAR INSTALLER AND SHALL BE BUILT, OPERATED AND MAINTAINED TO ACCEPTABLE INDUSTRY STANDARDS INCLUDING BUT NOT LIMITED TO THE MOST RECENT, APPLICABLE STANDARDS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS ("IEEE") AND THE AMERICAN NATIONAL STANDARDS INSTITUTE. EARTHWORK CALCULATIONS TOTAL CUT: 21,000 CY TOTAL FILL: 28,000 CY NET CUT/FILL: 7,000 CY NOTE: 1.NO SHRINK/SWELL MULTIPLIER WAS APPLIED TO THE TOTAL CUT AND FILL VALUES. 2.CUT/FILL NUMBERS ARE AN ESTIMATED VALUE. CONTRACTOR IS RESPONSIBLE FOR THEIR OWN CUT/FILL QUANTITIES. RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED GENERAL NOTES AND LEGEND INFORMATION C-001 02 EROSION AND SEDIMENT CONTROL TOPOGRAPHIC FEATURES MINOR CONTOURS (2-FT INTERVAL) MAJOR CONTOURS (10-FT INTERVAL) DRAINAGE ELEMENTS SITE FEATURES OVERHEAD ELECTRICAL UTILITY APPROXIMATE WETLAND AREA ADJACENT PROPERTY BOUNDARY PAVED ROADWAY GRAVEL ROADWAY UNDERGROUND ELECTRICAL UTILITY 8-FT TALL DEER FENCE SOLAR PANEL ARRAY SEED RESTORATION LIMITS GRASSED WATERWAY LAND GRADING ACTIVITIES STABILIZED CONSTRUCTION ENTRANCE DUST CONTROL MEASURESDC AREA OF DISTURBANCE PROPERTY BOUNDARY LEGEND ZONING SETBACK EXISTING PROPOSED NOTES CULVERT STOCKPILE CONCRETE WASHOUT 1320 TREE LINE TREE CUTTING LIMITS (NO GRUBBING OR GROUND DISTURBANCE SITE COVERAGE CALCULATION SOLAR PANELS: (8 FT x 3.7 FT) x 7,440 PANELS = 5.06 AC ACCESS ROAD 0.84 AC INVERTER/TRANSFORMER PADS 0.001 AC TOTAL: 5.90 AC SITE COVERAGE: 5.90 AC / 58.73 AC = 10.05% GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 JOSEPH C MILLER TM#: 31.-1-12.212 JAMES R YOUNG TM#: 26.-1-25.22 JOSEPH C MILLER TM#: 31.-1-12.211 GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.4 SAMUEL P SWEENEY III 31.-1-19.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.6 SAMUEL P SWEENEY III 31.-1-19.51 JOHN YOUNG TM#: 31.-1-12.1 F&M LAND LLC TM#: 26.-1-24.1 S O U T H M A I N S T R E E T E X T . FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 ROBERT J COSTA TM#: 31.-1-9 DARCY L WYLLIE TM#: 31.-1-20 JOSEPH C MILLER TM#: 31.-1-12.22 APPROXIMATE LIMITS OF DISTURBANCE, ±21.44 AC. APPROXIMATE LIMITS OF TREE CUTTING ONLY. NO GRUBBING, ±7.06 AC. PROPERTY LINE (± 58.73 AC) EXISTING OVERHEAD ELECTRIC EXISTING STREAM (OWASCO INLET) EXISTING FARMLAND EXISTING TREE LINE POTENTIAL WETLANDS EXISTING NATIONAL WETLANDS EXISTING TREE LINE TO REMAIN POTENTIAL WETLANDS EXISTING STREAM (OWASCO INLET) 10 7 0 10 8 0 109 0 1100 1110 1120 1 0 7 0 1 0 8 0 1 0 9 0 11 0 0 1 1 1 0 1120 1 1 3 0 1030 1040 10 5 0 10 6 0 1 0 7 0 1 0 8 0 1 0 9 0 110 0 1110 1 1 2 0 1060 1070 10 2 0 1 0 3 0 1 0 4 0 105 0 1 0 6 0 1 0 7 0 1 0 8 0 1 0 9 0 Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 1 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 1 8 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 SCALE: 1" = 100' 0 100 200 RPV/NRD RPV/NRD 11/15/23 MTS/EJK 1" = 100' EXISTING CONDITIONS PLAN C-100 03 EROSION AND SEDIMENT CONTROL TOPOGRAPHIC FEATURES MINOR CONTOURS (2-FT INTERVAL) MAJOR CONTOURS (10-FT INTERVAL) DRAINAGE ELEMENTS SITE FEATURES OVERHEAD ELECTRICAL UTILITY APPROXIMATE WETLAND AREA ADJACENT PROPERTY BOUNDARY PAVED ROADWAY GRAVEL ROADWAY UNDERGROUND ELECTRICAL UTILITY 8-FT TALL DEER FENCE SOLAR PANEL ARRAY SEED RESTORATION LIMITS GRASSED WATERWAY LAND GRADING ACTIVITIES STABILIZED CONSTRUCTION ENTRANCE DUST CONTROL MEASURESDC AREA OF DISTURBANCE PROPERTY BOUNDARY LEGEND ZONING SETBACK EXISTING PROPOSED NOTES CULVERT STOCKPILE CONCRETE WASHOUT 1320 TREE LINE TREE CUTTING LIMITS (NO GRUBBING OR GROUND DISTURBANCE GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 JOSEPH C MILLER TM#: 31.-1-12.212 JAMES R YOUNG TM#: 26.-1-25.22 JOSEPH C MILLER TM#: 31.-1-12.211 GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.4 SAMUEL P SWEENEY III 31.-1-19.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.6 SAMUEL P SWEENEY III 31.-1-19.51 JOHN YOUNG TM#: 31.-1-12.1 F&M LAND LLC TM#: 26.-1-24.1 S O U T H M A I N S T R E E T E X T . FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 ROBERT J COSTA TM#: 31.-1-9 DARCY L WYLLIE TM#: 31.-1-20 JOSEPH C MILLER TM#: 31.-1-12.22 50' SETBACK 75.0' 75.0' 75.0' 150.0' INVERTER PAD, SEE DETAIL SHEET C-900 CUSTOMER TRANSFORMER 2.5 MVA, SEE DETAIL SHEET C-900 PANEL MANUFACTURER: HELIENE NUMBER OF MODULES: 7,440 MODULE MODEL 156HC ML10 SL BIFACIAL575WP INVERTER MANUFACTURER: CPS MODEL: SCH250K-T-US-600 NUMBER OF INVERTERS: 15 SIZE OF EACH INVERTER: 2500 KVA CONNECTION CABLE SECTION: 3 - 1/C # 2/0 AWG WITH 100% CONCENTRIC NEUTRAL 35 KV UNDERGROUND LENGTH: 1,334.03 FT/PHASE CABLE 34.5 KV 3PH OVERHEAD: COMPANY NYSEG SUBSTATION PERUVILLE TAP NUMBER OF PHASES 3 CIRCUIT NAME 4303701 NEW UTILITY POLE AAAC/ACSR 4 -1 1/C #250 KCMIL OVERHEAD LENGTH 310.30 FT/PHASE CABLE PRESUMED POI LOCATION PROPOSED 8' TALL DEER FENCE (± 3,887 LF), TYP. SEE DETAIL SHEET C-900 PROPOSED CRUSHED STONE ACCESS ROAD SEE DETAIL SHEET C-900 ZONING SETBACK, TYP. NOTE: IT IS NECESSARY TO REQUEST THE UTILITY TO UPGRADE EXISTING 1PH LINE TO 3PH LINE AND EXTEND THE LINE TO THE NEW POI. APPROXIMATE LOCATION OF STAGING AREA PROPOSED CYPRESS LEYLAND VISUAL SCREENING, TYP. 21 PROPOSED PRECAST OPEN-BOTTOM CULVERT LIMIT OF SITE DISTURBANCE (± 21.58 AC) LIMIT OF TREE CUTTING ONLY. NO GRUBBING. (± 7.22 AC) 50 STREAM SETBACK FENCED AREA: 16.17 AC CUSTOMER TRANSFORMER 1.5 MVA, SEE DETAIL SHEET C-900 807.2' CONNECTION CABLE SHALL BE RUN ABOVE GRADE AT STREAM CROSSING TREE CLEARING WITHIN FENCE 2.63 AC. UTILITY RECLOSER POLE UTILITY METER POLE PROJECT GOAB PROJECT RECLOSER PROJECT METER/RISER Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 2 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 1 9 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 SYSTEM SUMMARY FENCED AREA 8' TALL DEER FENCE 16.17 AC MODULE: MANUFACTURER: HELIENE MODEL: 156HC ML10 SL BIFACIAL MODULE OUTPUT POWER: 575 WP STRING SIZE: 24 NUMBER OF STRINGS: 310 MODULE QUANTITY: 7,440 PV SYSTEM OUTPUT: 4,914.00 KWP DC COMBINER BOX: CB QTY/INPUTS (QTY/INP): 25 CBs (6 INPUTS) 5 CBs (5 INPUTS) INVERTER: MANUFACTURER: CPS MODEL: SCH250K-T-US-600 QUANTITY/RATING: 15 / 250 KVA PV SYSTEM OUTPUT: 3,750 KVA AC DC SYSTEM VOLTAGE: 900 V MV INTERCONNECTION: TRANSFORMER QTY/RATING: 1 / 4,400 KVA INTERCON. VOLTAGE: 34.5 KV RACKING: MANUFACTURER: NEVADOS CONFIGURATION: 2 MODULE POTRAIT TILT: 25° AZIMUTH: 180° CUT/FILL CUT :21,000 CY FILL :28,00 CY SCALE: 1" = 100' 0 100 200 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED SITE LAYOUT PLAN C-200 04 EROSION AND SEDIMENT CONTROL TOPOGRAPHIC FEATURES MINOR CONTOURS (2-FT INTERVAL) MAJOR CONTOURS (10-FT INTERVAL) DRAINAGE ELEMENTS SITE FEATURES OVERHEAD ELECTRICAL UTILITY APPROXIMATE WETLAND AREA ADJACENT PROPERTY BOUNDARY PAVED ROADWAY GRAVEL ROADWAY UNDERGROUND ELECTRICAL UTILITY 8-FT TALL DEER FENCE SOLAR PANEL ARRAY SEED RESTORATION LIMITS GRASSED WATERWAY LAND GRADING ACTIVITIES STABILIZED CONSTRUCTION ENTRANCE DUST CONTROL MEASURES AREA OF DISTURBANCE PROPERTY BOUNDARY LEGEND ZONING SETBACK EXISTING PROPOSED NOTES CULVERT STOCKPILE CONCRETE WASHOUT 1320 TREE LINE TREE CUTTING LIMITS (NO GRUBBING OR GROUND DISTURBANCE GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 JOSEPH C MILLER TM#: 31.-1-12.212 JAMES R YOUNG TM#: 26.-1-25.22 JOSEPH C MILLER TM#: 31.-1-12.211 GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.4 SAMUEL P SWEENEY III 31.-1-19.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.6 SAMUEL P SWEENEY III 31.-1-19.51 JOHN YOUNG TM#: 31.-1-12.1 F&M LAND LLC TM#: 26.-1-24.1 S O U T H M A I N S T R E E T E X T . FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 ROBERT J COSTA TM#: 31.-1-9 DARCY L WYLLIE TM#: 31.-1-20 JOSEPH C MILLER TM#: 31.-1-12.22 10 7 0 10 8 0 109 0 1100 1110 1120 1 0 7 0 1 0 8 0 1 0 9 0 11 0 0 1 1 1 0 1120 1 1 3 0 1030 1040 10 5 0 10 6 0 1 0 7 0 1 0 8 0 1 0 9 0 110 0 1110 1 1 2 0 1060 1070 10 2 0 1 0 3 0 1 0 4 0 105 0 1 0 6 0 1 0 7 0 1 0 8 0 1 0 9 0 PROPOSED GRADING PROPOSED CULVERT, SEE DETAIL SHEET C-902 PROPOSED WATER BARS (TYP.) 1 0 7 0 1 0 8 0 PROPOSED WATER BAR (TYP.) ACROSS TOP OF SITE. PROPOSED FILTER STRIPS, SEE DETAIL SHEET C-902 1062 1060 106 2 106 4 106 6 106 8 1070 10 7 2 Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 3 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 1 9 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 NOTE: THE PROPOSED GRADING SHOWN HAS A MAX CUT OF 14.6' BGS. BEDROCK HAS BEEN ENCOUNTERED IN ONE TEST PIT PERFORMED WITHIN THE PROJECT AREA. ALL TEST PITS WERE COMPLETED 10' BGS. NO CUT HAS BEEN PROPOSED IN LOCATIONS WITH SHALLOW BEDROCK. SCALE: 1" = 100' 0 100 200 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED GRADING AND DRAINAGE PLAN C-300 05 EROSION AND SEDIMENT CONTROL TOPOGRAPHIC FEATURES MINOR CONTOURS (2-FT INTERVAL) MAJOR CONTOURS (10-FT INTERVAL) DRAINAGE ELEMENTS SITE FEATURES OVERHEAD ELECTRICAL UTILITY APPROXIMATE WETLAND AREA ADJACENT PROPERTY BOUNDARY PAVED ROADWAY GRAVEL ROADWAY UNDERGROUND ELECTRICAL UTILITY 8-FT TALL DEER FENCE SOLAR PANEL ARRAY SEED RESTORATION LIMITS GRASSED WATERWAY LAND GRADING ACTIVITIES STABILIZED CONSTRUCTION ENTRANCE DUST CONTROL MEASURESDC AREA OF DISTURBANCE PROPERTY BOUNDARY LEGEND ZONING SETBACK EXISTING PROPOSED NOTES CULVERT STOCKPILE CONCRETE WASHOUT 1320 TREE LINE TREE CUTTING LIMITS (NO GRUBBING OR GROUND DISTURBANCE 0+ 0 0 1+002+003+00 4+0 0 20 ' 20' R2 2 8 ' R2 4 8 ' R8 4 ' R9 7 ' EL E V A T I O N EL E V A T I O N STATION 1100 1110 1120 1130 1140 1150 1160 1170 1100 1110 1120 1130 1140 1150 1160 1170 -0+250+001+002+003+004+00 EX: -9.68%EXISTING GRADE Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 4 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 1 9 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 D R A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED ACCESS ROAD PLAN & PROFILE STA 0+00 - 4+00 C-400 06 ACCESS ROAD PROFILE STA 0+00 TO STA 4+00 VERTICAL SCALE: 1" = 2' HORIZONTAL SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' ACCESS ROAD PLAN STA 0+00 TO STA 4+00 SCALE: 1" = 20' 0 2 4 SCALE 1" = 2' UTILITY RECLOSER POLE NEW UTILITY POLE AAAC/ACSR 4 -1 1/C #250 KCMIL OVERHEAD LENGTH 310.30 FT/PHASE CABLE UTILITY METER POLEPROJECT GOABPROJECT RECLOSERPROJECT METER/RISER 3+ 0 0 4+0 0 5+00 6+007+00 8+00 10 8 4 10 8 6 20' R 7 7 ' R 9 7 ' R1 4 1 1 ' R1 4 5 8 ' 20' 20' EL E V A T I O N EL E V A T I O N STATION 1030 1040 1050 1060 1070 1080 1090 1100 1110 1120 1130 1140 1150 1160 1170 1030 1040 1050 1060 1070 1080 1090 1100 1110 1120 1130 1140 1150 1160 1170 4+005+006+007+008+00 EX: -4.49% EXISTING GRADE Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 4 0 1 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 1 9 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 D R A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED ACCESS ROAD PLAN & PROFILE STA 4+00 - 8+00 C-401 07 ACCESS ROAD PROFILE STA 4+00 TO STA 8+00 VERTICAL SCALE: 1" = 2' HORIZONTAL SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' ACCESS ROAD PLAN STA 4+00 TO STA 8+00 SCALE: 1" = 20' 0 2 4 SCALE 1" = 2' 8+00 9+00 10+0011+00 12 + 0 0 10 7 4 1 0 7 6 1 0 7 8 1 0 8 0 1 0 8 2 1 0 8 4 1 0 8 6 1060 1062 1064 1066 1068 1070 1072 1070 1072 106 410 6 6 10 6 8 10 7 0 10 7 2 10 7 4 1066 1068 1070 1072 1074 1 0 6 2 1 0 6 4 1 0 6 6 STA:11+24.98 20' R 7 2 ' R 9 2 ' 20'20' 20' R40 ' R 4 0 ' 1062 EL E V A T I O N EL E V A T I O N STATION 1030 1040 1050 1060 1070 1080 1090 1100 1030 1040 1050 1060 1070 1080 1090 1100 8+009+0010+0011+0011+25 -1.11% EX: -8.39% PROPOSED GRADE EXISTING GRADE Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 4 0 2 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 0 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 D R A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED ACCESS ROAD PLAN & PROFILE STA 8+00 - 11+24.98 C-402 08 ACCESS ROAD PROFILE STA 8+00 TO STA 11+24.98 VERTICAL SCALE: 1" = 2' HORIZONTAL SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' ACCESS ROAD PLAN STA 8+00 TO STA 11+24.98 SCALE: 1" = 20' 3-SIDED OPEN BOX CULVERT MINIMUM WIDTH OF CULVERT SHALL BE 1.5 TIMES STREAM