Loading...
HomeMy WebLinkAboutDrawings RX X X X X X X X X Wilson LabBridge 4416 BRIDGECASCADILLA STEAM4403B BRIDGE CASCADILLACHILLED WATER4403A HUMPHREYS SERVICE BUILDING2023 CENTRAL HEATING PLANT5510B VEGETABLE CROPS BUILDING COMPLEX1087A,B,C WATERTREATMENTPLANT5510A CHILLED WATERPLANT III 5111 EAST ITHACA SHED 2080A EAST ITHACA ENV. HLTH.2080B 116MAPLE AV3010A MAPLE AVENUEPIPE/WELDING SHOP 2080C EAST ITHACA COMPLEX2080A,B TRANSPORTATIONSERVICES MACHINE SHOP2060 KITE HILLSUBSTATION 5325 WILSONSYNCHROTRONMODULE6095 WILSONSYNCHROTRONLNS TEMP SPACE 6040 120 MAPLE AV3010B 115 KV MAPLE AVESUB STATION CONTROL HOUSE5376A THERMALSTORAGETANK5111A FUELOILTANK5510E STEAMCONDENSERBUILDING5510F FUEL OILUNLOADING STATION5510G CCHPPLANT5510B CCHPOFFICEBUILDING5510B 115 KV MAPLE AVE TRANSFORMERS 5376 CHP5510B FE SHOPS ANNEX3016 WILSON WESTMODULAR UNIT6001E CITYWATERTANK CHPGASHOUSE5510J CORNELL PRINT SERVICES 2048 MAPLE AVE115KV SUBSTATION ANNEX5376CTOWN OF ITHACACI TY OF I THACAOH OHSTATE RTE 366MAPLE AVENUE NYS RT 366 ENERGY DRIVENYS RT 366 RAMP CBCBCBCBCBCB CB CBCBCBCBCBCBCB CB T-001 TITLE SHEET CIVIL C-101 PROPOSED LAYOUT PLAN C-102 DETAIL PLANS C-301 DETAILS C-302 DETAILS ELECTRIC E-001 GENERAL NOTES AND SYMBOL LEGENDS E-101 LOWER AND UPPER GATE ELECTRICAL PLANS E-102 FENCE GROUNDING AND BONDING PLAN E-401 DETAILS E-402 ACCESS CONTROL RISER DIAGRAMSCORNE LL U N I V E R SI TYFOUN D E D 5681 AD CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS T-001 11000237 TITLE SHEET FE DESIGN JG 5510B OCTOBER 12, 2018 CEP PHYSICAL SECURITY IMPROVEMENTS BUILDING CODE SUMMARY APPLICABLE CODES 2015 (EXISTING) IBC (ADOPTED BY NEW YORK STATE) PROJECT SUMMARY THIS PROJECT INCLUDES THE INSTALLATION OF SECURITY FENCING WITH GATES. PROJECT IMPROVEMENTS MEET CHAPTER 10 OF THE IBC. GENERAL SYMBOLS LEGEND EXTERIOR ELEVATION 1 1 1 1X-100 X-100 1 1 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE DRAWING REVISION NOTE# DRAWING INDEX LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN PROJECT SCOPE PROVIDE PHYSICAL SECURITY IMPROVEMENTS AND SIGNAGE TO PROHIBIT UNAUTHORIZED PERSONNEL FROM ENTERING CRITICAL AREAS OF THE CENTRAL HEATING PLANT.IMPROVEMENTS INCLUDE BUT ARE NOT NECESSARILY LIMITED TO: CHAIN LINK FENCING WITH BARBED WIRE; MANUAL, VEHICULAR AND PEDESTRIAN SWING GATES WITH LOCKS SIMILARLY KEYED; AUTOMATED CANTILEVER SLIDE GATES WITH CODE AND FIRE DEPARTMENT COMPLIANT ACCESS CONTROL; ASSOCIATED POWER, COMMUNICATIONS, AND GROUNDING; ROOF ENTRY PROTECTION; AND PERIMETER SIGNAGE. # # SITE LOCATION -CENTRAL ENERGY PLANT PROJECT AREA 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION X X X X X X X X X BRIDGE CASCADILLA STEAM 4403B BRIDGE CASCADILLA CHILLED WATER 4403A HUMPHREYS SERVICE BUILDING 2023 CENTRAL HEATING PLANT 5510B WATER TREATMENT PLANT 5510A CHILLED WATER PLANT III 5111 EAST ITHACA ENV. HLTH. 2080B MAPLE AVENUE PIPE/WELDING SHOP 2080C EAST ITHACA COMPLEX 115 KV MAPLE AVE SUB STATION CONTROL HOUSE 5376A THERMAL STORAGE TANK 5111A FUEL OIL TANK 5510E STEAM CONDENSER BUILDING 5510F FUEL OIL UNLOADING STATION 5510G CCHP PLANT 5510B CCHP OFFICE BUILDING 5510B 115 KV MAPLE AVE TRANSFORMERS 5376 CHP 5510B CHP GAS HOUSE 5510J MAPLE AVE 115KV SUBSTATION ANNEX 5376CTOWN OF ITHACACITY OF ITHACAENERGY DRIVENYS RT 366 CBCBCBCBCBCBCBCB CB 3 C-102 2 C-102 R O W R O W R O W 3 6 6 C L 12' DOUBLE SWING GATE 12' DOUBLE SWING GATE 12' DOUBLE SWING GATE 4 C-102 1 C-102 CHP ROOF ACCESS AT HUMPHREYS 4' WIDE PEDESTRIAN SWING GATE FOR CCHP ALLEY AMMONIA TANK 20' WIDE AUTOMATED SLIDING GATE 20' WIDE AUTOMATED SLIDING GATE PROVIDE 6' HIGH CHAIN LINK FENCE WITH BARBED WIRE (TYP.) SEE 1/C-301 PROVIDE 6' HIGH CHAIN LINK FENCE WITH BARBED WIRE (TYP.) PROVIDE 6' HIGH CHAIN LINK FENCE WITH BARBED WIRE (TYP.)ACCESS CONTROLED PEDESTRIAN GATE 20' PROVIDE NON-CONDUCTIVE BRIDGE FROM NEW FENCE TO EXISTING SUBSTATION FENCE 12' DOUBLE SWING GATE ACCESS CONTROLED PEDESTRIAN GATE PEDESTRIAN GATE 4 E-101 1 E-101 12' WIDE DOUBLE SWING GATE EXISTING GRADE 5' - 0" ABOVE GRADE 10" x 7" SIGN EMEDCO MODEL 43469 OR EQUAL NOTES: 1.0 ATTACH TO FENCE EVERY 100 FEET AND ON EACH GATE. 2.0 ATTACH TO FENCE USING FENCE MOUNTING BRACKET AND HARDWARE. DO NOT USE ZIP TIES.CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS C-101 11000237 PROPOSED LAYOUT PLAN J. TOFTE JG 5510B OCTOBER 12, 2018 0'20' 40' 80' SCALE: 1"=40'-0" SCALE: 1" = 40'-0"1 PROPOSED LAYOUT PLAN GENERAL NOTES 1.0 ALL MANUAL SWING GATES WILL BE IDENTICALLY KEYED AS DIRECTED BY CORNELL. 