Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E4.00ELECTRICAL PART PLANS - SHEET 1
T7T5T8*T8*T3*T7ATSATSATSG 16 17 R1 PDP-BB T-EAST-1 T-EAST-1 MDP T-ESD-C ESD-C LDP-B DP-B T-DP-B T-PDP-BB Room B45 Room B00UD HEPP-B 3 TOXIC GAS MONITORING PANEL H 24 LEPP-B HELP-B HLP-B LPP-B Room B00UR EXISTING OPT. STANDBY BUS RISER E-1 EXISTING NORMAL BUS RISER EAST-1 E-LAB-BB LAB-BFLAB-BCLPP-B 15 U 14 ELPB1 EEDP ESDB EODP EDPT-E1 ATS-1 ATS-2 ATS-3 Room B00UP H 24 HLP-2 HELP-2 LEPP-2 Room 200UR EXISTING OPT. STANDBY BUS RISER E-1 EXISTING NORMAL BUS RISER EAST-1 E-LAB-2B LAB-2FLAB-2CLPP-2 H 24 LEPP-3 HELP-3 HLP-3 LPP-3 Room 300UR EXISTING OPT. STANDBY BUS RISER E-1 EXISTING NORMAL BUS RISER EAST-1 LAB-3C LAB-3FLPP-3 E-LAB-3B H 24 HLP-1 HELP-1 LEPP-1 Room 100UR EXISTING OPT. STANDBY BUS RISER E-1 EXISTING NORMAL BUS RISER EAST-1 E-LAB-1B LAB-1FLPP-1 LAB-1C LPP-1 Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 1/4" = 1'-0" E4.00 29313.00 11/30/18 ELECTRICAL PART PLANS - SHEET 1 1/4" = 1'-0"2 PART PLAN - LEVEL 0 - ELEC. ROOM B00UD 1/4" = 1'-0"6 PART PLAN - LEVEL 0 - ELEC. ROOM B00UR 1/4" = 1'-0"1 PART PLAN - LEVEL 0 - ELEC. ROOM B00UP 1/4" = 1'-0"4 PART PLAN - LEVEL 2 - ELEC. ROOM 200UR 1/4" = 1'-0"3 PART PLAN - LEVEL 3 - ELEC. ROOM 300UR ELECTRICAL SHEET NOTES 1 REFER TO E0.01 FOR LEGEND, SCHEDULE AND GENERAL NOTES 2 REFER TO E5.00 FOR NORMAL POWER RISER DIAGRAMS 3 REFER TO E5.01 FOR EMERGENCY POWER RISER DIAGRAMS KEY NOTES - PART PLANS 1 EXISTING DISTRIBUTION PANEL SERVING OPTIONAL STANDBY PANEL WITHIN LEVEL 0 SCOPE OF WORK 2 EXISTING ENCLOSED CIRCUIT BREAKER SERVING LEVEL 0 OPTIONAL STANDBY PANEL WITHIN SCOPE OF WORK 3 EXISTING ENCLOSED CIRCUIT BREAKER SERVING LEVEL 0 NORMAL PANEL WITHIN SCOPE OF WORK 4 EXISTING ENCLOSED CIRCUIT BREAKER SERVING LEVEL 1 OPTIONAL STANDBY PANEL WITHIN SCOPE OF WORK 5 EXISTING ENCLOSED CIRCUIT BREAKER SERVING LEVEL 1 NORMAL PANEL WITHIN SCOPE OF WORK 6 EXISTING ENCLOSED CIRCUIT BREAKER SERVING LEVEL 2 OPTIONAL STANDBY PANEL WITHIN SCOPE OF WORK 7 EXISTING ENCLOSED CIRCUIT BREAKER SERVING LEVEL 2 NORMAL PANEL WITHIN SCOPE OF WORK 8 EXISTING ENCLOSED CIRCUIT BREAKER SERVING LEVEL 3 OPTIONAL STANDBY PANEL WITHIN SCOPE OF WORK 9 EXISTING ENCLOSED CIRCUIT BREAKER SERVING LEVEL 3 NORMAL PANEL WITHIN SCOPE OF WORK 10 EXISTING EMERG. PANEL SERVING LEVEL 0 SCOPE OF WORK 11 NOTE NOT USED 12 EXISTING EMERG. PANEL SERVING LEVEL 2 SCOPE OF WORK 13 EXISTING EMERG. PANEL SERVING LEVEL 3 SCOPE OF WORK 1/4" = 1'-0"5 PART PLAN - LEVEL 1 - ELEC. ROOM 100UR # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION 2 12/18/18 ADDENDUM 01 3 1/7/18 ADDENDUM 02 3 DocuSign Envelope ID: BF852761-98AC-4A3D-B58A-A23A15AF7659 1/4/2019