E1.00LEVEL 0 - PHASE 1 ELECTRICAL DEMO PLAN
1 M L K J I H G F E D C B A N 21 3 4 6 7 8 5 Q P R S T O 10 13 15 16 17 U 18 19 20 21 24 2523 26 9 11 12 14 S1 R1 4A Q1 22 5.1 23.1 26.1 REMOVE ALL EXISTING LIGHTS AND POWER WITHIN DESIGNATED AREA E-LAB-BB LAB-BF PDP-BA MECHANICAL B00UA MECHANICAL B00UA Room B00CA Room B78 Room B00JB Room 138 Room B40A Room 180 Room 182 Room 183 Room B01 Room B05 Room B00UH MECHANICAL B00UA Room 129 Room B00UG Room B00TB Room B00UR Room B45 Room B00UM Room B00CD Room 141 Room B00SB Room B00SA Room B59 Room B54 Room B50 Room B52 Room B48 Room B46 Room B49 Room B00UL Room B56 Room B40 Room B53 Room B55 Room B57 Room B00UN Room B00CA Room B00EB Room B00UB Room B00UC Room B40C Room B00UP Room B00UE Room B00UF Room B00UD Room B11 E2.10 1 E3.00 1 E4.00 6 E4.00 2 E4.00 1 3 Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 3/32" = 1'-0" E1.00 29313.00 11/30/18 LEVEL 0 - PHASE 1 ELECTRICAL DEMO PLAN 3/32" = 1'-0"1 ELECTRICAL DEMO PLAN - LEVEL 0 ELECTRICAL KEY NOTES - LEVEL 0 1 EXISTING PANELBOARD CLEAN 2 EXISTING PANELBOARD CRP1 3 EXISTING PANELBOARD CRC1 4 EXISTING STARTER AND BACK/BOOST TRANSFORMERS 5 EXISTING PANELBOARD LAB-BF 6 EXISTING PANELBOARD ELAB-BB 7 EXISTING PANELBOARD PDP-BA 8 PROPOSED NEW FEEDER ROUTING. CONTRACTOR TO REMOVE AND REINSTALL EXISTING CEILINGS AND LIGHT FIXTURES TO PERMIT INSTALLATION . REVIEW ABOVE-CEILING CONDITIONS AND DETERMINE PREFERRED ROUTING ELECTRICAL SHEET NOTES 1 REFER TO E0.01 FOR LEGEND, SCHEDULE AND GENERAL NOTES 2 REFER TO E5.00 FOR NORMAL POWER RISER DIAGRAMS 3 REFER TO E5.01 FOR EMERGENCY POWER RISER DIAGRAMS # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION 2 12/18/18 ADDENDUM 01 3 1/7/18 ADDENDUM 02 3 DocuSign Envelope ID: BF852761-98AC-4A3D-B58A-A23A15AF7659 1/4/2019