HomeMy WebLinkAbout815 S Aurora St Bldg A and B_Mechanical_Revised Permit DrawingsM C T S EXHAUST GRILLE RETURN GRILLE SUPPLY DIFFUSER VOLUME DAMPER FIRE DAMPER CONTROL DAMPER LEGEND CONNECT TO EXISTING MASTER THERMOSTAT TIME CLOCK DEMOLISHED EXISTING TO REMAIN THERMOSTAT CO2 SENSOR/PTL CONTROLLER FLEX DUCT Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/8" = 1'-0"8/20/2021 12:53:54 PMM0.00 Notes STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 14850A.HEAT PUMP SYSTEMS: 1.During unoccupied periods as determined by 7 day programmable thermostat, the system shall be set back to adjustable setpoint temperatures. 2.During occupied periods as determined by 7 day programmable thermostat, the system shall respond to setpoint temperatures. Each fan coil shall have a thermostat for heating and cooling setpoints. The unit shall remain on until setpoint is reached. 3.The heat pump system is to be the primary heating/cooling system to reach setpoint temperatures. A.In heating mode, the thermostat shall call for heat from the fan coil/heat pump and they shall remain on until satisfying setpoint temperature. If the space temperature cannot be satisfied and the temperature drops 3 degrees below setpoint temperature, the 2nd stage heat 24 Volt DC output shall energize the electric resistance heat relays. The electric heat will be integral to the fan coil. B.In cooling mode, the thermostat shall call for cooling from the fan coil/heat pump and they shall remain on until satisfying setpoint temperature. In cooling mode, the electric resistance heat shall be locked out. B.EXHAUST FANS: 1.EF-1 Bathroom exhaust fan; The bathroom exhaust fan shall run continuously. In three bedroom units the fan shall run at 65 CFM,in two bedroom units the fan shall run at 50 CFM, in one bedroom units the fan shall run at 35 CFM. . 2.EF-2 Fire pump room fan; The corridor ventilation fan shall run continuously at 50 CFM. 3.EF-1 Corridor bathroom exhaust fan; The bathroom exhaust fan shall turn on and run at 50 CFM when occupancy is sensed by a wall mounted occupancy sensor. When occupancy is no longer sensed, the fan shall turn off. C. ELECTRIC WALL HEATER & BASEBOARD HEATERS 1.In the stairwells and corridors, there shall be an internal thermostat (set to 68 degrees F) with lockout that is to control setpoint temperatures. Upon a call for heat, the heater shall turn on and remain on. Upon setpoint being satisfied, the heater shall turn off and remain off. Electric baseboard heaters shall have a unit mounted thermostat (set to 68 degrees F). Upon a call for heat, the heater shall turn on and remain on. Upon setpoint being satisfied, the heater shall turn off and remain off. D.ENERGY RECOVERY VENTILATOR SYSTEMS: 1. ERV-1 (Gym/Game room & 4th floor & Lounge); Once enabled, the exhaust and outdoor air motorized dampers shall be open 100% and supply and exhaust fans shall run. The unit shall be enabled by a wall mounted CO2 sensor setpoint reading over 700 ppm (adjustable) and a ceiling mounted occupancy sensor (located in each bathroom and one in the fitness center). Once the CO2 setpoint and occupancy sensors are satisfied, supply and exhaust fans shall stop and the exhaust and outdoor air motorized dampers shall be closed. The unit shall have an electric resistance duct heater that the internal SRC controller shall control based on supply air temperature. 2. ERV-1 (Corridors); The corridor ERV shall run continuously. The unit shall have an electric resistance duct heater that the internal SRC controller shall control based on supply air temperature. 3. ERV-2; Once enabled, the exhaust and outdoor air motorized dampers shall be open 100% and supply and exhaust fans shall run. The unit shall be enabled by a wall mounted CO2 sensor setpoint reading over 700 ppm (adjustable) and a ceiling mounted occupancy sensor. Once the CO2 setpoint and occupancy sensors are satisfied, supply and exhaust fans shall stop and the exhaust and outdoor air motorized dampers shall be closed. The unit shall have an electric resistance duct heater that the internal SRC controller shall control based on supply air temperature. SEQUENCE OF OPERATIONS Part 1 -GENERAL 1.1 SUBMITTALS A.Provide electronic (pdf) submittals of the following: 1.Equipment 2.Equipment pads 3.Lineset tubing and insulation 4.Rigid and flexible duct 5.Duct insulation 6.Registers, grilles, louvers, wall caps, radiation dampers 7.Ductwork shop drawings B.Testing and Balancing report air-side (all supply/return/ventilation/exhaust registers). AABC or NEBB qualified balancer. C.Closeout 1.Operation and Maintenance Manual 2.As-Built drawings PART 2 -PRODUCTS 2.1 HEATING AND COOLING SPLIT SYSTEM A.System shall be a variable refrigerant flow series DX split type air conditioner using multiple indoor units of varying type and size, an inverter driven outdoor condensing unit and a direct digital control system to ensure an efficiently controlled, operated and engineered system. B.There shall be a 5 year warranty on the compressor and 1 year plus extended on all other parts. A certified contractor shall install the system to receive the extended warranty. C.Refrigerant circuit 1.The refrigerant circuit shall include manufacturer supplied Y-branches or Header fittings to connect to single or multiple (ducted, non-ducted or mixed) indoor units to effectively and evenly distribute refrigerant throughout the VRF system. 