Loading...
HomeMy WebLinkAboutAppendix_C_-_Turbine_Information.pdfThe REpower MM100 is based on the well-established REpower MM series. As such, it incorporates all the experience and expertise derived from our 2,000 operational REpower MM70, MM82 and MM92 wind turbines. 50 Hz: With its longer blades the MM100 produces high yields in low wind speed areas. The increased swept area of the rotor captures the wind more effectively and thus results in excellent returns over the entire service life. 60 Hz: With its high net capacity factor, the new variant has been optimized to achieve rated power even at low wind speeds. This enables the wind farm to secure a constant power supply, making efficient use of the avilable grid capacity. Due to our leading technology and innovative solutions, REpower’s wind turbines are capable of fulfilling the most demanding grid codes. The REpower MM100 has a swept rotor area of 7,854 square meters and is available with a hub height from 80 m to 100 m. It has been specifically optimized for use in regions with low wind speeds and operates with an outstanding low sound power level of max. 104.8 dB(A). By choosing REpower turbines, you are selecting power plant technology of the highest quality. To ensure that your investment retains its value, we offer comprehensive after-sales service. Our permanent monitoring system monitors your power plants 365 days a year, 24 hours a day. This guarantees that our locally based service teams respond in the shortest time possible. We also offer integrated service packages (ISP-onshore and OSP-offshore) that allow our customers to set long-term operating costs. We are constantly upgrading our services to meet the increasingly stringent requirements of monitoring, documenting and optimizing the operational behavior of wind farms. Our REguard package offers a comprehensive modular windfarm management system that can be flexibly configured to suit local factors, ensuring efficient operation of your plant at all times. For more information, please refer to our brochures or contact our sales team for a personal consultation. Powerful, economical, reliable The reliable megawatt power plant with 100 meter rotor diameter Makes the most of low wind speedsMakes the most of low wind speeds 2,200.0 2,000.0 1,800.0 1,600.0 1,400.0 1,200.0 1,000.0 800.0 600.0 400.0 200.0 0.0electrical power (kW)wind speed at hub height (m/s)3.04.05.06.0 7.0 8.0 9.010.011.012.013.02,200.0 2,000.0 1,800.0 1,600.0 1,400.0 1,200.0 1,000.0 800.0 600.0 400.0 200.0 0.0electrical power (kW)wind speed at hub height (m/s)3.04.05.06.0 7.0 8.0 9.010.011.012.013.0Electrical power curve: 50 Hz Electrical power curve: 60 Hz The reliable megawatt power plant with 100 meter rotor diameter Powerful, economical, reliable The REpower sales teams are always there for you. USA · 03/ 2012 REpower Systems SE · Headquarters · Überseering 10 · 22297 Hamburg · Germany Phone: +49-40-55550 90-0 · Fax: +49-40-55550 90-39 99 E-mail: info@repower.de · www.repower.de Please visit our website: at www.repower.de About us Locations you can find the addresses of all our company sites. All information contained in this product brochure are subject to change at any time. REpower assumes no liability for any errors or omissions in the content of this product brochure. No guarantees are given. Any scope of services and supply shall be determined exclusively by a formal agreement. The REpower sales teams are always there for you. Europe REpower Australia Pty Ltd Melbourne Australia REpower North (China) Co. Ltd Baotou REpower Wind Systems Trading (Beijing) Co. Ltd Asia REpower Italia S.r.l. Milan REpower Portugal S.A. Porto Projectmanagement, Support Centre and Service Büdelsdorf Production, Service Husum REpower S.A.S. Paris La Défense REpower España S.L. Madrid REpower UK Ltd Edinburgh TechCenter Osterrönfeld Headquarters and REpower Systems GmbH Hamburg Production Bremerhaven and PowerBlades GmbH REpower Systems Scandinavia AB Västerås REpower Systems Polska Sp. z o.o. Warsaw Production, Service Trampe and Eberswalde Development Center Osnabrück REpower Benelux bvba. Oostende REpower Systems Northern Europe A/S Aarhus America REpower USA Corp. Denver, Colorado REpower Systems Inc. Toronto REpower Canada Inc. Québec, Montreal Printed on certified paper from sustainably managed forests. Design data Rated power 1,800 kW (60 Hz) 2,000 kW (50 Hz) Cut-in speed 3.0 m/s Rated wind speed 10.5 m/s (60 Hz) 11.0 m/s (50 Hz) Cut-out speed 22.0 m/s Type class IEC S class (IEC IIIA annual wind, IEC IIA extreme wind) Rotor Diameter 100 m Rotor area 7,854 m2 Rotor speed 7.8–13.89 rpm (+12.5%) Rotor blade Length 48.9 m Type GRP sandwich construction; manufactured in Infusion-process Yaw system Type Double-row externally geared four-point bearing Drive system Gear motors Stabilization Disc brakes Gear system Type Combined planetary/spur wheel gearbox Transmission ratio i = approx. 