Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-128 Ithaca Arthaus Product Data Resubmit REVIEWED AND APPROVED
SUBMITTAL TRANSMITTAL Project Name: Ithaca Arthaus Project Number : 18260 A To:Vecino Construction, LLC Date Submitted Attn:Submittal No. (per Procore) X From: Item No. Spec Paragraph / No.Submittal Type Lead Time 1 2 3 4 5 6 7 8 9 10 11 Comments:Resubmitted with .10 design Density Residential Sprinkler Heads Date Transmittal (from SUBCONTRACTOR) 21 05 00 abj Fire Protection Co. East Syracuse, New York 13057 6500 New Venture Gear Dr. Manufacturer 4/2/2020 Nolan Alley Dwg. And/or Specification Section Fire Protection Product Data Title / Description ReSubmitted for Review & Approval REV (1) Submitted for Review & Approval REV (0) This is a FULL SUBMITTAL This is a PARTIAL Submittal Corey Olmstead corey@vecinogroup.com Phone: (315) 854-0979 Signature/Stamp of Transmitter Vecino Construction Stamp BW A&E Stamp Submittal Transmittal PRODUCT SUBMITTAL FIRE PROTECTION (AUTOMATIC FIRE SPRINKLER SYSTEM) ITHACA ARTHAUS 130 CHERRY STREET ITHACA, NY abj’s CONTRACT #20-128 PRODUCT PAGE ___ TYCO DRY PENDENT SPRINKLER HEADS 1 - 8 RELIABLE QUICK RESPONSE UPRIGHTS 9 - 16 RELIABLE RESIDENTIAL PENDENTS 17 - 30 RELIABLE CONCEALED SPACE HEADS 31 - 42 BLACK STEEL PIPING 43 GROOVED COUPLINGS AND FITTINGS 44 - 70 DUCTILE IRON THREADED FITTINGS 71 - 81 CPVC PIPING AND FITTINGS 82 - 111 HANGER MATERIAL 112 - 127 FLOOR CONTROL ASSEMBLY 128 - 130 BUTTERFLY VALVE 131 - 132 FLOW SWITCH 133 - 135 DRY PIPE VALVE 136 - 139 SWING CHECK VALVE 140 - 141 FIRE DEPARTMENT CONNECTION 142 - 143 AUTOMATIC BALL DRIP 144 - 145 DRUM DRIP 146 - 147 BALL VALVE 148 - 149 Series DS-2 Dry-Type Sprinklers 11.2K Pendent Extended Coverage, Light and Ordinary Hazard Page 1 of 8 NOVEMBER 2019 TFP540 IMPORTANTRefer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Improper handling and installation can permanently damage a sprinkler system or its compo-nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com Series DS-2 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite-ria section. Sprinkler Identification Number (SIN) TY5238 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 173-02-E See Table A. (These Approvals apply to the service condition indicated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections1 in. NPT or ISO 7-R 1 Discharge Coefficient See Table D Temperature RatingsSee Table A Finishes Sprinkler: See Table E Escutcheon: See Table E Physical CharacteristicsInlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper Yoke .......................Stainless Steel Casing .............Galvanized Carbon Steel Insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Bulb Seat . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw . . . . . . . . . . . . . . . . .Bronze Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Guide Tube . . . . . . . . . . . . . . . . . Stainless Steel Water Tube . . . . . . . . . . . . . . . . . Stainless Steel Spring .....................Stainless Steel Plug ...............Copper Gasketed SpringPlate Seal ........Beryllium Nickel w/TEFLON Pin ........................Stainless Steel Button Spring . . . . . . . . . . . . . . . Stainless Steel Escutcheon . . . . . . . . . . . . . . . . . . .Carbon Steel General Description TYCO Series DS-2 Dry-Type Sprinklers, 11.2K Pendent, Extended Coverage, Light and Ordinary Hazard (ECLH/ECOH) are decorative glass bulb auto-matic sprinklers typically used where: • pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (for example, sprinkler drops from unheated portions of buildings) • sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (for example, sprinkler drops from wet systems into freezers) NOTICE Series DS-2 Dry-Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica-ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main-taining their fire protection system and devices in proper operating con-dition. Contact the installing contrac-tor or product manufacturer with any questions. Operation When TYCO Series DS-2 Dry-Type Sprinklers, 11.2K Pendent, Extended Coverage, Light and Ordinary Hazard are in service, water is prevented from entering the assembly by the Plug with Gasketed Spring Plate Seal (see Figure 1) in the Inlet of the sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Gasketed Spring Plate Seal from the Inlet allowing the sprinkler to activate and flow water. TFP540 Page 2 of 8 Design Criteria UL and C-UL Listing RequirementsTYCO Series DS-2 Dry-Type Sprin-klers, 11.2K Pendent, Extended Cov-erage, Light and Ordinary Hazard are intended for use in fire sprinkler systems designed in accordance with the extended coverage installa-tion rules recognized by the applica-ble Listing agency (for example, UL Listing is based on NFPA 13 require-ments). See Table C for coverage and flow rate criteria. Temperature Rating Bulb Color Code TY5238 with Flush Escutcheon (Figure 2) with Extended Escutcheon (Figure 4) without Escutcheon (Figure 5) TY5238 with Recessed Escutcheon (Figure 3) SPRINKLER FINISH Natural Brass Chromed Plated Polyester**Natural Brass Chrome Plated Polyester** 135°F (57°C)Orange 1, 2, 3 1, 2, 3 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)*Blue Notes:1. UL Listed (maximum order length of 48 inches)2. C-UL Listed (maximum order length of 48 inches)3. Approved by the City of New York under MEA 173-02-E* 286 °F (141 °C) temperature rating applies to installations in Ordniary Hazard Occupancies only.** Frame and deflector only COMPRESSIONSCREW FRAME INSERT PLUG WITH GASKETED SPRING PLATE SEAL WATER TUBE SPRING CASING BULB SEAT DEFLECTOR BULB GUIDETUBE PLUGSPRING PIN INLET YOKE VENT HOLE INLET BAND FIGURE 1 SERIES DS-2 ECLH/ECOH DRY-TYPE PENDENT SPRINKLER ASSEMBLY TABLE A SERIES DS-2 ECLH/ECOH DRY-TYPE PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP540 Page 3 of 8 UL and C-UL Specific Application Listing Requirements for Installation Under Concrete TeesTYCO Series DS-2 Dry-Type Pendent Sprinklers (TY5238) have a UL and C-UL Specific Application Listing for use under concrete tees when installed as follows: • Stems of the concrete tee construc-tion must be spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 in. (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m). However, where the concrete tee length exceeds 32 feet (9,8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed to ensure that the space between the tees does not exceed 32 feet (9,8 m) in length. • Sprinkler deflectors are to be located in a horizontal plane at or above 1 in. (25,4 mm) below the bottom of the concrete tee stems. • When sprinkler deflectors are located higher than a horizontal plane 1 in. (25,4 mm) beneath the bottom of the concrete tee stems, obstruction to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright sprin-klers applies. Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area(1) 40°F (4°C)50°F (10°C)60°F (16°C) Minimum Exposed Barrel Length(2), Inches (mm) 40°F (4°C)0 0 0 30°F (-1°C)0 0 0 20°F (-7°C)4 (100)0 0 10°F (-12°C)8 (200)1 (25)0 0°F (-18°C)12 (305)3 (75)0 -10°F (-23°C)14 (355)4 (100)1 (25) -20°F (-29°C)14 (355)6 (150)3 (75) -30°F (-34°C)16 (405)8 (200)4 (100) -40°F (-40°C)18 (455)8 (200)4 (100) -50°F (-46°C)20 (510)10 (255)6 (150) -60°F (-51°C)20 (510)10 (255)6 (150) Notes:1. For protected area temperatures that occur between values listed above, use the next cooler temperature2. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). Response Rating Coverage Area(4), ft x ft (m x m) Minimum Flow(1) Light Hazard(2), (0.10 gpm/ft2) gpm (lpm) Minimum Flow(1) Ordinary Hazard Group I(3), (0.15 gpm/ft2) gpm (lpm) Minimum Flow(1) Ordinary Hazard Group II(3), (0.20 gpm/ft2) gpm (lpm) Escutcheon Type Quick 16 x 16 (4,9 x 4,9)30 (114)——Flush, Recessed, Extended Quick 18 x 18 (5,5 x 5,5)33 (125)——Flush, Extended Standard5 20 x 20 (6,1 x 6,1)40 (151)——Flush, Recessed, Extended Quick 14 x 14 (4,3 x 4,3)—30 (148)39 (148)Flush, Recessed, Extended Standard 16 x 16 (4,9 x 4,9)—39 (148)51 (193)Flush, Recessed, Extended Notes:1. Requirement is based on minimum flow in gpm from each sprinkler. The required residual pressure is to based on the use of a K-factor derived from Table D.2. Light Hazard Occupancies are limited to a type of unobstructed construction consisting of flat, smooth ceilings.3. Ordinary Hazard Occupancies may have either “combustible or non-combustible, unobstructed ceiling construction” or “noncombustible obstructed ceiling construction.”4. Minimum spacing between sprinklers is 12.5 feet (3,8 m).5. For retrofit applications of projects installed prior to the NFPA Quick Response / Light Hazard requirement TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS TABLE B UL AND C-UL LISTING COVERAGE AND FLOW RATE CRITERIA TFP540 Page 4 of 8 K-factor LENGTH, Inches (mm) K-factor, gpm/psi1/2 (lpm/bar1/2) 2-1/2 to 6-1/4 (63 mm to 159 mm)11.2 (161,3) 6-1/2 to 10-1/2 (165 mm to 267 mm)11.1 (159,8) 10-3/4 to 14-3/4 (273 mm to 375 mm)11.0 (158,4) 15 to 18-3/4 (381 mm to 476 mm)10.9 (157,0) 19 to 23 (483 mm to 584 mm)10.8 (155,5) 23-1/4 to 26-3/4 (591 mm to 679 mm)10.7 (154,1) 27-1/4 to 31-1/4 (692 mm to 794 mm)10.6 (152,6) 31-1/2 to 35-1/4 (800 mm to 895 mm)10.5 (151,2) 35-1/2 to 39-1/2 (902 mm to 1003 mm)10.4 (149,8) 39-3/4 to 43-1/2 (1010 mm to 1105 mm)10.3 (148,3) 43-3/4 to 48 (1111 mm to 1219 mm)10.2 (146,9) Notes:K-factor Length is determined as follows:• Flush: Order Length from Figure 2 plus 1/2 inch (12,7 mm)• Recessed: Order Length from Figure 3 plus 1/4 inch (6,3 mm)• Extended: Order Length from Figure 4 plus 3-1/4 inch (82,6 mm)• Without Escutcheon: Order Length from Figure 5 minus 2-1/4 inches (57,2 mm) 2-1/4±1/8" (57,2±3,2 mm) ORDER LENGTHS:3" to 48"(76,2 to 1219,2 mm)IN 1/4" (6,4 mm)INCREMENTS **ESCUTCHEON WILL PERMIT ±1/4" (6,4 mm) ADJUSTMENT FACE OF SPRINKLER FITTING FACE OFCEILING 2-3/4" DIA. (69,9 mm) 3-5/8" DIA.(92,1 mm) SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) 1-5/8±1/8"(41,3±3,2 mm) ESCUTCHEON WILL PERMIT ±3/8" (9,5 mm) ADJUSTMENT ORDER LENGTHS:3-1/2" to 48"(88,9 to 1219,2 mm)IN 1/4" (6,4 mm)INCREMENTS ** FACE OF SPRINKLER FITTING FACE OFCEILING 2-3/4" DIA. (69,9 mm) 3-5/8" DIA.(92,1 mm) SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) TABLE D DISCHARGE COEFFICIENTS FIGURE 2 SERIES DS-2 DRY-TYPE PENDENT SPRINKLER (ECLH/ECOH) WITH FLUSH ESCUTCHEON (TY5238) FIGURE 3 SERIES DS-2 DRY-TYPE PENDENT SPRINKLER (ECLH/ECOH) WITH RECESSED ESCUTCHEON (TY5238) TFP540 Page 5 of 8 WRENCHRECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA SPRINKLER WRENCHING AREA ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM2-1/4" (57,2 mm)DEFLECTORTO CEILING FACE OFSPRINKLERFITTING SPRINKLER FITTING(REFER TO DESIGNCRITERIA SECTION) ESCUTCHEON WILL PERMIT ±1-3/8" (34,9 mm) ADJUSTMENT ESCUTCHEONWILL PERMIT±5/8" (15,9 mm)ADJUSTMENT FACE OF SPRINKLER FITTING FACE OFCEILING FOR ORDER LENGTHS< 3-1/4" (82,6 mm):4-7/8±1/8" (123,8±3,2 mm)-or-FOR ORDER LENGTHS 3-1/4" (82,6 mm):5-5/8±1/8" (142,9±3,2 mm) 2-3/4" DIA. (69,9 mm) * ** 3-5/8" DIA.(92,1 mm) * ** ORDER LENGTHS:1" to 45-1/4"(25,4 to 1149,4 mm)IN 1/4" (6,4 mm)INCREMENTS SPRINKLER FITTING(REFER TO DESIGNCRITERIA SECTION) DO NOT FIGURE 4 SERIES DS-2 DRY-TYPE PENDENT SPRINKLER (ECLH/ECOH) WITH EXTENDED ESCUTCHEON (TY5238) FIGURE 5 SERIES DS-2 DRY-TYPE PENDENT SPRINKLER (ECLH/ECOH) WITHOUT ESCUTCHEON (TY5238) FIGURE 6 W-TYPE 17 SPRINKLER WRENCH FIGURE 7 DO NOT GRASP DEFLECTOR TFP540 Page 6 of 8 For wet pipe system installations of 1 in. NPT Series DS-2 Dry-Type Sprin-klers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1 in. x 1 in. NPT Female Adapter (P/N 80145) • 1 in. x 1 in. x 1 in. NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2 1/2 in. reducing tee when locat-ing Series DS-2 Dry-Type Sprinklers directly below the branch line. Oth-erwise, use the configuration shown in Figure 9 to assure complete water drainage from above Series DS-2 Dry-Type Sprinklers and the branchline. Failure to do so may result in pipe freezing and water damage. NOTICE Do not install Series DS-2 Dry-Type Sprinklers into any other type fitting.Failure to use the appropriate fitting may result in one of the following: • failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug • insufficient engagement of the Inlet pipe-threads with consequent leakage DrainageIn accordance with the minimum requirements of the NATIONAL FIRE PROTECTION ASSOCIATION for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem-peratures must be pitched for proper drainage. Exposure LengthWhen using dry sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler’s appropriate exposed barrel length to prevent water from freezing in the con-necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. See Figure 9 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. You can also install Series DS-2 Dry-Type Sprinklers in the 1 in. NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. The configuration shown in Figure 8 is only applicable for wet pipe systems where the sprinkler fitting and water-filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Type Sprinkler has the minimum exposure length depicted in Figure 9. See the Exposure Length section. Sprinkler FittingsInstall 1 in. NPT Series DS-2 Dry-Type Sprinklers in the 1 in. NPT outlet or run of the following fittings: • malleable or ductile iron threaded tee fittings that meet the dimen-sional requirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install Series DS-2 Dry-Type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 10. SIDE OUTLET PLUGGED TO WET SYSTEM FITTING(SEE DESIGN CRITERIASECTION) SPRINKLER DSB-2 BOOT HEATEDAREA AREASUBJECT TOFREEZING RUN OUTLET PLUGGED TO DRY SYSTEM DSB-2 BOOT FITTING(SEE DESIGN CRITERIASECTION) SPRINKLER HEATED AREA (SEE DESIGN CRITERIASECTION) FACE OF SPRINKLER FITTING LENGTHEXPOSURE DSB-2 BOOT INSULATED FREEZER STRUCTURE (ENDS ON OPPOSINGSIDES OF STRAP TIES BOOT) ADHESIVE SHOWN WITH FLUSH ESCUTCHEON DS-2 2-3/4" DIA.(69,9 mm) CLEARANCE HOLE DSB-2 BOOT FIGURE 8 SPRINKLER FITTING HEATED AREA FIGURE 10 SPRINKLER FITTING UNHEATED AREA FIGURE 9 EXPOSURE LENGTH FIGURE 11 MODEL DSB-2 DRY SPRINKLER BOOT WITH SERIES DS-2 DRY-TYPE PENDENT SPRINKLER TFP540 Page 7 of 8 Clearance SpaceIn accordance with NFPA 13, when connecting an area subject to freez-ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and sub-sequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprin-kler Boot, described in Technical Data Sheet TFP591 and shown in Figure 11, can provide the recommended seal. Installation TYCO Series DS-2 Dry-Type Sprin-klers, 11.2K Pendent, Extended Cover-age, Light and Ordinary Hazard must be installed in accordance with this section. General InstructionsSeries DS-2 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Cri-teria section. See the Design Criteria section for other important require-ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. With reference to Figure 7, do not grasp the sprinkler by the deflector. Failure to follow this instruction may impair performance of the device. Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin-kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) rating to 1/8 in. (3,2 mm) for the 360°F (182°C) rating. A leak-tight 1 in. NPT sprinkler joint should be obtained by applying a min-imum-to-maximum torque of 20 to 30 lb-ft (26,8 to 40,2 N·m). Higher levels of torque may distort the sprin-kler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch-eon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Note: Install pendent sprinklers only in the pendent position. The deflector of a pendent sprinkler must be parallel to the ceiling. Step 1. With a non-hardening pipe-thread sealant such as TEFLON applied to the Inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Do not grasp the sprinkler by the deflec-tor, see Figure 7. Step 2. Wrench-tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing, see Figure 1 • a W-Type 17 Sprinkler Wrench on the wrench flat (see Figure 6); apply the wrench recess of the W-Type 17 Sprinkler Wrench to the wrench flat Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 3. After installing the ceiling and applying a ceiling finish, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-2 Dry-Type Sprinklers, 11.2K Pendent, Extended Coverage, Light and Ordinary Hazard must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (see Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage, for example, an improper installation or an ice plug. Close the fire protec-tion system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other-wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin-klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb, see the Installation Section. The owner is responsible for the inspec-tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO-CIATION, such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install-ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec-ommended to be inspected, tested, and maintained by a qualified Inspec-tion Service in accordance with local requirements and/or national codes. TFP540 Page 8 of 8 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON is a registered trademark of DuPont 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 © 2019 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail-ability. When placing an order, indi-cate the full product name, including description and Part Number (P/N). Dry-Type SprinklerWhen ordering Series DS-2 Dry-Type Sprinklers, 11.2K Pendent, Extended Coverage, Light and Ordinary Hazard, specify the following information: • SIN TY5238 • Order Length: Dry-Type Sprinklers are furnished based upon Order Length as measured from the face of the ceiling to the face of the sprinkler fitting, see Figures 2 through 5. After the measurement is taken, round it to the nearest 1/4 in. increment. • Inlet Connections: 1 In. NPT (Standard) ISO 7-R 1 (For information on ISO Inlet Thread Connections, contact your Johnson Controls Sales Representative.) • Temperature Rating • Sprinkler Finish • Escutcheon Type and Finish, as applicable • Part Number from Table E Sprinkler WrenchSpecify W-Type 17 Sprinkler Wrench, P/N 56-010-4-118 Sprinkler BootSpecify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This P/N includes one (1) Boot, two (2) Strap Ties, and 1/3 oz of Adhesive (a sufficient quantity for installing one boot). Notes: 1. Escutcheon Finish applies to sprinklers with escutcheons. 2. 286°F (141°C) temperature rating applies to non-recessed sprin- kler assemblies. 3. Dry-Type Sprinklers are furnished based upon “Order Length” as measured per Figures 2 through 5, as applicable, and for each individual sprinkler where it is to be installed. After the measure- ment is taken, round it to the nearest 1/4 inch increment.* Use Prefix “I” for ISO 7-R 1 Connection (e.g., I-61-431-1-372). P/N* 61 – XXX – X – XXX ORDER LENGTH(3) 055 5.50 in. 082 8.25 in. 180 18.00 in. 187 18.75 in. 372 37.25 in. 480 48.00 in. SPRINKLER FINISH ESCUTCHEON FINISH(1) 0 CHROME PLATED SIGNAL WHITE (RAL9003) POLYESTER 1 NATURAL BRASS SIGNAL WHITE (RAL9003) POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER SIGNAL WHITE (RAL9003) POLYESTER 5 NATURAL BRASS BRASS PLATED 9 CHROME PLATED CHROME PLATED TEMPERATURE RATING(2) 0 135°F (57°C) 1 155°F (68°C) 2 175°F (79°C) 3 200°F (93°C) 4 286°F (141°C) SIN 40 Pendent with Flush Escutcheon TY5238 (Figure 2) 41 Pendent with Recessed Escutcheon TY5238 (Figure 3) 42 Pendent with Extended Escutcheon TY5238 (Figure 4) 43 Pendent without Escutcheon TY5238 (Figure 5) TABLE E SERIES DS-2 EXTENDED COVERAGE DRY-TYPE SPRINKLERS PART NUMBER SELECTION Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR Series Quick Response Glass Bulb Sprinklers Bulletin 014 Rev. M Bulletin 014 Rev. M Model F1FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1FR40 Sprinkler Types Standard Spray Pendent Model F1FR42, F1FR40, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1FR56LL & F1FR42LL NSF Certifi ed Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. Vertrauen durch Sicherheit (VdS) 5. NSF Certified to NSF/ANSi Standard 61 Annex G (NSF) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Pendent Conventional Recessed Pendent/F1/F2 Upright Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall RecessedPendent/FP Concealed Pendent XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP Product Description Reliable Model F1FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model F1FR56 Conventional sprinkler which is an Old-style/Conven- tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. 2. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used:• Pendent, recessed pendent, upright, horizontal side- wall, and vertical sidewall defl ectors• K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric)• Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. 3. Design and Installation Information Model Nominal K-factor Nominal Orifi ce Diameter Defl ector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 D RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 D RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D RA1410 cULus, NSF Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 D RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 "Conventional (Pendent or Upright)"2.25 57 D RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 D RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright)2.25 57 D RA1485 cULus, FM, LPCB 1,2,3,9 (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3) Available with FM approved Polyester coating in black or white. (4) Available with LPCB and VdS approved Polyester coating. (5) VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (6) Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (7) cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) 4. Listed and Approved Temperature Ratings Model Defl ector/ Orientation Ordinary Temp. Classifi cation 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classifi cation 150°F (65°C) Max. Ambient Temp. High Temp. Classifi cation 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb F1FR28 Pendent cULus Recessed Pendent cULus -- Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS -- F1FR42 Pendent cULus Recessed Pendent cULus -- Upright cULus F1FR42LL Pendent -- cULus, NSF -- Recessed Pendent -- cULus, NSF -- F1FRXLH Pendent cULus Recessed Pendent cULus -- Upright cULus F1FR56 Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- Concealed Pendent* cULus cULus,VdS,EC cULus -- Upright cULus, FM, LPCB, VdS, EC “Conventional (Pendent or Upright)”LPCB, VdS, EC F1FR56LL Pendent -- cULus, NSF -- Recessed Pendent -- cULus, NSF -- Concealed Pendent* -- cULus, NSF -- F1FR56 Horizontal Sidewall cULus, FM Recessed Horizontal Sidewall cULus, FM -- F1FR56 Vertical Sidewall (Pen- dent or Upright)cULus, FM, LPCB * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Defl ector/ Orientation Listed and Approved Recessed Escutcheons SIN Model F1 (Fig. 1 & 3) 3/4-inch (19mm) adjustment Model F2 (Fig. 1 & 3) 1/2-inch (12.7mm) adjustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC cULus, FM, LPCB, VdS, EC cULus, VdS, EC RA1414 F1FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 5. Fig. 1 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon Fig. 2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 6. Fig. 3 Model F1FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon Fig. 4 Model F1FR56/F1FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate 7. Fig. 5 - Model F1FR56/F1FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model F1FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate (1) Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6)White Painted Special Application Finishes Sprinkler Escutcheon Cover plate (1) Electroless Nickel PTFE(7) Electroless Nickel PTFE Bright Brass Bright Brass(3)Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(6)Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull (1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed “corrosion resistance” applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as “Polyester coated” applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. (7) cULus listed Corrosion Resistant Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Defl ector:CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup:CDA Alloy 651 or 693 Washer:Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb:Glass Ordering Information Specify: 1. Sprinkler Model: [F1FR28][F1FR40][F1FR42] [F1FR42LL][F1FRXLH][F1FR56][F1FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent][Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] 9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by RecycledPaper Revision lines indicate updated or new data. EG. Printed in U.S.A. 06 /15 P/N 9999970300 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 176 Rev. CBulletin 176 Rev. C Model F1 Residential Sprinklers for Design Density of .10 gpm/ft2 Model F1 Res Sprinklers Listed to meet the minimum design density as required by UL1626. Types: 1. F1 Res 30 Pendent 2. F1 Res 30 Recessed/F2 3. F1 Res 30 Recessed/FP 4. F1 Res 30 CCP Pendent 5. F1 Res 49 Pendent 6. F1 Res 49 Recessed Pendent/F1 7. F1 Res 49 Recessed Pendent/FP 8. F1 Res 49 CCP Pendent 9. F1 Res 58 Pendent 10. F1 Res 58 Recessed Pendent/F1 11. F1 Res 58 Recessed Pendent/FP 12. F1 Res 58 CCP Pendent 13. F1 Res 44 & 58 HSW 14. F1 Res 44 & 58 HSW Recessed HSW/F2 15. F1 Res 58 HSWX 16. KRes58 HSWX 17. F1 Res 44 SWC 18. F1 Res 76 Pendent 19. F1 Res 76 Recessed Pendent/F1 20. F1 Res 76 Recessed Pendent/FP 21. F1 Res 76 CCP Pendent F1 Res 30, 49, 58 & 76 Recessed Pendent/F1 The 3mm glass-bulb pendent sprinklers permit the ef- ficient use of residential water supplies for sprinkler cover- age in residential fire protection design. Upon fire conditions, rising heat causes a sprinkler’s heat-sensitive glass-bulb to shatter, releasing the water- way for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass-bulb • Sprinkler Frame : Brass Casting • Sprinklers’ Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: ½” NPT (R1/2) • K-Factor: 3.0 (Actual) - F1 Res 30 Pendent Sprinkler 4.9 (Actual) - F1 Res 49 Pendent Sprinkler 5.8 (Actual) - F1 Res 58 Pendent & HSW/HSWX Sprinkler 7.6 (Actual) - F1 Res 76 Pendent Sprinkler 4.4 (Actual) - F1 Res 44 HSW Sprinkler • Density: Minimum 0.10 gpm/ft2 F1 Res 30, 49, 58 & 76 Recessed Pendent/FP F1 Res 30, 49, 58 & 76 CCP Pendent F1 Res 44 & 58 Recessed HSW/F2Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model F1 Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model F1 Res 44 SWC Sprinkler Patent Pending - Model F1 Res 76 Pendent Sprinkler Product Description Model F1Res Pendent sprinklers (Figs. 1, 2, 3 & 4) combine excellent durability, high sensitivity