2.All field installed refrigerant pipes between outdoor unit and Y-branch or Header and from Y-branch or Header to indoor units shall be field provided. 3.Factory installed microprocessor controls in the outdoor unit, and indoor units shall perform functions to efficiently operate the VRF system. 4.Communication between components shall be provided via a field provided and installed 18 AWG shielded wire pair and terminated in a RS485 daisy chain configuration. 5.Outdoor Unit shall be capable of continuous operation between the following outdoor ambient range. Operation outside of these conditions is possible and may involve non-continuous operations. a.Cooling: 23°F DB to 122°F DB b.Heating: -4°F WB to 61°F WB 6.The system shall be capable of operating at an elevation of at lease 164 feet above or 131 feet below the indoor units. 7. All field provided piping shall be de-hydraded ACR copper pipe. Other pipe materials shall not be allowed. 8. All refrigerant piping shall be insulated with 1" insulation. 2.2 FAN COIL 1.The fan coil unit shall be designed to operate in the vertical (upflow) configuration or horizontal (left) end discharge. 2.Unit shall be equipped with factory installed temperature thermistors for: a.Return air 1.Refrigerant entering coil 2.Refrigerant leaving coil 3.Unit shall have the following functions as standard: a.Self-diagnostic function b.Auto addressing 1.Auto restart function d.Auto changeover function (Heat Recovery system only) 1.Auto operation function 2.Child lock function 3.Forced operation 4.Dual thermistor control 5.Sleep mode 6.External static pressure (ESP) control 7.Dual setpoint control 8.Multiple aux heater applications 9.Filter life and power consumption display 2.3 DUCTWORK A.Metallic ductwork 1.Sheet metal per SMACNA HVAC Duct Construction Standards -Metal and Flexible, low pressure requirements. a.Round ducts 1)12" or less: 30 gauge 2)Over 12": 26 gauge b.Rectangular ducts 1)36" or less: 30 gauge 2)Over 36": 26 gauge c.Fabricate round and rectangular duct hangers and supports from materials and methods outlined in SMACNA -Low Pressure Duct Construction Standards, 5th Edition. d.All ductwork is to be rigid. e.Duct sizing -Pressure drop shall be no more than 0.1" SP/100 feet of duct. B.Insulation 1.All fiberglass products shall be fornaldehyde-free. 2.Duct insulation in conditioned spaces: Supply R-5; Return none. 3.Duct insulation in unconditioned spaces: Supply and Return R-8. 4. Duct insulation for ERV; Exhaust duct and outdoor air intake duct R-8. C.Duct sealant options: a.RCD Corp Mastic #6, Hardcast Iron-Grip 601, or equal, with fiberglass mesh tape, UL 181. b.Automated aerosolized sealant: Aeroseal or approved equal. D.Registers and grilles 1.Wall supply registers: Hart & Cooley with opposed blade damper. 2.Wall return grilles: Hart & Cooley 3.Exterior louvers: Alumininum, drainable, depth to coordinate with wall construction. 4.Provide register and louver frame styles compatible with mounting surface. 5.All registers types, colors, and locations are to be coordinated with architect. E.Ceiling Radiation Dampers 1. Greenheck CRD-1 or approved equal. 2. Install as per manufacturers instructions F. Dryer Duct 1.30 ga. galv or aluminum, 4"ø rigid metal or 31/4x10 wallstacks to roof w/gooseneck and backdraft damper. 2.Makeup air required where dryer exceeds 200 cfm. 3.Exhaust ducts for domestic clothes dryers shall have a smooth interior finish. The entire exhaust system shall be supported and secured in place. The male end of the duct at overlapped duct joints shall extend in the direction of airflow. Clothes dryer transition ducts used to connect the appliance to the exhaust duct system shall be metal and limited to a single length not to exceed 8 feet in length and shall be listed and labeled for the application. Transition ducts shall not be concealed within construction. 4.Provide clean out at all vertical sections of dryer exhuast duct. 5.Seal all penetrations with non-combustible material. 2.4 MECHANICAL IDENTIFICATION A.Plastic Nameplates: All equipment is to have laminated three layer black plastic with engraved white letters. Tag size minimum 1½”square. B.Plastic Tape Pipe Markers: All ducts and pipes are to have flexible, vinyl film tape with pressure sensitive adhesive backing and printed markings. Green background with white letters. 2.5 CONTROLS A.Provide all controls as required on the schedules and to implement Sequence of Operation described on this sheet. PART 3 -EXECUTION 3.1 INSTALLATION A.General 1.Install all equipment per manufacturer's instructions and standard trade practices. Set units level and plumb. Provide vibration isolation in between the condensing unit and the base stand. 