E5.01ELECTRICAL EMERGENCY POWER RISER DIAGRAMS
4#1/0 AL&1#6 AL, 1 1/2"C 01 11 21 31 12 22 32 41 02 21 31 250AT 100AT 250AT 100AT 250AT 100AT 250AT 100AT 250AT 100AT 250AT 100AT 250AT 100AT ELAB-1B NORTH PENTHOUSE 400UC TRANSFER SWITCH ROOM - BOOUP ELEC. ROOM 400UR LEVEL 0 LEVEL 1 LEVEL 2 LEVEL 4 LEVEL 3 ROOF ELEC. ROOM 300UR ELEC. ROOM 200UR ELEC. ROOM 100UR ELECTRICAL CLOSET ELECTRICAL CLOSET NORTH PENTHOUSE 400UC MECHANICAL ROOM 403 LEVEL 0 LEVEL 1 LEVEL 2 LEVEL 4 LEVEL 3 ROOF EXISTING CORRIDOR 300CA EXISTING CORRIDOR 200CA EXISTING COLLABORATION 167 OPEN RESEARCH LAB 276 EXISTING CORRIDOR B00CA TRANSFER SWITCH ROOM - BOOUP ELECTRICAL CLOSET SUPPORT 1 367D EXISTING COLLABORATION 167 ELEC. ROOM 400UR ELEC. ROOM 300UR ELEC. ROOM 200UR ELEC. ROOM 100UR ELEC. ROOM B00UR ELEC. ROOM B00UR ELECTRICAL CLOSET ELECTRICAL CLOSET ELECTRICAL CLOSETCORRIDOR CORRIDOR CORRIDOR EXISTING CORRIDOR B00CA ATS 2 ATS 3ATS 1 ECB CB-E1 T-E1 EMERGENCY BUS RISER "E1" ESD-BEEDPEDP T7 EODP ESD-P TO A 400 KW/500KVA OUTDOOR GENERATOR E-LAB-3B ELAB-2B EXISTING OPTIONAL STANDBY DISTRIBUTION BRANCH #3 EXISTING OPTIONAL STANDBY DISTRIBUTION BRANCH #2 EXISTING EMERGENCY DISTRIBUTION BRANCH #1 ELAB-BB KEY NOTE DESCRIPTION 01 EXISTING PANELBOARDS E-LAB-BB TO REMAIN. 11 EXISTING PANELBOARDS E-LAB-1B TO REMAIN. ELECTRICAL KEYNOTES LEVEL 2 DISTRIBUTION 21 EXISTING PANELBORD E-LAB-2B TO BE REMOVED AND RELOCATED TO ACCOMMODATE THE RENOVATION. EXISTING FEEDER SHOWN BASED ON RECORD DRAWING. 31 EXISTING PANELBORD E-LAB-3B TO BE REMOVED AND RELOCATED TO ACCOMMODTE THE RENOVATION. EXISTING FEEDER SHOWN BASED ON RECORD DRAWING. ATS 2 ATS 3ATS 1 ECB CB-E1 T-E1 EMERGENCY BUS RISER "E1" ESD-BEEDPEDP T7 EODP TO A 400 KW/500KVA OUTDOOR GENERATOR ELAB-BB ESD-P EXISTING EMERGENCY POWER DISTRIBUTION ELAB-1B HELP-3 HELP-2 HELP-1 HELP-4 EXISTING PANELBOARD HELP-1 TO REMAIN AND REUSED TO SUPPLY THE NEW RENOVATED SPACE.12 EXISTING PANELBOARD HELP-2 TO REMAIN AND REUSED TO SUPPLY THE NEW RENOVATED SPACE.22 EXISTING PANELBOARD HELP-3 TO REMAIN AND REUSED TO SUPPLY THE NEW RENOVATED SPACE.32 ELECTRICAL KEYNOTES LEVEL 3 DISTRIBUTION ELECTRICAL KEYNOTES LEVEL 1 DISTRIBUTION ELECTRICAL KEYNOTES LEVEL 0 DISTRIBUTION ELECTRICAL KEYNOTES LEVEL 4 DISTRIBUTION EXISTING PANELBOARD HELP-4 TO REMAIN AND REUSED TO SUPPLY THE NEW RENOVATED SPACE.41 KEY NOTE DESCRIPTION 21 INTERCEPT EXISTING PANELBOARD E-LAB-2B FEEDER AND EXTEND TO NEW PANELBOARD LOCATION. NEW FEEDER TO MATCH EXISTING. 31 INTERCEPT EXISTING PANELBOARD E-LAB-3B FEEDER AND EXTEND TO NEW PANELBOARD LOCATION. NEW FEEDER TO MATCH EXISTING. HELP-B EXISTING PANELBOARD HELP-B TO REMAIN AND REUSED TO SUPPLY THE NEW RENOVATED SPACE.02 EXISTING OPTIONAL STANDBY DISTRIBUTION BRANCH #3 EXISTING OPTIONAL STANDBY DISTRIBUTION BRANCH #2 EXISTING EMERGENCY DISTRIBUTION BRANCH #1 E-LAB-3B ELAB-2B J J HELP-3 HELP-2 HELP-1 HELP-4 HELP-B ELECTRICAL KEYNOTES LEVEL 2 DISTRIBUTION ELECTRICAL KEYNOTES LEVEL 23DISTRIBUTION NEW EMERGENCY POWER DISTRIBUTION 4#1/0 AL&1#6 AL, 1 1/2"C 208/120, 3Φ, 4W 208/120V, 3Φ, 4W 480/277V, 3Φ, 4W 208/120, 3Φ, 4W 208/120, 3Φ, 4W 4#1/0 AL&1#6 AL, 1 1/2"C 4#1/0 AL&1#6 AL, 1 1/2"C 208/120, 3Φ, 4W 208/120V, 3Φ, 4W 208/120V, 3Φ, 4W 480/277V, 3Φ, 4W 480/277V, 3Φ, 4W 480/277V, 3Φ, 4W 480/277V, 3Φ, 4W 480/277V, 3Φ, 4W 480/277V, 3Φ, 4W 480/277V, 3Φ, 4W208/120, 3Φ, 4W 480/277V, 3Φ, 4W 480/277V, 3Φ, 4W208/120, 3Φ, 4W Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 N.T.S E5.01 29313.00 11/30/18 ELECTRICAL EMERGENCY POWER RISER DIAGRAMS # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION DocuSign Envelope ID: DAB23A5A-6B4E-4542-874F-F48E2BF76454 12/10/2018