WIDTH 0 2 4 SCALE 1" = 2' 11 + 0 0 12+00 13+00 14+00 10 7 4 107 2 1074 1 0 6 0 1 0 6 2 10 6 4 10 6 6 10 6 8 10 7 0 10 7 2 10 7 0 10 7 2 1 0 6 4 106 6 106 8 107 0 10 7 2 10 7 4 10 6 6 1058 1060 1062 1064 1066 1068 1070 1072 1074 1062 1064 1066 1068 1070 1072 STA:11+24.98 R4 0 ' R 4 0 ' 20' 20' 20 ' 20 ' 1 0 6 2 1 0 6 2 1 0 6 4 1 0 6 6 1 0 6 8 1 0 7 0 1072 EL E V A T I O N EL E V A T I O N STATION 1030 1040 1050 1060 1070 1080 1090 1100 1030 1040 1050 1060 1070 1080 1090 1100 11+25 12+00 13+00 14+00 14+50 EX: -1.40% -1.33% PROPOSED GRADE EXISTING GRADE3-SIDED OPEN BOX CULVERT MINIMUM WIDTH OF CULVERT SHALL BE 1.5 TIMES WIDTH OF STREAMPRECAST STEM WALL FOOTINGS Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 4 0 3 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 0 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 D R A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED ACCESS ROAD PLAN & PROFILE STA 11+24.98 - 14+50 C-403 09 ACCESS ROAD PROFILE STA 11+24.98 TO STA 14+50 VERTICAL SCALE: 1" = 2' HORIZONTAL SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' ACCESS ROAD PLAN STA 11+24.98 TO STA 14+50 SCALE: 1" = 20' 3-SIDED OPEN BOX CULVERT MINIMUM WIDTH OF CULVERT SHALL BE 1.5 TIMES STREAM WIDTH CULVERT NOTES 1.CONTRACTOR SHALL VERIFY STREAM WIDTH IN FIELD. 2.CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF CULVERT WITH MINIMAL DISTURBANCE TO STREAM BOTTOM. 3.CONTRACTOR SHALL INSTALL CULVERT AND FOOTINGS IN ACCORDANCE WITH MANUFACTURES REQUIREMENTS. 4.CULVERT SHALL BE A MINIMUM WIDTH OF 1.5 TIMES THE WIDTH OF THE STREAM BANKS. 5.CONTRACTOR SHALL SUBMIT SHOP DRAWING OF CULVERT AND FOOTINGS BEFORE ORDERING AND INSTALLING TO ENGINEER. 0 2 4 SCALE 1" = 2' 14+00 15+00 16+00 17+00 17+03 1070107 2 20 ' 1066 1068 1068 1 0 6 2 1 0 6 4 1 0 6 6 1 0 6 8 1 0 7 0 1072 EL E V A T I O N EL E V A T I O N STATION 1030 1040 1050 1060 1070 1080 1090 1100 1030 1040 1050 1060 1070 1080 1090 1100 14+50 15+00 16+00 17+00 17+25 EX: -3.60% -1.13% PROPOSED GRADE EXISTING GRADE Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 4 0 4 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 0 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 D R A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED ACCESS ROAD PLAN & PROFILE STA 14+50 - 17+03 C-404 10 ACCESS ROAD PROFILE STA 14+50 TO STA 17+03 VERTICAL SCALE: 1" = 2' HORIZONTAL SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' 0 20 40 SCALE: 1" = 20' ACCESS ROAD PLAN STA 14+50 TO STA 17+03 SCALE: 1" = 20' 0 2 4 SCALE 1" = 2' GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 JOSEPH C MILLER TM#: 31.-1-12.212 JAMES R YOUNG TM#: 26.-1-25.22 JOSEPH C MILLER TM#: 31.-1-12.211 GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.4 SAMUEL P SWEENEY III 31.-1-19.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.6 SAMUEL P SWEENEY III 31.-1-19.51 JOHN YOUNG TM#: 31.-1-12.1 F&M LAND LLC TM#: 26.-1-24.1 S O U T H M A I N S T R E E T E X T . DC FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 ROBERT J COSTA TM#: 31.-1-9 DARCY L WYLLIE TM#: 31.-1-20 JOSEPH C MILLER TM#: 31.-1-12.22 IMPLEMENT DUST CONTROL AS NECESSARY LAND GRADING ACTIVITIES, TYP. APPROXIMATE LOCATION OF STOCKPILES, TYP. SEE DETAIL SHEET C-901 PROPOSED STABILIZED CONSTRUCTION ENTRANCE, SEE DETAIL SHEET C-901 PROPOSED SILT SOCK SEE DETAIL SHEET C-901 UNDISTURBED RIPARIAN BUFFER (NATIVE VEGETATION) MIN 40' SETBACK FROM WATERCOURSE LINEAR STOCKPILES NEXT TO ACCESS ROAD AND ELECTRICAL TRENCH, TYP. Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 5 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 1 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 D R A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 SCALE: 1" = 100' 0 100 200 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED EROSION AND SEDIMENT CONTROL PLAN C-500 11 EROSION AND SEDIMENT CONTROL TOPOGRAPHIC FEATURES MINOR CONTOURS (2-FT INTERVAL) MAJOR CONTOURS (10-FT INTERVAL) DRAINAGE ELEMENTS SITE FEATURES OVERHEAD ELECTRICAL UTILITY APPROXIMATE WETLAND AREA ADJACENT PROPERTY BOUNDARY PAVED ROADWAY GRAVEL ROADWAY UNDERGROUND ELECTRICAL UTILITY 8-FT TALL DEER FENCE SOLAR PANEL ARRAY SEED RESTORATION LIMITS GRASSED WATERWAY LAND GRADING ACTIVITIES STABILIZED CONSTRUCTION ENTRANCE DUST CONTROL MEASURESDC AREA OF DISTURBANCE PROPERTY BOUNDARY LEGEND ZONING SETBACK EXISTING PROPOSED NOTES CULVERT STOCKPILE CONCRETE WASHOUT 1320 TREE LINE TREE CUTTING LIMITS (NO GRUBBING OR GROUND DISTURBANCE JOSEPH C MILLER TM#: 31.-1-12.212 JAMES R YOUNG TM#: 26.-1-25.22 JOSEPH C MILLER TM#: 31.-1-12.211 SAMUEL P SWEENEY III 31.-1-19.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.6 SAMUEL P SWEENEY III 31.-1-19.51 JOHN YOUNG TM#: 31.-1-12.1 F&M LAND LLC TM#: 26.-1-24.1 S O U T H M A I N S T R E E T E X T . JOSEPH C MILLER TM#: 31.-1-12.22 Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 6 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 1 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 PHASE SCHEDULE 1 (4.12± ACRE) 1.PRE-CONSTRUCTION MEETING 2.INSTALL PERIMETER SILT FENCE AND OTHER E&S CONTROL MEASURES AS SHOWN. 3. HAVE A QUALIFIED PROFESSIONAL CONDUCT A SITE ASSESSMENT PRIOR TO THE START OF CONSTRUCTION. 4.INSTALL TEMPORARY CONSTRUCTION ENTRANCE AND ROAD AS SHOWN. 5.INSTALL STAGING AREA & PARKING AREA. 6.COMMENCE CLEARING, TRIMMING, & GRUBBING OPERATIONS. 7.STABILIZE ALL DISTURBED AREAS IDLE IN EXCESS OF 7 DAYS IN WHICH CONSTRUCTION WILL NOT RESUME WITHIN 14 DAYS. 8.INSTALL PERIMETER FENCE & GATE AND ELECTRICAL UTILITIES. 9.STABILIZE AND HYDROSEED ALL DISTURBED AREAS. 10.REMOVE TEMPORARY CONSTRUCTION ROAD AND INSTALL THE PROPOSED LIMITED USE PERVIOUS GRAVEL DRIVEWAY ONCE ALL PHASES HAVE BEEN COMPLETED. 2 (4.79± ACRE) 3 (2.73± ACRE) 1.PRE-CONSTRUCTION MEETING 2.INSTALL PERIMETER SILT FENCE AND OTHER E&S CONTROL MEASURES AS SHOWN. 3.HAVE A QUALIFIED PROFESSIONAL CONDUCT A SITE ASSESSMENT PRIOR TO THE START OF CONSTRUCTION. 4.COMMENCE CLEARING, TRIMMING, & GRUBBING OPERATIONS. 