Loading...
HomeMy WebLinkAboutP0.01PLUMBING LEGEND & GENERAL NOTESXXYXYXYZXSPIPE ACCESSORIESSYMBOLSPLUMBING FIXTURESREFERENCEPIPE FITTINGS* NOT ALL SYMBOLS MAY BE APPLICABLE TO THIS PROJECTCHECK VALVEPIPE DIRECTION OF SLOPE DOWNHOSE BIBBBALL VALVERPBP OR RPZMIXING VALVEPIPE DIRECTION OF FLOWFLOOR DRAIN / FLOOR SINKGROUND HYDRANTX: DETAIL DESIGNATION NUMBERY: DETAIL DESIGNATION DRAWINGX: RISER SERVICE DESIGNATIONY: RISER NUMBER DESIGNATIONZ: RISER DESIGNATION DRAWINGX: KEYNOTE DESIGNATION LETTERWALL HYDRANTX: REVISION TAG DESIGNATION NUMBERPRESSURE REDUCING VALVEGATE VALVE (CLOSED)HANDICAPPED ACCESSIBLE (HC)GAS COCK VALVEPRESSURE RELIEF VALVESOLENOID VALVEGATE VALVE (OPEN)SHUTOFF VALVEEARTHQUAKE GAS VALVEBACKWATER VALVEFLOW SWITCH (TO BMS)P-TRAPCAP OR END OF PIPEFLOOR OR GRADE CLEANOUTREDUCER OR INCREASERCLEANOUTX: SECTION DESIGNATION NUMBERY: SECTION DESIGNATION DRAWINGSlopeFSDIAPHRAGM VALVE (OPEN)SANITARY CONNECTIONDIAPHRAGM VALVE (CLOSED)ArchitectPayette Associates Architects, P.C.290 Congress Street, Fifth FloorBoston, MA 02210-1005Tel: 617-895-1000Fax: 617-895-1002MEP/FP EngineerVanderweil274 Summer StreetBoston, MA 02210Tel: 617-423-7423Structural EngineerSGH41 Seyong StreetBuilding 1, Suite 500Waltham, MA 02453Tel: 781-907-9000Fax: 781-907-9009Drawing ScaleProject NumberDate IssuedRenovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code ConsultantHastings Consulting Inc142 Hanlon RoadHollister, MA 01746Tel: 508-397-8417Lighting DesignerAvailable Light10 Derby Square #3Salem, MA 01970Tel: 978-744-6800NCost ConsultantDharam Consulting745 Atlantic Ave Fl 8Boston, MA 02111Tel: 617-913-4345Abatement SpecialistDelta860 Hooper RdEndwell, NY 13760Tel: 607-231-6600Civil EngineerT.G. Miller, P.C.203 N. Aurora StreetIthaca, NY 14850Tel: 607-272-6477 12" = 1'-0"P0.0129313.0011/30/18PLUMBING LEGEND &GENERAL NOTESPLUMBING ABBREVIATIONS - DOMESTIC FIXTUREBTBATH TUBDF DRINKING FOUNTAINEWC ELECTRIC WATER COOLERHB HOSE BIBB W/ VACUUM BREAKERJS JANITOR SINKLLAVATORYMSB MOP SERVICE BASINSHSHOWERSKSINKSS SERVICE SINKURURINALWC WATER CLOSETWH WALL HYDRANTPLUMBING NOTES - GENERAL1. GENERAL NOTES, SYMBOLS LIST AND DETAILS ARE APPLICABLE TO ALLDRAWINGS MARKED P AND OR FP.2. DRAWINGS ARE DIAGRAMATIC: DETERMINE LOCATIONS OF SYSTEMS ANDCOMPONENTS IN FIELD.3. DIMENSIONS SHOWN ON PLAN ARE HORIZONTAL. DIMENSIONS SHOWN INELEVATION ARE VERTICAL.4. DETERMINE EXACT LOCATIONS IF EXISTING UTILITIES IN FIELD, WHETHEROR NOT SHOWN ON DRAWINGS. EXERCISE CAUTION AND IDENTIFYLOCATIONS OF UNMARKED UTILITY LINES AS NECESSARY TO PERFORMWORK OF THIS SECTION.5. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH THE LATESTPLUMBING CODE AND ALL APPLICABLE LOCAL CODES.6. IT SHALL BE THE RESPONSABILITY OF THIS CONTRACTOR TO COORDINATETHE WORK WITH THAT OF ALL OTHER TRADES, INCLUDING BUT NOT LIMITTO, ELECTRICAL, HVAC, PROCESS PIPING, SPRINKLER, PLUMBING,STRUCTURAL AND GENERAL ARCHITECTURE.7. ANY INTERFERENCE SHALL BE BROUGHT TO THE ATTENTION OF THEOWNER'S REPRESENTATIVE, AND SHALL BE RESOLVED PRIOR TO THEINSTALLATION OF THE WORK.8. NO WORK SHALL BE INSTALLED IN VIOLATION OF ANY GOVERNING CODES.ANY WORK SHOWN ON THE DRAWINGS WHICH IS IN VIOLATION OF SUCHCODES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'SREPRESENTATIVE AND SHALL BE RESOLVED PRIOR TO THE INSTALLATIONOF THE WORK.9. ALL PIPING PENETRATING CEILINGS AND WALL SHALL BE INSTALLED WITHESCUTCHEONS AT THE PENETRATON. ALL PIPING PENETRATING EXTERIORWALLS AND ROOFS SHALL BE FLASHED IN AN APPROVED MANNER ANDSHALL BE SEALED WEATHERTIGHT. PIPING PENETRATING FIRE RATEDPARTITIONS SHALL BE PROVIDED WITH FIRE RATED SEALS AS REQUIRED BYLOCAL CODE AUTHORITY. (SEE DETAILS)10. MANUFACTURERS' MODEL NUMBERS ARE SPECIFIED SOLELY TO ESTABLISHSTANDARDS OF QUALITY FOR PERFORMANCE AND MATERIALS.11. INSTALLATION SHALL ADHERE TO MANUFACTURERS' RECOMMENDATIONS.12. PROVIDE ACCESS PANELS TO SYSTEM COMPONENTS THAT ARECONCEALED AND REQUIRE PERIODIC SERVICE.13. TOPS OF ALL FLOOR DRAINS SHALL BE SET FLUSH WITH FINISHED FLOOR.ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED BY THEBUILDING STRUCTURE AND SHALL NOT REST ON CEILING STRUCTURE ORCOMPONENTS.14. ALL PLUMBING EQUIPMENT, PIPING, INSULATION, ETC., INSTALLED IN HVACPLENUM SPACES SHALL MEET CODE REQUIREMENTS FOR SMOKE ANDCOMBUSTIBILITY.15. PROVIDE SHUTOFF VALVES ON ALL BRANCH PIPING AND ON ALL SUPPLIESTO INDIVIDUAL FIXTURES AND EQUIPMENT. PROVIDE BALL VALVES ON ALLWATER MAIN BRANCHES IN CORRIDORS AND WHERE INDICATED ONDRAWINGS.16. PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS AND GUIDES ASNECESSARY TO PREVENT STRESS ON PIPING.17. PROVIDE VENTS AT HIGHT POINTS IN PIPING SYSTEMS AND DRAIN VALVESAT LOW POINTS.18. PROVIDE GAUGE FITTINGS AND THERMOMETER WELLS AT HOT WATERSUPPLY AND RETURN BRANCHES AND AT PUMP INLETS AND OUTLETS.19. PITCH PRESSURE PIPING IN DIRECTION OF FLOW.20. VERIFY EXACT SIZES, LOCATIONS, INVERTS AND ELEVATIONS PRIOR TORUNNING ANY PIPING. REFER TO ARCHITECTURAL DRAWINGS FOR EXACTLOCATIONS OF ALL FIXTURES AND EQUIPMENT. REFER TO KITCHEN LAYOUTDRAWING FOR EXACT LOCATION AND ROUGHT-IN REQUIREMENTS OF ALLKITCHEN FIXTURES AND EQUIPMENT.21. ALL WASTE PIPING FROM LAB SINKS & HOODS SHALL BE VALVED IN BASECABINET OF HOOD. NO CONNECTION TO LAB WASTE & LAB VENT PIPINGSYSTEM SHALL BE MADE.22. OBTAIN GAS PERMITS AND DEFRAY ALL COSTS INCIDENTAL TO THE GASPIPING SYSTEM. CONTRACTORS WORK SHALL COMMENCE ON THE