glass-bulb and low profile decorative design. F1 Res 44 SWC F1 Res 58 HSWX 2. K=7.6) that will provide lower pressure demands for 0.1 gpm/ft2 densities in NFPA 13 residential applica- tions. Example No. 1 Room Size= 12 ft x 20 ft (3.6 m x 6.1 m) Coverage Area= 12 x 20 = 240 ft2 (22.3 m2) Flow @ 0.10 gpm/ft2 density= 240 x 0.10 = 24 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (24/4.9)2 = 24 psi (1.65 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) cover- age area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). There- fore, the minimum flow required is 24 gpm @ 24 psi (90.8 L/min @ 1.65 bar). Example No. 2 Room Size= 8 ft x 20 ft (2.4 m x 6.1 m) Coverage Area= 8 x 20 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (16/4.9)2 = 10.7 psi (0.74 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) cover- age area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Therefore, the minimum flow required is 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Example No. 3 Room Size= 10 ft x 16 ft (3.0 m x 4.91 m) Coverage Area= 10 x 16 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 76 Pendent Sprinkler, K=7.6 The baseline flow for a 16 ft x 16 ft coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Example No. 4 Room Size= 14 ft x 18 ft (4.3 m x 5.5 m) Coverage Area= 14 x 18 = 252 ft2 (23.6 m2) Flow @ 0.10 gpm/ft2 density= 252 x 0.10 = 25.2 gpm (94.6 L/min) Using an F1 Res 76 Pendent Sprinkler, K=7.6 Pressure= (252/7.6)2 = 11 psi (0.76 bar) The baseline flow and pressure of an 18 ft x 18 ft cover- age area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 25.2 gpm @ 11 psi (94.6 L/min @ 0.76 bar). In general residential sprinklers require fl ows and pressures as listed for 0.05 densities to achieve the proper spray pattern so the fl ows and pressures at 0.05 density are the baseline fl ows and pressures. Flows and pressures below the listed 0.05 density shall not be used. Application Model F1 Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. When using F1 Residential Sprinklers for systems designed to NFPA 13D or NFPA 13R, use listed area of coverage and minimum flow and pressure requirements shown in Bulletin 135. For systems designed to NFPA 13, use information in this bulletin. The number of design sprinklers shall be the most hydraulically demanding sprinklers as required by NFPA 13. Flows and pressures can not be below the baseline flows and pressures. NFPA 13 For residential sprinkler systems designed to NFPA 13, a minimum density of 0.1 gpm/ft2 must be provided over the “design area” that includes the four (4) hydraulically most demanding sprinklers for the actual coverage areas being protected by the 4 sprinklers. The minimum required dis- charge from each of the four most hydraulically demanding sprinklers shall be the greater of the following: 1. The flow rates given in the Reliable Residential Sprinkler Technical Bulletins referenced in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area (for actual coverage areas less than or between those indicated in the respective technical bulletin, it is re- quired to use the minimum required flow for the next largest coverage area); or 2. A minimum discharge density of 0.1 gpm/ft2 applied over the “design area” consisting of the four most hy- draulically demanding sprinklers for the actual cov- erage areas being protected by the four sprinklers. The maximum dimension of the actual coverage area cannot be any greater than the maximum coverage area indicated in the technical bulletins referenced in Table A. Design Note: Using the As = S x L method to de- termine the sprinkler protection area of coverage in accordance with NFPA 13, apply the 0.1 gpm/ft2 den- sity to this area to determine the minimum required flow. Compare this flow to the minimum 0.05 gpm/ft2 cULus Listed flow for the appropriate coverage area in the technical bulletin for the specific residential sprinkler. If the flow stated in the technical bulletin is less than the calculated 0.1 gpm/ft2 density flow required, the .1 density flow must then be used in the equation Q=KP, solving for P, to establish the mini- mum required pressure using the sprinkler K-factor. Note: In many cases the listed flow of individual resi- dential sprinklers may exceed the required minimum 0.05 gpm/ft2 density. Reliable has available resi- dential sprinklers with larger K-factors (K=5.8 and 3. Installation Models F1 Res sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Mod- el F1 Res sprinklers. Use of any other recessed escutch- eon will void all approvals and warranties. For installing Model F1 Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models F1 Res Recessed Pendent, CCP sprinklers use only the Model GFR2 sprin- kler wrench; for installing Model F1 Res recessed HSW sprinklers use only the Model GFR2 Sprinkler wrench. Use of wrenches other than those specified may dam- age these sprinklers. Note: A ‘leak tight” sprinkler joint can be obtained with the following torque: • 3/4” NPT (R3/4) – 14-20 ft-lbs (19 - 27.1 N-m) • ½” NPT (R1/2) – 8-18 ft-lbs (10.8 – 24.4 N-m) Do not tighten sprinklers over maximum recom- mended torque. It may cause leakage or impairment of the sprinklers. F1 escutcheon, 3/4” (19mm) adjustment • Model F1 Res 30, 49, 58 & 76 Pendent • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / F1/F2 Note: See escutcheon table for dimensions. Fig. 1 Fig. 2 **Baseline fl ows and pressures for 0.05 density Defl ector - to - ceiling Maximum 1” (25mm) to 4” (100mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5x5.5) 17 (64.3) 12.0 (0.83) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) 4. Technical Data: F1 Res 49 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C 1/2” NPT (R1/2)7/16” (11)155 175 68 79 175 (12)100 150 38 66 4.9 2.25 (57) Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fi tting to ceiling Inch (mm) F1 3/4” (19.0)Min.= 3/4 (19.1)Max.=11/2 (38.1) 3/16 - 15/16 (4.7 - 24.0) F2 1/2” (12.7)Min.= 15/16 (23.8) Max.=11/2 (38.1) 3/16 - 11/16 (4.7 - 17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 & 58 Recessed Pendent Sprinkler *Defl ector - to - ceiling Maximum 4” (100mm) to 8” (203mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 15 (57) 9.4 (0.65) R3516 14 x 14 (4.3x4.3) 16 (60.5) 10.6 (0.73) 16 x 16 (4.9x4.9) 17 (64.3) 12.0 (0.83) 18 x 18 (5.5x5.5) 19 (72) 15.0 (1.0) 20 x 20 (6.1x6.1) 22 (83.2) 20.2 (1.4) *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth = 7” (178mm) 2. Beam spacing at or greater than 7.5 ft. (2.3m) on center. Technical Data: F1 Res 58 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm) °F °C °F °C ½” NPT (R½) ½” (13) 155 175 68 79 175 (12)100 150 38 66 5.8 2.25 (57) **Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Ceiling -to-Defl ector Inch (mm) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 16 (61) 7.6 (0.53) 1-4 (25-100)R3513 14 x 14 (4.3x4.3) 16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9) 16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) **Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2) 175 (12) 155 175 68 79 100 38 3.0 2.25 (57) **Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12 (3,6) 8 (30,3) 7.0 (0,48) 8 (30,3) 7.0 (0,48) 1 to 4 (25 to 100);½ recessed using F2 escutcheon 8 (2,4)14 x 14 (4,3 x 4,3) 14 (4,3) 10 (37,8) 11 (0,76) 10 (37,8) 11 (0,76) For Ceiling types refer to NFPA 13, 13R or 13D **Calculate for a .10 density but in no case go below the baseline flows & pressures 5. Technical Data: F1 Res 76 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C 3/4” NPT(R3/4)17/32 (13.5)155175 6879 175 (12)100150 3866 7.6 2.25 (57) Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fi tting to ceiling Inch (mm) F1 3/4 (19.0)Min.= 3/4 (19.1) Max.=11/2 (38.1)3/16 - 15/16 (4.7 - 24.0) F2 1/2 (12.7)Min.= 15/16 (23.8) Max.=11/2 (38.1)3/16 - 11/16 (4.7 - 17.4) *Calculate for a .10 density but in no case go below the baseline flows & pressures *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 21 7.6 (0.53) R7618 14 x 14 (4.3x4.3) 21 7.6 (0.53) 16 x 16 (4.9x4.9) 21 7.6 (0.53) 18 x 18 (5.5x5.5) 21 7.6 (0.53) 20 x 20 (6.1x6.1) 23 9.2 (0.63) • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / FP • Model F1 Res 30, 49, 58 & 76 CCP Pendent* Fig. 3 Fig. 4 NOTE: The F1 Res 76 will use a 1” x ¾” reducer. FP push-on/thread-off escutcheon* Not listed for corrosion resistance. 6. Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent / FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ½” NPT (R½)7/16” (11) 155 68 135 57 175 (12) 100 38 4.9 2.25 (57) CCP Options Data: “A” Cover Adjustment Inch (mm) “B” CCP Height Inch (mm) 1/2 (12.7)15/16 (24) 3/16 (4.7)3/4 (19) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9) 14 (53) 8.2 (0.56) 18 x 18 (5.5x5.5) 18 (68.1) 13.5 (0.93) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) FP Data “A”: FP Position “A” Inch (mm) Max. Recessed 7/16 (11) Min. Recessed 15/16 (24) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for in- stallation in ceilings which have positive pressure in the space above. Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ½” NPT (R½) ½ (13) 155 68 135 57 175 (12) 100 38 5.8 2.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 16 (61) 7.6 (0.53) R3513 14 x 14 (4.3x4.3) 16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9) 16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) *Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2) 175 (12) 135 57 100 38 3.0 2.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12 (3,6) 8 (30,3) 7.0 (0,48) 1 to 4 (25 to 100); ½ (13mm) recessed using FP escutcheon 8 (2,4)14 x 14 (4,3 x 4,3) 14 (4,3) 11 (37,8) 13.4 (0,92) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a .10 density but in no case go below the baseline flows & pressures 7. *Calculate for a .10 density but in no case go below the baseline flows & pressures F1 Res 44 & 58 Recessed HSW/F2 • Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58 Recessed HSW/F2 Technical Data: F1 Res 44 HSW & HSW/F2 Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)3/8 (10)155 175 68 79 175 (12)100 150 38 66 4.4 2.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2 1/2 (13) 3/16 - 11/16 (4.7 - 17.4) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Sprinkler Temp. Rating °F (°C) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 155 (68) 175 (79) 12 (45.4) 7.5 (0.52) R3531 14 x 14 (4.3x4.3) 155 (68) 175 (79) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 16 (60.6) 13.3 (0.92) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 18 (68.1) 16.8 (1.16) 18 x 18 (5.5x5.5) 155 (68) 175 (79) 19 (72.0) 18.7 (1.29) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 155 (68) 175 (79) 14 (53.0) 10.2 (0.71) 14 x 14 (4.3x4.3) 155 (68) 175 (79) 16 (60.6) 13.3 (0.92) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 17 (64.4) 15.0 (1.04) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 20 (75.7) 20.7 (1.43) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1.89) *Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ¾” NPT (R3/4)17/32” (13.5)155 175 68 79 135 57 175 (12) 100 150 38 66 7.6 2.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 21 7.6 (0.53) R7618 14 x 14 (4.3x4.3) 21 7.6 (0.53) 16 x 16 (4.9x4.9) 21 7.6 (0.53) 18 x 18 (5.5x5.5) 22 8.4 (0.58) 20 x 20 (6.1x6.1) 25 10.8 (0.74) 8. Technical Data: F1 Res 44 SWC Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Cover Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ½” NPT (R½)3/8 (10) 155 68 135 57 175 (12) 100 38 4.4 2.45 (62) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 13 (49.2) 8.7 (0.60) R3531 14 x 14 (4.3x4.3) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9x4.9) 17 (64.3) 15.0 (1.1) 16 x 18 (4.9x5.5) 19 (71.8) 18.7 (1.13) 16 x 20 (4.9x6.1) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 14 (52.9) 10.2 (0.71) 14 x 14 (4.3x4.3) 15 (56.7) 11.7 (0.81) 16 x 16 (4.9x4.9) 18 (68.1) 16.8 (1.16) 16 x 18 (4.9x5.5) 20 (75.6) 20.7 (1.43) • Model F1 Res 44 SWC* Fig. 5 *Calculate for a .10 density but in no case go below the baseline flows & pressures * Not listed for corrosion resistance. 9. Technical Data: F1 Res 58 HSW & HSW/F2 Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)½ (13)155 175 68 79 175 (12)100 150 38 66 5.8 2.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2 ½ (13) 3/16 - 11/16 (4.7 - 17.4) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Sprinkler Temp. Rating °F (°C) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 155 (68) 175 (79) 16 (60.6) 7.6 (0.53) R3533 14 x 14 (4.3x4.3) 155 (68) 175 (79) 18 (68.2) 9.7 (0.67) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 21 (79.5) 13.2 (0.91) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 25 (94.7) 18.6 (1.28) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 29 (109.8) 25 (1.73) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 155 (68) 175 (79) 22 (83.3) 14.4 (1.0) 14 x 14 (4.3x4.3) 155 (68) 175 (79) 22 (83.3) 14.4 (1.0) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 26 (98.4) 20.1 (1.39) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 31 (117.4) 28.6 (1.97) *Calculate for a .10 density but in no case go below the baseline flows & pressure 10. Technical Data: F1Res 58 HSWX (SIN RA3533) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) Sprinkler Identifi cation Number (SIN)°F °C °F °C Bulb ½” NPT (R½)1/2” (13) 175 (12) 155 175 68 79 100 150 38 66 5.8 2.45 (62) RA3533 *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C) Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 18 x 20 (5,5 x 6,1) 18 (5,5) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 4 to 6 (100 to 152);½ (13) recessed using F2 escutcheon 8 (2,4) 20 x 20 (6,1 x 6,1) 20 (6,1) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 16 x 22 (4,9 x 7,3) 16 (4,9) 33 (125) 32.4 (2,23) 33 (125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16 (4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14 (4,3) 42 (160) 52.4 (3,75) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18 (5,5) 35 (133) 36.4 (2,5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) recessedusing F2 escutcheon 16 x 22 (4,9 x 6,7) 16 (4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16 (4,9) 42 (160) 52.4 (3,6) 42 (160) 52.4 (3,6) 14 x 26 (4,3 x 7,9) 14 (4,3) 46 (174) 62.9 (4,34) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. • Model F1 Res 58 HSWX (Bulb) • Model KRes58 HSWX (Link) Fig. 6 Technical Data: KRes58 HSWX (RA3593) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) Sprinkler Identifi cation Number (SIN)°F °C Link ½” NPT (R½)1/2” (13) 175 (12) 100 38 5.8 2.45 (62) RA3593 *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (165°F/74°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 18 x 20 (5,5 x 6,1) 18 (5,5) 29 (109) 25 (1,72) 4 to 6 (100 to 152);½ (13) recessed using F2 escutcheon 8 (2,4) 20 x 20 (6,1 x 6,1) 20 (6,1) 30 (114) 26.8 (1,85) 16 x 22 (4,9 x 7,3) 16 (4,9) 33 (125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16 (4,9) 38 (144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14 (4,3) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18 (5,5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) Recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16 (4,9) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16 (4,9) 42 (160) 52.4 (3,6) 14 x 26 (4,3 x 7,9) 14 (4,3) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. 11. Maintenance Model F1 Res 30, 49, F1 Res 58 & F1 Res 76 Sprin- klers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprin- klers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper op- eration or non-operation. Model F1Res 30, 49 & 58 Pendent Sprinkler Specifi cations Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pen- dent sprinklers engineered to provide a minimum de- sign density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the appli- cable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance list- ing shall be 1” to 8” maximum. Sprinkler frame and de- flector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb con- taining no plastic parts, and having a temperature rat- ing of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 49 & 58, SIN R3516 & R3513 (Bulletin 135). *DuPont Registered Trademark 12. Model F1 Res 30, 49 & 58 Recessed Pendent/F1, Model F1 Res 30, 49 & 58 Recessed Pendent/F2, Model F1 Res 30, 49 & 58 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s instal- lation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1” to 8” maximum. Sprinkler frame and deflector shall be of bronze frame construction hav- ing a ½” NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Model F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residen- tial recessed pendent sprinklers shall be Reliable [Model F1 Res 49 & 58 Recessed Pendent/F1] [Model F1 Res 49 & 58 Recessed Pendent/F2] [Model F1 Res 49 & 58 Recessed Pendent/FP] SIN R3516 & R3513 (Bulletin 135). Model F1 Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer’s installa- tion guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Meth- od of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Con- cealed pendent sprinklers shall be Reliable Model F1 Res 49 & 58 CCP, SIN R3516 & R3513 (Bulletin 135). Model F1 Res 44, F1 Res 58 Horizontal Sidewall, F1 Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifi cations Sprinklers shall be [cULus Listed] low flow residen- tial horizontal sidewall sprinklers engineered to pro- vide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in con- formance with the manufacturer’s installation guide- lines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprin- kler frame and deflector shall be of bronze frame con- struction having a ½” NPT thread. Water seal assem- bly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2” adjustment (Model F2) standard finish should be Bright Chrome and white painted. The F1 Res 58 HSW is also available with low lead frame. F1 Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and F1 Res 44 a nomi- nal K factor of 4.4. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish– specify]. Residential horizontal sidewall sprinklers shall be Reli- able Model F1 Res 44, F1 Res 58, F1 Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). *DuPont Registered Trademark Model F1 Res 44 & 58 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 58 horizontal sidewall sprinkler with the following modifications: Re- place “horizontal sidewall sprinkler” with “recessed hori- zontal sprinkler.” Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½” adjust- ment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish– specify]. Resi- dential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 58/F2, SIN R3513 (Bulletin 135). Model F1 Res 76 Pendent Sprinklers shall be [cULus Listed] low flow resi- dential pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the list- ed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plat- ed] [White Polyester] [Special finish– specify]. Residen- tial pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, Model F1 Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residen- tial recessed pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer’s technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Mod- el F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Stan- dard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/F1] [Model F1 Res 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer’s installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 76 CCP, SIN R7618 (Bulletin 135). Finishes(1) Standard Finishes Sprinkler F1, F2, FP Escutcheons Bronze Chrome Plated White Polyester Coated(2) Brass Bright Chrome Plated White Painted Special Application Finishes Sprinkler F1,F2,FP Escutcheons Electroless NickelPTFE(Teflon®)*(2) Bright Brass Black Plated Black Paint Off White Chrome Dull Electroless NickelPTFE (Teflon®)* Bright Brass Black Plated Black Paint Off White Chrome Dull (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus listed Corrosion Resistant. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 13. *DuPont Registered Trademark The Reliable Automatic Sprinkler Co., Inc.(800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 03 /14 P/N 9999970322 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 044 Rev. BBulletin 044 Rev. B Features 1. cULus Listed for areas of coverage up to 256 square feet. 2. Six foot minimum installation distance be- tween sprinklers. 3. Sprinkler may be installed on the same branch line that supplies sprinklers below ceiling. 4. Nominal K-factor of 5.6 (80 metric). 5. Quick Response Sprinkler. 6. 212°F (100°C) Temperature Rating 7. ½” NPT Installation Thread Product Description Reliable’s Model KFR-CCS Combustible Concealed Space Sprinkler is a quick response, upright, specific-ap- plication sprinkler designed to provide protection of specific light hazard combustible and non-combustible concealed spaces requiring sprinkler protection. The KFR-CCS sprin- kler complies with NFPA 13 criterion for the protection of combustible concealed spaces. The Model KFR-CCS Sprinkler utilizes a fast response solder-link fusible element. It has demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This feature enables the sprinkler to apply water to a fire much faster than standard sprinklers of the same temperature rating. Application The Model KFR-CCS Sprinkler is designed for installation into: A. CPVC Pipe** – Wet Sprinkler Systems B. Steel Pipe – Wet or Dry Sprinkler Systems **The Model KFR-CCS Sprinkler is UL Listed for use with UL Listed CPVC Pipe and UL Listed CPVC Fittings. The allowable system construction types include: • Wood truss (12” to 36” deep) • Non-Combustible Bar Joist (12” to 36” deep) • Solid Wood (12” maximum depth) or Composite Wood Joist (12” maximum depth) • All systems are limited to an above-sprinkler (ceiling) horizontal slope of 2:12. The performance of the Model KFR-CCS Sprinkler in com- bustible concealed spaces was clearly evident during the full scale fire testing of this product. Concealed spaces between floors, as well as low pitch at- tics (slope of 2:12 or less) are inherently shallow. Standard spray sprinklers, by design, have an umbrella-like spray pat- tern that poses a difficult challenge when trying to achieve effective coverage within a shallow space. The Model KFR- CCS Sprinkler addresses the difficult “above ceiling” fire challenge for both wet pipe and dry pipe sprinkler systems. WARNING Model KFR-CCS Combustible Concealed Sprinklers de- scribed herein must be installed and maintained in compli- ance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities having ju- risdiction. Failure to do so may impair the performance of these devices. The property owner is responsible for main- taining their fire protection system and devices in proper op- erating condition. The installing contractor or manufacturer should be contacted with any questions. Design Specifi cations A. CPVC Pipe Sprinkler Systems (Refer to Figs. 2 & 3) The Model KFR-CCS Sprinkler is designed to be in- stalled into CPVC pipe sprinkler systems. It is listed to provide fire sprinkler protection of combustible con- cealed areas where the construction methods consist of: 1. Wood trusses or non-combustible bar joists (Refer to Fig. 2) 2. Non-combustible, insulation filled solid wood or composite wood joists** (Refer to Fig. 3) Model KFR-CCS 56 Combustible Concealed Space Upright Sprinkler Sprinkler Identifi cation Number (SIN): RA4454 Model KFR-CCS Fig. 1 2. Sprinkler Components Technical Data Sprinkler Identifi cation Number (SIN) Discharge Coeffi cient (K factor)Response Thread size Max. Working Pressure Min. Working Pressure Temperature Rating Fusible Element Color Finish Approvals English Metric English Metric English Metric English Metric RA4454 5.6 80 Quick Response ½ NPT 175psi 12bar 7psi 0.48 bar 212°F 100°C Green Bronze cULus Listed* *cULus Listing applies only for the installations and conditions indicated in the “Design Specifications” Section of this bulletin. Material Data (Refer to Fig. 1): Frame Defl ector Load Screw Cup Sealing Washer Strut Lever Fusible Element Ejection Spring Brass Brass Brass Bronze Nickel Alloy coated with PTFE Adhesive Tape Stainless Steel Stainless Steel Nickel Alloy Stainless Steel **Note: In order to be considered “non-combustible, insu- lation filled, solid wood or composite wood joists” construction, the insulation (including insulation provided with a combustible vapor barrier), must completely fill the pockets between the joists to the bottom of the joists. Also, the insulation must be secured into place with metal wire netting. The metal wire netting is intended to hold the insula- tion in place should the insulation become wet by the operation of Model KFR-CCS Sprinklers in the event of a fire. In order to use the CPVC pipe and fittings, the horizontal runs of pipe must be a maximum of 6 in (0.15 m) above the ceiling or noncombustible ceiling insulation, or 1/3 the depth of concealed space (as measured from the top surface of the ceiling to the bottom of the deck above), whichever is smaller (Refer to Figs. 2 & 3). The CPVC piping can then be used to supply the Model KFR-CCS Sprinklers, as well as the sprinklers installed be- low the ceiling. Unless modified by this technical data sheet, all other guidelines provided by the CPVC pipe and fittings manufactures must be followed. When using 1 in (DN25) or larger pipe, a hanger must be located at the truss nearest a sprig for purposes of restraint. If using 3/4 in (DN19) piping, all sprigs over 12 in (0.30 m) must be laterally braced using methods described in the NFPA standards. Where the CPVC must be offset up and over an obstruction and the pipe exceeds the allowed hori- zontal positioning requirements specified above as well as shown in Figs. 2 and 3, additional Model KFR-CCS Sprin- klers are to be installed to protect the CPVC products. A min- imum lateral distance of 18 in (0.46 m) must be maintained between the CPVC pipe and heat pumps, fan motors, and heat lamps. Concealed Space Area: The area of the concealed space is not limited; however, for both Figs. 2 and Fig. 3 where CPVC pipe is being utilized, draft-curtains or full height walls must be provided at 1,000 ft2 (93 m2) areas. This draft curtain shall be at least 1/3 the depth of the concealed space or 8 in (0.2 m), whichever is greater, and be constructed using a material that will not al- low heat to escape through or above the draft curtain. Concealed Space Size: The depth of the concealed space is limited to 12 in (0.30 m) minimum and 36 in (0.91 m) maximum. System Type: Light hazard, wet pipe system. Minimum Installation Distance (Spacing) Between Sprinklers: 6 ft (1.83 m) (Note:This minimum spacing does not apply to any ad- ditional sprinklers that are required for protection of CPVC piping that is offset over an obstruction) Maximum Distance (Spacing) Between Sprinklers: 14 ft (4.27 m) for concealed spaces constructed of wood trusses or non-combustible bar joists that are between 12 in (0.30 m) and less than 18 in (0.46 m) in depth. 