HomeMy WebLinkAboutE0.05ELECTRICAL PANELBOARD SCHEDULES - SHEET 2Architect Payette Associates Architects, P.C. 290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 Fax: 617-895-1002 MEP/FP Engineer Vanderweil 274 Summer Street Boston, MA 02210 Tel: 617-423-7423 Structural Engineer SGH 41 Seyong Street Building 1, Suite 500 Waltham, MA 02453 Tel: 781-907-9000 Fax: 781-907-9009 Drawing Scale Project Number Date Issued Renovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code Consultant Hastings Consulting Inc 142 Hanlon Road Hollister, MA 01746 Tel: 508-397-8417 Lighting Designer Available Light 10 Derby Square #3 Salem, MA 01970 Tel: 978-744-6800 N Cost Consultant Dharam Consulting 745 Atlantic Ave Fl 8 Boston, MA 02111 Tel: 617-913-4345 Abatement Specialist Delta 860 Hooper Rd Endwell, NY 13760 Tel: 607-231-6600 Civil Engineer T.G. Miller, P.C. 203 N. Aurora Street Ithaca, NY 14850 Tel: 607-272-6477 E0.05 29313.00 11/30/18 ELECTRICAL PANELBOARD SCHEDULES - SHEET 2 EXISTING STANDBY PANELBOARD Notes: HT = HANDLE TIE N = NONCONTINUOUS LH = LOCKING HASP DEMAND LOAD x 125% (AMPS):130 C = CONTINUOUS ST = SHUNT TRIP DEMAND LOAD (AMPS):104 K = KITCHEN A = ARC FAULT CONNECTED LOAD (AMPS):104 M = MECH/EQUIP G = GROUND FAULT 5 Ma...DEMAND LOAD (kVA):86.46 L = LIGHTING G3 = GROUND FAULT 30 Ma (EQUIP)CONNECTED LOAD (kVA):86.46 M 86.46 86.46 R = RECEPTACLE BLANK = STANDARD LOAD TYPE CONNECTED (kVA)DEMAND (kVA)LOAD TYPE KEY BREAKER TYPE KEY PANEL TOTALS PHASE AMPS:104 104 104 PHASE LOAD:28.82 28.82 28.82 41 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 42 39 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 40 37 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 38 35 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 36 33 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 34 31 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 32 29 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 30 27 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 28 25 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 26 23 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 24 21 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 22 19 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 20 17 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 18 15 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 16 13 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 14 11 14.41 0 1 20 -- SPARE -- 12 9 14.41 0 1 20 -- SPARE -- 10 7 M EF A.1 20 3 14... 0 1 20 -- SPARE -- 8 5 14.41 0 1 20 -- SPARE -- 6 3 14.41 0 1 20 -- SPARE -- 4 1 M EAHU 20 3 14... 0 1 20 -- SPARE -- 2 CKT TYPE DESCRIPTION BKR TYPE TRIP POLE A (kVA) B (kVA) C (kVA)POLE TRIP BKR TYPE DESCRIPTION TYPE CKT SHUNT TRIP:No FED FROM:MCB RATING:150A ISOLATED GROUND:No VOLTAGE:480Y/277V SSC RATING:10K MCB:Yes EQUIPMENT GROUND:Yes SURGE SUPPRESSION:No MOUNTING:Surface MLO:No NEUTRAL BUS RATING:100%FEED-THRU LUGS:No NEUTRAL BUS:Yes SUB-FEED LUGS:NoPANEL NAME:ESD-P BUS AMPS:225 PANELBOARD OPTIONS & ACCESSORIES EXISTING NORMAL PANELBOARD Notes: HT = HANDLE TIE N = NONCONTINUOUS LH = LOCKING HASP DEMAND LOAD x 125% (AMPS):9 C = CONTINUOUS ST = SHUNT TRIP DEMAND LOAD (AMPS):7 K = KITCHEN A = ARC FAULT CONNECTED LOAD (AMPS):7 M = MECH/EQUIP G = GROUND FAULT 5 Ma...DEMAND LOAD (kVA):2.52 L = LIGHTING G3 = GROUND FAULT 30 Ma (EQUIP)CONNECTED LOAD (kVA):2.52 R 2.52 2.52 R = RECEPTACLE BLANK = STANDARD LOAD TYPE CONNECTED (kVA)DEMAND (kVA)LOAD TYPE KEY BREAKER TYPE KEY PANEL TOTALS PHASE AMPS:6 9 6 PHASE LOAD:0.72 1.08 0.72 41 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 42 39 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 40 37 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 38 35 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 36 33 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 34 31 