HomeMy WebLinkAboutNSF Enfield Sites, LLC - PVSyst Report 12-01-2020led 111 , vsl PH O TO V O LTA I C SO F T W A RE Version 7.1.0 PVsyst - Simulation report Grid -Connected System Project: Norbut - Enfield Variant: BV375 & BV400 CPS125 GM RBI 25 Unlimited sheds System power: 7463 kWp Enfield_SA34_GHIAvgmths - United States Author Namaste Solar (United States) 888 Federal Blvd Denver/80204 USA Project: Norbut - Enfield Awl Variant: BV375 & BV400_CPS125_GM RBI 25 PVsyst V7.1.0 Namaste Solar (United States) Simulation date: 01/12/20 13:39 with v7.1.0 Project summary Geographical Site Situation Meteo data Enfield_SA34_GHIAvgmths Latitude 42.45 °N Enfield_SA34_GHIAvgmths United States Longitude -76.65 °W SA34: TGY - TMY Altitude 387 m Time zone UTC -5 Monthly albedo values Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. Albedo 0.79 0.77 0.57 0.28 0.20 0.20 0.20 0.20 0.20 0.20 0.41 0.67 System summary Grid -Connected System Unlimited sheds PV Field Orientation Near Shadings User's needs Sheds Mutual shadings of sheds Unlimited load (grid) tilt 25 ° Electrical effect azimuth 0. System information PV Array Inverters Nb. of modules 18810 units Nb. of units 40 units Pnom total 7463 kWp Pnom total 5000 kWac Pnom ratio 1.493 Results summary Produced Energy 8941 MWh/year Specific production 1198 kWh/kWp/year Perf. Ratio PR 81.30% Table of contents Project and results summary 2 General parameters, PV Array Characteristics, System losses 3 Main results 5 Loss diagram 6 Special graphs 7 01/12/20 PVsyst Licensed to Namaste Solar (United States) Page 2/7 Project: Norbut - Enfield Awl Variant: BV375 & BV400_CPS125_GM RBI 25 PVsyst V7.1.0 Namaste Solar (United States) Simulation date: 01/12/20 13:39 with v7.1.0 PV Array Characteristics Array #1 - BV375 PV module Manufacturer General parameters Model BVM6612M-375-OPTIMIZED Grid -Connected System Unlimited sheds Unit Nom. Power 375 Wp PV Field Orientation 2430 units Nominal (STC) 911 kWp Orientation Sheds configuration At operating cond. (50'C) Models used Sheds Nb. of sheds 30 units Transposition tilt 25' Unlimited sheds 16380 units Diffuse azimuth 0. Sizes 6552 kWp Circumsolar 4375 kWac Sheds spacing 8.23 m Operating voltage 870-1300 V Collector width 4.05 m Pnom ratio (DC:AC) 1.50 Ground Cov. Ratio (GCR) 49.2 % Shading limit angle 947 V Limit profile angle 20.6 ° Shadings electrical effect Total inverter power Cell size 15.6 cm Total power 5000 kWac Strings in width 2 units Nb. of inverters Horizon Near Shadings 38034 m2 User's needs Free Horizon Mutual shadings of sheds 33901 m2 Unlimited load (grid) Electrical effect PV Array Characteristics Array #1 - BV375 PV module Manufacturer BOVIET Model BVM6612M-375-OPTIMIZED (Custom parameters definition) Model CPS Unit Nom. Power 375 Wp Number of PV modules 2430 units Nominal (STC) 911 kWp Modules 90 Strings x 27 In series At operating cond. (50'C) Operating voltage Pmpp 829 kWp U mpp 975 V I mpp 851 A Array #2 - BV400 Perez Imported separate Inverter Manufacturer Chint Power Systems Model CPS SCA125KTL-DO/US-600 (Custom parameters definition) Chint Power Systems Unit Nom. Power 125 kWac Number of inverters 5 units Total power 625 kWac Operating voltage 870-1300 V Pnom ratio (DC:AC) 1.46 PV