14 ft (4.27 m) for concealed spaces constructed of solid wood joists or composite wood joists where the concealed space is in between 12 in (0.30 m) and 36 in (0.91 m) in depth. 16 ft (4.88 m) for concealed spaces constructed of wood trusses or non-combustible bar joists that are between 18 in (0.46 m) and to 36 in (0.91 m) in depth. Maximum Coverage Area Per Sprinkler: 196 ft2 (18.21 m2) for concealed spaces constructed of wood trusses or non combustible bar joists that are between 12 in (0.30 m) and less than 18 in (0.46 m) in depth. 196 ft2 (18.21 m2) for concealed spaces constructed of sol- id wood joist or composite wood joist where the concealed space is in between 12 in (0.30 m) and 36 in (0.91 m) in depth. 256 ft2 (23.78 m2) for concealed spaces constructed of wood trusses or non-combustible bar joists that are between 18 in (0.46 m) and 36 in (0.91 m) in depth. Note: Sprinkler spacing is determined by the depth of the concealed space at the location of the installation. When transitions occur in the concealed space, the sprin- klers may immediately be spaced at the largest approved coverage area per the listing for the concealed space depth (Refer to Fig. 8) Defl ector Position: 1.5 in (0.04 m) minimum to 4 in (0.10 m) maximum below upper deck or underside of insulation in insulation-filled solid joist and composite joist construction (Refer to Figs. 2 & 3) Minimum Distance Away From Face of Wood Truss or Top Chord of Bar Joist 4.5 in (0.11 m) (Refer to Fig. 2) Remote Area: 1,000 ft2 (92.90 m2) (Note: Additional sprinklers that are required for protec- tion of CPVC piping that is offset over an obstruc- tion do not need to be included in the remote area.) Required Density: 0.10 gpm/ft2 (4.08 Lpm/m2) Minimum Operating Pressure: 7 psi (0.48 bar) Obstruction Rules: All obstruction criteria per the applicable version of NFPA 13 apply, unless modified by this Bulletin (Refer to Fig. 7). The KFR-CCS is classified as an Extended Coverage Up- right Spray Sprinkler when installed in locations where the maximum coverage area per sprinkler exceeds 225 ft2. The KFR-CCS is classified as a Standard Upright Spray Sprinkler when installed in locations where the maximum coverage area per sprinkler is 225 ft2 or less. B. Steel Pipe Systems (Refer to Figs. 4, 5 & 6) The Model KFR-CCS Sprinkler is designed to be in- stalled into steel pipe sprinkler systems. It is listed to provide fire sprinkler protection of combustible con- cealed areas where the construction methods consist of: 1. Wood trusses or non-combustible bar joists (Refer to Fig. 4) 2. Solid wood joist construction where the upper deck and ceiling joists may have a maximum depth of 12 in (0.30 m) and typical on-center joist spacing of a minimum of 16 in (0.41 m). (Refer to Fig. 5). 3. Non-combustible, insulation-filled, solid wood or composite wood joists** (Refer to Fig. 6) **Note: In order to be considered “non-combustible, insu- lation-filled, solid wood or composite wood joists” construction, the insulation (including insulation provided with a combustible vapor barrier), must completely fill the pockets between the joists to the bottom of the joists. Also, the insulation must be se- cured into place with metal wire netting. The metal wire netting is intended to hold the insula- tion in place should the insulation become wet by the operation of Model KFR-CCS Sprinklers in the event of a fire. Concealed Space Area: The area of the concealed space is not limited; however, for wood truss construction or concealed spaces of non- combustible bar joist construction (Refer to Fig. 4) draft- curtains or full height walls must be provided at 1,000 ft2 (93 m2) areas. This draft curtain shall be at least 1/3 the depth of the concealed space or 8 in (0.2 m), whichever is greater, and be constructed using a material that will not allow heat to escape through or above the draft curtain. For solid wood joist construction (Refer to Fig. 5), blocking must be provide in each upper deck and ceiling joist chan- nel at a maximum 32 ft (9.75 m) intervals. This blocking shall be installed to the full depth of the joist and be installed so as to not allow heat to escape through or above the blocking. The blocking must be constructed using a non-combustible material. Draft curtains must be protrude below the joist 3. 4. a minimum of 6 in (0.15 m) or 1/3 the space, whichever is greatest and run parallel with the joist spaced at 31 ft (9.45 m) width maximum to limit the area to a maximum of 1,000 ft2 (93 m2). The draft curtain may be constructed of ¼ in (6.4 m) plywood to prevent heat from escaping beyond the area. For non-combustible, insulation-filled, solid wood joist or composite wood joist construction (Refer to Fig. 6), the re- quirement for draft curtains or blocking does not apply. Concealed Space Size: For wood truss construction or non-combustible bar joist construction the depth of the concealed space is limited to 12 in (0.30 m) minimum and 36 in (0.91 m) maximum (Refer to Fig. 4). For solid wood joist, non-combustible, insulation-filled solid wood or composite wood joist construction the depth of the concealed space is limited to 6 in (0.15 m) minimum and 36 in (0.91 m) maximum. This distance is measured from the top of the ceiling joists to the bottom of the upper deck joists (Refer to Figs. 5 & 6). System Type: Light hazard, wet or dry pipe system. Minimum Installation Distance (Spacing) Between Sprinklers: 6 ft (1.83 m) Maximum Distance (Spacing) Between Sprinklers: 14 ft (4.27 m) for concealed spaces constructed of wood trusses or non-combustible bar joists that are between 12 in (0.30 m) and less than 18 in (0.46 m) in depth. 14 ft (4.27 m) for concealed spaces constructed of solid wood joists or composite wood joists where the concealed space is in between 6 in (0.15 m) and 36 in (0.91 m) in depth. 16 ft (4.88 m) for concealed spaces constructed of wood trusses or non-combustible bar joists that are between 18 in (0.46 m) and to 36 in (0.91 m) in depth. Maximum Coverage Area Per Sprinkler: 196 ft2 (18.21 m2) for concealed spaces constructed of wood trusses or non combustible bar joists that are be- tween 12 in (0.30 m) and less than 18 in (0.46 m) in depth. 196 ft2 (18.21 m2) for concealed spaces constructed of solid wood joist or composite wood joist where the con- cealed space is in between 6 in (0.15 m) and 36 in (0.91 m) in depth. 256 ft2 (23.78 m2) for concealed spaces constructed of wood trusses or non-combustible bar joists that are between 18 in (0.46 m) and 36 in (0.91 m) in depth. Note: Sprinkler spacing is determined by the depth of the concealed space at the location of the installation. When transitions occur in the concealed space, the sprin- klers may immediately be spaced at the largest approved coverage area per the listing for the concealed space depth (Refer to Fig. 8) Defl ector Position: 1.5 in (0.04 m) minimum to 4 in (0.10 m) maximum below the upper deck for concealed spaces constructed of wood trusses or non-combustible bar joists (Fig. 4). 1.5 in (0.04 m) minimum to 2 in (0.05 m) maximum be- low the bottom of the upper joist for concealed spaces con- structed of solid wood joists (Fig. 5). 1.5 in (0.04 m) minimum to 4 in (0.10 m) maximum be- low the bottom of the upper joist for concealed spaces con- structed of non-combustible insulation filled solid wood or composite wood joists (Fig. 6). Minimum Distance Away From Face of Wood Truss or Top Chord of Bar Joist 4.5 in (0.11 m) (Refer to Fig. 4) Remote Area: The remote area for wood truss construction, non-combus- tible bar joist construction (Refer to Fig. 4) and solid wood joist construction (Refer to Fig. 5) is 1,000 ft2 (92.90 m2) for wet pipe systems or 1,300 ft2 (120.77 m2) for dry pipe sys- tems. The remote area for non-combustible insulation filled solid wood joist or composite wood joist construction is to be cal- culated per the requirements of the applicable version of NFPA 13 (Refer to Fig. 6). Required Density: 0.10 gpm/ft2 (4.08 Lpm/m2) Minimum Operating Pressure: 7 psi (0.48 bar) Obstruction Rules: All obstruction criteria per the applicable version of NFPA 13 apply, unless modified by this Bulletin (Refer to Fig. 7). The KFR-CCS is classified as an Extended Coverage Up- right Spray Sprinkler when installed in locations where the maximum coverage area per sprinkler exceeds 225 ft2. The KFR-CCS is classified as a Standard Upright Spray Sprinkler when installed in locations where the maximum coverage area per sprinkler is 225 ft2 or less. Installation Instructions Model KFR-CCS Sprinklers are to be installed in the up- right position with their frames arms parallel with the pipe’s run (Refer to Figs. 2 through 6). When installing the Model KFR-CCS sprinkler use only the Reliable Model D installation wrench. Usage of any other type of installation wrench may damage the sprinkler and will immediately void the manu- facture’s warranty. Note: A leak tight ½” NPT (R1/2) sprinkler joint can be ob- tained with an installation torque of approximately 8 -18 ft-lbs (10.8 – 24.4 N-m). Do not tighten sprin- klers over these recommended limits. Doing so may cause premature leakage and or operation. Maintenance Model KFR-CCS Sprinklers should be inspected and main- tained in accordance with the applicable version of NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non- operation. 5.Fig. 2 6.Fig. 3 Fig. 47. 8.Fig. 5 9.Fig. 6 Fig. 7 10. Fig. 811. Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by RecycledPaper Revision lines indicate updated or new data. EG. Printed in U.S.A. 08/14 P/N 9999970449 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection schedule 10 and schedule 40 Nps Nom oD Nom ID NomINaL WaLL NomINaL WeIGHT UL pIeCes in.mm in.mm in.mm lbs. / ft.kg / m Crr*Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1 ¼1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1 ½1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). sCHeDULe 40 speCIFICaTIoNs Proprietary mill coating ensures clean, corrosion-resistant surface Outperforms and outlasts standard lacquer-coated pipe Easily painted, without special preparation Available with hot-dip galvanizing Also available in black Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe are subjected to the toughest possible testing to ensure the highest possible quality — not to mention reliable, long-lasting performance. High quality, high performance schedule 10 and schedule 40 meet or exceed These standards: • UL, C-UL and FM Listed • FM Approved • ASTM A135, Type E, Grade A (Schedule 10) • ASTM A53, Type E, Grade B (Schedule 40 5–6) • ASTM A795, Type E, Grade A (Schedule 40) • NFPA 13 NomINaL sIze oD sCHeDULe 40 in.Wall Inches Wt. lbs. / ft. Wt. / Ft. H2o Filled 1 1.315 .133 1.68 2.055 1 ¼1.660 .140 2.27 2.922 1 ½1.900 .145 2.72 3.602 2 2.375 .154 3.66 5.109 2 ½2.875 .203 5.80 7.871 3 3.500 .216 7.58 10.783 3 ½4.000 .226 9.12 — 4 4.500 .237 10.80 16.311 5 5.563 .258 14.63 23.262 6 6.625 .280 18.99 31.498 Nps Nom ID WT. / FT. LBs.WT. / FT. H20 FILLeD pCs. / LIFT WT. / LIFT 21'WT. / LIFT 24'WT. / LIFT 25' 1 ¼1.442 1.807 2.514 61 2315 2645 2756 1 ½1.682 2.087 3.049 61 2673 3055 3183 2 2.157 2.640 4.222 37 2051 2344 2442 2 ½2.635 3.534 5.895 30 2226 2544 2651 3 3.260 4.336 7.949 19 1730 1977 2060 4 4.260 5.619 11.789 19 2242 2562 2669 5 5.295 7.780 17.309 13 2124 2427 2529 6 6.357 9.298 23.038 10 1953 2232 2325 8 8.249 16.96 40.086 7 2493 2849 2968 TeCHNICaL DaTa CHarT WeIGHTs aND DImeNsIoNs CHarT Nps Nom oD Nom ID NomINaL WaLL NomINaL WeIGHT UL pIeCes in.mm in.mm in.mm lbs. / ft.kg / m Crr*Lift 1 ¼1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1 ½1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 2 ½2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). sCHeDULe 10 speCIFICaTIoNs GRINNELL G-FIRE Figure 577 Grooved Rigid Coupling 1 to 12 Inch (DN25 to DN300) Page 1 of 4 NOVEMBER 2014 TFP1854 Worldwide Contacts www.tyco-fire.com General Description The GRINNELL G-FIRE Figure 577 Grooved Rigid Couplings provide a rigid joint by firmly gripping along the full circumference of the pipe grooves. Figure 577 couplings are a proven de-pendable method of joining pipe and are an economical alternative to weld-ing, threading, or using flanges. Figure 577 couplings are rated at pressures up to 350 psi (24, 1 bar) de-pending on pipe size and wall thick-ness when used in fire protection ser-vice applications. Refer to Table A. NOTICE The GRINNELL G-FIRE Figure 577 Grooved Rigid Coupling described herein must be installed and main-tained in compliance with this docu-ment, as well as with the applicable standards of the Approval agency, in addition to the standards of any other authorities having jurisdiction. Failure to do so may result in serious person-al injury or impair the performance of these devices. Never remove any piping component nor correct or modify any piping de-ficiencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal inju-ry, property damage, and/or impaired device performance. It is the designer’s responsibility to se-lect products suitable for the intend-ed service and to ensure that pressure ratings and performance data are not exceeded. Material and gasket selec-tion should be verified to be compati-ble for the specific application. Always read and understand the installation instructions. The owner is responsible for maintain-ing their mechanical system and de-vices in proper operating condition. The installing contractor or device manufacturer should be contacted with any questions. Technical Data ApprovalsUL and ULC Listed FM Approved VdS Approved LPCB (Cert. Nos. 669a and 673a) Refer to Table A for details. Sizes1 to 12 Inch (DN25 to DN300) HousingDuctile iron conforming to ASTM A536, Grade 65-45-12 Finish• Orange non-lead paint • Red non-lead paint • Hot-dipped, Galvanized conforming to ASTM A153 Bolts/Nuts• ANSI: Carbon Steel oval neck track head bolts are heat-treated and conform to the physical properties of ASTM A183 Grade 2 and SAE J429 Grade 5 with a minimum tensile strength of 110,000 psi. Carbon Steel heavy hex nuts con-form to the physical properties of ASTM A183 Grade 2 and SAE J995 Grade 5. Bolts and nuts are zinc-electroplated conforming to ASTM B633. Stainless Steel bolts and nuts are available upon request. • Metric: Carbon Steel oval neck track head bolts (Gold color coded) are heat-treated and conform to the physical properties of ASTM F568M with a minimum tensile strength of 760 MPa. Carbon Steel heavy hex nuts con-form to the physical properties of ASTM A563M Class 9. Bolts and nuts are zinc-electroplated con-forming to ASTM B633. Gaskets• Pre-lubricated Grade “A” EPDM, Violet color code, -30°F to 150°F (-34°C to 66°C) For dry and freezer systems, lubri-cation is required. Refer to Installa-tion Manual IH-1000FP for details. • Tri-Seal Grade “E” EPDM, Green color code, -30°F to 230°F (-34°C to 110°C) For proper gasket selection, refer to Technical Data Sheet TFP1895. For Fire Protection pressure rating, listing, and approval information, contact your TYCO Representative. TFP1854 Page 2 of 4 Pipe Size Max.b Pressures psi (bar) Max.b End Load Lbs. (kN) Max.a, d End Gap Inches (mm) Nominal Dimensions Coupling Bolts Approx. Weight Lbs. (kg) Nominal ANSI Inches DN O.D. Inches (mm) AInches (mm) BInches (mm) CInches (mm)Qty.Sizec Inches (mm) 1DN25 1.315(33,7)350(24,1)475(2,11)0.06(1,5)1.63(41)3.92(100)1.65(42)2 3/8 x 2-1/4M10 x 57 1.2(0,55) 1-1/4DN32 1.660(42,4)350(24,1)757(3,37)0.06(1,5)2.66(68)4.40(112)1.64(42)2 3/8 x 2-1/4M10 x 57 1.3(0,59) 1-1/2DN40 1.900(48,3)350(24,1)992 (4,41)0.06(1,5)2.90(74)4.66(118)1.66(42)2 3/8 x 2-1/4M10 x 57 1.5(0,68) 2DN50 2.375(60,3)350(24,1)1,551 (6,90)0.06(1,5)3.38(86)5.20(132)1.70(43)2 3/8 x 2-1/4M10 x 57 1.8(0,82) 2-1/2DN65 2.875(73,0)350(24,1)2,272 (10,11)0.06(1,5)3.88(99)5.64(143)1.75(44)2 3/8 x 2-1/4M10 x 57 2.0(0,91) –DN65 3.000(76,1)350(24,1)2,474 (11,01)0.06(1,5)4.00(102)5.78(147)1.75(44)2 —M10 x 57 2.0(0,91) 3DN80 3.500(88,9)350(24,1)3,367 (14,98)0.06(1,5)4.50(114)6.33(161)1.75(44)2 3/8 x 2-1/4M10 x 57 2.7 (1,22) 4DN100 4.500(114,3)300(20,7)4,771 (21,22)0.06(1,5)5.70(145)7.50(191)1.83(46)2 3/8 x 2-1/4M10 x 57 3.3(1,50) –DN125 5.500(139,7)300(20,7)7,127 (31,71)0.125(3,2)6.80(173)8.75(222)1.91(49)2 —M12 x 76 5.3(2,41) 5DN125 5.563(141,3)300(20,7)7,290 (32,43)0.125(3,2)6.86(174)8.82(224)1.91(49)2 1/2 x 3M12 x 76 5.3(2,41) –DN150 6.500(165,1)300(20,7)9,955 (44,28)0.125(3,2)7.80(198)9.75(248)1.91(49)2 —M12 x 76 5.7(2,59) 6DN150 6.625(168,3)300(20,7)10,341 (46,00)0.125(3,2)8.47(215)9.88(251)1.91(49)2 1/2 x 3M12 x 76 5.9(2,68) 8DN200 8.625(219,1)300(20,7)17,528 (77,97)0.125(3,2)10.25(260)12.78(325)2.40(61)2 5/8 x 3-1/4M16 x 83 11.7(5,32) 10e DN250 10.750(273,0)300(20,7)27,229 (121,0)0.25(6,4)12.50(318)16.50(419)2.56(65)2 3/4 x 4-3/4M20 x 121 19.5(8,86) 12e DN300 12.750(323,9)300(20,7)38,303 (170,0)0.25(6,4)14.50(368)18.50(470)2.56(65)2 3/4 x 4-3/4M20 x 121 22.0(10,00) a. Maximum available gap between pipe ends. Minimum gap = 0.b. Maximum Pressure and End Load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ for other pipe materials and/or wall thickness. Contact your TYCO Representative.c. Gold color coded metric bolts and nuts are available upon request.d. Max End Gap is for cut grooved standard weight pipe.e. For 10 inch and 12 inch sizes where VdS Approval is required, refer to Figure 772, Technical Data Sheet G140. CB A FIGURE 1 G-FIRE FIGURE 577 GROOVED RIGID COUPLING, 1 TO 12 INCH (DN25 TO DN300) NOMINAL DIMENSIONS TFP1854 Page 3 of 4 Pipe Sizes Nominal ANSI Inches(O.D. mm) Pipe Schedulec Pressure Ratingpsi(bar) UL ULC FM 1 (33,7) 10 300(20,7)300(20,7)350(24,1) 40 350(24,1)350(24,1)350(24,1) 1-1/4 (42,4); 1-1/2 (48,3); 2 (60,3); 2-1/2 (73,0) 10 350(24,1)350(24,1)350(24,1) 40 350(24,1)350(24,1)350(24,1) 3 (88,9); 4 (114,3) 10 300(20,7)300(20,7)350(24,1) 40 300(20,7)300(20,7)350(24,1) 5 (141,3); 6 (168,3); 8 (219,1)a; 10 (273,0)a; 12 (323,9)b 10 300(20,7)300(20,7)300(20,7) 40 300(20,7)300(20,7)300(20,7) Pipe Sizes Nominal ANSI Inches(O.D. mm) Pipe Specificationd Pressure Ratingpsi(bar) LPCB VdS 1 (33,7); 1-1/4 (42,4); 1-1/2 (48,3); 2 (60,3); — (76,1); 3 (88,9); 4 (114,3); — (165,1)ISO 65 Medium 290(20)— 6 (168,3); 8 (219,1); 10 (273,0); 12 (323,9)ISO 4200 Wall Thickness 5,4 mm 290(20)— 1 (33,7); 1-1/4 (42,4); 1-1/2 (48,3); 2 (60,3); — (76,1); 3 (88,9); 4 (114,3); — (139,7); 6 (168,3); 8 (219,1)DIN 2448 or 2548 —232(16) a. For 8 and 10 inch sizes, minimum allowed pipe wall thickness is 0.188 inchesb. For 12 Inch, Schedule 30 is minimum allowed pipe wall thickness by UL and ULC. 0.250 inch wall thickness is the minimum allowed by FMc. See Agency website for Listing/Approvals of other pipe specifications: UL website - see Online Certificate Directory, www.ul.com FM Global website - www.approvalguide.com d. See Agency website for Listing/Approvals of other pipe specifications: LPCB website - see Search Our Listings - Automatic Sprinklers, Water Spray and Deluge Systems, www.redbooklive.com VdS website - see certifications, www.vds.de Pipe O.D. mm Pipe Specificationc Pressure Ratingpsi(bar) UL FM 76,1 ISO 4200 Type F 300(20,7)350(24,1) ISO 4200 Type D and E 300(20,7)300(20,7) EN 10255 Heavy 300(20,7)300(20,7) EN 10255 Medium 300(20,7)300(20,7) 139,7 ISO 4200 Type D, E, and F 300(20,7)300(20,7) EN 10255 Heavy 300(20,7)300(20,7) EN 10255 Medium 300(20,7)300(20,7) 165,1 EN 10255 Heavy 300(20,7)300(20,7) EN 10255 Medium 300(20,7)300(20,7) TABLE A LISTED/APPROVED PRESSURE RATINGS GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP1854 Page 4 of 4 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. Care and Maintenance The GRINNELL G-FIRE Figure 577 Grooved Rigid Coupling must be maintained in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys-tem from the proper authorities and notify all personnel who may be af-fected by this decision. After placing a fire protection system in service, notify the proper authorities and advise those responsible for mon-itoring proprietary and/or central sta-tion alarms. The owner is responsible for the in-spection, testing, and maintenance of their fire protection system and devic-es in compliance with this document, as well as with the applicable stan-dards of the National Fire Protection Association (e.g., NFPA 25), in addi-tion to the standards of any authority having jurisdiction. Contact the install-ing contractor or product manufac-turer with any questions. Any impair-ments must be immediately corrected. Automatic sprinkler systems are rec-ommended to be inspected, tested, and maintained by a qualified Inspec-tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure GRINNELL Products are available glo-bally through a network of distribution centers. For the nearest distributor, visit www.tyco-fire.com. When plac-ing an order, indicate the full product name. Specify: G-FIRE Figure 577 Grooved Rigid Coupling, quantity, pipe size (Nominal ANSI or O.D.), finish (Or-ange, Red, or Galvanized), and type of gasket: • Pre-lubricated Grade “A” EPDM • Tri-Seal Grade “E” EPDM Page 5 of 6 TFP1810 Figures 391, 392, 393, 312 and 313 Figure 341 E to E Figure 327 C to E C to E Figure 393 E to E Figure 392 E to E Figure 391 E to E Figure 313C to E C to E Figure 341 150 lbs. Flange Adapter C to E Appx. Wt. E to E Appx. Wt. nches Lbs. Inches Lbs. mm kg. mm kg. 2.75 2.0 4.00 2.8 69.6 0.9 101.6 1.3 2.75 2.2 4.00 3.2 69.9 2.0 101.6 1.5 3.25 2.7 4.0 5.2 82.6 1.2 101.6 2.4 3.75 5.0 4.00 8.0 95.3 2.3 101.6 3.6 4.25 7.1 4.00 10.2 108.0 3.2 101.6 4.6 5.00 11.9 6.00 17.2 127.0 5.4 152.4 7.8 5.50 17.1 6.00 21.4 139.7 7.8 152.4 9.7 6.50 27.5 6.00 26.0 165.1 12.5 152.4 11.8 7.75 47.0 6.00 38.4 196.9 21.3 152.4 17.4 9.00 68.0 8.00 65.0 228.6 30.8 203.2 29.5 10.00 107.0 8.00 91.0 254.0 48.5 203.2 41.3 Nominal Size 11/4" 11/2" 2" 21/2" 3" 4" 5" 6" 8" 10" 12" Figure 327 Cross Figures 391, 392 and 393 Adapter Nipples E to E Appx. Wt. C to E Appx. Wt. C to E Appx. Wt. Inches Lbs. Inches Lbs. Inches Lbs. mm Kg. mm Kg. mm Kg. 4.00 0.8 1.75 0.4 1.38 0.4 101.6 0.4 44.5 0.2 35.1 0.2 4.00 0.9 1.75 0.5 1.38 0.5 101.6 0.4 44.5 0.2 35.1 0.2 4.00 1.2 1.88 0.6 1.38 0.6 101.6 0.5 47.8 0.3 35.1 0.3 4.00 1.9 2.00 0.7 1.50 1.1 101.6 0.9 50.8 0.3 38.1 0.5 4.00 2.5 2.25 1.4 1.50 1.2 101.6 1.1 57.2 0.6 38.1 0.5 6.00 5.5 2.63 2.4 1.75 2.2 152.4 2.5 66.8 1.1 44.5 1.0 6.00 7.4 2.88 4.1 2.00 3.3 152.4 3.4 73.2 1.9 50.8 1.5 6.00 9.5 3.13 5.6 2.00 4.6 152.4 4.3 79.5 2.5 50.8 2.1 6.00 14.2 3.88 11.1 2.00 8.7 152.4 6.4 98.6 5.0 50.8 3.9 8.00 27.0 4.38 14.0 2.13 9.1 203.2 12.2 11.3 6.4 54.1 4.1 8.00 33.0 4.88 22.0 2.25 16.7 203.2 15.0 124.0 10.0 57.2 7.6 Nominal Size 11/4" 11/2" 2" 21/2" 3" 4" 5" 6" 8" 10" 12" Figure 312 Figure 313 221/2° Elbow 11 1/4° Elbow Figures 327 and 341 Figure 312 C to E C to E General Notes: It is the Designer’s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application.Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Page 6 of 6 TFP1810 Figure 321 Figure 321 C to E C to E 11⁄2 x 11⁄2 x 11⁄4 6 x 6 x 4 2 x 2 x 11⁄2 6 x 6 x 5 21⁄2 x 21⁄2 x 11⁄4 8 x 8 x 2 21⁄2 x 21⁄2 x 11⁄2 8 x 8 x 3 21⁄2 x 21⁄2 x 2 8 x 8 x 4 3 x 3 x 11⁄2 8 x 8 x 5 3 x 3 x 2 8 x 8 x 6 3 x 3 x 21⁄2 10 x 10 x 2 4 x 4 x 11⁄4 10 x 10 x 3 4 x 4 x 11⁄2 10 x 10 x 4 4 x 4 x 2 10 x 10 x 5 4 x 4 x 21⁄2 10 x 10 x 6 4 x 4 x 3 10 x 10 x 8 5 x 5 x 2 12 x 12 x 3 5 x 5 x 21⁄2 12 x 12 x 4 5 x 5 x 3 12 x 12 x 5 5 x 5 x 4 12 x 12 x 6 6 x 6 x 2 12 x 12 x 8 6 x 6 x 21⁄2 12 x 12 x 10 6 x 6 x 3 Figure 321 Reducing Tee Nominal C to E Appx. Wt. Nominal C to E Appx. Wt. Size Inches Lbs. Size Inches Lbs. Inches mm Kg.Inches mm Kg. 3.25 2.0 6.50 26.6 82.6 0.9 165.1 12.1 3.25 2.7 6.50 27.0 82.6 1.2 165.1 12.2 3.75 4.2 7.75 36.2 95.3 1.9 196.9 16.4 3.75 4.2 7.75 36.5 95.3 1.9 196.9 16.6 3.75 4.3 7.75 36.6 95.3 2.0 196.9 16.6 4.25 5.3 7.75 36.8 108.0 2.4 196.9 16.7 4.25 5.5 7.75 37.0 108.0 2.5 196.9 16.8 4.25 5.8 9.00 57.1 108.0 2.6 228.6 25.9 5.00 9.8 9.00 57.4 127.0 4.4 228.6 26.0 5.00 9.9 9.00 57.6 127.0 4.5 228.6 26.1 5.00 10.1 9.00 57.8 127.0 4.6 228.6 26.2 5.00 10.3 9.00 58.0 127.0 4.7 228.6 26.3 5.00 10.5 9.00 58.4 127.0 4.8 228.6 26.5 5.50 14.5 10.00 80.2 139.7 6.6 254.0 36.4 5.50 14.8 10.00 80.5 139.7 6.7 254.0 36.5 5.50 15.2 10.00 80.7 139.7 6.9 254.0 36.6 5.50 15.8 10.00 80.9 139.7 7.2 254.0 36.7 6.50 26.5 10.00 91.4 165.1 11.9 254.0 41.5 6.50 26.5 10.00 91.8 165.1 12.0 254.0 41.6 6.50 26.5 165.1 12.0 GRINNELL G-FIRE Grooved Fittings, Ductile Iron Worldwide Contacts www.tyco-fire.com Page 1 of 26 JANUARY 2016 TFP1815 For Fire Protection pressure rating, listing and approval information, contact Tyco Fire & Building Products. General Description GRINNELL G-FIRE Grooved Fittings provide an economical and efficient method of changing direction, adding an outlet, reducing, or capping piping systems. The G-FIRE grooved fittings are available in ductile iron or fabri-cated steel as indicated. Note: Figure 510S and 519S fittings are special short radius fittings with smaller center to end dimensions than stan-dard grooved fittings. Depending on the size and coupling used, there may be interferences at the bolt pads that require repositioning of the coupling orientation. The use of flange adapters is not recommended with Figures 510S and 519S fittings. Contact TYCO Fire Protection Products for details. NOTICE Never remove any piping component nor correct or modify any piping defi-ciencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal injury, property damage, and/or impaired device performance. It is the designer’s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data are not exceeded. Material and gasket selection should be verified to be compatible for the specific applica-tion. Always read and understand the installation instructions. The GRINNELL G-FIRE Grooved Fittings described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the approval agency, in addition to the standards of any other authorities having jurisdiction. Failure to do so may result in serious personal injury or impair the perfor-mance of these devices. The owner is responsible for maintain-ing their system and devices in proper operating condition. Contact the install-ing contractor or product manufacturer with any questions Technical Data ApprovalsUL and ULC Listed FM ApprovedVdS Approved LPCB Cert. No. 669aMaterialCast: Ductile iron conforming to ASTM A536, Grade 65-45-12 Protective Coatings• Non-lead orange paint (USA) • RAL red or non-lead paint (EMEA and APAC) • Hot dipped galvanized conforming to ASTM A153 Care and Maintenance The following inspection procedure must be performed as indicated, in addition to any specific requirements of the NFPA. Any impairments must be immediately corrected. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this decision. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa-tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac-tor or product manufacturer with any questions. Automatic sprinkler systems are rec-ommended to be inspected, tested, and maintained by a qualified Inspec-tion Service in accordance with local requirements and/or national codes. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni-toring proprietary and/or central station alarms. TFP1815 Page 2 of 26 1. Figure 550 is available for the America market only. Nominal Pipe Size Figure 250 Cast Figure 350 Fabricated Figure 550(1) Cast ANSI Inches (DN) O.D. Inches (mm) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 1-1/4 x 1 (32 x 25)1.66 x 1.31 (42,4 x 33,4)2.50 (63,5)0.7 (0,3)——2.50 (63,5)0.7 (0,3) 1-1/2 x 1 (40 x 25)1.90 x 1.31 (48,3 x 33,4)——2.50 (63,5)0.7 (0,3)—— 1-1/2 x 1-1/4 (40 x 32)1.90 x 1.66 (48,3 x 42,4)2.50 (63,5)0.8 (0,3)——2.50 (63,5)0.8 (0,3) 2 x 1 (50 x 25)2.37 x 1.31 (60,3 x 33,4)——2.50 (63,5)0.9 (0,4)—— 2 x 1-1/4 (50 x 32)2.37 x 1.66 (60,3 x 42,4)——2.50 (63,5)0.9 (0,4)—— 2 x 1-1/2 (50 x 40)2.37 x 1.90 (60,3 x 48,3)——2.50 (63,5)1.0 (0,5)—— 2-1/2 x 1 (65 x 25)2.87 x 1.31 (73,0 x 33,4)——2.50 (63,5)1.2 (0,5)—— 2-1/2 x 1-1/4 (65 x 32)2.87 x 1.66 (73,0 x 42,4)2.50 (63,5)1.4 (0,6)——2.50 (63,5)1.4 (0,6) 2-1/2 x 1-1/2 (65 x 40)2.87 x 1.90 (73,0 x 48,3)2.50 (63,5)1.4 (0,6)——2.50 (63,5)1.4 (0,6) 2-1/2 x 2 (65 x 50)2.87 x 2.37 (73,0 x 60,3)2.50 (63,5)1.3 (0,6)——2.50 (63,5)1.3 (0,6) 76mm x 1-1/4 (65 x 32)3.00 x 1.66 (76,1 x 42,4)2.50 (63,5)1.4 (0,6)——2.50 (63,5)1.4 (0,6) 76mm x 1-1/2 (65 x 40)3.00 x 1.90 (76,1 x 48,3)2.50 (63,5)1.4 (0,6)——2.50 (63,5)1.4 (0,6) 76mm x 2 (65 x 50)3.00 x 2.37 (76,1 x 60,3)2.50 (63,5)1.5 (0,7)——2.50 (63,5)1.5 (0,7) 3 x 1 (80 x 25)3.50 x 1.31 (88,9 x 33,4)——2.50 (63,5)1.3 (0,6)—— 3 x 1-1/4 (80 x 32)3.50 x 1.66 (88,9 x 42,4)——2.50 (63,5)1.3 (0,6)—— 3 x 1-1/2 (80 x 40)3.50 x 1.90 (88,9 x 48,3)2.50 (63,5)1.8 (0,8)——2.50 (63,5)1.8 (0,8) 3 x 2 (80 x 50)3.50 x 2.37 (88,9 x 60,3)2.50 (63,5)1.7 (0,8)——2.50 (63,5)1.7 (0,8) 3 x 2-1/2 (80 x 65)3.50 x 2.87 (88,9 x 70,3)2.50 (63,5)1.7 (0,8)——2.50 (63,5)1.7 (0,8) 3 x 76mm (80 x 65)3.50 x 3.00 (88,9 x 76,1)2.50 (63,5)2.0 (0,9)——2.50 (63,5)2.0 (0,9) 4 x 1 (100 x 25)4.50 x 1.31 (114,3 x 33,4)——3.00 (76,2)2.9 (1,1)—— 4 x 1-1/4 (100 x 32)4.50 x 1.66 (114,3 x 42,4)——3.00 (76,2)2.2 (1,0)—— 4 x 1-1/2 (100 x 40)4.50 x 1.90 (114,3 x 48,3)——3.00 (76,2)2.3 (1,0)—— 4 x 2 (100 x 50)4.50 x 2.37 (114,3 x 60,3)3.00 (76,2)2.4 (1,1)——3.00 (76,2)2.4 (1,1) 4 x 2-1/2 (100 x 65)4.50 x 2.87 (114,3 x 73,0)3.00 (76,2)2.7 (1,2)——3.00 (76,2)2.7 (1,2) E to E E to E E to E FIGURE 550(1) CAST CONCENTRIC REDUCER FIGURE 350 FABRICATED CONCENTRIC REDUCER FIGURE 250 CAST CONCENTRIC REDUCER FIGURE 1 (1 OF 3) FIGURES 250, 350, AND 550 CONCENTRIC REDUCERS NOMINAL DIMENSIONS TFP1815 Page 3 of 26 1. Figure 550 is available for the America market only. Nominal Pipe Size Figure 250 Cast Figure 350 Fabricated Figure 550(1) Cast ANSI Inches (DN) O.D. Inches (mm) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 4 x 76mm (100 x 65)4.50 x 3.00 (114,3 x 76,1)3.00 (76,2)3.2 (1,5)——3.00 (76,2)3.2 (1,5) 4 x 3 (100 x 80)4.50 x 3.50 (114,3 x 88,9)3.00 (76,2)2.8 (1,3)——3.00 (76,2)2.8 (1,3) 139mm x 3 (125 x 80)5.50 x 3.50 (139,7 x 88,9)3.50 (88,9)4.2 (1,9)——3.50 (88,9)4.2 (1,9) 139mm x 4 (125 x 100)5.50 x 4.50 (139,7 x 114,3)3.50 (88,9)4.4 (2,0)——3.50 (88,9)4.4 (2,0) 5 x 2 (125 x 50)5.56 x 2.37 (141,3 x 60,3)——3.50 (88,9)4.6 (2,1)—— 5 x 2-1/2 (125 x 65)5.56 x 2.87 (141,3 x 73,0)——3.50 (88,9)4.5 (2,0)—— 5 x 3 (125 x 80)5.56 x 3.50 (141,3 x 88,9)3.50 (88,9)4.2 1,9)——3.50 (88,9)4.2 1,9) 5 x 4 (125 x 100)5.56 x 4.50 (141,3 x 114,3)3.50 (88,9)4.4 (2,0)——3.50 (88,9)4.4 (2,0) 165mm x 3 (150 x 80)6.50 x 3.50 (165,1 x 88,9)4.00 (101,6)5.5 (2,5)——4.00 (101,6)5.5 (2,5) 165mm x 4 (150 x 100)6.50 x 4.50 (165,1 x 114,3)4.00 (101,6)6.0. (2,7)——4.00 (101,6)6.0. (2,7) 165mm x 139mm (150 x 125)6.50 x 5.50 (165,1 x 139,7)4.00 (101,6)5.6 (2,5)——4.00 (101,6)5.6 (2,5) 6 x 1 (150 x 25)6.63 x 1.31 (168.3 x 33.7)4.00 (101,6)4.7 (2,1)——4.00 (101,6)4.7(2,1) 6 x 1-1/2 (150 x 40)6.63 x 1.90 (168.3 x 48.3)4.00 (101,6)5.0 (2,3)——4.00 (101,6)5.0 (2,3) 6 x 2 (150 x 50)6.63 x 2.37 (168,3 x 60,3)4.00 (101,6)5.3 (2,4)——4.00 (101,6)5.3 (2,4) 6 x 2-1/2 (150 x 65)6.63 x 2.87 (168,3 x 73,0)4.00 (101,6)5.7 (2,6)——4.00 (101,6)5.7 (2,6) 6 x 76mm (150 x 65)6.63 x 3.00 (168,3 x 76,1)4.00 (101,6)6.1 (2,7)——4.00 (101,6)6.1 (2,7) 6 x 3 (150 x 80)6.63 x 3.50 (168,3 x 88,9)4.00 (101,6)5.8 (2,6)——4.00 (101,6)5.8 (2,6) 6 x 108mm (150 x 100)6.63 x 4.25 (168,3 x 108,0)——4.00 (101,6)6.0 (2,7)—— 6 x 4 (150 x 100)6.63 x 4.50 (168,3 x 114,3)4.00 (101,6)6.0 (2,7)——4.00 (101,6)6.0 (2,7) 6 x 139mm (150 x 100)6.63 x 5.50 (168,3 x 139,7)4.00 (101,6)6.3 (2,3)——4.00 (101,6)6.3 (2,3) 6 x 5 (150 x 125)6.63 x 5.56 (168,3 x 141,3)4.00 (101,6)6.2 (2,8)——4.00 (101,6)6.2 (2,8) 216mm x 2-1/2 (200 x 65)8.52 x 2.87 (216,3 x 73,0)——5.00 (127,0)12.1 (5,5)—— 8 x 3 (200 x 80)8.63 x 3.50 (219,1 x 88,9)5.00 (127,0)11.5 (5,2)——5.00 (127,0)11.5 (5,2) 8 x 4 (200 x 100)8.63 x 4.50 (219,1 x 114,3)5.00 (127,0)10.7 (4,9)——5.00 (127,0)10.7 (4,9) E to E E to E E to E FIGURE 1 (2 OF 3) FIGURES 250, 350, AND 550 CONCENTRIC REDUCERS NOMINAL DIMENSIONS FIGURE 550 (1) CAST CONCENTRIC REDUCER FIGURE 350 FABRICATED CONCENTRIC REDUCER FIGURE 250 CAST CONCENTRIC REDUCER TFP1815 Page 4 of 26 1. Figure 550 is available for the America market only. Nominal Pipe Size Figure 250 Cast Figure 350 Fabricated Figure 550(1) Cast ANSI Inches (DN) O.D. Inches (mm) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 8 x 139mm (200 x 125)8.63 x 5.50 (219,1 x 139.7)5.00 (127,0)10.0 (4,5)——5.00 (127,0)10.0 (4,5) 8 x 5 (200 x 125)8.63 x 5.56 (219,1 x 141,3)5.00 (127,0)10.8 (4,9)——5.00 (127,0)10.8 (4,9) 8 x 165mm (200 x 150)8.63 x 6.50 (219,1 x 165.1)5.00 (127,0)11.0 (5,0)——5.00 (127,0)11.0 (5,0) 8 x 6 (200 x 150)8.63 x 6.63 (219,1 x 168,3)5.00 (127,0)11.3 (5,1)——5.00 (127,0)11.3 (5,1) 10 x 4 (250 x 100)10.75 x 4.50 (273,0 x 114,3)——6.00 (152,4)20.5 (9,3)—— 10 x 5 (250 x 125)10.75 x 5.56 (273,0 x 141,3)——6.00 (152,4)20.1 (9,1)—— 10 x 165mm (250 x 150)10.75 x 6.50 (273,0 x 165,1)6.00 (152,4)17.8 (8,0)——6.00 (152,4)17.8 (8,0) 10 x 6 (250 x 150)10.75 x 6.63 (273,0 x 168,3)6.00 (152,4)16.3 (7,4)——6.00 (152,4)16.3 (7,4) 10 x 8 (250 x 200)10.75 x 8.63 (273,0 x 219,1)6.00 (152,4)18.3 (8,3)——6.00 (152,4)18.3 (8,3) 12 x 4 (300 x 100)12.75 x 4.50 (323,9 x 114,3)7.00 (177,8)22.7 (10,3)——7.00 (177,8)22.7 (10,3) 12 x 6 (300 x 150)12.75 x 6.63 (323,9 x 168,3)7.00 (177,8)23.6 (10,7)——7.00 (177,8)24.2 (11,0) 12 x 8 (300 x 200)12.75 x 8.63 (323,9 x 219,1)7.00 (177,8)25.2 (11,4)——7.00 (177,8)25.8 (11,7) 12 x 10 (300 x 250)12.75 x 10.75 (323,9 x 273,0)7.00 (177,8)28.2 (12,8)7.00 (177,8)28.2 (12,8)7.00 (177,8)28.2 (12,8) E to E E to E E to E FIGURE 550 (1) CAST CONCENTRIC REDUCER FIGURE 350 FABRICATED CONCENTRIC REDUCER FIGURE 250 CAST CONCENTRIC REDUCER FIGURE 1 (3 OF 3) FIGURES 250, 350, AND 550 CONCENTRIC REDUCERS NOMINAL DIMENSIONS TFP1815 Page 5 of 26 Nominal Pipe Size Figure 501 Cast 45° Elbow Figure 510 Cast 90° Elbow ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 1(25)1.0(33,7)1.7(43,2)0.6(0,3)2.25(57,2)0.8(0,4) 1-1/4(32)1.7(42,4)1.8(44,5)0.8(0,4)2.8(69,9)1.1(0,5) 1-1/2(40)1.9(48,3)1.8(44,5)1.0(0,5)2.8(69,9)1.4(0,6) 2(50)2.4(60,3)2.0(50,8)1.3(0,6)3.3(82,6)2.0(0,9) 2-1/2(65)2.9(73,0)2.3(57,2)2.1(1,0)3.8(95,3)2.8(1,3) 76,1mm(65)3.0(76,1)2.3(57,2)2.2(1,0)3.8(95,3)3.0(1,3) 3(80)3.5(88,9)2.5(63,5)3.4(1,5)4.3(108,0)4.1(1,9) 4(100)4.5(114,3)3.0(76,2)5.5(2,5)5.0(127,0)7.0(3,2) 139,1mm(125)5.5(139,7)3.3(82,6)7.2(3,3)5.5(139,7)10.3(4,7) 165,1mm(150)6.5(165,1)3.5(88,9)9.2(4,2)6.5(165,1)13.9(6,3) 6(150)6.6(168,3)3.5(88,9)11.2(5,1)6.5(165,1)15.2(6,9) 8(200)8.6(219,1)4.5(108,0)20.6(9,3)7.8(196,9)29.6(13,4) 10(250)10.750(273,0)4.75(120,7)30.1(13,7)9.00(228,6)52.0(23,6) 12(300)12.750(323,9)5.25(133,4)48.0(22,0)10.00(254,0)66.4(30,1) C to E C to E FIGURE 2 FIGURES 501 AND 510 ELBOWS NOMINAL DIMENSIONS FIGURE 501 CAST 45° ELBOW FIGURE 510 CAST 90° ELBOW TFP1815 Page 6 of 26 Nominal Pipe Size Figure 519 Cast Tee Figure 260(1) Cast End Cap ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 1(25)1.3(33,4)2.25(57,2)1.1(0,5)0.8(21,1)0.2(0,1) 1-1/4(32)1.7(42,4)2.8(69,9)1.7(0,8)0.8(21,1)0.3(0,1) 1-1/2(40)1.9(48,3)2.8(69,9)2.1(1,00)0.8(21,1)0.4(0,2) 2(50)2.4(60,3)3.3(82,6)2.8(1,3)0.9(23,4)0.7(0,3) 2-1/2(65)2.9(73,0)3.8(95,3)4.4(2,0)0.9(23,4)1.0(0,5) 76,1mm(65)3.0(76,1)3.8(95,3)4.5(2,0)0.9(21,8)1.3(0,6) 3(80)3.5(88,9)4.3(108,0)6.5(3,0)0.9(23,4)1.4(0,6) 4(100)4.5(114,3)5.0(127,0)9.5(4,3)1.0(25,4)2.6(1,2) 139,1mm(125)5.5(139,7)5.5(139,7)13.9(6,3)0.9(23,4)4.7(2,1) 5(125)5.6(141,3)5.0(127,0)14.2 (6,4)1.0(25,4)5.0(2,3) 165,1mm(150)6.5(165,1)6.5(165,1)19.7(8,9)0.9(23,4)6.4(2,9) 6(150)6.6(168,3)6.5(165,1)22.4(10,2)1.0(25,4)6.2(2,8) 8(200)8.6(219,1)7.8(196,9)39.8(18,1)1.1(27,0)7.1(3,2) 10(250)10.8(273,0)9.00(228,6)64.2(29,1)1.0(25,8)24.5(11,1) 12(300)12.8(323,9)10.00(254,0)110.0(49,9)1.0(25,8)31.0(14,1) 1. Available with tapped plugs. Contact Tyco Fire Protection Products. C to E C to E E to E FIGURE 3 FIGURES 519 TEE AND FIGURE 260 END CAP NOMINAL DIMENSIONS FIGURE 519 CAST TEE FIGURE 260(1) CAST END CAP TFP1815 Page 7 of 26 Nominal Pipe Size Figure 510S 90° Elbow Figure 519S Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 2(50)2.4(60,3)2.8(69,9)1.5(0,7)2.8(69,9)2.6(1,2) 2-1/2(65)2.9(73,0)3.0(76,2)2.1(1,0)3.0(76,2)4.4(2,0) 76,1mm(65)3.0(76,1)3.0(76,2)2.3(1,0)3.0(76,2)3.1(1,4) 3(80)3.5(88,9)3.4(85,9)3.0(1,4)3.8(85,9)6.5(3,0) 4(100)4.5(114,3)4.0(101,6)5.0(2,3)4.0(101,6)10.7(4,9) 139mm(125)5.5(139,7)4.9(124,0)8.7(3,9)4.9(124,0)10.9(5,0) 5(125)5.6(141,3)4.8 (123,0)9.4 (4,3)4.8 (123,0)11.6 (5,3) 165,1mm(150)6.5(165,1)5.5(139,7)11.4(5,2)5.5(139,7)14.8(6,7) 6(150)6.6(168,3)5.5(139,7)12.1(5,5)5.5(139,7)15.0(6,8) 8(200)8.6(219,1)6.9(174,8)22.2(10,1)6.9(174,8)39.8(18,1) C to E C to E C to E FIGURE 4 FIGURES 510S ELBOW AND FIGURE 519S TEE NOMINAL DIMENSIONS FIGURE 510S 90° ELBOW SHORT PATTERN FIGURE 519S TEE SHORT PATTERN TFP1815 Page 8 of 26 Nominal Pipe Size Figure 510DE(1) 90° Drain Elbow ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Nominal A Inches (mm) Nominal B Inches (mm) Approx. Weight Lbs. (kg) 2(50)2.4(60,3)3.8(95,3)2.0(50,8)2.8(69,9)3.1 (1,4) 2-1/2(65)2.9(73,0)3.8(95,3)2.0(50,8)2.8(69,9)2.2 (1,0) 3(80)3.5(88,9)4.3(108,0)2.3(59,4)2.8(69,9)6.0(2,7) 4(100)4.5(114,3)5.0(127,0)2.9(72,4)2.8(69,9)8.6 (3,9) 6(150)6.6(168,3)6.5(165,1)3.9(99,6)2.8(69,9)18.0(8,2) 8(200)8.6(219,1)7.8(196,9)5.00(125,7)2.8(69,9)31.0(14,1) 1. Figure 510DE not available for the EMEA market. Nominal Pipe Size Dimensions- Inches (mm)Approx. Weight Lbs. (kg)ANSI Inches (DN) Outlet NPT(1) A O.D. B Takeout C D 1-1/2(40) 1/2 1.9(48,3) 1.3(31,8)1.8(44,5)1.9(48,0)0.8(0,4) 3/4 1.3(31,8)1.8(44,5)1.9(48,0)0.8(0,4) 1 1.4(34,8)2.0(50,8)2.0(51,3)0.9(0,4) 2(50) 1/2 2.4(60,3) 1.3(31,8)1.8(44,5)1.9(48,0)0.9(0,4) 3/4 1.3(31,8)1.8(44,5)1.9(48,0)0.8(0,4) 1 1.4(34,8)2.0(50,8)2.0(51,3)1.1(0,5) 2-1/2(65) 1/2 2.9(73,0) 1.5(37,3)2.0(50,0)1.9(48,0)1.8(0,8) 3/4 1.5(37,3)2.0(50,0)1.9(48,0)1.1(0,5) 1 1.4(34,8)2.0(50,8)2.0(51,3)1.1(0,5) 1. ISO threaded outlets are available upon request.2. ADACAP not available for the EMEA market.3. Rated pressure 300 psi (20,7 bar) C to E A B 1" NPT B D A CNPT FIGURE 5 FIGURE 510DE 90° DRAIN ELBOW NOMINAL DIMENSIONS FIGURE 6 ADACAP NOMINAL DIMENSIONS TFP1815 Page 9 of 26 Nominal Pipe Size Figure 320 Fabricated Thread Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to GE Inches (mm) Nominal C to TE Inches (mm) Approx.Weight Lbs. (kg) 1(25)1.31 (33,4)2.25 (57,2)2.25 (57,2)1.3 (0,6) 1-1/4(32)1.66 (42,4)2.75 (69,9)2.75 (69,9)1.5 (0,7) 1-1/2(40)1.90 (48,3)2.75 (69,9)2.75 (69,9)1.9 (0,9) 2(50)2.37 (60,3)3.25 (82,6)4.25 (108,0)3.2 (1,5) 2-1/2(65)2.87 (73,0)3.75 (95,3)3.75 (95,3)4.0 (1,8) 76mm(65)3.00 (76,1)3.75 (95,3)3.75 (95,3)4.5 (2,0) 3(80)3.50 (88,9)4.25 (108,0)6.00 (152,4)6.0 (2,7) 4(100)4.50 (114,3)5.00 (127,0)7.25 (184,2)11.0 (5,0) 139mm(125)5.50 (139,7)5.50 (139,7)5.50 (139,7)21.0 (9,5) 5(125)5.56 (141,3)5.50 (139,7)5.50 (139,7)23.0 (10,5) 165mm(150)6.50 (165,1)6.50 (165,1)6.50 (165,1)25 (11,3) 6(150)6.63 (168,3)6.50 (165,1)6.50 (165,1)28.0 (12,7) 8(200)8.63 (219,1)7.75 (196,9)7.75 (196,9)38.7 (17,6) 10(250)10.75 (273,0)9.00 (228,6)9.00 (228,6)72.1 (32,8) 12(300)12.75 (323,9)10.00 (254,0)10.00 (254,0)92.5 (42,0) 1. Figure 320 not available for the EMEA market. C to GE C to TE FIGURE 7 FIGURE 320 FABRICATED GROOVE X GROOVE X MALE THREAD TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 10 of 26 Nominal Pipe Size Figure 221 Cast Reducing Tee Figure 321 Fabricated Reducing Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 1-1/4 x 1-1/4 x 1 (32 x 32 x 25)1.66 x 1.66 x 1.31 (42,4 x 42,4 x 33,4)——2.75 (69,9)1.3 (0,6) 1-1/2 x 1-1/2 x 1 (40 x 40 x 25)1.90 x 1.90 x 1.31 (48,3 x 48,3 x 33,4)——2.75 (69,9)1.4 (0,6) 1-1/2 x 1-1/2 x 1-1/4 (40 x 40 x 32)1.90 x 1.90 x 1.66 (48,3 x 48,3 x 42,4)——2.75 (69,9)1.5 (0,7) 2 x 2 x 1 (50 x 50 x 25)2.37 x 2.37 x 1.32 (60,3 x 60,3 x 33,4)——3.25 (82,6)1.6 (0,7) 2 x 2 x 1-1/2 (50 x 50 x 40)2.37 x 2.37 x 1.90 (60,3 x 60,3 x 48,3)3.25 (82,6)2.7 (1,2)3.25 (82,6)2.0 (0,9) 2-1/2 x 2-1/2 x 1 (65 x 65 x 25)2.87 x 2.87 x 1.32 (73,0 x 73,0 x 33,4)——3.75 (95,3)2.3 (1,1) 2-1/2 x 2-1/2 x 1-1/4 (65 x 65 x 32)2.87 x 2.87 x 1.66 (73,0 x 73,0 x 42,4)——3.75 (95,3)4.2 (1,9) 2-1/2 x 2-1/2 x 1-1/2 (65 x 65 x 40)2.87 x 2.87 x 1.90 (73,0 x 73,0 x 48,3)——3.75 (95,3)4.2 (1,9) 2-1/2 x 2-1/2 x 2 (65 x 65 x 50)2.87 x 2.87 x 2.37 (73,0 x 73,0 x 60,3)3.75 (95,3)4.2 (1,9)3.75 (95,3)4.5 (2,0) 76mm x 76mm x 1 (65 x 65 x 25)3.00 x 3.00 x 1.32 (76,1 x 76,1 x 33,4)——3.75 (95,3)2.4 (1,1) 76mm x 76mm x 1-1/4 (65 x 65 x 32)3.00 x 3.00 x 1.66 (76,1 x 76,1 x 42,4)——3.75 (95,3)4.3 (2,0) 76mm x 76mm x 1-1/2 (65 x 65 x 40)3.00 x 3.00 x 1.90 (76,1 x 76,1 x 48,3)3.75 (95,3)4.5 (2,0)3.75 (95,3)4.2 (1,9) 76mm x 76mm x 2 (65 x 65 x 50)3.00 x 3.00 x 2.37 (76,1 x 76,1 x 60,3)3.75 (95,3)4.3 (2,0)3.75 (95,3)4.6 (2,1) 3 x 3 x 1 (80 x 80 x 25 3.50 x 3.50 x 1.32 (88,9 x 88,9 x 33,4)4.25 (108,0)5.6 (2,5)4.25 (108,0)6.0 (2,7) 3 x 3 x 1-1/4 (80 x 80 x 32)3.50 x 3.50 x 1.66 (88,9 x 88,9 x 42,4)——4.25 (108,0)6.1 (2,8) 3 x 3 x 1-1/2 (80 x 80 x 40)3.50 x 3.50 x 1.90 (88,9 x 88,9 x 48,3)4.25 (108,0)5.9 (2,7)4.25 (108,0)6.2 (2,8) 3 x 3 x 2 (80 x 80 x 50)3.50 x 3.50 x 2.37 (88,9 x 88,9 x 60,3)4.25 (108,0)6.0 (2,7)4.25 (108,0)6.4 (2,9) 3 x 3 x 2-1/2 (80 x 80 x 65)3.50 x 3.50 x 2.87 (88,9 x 88,9 x 73,0)4.25 (108,0)6.2 (2,8)4.25 (108,0)6.5 (2,9) 3 x 3 x 76mm (80 x 80 x 65)3.50 x 3.50 x 3.00 (88,9 x 88,9 x 76,1)4.25 (108,0)6.0 (2,7)4.25 (108,0)6.7 (3,0) 4 x 4 x 1 (100 x 100 x 25)4.50 x 4.50 x 1.32 (114,3 x 114,3 x 33,4)——5.00 (127,0)8.0 (3,7) 4 x 4 x 1-1/4 (100 x 100 x 32)4.50 x 4.50 x 1.66 (114,3 x 114,3 x 42,4)——5.00 (127,0)9.8 (4,4) 4 x 4 x 1-1/2 (100 x 100 x 40)4.50 x 4.50 x 1.90 (114,3 x 114,3 x 48,3)——5.00 (127,0)9.9 (4,5) 4 x 4 x 2 (100 x 100 x 50)4.50 x 4.50 x 2.37 (114,3 x 114,3 x 60,3)5.00 (127,0)9.1 (4,1)5.00 (127,0)11.0 (5,0) 4 x 4 x 2-1/2 (100 x 100 x 65)4.50 x 4.50 x 2.88 (114,3 x 114,3 x 73,0)5.00 (127,0)9.5 (4,3)5.00 (127,0)11.2 (5,1) 4 x 4 x 76mm (125 x 125 x 65)4.50 x 4.50 x 3.00 (114,3 x 114,3 x 76,1)5.00 (127,0)9.5 (4,3)5.00 (127,0 11.4 (5,2) C to E C to E C to E C to E FIGURE 8 (1 OF 3) FIGURES 221 AND 321 REDUCING TEES NOMINAL DIMENSIONS FIGURE 221 CAST TEE REDUCING GROOVED (SEGMENT WELDED) FIGURE 321 FABRICATED TEE REDUCING GROOVED (SEGMENT WELDED) TFP1815 Page 11 of 26 Nominal Pipe Size Figure 221 Cast Reducing Tee Figure 321 Fabricated Reducing Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 4 x 4 x 3 (100 x 100 x 80)4.50 x 4.50 x 3.50 (114,3 x 114,3 x 88,9)5.00 (127,0)9.7 (4,4)5.00 (127,0 11.6 (5,3) 139,7mm x 139,7mm x 3 (125 x 125 x 80)5.50 x 5.50 x 3.50 (139,7 x 139,7 x 88,9)5.50 (139,7)12.7 (5,8)5.50 (139,7)12.2 (5,5) 139,7mm x 139,7mm x 4 (125 x 125 x 100)5.50 x 5.50 x 4.50 (139,7 x 139,7 x 114,3)5.50 (139,7)13.4 (6,1)5.50 (139,7)12.5 (5,7) 5 x 5 x 1 (125 x 125 x 25)5.56 x 5.56 x 1.31 (141,3 x 141,3 x 33,4)——5.50 (139,7)13.0 (5,9) 5 x 5 x 1-1/2 (125 x 125 x 40)5.56 x 5.56 x 1.90 (141,3 x 141,3 x 48,3)——5.50 (139,7)13.4 (6,1) 5 x 5 x 2 (125 x 125 x 50)5.56 x 5.56 x 2.37 (141,3 x 141,3 x 60,3)——5.50 (139,7)14.1 (6,4) 5 x 5 x 2-1/2 (125 x 125 x 65)5.56 x 5.56 x 2.87 (141,3 x 141,3 x 73,0)5.50 (139,7)18.0 (8,2)5.50 (139,7)14.8 (6,7) 5 x 5 x 76mm (125 x 125 x 65)5.56 x 5.56 x 3.00 (141,3 x 141,3 x 76,1)——5.50 (139,7)15.3 (6,9) 5 x 5 x 3 (125 x 125 x 80)5.56 x 5.56 x 3.50 (141,3 x 141,3 x 88,9)5.50 (139,7)14.0 (6,4)5.50 (139,7)16.0 (7,3) 5 x 5 x 4 (125 x 125 x 100)5.56 x 5.56 x 4.50 (141,3 x 141,3 x 114,3)5.50 (139,7)13.9 (6,3)5.50 (139,7)16.4 (7,4) 165mm x 165mm x 3 (150 x 150 x 80)6.50 x 6.50 x 3.50 (165,1 x 165,1 x 88,9)6.50 (165,1)18.0 8,2 6.50 (165,1)22.0 (10,0) 165mm x 165mm x 4 (150 x 150 x 100)6.50 x 6.50 x 4.50 (165,1 x 165,1 x 114,3)6.50 (165,1)19.5 8,9 6.50 (165,1)22.6 (10,3) 165mm x 165mm x 5 (150 x 150 x 125)6.50 x 6.50 x 5.50 (165,1 x 165,1 x 139,7)——6.50 (165,1)23.2 (10,5) 165mm x 165mm x 139mm (150 x 150 x 125)6.50 x 6.50 x 5.50 (165,1 x 165,1 x 141,3)——6.50 (165,1)22.9 (10,4) 6 x 6 x 1 (150 x 150 x 25)6.63 x 6.63 x 1.31 (168,3 x 168,3 x 33,4)——6.50 (165,1)22.8 (10,3) 6 x 6 x 1-1/2 (150 x 150 x 40)6.63 x 6.63 x 1.90 (168,3 x 168,3 x 48,3)——6.50 (165,1)22.9 (10,4) 6 x 6 x 2 (150 x 150 x 50)6.63 x 6.63 x 2.37 (168,3 x 168,3 x 60,3)6.50 (165,1)19.4 (8,8)6.50 (165,1)23.0 (10,4) 6 x 6 x 2-1/2 (150 x 150 x 65)6.63 x 6.63 x 2.87 (168,3 x 168,3 x 73,0)6.50 (165,1)21.2 (9,8)6.50 (165,1)23.4 (10,6) 6 x 6 x 76mm (150 x 150 x 65)6.63 x 6.63 x 3.00 (168,3 x 168,3 x 76,1)6.50 (165,1)21.2 9,8 6.50 (165,1)23.5 (10,7) 6 x 6 x 3 (150 x 150 x 80)6.63 x 6.63 x 3.50 (168,3 x 168,3 x 88,9)6.50 (165,1)21.0 (9,5)6.50 (165,1)23.7 (10,7) 6 x 6 x 4 (150 x 150 x 100)6.63 x 6.63 x 4.50 (168,3 x 168,3 x 114,3)6.50 (165,1)21.8 (9,9)6.50 (165,1)23.9 (10,8) 6 x 6 x 139mm (150 x 150 x 125)6.63 x 6.63 x 5.50 (168,3 x 168,3 x 139,7)6.50 (165,1)23.0 10,4 6.50 (165,1)24.0 (10,9) 6 x 6 x 5 (150 x 150 x 125)6.63 x 6.63 x 5.56 (168,3 x 168,3 x 141,3)——6.50 (165,1)27.0 12,2 8 x 8 x 1-1/2 (200 x 200 x 40)8.63 x 8.63 x 1.90 (219,1 x 219,1 x 48,3)——7.75 (196,9 36.0 (16,3) 8 x 8 x 2 (200 x 200 x 50)8.63 x 8.63 x 2.375 (219,1 x 219,1 x 60,3)——7.75 (196,9)36.2 (16,4) C to E C to E C to E C to E FIGURE 8 (2 OF 3) FIGURES 221 AND 321 REDUCING TEES NOMINAL DIMENSIONS FIGURE 221 CAST TEE REDUCING GROOVED (SEGMENT WELDED) FIGURE 321 FABRICATED TEE REDUCING GROOVED (SEGMENT WELDED) TFP1815 Page 12 of 26 Nominal Pipe Size Figure 221 Cast Reducing Tee Figure 321 Fabricated Reducing Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 8 x 8 x 2-1/2 (200 x 200 x 65)8.63 x 8.63 x 2.88 (219,1 x 219,1 x 73,0)——7.75 (196,9)36.4 (16,5) 216mm x 216mm x 165mm (200 x 200 x 150)8.52 x 8.52 x 6.50 (216,3 x 216,3 x 165,1)——7.75 (196,9)37.9 (17,2) 8 x 8 x 76mm (200 x 200 x 65)8.63 x 8.63 x 3.00 (216,1 x 219,1 x 76.1)——7.75 (196,9)36.4 (16,5) 8 x 8 x 3 (200 x 200 x 80)8.63 x 8.63 x 3.50 (219,1 x 219,1 x 88,9)——7.75 (196,9)36.5 (16,6) 8 x 8 x 4 (200 x 200 x 100)8.63 x 8.63 x 4.50 (219,1 x 219,1 x 114,1)7.75 (196,9)37.2 (16,9)7.75 (196,9)36.4 (16,5) 8 x 8 x 139mm (200 x 200 x 125)8.63 x 8.63 x 5.56 (219,1 x 219,1 x 139,7)7.75 (196,9)37.7 (17,1)7.75 (196,9)36.7 (16,6) 8 x 8 x 5 (200 x 200 x 125)8.63 x 8.63 x 5.50 (219,1 x 219,1 x 141,3)——7.75 (196,9)36.8 (16,7) 8 x 8 x 165mm (200 x 200 x 150)8.63 x 8.63 x 6.50 (219,1 x 219,1 x 165,1)7.75 (196,9)37.7 (17,1)7.75 (196,9)39.0 (17,7) 10 x 10 x 1-1/2 (250 x 250 x 40)10.75 x 10.75 x 1.90 (273,0 x 273,0 x 48,3)——9.00 (228,6)57.0 (25,8) 10 x 10 x 2 (250 x 250 x 50)10.75 x 10.75 x 2.37 (273,0 x 273,0 x 60,3)——9.00 (228,6)57.1 (25,9) 10 x 10 x 2-1/2 (250 x 250 x 65)10.75 x 10.75 x 2.87 (273,0 x 273,0 x 73,0)——9.00 (228,6)57.3 (26,0) 10 x 10 x 3 (250 x 250 x 80)10.75 x 10.75 x 3.50 (273,0 x 273,0 x 88,9)——9.00 (228,6)57.4 (26,0) 10 x 10 x 4 (250 x 250 x 100)10.75 x 10.75 x 4.50 (273,0 x 273,0 x 114,3)——9.00 (228,6)57.8 (26,2) 10 x 10 x 5 (250 x 250 x 125)10.75 x 10.75 x 5.56 (273,0 x 273,0 x 141,3)——9.00 (228,6)58.0 (26,3) 10 x 10 x 6 (250 x 250 x 150)10.75 x 10.75 x 6.63 (273,0 x 273,0 x 168,3)——9.00 (228,6)62.0 (28,1) 10 x 10 x 8 (250 x 250 x 200)10.75 x 10.75 x 8.63 (273,0 x 273,0 x 219,1)——9.00 (228,6)63.0 (28,6) 12 x 12 x 1 (300 x 300 x 25)12.75 x 12.75 x 1.31 (323,9 x 323,9 x 33,4)——10.00 (254,0)64.0 (29,0) 12 x 12 x 2 (300 x 300 x 50)12.75 x 12.75 x 2.37 (323,9 x 323,9 x 60,3)——10.00 (254,0)69.5 (31,5) 12 x 12 x 2-1/2 (300 x 300 x 65)12.75 x 12.75 x 2.87 (323,9 x 323,9 x 73,0)——10.00 (254,0)75.6 (34,3) 12 x 12 x 3 (300 x 300 x 80)12.75 x 12.75 x 3.50 (323,9 x 323,9 x 88,9)——10.00 (254,0)80.2 (36,4) 12 x 12 x 4 (300 x 300 x 100)12.75 x 12.75 x 4.50 (323,9 x 323,9 x 114,3)——10.00 (254,0)80.5 (36,5) 12 x 12 x 5 (300 x 300 x 125)12.75 x 12.75 x 5.56 (323,9 x 323,9 x 141,3)——10.00 (254,0)80.7 (36,6) 12 x 12 x 6 (300 x 300 x 150)12.75 x 12.75 x 6.63 (323,9 x 323,9 x 168,3)——10.00 (254,0)80.9 (36,7) 12 x 12 x 165mm (300 x 300 x 150)12.75 x 12.75 x 6.50 (323,9 x 323,9 x 165,1)——10.00 (254,0)79.9 (36,2) 12 x 12 x 8 (300 x 300 x 200)12.75 x 12.75 x 8.63 (323,9 x 323,9 x 219,1)——10.00 (254,0)76.3 (34,6) 12 x 12 x 10 (300 x 300 x 250)12.75 x 12.75 x 10.75 (323,9 x 323,9 x 273,0)——10.00 (254,0)77.6 (35,2) C to E C to E C to E C to E FIGURE 8 (3 OF 3) FIGURES 221 AND 321 REDUCING TEES NOMINAL DIMENSIONS FIGURE 221 CAST TEE REDUCING GROOVED (SEGMENT WELDED) FIGURE 321 FABRICATED TEE REDUCING GROOVED (SEGMENT WELDED) TFP1815 Page 13 of 26 Nominal Pipe Size Figure 327(1)Figure 341(1)Figure 342(1) ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Mating Flange Bolt Qty. Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Mating Flange Bolt Qty. Approx. Weight Lbs. (kg) 1 (25)1.31 (33,4)2.25 (57,2)2.2 (1,0)3.00 (76,2)4 2.3 (1,0)3.00 (76,2)4 4.0 (1,8) 1-1/4 (32)1.66 (42,4)2.75 (69,9)2.2 (1,0)4.00 (101,6)4 2.8 (1,3)4.00 (101,6)4 4.6 (2,1) 1-1/2 (40)1.90 (48,3)2.75 (69,9)2.5 (1,1)4.00 (101,6)4 3.2 (1,5)4.00 (101,6)4 7.1 (3,2) 2 (50)2.37 (60,3)3.25 (82,6)3.7 (1,7)4.00 (101,6)4 5.2 (2,4)4.00 (101,6)8 8.2 (3,7) 2-1/2 (65)2.87 (73,0)3.75 (95,3)5.8 (2,6)4.00 (101,6)4 8.0 (3,6)4.00 (101,6)8 11.9 (5,4) 76mm (65)3.00 (76,1)3.75 (95,3)6.0 (2,7)4.00 (101,6)4 8.8 (4,0)4.00 (101,6)8 12.5 (5,7) 3 (80)3.50 (88,9)4.25 (108,0)8.6 (3,9)4.00 (101,6)4 10.2 (4,6)4.00 (101,6)8 15.5 (7,0) 4 (100)4.50 (114,3)5.00 (127,0)20.7 (9,4)6.00 (152,4)8 17.2 (7,8)6.00 (152,4)8 28.0 (12,7) 139mm (125)5.50 (139,7)5.50 (139,7)18.3 (8,3)6.00 (152,4)8 18.5 (8,4)6.00 (152,4)8 32.5 (14,7) 5 (125)5.56 (141,3)5.50 (139,7)18.5 (8,4)6.00 (152,4)8 21.4 (9,7)6.00 (152,4)8 37.0 (16,8) 165mm (150)6.50 (165,1)6.50 (165,1)26.2 (11,9)6.00 (152,4)8 22.0 (10,0)6.00 (152,4)12 42.5 (19,3) 6 (150)6.63 (168,3)6.50 (165,1)27.3 (12,4)6.00 (152,4)8 26.0 (11,8)6.00 (152,4)12 48.0 (21,8) 216mm (200)8.52 (216,3)7.75 (196,9)44.0 (20,0)6.00 (152,4)8 34.5 (15,6)6.00 (152,4)12 72.5 (32,9) 8 (200)8.63 (219,1)7.75 (196,9)48.0 (21,7)6.00 (152,4)8 38.4 (17,4)6.00 (152,4)12 79.0 (35,8) 10 (250)10.75 (273,0)9.00 (228,6)75.0 (34,0)8.00 (203,2)12 65.0 (29,5)8.00 (203,2)16 122.0 (55,3) 12 (300)12.75 (323,9)10.00 (254,0)95.8 (43,4)8.00 (203,2)12 91.0 (41,3)8.00 (203,2)16 183.0 (83,0) 1. Figure 327, Figure 341, and Figure 342 are not available for the EMEA market. C to E C to E E to E FIGURE 9 FIGURE 327 CROSS AND FIGURE 341 AND FIGURE 342 FLANGE ADAPTERS NOMINAL DIMENSIONS FIGURE 341(1) FABRICATED FLANGE ADAPTER ANSI CLASS 150 LBS. GROOVED FIGURE 342(1) FABRICATED FLANGE ADAPTER ANSI CLASS 300 LBS. GROOVED FIGURE 327(1) FABRICATED CROSS GROOVED (SEGMENT WELDED) TFP1815 Page 14 of 26 1. Figure 323 not available for the EMEA market. Nominal Pipe Size Nominal C to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) O.D. Inches (mm) 2 x 2 x 3/4 (50 x 50 x 20)2.37 x 2.37 x 1.05 (60,3 x 60,3 x 26,7)3.25 (82,6)2.0 (0,9) 2 x 2 x 1 (50 x 50 x 25)2.37 x 2.37 x 1.31 (60,3 x 60,3 x 33,4)3.25 (82,6)2.2 (1,0) 2 x 2 x 1-1/4 (50 x 50 x 32)2.37 x 2.37 x 1.66 (60,3 x 60,3 x 42,4)3.25 (82,6)2.3 (1,0) 2 x 2 x 1-1/2 (50 x 50 x 40)2.37 x 2.37 x 1.90 (60,3 x 60,3 x 48,3)3.25 (82,6)1.4 (1,1) 2-1/2 x 2-1/2 x 1 (65 x 65 x 25)2.875 x 2.875 x 1.315 (73,0 x 73,0 x 33,4)3.75 (95,3)3.6 (1,6) 2-1/2 x 2-1/2 x 1-1/4 (65 x 65 x 32)2.875 x 2.875 x 1.660 (73,0 x 73,0 x 42,4)3.75 (95,3)3.8 (1,7) 2-1/2 x 2-1/2 x 1-1/2 (65 x 65 x 40)2.875 x 2.875 x 1.900 (73,0 x 73,0 x 48,3)3.75 (95,3)4.0 (1,8) 2-1/2 x 2-1/2 x 2 (65 x 65 x 50)2.875 x 2.875 x 2.375 (73,0 x 73,0 x 60,3)3.75 (95,3)4.2 (1,9) 76mm x 76mm x 1 (65 x 65 x 25)3.00 x 3.00 x 1.31 (76,1 x 76,1 x 33,4)3.75 (95,3)3.8 (1,7) 76mm x 76mm x 1-1/4 (65 x 65 x 32)3.00 x 3.00 x 1.66 (76,1 x 76,1 x 42,4)3.75 (95,3)4.0 (1,8) 76mm x 76mm x 1-1/2 (65 x 65 x 40)3.00 x 3.00 x 1.90 (76,1 x 76,1 x 48,3)3.75 (95,3)4.2 (1,9) 3 x 3 x 3/4 (80 x 80 x 20)3.50 x 3.50 x 1.05 (88,9 x 88,9 x 26,7)4.25 (108,0)5.2 (2,4) 3 x 3 x 1 (80 x 80 x 25)3.50 x 3.50 x 1.31 (88,9 x 88,9 x 33,4)4.25 (108,0)5.7 (2,6) 3 x 3 x 1-1/2 (80 x 80 x 40)3.50 x 3.50 x 1.90 (88,9 x 88,9 x 48,3)4.25 (108,0)5.8 (2,6) 3 x 3 x 2 (80 x 80 x 50)3.50 x 3.50 x 2.37 (88,9 x 88,9 x 60,3)4.25 (108,0)5.9 (2,7) 3 x 3 x 2-1/2 (80 x 80 x 65)3.50 x 3.50 x 2.87 (88,9 x 88,9 x 73,0)4.25 (108,0)6.3 (2,9) 3 x 3 x 76mm (80 x 80 x 65)3.50 x 3.50 x 3.00 (88,9 x 88,9 x 76,1)4.25 (108,0)6.5 (2,9) 4 x 4 x 3/4 (100 x 100 x 20)4.50 x 4.50 x 1.05 (114,3 x 114,3 x 26,7)3.75 (95,3)6.4 (2,9) 4 x 4 x 1 (100 x 100 x 25)4.50 x 4.50 x 1.31 (114,3 x 114,3 x 33,4)5.00 (127,0)6.9 (3,1) 4 x 4 x 1-1/4 (100 x 100 x 32)4.50 x 4.50 x 1.66 (114,3 x 114,3 x 42,4)5.00 (127,0)7.6 (3,4) 4 x 4 x 1-1/2 (100 x 100 x 40)4.50 x 4.50 x 1.90 (114,3 x 114,3 x 48,3)5.00 (127,0)8.3 (3,8) 4 x 4 x 2 (100 x 100 x 50)4.50 x 4.50 x 2.37 (114,3 x 114,3 x 60,3)5.00 (127,0)9.6 (4,4) 4 x 4 x 2-1/2 (100 x 100 x 65)4.500 x 4.500 x 2.875 (114,3 x 114,3 x 73,0)5.00 (127,0)10.0 (4,5) 4 x 4 x 76mm (100 x 100 x 65)4.500 x 4.500 x 3.00 (114,3 x 114,3 x 76,1)5.00 (127,0)10.5 (4,8) C to E C to E FIGURE 10 (1 OF 3) FIGURE 323 FABRICATED GROOVE X GROOVE X MALE THREAD REDUCING TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 15 of 26 1. Figure 323 not available for the EMEA market. Nominal Pipe Size Nominal C to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) O.D. Inches (mm) 4 x 4 x 3 (100 x 100 x 80)4.50 x 4.50 x 3.50 (114,3 x 114,3 x 88,9)5.00 (127,0)10.3 (4,7) 5 x 5 x 2 (125 x 125 x 50)5.56 x 5.56 x 2.37 (141,3 x 141,3 x 60,3)5.50 (139,7)14.0 (6,4) 5 x 5 x 2-1/2 (125 x 125 x 65)5.56 x 5.56 x 2.87 (141,3 x 141,3 x 73,0)5.50 (139,7)14.3 (6,5) 5 x 5 x 76mm (125 x 125 x 65)5.56 x 5.56 x 3.00 (141,3 x 141,3 x 76,1)5.50 (139,7)14.5 (6,6) 5 x 5 x 3 (125 x 125 x 80)5.56 