HomeMy WebLinkAboutM5.50HVAC - DETAILSSCALE: SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: DRAW THROUGH UNIT CONDENSATE TRAP9 N.T.S. ROOF PIPING SUPPORT5 NTS DETAIL OF PIPE THRU ROOF (EXCLUDING STEAM RELIEFS)3 NTS PIPE RISER SUPPORT6 NTS PIPE PENETRATION OF FULL HEIGHT PARTITIONS7 NTS TYPICAL PIPE INSULATION & VALVE HANDLE EXTENSION11 NTS TYPICAL FREEZESTAT LAYOUTS FOR AHU COOLING COILS1 NTSSCALE: SCALE: SCALE: PITCH 1" WATER SEAL. WC (WITH DIRTY FILTERS, COILS, GREATER THAN THE MAXIMUM FAN THIS DIMENSION IN INCHES MUST BE SUCTION STATIC PRESSURE IN INCHES AND MAXIMUM AIR FLOW). MAXIMUM FAN SUCTION STATIC GREATER THAN 1/2 OF THE SAME THIS DIMENSION IN INCHES MUST BE PRESSURE IN INCHES WC. DRAIN PAN NOTES:1. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP. 2. PITCH DRAIN FOR PROPER RUNOFF. 3. MANUALLY PRIME FILL TRAP BEFORE START-UP TO FORM INITIAL DRAIN SEAL. 4. SUPPORT LENGTHY DRAIN LINES TO PREVENT SAG AND CONDENSATE OVERFLOW. PITCH DRAIN PIPE TO MATCH DRAIN OUTLET SIZE. CLEANOUT (TYP.) (a) (c) (b) (a) (b) (c) 3" 1.5" 1" AND ACCEPTANCE BY ROOFING CONTRACTOR. REGISTERED STRUCTURAL ENGINEER. 4. THE SUPPORTS SHALL BE SUBMITTED AS SHOP DRAWINGS AND SHALL BE REVIEWED BY THE 18" MAX. SEE NOTE 1 W 3. FOR DISTANCE BETWEEN SUPPORTS REFER TO SPECIFICATIONS. CENTER SUPPORTPLATE SEE NOTE 2 AVOID ROOF MEMBRANE DAMAGE. OBTAIN WRITTEN, APPROVED DRAWINGS OF COORDINATION 2. SIZE PLATE SUFFICIENT TO AVOID ROOF DAMAGE, BUT NO LESS THAN 8"x8". BRAKE EDGES TO 1. FOR W >= 24" AND PIPES >= 6" PROVIDE 3/4"∅ CENTER SUPPORT WITH NUT AND NUT LOCK. NOTES: SADDLE COVERING PROTECTION ROLLER SUPPORT WITH 5.4 #/FT AND TO PLATE ROOF TO C-SECTION 2" PIPE WELDED 4" C-SECTION; WELD 5" MIN. 2" MIN. 1/4" MIN 1" OR OTHER APPROVED MATERIAL FIREPROOF MINERAL WOOL SCHEDULE 80 PIPE ONE SIZE LARGER THAN RISER SLEEVE ONE NOMINAL THAN SLEEVE NOMINAL SIZE LARGER RISER CLAMP CONTINUOUS WELD FIREPROOF CAULK (TOP & BOTTOM) FLASHING POS COUNTER ROOF BUILT UP PIPE SLEEVE AROUND ALL SEAL DRAWINGS SEE ARCHITECTS ROOF CONSTRUCTION FLASHING POS 16 OUNCE COPPER JOSAM #26450 SIMILAR TO FLASHING SLEEVE FOR SIZE PIPING SEE PLANS NOTES: 1. AT FIRE RATED PARTITIONS, REPLACE PACKING AND SILICONE SEALANT WITH UL LISTED FIRE STOP SYSTEM. INSTALL IN ACCORDANCE WITH UL LISTING. 