HomeMy WebLinkAboutTC2.20TELECOM - LEVEL 22 2 822
22 622
2 444
2
2
WAP
WAPWAPWAPWAP
86444
4
4
4
4
4
4
4
4
4
4
22244
2
2 2
2
22
22
1
1
21 3 4 6 7 8
5
Q
P
R
S
T
O
U
9
S1
R1
4A
Q1
5.1
WORK AREA
TISSUE CULTURE
(MAMMALIAN)
276B
TISSUE CULTURE
(BACTERIAL)
276C
GLASSWASH
276A
LAB WRITE-UP
260
LAB WRITE-UP
269
OPEN RESEARCH
LAB
276
? ?
?
iCVD ROOM
276D
Room
200SD
Room
255A
Room
252Room
254
Room
256
Room
267
CO2 CLOSET
200JA
ELECTRICAL
200UA
PLUMBING
200UB
ACCESSIBLE
RESTROOM
200TC
C
C C
C
C
C
C
C
CC
LOCATE IN
WIREMOLD
C C
C
CC
OSC
OSC
OSC
OSC
OSC
OSC
CC
DATA FOR SECURITY SYSTEM
DATA FOR SECURITY SYSTEM
Architect
Payette Associates Architects, P.C.
290 Congress Street, Fifth Floor
Boston, MA 02210-1005
Tel: 617-895-1000
Fax: 617-895-1002
MEP/FP Engineer
Vanderweil
274 Summer Street
Boston, MA 02210
Tel: 617-423-7423
Structural Engineer
SGH
41 Seyong Street
Building 1, Suite 500
Waltham, MA 02453
Tel: 781-907-9000
Fax: 781-907-9009
Drawing Scale
Project Number
Date Issued
Renovation of Olin Hall for
Chemical and Biomolecular
Engineering - Phase 1
Code Consultant
Hastings Consulting Inc
142 Hanlon Road
Hollister, MA 01746
Tel: 508-397-8417
Lighting Designer
Available Light
10 Derby Square #3
Salem, MA 01970
Tel: 978-744-6800
N
Cost Consultant
Dharam Consulting
745 Atlantic Ave Fl 8
Boston, MA 02111
Tel: 617-913-4345
Abatement Specialist
Delta
860 Hooper Rd
Endwell, NY 13760
Tel: 607-231-6600
Civil Engineer
T.G. Miller, P.C.
203 N. Aurora Street
Ithaca, NY 14850
Tel: 607-272-6477
1/4" = 1'-0"
TC2.20
29313.00
11/30/18
TELECOM - LEVEL 2
1/4" = 1'-0"1 TELECOM - LEVEL 2 - A
NOTES:
LAB BENCH OUTLETS ARE FED FROM OVERHEARD SERVICE CARRIER. SEE DETAIL #2 ON SHEET TC4.01.
IDENTIFY THE EXISTING CABLE TRAY WITHIN THE PROJECT AREA AND IN AREAS THAT WILL BE IMPACTED BY BUILDING SYSTEMS
RELATED TO THE PROJECT. THIS INCLUDES AREAS WHERE MECHANICAL SYSTEM ALTERATIONS WILL IMPACT THE EXISTING
CABLE TRAY.
IDENTIFY LOCATIONS WHERE THE EXISTING TRAY NEEDS TO BE MOVED, ALTERED, OR REMOVED AND REPLACED, TO
ACCOMMODATE NEW OR MODIFIED DUCTWORK, PLUMBING, ELECTRICAL SERVICES, AND OTHER BUILDING SYSTEMS.
PROVIDE THE TEMPORARY CABLE SUPPORTS AND/OR NEW CABLE SUPPORTS TO ENSURE THAT THE COMMUNICATIONS
CABLING IS PROTECTED AND SUPPORTED THROUGHOUT THE PROJECT. PROVIDE CABLE PROTECTION FOR CABLING WITHIN
AFFECTED AREAS. IN CASES WHERE THE EXISTING CABLING DOES NOT HAVE SUFFICIENT SLACK TO ALLOW IT TO BE MOVED
OUT OF THE AFFECTED AREA, COORDINATE SCHEDULING OF NEW CABLE INSTALLATION WITH CIT AND PROVIDE NEW CABLING,
WITH SUFFICIENT SLACK, FROM THE EXISTING IDF ROOM TO REPLACE EACH OF THE AFFECTED CABLES. TERMINATE, LABEL,
AND TEST NEW CABLING.
COORDINATE CABLE TRAY MODIFICATIONS WITH CIT, THE CONTRACTOR, AND THE PROJECT SCHEDULE.COMPLY WITH CIT
STRUCTURED CABLING SYSTEM STANDARDS AND REFERENCED STANDARDS IN THE DESIGN DOCUMENTS. RESTORE CABLE
TRAY, IN COMPLIANCE WITH CIT STANDARDS IN THE AFFECTED AREAS.
# DATE DESCRIPTION
1 11/30/18 ISSUED FOR CONSTRUCTION
2 12/18/18 ADDENDUM 01
3 1/7/18 ADDENDUM 02
3