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 32 29 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 30 27 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 28 25 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 26 23 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 24 21 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 22 19 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 20 17 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 18 15 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 16 13 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 14 11 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 12 9 R LAB WRITE UP 170 20 1 0.54 0 1 20 -- SPARE -- 10 7 R LAB WRITE UP 158 20 1 0.36 0 1 20 -- SPARE -- 8 5 R LAB WRITE UP 170 20 1 0.54 0.18 1 20 R R 6 3 0.54 1 20 LAB WRITE UP 158 R 4 1 0.36 1 20 LAB WRITE UP 170A R 2 CKT TYPE DESCRIPTION BKR TYPE TRIP POLE A (kVA) B (kVA) C (kVA)POLE TRIP BKR TYPE DESCRIPTION TYPE CKT SHUNT TRIP:No FED FROM:MCB RATING:200A ISOLATED GROUND:No VOLTAGE:208Y/120V SSC RATING:22K MCB:Yes EQUIPMENT GROUND:Yes SURGE SUPPRESSION:No MOUNTING:Recessed MLO:No NEUTRAL BUS RATING:100%FEED-THRU LUGS:No NEUTRAL BUS:Yes SUB-FEED LUGS:NoPANEL NAME:LAB-1F BUS AMPS:225 PANELBOARD OPTIONS & ACCESSORIES NEW NORMAL PANELBOARD Notes: HT = HANDLE TIE N = NONCONTINUOUS LH = LOCKING HASP DEMAND LOAD x 125% (AMPS):153 C = CONTINUOUS ST = SHUNT TRIP DEMAND LOAD (AMPS):123 K = KITCHEN A = ARC FAULT CONNECTED LOAD (AMPS):228 M = MECH/EQUIP G = GROUND FAULT 5 Ma...DEMAND LOAD (kVA):101.93 L 5.13 5.13 L = LIGHTING G3 = GROUND FAULT 30 Ma (EQUIP)CONNECTED LOAD (kVA):189.2 R 184.57 97.28 R = RECEPTACLE BLANK = STANDARD LOAD TYPE CONNECTED (kVA)DEMAND (kVA)LOAD TYPE KEY BREAKER TYPE KEY PANEL TOTALS PHASE AMPS:227 226 230 PHASE LOAD:62.79 62.7 63.71 41 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 42 39 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 40 37 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 38 35 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 36 33 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 34 31 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 32 29 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 30 27 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 28 25 22... 0 1 20 -- SPARE -- 26 23 22.17 22.17 24 21 R iCVD REACTOR 100 3 22.17 22.17 22 19 -- SPARE -- 20 1 0 22.... 3 100 iCVD REACTOR R 20 17 L LIGHTING 3RD FLOOR 20 1 0.95 1.48 1 20 LIGHTING 3RD FLOOR L 18 15 L ICVD RMS 1 & 2, LAB WRITE U... 20 1 0.57 0.73 1 20 RMS 27,28,29,31,38,40 & 52 L 16 13 L OPEN RESEARCH LAB 32 20 1 1.04 0.36 1 20 OPEN LAB 32 AND LAB 31 L 14 11 8.59 0 1 20 -- SPARE -- 12 9 8.59 0 1 20 -- SPARE -- 10 7 R iCVD PUMP 20 3 8.59 0 1 20 -- SPARE -- 8 5 8.59 0 1 20 -- SPARE -- 6 3 8.59 0 1 20 -- SPARE -- 4 1 R iCVD PUMP 40 3 8.59 0 1 20 -- SPARE -- 2 CKT TYPE DESCRIPTION BKR TYPE TRIP POLE A (kVA) B (kVA) C (kVA)POLE TRIP BKR TYPE DESCRIPTION TYPE CKT SHUNT TRIP:No FED FROM:D4B MCB RATING:150A ISOLATED GROUND:No VOLTAGE:480Y/277V SSC RATING:35K MCB:Yes EQUIPMENT GROUND:Yes SURGE SUPPRESSION:No MOUNTING:Recessed MLO:No NEUTRAL BUS RATING:100%FEED-THRU LUGS:No NEUTRAL BUS:Yes SUB-FEED LUGS:NoPANEL NAME:D42 BUS AMPS:225 PANELBOARD OPTIONS & ACCESSORIES EXISTING EMERGENCY PANELBOARD Notes: HT = HANDLE TIE N = NONCONTINUOUS LH = LOCKING HASP DEMAND LOAD x 125% (AMPS):0 C = CONTINUOUS ST = SHUNT TRIP DEMAND LOAD (AMPS):0 K = KITCHEN A = ARC FAULT CONNECTED LOAD (AMPS):0 M = MECH/EQUIP G = GROUND FAULT 5 Ma...DEMAND LOAD (kVA):0.1 L = LIGHTING G3 = GROUND FAULT 30 Ma (EQUIP)CONNECTED LOAD (kVA):0.1 L 0.1 0.1 R = RECEPTACLE BLANK = STANDARD LOAD TYPE CONNECTED (kVA)DEMAND (kVA)LOAD TYPE KEY BREAKER TYPE KEY PANEL TOTALS PHASE AMPS:0 0 0 PHASE LOAD:0.1 0 0 41 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 42 39 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 