5.STABILIZE ALL DISTURBED AREAS IDLE IN EXCESS OF 7 DAYS IN WHICH CONSTRUCTION WILL NOT RESUME WITHIN 14 DAYS. 6.INSTALL PERIMETER FENCE, ELECTRICAL UTILITIES, WATER BARS, AND SOLAR PANELS PROGRESSING FROM THE SOUTH TO THE NORTH. 7.STABILIZE AND HYDROSEED ALL DISTURBED AREAS. 8.CONTRACTOR SHALL NOT PROCEED TO THE NEXT PHASE UNTIL THE SOLAR PANELS HAVE BEEN INSTALLED AND TEMPORARY STABILIZATION HAS BEEN ACHIEVED WITH SEED AND MULCH. 4 (4.85± ACRE) 5 (4.89± ACRE) NOTES: 1. SURVEYORS WILL BE INSTRUCTED TO STAKE OUT THE BOUNDARIES FOR EACH PHASE OF CONSTRUCTION. 2. CONTRACTOR SHALL NOT EXCEED 5 ACRES OF DISTURBANCE AT ANY ONE GIVEN TIME FOR EACH PHASE OF CONSTRUCTION UNLESS RECEIVED APPROVAL FOR 5 ACRE WAIVER. 3. PLEASE NOTE THAT THE ACREAGE FOR EACH PHASE DOES NOT REPRESENT THE ACREAGE OF PHYSICAL GROUND DISTURBANCE. THE BOUNDARY FOR EACH PHASE IS ONLY A REPRESENTATION OF THE AREA IN WHICH THE CONTRACTOR MAY OPERATE. 4. EACH PHASE MUST BE STABILIZED IN ACCORDANCE WITH NYSDEC STANDARDS AND SPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL (BLUEBOOK) BEFORE DISTURBANCE CAN BEGIN ON THE NEXT PHASE. 1.PRE-CONSTRUCTION MEETING 2.INSTALL PERIMETER SILT FENCE AND OTHER E&S CONTROL MEASURES AS SHOWN. 3.HAVE A QUALIFIED PROFESSIONAL CONDUCT A SITE ASSESSMENT PRIOR TO THE START OF CONSTRUCTION. 4.INSTALL TEMPORARY OFFICE TRAILER, STAGING AREA, STORAGE CONTAINER, CONCRETE WASHOUT AREA, & PARKING AREA. 5.COMMENCE CLEARING, TRIMMING, & GRUBBING OPERATIONS. 6.STABILIZE ALL DISTURBED AREAS IDLE IN EXCESS OF 7 DAYS IN WHICH CONSTRUCTION WILL NOT RESUME WITHIN 14 DAYS. 7.INSTALL PERIMETER FENCE & GATE, ELECTRICAL UTILITIES, EQUIPMENT PAD, AND THE WATER BARS. 8.STABILIZE AND HYDROSEED ALL DISTURBED AREAS. 9.SOLAR PANELS SOUTH OF THE ROAD SHOULD NOT BE INSTALLED UNTIL AFTER LAND MASS GRADING AND WILL BE USED FOR TEMPORARY LAND MASS GRADING STOCKPILES. 10.CONTRACTOR SHALL AIM TO INSTALL RAIN GARDEN IN PHASE 3 BEFORE CONTINUING TO MOVE CUT MATERIAL TO PHASES 4 AND 5. PATH MAY BE REQUIRED FROM PHASE 7 TO MOVE CUT TO PHASE 6. 11.REMOVE TEMPORARY CONSTRUCTION ROAD AND INSTALL THE PROPOSED LIMITED USE PERVIOUS GRAVEL DRIVEWAY ONCE ALL PHASES HAVE BEEN COMPLETED. 1.PRE-CONSTRUCTION MEETING 2.INSTALL PERIMETER SILT FENCE AND OTHER E&S CONTROL MEASURES AS SHOWN. 3.HAVE A QUALIFIED PROFESSIONAL CONDUCT A SITE ASSESSMENT PRIOR TO THE START OF CONSTRUCTION. 4.COMMENCE CLEARING, TRIMMING, & GRUBBING OPERATIONS. 5.STABILIZE ALL DISTURBED AREAS IDLE IN EXCESS OF 7 DAYS IN WHICH CONSTRUCTION WILL NOT RESUME WITHIN 14 DAYS. 6.INSTALL PERIMETER FENCE, ELECTRICAL UTILITIES, WATER BARS, AND SOLAR PANELS PROGRESSING FROM THE SOUTH TO NORTH. 7.STABILIZE AND HYDROSEED ALL DISTURBED AREAS. 8.CONTRACTOR SHALL NOT PROCEED TO THE NEXT PHASE UNTIL THE SOLAR PANELS HAVE BEEN INSTALLED AND TEMPORARY STABILIZATION HAS BEEN ACHIEVED WITH SEED AND MULCH. 1.PRE-CONSTRUCTION MEETING 2.INSTALL PERIMETER SILT FENCE AND OTHER E&S CONTROL MEASURES AS SHOWN. 3.HAVE A QUALIFIED PROFESSIONAL CONDUCT A SITE ASSESSMENT PRIOR TO THE START OF CONSTRUCTION. 4.COMMENCE CLEARING, TRIMMING, & GRUBBING OPERATIONS. 5.STABILIZE ALL DISTURBED AREAS IDLE IN EXCESS OF 7 DAYS IN WHICH CONSTRUCTION WILL NOT RESUME WITHIN 14 DAYS. 6.INSTALL PERIMETER FENCE, ELECTRICAL UTILITIES, WATER BARS, AND SOLAR PANELS PROGRESSING FROM THE SOUTH TO NORTH. 7.STABILIZE AND HYDROSEED ALL DISTURBED AREAS. 8.CONTRACTOR SHALL NOT PROCEED TO THE NEXT PHASE UNTIL THE SOLAR PANELS HAVE BEEN INSTALLED AND TEMPORARY STABILIZATION HAS BEEN ACHIEVED WITH SEED AND MULCH. SCALE: 1" = 100' 0 100 200 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED PHASING PLAN C-600 12 1 2 34 5 GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 JOSEPH C MILLER TM#: 31.-1-12.212 JAMES R YOUNG TM#: 26.-1-25.22 JOSEPH C MILLER TM#: 31.-1-12.211 GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.4 SAMUEL P SWEENEY III 31.-1-19.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.6 SAMUEL P SWEENEY III 31.-1-19.51 JOHN YOUNG TM#: 31.-1-12.1 F&M LAND LLC TM#: 26.-1-24.1 S O U T H M A I N S T R E E T E X T . FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 ROBERT J COSTA TM#: 31.-1-9 DARCY L WYLLIE TM#: 31.-1-20 JOSEPH C MILLER TM#: 31.-1-12.22 PROPOSED VEGETATION VISUAL SCREENING TYP. 21, SEE PLANTING DETAIL SHEET C-901 PROPOSED SEEDING AREA, ±20.66 AC. 3' SOLAR POLLINATOR MIX, SEE SEEDING SPECIFICATION SHEET C-901 Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 7 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 1 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 SCALE: 1" = 100' 0 100 200 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED LANDSCAPING PLAN C-700 13 EROSION AND SEDIMENT CONTROL TOPOGRAPHIC FEATURES MINOR CONTOURS (2-FT INTERVAL) MAJOR CONTOURS (10-FT INTERVAL) DRAINAGE ELEMENTS SITE FEATURES OVERHEAD ELECTRICAL UTILITY APPROXIMATE WETLAND AREA ADJACENT PROPERTY BOUNDARY PAVED ROADWAY GRAVEL ROADWAY UNDERGROUND ELECTRICAL UTILITY 8-FT TALL DEER FENCE SOLAR PANEL ARRAY SEED RESTORATION LIMITS GRASSED WATERWAY LAND GRADING ACTIVITIES STABILIZED CONSTRUCTION ENTRANCE DUST CONTROL MEASURESDC AREA OF DISTURBANCE PROPERTY BOUNDARY LEGEND ZONING SETBACK EXISTING PROPOSED NOTES CULVERT STOCKPILE CONCRETE WASHOUT 1320 TREE LINE TREE CUTTING LIMITS (NO GRUBBING OR GROUND DISTURBANCE GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 JOSEPH C MILLER TM#: 31.-1-12.212 JAMES R YOUNG TM#: 26.-1-25.22 JOSEPH C MILLER TM#: 31.-1-12.211 GENEVIEVE VANBENSCHOTEN TM#: 31.-1-13.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.4 SAMUEL P SWEENEY III 31.-1-19.2 DOUGLAS VANBENSCHOTEN TM#: 31.-1-19.6 SAMUEL P SWEENEY III 31.-1-19.51 JOHN YOUNG TM#: 31.-1-12.1 F&M LAND LLC TM#: 26.-1-24.1 S O U T H M A I N S T R E E T E X T . FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 FREDRIC JAY PORTZLINE TM#: 31.-1-7.1 ROBERT J COSTA TM#: 31.-1-9 DARCY L WYLLIE TM#: 31.-1-20 JOSEPH C MILLER TM#: 31.