Loading...
HomeMy WebLinkAboutA9.00PARTITION TYPESUNDERSIDE OF STRUCTURE4 7/8" (3 5/8" STUD)NO FIRE RESISTANCE RATINGSTC = 40-444 7/8" (3 5/8" STUD)1 HOUR RATING - UL# U465STC = 40-447 1/4" (6" STUD)NO FIRE RESISTANCE RATINGSTC = 40-447 1/4" (6" STUD)1 HOUR FIRE - UL# U465STC = 40-44HEADCEILINGPLANBASEPROVIDE CASING BEAD WHERE EXPOSED TO VIEWCEILING RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULEDMETAL STUDS5/8" GYPSUM BOARD,TYPE X AT A1 AND A3 PARTITIONS(7 1/4")4 7/8"LIMITING HEIGHT 14'-10"LIMITING HEIGHT 14'-10"LIMITING HEIGHT 21'-6"LIMITING HEIGHT 21'-6"TOP OF SLABFLOOR RUNNERSEALANTAA1A2A34 7/8" (3 5/8" STUD)NO FIRE RESISTANCE RATINGSTC = 45-494 7/8" (3 5/8" STUD)1 HOUR RATING - UL# U465STC = 45-497 1/4" (6" STUD)NO FIRE RESISTANCE RATINGSTC = 45-497 1/4" (6" STUD)1 HOUR FIRE - UL# U465STC = 45-49PROVIDE CASING BEAD WHERE EXPOSED TO VIEWCEILING RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULED5/8" GYPSUM BOARD,TYPE X AT B1 AND B3 PARTITIONS(7 1/4")4 7/8"3 1/2" SOUND ATTENUATIONINSULATIONMETAL STUDSHEADCEILINGPLANBASETOP OF SLABFLOOR RUNNERSEALANTLIMITING HEIGHT 14'-10"LIMITING HEIGHT 14'-10"LIMITING HEIGHT 21'-6"LIMITING HEIGHT 21'-6"UNDERSIDE OF STRUCTUREBB1B2B35 1/2" UNBALANCED (3 5/8" STUD)NO FIRE RESISTANCE RATINGSTC = 50-545 1/2" UNBALANCED (3 5/8" STUD)1 HOUR RATING - UL# U419STC = 50-547 7/8" UNBALANCED (6" STUD)NO FIRE RESISTANCE RATINGSTC = 50-547 7/8" UNBALANCED (6" STUD)1 HOUR RATING - UL# U419STC = 50-54PROVIDE CASING BEAD WHERE EXPOSED TO VIEWCEILING RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULED5/8" GYPSUM BOARD,TYPE X AT C1 AND C3 PARTITIONS(7 7/8")5 1/2"METAL STUDSHEADCEILINGPLANBASE3 1/2" SOUND ATTENUATIONINSULATIONTOP OF SLABFLOOR RUNNERSEALANTLIMITING HEIGHT 14'-10"LIMITING HEIGHT 14'-10"LIMITING HEIGHT 21'-6"LIMITING HEIGHT 21'-6"UNDERSIDE OF STRUCTURECC1C2C36 1/8" (3 5/8" STUD)NO FIRE RESISTANCE RATINGSTC = 55-59PROVIDE CASING BEAD WHERE EXPOSED TO VIEWCEILING RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULED5/8" GYPSUM BOARD, DOUBLE LAYER EACH SIDETYPE X AT D1 AND D3 PARTITIONS(8 1/2")6 1/8"6 1/8" (3 5/8" STUD)2 HOUR FIRE - UL# U411STC = 55-598 1/2" (6" STUD)NO FIRE RESISTANCE RATINGSTC = 55-598 1/2" (6" STUD)2 HOUR FIRE - UL# U411STC = 55-59METAL STUDSHEADCEILINGPLANBASE3 1/2" SOUND ATTENUATIONINSULATIONTOP OF SLABFLOOR RUNNERSEALANTLIMITING HEIGHT 14'-10"LIMITING HEIGHT 14'-10"LIMITING HEIGHT 21'-6"LIMITING HEIGHT 21'-6"UNDERSIDE OF STRUCTUREDD1D2D3CHASE