2.0 KNOX BOX TO BE PROVIDED FOR SLIDE GATE ACCESS CONTROL AND PHYSICAL KEY FOR CU SWING GATES (BY OTHERS). 3.0 CONTRACTOR SHALL PROVIDE STAKEOUT OF FENCING BY USE OF AUTOCAD (.DWG) FILES PROVIDED BY CORNELL. 4.0 INSTALL "NO TRESPASSING" SIGNAGE EVERY 100 FEET ALONG FENCE PERIMETER AND AT EACH GATE. SEE 2/C101. SCALE:NO SCALE2NO TRESPASSING SIGNAGE FENCING COMPONENTS ESTIMATED QUANTITIES* ITEM QUANTITY 6' HIGH CHAIN LINK FENCE WITH BARBED WIRE 1800 LF 4' WIDE ACCESS CONTROLLED PEDESTRIAN GATES 2 EACH 12' WIDE DOUBLE SWING GATES 5 EACH 20' WIDE AUTOMATED SLIDE GATE 2 EACH 4' MANUAL SWING GATE 2 EACH ROOF ACCESS GATE 1 EACH NON-CONDUCTIVE BRIDGE LOCATIONS 2 EACH BARBED WIRE ATTACHED TO EXISTING FENCE 30 LF * ESTIMATED QUANTITIES ARE PROVIDED FOR SELECT MAJOR ITEMS AND ARE NOT NECESSARILY INCLUSIVE OF ALL REQUIRED WORK. ESTIMATED QUANTITIES SHALL SERVE AS THE BASE FOR CHANGES IN QUANTITIES. FENCING SCOPE OF WORK 1.0 PROVIDE 6' HIGH CHAINLINK FENCE WITH BARBED WIRE TO SECURE INTENDED AREAS AS SHOWN. 2.0 PROVIDE PEDESTRIAN AND VEHICULAR ACCESS GATES AS SHOWN, INCLUDING ALL ASSOCIATED AUTOMATION EQUIPMENT, LOCKING MECHANISMS AND ACCESS CONTROLS AS INDICATED. 3.0 PROVIDE ALL ASSOCIATED DEMOLITION, EARTWORK, AND RESTORATION REQUIRED TO COMPLETE THE PROJECT. 4.0 PROVIDE ALL REQUIRED SAFETY SIGNAGE REQUIRED FOR GATES AND NO TRESPASS SIGNAGE AS INDICATED. 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION MAPLE AVENUE PIPE/WELDING SHOP 2080C CB4' WIDE SWING GATE WITH LOCK 6' HIGH CHAIN LINK FENCE WITH BARBED WIRE 4' HIGH CHAIN LINK FENCE 3' WIDE SWING GATE HUMPHREYS SERVICE BUILDING HUMPHREYS SERVICE BUILDING 6' x 12' FREE EXIT LOOP CANTILEVER SLIDE GATE SEE DETAIL 5/C-301 GATE OPERATOR ACCESS CONTROL STATION WITH BOLLARD PROTECTION 20' 6' x 12' SAFETY LOOP CARD ACCESS READER (BY OTHERS) 4' PEDESTRIAN GATEFIRE DEPARTMENT KNOX BOX (BY OTHERS) 6' X 12' FREE EXIT LOOP CANTILEVER SLIDE GATE SEE DETAIL 5/C-301 12' DOUBLE SWING GATE WITH LOCK FIRE DEPARTMENT KNOX BOX (BY OTHERS) ACCESS CONTROL PAD CARD READER / KEY PAD GATE OPERATOR 6' X 12' SAFETY LOOP 20'4' PEDESTRIAN GATE 16' CARD ACCESS READER (BY OTHERS) BOLLARD 12' DOUBLE SWING GATE 4' PEDESTRIAN GATE CONNECT TO EXISTING CHAIN LINK FENCE 4' MIN. EXISTING ASPHALT BERM MODIFY EXISTING FENCE TO INSTALL BARBED WIRE TOP CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS C-102 11000237 DETAIL PLANS J. TOFTE JG 5510B OCTOBER 12, 2018 SCALE: 1" = 10'-0"1 OUTER AREAS PROTECTION PLAN SCALE: 1" = 20'-0"2 UPPER GATE DETAIL SCALE: 1" = 20'-0"3 LOWER GATE DETAIL SCALE: 1" = 20'-0"4 AMMONIA TANK PROTECTION PLAN PROVIDE LOCKABLE 3' WIDE SWING GATE PROVIDE 4' HIGH CHAIN LINK FENCE MOUNTED TO FACADE WITH SIGNAGE 0' 20' 40' SCALE: 1"=20'-0" 10'5' 0' 10' 20' SCALE: 1"=10'-0" 5' 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION NOTES:(MIN.)2"(MIN.)1'-0"2"1'-0" BRACE BAND W/CARRIAGE BOLT 9 GAGE ALUMINUM TIE-WIRE SPACED 1'-2" O.C. ON LINE POSTS 9 GAGE ALUMINUM TIE-WIRE SPACED 2'-0" O.C. 2" MAX. 4' -0"4' -0" 1/4"x3/4" TENSION BAR 7' - 6" 1 5/8" O.D., SCH. 40 TOP & BRACE RAIL TERMINAL POST CAP CHAIN LINK FABRIC 2" MESH, 9 GAUGE RAIL END TENSION ROD BOTTOM SELVAGE KNUCKLED 3" O.D., SCH. 40 TERMINAL OR CORNER POST 1"x12 GAUGE TENSION BAND WITH CARRIAGE BOLT (USE ONE LESS THAN HEIGHT OF FABRIC IN FEET) 1.0 ALL COMPONENTS SHALL BE VINYL COATED BLACK. 2.0 FENCE TO HAVE TOP TENSION WIRE AND BOTTOM TENSION WIRE OF NO. 7 GAGE ALUMINIZED STEEL, SECURED TO FABRIC WITH ALUMINUM HOG RINGS 2'-0" O.C. AS SHOWN. 3.0 ALL FITTINGS TO BE IN ACCORDANCE WITH ASTM F626. 4.0 INSTALLATION OF FENCE TO BE IN ACCORDANCE WITH ASTM F567. 5.0 SUBMIT SHOP DRAWINGS FOR APPROVAL. 3 STRANDS BARBED WIRE BRACE END WITH 3/8" TRUSS ROD FINISHED GRADE SLOPE FOR DRAINAGE CONCRETE, 4000 PSI COMPRESSIVE STRENGTH 10' - 0" O.C. MAX. (TYP.) TOP FRAME NOTES: 2" O.D., SCH. 40 PIPE FOR GATE PERIMETER FRAMING 2" MIN. CLEAR. FINISHED GRADE 1 5/8" O.D., SCH. 40 PIPE FOR GATE INTERIOR FRAMING ALL JOINTS TO BE WELDED & HOT DIPPED GALVANIZED AFTER FABRICATION SLOPE FOR DRAINAGE MALLEABLE IRON FORK TYPE LATCH W/DROP BAR & PROVISION FOR PADLOCK MALLEABLE IRON 180° OFFSET INDUSTRIAL TYPE HINGE CONCRETE, 4000 PSI MINIMUM COMPRESSIVE STRENGTH 4" O.D. SCH. 40 GATE POST 1.0 ALL COMPONENTS SHALL BE VINYL COATED BLACK. 2.0 MISCELLANEOUS HARDWARE SIMILAR TO THAT USED IN LINE OF FENCE. 