2. FIRE STOP PIPE PENETRATIONS THRU CORRIDOR WALLS ABOVE CEILINGS. MINERAL FIBER PACKING PIPE SLEEVE 1/2" MAX (TYP) SILICONE ACOUSTICAL AND AIRFLOW SEALANT NON-RATED PARTITION BUTT & SEAL JOINTS CAP INSULATION. LEAVE NO EXPOSED INSULATION ANYWHERE PROVIDE VALVE EXTENSION KIT TO ALLOW PROPER INSULATION COVERAGE END CAP ALUMINUM CROSSBRACE 180° CORNER SECTION NON-HARDENING HEAT PASTE BETWEEN TUBING & ALUMINUM INSULATION BY DIV 23 HANGING DEVICE SCALE: RADIANT PANEL INSTALLATION DETAILS8 NONE OF FREEZESTAT REFER TO SPEC. FOR LENGTH FZ FZFZ FZ COOLING COIL (TYP) PREFABRICATED EQUIPMENT SUPPORT. EXTERIOR DUCTWORK SUPPORT AND INSULATION1 NTS ROOF ANCHOR CURB TO DECK IN ACCORDANCE WITH CURB MANUFACTURER INSTRUCTIONS A A ROOFING INSULATION ROOFING MEMBRANE WOOD BLOCKING ALUMINUM METAL CAP S.S. BOLT 6x6x3/8 GALV. PLATES SUPPORT 8" WIDE CONTINUOUS GALVANIZED SHEET METAL SADDLE RIGID EXTRUDED BOARD WITH FOIL FACE 6" OVERLAP MIN. VENTURECLAD VAPOR BARRIER JACKETING SYSTEM. PITCH DN SECTION A-A UNISTRUT DUCTWORK SUPPORT W/ ADJUSTABLE HEIGHT FIRST VAPOR JACKET SEAM SHALL BE A MIN. OF 12 INCHES FROM THE SADDLE SUPPORT (BOTH SIDES) INSULATION PIN AS RECOMMENDED BY MANUFACTURE DUCT BASE BOARD THICKNESS TO MATCH EXISTING 6lb DENSITY RIGID FIBER BOARD INSULATION 8" WIDTH GALVANIZED SHEET METAL SADDLE SADDLE TO BE DE-BURRED TO AVOID DAMAGE TO THE VAPOR BARRIER JACKETED ASSEMBLY 8" DUCT PENETRATION THROUGH ROOF2 NTS PREFABRICATED, INSULATED CURB WITH WOOD NAILOR (THYCURB OR EQUAL) COMPLETELY SEAL & COVER JOINT WITH OUTDOOR, UV RESISTANT SEALANT SS SHEETMETAL SCREW S-SLIP CONNECTION FLASHING ROOF MEMBRANE ROOF DECK INSULATION ANCHOR CURB TO DECK CONCRETE DECK STEEL DECK TACK WELD CURB TO DECK DUCT PENETRATION OF FULL HEIGHT PARTITIONS10 NTS STEEL FRAME, ANGLE 1.25"X1.25"X0.125" ONLY AT PENETRATIONS EXPOSED TO VIEW IN NON-MECHANICAL OR ELECTRICAL SPACES SILICONE ACOUSTICAL AND AIRFLOW SEALANT (TYP) FRAMED OPENING OR SHEETMETAL SLEEVE SHEETMETAL SLEEVE MINERAL FIBER PACKING SILICONE ACOUSTICAL AND AIRFLOW SEALANT (TYP) NON-RATED PARTITION 1/2" MAX (TYP) 1/2" MAX (TYP) NON-RATED PARTITION NOTES: 1. AT FIRE RATED PARTITIONS WITHOUT FIRE DAMPER, REPLACE PACKING AND SILICONE SEALANT WITH UL LISTED FIRE STOP SYSTEM. INSTALL IN ACCORDANCE WITH UL LISTING. 2. FIRE STOP DUCT PENETRATIONS THRU RATED AND NON-RATED CORRIDOR WALLS ABOVE CEILINGS. NOTES: 1. INSTALLATION SHALL BE IN FULL COMPLIANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2 Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 NTS M5.50 29313.00 11/30/18 HVAC - DETAILS # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION 2 1/7/18 ADDENDUM 02 DocuSign Envelope ID: 495E9EAC-9F74-4159-ACA0-7B8831B044F5 1/4/2019