Loading...
HomeMy WebLinkAboutP4.40PLUMBING - VACUUM RISER DIAGRAMM MLAB EQUIPMENTE-BEAMDEPOSITION ROOMiCVD ROOMTISSUE CULTURE(BACTERIAL)TISSUE CULTURE(MAMMALIAN)OPEN RESEARCHLABOPEN RESEARCHLABOPEN RESEARCHLABRESEARCH LABRESEARCH LABSUPPORT 1SUPPORT 2VAC1-SET @ 80 PSIVEVACCOMPRESSEDAIRVAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VAC3/4" VACVACOUTLET 0.5 CFM OUTLET 0.5 CFM FUME HOOD 0.5 CFM FUME HOOD 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM FUME HOOD 0.5 CFM FUME HOOD 0.5 CFM FUME HOOD 0.5 CFM FUME HOOD 0.5 CFM OUTLET 0.5 CFM FUME HOOD 0.5 CFM FUME HOOD 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM FUME HOOD 0.5 CFM FUME HOOD 0.5 CFM OUTLET 0.5 CFM FUME HOOD0.5 CFM VACVACVACVACVACVACVACVACVACOUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM OUTLET 0.5 CFM LEVEL 2LEVEL 3BASEMENTLEVEL 1LEVEL 4BASEMENTLEVEL 2LEVEL 3LEVEL 4LEVEL 1LEVEL 2LEVEL 3LEVEL 4LEVEL 2LEVEL 3LEVEL 4CC(VENDOR PACKAGE)DRAIN (TYPICAL)VACUUMRECEIVERVEVACUUM PUMP SKIDAUTOMATICDRAINVACUUM PUMP EXHAUST THRU ROOFLOW POINT DRAINSIGHT GLASSDRAIN2" [17.5 acfm]2" [42 acfm]2" [42 acfm]2" [24.5 acfm]3/4" VAC [1 CFM]REFER TOLABBENCHDETAIL3/4" VAC [1 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4" VAC [1 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4" VAC [2 CFM]REFER TOLABBENCHDETAIL3/4"3/4"1. AUTO DRAIN VALVE ON VACUUM RECEIVER.NOTES:2. CONNECT TO BMS FOR OPERATION AND ALARMING CAPABILITIES.3/4"3/4"DEVELOPED LENGTH = 350'PUMP PRESSURE = 25 IN HgDESIGN PRESSURE AT INLET = 20 IN HgALLOWABLE PRESSURE DROP = 5 IN HgPRESSURE DROP / 100 FT = 1.25 IN Hg1 INLET = 0.5 SCFMPITPSVPIPIPCVPIPIArchitectPayette Associates Architects, P.C.290 Congress Street, Fifth FloorBoston, MA 02210-1005Tel: 617-895-1000Fax: 617-895-1002MEP/FP EngineerVanderweil274 Summer StreetBoston, MA 02210Tel: 617-423-7423Structural EngineerSGH41 Seyong StreetBuilding 1, Suite 500Waltham, MA 02453Tel: 781-907-9000Fax: 781-907-9009Drawing ScaleProject NumberDate IssuedRenovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code ConsultantHastings Consulting Inc142 Hanlon RoadHollister, MA 01746Tel: 508-397-8417Lighting DesignerAvailable Light10 Derby Square #3Salem, MA 01970Tel: 978-744-6800NCost ConsultantDharam Consulting745 Atlantic Ave Fl 8Boston, MA 02111Tel: 617-913-4345Abatement SpecialistDelta860 Hooper RdEndwell, NY 13760Tel: 607-231-6600Civil EngineerT.G. Miller, P.C.203 N. Aurora StreetIthaca, NY 14850Tel: 607-272-6477NTSP4.4029313.0011/30/18PLUMBING - VACUUMRISER DIAGRAM# DATE DESCRIPTION1 11/30/18 ISSUED FOR CONSTRUCTIONDocuSign Envelope ID: D6CBE973-BBA9-4BE0-861E-C2F6DD72B53912/10/2018