module Inverter Manufacturer BOVIET Manufacturer Chint Power Systems Model BVM6612M-400L--H-HC Model CPS SCA125KTL-DO/US-600 (Custom parameters definition) (Custom parameters definition) Unit Nom. Power 400 Wp Unit Nom. Power 125 kWac Number of PV modules 16380 units Number of inverters 35 units Nominal (STC) 6552 kWp Total power 4375 kWac Modules 630 Strings x 26 In series Operating voltage 870-1300 V At operating cond. (50'C) Pnom ratio (DC:AC) 1.50 Pmpp 5949 kWp U mpp 947 V I mpp 6281 A Total PV power Total inverter power Nominal (STC) 7463 kWp Total power 5000 kWac Total 18810 modules Nb. of inverters 40 units Module area 38034 m2 Pnom ratio 1.49 Cell area 33901 m2 01/12/20 PVsyst Licensed to Namaste Solar (United States) Page 3/7 X006 Project: Norbut - Enfield Variant: BV375 & BV400_CPS125_GM RBI 25 PVsyst V7.1.0 Namaste Solar (United States) Simulation date: 01/12/20 13:39 with v7.1.0 Array losses Array Soiling Losses Average loss Fraction 6.2% Jan. Feb. Loss Fraction Mar. Apr. May June Average wires length July Aug. 20.4% 17.7% 12.0% 3.0% 0.1% 0.2% 0.2% 0.2% Thermal Loss factor Operating losses at STC Serie Diode Loss Nominal power at STC (PNomac) Module temperature according to irradiance Voltage drop 0.7 V Uc (const) 29.0 W/m2K Loss Fraction 0.1 % at STC Uv (wind) 0.0 W/m2K/m/s Module Quality Loss Module mismatch losses Loss Fraction -0.8% Loss Fraction 0.0 % at MPP IAM loss factor Incidence effect (IAM): Fresnel AR coating, n(glass)=1.526, n(AR)=1.290 0° 30° 50° 60° 70° 75° 1.000 0.999 0.987 0.962 0.892 0.816 Global wiring resistance 2.2 mfg Loss Fraction 1.5 % at STC Array #1 - BV375 Global array res. Loss Fraction Inv. output line up to MV transfo DC wiring losses Array #2 - BV400 19 mf) Global array res. 1.5 % at STC Loss Fraction AC wiring losses Inverter voltage 600 Vac tri Loss Fraction 0.2 % at STC Inverter: CPS SCA125KTL-DO/US-600 Wire section (40 Inv.) Copper 40 x 3 x 70 mm2 Average wires length 14 m AC losses in transformers MV transfo Grid Voltage 34.5 kV Operating losses at STC Nominal power at STC (PNomac) 7307 kVA Iron loss (24/24 Connexion) 7.38 kW Loss Fraction 0.1 % at STC Coils equivalent resistance 3 x 0.49 mf) Loss Fraction 1.0 % at STC Sep. Oct. Nov. Dec. 0.1% 5.1% 15.0% LID - Light Induced Degradation Loss Fraction 1.5 % 80° 85° 90° 0.681 0.440 0.000 2.5 mf) 1.5 % at STC 01/12/20 PVsyst Licensed to Namaste Solar (United States) Page 4/7 X006 Project: Norbut - Enfield Variant: BV375 & BV400_CPS125_GM RBI 25 PVsyst V7.1.0 Namaste Solar (United States) Simulation date: 01/12/20 13:39 with v7.1.0 Main results System Production Produced Energy 8941 MWh/year Specific production 1198 kWh/kWp/year Performance Ratio PR 81.30% Normalized productions (per installed kWp) I I I I I I I I I I I 7 -. Lc: Collection Loss (PV -array losses) 0.65 kWh/kWp/day - - Ls: System Loss (inverter, ...) 0.11 kWh/kWp/day T .0 6 _ Yf: Produced useful energy (inv :iter output) 3.28 kWh/kWp/day _ a 5 x 4 c w 3 2 0 z 1 0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Performance Ratio PR 1.2- 1.1 = _ PR. Performance Ratio (Yf / Yr) . 