Loading...
HomeMy WebLinkAboutFA0.01FIRE ALARM - SYMBOLS & ABBREVIATIONSMMRMCMIPCTIPCRDCCTDCCR#EcMBFFJFFPFFPCOABDAABDADACTFSRUcFSRUFXcFcMICRMDKBISJBRTSRTPRPSRAIPRNGAPFFSCPFATCFACUFAADARTDARRDACRADSPAFXFNOT ALL SYMBOLS USED FOR THIS PROJECTSYMBOLS - GENERAL NOTEMONITOR MODULERELAY MODULECONTROL MODULESYMBOLS - INTERFACE MODULESINTERNET PROTOCOL COMMUNICATION TRANSMITTERINTERNET PROTOCOL COMMUNICATION RECEIVERDIGITAL CELLULAR COMMUNICATION TRANSMITTERDIGITAL CELLULAR COMMUNICATION RECEIVERSYMBOLS - MANUAL INITIATING DEVICES AND CONTROLSMANUAL PULL STATION (CONVENTIONAL) - EMERGENCY ALARM (HAZMAT)SYMBOLS - GENERAL ANNOTATIONSYMBOLS - WIRED FIRE FIGHTER COMMUNICATION SYSTEMSFIRE FIGHTER'S PHONE PLUG-IN PHONE JACKFIRE FIGHTER'S PHONE HANDSETFIRE FIGHTER'S PHONE CONTROLLER / HANDSET - PRIORITY COMMANDLOCATIONSYMBOLS - RADIO PES COMMUNICATIONS ENHANCEMENT SYSTEMSOMNI DIRECTIONAL ANTENNABI-DIRECTIONAL RADIO SIGNAL AMPLIFIER ALARM PANELBI-DIRECTIONAL RADIO SIGNAL AMPLIFIERAUDIBLE ALARM BELLBASIC SYMBOL FOR CONVENTIONAL FIRE DETECTOR - CEILING MOUNTBASIC SYMBOL FOR CONVENTIONAL FIRE DETECTOR - WALL MOUNTCONVENTIONAL FIXED TEMPERATURE HEAT DETECTOR (t = ACTIVATIONTEMPERATURE)CONVENTIONAL PHOTOELECTRIC SMOKE DETECTORSYMBOL - CONVENTIONAL SPOT-TYPE FIRE DETECTORSBASIC SYMBOL FOR SPOT-TYPE FIRE DETECTOR - W/ SOUNDER BASEVISUAL FLASHING BEACONCOMBINATION AUDIBLE & INTELLIGIBLE SPEAKER / VISUAL STROBE -CLNG MOUNTCOMBINATION AUDIBLE & INTELLIGIBLE SPEAKER / VISUAL STROBE -WALL MOUNTAUDIBLE & INTELLIGIBLE SPEAKER - WALL MOUNTAUDIBLE & INTELLIGIBLE SPEAKER - CLNG MOUNTCOMBINATION AUDIBLE HORN / VISUAL STROBE - CLNG MOUNTCOMBINATION AUDIBLE HORN / VISUAL STROBE - WALL MOUNTVISUAL STROBE - CLNG MOUNTVISUAL STROBE - WALL MOUNTSYMBOLS - NOTIFICATION APPLIANCESAUDIBLE HORN - WALL MOUNTAUDIBLE HORN - CLNG MOUNTCOMBINATION ULTRAVIOLET / INFRARED SPECTRUM FLAME DETECTORINFRARED SPECTRUM FLAME DETECTORULTRAVIOLET SPECTRUM FLAME DETECTORBASIC SYMBOL FOR SPECIAL TECHNOLOGY FIRE DETECTOR -WALLMOUNTBASIC SYMBOL FOR SPECIAL TECHNOLOGY FIRE DETECTOR -CLNGMOUNTBASIC SYMBOL FOR SMOKE ALARM - CEILING MOUNTBASIC SYMBOL FOR SMOKE ALARM - WALL MOUNTSINGLE / MULTIPLE STATION COMBINATION SMOKE / CO ALARMSINGLE / MULTIPLE STATION SMOKE ALARMSYMBOLS - SINGLE / MULTIPLE STATION SMOKE ALARMSSYMBOLS - SYSTEM SPOT-TYPE FIRE