-1-12.22 Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 8 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 1 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 SOIL GROUPS TABLE SOIL GROUP NUMBER TOTAL AREA ON SITE AREA DISTURBED SOIL TYPE 1 0 AC.0 AC. SOIL TYPE 2 10.36± AC.3.78± AC. SOIL TYPE 3 1.87± AC.0.9± AC. SOIL TYPE 4 0 AC.0 AC. FARMLAND DISTURBANCE TABLE FARMLAND CLASSIFICATION EARTHWORK DISTURBANCE AREA PERMANENT DISTURBANCE AREA PROJECT FOOTPRINT AREA PRIME FARMLAND 3.78 AC.3.78 AC.3.78 AC. PRIME FARMLAND IF DRAINED 0 AC.0 AC.0 AC. NOT PRIME FARMLAND 16.7 AC.16.7 AC.16.7 AC. FARMLAND OF STATEWIDE IMPORTANCE 0.90 AC.0.90 AC.0.90 AC. TOTAL DISTUBRANCE 21.38 AC.21.38 AC.21.38 AC. PRIME SOILS LEGEND SOIL TYPE 2, PRIME FARMLAND SOIL TYPE 3, FARMLAND OF STATEWIDE IMPORTANCE SCALE: 1" = 100' 0 100 200 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED PRIME SOILS IMPACT PLAN C-800 14 EROSION AND SEDIMENT CONTROL TOPOGRAPHIC FEATURES MINOR CONTOURS (2-FT INTERVAL) MAJOR CONTOURS (10-FT INTERVAL) DRAINAGE ELEMENTS SITE FEATURES OVERHEAD ELECTRICAL UTILITY APPROXIMATE WETLAND AREA ADJACENT PROPERTY BOUNDARY PAVED ROADWAY GRAVEL ROADWAY UNDERGROUND ELECTRICAL UTILITY 8-FT TALL DEER FENCE SOLAR PANEL ARRAY SEED RESTORATION LIMITS GRASSED WATERWAY LAND GRADING ACTIVITIES STABILIZED CONSTRUCTION ENTRANCE DUST CONTROL MEASURESDC AREA OF DISTURBANCE PROPERTY BOUNDARY LEGEND ZONING SETBACK EXISTING PROPOSED NOTES CULVERT STOCKPILE CONCRETE WASHOUT 1320 TREE LINE TREE CUTTING LIMITS (NO GRUBBING OR GROUND DISTURBANCE 0.6' TYP. 1' 4' MIN. SELECT BACKFILL MATERIAL ELECTRIC CONDUIT OR CABLE DETECTABLE WARNING TAPE SAW CUT IF PAVEMENT RESTORE GRADE TO MATCH EXISTING, OR PER SITE PLAN COMPACTED OR UNDISTURBED SOIL1.1 ' MIN. GRAVEL ACCESS ROAD DETAIL NOT TO SCALE MECHANICAL SPECIFICATION Format Weight Front Cover Back Cover Frame Cell Junction box Cable Connector 2416 mm × 1134 mm × 35 mm (including frame) 34.4 kg 2 mm thermally pre-stressed glass with anti-reflection technology 2 mm semi-tempered glass Anodised aluminium 6 × 26 monocrystalline Q.ANTUM solar half cells 53-101 mm × 32-60 mm × 15-18 mm Protection class IP67, with bypass diodes 4 mm² Solar cable; (+) ≥ 700 mm, (−) ≥ 350 mm Stäubli MC4-Evo2, Hanwha Q CELLS HQC4; IP68 35 mm ≥ 350 mm Label 4 × Mounting slots (DETAIL A) 16 mm DETAIL A 21 mm 8.5 mm DETAIL B 22 mm 7 mm 10 mm 1090 mm Frame 1134 mm 1308 mm 2416 mm 400 mm 790 mm 4 × Grounding holes, Ø 4.5 mm 8 × Mounting slots system Tracker (DETAIL B) ≥ 700 mm 1092 mm 554 mm 8 × Drainage holes (3 × 6 mm) 01 - TRANSFORMER 02 - INVERTER 03 - REINFORCED CONCRETE SLAB PSI 3500 04 - AUXILIARY EQUIPMENT PAD Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 9 0 0 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 1 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 ELECTRICAL TRENCH DETAIL NOT TO SCALE SOLAR PANEL MECHANICAL SPECIFICATION DETAIL NOT TO SCALE GENERAL NOTES 1.PROVIDE A 4800 LB/FT ENHANCED WOVEN GEOTEXTILE SEPERATION LAYER AND INSTALL PER MANUFACTURER RECOMMENDATIONS INCLUDING OVERLAPS BASED ON SUB GRADE CBR. 2.THE GEOCELL SHALL BE CONNECTED WITH TYP 3 REBAR J HOOKS. 3.PROVIDE TYP 3 ANCHORS TO KEEP PANELS OPEN FOR INFILL AS REQUIRED 4.GEOCELL INFILL SHALL BE 3 4'' TO 1.5'' CRUSHED AGGREGATE WITH FINE LIMITED TO LESS THAN 10% TO ALLOW FREE DRAINAGE. 5.LIMIT THE DROP OF INFILL TO PREVENT PANEL DISTORTION. 6.ASSUME HS-20 LOADING PERMEABLE ACCESS ROAD GENERAL NOTES 1.USE OF THIS DETAIL/CRITERION IS LIMITED TO ACCESS ROADS USED ON AN OCCASIONAL BASIS ONLY (I.E. PROVIDE ACCESS FOR MOWING EQUIPMENT REPAIR OR MAINTENANCE, ETC.) 2.LIIMITED USE PERVIOUS ACCESS ROAD IS LIMITED TO LOW IMPACT IRREGULAR MAINTENANCE ACCESS ASSOCIATED WITH RENEWABLE ENERGY PROJECTS IN NEW YORK STATE. 3.REMOVE STUMPS, ROCKS AND DEBRIS AS NECESSARY, FILL VOIDS TO MATCH EXISTING NATIVE SOILS AND COMPACTION LEVEL. 4.REMOVED TOPSOIL MAY BE SPREAD IN ADJACENT AREAS AS DIRECTED BY THE PROJECT ENGINEER. COMPACT TO THE DEGREE OF THE NATIVE INSITU SOIL. DO NOT PLACE IN AN AREA THAT IMPEDES STORMWATER DRAINAGE. 5.GRADE ROADWAY, WHERE NECESSARY TO NATIVE SOIL AND DESIRED ELEVATION MINOR GRADING FOR CROSS SLOPE CUT AND FILL MAY BE REQUIRED 6.REMOVE 6'' TO 8'' TOPSOIL AS DIRECTED BY ENGINEER. 7.REMOVE REFUSE SOILS AS DIRECTED BY THE PROJECT ENGINEER. DO NOT PLACE IN AN ARE THAT IMPEDES STORMWATER DRAINAGE. 8.ROADWAY WIDTH TO BE DETERMINED BY CLIENT. 9.THE LIMITED USE PERVIOUS ACCESS ROAD CROSS SLOPE SHALL BE 0% IN MOST CASES AND SHOULD NOT EXCEED 5%. THE LONGITUDINAL SLOPE OF THE ACCESS DRIVE SHOULD NOT EXCEED 5%. 10.LIMITED USE PERVIOUS ACCESS ROAD IS NOT INTENDED TO BE UTILIZED FOR CONSTRUCTION WHICH MAY SUBJECT THE ACCESS TO SEDIMENT TRACKING. THIS SPECIFICATION IS TO BE DEVELOPED FOR POST-CONSTRUCTION USE, SOIL RESTORATION PRACTICES MAY BE APPLICABLE TO RESTORE CONSTRUCTION RELATED COMPACTION TO PRE-EXISTING CONDITIONS AND SHOULD BE VERIFIED BY SOIL PENETROMETER READINGS. THE PENETROMETER READINGS SHALL BE COMPARED TO THE RESPECTIVE RECORDED READINGS TAKEN PRIOR TO CONSTRUCTION, EVERY 100 LINEAR FEET ALONG THE PROPOSED ROADWAY. 11.TO ENSURE THAT SOIL IS NOT TRACKED ONTO THE LIMITED USE PERVIOUS ACCESS ROAD, IT SHALL NOT BE USED BY CONSTRUCTION VEHICLES TRANSPORTING SOIL, FILL MATERIAL, ETC. IF THE LIMITED USE PERVIOUS ACCESS IS COMPLETED DURING INITIAL PHASES OF CONSTRICTION, A STANDARD NEW YORK STATE STABILIZED CONSTRUCTION ACCESS SHALL BE CONSTRUCTED AND UTILIZED TO REMOVE SEDIMENT FROM CONSTRUCTION VEHICLES AND EQUIPMENT PRIOR TO ENTERING THE LIMITED USE PERVIOUS ACCESS ROAD FROM ANY LOCATION ON, OR OFF SITE. MAINTENANCE OF THE PERVIOUS ACCESS ROAD WILL BE REQUIRED IF SEDIMENT IS OBSERVED WITHIN THE CLEAN STONE. 12.THE LIMITED USE PERVIOUS ACCESS ROAD SHALL NOT BE CONSTRUCTED OR USED UNTIL ALL AREAS SUBJECT TO RUNOFF ONTO THE PERVIOUS ACCESS HAVE ACHIEVED FINAL STABILIZATION. 