WALL (2 1/2" STUD)NO FIRE RESISTANCE RATINGSTC = 50-54PROVIDE CASING BEAD WHERE EXPOSED TO VIEWCEILING RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULEDMETAL STUDS5/8" GYPSUM BOARD, 1 OR 2 LAYERS EACH SIDE, TYPE X AT FIRE RATED PARTITIONSFLOOR RUNNERTOP OF SLABDEPTH INDICATED IN PLAN (10 3/4" MIN)CHASE WALL (2 1/2" STUD)1 HOUR FIRE - UL# U420STC = 50-54CHASE WALL (2 1/2" STUD)2 HOUR FIRE - UL# U420STC = 55-599 1/2" MIN.INTERNAL BRACING: BRACE EACHSTUD 4'-0" O.C. MAX VERTICALLYWITH STEEL RUNNERSFUTURE2 1/2" SOUND ATTENUATIONINSULATIONHEADCEILINGPLANBASESEALANTUNDERSIDE OF STRUCTUREGG1G2G3UNDERSIDE OF STRUCTURE1 1/2" INTERIOR FURRED WALL (7/8" RIGID FURRING CHANNEL)NO FIRE RESISTANCE RATINGNO ACOUSTIC RATING1 5/8" EXTERIOR FURRED WALL (1" Z-FURRING CHANNEL)NO FIRE RESISTANCE RATINGNO ACOUSTIC RATINGPROVIDE CASING BEAD WHERE EXPOSED TO VIEWCEILING RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULED1" THERMAL INSULATION - H1 ONLYBASE CONSTRUCTION, NEW OR EXISTINGTOP OF SLAB3" MINRIGID FURRING CHANNEL ORZ-SHAPED FURRING CHANNELEXTEND GYPSUM BOARD TO UNDERSIDE OF STRUCTURE IF NO CEILING SCHEDULEDVAPOR RETARDER - H1 ONLYRIGID FURRING CHANNEL ORZ-FURRING CHANNEL5/8" GYPSUM BOARDHEADCEILINGPLANBASEFUTUREFUTURE1 1/2" (1 5/8")HH1H2H3UNDERSIDE OF STRUCTURE3 1/8" FURRED WALL (2 1/2" STUD)NO FIRE RESISTANCE RATINGNO ACOUSTIC RATINGPROVIDE CASING BEAD WHERE EXPOSED TO VIEWCEILING RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULEDMETAL STUDS5/8" GYPSUM BOARDFLOOR RUNNERTOP OF SLAB4 1/4" FURRED WALL (3 5/8" STUD)NO FIRE RESISTANCE RATINGNO ACOUSTIC RATINGFURRING BRACKETS3" MIN1/4" MINIMUM CLEARANCEEXTEND GYPSUM BOARD TO UNDERSIDE OF STRUCTURE IFNO CEILING SCHEDULEDVARIES6 5/8" FURRED WALL (6" STUD)NO FIRE RESISTANCE RATINGNO ACOUSTIC RATING2 1/4" FURRED WALL (1 5/8" STUD)NO FIRE RESISTANCE RATINGNO ACOUSTIC RATINGHEADCEILINGPLANBASEJJ1J2J3UNDERSIDE OF STRUCTURE4 1/4" SINGLE SIDED (3 5/8" STUD)NO FIRE RESISTANCE RATINGSTC = <30PROVIDE CASING BEAD WHERE EXPOSED TO VIEWCEILING RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULEDMETAL STUDS5/8" GYPSUM BOARD, 2 LAYERS OF TYPE X AT K1 AND K3 PARTITIONSLIMITING HEIGHT 13'-6"LIMITING HEIGHT 13'-6"LIMITING HEIGHT 20'-0"LIMITING HEIGHT 20'-0"4 7/8" SINGLE SIDED (3 5/8" STUD)1 HOUR RATING - UL# V497STC = 30-356 5/8" SINGLE SIDED (6" STUD)NO FIRE RESISTANCE RATINGSTC = <307 1/4" SINGLE SIDED (6" STUD)1 HOUR RATING - UL# V497STC = 30-35VARIES3 1/2" SOUND ATTENUATION