P2.20PLUMBING - LEVEL 2
21346785QPRSTOU9S1R14AQ15.1CO2 MANIFOLDPHASE 1 SCOPE BOUNDARYLS-1EW-1LS-2EW-1LS-1EW-1LS-1EW-1LS-1EW-1LS-1EW-1LS-1EW-1FHCS-1FHFHFHFHFHFH4" FD-C4" FD-CES-1TMV-1WC-1AL-1AUCD-1GW-1IM-14" FD-C3/4" N2-1003/4" CA-1001 1/2" VAC1 1/2" VAC3/4" CA-1003/4" N2-100111011112232222FHCS-133P5.034P5.037P5.038P5.012" LW UP3" LW464646467SK-232mm PWS UP & DN32mm PWR UP & DN1" LHW UP & DN1-1/2" LCW UP & DN3/4" LHWR UP & DN1" N2 UP & DN1" CA UP & DN2" VAC UP & DN2-1/2" G(EX) UP & DN 2-1/2" CW(EX) UP & DN2" HW(EX) UP & DN3/4" HWR UP & DNPWS1N21PWR1CA1LHW1VAC1LCW1G1LHWR1CW1HW11" CW DROP4" SAN DN & 2" V RISE4" LW & T UP2" LV UP2" LW UP2" LW UP4" LW & T UP2" LW UP4" LW2" LW2" LV UP4" LW DN1/2" HW DROP2" W DN & V RISE1/2" CW DROP3/4" G DROP2" LW DN &LV RISE2" LV DN &RISE2" LW DN &LV RISETISSUE CULTURE(MAMMALIAN)276BTISSUE CULTURE(BACTERIAL)276CGLASSWASH276ALAB WRITE-UP260LAB WRITE-UP269OPEN RESEARCHLAB276iCVD ROOM276DRoom200SDRoom255ARoom252Room254Room256Room267CO2 CLOSET200JAELECTRICAL200UAPLUMBING200UBACCESSIBLERESTROOM200TCP5.036878ES-1TMV-19944444584757541 1/2" CW1" HW1 1/2" LCW1" LHW1" PWS1 1/2" CW1" HW1 1/2" LCW1" LHW1" PWS3/4" HWR1" PWR3/4" LHWR44444441/2" N2-1001/2" CA-1003/4" VACCTE G W/ 3/4" GCTE CW W/ 1-1/2" CWCTE HW W/ 1" HW3/4" G4444OPEN RESEARCHLAB276112" LV UP2" LV UP2" LV UP2" LV2" LV2" LV2" LV3" V UP2" LV2" LV DN1/2" HW DROP2" W & V1/2" CW DROP1010110102" STANDPIPE DRAIN2" LW DN & LV RISE2" V2" V2" V3" HWR11 1/2" VAC3/4" CA-1003/4" N2-1001 1/2" VAC3/4" CA-1003/4" N2-1001" PWS1" LHW1 1/2" LCW1" HW3/4" N2-1003/4" CA-1001 1/2" VAC3" V UP & DN3" VE UP & DNWB-1COCOCOCO1/4" / 12"1/8" / 12"1 1/2" VAC3/4" CA-1003/4" N2-1001" HW1 1/2" LCW1" LHW1" PWS2P5.041/2" N2-1001/2" CA-1003/4" VAC1/2" N2-1001/2" CA-1003/4" VACCOMMON AREA260A1 1/4" CW1/2" HW4" LW DN2" LW3" LW4" LW1/8" / 12"COCO1 1/2" CW1 1/2" CW33/4" VAC1/2" CA-1001/2" N2-1001" PWR3/4" LHWR3/4" HWR33/4" G3/4" G DROP3/4" G RISE3/4" VAC1/2" CA-1001/2" N2-1003/4" VAC1/2" CA-1001/2" N2-10031/2" CO23/4" G1/2" N2-1001/2" CA-1003/4" VAC1 1/2" CW1" HW1 1/2" LCW1" LHW1" PWS1 1/2" CW1" HW1 1/2" LCW1" LHW1" PWS331/2" LCW3ArchitectPayette Associates Architects, P.C.290 Congress Street, Fifth FloorBoston, MA 02210-1005Tel: 617-895-1000Fax: 617-895-1002MEP/FP EngineerVanderweil274 Summer StreetBoston, MA 02210Tel: 617-423-7423Structural EngineerSGH41 Seyong StreetBuilding 1, Suite 500Waltham, MA 02453Tel: 781-907-9000Fax: 781-907-9009Drawing ScaleProject NumberDate IssuedRenovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code ConsultantHastings Consulting Inc142 Hanlon RoadHollister, MA 01746Tel: 508-397-8417Lighting DesignerAvailable Light10 Derby Square #3Salem, MA 01970Tel: 978-744-6800NCost ConsultantDharam Consulting745 Atlantic Ave Fl 8Boston, MA 02111Tel: 617-913-4345Abatement SpecialistDelta860 Hooper RdEndwell, NY 13760Tel: 607-231-6600Civil EngineerT.G. Miller, P.C.203 N. Aurora StreetIthaca, NY 14850Tel: 607-272-6477 1/4" = 1'-0"P2.2029313.0011/30/18PLUMBING - LEVEL 2 1/4" = 1'-0"1PLUMBING - LEVEL 2 - PHASE 125mm PWS DROP25mm PWS RISE1/2" LCW DROP2" LW DN & 2" LV RISE1/2" LHW DROP3/4" VAC DROP1/2" N2-100 DROP1/2" CA-100 DROP1/2" LCW DROP3/4" VAC DROP1/2" N2-100 DROP1/2" CA-100 DROP3/4" VAC DROP1/2" N2-100 DROP1/2" CA-100 DROP1/2" CA-100 DROP1/2" N2-100 DROP3/4" VAC DROPKEYNOTES:1231P5.032P5.035P5.03NOTES:1. ALL PIPE PENETRATIONS SHALL BE FIREPROOFED IN ACCORDNACE WITH SPECIFICATIONS & LOCAL CODE.5678941/2" CO2 DROP1" CW & 3/4" HW DROP TO TMV-1. EXTEND 1" TW FROM MIXING VALVE TO ES-1.1/2" CW & 1/2" HW DROP TO TMV-2. EXTEND 1/2" TW FROM MIXING VALVE TO EW-1.10# DATE DESCRIPTION1 11/30/18 ISSUED FOR CONSTRUCTION2 12/18/18 ADDENDUM 013 1/7/18 ADDENDUM 02DocuSign Envelope ID: 495E9EAC-9F74-4159-ACA0-7B8831B044F51/4/2019