x 5.56 x 3.50 (141,3 x 141,3 x 88,9)5.50 (139,7)14.6 (6,6) 5 x 5 x 4 (125 x 125 x 100)5.56 x 5.56 x 4.50 (141,3 x 141,3 x 114,3)5.50 (139,7)15.1 (6,8) 165mm x 165mm x 2 (150 x 150 x 50)6.50 x 6.50 x 2.37 (165,1 x 165,1 x 60,3)6.50 (165,1)9.5 (4,3) 165mm x 165mm x 2-1/2 (150 x 150 x 65)6.50 x 6.50 x 2.875 (165,1 x 165,1 x 73,0)6.50 (165,1)9.7 (4,4) 165mm x 165mm x 76mm (150 x 150 x 65)6.50 x 6.50 x 3.00 (165,1 x 165,1 x 76,1)6.50 (165,1)9.7 (4,4) 165mm x 165mm x 3 (150 x 150 x 80)6.50 x 6.50 x 3.50 (165,1 x 165,1 x 88,9)6.50 (165,1)9.8 (4,4) 165mm x 165mm x 4 (150 x 150 x 100)6.50 x 6.50 x 4.50 (165,1 x 165,1 x 114,3)6.50 (165,1)10.0 (4,5) 165mm x 165mm x 5 (150 x 150 x 125)6.50 x 6.50 x 5.563 (165,1 x 165,1 x 141,3)6.50 (165,1)10.2 (4,6) 6 x 6 x 1-1/2 (150 x 150 x 40)6.625 x 6.625 x 1.90 (168,3 x 168,3 x 48,3)6.50 (165,1)19.0 (8,6) 6 x 6 x 2 (150 x 150 x 50)6.625 x 6.625 x 2.375 (168,3 x 168,3 x 60,3)6.50 (165,1)21.3 (9,7) 6 x 6 x 2-1/2 (150 x 150 x 65)6.625 x 6.625 x 2.875 (168,3 x 168,3 x 73,0)6.50 (165,1)21.7 (9,8) 6 x 6 x 76mm (150 x 150 x 65)6.625 x 6.625 x 3.00 (168,3 x 168,3 x 76,1)6.50 (165,1)14.5 (6,6) 6 x 6 x 3 (150 x 150 x 80)6.625 x 6.625 x 3.500 (168,3 x 168,3 x 88,9)6.50 (165,1)22.0 (10,0) 6 x 6 x 4 (150 x 150 x 100)6.625 x 6.625 x 4.500 (168,3 x 168,3 x 114,3)6.50 (165,1)22.5 (10.2) 6 x 6 x 5 (150 x 150 x 125)6.625 x 6.625 x 5.563 (168,3 x 168,3 x 141,3)6.50 (165,1)23.1 10,5 8 x 8 x 2 (200 x 200 x 50)8.63 x 8.63 x 2.37 (219,1 x 219,1 x 60,3)7.75 (196,9)32.7 (14,8) 8 x 8 x 3 (200 x 200 x 80)8.63 x 8.63 x 3.50 (219,1 x 219,1 x 88,9)7.75 (196,9)33.5 (15,2) 8 x 8 x 4 (200 x 200 x 100)8.63 x 8.63 x 4.50 (219,1 x 219,1 x 114,1)7.75 (196,9)34.5 (15,6) 8 x 8 x 5 (200 x 200 x 125)8.63 x 8.63 x 5.56 (219,1 x 219,1 x 141,3)7.75 (196,9)34.7 (15,7) 8 x 8 x 165mm (200 x 200 x 150)8.63 x 8.63 x 6.50 (219,1 x 219,1 x 165,1)7.75 (196,9)35.0 (15,9) C to E C to E FIGURE 10 (2 OF 3) FIGURE 323 FABRICATED GROOVE X GROOVE X MALE THREAD REDUCING TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 16 of 26 1. Figure 323 not available for the EMEA market. Nominal Pipe Size Nominal C to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) O.D. Inches (mm) 8 x 8 x 6 (200 x 200 x 150)8.63 x 8.63 x 6.63 (219,1 x 219,1 x 168,3)7.75 (196,9)35.6 (16,1) 10 x 10 x 2 (250 x 250 x 50)10.75 x 10.75 x 2.37 (273,0 x 273,0 x 60,3)9.00 (228,6)52.2 (23,7) 10 x 10 x 3 (250 x 250 x 80)10.75 x 10.75 x 3.50 (273,0 x 273,0 x 88,9)9.00 (228,6)53.0 (24,0) 10 x 10 x 4 (250 x 250 x 100)10.75 x 10.75 x 4.50 (273,0 x 273,0 x 114,3)9.00 (228,6)53.6 (24,3) 10 x 10 x 5 (250 x 250 x 125)10.75 x 10.75 x 5.56 (273,0 x 273,0 x 141,3)9.00 (228,6)54.2 (24,6) 10 x 10 x 165mm (250 x 250 x 150)10.75 x 10.75 x 6.50 (273,0 x 273,0 x 165,1)9.00 (228,6)55.5 (25,2) 10 x 10 x 6 (250 x 250 x 150)10.75 x 10.75 x 6.63 (273,0 x 273,0 x 168,3)9.00 (228,6)54.9 (24,9) 10 x 10 x 8 (250 x 250 x 200)10.75 x 10.75 x 8.63 (273,0 x 273,0 x 219,1)9.00 (228,6)55.3 (25,1) 12 x 12 x 3 (300 x 300 x 80)12.75 x 12.75 x 3.50 (323,9 x 323,9 x 88,9)10.00 (254,0)74.6 (33,8) 12 x 12 x 4 (300 x 300 x 100)12.75 x 12.75 x 4.50 (323,9 x 323,9 x 141,3)10.00 (254,0)75.1 (34,1) 12 x 12 x 5 (300 x 300 x 125)12.75 x 12.75 x 5.563 (323,9 x 323,9 x 114,3)10.00 (254,0)75.6 (34,3) 12 x 12 x 165mm (300 x 300 x 150)12.75 x 12.75 x 6.50 (323,9 x 323,9 x 165,1)10.00 (254,0)76.2 (34,6) 12 x 12 x 6 (300 x 300 x 150)12.75 x 12.75 x 6.625 (323,9 x 323,9 x 168,3)10.00 (254,0)76.2 (34,6) 12 x 12 x 8 (300 x 300 x 200)12.750 x 12.750 x 8.625 (323,9 x 323,9 x 219,1)10.00 (254,0)76.3 (34,6) 12 x 12 x 10 (300 x 300 x 250)12.750 x 12.750 x 10.750 (323,9 x 323,9 x 273,0)10.00 (254,0)77.6 (35,2) C to E C to E FIGURE 10 (3 OF 3) FIGURE 323 FABRICATED GROOVE X GROOVE X MALE THREAD REDUCING TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 17 of 26 1. Figure 372 not available for the EMEA market. Nominal Pipe Size E to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) Pipe O.D. Inches (mm) 1-1/2 x 1 (40 x 25)1.90 x 1.31 (48,3 x 33,7)2.50 (63,5)0.6 (0,3) 2 x 3/4 (50 x 20)2.37 x 1.05 (60,3 x 26,7)2.50 (63,5)1.0 (0,5) 2 x 1 (50 x 25)2.37 x 1.31 (60,3 x 33,4)2.50 (63,5)0.8 (0,4) 2 x 1-1/4 (50 x 32)2.37 x 1.66 (60,3 x 42,4)2.50 (63,5)0.8 (0,4) 2 x 1-1/2 (50 x 40)2.37 x 1.90 (60,3 x 48,3)2.50 (63,5)0.8 (0,4) 2-1/2 x 1 (65 x 25)2.87 x 1.31 (73,0 x 33,4)2.50 (63,5)0.9 (0,4) 2-1/2 x 1-1/4 (65 x 32)2.87 x 1.66 (73,0 x 42,4)2.50 (63,5)1.0 (0,5) 2-1/2 x 1-1/2 (65 x 40)2.87 x 1.90 (73,0 x 48,3)2.50 (63,5)1.3 (0,6) 2-1/2 x 2 (65 x 50)2.87 x 2.37 (73,0 x 60,3)2.50 (63,5)1.2 (0,5) 76mm x 1-1/4 (65 x 32)3.00 x 1.66 (76,1 x 42,4)2.50 (63,5)1.0 (0,5) 76mm x 1-1/2 (65 x 40)3.00 x 1.90 (76,1 x 48,3)2.50 (63,5)1.1 (0,5) 76mm x 2 (65 x 50)3.00 x 2.37 (76,1 x 60,3)2.50 (63,5)1.2 (0,5) 3 x 3/4 (80 x 20)3.50 x 1.05 (88,9 x 26,7)2.50 (63,5)1.1 (0,5) 3 x 1 (80 x 25)3.50 x 1.31 (88,9 x 33,4)2.50 (63,5)1.3 (0,6) 3 x 1-1/4 (80 x 32)3.50 x 1.66 (88,9 x 42,4)2.5 (63,5)1.3 (0,6) 3 x 1-1/2 (80 x 40)3.50 x 1.90 (88,9 x 48,3)2.50 (63.5)1.3 (0,6) 3 x 2 (80 x 50)3.50 x 2.37 (88,9 x 60,3)2.50 (63.5)1.3 (0,6) 3 x 2-1/2 (80 x 65)3.50 x 2.87 (88,9 x 73,0)2.50 (63.5)1.5 (0,7) 3 x 76mm (80 x 65)3.50 x 3.00 (88,9 x 76,1)2.50 (63.5)1.5 (0,7) 4 x 1 (100 x 25)4.50 x 1.31 (114,3 x 33,4)3.00 (76,2)1.8 (0,8) 4 x 1-1/4 (100 x 32)4.50 x 1.66 (114,3 x 42,4)3.00 (76,2)2.0 (0,9) 4 x 1-1/2 (100 x 40)4.50 x 1.90 (114,3 x 48,3)3.00 (76,2)2.3 (1,0) 4 x 2 (100 x 50)4.50 x 2.37 (114,3 x 60,3)3.00 (76,2)2.3 (1,0) 4 x 2-1/2 (100 x 65)4.50 x 2.87 (114,3 x 73,0)3.00 (76,2)2.3 (1,0) E to E FIGURE 11 (1 OF 2) FIGURE 372 FABRICATED CONCENTRIC REDUCER GROOVE X MALE THREAD (MPT) NOMINAL DIMENSIONS TFP1815 Page 18 of 26 1. Figure 372 not available for the EMEA market. Nominal Pipe Size E to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) Pipe O.D. Inches (mm) 4 x 3 (100 x 80)4.50 x 3.50 (114,3 x 88,9)3.00 (76,2)2.6 (1,2) 5 x 4 (125 x 100)5.56 x 4.50 (141,3 x 114,3)3.50 (88,9)4.5 (2,0) 165mm x 1 (150 x 25)6.50 x 1.31 (165,1 x 33,4)4.00 (101,6)1.2 (0,5) 165mm x 2 (150 x 50)6.50 x 2.37 (165,1 x 60,3)4.00 (101,6)5.5 (2,5) 165mm x 76mm (150 x 65)6.50 x 3.00 (165,1 x 76,1)4.00 (101,6)5.7 (2,6) 165mm x 3 (150 x 50)6.50 x 3.50 (165,1 x 88,9)4.00 (101,6)5.8 (2,6) 165mm x 4 (150 x 50)6.50 x 4.50 (165,1 x 114,3)4.00 (101,6)5.8 (2,6) 165mm x 5 (150 x 50)6.50 x 5.563 (165,1 x 141,3)4.00 (101,6)5.8 (2,6) 6 x 1 (150 x 25)6.63 x 1.31 (168,3 x 33,4)4.00 (101,6)5.2 (2,4) 6 x 2 (150 x 50)6.63 x 2.37 (168,3 x 60,3)4.00 (101,6)5.4 (2,4) 6 x 2-1/2 (150 x 65)6.63 x 2.87 (168,3 x 73,0)4.00 (101,6)5.6 (2,5) 6 x 76mm (150 x 65)6.63 x 3.00 (168,3 x 76,1)4.00 (101,6)5.8 (2,6) 6 x 3 (150 x 80)6.63 x 3.50 (168,3 x 88,9)4.00 (101,6)6.0 (2,7) 6 x 4 (150 x 100)6.63 x 4.50 (168,3 x 114,3)4.00 (101,6)6.2 (2,8) 6 x 5 (150 x 125)6.63 x 5.56 (168,3 x 141,3)4.00 (101,6)6.7 (3,0) E to E FIGURE 11 (2 OF 2) FIGURE 372 FABRICATED CONCENTRIC REDUCER GROOVE X MALE THREAD (MPT) NOMINAL DIMENSIONS TFP1815 Page 19 of 26 Nominal Pipe Size Figures 211, 311, & 511 Figures 212, 312, & 512 ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 1-1/4(32)1.660(42,4)1.38 (35,1)0.4 (0,2)1.75 (44,5)0.4 (0,2) 1-1/2(40)1.900(48,3)1.38 (35,1)0.5 (0,2)1.75 (44,5)0.5 (0,2) 2(50)2.375(60,3)1.38 (35,1)0.6 (0,3)1.88 (47,8)0.6 (0,3) 2-1/2(65)2.875(73,0)1.50 (38,1)1.1 (0,5)2.00 (50,8)0.7 (0.3) 76,1mm(65)3.000(76,1)1.50 (38,1)1.1 (0,5)2.00 (50,8)1.2 (0,5) 3(80)3.500(88,9)1.50 (38,1)1.2(0,5)2.25 (57,2)1.4 (0,6) 4(100)4.500(114,3)1.75 (44,5)2.2 (1,0)2.63 (66,8)2.4 (1,1) 139,7mm(125)5.500(139,7)2.00 (50,8)2.3 (1,0)2.88 (73,2)2.5 (1,1) 5(125)5.563(141,3)2.00 (50,8)3.3 (1,5)2.88 (73,2)4.1 (1,9) 165,1mm(150)6.500(165,1)2.00 (50.8)3.5 (1,6)3.13 (79,5)4.3 (2,0) 6(150)6.625(168,3)2.00 (50.8)4.6 (2,1)3.13 (79,5)5.6 (2,5) 8(200)8.625(219,1)2.00 (50,8)8.7 (3,9)3.88 (98,6)11.1 (5,0) 10(250)10.750(273,0)2.13 (54,1)9.1 (4,1)4.38 (111,3)14.0 (6,4) 12(300)12.750(323,9)2.25 (57,2)16.7 (7,6)4.88 (124,0)22.0 (10,0) C to E C to E FIGURE 12 FIGURES 211, 311, AND 511 FABRICATED ELBOWS AND FIGURES 212, 312, AND 512 FABRICATED ELBOWS NOMINAL DIMENSIONS FIGURES 212, 312, & 512 FABRICATED 22½° ELBOW (SEGMENT WELDED) FIGURES 211, 311, & 511 FABRICATED 11¼° ELBOW (SEGMENT WELDED) TFP1815 Page 20 of 26 Nominal Pipe Size Figures 391, 392 & 393(1) ANSI Inches (DN)O.D. Inches (mm) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 1-1/4(32)1.660(42,4)4.00 (101,6)0.8 (0,4) 1-1/2(40)1.900(48,3)4.00 (101,6)0.9 (0,4) 2(50)2.375(60,3)4.00 (101,6)1.2 (0,5) 2-1/2(65)2.875(73,0)4.00 (101,6)1.9 (0,9) 76,1mm(65)3.000(76,1)4.00 (101,6)1.9 (0,9) 3(80)3.500(88,9)4.00 (101,6)2.5 (1,1) 4(100)4.500(114,3)6.00 (154,4)5.5 (2,5) 139,7mm(125)5.500(139,7)6.00 (154,4)5.6 (2,5) 5(125)5.563(141,3)6.00 (154,4)7.4 (3,4) 165,1mm(150)6.500(165,1)6.00 (154,4)7.6 (3,4) 6(150)6.625(168,3)6.00 (154,4)9.5 (4,3) 8(200)8.625(219,1)6.00 (154,4)14.2 (6,4) 10(250)10.750(273,0)8.00 (203,2)27.0 (12,2) 12(300)12.750(323,9)8.00 (203,2)33.0 (15,0) 1. Figure 391, Figure 392, and Figure 393 are not available for the EMEA market. E to E E to E E to E FIGURE 391(1) FABRICATED ADAPTER NIPPLE GROOVE X MALE THREAD (MA) FIGURE 392(1) FABRICATED ADAPTER NIPPLE GROOVE X GROOVE FIGURE 393(1) FABRICATED ADAPTER NIPPLE GROOVE X PLAIN FIGURE 13 FIGURES 391, 392, AND 393 FABRICATED ADAPTER NIPPLES NOMINAL DIMENSIONS TFP1815 Page 21 of 26 FIGURE 15 FIGURE 328 FABRICATED STANDPIPE TEE NOMINAL DIMENSIONS ANSI Inches (DN) O.D. Inches (mm) Nominal C to GE Inches (mm) Nominal C to TE Inches (mm) Approx. Weight Lbs. (kg) 4 x 4 x 2-1/2 (100 X 100 X 65)5.563 x 5.563 x 8.625 (141,3 x 141,3 x 219,1)13.313 (388,14)9.313 (236,55)8.7 (3,9) 6 x 6 x 2-1/2 (150 X 50 X 65)6.625 x 6.625 x 8.625 (168,3 x 168,3 x 219,1)13.313 (388,14)8-3/4 (222,25)13.7 (6,2) 1. Figure 328 not available for the EMEA and APAC market. ANSI Inches (DN) O.D. Inches (mm) Nominal C to GE Inches (mm) Nominal C to TE Inches (mm) Approx. Weight Lbs. (kg 5 x 5 x 8 (125 X 125 X 200)5.563 x 5.563 x 8.625 (141,3 x 141,3 x 219,1)13.313 (388,14)9.313 (236,55)27.8 (12,6) 6 x 6 x 8 (150 X 150 X 200)6.625 x 6.625 x 8.625 (168,3 x 168,3 x 219,1)13.313 (388,14)8-3/4 (222,25)36.7 (16,4) 1. Figure 507/50L not available for the EMEA market. C to GE C to TE C to TE C to GE FIGURE 14 FIGURE 507/50L FABRICATED BULLHEAD TEE NOMINAL DIMENSIONS PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3201 90˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A A FIGURE 3201 - 90° ELBOW Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 11⁄4 500 1.75 0.90 32 3450 44.45 0.41 11⁄2 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 3450 57.15 0.84 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3202 45˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A AFIGURE 3202 - 45° ELBOW Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.12 0.46 25 3450 28.44 0.21 11⁄4 500 1.29 0.73 32 3450 32.76 0.33 11⁄2 500 1.43 0.92 40 3450 36.32 0.42 2 500 1.68 1.50 50 3450 42.67 0.68 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.14 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3283 Bushings For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3283 - BUSHINGS Nominal Size Max. WorkingPressures Dimensions Style Approx. Wt. EachMale (M) x Female (F)A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 500 0.75 0.25 1.42 Outside 0.22 25 x 15 3450 19.05 6.35 36.06 0.10 1 x 3⁄4 500 0.75 0.25 1.42 Outside 0.17 25 x 20 3450 19.05 6.35 36.06 0.08 11⁄4 x 1 500 0.80 0.28 1.76 Outside 0.28 32 x 25 3450 20.32 7.11 44.70 0.13 11⁄2 x 1 500 0.83 0.31 2.00 Outside 0.45 40 x 25 3450 21.08 7.874 50.80 0.20 11⁄2 x 11⁄4 500 0.83 0.31 2.00 Outside 0.30 40 x 32 3450 21.08 7.874 50.80 0.14 2 x 1 500 0.88 0.41 1.95 Inside 0.67 50 x 25 3450 22.35 10.414 49.53 0.30 2 x 11⁄4 500 0.88 0.34 2.48 Outside 0.73 50 x 32 3450 22.35 8.636 62.99 0.33 2 x 11⁄2 500 0.88 0.34 2.48 Outside 0.61 50 x 40 3450 22.35 8.636 62.99 0.28 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. A B C A B C Inside Head Outside Head A B C A B C Inside Head Outside Head M F M F A B C A B C Inside Head Outside Head A B C A B C Inside Head Outside Head M F M F PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3224 Cap For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3224 - CAP Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 11⁄4 500 1.28 0.43 32 3450 32.51 0.20 11⁄2 500 1.33 0.60 40 3450 33.78 0.27 2 500 1.45 0.91 50 3450 36.83 0.41 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3221 Coupling For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3221 - COUPLING Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.67 0.40 25 3450 42.42 0.18 11⁄4 500 1.93 0.57 32 3450 49.02 0.26 11⁄2 500 2.15 0.75 40 3450 54.61 0.34 2 500 2.53 1.15 50 3450 64.26 0.52 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3201R Reducing 90˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3201R - REDUCING 90° ELBOW Nominal Size Max. Working Pressures Dimensions Approx. Wt. Each1 x 2 A B In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.20 1 x 3⁄4 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 11⁄4 x 1⁄2 500 1.34 1.53 0.64 32 x 15 34550 34.03 38.86 0.29 11⁄4 x 3⁄4 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11⁄4 x 1 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11⁄2 x 1 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 11⁄2 x 11⁄4 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x 1⁄2 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 3⁄4 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11⁄4 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11⁄2 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. A B 2 1 1 x 2 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3221R Reducing Coupling For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3221R - REDUCING COUPLING Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 x 1⁄2 500 1.69 0.39 25 x 15 3450 42.92 0.18 1 x 3⁄4 500 1.69 0.53 25 x 20 3450 42.92 0.24 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3205R Reducing Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 x 1 500 1.50 1.36 1.50 0.6425 x 15 x 25 3450 38.10 34.54 38.10 0.29 1 x 3⁄4 x 1 500 1.50 1.45 1.50 0.73 25 x 20 x 25 3450 38.10 36.83 38.10 0.33 1 x 1 x 1⁄2 500 1.26 1.26 1.36 0.71 25 x 25 x 15 3450 32.00 32.00 34.54 0.32 1 x 1 x 3⁄4 500 1.37 1.37 1.45 0.76 25 x 25 x 20 3450 34.80 34.80 36.83 0.34 1 x 1 x 11⁄4* 500 1.67 1.67 1.58 0.98 25 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 11⁄2* 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 11⁄4 x 1 x 1⁄2* 500 1.34 1.26 1.53 0.82 32 x 25 x 15 3450 34.04 32.00 38.86 0.37 11⁄4 x 1 x 3⁄4 500 1.45 1.37 1.62 0.90 32 x 25 x 20 3450 36.83 34.80 41.15 0.41 11⁄4 x 1 x 1 500 1.58 1.50 1.67 1.0032 x 25 x 25 3450 40.13 38.10 42.42 0.45 11⁄4 x 1 x 11⁄4 500 1.75 1.67 1.75 1.08 32 x 25 x 32 3450 44.45 42.42 44.45 0.49 11⁄4 x 1 x 11⁄2 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 11⁄4 x 11⁄4 x 1⁄2 500 1.34 1.34 1.53 0.86 32 x 32 x 15 3450 34.04 34.04 38.86 0.39 FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11⁄4 x 11⁄4 x 3⁄4 500 1.45 1.45 1.62 0.92 32 x 32 x 20 3450 36.83 36.83 41.15 0.42 11⁄4 x 11⁄4 x 1 500 1.58 1.58 1.67 0.9532 x 32 x 25 3450 40.13 40.13 42.42 0.43 11⁄4 x 11⁄4 x 11⁄2* 500 1.88 1.88 1.82 1.4532 x 32 x 40 3450 47.75 47.75 46.22 0.66 C A B 3 1 1 x 2 x 3 2 s Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3205R Reducing Tee FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs. (kg) 11⁄2 x 11⁄2 x 2*500 2.16 2.16 2.02 1.98 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 2 x 1 x 2 500 2.25 2.02 2.25 2.15 50 x 25 x 50 3450 57.15 51.31 57.15 0.98 2 x 11⁄4 x 2 500 2.25 2.10 2.25 2.30 50 x 32 x 50 3450 57.15 53.34 57.15 1.04 2 x 11⁄2 x 1⁄2 500 1.49 1.41 1.88 1.50 50 x 40 x 15 3450 37.85 35.81 47.75 0.68 2 x 11⁄2 x 3⁄4 500 1.60 1.52 1.97 1.62 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 2 x 11⁄2 x 1 500 1.73 1.65 2.02 1.64 50 x 40 x 25 3450 43.94 41.91 51.31 0.74 2 x 11⁄2 x 11⁄4 500 1.90 1.82 2.10 1.80 50 x 40 x 32 3450 48.26 46.23 53.34 0.82 2 x 11⁄2 x 11⁄2 500 2.02 1.94 2.16 2.00 50 x 40 x 40 3450 51.31 49.28 54.86 0.91 2 x 11⁄2 x 2 500 2.25 2.16 2.25 2.35 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 2 x 2 x 1⁄2 500 1.49 1.49 1.88 1.60 50 x 50 x 15 3450 37.85 37.85 47.75 0.73 2 x 2 x 3⁄4 500 1.60 1.60 1.97 1.68 50 x 50 x 20 3450 40.64 40.64 50.04 0.76 2 x 2 x 1 500 1.73 1.73 2.02 1.85 50 x 50 x 25 3450 43.94 43.94 51.31 0.84 2 x 2 x 11⁄4 500 1.90 1.90 2.10 2.04 50 x 50 x 32 3450 44.45 42.42 44.45 0.93 2 x 2 x 11⁄2 500 2.02 2.02 2.16 2.18 50 x 50 x 40 3450 44.45 42.42 44.45 0.99 FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs. (kg) 11⁄4 x 11⁄4 x 2*500 2.10 2.10 1.90 1.75 32 x 32 x 50 3450 53.34 53.34 48.26 0.79 11⁄2 x 1 x 1⁄2 500 1.41 1.34 1.66 0.95 40 x 25 x 15 3450 35.81 34.04 42.16 0.43 11⁄2 x 1 x 3⁄4 500 1.52 1.37 1.75 1.14 40 x 25 x 20 3450 38.61 34.80 44.45 0.52 11⁄2 x 1 x 1 500 1.65 1.50 1.80 1.17 40 x 25 x 25 3450 41.91 38.10 45.72 0.53 11⁄2 x 1 x 11⁄4 500 1.82 1.67 1.88 1.34 40 x 25 x 32 3450 46.23 42.42 47.75 0.61 11⁄2 x 1 x 11⁄2 500 1.94 1.80 1.94 1.45 40 x 25 x 40 3450 49.28 45.72 49.28 0.66 11⁄2 x11⁄4 x 1⁄2 500 1.41 1.34 1.66 1.05 40 x 32 x 15 3450 35.81 34.04 42.16 0.48 11⁄2 x11⁄4 x 3⁄4 500 1.52 1.45 1.75 1.15 40 x 32 x 20 3450 38.61 36.83 44.45 0.5 11⁄2 x 11⁄4 x 1 500 1.65 1.58 1.80 1.25 40 x 32 x 25 3450 41.91 40.13 45.72 0.57 11⁄2 x 11⁄4 x 2*500 2.16 2.10 2.02 1.90 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 11⁄2 x 11⁄2 x 1⁄2 500 1.41 1.41 1.16 1.15 40 x 40 x 15 3450 35.81 35.81 29.46 0.52 11⁄2 x 11⁄2 x 3⁄4 500 1.52 1.52 1.75 1.24 40 x 40 x 20 3450 38.61 38.61 44.45 0.56 11⁄2 x 11⁄2 x 1 500 1.65 1.65 1.80 1.30 40 x 40 x 25 3450 41.91 41.91 45.72 0.59 11⁄2 x 11⁄2 x 11⁄4 500 1.82 1.82 1.88 1.48 40 x 40 x 32 3450 46.23 46.23 47.75 0.67 C A B 3 1 1 x 2 x 3 2 s Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3205 Straight Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A AA FIGURE 3205 - STRAIGHT TEE Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.50 0.85 25 3450 38.10 0.39 11⁄4 500 1.75 1.22 32 3450 44.45 0.55 11⁄2 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 3450 57.15 1.11 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-5.16 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.14 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS s Pressure - Temperature Ratings in accordance with ASME B16.3 Class 150 FIG. 3388 Cored Plug For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3388 - CORED PLUG Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1⁄2*500 0.94 0.10 15 3450 23.87 0.05 3⁄4 500 1.07 0.17 20 3450 27.17 0.08 1 500 1.25 0.28 25 3450 31.75 0.13 11⁄4 500 1.36 0.44 32 3450 34.54 0.20 11⁄2 500 1.45 0.62 40 3450 36.83 0.28 2 500 1.56 0.91 50 3450 39.62 0.41 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as Solid Plug. FGAPL-7 FlameGuard®, LabWaste™ and EverTUFF® CTS CPVC Installer Protection Plan Approved Products List Updated 07-28-2016 The following commercial products have been tested and evaluated by Spears® for acceptable use with FlameGuard® CPVC Fire Sprinkler Products: Firestop Sealants, Caulks & Sleeves • Boss® Products - BOSS® 816 Intumescent Firestop Sealant • Boss® Products - BOSS® FireMastic-HPE Firestop Sealant • Boss® Products - BOSS® FireMastic-300 Firestop Sealant • Boss® Products - BOSS® 333 Polyurethane Expanding Foam • Hilti - FS-One High Performance Intumescent Firestop Sealant • Hilti - FS-One Max High Performance Intumescent Firestop Sealant • Hilti - CP 606 Flexible Firestop Sealant • Hilti - CP 601S Elastomeric Firestop Sealant • Hilti - CP 506 Smoke and Acoustic Sealant • Hilti - CFS-S SIL GG Firestop Sealant • Specifi ed Technologies (STI) – SpecSeal® SSS Sealant • Specifi ed Technologies (STI) – SpecSeal® LCI Sealant • Specifi ed Technologies (STI) – BlazeStop™ WF300 Intumescent Firestop Caulk • Specifi ed Technologies (STI) – SpecSeal® LC Sealant • Specifi ed Technologies (STI) – SpecSeal® SIL Sealant • Specifi ed Technologies (STI) – SpecSeal® SIL S/L Sealant • Specifi ed Technologies (STI) – SpecSeal® SNS Sealant • Specifi ed Technologies (STI) – SpecSeal® AS Spray • Specifi ed Technologies (STI) – SpecSeal® SNS Spray • FPPI/Tremco® – Caulk & Walk Firestop Sealant • 3M™ Fire Barrier Water Tight Sealant 1003 SL • 3M™ Fire Barrier Water Tight Sealant 1000 NS • 3M™ Fire Barrier Water Tight Sealant 3000 WT • 3M™ Fire Barrier Sealant IC 15WB+ • 3M™ Ultra GS Wrap Strip GS-40 Firestop Wrap • RectorSeal® Metacaulk® 1000 Firestop Sealant • RectorSeal® Metacaulk® MC 150+ Firestop Sealant • RectorSeal® Metacaulk® 350i Firestop Sealant • Walraven BIS Pacifyre® MK II Fire Sleeve Insulation • Handi-Foam® Fireblock Sealant by Fomo Products, Inc. • Dow® – Great Stuff “Gaps & Cracks” Foam Sealant (non-professional version) • Dow Corning® 795 Silicone Building Sealant Fire Barriers • Flame Safe Fire Poly FPCC • Contego Fire Barrier Latex Primer Antifreeze • Follow NFPA Guidelines – DO NOT use Glycol antifreeze solutions. • J. C. Whitlam Frost-Proof GL48 NOTE: Not a Listed Antifreeze per NFPA Requirements, contact local AHJ for approval 1. 1 of 3 2. 3. 2 of 3 FlameGuard®, LabWaste™ and EverTUFF® CTS CPVC Installer Protection PlanApproved Products List Updated 07-28-2016 Anti MIC Coated Antimicrobial Metal Pipe NOTE: Factory applied coatings only, after market coatings are NOT covered. Antimicrobial Internally Coated Steel Pipe on Hybrid Systems FM Approvals is one of several nationally recognized testing laboratories in the United States and offers information on the compatibility of antimicrobial internally coated steel pipe. FM’s approval relates only to the acceptability of manufacturer’s applied anti-mic coatings to steel pipe. Click Here for FM Approvals (Requires Website Registration) Thread Sealants • Spears ® BLUE 75™ Thread Sealant • Generic: PTFE Tape Thread Sealant (3.5 mil minimum), or use Spears® Gasket Sealed SofTorque™ and TorqueSafe™ head adapters that require NO Tape or Paste. • FPPI ® PipeFit® Thread Sealant • J.C. Whitlam Blue Magic Industrial Thread Compound • J. C. Whitlam Talon PTFE Compound Zero V.O.C Thread Sealant • Permabond ® LH056 Thread Sealant - For metal threads only. Approved for use in combination with metal systems. • Mill-Rose Blue Monster™ Heavy-Duty Industrial Grade with PTFE • Mill-Rose Blue Monster™ Paste Thread Sealant • RectorSeal ® T Plus 2 Pipe Thread Sealant with PTFE • Oatey Great White Pipe Joint Compound with PTFE • LA-CO ® Leak-Tite® Blue • LA-CO ® Slick-Tite® Paste with PTFE Thread Anti-Seize • IMS High Heat Copper Flake Thread Lube and Anti-Seize #103783 Cutting Oils • Fire Protection Products, Inc. (FPPI ®) - ThreadFit® Clear Cutting Oil • Ridgid ® Company - Ridgid® NU Clear • Lube-Tech ® / Lubrication Technologies - Ace Transul-Kut 3200 • Walker industries - CL-Free Plus • Brecco Brecoil Gasket Lubricant • FPPI ® LubeFit Gasket Lubricant Foam Insulation • Nomaco ® Imcolock® Foam Insulation • Nomaco ® Nomalock® Foam Insulation • Hilti CF 810 CJ Insulating Foam • Hilti CF-AS CJP Insulating Foam Wood Protectant Coatings • Eco Building Products – Eco Red Shield™ • Anabec Systems newBUILD White • Anabec Systems newBUILD Clear 5. 4. 6. 7. 8. 9. 10. SPEARS® MANUFACTURING COMPANY CORPORATE OFFICE 15853 Olden St., Sylmar, CA 91342 • PO Box 9203, Sylmar, CA 91392 (818) 364-1611 • www.spearsmfg.com This Installer Protection Plan does NOT cover: • Pipe that has been allowed to freeze by homeowner or contractor. • “Acts of God”, i.e., tornadoes, earthquakes, landslides, etc. • Poor workmanship and installation errors. Spears® laboratory testing has shown these products to be compatible with satisfactory performance in normal installation of CPVC products. However, the potential for compatibility problems can be present in installations where CPVC materials are highly stressed. Such situations include, but are not limited to, inadequate compensation for thermal expansion and contraction, excessive bending beyond specifi ed limits, improper pipe hanger or anchor selection or installation, over tightening of threaded joints, and other improper CPVC installation practices yielding high stress loads. Proper installation of each product in accordance with the manufacturer’s published Installation Instructions, Spears® FlameGuard® CPVC Fire Sprinkler Products Installation Instructions, EverTUFF® CTS CPVC Installation Instruction, and LabWaste™ CPVC Corrosisive Waste Drainage System Installation Instructions is essential. PLEASE NOTE: Not all products listed are suitable for all applications. Check product requirements. 3 of 3 FlameGuard®, LabWaste™ and EverTUFF® CTS CPVC Installer Protection PlanApproved Products List Updated 07-28-2016 Hangers/Supports* • Clic® (NOTE: Clic hangers are not approved for FlameGuard® applications) • Tolco • B-Line • PHD Manufacturing® *It is the installing contractor’s responsibility to ensure that the hangers & supports used are appropriate for the application and have any and all required listings and/or approvals Miscellaneous Ancillary Products • 3M™ Super 77™ Multipurpose Spray Adhesive • Hart/Cooley F114 Residential Series Flexible Air Ducts • Fiberlock AfterShock Fungicidal Coating • InCide Technologies “Board Defense” Insecticide, Termiticide and Fungicide. • FlexHead Flexible Drops (For FlameGuard only) • Erico Caddy Easy Snap Grommet (For both FlameGuard and CTS) • Kolbi Wrap Around Pipe Marker (For both FlameGuard and CTS) • Henkel OSI SC-175 Draft and Acoustical Sound Sealant • Atco Flexible Duct System • K-Flex® Isul-Tube® • Skyline 5S105 Strapping Tape 10. 11. FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 385 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com CPVC FIRE SPRINKLER PIPE SDR 13.5 (ASTM F 442) Part Number Nominal Size Average O.D. Average I.D.Approx. Weight Lbs./Ft. Inches (mm) Inches (mm) Inches (mm) CP-007 3/4 (19.1) 1.050 (26.7) .874 (22.5) 0.168 CP-010 1 (25.4)1.315 (33.4) 1.101 (28.2) 0.262 CP-012 1-1/4 (31.8) 1.660 (42.2) 1.394 (35.6) 0.418 CP-015 1-1/2 (38.1) 1.900 (48.3) 1.598 (40.7) 0.548 CP-020 2 (50.8) 2.375 (60.3) 2.003 (50.9) 0.859 CP-025 2-1/2 (63.5) 2.875 (73.0) 2.423 (61.5) 1.257 CP-030 3 (76.2) 3.500 (88.9) 2.950 (75.0) 1.867 Dimension Reference G = (LAYING LENGTH) Intersection of center lines to bottom of socket/thread; 90° elbows, tees, crosses; ± 1/32 inch. H = Intersection of center lines to face of fitting; 90° elbows tees, crosses; ± 1/32 inch. J = Intersection of center lines to bottom of socket/thread; 45° elbows; ± 1/32 inch L = Overall length of fittings; ± 1/16 inch. M = Outside diameter of socket/thread hub; ± 1/16 inch. N = Socket bottom to socket bottom; couplings; ± 1/16 inch. Q = Width of flats; ±1/16 inch. W = Height of cap; ± 1/16 inch. The information contained in this section is based on current information and Product design at the time of publication and is subject to change without notification. Our ongoing commitment to product improvement may result in some variation. No representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or results to be obtained therefrom. For verification of technical data or additional information not contained herein, please contact Spears® Technical Services Department [West Coast: (818) 364-1611—East Coast: (678) 985-1263]. General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED, INSTALLED and OPERATED in accordance with ESTABLISHED DESIGN AND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems. Suitability for the intended service application should be determined by the installer and/ or user prior to installation of a plastic piping system. All Installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems. PRIOR TO ASSEMBLY, all piping system components should be inspected for damage or irregularities. Mating components should be checked to assure that tolerances and engagements are compatible. Do not use any components that appear irregular or do not fit properly. Contact the appropriate manufacturer of the component product in question to determine usability. Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance with Spears® Manufacturing CompanyFlameGuard®CPVC Fire Sprinkler Piping Products Installation Instructions - FG-3 NOTE — Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spears® Regional Distribution Center. SOLVENT CEMENT CONNECTIONS — Spears® Manufacturing Company recommends the use of Spears® FS-5 One Step solvent cement for joining Spears® products. Use of solvent cementing products not approved for CPVC fire sprinkler systems, or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION — Spears® Manufacturing Company recommends the use of Spears®BLUE 75™ Thread Sealant. This product has been tested by Spears®and the sealant manufacturer for compatibility with the Spears® CPVC fire sprinkler products. Consult the sprinkler head manufacturer before using this product. WARNING: OTHER PIPE JOINT COMPOUNDS OR PASTES MAY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMPONENTS. Care must be taken to avoid over torquing - generally 1 to 2 turns beyond finger tight is all that is required to make up a threaded connection. Factory testing has indicated 10-25 ft. lbs. of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS — This type of connection can only be made with Spears® TorqueSafe™ style Gasket Sealed Female Sprinkler Adapters. DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER. Tape or paste may impair proper sealing and function. Testing has shown that hand tight until snug is all that is needed to seal this special connection. Installation Training Available - Contact Spears® Technical Services for Details FlameGuard® Products must be installed in accordance with Spears® CPVC Fire Sprinkler Piping Products Installation Instructions, National Fire Protection Association Standards 13, 13R, 13D, and in accordance with local codes. Code requirements and fi eld conditions may differ. It is the responsibility of the installing contractor to insure that the product is suitable to meet these requirements. “Lead Free” low lead certification – unless other wise specified, all Spears® FlameGuard® fittings specified here-in are certified by NSF International to ANSI/ NSF®Standard 61, Annex G and is in compliance with California’s Health & Safety Code Section 116825 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%. Spears® PVC and CPVC Pipe, Fittings and Valves have always been lead-free and Certified by NSF International for use in potable water systems. Spears® offers a wide range of lead-free specialty fittings and transition adapters for plumbing applications. However, certain brass threaded adapter fittings for applications that are not intended to convey water for human consumption through drinking or cooking are still produced and available. FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 386 TEE Socket x Socket x Socket Part Number Size G H L M Approx. Wt. (Lbs.) 4201-007 3/4 9/16 1-1/2 2-31/32 1-5/16 .11 4201-010 1 7/8 1-13/16 3-5/8 1-5/8 .20 4201-012 1-1/4 15/32 2-3/32 4-7/32 2 .29 4201-015 1-1/2 1-5/32 2-9/16 5-3/32 2-11/32 .54 4201-020 2 1-13/32 2-15/16 5-7/8 2-7/8 .86 4201-025 2-1/2 1-23/32 3-1/2 7 3-15/32 1.62 4201-030 3 2-1/16 3-31/32 7-15/16 4-5/32 2.53 G H L M SOCKET DIMENSIONS SCH 40 - ASTM F438 SCH 80 - ASTM F439 Size Socket Entrance A Socket Bottom B Tolerance SCH 40 Minimum Socket Length C SCH 80 Minimum Socket Length C 3/4 1.058 1.046 ± .004 .719 1.000 1 1.325 1.130 ± .005 .875 1.125 1-1/4 1.670 1.655 ± .005 .938 1.250 1-1/2 1.912 1.894 ± .006 1.094 1.375 2 2.387 2.369 ± .005 1.156 1.500 2-1/2 2.889 2.868 ± .007 1.750 1.750 3 3.516 3.492 ± .008 1.875 1.875 A C B REDUCING TEE Socket x Socket x Socket Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4201-102 3/4x3/4x1 3/4 3/4 3/4 1-11/16 1-25/32 1-11/16 3-13/32 1-5/16 1-21/32 1-5/16 .13 4201-125 1x3/4x3/4 23/32 7/8 23/32 1-25/32 1-13/16 1-21/32 3-7/16 1-19/32 1-11/32 1-5/16 .16 4201-126 1x3/4x1 23/32 23/32 3/4 1-27/32 1-27/32 1-3/4 3-19/32 1-5/8 1-5/8 1-5/16 .17 4201-131 1x1x3/4 11/16 13/16 11/16 1-13/16 1-13/16 1-13/16 3-5/8 1-5/8 1-5/16 1-5/8 .17 4201-157 1-1/4x1x3/4 11/16 1-1/32 11/16 1-15/16 2-1/32 1-13/16 3-25/32 2-3/32 1-13/32 1-23/32 .32 M H1 H H2 G G2 L G1M2 M1 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 387 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com TorqueSafe™ SPRINKLER HEAD TEE Gasket Sealed Brass Thread Insert Style Socket x Socket x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101 G 3/4x3/4x1/2 7/16 1-3/16 7/16 1-7/16 1-7/16 1-17/32 2-29/32 1-3/8 1-3/8 1-3/8 .22 4202-124 G 1x3/4x1/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130 G 1x1x1/2 7/16 1-11/32 7/16 1-9/16 1-11/16 1-9/16 3-1/8 1-23/32 1-3/8 1-23/32 .28 4202-166 G 1-1/4x1-1/4x1/2 7/16 1-5/8 7/16 1-11/16 1-15/16 1-11/16 3-3/8 2-1/16 1-3/8 2-1/16 .34 4202-209 G 1-1/2x1-1/2x1/2 1/2 1-13/16 1/2 1-7/8 2-3/32 1-7/8 3-3/4 2-11/32 1-3/8 2-11/32 .41 4202-247 G 2x2x1/2 1/2 2-1/16 1/2 2 2-11/32 2 4-1/32 2-27/32 1-3/8 2-27/32 .54 Not intended to convey or dispense water for human consumption through drinking or cooking H M G1 H1 M1 H2G2G M2 L CONTINUED REDUCING TEE Socket x Socket x Socket Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4201-158 1-1/4x1x1 27/32 29/32 25/32 2-1/16 2-1/32 1-29/32 3-15/16 1-31/32 1-5/8 1-5/8 .24 4201-159 1-1/4x1x1-1/4 31/32 31/32 31/32 2-7/32 2-7/32 2-3/32 4-11/32 2-1/8 2-1/8 1-23/32 .36 4201-167 1-1/4x1-1/4x3/4 21/32 1 21/32 1-29/32 2 1-29/32 3-13/16 2 1-5/16 2 .22 4201-168 1-1/4x1-1/4x1 13/16 1 13/16 2-1/16 2-1/8 2-1/16 4-1/8 1-31/32 1-21/32 1-31/32 .24 4201-169 1-1/4x1-1/4x1-1/2 1-1/8 15/16 1-1/8 2-3/8 2-11/32 2-3/8 4-3/4 2-3/32 2-11/32 2-3/32 .51 4201-201 1-1/2x1-1/4x3/4 11/16 1 1/4 2-1/16 2 1-15/16 4 2-5/16 1-3/8 2-1/16 .41 4201-202 1-1/2x1-1/4x1 27/32 1-1/32 1 2-7/32 2-5/32 2-1/4 4-15/32 2-5/16 1-11/16 2-1/16 .42 4201-210 1-1/2x1-1/2x3/4 11/16 1-1/32 11/16 2-1/16 2-1/32 2-1/16 4-5/32 2-11/32 1-13/32 2-11/32 .39 4201-211 1-1/2x1-1/2x1 13/16 1-3/32 13/16 2-3/16 2-1/4 2-3/16 4-3/8 2-11/32 1-3/4 2-11/32 .41 4201-212 1-1/2x1-1/2x1-1/4 1-1/32 1-3/32 1-1/32 2-13/32 2-11/32 2-13/32 4-13/16 2-11/32 2-1/8 2-11/32 .49 4201-213 1-1/2x1-1/2x2 1-9/32 1-5/32 1-9/32 2-21/32 2-21/32 2-21/32 5-11/32 2-11/32 2-29/32 2-11/32 .64 4201-248 2x2x3/4 11/16 1-13/32 11/16 2-7/32 2-7/16 2-7/32 4-7/16 2-27/32 1-3/8 2-27/32 .52 4201-249 2x2x1 27/32 1-13/32 27/32 2-11/32 2-9/16 2-11/32 4-23/32 2-7/8 1-3/4 2-7/8 .58 4201-250 2x2x1-1/4 1-1/32 1-11/32 1-1/32 2-17/32 2-19/32 2-17/32 5-3/32 2-7/8 2-3/32 2-7/8 .65 4201-251 2x2x1-1/2 1-5/32 1-7/16 1-5/32 2-11/16 2-13/32 2-11/16 5-3/8 2-7/8 2-13/32 2-7/8 .79 4201-289 2-1/2x2-1/2x1 27/32 1-23/32 27/32 2-5/8 2-27/32 2-5/8 5-1/4 3-17/32 1-23/32 3-17/32 1.01 4201-290 2-1/2x2-1/2x1-1/4 1-3/32 1-23/32 1-1/32 2-13/16 2-31/32 2-13/16 5-21/32 3-9/16 2-3/32 3-9/16 1.13 4201-291 2-1/2x2-1/2x1-1/2 1-3/16 1/2 1-3/16 2-15/16 1-7/8 2-15/16 5-7/8 3-15/32 2-11/32 3-15/32 1.26 4201-292 2-1/2x2-1/2x2 1-13/32 1-5/8 1-13/32 3-3/16 3-1/8 3-3/16 6-3/8 3-1/2 2-7/8 3-1/2 1.37 4201-335 3x3x1 7/8 1-15/16 7/8 2-3/4 3-1/16 2-3/4 5-15/32 4-3/16 1-23/32 4-3/16 1.26 4201-336* 3x3x1-1/4 1-3/8 1-3/4 1-3/8 3-5/16 3-1/2 3-5/16 6-5/8 4-1/8 2-7/8 4-1/8 1.94 4201-337 3x3x1-1/2 1-5/32 2-1/16 1-5/32 3-1/32 3-7/16 3-1/32 6-3/32 4-3/16 2-3/8 4-3/16 1.46 4201-338 3x3x2 1-7/16 1-13/16 1-7/16 3-5/16 3-5/16 3-5/16 6-19/32 4-3/16 2-7/8 4-3/16 1.69 4201-339 3x3x2-1/2 1-3/4 1-31/32 1-3/4 3-5/8 3-23/32 3-5/8 7-1/4 4-3/16 3-17/32 4-3/16 2.11 * Branch Outlet Sized with Bushing M H1 H H2 G G2 L G1M2 M1 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 388 SPRINKLER REDUCING HEAD TEE Brass Thread Insert Style Socket x Socket x Fipt Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101 3/4x3/4x1/2 7/16 1-1/16 7/16 1-15/32 1-5/8 1-15/32 2-29/32 1-13/32 1-3/16 1-13/32 .20 4202-124 1x3/4x1/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130 1x1x1/2 7/16 1-7/32 7/16 1-9/16 1-25/32 1-9/16 3-1/8 1-3/4 1-3/16 1-3/4 .26 4202-156 1-1/4x1x1/2 7/16 1-7/16 9/16 1-11/16 2-1/32 1-11/16 3-3/8 2-3/32 1-3/16 1-23/32 .30 4202-166 1-1/4x1-1/4x1/2 7/16 1-15/32 7/16 1-11/16 2-1/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .31 4202-199 1-1/2x1-1/4x1/2 1/2 1-5/8 9/16 1-7/8 2-3/16 1-13/16 3-11/16 2-11/32 1-3/16 2-1/16 .37 4202-209 1-1/2x1-1/2x1/2 1/2 1-5/8 1/2 1-7/8 2-3/16 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .38 4202-237 2x1-1/2x1/2 1/2 1-27/32 17/32 2 2-7/16 1-29/32 3-15/16 2-7/8 1-3/16 2-11/32 .47 4202-247 2x2x1/2 1/2 1-7/8 1/2 2 2-7/16 2 4-1/32 2-27/32 1-3/16 2-27/32 .50 Not intended to convey or dispense water for human consumption through drinking or cooking M1 GH L M G1 H1 G2H2 M2 SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Socket x Fipt Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-010 1x1x1 21/31 1-1/8 21/31 1-25/32 1-29/32 1-25/32 3-19/32 1-23/32 1-23/32 1-23/32 .37 Not intended to convey or dispense water for human consumption through drinking or cooking H M G1 H1 M1 H2 G2G M2 L SofTorque™ SR REDUCING TEE Gasket Sealed Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt With Elastomer Seal - Use NO Thread Sealant Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. 4202-101GSR 3/4x3/4x1/2 7/16 1-1/2 7/16 1-3/8 1-7/8 1-3/8 2-3/4 1-5/16 1-3/8 1-5/16 .16 4202-130GSR 1x1x1/2 7/16 1-5/8 7/16 1-1/2 2 1-1/2 3 1-5/8 1-3/8 1-5/8 .20 M M1 H1G1 M2 G2 H2H L G FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 389 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com TorqueSafe™ SPRINKLER HEAD TEE Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt x Socket With Elastomer Seal - Use NO Thread Sealant Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4203-122 G 1x1/2x1 19/32 13/16 1-13/32 1-19/32 1-27/32 1-3/4 3-11/32 1-5/8 1-5/8 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking H2L G H G1 H1 M1 M G2 M2 SPRINKLER REDUCING HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101SR 3/4x3/4x1/2 19/32 25/32 19/32 1-19/32 1-7/16 1-19/32 3-7/32 1-13/32 1-3/16 1-13/32 .15 4202-124SR 1x3/4x1/2 7/16 29/32 9/16 1-19/32 1-5/8 1-9/16 3-5/32 1-23/32 1-3/16 1-17/32 .19 4202-130SR 1x1x1/2 7/16 29/32 7/16 1-9/16 1-5/8 1-9/16 3-1/8 1-23/32 1-3/16 1-23/32 .20 4202-156SR 1-1/4x1x1/2 15/32 1-5/32 19/32 1-23/32 1-7/8 1-23/32 3-13/32 2-3/32 1-3/16 1-23/32 .26 4202-166SR 1-1/4x1-1/4x1/2 7/16 1-1/8 7/16 1-11/16 1-27/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .26 4202-168SR 1-1/4x1-1/4x1 27/32 1-1/32 27/32 2-3/32 1-29/32 2-3/32 4-7/32 2-3/32 1-11/16 2-3/32 .34 4202-199SR 1-1/2x1-1/4x1/2 9/16 1-9/32 17/32 1-15/16 2 1-25/32 3-23/32 2-11/32 1-3/16 2-3/32 .33 4202-209SR 1-1/2x1-1/2x1/2 1/2 1-1/4 1/2 1-7/8 1-31/32 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .35 4202-211SR 1-1/2x1-1/2x1 27/32 1-7/32 27/32 2-7/32 2-1/8 2-7/32 4-15/32 2-11/32 1-23/32 2-11/32 .44 4202-237SR 2x1-1/2x1/2 23/32 1-9/16 3/8 2-7/32 2-9/32 1-3/4 3-31/32 2-7/8 1-3/16 2-11/32 .45 4202-247SR 2x2x1/2 1/2 31/32 1/2 2 1-11/16 19/32 4 2-7/8 1-3/16 2-7/8 .48 4202-287SR 2-1/2x2-1/2x1/2 17/32 1-3/4 17/32 2-9/32 2-1/2 2-9/32 4-19/32 3-1/2 1-7/32 3-1/2 .78 SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-010SR 1x1x1 21/32 3/4 21/32 1-25/32 1-5/8 1-25/32 3-19/32 1-23/32 1-11/16 1-23/32 .26 LH M G1 H1 M1 H2 G2G M2 H1 M H G L G1 M1 G2 H2 M2 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 390 STREET TEE Spigot x Socket x Socket Part Number Size G G1 G2 H H1 H2 L M1 M2 Approx. Wt. (Lbs.) 4244-007 3/4 13/16 27/32 27/32 1-13/16 1-7/8 1-7/8 3-5/8 1-13/32 1-13/32 .16 4244-010 1 1-5/32 1-1/32 1-1/32 2-1/8 1-29/32 1-29/32 4-3/16 1-3/4 1-3/4 .27 4244-012 1-1/4 1-1/4 1 1 2-7/16 2-9/32 2-9/32 4-27/32 2-3/32 2-3/32 .42 4244-015 1-1/2 1-13/16 1-1/8 1-1/8 2-7/8 2-9/16 2-9/16 5-11/32 2-11/32 2-11/32 .56 4244-020 2 1-23/32 1-7/16 1-13/32 3-1/4 2-15/16 2-15/16 6-5/32 2-7/8 2-7/8 .84 M1 PIPEO.D. H H1 L H2 M2 G1 G G2 SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x SR Fipt x Socket Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4203-122SR 1x1/2x1 27/32 23/32 1-3/32 1-23/32 1-5/8 1-25/32 3-13/32 1-3/4 1-3/4 1-3/16 .21 L G H G1 H1 M1 M H2 G2 M2 SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Fipt x Socket Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4203-122 1x1/2x1 23/32 3/4 1-1/4 1-5/8 1-5/8 1-15/16 3-1/2 1-23/32 1-23/32 1-3/16 .25 Not intended to convey or dispense water for human consumption through drinking or cooking H2L G H G1 H1 M1 M G2 M2 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 391 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com REDUCING 90° ELBOW Socket x Socket Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4206-131 1x3/4 21/32 13/16 1-25/32 1-13/16 1-19/32 1-5/16 .11 H1 G1 M1 H G M SIDE OUTLET ELBOW Socket x Socket x Socket Part Number Size G H M Approx. Wt. (Lbs.) 4213-007 3/4 27/32 1-19/32 1-5/16 .09 4213-010 1 13/16 1-7/8 1-5/8 .18 H G M 90° ELBOW Socket x Socket Part Number Size G H M Approx. Wt. (Lbs.) 4206-007 3/4 9/16 1-1/2 1-5/16 .07 4206-010 1 3/4 1-5/8 1-5/8 .11 4206-012 1-1/4 15/16 2-3/16 2 .22 4206-015 1-1/2 1-5/32 2-17/32 2-3/8 .41 4206-020 2 1-13/32 2-29/32 2-7/8 .62 4206-025 2-1/2 1-15/32 3-3/8 3-1/2 1.15 4206-030 3 1-29/32 3-13/16 4-7/32 1.83 H M G FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 392 SofTorque™ SR 90° ELBOW SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt With Elastomer Seal - Use NO Thread Sealant Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101GSR 3/4x1/2 7/16 1-17/32 1-3/8 1-27/32 1-11/32 1-3/8 .17 4207-130GSR 1x1/2 7/16 1-11/16 1-1/2 2 1-21/32 1-3/8 .19 4207-166GSR 1-1/4x1/2 7/16 1-7/8 1-11/16 2-7/32 2 1-3/8 .22 M H G G1 H1 M1 SPRINKLER HEAD 90° ELBOW Brass Thread Insert Style Socket x Fipt Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101 3/4x1/2 1/2 1-3/32 1-1/2 1-5/8 1-13/32 1-3/16 .17 4207-130 1x1/2 7/16 1-7/32 1-19/32 1-25/32 1-23/32 1-3/16 .21 4207-131 1x3/4 17/32 1-11/32 1-21/32 1-31/32 1-23/32 1-3/8 .25 4207-166 1-1/4x1/2 15/32 1-17/32 1-11/16 1-15/16 2-3/32 1-17/32 .33 Not intended to convey or dispense water for human consumption through drinking or cooking G H M1 G1 H1 M TorqueSafe™ 90° SPRINKLER HEAD ELBOW Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant G H M1 H1 M G1 Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101 G 3/4x1/2 9/16 1-7/32 1-13/32 1-17/32 1-13/32 1-3/8 .19 4207-130 G 1x1/2 7/16 1-3/16 1-9/16 1-11/16 1-23/32 1-3/8 .23 4207-166 G 1-1/4x1/2 15/32 1-19/32 1-15/16 1-11/16 2-3/32 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 393 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com 22-1/2° ELBOW Socket x Socket Part Number Size H J M Approx. Wt. (Lbs.) 4216-007 3/4 1-3/16 7/32 1-13/32 .09 4216-010 1 1-3/8 9/32 1-25/32 .14 4216-012 1-1/4 1-1/2 5/16 2-3/32 .20 4216-015 1-1/2 1-7/16 13/32 1-3/8 .19 4216-020 2 1-7/8 3/8 2-27/32 .43 4216-025 2-1/2 2-7/32 15/32 3-1/2 .72 4216-030 3 2-3/8 1/2 4-5/32 1.00 90° STREET ELBOW Spigot x Socket Part Number Size G G1 H H1 M1 Approx. Wt. (Lbs.) 4209-007 3/4 29/32 19/32 1-15/16 1-11/16 1-13/32 .12 4209-010 1 1-3/32 27/32 2-7/32 1-7/32 1-23/4 .20 4209-012 1-1/4 1-9/16 27/32 2-13/16 2-3/32 2-3/32 .32 4209-015 1-1/2 1-15/32 1-3/16 2-27/32 2-9/16 2-11/32 .42 4209-020 2 1-23/32 1-3/8 3-7/32 2-15/16 2-27/32 .65 SPRINKLER HEAD 90° ELBOW Special Reinforced Plastic Thread Style Socket x SR Fipt Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101SR 3/4x1/2 11/32 13/16 1-15/32 1-1/2 1-13/32 1-3/16 .14 4207-130SR 1x1/2 7/16 7/8 1-9/16 1-5/8 1-23/32 1-3/8 .20 4207-131SR 1x3/4 1/2 7/8 1-5/8 1-9/16 1-23/32 1-3/8 .16 4207-166SR 1-1/4x1/2 13/32 1-1/32 1-21/32 1-23/32 2-3/32 1-7/32 .19 M H J PIPE O.D. H1 G1 G H M1 G H M M1 G1 H1 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 394 45° ELBOW Socket x Socket J H M Part Number Size H J M Approx. Wt. (Lbs.) 4217-007 3/4 1-11/32 13/32 1-5/16 .07 4217-010 1 1-13/32 3/8 1-5/8 .11 4217-012 1-1/4 1-5/8 3/8 2-1/8 .24 4217-015 1-1/2 1-13/16 7/16 2-13/32 .32 4217-020 2 2-1/8 5/8 2-7/8 .47 4217-025 2-1/2 2-17/32 3/4 3-1/2 .88 4217-030 3 2-29/32 29/32 4-5/32 1.16 22-1/2° STREET ELBOW Spigot x Socket PIPE O.D. M1 H H1 J J1 Part Number Size H H1 J J1 M1 Approx. Wt. (Lbs.) 4242-007 3/4 1-1/4 1-1/2 1/4 1/2 1-3/8 .08 4242-010 1 1-7/16 1-11/32 5/16 7/32 1-23/32 .14 4242-012 1-1/4 1-9/16 1-25/32 17/32 11/16 2-1/16 .21 4242-015 1-1/2 1-13/32 1-23/32 1/2 11/32 2-11/32 .28 4242-020 2 1-29/32 2-1/8 7/32 5/8 2-7/8 .42 4242-025 2-1/2 2-7/32 2-7/32 15/32 15/32 3-1/2 .68 4242-030 3 2-13/32 2-13/32 9/16 17/32 4-5/32 .99 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 395 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com CROSS Socket x Socket x Socket x Socket L1 L HG H1 G1 M Part Number Size G G1 H H1 L L1 M Approx. Wt. (Lbs.) 4220-007 3/4 5/8 5/8 1-21/32 1-21/32 3-5/16 3-5/16 1-13/32 .22 4220-010 1 3/4 3/4 1-5/8 1-5/8 3-1/4 3-1/4 1-23/32 .23 4220-012 1-1/4 1-1/8 1-1/8 2-3/8 2-3/8 4-3/4 4-3/4 2-3/32 .63 4220-015 1-1/2 1-7/32 1-7/32 2-5/8 2-5/8 5-7/32 5-7/32 2-3/8 .80 4220-020 2 1-1/2 1-1/2 33663 1.36 4220-025 2-1/2 1-11/16 1-11/16 3-7/16 3-7/16 6-7/8 6-7/8 3-17/32 2.16 4220-030 3 2-3/32 2-3/32 3-31/32 3-31/32 7-15/16 7-15/16 4-7/16 3.37 45° STREET ELBOW Spigot x Socket J1H1 M1 JH PIPE O.D. Part Number Size H H1 J J1 M1 Approx. Wt. (Lbs.) 4227-010 1 1-1/2 1-3/8 1/2 11/4 1-5/8 .10 4227-012 1-1/4 1-25/32 1-9/16 9/16 11/32 1-31/32 .15 4227-015 1-1/2 2-1/32 2-1/8 19/32 25/32 2-11/32 .29 4227-020 2 2-5/16 1-15/16 25/32 13/32 2-7/8 .44 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 396 COUPLING Socket x Socket N L M Part Number Size L M N Approx. Wt. (Lbs.) 4229-007 3/4 1-31/32 1-5/16 3/32 .05 4229-010 1 2-3/16 1-5/8 3/32 .08 4229-012 1-1/4 2-19/32 2 3/32 .13 4229-015 1-1/2 2-7/8 2-11/32 3/32 .22 4229-020 2 3-1/8 2-27/32 3/32 .32 4229-025 2-1/2 3-11/16 3-15/32 3/16 .48 4229-030 3 4 4-3/16 1/4 .89 REDUCING CROSS Socket x Socket x Socket x Socket M L G H G1 H1 L1 M1 Part Number Size G G1 H H1 L L1 M M1 Approx. Wt. (Lbs.) 4220-131 1x3/4 23/32 5/8 1-5/8 1-5/8 3-1/4 3-1/4 1-7/8 1-1/2 .31 4220-167 1-1/4x3/4 1-1/16 23/32 2-1/16 1-31/32 4-3/32 3-31/32 2-1/16 1-13/32 .35 4220-210 1-1/2x3/4 11/16 1-5/32 2-3/32 2-3/16 4-3/16 4-11/32 2-3/8 1-13/32 .42 4220-248 2x3/4 11/16 1-7/16 2-7/32 2-7/16 4-13/32 4-7/8 2-29/32 1-13/32 .56 4220-289 2-1/2x1 29/32 1-3/4 2-11/16 2-7/8 5-11/32 5-3/4 3-1/2 1-3/4 .98 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 397 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com GripLoc™ PUSH-ON COUPLING – LEAD FREE w/EPDM O-Ring Seals Push-On Compression 175 psi Maximum Internal Pressure @ 150°F Part Number Size L L1 M Approx. Wt. (Lbs.) GL4229-007 3/4 4 1-9/16 1-15/16 .26 GL4229-010 1 4-1/8 1-15/16 2-1/4 .35 L M L1 WARNING: DO NOT INSERT FINGERSWARNING: DO NOT INSERT FINGERS.. REDUCER COUPLING Socket x Socket N L M1M Part Number Size L M M1 N Approx. Wt. (Lbs.) 4229-131 1x3/4 2-3/8 1-23/32 1-13/32 7/32 .10 4229-167 1-1/4x3/4 2-19/32 2-3/32 1-5/8 11/32 .17 4229-168 1-1/4x1 2-11/16 2-3/32 1-23/32 5/16 .18 4229-210 1-1/2x3/4 2-13/16 2-11/32 1-13/32 15/32 .19 4229-211 1-1/2x1 2-7/8 2-11/32 1-15/16 3/8 .24 4229-212 1-1/2x1-1/4 2-13/16 2-13/32 2-1/8 5/32 .23 4229-248 2x3/4 3-3/16 2-7/8 1-7/16 23/32 .32 4229-249 2x1 3-1/8 2-7/8 1-23/32 1/2 .31 4229-250 2x1-1/4 3-3/16 2-7/8 2-1/8 17/32 .33 4229-251 2x1-1/2 3-3/16 2-27/32 2-11/32 9/32 .31 4229-291 2-1/2x1-1/2 3-23/32 3-15/32 2-11/32 21/32 .51 4229-292 2-1/2x2 3-21/32 3-1/2 2-7/8 13/32 .52 4229-337 3x1-1/2 3-1/2 4-3/16 2-3/8 7/32 .71 4229-339 3x2-1/2 3-27/32 4-3/16 3-1/2 3/16 .80 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 398 FEMALE ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt N L M M1 Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-007SR 3/4 1-7/8 1-13/32 1-3/8 3/32 .08 4235-010SR 1 2-5/32 1-23/32 1-7/8 3/32 .22 4235-012SR 1-1/4 2-5/16 2-1/8 2-1/16 3/16 .20 FEMALE ADAPTER Brass Thread Insert Style Socket x Fipt Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-007 3/4 2 1-13/32 1-3/8 5/16 .23 4235-010 1 2-3/16 1-3/4 1-11/16 11/32 .25 4235-012 1-1/4 2-3/8 2-3/32 2-1/16 3/8 .36 4235-015 1-1/2 2-17/32 2-11/32 2-7/16 3/8 .49 4235-020 2 2-25/32 2-27/32 3-3/16 7/16 1.05 Not intended to convey or dispense water for human consumption through drinking or cooking GROOVED COUPLING ADAPTER Groove x Socket Part Number Size L M1 N Approx. Wt. (Lbs.) 4233-012 1-1/4 3-5/8 2-3/32 2-11/32 .72 4233-015 1-1/2 3-3/4 2-11/32 2-11/32 .83 4233-020 2 3-27/32 2-27/32 2-11/32 1.27 4233-025 2-1/2 4-3/16 3-15/32 2-7/16 2.02 4233-030 3 4-5/32 4-1/8 2-7/16 2.79 Not intended to convey or dispense water for human consumption through drinking or cooking N L M M1 N L PIPEO.D.M1 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 399 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread w/Metal Thread Start Socket x SR Fipt M L N M1 Part Number Size L M M1 N Approx. Wt. (Lbs.) Z4235-101SR 3/4x1/2 1-7/8 1-3/8 1-7/16 3/16 .08 FEMALE REDUCING SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt M1M LN Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101SR 3/4x1/2 1-29/32 1-13/32 1-3/16 1/8 .08 4235-130SR 1x1/2 1-15/16 1-23/32 1-3/8 3/32 .16 4235-131SR 1x3/4 2-3/32 1-3/4 1-3/8 1/4 .13 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Socket Wrench Flats Socket x SR Fipt M L M1 N Part Number Size L M M1 N Approx. Wt. (Lbs.) W4235-101SR 3/4x1/2 2-9/32 1-13/32 1-3/16 17/32 .09 W4235-130SR 1x1/2 2-9/32 1-3/4 1-3/16 13/32 .12 M = Flat-to-Flat Dimension FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 400 TorqueSafe™ FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101 G 3/4x1/2 1-7/8 1-13/32 1-3/8 17/32 .15 4235-130GS 1x1/2 2-1/32 1-11/16 1-3/8 17/32 .17 4235-131 G 1x3/4 2 1-11/16 1-9/16 9/16 .18 Not intended to convey or dispense water for human consumption through drinking or cooking N L M M1 SPIGOT FEMALE ADAPTER Brass Thread Insert Style Spigot x Fipt N L PIPEO.D.M1 Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-007 3/4 2-5/32 1-3/8 17/32 .15 4278-010 1 2-9/32 1-11/16 7/16 .22 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt N L PIPEO.D.M1 Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-007SR 3/4 1-15/16 1-3/8 11/32 .08 4278-010SR 1 2-1/4 1-23/32 13/32 .13 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 401 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style with Long Body Socket x Fipt Part Number Size L M M1 N Approx. Wt. (Lbs.) L4235-130 1x1/2 2-3/16 1-23/32 1-7/32 1/2 .19 Not intended to convey or dispense water for human consumption through drinking or cooking N L M M1 FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Fipt N L M M1 Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101 3/4x1/2 1-7/8 1-13/32 1-17/32 15/32 .19 4235-130 1x1/2 2-11/32 1-11/16 1-3/16 5/8 .16 4235-131 1x3/4 2-5/16 1-11/16 1-3/8 17/32 .18 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorque™ SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt With Elastomer Seal - Use NO Thread Sealant Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101GSR 3/4x1/2 2-5/16 1-5/16 1-3/8 31/32 .11 4235-130GSR 1x1/2 2-13/32 1-19/32 1-3/8 31/32 .13 4235-131GSR 1x3/4 2-13/32 1-5/8 1-23/32 1 .16 N L M1M FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 402 SPIGOT FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Spigot x Fipt Part Number Size L M1 N Approx. Wt. (Lbs.) 4238-101 3/4x1/2 2-5/32 1-7/32 19/32 .12 4238-130 1x1/2 2-1/4 1-3/16 11/32 .19 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style with Positioning Ring Socket x Fipt Part Number Size L M M1 N Approx. Wt. (Lbs.) R4235-101 3/4x1/2 2-1/32 1-7/16 1-3/16 15/32 .15 Not intended to convey or dispense water for human consumption through drinking or cooking N L M M1 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Positioning Ring Socket x SR Fipt Part Number Size L M M1 N Approx. Wt. (Lbs.) R4235-101SR 3/4x1/2 1-15/16 1-7/16 1-7/32 7/32 .09 N L M M1 TorqueSafe™ FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Spigot x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant Part Number Size L M N Approx. Wt. (Lbs.) 4238-101 G 3/4x1/2 1-15/16 1-3/8 17/32 .14 4238-130 G 1x1/2 2-1/16 1-3/8 19/32 .15 Not intended to convey or dispense water for human consumption through drinking or cooking NL M1PIPEO.D. N L M1PIPEO.D. FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 403 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com MALE ADAPTER With CPVC Lined Thread Brass Insert Mipt x Socket Part Number Size L M1 N Approx. Wt. (Lbs.) 4236-007 3/4 2-17/32 1-13/32 13/16 .26 4236-010 1 2-15/16 1-23/32 29/32 .43 4236-012 1-1/4 3-1/8 2-3/32 31/32 .66 4236-015 1-1/2 3-9/32 2-11/32 31/32 .80 4236-020 2 3-7/16 2-27/32 31/32 1.00 N L M1 BUSHING with BRASS THREAD INSERT Spigot x Fipt Part Number Size L Approx. Wt. (Lbs.) 4238-130BR 1x1/2 1 .13 Not intended to convey or dispense water for human consumption through drinking or cooking PIPEO.D. L SPIGOT FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt Part Number Size L M1 N Approx. Wt. (Lbs.) 4238-101SR 3/4x1/2 1-29/32 1-7/32 1/8 .07 4238-130SR 1x1/2 2-1/32 1-7/32 7/32 .09 N L M1PIPEO.D. TorqueSafe™ BUSHING - GASKET SEALED Brass Thread Insert Style Spigot x Gasket Fipt` With Elastomer Seal - Use NO Thread Sealant Part Number Size L Approx. Wt. (Lbs.) 4238-130BR G 1x1/2 1-5/32 .10 Not intended to convey or dispense water for human consumption through drinking or cooking PIPEO.D. L FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 404 REDUCER BUSHING Flush Style Spigot x Socket Part Number Size L N Approx. Wt. (Lbs.) 4237-131 1x3/4 1-1/4 1/4 .04 4237-167 1-1/4x3/4 1-7/16 7/16 .10 4237-168 1-1/4x1 1-13/32 9/32 .06 4237-210 1-1/2x3/4 1-5/8 5/8 .19 4237-211 1-1/2x1 1-17/32 13/32 .13 4237-212 1-1/2x1-1/4 1-9/16 5/16 .07 4237-248 2x3/4 1-29/32 29/32 .28 4237-249 2x1 1-23/32 9/16 .23 4237-250 2x1-1/4 1-11/16 7/16 .21 4237-251 2x1-1/2 1-11/16 5/16 .15 4237-290 2-1/2x1-1/4 2-5/32 7/8 .41 4237-291 