INSULATION AT K1 AND K3 PARTITIONS ONLYHEADCEILINGPLANBASETOP OF SLABFLOOR RUNNERSEALANTKK1K2K3HEADCEILINGPLANBASESHAFT WALL (2 1/2" STUD)1 HOUR RATING - UL# U415STC = 35-39PROVIDE CASING BEAD WHERE EXPOSED TO VIEWSHAFT-WALL RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULEDSHAFT-WALL STUDS5/8" TYPE X GYPSUM BOARDSHAFT-WALL RUNNERTOP OF SLAB(4 5/8")3 1/8"LIMITING HEIGHT 10'-10"SHAFT WALL (2 1/2" STUD)1 HOUR RATING - UL# U415STC = 40-45LIMITING HEIGHT 10'-10"SHAFT WALL (4" STUD)1 HOUR RATING - UL# U415STC = 35-39LIMITING HEIGHT 15'-3"SHAFT WALL (4" STUD)1 HOUR RATING - UL# U415STC = 40-45LIMITING HEIGHT 15'-3"1" GYPSUM LINER PANEL1/2" SOUND ATTENUATION INSULATION AT N1 & N3 PARTITIONS ONLYSEALANTUNDERSIDE OF STRUCTURENN1N2N3SHAFT WALL (2 1/2" STUD)2 HOUR RATING - UL# U415STC = 40-44PROVIDE CASING BEAD WHERE EXPOSED TO VIEWSHAFT-WALL RUNNERDEFLECTION ALLOWANCESHAFT-WALL STUDS5/8" TYPE X GYPSUM BOARD,DOUBLE LAYER(5 1/4")3 3/4"LIMITING HEIGHT 11'-7"SHAFT WALL (2 1/2" STUD)2 HOUR RATING - UL# U415STC = 45-49LIMITING HEIGHT 11'-7"SHAFT WALL (4" STUD)2 HOUR RATING - UL# U415STC = 40-44LIMITING HEIGHT 16'-2"SHAFT WALL (4" STUD)2 HOUR RATING - UL# U415STC = 45-49LIMITING HEIGHT 16'-2"1" GYPSUM LINER PANEL1/2" SOUND ATTENUATION INSULATION AT P1 & P3 PARTITIONS ONLYHEADCEILINGPLANBASESUSPENDED CEILING WHERE SCHEDULEDSHAFT-WALL RUNNERTOP OF SLABSEALANTUNDERSIDE OF STRUCTUREPP1P2P3HEADCEILINGPLANBASEUNDERSIDE OF STRUCTURE6" NOMINAL CONCRETE MASONRY UNITNO FIRE RESISTANCE RATINGSTC = 45FIRE SAFING OR COMPRESSIBLE FILLERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULEDCONCRETE MASONRY UNITS4" HIGH CONCRETE MASONRY UNITS STARTER COURSE, IF APPLICABLELIMITING HEIGHT 18'-0"LIMITING HEIGHT 18'-0"LIMITING HEIGHT 18'-0"6" NOMINAL CONCRETE MASONRY UNIT1 HOUR FIRE - UL# U906STC = 456" NOMINAL CONCRETE MASONRY UNIT2 HOUR FIRE - UL# U906STC = 45STAGGERED STEELRESTRAINT ANGLES5 5/8"TOP OF SLABSEALANTUU1U2HEADCEILINGPLANBASE8" NOMINAL CONCRETE MASONRY UNITNO FIRE RESISTANCE RATINGSTC = 47LIMITING HEIGHT 24'-0"LIMITING HEIGHT 24'-0"LIMITING HEIGHT 24'-0"8" NOMINAL CONCRETE MASONRY UNIT1 HOUR FIRE - UL# U905STC = 478" NOMINAL CONCRETE MASONRY UNIT2 HOUR FIRE - UL# U905STC = 477 5/8"LIMITING HEIGHT 24'-0"8" NOMINAL CONCRETE MASONRY UNIT3 HOUR FIRE - UL# U905STC = 47SUSPENDED CEILING WHERE SCHEDULEDCONCRETE MASONRY UNITSTOP OF SLABSEALANTUNDERSIDE OF STRUCTUREFIRE SAFING OR COMPRESSIBLE FILLERDEFLECTION ALLOWANCE4" HIGH CONCRETE