DETECTORSSYMBOLS - SPECIAL TECHNOLOGY FIRE DETECTORSPHOTOELECTRIC SMOKE DETECTORCOMBINATION AIR SAMPLING SMOKE / H2 DETECTORCOMBINATION AIR SAMPLING SMOKE / CO DETECTORMULTI-CRITERIA PHOTOELECTRIC SMOKE / FIXED TEMP HEAT / CODETECTOR (t = ACTIVATION TEMPERATURE OF THERMAL ELEMENT)COMBINATION PHOTOELECTRIC SMOKE / CO DETECTORCOMBINATION PHOTOELECTRIC SMOKE / FIXED TEMP HEAT DETECTOR (t= ACTIVATION TEMPERATURE OF THERMAL ELEMENT)FIXED TEMPERATURE / RATE OF RISE HEAT DETECTOR (t = ACTIVATIONTEMPERATURE OF FIXED TEMP THERMAL ELEMENT)SINGLE-END OPTICAL BEAM SMOKE DETECTOR (REFLECTOR PANEL)END-TO-END OPTICAL BEAM SMOKE DETECTOR (RECEIVER UNIT)SINGLE-END OPTICAL BEAM SMOKE DETECTOR (TRANSMITTER /RECEIVER UNIT)BASIC SYMBOL FOR SPOT-TYPE FIRE DETECTOR - WALL MOUNTBASIC SYMBOL FOR SPOT-TYPE FIRE DETECTOR - CLNG MOUNTAIR SAMPLING SMOKE DETECTOREND-TO-END OPTICAL BEAM SMOKE DETECTOR (TRANSMITTER UNIT)PHOTOELECTRIC SAMPLING-TUBE DUCT SMOKE DETECTORPHOTOELECTRIC IN-DUCT SMOKE DETECTORDIGITAL ALARM COMMUNICATOR TRANSMITTERFIRE SUPPRESSION RELEASING CONTROL UNIT (CONVENTIONAL)FIRE SUPPRESSION RELEASING CONTROL UNITMANUAL PULL STATION (CONVENTIONAL) - FIRE SUPPRESSION SYSTEMRELEASEFIRE ALARM MANUAL PULL STATION (CONVENTIONAL)EMERGENCY VOICE MICROPHONE MODULEMAGNETIC DOOR HOLDERKEY BOXISOLATION MODULEJUNCTION BOXEND OF LINE RESISTORREMOTE TEST SWITCHROOM TEMPERATURE SWITCHREMOTE POWER SUPPLYREMOTE ALARM INDICATORPRINTERMUNICIPAL MASTER BOXGRAPHIC ANNUNCIATOR PANELFIRE FIGHTER'S SMOKE CONTROL PANELFIRE ALARM TERMINAL CABINETFIRE ALARM CONTROL UNIT (# = NODE DESIGNATION)FIRE ALARM REMOTE ANNUNCIATORDIGITAL ALARM RADIO TRANSMITTERDIGITAL ALARM RADIO RECEIVERDIGITAL ALARM COMMUNICATOR RECEIVERAIR SAMPLING SMOKE DETECTOR POWER SUPPLYSYMBOLS - EQUIPMENT & COMPONENTSMANUAL PUSH BUTTON - FIRE SUPPRESSION SYSTEM ABORTMANUAL PULL STATION - FIRE SUPPRESSION SYSTEM RELEASEFIRE ALARM MANUAL PULL STATIONABBREVIATIONS A AMPERESACT ACOUSTICAL CEILING TILEAFF ABOVE FINISH FLOORAFG ABOVE FINISH GRADEAHJ AUTHORITY HAVING JURISDICTIONARCH ARCHITECTAWG AMERICAN WIRE GAUGEBLDG BUILDINGCL CENTER LINECMU CONCRETE MASONRY UNITCO CARBON MONOXIDECONT CONTINUATIONDWG DRAWINGELEC ELECTRICALELEV ELEVATIONEX EXISTINGFT FEETGALV GALVANIZEDGND GROUNDGWB GYPSUM WALL BOARDHAZMAT HAZARDOUS MATERIALMAX MAXIMUMMIN MINIMUMMECH MECHANICALMISC