3.0 PROVIDE MECHANICAL KEEPER AT FULL OPEN POSITION FOR EACH LEAF OF 12' GATE 4.0 SUBMIT SHOP DRAWINGS FOR APPROVAL. (GATE OPENING) BARBED WIRE TO MATCH THAT USED IN LINE OF FENCE FABRIC TO MATCH THAT USED IN LINE OF FENCE 12' - 0" 6' - 0" 1' - 6" 4' - 0" 2" (MIN.) 3 1/2" 3' - 0" 1 1/2" (TYP.) 1' - 0" 1' - 0" 2' - 0" DESCRIPTION CRITICAL DIMENSION CHART CLEAR OPENING POST HEIGHT (W BARB ARMS) FABRIC HEIGHT COUNTERBALANCE LENGTH OVERALL GATE LENGTH NOMINAL GATE HEIGHT F G MARK C E D A B 7' -6"E + 1' -6" 5' -0"E -1' -0" DIM. 20' -0" 30' -0" 6' -0" 10' -0" 9' -1" FORMULA (A/2)-11" A x 1.5 E A x 0.5 A COUNTERBALANCE POST SPACING C/C LENGTH CATCH ASSEMBLY BOTTOM GUIDE ELEVATION PLAN VIEW ENLARGED SECTION SECTION SECTION VIEW 4" O.D. POSTCOMPANION CATCHER BOTTOM GUIDE BRACKET 4" O.D. POST GUIDE WHEEL GRADE TRACK TRACK FABRIC NOTES: 1.0 ALL FITTINGS STANDARDLY PROVIDED FOR 4" O.D. POSTS. OTHER SIZES AVAILABLE UPON REQUEST. 2.0 INCLUDE BARBED WIRE TO MATCH 6/C-301. 3.0 GATE SHALL BE COMPLIANT WITH ASTM F2200, CLASS IV. DETAIL 7 DETAIL 8 SEE DETAIL 8 SEE DETAIL 7SEE DETAIL 9 BARBED WIRE SEE DETAIL 9 SEE DETAIL 8 (BELOW 7)SEE DETAIL 7 SEE DETAIL 8 (BELOW 7)SEE DETAIL 7 UL 325 COMPLIANT WHEEL COVERS (STANDARD) SMOOTH LEADING EDGE. (NO PROTRUSIONS PER ASTM F 2200) HANGER BRACKET 5/8" HANGER BOLT GUSSETS W4 TRUCK SPHERICAL SUPPORT BEARINGS ASTM F 2200 COMPLIANT GAP PROTECTORS (STANDARD) SEE DETAIL 7 W4 TRUCK (TYP) 4' - 0" MINIMUM 5"SEE DETAIL 8 GATE HANGER ASSEMBLY A = CLEAR OPENING B = POST SPACING C/C C = OVERALL GATE LENGTH D = COUNTERBALANCE G 5" E F GRADE INSTALL 6" DIAMETER "IDEAL SHIELD" OVER ALL BOLLARDS, BLACK UNLESS OTHERWISE SPECIFIED. AVAILABLE AT (313) 842-7290 OR WWW.IDEALSHIELD.COM 6 5/8" O.D. STEEL PIPE BOLLARD FILLED WITH CONCRETE SLOPE CONCRETE SEAL JOINT WITH RUBBERIZED ASPHALT CRACK FILLER OR POLYURETHANE CAULK, FLUSH WITH ADJACENT PAVEMENT ISOLATION JOINT AIR ENTRAINED CONCRETE BASE 1' - 6" 3' - 0" 3' - 0" 6" LAWN SEED OR HYDROSEED -AS SPECIFIED. STRAW MULCH -STALKS FROM OATS, WHEAT AND/OR RYE FREE FROM SEED AND WEED SEED NO NON-BIODEGRADABLE (PLASTIC, NYLON, ETC.) EROSION CONTROL NETTING OR MATTING PERMITTED. EXISTING LAWN TOPSOIL MIX AS SPECIFIED -4" AFTER SETTLEMENT UNDISTURBED AND/OR COMPACTED EARTH BACK FILL AS SPECIFIED -2/3 EXISTING SOIL MIXED WITH 1/3 NEW ORGANIC MATERIAL NOTE: FERTILIZE AS SPECIFIED 4" MIN 4" MIN UNDISTURBED SOIL TRACEABLE ELECTRIC WARNING TAPE, 12" BELOW GRADE ROADWAYS -REPLACE TO MATCH EXISTING CONDITIONS. LAWNS -BACKFILL COMPACTED IN 12" LAYERS ROADWAYS -NYS DOT 304-2.02 TYPE 2 SUBBASE COMPACTED IN 6" LAYERS SAND ENCASEMENT OR SELECT BACKFILL (NO ROCKS BIGGER THAN 1") -COMPACTED IN 6" LAYERS GRASS-RESEED PER CORNELL LAWN AREA SEEDING DETAIL FINISHED GRADE TOPSOIL MIX -6" MINIMUM COMPACTED DEPTH SCH 80 PVC DUCTS (PVC JOINTS TO BE CLEANED AND GLUED) NOTES: 1.0 DIRECT BURIED CABLES NOT ALLOWED. 2.0 SEAL DUCTS AT END OF DAY DURING CONSTRUCTION. 3.0 CONTRACTOR TO CONTACT CORNELL FACILITIES ENGINEERING TO GPS AND PHOTOGRAPH LOCATION PRIOR TO BACKFILLING TRENCH. 4.0 PULL MANDREL THROUGH WITH REPRESENTATIVES OF CORNELL UTILITIES TO WITNESS. 12" 6" BED 6" COVER 2' - 0" INSTALL 6" DIAMETER "IDEAL SHIELD" OVER ALL BOLLARDS. AVAILABLE AT (313) 842-7290 OR WWW.IDEALSHIELD.COM 6 5/8" O.D. STEEL PIPE BOLLARD FILLED WITH CONCRETE SLOPE CONCRETE 4000 p.s.i. CONCRETE 3' - 0" 3' - 0" 6" 1' - 6"CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS C-301 11000237 DETAILS J. TOFTE JG 5510B OCTOBER 12, 2018 SCALE: NO SCALE 6 CHAIN LINK FENCE DETAIL SCALE: NO SCALE 7 DOUBLE SWING GATE DETAIL SCALE: NO SCALE 5 HEAVY DUTY CANTILEVER SLIDE GATE SCALE: NO SCALE 2 BOLLARD IN PAVEMENT DETAIL SCALE: NO SCALE 4 LAWN AREA-SEEDING DETAIL SCALE: NO SCALE 3 DIRECT BURIED CONDUIT DETAIL SCALE: NO SCALE 1 BOLLARD IN GRASS PANEL DETAIL NOTE: MAINTAIN MINIMUM 12" SEPARATION BETWEEN POWER AND GATE OPERATOR CONTROL RACEWAYS. 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION 36" 6" ASPHALT PAVEMENT CONCRETE FOUNDATION AS PER MANUFACTURERS RECOMMENDATION (2) 3/4 INCH ELECTRICAL CONDUITS ASPHALT PAVEMENT BASE COVER 48"SPACER TYPE A LED LUMINAIRE CARD READER (BY OTHERS) PEDESTAL SIMILAR TO: DOORKING DESIGNER OFFSET WITH OPTIONAL LIGHT TOWER NOTES: 1.0 THE OPENING IN THE FENCE LINE SHALL BE BUILT TO ACCOMMODATE THE DOOR JAMB PER THE OWNERS SPECIFICATIONS. 2.0 GATE FRAME WILL BE FILLED WITH 1/2" x 3" x 8 GA. WELDED WIRE MESH OR AS SPECIFIED. 3.0 PANIC BAR (BY OTHERS). 4.0 ELECTRIC STRIKE (BY OTHERS). 5.0 * CLEAR OPENING SIZES: 4'-0". 