40 37 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 38 35 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 36 33 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 34 31 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 32 29 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 30 27 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 28 25 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 26 23 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 24 21 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 22 19 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 20 17 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 18 15 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 16 13 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 14 11 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 12 9 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 10 7 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 8 5 -- SPARE -- 20 1 0 6 3 -- SPARE -- 20 1 0 4 1 L LIGHTING MECH ROOM 20 1 0.1 2 CKT TYPE DESCRIPTION BKR TYPE TRIP POLE A (kVA) B (kVA) C (kVA)POLE TRIP BKR TYPE DESCRIPTION TYPE CKT SHUNT TRIP:No FED FROM:MCB RATING:70A ISOLATED GROUND:No VOLTAGE:480Y/277V SSC RATING:35K MCB:Yes EQUIPMENT GROUND:Yes SURGE SUPPRESSION:No MOUNTING:Surface MLO:No NEUTRAL BUS RATING:100%FEED-THRU LUGS:No NEUTRAL BUS:Yes SUB-FEED LUGS:NoPANEL NAME:HELP-B BUS AMPS:100 PANELBOARD OPTIONS & ACCESSORIES EXISTING EMERGENCY PANELBOARD Notes: HT = HANDLE TIE N = NONCONTINUOUS LH = LOCKING HASP DEMAND LOAD x 125% (AMPS):0 C = CONTINUOUS ST = SHUNT TRIP DEMAND LOAD (AMPS):0 K = KITCHEN A = ARC FAULT CONNECTED LOAD (AMPS):0 M = MECH/EQUIP G = GROUND FAULT 5 Ma...DEMAND LOAD (kVA):0.3 L = LIGHTING G3 = GROUND FAULT 30 Ma (EQUIP)CONNECTED LOAD (kVA):0.3 L 0.3 0.3 R = RECEPTACLE BLANK = STANDARD LOAD TYPE CONNECTED (kVA)DEMAND (kVA)LOAD TYPE KEY BREAKER TYPE KEY PANEL TOTALS PHASE AMPS:1 0 0 PHASE LOAD:0.3 0 0 41 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 42 39 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 40 37 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 38 35 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 36 33 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 34 31 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 32 29 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 30 27 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 28 25 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 26 23 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 24 21 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 22 19 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 20 17 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 18 15 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 16 13 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 14 11 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 12 9 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 10 7 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 8 5 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 6 3 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 4 1 L LIGHTING 2ND FLOOR 20 1 0.3 0 1 20 -- SPARE -- 2 CKT TYPE DESCRIPTION BKR TYPE TRIP POLE A (kVA) B (kVA) C (kVA)POLE TRIP BKR TYPE DESCRIPTION TYPE CKT SHUNT TRIP:No FED FROM:MCB RATING:70A ISOLATED GROUND:No VOLTAGE:480Y/277V SSC RATING:35K MCB:Yes EQUIPMENT GROUND:Yes SURGE SUPPRESSION:No MOUNTING:Surface MLO:No NEUTRAL BUS RATING:100%FEED-THRU LUGS:No NEUTRAL BUS:Yes SUB-FEED LUGS:NoPANEL NAME:HELP-2 BUS AMPS:100 PANELBOARD OPTIONS & ACCESSORIES EXISTING EMERGENCY PANELBOARD Notes: HT = HANDLE TIE N = NONCONTINUOUS LH = LOCKING HASP DEMAND LOAD x 125% (AMPS):0 C = CONTINUOUS ST = SHUNT TRIP DEMAND LOAD (AMPS):0 K = KITCHEN A = ARC FAULT CONNECTED LOAD (AMPS):0 M = MECH/EQUIP G = GROUND