HOUSESIDE OF THE UTILITY CO. METER.23. A SUITABLE DRIP OF CONDENSATE POCKET SHALL BE INSTALLED AT THEBOTTOM OF ALL GAS RISERS.24. ALL GAS PIPING TO COMPLY WITH LOCAL AND STATE CODES.25. GAS PIPING AND SAFETY DEVICES SHALL CONFORM TO THE REQUIREMENTSOF NFPA 54 AND SHALL BE SUBJECT TO THE INSPECTION AND APPROVAL OFTHE STATE REGULATORY BOARD.26. PROVIDE A SUITABLE GAS COCK VALVE AT EACH BRANCH RUNOUT FROMTHE MAIN RISER SERVING GAS OUTLETS AND AT EACH INDIVIDUAL GASFIXTURE.PLUMBING NOTES - NATURAL GAS1. OBTAIN GAS PERMITSONTRACTOR'S WORK SHALL COMMENCE ON THEHOUSE SIDE OF THE UTILITY CO. METER.2. A SUITABLE DRIP AND CONDENSATE POCKET SHALL BE INSTALLED AT THEBOTTOM OF ALL GAS RISERS.3. ALL GAS PIPING TO COMPLY WITH LOCAL AND STATE CODES.4. GAS PIPING AND SAFETY DEVICES SHALL CONFORM TO THE REQUIREMENTSOF NFPA 54 AND SHALL BE SUBJECT TO THE INSPECTION AND APPROVAL OFTHE STATE REGULATORY BOARD.5. PROVIDE A SUITABLE GAS COCK VALVE AT EACH BRANCH RUNOUT FROM THEMAIN RISER SERVICE GAS OUTLETS AND AT EACH INDIVIDUAL GAS FIXTURE.6. GAS PIPING SHALL BE TESTED ACCORDING TO THE STATE FUEL GAS CODEAND NATIONAL CODE PROVISIONS OF THE LOCAL PLUMBING INSPECTOR. IFINSPECTION OF THE TEST SHOWS DEFECTS, SUCH DEFECTIVE WORK ANDMATERIAL SHALL BE REPLACED AND INSPECTION AND TEST SHALL BEREDONE.7. PLUMBING CONTRACTOR IS RESPONSIBLE FOR EXTENDING ALL GAS TRAIN.8. WATER HEATERS SHALL BE INSTALLED WITH DRAIN PANS UNDER HEATERS.ROUTE PAN DRAINS TO NEAREST FLOOR DRAIN OR SAFE DRAIN.9. PIPING ENTERING SERVICE CORRIDOR FROM LAB AREAS SHALL NOT RUNOVER ELECTRICAL PANELS AND SHALL BE COORDINATED WITH WORK OFOTHER TRADES.PLUMBING ABBREVIATIONS - GENERALABB. ABBREVIATIONAC AIR CHAMBERAFF ABOVE FINISH FLOORAHJ AUTHORITY HAVING JURISDICTIONAP ACCESS PANELARCH ARCHITECTAVB ATMOSPHERIC VACUUM BREAKERBLDGBUILDINGBOP BOTTOM OF PIPEBOR BOTTOM OF RISERBVBALL VALVECFM CUBIC FEET PER MINUTECFS CUBIC FEET PER SECONDCICAST IRONCL CENTER LINECLDI CEMENT LINED DUCTILE IRONCLGCEILINGCOLCOLUMNCONT CONTINUATIONCP CHROME PLATEDCP-# HOT WATER CIRCULATING PUMP #CTE CONNECT TO EXISTINGCV CHECK VALVEDIADIAMETERDNDOWNDWGDRAWINGELELEVATIONEQEQUALETBR EXISTING TO BE REMOVEDETR EXISTING TO REMAINEWH ELECTRIC WATER HEATERFC FAIL CLOSEDFFE FINISH FLOOR ELEVATIONFOFAIL OPENFTFEETGALV GALVANIZEDGC GENERAL CONTRACTORGPD GALLONS PER DAYGPM GALLONS PER MINUTEGV GATE VALVEGWH GAS WATER HEATERHC HANDICAPPED ACCESSIBLEHP HORSEPOWERHZHERTZID INSIDE DIAMETERININCHESINVINVERTKWKILOWATTSMAXMAXIMUMMECH MECHANICALMEZZ MEZZANINEMFR MANUFACTURERMHMANHOLEMINMINIMUMMISC MISCELLANEOUSMTDMOUNTEDMV MIXING VALVEN/A NOT APPLICABLENC NORMALLY CLOSEDNIC NOT IN CONTRACTNO NORMALLY OPENNo.NUMBERNTS NOT TO SCALENUMNUMBEROCON