HomeMy WebLinkAboutM8.80HVAC - CONTROLSVFD VFD END OF MAIN BYPASS P-3 OUTDOOR AIR TEMPERATURE SENSOR - COMMON LPS TO HWS/R180 SYSTEMSYSTEM FROM HWS/R180 P-3A HX-1.1 HX-1.2 HWR HWSHWS180 HWS180 180 DEG. HW SYSTEM SERVES AHU PREHEAT AND PERIMETER HEAT LPC LPC DI DI DI DI DI DI DI AI AI AI AO DO AI AI DATA DATA DATA DATA DATA DATA DI DI DI DI DI DIDATA DATA DI DI DI DIDATA DIDATA DIDATA DATAZI ZI ZI ZI ZI ZI ZI GI 01 TT 02 TT 01 TT 03 ZI ZI ZI ZI ZI ZI ZI ZI ZI ZI ZI ZI CA-DD-1A CONTROL PANEL: TROUBLE ALARM & DATA DROP PURE WATER SYSTEM CONTROL PANEL: TROUBLE ALARM & DATA DROP CA-C-1A CONTROL PANEL: TROUBLE ALARM & DATA DROP REMOTE "TROUBLE ALARM" CONTACTS REMOTE "TROUBLE ALARM" CONTACTS PLUMBING SYSTEMS MONITOR/ALARMS VACUUM SYSTEM CONTROL PANEL: TROUBLE ALARM & DATA DROP SAFETY STATIONS: PROVIDE TROUBLE CONTACT WITH DISCRETE ADDRESS FOR EACH SAFETY EQUIPMENT CA-C-1B CONTROL PANEL: TROUBLE ALARM & DATA DROP CA-DD-1B CONTROL PANEL: TROUBLE ALARM & DATA DROP GENERAL 1. REFER TO SEQUENCE OF OPERATION - GENERAL, CONTROL SYSTEM NOTES AND SEQUENCE OF OPERATION - STANDBY POWER ON CONTROLS LEGEND SHEET M8.01 FOR ADDITIONAL REQUIREMENTS. 2. CONNECT TO EXISTING GAS DETECTION SYSTEM. ALARMS 1. THE FOLLOWING SHALL INITIATE SPECIFIC ALARM NOTICES AT THE BAS: a. CABINET SENSOR DETECTS GAS LEVELS ABOVE ACCEPTABLE LEVELS. AIRFLOW CONTROL 1. EXHAUST AIRFLOW SHALL NORMALLY BE CONSTANT VOLUME IF GAS DETECTION SYSTEM INDICATES UNACCEPTABLE LEVELS OF CONCENTRATION, AIRFLOW SHALL INCREASE TO PURGE AIRFLOW RATE DICTATED BY CABINET MANUFACTURER.. GENERAL 1. HEATING SYSTEM SHALL BE OPERATIONAL 24 HOURS PER DAY, 7 DAYS PER WEEK. 2. REFER TO SEQUENCE OF OPERATION - GENERAL, CONTROL SYSTEM NOTES AND SEQUENCE OF OPERATION - STANDBY POWER ON CONTROLS LEGEND SHEET M8.01 FOR ADDITIONAL REQUIREMENTS. 3. EXISTING RE-HEAT LOOP IS BEING MODIFIED TO ADD CAPACITY FOR THIS PROJECT. EXISTING LOOP HAS 1 HEAT EXCHANGER AND 1 PUMP. THIS PROJECT IS ADDING 1 HEAT EXCHANGER AND 1 PUMP. ASSOCIATED CONTROL POINTS FOR NEW EQUIPMENT SHALL BE PROVIDED. EXISTING TO REMAIN COMPONENTS ARE LISTED. SAFETIES 1. THE FOLLOWING SAFETIES, EACH WITH INDIVIDUAL MANUAL RESETS, SHALL SHUT DOWN EXHAUST FAN(S) AND INITIATE A SPECIFIC ALARM NOTICE AT THE BAS: a. DIFFERENTIAL PRESSURE AT PDT-01 INDICATES PUMP IS IN DEADHEAD CONDITION. DEADHEAD SETPOINT SHALL BE DETERMINED FROM APPROVED SHOP DRAWING PUMP CURVE. ALARMS 1. THE FOLLOWING SHALL INITIATE SPECIFIC ALARM NOTICES AT THE BAS ONLY WHEN THE UNIT IS STATUS ON: a. ANY PUMP IS COMMANDED TO RUN AND THE BAS SENSES NO STATUS AT