13.PROJECTS SHOULD AVIOD INSTILLATION OF THE LIMITED USE PERVIOUS ACCESS ROAD IN POORLY DRAINED AREAS, HOWEVER IF NO A 14. THE DESIGN PROFESSIONAL MUST ACCOUNT FOR THE LIMITED USE PERVIOUS ACCESS ROAD IN THEIR SITE ASSESSMMENT/HYDROLOGY ANALYSIS. IF THE HYDROLOGY ANALYSIS SHOWS THAT THE HYDROLOGY HAS BEEN ALTERED FROM PRE- TO POST-DEVELOPMENT CONDITIONS (SEE APPENDIX A OF GP-0-20-001 FOR THE DEFINITION OF "ALTER THE HYDROLOGY..."), THE DESIGN MUST INCLUDE THE NECESSARY DETENTION/RETENTION PRACTICES TO ATTENUATE THE RATES (10 AND 100 YEAR EVENTS) TO PRE-DEVELOPMENT CONDITIONS. GEOCELL MATERIAL NOTES: 1.THE GEOCELL, OR COMPARABLE PRODUCT, IS SUGGESTED FOR USE ON ROAD PROFILES EXCEEDING 5%. THE GEOCELL PRODUCT IS INTENDED TO LIMIT SHIFTING STONE MATERIAL DURING USE. 2.INSTILLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 3.WHERE REQUIRED, A NATIVE SOIL WEDGE SHALL BE PLACED TO ACCOMODATE ROAD CROSS SLOPE OF 2%. NATIVE SOIL SHALL BE COMPACTED TO MATCH EXISTING SOIL CONDITIONS. 4.GRAVEL FILL MATERIAL SHALL CONSIST OF 1-4'' CLEAN, DURABLE, SHARP-ANGLED CRUSHED STONE OF UNIFORM QUALITY, MEETING THE SPECIFICATIONS OF NYSDOT ITEM 703-02, SIZE DESIGNATION 3-5 OF TABLE 703-4. STONE MAY BE PLACED IN FRONT OF, AND SPREAD WITH, A TRACKED VEHICLE. GRAVEL SHALL NOT BE COMPACTED. 5.GEOCELL SYSTEM SHALL BE CARTHAGE MILLS CX-20 6'' HS20 LOADING OR APPROVED EQUAL. GEOCELL SHALL BE DESIGNED BASED ON EXISTING SOIL CONDITIONS AND PROPOSED HAUL ROAD SLOPES. 6.LIMITED USE PERVIOUS ACCESS ROAD SHALL BE TOP DRESSED AS REQUIRED WITH ONLY 1-4'' CRUSHED STONE, SIZE 3A, MEETING NYSDOT ITEM 703-02 SPECIFICATIONS. 7.THE TOP EDGES OF ADJACENT CELL WALLS SHALL BE FLUSH WHEN CONNECTING. ALIGN THE I-SLOTS FOR INTERLEAF AND END TO END CONNECTIONS. THE GEOCELL PANELS SHALL BE CONNECTED WITH TYPE 3 J HOOKS AT EACH INTERLEAD AND END TO END CONNECTIONS. REFER TO MANUFACTURER'S SPECIFICATION FOR PROPER INSTILLATION. TYING AND CONNECTIONS. 8.[PREPARE THE SUBGRADE AS SHOWN ON THE CONSTRUCTION DRAWINGS. 9.COMPACT THE SOIL TO A MINIMUM 95% STANDARD PROCTOR. 10.VERIFY THAT THE SUBGRADE STRENGTH. IF UNACCEPPTABLE, THE SOILS SHALL BE REMOVED AND REPLACED AS DIRECTED BY THE ENGINEER. 11.WHERE REQUIRED, PROVIDE GEOTEXTILE SEPARATION LAYER. 12.EXPAND THE GEOCELL SECTIONS INTO POSITION AND CONNECT THE END TO END INTERLEAD CONNECTIONS WITH ATRA KEYS. 13.PLACE THE SPECIFIED INFILL MATERIAL TO 2 INCHES ABOVE CELL WALLS AND COMPACT TO A MINIMUM 95% STANDARD PROCTOR. 14.PROVIDE ADDITIONAL SURFACE MATERIAL AS SPECIFIED. BASIS OF DESIGN: CARTHAGE MILL WOVEN GEOTEXTILE MATERIAL NOTES: 1.GEOTEXTILE MATERIAL TO B CARTHAGE MILL FX-60HS OR APPROVED EQUAL. BASIS OF DESIGN: CARTHAGE MILLS EXISTING ELEVATION ROADSIDE SWALE, TYP. BOTH SIDES RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED SITE DETAILS C-900 15 8-FT DEER FENCE DETAIL SCALE: NOT TO SCALE BRACING NOTES 1.BRACING IS REQUIRED AT ALL CORNER, END GATE, AND PULL ASSEMBLIES IN THE FENCE. 2.CORNERS ARE REQUIRED AT ALL POINTS WHERE THE FENCE ALIGNMENT CHANGES 15 DEGREES OR MORE THREE, 6 IN. X 16 FT. VERTICAL POSTS AND TWO 5 IN. X 16 FT. HORIZONTAL BRACES ARE REQUIRED FOR EACH CORNER. 3.END BRACING IS REQUIRED WHERE THE FENCE ENDS AT A BUILDING OR ON EACH SIDE OF A GATE OPENING. TWO, 6 IN X 16 FT. VERTICAL POSTS AND ONE 5 IN. X 16 FT. HORIZONTAL BRACE ARE REQUIRED FOR EACH END BRACE. 4.PULL ASSEMBLIES ARE REQUIRED IN STRAIGHT SECTIONS OF FENCE SO THAT THE MAXIMUM DISTANCE BETWEEN CORNERS DOES NOT EXCEED 1,320 DT. TWO 6 IN. X 16 FT. VERTICAL POSTS AND ONE 5 IN. X 16 FT. BRACE ARE REQUIRED. 5.DOUBLE BRACES (FIGURE 4) SHOULD BE USED ON EACH END FOR STRAIGHT FENCE LINES EXCEEDING 1,000 FT. DOUBLE END BRACES REQUIRE THREE 6 IN. X 16 FT. HORIZONTAL BRACES. 6.FENCE SHALL HAVE A MINIMUM HEIGHT OF 8 FT. 7.A 5' GAP FROM GRADE TO THE BOTTOM OF THE FENCE TO ALLOW FOR THE MOVEMENT OF SMALL ANIMALS. WARNING ANYONE DAMAGING, VANDALIZING, OR INTERFERING WITH THE OPERATION OF THIS FACILITY IS IN VIOLATION OF TITLE 18. UNITED STATES CODE SECTION 1366 AND PUNISHABLE BY 10 YEARS IMPRISONMENT AND $50,000 FINE. NOTICE IN CASE OF EMERGENCY CALL ( )-___-____ BLUE BARNS SOLAR ARRAY COMPANY, LLC 24HR EMERGENCY CONTRACT NAME, PHONE, ADDRESS DANGER HIGH VOLTAGE KEEP OUT NO TRESSPASSING PRIVATE PROPERTY. UNAUTHORIZED ENTRY PROHIBITED VIOLATORS WILL BE PROSECUTED UNDER AUTHORITY OF THE STATE OF NEW YORK PENAL LAW SECTION 140.10 THESE FACILITIES ARE MONITORED BY VIDEO & ELECTRONIC SECURITY EQUIPMENT WARNING SIGNAGE DETAIL SCALE: NOT TO SCALE 5"Ø x 16" PRESSURE TREATED POST (TYP.) OR 3" O.D. GALVANIZED STEEL POST, OR APPROVED EQUAL 6" Ø x 16' PRESSURE TREATED RED PINE POST, TYP. OR 3" O.D. GALVANIZED STEEL POST OR APPROVED EQUAL 6'-8" 16' BRACE SPACING (TYP.) 12.5 GAUGE CLASS 3 GALVANIZED HIGH TENSILE BRACE WIRE (MIN TENSILE STRENGTH OF 170,000 LBS) DONALDS OR ROBERSTON WIRE STRAINER WIDTH 1/2" Ø SQUARE HUB OR APPROVED EQUAL MAINTAIN A MINIMUM 6" WILDLIFE GATE UNDER FENCE BRACE WIRE TO FROM A DOUBLE LOOP IN A FIGURE EIGHT FASHION POSITION OVER THE BRACE PIN AT THE TOP AND IS HELD IN PLACE BY FENCE STABLES AT THE BOTTOM. THE STABLE SHOULD BE SET WITH SUFFICIENT SPACE TO ALLOW THE WIRE TO BE THREADED THROUGH - DO NOT SET THEM TIGHT BARBED STABLES MINIMUM 9 GAUGE, CLASS 3 GALVANIZED 1-3/4 IN. LONG. THE TOP AND BOTTOM TWO HORIZONTAL WIRE TO BE STAPLED TO LINE POST WITH AN ADDITIONAL 6 STAPLES IN A RANDOM ALTERNATION PATTERN 10" GALVANIZED LANDSCAPE SPIKE OR PIN 8' HIGH TENSILE 12 5 GAUGE. HIGH TENSILE WIRE, CLASS 3 GALVANIZED. WOVEN WIRE TO BE COMPRISED OF 20 HORIZONTAL WIRE. ASSEMBLED WITH VERTICAL STAY WIRE 12 IN. APART 4"Ø X 14' PRESSURE TREATED POST (TYP.) OR 3" O/D. GALVANIZED STEEL POST, OR APPROVED EQUAL20' LINE SPACING (TYP.) FINISH GROUND SURFACE EXISTING SUBGRADE ALL POST TO BE SET USING A MECHANICAL POST DRIVER LINE POST TO BE SET 4' DEEP NO TRESSPASSING PRIVATE PROPERTY. UNAUTHORIZED ENTRY PROHIBITED VIOLATORS WILL BE PROSECUTED UNDER AUTHORITY OF THE STATE OF NEW YORK PENAL LAW SECTION 140.10 WARNING ANYONE DAMAGING, VANDALIZING, OR INTERFERING WITH THE OPERATION OF THIS FACILITY IS IN VIOLATION OF TITLE 18. UNITED STATES CODE SECTION 1366 AND PUNISHABLE BY 10 YEARS IMPRISONMENT AND $50,000 FINE. DANGER HIGH VOLTAGE KEEP OUT THESE FACILITIES ARE MONITORED BY VIDEO & ELECTRONIC SECURITY EQUIPMENT WARNING NOTICE IN CASE OF EMERGENCY CALL ( )-___-____ 3" 3" 4'-8" REFER TO SIGNAGE DETAIL DEER FENCE GATE NOTE(S): 1.GATE SHALL BE SELF LOCKING 2.OPERATOR IDENTIFICATION AND TELEPHONE NUMBER SHALL BE PROVIDED, AND OPERATOR MUST BE AVAILABLE FOR CONTACT ON A 24/7 BASIS. 