HomeMy WebLinkAboutM8.40HVAC - CONTROLSFM C C CCECM C C C ECM T DI AO DI AI AO AI AO AO DO AO AI AI AO AI AI AI C CC ZS 01 FCV 01 MI 01 FT 01 FCD 01 TT 01 FCV 01 FCV 01 MI 01 FCV 01 ZI 01 FT 01 FCD 01 ZI 01 TT 01 TT 01 HEAT EXCHANGERS HEAT RECOVERY LPC FROM STEAM CONDENSATE ENERGY METER ENERGY METERS AND ENERGY REPORTING GENERAL 1. REFER TO SEQUENCE OF OPERATION - GENERAL, CONTROL SYSTEM NOTES AND SEQUENCE OF OPERATION - STANDBY POWER ON CONTROLS LEGEND SHEET M8.01 FOR ADDITIONAL REQUIREMENTS. SYSTEM OPERATION 1. ENERGY METER SHALL BE DIRECTLY CONNECTED TO, AND THE DATA SHALL BE DIRECTLY INSTALLED IN THE BUILDING AUTOMATION SYSTEM. 2. STEAM CONDENSATE (BTU), AND ELECTRIC (KW) SHALL BE MONITORED. FIRE SMOKE DAMPER CONTROLS. GENERAL 1. REFER TO SEQUENCE OF OPERATION - GENERAL, CONTROL SYSTEM NOTES AND SEQUENCE OF OPERATION - STANDBY POWER ON CONTROLS LEGEND SHEET M8.01 FOR ADDITIONAL REQUIREMENTS. SYSTEM OPERATION 1. REFER TO FIRE ALARM PLANS FOR DAMPER CONTROL. SMOKE DETECTION AND FIRE-SMOKE DAMPER ACTIVATION BY DIVISION 28 SMOKE DETECTION MONITORING OF FIRE/SMOIKE DAMPER POSITION / END SWITCH BY DIVISION 23 GENERAL 1. REQUIREMENTS OF "SEQUENCE OF OPERATION - GENERAL" ON DRAWING M8.10 APPLY TO ALL SEQUENCES. 2. REFER TO ZONE CONTROL SEQUENCES FOR ADDITIONAL POINTS AND REQUIREMENTS. TEMPERATURE CONTROL 1. UNLESS STATED OTHERWISE BY ZONE CONTROL SEQUENCES, FCU SHALL MODULATE CHILLED WATER VALVE AND FAN SPEED TO MAINTAIN SPACE TEMPERATURE SETPOINT. IF TEMPERATURE IS AT LEAST 5 DEG F ABOVE SETPOINT, ALARM SHALL BE SENT TO BAS. SAFETIES 1. THE FOLLOWING SAFETIES, EACH WITH INDIVIDUAL MANUAL RESETS, SHALL SHUT DOWN FCU AND INITIATE A SPECIFIC ALARM NOTICE AT THE BAS: a. MOISTURE SENSOR MI-01 INDICATES WATER IN SECONDARY DRAIN PAN. GENERAL 1. REFER TO SEQUENCE OF OPERATION - GENERAL, CONTROL SYSTEM NOTES AND SEQUENCE OF OPERATION - STANDBY POWER ON CONTROLS LEGEND SHEET M8.01 FOR ADDITIONAL REQUIREMENTS. 2. LAB SUPPLY TERMINAL BOXES (SV) WILL HAVE SEPARATE HEATING COILS. OFFICE SUPPLY TERMINAL BOXES (VV) WILL HAVE INTEGRAL HEATING COILS. ARRANGEMENT OF POINTS AND CONTROL WILL BE THE SAME FOR BOTH OF THESE DEVICES. 3. REFER TO ZONE CONTROL SEQUENCES FOR ADDITIONAL POINTS AND REQUIREMENTS. ALARMS 1. THE FOLLOWING SHALL INITIATE SPECIFIC ALARM NOTICES AT THE BAS ONLY WHEN THE UNIT IS STATUS ON: a. AIRFLOW RATE RISES 10% ABOVE SETPOINT CONTINUOUSLY FOR 5 MINUTES. b. AIRFLOW RATE DROPS 10% BELOW SETPOINT CONTINUOUSLY FOR 5 MINUTES. c. INTERNAL CONTROLLER INDICATES ALARM. AIRFLOW CONTROL 1. SUPPLY AIRFLOW SHALL BE MEASURED AT INLET FLOW MEASUREMENT DEVICE AND ADJUSTED BY MODULATING THE AIRFLOW CONTROL DEVICE TO MAINTAIN SUPPLY AIRFLOW SETPOINT. 