HomeMy WebLinkAbout2018025- 238 Dryden Rd- ComCheck compliance-report-20210615 (2)COMcheck Software Version 4.1.5.1 Envelope Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Permit No.38763 Vertical Glazing / Wall Area:6% Location:Ithaca, New York Climate Zone:6a Construction Site: 238 Dryden Rd Ithaca, NY 14850 Owner/Agent: Todd Fox Visum Development 119 S. Cayuga St 3rd floor Ithaca, NY 14850 607-269-7300 todd@visumdevelopment.com Designer/Contractor: Noah Demarest STREAM Collaborative 108 W. State St 2nd floor Ithaca, NY 14850 607-216-8802 noah@streamcolab.com Project Information Energy Code: 238 Dryden Rd Enhanced Interior Lighting Controls Additional Efficiency Package(s) Building Area Floor Area 1-Multifamily : Residential 9657 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter basement slab: Slab-On-Grade:Heated Fully Insulated (user specified perimeter R-value + R-10.0 under slab), [Bldg. Use 1 - Multifamily] (d) 180 ---12.5 0.530 0.602 NORTH basement north icf: Solid Concrete:8" Thickness, Normal Density, Furring: None, [Bldg. Use 1 - Multifamily] 401 ---22.0 0.042 0.071 wood framed north wall: Wood-Framed, 16" o.c., [Bldg. Use 1 - Multifamily] 1613 30.0 0.0 0.053 0.051 Window 1 copy 1: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID INTERTEK LPB/WPPS-60-01, SHGC 0.28, VT 0.48, [Bldg. Use 1 - Multifamily] (c) 106 ------0.270 0.430 Door 4: Other Door, Swinging, [Bldg. Use 1 - Multifamily]93 ------0.230 0.370 EAST basement east icf: Solid Concrete:8" Thickness, Normal Density, Furring: None, [Bldg. Use 1 - Multifamily] 554 ---22.0 0.042 0.071 Door 3: Other Door, Swinging, [Bldg. Use 1 - Multifamily]15 ------0.230 0.370 wood framed east wall: Wood-Framed, 16" o.c., [Bldg. Use 1 - Multifamily] 2465 30.0 0.0 0.053 0.051 Window 1 copy 2: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID INTERTEK LPB/WPPS-60-01, SHGC 0.28, VT 0.48, [Bldg. Use 1 - Multifamily] (c) 159 ------0.270 0.430 Door 4 copy 1: Other Door, Swinging, [Bldg. Use 1 - Multifamily]8 ------0.230 0.370 Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 201 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter SOUTH basement south wood framed: Wood-Framed, 16" o.c., [Bldg. Use 1 - Multifamily] 130 30.0 0.0 0.053 0.051 Window 2: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID INTERTEK LPB/WPPS-60-01, SHGC 0.28, VT 0.48, [Bldg. Use 1 - Multifamily] (c) 25 ------0.270 0.430 Door 1: Other Door, Swinging, [Bldg. Use 1 - Multifamily]21 ------0.230 0.370 Door 2: Other Door, Swinging, [Bldg. Use 1 - Multifamily]21 ------0.230 0.370 basement southwest wood framed: Wood-Framed, 16" o.c., [Bldg. Use 1 - Multifamily] 96 30.0 0.0 0.053 0.051 Window 1: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID INTERTEK LPB/WPPS-60-01, SHGC 0.28, VT 0.48, [Bldg. Use 1 - Multifamily] (c) 50 ------0.270 0.430 wood framed south wall: Wood-Framed, 16" o.c., [Bldg. Use 1 - Multifamily] 1662 30.0 0.0 0.053 0.051 Window 1 copy 4: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID INTERTEK LPB/WPPS-60-01, SHGC 0.28, VT 0.48, [Bldg. Use 1 - Multifamily] (c) 169 ------0.270 0.430 Door 7: Other Door, Swinging, [Bldg. Use 1 - Multifamily]72 ------0.230 0.370 WEST basement west icf: Solid Concrete:8" Thickness, Normal Density, Furring: None, [Bldg. Use 1 - Multifamily] 488 ---22.0 0.042 0.071 wood framed west wall: Wood-Framed, 16" o.c., [Bldg. Use 1 - Multifamily] 2280 30.0 0.0 0.053 0.051 Window 1 copy 3: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID INTERTEK LPB/WPPS-60-01, SHGC 0.28, VT 0.48, [Bldg. Use 1 - Multifamily] (c) 72 ------0.270 0.430 Door 4 copy 2: Other Door, Swinging, [Bldg. Use 1 - Multifamily]24 ------0.230 0.370 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors. (c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 18% better than code Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 202 ofPage COMcheck Software Version 4.1.5.1 Interior Lighting Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Permit No.38763 Construction Site: 238 Dryden Rd Ithaca, NY 14850 Owner/Agent: Todd Fox Visum Development 119 S. Cayuga St 3rd floor Ithaca, NY 14850 607-269-7300 todd@visumdevelopment.com Designer/Contractor: Noah Demarest STREAM Collaborative 108 W. State St 2nd floor Ithaca, NY 14850 607-216-8802 noah@streamcolab.com Project Information Energy Code: 238 Dryden Rd Enhanced Interior Lighting Controls Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Multifamily 9657 0.68 6567 6567Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Multifamily LED 1: B: WALL MOUNT STRIP LIGHT: LED Linear 10W:1 17 10 170 LED 2: H: DOWN LIGHT: LED MR 10W:1 12 10 120 LED 3: D: PENDANT: LED Other Fixture Unit 60W:1 4 60 240 LED 4: F: VANITY LIGHT: LED Linear 11W:1 13 12 156 LED 5: G: ROUND FLUSH MOUNT: LED Panel 60W:1 64 60 3840 LED 6: J: WALL STRIP: LED Linear 10W:1 7 10 70 LED 7: EM1: EMERGENCY LIGHT: LED A Lamp 2.5W:1 18 2 36 LED 8: EM2: EMERGENCY EXIT LIGHT/SIGN: LED A Lamp 2.5W:1 3 2 6 4638Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Interior Lighting PASSES: Design 