8-FT DEER FENCE GATE DETAIL NOT TO SCALE HEAVY DUTY GALVANIZED 8' x 12' GATE WITH 4" x 4" MESH PANELS WELDED, TYP. HEAVY DUTY GALVANIZED 3 4" PINTLE GATE HINGE, TYP. 3 EACH GATE 1 5 8" ROUND TUBULAR GALVANIZED FRAMING 6" Ø x 16' PRESSURE TREATED RED PINE POST, TYP. OR 3" O.D. GALVANIZED STEEL POST OR APPROVED EQUAL GATE POST, TYP. LATCH IN OPEN POSITION LOCKING TANG LOCKING TANG GATE LATCH MAINTAIN 4" SPACING UNDER GATES 10" MIN.12' GATE WIDTH 12' GATE WIDTH 2" TO 4" SPACING 8' DONALDS WIRE STRAINER OR APPROVED EQUAL 12.5 GUAGE CLASS 3 GALVANIZED HIGH TENSILE BRACE WIRE (MIN TENSILE STRENGTH OF 170,000 LBS) PROVIDE KNOCK BOX AND COORDINATE WITH LOCAL EMERGENCY SERVICES GATE LATCH THESE FACILITIES ARE MONITORED BY VIDEO & ELECTRONIC SECURITY EQUIPMENT WARNINGWARNING ANYONE DAMAGING, VANDALIZING, OR INTERFERING WITH THE OPERATION OF THIS FACILITY IS IN VIOLATION OF TITLE 18. UNITED STATES CODE SECTION 1366 AND PUNISHABLE BY 10 YEARS IMPRISONMENT AND $50,000 FINE. NO TRESSPASSING PRIVATE PROPERTY. UNAUTHORIZED ENTRY PROHIBITED VIOLATORS WILL BE PROSECUTED UNDER AUTHORITY OF THE STATE OF NEW YORK PENAL LAW SECTION 140.10 NOTICE IN CASE OF EMERGENCY CALL ( )-___-____ BLUE BARNS SOLAR ARRAY COMPANY, LLC 24HR EMERGENCY CONTRACT NAME, PHONE, ADDRESS DANGER HIGH VOLTAGE KEEP OUT 3" 3" 8" CONCRETE SLAB WITH TWO LAYERS OF 6"x6" 10/10 WELDED WIRE MESH WWM MIN 24" OF BACKFILL CONCRETE EQUIPMENT PAD DETAIL NOT TO SCALE 12'MIN. 50'MIN. 6"MIN. 50'MIN. 12'MIN. 10'MIN. 10'MIN. INSTALLATION NOTES 1.AREA CHOSEN FOR STOCKPILING OPERATIONS SHALL BE DRY AND STABLE. 2.MAXIMUM SLOPE OF STOCKPILE SHALL BE 2:1. 3.UPON COMPLETION OF SOIL STOCKPILING, EACH PILE SHALL BE SURROUNDED WITH EITHER SILT FENCING OR STRAWBALES, THEN STABILIZED WITH VEGETATION OR COVERED. 4.SEE SILT FENCE DETAIL ABOVE. 5.SILT FENCE TO BE 10' FROM TOE OF SLOPE AND 10' FROM PROPERTY LINES. 2% M I N . SLO P E 2 % M I N . S L O P E SLOPE OR LESS 1 2 STABILIZE ENTIRE PILE WITH VEGETATION OR COVER SILT FENCE (WITH WIRE FENCING SUPPORT IN SLOPES > 2:1) TEMPORARY SEED FERTILIZER: COMMERCIAL 5-10-5, 175 POUNDS PER ACRE TOP SOILTOP SOIL MULCH: LAYER OF COMMON HAY OR STRAW: 2 TONS PER ACRE APPLY LIME TO BRING SOIL PH TO 6.5 CONSTRUCTION SPECIFICATIONS 1.TOP SOIL, SEED, MULCH, AND FERTILIZER DISTURBED SOIL AREAS THAT WILL BE EXPOSED FOR 14 DAYS OR MORE CONSTRUCTION SPECIFICATIONS ‘’ WINTER RYE HYDRAULICALLY APPLIED BLANKETS ’ ≥ ’ CONSTRUCTION SPECIFICATIONS Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 9 0 1 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 1 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 WINTER SHUTDOWN CONSTRUCTION SCHEDULE 1.POST CLEARING THE EXPOSED SOIL SHALL BE COVERED WITH MATERIAL(S) AS SET FORTH IN THE TECHNICAL STANDARD, NEW YORK STANDARDS AND SPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL, TO PREVENT THE EXPOSED SOIL FROM ERODING (SEE STANDARD AND SPECIFICATIONS FOR TEMPORARY CONSTRUCTION AREA SEEDING/STABILIZATION FOR WINTER SHUT DOWN, ABOVE). 2.REGULARLY INSPECT, MAINTAIN AND RE-SEED ANY AREAS THAT ARE NOT ADEQUATELY STABILIZED UP UNTIL THE JULY 1 START DATE AND THEREAFTER, UNTIL ALL DISTURBED AREAS ARE PERMANENTLY STABILIZED. 3.SITE INSPECTIONS ARE TO TAKE PLACE TWICE PER MONTH WITH PHOTOS PROVIDED TO THE TOWN TO DEMONSTRATE THAT THE SITE REMAINS STABILIZED/PROTECTED UNTIL CONSTRUCTION STARTS. 4.ONCE CONSTRUCTION STARTS, INSPECTIONS SHALL CONTINUE MONTHLY, WITH PHOTOS SUBMITTED TO THE TOWN, TO ENSURE THAT THE TEMPORARY STABILIZATION MEASURES REMAIN IN PLACE IN AREAS NOT UNDER ACTIVE CONSTRUCTION. NORTHEAST SOLAR POLLINATOR 3' MIX - ERNMX-612 SHEEP FESCUE, VARIETY NOT STATED 94.90% BUTTERFLY MILKWEED 2.50% PARTRIDGE PEA, PA ECOTYPE 2.00% SHOWY EVENING PRIMROSE 0.30% ZIGZAG SPIDERWORT, VA ECOTYPE 0.30% SEEDING NOTE: 1. ERNEST CONSERVATION SEEDS NORTHEAST POLLINATOR 3' MIX - ERNMX-612 TO BE SEEDED BELOW SOLAR PANELS. SEED AT 40 LB/AC WITH 30 LB/AC OF A COVER CROP. FOR A COVER CROP USE EITHER GRAIN OATS (1 JAN TO 31 JUL) OR GRAIN RYE (1 AUG TO 31 DEC). 2.FOLLOWING SEEDING APPLY AIR-DRIED HAY OR STRAW MULCH FREE OF UNDESIREABLE SEED AND COURSE MATERIALS AT A RATE OF TWO TONS (100-120 BALES) PER ACRE. SIGNAGE DETAIL NOT TO SCALE SIGNAGE NOTE: 1. SIGNAGE SHALL BE DEPICTED WITH AN AREA NO MORE THAN 8 SQUARE FEET AND MUST HAVE A YELLOW BACKGROUND WITH BLACK LETTERS AND BE LOCATED NEAR PAD MOUNTED TRANSFORMERS/SUBSTATION, ON THE GATE OF THE PERIMETER FENCE, AND ALONG THE PERIMETER FENCE. PRUNE 1/5 OF GROWTH & NATURAL FORM OF SHRUB RETAIN LEADERS AND BROKEN BRANCHES BUT 3. IF BALLED & BURLAPPED, REMOVE TOP 1/3 OF BURLAP. AS EXISTED AT NURSERY. 2. SHRUB SHALL HAVE SAME RELATION TO FINISH GRADE 1. SPRAY ALL PLANTS WITH ANTI-DESSICANT. NOTES: EARTH SAUCER 3" MULCH WITHIN 6" MIN. MIN.MIN. A.A.N. STD. AS PER A.A.N. STD. AS PER 6"A.A.N. STD. AS PER 6" BALL ROOT WEED BARRIER BALL ROOT UNDISTURBED EARTH TOPSOIL MIXTURE EVERGREEN TREE BR A N C H I N G H E I G H T 6' - 0 ' ' M I N . FINISH GRADE SET TOP OF ROOTBALL 1'' ABOVE BALL DIA. x 2 MIN. SHREDDED BARK MULCH AT 4" DEPTH PREPARED PLANTING MIXTURE OF BALL. DE P T H BA L L TREE BALL, IF PRESENT.REMOVE ALL PLASTIC CORDS FROM DO NOT CUT BURLAP FROM SIDES REMOVE ALL PLASTIC & WIRE TABS. NOTES: FG SOIL SAUCER, TOP W/ MULCH BALL DIA. 4'' DEPTH OF COMPOST, INSTALL AND MIX W/PLANTING BACKFILL MIXTURE DO NOT EXCAVATE LOWER THAN BALL DEPTH. IF ECAVATED BELOW THE BALL DEPTH BACKFILL AND COMPACT TO PREVENT SETTLEMENT. REMOVE BURLAP FROM TOP 1/3 OF PLANTING BALL 25% COMPOST 75% TOPSOIL PH RANGE: 6.7 TO 7.0 5 LBS. TYPE 1 -ROOT GROWTH ENHANCER PER CUBIC YARD OF MIXTURE RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED EROSION AND SEDIMENT CONTROL DETAILS C-901 16 SHEET FLOW MAXIMUM OVERALL SLOPE NOT TO EXCEED 8% LEVEL SPREADER (WHERE NECESSARY) SEEDED PER UPLAND SEED MIX SPECIFICATION FILTER STRIP LENGTH PER SOIL/SLOPE/COVER REQUIREMENTS GRADED, UNCOMPACTED OR LIGHTLY COMPACTED SUBGRADE MINIMUM TOPSOIL DEPTH 8" FIRST 10 FT OF FILTER TO BE LESS THAN 2% SLOPE REQUIRED ELEMENTS: 1.MAXIMUM CONTRIBUTING LENGTH SHALL BE 150 FEET FOR PERVIOUS AND 75 FEET FOR IMPERVIOUS SURFACES. 