CENTEROD OUTSIDE DIAMETER OR OVERFLOW DRAINOS&Y OUTSIDE SCREW & YOKEPC PLUMBING CONTRACTORPHPHASEPOS PROVIDED UNDER OTHER SECTIONPP POLYPROPYLENEPRV PRESSURE REDUCING VALVEPSI POUNDS PER SQUARE INCHPVB PRESSURE VACUUM BREAKERPVC POLYVINYL CHLORIDEQTYQUANTITYRCP REINFORCED CONCRETE PIPEREQ'D REQUIREDRPBP REDUCED PRESSURE BACKFLOW PREVENTORRPM REVOLUTIONS PER MINUTESCHSCHEDULESF SQUARE FOOTST.ST. STAINLESS STEELSWH STEAM WATER HEATERTOR TOP OF RISERTP TRAP PRIMERTYPTYPICALVIV VALVE IN VERTICALVTR VENT THROUGH THE ROOFW/WITHWHA WATER HAMMER ARRESTORWM WATER METERPLUMBING ABBREVIATIONS - DRAINAGEADAREA DRAINBWV BACK WATER VALVECICAST IRONCOCLEANOUTDDDECK DRAINDS DOWN SPOUT BOOTFCO FLOOR CLEANOUTFD FLOOR DRAINFMFORCE MAINFSFLOOR SINKGCO GRADE CLEANOUTGD GARAGE DRAINGI GREASE INTERCEPTORGT GREASE TRAPGV GARAGE VENTIW INDIRECT WASTEKW KITCHEN WASTELVLAB VENTLWLAB WASTEOD OVERFLOW ROOF DRAIN (SECONDARY)OED OPEN END DRAINPD PLANTER DRAIN W/ MESHSCREENRDROOF DRAINRWRAINWATERSANSANITARYSSSOIL STACKSSD SUB SOIL DRAINAGETD TRENCH DRAINVVENTVSVENT STACKWWASTEW & T WASTE & TRAPW & V WASTE & VENTWCO WALL CLEANOUTWS WASTE STACKPLUMBING ABBREVIATIONS - EQUIPMENTC CYLINDERCA COMPRESSED AIRCA-D COMPRESSED AIREWH TANKLESS WATER HEATERFCU MANIFOLDGEN N2LS LIFT STATIONM MANIFOLDN2 GENRO REVERSE OSMOSISTVAC VACUUMVP VACUUM PUMPPLUMBING ABBREVIATIONS - DOMESTIC WATER140F HW 140° HOT WATER SUPPLY140F HWR 140° HOT WATER RETURNCW COLD WATERHWHOT WATERHWR HOT WATER RETURNLCW LAB COLD WATERLHW LAB HOT WATERNPCW NON-POTABLE COLD WATERPWR PURE WATER RETURNPWS PURE WATER SUPPLYW WATER SERVICEPLUMBING ABBREVIATIONS - MATERIALCICAST IRONCLDI CEMENT LINED DUCTILE IRONGALV GALVANIZEDGWB GYPSUM WALL BOARDPP POLYPROPYLENEPVC POLYVINYL CHLORIDERCP REINFORCED CONCRETE PIPEST.ST STAINLESS STEELPLUMBING ABBREVIATIONS - GASESARARGONBA BREATHING AIRCA COMPRESSED AIRCA-# COMPRESSED AIR - #PSICAI COMPRESSED AIR INTAKECO2 CARBON DIOXIDEEOC EMERGENCY OXYGEN CONNECTIONEVAC MEDICAL GAS EVACUATIONG GAS (NATURAL)GAP GAS ALARM PANELGVC GAS VALVE CABINETH2HYDROGENHEHELIUMLGAP LOCAL GAS ALARM PANELMA MEDICAL AIRMGAP MASTER GAS ALARM PANELMGCV MEDICAL GAS CONTROL VALVEN2NITROGENN2-# NITROGEN - #PSIN2O NITROUS OXIDENCP NITROGEN CONTROL PANELO2OXYGENO3OZONEPPROPANEPAPATIENT AIRSP SPECIAL GASVACVACUUMVE VACUUM EXHAUSTVT VACUUM TRAPZVB ZONE VALVE BOXIN ACCORDANCE WITH THE FEDERAL SAFE WATER DRINKING ACT (SWDA) THE PLUMBING CONTRACTOR SHALL NOT INSTALL ANY COMPONENTS IN THE PLUMBING DOMESTIC WATER SYSTEM THAT CONTAINS MORE THAN 0.25% LEAD IN ANY OF ITS WETTED PARTS AFTER JANUARY 1ST, 2014. THE CONTRACTOR SHALL PROVIDE THE LEAD FREE EQUIVALENT OF THE MODEL NUMBERS LISTED IN THE PLANS AND SPECIFICATIONS