Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M2.30HVAC - LEVEL 3
21 3 4 6 7 8 5 Q P R S T O U 9 S1 R1 4A Q1 5.1 E 1 S 1 E 2 KEY NOTES: EXISITING CHILLED BEAMS TO BE RELOCATED TO WRITE-UP SPACE. REFERENCE DEMO DWGS M1.20 & M1.30 FOR EXISTING LOCATION. REFER TO SCHEDULES FOR BALANCING INFORMATION. ALL EXPOSED DUCT MAINS ARE TO BE ROUND OR OVAL DOUBLE WALL CONSTRUCTION. RELOCATE EXISTING SUPPLY AND RETURN CLASSROOM DUCTWORK THAT CURRENTLY RUNS THROUGH PHASE 1 SPACES. RELOCATED DUCTWORK SHOWN BELOW, COORDINATE SHUTDOWN WITH OWNER. 12" ROUND EXHUAST DUCT DROP FOR CONNECTION TO 6' FUME HOOD. 12" ROUND EXHUAST DUCT DROP FOR CONNECTION TO 4' FUME HOOD. INSTALL FIRESTOP AT ALL EXISTING HAVC PIPING FLOOR PENETRATIONS. 3RD FLOOR SLAB WILL BECOME 1-HR RATED IN FUTURE CONSTRUCTION PHASE. 10" ROUND EXHAUST DUCT DROP FOR 340CFM VENTILATED ENCLOSURE. 8" ROUND EXHAUST DUCT DROP FOR CONNECTION TO GAS CABINET (200 CFM). RECONNECT ALL EXISTING CHILLED BEAM BRANCH PIPING TO RELOCATED MAIN. EXISTING VALVES AND PIPING ACCESSORIES SHALL REMAIN. RE-BALANCE EXISTING SUPPLY DIFFUSERS ON THIS DUCT RUN TO PRE-BALANCE READINGS AND RE-PROGRAM CSV-352 TO OPERATE AT 1,730 CFM (100 CFM HIGHER THAN RECORD SCHEDULE) 1 2 3 SFD (14' - 4") RCP 1.1 (15' - 2") RCP 1.1 (6' - 9") RCP 1.1 (7' - 5") RCP 1.1 (7' - 1") RCP 1.1 (18' - 6") RCP 1.1 (6' - 5") RCP 1.1 (XM)3" CBS&R DN FCU 3 (XR)CB 362-2 4 1 RESEARCH LAB 367 LIGHT SCATTERING 367B ? ? ? SUPPORT 1 367D LAB WRITE-UP 362 E-BEAM DEPOSITION ROOM 367F LAB EQUIPMENT 367E SUPPORT 2 367C FLUORESCENCE MICROSCOPE 367A ? ? ? STAIRS 300SA Room 352 Room 354 Room 356 PURE WATER CLOSET 300JA ELECTRICAL 300UA PLUMBING 300UB Room 358 CONFERENCE ROOM 360 (17' - 1") RCP 1.1 (17' - 1") RCP 1.1 (7' - 3") RCP 1.1 (11' - 8") RCP 1.1 EV 3.4 EV 3.3 EV 3.2 EV 3.8 EV 3.9 EV 3.10 EV 3.13 EV 3.14 SV 3.1 SV 3.2 SV 3.3 SV 3.9 SV 3.8 28"ø 22"ø 12"ø24"x20"10"ø10"ø14"x32"24"x20"36"x20"18"ø12"ø42"x24" 20"x24" 24"ø 10"x10"18"x10"12"x15"T T T T T 2 2 2 2 3 3 3 3 3 3 5 6 44 4 4 5 36"x20"30"ø 24"x20"GENERAL NOTES: 1. DUCTWORK AND PIPING SUPPORT IN THE OPEN LABS SHALL BE COORDINATED WITH THE COMMON SUPPORT SYSTEM. REFER TO ARCHITECT PLANS FOR DETAILS.36"x20"EV 3.1 EV 3.11 EV 3.12 SV 3.4 SV 3.5 SV 3.7 SV 3.6 A2(310) A2(270) C2(410)C3(370) FD FD 8"ø C5(1150) A3(580)A3(580) C4(950) B2 (1500)B2 (1500)B2 (1000) C5(1150) A3(580) E4(1350)A3(610) A3(610) A3(610) EV 3.7 EV 3.15 EV 3.16 P P 13' - 6"14' - 6"7' - 6" (XM)PASSIVE CHILLED BEAM (TYP) (XM)FD 7 6 6 T16"ø14"ø (XM)FD FD 48"x24"42"x24"1 (XM)CB-360-2 12"x8" WMS AT TRANSFER DUCT PENETRATION ABOVE CEILING (TYP.) WMS AT TRANSFER DUCT PENETRATION ABOVE CEILING C3 (-) FD 12"x8"F2(220) 3" CBWS 3" CBWR 1 1/2" PHWS 1 1/2" PHWR12"ø1 1/2" HWR 1 1/2" HWS 1" HWR 1" HWS 10"ø1" PHWS F1(60)F1(60)F1(60)F1(60) 8 7 7 8 9 99 9 99999 GW 1 RHW 1 1 1/2" HWR 1 1/2" HWS 1 1/2" PHWS 1 1/2" PHWR FD 42"x24" 42"x18" (XM)FD 12"x12"(XR)CB 360-1 (XR)CB 361-1 (XR)CB 375-1 (XR)CB 375-2 (XR)CB 377-1 (XR)CB 362-1 F2(305) 10 10 T FD 1 (XN)VSV-365G 305/305 50 PROVIDE 12" ROUND DUCT DROP CAP FOR FUTURE FUME HOOD CONNECTION SCOPE OF WORK FCU 5 A1(100) FD 10"x10"18"ø18"ø 18"ø KEY NOTES (CONTINUED): RADIANT PANEL HEIGHT SHALL MATCH HEIGHT OF ADJACENT UTILITY SUPPORT SYSTEM. RADIANT PANEL SHALL BE INSTALLED AT THE TOP OF THE WINDOW, RIGHT BELOW THE HEADER. RADIANT PANEL SHALL BE INSTALLED IN THE CEILING ABOVE THE WINDOW. 11 12 3 11 3 11 3 11 3 11 3 13 3 13 3 13 3 13 3 12 3 12 3 123 13 (8' - 8") RCP 1.1 12 3 Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 1/4" = 1'-0" M2.30 29313.00 11/30/18 HVAC - LEVEL 3 # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION 2 12/18/18 ADDENDUM 01 3 1/7/18 ADDENDUM 02 DocuSign Envelope ID: 495E9EAC-9F74-4159-ACA0-7B8831B044F5 1/4/2019