Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M1.30HVAC - LEVEL 3 DEMO
21 3 4 6 7 8 5 Q P R S T O U 9 S1 R1 4A Q1 5.1 (X)1-1/4" RHWR DN (X)1-1/4" RHWS DN (XM)3" CBS&R DN KEY NOTES: EXISTING CHILLED BEAM TO BE RE-USED IN WRITE UP SPACE. REFER TO NEW WORK PLAN FOR LOCATION. CLEAN AND PROTECT BEFORE RE-USE. TYPICAL CHILLED BEAM PIPING SUPPLY AND RETURN EXAMPLE SHOWN FOR DRAWING CLARITY. ALL CHILLED BEAM ASSOCIATED PIPING WITHIN PHASE 1 SCOPE TO BE REMOVED. WITHIN THE SCOPE OF WORK, DEMOLISH ALL EXISTING PERIMETER RADIATORS AND ASSOCIATED PIPING. ALL PERIMTER RADIATORS OUTSIDE OF SCOPE OF WORK SHALL REMAIN OPPERATIONAL. 1 2 2 2 (X)1-1/4" CBS (X)1-1/4" CBR (X)1-1/4" CBS&R (XR)CB-375-2 (X)CHILLED BEAM (TYP) (X)CHILLED BEAM (TYP) (XM)8"x4" (X)8"x6" (X)8"x6" (XM)2-1/2" CBS&R (XR) 48"x18" (XR) 48"x24" (X)8"x4" (X)8"x6" (XR)VSV-365G (X)6"x4" (XR)12"x15" (X)CB-365-1 (X)CB-379-1 (X)CB-379-1 ? ? ?? ? ? (X)16"x10"(X)11"x16"(X)10"x10"(X)10"x8" (X)8"x6" (XR) 48"x24" Room 365A Room 365D Room 355 Room 365E Room 365C Room 361 Room 365F Room 358 Room 300CD Room 378 Room 360 Room 300SA Room 375 Room 362 Room 377 Room 352 Room 354 Room 356 Room 365 Room 379 Room 365G Room 300JA Room 300UA Room 300UB (XM)CHILLED BEAM (TYP) (XM)CHILLED BEAM (TYP) (XM)FD (XM)FD (XM)CB-360-2 (XM)FD 1 (XR)CB-375-11 (XR)CB-377-11 (XR)CB-362-11 (XR)CB-362-21 (XR)CB-361-11 (XR)CB-360-11 SCOPE OF WORK 2 3 (X)RADIANT PANEL (TYP)3 2 222222 2 2 2 2 2 2 2 2 2 2 Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 1/4" = 1'-0" M1.30 29313.00 11/30/18 HVAC - LEVEL 3 DEMO # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION 2 1/7/18 ADDENDUM 02 DocuSign Envelope ID: 495E9EAC-9F74-4159-ACA0-7B8831B044F5 1/4/2019