2.All equipment shall have vibration isolation incorporated into the support system. 3.Provide clearances as specified by the manufacturer. 4.Provide access panels for concealed equipment, valves, dampers. 5.Coordinate locations of all equipment with architectural drawing. 6.Provide electric power, per NEC. Verify compatibility with equipment power characteristics. Provide new circuit breakers as required. Label breakers with neat, permanent markings. 7.All work is to be done in accordance with 2015 Uniform Code with 2016 NYS supplements. B.Refrigerant Piping 1.Size and insulate refrigerant piping per manufacturer's instructions. Provide UV protectant coating for exposed exterior insulation. Comply with ASHRAE 15. Exterior pipes shall be encased in a PVC pipe cover. Referigerant piping on roof shall be supported every 4'. Perform Triple Leak and Pressure Test as per manufacturer’s instruction including checking all connections for leaks by applying a bubble solution to all joints. Document the locations of any leaks found and fix leaks and retest as per manufacturer’s instructions. Once Leak and Pressure Test is completed perform Triple Evacuation Procedure as per the manufacturer’s instructions. Once the system has been properly evacuated confirm the necessity of additional Refrigerant Trim Charge as per the manufacturer’s instructions and engineering documents. Document any refrigerant added for each unit and final refrigerant charge. If there are joints between the indoor and outdoor units other than at the units, document on as built drawings including piping riser diagram so that the joint can be located post-construction. Provide documentation for the above testing including the name of the person performing the test, day/time, results of any leaks that needed to be fixed. Notify engineer at least 48 hours prior to the testing. C.Ductwork 1.All duct shall be galvanized steel unless noted otherwise. Fiberglass ductboard NOT permitted. 2.Provide flexible connection to vibration producing equipment. 3.Maximum 6 feet of flexible duct for connection to registers and diffusers only. Install properly supported with no kinks or sharp bends. Seal connections with adhesive and ties per Manufacturer's instructions. 5.Maximum of 8 feet total in runs of flexible duct for exhaust fans. 6.All mitered duct elbows are to be equipped with air-turning vanes. All radiused duct elbows are to have minimum interior radius equal to one times the duct width (width being duct dimension in direction of radius). 7.Provide duct transitions as required for clearance and duct crossovers. 8.All duct dimensions listed on plans are inside clear dimensions. 9.Install fire dampers in all ductwork greater than 100 square inches that penetrates a fire rated wall or barrier. D.Duct Sealing 1.Seal all duct joints according to one of the specified products. Method of application per manufacturer's instructions. The supply ducts shall have air losses of less than 10% of the total air flow volume measure at the fan or air-moving device. 3.2 COMMISSIONING, TESTING, AND BALANCING A.Equipment to be commissioned 1.Split System HVAC equipment 2.Fan/coil units 3.Exhaust fan 4.Controls B.Equipment checkout and startup 1.Verify proper installation, initial settings, and calibration of all controls and valves. 2.Provide startup as specified by manufacturer. 3.Verify sequence of operation as directed by the specifications and the manufacturer. 4.Verify all safety controls. C.Measurements and Adjustments 1.Measure all air flows, temperatures and other characteristics as indicated in the drawings and specifications or required by the manufacturer. 2.Measure motor currents. 3.Measure temperature rise or drop as appropriate through fan coils. 4.Adjust equipment for smooth, quiet operation. Lubricate as directed by the manufacturer 5.For outdoor condensing and heat pump units, measure and report: 5.1.Outdoor air temperature 5.2.Superheat 5.3.Subcooling 5.4.Final refrigerant charge D.Reports 1.Provide written test and balance report, including sequences tested. 2.Identify equipment, date and time of test. 3.Provide design, initial, and final airflow values. 4.Report shall be signed by Contractor and Owner's representative. E.Training 1.Provide a minimum 4 hours of on site training and instructions of the system operation. Schedule training with Owner in writing to allow for attendance by maintenance staff. Obtain Owner signoff for completion of training. 