6.0 CONTRACTOR MAY PROVIDE ALTERNATE PEDESTRIAN GATE. HOWEVER, GATE SHALL BE CONSTRUCTED TO FUNCTION WITH ACCESS CONTROL COMPONENTS INCLUDING PANIC BAR AND ELECTRIC STRIKE LOCKING MECHANISM. TYMETAL HEAVY DUTY HINGE (2 TYP.) DOOR JAMB (4" x 4"STEEL TUBE) PROVIDE 1/4"STEEL PLATE (BEHIND) DOOR FRAME (2" x 2" STEEL TUBE) FILLER FABRIC CLOSER AND DOOR POSITION SWITCH (BY OTHERS) 4' - 4" 1' - 3"1' - 3" 3' - 6" *SEE NOTE 5 6' - 0" 4' - 0" 3' - 6" 6" 6' - 0" AS PER GATE MANUFACTURERS RECOMMENDATION. AT MINIMUM, DOOR FRAME FOUNDATIONS SHALL MATCH TYPICAL POST FOUNDATIONS. BARBED WIRE (TYP.) EXTERIOR RATED PANIC BAR (BY OTHERS) LOCKING MECHANISM (BY OTHERS) PROVIDE TYMETAL PEDESTRIAN GATE OR EQUIVALENT FINISHED GRADE 8' - 0" NON-CONDUCTIVE FENCE FABRIC FASTEN BY CONVENTIONAL MEANS (TYP.) PRESSURE TREATED WOOD SUPPORT EXISTING SUB-STATION FENCING NOTE: NON-CONDUCTIVE MATERIAL SHALL BE USED TO CREATE A MINIMUM EIGHT (8) FOOT BRIDGE BETWEEN NEW FENCE AND EXISTING SUBSTATION FENCING COMPONENTS. TYPE 4 SUBBASE, NYSDOT ITEM #304.14 OR APPROVED ASPHALT MILLINGS MAY BE USED IN BOTTOM LIFT AND SHALL NOT EXCEED 3" IN THICKNESS NOTE: ALL SUBGRADE MATERIALS ARE EXISTING AND SHOWN FOR REFERENCE ONLY 4.5" COMPACTED NYSDOT SUPERPAVE 19MM BINDER (402.197903)* FILTER FABRIC MIRAFI 500X OR EQUIVALENT COMPACTED SUBGRADE 1 1/2" COMPACTED NYSDOT SUPERPAVE 9.5MM TOP COURSE (402.097203)* 15" COMPACTED TYPE 2 SUBBASE, NYSDOT ITEM #304.12 (LEDGEROCK) 15" 3"CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS C-302 11000237 DETAILS J. TOFTE JG 5510B OCTOBER 12, 2018 SCALE: NO SCALE 1 ACCESS CONTROL STATION SCALE: NO SCALE 2 PEDESTRIAN GATE W/ PANIC BAR SCALE: NO SCALE 3 NON-CONDUCTIVE BRIDGE DETAIL SCALE: NO SCALE 4 HEAVY DUTY ASPHALT PAVEMENT RESTORATION DETAIL 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS E-001 11000237 GENERAL NOTES AND SYMBOL LEGENDS C. WAYMAN CMW 5510A, 5510B OCTOBER 12, 2018 GENERAL ELECTRICAL NOTES 1.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS ARE DIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORK PROCEEDS. 2.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND OPERABLE. 3.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED. 4.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF WORK. 5.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS. 6.0 CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRAL CONDUCTORS. 7.0 CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90 DEGREE C, TYPE THHN/THWN-2 FOR DRY AREAS AND XHHW/THWN-2 FOR WET AREAS. 8.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTED OTHERWISE. 9.0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE PANELBOARD. SIZE AS INDICATED. 10.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT HANGERS FOR CONDUIT AS NEEDED. 11.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT AND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. ELECTRICAL SCOPE OF WORK 1.0 PROVIDE ALL ELECTRICAL WORK ASSOCIATED WITH THE INSTALLATION OF EACH SLIDING GATE. 2.0 PROVIDE ALL RACEWAYS AND SECURITY WIRING ASSOCIATED WITH THE CARD ACCESS SYSTEM. 3.0 ALL ACCESS CONTROL EQUIPMENT (DOOR CONTROLLERS, ENCLOSURES, AND CARD READERS) BY OTHERS. 4.0 PROVIDE ALL TRENCHING, BACKFILL, AND SITE RESTORATION REQUIRED TO INSTALL POWER AND ACCESS CONTROL TO EACH SLIDING GATE AND PEDESTRIAN GATE. 5.0 ACCESS CONTROL SYSTEM PROGRAMMING AND COMMISSIONING BY OTHERS. 6.0 PROVIDE ALL NECESSARY GATE OPERATOR SYSTEM PROGRAMMING AND COMMISSIONING. 7.0 PROVIDE ALL FENCE GROUNDING AS SHOWN. 8.0 PROVIDE EXIT DISCHARGE EGRESS LIGHTING, INCLUDING ALL BRANCH CIRCUIT WIRING. 9.0 PROVIDE PEDESTAL MOUNTED LUMINAIRES AT SLIDING GATE CARD READERS. ELECTRICAL LEGEND LIGHTING LEGEND MOTOR 1'x4' LUMINAIRE GROUND/BOND CONNECTION P-1A12 HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT. PHOTOEYE SENSOR GROUND ROD ELECTRODE DUPLEX RECEPTACLE WITH GFCI PROTECTION DUPLEX RECEPTACLE WITH AFCI PROTECTION QUAD RECEPTACLE LINETYPES LEGEND SPECIAL RECEPTACLE5-30R PE PANELBOARD JUNCTION BOX B = INSTALLED IN BASEBOARD TR = INSTALLED IN WOOD TRIM/CASEWORK/WAINSCOTT SR = SURFACE RACEWAY WP = WEATHERPROOF AC = AIR CONDITIONER DUPLEX RECEPTACLE: DOUBLE DUPLEX RECEPTACLE MOTOR STARTER J 2'x4' LUMINAIRE CEILING MOUNTED LUMINAIRE EM LIGHTING BATTERY UNIT COMBO EXIT SIGN/EM LIGHTING BATTERY UNIT SINGLE FACE, WALL MOUNT EXIT SIGN DOUBLE FACE, WALL MOUNT EXIT SIGN SINGLE FACE, CEILING MOUNT EXIT SIGN DOUBLE FACE, CEILING MOUNT EXIT SIGN LIGHT SWITCH: SAFETY SWITCH (NON-FUSED) SAFETY SWITCH (FUSED) X 3 = 3-WAY SWITCH 4 = 4-WAY SWITCH D = DIMMER SWITCH O = WALL SWITCH OCCUPANCY SENSOR V = WALL SWITCH VACANCY SENSOR W = WIRELESS