2.RUNOFF SHALL ENTER THE BUFFER AS OVERLAND SHEET FLOW; A FLOW SPREADER CAN BE SUPPLIED TO ENSURE THIS, IF AVERAGE CONTRIBUTING SLOPE CRITERIA CANNOT BE MET (NOTE: A LEVEL SPREADER SHALL BE USED BETWEEN BUFFER SLOPES RANGING BETWEEN 3% AND 15%; FOR BUFFER SLOPES BEYOND 15% THIS PRACTICE CANNOT BE APPLIED) 3.MINIMUM WIDTH OF A VEGETATED FILTER STRIP OR UNDISTURBED RIPARIAN BUFFER SHALL BE 50 FEET FOR SLOPES OF 0% TO 8%, 75 FEET FOR SLOPES OF 8% TO 12% AND 100 FEET FOR SLOPES OF 12% TO 15%. 4.BUFFERS MUST BE FILLY VEGETATED. 5.SITTING AND SIZING OF THE PRACTICE SHOULD ADDRESS WQV AND RUNOFF REDUCTION REQUIREMENTS AND CANNOT RESULT IN OVERFLOW TO UNDESIGNATED AREAS. NOTE: IN HSG C AND D BUFFER LENGTH SHOULD BE INCREASED BY 15%-20% RESPECTIVELY. GRASS FILTER STRIP DETAIL SCALE: NOT TO SCALE 1' 1' Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 9 0 2 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 1 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED DRAINAGE DETAILS C-902 17 CULVERT DETAIL NOT TO SCALE EDGE OF CRUSHED STONE BASE EXTENDS 1' PAST ROOF EDGE ZONE CONTROLLER MAST CORRUGATED METAL ROOF WITH RIDGE SEAM / FLASHING Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 9 0 3 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 1 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 SOLAR TRACKER SPECIFICATIONS NOT TO SCALE INVERTER SPECIFICATIONS NOT TO SCALE SOLAR PANEL SPECIFICATIONS NOT TO SCALE MI N I M U M CL E A R A N C E 3 ' Mi n i m u m m o d u l e cl e a r a n c e ± 1 / 2 " Purlin per table schedules Pivot arm [S7340] (4) 3/8" x 3/4" HH Galv. Bolt & Nut [2GB37X075HH] WITH 3/8" Galv. Washer [2W37GALV] and 3/8" Galv. Lock washer [2W37GALV-LOCK] PV Module Pivot arm purlin clip each end [ (2) S7342-7] FRONT VIEW Post per post schedule(s) on REAR VIEW Component layout sheet(s) Lever arm Mounting plate beyond PV Module Gear Box DETAIL 3 DETAIL 5 PV Module in rotated position PV Module in stowed position DETAIL 5 Pivot arm per table schedule(s) Purlin per stowed position schedule(s) DETAIL 3 Post per post schedule(s) ±0.00 @6 0 . 0 0 ° MA X I M U M CL E A R A N C E 1 1 ' CL E A R A N C E 7 ' TRACKER SOLAR ARRAY DETAIL SCALE: NOT TO SCALE INVERTER BANK DETAIL SCALE: NOT TO SCALE PLACE 18" SERVICE LOOP ON THIS UNISTRUT RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED EQUIPMENT SPECIFICATION C-903 18 4" DEPTH OF CRUSHED STONE BASE EXTENDS 1' PAST ROOF EDGE Drawing Number: Sheet of PWGC Project Number: Title of Drawing: Client: Regulatory Reference Number: County Tax Map Number: Number Revision Description Revision Date Project: Project Address: Unauthorized alteration or addition to this drawing and related documents is a violation of Section 7209 of the New York State Education Law CONSULTANTS Approved By Drawn By Designed By Scale Date Created Date Submitted PW G C F I L E N A M E : J : \ P r o j e c t s A - D \ B R R \ B R R 2 4 0 6 - S o u t h S o u t h M a i n S t r e e t \ C A D \ B R R 2 4 0 6 - S o u t h M a i n S t r e e t S o u t h P a r c e l 0 7 . 0 3 . 2 5 . d w g ( C - 9 0 4 ) PL O T D A T E / T I M E : J u l 0 3 , 2 0 2 5 - 2 : 2 1 p m B y : r v a u g h n Contract Number: 1 2 3 4 5 6 7 630 Johnson Avenue. ●Suite 7 Bohemia ●NY ●11716-2618 Phone: (631) 589-6353 ●Fax: (631) 589-8705 E-mail: INFO@PWGROSSER.COM CLIENT DRIVEN SOLUTIONS PWGC P.W. GROSSER CONSULTING INC. 8 NY GROTON II (SOUTH MAIN STREET), LLC P.O. BOX 384 CALLICOON, NEW YORK 12783 SOUTH MAIN STREET, EXT. SOUTH PARCEL SOLAR FARM CONCEPTUAL PLAN SOUTH MAIN STREET TOWN OF GROTON TOMPKINS COUNTY, NEW YORK 31-1-12.1 --- --- 19 BRR2406 TOWN REVIEW 04/16/2025 ISSUED FOR CONSTRUCTION 06/17/2025 DR A F T REVISED PER CLIENT REVIEW 06/27/2025 NYSDAM REVISION 07/03/2025 SCALE: N/A1 SCALE: N/A2 SCALE: N/A3 SCALE: N/A4 GROUND GRID & SWITCH HANDLE GROUNDING DEATILS SCALE: N/A6 POLE C1-CUSTOMER OWNED POLE WITH MAIN SERVICE DISCONNECT, C511 GANG OPERATED AIR BREAK POLE C2-CUSTOMER OWNED POLE WITH CUSTOMER OWNED RECLOSER, R516 POLE C3-CUSTOMER OWNED POLE WITH UTILITY OWNED METER POLE C4-CUSTOMER OWNED RISER/CUSTOMER METER , POLE WITH 600A SOLID BLADE CUTOUTS, C513 NOTES: 1.REFER TO NATIONAL GRID "SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS" & "SUPPLEMENTS TO THE SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS" FOR ADDITIONAL DETAILS. ANY MODIFICATONS FROM NATIONAL GRIDS STANDARDS MUST BE SUBMITTED AND APPROVED BY NATIONAL GRID PRIOR TO INSTALLATION. 2.ALL NON-CURRENT CARRYING METALLIAC PARTS SHALL BE BONDED TO EQUIPMENT GROUND WITH A STRANDED #4AWG BARE COPPER CONDUCTOR. THIS INCLUDES SWITCH FRAMES, GUY WIRES, SWITCH BASES, AND THE NEUTRAL CONDUCTOR. 3.POLES SHALL BE CLASS 3, FULL LENGTH PENTA TREATMENT, AND CONFORM TO THE STANDARDS OF EEI TD-103 & ANSI O5.1. CROSSARMS SHALL CONFORM TO SPECIFICATIONS OF EEI TD-90. 4.POLES SHALL BE A MINIMUM OF 40' IN HEIGHT, SET AT 6' MINIMUM DEPTH. 5.LOCATIONS AND QUANTITIES OF STRUCTURAL COMPONENTS ARE SUBJECT TO A DELEGATED DESIGN IS REQUIRED TO VERIFY THE STRUCTURAL INTEGRITY OF THE OVERHEAD TRANSMISSION SYSTEM AND SHALL ENCOMPASS ALL OF THE VARIABLE INCLUDING, BUT NOT LIMITED TO: GUY WIRES, ALL POLES & POLE MOUNTED EQUIPMENT, AND WIRING REQUIRED FOR OVERHEAD TRANSMISSION. THE DELEGATED DESIGN SHALL BE COMPLETED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER AND INCLUDED AS PART OF THE SUBMITTAL PROCESS. 6.POLES SHALL BE A MINIMUM OF 25FT APART. REFER TO SITE PLANS FOR EXACT SPACING. 7.REFER TO ESB 752-1994, SERVICE ABOVE 15,000 VOLTS, LARGE COMMERCIAL & INDUSTRIAL FOR REFERENCES TO FIGURES FOR TABLE "OUTDOOR STRUCTURE ELECTRICAL CLEARANCES. OUTDOOR STRUCTURE ELECTRICAL RPV/NRD RPV/NRD 11/15/23 MTS/EJK AS NOTED OVERHEAD ELECTRICAL DETAILS C-904 19