Loading...
HomeMy WebLinkAboutElevator Report_Ithaca ArthausElectric Elevator Acceptance Inspection & Witness of Test Report #2 MRL Tract Elev 130 Cherry St. Ithaca, NY 13204Owner: Ithaca Arthaus Passenger 3500 2021 Schindler Type Rated Load Year Constructed Manufacturer 9/27/2021 Winslow, Dan E000570 QEITF Date of Report Inspector QEI Certification # QEI Cert. Issuer 210910-00-1949-T Ithaca, City of Workorder Designator Authoritative Jurisdiction Inspection & Test Items Not In Compliance Per ASME A17.1 Failure Reason Phone monitoring not working. Sill pours not completed. Fire resistance rating required to confirm to the building code. FAIDs not tested. Phase 1, Phase 2, Shunt and flood switches not tested. Inspection Item Car Emergency signal Hoistway construction Hoistway construction Fire Service Operation (89-00 ed) FSO Acceptance Checklist Applicable Code Reference Item 1.6 Item 3.10 Item 3.10 Item 6.4 Item 6.5 Test Results Normal Car Operation Empty Car Speed Up: 150 fpm Empty Car Speed Down: 150 fpm Full Car Speed Up: 150 fpm Full Car Speed Down: 150 fpm Load Load Placed on Car: 4375 lbs Safeties F/L Stopping Distance (Car): 0 inches Governor Data Plate: 196 fpm Buffers Runby to CW Buffer: 6.5 inches Miscelaneous Top of Car Clearance: 60 inches Notes Inspected to ASME A17.1 - 2013 and BCNYS - 2016 with 2017 addenda. Inspector's Signature This conveyance inspection was performed in compliance with the applicable provisions of ASME A17.2 Guide for Inspection of Elevators, Escalators, and Moving walks. The owner retains full responsibility to maintain this conveyance in compliance with all applicable laws, ordinances and regulations. The Authority Having Jurisdiction retains all rights and responsibilities, as defined by applicable law, regarding verification of compliance. POSTING INSTRUCTIONS "The most current certificate of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter; or the certificate shall be available for public inspection in the office of the building operator" - Property Maintenance Code THIS CERTIFIES THAT AN INDEPENDENT THIRD-PARTY QEI INSPECTION WAS PERFORMED ON: September 27, 2021 For the following Conveyance: #2 MRL Tract Elev 130 Cherry St. Ithaca, NY 13204 SEE ATTACHED REPORT FOR THE RESULTS OF THIS INSPECTION Authority Having Jurisdiction: Ithaca, City of This Inspection Certificate Expires in: March 2022 This inspection certificate only indicates that a QEI certified inspector employed by CNY Elevator Inspections LLC or ATIS Elevator Inspections LLC performed a conveyance inspection complying with the requirements of the Building Code and Property Maintenance Code on the date indicated. Where non-compliant items are indicated on the attached report and as required by the Authority Having Jurisdiction and/or as required by law, regulation, or ordinance, the Owner shall correct all deficiencies as soon as possible. QEI Inspector: Winslow, Dan QEI # E000570 ATISNY W.O. # 210910-00-1949-T Electric Elevator Acceptance Inspection & Witness of Test Report #1 MRL Tract Elev 130 Cherry St. Ithaca, NY 14850Owner: Ithaca Arthaus Passenger 3500 2021 Schindler Type Rated Load Year Constructed Manufacturer 9/27/2021 Winslow, Dan E000570 QEITF Date of Report Inspector QEI Certification # QEI Cert. Issuer 210910-00-1919-T Ithaca, City of Workorder Designator Authoritative Jurisdiction Inspection & Test Items Not In Compliance Per ASME A17.1 Failure Reason Car flooring and finished sill grout not completed. Phone not working. Standby Power not tested. Car number ID required at bottom and top landing. Fire rating required to conform with Building Code. FAIDs not tested. Not tested. Inspection Item Sills and car floor Car Emergency signal Standby power operation Floor and emergency identification numbering Hoistway enclosure Fire Service Operation (89-00 ed) FSO Acceptance Checklist Applicable Code Reference Item 1.4 Item 1.6 Item 1.17 Item 3.9 Item 4.8 Item 6.4 Item 6.5 Test Results Normal Car Operation Empty Car Speed Up: 150 fpm Empty Car Speed Down: 150 fpm Full Car Speed Up: 150 fpm Full Car Speed Down: 150 fpm Load Load Placed on Car: 4375 lbs Safeties F/L Stopping Distance (Car): 0 inches Governor Data Plate: 197 fpm Trip Speed: 176 fpm Buffers Runby to CW Buffer: 6.75 inches Miscelaneous Top of Car Clearance: 60 inches Notes Inspected to ASME A17.1 - 2013 and BCNYS - 2016 with 2017 addenda. Re-acceptance of previous Acceptance test. See Previous report for additional results.continued on next page #1 MRL Tract Elev 130 Cherry St. Ithaca, NY 14850Owner: Ithaca Arthaus 2 9/27/2021 Winslow, Dan 210910-00-1919-T Page Date of Report Inspector Workorder Designator Inspector's Signature This conveyance inspection was performed in compliance with the applicable provisions of ASME A17.2 Guide for Inspection of Elevators, Escalators, and Moving walks. The owner retains full responsibility to maintain this conveyance in compliance with all applicable laws, ordinances and regulations. The Authority Having Jurisdiction retains all rights and responsibilities, as defined by applicable law, regarding verification of compliance. POSTING INSTRUCTIONS "The most current certificate of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter; or the certificate shall be available for public inspection in the office of the building operator" - Property Maintenance Code THIS CERTIFIES THAT AN INDEPENDENT THIRD-PARTY QEI INSPECTION WAS PERFORMED ON: September 27, 2021 For the following Conveyance: #1 MRL Tract Elev 130 Cherry St. Ithaca, NY 14850 SEE ATTACHED REPORT FOR THE RESULTS OF THIS INSPECTION Authority Having Jurisdiction: Ithaca, City of This Inspection Certificate Expires in: March 2022 This inspection certificate only indicates that a QEI certified inspector employed by CNY Elevator Inspections LLC or ATIS Elevator Inspections LLC performed a conveyance inspection complying with the requirements of the Building Code and Property Maintenance Code on the date indicated. Where non-compliant items are indicated on the attached report and as required by the Authority Having Jurisdiction and/or as required by law, regulation, or ordinance, the Owner shall correct all deficiencies as soon as possible. QEI Inspector: Winslow, Dan QEI # E000570 ATISNY W.O. # 210910-00-1919-T