MASONRY UNITS STARTER COURSE, IF APPLICABLESTAGGERED STEELRESTRAINT ANGLESVV1V2V3UNDERSIDE OF STRUCTURE4 1/4" SINGLE SIDED (3 5/8" STUD)NO FIRE RESISTANCE RATINGSTC = <30PROVIDE CASING BEAD WHERE EXPOSED TO VIEWCEILING RUNNERDEFLECTION ALLOWANCESUSPENDED CEILING WHERE SCHEDULEDMETAL STUDS5/8" GYPSUM BOARD, 2 LAYERS OF TYPE X AT L1 AND L3 PARTITIONSLIMITING HEIGHT 13'-6"LIMITING HEIGHT 13'-6"LIMITING HEIGHT 20'-0"LIMITING HEIGHT 20'-0"4 7/8" SINGLE SIDED (3 5/8" STUD)1 HOUR RATING - UL# V497STC = 30-356 5/8" SINGLE SIDED (6" STUD)NO FIRE RESISTANCE RATINGSTC = <307 1/4" SINGLE SIDED (6" STUD)1 HOUR RATING - UL# V497STC = 30-35VARIES2 1/2" SPRAY-APPLIED INSULATIONHEADCEILINGPLANBASETOP OF SLABFLOOR RUNNERSEALANTLL1L2L3BASE CONSTRUCTION, NEW OR EXISTINGArchitectPayette Associates Architects, P.C.290 Congress Street, Fifth FloorBoston, MA 02210-1005Tel: 617-895-1000Fax: 617-895-1002MEP/FP EngineerVanderweil274 Summer StreetBoston, MA 02210Tel: 617-423-7423Structural EngineerSGH41 Seyong StreetBuilding 1, Suite 500Waltham, MA 02453Tel: 781-907-9000Fax: 781-907-9009Drawing ScaleProject NumberDate IssuedRenovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code ConsultantHastings Consulting Inc142 Hanlon RoadHollister, MA 01746Tel: 508-397-8417Lighting DesignerAvailable Light10 Derby Square #3Salem, MA 01970Tel: 978-744-6800NCost ConsultantDharam Consulting745 Atlantic Ave Fl 8Boston, MA 02111Tel: 617-913-4345Abatement SpecialistDelta860 Hooper RdEndwell, NY 13760Tel: 607-231-6600Civil EngineerT.G. Miller, P.C.203 N. Aurora StreetIthaca, NY 14850Tel: 607-272-6477 1 1/2" = 1'-0"A9.0020758.0011/30/2018PARTITION TYPESSCALE: 1 1/2" = 1'-0"AGYPSUM BOARD PARTITION - TYPICAL, NO SOUND ATTENUATIONSCALE: 1 1/2" = 1'-0"BGYPSUM BOARD PARTITION - TYPICAL, SOUND ATTENUATIONSCALE: 1 1/2" = 1'-0"CGYPSUM BOARD PARTITION - UNBALANCEDSCALE: 1 1/2" = 1'-0"DGYPSUM BOARD PARTITION - DOUBLESCALE: 1 1/2" = 1'-0"GCHASE WALL PARTITIONSCALE: 1 1/2" = 1'-0"HGYPSUM BOARD PARTITION - CHANNEL-FURREDSCALE: 1 1/2" = 1'-0"JGYPSUM BOARD PARTITION - STUD-FURREDSCALE: 1 1/2" = 1'-0"KGYPSUM BOARD PARTITION - SINGLE-SIDEDSCALE: 1 1/2" = 1'-0"NSHAFT WALL PARTITION - 1 HOURSCALE: 1 1/2" = 1'-0"PSHAFT WALL PARTITION - 2 HOURSCALE: 1 1/2" = 1'-0"U6" NOMINAL CONCRETE MASONRY UNIT PARTITIONSCALE: 1 1/2" = 1'-0"V8" NOMINAL CONCRETE MASONRY UNIT PARTITIONSCALE: 1 1/2" = 1'-0"LGYPSUM BOARD PARTITION - SPRAY-INSULATED# DATE DESCRIPTION1 11/30/18 ISSUED FOR CONSTRUCTION