3.3 O&M, AS BUILTS AND WARRANTY A.Provide (1) hard copy and (1) digital copy of O&M manuals. B.Provide (1) full size hard copy and (1) digital copy of as-built drawings. C.Provide all warranty information. CODE SECTION COMPLIANCE C103.2.1 REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR DUCT AND PIPE INSULATION MATERIALS, ARCHITECTURAL DOCUMENTS FOR ALL OTHER INSULATION MATERIALS C103.2.2 REFERENCE ARCHITECTURAL PLANS FOR FENESTRATION U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTS C103.2.3 REFERENCE ARCHITECTURAL PLANSFOR AREA-WEIGHTED U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTS C103.2.4 MECHANICAL DESIGN CONFORMS TO 2020IECC AND IMC CODE REQUIREMENTS C103.2.5 REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIES C103.2.7 REFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT AND SYSTEM CONTROLS C103.2.8 REFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT HORSEPOWER AND CONTROLS C103.2.9 REFERENCE MECHANICAL AND PLUMBING SPECIFICATIONS FOR CEILING AND INSULATION LOCATIONS C103.2.12 REFERENCE MECHANICAL SPECIFICATIONS FOR AIR SEALING DETAILS C303.3 OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER BY CONTRACTOR FOR ALL EQUIPMENT C403.2.1 HVAC LOAD SIZING HAS BEEN PERFORMED IN THE CARRIER HAP PROGRAM, USING RTS (HEAT BALANCE) METHODOLOGY C403.2.3 ALL HVAC EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE MECHANICAL DOCUMENTS C403.2.4 REQUIRED HVAC CONTROLS SHALL BE PROVIDED, REFERENCE MECHANICAL DOCUMENTS C403.2.4.3 MOTORIZED DAMPERS PROVIDED FOR EXHAUST AND OUTSIDE AIR INTAKES GREATER THAN 300 CFM OR IN BUILDLINGS 3 STORIES OR LESS C403.2.9.1 DUCT IS REQUIRED TO BE INSULATED TO THE INDICATED MINIMUM LEVEL, REFERENCE MECHANICAL DOCUMENTS C403.2.9.3 INSTALLING CONTRACTOR SHALL ENSURE THAT ALL AIR DISTRIBUTION COMPONENTS ARE PROPERLY SEALED C403.2.9.5 DUCT SIZING AND DUCT DESIGN HAS BEEN PERFORMED, REFERENCE MECHANCIAL DOCUMENTS C403.2.10 ALL PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE MECHANICAL/PLUMBING DOCUMENTS C403.2.11 MECHANICAL SYSTEMS SHALL BE COMMISSIONED AS REQUIRED C403.5.3 ECONOMIZER CONTROL NOT REQUIRED. ALL INDIVIDUAL UNIT COOLING CAPACITIES ARE LESS THAN 270,000 BTU/HR C408.2.2 INSTALLING CONTRACTOR SHALL TEST AND BALANCE ALL HVAC SYSTEMS AND PROVIDE REPORT TO ENGINEER REQUIRED 2020 IECC ENERGY CONSERVATION COMPLIANCE ENERGY CONSERVATION CODE COMPLIANCE STATE TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT, THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE INTERNATIONAL ENERGY CODE, AS ADOPTED BY THE STATE. REVISIONS Δ DESCRIPTION DATE 4 REV. PERMIT 08/20/21 4 Bath Bedroom Closet Bedroom Kitchen Living/ Dining Mech Closet Mech Closet EF-1 F E E FC-1 8"ø 8"ø 4"ø 4"ø 6"ø 4"ø 16"x10" A B 6"ø8"ø CONNECT TO HOOD PROVIDED BY G.C. CONNECT TO RETURN DUCT PROVIDE DRYERBOX DB-480, CONNECT 4" DUCT 270 CFM 270 CFM 100 CFM Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/2" = 1'-0"8/20/2021 12:54:29 PMM2.00 Mechanical Unit Plan 1.0 STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/2" = 1'-0"1 Mechanical Enlarged Unit Plan 1.0 1.ALL DUCT PENETRATIONS AT CEILING REQUIRE CEILING RADIATION DAMPERS (1.5 HR). REFER TO M3.00 FOR ADDITIONAL DETAILS. MECHANICAL UNIT PLAN GENERAL NOTES REVISIONS Δ DESCRIPTION DATE Living/ Dining Bath Bedroom Bedroom Mech Closet Kitchen Chase 2 2 M3.00 __________ B 0 CFM A EF-16"ø 4"ø 6"ø 20"x13" FC-1 6"ø E E F F 8"ø 8"ø 6"ø CONNECT TO HOOD PROVIDED BY G.C. CONNECT TO RETURN DUCT PROVIDE DRYERBOX DB-480, CONNECT 4" DUCT 220 CFM 220 CFM 100 CFM 100 CFM 4"ø Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/2" = 1'-0"8/20/2021 12:55:17 PMM2.01 Mechanical Unit Plan 2.0 STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/2" = 1'-0"1 Mechanical Enlarged Unit Plan 2.0 1.ALL DUCT PENETRATIONS AT CEILING REQUIRE CEILING RADIATION DAMPERS (1.5 HR). REFER TO M3.00 FOR ADDITIONAL DETAILS. MECHANICAL UNIT PLAN GENERAL NOTES REVISIONS Δ DESCRIPTION DATE Mech Closet Living/ Dining Coat Closet Mech Closet Bath Bedroom Bedroom Kitchen E F F A B 6"ø 6"ø 8"ø 6"ø 8"ø 12"x10" 8"ø 4"ø EF-1 6"ø 4"ø FC-1 E CONNECT TO HOOD PROVIDED BY G.C.CONNECT TO RETURN DUCT PROVIDE DRYERBOX DB-480, CONNECT 4" DUCT 100 CFM 100 CFM 220 CFM 220 CFM Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/2" = 1'-0"8/20/2021 12:56:59 PMM2.02 Mechanical Unit Plan 2.1 STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/2" = 1'-0"1 Mechanical Enlarged Unit Plan 2.1 1.ALL DUCT PENETRATIONS AT CEILING REQUIRE CEILING RADIATION DAMPERS (1.5 HR). REFER TO M3.00 FOR ADDITIONAL DETAILS. MECHANICAL UNIT PLAN GENERAL NOTES REVISIONS Δ DESCRIPTION DATE Living/ Dining Coat Closet Bedroom Bedroom BathKitchen Hall Mech Closet Bedroom Closet Bedroom Closet E E F F EF-1 4"ø 6"ø 4"ø 6"ø 8"ø 8"ø 12"x10" 6"ø 6"ø AB FC-1 CONNECT TO HOOD PROVIDED BY G.C. CONNECT TO RETURN DUCT PROVIDE DRYERBOX DB-480, CONNECT 4" DUCT 220 CFM 100 CFM 100 CFM 220 CFM Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/2" = 1'-0"8/20/2021 12:58:18 PMM2.03 Mechanical Unit Plan 2.2 STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/2" = 1'-0"1 Mechanical Enlarged Unit Plan 2.2 1.ALL DUCT PENETRATIONS AT CEILING REQUIRE CEILING RADIATION DAMPERS (1.5 HR). REFER TO M3.00 FOR ADDITIONAL DETAILS. MECHANICAL UNIT PLAN GENERAL NOTES REVISIONS Δ DESCRIPTION DATE FC-1 E 220 CFM E 220 CFM F 100 CFM F 100 CFM 8"ø 16"x10" 8"ø 6"ø 6"ø 6"ø EF-1 4"ø 4"ø 6"ø Living/ Dining Bedroom Bedroom Hall Bath CONNECT TO HOOD PROVIDED BY G.C. A CONNECT TO RETURN DUCT PROVIDE DRYERBOX DB-480, CONNECT 4" DUCT B Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/2" = 1'-0"8/20/2021 11:09:17 AMMA2.04 Enlarged Unit Plan 2.3 -Mechanical STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/2" = 1'-0"1 Type 2.3 Mechanical 1. ALL DUCT PENETRATIONS AT CEILING REQUIRE CEILING RADIATION DAMPERS (1.5 HR). REFER TO M3.00 FOR ADDITIONAL DETAILS. MECHANICAL UNIT PLAN GENERAL NOTES REVISIONS Δ DESCRIPTION DATE Dining Bedroom Coat Closet Bedroom Bedroom Bath Mech Closet Kitchen 6"ø B 16"x12" FC-1 EF-1 F F F E F 6"ø 6"ø 6"ø 6"ø 8"ø 6"ø CONNECT TO HOOD PROVIDED BY G.C. CONNECT TO RETURN DUCT PROVIDE DRYERBOX DB-480, CONNECT 4" DUCT 100 CFM 100 CFM 100 CFM 240 CFM 100 CFM A 4"ø 4 Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/2" = 1'-0"8/20/2021 1:00:08 PMM2.05 Mechanical Unit Plan 3.0 STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/2" = 1'-0"1 Mechanical Enlarged Unit Plan 3.0 1.ALL DUCT PENETRATIONS AT CEILING REQUIRE CEILING RADIATION DAMPERS (1.5 HR). REFER TO M3.00 FOR ADDITIONAL DETAILS. MECHANICAL UNIT PLAN GENERAL NOTES REVISIONS Δ DESCRIPTION DATE 4 REV. PERMIT 08/20/21 Kitchen Bedroom Coat Closet Bedroom Bedroom Bath Kitchen B 6"ø 6"ø 16"x12" FC-1 4"ø EF-1 4"ø FFF E F 6"ø6"ø 6"ø 6"ø 8"ø A CONNECT TO HOOD PROVIDED BY G.C. CONNECT TO RETURN DUCT PROVIDE DRYERBOX DB-480, CONNECT 4" DUCT 100 CFM 100 CFM 100 CFM 100 CFM 140 CFM 4 Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/2" = 1'-0"8/20/2021 1:00:36 PMM2.06 Mechanical Unit Plan 3.1 STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/2" = 1'-0"1 Mechanical Enlarged Unit Plan 3.1 1.ALL DUCT PENETRATIONS AT CEILING REQUIRE CEILING RADIATION DAMPERS (1.5 HR). REFER TO M3.00 FOR ADDITIONAL DETAILS. MECHANICAL UNIT PLAN GENERAL NOTES REVISIONS Δ DESCRIPTION DATE 4 REV. PERMIT 08/20/21 PROVIDE STEEL SLEVES AT OUTDOOR AIR DUCT PENETRATIONS AT CORRIDOR WALL, SLEEVE SHALL BE: A MINIMUM 12-INCH-LONG (305 MM) BY 0.060-INCH-THICK (1.52 MM) STEEL SLEEVE SHALL BE CENTERED IN EACH DUCT OPENING. THE SLEEVE SHALL BE SECURED TO BOTH SIDES OF THE WALL AND ALL FOUR SIDES OF THE SLEEVE WITH MINIMUM 11/2-INCH BY 11/2-INCH BY 0.060-INCH (38 MM BY 38 MM BY 1.52 MM) STEEL RETAINING ANGLES. THE RETAINING ANGLES SHALL BE SECURED TO THE SLEEVE AND THE WALL WITH NO. 10 (M5) SCREWS. THE ANNULAR SPACE BETWEEN THE STEEL SLEEVE AND THE WALL OPENING SHALL BE FILLED WITH MINERAL WOOL BATTING ON ALL SIDES DUCT CEILING RADIATION DAMPER GREENHECK CRD-1CEILING RADIATION DAMPER GREENHECK CRD-1 FC-1 PROVIDE CUSTOM STEEL ANGLE FRAME, RETURN PLENUM WITH FILTER ASSEMBLY TO FIT A 1" FILTER 10"X10" ACCESS LOW LEAKAGE HATCH PROVIDE 3/4" PVC CONDENSATE PIPE FROM FAN COIL TO CONDENSATE ACCEPTOR WITH 1" AIR GAP, ALL CONDENSATE RISERS AND ACCEPTORS ARE PROVIDED BY PLUMBING CONTRACTOR ERV-1 EDH-1 8"ø 8"ø CEILING RADIATION DAMPER AT ALL PENETRATIONS PROVIDE WALL MOUNT HARDWARE AND FASTENERS FC-1 6"ø CEILING RADIATION DAMPER DUCT ACCESS HATCH PROVIDE R-6 INSULATION CONNECT TO MICROWAVE EXHAUST HOOD PROVIDE 10"X10" ACCESS PANEL 6"ø DUCT ACCESS HATCH CEILING RADIATION DAMPER Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/4" = 1'-0"8/20/2021 1:01:35 PMM3.00 Mechanical Details STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/4" = 1'-0"1 Typical Corridor Wall Penetration 1/4" = 1'-0"2 Typical Ceiling Radiation Damper Detail 1/4" = 1'-0"3 Typical Wall Mounted ERV Layout 1/4" = 1'-0"4 Typical Outdoor Air Duct 1/4" = 1'-0"5 Typical Kitchen Exhaust Duct REVISIONS Δ DESCRIPTION DATE Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 8/20/2021 1:03:40 PMM4.00 MECHANICAL SCHEDULES STRM01OVERLOOK 06/01/21 CONSTRUCTION SETCONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 14850ELECTRIC WALL HEATER SCHEDULE Type Mark Manufacturer Model Description Watts Voltage Phase Comments EWH-1 Qmark SSHO4008 Electric Wall Heater 4000 208 V 1 ELECTRIC BASEBOARD HEATER SCHEDULE Type Mark Manufacturer Model Description Watts Voltage Phase Comments EBH-1 Qmark 2508W Electric Baseboard Heater 2000 208 V 1 Provide unit mounted thermostat AIR TERMINAL SCHEDULE Type Manufacturer Model Description Material & Color Border Type NECK SIZE CommentsWidth Height A XVENTBOX THEB-446-R-S Triple exhaust Plastic Surface Mount 16" 12" Color TBD by architect, remove damper, 8 week lead time, coordinate exact model number with wall type B XVENTBOX Plastic Surface Mount 8 3/4" Color TBD by architect, remove damper, 8 week lead time, coordinate exact model number with wall type D XVENTBOX 8SEB-S Single outdoor air intake and exhaust Plastic Surface Mount 8 3/4" 8" Color TBD by architect, remove damper, 8 week lead time, coordinate exact model number with wall type E Hart & Cooley 631 Adjustable Supply Grille with Double Deflection Steel - Titus - 26 White Surface Mount 14" 8" Provide ceiling radiation dampers F Hart & Cooley 631 Adjustable Supply Grille with Double Deflection Steel - Titus - 26 White Surface Mount 12" 6" Provide ceiling radiation dampers G Titus 350RL Return Grille with 35 Degree Deflection Steel - Titus - 26 White Surface Mount 14" 6" Provide ceiling radiation dampers H Titus 300RL Adjustable Supply Grille with Double Deflection Steel - Titus - 26 White Surface Mount 14" 6" Provide ceiling radiation dampers I