SWITCH S = WIRELESS SCENE SWITCH WIRELESS OCCUPANCY SENSOR WIRELESS DAYLIGHT SENSOR OS W DS 1'x2' LUMINAIRE SECURITY LEGEND CARD READER LOCKING MECHANISM KNOX BOX DOOR POSITION CONTACTS ELECTRICAL ABBREVIATIONS AC AIR CONDITIONER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFI ARC FAULT INTERRUPTER AMM ADDRESSABLE MONITOR MODULE AOM ADDRESSABLE OUTPUT MODULE ARB AUXILIARY RELAY BOARD ATS AUTOMATIC TRANSFER SWITCH B BASEBOARD BKR BREAKER C CONDUIT CD CANDELA CKT CIRCUIT CR CONTROL RELAY EC ELECTRICAL CONTRACTOR EMT ELECTRICAL METALLIC TUBING EPO EMERGENCY POWER OFF STATION FAA FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FSD FIRE SMOKE DAMPER GAA GENERATOR ALARM ANNUNCIATOR GFI GROUND FAULT INTERRUPTER GND GROUND HP HORSEPOWER KW KILOWATT LC LIGHTING CONTACTOR LFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUIT LTG LIGHTING MCB MAIN CIRCUIT BREAKER MLO MAIN LUG ONLY MTS MANUAL TRANSFER SWITCH NAC NOTIFICATION APPLIANCE CIRCUIT NIC NOT IN CONTRACT OE OVERHEAD ELECTRIC PC PHOTOCELL PM PLUGMOLD PP POWER PANEL PVC POLYVINYL CHLORIDE CONDUIT RGS RIGID GALVANIZED STEEL CONDUIT SR SURFACE RACEWAY ST SHUNT TRIP TM THERMAL MAGNETIC TR TRIM/CASEWORK/WAINSCOTT TSP TWISTED SHIELDED PAIR TYP TYPICAL UE UNDERGROUND ELECTRIC UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS VA VOLT AMPS WP WATERPROOF UNDERGROUND ELECTRICUE UNDERGROUND LIGHTINGUL OVERHEAD ELECTRICOE TO BE PROVIDED DEMOLITION / TO BE RELOCATED EXISTING TO REMAIN UNDERGROUND TELCOUC MOUNTING HEIGHTS CARD READER 48" TOP OF BOX LIGHT SWITCH 48" TOP OF BOX RECEPTACLE 18" TOP OF BOX DATA OUTLET 18" TOP OF BOX TV OUTLET 84" TOP OF BOX PHONE OUTLET 48" TOP OF BOX SAFETY SWITCH 60" CENTERLINE OF HANDLE MOTOR STARTER 60" CENTERLINE OF HANDLE PANELBOARD 72" TOP OF PANELBOARD MANUAL PULL STATION 48" OPERABLE HANDLE NOTIFICATION APPLIANCE 80" BOTTOM OF LENS DOOR HOLD OPEN COORDINATE IN FIELD EM BATTERY UNIT 96" BOTTOM OF UNIT EM REMOTE UNIT 102" BOTTOM OF UNIT EXIT SIGN 96" BOTTOM OF UNIT LIGHT POLE WITH LED LUMINAIRES, REFER TO PLANS FOR NUMBER AND CONFIGURATION OF HEADS GENERAL ELECTRICAL DEMOLITION NOTES 1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDING ASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHER APPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED. REMOVE ASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTED OTHERWISE. 2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEW WORK SHALL BE REUSED WHERE POSSIBLE. 3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTING SYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWN TO BE DEMOLISHED. 4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITH THE SURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRE RATED SURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCH SURROUNDING MATERIALS, FINISHES, AND COLORS. 5.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURING CONSTRUCTION. LUMINAIRE SCHEDULE TYPE DESCRIPTION MOUNTING SIZE MANUFACTURER CATALOG NO. VOLTAGE WATTAGE FINISH A LED WALLPACK W/ EM BATTERY SURFACE 17"x6" HE WILLIAMS VWPH-L30-TFT-DBZ-CGL-PC-EM/10WC-UNV 120-277 36 D. BRONZE B MINI LED WALLPACK SURFACE 7"x7" HE WILLIAMS WPM-L8/750-PC-UNV 120-277 11 D. BRONZE KB C L CR FENCE CONDUIT ROUTING NOTES 1.0 INSTALL RACEWAYS ON VERTICAL FENCE POSTS AND HORIZONTAL FENCE TOP RAILS. DO NOT INSTALL OR FASTEN RACEWAYS TO FENCE FABRIC. 2.0 INSTALL RACEWAYS PARALLEL WITH AND PERPENDICULAR TO POSTS AND RAILS. 3.0 SECURELY FASTEN RACEWAYS TO POSTS AND RAILS WITH STAINLESS STEEL CLAMPS AND HARDWARE. 4.0 EXPOSED RACEWAYS SHALL BE GALVANIZED RMC. PROVIDE GALVANIZED RMC CONDUIT SWEEPS. 5.0 SUPPORT MULTIPLE RACEWAYS TO FENCE STRUCTURE WITH GALVANIZED METAL STRUT. SECURE STRUT TO POSTS AND RAILS WITH STAINLESS STEEL CLAMPS AND HARDWARE. 6.0 PROVIDE DIE-CAST ALUMINUM, POWDER COATED JUNCTION BOXES AND CONDUIT BODIES, RATED NEMA 3R WITH GASKETED COVERS AND STAINLESS STEEL HARDWARE. 7.0 SECURELY FASTEN ALL BOXES AND CONDUIT BODIES TO POSTS AND RAILS WITH GALVANIZED METAL STRUT. SECURE STRUT TO POSTS AND RAILS WITH STAINLESS STEEL CLAMPS AND HARDWARE. 8.0 PROVIDE LIQUIDTIGHT METALLIC CONDUIT AT CONNECTIONS TO SWING AND SLIDE GATES. 