HomeMy WebLinkAboutE4.01ELECTRICAL - PART PLANS - SHEET 2EF A.2 EF A.1 J G S1 S1 H G 17 U 2423 XM XM ELP1-401A ELP2-401 XD DISCONNECT AND CUT BACK EXISTING POWER/COMM. RACEWAYS AND CIRCUITS ON BOTH SIDES OF THIS WALL TO ACCOMMODATE WALL DEMO. DISCONN. AND REMOVE EXISTING CLOCK RECEPT. XD EXISTING POWER/ COMM. RACEWAY XM XM XM EXISTING 208V POWER PANEL EXISTING 208V POWER PANEL THIS ROOM IS BEING DEMOLISHED. DISCONNECT AND REMOVE ALL EXISTING LIGHTING, CONTROLS, POWER DEVICES AND CIRCUITS BACK TO SOURCE THIS CLOSET IS BEING DEMOLISHED. DISCONNECT AND REMOVE ALL EXISTING LIGHTING, CONTROLS, POWER DEVICES AND CIRCUITS BACK TO SOURCE XD XD XM XM XM XD XD XD XD XD XM XD XM XD XD XM XM INTERCEPT EXISTING CIRCUITING AND EXTEND AND RECONNECT TO EXISTING CIRCUIT AT PANELBOARD 3 4 6 R S S1 R1 4A XM Room 400UC Room 400SA ESD-P #7,9,11 ESD-P #1,3,5 ESD-P XMXMXM WP PENTHOUSE-N #14 PENTHOUSE-N #13 AHU LIGHTS VFD PENTHOUSE-N EXISTING PANEL EXISTING PANEL MS MS VFD VFDVFD EXHAUST FAN EF-A-1 EXHAUST FAN EF-A-2 XM WP H G 17 U 2423 ELP1-401A ELP2-401 XMXM XMXM XM XM (EXISTING) (EXISTING) Room 400UA XM XM XM XM XM XM XM XM XM XM 3 6 R S R1 4A ESD-P XMVFD XM XM EXISTING PANEL "PENTHOUSE-N" EXISTING PANEL MS XM XM MS H G 17 U 2423 R1 FC3 XM XD XMXM XM XM XM XM XD XN XR FC1 FC1 FC2 FC2 FC2 FC2 XN FC1 d dXM XD c c c a b a a b a a b XD XD H G 17 U 2423 R1 FC1 FC1 FC2 FC2 FC2 FC2 FC1 d d a a a b a b a b b b a a XL X1 X1 NEW NEW XM XM XM XM XM XM XM FC1 XMb b a PROVIDE NEW 2 X 4 PRISMATIC FLUORESCENT SIMILAR TO EXISTING . CONNECT TO EXISTING CIRCUITING. Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 1/4" = 1'-0" E4.01 29313.00 11/30/18 ELECTRICAL - PART PLANS - SHEET 2 1/4" = 1'-0"1 ELECTRICAL DISTRIBUTION PLAN - LEVEL 4 SOUTH EXISTING - PART PLAN 1/4" = 1'-0"3 LEVEL 4 ELECTRICAL NORTH NEW WORK - PART PLAN 1/4" = 1'-0"4 LEVEL 4 ELECTRICAL SOUTH NEW WORK PART PLAN 1/4" = 1'-0"2 ELECTRICAL DISTRIBUTION PLAN - LEVEL 4 NORTH EXISTING - PART PLAN # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION 2 12/18/18 ADDENDUM 01 3 1/7/18 ADDENDUM 02 1/4" = 1'-0"5 ELECTRICAL LIGHTING PLAN - LEVEL 4 EXISTING PART PLAN 1/4" = 1'-0"6 ELECTRICAL LIGHTING PLAN - LEVEL 4 PART NEW PLAN 3 3 DocuSign Envelope ID: BF852761-98AC-4A3D-B58A-A23A15AF7659 1/4/2019