MISCELLANEOUSM METERSMM MILLIMETERSNA NOT APPLICABLENC NORMALLY CLOSEDNIC NOT IN CONTRACTNO NORMALLY OPENNRTL NATIONALLY RECOGNIZED TESTING LABORATORYNTS NOT TO SCALEPES PUBLIC EMERGENCY SERVICEQTY QUANTITYSQFT SQUARE FEETSQM SQUARE METERSTEMP TEMPERATURETYP TYPICALV VOLTSW/ WITHWP WEATHER PROOFXP EXPLOSION PROOFABBREVIATIONS - SYSTEMS, EQUIPMENT, AND MATERIALSACU AUTONOMOUS CONTROL UNITAMP AMPLIFIERASSD AIR-SAMPLING SMOKE DETECTORAUX AUXILIARY 24V POWER CIRCUITAVC ANALOG VOICE CIRCUITBDA BI-DIRECTIONAL AMPLIFIERBDAA BI-DIRECTIONAL AMPLIFIER ALARM PANELCAX COAXIAL CABLECOM NETWORK COMMUNICATION CIRCUITDVC DIGITAL VOICE CIRCUITECS EMERGENCY COMMUNICATION SYSTEMEMT ELECTRICAL METALLIC TUBINGEOL END OF LINE RESISTORFACU FIRE ALARM CONTROL UNITFAS FIRE ALARM SYSTEMFATC FIRE ALARM TERMINAL CABINETFMC FLEXIBLE METALLIC CONDUITFMCL LIQUID TIGHT FLEXIBLE METALLIC CONDUITFO FIBER OPTIC CABLEFPL POWER LIMITED FIRE ALARM CABLEFPLP POWER LIMITED FIRE ALARM CABLE - PLENUMFPLR POWER LIMITED FIRE ALARM CABLE - RISERFSRU FIRE SUPPRESSION RELEASING UNITFT FIXED TEMPERATUREGAP GRAPHIC ANNUNCIATOR PANELHLI HIGH LEVEL INTERFACEIDC INITIATING DEVICE CIRCUITIM INTERFACE MODULEJB JUNCTION BOXMC METAL CLAD CABLEMD MAGNETIC DOOR HOLD-OPENMFVN MANAGED FACILITIES-BASED VOICE NETWORKNAC NOTIFICATION APPLIANCE CIRCUITPP PROTECTED PREMISESPRN PRINTERPSTN PUBLIC-SWITCHED TELEPHONE NETWORKRAI REMOTE ALARM INDICATORRCES RADIO COMMUNICATION ENHANCEMENT SYSTEMROR RATE OF RISERMC RIGID METALLIC CONDUITRPS REMOTE POWER SUPPLYRS RELEASING SERVICESLC SIGNALING LINE CIRCUITSPK SPEAKER CIRCUITSTR STROBE CIRCUITTB TERMINAL BLOCKABBREVIATIONS - GENERAL NOTESNOT ALL ABBREVIATIONS USED FOR THIS PROJECTcdwwcdCcdwCcdwCcdcdCASBTBTRBRBRFASASUVIRUVIRtttCOH2COCOCOtzdwgxdwgydwgSECTION NUMBERCONNECT TO EXISTINGDRAWING NUMBERELEVATION NUMBERDRAWING NUMBERDETAIL / PART-PLAN NUMBERDRAWING NUMBERKEY NOTE##AMPAMPLIFIERBATT BATTERY CABINETACEACCESSORY CABINET ENCLOSUREABBREVIATIONS - FAS INTERFACE MODULE / FIRE SUPPRESSION FSA FSRU COMMON ALARM OUTPUT (MM)FSAD FSRU CLEAN AGENT DISCHARGE OUTPUT (MM)FSS FSRU COMMON SUPERVISORY OUTPUT (MM)FST FSRU COMMON TROUBLE OUTPUT (MM)FSWF FSRU WATER FLOW OUTPUT (MM)LPS LOW AIR OR WATER SPRINKLER / STANDPIPE SYSTEM PRESSURE (MM)N2P NITROGEN GENERATOR LOW PURITY (MM)RCA ENERGIZE CLEAN AGENT RELEASING