FOR THESE COMPONENTSPLUMBING DEMO NOTES1. PROJECT CONDITIONSa. ALL WORK MUST BE COORDINATED W/ OWNER PRIOR TO ANYCOMMENCEMENT OF WORK.c. PROTECTION: ENSURE THE SAFE PASSAGE OF PERSONS IN AND AROUNDTHE BUILDING DURING DEMOLITION. PREVENT INJURY TO PERSONS ANDDAMAGE TO PROPERTY. PROVIDE ADEQUATE SHORING AND BRACING TOPREVENT COLLAPSE. IMMEDIATELY REPAIR DAMAGED PROPERTY TO THECONDITION BEFORE BEING DAMAGED. TAKE EFFECTIVE MEASURES TOPREVENT DUST MIGRATION.b. ITEMS OF VALUE WHICH ARE NOT INDICATED TO BE RETURNED TO THEOWNER, SHALL BECOME THE PROPERTY OF THE CONTRACTOR. STORAGEOR SALE OF ITEMS ON THE PROJECT SITE IS PROHIBITED.d. UTILITIES: MAINTAIN ALL UTILITIES EXCEPT THOSE REQUIRING REMOVAL ORRELOCATION. KEEP UTILITIES IN SERVICE AND PROTECT FROM DAMAGE. DONOT INTERRUPT UTILITIES SERVING USED AREAS WITHOUT FIRST OBTAININGPERMISSION FROM THE OWNER. PROVIDE TEMPORARY SERVICES ASREQUIRED. COORDINATE ALL WORK WITH OWNER.e. ALL WORK MUST BE COORDINATED W/ OWNER PRIOR TO ANYCOMMENCEMENT OF WORK.2. SCOPE OF WORKa. PERFORM WORK AND PROVIDE MATERIAL AND EQUIPMENT AS SHOWN ONDRAWINGS AND AS SPECIFIED IN THIS SECTION OF SPECIFICATIONS. GIVENOTICES, FILE PLANS, OBTAIN PERMITS FROM AUTHORITIES THAT HAVEJURISDICTION AS REQUIRED TO PERFORM WORK IN ACCORDANCE WITH ALLLEGAL REQUIREMENTS AND WITH SPECIFICATIONS AND DRAWINGS.3. REGULATORY REQUIREMENTSa. STRICTLY COMPLY WITH APPLICABLE CODES, REGULATIONS ANDREQUIREMENTS OF AUTHORITY HAVING JURISDICTION.4. HANDLING OF MATERIALSa. REMOVE ALL MATERIAL DEBRIS FROM THE SITE AS IT ACCUMULATES. DONOT STORE, SELL, BURN, OR OTHERWISE DISPOSE OF DEBRIS ON SITE.REMOVE ALL MATERIALS IN SUCH MANNER AS TO PREVENT SPILLAGE. KEEPALL PAVEMENTS AND AREAS ADJACENT TO AND LEADING FROM THE SITE,CLEAN AND FREE OF MUD, DIRT, AND DEBRIS AT ALL TIMES.5. TRANSFER OF RESPONSIBILITY AND DISPOSITION OF MATERIALSa. UPON RECEIPT OF NOTICE TO PROCEED WITH THE WORK, THE TITLE TO ALLMATERIALS FOR DEMOLITION SHALL BE VESTED IN THE CONTRACTORWHEREUPON THE OWNER WILL NOT BE RESPONSIBLE FOR THE CONDITION,LOSS, OR DAMAGE TO SAID PROPERTY. ALL SUCH ITEMS SHALL BEREMOVED FROM THE OWNER'S PROPERTY.6. CLEAN-UP AND REPAIRa. UPON COMPLETION OF DEMOLITION WORK, REMOVE TOOLS, EQUIPMENTAND DEMOLISHED MATERIALS FROM SITE. REMOVE PROTECTION AND LEAVEINTERIOR AREAS BROOM CLEAN.b. REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED. RETURNSTRUCTURES AND SURFACES TO EXISTING CONDITION PRIOR TOCOMMENCEMENT OF SELECTIVE DEMOLITION WORK. REPAIR ADJACENTCONSTRUCTION OR SURFACES SOILED OR DAMAGED BY SELECTIVEDEMOLITION WORK.# DATE DESCRIPTION1 11/30/18 ISSUED FOR CONSTRUCTION2 1/7/18 ADDENDUM 02222DocuSign Envelope ID: 495E9EAC-9F74-4159-ACA0-7B8831B044F51/4/2019