FAULT 5 Ma...DEMAND LOAD (kVA):0.18 L = LIGHTING G3 = GROUND FAULT 30 Ma (EQUIP)CONNECTED LOAD (kVA):0.18 L 0.18 0.18 R = RECEPTACLE BLANK = STANDARD LOAD TYPE CONNECTED (kVA)DEMAND (kVA)LOAD TYPE KEY BREAKER TYPE KEY PANEL TOTALS PHASE AMPS:1 0 0 PHASE LOAD:0.18 0 0 41 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 42 39 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 40 37 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 38 35 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 36 33 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 34 31 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 32 29 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 30 27 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 28 25 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 26 23 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 24 21 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 22 19 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 20 17 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 18 15 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 16 13 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 14 11 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 12 9 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 10 7 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 8 5 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 6 3 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 4 1 L LIGHTING 3RD FLOOR 20 1 0.18 0 1 20 -- SPARE -- 2 CKT TYPE DESCRIPTION BKR TYPE TRIP POLE A (kVA) B (kVA) C (kVA)POLE TRIP BKR TYPE DESCRIPTION TYPE CKT SHUNT TRIP:No FED FROM:MCB RATING:70A ISOLATED GROUND:No VOLTAGE:480Y/277V SSC RATING:35K MCB:Yes EQUIPMENT GROUND:Yes SURGE SUPPRESSION:No MOUNTING:Surface MLO:No NEUTRAL BUS RATING:100%FEED-THRU LUGS:No NEUTRAL BUS:Yes SUB-FEED LUGS:NoPANEL NAME:HELP-3 BUS AMPS:100 PANELBOARD OPTIONS & ACCESSORIES EXISTING NORMAL PANELBOARD Notes: HT = HANDLE TIE N = NONCONTINUOUS LH = LOCKING HASP DEMAND LOAD x 125% (AMPS):1 C = CONTINUOUS ST = SHUNT TRIP DEMAND LOAD (AMPS):1 K = KITCHEN A = ARC FAULT CONNECTED LOAD (AMPS):1 M = MECH/EQUIP G = GROUND FAULT 5 Ma...DEMAND LOAD (kVA):0.36 L = LIGHTING G3 = GROUND FAULT 30 Ma (EQUIP)CONNECTED LOAD (kVA):0.36 R 0.36 0.36 R = RECEPTACLE BLANK = STANDARD LOAD TYPE CONNECTED (kVA)DEMAND (kVA)LOAD TYPE KEY BREAKER TYPE KEY PANEL TOTALS PHASE AMPS:3 0 0 PHASE LOAD:0.36 0 0 29 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 30 27 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 28 25 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 26 23 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 24 21 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 22 19 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 20 17 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 18 15 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 16 13 R WEATHERPROOF RECEPT. 20 1 0.18 0.18 1 20 AHU LIGHTING R 14 11 -- SPACE - RESERVED -- -- -- 0 0 -- -- -- SPACE - RESERVED -- 12 9 -- SPACE - RESERVED -- -- -- 0 0 -- -- -- SPACE - RESERVED --10 7 -- SPACE - RESERVED -- -- -- 0 0 -- -- -- SPACE - RESERVED --8 5 -- SPACE - RESERVED -- -- -- 0 0 -- -- -- SPACE - RESERVED --6 3 -- SPACE - RESERVED -- -- -- 0 0 -- -- -- SPACE - RESERVED --4 1 -- SPACE - RESERVED -- -- -- 0 0 -- -- -- SPACE - RESERVED --2 CKT TYPE DESCRIPTION BKR TYPE TRIP POLE A (kVA) B (kVA) C (kVA)POLE TRIP BKR TYPE DESCRIPTION TYPE CKT SHUNT TRIP:No FED FROM:MCB RATING:100A ISOLATED GROUND:No VOLTAGE:208Y/120V SSC RATING:22K MCB:Yes EQUIPMENT GROUND:Yes SURGE SUPPRESSION:No MOUNTING:Surface MLO:No NEUTRAL BUS RATING:100%FEED-THRU LUGS:No NEUTRAL BUS:Yes SUB-FEED LUGS:NoPANEL NAME:PENTHOUSE-N BUS AMPS:100 PANELBOARD OPTIONS & ACCESSORIES EXISTING NORMAL PANELBOARD Notes: HT = HANDLE TIE N = NONCONTINUOUS LH = LOCKING HASP DEMAND