Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FP0.01FIRE PROTECTION SYMBOLS & ABBREVIATIONS
FDCTHFDHARzdwgxdwgydwgRISER DESIGNATIONDRAWING NUMBERrdwgSYMBOLS - GENERAL ANNOTATIONSECTION NUMBERCONNECT TO EXISTINGDRAWING NUMBERELEVATION NUMBERDRAWING NUMBERDETAIL / PART-PLAN NUMBERDRAWING NUMBERKEY NOTE##HYDRAULIC CALCULATION NODESINGLE-LINE SYMBOLS - VALVES AND PIPE ACCESSORIESINDICATING ISOLATION VALVECHECK VALVEINDICATING PRESSURE REGULATING ISOLATION VALVENON-INDICATING (DRAIN) VALVEPILOT OPERATED PRESSURE CONTROL VALVEPILOT OPERATED PRESSURE RELIEF VALVEPOST INDICATING ISOLATION VALVESINGLE-LINE SYMBOLS - RISER AND ALARM CHECK VALVESWET-PIPE RISER CHECK VALVEWET-PIPE ALARM CHECK VALVEDRY-PIPE ALARM CHECK VALVEPREACTION ALARM CHECK VALVEDELUGE ALARM CHECK VALVESINGLE-LINE SYMBOLS - BACKFLOW PREVENTERSBACKFLOW PREVENTER - DOUBLE CHECK VALVE ASSEMBLYBACKFLOW PREVENTER - REDUCED PRESSURE ZONE ASSEMBLYSINGLE-LINE SYMBOLS - FIRE HOSE VALVESFIRE HOSE VALVEFIRE HOSE VALVE AND HOSE REELFIRE HOSE VALVE CABINETFIRE HOSE VALVE / HOSE REEL CABINETFIRE HOSE VALVE - PRESSURE REGULATING TYPESINGLE-LINE SYMBOLS - CONNECTIONSFIRE DEPARTMENT INLET CONNECTIONFIRE DEPARTMENT OUTLET HYDRANT CONNECTIONFIRE PUMP TEST HEADER CONNECTIONSYMBOLS - SPRINKLERS AND NOZZLESPENDENT FRAME STANDARD SPRAY PATTERN SPRINKLERTEST AND DRAIN VALVEWET SYSTEM AIR RELEASE VENTPRESSURE RELIEF VALVE (SPRING OPERATED)UPRIGHT FRAME STANDARD SPRAY PATTERN SPRINKLERSIDEWALL FRAME STANDARD SPRAY PATTERN SPRINKLERPENDENT FRAME EXTENDED COVERAGE SPRAY PATTERN SPRINKLERUPRIGHT FRAME EXTENDED COVERAGE SPRAY PATTERN SPRINKLERSIDEWALL FRAME EXTENDED COVERAGE SPRAY PATTERN SPRINKLERPENDENT FRAME ESFR SPRINKLERUPRIGHT FRAME ESFR SPRINKLERPENDENT FRAME CMSA STORAGE PROTECTION SPRINKLERUPRIGHT FRAME CMSA STORAGE PROTECTION SPRINKLERPENDENT-VERTICAL SIDEWALL FRAME NRTL LISTED WINDOW SPRINKLERHORIZONTAL SIDEWALL FRAME NRTL LISTED WINDOW SPRINKLERUPRIGHT FRAME NRTL LISTED ATTIC SPRINKLERUPRIGHT FRAME NRTL LISTED COMBUSTIBLE CONCEALED SPACESPRINKLER360-DEGREE DISCHARGE NOZZLE180-DEGREE DISCHARGE NOZZLEPENDENT FRAME STANDARD SPRAY PATTERN DRY SPRINKLERUPRIGHT FRAME STANDARD SPRAY PATTERN DRY SPRINKLERSIDEWALL FRAME STANDARD SPRAY PATTERN DRY SPRINKLERPENDENT FRAME STANDARD SPRAY PATTERN OPEN DELUGE SPRINKLERUPRIGHT FRAME STANDARD SPRAY PATTERN OPEN DELUGE SPRINKLERSIDEWALL FRAME STANDARD SPRAY PATTERN OPEN DELUGESPRINKLERSELECTOR VALVE (GASEOUS AGENTS / WATER MIST)SYMBOLS - EXISTING EQUIPMENT**DASHED LINE-TYPE APPLIES UNIFORMLY TO EXISTING DIV. 21EQUIPMENT AND PIPING; SYMBOLS SHOWN ARE REPRESENTATIVE.EXISTING DIV. 21 EQUIPMENT AND PIPINGREMOVAL OF EXISTING DIV. 21 EQUIPMENT AND PIPINGEXISTING SPRINKLER OR NOZZLEREMOVAL OF EXISTING SPRINKLER OR NOZZLEECWSDRYECDRYDWATER FLOW SWITCHPRESSURE GAUGEABBREVIATIONSACTACOUSTICAL CEILING TILEAFFABOVE FINISH FLOORAFGABOVE FINISH GRADEAHJAUTHORITY HAVING JURISDICTIONARCHARCHITECTBLDG BUILDINGBOP BOTTOM OF PIPEBOR BOTTOM OF RISERCL CENTER LINECMU CONCRETE MASONRY UNITCONT CONTINUATIONDN DOWNDWG DRAWINGELEC ELECTRICALELEV ELEVATIONEX EXISTINGFT FEETGALV GALVANIZEDGPM