Loading...
HomeMy WebLinkAboutP5.01PLUMBING- DETAILSCARPET CLIPUNFINISHED ORCARPETED FLOORFINISHED SLABNICKEL BRONZE TOPSET SCREWFINISHED FLOORFINISHED SLABCAST IRON CLEANOUTBODY WITH PUSH-ONGASKETADJUSTABLE TOPHOUSINGGASKETED CONNECTIONPVC CLEANOUT PIPEBRONZE CLEANOUTPLUG WITH GASKETEDSEALRISER CLAMP1/2" MIN1 1/2"SERVICE PIPESCHEDULE 40 PIPE ONENOMINAL SIZE LARGERTHAN SLEEVESLEEVE, MINIMUM ONENOMINAL SIZE LARGERTHAN RISERFLOOR SLABFLOOR FLANGEMETAL DECKUL LISTED FIRE STOPPINGASSEMBLY TO MATCHFLOOR RATINGNOTES:1. REFER TO DETAILS ON STRUCTURAL DWG'S FOR LOCATIONS WHERE MULTIPLE PIPE PENETRATIONS ARE REQUIRED. 2. ASSEMBLY SHALL BE UL APPROVED ASSEMBLY FOR PIPE TYPE & PENETRATION TYPE. REFER TO DIVISION 7 FOR FIRESTOPPING REQUIREMENTS. SLOPE TO DRAINNOTE:WHERE EDGE OF FLOOR DRAIN ISWITHIN 24 INCHES OF WALL, ADJUSTSLOPE TO SUIT INSTALLATION. CAST IRON DRAIN BODYWITH PUSH-ON GASKETDRAININSTALL FLOOR DRAIN 1/2"BELOW FINISHED FLOOR.CONCRETE TRADE SHALLFINISH THE TOP OF FLOORFLUSH WITH DRAIN.TILE WHERE APPLICABLE1/2"NOTE:WHERE EDGE OF FLOOR DRAIN IS WITHIN 24 INCHES OF WALL,ADJUST SLOPE TO SUIT INSTALLATION.CAST IRON DRAIN BODYWITH PUSH-ON GASKETDRAININSTALL FLOOR DRAIN1/2" BELOW FINISHEDFLOOR. CONCRETETRADE SHALL FINISH THETOP OF FLOOR FLUSHWITH DRAIN.SLOPE TO DRAINREFER TOPLANSPIPE CLAMPFINISHED FLOOR SLABFOOTINGIRON STRAP5/8" RODFOUNDATION WALLFLEXIBLE JOINTASSEMBLY (TYP.)MECH. RESTRAINTCOLLAR (TYP. FOR 2)WATERTIGHT PENETRATIONASSEMBLY4"0' - 0 19/32"0' - 0 1/2"MODULAR MECHANICALSEALSERVICEPIPESTEEL SLEEVE WITHWELDED WATER STOPCOLLARCONCRETE WALL/FLOORSTAINLESS STEELBOLT/NUTPRESSURE PLATES8" X 8" GRADE CLEANOUT. POLISHEDBRONZE FRAME, AND HINGEDCOVER, W/CI CLEAN OUT PLUGFINISHED GRADESANITARY OR DRAIN LINEBELOW GRADE. SIZED ASSHOWN ON DRAWINGS4" RISE TO GRADE.24" X 24" X 4" CONCRETEPAD FLUSH WITH GRADEFINISHED FLOORNICKEL BRONZE TOPSET SCREWFINISHED FLOORFINISHED SLABCAST IRON CLEANOUTBODY WITH PUSH-ONGASKETAJUSTABLE TOP HOUSINGGASKETED CONNECTIONCAST IRON CLEANOUT PIPEBRONZE CLEANOUT PLUGWITH GASKETED SEALNOTE:WHERE INSTALLING WITHIN AN EXISTING SLAB, SLABWILL NEED TO BE CUT, CLEANOUTS PLACED, ANDREPOURED. COORDINATE WITH CONCRETE CONTRACTOR.72"ABOVE ROOFROOFSCREENROOF DECKSLOPE DOWN TO PUMPDRAIN VALVEROOFING MEMBRANEFLASHING (BY OTHERS)TURN DOWN ELBOWPROVIDE W/SCREENSTAINLESS STEEL CLAMPFRICTION CLAMP TO STRUCTUREWITH 4 WAY BRACEPROVIDE LOW POINTDRAIN AT TRAPSSTAINLESS STEELEXHAUST PIPESTAINLESS STEEL CLAMP4'-6"FINISHED FLOORNATURAL GAS ISOLATIONVALVE IN CABINETGAS CABINET WITH GLASSDOOR(REFER TO SPECIFICATION)NATURAL GASSERVICE TO LAB OUTLETSNATURAL GASSERVICEGAS PIPING IN WALLArchitectPayette Associates Architects, P.C.290 Congress Street, Fifth FloorBoston, MA 02210-1005Tel: 617-895-1000Fax: 617-895-1002MEP/FP EngineerVanderweil274 Summer StreetBoston, MA 02210Tel: 617-423-7423Structural EngineerSGH41 Seyong StreetBuilding 1, Suite 500Waltham, MA 02453Tel: 781-907-9000Fax: 781-907-9009Drawing ScaleProject NumberDate IssuedRenovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code ConsultantHastings Consulting Inc142 Hanlon RoadHollister, MA 01746Tel: 508-397-8417Lighting DesignerAvailable Light10 Derby Square #3Salem, MA 01970Tel: 978-744-6800NCost ConsultantDharam Consulting745 Atlantic Ave Fl 8Boston, MA 02111Tel: 617-913-4345Abatement SpecialistDelta860 Hooper RdEndwell, NY 13760Tel: 607-231-6600Civil EngineerT.G. Miller, P.C.203 N. Aurora StreetIthaca, NY 14850Tel: 607-272-6477NTSP5.0129313.0011/30/18PLUMBING- DETAILSSCALE:NTS1FLOOR CLEANOUTSCALE:NTS2INDIVIDUAL PIPE PENETRATION PIPE RISER SUPPORTSCALE:NTS3FINISHED FLOOR DRAINSCALE:NTS4UNFINISHED FLOOR DRAINSCALE:NTS5WATER SERVICE THRU FOUNDATION WALLSCALE:NTS6WATERTIGHT PIPE PENETRATIONSCALE:NTS9GRADE CLEANOUTSCALE:NTS10FLOOR CLEAN OUTSCALE:NTS7VACUUM PUMP EXHAUSTSCALE:NTS8LOCAL NATURAL GAS VALVE IN CABINET# DATE DESCRIPTION1 11/30/18 ISSUED FOR CONSTRUCTIONDocuSign Envelope ID: D6CBE973-BBA9-4BE0-861E-C2F6DD72B53912/10/2018