29% better than code Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 203 ofPage Name - Title Signature Date Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 204 ofPage COMcheck Software Version 4.1.5.1 Exterior Lighting Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Permit No.38763 Construction Site: 238 Dryden Rd Ithaca, NY 14850 Owner/Agent: Todd Fox Visum Development 119 S. Cayuga St 3rd floor Ithaca, NY 14850 607-269-7300 todd@visumdevelopment.com Designer/Contractor: Noah Demarest STREAM Collaborative 108 W. State St 2nd floor Ithaca, NY 14850 607-216-8802 noah@streamcolab.com Project Information Energy Code: 238 Dryden Rd 2 (Residential mixed use area)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) EM EGRESS (Pedestrian and vehicular entrances and exits)6 ft of door 14 Yes 84 PATIOS/BALCONY (Pedestrian and vehicular entrances and exits)9 ft of door 14 Yes 126 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 210 210 400 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures EM EGRESS ( Pedestrian and vehicular entrances and exits 6 ft of door width): Tradable Wattage LED 1: K: EM EGRESS: LED Other Fixture Unit 16W:1 6 14 84 PATIOS/BALCONY ( Pedestrian and vehicular entrances and exits 9 ft of door width): Tradable Wattage LED 2: L1: BALCONY: LED Other Fixture Unit 13W:1 9 9 81 165Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES: Design 73% better than code Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 205 ofPage COMcheck Software Version 4.1.5.1 Mechanical Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Permit No.38763 Location:Ithaca, New York Climate Zone:6a Construction Site: 238 Dryden Rd Ithaca, NY 14850 Owner/Agent: Todd Fox Visum Development 119 S. Cayuga St 3rd floor Ithaca, NY 14850 607-269-7300 todd@visumdevelopment.com Designer/Contractor: Noah Demarest STREAM Collaborative 108 W. State St 2nd floor Ithaca, NY 14850 607-216-8802 noah@streamcolab.com Project Information Energy Code: 238 Dryden Rd Enhanced Interior Lighting Controls Additional Efficiency Package(s) Mechanical Systems List Quantity System Type & Description Split System Heat Pump Heating Mode: Capacity = 15 kBtu/h, Proposed Efficiency = 11.40 HSPF, Required Efficiency = 8.20 HSPF Cooling Mode: Capacity = 13 kBtu/h, Proposed Efficiency = 22.00 SEER, Required Efficiency: 14.00 SEER Fan System: Ducted Unit -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 445 CFM, 1.0 motor nameplate hp, 50.0 fan efficiency grade 9 HVAC System 1 (Single Zone): Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 206 ofPage Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.5.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2018 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR8]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.1 [PR10]1 The vertical fenestration area <= 30 percent of the gross above-grade wall area. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.1 [PR11]1 The skylight area <= 3 percent of the gross roof area. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 207 ofPage Section # & Req.ID Plan Review Complies?Comments/Assumptions C405.5 [PR16]1 Group R-2 dwelling units have separate electrical meters. Complies Does Not Not Observable Not Applicable Requirement will be met. C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 208 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2 [FO4]2 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable Requirement will be met. C105 [FO3]2 Installed slab-on-grade insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.4 [FO7]2 Slab edge insulation depth/length. Slab insulation extending away from building is covered by pavement or >= 10 inches of soil. Complies Does Not Not Observable Not Applicable Requirement will be met. See the Envelope Assemblies table for values. C402.2.6 [FO12]3 Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. See the Envelope Assemblies table for values. C403.12.2 , C403.12.3 [FO9]3 Snow/ice melting system and freeze protection systems have sensors and controls configured to limit service for pavement temperature and outdoor temperature. future connection to controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 209 ofPage Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3, C402.4.3. 4 [FR8]1 Vertical fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.4 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 2.1 [FR19]1 The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability <= 0.004 dfm/ft2. Air barrier penetrations are sealed in an approved manner. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.2, C402.5.4 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.7 [FR17]3 Vestibules are installed on all building entrances. Doors have self-closing devices. Complies Does Not Not Observable Not Applicable Exception: Doors that open directly from a space =3000 ft2. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2010 ofPage Section # & Req.ID Plumbing Rough-In Inspection Complies?Comments/Assumptions C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.7 [PL8]3 Demand recirculation water systems have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2011 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.2.6 [ME41]3 Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.5, C403.2.4. 3 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Refernece section C403.7.7 for operational details. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.11.3 [ME61]2 HVAC piping insulation insulated in accordance with Table C403.11.3. Insulation exposed to weather is protected from damage and is provided with shielding from solar radiation. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.8.4 [ME142]2 Motors for fans that are not less than 1/12 hp and less than 1 hp are electronically commutated motors or have a minimum motor efficiency of 70 percent. These motors have the means to adjust motor speed. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.8.5 [ME143]2 Each DX cooling system > 65 kBtu and chiller water/evaporative cooling system with fans > 1/4 hp are designed to vary the indoor fan airflow as a function of load and comply with detailed requirements of this section. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.12.1 [ME71]2 Systems that heat outside the building envelope are radiant heat systems controlled by an occupancy sensing device or timer switch. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.3 [ME55]2 HVAC equipment efficiency verified.Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C403.2.2 [ME59]1 Natural or mechanical ventilation is provided in accordance with International Mechanical Code Chapter 4. Mechanical ventilation has capability to reduce outdoor air supply to minimum per IMC Chapter 4. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.7.1 [ME59]1 Demand control ventilation provided for spaces >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.7.2 [ME115]3 Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.7.6 [ME141]3 HVAC systems serving guestrooms in Group R-1 buildings with > 50 guestrooms: Each guestroom is provided with controls that automatically manage temperature setpoint and ventilation (see sections C403.7.6.1 and C403.7.6.2). Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2012 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.7.4 [ME57]1 Exhaust air energy recovery on systems meeting Table C403.7.4(1) and C403.7.4(2). Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.7.5 [ME116]3 Kitchen exhaust systems comply with replacement air and conditioned supply air limitations, and satisfy hood rating requirements and maximum exhaust rate criteria. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.11.1 , C403.11.2 [ME60]2 HVAC ducts and plenums insulated in accordance with C403.11.1 and constructed in accordance with C403.11.2, verification may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.4.3. 3.2 [ME121]3 Closed-circuit cooling tower within heat pump loop have either automatic bypass valve or lower leakage positive closure dampers. Open-circuit tower within heat pump loop have automatic valve to bypass all heat pump water flow around the tower. Open- or closed-circuit cooling towers used in conjunction with a separate heat exchanger have heat loss by shutting down the circulation pump on the cooling tower loop. Open- or closed circuit cooling towers have a separate heat exchanger to isolate the cooling tower from the heat pump loop, and heat loss is controlled by shutting down the circulation pump on the cooling tower loop. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.4.1. 4 [ME63]2 Heating for vestibules and air curtains with integral heating include automatic controls that shut off the heating system when outdoor air temperatures > 45F. Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint <= 60F and cooling setpoint >= 80F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C408.2.2. 1 [ME53]3 Air outlets and zone terminal devices have means for air balancing. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.5, C403.5.1, C403.5.2 [ME123]3 Refrigerated display cases, walk-in coolers or walk-in freezers served by remote compressors and remote condensers not located in a condensing unit, have fan-powered condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2013 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.2. 2 [EL22]1 Spaces required to have light- reduction controls have a manual control that allows the occupant to reduce the connected lighting load in a reasonably uniform illumination pattern >= 50 percent. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1, C405.2.1. 1 [EL18]1 Occupancy sensors installed in classrooms/lecture/training rooms, conference/meeting/multipurpose rooms, copy/print rooms, lounges/breakrooms, enclosed offices, open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1. 2 [EL19]1 Occupancy sensors control function in warehouses: In warehouses, the lighting in aisleways and open areas is controlled with occupant sensors that automatically reduce lighting power by 50% or more when the areas are unoccupied. The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.1. 