GALLONS PER MINUTEGWB GYPSUM WALL BOARDHAZMAT HAZARDOUS MATERIALINV INVERTINT INTERLOCKMAX MAXIMUMMIN MINIMUMMECH MECHANICALMISC MISCELLANEOUSM METERSMM MILLIMETERSNA NOT APPLICABLENAS NO AUTOMATIC SPRINKLERSNHS NATIONAL HOSE STANDARDNC NORMALLY CLOSEDNIC NOT IN CONTRACTNO NORMALLY OPENNRTL NATIONALLY RECOGNIZED TESTING LABORATORYNTS NOT TO SCALEQTY QUANTITYSQFT SQUARE FEETSQM SQUARE METERSLPM LITERS PER MINUTETEMP TEMPERATURETOR TOP OF RISERTYP TYPICALW/ WITHABBREVIATIONS - SYSTEM DESIGNATIONSCA CLEAN AGENTDFM DRY STANDPIPE FEED-MAINDSP DRY SPRINKLERDST DRY STANDPIPEFDC FIRE DEPARTMENT CONNECTIONFSP FOAM-WATER SPRINKLERFWS FIRE WATER SERVICEHCO2 HIGH PRESSURE CARBON DIOXIDELCO2 LOW PRESSURE CARBON DIOXIDEPSP PREACTION SPRINKLERSD SPRINKLER DRAINWBFS WATER-BASED FIRE SUPPRESSIONWCST WET COMBINATION SPRINKLER / STANDPIPEWFM WET STANDPIPE FEED-MAINWSP WET SPRINKLERWST WET STANDPIPEWMST WATER MISTABBREVIATIONS - EQUIPMENT & MATERIALSACVALARM CHECK VALVEATSAUTOMATIC TRANSFER SWITCHBFP BACKFLOW PREVENTERBV BUTTERFLY OR BALL INDICATING VALVEDAV DRY-PIPE ALARM VALVEDVCA DOUBLE CHECK VALVE ASSEMBLYDCDA DOUBLE CHECK VALVE DETECTOR ASSEMBLYDRA DRY-PIPE MAIN RISER ASSEMBLYFHV FIRE HOSE VALVEFHVC FIRE HOSE VALVE CABINETFHZC FIRE HOSE VALVE & ZONE CONTROL ASSEMBLY FPU FIRE PUMPFPUC FIRE PUMP CONTROLLERFRA FOAM-WATER SPRINKLER MAIN RISER ASSEMBLYFS FLOW SWITCHLPS LOW PRESSURE SWITCHNRS NON RISING STEM GATE VALVEOSY OUTSIDE SCREW & YOKE INDICATING VALVEPIV POST INDICATING VALVEPIVW POST INDICATING VALVE - WALL MOUNTPMP PRESSURE MAINTENANCE PUMPPMPC PRESSURE MAINTENANCE PUMP CONTROLLER PRA PREACTION MAIN RISER ASSEMBLYPRAC PREACTION MAIN RISER ASSEMBLY CABINETPRV PRESSURE REGULATING VALVEPS PRESSURE SWITCHRPZA REDUCED PRESSURE ZONE ASSEMBLYSDR SPRINKLER DRAIN RISERTH TEST HEADERTS TAMPER SWITCHWAV WET-PIPE ALARM VALVEWRA WET-PIPE MAIN RISER ASSEMBLYZCA ZONE CONTROL ASSEMBLYZCAC ZONE CONTROL ASSEMBLY CABINETABBREVIATIONS - GENERAL NOTE NOT ALL ABBREVIATIONS USED FOR THIS PROJECTSYMBOLS - GENERAL NOTENOT ALL SYMBOLS USED FOR THIS PROJECTXXXECDRYESFRESFRCMSACMSAWSACCArchitectPayette Associates Architects, P.C.290 Congress Street, Fifth FloorBoston, MA 02210-1005Tel: 617-895-1000Fax: 617-895-1002MEP/FP EngineerVanderweil274 Summer StreetBoston, MA 02210Tel: 617-423-7423Structural EngineerSGH41 Seyong StreetBuilding 1, Suite 500Waltham, MA 02453Tel: 781-907-9000Fax: 781-907-9009Drawing ScaleProject NumberDate IssuedRenovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code ConsultantHastings Consulting Inc142 Hanlon RoadHollister, MA 01746Tel: 508-397-8417Lighting DesignerAvailable Light10 Derby Square #3Salem, MA 01970Tel: 978-744-6800NCost ConsultantDharam Consulting745 Atlantic Ave Fl 8Boston, MA 02111Tel: 617-913-4345Abatement SpecialistDelta860 Hooper RdEndwell, NY 13760Tel: 607-231-6600Civil EngineerT.G. Miller, P.C.203 N. Aurora StreetIthaca, NY 14850Tel: 607-272-6477NONEFP0.0129313.0011/30/18FIRE PROTECTION -SYMBOLS &ABBREVIATIONS# DATE DESCRIPTION1 11/30/18 ISSUED FOR CONSTRUCTIONDocuSign Envelope ID: 45F96879-714F-4669-B8A4-6F84201714F012/10/2018