0.813 1-0 0.9 - - a 0-8 0-7 0.6 0.5 a 0-4 0.3 0.2 0.1 0-0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Balances and main results 01/12/20 PVsyst Licensed to Namaste Solar (United States) Page 5/7 GlobHor DiffHor T_Amb Globinc GlobEff EArray E_Grid PR kWh/m2 kWh/m2 °C kWh/m2 kWh/m2 MWh MWh ratio January 46.1 29.21 -5.02 65.7 48.7 378 364 0.742 February 62.9 38.50 0.31 82.9 64.0 489 473 0.764 March 102.5 59.85 0.60 121.0 100.6 734 711 0.787 April 134.3 63.25 11.03 147.2 136.6 900 873 0.794 May 169.3 77.12 16.64 171.6 164.5 1064 1032 0.806 June 174.9 74.98 18.62 172.3 164.9 1078 1047 0.814 July 180.6 80.63 19.51 182.4 174.8 1157 1123 0.825 August 158.8 76.44 19.34 170.6 163.8 1098 1066 0.837 September 119.8 53.25 15.56 139.4 133.8 904 877 0.843 October 77.3 38.42 9.80 99.7 95.7 664 643 0.864 November 47.7 25.29 3.91 69.8 62.6 460 443 0.851 December 36.8 26.06 -2.51 50.8 39.9 301 289 0.761 Year 1310.9 643.00 9.02 1473.4 1349.9 9227 8941 0.813 Legends GlobHor Global horizontal irradiation EArray Effective energy at the output of the array DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid T_Amb Ambient Temperature PR Performance Ratio Globinc Global incident in coil. plane GlobEff Effective Global, corr. for IAM and shadings 01/12/20 PVsyst Licensed to Namaste Solar (United States) Page 5/7 Awl PVsyst V7.1.0 Simulation date: 01/12/20 13:39 with v7.1.0 Project: Norbut - Enfield Variant: BV375 & BV400_CPS125_GM RBI 25 Namaste Solar (United States) 1350 kWh/m2 * 38034 m2 coil. efficiency at STC = 19.66% 10091 MWh 9687 MWh 9057 MWh 8941 MWh Loss diagram +12.4% -2.56% .2.07% 3.99% -0.61% -1.51% y -0.25% +0.75% %-1.50% 0.00% -0.94% 1.74% 4.83% '10.00% y 0.00% y -0.01 % '10.00% y 0.00% Global horizontal irradiation Global incident in coil. plane Near Shadings: irradiance loss IAM factor on global Soiling loss factor Effective irradiation on collectors PV conversion Array nominal energy (at STC effic.) PV loss due to irradiance level PV loss due to temperature Shadings: Electrical Loss , sheds2 strings in width Module quality loss LID - Light induced degradation Module array mismatch loss Ohmic wiring loss Array virtual energy at MPP Inverter Loss during operation (efficiency) Inverter Loss over nominal inv. power Inverter Loss due to max. input current Inverter Loss over nominal inv. voltage Inverter Loss due to power threshold Inverter Loss due to voltage threshold Night consumption Available Energy at Inverter Output y -0.09% AC ohmic loss -1.20% Medium voltage transfo loss y 0.00% MV line ohmic loss Energy injected into grid 01/12/20 PVsyst Licensed to Namaste Solar (United States) Page 6/7 Project: Norbut - Enfield Awl i��1 Variant: BV375 & BV400_CPS125_GM RBI 25 PVsyst V7.1.0 Namaste Solar (United States) Simulation date: 01/12/20 13:39 with v7.1.0 Special graphs Daily Input/Output diagram 50000 I I o Values from 01/01 to 31/12 -CP ° ° 8 °® 40000 — 0 0 ('0 — o °� v ®00�7� O 0 3 %® ®0 ° 30000 — 0 00000 — 000 o ° c o o Co v O O 20000 - �� ° - O �6 ®o W 0 e®° 10000 — °o — e - o - dOP 0 2 4 6 8 10 Global incident in coll. plane [kWh/m2/day] System Output Power Distribution 400000 — I I I — Values from 01/01 to 31/12 J 300000 — — c m s 3 - - 72 0 c 200000 — — �a U N T CA N C Lal 100000 0 I I 0 1000 2000 3000 4000 5000 Power injected into grid [kW] 01/12/20 PVsyst Licensed to Namaste Solar (United States) Page 7/7