Titus 350RL Return Grille with 35 Degree Deflection Steel - Titus - 26 White Surface Mount 8" 6" Provide ceiling radiation dampers J Titus 300RL Adjustable Supply Grille with Double Deflection Steel - Titus - 26 White Surface Mount 6" 6" K Titus 350RL Return Grille with 35 Degree Deflection Steel - White Surface Mount 6" 6" FAN SCHEDULE Type Manufacturer Model Description Air Flow CFM Exhaust External Static Pressure Sones Weight, lbs ELECTRICAL CommentsVoltage Phase MCA EF-1 Broan ZB-80 Ceiling exhaust fan 65 CFM 0.60 .3 15 lb 120 V 1 0.3 A FAN COIL SCHEDULE Type Manufacturer Model Description Air Flow cfm Cooling Btu/Hr Heating Length Width Height Weight, lbs ELECTRICAL CommentsTotal Btu/Hr Voltage Phase MCA FC-1 LG Electronics LVN181HV4 Vertical Ducted Fan Coil with duct heater 640 CFM 24000 Btu/h 24000 Btu/h 1' - 9 1/4" 1' - 6" 4' - 1" 116 lb 208 V 1 20.0 A Provide Aspen mini aqua condensate pump, PREMTBVCO thermostat, PVC condensate piping, ANEH033B1 duct heater, MERV 13 filter section FC-2 LG Electronics ARNU093SJA4 Wall Mounted Fan Coil 275 CFM 9600 Btu/h 10900 Btu/h 2' - 8" 6" 1' - 0 1/2" 19 lb 208 V 1 0.2 A Provide Aspen mini aqua condensate pump, PREMTBVCO thermostat, PVC condensate piping FC-3 LG Electronics ARNU153SJA4 Wall Mounted Fan Coil 371 CFM 15400 Btu/h 17100 Btu/h 2' - 8" 6" 1' - 0 1/2" 19 lb 208 V 1 0.2 A Provide Aspen mini aqua condensate pump, PREMTBVCO thermostat, PVC condensate piping FC-4 LG Electronics LAN180HYV3 Wall Mounted Fan Coil 813 CFM 9600 Btu/h 10900 Btu/h 2' - 8" 6" 1' - 0 1/2" 37 lb 208 V 1 0.2 A Provide Aspen mini aqua condensate pump, PREMTBVCO thermostat, PVC condensate piping FC-5 LG Electronics LSN120HSV5 Wall Mounted Fan Coil 459 CFM 13785 Btu/h 22178 Btu/h 2' - 8" 6" 1' - 0 1/2" 19 lb 208 V 1 0.2 A Provide Aspen mini aqua condensate pump, PREMTBVCO thermostat, PVC condensate piping HEAT PUMP SCHEDULE Type Manufacturer Model Description Cooling EER Heating COP Heating Seasonal Performance Factor Length Width Heigh t Weight, lbs ELECTRICAL CommentsTotal Btu/Hr Capacity Btu/Hr Voltage Phase MCA HP-1 LG Electronics LUU189HV Heat Pump 24000 Btu/h 13.3 24000 Btu/h 3.66 10.4 37" 15" 33" 130 lb 208 V 1 20.0 A Provide wind baffles, base pan heater, 24" tall Quicksling stand, furnish disconnect HP-2 LG Electronics ARNU048GSS4 Heat Pump 48000 Btu/h 10.5 48000 Btu/h 3.2 9.5 37" 13" 54" 207 lb 208 V 1 30.0 A Provide wind baffles, base pan heater, 24" tall Quicksling stand, furnish disconnect HP-3 LG Electronics ARNU024GSS4 Heat Pump 24000 Btu/h 10.7 24000 Btu/h 4.06 10 37" 13" 33" 159 lb 208 V 1 19.6 A Provide wind baffles, base pan heater, 24" tall Quicksling stand, furnish disconnect HP-4 LG Electronics LAU180HYV3 Heat Pump 29515 Btu/h 14.4 32000 Btu/h 4 10 37" 15" 33" 130 lb 208 V 1 19.0 A Provide wind baffles, base pan heater, 24" tall Quicksling stand, furnish disconnect HP-5 LG Electronics LSU120HSV5 Heat Pump 13785 Btu/h 12.5 22178 Btu/h 4.06 11.4 37" 13" 33" 159 lb 208 V 1 10.0 A Provide wind baffles, base pan heater, 24" tall Quicksling stand, furnish disconnect ENERGY RECOVERY VENTILATOR SCHEDULE Type Manufacturer Model Description Air Flow CFM Supply ESP, in. WC Weight, lbs ELECTRICAL CommentsVoltage Phase MCA ERV-1 RenewAire EV450IN Energy Recovery Ventilator 200 CFM 0.75 in-wg 200 lb 208 V 1 5 A Provide speed controller, CO2 sensor, occupancy sensor, timeclock, motorized dampers ERV-2 RenewAire EV Premium L Energy Recovery Ventilator 100 CFM 0.40 in-wg 52 lb 120 V 1 10 A Provide speed controller, CO2 sensor, occupancy sensor, motorized dampers ELECTRIC DUCT HEATER SCHEDULE Type Mark Manufacturer Model Description Watts Voltage Phase Comments EDH-1 RenewAire RH-D Electric Duct Heater 2000 208 V 1 REVISIONS Δ DESCRIPTION DATE 4 REV. PERMIT 08/20/21 FIRE & SMOKE DAMPER SCHEDULE Type Mark Manufacturer Model Description Voltage Phase Comments FSD-1 Ruskin FSDR60 Fire and smoke damper with actuator 24 V 1 Provide test switch, 24 volt power to actuatorassembly with bracket, switch package, duct smoke detector, TS150 firestat, fusible link, access panel, duct access hatch. Horizontal installations shall have retaining plates on both sides, vertical installations shall have retaining plates on one side 4 Rotated Unit Type 3.0 Typical Unit Type 2.1 433 SF Study Room Pump Room Maintenance Elev 0 Stair 0W Corridor 0 See 1/ MA2.02See 1/ MA2.05 EWH-1 EWH-1 B 100 CFM FC-4 B 100 CFM J 50 CFM K 50 CFM 6"ø6"ø ERV-2 6"ø 6"ø 6"ø 6"ø J 100 CFM K 100 CFM EDH-1 EF-2 K 50 CFM K 50 CFM K 50 CFM 6"ø 6"øEWH-1 EWH-1 PROVIDE 3/4" RIGID PVC CONDENSATE PIPING UP IN JOIST SPACE TO STUDY ROOM DRAIN PROVIDE CEILING RADIATION DAMPER PROVIDE CEILING RADIATION DAMPER PROVIDE CEILING ACCESS PANEL4 4 B4 3 MA1.00 __________ PROVIDE 26 GAGE SUPPLY & RETURN DUCT CONTINUOUS FROM AIR TERMINAL TO ERV-1 4 PROVIDE FDR25 6" ROUND FIRE DAMPER AND DUCT ACCESS HATCH 4 Rotated Unit Type 3.0 Typical Unit Type 2.1 Typical Unit Type 2.0 Typical Unit Type 3.1 Elev 1 Corridor 1 Stair 1W Storage See 1/ MA2.01See 1/ MA2.02See 1/ MA2.05 See 1/ MA2.06 EBH-1 EBH-1 ERV-1 DD 200 CFM 200 CFM 8"ø 8"ø 