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION UP DN DN 303 301B 301A 301 306 302 300JA 300TB 300TA300CJ310 300CK DN BENCH BENCH UP WATER TREATMENT PLANT 5510A CHILLED WATER PLANT 3 5111 SEE #2/E-101 FOR CONTINUATION 3 4 5 6 7 CARD READER WITH PEDESTAL AND LUMINAIRE GATE OPERATORUE UC EXIT LOOP7SAFETY LOOP 11 CARD READER MOUNTED TO FENCE POST UNDERGROUND GATE OPERATOR AND PEDESTAL LUMINAIRE POWER 4 UNDERGROUND ACCESS CONTROL AND GATE CONTROLS 13EXIT DISCHARGE LUMINAIRE 14ACCESS CONTROL HANDHOLE 14 GATE OPERATOR AND PEDESTAL LUMINAIRE POWER HANDHOLEUC 15 PEDESTAL MOUNTED LUMINAIRE 16KNOX BOX PEDESTRIAN GATE A C LCR CR KB 1 EXISTING PANEL WTP-LP-1 1" EMT DOWN TO BASEMENT (#3/E-101 FOR CONTINUATION) 1" EMT ABOVE OVERHEAD DOOR (ACCESS CONTROL) 1" EMT ABOVE MEZZANINE CEILING IS 22'-6" ON THIS LEVEL SEE #1/E101 FOR CONTINUATION 2 10 EXISTING PANEL LP-1 9 LP-1-1 LP-1-3 LP-1-1 LP-1-3 LP-1-3 LP-1-1 TYP 8 EXISTING LENEL ACCESS CONTROL PANEL SEE #4/E-101 FOR CONTINUATION 3/4" EMT (GATE OPERATOR POWER) 1" EMT (ACCESS CONTROL) 12 CARD ACCESS CONTROL PANEL AND POWER SUPPLY PROVIDE FIRE-RATED PENETRATION CCHPP 5510B 5 6 CARD READER WITH PEDESTAL AND LUMINAIRE GATE OPERATOR SEE #5/E-101 FOR CONTINUATION 3 UCUE4 UNDERGROUND GATE OPERATOR AND PEDESTAL LUMINAIRE POWER 11 CARD READER MOUNTED TO FENCE POST UC7SAFETY LOOP 14ACCESS CONTROL HANDHOLE 4 UNDERGROUND ACCESS CONTROL AND GATE CONTROLS 7 EXIT LOOP 14 GATE OPERATOR AND PEDESTAL LUMINAIRE POWER HANDHOLE 15 PEDESTAL MOUNTED LUMINAIRE PEDESTRIAN GATE C L C R C R K B 16KNOX BOX 1" EMT UP TO FIRST FLOOR (#2/E-101 FOR CONTINUATION) 1" EMT (ACCESS CONTROL) CLAMPED TO CEILING CEILING IS 9'-0" ON THIS LEVEL 8 CARD ACCESS CONTROL PANEL AND POWER SUPPLY EXISTING JBOX WITH CARD ACCESS CIRCUITRY FROM THE CCHPP EXISTING LENEL AND STANLEY CARD ACCESS EQUIPMENT CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS E-101 11000237 LOWER AND UPPER GATE ELECTRICAL PLANS C. WAYMAN CMW 5510A, 5510B OCTOBER 12, 2018 SCALE: 1/16" = 1'-0"1 LOWER GATE - ELECTRICAL PLAN SCALE: 1/8" = 1'-0"2 WATER TREATMENT PLANT - FIRST FLOOR ELECTRICAL PLAN SCALE: 1/8" = 1'-0"5 CCHPP - THIRD FLOOR ELECTRICAL PLAN SCALE: 1/16" = 1'-0"4 UPPER GATE - ELECTRICAL PLAN E-101 CONSTRUCTION KEY NOTES 1 PROVIDE 2#12, 1#12G, 3/4" EMT FROM SPARE 20/1 CIRCUIT BREAKER #8 FOR LOWER GATE OPERATOR. MODIFY PANELBOARD DIRECTORY ACCORDINGLY. 2 PROVIDE (2) 1" COREDRILLS THRU BRICK/CMU WALL FOR LOWER GATE OPERATOR POWER AND ACCESS CONTROL RACEWAYS. PATCH OPENINGS WITH GROUT AFTER RACEWAY INSTALLATION AND PAINT TO MATCH SURROUNDING SURFACES. 3 TRANSITION TO GALVANIZED RMC ON THE BUILDING EXTERIOR FOR BOTH GATE OPERATOR POWER AND ACCESS CONTROL RACEWAYS. PAINT RACEWAYS TO MATCH SURROUDING SURFACES. 4 INSTALL GATE OPERATOR AND PEDESTAL ACCESS CONTROL CIRCUITRY UNDERGROUND. REFER TO TRENCH DETAIL #3/E-301 FOR ADDITIONAL INFORMATION. 5 PROVIDE PEDESTAL WITH HOOD, ACCESS CONTROL CARD READER AND LUMINAIRE. PROVIDE CONCRETE BASE. REFER TO PEDESTAL DETAIL #1/E-302 FOR ADDITIONAL INFORMATION. STUB-UP RACEWAYS WITHIN CONCRETE BASE AND OUT-OF-SIGHT. TRANSITION TO LIQUIDTIGHT WITHIN PEDESTAL TO MAINTAIN SEPARATION BETWEEN POWER AND ACCESS CONTROL CIRCUITRY. 6 STUB-UP GATE OPERATOR POWER RACEWAY AND BRANCH CIRCUITRY WITHIN GATE OPERATOR ENCLOSURE AND OUT-OF-SIGHT. 7 PROVIDE INDUCTIVE SENSING LOOP AS INDICATED. STUB-UP LOOP CIRCUITRY WITHIN GATE OPERATOR ENCLOSURE OUT-OF-SIGHT AND CONNECT TO LOOP DETECTOR. LOOP DETECTION CIRCUITRY MUST BE CONTINUOUS WITHOUT SPLICES. 8 DOOR CONTROLLER, POWER SUPPLY, AND ENCLOSURE BY OTHERS. 9 IN CONFERENCE ROOM 303, RECIRCUIT ALL OF THE RECEPTACLES TO LP-1-1. CIRCUIT LP-1-3 WILL BE FREED UP TO SERVICE THE UPPER GATE OPERATOR. 10 PROVIDE 2#12, 1#12G, 3/4" EMT FROM SPARE 20/1 CIRCUIT BREAKER #3 FOR UPPER GATE OPERATOR. MODIFY PANELBOARD DIRECTORY ACCORDINGLY. 11 PROVIDE CARD READER AND SECURE TO FENCE POST. 12 PROVIDE (2) 1" COREDRILLS THRU CMU WALL FOR UPPER GATE OPERATOR POWER AND PEDESTAL ACCESS CONTROL RACEWAYS. PATCH OPENINGS WITH GROUT AFTER RACEWAY INSTALLATION AND PAINT TO MATCH SURROUNDING SURFACES. 13 PROVIDE A TYPE "A" LUMINAIRE AND SURFACE MOUNT TO BRICK WALL FOR EXIT DISCHARGE EGRESS. INSTALL AT 8'-0" ABOVE FINISHED GRADE. COREDRILL WALL AND CIRCUIT INDOORS WITH 2#12, 1#12G, 3/4" EMT TO THE ADJACENT EXTERIOR LIGHT CIRCUIT, WHICH IS LOCATED +/- 100' AWAY. PROVIDE WITH AN UNSWITCHED POWER CONDUCTOR FOR THE LED EM BATTERY DRIVER. 14 PROVIDE A 13"x24"x12" COMPOSITE HANDHOLE. LABEL COVER "POWER" OR "SECURITY". PROVIDE WATERPROOF, SUBMERSIBLE RATED CONNECTORS FOR ALL TERMINATIONS IN HANDHOLES. 15 PROVIDE A TYPE "B" LUMINAIRE AND SURFACE MOUNT TO CARD ACCESS PEDESTAL. REFER TO DETAIL #1/E-302 FOR ADDITIONAL INFORMATION. 