HomeMy WebLinkAboutFA2.10FIRE ALARM - LEVEL 1300.25MM21346785QPRSTOU9S1R14AQ15.121346785QPRSTOU9S1R14AQ15.1WORK AREADISCONNECT EXISTING FLOWSWITCH FROM EXISTING TO REMAIN MONITOR MODULE. CONNECT NEW ZONECHECK ASSEMBLY TO EXISTING TO REMAIN MONITOR MODULE.XMWFLAB WRITE-UP158LAB WRITE-UP162LAB WRITE-UP160OFFICE158BLAB WRITE-UP170LAB WRITE-UP170ALAB WRITE-UP170BLAB WRITE-UP169OFFICE168OFFICE167ACONFERENCEROOM167BOFFICE167COFFICE167DOFFICE167ERoom100CKRoom167FRoom100CGRoom100CJRoom165BOFFICE152Room100SARoom165Room100UACORRIDOR100CARoom100JARoom100UBCORRIDOR100CHRoom100UFRoom167GOFFICE156COLLABORATION167WORK AREAArchitectPayette Associates Architects, P.C.290 Congress Street, Fifth FloorBoston, MA 02210-1005Tel: 617-895-1000Fax: 617-895-1002MEP/FP EngineerVanderweil274 Summer StreetBoston, MA 02210Tel: 617-423-7423Structural EngineerSGH41 Seyong StreetBuilding 1, Suite 500Waltham, MA 02453Tel: 781-907-9000Fax: 781-907-9009Drawing ScaleProject NumberDate IssuedRenovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code ConsultantHastings Consulting Inc142 Hanlon RoadHollister, MA 01746Tel: 508-397-8417Lighting DesignerAvailable Light10 Derby Square #3Salem, MA 01970Tel: 978-744-6800NCost ConsultantDharam Consulting745 Atlantic Ave Fl 8Boston, MA 02111Tel: 617-913-4345Abatement SpecialistDelta860 Hooper RdEndwell, NY 13760Tel: 607-231-6600Civil EngineerT.G. Miller, P.C.203 N. Aurora StreetIthaca, NY 14850Tel: 607-272-6477 1/4" = 1'-0"FA2.1029313.0011/30/18FIRE ALARM - LEVEL 1GENERAL NOTES:1.REFER TO ARCHITECTURAL FRAMING PLANS, DETAILED REFLECTED CEILING PLANS, ELEVATIONS, AND SECTIONS. 2.IN AREAS WITH FINISHED CEILINGS, LOCATE CEILING MOUNTED DEVICES AND APPLIANCES IN THE CENTER OF SUSPENDED CEILING TILES, ALONG THE CENTER-LINE OF CEILING FEATURES AND IN-LINE WITH ADJACENT CEILING FIXTURES.3.LOCATE WALL MOUNTED DEVICES AND APPLIANCES IN ACCORDANCE WITH NFPA 72 REQUIREMENTS AND IN ALIGNMENT WITH ADJACENT WALL MOUNT SWITCHES, WALL PLATES AND SIMILAR ELEMENTS.4.LOCATE CEILING MOUNTED SMOKE AND HEAT DETECTORS WITH RESPECT TO CEILING POCKETS AND OBSTRUCTIONS SUCH AS EXPOSED BEAMS AND SOFFITS IN ACCORDANCE WITH NFPA 72.5.COMPLY WITH NFPA 72 AND THE DESIGN INTENT INDICATED ON THE DRAWINGS WITH RESPECT TO INTERFACES REQUIRED FOR EMERGENCY CONTROL FUNCTIONS SUCH AS (BUT NOT LIMITED TO) ELEVATOR RECALL, FIRE / SMOKE DAMPER OPERATION, AND HVAC UNIT SHUTDOWN. DETERMINATION OF THE EXACT QUANTITY AND ARRANGEMENT OF INTERFACE MODULES REQUIRED SHALL BE THE RESPONSIBILITY OF THE INSTALLER'S QUALIFIED DESIGNER.6.SHOP DRAWINGS INCLUSIVE OF DEVICE AND APPLIANCE LAYOUTS, PATHWAYS AND CIRCUITING, COMPONENT ADDRESSES, EMERGENCY CONTROL INTERFACES AND CORRESPONDING CALCULATIONS SHALL BE PREPARED BY THE INSTALLER'S QUALIFIED DESIGNER. SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW AND SHALL BE USED FOR FIRE ALARM SYSTEM INSTALLATION PERMITS. # DATE DESCRIPTION1 11/30/18 ISSUED FOR CONSTRUCTIONDocuSign Envelope ID: 45F96879-714F-4669-B8A4-6F84201714F012/10/2018