Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A6.20LEVEL 2 - CEILING PLAN
22113346677885QPRSTOU9S1R14AQ15.14' - 0"19' - 0"20' - 0"20' - 0"19' - 0"1' - 0"10' - 10"15' - 5 1/2"25' - 0"10' - 10"15' - 5 1/2"20' - 0"15' - 0"20' - 0"20' - 0"10' - 0"20' - 0"20' - 0"NEW GYPSUM BOARD VERTICAL FASCIA8' - 6"CHAPC29' - 6"CHBAFFLE8' - 6"CHGYPEXISTING ACOUSTIC TILE CEILING. REPLACE OR PATCH AS NEEDED TO MATCH EXISTING.9' - 6"CHBAFFLE8' - 6"CHGYP8' - 6"CHGYP8' - 6"CHGYP8' - 6"CHAPC28' - 6"CHAPC28' - 6"CHAPC28' - 6"CHGYP8' - 6"CHGYP8' - 6"CHAPC1EXPOSED TO STRUCTURE ABOVE. PAINT STRUCTURE AND ALL UTILITIESEXPOSED TO STRUCTURE ABOVE. PAINT STRUCTURE AND ALL UTILITIESSLOTTED CHANNEL FRAMING SUPPORT SYSTEM, PAINTED, TYP. 8' - 6"CHGYP8' - 2"CHAPC1LPA-10LPA-10LPA-10LPA-10LPA-10LPA-10LPA-10LPA-10PAPAPAPAPAPAPAPAPAPAPAPAPAPA PA PA PA PAPAPAPAPALINEAR WALL WASH FIXTUREEXPOSED TO STRUCTURE ABOVE. PAINT STRUCTURE AND ALL UTILITIES8' - 6"CHAPC2RLA-108' - 6"CHGYP8' - 6"CHAPC2LINEAR WALL WASH FIXTURE8' - 6"CHGYPLINEAR WALL WASH FIXTURERLC-10PAPAPAPAPALPBLPBLPBDWADWADWARLC-8RLC-8RLC-8RLC-8RLC-8RLC-8DWBRARARLA-12RLA-12EQEQEQFOSRLA-12RLA-12EQEQFOSEQEQOSEQEQOSFRAEQEQEQEQRLA-10RLA-104' - 7 3/8"4"4' - 7"6"4' - 7"4"4' - 7"6"4' - 7"4"4' - 10"3 3/4"4'-2 1/4"2'-11 3/4"2'-11 3/4"2'-11 3/4"3'-5"3'-5"3'-5"3'-3 3/4"3'-3 3/4"3'-3 3/4"3'-3"3'-3"3'-3"3'-4"3'-4"3'-4"3'-2 3/4"3'-2 3/4"3'-2 3/4"3'-0 3/4"3'-0 3/4"3'-0 3/4"4'-2 1/4"3 3/4"2 3/4"2'-11 3/4"2'-11 3/4"2'-11 3/4"2'-11 3/4"EQEQEQEQEQEQRLA-8EQEQEQ2'-0"EQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQ7'-2 1/4"4'-2"6"8'-2"4'-11 3/4"EQEQEQEQEQEQ8A9.118A9.11EXISTING MANUAL ROLLER SHADES TO REMAIN, TYPICAL.ACOUSTICAL PANEL BETWEEN ALL COFFERS IN WRITE UP AREAS. TYP.ACOUSTICAL PANEL BETWEEN ALL COFFERS IN WRITE UP AREAS. TYP.10A9.011HR FIRE RATED SOFFIT2'-0"2'-0"8' - 6"CHGYPNEW GYPSUM BOARD SOFFIT2'-0"7' - 2"GYPSUM SOFFIT.ACOUSTICAL PANEL CEILING, 2 X 4 PANELS (APC 2), & WITH MYLAR COATING (APC 3).ACOUSTICAL PANEL CEILING, 2 X 2 PANELS (APC 1). LINEAR DIRECT/INDIRECT PENDANT , OCCUPANCY & DAYLIGHT SENSOR CONTROLLED.LINEAR WALL WASH PENDANT.PENDANT DOWNLIGHT FIXTURE.REFLECTED CEILING PLAN LEGENDSPRINKLER HEAD.FIRE ALARM.RECESSED DOWNLIGHT FIXTURE.PAINTED WOOD BAFFLE CEILING RECESSED LINEAR DOWNLIGHT.OCCUPANCY SENSOR.FOSREFLECTED CEILING PLAN GENERAL NOTESA. CONTRACT LIMIT LINES SHALL BE WHERE INDICATED ON THE DRAWINGS. HOWEVER, IN ORDER TO COMPLETE OR FACILITATE INDICATED WORK, CONTRACTOR MAY BE REQUIRED TO CARRY OUT WORK ADJACENT TO, BUT OUTSIDE INDICATED LIMITS.B. ALL EXPOSED CEILING EQUIPMENT AND EXPOSED STRUCTURE TO BE PAINTED.C. LIGHTING FOR BUILDING SERVICES SPACES SHOWN IN ELECTRICAL DRAWINGS.D. CEILING IS OPEN TO STRUCTURE UNLESS OTHERWISE NOTED.E. ALL ACOUSTIC PANEL CEILING LAYOUTS TO BE CENTERED ON ROOM UNLESS OTHERWISE NOTED.ArchitectPayette Associates Architects, P.C.290 Congress Street, Fifth FloorBoston, MA 02210-1005Tel: 617-895-1000Fax: 617-895-1002MEP/FP EngineerVanderweil274 Summer StreetBoston, MA 02210Tel: 617-423-7423Structural EngineerSGH41 Seyong StreetBuilding 1, Suite 500Waltham, MA 02453Tel: 781-907-9000Fax: 781-907-9009Drawing ScaleProject NumberDate IssuedRenovation of Olin Hall for Chemical and Biomolecular Engineering - Phase 1 Code ConsultantHastings Consulting Inc142 Hanlon RoadHollister, MA 01746Tel: 508-397-8417Lighting DesignerAvailable Light10 Derby Square #3Salem, MA 01970Tel: 978-744-6800NCost ConsultantDharam Consulting745 Atlantic Ave Fl 8Boston, MA 02111Tel: 617-913-4345Abatement SpecialistDelta860 Hooper RdEndwell, NY 13760Tel: 607-231-6600Civil EngineerT.G. Miller, P.C.203 N. Aurora StreetIthaca, NY 14850Tel: 607-272-6477As indicatedA6.2020758.0011/30/2018LEVEL 2 - CEILING PLAN# DATE DESCRIPTION1 11/30/18 ISSUED FOR CONSTRUCTION2 12/18/18 ADDENDUM 01