16 PROVIDE KNOX BOX WITH INTEGRAL MICROSWITCH. WIRE MICROSWITCH TO GATE OPERATOR, TO OPEN SLIDING GATE WHENEVER KNOX BOX IS OPENED. # SCALE: 1/8" = 1'-0"3 WATER TREATMENT PLANT - BASEMENT ELECTRICAL PLAN 0' 4' 8' 16' SCALE: 1/8"=1'-0" 0' 8' 16' 32' SCALE: 1/16"=1'-0" NOTE: REFER TO THE GATE CONTROLLER DETAIL (#3/E-401) AND THE TYPICAL GATE ENLARGED PLAN (#4/E-401) FOR ADDITIONAL INFORMATION. NOTE: REFER TO THE GATE CONTROLLER DETAIL (#3/E-401) AND THE TYPICAL GATE ENLARGED PLAN (#4/E-401) FOR ADDITIONAL INFORMATION. 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION X X X X X X X X X BRIDGE CASCADILLA STEAM 4403B BRIDGE CASCADILLA CHILLED WATER 4403A HUMPHREYS SERVICE BUILDING 2023 CENTRAL HEATING PLANT 5510B WATER TREATMENT PLANT 5510A CHILLED WATER PLANT III 5111 EAST ITHACA ENV. HLTH. 2080B MAPLE AVENUE PIPE/WELDING SHOP 2080C EAST ITHACA COMPLEX 115 KV MAPLE AVE SUB STATION CONTROL HOUSE 5376A THERMAL STORAGE TANK 5111A FUEL OIL TANK 5510E STEAM CONDENSER BUILDING 5510F FUEL OIL UNLOADING STATION 5510G CCHP PLANT 5510B CCHP OFFICE BUILDING 5510B 115 KV MAPLE AVE TRANSFORMERS 5376 CHP 5510B CHP GAS HOUSE 5510J MAPLE AVE 115KV SUBSTATION ANNEX 5376CTOWN OF ITHACACITY OF ITHACAENERGY DRIVENYS RT 366 CBCBCBCBCBCBCBCB CB 12' DOUBLE SWING GATE 50' - 0"50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0"50' - 0" 50' - 0"50' - 0" 1 GROUND ROD (TYPICAL) 2 FENCE BOND (TYPICAL) 3PEDESTRIAN GATE 3PEDESTRIAN GATE 4 12' DOUBLE SWING GATE 4 SLIDING GATE 5 5 SLIDING GATE 12' DOUBLE SWING GATE4 6SUBSTATION FENCE 7 OVERHEADELECTRIC UTILITY CROSSING O V E R H E A D E L E C T R IC U T IL IT Y C R O S S IN G OVERHEADEL ECT RI CUT I L I TY CROSSI NGO V ER H E A D E L E C T R I C U T I L IT Y N EA R BY OVERHEADELECTRICUTILITY CROSSING 12' DOUBLE SWING GATE9 PEDESTRIAN GATE8 10 GROUND ROD 11 FENCE BOND 12 EXISTING AQUEOUS AMMONIA TANK BURIED JUMPER BETWEEN ALL GATE OPENINGS (TYPICAL) 13 CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS E-102 11000237 FENCE GROUNDING AND BONDING PLAN C. WAYMAN CMW 5510A, 5510B OCTOBER 12, 2018 SCALE: 1" = 40'-0"1 FENCE GROUNDING/BONDING PLAN 0' 20' 40' 80' SCALE: 1"=40'-0" E-102 CONSTRUCTION KEY NOTES 1 AT EACH OVERHEAD ELECTRIC UTILITY CROSSING, PROVIDE BURIED GROUND RODS WITH TEST WELLS AS SHOWN. 2 PROVIDE #4/0 AWG BARE CU BONDING JUMPER FROM BURIED GROUND ROD TO VERTICAL FENCE POST. RUN CONTINUOUS WITH NO SPLICES. BURY BONDING JUMPER A MINIMUM OF 18" BELOW FINISHED GRADE. PROVIDE EXOTHERMICALLY WELDED CONNECTIONS AT THE GROUND ROD AND AT THE FENCE POST. 3 AT EACH PEDESTRIAN GATE, PROVIDE A #4/0 AWG BARE CU GATE JUMPER BETWEEN THE GATE AND THE SUPPORT POST. REFER TO DETAIL #1/E-401 FOR ADDITIONAL INFORMATION. 4 AT EACH DOUBLE SWING GATE, PROVIDE A #4/0 AWG BARE CU GATE JUMPER ON EACH SIDE, BETWEEN THE GATE AND EACH SUPPORT POST. REFER TO DETAIL #1/E-401 FOR ADDITIONAL INFORMATION. 5 BOND EACH SLIDING GATE PER THE MANUFACTURER'S RECOMMENDATIONS. 6 DO NOT CONDUCTIVELY CONNECT, BOND, OR JUMPER THE EXISTING MAPLE AVENUE SUBSTATION FENCE TO THE NEW FENCE. PROVIDE NON-CONDUCTIVE FENCING MATERIAL AND POSTS WHERE THE FENCE SYSTEMS MEET. MAINTAIN A MINIMUM 8'-0" SEPARATION BETWEEN THE FENCE SYSTEMS. 7 PROVIDE NON-CONDUCTIVE SIGNAGE ON THE NON-CONDUCTIVE FENCE PANEL AT EACH SIDE OF THE SUBSTATION (AND ON BOTH SIDES OF THE FENCE) TO READ AS FOLLOWS, "WARNING - FENCE ISOLATION PANEL - THIS FENCE PANEL SHALL HAVE NO ELECTRICALLY CONDUCTIVE CONNECTION TO THE ADJACENT MAPLE AVE. SUBSTATION FENCE". 8 AT AMMONIA TANK PEDESTRIAN GATE, PROVIDE A #1/0 AWG BARE CU GATE JUMPER BETWEEN THE GATE AND THE SUPPORT POST. REFER TO DETAIL #1/E-401 FOR ADDITIONAL INFORMATION. 9 AT AMMONIA TANK DOUBLE SWING GATE, PROVIDE A #1/0 AWG BARE CU GATE JUMPER ON EACH SIDE, BETWEEN THE GATE AND EACH SUPPORT POST. REFER TO DETAIL #1/E-401 FOR ADDITIONAL INFORMATION. 10 AT AMMONIA TANK FENCE, PROVIDE A BURIED GROUND ROD WITH TEST WELL AS SHOWN. 11 AT AMMONIA TANK FENCE, PROVIDE #1/0 AWG BARE CU BONDING JUMPER FROM BURIED GROUND ROD TO VERTICAL FENCE POST. RUN CONTINUOUS WITH NO SPLICES. BURY BONDING JUMPER A MINIMUM OF 18" BELOW FINISHED GRADE. PROVIDE EXOTHERMICALLY WELDED CONNECTIONS AT THE GROUND ROD AND AT THE FENCE POST. 12 PROVIDE A #1/0 AWG BARE CU BONDING JUMPER BETWEEN THE EXISTING FENCE POST AND THE NEW FENCE POST. BOND THE NEW BARBED WIRE ADDED TO THE EXISTING FENCE. REFER TO DETAIL #1/E-401 FOR ADDITIONAL INFORMATION. 