ACTUATOR (RM)RSL ENERGIZE PREACTION SPRINKLER RELEASING SOLENOID (RM)TS SPRINKLER / STANDPIPE VALVE TAMPER SWITCH IN OFF- NORMAL POSITION (MM)TSC CLEAN AGENT ACTUATOR CONTROL HEAD TAMPER SWITCH IN OFF-NORMAL POSITION (MM)WF SPRINKLER / STANDPIPE SYSTEM WATER FLOW (MM)ABBREVIATIONS - FAS / ELECTRIC FIRE PUMP INTERFACESFPCS FIRE PUMP CONNECTED TO STANDBY POWER (MM)FPPL FIRE PUMP POWER PHASE LOSS (MM)FPPV FIRE PUMP POWER PHASE REVERSAL (MM)FPRN FIRE PUMP RUNNING (MM)FPVB FIRE PUMP VFD BYPASS ENGAGED (MM)FPVF FIRE PUMP VFD FAILURE (MM)FPVO FIRE PUMP VFD OVERPRESSURE (MM)ABBREVIATIONS - FAS / DIESEL FIRE PUMP INTERFACESFPET FIRE PUMP ENGINE TROUBLE (MM)FPLF FIRE PUMP LOW FUEL (MM)FPMS FIRE PUMP MAIN SWITCH IN OFF OR MANUAL POSITION (MM)FPRN FIRE PUMP RUNNING (MM)ABBREVIATIONS - FAS / ELEVATOR INTERFACESELAI ACTIVATE "FLASHING HAT" ALARM INDICATOR (RM)ELHV OPEN ELEVATOR HOISTWAY VENT (RM)ELRA RECALL CAB(S) TO ALTERNATE RECALL LEVEL (RM)ELRP RECALL CAB(S) TO PRIMARY RECALL LEVEL (RM)ELSP SHUNT ELEVATOR POWER (RM) ABBREVIATIONS - FAS / HVAC & SMOKE CONTROL INTERFACES@-AFL SMOKE CONTROL FAN ID "@" AIRFLOW VERIFICATION (MM)@-DSC SMOKE CONTROL FAN ID "@" LOCAL POWER DISCONNECT OPEN (MM)@-CL DAMPER / COMPONENT ID "@" IN CLOSED POSITION (MM) @-OP DAMPER / COMPONENT ID "@" IN OPEN POSITION (MM)CL-@ CLOSE DAMPER / COMPONENT ID "@" (RM)FSD FIRE SMOKE DAMPER (RM)OP-@ OPEN DAMPER / COMPONENT ID "@" (RM)STA-@ START HVAC / SMOKE CONTROL FAN ID "@" (RM)STP-@ STOP HVAC / SMOKE CONTROL FAN ID "@" (RM)XDCT CONVENTIONAL DUCT SMOKE DETECTOR ALARM (MM)ABBREVIATIONS - BI-DIRECTIONAL AMPLIFIER INTERFACESBDAC LOSS OF AC POWER (MM)BDAM ANTENNA MALFUNCTION (MM)BDLB LOW BATTERY (MM)BDSM SIGNAL BOOSTER FAILURE (MM)ABBREVIATIONS - CONVENTIONAL INITIATING DEVICESFC CONVENTIONAL FIRE ALARM MANUAL PULL STATION (MM)HDA CONVENTIONAL HEAT DETECTOR ALARM (MM)ABBREVIATIONS - FAS / OTHER SYSTEM INTERFACES@-PW EQUIPMENT ID "@" POWER OFF NORMAL (MM)BMSA FAS COMMON ALARM TO BMS (RM)BMSS FAS COMMON SUPERVISORY TO BMS (RM)BMST FAS COMMON TROUBLE TO BMS (RM)DR RELEASE DOOR(S) (RM)ETLO OVERRIDE ENTERTAINMENT LIGHTING CONTROLS - SET TO FULL "NON EVENT" LIGHTING LEVELS (RM)ETSO OVERRIDE ENTERTAINMENT SOUND CONTROLS - MUTE SOUND (RM)FOP SHUT DOWN FUEL OIL PUMP(S) (RM)GAS ENERGIZE NATURAL GAS SUPPLY SHUTOFF SOLENOID (RM)GENR EMERGENCY / STANDBY GENERATOR RUNNING (MM)PASO OVERRIDE PUBLIC ADDRESS SYSTEM - MUTE SOUND (RM)SECA FAS COMMON ALARM SIGNAL TO SECURITY SYSTEM (RM)SECS FAS COMMON SUPERVISORY SIGNAL TO SECURITY SYSTEM (RM)SECT FAS COMMON TROUBLE SIGNAL TO SECURITY SYSTEM (RM)SYMBOLS - EXISTING EQUIPMENTEXISTING EQUIPMENT DESIGNATION ("EX"):XM EXISTING EQUIPMENT TO REMAIN. WHERE ARCHITECTURAL WORK IS REQUIRED AT DEVICE LOCATION, DISCONNECT, REMOVE AND REINSTALL DEVICE AS NECESSARY TO ACCOMMODATE ARCHITECTURAL WORK. FOR SURFACE MOUNTED RACEWAY, THIS DESIGNATION SHALL INDICATE RACEWAY AND DEVICES TO REMAIN UNLESS OTHERWISE NOTED.XN EXISTING EQUIPMENT TO BE DISCONNECTED, REMOVED AND REPLACED WITH NEW. EXISTING CIRCUIT WIRING AND PATHWAY TO BE MAINTAINED AND REUSED FOR NEW EQUIPMENT CONNECTION.XR EXISTING EQUIPMENT TO NEW "XL" LOCATION. CUT BACK AND/OR EXTEND EXISTING CIRCUIT WIRING AND PATHWAY AS REQUIRED SO AS TO PROVIDE A COMPLETE OPERATIONAL INSTALLATION.XL EXISTING RELOCATED "XR" EQUIPMENT AT "XL" NEW LOCATION. XD REMOVE EXISTING EQUIPMENT. PROVIDE NOTICE TO OWNER OF EQUIPMENT REMOVED. AS DIRECTED BY THE OWNER, BOX REMOVED EQUIPMENT AND RETURN TO THE OWNER AS SPARE INVENTORY. SYMBOLS - NOTIFICATION APPLIANCE ANNOTATIONC = CEILING MOUNTcd = VISUAL STROBE CANDELA OUTPUTw= SPEAKER WATTAGE TAPFACP FIRE ALARM CONTROL PANELArchitectPayette Associates Architects, P.C.290 Congress Street, Fifth FloorBoston, MA 02210-1005Tel: 617-895-1000Fax: 617-895-1002MEP/FP EngineerVanderweil274 Summer StreetBoston, MA 02210Tel: 617-423-7423Structural EngineerSGH41 Seyong StreetBuilding 1, Suite 500Waltham, MA 02453Tel: 781-907-9000Fax: 781-907-9009Drawing ScaleProject NumberDate IssuedRenovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code ConsultantHastings Consulting Inc142 Hanlon RoadHollister, MA 01746Tel: 508-397-8417Lighting DesignerAvailable Light10 Derby Square #3Salem, MA 01970Tel: 978-744-6800NCost ConsultantDharam Consulting745 Atlantic Ave Fl 8Boston, MA 02111Tel: 617-913-4345Abatement SpecialistDelta860 Hooper RdEndwell, NY 13760Tel: 607-231-6600Civil EngineerT.G. Miller, P.C.203 N. Aurora StreetIthaca, NY 14850Tel: 607-272-6477NONEFA0.0129313.0011/30/18FIRE ALARM - SYMBOLS& ABBREVIATIONS# DATE DESCRIPTION1 11/30/18 ISSUED FOR CONSTRUCTIONDocuSign Envelope ID: 45F96879-714F-4669-B8A4-6F84201714F012/10/2018