LOAD x 125% (AMPS):0 C = CONTINUOUS ST = SHUNT TRIP DEMAND LOAD (AMPS):0 K = KITCHEN A = ARC FAULT CONNECTED LOAD (AMPS):0 M = MECH/EQUIP G = GROUND FAULT 5 Ma...DEMAND LOAD (kVA):0 L = LIGHTING G3 = GROUND FAULT 30 Ma (EQUIP)CONNECTED LOAD (kVA):0 R = RECEPTACLE BLANK = STANDARD LOAD TYPE CONNECTED (kVA)DEMAND (kVA)LOAD TYPE KEY BREAKER TYPE KEY PANEL TOTALS PHASE AMPS:0 0 0 PHASE LOAD:0 0 0 41 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 42 39 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 40 37 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 38 35 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 36 33 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 34 31 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 32 29 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 30 27 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 28 25 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 26 23 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 24 21 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 22 19 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 20 17 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 18 15 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 16 13 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 14 11 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 12 9 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 10 7 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 8 5 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 6 3 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 4 1 -- SPARE -- 20 1 0 0 1 20 -- SPARE -- 2 CKT TYPE DESCRIPTION BKR TYPE TRIP POLE A (kVA) B (kVA) C (kVA)POLE TRIP BKR TYPE DESCRIPTION TYPE CKT SHUNT TRIP:No FED FROM:MCB RATING:200A ISOLATED GROUND:No VOLTAGE:208Y/120V SSC RATING:22K MCB:Yes EQUIPMENT GROUND:Yes SURGE SUPPRESSION:No MOUNTING:Recessed MLO:No NEUTRAL BUS RATING:100%FEED-THRU LUGS:No NEUTRAL BUS:Yes SUB-FEED LUGS:NoPANEL NAME:LAB-3F BUS AMPS:225 PANELBOARD OPTIONS & ACCESSORIES ELECTRICAL GENERAL NOTES -PANELBOARDS 1. EXISTING PANELBOARD LAB-3F IS SURFACE MOUNTED TO BE REMOVED, RELOCATED AND REINSTALLED AS RECESSED MOUNTED. ELECTRICAL SHEET NOTES - PANELBOARDS 1 PANELBOARD SCHEDULES ARE BEING ISSUED WITH CONSTRUCTION DOCUMENTS FOR USE BY THE CONTRACTOR DURING CONSTRUCTION. AFTER ISSUANCE OF CONSTRUCTION DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING UPDATED PANEL SCHEDULES THAT REFLECT INSTALLED CONDITIONS, IN ACCORDANCE WITH THE SPECIFICATION. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR ISSUING SCHEDULES DURING THE CONSTRUCTION ADMINISTRATION PROCESS UNLESS DEEMED NECESSARY BY THE ENGINEER. # DATE DESCRIPTION 1 11/30/18 ISSUED FOR CONSTRUCTION 2 12/18/18 ADDENDUM 01 3 1/7/18 ADDENDUM 02 EXISTING OPTIONAL STANDBY PANELBOARD Notes: HT = HANDLE TIE N = NONCONTINUOUS LH = LOCKING HASP DEMAND LOAD x 125% (AMPS):6 C = CONTINUOUS ST = SHUNT TRIP DEMAND LOAD (AMPS):5 K = KITCHEN A = ARC FAULT CONNECTED LOAD (AMPS):5 M = MECH/EQUIP G = GROUND FAULT 5 Ma...DEMAND LOAD (kVA):3.99 L = LIGHTING G3 = GROUND FAULT 30 Ma (EQUIP)CONNECTED LOAD (kVA):3.99 M 3.99 3.99 R = RECEPTACLE BLANK = STANDARD LOAD TYPE CONNECTED (kVA)DEMAND (kVA)LOAD TYPE KEY BREAKER TYPE KEY PANEL TOTALS PHASE AMPS:5 5 5 PHASE LOAD:1.33 1.33 1.33 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 1.33 6 3 1.33 4 1 M SP-1 20 3 1.33 2 CKT TYPE DESCRIPTION BKR TYPE TRIP POLE A (kVA) B (kVA) C (kVA)POLE TRIP BKR TYPE DESCRIPTION TYPE CKT SHUNT TRIP:No FED FROM:MCB RATING:–ISOLATED GROUND:No VOLTAGE:480Y/277V SSC RATING:35K MCB:No EQUIPMENT GROUND:Yes SURGE SUPPRESSION:No MOUNTING:Surface MLO:Yes NEUTRAL BUS RATING:100%FEED-THRU LUGS:No NEUTRAL BUS:Yes SUB-FEED LUGS:NoPANEL NAME:HEPP-B BUS AMPS:100 PANELBOARD OPTIONS & ACCESSORIES 3 DocuSign Envelope ID: BF852761-98AC-4A3D-B58A-A23A15AF7659 1/4/2019