8"ø8"ø EDH-1 6"ø6"ø 6"ø 6"ø K 50 CFM J 50 CFM FSD-1 FSD-1 DUCT IN CHASE DOWN TO GROUND FLOOR CEILING B EF-1 4"ø 4 3 MA1.00 __________ First Floor T.O. Slab 0" Second Floor T.O. Slab 9' -6" Ground Floor T.O. Slab -9' -6" Ground Floor T.O. Wall -1' -3" First Floor T.O. Wall 8' -3" Building A -First Floor 714' -6" Building B -First Floor 724' -0" Building A -Ground Floor T.O. Slab 705' -0" 26 GAGE DUCT 1HOUR FIRE PARTITION Storage Corridor 0 Corridor 1 Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com As indicated8/20/2021 10:57:07 AMMA1.00 Building "A" Ground & First Floor Plan STRM01OVERLOOK 06/01/21 CONSTRUCTION SET BUILDING A CONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/8" = 1'-0"1 Building "A" Ground Floor Plan 1/8" = 1'-0"2 Building "A" First Floor Plan 1.EXHAUST SHALL BE 3' FROM ALL WINDOW OPENINGS. INTAKE SHALL BE 10' FROM ALL EXHAUST LOCATIONS. COORDINATE WITH ALL PENETRATIONS WITH G.C. 2.ALL OUTDOOR AIR INTAKE AND MAKE- UP AIR DUCTS ARE TO BE INSULATED WITH CONTINUOUS R-6 DUCT INSULATION. 3.REFER TO M3.00 FOR TYPICAL PENETRATION OF CORRIDOR PARTITION WALL. 4.THERMOSTATS SHALL BE MOUNTED AT 60" AFF. GENERAL NOTES REVISIONS Δ DESCRIPTION DATE 4 REV. PERMIT 08/20/21 1/4" = 1'-0"3 CORRIDOR WALL DUCT PENETRATION 4 Rotated Unit Type 3.0 Typical Unit Type 2.1 Typical Unit Type 2.0 Typical Unit Type 3.1 Mirrored Unit Type 2.1M Mirrored Unit Type 2.0MRotated Unit Type 2.1 Elev 2 Stair 2W Stair 2E Corridor 2 See 1/ MA2.01 See 1/ MA2.01 See 1/ MA2.02 See 1/ MA2.02See 1/ MA2.02 See 1/ MA2.05 See 1/ MA2.06 J 50 CFM K 50 CFM 6"ø 6"ø EWH-1 FSD-1 FSD-1 3 MA1.00 __________ Rotated Unit Type 3.0 Typical Unit Type 2.1 Typical Unit Type 2.0 Typical Unit Type 3.1 Mirrored Unit Type 2.1M Mirrored Unit Type 2.0MTypical Unit Type 3.0 Corridor 3 Stair 3W Elev 3 Stair 3E CC See 1/ MA2.01 See 1/ MA2.01 See 1/ MA2.02 See 1/ MA2.02 See 1/ MA2.05 See 1/ MA2.05See 1/ MA2.06 EWH-1 EWH-1 K 50 CFM 6"ø 6"ø J 50 CFM FSD-1 FSD-1 Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/8" = 1'-0"8/20/2021 11:00:25 AMMA1.01 Building "A" Second & Third Floor Plan STRM01OVERLOOK 06/01/21 CONSTRUCTION SET BUILDING A CONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/8" = 1'-0"1 Building "A" Second Floor Plan 1/8" = 1'-0"2 Building "A" Third Floor Plan 1.EXHAUST SHALL BE 3' FROM ALL WINDOW OPENINGS. INTAKE SHALL BE 10' FROM ALL EXHAUST LOCATIONS. COORDINATE WITH ALL PENETRATIONS WITH G.C. 2.ALL OUTDOOR AIR INTAKE AND MAKE- UP AIR DUCTS ARE TO BE INSULATED WITH CONTINUOUS R-6 DUCT INSULATION. 3.REFER TO M3.00 FOR TYPICAL PENETRATION OF CORRIDOR PARTITION WALL. 4.THERMOSTATS SHALL BE MOUNTED AT 60" AFF. GENERAL NOTES REVISIONS Δ DESCRIPTION DATE Rotated Unit Type 3.0 Typical Unit Type 2.1 Typical Unit Type 2.0 Typical Unit Type 2.3 Mirrored Unit Type 2.1M Mirrored Unit Type 2.0MTypical Unit Type 3.0 Elev 4 Stair 4W Corridor 4 Stair 4E See 1/ MA2.01 See 1/ MA2.01 See 1/ MA2.02 See 1/ MA2.02 See 1/ MA2.05 See 1/ MA2.05See 1/ E3.04 6"øK 50 CFM 6"ø J 50 CFM PRO1 T855SH THERMOSTAT WITH R251S WIRED REMOTE SENSOR. CONNECT TO THE LG WALL MOUNTED INDOOR UNIT LOCATED AT THE TOP OF THE ELEVATOR SHAFT VIA A LG PDRYCB300 DRY CONTACT. THE REMOTE SENSOR SHALL BE LOCATED IN THE HOISTWAY EWH-1 EWH-1 FSD-1 FSD-1 IN FLOOR IN FLOOR HP-1HP-1HP-1HP-1HP-1HP-1 HP-1 HP-1HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 HP-1HP-1HP-1HP-1HP-1 HP-1 HP-1 HP-1 HP-1HP-4 1ST FLOOR LOUNGE PROVIDE CUSTOM INSULATED PIPE CURB WITH SIDE MOUNTED EXIT SEALS/CAPS FOR EACH PENETRATION, ALL ROOF PENETRATIONS SHALL BE FULLY SEALED, TYPICAL PROVIDE 16"X6" CONCRETE PAVER FOR EACH STAND LEG, SECURE LEG TO PAVER, TYPICAL FC-5 HP-5 ELEVATOR FAN COIL SHALL HAVE MINIMUM 12" CLEARANCE AT TOP OF UNIT. PROVIDE 1" CPVC CONDENSATE PIPING FROM UNIT DOWN TO GROUND FLOOR SUMP. TERMINATE WITH BUG SCREEN AND AIR GAP. Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/8" = 1'-0"8/20/2021 11:02:45 AMMA1.02 Building "A" Fourth Floor & Roof Plan STRM01OVERLOOK 06/01/21 CONSTRUCTION SET BUILDING A CONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/8" = 1'-0"1 Building "A" Fourth Floor Plan 1/8" = 1'-0"2 Building "A" Roof Plan 1.EXHAUST SHALL BE 3' FROM ALL WINDOW OPENINGS. INTAKE SHALL BE 10' FROM ALL EXHAUST LOCATIONS. COORDINATE WITH ALL PENETRATIONS WITH G.C. 2.ALL OUTDOOR AIR INTAKE AND MAKE- UP AIR DUCTS ARE TO BE INSULATED WITH CONTINUOUS R-6 DUCT INSULATION. 