3 [EL20]1 Occupant sensor control function in open plan office areas: Occupant sensor controls in open office spaces >= 300 sq.ft. have controls 1) configured so that general lighting can be controlled separately in control zones with floor areas <= 600 sq.ft. within the space, 2) automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space, 3) are configured so that general lighting power in each control zone is reduced by >= 80% of the full zone general lighting power within 20 minutes of all occupants leaving that control zone, and 4) are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.2, C405.2.2. 1, C405.2.2. 2 [EL21]2 Each area not served by occupancy sensors (per C405.2.1) have time- switch controls and functions detailed in sections C405.2.2.1 and C405.2.2.2. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2014 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL23]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. See code section C405.2.3 Daylight-responsive controls for applicable spaces, C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.4 [EL26]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.4 [EL27]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.5 [EL28]null Automatic lighting controls for exterior lighting installed. Controls will be daylight controlled, set based on business operation time-of-day, or reduce connected lighting > 30%. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.6 [EL26]2 Low-voltage dry-type distribution electric transformers meet the minimum efficiency requirements of Table C405.6. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.7 [EL27]2 Electric motors meet the minimum efficiency requirements of Tables C405.7(1) through C405.7(4). Efficiency verified through certification under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist). Complies Does Not Not Observable Not Applicable Requirement will be met. C405.8.2, C405.8.2. 1 [EL28]2 Escalators and moving walks comply with ASME A17.1/CSA B44 and have automatic controls configured to reduce speed to the minimum permitted speed in accordance with ASME A17.1/CSA B44 or applicable local code when not conveying passengers. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.9 [EL29]2 Total voltage drop across the combination of feeders and branch circuits <= 5%. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2015 ofPage Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Requirement will be met. C105 [IN6]1 Installed above-grade wall insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.3 [IN8]2 Installed floor insulation type and R- value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2016 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.3, C408.2.5. 3 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.8 [FI26]3 Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.2 [FI27]3 HVAC systems and equipment capacity does not exceed calculated loads. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1.1 [FI42]3 Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.4.1. 2 [FI38]3 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1.3 [FI20]3 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2017 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C403.2.4. 2 [FI39]3 Each zone equipped with setback controls using automatic time clock or programmable control system. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2.1, C403.2.4. 2.2 [FI40]3 Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7-day clock, 2- hour occupant override, 10-hour backup Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2.3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C405.5.1 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. C408.1.1 [FI57]1 Building operations and maintenance documents will be provided to the owner. Documents will cover manufacturers' information, specifications, programming procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.1 [FI28]1 Commissioning plan developed by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.3. 1 [FI31]1 HVAC equipment has been tested to ensure proper operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.3. 2 [FI10]1 HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.4 [FI29]1 Preliminary commissioning report completed and certified by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 1 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2018 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 3 [FI43]1 An air and/or hydronic system balancing report is provided for HVAC systems. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 4 [FI30]1 Final commissioning report due to building owner within 90 days of receipt of certificate of occupancy. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2019 ofPage Project Title: Data filename: 238 Dryden Rd U:\2018025 - 238 Dryden Rd - Visum\02.0 APPROVALS\238 ComCheck (1).cck 06/15/21Report date: 2020 ofPage