103.7 (60 Hz) i = approx. 129.6 (50 Hz) Electrical system Generator type Double-fed asynchronous generator, 6-pole (60 Hz) 4-pole (50 Hz) Rated power 1,800 kW (60 Hz) 2,000 kW (50 Hz) Rated voltage 575 V (60 Hz) 690 V (50 Hz) Rated speed 720 -1,440 rpm (60 Hz) 900 -1,800 rpm (50 Hz) Generator protection class IP 54 Converter type Pulse width-modulated IGBTs Power control Principle Electrical blade angle adjustment – pitch and speed control Sound power level LWA, 95% 104.8 dB (A) Tower Type Steel tube Hub height 80 m/100 m Foundation Reinforced concrete foundation with foundation insert (depending on hub height), adjusted to site conditions Safety system Individually adjustable blades (electrically controlled) – fail-safe system Extensive redundant temperature and speed sensing system Fully integrated lightning protection Shielded cables and power rails protecting people and machinery Rotor holding brake with soft-brake function Environment No leakage of lubricants at hub or nacelle, due to - labyrinth packing in spinner - coaming edges in nacelle panelling and - grease pan below azimuth gearing Closed central lubrication system for blade bearings Shielding of all relevant cables and use of power rails to protect workers and machine Holding brake Secure holding of rotor due to generously dimensioned disc brake Soft-brake function reducing stress to the gearbox Gear system Combined planetary/spur wheel gearbox Dimensioned according to REpower gear regulations, meeting the most stringent requirements regarding service life and smooth running Integrated oil particle counter Optimized efficiency Elastomer bearing on torque multiplier for structure-borne sound insulation Low temperature level due to effective oil cooling system Excellent oil quality due to three-stage oil filter system Lightning protection Lightning protection concept conforming to IEC regulations with internal and external lightning protection External lightning protection system with blade receptors and lightning rod at the weather mast Reliable protection of bearings due to defined lightning conduits GFC coupling for the galvanic insulation of the generator system from the gear system Over-voltage arrester protecting the electric system Reliable protection of the generator by means of insulated bearing bushings Serviceability Ample space in nacelle for ergonomically optimized and reliable service Hub easily accessible in all weather without having to leave the nacelle Excellent accessibility of all components Guards mounted over all rotating components ensure safe servicing If necessary, virtually all components of the plant can be easily and safely dismantled Pitch system Virtually maintenance-free electronic system High-quality, generously dimensioned blade bearing with permanent track lubrication Protected against the elements by means of integrated deflector in the spinner Maximum reliability via redundant blade angle detection by means of two separate measuring systems Fail-safe design with separate control and regulation systems for each rotor blade Rotor hub Low deformation due to compact design adjusted to power flow Optimized integration into pitch drive Generously dimensioned spinner allowing access to the hub in all weather Power rail Prevention of electrical interference in the plant Compliance with VDE regulations Best possible protection in the event of a short circuit or fire Tube tower Characteristic frequency of the tower is above rotating frequency of the rotor (rigid design) and ensures minimum stress in tower and machine No restrictions regarding speed range of unit, as there is no risk of frequency interference Excellent component safety due to elbow flanges and load-optimized door opening Rotor bearing and shaft High-performance spherical roller bearing with adjusted bearing housing and permanent lubrication for prolonged service life Rotor shaft forged from heat-treated steel and optimized for power flow Generator and converter Yield-optimized variable speed range Low conversion loss and high total efficiency as converter output is limited to maximum 20% of the overall output Fully enclosed generator with air/air heat exchanger Optimized temperature level in generator, even at high outside temperatures Yaw Externally geared four-point bearing, driven by generously dimensioned high-quality gear motors Holding brakes with fail-safe function implemented with hydraulic pressure accumulator release the drives in idle mode and stabilize the nacelle Minimal load on drives due to low friction at four-point bearing and release of brakes during tracking Technical DataTechnical Data