Loading...
HomeMy WebLinkAboutPVSyst_Enfield_SATled 111 , vsl PH O TO V O LTA I C SO F T W A RE Version 7.1.4 PVsyst - Simulation report Grid -Connected System Project: Norbut - Enfield Variant: BV400 CPS125 SAT Tracking system with backtracking System power: 7498 kWp Enfield_SA34_GHIAvgmths - United States Author Namaste Solar (United States) 888 Federal Blvd Denver/80204 USA Project summary Geographical Site Situation Meteo data Enfield_SA34_GHIAvgmths Latitude 42.45 °N Enfield_SA34_GHIAvgmths United States Longitude -76.65 °W SA34: TGY - TMY Altitude 387 m Time zone UTC -5 Monthly albedo values Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. Albedo 0.79 0.77 0.57 0.28 0.20 0.20 0.20 0.20 0.20 0.20 0.41 0.67 Grid -Connected System PV Field Orientation Tracking plane, horizontal N -S axis Axis azimuth 0 System information PV Array Nb. of modules Pnom total System summary Tracking system with backtracking Near Shadings User's needs According to strings Unlimited load (grid) Electrical effect 100 % 18746 units 7498 kWp Inverters Nb. of units Pnom total Pnom ratio Results summary Produced Energy 10013 MWh/year Specific production 1335 kWh/kWp/year Perf. Ratio PR Table of contents Project and results summary General parameters, PV Array Characteristics, System losses Near shading definition - Iso -shadings diagram Main results Loss diagram Special graphs 40 units 5000 kWac 1.500 81.35% 2 3 6 7 8 9 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 2/9 Project: Norbut - Enfield Awl i��1 Variant: BV400_CPS125_SAT PVsyst V7.1.4 Namaste Solar (United States) VC3, Simulation date: 01/02/21 11:03 with v7.1.4 Project summary Geographical Site Situation Meteo data Enfield_SA34_GHIAvgmths Latitude 42.45 °N Enfield_SA34_GHIAvgmths United States Longitude -76.65 °W SA34: TGY - TMY Altitude 387 m Time zone UTC -5 Monthly albedo values Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. Albedo 0.79 0.77 0.57 0.28 0.20 0.20 0.20 0.20 0.20 0.20 0.41 0.67 Grid -Connected System PV Field Orientation Tracking plane, horizontal N -S axis Axis azimuth 0 System information PV Array Nb. of modules Pnom total System summary Tracking system with backtracking Near Shadings User's needs According to strings Unlimited load (grid) Electrical effect 100 % 18746 units 7498 kWp Inverters Nb. of units Pnom total Pnom ratio Results summary Produced Energy 10013 MWh/year Specific production 1335 kWh/kWp/year Perf. Ratio PR Table of contents Project and results summary General parameters, PV Array Characteristics, System losses Near shading definition - Iso -shadings diagram Main results Loss diagram Special graphs 40 units 5000 kWac 1.500 81.35% 2 3 6 7 8 9 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 2/9 Awl PVsyst V7.1.4 VC3, Simulation date: 01/02/21 11:03 with v7.1.4 Grid -Connected System PV Field Orientation Orientation Tracking plane, horizontal N -S axis Axis azimuth 0. Horizon Free Horizon Project: Norbut - Enfield Variant: BV400_CPS125_SAT Namaste Solar (United States) General parameters Tracking system with backtracking Backtracking strategy Nb. of trackers 56 units Sizes Tracker Spacing 5.03 m Collector width 2.03 m Ground Cov. Ratio (GCR) 40.3 % Backtracking limit angle SCA125KTL-DO/US-600 Phi limits +/- 66.1 ° Near Shadings (Custom parameters definition) According to strings Unit Nom. Power Electrical effect 100 % PV Array Characteristics Models used Transposition Diffuse Circumsolar User's needs Unlimited load (grid) Perez Imported separate PV module Inverter Manufacturer BOVIET Manufacturer Chint Power Systems Model BVM6612M-400L--H-HC Model CPS SCA125KTL-DO/US-600 (Custom parameters definition) 0.1% 0.2% 0.2% 0.2% (Custom parameters definition) 1.9% 5.4% Unit Nom. Power 400 Wp Unit Nom. Power 125 kWac Number of PV modules 18746 units Number of inverters 40 units Nominal (STC) 7498 kWp Total power 5000 kWac Modules 721 Strings x 26 In series Operating voltage 870-1300 V At operating cond. (50°C) Module Quality Loss Pnom ratio (DC:AC) 1.50 Pmpp 6808 kWp Loss Fraction 1.0 % at MPP U mpp 947 V I mpp 7189 A Total PV power Total inverter power Nominal (STC) 7498 kWp Total power 5000 kWac Total 18746 modules Nb. of inverters 40 units Module area 38131 m2 Pnom ratio 1.50 Cell area 34013 m2 Array losses Array Soiling Losses Average loss Fraction 2.3 % Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. 