13 PROVIDE A BURIED BONDING JUMPER (#4/0 AWG CU BARE AT THE MAIN PERIMETER FENCE AND #1/0 AWG CU BARE AT THE AMMONIA TANK FENCE) TO BOND BOTH SIDES OF GATE OPENINGS. BURY A MINIMUM OF 18" BELOW FINISHED GRADE. APPLIES TO ALL PEDESTRIAN GATES, DOUBLE SWING GATES, AND SLIDING GATES. # FENCE GROUNDING GENERAL NOTES 1.0 GROUNDING LOCATIONS SHALL NOT EXCEED 160-FEET. 2.0 GROUND ROD ELECTRODES SHALL BE 3/4"x10' LONG, COPPER-CLAD STEEL. 3.0 GROUNDING CONDUCTORS AND BONDING JUMPERS SHALL BE CONNECTED TO THE FENCE WITH EXOTHERMICALLY WELDED CONNECTIONS TO CREATE ELECTRICAL CONTINUITY BETWEEN FENCE POSTS, FENCE FABRIC, AND GROUND RODS. 4.0 TOTAL RESISTANCE OF FENCE TO GROUND SHALL NOT BE GREATER THAN 25-OHMS. 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION FENCE GROUNDING CLAMP ULTRAWELD CONNECTIONS #4/0 AWG CU BARE GROUNDING CONDUCTOR GATE JUMPER WITH ULTRAWELD CONNECTIONS CONNECT FENCE BONDING CONDUCTOR TO GROUND CONDUCTOR WITH ULTRAWELD CONNECTION #4/0 AWG CU BARE GROUNDING CONDUCTOR #4/0 AWG CU BARE GROUNDING CONDUCTOR TO GROUND ROD COPPER CLAD GROUND ROD COPPER GROUNDING CONDUCTOR TEST WELL SAFETY LOOP EXIT LOOP UE UC 6' - 0" 6' - 0" 6' - 0" 12' - 0" 6' - 0" 12' - 0" UCUCUCUE UE UEUEUEUCUCUEUC UC UE UC UE UE UE UE CARD READER MOUNTED TO PEDESTAL (SLIDING GATE) PEDESTAL 3/4" PVC SCHD 40 (CARD READER CIRCUITRY TO DOOR CONTROLLER) 3/4" PVC SCHD 40 (PEDESTAL LUMINAIRE POWER) COMPOSITE HANDHOLE (ACCESS CONTROL WIRING) 3/4" PVC SCHD 40 TO DOOR CONTROLLER 3/4" PVC SCHD 40 TO PANELBOARD COMPOSITE HANDHOLE (GATE OPERATOR AND PEDESTAL LUMINAIRE POWER) 3/4" PVC SCHD 40 (GATE CONTROLS) 3/4" PVC SCHD 40 (GATE POWER) GATE OPERATOR 3/4" PVC SCHD 40 (PHOTOEYE) KNOX BOX 3/4" PVC SCHD 40 (PEDESTRIAN GATE ACCESS CONTROL, CRASH BAR, AND DOOR POSITION SENSOR) 3/4" PVC SCHD 40 (POWER TO CRASH BAR AND DOOR POSITION CONTACT) PEDESTRIAN GATE CARD READER MOUNTED TO FENCE (PEDESTRIAN GATE) PEDESTRIAN GATE CRASHBAR SLIDING GATE SLIDING GATE LOCKING MECHANISM 3/4" PVC SCHD 40 (LOCKING MECHANISM) 3/4" PVC SCHD 40 (PHOTOEYE) 1/2" PVC SCHD 40 (LOOP DETECTOR) 1/2" PVC SCHD 40 (LOOP DETECTOR) KB CR CRLC L PEPE DOOR POSITION CONTACT B LED LIGHT FIXTURE ABOVE CARD READER GND PHASE NEUTRAL KNOX BOX W/ MICROSWITCH SAFETY LOOP DETECTOR EXIT LOOP DETECTOR PHOTOEYE PHOTOEYE ELECTRO MECHANICAL LOCK MECHANISM GATE OPERATOR CONTROLLER ENCLOSURE 20A/120VAC BRANCH CIRCUIT SAFETY LOOP EXIT LOOP GATE OPERATOR CONTROLLERLENEL DOOR CONTROLLER CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS E-401 11000237 DETAILS C. WAYMAN CMW 5510A, 5510B OCTOBER 12, 2018 SCALE: NO SCALE 1 TYPICAL FENCE & GATE BONDING DETAIL SCALE: NO SCALE 2 TYPICAL GROUND ROD TEST WELL DETAIL SCALE: NO SCALE 4 GATE ENLARGED PLAN - CONDUIT ROUTING SCALE: NO SCALE 3 GATE CONTROLLER WIRING DIAGRAM GATE OPERATOR WIRING LEGEND TYPE WIRE CONDUIT NOTES CARD READER (2)-PAIR #20AWG CU 3/4" KNOX BOX (1)-PAIR #20 AWG CU 3/4" LOOP DETECTOR HARNESS BY MANUF. - LOOP (1)-PAIR #16 AWG XHHW 1/2" RUN CONTINUOUS - NO SPLICES; TWIST TOGETHER 6 TURNS/FOOT BETWEEN CONTROLLER AND LOOP PHOTOEYE (2)-PAIR #20AWG CU 3/4" LOCK MECHANISM (1)-PAIR #20AWG CU, (1)-PAIR #12 AWG CU 3/4" 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION NEW LENEL DOOR CONTROLLER (BY OTHERS) NEW LENEL LNL-1320 SERIES 2 DUAL READER INTERFACE (DRI) MODULE (BY OTHERS) SLIDING GATE CARD READER SLIDING GATE OPERATOR CONTROLLER PEDESTRIAN GATE CRASH BAR (LATCH RETRACTION) PEDESTRIAN GATE CARD READER (3) PAIR #22 CU AWG TSP (1) PAIR #18 CU AWG (3) PAIR #22 CU AWG TSP (1) PAIR #18 CU AWG EXISTING LENEL DOOR CONTROLLER NEW LENEL ENCLOSURE (BY OTHERS) (2) PAIR TSP, 3/4" EMT (BY OTHERS) LCRC CR PEDESTRIAN GATE DOOR POSITION CONTACT BASEMENT EXTERIOR NEW LENEL DOOR CONTROLLER (BY OTHERS) NEW LENEL LNL-1320 SERIES 2 DUAL READER INTERFACE (DRI) MODULE (BY OTHERS) SLIDING GATE CARD READER SLIDING GATE OPERATOR CONTROLLER PEDESTRIAN GATE CRASH BAR (LATCH RETRACTION) PEDESTRIAN GATE CARD READER (3) PAIR #22 CU AWG TSP (1) PAIR #18 CU AWG (3) PAIR #22 CU AWG TSP (1) PAIR #18 CU AWG EXISTING LENEL DOOR CONTROLLER NEW LENEL ENCLOSURE (BY OTHERS) (2) PAIR TSP, 3/4" EMT (BY OTHERS) LCRC CR PEDESTRIAN GATE DOOR POSITION CONTACT CORRIDOR 300CJ EXTERIOR CORN E LL U N I V E R SI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 CENTRAL ENERGY PLANT CEP PHYSICAL SECURITY IMPROVEMENTS E-402 11000237 ACCESS CONTROL RISER DIAGRAMS C. WAYMAN CMW 5510A, 5510B OCTOBER 12, 2018 SCALE: NO SCALE 1 ACCESS CONTROL RISER DIAGRAM - WATER TREATMENT PLANT SCALE: NO SCALE 2 ACCESS CONTROL RISER DIAGRAM - CCHPP 1 8/31/2018 ISSUE FOR DD REVIEW 2 9/12/2018 ISSUE FOR FIRE AHJ REVIEW 3 10/11/2018 ISSUE FOR COORDINATED REVIEW 4 10/12/2018 ISSUE FOR CONSTRUCTION