CURRENT TRANSMITTER CONTINUOUSLY FOR 10 SECONDS. b. SUPPLY HOT WATER IS AT LEAST 10°F ABOVE OR BELOW SETPOINT CONTINUOUSLY FOR 30 SECONDS. ACTIVE/STANDBY DESIGNATION 1. EVERY WEEK, THE BAS WILL SWITCH THE STANDBY/ACTIVE HEAT EXCHANGER DESIGNATIONS AND THE FOLLOWING SHALL OCCUR: a. NEWLY ACTIVE HEAT EXCHANGER HOT WATER ISOLATION VALVE SHALL FULLY OPEN. b. AFTER HOT WATER VALVE IS OPEN, NEWLY ACTIVE HEAT EXCHANGER STEAM CONTROL VALVES SHALL MODULATE IN ACCORDANCE WITH TEMPERATURE CONTROL PARAGRAPH BELOW. c. AFTER A 30 SECOND DELAY, PREVIOUSLY ACTIVE HEAT EXCHANGER STEAM CONTROL VALVES AND HOT WATER ISOLATION VALVE SHALL FULLY CLOSE. 2. EVERY WEEK, THE BAS WILL SWITCH THE STANDBY/ACTIVE PUMP DESIGNATIONS. TEMPERATURE CONTROL 1. EXISTING SUPPLY TEMPERATURE CONTROL SHALL REMAIN. MODIFICATIONS SHALL ONLY BE DONE TO ADD NEW COMPONENTS TO SYSTEM WITHOUT EFFECTING SYSTEM PERFORMANCE. 2. IF TEMPERATURE IS BELOW SETPOINT AND STEAM CONTROL VALVE IS FULLY OPEN ON ACTIVE HEAT EXCHANGERS, BOTH HEAT EXCHANGERS SHALL OPERATE TO MAINTAIN HYDRONIC TEMPERATURE. PUMP SPEED CONTROL 1. ACTIVE PUMP VFD SHALL MODULATE TO MAINTAIN STATIC PRESSURE SETPOINT AT EXISTING SENSOR. 2. THE INITIAL DIFFERENTIAL PRESSURE SETPOINT SHALL BE 15 PSI. THIS VALUE SHALL BE ADJUSTED TO THE REQUIRED SETPOINT TO ACHIEVE THE PROPER FLOW RATE AS DETERMINED DURING BALANCING. 3. IF VFD OF OPERATING PUMP IS AT MAXIMUM SPEED AND PRESSURE SETPOINT IS NOT MAINTAINED, BOTH PUMPS SHALL RUN TO MAINTAIN SYSTEM PRESSURE. BACNET DATA DROP CONNECTION CA-F-1A: REMOTE TROUBLE ALARM CA-F-1B: REMOTE TROUBLE ALARM CA-F-2A: REMOTE TROUBLE ALARM CA-F-2B: REMOTE TROUBLE ALARM SAN-SP-1A CONTROL PANEL: TROUBLE ALARM & DATA DROP SAN-SP-1B CONTROL PANEL: TROUBLE ALARM & DATA DROP CA-DEWPOINT ANALYZER: LOOP POWERED W/ DATA DROP 4-20 AMP LHWR-CP-1: REMOTE TROUBLE ALARM N2-OXYGEN ANALYZER: LOOP POWERED W/ DATA DROP 4-20 AMP N2-PRESSURE TRANSMITTER: LOOP POWERED W/ DATA DROP 4-20 AMP N2-FLOW METER : LOOP POWERED W/ DATA DROP 4-20 AMP LHWR-EWH-1: REMOTE TROUBLE ALARM BACNET DATA DROP CONNECTION REMOTE "TROUBLE ALARM" CONTACTS GAS CABINET CO SENSOR GAS CABINET EXHAUST VALVE RE-HEAT HOT WATER SYSTEM CONTROLS TYPICAL FOR EACH HEAT EXCHANGER (XM) (XM) (XM) (XM) (XM) (XM) (XM) (XM) CYLINDER STORAGE GAS DETECTION TCV 01 PDT 01 LEAD HX LAG HX FCV 01 2 Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 NTS M8.80 29313.00 11/30/18 HVAC - CONTROLS # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION 2 1/7/18 ADDENDUM 02 DocuSign Envelope ID: 495E9EAC-9F74-4159-ACA0-7B8831B044F5 1/4/2019