7.3% 6.3% 4.3% 1.1 % 0.1% 0.2% 0.2% 0.2% 0.2% 0.1% 1.9% 5.4% Thermal Loss factor DC wiring losses Serie Diode Loss Module temperature according to irradiance Global array res. 2.2 mQ Voltage drop 0.7 V Uc (const) 29.0 W/m2K Loss Fraction 1.5 % at STC Loss Fraction 0.1 % at STC Uv (wind) 0.0 W/m2K/m/s LID - Light Induced Degradation Module Quality Loss Module mismatch losses Loss Fraction 2.0% Loss Fraction -0.8 % Loss Fraction 1.0 % at MPP Strings Mismatch loss Loss Fraction 0.1 % 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 3/9 PVsyst V7.1.4 VC3, Simulation date: 01/02/21 11:03 with v7.1.4 Project: Norbut - Enfield Variant: BV400_CPS125_SAT Namaste Solar (United States) Array losses IAM loss factor Incidence effect (IAM): Fresnel AR coating, n(glass)=1.526, n(AR)=1.290 0° 30° 50° 60° 70° 75° 80° 85° 90° 1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 4/9 Awl PVsyst V7.1.4 VC3, Simulation date: 01/02/21 11:03 with v7.1.4 Project: Norbut - Enfield Variant: BV400_CPS125_SAT Namaste Solar (United States) AC wiring losses Inv. output line up to MV transfo Inverter voltage 600 Vac tri Loss Fraction 1.5 % at STC Inverter: CPS SCA125KTL-DO/US-600 Wire section (40 Inv.) Copper 40 x 3 x 70 mm2 Average wires length 110 m AC losses in transformers MV transfo Grid Voltage 20 kV Operating losses at STC Nominal power at STC (PNomac) 7337 kVA Iron loss (24/24 Connexion) 7.34 kW Loss Fraction 0.1 % at STC Coils equivalent resistance 3 x 0.49 mfg Loss Fraction 1.0 % at STC 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 5/9 Near shadings parameter Perspective of the PV -field and surrounding shading scene Iso -shadings diagram Norbut - Enfield 90 Beam shading factor (according to strings) : Iso -shadings curves -------- Shading loss: 1%' Attenuation for diffuse: 0.000 ---- Shading loss: 5% and albedo: 0.000 ---- Shading loss: 10% 75 ------ Shading loss: 20% 12h 6 s 4 s 1 3 II -enith South 1: 2L june 2: 22 may - 23 july 3: 20 apr - 23 aug 4: 20 mar - 23 seIT -Izu _W -60 -30 Azimgth [o] 30 120 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 6/9 Project: Norbut - Enfield Awls Variant: BV400_CPS125_SAT PVsyst V7.1.4 Namaste Solar (United States) VC3, Simulation date: 01/02/21 11:03 with v7.1.4 Near shadings parameter Perspective of the PV -field and surrounding shading scene Iso -shadings diagram Norbut - Enfield 90 Beam shading factor (according to strings) : Iso -shadings curves -------- Shading loss: 1%' Attenuation for diffuse: 0.000 ---- Shading loss: 5% and albedo: 0.000 ---- Shading loss: 10% 75 ------ Shading loss: 20% 12h 6 s 4 s 1 3 II -enith South 1: 2L june 2: 22 may - 23 july 3: 20 apr - 23 aug 4: 20 mar - 23 seIT -Izu _W -60 -30 Azimgth [o] 30 120 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 6/9 Awl PVsyst V7.1.4 VC3, Simulation date: 01/02/21 11:03 with v7.1.4 System Production Produced Energy Project: Norbut - Enfield Variant: BV400_CPS125_SAT Namaste Solar (United States) Main results 10013 MWh/year Specific production 1335 kWh/kWp/year Performance Ratio PR 81.35% Normalized productions (per installed kWp) Lc: Collection Loss (PV -array losses) 0.7 kWh/kWp/day Ls: System Loss (inverter, ...) 