2-1/2x1-1/2 2-5/32 3/4 .39 4237-292 2-1/2x2 2-9/32 3/4 .28 4237-338 3x2 2-7/32 11/16 .63 4237-339 3x2-1/2 2-5/16 1/4 .42 L PIPE O.D. N ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt Part Number Size LNQ Body Width Approx. Wt. (Lbs.) Min Max Min Max 42004SR 3/4x1/2 6-23/32 8-11/32 4-29/32 6-17/32 1-1/4 2-3/16 .66 42014SR 1x1/2 6-3/4 8-13/32 4-29/32 6-9/16 1-1/4 2-3/16 .67 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt Part Number Size LNQ Body Width Approx. Wt. (Lbs.) Min Max Min Max 42001SR 3/4x1/2 6-5/8 8-11/32 4-7/8 6-19/32 1-1/4 2-3/16 .66 42011SR 1x1/2 6-23/32 8-7/16 4-27/32 6-9/16 1-1/4 2-3/16 .69 N L Q BodyWidth LN Q BodyWidth PIPEO.D. FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 405 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com TEST PLUG - O-Ring Sealed Mipt - For Pressure Testing Only. Not For use with Gasket Sealed or Z4235 Series Adapters M 1/2-14 NPT M1 L Part Number Size L M M1 Approx. Wt. (Lbs.) FTP-005 1/2 1-27/32 1-15/16 1-7/32 .03 CAP Socket Part Number Size M W Approx. Wt. (Lbs.) 4247-007 3/4 1-3/8 1-13/32 .05 4247-010 1 1-5/8 1-9/16 .06 4247-012 1-1/4 2-3/32 1-27/32 .13 4247-015 1-1/2 2-11/32 2 .17 4247-020 2 2-27/32 2-9/32 .39 4247-025 2-1/2 3-17/32 2-5/8 .50 4247-030 3 4-3/8 3 .92WMTRANSITION BUSHING IPS Spigot x CTS Socket Part Number Size L N Approx. Wt. (Lbs.) 4240-101 3/4x1/2 1-1/8 5/8 .03 4240-130 1x1/2 1-1/4 23/32 .05 PIPEO.D. L N FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 406 FLANGE - ONE PIECE 4 Bolt Holes, 175 psi Socket M BOLT CIRCLE DIA. MAX O.D. N RL Part Number Size L M N R No. of Bolt Holes Bolt Circle Dia. Bolt Size Min. Bolt Length Max. O.D. Approx. Wt. (Lbs.) 4251-007 3/4 1-5/32 1-1/2 1/8 17/32 4 2-3/4 1/2 2 3-29/32 .31 4251-010 1 1-5/16 1-13/16 1/8 11/16 4 3-1/8 1/2 2-1/4 4-9/32 .35 4251-012 1-1/4 1-13/32 2-7/32 5/32 11/16 4 3-1/2 1/2 2-1/4 4-5/8 .44 4251-015 1-1/2 1-19/32 2-1/2 3/16 23/32 4 3-27/32 1/2 2-1/2 5-1/16 .61 4251-020 2 1-27/32 3 5/16 27/32 4 4-3/4 5/8 3 5-31/32 .95 4251-025 2-1/2 2-7/32 3-1/2 7/16 1-1/32 4 5-1/2 5/8 3-1/4 7 1.50 TEST PLUG (PVC White) Not UL Listed Mipt - For Pressure Testing Only. L Part Number Size L Approx. Wt. (Lbs.) 4250-005 1/2 27/32 .02 TEST PLUG for TorqueSafe™ Gasket Sealed Head Adapters Mipt - For Pressure Testing Only. Use ONLY with Gasket Sealed Head Adapters M 1/2-14 NPT M1 L Part Number Size L M M1 Approx. Wt. (Lbs.) FTP-005GS 1/2 1-25/32 2-1/32 1-1/4 .05 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 407 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com FLANGE - TWO PIECE Van Stone Style, 4 Bolt Holes, 175 psi Spigot Part Number Size L N R Bolt Circle Dia. No. of Bolt Holes Bolt Size Min. Bolt Length Max. O.D. Approx. Wt. (Lbs.) 4256-007 3/4 1-15/16 13/16 17/32 2-3/4 4 1/2 2 3-27/32 .30 4256-010 1 2-7/32 1-1/32 11/16 3-1/8 4 1/2 2-1/4 4-1/4 .41 4256-012 1-1/4 2-3/8 1 11/16 3-1/2 4 1/2 2-1/4 4-5/8 .50 4256-015 1-1/2 2-7/16 1-3/32 23/32 3-7/8 4 1/2 2-1/2 4-31/32 .65 4256-020 2 2-3/4 1-5/32 25/32 4-3/4 4 5/8 3 5-15/16 1.00 4256-025 2-1/2 3-1/16 1-9/32 1-1/32 5-1/2 4 5/8 3-1/4 6-15/16 1.62 4256-030 3 3-3/8 1-13/32 1-1/32 6 4 5/8 3-1/4 7-9/16 1.76 FLANGE - TWO PIECE Van Stone Style, 4 Bolt Holes, 175 psi Socket Part Number Size L M N R Bolt Circle Dia. No. of Bolt Holes Bolt Size Min. Bolt Length Max. O.D. Approx. Wt. (Lbs.) 4254-030 3 2-1/8 4-1/4 9/32 1-1/32 6 4 5/8 3-1/4 7-15/32 1.75 BLIND FLANGE 4 Bolt Holes, 175 psi Part Number Size R Bolt Circle Dia. No. of Bolt Holes Bolt Size Min. Bolt Length Max. O.D. Approx. Wt. (Lbs.) 4253-007 3/4 17/32 2-3/4 4 1/2 2 3-27/32 .30 4253-010 1 23/32 3-1/8 4 1/2 2-1/4 4-1/4 .35 4253-012 1-1/4 21/32 3-1/2 4 1/2 2-1/4 4-5/8 .40 4253-015 1-1/2 23/32 3-27/32 4 1/2 2-1/2 5-1/16 .52 4253-020 2 27/32 4-3/4 4 5/8 3 5-31/32 .86 4253-025 2-1/2 1-1/32 5-1/2 4 5/8 3-1/4 6-15/16 1.70 4253-030 3 1-5/16 6 4 5/8 3-1/4 7-5/8 1.72 MAX O.D. PIPE O.D. BOLT CIRCLE DIA.R NL M BOLT CIRCLE DIA. MAX O.D. R N L MAX O.D. BOLT CIRCLE DIA. R FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 408 TRANSITION UNION Brass Thread Insert Style Socket x Fipt Part Number Size L M N Nut O.D. Approx. Wt. (Lbs.) 4259-010BR 1 2-13/16 1-7/8 1-1/32 2-7/8 .52 4259-012BR 1-1/4 3 2-3/16 1-1/8 3-9/32 .98 4259-015BR 1-1/2 3-3/4 2-1/2 1-9/16 3-17/32 .93 4259-020BR 2 3-5/8 2-7/8 1-1/4 4-5/16 1.64 Not intended to convey or dispense water for human consumption through drinking or cooking 175 psi N L MNUT O.D. UNION Socket x Socket N L MNUT O.D. Part Number Size L M N Nut O.D. Approx. Wt. (Lbs.) 4257-007 3/4 2-3/8 1-17/32 3/8 2-1/2 .38 4257-010 1 2-9/16 1-27/32 3/8 2-7/8 .41 4257-012 1-1/4 2-27/32 2-7/32 11/32 3-5/16 .52 4257-015 1-1/2 3-1/8 2-1/2 3/8 3-17/32 .63 4257-020 2 3-5/8 3-1/32 9/16 4-3/16 1.09 175 psi QuickTorque™ SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Metal Fipt With Elastomer Seal - Use NO Thread Sealant Part Number Size L M M1 N Approx. Wt. 4235-130GMR 1x1/2 2-3/16 1-19/32 1-9/16 15/16 .19 N L M M1 FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions Page 409 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com SHORT REPAIR COUPLING Spigot x Socket L2 L1 S M L3 Part Number Size L1 L2 L3 M S Approx. Wt. (Lbs.) SH118-07CO 3/4 4-13/16 5-17/32 3/4 1-3/4 2-3/16 .31 SH118-10CO 1 4-3/4 5-5/8 31/32 2-1/16 2-5/32 .40 175 psi GripLoc™ REPAIR COUPLING – LEAD FREE w/EPDM O-Ring Seals Part Number Size L L1 L2 M S Approx. Wt. (Lbs.) SG118-10CO 1 1-17/32 7-17/32 4-1/4 2-1/4 2-27/32 .73 WARNING: DO NOT INSERT FINGERSWARNING: DO NOT INSERT FINGERS.. L1 L1M LLS L2 SofTorque™ SR FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Spigot x SR Fipt With Elastomer Seal - Use NO Thread Sealant Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-101GSR 3/4x1/2 2-1/4 1-3/8 1 .11 PIPEO.D. N L M1 175 psi Maximum Pressure @ 150°F FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® CPVC True Union Drain & Swing Check Valves for NFPA 13D Applications Only Made in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasDue to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com Page 410 TRUE UNION INDUSTRIAL DRAIN VALVES CPVC Gray Valve with CPVC Orange End Connector Socket x Socket E D A B C Part Number Size A B C D E 1822-007CFG 3/4 2-1/4 2-3/4 4-3/4 2-7/8 3-3/8 1822-010CFG 1 2-1/2 2-7/8 5-1/8 3-1/8 3-7/16 1822-012CFG 1-1/4 3-1/16 3-1/4 5-3/4 3-5/8 3-7/8 1822-015CFG 1-1/2 3-1/2 3-1/2 6-1/4 4 4-3/16 1822-020CFG 2 4-1/4 4-3/4 7-3/4 4-1/2 5-1/8 Not UL Listed FlameGuard®CPVC Drain & Swing Check Valves for NFPA 13D Applications Only Application: FlameGuard® CPVC Orange Swing Check Valves and PVC/CPVC True Union Drain Valves are for use in configuring CPVC Fire Sprinkler System connection to water supply (riser/drain assembly) in NFPA 13D installations only. These valves are not UL Listed and NOT for use in any other locations within the fire sprinkler system. TRUE UNION DRAIN VALVES PVC Valve with CPVC End Connector Socket x Socket D A B C E Part Number Size A B C D E 3622-007FG 3/4 2-1/4 2-3/4 4-3/4 2 3 3622-010FG 1 2-1/2 2-7/8 5-1/8 2-5/16 3-7/16 Not UL Listed FlameGuard® CPVC Fire Sprinkler Products Technical Information FlameGuard® CPVC True Union Drain & Swing Check Valves for NFPA 13D Applications Only Page 411 Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears® Manufacturing Company Due to Material Cost Variations, Prices Subject to Change. Check On-line Catalog @ www.spearsmfg.com CPVC SPECIAL REINFORCED THREAD INLET SWING CHECK VALVES SR Fipt x Socket A B C D Part Number Size A B C D Approx. Wt. (Lbs) S1520-10FSRSCO 1 1-11/16 2-15/16 4-9/16 2-5/8 .33 S1520-12FSRSCO 1-1/4 2-1/16 3-5/8 5-1/2 3-3/8 .42 S1520-15FSRSCO 1-1/2 2-7/16 3-11/16 5-5/8 3-3/8 .89 Not UL Listed CPVC SWING CHECK VALVES Socket x Socket Part Number Size A B C D Approx. Wt. (Lbs) S1520-10CO 1 1-11/16 2-5/16 4-9/16 2-5/8 .33 S1520-12CO 1-1/4 2-1/16 2-15/16 5-1/2 3-3/8 .42 S1520-15CO 1-1/2 2-7/16 3 5-5/8 3-3/8 .89 Not UL Listed A B C D PHD Manufacturing, Inc. SURGE RESTRAINT FUNCTION:Designed to restrict the upward movement of activated fire sprinkler systems.Grips ring hanger, NOT THE NUT, and allows for fine tuning adjustments.Listed for use with PHD Manufacturing, Inc. Figure 141 ring hangers only. SIZE:Pipe size 3/4"(20)thru 2"(50)IP. FINISH:Powder Coating MATERIAL:Spring Steel INSTALL:Installs easily before or after pipe installation and without tools. Simply clip Fig. 055 onto Fig. 141 ring hanger and run the hanger rod down to the bottom plate surface to ensure proper restraint. APPROVALS:Underwriters Laboratories listed for US and Canada Note:For use up to 2”(50)pipe, one size fits all. Fig.055 SURGE RESTRAINT Fig.055 (Pictured With Fig. 141) Unless otherwise specified,all dimensions on drawings and in charts are in inches and dimensions shown in parentheses are in millimeters. 4 For the most up to date information, visit www.itwbuildex.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)UL Test Load (lbs)FM Test Load (lbs)Box Qty CaseQty VERTICAL MOUNT 1/4"8002957 GST 100 1/4 x 1"210 (7/16” OSB)670 (3/4” Ply)25 125 1/4"8003957 GST 200 1/4 x 2"1760 (Fir)25 125 1/4"8004957 GST 300 1/4 x 3"2060 (Fir)25 125 3/8"8007957 GST 10 1/4 x 1"210 (7/16” OSB)670 (3/4” Ply)300 25 125 3/8"8008957 GST 20 1/4 x 2"1760 (Fir)850 1475 25 125 3/8"8068925 GST 20-SS 1/4 x 2"1760 (Fir)850 25 125 3/8"8009925 GST 25-380 3/8 x 2-1/2"2113 (Fir)1500 25 125 3/8"8010957 GST 30 1/4 x 3"2060 (Fir)1500 1475 25 125 3/8"8069925 GST 30-SS 1/4 x 3"2060 (Fir)25 125 3/8"8011925 GST 40 1/4 x 4"2180 (Fir)25 125 1/2"8013925 GST 2 1/4 x 2"1760 (Fir)25 125 1/2"8014925 GST 2.5-380 3/8 x 2-1/2"2113 (Fir)25 125 1/2"8015925 GST 3 1/4 x 3"2275 (Fir)25 125 Not less than2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) #14 Black Nut DriverPart # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes intocontact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / TrussConsult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 11. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Made in the U.S.A. SAMMYS® FOR WOOD Application Product Features Watch a video demonstration atwww.itwbuildex.com SAMMYS® FOR WOOD - Vertical Application Model FCA Valve Size Takeout (Length)Pressure Rating Weight 2" (50mm)19-3/4" (502mm)300 psi (20,7 bar)26 lbs (11.8 kg) 2-1/2" (65mm)21-1/4" (5402mm)250 psi (17,2 bar)40 lbs (18.1 kg) 3" (80mm)21-3/4" (552mm)250 psi (17,2 bar)46.5 lbs (21.1 kg) 4" (100mm)23-1/2" (597mm)250 psi (17,2 bar)62 lbs (28.1 kg) Table AModel FCA Technical Data Features • Compact design • Grooved component connections for universal application • Horizontal and vertical (flow up) installation Product Description The Reliable Model FCA Floor Control Assembly is designed for use as a floor or zone control assembly in NFPA 13 or 13R applications. The product can also be used as a conventional wet system (shotgun) riser. Grooved connections on each com- ponent allow components to be rotated independently, provid- ing maximum flexibility in the field. The assembly includes a butterfly control valve with integral tamper switch, a water flow detector, and a riser check valve with a pressure gauge and a Model TD Test & Drain valve. Multiple orifices and pressure relief options are available for the Model FCA Floor Control As- sembly. www.reliablesprinkler.com Table BModel FCA Equivalent Length of Schedule 10 Pipe Size C = 120 2” (50mm)16.6 2-1/2” (65mm)14.0 3” (80mm)16.3 4” (100mm)20.1 cULus Listed Model FCA Floor Control Assembly For Use in NFPA 13 and NFPA 13R Systems Bulletin 619 July 2019 Figure 1Model FCA Dimensions (Refer to Table D) Size A B C D E F G 2” (50mm)6-3/4” (171mm) 3” (76mm) 5” (127mm) 15-3/4” (400mm) 19-3/4” (502mm) 13-1/2” (343mm) 21-1/2” (546mm) 2-1/2” (65mm)9-1/4” (235mm) 3-1/4” (83mm) 5-1/4” (133mm) 15-1/2” (140mm) 21-1/4” (540mm) 14-1/2” (368mm) 24-1/2” (622mm) 3” (76mm)9-1/2”(241mm)3-1/2”(89mm)5-1/2”(140mm)16-3/4”(425mm)21-3/4”(552mm)14-1/2”(368mm)24-1/2”(622mm) 4” (100mm)10-1/2” (267mm) 4-1/4” (108mm) 7” (178mm) 20” (508mm) 23-1/2” (597mm) 14-1/2” (368mm) 26-1/2” (673mm) Table CModel FCA Dimensions (Refer to Figure 1) Bulletin 619 July 2019 Page 2 of 3 www.reliablesprinkler.com P/N 9999970533Installation The Reliable Model FCA Floor Control Assembly shall be installed in accordance with NFPA 13, NFPA13R, and the requirements of any authorities having jurisdiction. Failure to follow installation instructions and/or revisions to the arrange- ment of the devices may void the warranty and/or listing of the product. Prior to installation, verify compatibility of the Model FCA materials with the water supply and the environ- ment where the valve will be installed. The Model FCA must be installed in a location where the temperature is maintained at a minimum of 40°F (4°C). Heat tracing of wet system valve assemblies is prohibited by NFPA 13. Connect the inlet of the device to the water supply and the outlet of the device to the fire protection system. Ensure proper direction of flow using the diagrams contained in this bulletin and on the device. Drain should be piped to a location that will avoid damage to property and injury to personnel. Maintenance The owner is responsible for maintaining the fire protection system in proper operating condition. Any system main- tenance or testing that involves placing a control valve or detection/control system out of service may eliminate the fire protection that is provided by the fire protection system. Notify any required authorities having jurisdiction and implement appropriate precautions prior to proceeding. When required, the Reliable Model FCA Floor Control Assem- bly and associated equipment shall periodically be given a thorough inspection and test. NFPA 25, “Inspection, Testing and Maintenance of Water Based Fire Protection Systems,” provides minimum maintenance requirements. Replace any components found to be corroded, damaged, or worn. Increase the frequency of inspections when the valve is ex- posed to corrosive conditions or chemicals that could impact the valve materials. Guarantee For Reliable Automatic Sprinkler, Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Ordering Information Specify: • Reliable Model FCA Floor Control Valve Assembly • Size: [2”, 2-1/2”, 3” or 4”] • Water Flow Switch: [System Sensor (standard)] [Potter (optional)] • Orifice Size (K Factor) for Test and Drain Valve: [4.2 (60), 5.6 (80), 8.0 (115), or 11.2 (160) for 2” FCA] [5.6 (80), 8.0 (115), 11.2 (160), or 16.8 (240) for 2-1/2”, 3”, and 4” FCA] • Pressure Relief Valve Kit for Test and Drain Valve: [175, 185, 210, 260, or 310 psi for 2” FCA] [175, 185, 210, or 260 psi for 2-1/2”, 3”, and 4” FCA] 6B WW 00 X YY Z FCA Floor Control Assembly Ordering Information Part Number Figure 2 Riser Check & Manifold Size(1) WW Waterflow Detector Options X Drain Valve Options(1) YY Pressure Relief Valve Options(2) Z 20 = 2”S = System Sensor Flow Detector (Default)01 = 1” RASCO T&D Valve (K2.8)1 = 175psi 25 = 2-1/2”P = Potter Flow Detector 02 = 1” RASCO T&D Valve (K4.2)2 = 185psi 30 = 3”03 = 1” RASCO T&D Valve (K5.6)3 = 210psi 40 = 4”04 = 1-1/4” RASCO T&D Valve (K4.2)4 = 260psi 05 = 1-1/4” RASCO T&D Valve (K5.6)5 = 310psi 06 = 1-1/4” RASCO T&D Valve (K8.0) 07 = 1-1/4” RASCO T&D Valve (K11.2) 08 = 2” RASCO T&D Valve (K5.6) 09 = 2” RASCO T&D Valve (K8.0) 10 = 2” RASCO T&D Valve (K11.2) 11 = 2” RASCO T&D Valve (K16.8) Note: (1): 2” FCA has a 1” drain outlet, 2-1/2” and 3” FCA have a 1-1/4” drain outlet, and 4” FCA has a 2” drain outlet. (2): Pressure Relief Valve option #5 is not available for sizes 2-1/2”, 3”, and 4” FCA. Bulletin 619 July 2019 Page 3 of 3 www.reliablesprinkler.com Rrrr Material List Component Material Body ASTM A-536 Nylon-11 Coated Disc ASTM A-536 EPOM Encapsulated Upper & Lower Stems AISI 420-SS Worm Gear Shaft AISI 410-SS Housing ASTM A-536 Hand Wheel ASTM A-536 Flag Indicator ASTM A-536 Shear Pin ASTM A-510 Segment Gear ASTM B-148 or B-584 Housing Gasket EPDM Grade E O-Rings (All) EPDM Grade E Working Pressure & Temperature Max. Working Pressure: 300PSI / 21.4Bar Max. Test Pressure: 600PSI / 42.8Bar Max. Working Temperature: 120oC Weight & Dimensions Inches / mm SIZE A B C D E F G H Weight 2½” 4.13 (105) 3.30 (85) 3.80 (96.4) 2.87 (73.0) 5.31 (135) 5.04 (128) 5.04 (128) 9.0 Kg 3” 4.41 (112) 3.60 (92) 3.80 (96.4) 3.50 (88.9) 5.59 (142) 5.04 (128) 5.04 (128) 9.5 Kg 4” 5.71 (145) 4.30 (108) 4.54 (115.4) 4.50 (116.2) 6.89 (135) 5.04 (128) 5.04 (128) 11 Kg 6” 7.05 (179) 5.71 (145) 5.21 (132.4) 6.63 (168.3) 8.23 (209) 8.66 (220) 8.66 (220) 0.28 (7.10) 17.4 Kg 8” 8.03 (204) 6.70 (170) 5.80 (147.4) 8.64 (219.1) 9.21 (234) 8.66 (220) 8.66 (220) 0.95 (24.2) 22.8 Kg Ordering Information Description Size Part Number Butterfly Valve FM/UL Grooved 300 PSI (Rasco) 65mm / 2½” 7V00000018 Butterfly Valve FM/UL Grooved 300 PSI (Rasco) 80mm / 3” 7V00000019 Butterfly Valve FM/UL Grooved 300 PSI (Rasco) 100mm / 4” 7V00000020 Butterfly Valve FM/UL Grooved 300 PSI (Rasco) UK 165mm / 6” 7V00000021 Butterfly Valve FM/UL Grooved 300 PSI (Rasco) EU 168mm/ 6” 7V00000022 Butterfly Valve FM/UL Grooved 300 PSI (Rasco) 200mm / 8” 7V00000023 REL-BFG-300 FM & UL Grooved Butterfly Valve Rrrr Wiring Diagram Test Data MFG. #5400930 - REV E09/12PRINTED IN USA PAGE 1 OF 3 PS40 SERIES SUPERVISORY PRESSURE SWITCH Installation The Potter PS40 Series Supervisory Pressure Actuated Switches are designed primarily to detect an increase and/or decrease from normal system pressure in automatic fire sprinkler systems. Typical applications are: Dry pipe systems, pre-action air/nitrogen supervision, pressure tanks, air supplies, and water supplies. The PS40 switch is factory set for 40 PSI (2,8 BAR) normal system pressure. The switch marked with the word LOW is set to operate at a pressure decrease of 10 PSI (,7 BAR) at 30 PSI (2,1 BAR). The switch marked with the word HIGH is set to operate at a pressure increase of 10 PSI (,7 BAR) at 50 PSI (3,5 BAR). See section heading Adjustments and Testing if other than factory set point is required. 1. Connect the PS40 to the system side of any shutoff or check valve. 2. Apply Teflon tape to the threaded male connection on the device. (Do not use pipe dope) 3. Device should be mounted in the upright position. (Threaded connection down) 4. Tighten the device using a wrench on the flats on the device. Wiring Instructions 1. Remove the tamper resistant screw with the special key provided. 2. Carefully place a screwdriver on the edge of the knockout and sharply apply a force sufficient to dislodge the knockout plug. See Fig. 9 3. Run wires through an approved conduit connector and affix the connector to the device. A NEMA-4 rated conduit fitting is required for outdoor use. UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Dimensions: 3.78" (9,6cm)W x 3.20" (8,1cm)D x 4.22" (10,7cm)H Conduit Entrance: Two knockouts provided for 1/2" conduit. Individual switch compartments and ground screw suitable for dissimilar voltages Enclosure: Cover- Die-cast with textured red powdercoat finish, single cover screw and rain lip. Base- Die-cast Pressure Connection: Nylon 1/2" NPT male Factory Adjustment: PS40-1 operates on decrease at 30 PSI (2,1 BAR) PS40-2 operates in increase at 50 PSI (3,5 BAR) and on decrease at 30 PSI (2,1 BAR) Pressure Range: 10-60 PSI (,7 - 4,1 BAR) Differential: Typical 1 lb. at 10 PSI (,07 at ,7 BAR) 4 lbs at 60 PSI (,28 at 4,1 BAR) Maximum System Pressure: 300 PSI (20,68 BAR) Switch Contacts: SPDT (Form C) 10.1 Amps at 125/250VAC, 2.0 Amps at 30VDC One SPDT in PS40-1, Two SPDT in PS40-2 Environmental Specifications: NEMA 4/IP66 Rated Enclosure - indoor or outdoor when used with NEMA 4 conduit fittings. Temperature range: -40°F to 140°F (-40°C to 60°C) Tamper: Cover incorporates tamper resistant fastener that requires a special key for removal. One key is supplied with each device. For optional cover tamper switch kit, order Stock No. 0090200. See bulletin #5401200 PSCTSK.Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential Occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-0988/Canada 888-882-1833 • www.pottersignal.com Ordering Information Model Description Stock No.PS40-1 Pressure switch with one set SPDT contacts 1340403 PS40-2 Pressure switch with two sets SPDT contacts 1340404 Hex Key 5250062 Cover Tamper Switch Kit 0090200 BVL Bleeder valve 1000018 4. Connect the wires to the appropriate terminal connections for the service intended. See Figures 2,4,5,6, and 8 Adjustment And Testing The operation of the pressure supervisory switch should be tested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Note: Testing the PS40 may activate other system connected devices. The use of a Potter BVL (see product bulletin 8900067 for details) is recommended to facilitate setting and testing of the PS40 pressure switch. When a BVL (bleeder valve) is used, the pressure to the switch can be isolated and bled from the exhaust port on the BVL without effecting the supervisory pressure of the entire system. See Fig. 3 The operation point of the PS40 Pressure Switch can be adjusted to any point between 10 and 60 PSI (0,7 - 4,11 BAR) by turning the adjustment knob(s) clockwise to raise the actuation point and counter clockwise to lower the actuation point. In the case of the PS40-2, both switches operate independent of each other. Each switch may be independently adjusted to actuate at any point acrosss the switch adjustment range. Initial adjustment can be made with a visual reference from the top of the adjustment knob across to the printed scale on the switch bracket. Final adjustments should be verified with a pressure gauge. MFG. #5400930 - REV E09/12PRINTED IN USA PAGE 2 OF 3 PS40 SERIES SUPERVISORY PRESSURE SWITCH Typical Sprinkler Applications Switch Clamping Plate TerminalDimensions OUTGOI N G INCOM IN G DWG# 923-3 Fig. 1 Fig. 2 Fig. 3 GONGMOTORWATER TESTBY-PASSWATER VALVEOS & Y VALVE ALARMPRESSURESWITCH PS10 CHECKVALVE VALVECHECK BVLVALVETESTBLEEDER AIR LINESHUT-OFFVALVE PS40 SUPERVISORY PRESSURE SWITCH DWG. #924-1A RBVS DRY PIPEVALVE Typical Connections Fig. 4 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. NOTE: To prevent leakage, apply Teflon tape sealant to male threads only. 2.87[72.97] 4.22 [107.19] 2.48 [62.87] 3.78[95.89] 3.20[81.28] 1.60 [40.64] GROUNDSCREWS DWG# 930-1 1/2" NPT ADJUSTMENTKNOB COM1 2 EOLRTO FIRE ALARM PANEL TO FIRE ALARM PANEL COM12 21COM HIGH AIR LOW AIR PS40-1 PS40-2WITH NORMAL SYSTEM PRES-SURE APPLIED LOW -TERMINAL 2 CLOSES ON PRESSURE DROP. WITH NORMAL SYSTEM PRESSURE APPLIED HIGH - TERMINAL 1 WILL CLOSE ON PRESSURE INCREASE. EOLR DWG# 930-2 Closing of any shutoff valves between the alarm check valve and the PS10 will render the PS10 inoperative. To comply with IBC, IFC, and NFPA-13, any such valve shall be electrically supervised with a supervisory switch such as Potter Model RBVS. MFG. #5400930 - REV E09/12PRINTED IN USA PAGE 3 OF 3 PS40 SERIES SUPERVISORY PRESSURE SWITCH DWG# 928-4 Break out thin section of divider to provide path for wires when wiring both switches from one conduit entrance. One Conduit Wiring Fig. 6 Fig. 8 DWG#928-5 Fig. 9 Removing Knockouts C C C 12 C 12 LOW PRESSURE SWITCH HIGH PRESSURE SWITCH DWG# 930-3 Changing Pressure Low Pressure Signal Connection EOLR TO FIRE ALARM PANEL DWG# 928-1 EOLR TO FIRE ALARM PANEL DWG# 928-2 High Pressure Signal Connection Fig. 5 Fig. 7 (With normal system pressure) Engineer/Architect Specifications Pressure Type Waterflow Switch Pressure type supervisory switches; shall be a Model PS40 as manufactured by Potter Electric Signal Company, St. Louis, MO., and shall be installed on the fire sprinkler system as shown and or specified herein. Switches shall be provided with a 1/2" NPT male pressure connection to be connected into the air supply line on the system side of any shut-off valve. A Model BVL bleeder valve as supplied by Potter Electric Signal Company of St. Louis, MO., or equivalent shall be connected in line with the PS40 to provide a means of testing the operation of the supervisory switch. (See Fig. 3) The switch unit shall contain SPDT (Form C) switch(es). One switch shall be set to operate at a pressure decrease of 10 PSI (0,7 BAR) from normal. If two switches are provided, the second switch shall be set to operate at a pressure increase of 10 PSI (0,7 BAR) from normal. Switch contacts shall be rated at 10.1 Amps at 125/250VAC and 2.0 Amps at 30VDC. The units shall have a maximum pressure rating of 300 PSI (20,68 BAR) and shall be adjustable from 10 to 60 PSI (0,7 to 4,1 BAR). Pressure switches shall have two conduit entrances, one for each individual switch compartment to facilitate the use of dissimilar voltages for each individual switch. The cover of the pressure switch shall be zinc die-cast with rain lip and shall attach with one tamper resistant screw. The pressure switch shall be suitable for indoor or outdoor service with a NEMA-4/IP66 rating. The pressure switch shall be UL, ULC, and CSFM listed, FM and LPC approved and NYMEA accepted. •Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances.•Shock hazard. Disconnect power source before servicing. Serious injury or death could result.•Read all instructions carefully and understand them before starting installation. Save instructions for future use. Failure to read and understand instructions could result in improper operation of device resulting in serious injury or death. •Risk of explosion. Not for use is hazardous locations. Serious injury or death could result. •Do not tighten by grasping the switch enclosure. Use wrenching flats on the bushing only. Failure to install properly could damage the switch and cause improper operation resulting in damage to equipment and property. •To seal threads, apply Teflon tape to male threads only. Using joint compounds or cement can obstruct the pressure port inlet and result in improper device operation and damage to equipment.•Do not over tighten the device, standard piping practices apply. •Do not apply any lubricant to any component of the pressure switch. TerminalC: Common1: Closed when installed under normal system pressure. 2: Open when installed under normal system pressure. Closes on pressure drop. Use for low air signal. Terminal1: Open when installed under normal system pressure. Closes on increase in pressure. Use for high air signal.2: Closed under normal system pressure. Model D Dry Pipe Valve 4 (100mm) & 6 (150mm) Bulletin 351 Rev.R The Reliable Automatic Sprinkler Co., Inc.,103 Fairview Park Drive , Elmsford, New York, 10523 Features 1.Differential Type...simple…light weight construction. 2.Threaded in one piece air and water seat eases maintenance. 3.Bronze seat with “O”-Ring seals minimizes corrosion and leakage. 4.Single hinge pin and latch design no complicated levers. 5.Simpletoreset nospecialtoolsrequired. 6.Tapered air and water seats. 