2. AIRFLOW FEEDBACK WILL BE PROVIDED FROM VALVES TO BMS. GENERAL 1. REFER TO SEQUENCE OF OPERATION - GENERAL, CONTROL SYSTEM NOTES AND SEQUENCE OF OPERATION - STANDBY POWER ON CONTROLS LEGEND SHEET M8.01 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ZONE CONTROL SEQUENCES FOR ADDITIONAL POINTS AND REQUIREMENTS. ALARMS 1. THE FOLLOWING SHALL INITIATE SPECIFIC ALARM NOTICES AT THE BAS ONLY WHEN THE UNIT IS STATUS ON: a. AIRFLOW RATE RISES 10% ABOVE SETPOINT CONTINUOUSLY FOR 5 MINUTES. b. AIRFLOW RATE DROPS 10% BELOW SETPOINT CONTINUOUSLY FOR 5 MINUTES. c. INTERNAL CONTROLLER INDICATES ALARM. AIRFLOW CONTROL 1. EXHAUST AIRFLOW SHALL BE MEASURED AT INLET FLOW MEASUREMENT DEVICE AND ADJUSTED BY MODULATING THE AIRFLOW CONTROL DEVICE TO MAINTAIN EXHAUST AIRFLOW SETPOINT. 2. AIRFLOW FEEDBACK WILL BE PROVIDED FROM VALVES TO BMS. GENERAL 1. REQUIREMENTS OF "SEQUENCE OF OPERATION - GENERAL" ON DRAWING M8.10 APPLY TO ALL SEQUENCES. 2. REFER TO ZONE CONTROL SEQUENCES FOR ADDITIONAL POINTS AND REQUIREMENTS. SAFETIES 1. THE FOLLOWING SAFETIES, EACH WITH INDIVIDUAL MANUAL RESETS, SHALL SHUT DOWN CHILLED BEAM CONTROL VALVE FCV-01 AND INITIATE A SPECIFIC ALARM NOTICE AT THE BAS: a. MOISTURE SENSOR MI-01 INDICATES CONDENSATION ON CHILLED WATER PIPE. TO EXISTING CONDENSATE PUMP GENERAL 1. REQUIREMENTS OF "SEQUENCE OF OPERATION - GENERAL" ON DRAWING M8.10 APPLY TO ALL SEQUENCES. 2. REFER TO ZONE CONTROL SEQUENCES FOR ADDITIONAL POINTS AND REQUIREMENTS. TEMPERATURE CONTROL 1. UNLESS STATED OTHERWISE BY ZONE CONTROL SEQUENCES, FCU SHALL MODULATE CHILLED WATER VALVE AND FAN SPEED TO MAINTAIN SPACE TEMPERATURE SETPOINT. IF TEMPERATURE IS AT LEAST 5 DEG F ABOVE SETPOINT, ALARM SHALL BE SENT TO BAS. 2. FIRE/SMOKE ISOLATION DAMPER BY DIVISION 23 AIR OUTLETAIR INLET FAN COIL UNIT CHWR CHWS SECONDARY DRAIN PAN WITH LEAK DETECTOR HEATING COIL SUPPLY AIR VALVE AIR OUTLETAIR INLET HWS HWR INDUCED ROOM AIR PRIMARY AIR FROM AHU DISCHARGE AIR CHWS CHWR TO ADDITIONAL CHILLED BEAMS IN ZONE AIR OUTLETAIR INLET FAN COIL UNIT CHWR CHWS EXHAUST AIR VALVE AIR OUTLETAIR INLET ANALOG-ELECTRIC CONTROLER ANALOG-ELECTRIC CONTROLER 2 PIPE FAN COIL UNIT IN BASEMENT MECH RM CONTROLS TYPICAL SUPPLY AIR VALVE CONTROL DETAIL TYPICAL EXHAUST AIR TERMINAL BOX (VVE AND EV) CONTROL DETAIL ACTIVE CHILLED BEAM CONTROLS SENSIBLE ONLY 2 PIPE FAN COIL UNIT CONTROLS RH 2 Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 NTS M8.40 29313.00 11/30/18 HVAC - CONTROLS # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION 2 1/7/18 ADDENDUM 02 DocuSign Envelope ID: 495E9EAC-9F74-4159-ACA0-7B8831B044F5 1/4/2019