3.REFER TO M3.00 FOR TYPICAL PENETRATION OF CORRIDOR PARTITION WALL. 4.THERMOSTATS SHALL BE MOUNTED AT 60" AFF. GENERAL NOTES REVISIONS Δ DESCRIPTION DATE 201 Elev 2 Typical Unit Type 3.1 Typical Unit Type 2.1 Rotated Unit Type 2.1 Typical Unit Type 3.0 Typical Unit Type 2.0 Mirrored Unit Type 2.1M Mirrored Unit Type 2.0M Typical Unit Type 2.2Mirrored Unit Type 2.2 Elev 2 Stair 2W Corridor 2 Stair 2E See 1/ M2.03 See 1/ M2.03 See 1/ M2.06 See 1/ M2.02 See 1/ M2.02See 1/ M2.05 See 1/ M2.01 See 1/ M2.01See 1/ M2.02 EWH-1 6"øK 50 CFM J 50 CFM FSD-1 FSD-1 6"ø Typical Unit Type 3.1 Typical Unit Type 2.1 Typical Unit Type 1.0 Mirrored Unit Type 2.1M Typical Unit Type 2.0 Mirrored Unit Type 2.1M Mirrored Unit Type 2.0M Mirrored Unit Type 2.1Typical Unit Type 2.1 Elev 3 Stair 3W Stair 3E Corridor 3 EWH-1 EWH-1 See 1/ M2.02 See 1/ M2.02 See 1/ M2.02 See 1/ M2.02See 1/ M2.02 See 1/ M2.01 See 1/ M2.01See 1/ M2.00See 1/ M2.06 EWH-1 K 50 CFM 6"ø J 50 CFM FSD-1 FSD-1 6"ø B DUCT IN BAR JOIST SPACE 4"ø EF-1 4 Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/8" = 1'-0"8/20/2021 1:07:37 PMMB1.01 Building "B" Second & Third Floor Plans STRM01OVERLOOK 06/01/21 CONSTRUCTION SET BUILDING B CONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/8" = 1'-0"1 Building "B" Second Floor Plan 1/8" = 1'-0"2 Building "B" Third Floor Plan 1.EXHAUST SHALL BE 3' FROM ALL WINDOW OPENINGS. INTAKE SHALL BE 10' FROM ALL EXHAUST LOCATIONS. COORDINATE WITH ALL PENETRATIONS WITH G.C. 2.ALL OUTDOOR AIR INTAKE AND MAKE- UP AIR DUCTS ARE TO BE INSULATED WITH CONTINUOUS R-6 DUCT INSULATION. 3.REFER TO M3.00 FOR TYPICAL PENETRATION OF CORRIDOR PARTITION WALL. 4.THERMOSTATS SHALL BE MOUNTED AT 60" AFF. GENERAL NOTES REVISIONS Δ DESCRIPTION DATE 4 REV. PERMIT 08/20/21 Maintenance Elev 0 Stair 0W Corridor 0 EBH-1 EWH-1 Typical Unit Type 3.1 Typical Unit Type 2.1 Rotated Unit Type 2.1 Typical Unit Type 3.0 Typical Unit Type 2.0 Game Room Gym Storage Corr. 1.1 Stair 1E Corridor 1.0 See 1/ M2.06 See 1/ M2.01See 1/ M2.02 See 1/ M2.02 See 1/ M2.05 FC-2 FC-2 FC-3 FC-3 EWH-1 EWH-1 ERV-1 3 M3.00 __________ EDH-1 ERV-1EDH-1 H G200 CFM 200 CFM D 200 CFM D 200 CFM D D 225 CFM 225 CFM G 175 CFM H 225 CFM I 50 CFM 8"ø 8"ø 8"ø 8"ø 8"ø 8"ø6"ø ERV-1J 50 CFM 8"ø8"ø 8"ø K EWH-1 EWH-1 EDH-1 8"ø 6"ø 6"ø 8"ø 8"ø D D FSD-1 FSD-1Gym Restroom PROVIDE CEILING RADIATION DAMPERS FOR EVERY CEILING PENETRATION, TYPICAL PROVIDE CEILING RADIATION DAMPERS FOR EVERY CEILING PENETRATION, TYPICAL Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/8" = 1'-0"8/20/2021 1:04:46 PMMB1.00 Building "B" Ground & First Floor Plans STRM01OVERLOOK 06/01/21 CONSTRUCTION SET BUILDING B CONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/8" = 1'-0"1 Building "B" Ground Floor Plan 1/8" = 1'-0"2 Building "B" First Floor Plan 1.EXHAUST SHALL BE 3' FROM ALL WINDOW OPENINGS. INTAKE SHALL BE 10' FROM ALL EXHAUST LOCATIONS. COORDINATE WITH ALL PENETRATIONS WITH G.C. 2.ALL OUTDOOR AIR INTAKE AND MAKE- UP AIR DUCTS ARE TO BE INSULATED WITH CONTINUOUS R-6 DUCT INSULATION. 3.REFER TO M3.00 FOR TYPICAL PENETRATION OF CORRIDOR PARTITION WALL. 4.THERMOSTATS SHALL BE MOUNTED AT 60" AFF. GENERAL NOTES REVISIONS Δ DESCRIPTION DATE Typical Unit Type 3.1 Typical Unit Type 2.1 Rotated Unit Type 2.1 Typical Unit Type 3.0 Typical Unit Type 2.0 Mirrored Unit Type 2.1M Mirrored Unit Type 2.0M Mirrored Unit Type 2.1 Elev 4 Stair 4W Stair 4E Roof Terrace Fourth Floor Lounge Corridor 4 FC-2 FC-2 See 1/ M2.02 See 1/ M2.02 See 1/ M2.02See 1/ M2.02 See 1/ M2.01 See 1/ M2.01See 1/ M2.05See 1/ M2.06 ERV-1 EDH-1 D 200 CFM D 200 CFM 8"ø 8"ø 8"øG 200 CFM 8"ø H 200 CFM PRO1 T855SH THERMOSTAT WITH R251S WIRED REMOTE SENSOR. CONNECT TO THE LG WALL MOUNTED INDOOR UNIT LOCATED IN THE ELEVATOR SHAFT VIA A LG PDRYCB300 DRY CONTACT. THE REMOTE SENSOR SHALL BE LOCATED IN THE HOISTWAY EWH-1 EWH-1 6"ø 6"ø K 50 CFM J 50 CFM FSD-1 FSD-1 IN FLOOR IN FLOOR PROVIDE CEILING RADIATION DAMPERS FOR EVERY CEILING PENETRATION, TYPICAL HP-2 GYM HP-1 UNIT 1B HP-1 UNIT 1C HP-1 UNIT 1D HP-1 UNIT 1E HP-1 UNIT 2A HP-1 UNIT 2B HP-1 UNIT 2C HP-1 UNIT 2D HP-1 UNIT 2E HP-1 UNIT 2F HP-1 UNIT 2G HP-1 UNIT 2H HP-1 UNIT 2J HP-1 UNIT 3A HP-1 UNIT 4H HP-1 UNIT 4G HP-1 UNIT 4F HP-1 UNIT 4E HP-1 UNIT 4D HP-1 UNIT 4C HP-1 UNIT 4B HP-1 UNIT 4A HP-1 UNIT 3J HP-1 UNIT 3H HP-1 UNIT 3G HP-1 HP-1 UNIT 3E HP-1 UNIT 3D HP-1 UNIT 3C HP-1 UNIT 3F HP-3 1ST GAME RM HP-3 4TH FL LOUNGE HP-1 UNIT 1A PROVIDE CUSTOM INSULATED PIPE CURB WITH SIDE MOUNTED EXIT SEALS/CAPS FOR EACH PENETRATION, ALL ROOF PENETRATIONS SHALL BE FULLY SEALED, TYPICAL PROVIDE 16"X6" CONCRETE PAVER FOR EACH STAND LEG, SECURE LEG TO PAVER, TYPICAL FC-5 ELEVATOR HP-5 ELEVATOR FAN COIL SHALL HAVE MINIMUM 12" CLEARANCE AT TOP OF UNIT. PROVIDE 1" CPVC CONDENSATE PIPING FROM UNIT DOWN TO GROUND FLOOR SUMP. TERMINATE WITH BUG SCREEN AND AIR GAP. Project # Date 108 W. State St. Fl 2 Ithaca, New York 14850 ph: 607.216.8802 www.streamcolab.com COPYRIGHT STREAM COLLABORATIVE/ TAITEM. ALL RIGHTS RESERVEDA 1 2 3 4 BCD 110 South Albany St. Ithaca, New York 14850 ph: 607.277.1118 www.taitem.com 1/8" = 1'-0"8/20/2021 1:08:51 PMMB1.02 Building "B" Fourth Floor & Roof Plans STRM01OVERLOOK 06/01/21 CONSTRUCTION SET BUILDING B CONSTRUCTION SETVisum Development Group815 South Aurora StreetIthaca, New York 148501/8" = 1'-0"1 Building "B" Fourth Floor Plan 1/8" = 1'-0"2 Building "B" Roof Floor Plan 1.EXHAUST SHALL BE 3' FROM ALL WINDOW OPENINGS. INTAKE SHALL BE 10' FROM ALL EXHAUST LOCATIONS. COORDINATE WITH ALL PENETRATIONS WITH G.C. 2.ALL OUTDOOR AIR INTAKE AND MAKE- UP AIR DUCTS ARE TO BE INSULATED WITH CONTINUOUS R-6 DUCT INSULATION. 3.REFER TO M3.00 FOR TYPICAL PENETRATION OF CORRIDOR PARTITION WALL. 4.THERMOSTATS SHALL BE MOUNTED AT 60" AFF. GENERAL NOTES REVISIONS Δ DESCRIPTION DATE