0.14 kWh/kWp/day a 8 Yf: Produced useful energy (inverter output) 3.66 kWh/kWp/day 3 3 6 4 z 2 0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Performance Ratio PR 1.2 - 1 1 1 1 1 1 1 1 1 1 1.1 - _ PR: Performance Ratio (Yf / Yr) : 0.813 = 1.0 0.9 = _ 0.8 y 0.7 0.6 0 0.5 0.4 0.3 0.2 0.1 0.0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Balances and main results 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 7/9 GlobHor DiffHor T_Amb Globinc GlobEff EArray E_Grid PR kWh/m2 kWh/m2 °C kWh/m2 kWh/m2 MWh MWh ratio January 46.1 29.21 -5.02 57.6 47.9 376 361 0.836 February 62.9 38.50 0.31 80.7 69.0 526 506 0.837 March 102.5 59.85 0.60 125.6 112.1 811 781 0.829 April 134.3 63.25 11.03 168.0 159.6 1028 989 0.785 May 169.3 77.12 16.64 210.1 203.1 1265 1219 0.774 June 174.9 74.98 18.62 218.6 211.6 1328 1279 0.780 July 180.6 80.63 19.51 225.4 218.2 1403 1352 0.800 August 158.8 76.44 19.34 198.3 191.4 1273 1227 0.825 September 119.8 53.25 15.56 155.1 149.5 1015 978 0.841 October 77.3 38.42 9.80 97.6 93.0 673 648 0.886 November 47.7 25.29 3.91 60.7 55.3 416 399 0.877 December 36.8 26.06 -2.51 43.8 37.0 286 274 0.833 Year 1310.9 643.00 9.02 1641.6 1547.9 10399 10013 0.813 Legends GlobHor Global horizontal irradiation EArray Effective energy at the output of the array DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid T_Amb Ambient Temperature PR Performance Ratio Globinc Global incident in coll. plane GlobEff Effective Global, corr. for IAM and shadings 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 7/9 Awl PVsyst V7.1.4 VC3, Simulation date: 01/02/21 11:03 with v7.1.4 1311 kWh/m2 Project: Norbut - Enfield Variant: BV400_CPS125_SAT Namaste Solar (United States) Loss diagram +25.2% -3.13% -1.38% -1.29% 1548 kWh/m2 ' 38131 m2 Coll. efficiency at STC = 19.69% Global horizontal irradiation Global incident in coil. plane Near Shadings: irradiance loss IAM factor on global Soiling loss factor Effective irradiation on collectors PV conversion 11619 MWh Array nominal energy (at STC effic.) -0.25% PV loss due to irradiance level -2.05% PV loss due to temperature 1-)0.00% Shadings: Electrical Loss acc. to strings +0.75% Module quality loss -2.00% LID - Light induced degradation -1.10% Mismatch loss, modules and strings -1.01% Ohmic wiring loss 10974 MWh Array virtual energy at MPP -1.74% Inverter Loss during operation (efficiency) -5.33% Inverter Loss over nominal inv. power '10.00% Inverter Loss due to max. input current '10.00% Inverter Loss over nominal inv. voltage y 0.00% Inverter Loss due to power threshold '10.00% Inverter Loss due to voltage threshold '10.00% Night consumption 10208 MWh Available Energy at Inverter Output 0.77% AC ohmic loss -1.15% Medium voltage transfo loss '10.00% MV line ohmic loss 10013 MWh Energy injected into grid 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 8/9 60000— ®� °® Q — 1i o ° � -.00 � ® ® ° ° R 50000— t OD o 3 ° ® o ° ° 419 a 40000 — ° o — ° @q48 P T° C 0 0 30000 — ° — c N G w 20000 — — 10000 — — I I I I 0 2 4 6 8 10 12 160000 140000 E 120000 ro s 3 100000 0 80000 E, r� 60000 40000 20000 Global incident in coll. plane [kWh/m2/day] System Output Power Distribution I I I I Values from 01/01 to 31/12 0 0 W9 ? V - - I -1a 11 - I I I 2000 3000 4000 Power injected into grid [kW] I 5000 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 9/9 Project: Norbut - Enfield Awl i��1 Variant: BV400_CPS125_SAT PVsyst V7.1.4 Namaste Solar (United States) VC3, Simulation date: 01/02/21 11:03 with v7.1.4 Special graphs Daily Input/Output diagram 70000 o Values from 01/01 to 31/12 60000— ®� °® Q — 1i o ° � -.00 � ® ® ° ° R 50000— t OD o 3 ° ® o ° ° 419 a 40000 — ° o — ° @q48 P T° C 0 0 30000 — ° — c N G w 20000 — — 10000 — — I I I I 0 2 4 6 8 10 12 160000 140000 E 120000 ro s 3 100000 0 80000 E, r� 60000 40000 20000 Global incident in coll. plane [kWh/m2/day] System Output Power Distribution I I I I Values from 01/01 to 31/12 0 0 W9 ? V - - I -1a 11 - I I I 2000 3000 4000 Power injected into grid [kW] I 5000 01/02/21 PVsyst Licensed to Namaste Solar (United States) Page 9/9