7.Onepiecerubberfacing providesmore reliable rubber-to-metal water seal. 8.Three connections styles available: • ANSI flanged inlet and outlet • ANSI flanged inlet and grooved outlet • Metric flanged inlet and outlet The Reliable Model D Dry Pipe Valve makes pos- sible the installation of automatic sprinkler sys- tems in buildings in which freezing temperatures prevail. Thistypeofsystem,calledaDryPipeSys- tem, has air under pressure instead of water in the piping above the dry pipe valve. When one or more automatic sprinklers operate due to fire, the air pressure in the system is reduced the dry pipe valve opens and water under pressure flows intheactivatedsprinkler(s)andisthendistributed on the fire.Bulletin 351Rev.RListings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. ListedbyUnderwritersLaboratoriesofCanada.(ULC) 3. Certified by FM Approvals 4. Loss Prevention Council. (LPC, UK) 5. NYC BS&A No. 587–75–SA. 6. Scientific Services Laboratories (SSL, Australia) 7. Conforms to EN 12259–3 (CE) Quick Opening Devices When an automatic sprinkler operates, the result- ing air pressure decay is inversely proportional to the size of the dry system – the larger the system, the slower the air pressure decays which slows the operation of the Dry Pipe Valve. NFPA 13,Installa- tion of Sprinkler Systems,specifies that quick opening devices may be required in dry systems having capacities of more than 500 gallons. Reliable’s Model B1 Accelerator is an approved quickopeningdevicethatiseasilyattachedtoReli- able’s Dry PipeValves. Theacceleratoris sensitive to small drops in system pressure and it’s quick op- eration allows the system air to pass through to the alarm outlet andtheundersideof theclapper. Here the air pressure build-up, coupled with the pres- sure of the water supply, opens the dry pipe valve clapper permitting the water to flow instantly to the operated sprinkler(s). Reliable’s Model B1 Accelerator is described in greater detail in Bulletins 320 and 322. Valve Description 1. Rated working pressure 175 psi (12.1 bar). 2. Factoryhydrostatictestpressure:350psi(24.1bar). 3. End and trim connections: Three valve connec- tion styles are available: a. US Standard Flanged Inlet and Outlet: • Flanges mate with ANSI B 16.1 (125 lb.) Flange.• Threaded openings per ANSI B 2.1. • Reliable’s standard trim sets are compati-ble with US Flanged Valves. •Color Black. b. US Standard Flanged Inlet and Grooved Out- let (Fig. 3): •Inlet flange mates with ANSI B 16.1 (125 lb.) flange. •Outlet Groove per ANSI/AWWA C606. Operation The Reliable Model D Dry Pipe Valve in its closed and open positions is shown in Figures 1 and 2. Theclosedpositionismaintainedaslongastheair pressure in the system piping above the dry pipe valveissufficienttoexertagreaterforceonthetop side of the clapper than is exerted on its underside bythepressureofthewatersupply. Sincethearea included by the air seat is approximately six times thatofthewaterseat(TheDifferentialPrinciple)the air pressure needed to keep the dry pipe valve closed is only a fraction of that of the water supply. Table 1 gives the recommended air pressure for various water supply pressures for both sizes of Model D Dry Pipe Valves. Table 1 When one or more automatic sprinklers operate due to fire, the air pressure in the system piping above the dry pipe valve is reduced. The pressure of the water supply, now by exerting the greater force,raisesandrotatestheclappertoitsopenpo- sition, permitting the water to flow to the operated sprinkler(s). Water also flows from the alarm outlet of the dry pipe valve through a strainer to the Reli- able Mechanical Sprinkler Alarm and Electric Alarm Switch to automatically actuate mechanical and electrical alarms. Reliable Model D Dry Pipe Valves can be reset quicklyandeasilywithouttheuseofspecialtools. 2. Water Pressure in Supply Line psi (bar) Air Pressure psi (bar) To be Pumped into System Maximum Not less than Not more than 20 (1,38) 10 (0,68) 20 (1,37) 50 (3,44) 15 (1,03) 25 (1,72) 75 (5,17) 20 (1,37) 30 (2,06) 100 (6,89) 25 (1,72) 35 (2,41) 125 (8,62) 30 (2,06) 40 (2,75) 150 (10,34) 35 (2,41) 45 (3,10) 175 (12,06) 40 (2,75) 50 (3,44) Figure 1—Closed Figure 2—Open U.S. Flange Dimensions in Inches Valve Size Bolt Circle Dia. Bolt Hole Dia. Flange Outside Dia. Flange Thickness No. Bolts 4 6 712 912 34 78 9 11 1516 1 8 8 SUPPLY WATER PRESSURE •Threaded opening per ANSI B 2.1. •Reliable’s standard trim sets are compati- ble with US Flanged and Grooved Valves. •Color Black. c. Metric Flanged Inlet and Outlet: •Flanges mate with EN 1092-2, NF-E-29-282 and BS 4504 PN16 Flanges. •Threaded openings per ISO 7/1 R. •Reliable’s standard trim sets may be used with Metric Valves providing trim is assem- bled carefully and extra thread sealant is applied to connections between valves and trim. •Color Red. 4. Face to Face Dimension: •The 4 (100 mm) Valve 16 (406 mm) •The 6 (150 mm) Valve 19 (482 mm) 5. Shipping Weight: 6.Friction Loss Expressed in Equivalent Length of Pipe, based on Hazen-Williams formula with C = 120: 7. Installation Position: Vertical Trim Description The trimmings for Reliable Model D Dry Pipe Valves (Fig 4) are arranged for rapid, easy and compact attachment and serve as connection points to Reliable Alarm and other devices. They also serve as a means of setting and resetting the dry pipe valve prior to and after operation as well as allowing testing of the alarm devices without causing the system to operate. TheModelDBasicTrimSetisshowninFig.4(The electricsprinkleralarmswitchis not part of thetrim set and must be separately ordered.) This trim set provides the air supply, drain, priming level and alarm connections. An alarm test valve, which al- lows thealarm devices tobetestedwithout operat- ing the dry pipe valve, is included. The basic trim set includes all items such as ball drip valves, pressure gauges, etc which are needed to enable proper dry pipe valve operation. The basic trim set is available in either black or gal- vanized in one of three forms: loose, segmentally as- sembled trim or factory trimmed on the valve. Twoadditionaltrimmingattachmentsareoffered: theprimingchamberattachmentandthefilllineat- tachment. The priming chamber attachment al- lows the priming level to be maintained while the system remains pressurized. The fill line attach- mentprovidesasourceofwaterformaintainingthe prime level. The trimmings, connection, operation and main- tenance of the additional items which comprise a dry pipe valve system, such as air maintenance devices, air compressors, accelerators, electric alarm switches, mechanical sprinkler alarms, etc., aredescribedindetailintheindividualbulletinsfor these products. All valves are listed and approved by Under- writers Laboratories, Inc. and Factory Mutual Research Corp. only when used with the valve manufacturers trim sets. 3. Figure 3 Figure 4—Model D Dry Pipe Valve Model D Basic Trimming U.S. Groove Dimensions in Inches Valve Size Outlet Dia. Groove Dia. Groove Width Outlet Face to Groove 4 6 4.500 6.625 4.334 6.455 38 38 58 58 Flanged Inlet and Outlet Flanged Inlet and Grooved Outlet 4 (100 mm) 120 lb. (54.5 kg) 6 (150 mm) 242 lb. (109.5 kg) 110 lb. (49.83 kg) 228 lb. (103.28 kg) Metric Flange Dimensions in Millimeters Valve Size Bolt Circle Dia. Bolt Hole Dia. Flange Outside Dia. Flange Thickness Number Bolts 100 150 180 241 18.3 22.2 229 279 23.8 25.4 8 8 Valve Size Size Equiv. Length 4 (100 mm) 28ft (8.51 m) 6 (150 mm) 47ft (14.29 m) The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by PG. Printed in U.S 10/06 P/N 9999970045 •Style of Trim - Loose Individual part trim or seg- mentally assembled trim or factory trimmed valve. •Additional Equipment—Air Maintenance De- vices, Air Compressors, Accelerators, Electric Sprinkler Alarm Switches and Mechanical Sprinkler Alarms must be separately ordered. Ordering Information Specify •Valve Size: Either 4 (100 mm) or 6 (150 mm). When size is specified in mm, a metric valve per 3(c) will be supplied. •Inlet and Outlet Connection — Either Flanged/Flanged or Flanged/Grooved. •Trim - Basic Trim Priming Chamber Attachment Fill Line Attachment •Galvanized or Black Trim. Installation Dimensions of 4 (100mm) & 6 (150mm) sizes Revisionlinesindicateupdatedornewdata. The Reliable Automatic Sprinkler Co., Inc. 800.431.1588 Sales Office 800.848.6051 Sales Fax 914.829-2042 Corporate Office www.reliablesprinkler.com Internet Address Recycled Paper Installation Measurement in Inches ValveABCDEFGH I J 4 (100mm)16 6 12 517101115412 212 312 6 (150mm)19 8 38 658 185 8 115 8 11 15 78 412 312 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 807 Rev. JBulletin 807 Rev. J Model G Swing Check Valves 2½” (65 mm), 76 mm 3” (80 mm), 4” (100 mm), 6” (150 mm), 165 mm & 8” (200 mm) Features1. Grooved end connections.2. Compact, lightweight design.3. Non–slamming, spring loaded clapper to minimize water hammer.4. Approved for horizontal and vertical instal-lation.5. Streamlined body design provides very low friction loss.6. Elastomer faced clapper provides leak–free, non–sticking sealing. General Reliable Model G Swing Check Valves are multiple pur- pose valves performing regular check valve duties with very low friction loss. All four sizes are approved for use in fire protection systems. Typical applications include con- nections between public water supplies and private fire systems, at the discharge from fire pumps, at gravity tank connections and at fire department pumper connections. All Model G Check Valves are provided with a ½” NPT (R½) supply side connection (Item 12, Fig.2). Grooved end connections provide fast and easy in- stallation using listed or approved mechanical grooved couplings. Rigid style grooved couplings can be used for positive clamping to resist flexural and tor- sional loads. Swing Check Valves and associ- ated equipment should periodically be given a thorough inspection and test. NFPA 25 provides minimum maintenance requirements. Check valves should be inspected and operated at least annu- ally. Parts should be replaced as required. When Model G Swing Check Valves are installed verti- cally, the direction of the flow arrow must point upward. For horizontal installations, the hinge pin must be located at the top. Figure 1 Valve Description 1. Rated working pressure 250 psi (17,25 bar). 2. Factory hydrostatic test pressure 500 psi (34,5 bar). 3. Friction loss, expressed in equivalent length of Sch. 40 pipe with C = 120 (based on Hazen and Williams formula): 2½” (65 mm) & 76 mm - 7 ft (2.13 m) 3” (80 mm) - 7 ft (2.13 m) 4” (100 mm) - 10 ft (3.05 m) 6” (150 mm) & 165 mm - 16 ft (4.88 m) 8” (200 mm) - 15.9 ft (4.85 m) 4. Standard grooved end dimensions per ANSI/AWWA C606. Technical Data Valve Size Face–to–Face Dimensions Shipping weight 2½” (65 mm) & 76 mm 7.12” (181 mm) 9 lbs. (4kg) 3” (80 mm) 7.62” (193 mm) 11 lbs. (5kg) 4” (100 mm) 8.44” (214 mm) 17 lbs. (7.7kg) 6” (150 mm) & 165 mm 10.25” (260 mm) 38 lbs. (17.25kg) 8” (200 mm) 12.5” (318 mm) 63 lbs. (28.58kg) Ϯ Ϯ͘ϱ ϯ ϯ͘ϱ ϰ ϰ͘ϱ ϱ ƌĞƌŽƉ͕W^/;ďĂƌͿWƌĞƐƐƵƌĞƌŽƉǀƐ͘&ůŽǁZĂƚĞ DŽĚĞů'^ǁŝŶŐŚĞĐŬsĂůǀĞƐ ;Ϭ͕ϯϰͿ ;Ϭ͕ϯϭͿ ;Ϭ͕ϮϴͿ ;Ϭ͕ϮϰͿ ;Ϭ͕ϮϭͿ ;Ϭ͕ϭϳͿ ;ϬϭϰͿ Ϭ Ϭ͘ϱ ϭ ϭ͘ϱ Ϭ ϱϬϬ ϭϬϬϬ ϭϱϬϬ ϮϬϬϬ ϮϱϬϬ ϯϬϬϬ ϯϱϬϬ ϰϬϬϬ ϰϱϬϬ ϱϬϬϬWƌĞƐƐƵƌ &ůŽǁZĂƚĞ͕'WD;>ͬŵŝŶͿ ;Ϭ͕ϭϰͿ ;Ϭ͕ϭϬͿ ;Ϭ͕ϬϳͿ ;Ϭ͕ϬϯϰͿ ;ϭϴϵϯͿ ;ϯϳϴϱͿ ;ϱϲϳϴͿ;ϳϱϳϭͿ ;ϵϰϲϰͿ ;ϭϭϯϱϲͿ ;ϭϯϮϰϵͿ ;ϭϱϭϰϮͿ ;ϭϳϬϯϰͿ ;ϭϴϵϮϳͿ ϴϬϳ,Zd Approvals 1. Listed by Underwriters Laboratories, Inc. 2. Underwriters’ Laboratories certified for Canada. 3. Approved by Factory Mutual Research Corp.* 4. NYC MEA 258-93-E * FM Approved as both a “Single” check valve and as an “Anti-Water Hammer” check valve. Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by RecycledPaper Revision lines indicate updated or new data. EG. Printed in U.S.A. 12/14 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. P/N 9999970071 Valve Disassembly 1. Close the main water supply valve and drain the system. 2. Remove the check valve from the piping system. 3. Inspect the Seat (2) for any cuts, scrapes and dents. Replace the valve if any damage is found. 4. To replace the Facing Seal (4), remove the Clapper (3), unscrew the Locknut (10) and remove the Reten- tion Bolt (9). Valve Reassembly 1. Thoroughly clean the Clapper (3). Insert the Retention Bolt (9) with a new Gasket (6). 2. Place the new Facing Seal (4) and the Clamping Ring (5) against the Clapper (3). Tighten the new Locknut (10) to 21 in.-lbs. (2.37 N•m) torque in 2½” (65 mm), 76 mm & 3” (80 mm) sizes and to 52 in.-lbs. (5.87 N•m) in 4” (100 mm), 6” (150 mm), 165 mm & 8” (200 mm) sizes. 3. Insert the clapper assembly into the valve through the downstream opening. Reinsert the Hinge Pin (8) while holding the coils of the properly oriented Spring (7) in place. Install the hinge pin Plug (11). 4. Reinstall the check valve in the system. 5. Place the system back in service. Ordering Information Specify: 1. Model G Right–Check™ Valve. 2. Size. Contact the installing contractor or Reliable if any difficulties are expe- rienced. Should replacement parts be needed, use only genuine Reli- able parts. Refer to figure 2. Item No.Part Name Material Qty. Part Number 2½” (65 mm)76 mm 3” (80 mm) 4” (100 mm) 6” (150 mm) 165 mm 8” (200 mm) 1* Valve Body Gray Iron, ASTM–A48 Class 30A 1 91005012 91005011 91005013 91005014 91005016 91006015 91005008 2* Seat Bronze C83600 or C93200, ASTM–B505 1 96020200 96020200 96020300 96020400 96020600 96020600 96020800 3 Clapper Stainless Steel 304, ASTM–A240 1 91816112 91816112 91816113 91816114 91816116 91816116 91816118 4 Facing Seal ** EPDM Rubber 1 95520200 95520200 95520300 95520400 95520600 95520600 95520800 5 Clamping Ring Stainless Steel 304, ASTM–A240 1 95290300 95290300 95290300 95290400 95290600 95290600 95290800 6 Gasket ** EPDM Rubber 1 93720604 93720604 93720604 93720604 93720604 93720604 93720804 7 Spring Stainless Steel 302, ASTM–A313 1 96400300 96400300 96400300 96400400 96400600 96400600 96400800 8 Hinge Pin Stainless Steel 303, ASTM–A582 1 95000280 95000280 95000300 95006824 95000600 95000600 95000800 9 Bolt Stainless Steel 304, ASTM–F593 1 91090600 91090600 91090600 91090600 91090600 91090600 91090800 10 Locknut ** Stainless Steel 303, ASTM–F594 1 94913816 94913816 94913816 94913816 94913816 94913816 94913816 11 Plug, ¼” NPT Steel 1 95201800 95201800 95201800 95201800 95201800 95201800 95201800 12 Plug, ½” NPT Steel 1 98604402 98604402 98604402 98604402 98604402 98604402 98604402 13 Shoulder Eye Steel 1 N/A N/A N/A N/A N/A N/A 98020016 ** Replacement Seal Kit 1 6888040025 6888040025 6888040030 6888040040 6888040060 6888040060 6888040080 * Not field replaceable. Figure 2 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 206 Rev. PBulletin 206 Rev. P Ball Drip Sight Drain Drum Drip Control Valve Seal Fill Cup Inspectors Test Connections Pressure Gauges Model C — Automatic Ball Drip An automatic drain valve horizontally installed at the low point in the fire department connection piping of automatic sprinkler systems. Water pressure from a fire department pumper au- tomatically closes this valve. It automatically re–opens when pressure ceases, permitting this piping to drain and thereby preventing freezing. Made of bronze and available with 3/4” (R3/4 ) or 1/2” NPT (R1/2) female inlet connection. FM approved. Length: 29/16”. Maximum working pressure: 175psi (12bar). Model C - Mechanical Ball Drip Valve The Model C Mechanical Ball Drip Valve is a listed trim com- ponent used in the alarm line of Reliable Model A & D dry valves, Model DDX deluge and DDX preaction valves. The mechanical ball drip valve is designed to close upon activa- tion of the dry or deluge valve when sufficient flow is pres- ent in the alarm line. In the normal or open position the me- chanical ball drip allows for the relieving of pressure in the alarm chamber of the valve. After valve activation, push in the plunger of the mechanical ball drip valve to manually release the water pressure and to drain the alarm line of the valve. Made of bronze and available with ½” NPT (R½) female inlet connection. FM approved. Length: 3½”. Maximum working pressure: 175 psi (12 bar). Model C — 2” (50 mm) Sight Drain Designed for installation in drain lines of sprinkler systems that connect with closed drains. Made of cast iron with clear plastic tube. Has 2” NPT (50mm) female pipe connection. Length: 6” (152mm). Model B — Drum Drip Permits draining the low points of dry pipe systems without tripping the system. Made of cast iron with 3/4” NPT (R¾) fe- male pipe connection at each end. Diameter: 61/2” (165mm). Length: 73/4” (197mm). Model A — Control Valve Seal Made of tin–plated steel. Two piece, snap type construction. Outer piece holes are sized for use with standard sealing wire (wire not included). Diameter: 7/8” (22mm). Model A — Fill Cup Made of cast iron. Available with 1/2” or 3/4” NPT (R1/2 or R3/4) female pipe connection. Cup Diameter: 33/4” (95mm). Length: 21/4” (57mm). The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices(800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A 08/11 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. P/N 9999970037 Inspectors Test Connections Installed in the test line of sprinkler systems to test alarms by simulating the flow of water through a sprinkler. • Model A — Blind Test Connection Designed for installation in test lines of sprinkler systems that connect to open drains. Made of bronze with 1” NPT female pipe connections. Orifice gives flow equivalent to one nomi- nal 1/2” (15mm) orifice sprinkler. Length: 17/8” (48mm). Maximum working pressure: 175psi (12bar). • Model B — Sight Test Connection Designed for installation on the drain side of the test valve in a test line that connects to a closed drain. Made of cast iron with clear tube. Smooth bore non–corrosive orifice gives flow equivalent to one nominal 1/2” (15mm) orifice sprinkler. Has 1” NPT pipe connections. Length: 51/16” (129mm). • Model UA — Water Pressure Gauge Range 0 to 300psi in 5psi increments, and 0 to 2000 kPa in 50kPa increments. 1/4” NPT (R1/4) male pipe connection. Case: 31/2” diameter (89mm). Height: 43/4” (121mm). Also available (not shown) with a range of 0 to 600psi (4000kPa) with 10psi (100kPa) increments. Accuracy: ANSI B40.1 Grade B (3–2–3%) Underwriters Laboratories Listed Factory Mutual Approved • Model UA — Air Pressure Gauge Range 0 to 80psi in 1psi increments, and 0 to 550kPa in 10kPa increments. Retard to 250psi and 1750kPa. 1/4” NPT (R1/4) male pipe connection. Case: 31/2” diameter (89mm). Height: 43/4” (121mm). Accuracy: ANSI B40.1 Grade B (3–2–3%) Underwriters Laboratories Listed Factory Mutual Approved • Low Air Pressure Diaphragm Gauge Range 0 to 60 oz. in 1 oz. increments, and 1/4” NPT (R 1/4) male pipe connection. Case: 1/2” diameter (63.5mm). Height: 31/2” (88.9mm). MODEL DD-1 CONDENSATE DRAIN WiliagTM Condensate Drain FEATURES & BENEFITS Ready to Install No Fabrication Required Eliminates Searching for Materials 175 psi Rated 24 Hour Ice Build-up Test with No Damage 600 psi Pressure Tested GENERAL DESCRIPTION The DD-1 Condensate Drain is a Pre-manufac- tured drum drip for installation in Dry Pipe, Deluge and Preaction Automatic Sprinkler Systems. The DD-1 Condensate Drain body is made from Electric-Resistance-Welded Carbon and Alloy Steel Mechanical Tubing. Other drains are usually constructed from various parts that must be assembled at the time of installation. There is no comparison in the quality and look of the DD-1 Condensate Drain, and it is quick and easy to install. TECHNICAL DATA Volume: 0.1875 gallons Standard working pressure: 175 psi Length:24" (615 mm) Turning radius:2.5" (64 mm) Shipping weight:6.25 lbs. Patent:U.S.A. No. 6,102,066 Valve type and manufacturer may vary. Contact a TFBP distributor for a complete description of all Listing criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. TYCO is a registered trademark of Tyco International Services GmbH, and is used under license by Tyco Fire & Building Products and its affiliates in the United States and other countries. Contact a TFBP distributor for a complete description of all Listing criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. Tyco Fire & Building Products Technical Services Phone:800-381-9312 Fax: 800-791-5500 www.Tyco-Fire.com Wiliag is a trademark of The Wiliag Company. All other brand names, product names or trademarks belong to their respective owners. Tyco Fire & Building Products reserves the right to change product design and specifications without notice. Copyright © 2007 Tyco Fire Products LP. All rights reserved. Printed in USA / VIG / 5M / TF-2007026 04/07 MODEL DD-1 ORDERING PROCEDURE & SPECIFICATIONS MODEL-DD1 CONDENSATE DRAIN Part Number: 52-380-1-001 2.50" Radius 24.0" 1" Shut Off Valve 1" Plug 1" Shut Off Valve Example of a field generated drum drip with multiple fittings and pipe nipples. NOTE: the example shows seven make-ups. THE CONDENSATE DRAIN INCLUDES: One condensate barrel Two – 1" shut off valves (valve manufacturer may vary) One – 1" plug Sizes: 1/4" – 4" (8 – 100mm) Series FBV-3C 2-piece, full port, brass ball valves are used in com-mercial and industrial applications for a full range of liquids and gases. They feature a bottom-loaded blowout proof stem, virgin PTFE seats, thrust washer, and adjustable stem packing gland, stem packing nut, chrome plated brass ball, brass adapter, and steel handle. Features • Certified to NSF/ANSI standard 61/8 • CSA approved threaded valves only 1/4" – 3" (15 – 80mm) • UL/FM approved threaded valves 1/2" – 2" (15 – 50mm) • UL Listed solder valves 1/2" – 2" (15 – 50mm) • Fluorocarbon elastomer stem O-ring prevents stem leaks • Adjustable stem packing gland • PTFE stem packing seal, thrust washer, and seats • Bottom loaded blowout proof stem • Machined chrome plated brass ball • Valves comply to MSS-SP-110 standard Models FBV-3C: 1/4" – 4" (8 – 100mm) with threaded connections FBVS-3C: 1/2" – 3" (15 – 80mm) with solder connections FBV-3C-TH: 1/2" – 1" (15 – 25mm) tee handle with threaded connec-tions FBVS-3C-TH: 1/2" – 1" (15 – 25mm) tee handle with solder connections Pressure – Temperature Temperature Range: -40ºF to 400ºF (-40ºC to 204ºC) Pressure Ratings FBV-3C : 1/4" – 2" (8 – 50mm) 600psi (41 bar) WOG, non-shock 150psi (10.3 bar) WSP 2 1/2" – 4" (65 – 100mm) 400psi (27.5 bar) WOG, non-shock 125psi (8.6 bar) WSP FBVS-3C : 1/2" – 2" (15 – 50mm) 600psi (41 bar) WOG, non-shock 150psi (10.3 bar) WSP 21/2" – 3" (65 – 80mm) 400psi (27.5 bar) WOG, non-shock 125psi (8.6 bar) WSP *This valve is designed to be soft soldered into lines without disassembly, using a low temperature solder to 420°F (216°C). Higher temperature solders may damage the seat material. NOTE: Apply heat with the flame directed AWAY from the center of the valve body. Excessive heat can harm the seats. After soldering, the packing nut may have to be tightened. Approvals 1/4" – 3" (8 - 80mm) FBV-3C 1/2" – 1" (15 - 25mm) FBV-3C-TH Certified to NSF/ANSI standard 61/8* 1/2" – 3" (15 – 80mm) FBVS-3C 1/2" – 1" (15 – 25mm) FBVS-3C-TH Certified to NSF/ANSI standard 61/8* *Domestic cold water at 73ºF (23ºC) 1/2" – 2" (15 – 50mm) FBV-3C UL/FM approved 1/2" – 1" (15 – 25mm) FBVL-3C-TH 1/2" – 2" (15 – 50mm) FBVS-3C UL Listed 1/2" – 1" (15 – 25mm) FBVS-3C-TH Gas Approvals (Threaded Valves Only) 1/4" – 3/8" (8 – 10mm) ASME B16.33, CSA 1/2 psig, 5psig, (14, 34 kPa) @ -40ºF to 125ºF (-40ºC to 52ºC) 1/2" – 2" (15 – 50mm) ASME B16.33, CSA 1/2 psig, 5psig, and 125psig (14, 34 and 862 kPa) @ -40ºF to 125ºF (-40ºC to 52ºC) 21/2" – 3" (65 – 80mm) ASME B16.38, CSA 1/2 psig, 5psig, and 125psig (14, 34 and 862 kPa) @ -40ºF to 125ºF (-40ºC to 52ºC) Specifications Approved valves shall be 2-piece full port design constructed of a forged brass body and end adapter. Seats and stem packing shall be virgin PTFE. Stem shall be bottom loaded, blowout proof design with fluo-rocarbon elastomer O-ring to prevent stem leaks. Valve shall have chrome plated brass ball and adjustable packing gland. Threaded valves 1/2" – 3" (shall be CSA approved to 1/2, 5, and 125psig (14, 34 and 862 kPa), UL/ FM approved and certified to NSF/ANSI standard 61/8. Solder valves to be UL listed and certified to NSF/ANSI standard 61/8. Valve sizes 1/4" – 2" (8 – 80mm) shall be rated to 600psi (41 bar) WOG non-shock and 150psi (10.3 bar) WSP. Valve sizes 21/2" – 4" (65 – 100mm) threaded, shall be rated to 400psi (27.5 bar) WOG non-shock and 125psi (8.6 bar) WSP. Valve sizes 21/2" – 3" (65 – 88mm) solder shall be rated to 400psi (27.5 bar) WOG non-shock and 125psi (8.6 bar) WSP. Valve shall be a Watts Regulator Company Series FBV-3C (threaded) or FBVS-3C (solder). For Commercial and Industrial Applications ES-FBV-3C Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location ––––––––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative –––––––––––––––––––––––––––––––––––––––– FBV-3C FBVS-3C*FBV-3C-TH Series FBV-3C, FBVS-3C approved Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. 2-Piece, Full Port, Brass Ball Valves Dimensions – Weights Materials Temperature – Pressure FBV-3C-TH and FBVS-3C-TH FBV-3C FBV-3C-TH FBVS-3C-THFBVS-3C H1 C L1 I H C L I H1 C L1 I H C L I 1/2" - 1" Size (DN) DimeNSioNS WeigHT C H H1 I L L1 in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg. 1⁄4 8 113⁄16 46 37⁄16 87 - - 1⁄2 12.9 13⁄4 45 - - 0.4 0.2 3⁄8 10 113⁄16 46 37⁄16 87 - - 1⁄2 12.9 13⁄4 45 - - 0.4 0.2 1⁄2 15 113⁄16 46 37⁄16 87 37⁄16 87 1⁄2 12.9 115⁄16 50 21⁄16 52 0.4 0.2 3⁄4 20 21⁄4 57 4 101 4 101 3⁄4 19.2 25⁄16 59 211⁄16 68 0.8 0.3 1 25 25⁄8 67 41⁄4 108 41⁄4 108 1 25.5 213⁄16 72 31⁄4 83 1.2 0.5 11⁄4 32 213⁄16 71 41⁄4 108 41⁄4 108 11⁄4 31.9 33⁄16 81 311⁄16 94 1.8 0.8 11⁄2 40 33⁄16 80 51⁄4 134 55⁄16 135 11⁄4 38.0 31⁄2 88 41⁄4 108 2.6 1.2 2 50 31⁄2 89 6 153 6 153 2 50.9 41⁄8 105 55⁄16 135 3.7 1.7 21⁄2 65 41⁄16 104 73⁄8 187 73⁄8 188 21⁄2 63.6 55⁄16 134 61⁄4 158 7.1 3.2 3 80 41⁄2 114 73⁄4 197 73⁄4 197 3 76.3 61⁄16 154 73⁄8 185 11.3 4.7 4 100 53⁄8 136 95⁄8 245 - - 4 101.6 77⁄16 189 - - 17.7 8.0 A. Handle Nut Zinc plated carbon steel B. Handle Assembly Zinc plated carbon steel with vinyl insulator C. Packing Nut Brass D. Stem Packing Virgin PTFE E. O-ring Fluorocarbon elastomer (FKM) F. Thrust Washer Virgin PTFE G. Stem Machined Brass H. Tag Cardboard, Mylar coated both sides I. Body Forged Brass J. Seats Virgin PTFE K. Ball Chrome plated brass L. Adapter Forged Brass ES-FBV-3C 0935 © 2009 Watts USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca A Watts Water Technologies Company A B C D E F G H I J K J L A H EF G B CD I J J L K FBV-3C FBV-3C-TH A H E FG B C D I J J L K Size (DN) DimeNSioNS WeigHT C H H1 I L L1 in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg. 1⁄2 15 19⁄16 39.6 31⁄8 79.3 31⁄8 79.3 1⁄2 12.9 115⁄16 50 21⁄16 52 0.4 0.2 3⁄4 20 2 50.9 33⁄8 85.7 33⁄8 85.7 3⁄4 19.2 25⁄16 59 211⁄16 68 0.8 0.3 1 25 21⁄8 53.9 33⁄8 85.7 33⁄8 85.7 1 25.5 213⁄16 72 31⁄4 83 1.2 0.5 H I C L H1 I C L