Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
223300-1.0 - Electric Water Heater-PD REVIEWED AND APPROVED
Submittal Transmittal SUBMITTAL TRANSMITTAL Project Name: Ithaca Arthaus Project Number : 18260 A Transmittal (from SUBCONTRACTOR) To:Vecino Construction, LLC Date Submitted 6/30/2020 Attn:Corey Olmstead Submittal No. (per Procore)223300 1,2,3 corey@vecinogroup.com x Submitted for Review & Approval REV (0) Phone: (315) 854-0979 ReSubmitted for Review & Approval REV (1) From:Woodcock & Armani mike.meyer@comfortsystemsusa.com This is a FULL SUBMITTAL 315-701-2042 This is a PARTIAL Submittal Item No. Dwg. And/or Specification Section SpecParagraph / No.Title / Description Manufacturer Submittal Type Lead Time 1 223300 1.1B1 Electric Domestic Water Heaters product data Bradford White 2 223300 1.1B2 Electric Domestic Water Heaters documentation Bradford White 3 223300 1.1B3 Electric Domestic Water Heaters labeling Bradford White 4 223300 1.1C Electric Domestic Water Heaters warranty Bradford White 5 6 7 8 9 10 11 Comments:Vecino Construction Stamp BW A&E Stamp Signature/Stamp of Transmitter Date ElectriFLEX HD™ (Heavy Duty) Commercial Electric Water Heater Bradford White ElectriFLEX HD™ Electric Models Feature: Immersion Thermostats —Designed to provide outlet water at a thermostatically controlled temperature greater than 180°F (82°C). Conversion Kits—Design certified by ETL for field conversion. Conversion kits are available to convert any one model to a variety of voltages and kW inputs (Kit part numbers on reverse side). All models are shipped from the factory standard Three Phase, and can be field converted to Single Phase without a conversion kit. Insulation System—3" (76mm) Non-CFC foam covers the sides and top of the tank, reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity. Factory Installed Hydrojet® Sediment Reduction System—Sediment reducing device that also increases first hour delivery of hot water while minimizing temperature build-up in tank. Vitraglas® Lining—An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a temperature of over 1600°F (871°C). Water Connections—11⁄2" (38mm) NPT factory-installed true dielectric fittings extend water heater life and simplify water line connections. Elements—Screw in style low watt density incoloy sheathed elements standard. These elements resist burnout caused by dry fire or lime buildup. Two Protective Magnesium Anode Rods—Provide added protection against corrosion for long-term, trouble-free service. Hand Hole Cleanout—Allows inspection of tank interior and facilitates the removal of sediment deposits. ASME Construction Available. NSF Construction Available. Low Restrictive Brass Drain Valve—Durable tamper proof design. T&P Relief Valve—Installed. Completely Pre-wired—With pressure lug terminal block eliminating need for splicing or taping of wires. Voltages Available—208v, 240v, 277v, 380v, 415v, 480v and 600v. Internal Fusing—Standard on all models. Photo is of CEHD50(kW)3*CF 3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.comFor products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation. 1401-A-1219 ElectriFLEX HD™ Electric Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed ModelNumber FFloor toT&PConn. in. BJacketDia. in. AFloor toTop ofHeater in.U.S.Gal. NominalGal.Capacity CEHD50(A)(kW)3*CF CEHD80(A)(kW)3*CF CEHD120(A)(kW)3*CF 50 80 119 Imp.Gal.Std.ASME 42 67 100 302 378 485 507/16 611/4 6411/16 GFloor toTop ofControlBoxin. 491/8 491/8 505/8 12 13 151/8 24 26 301/4 4011/16 523/16 543/4 525/8 651/2 663/4 DFloor toHot WaterConn. in. ModelNumber FFloor toT&PConn. mm. BJacketDia. mm. AFloor toTop ofHeater mm.LitersStd.ASME NominalLiterCapacity CEHD50(A)(kW)3*CF CEHD80(A)(kW)3*CF CEHD120(A)(kW)3*CF 189 303 450 137 171 220 ApproxShippingWeightlbs. 270 335 430 ApproxShippingWeightkg. 122 152 195 1281 1556 1643 Min. - Max.kWInputRange 13.5 - 54 6 - 54 6 - 54 Min. - Max.kWInputRange 13.5 - 54 6 - 54 6 - 54 GFloor toTop ofControlBoxmm. 1248 1248 1337 308 330 384 WaterConn.NPT in. 11/2 11/2 11/2 WaterConn.NPT mm. 38 38 38 610 660 768 1033 1326 1391 1337 1664 1695 DFloor toHot WaterConn. mm. JC/L ofHot WaterConn.in. JC/L ofHot WaterConn.mm. JC/L ofHot WaterConn. in. JC/L ofHot WaterConn. mm. 525/8 651/2 663/4 CFloor toHot WaterConn. in. 1337 1664 1695 CFloor toHot WaterConn. mm. 615/16 7 615/16 EFloor toC/L ofCold WaterConn.in. 176 178 176 EFloor toC/L ofCold WaterConn.mm. Commercial Electric Water Heater * = voltage and phase designator. Voltage and phase must be specified when ordering. Example: CEHD50243*CF, 240 Volt, 3 phase. (A) ASME Construction available. For ASME construction add “A” to the model number. Example: CEHD50A243*CF. CEHD50(A) - Not available in 12kW or less. G E F A B C 45° 15 1/8" 22 1/8"19 1/2" 52° 13" 56° 47° COLD COLD COLD 58° 12" 18 1/2" 63° J J J HOT HOT HOTJJJ CEHD50(A)CEHD80(A)CEHD120(A) Commercial Electric Water Heater RecoveryGPH Temperature Rise °FInputkW 6 9 12 13.5 15 18 24 27 30 36 45 54 40 62 93 124 140 155 186 248 279 310 372 465 558 50 50 74 99 112 124 149 199 223 248 298 372 447 60 41 62 83 93 103 124 164 186 207 248 310 372 70 35 53 71 80 89 106 142 160 177 213 266 319 80 31 47 62 70 78 93 124 140 155 186 233 279 90 28 42 55 62 69 83 110 124 138 165 207 248 100 25 37 50 56 62 74 99 112 124 149 186 223 120 21 31 41 47 52 62 83 93 103 124 155 186 140 18 27 35 40 44 53 71 80 89 106 133 160 RecoveryLPH Temperature Rise °CInputkW 6 9 12 13.5 15 18 24 27 30 36 45 54 23 235 352 469 530 587 704 939 1056 1173 1408 1760 2112 28 189 280 375 424 469 564 753 844 939 1128 1408 1692 34 155 235 314 352 390 469 621 704 784 939 1173 1408 40 132 201 269 303 337 401 538 606 670 806 1007 1208 45 117 178 235 265 295 352 469 530 587 704 882 1056 50 106 159 208 235 261 314 416 469 522 625 784 939 56 95 140 189 212 235 280 375 424 469 564 704 844 67 79 117 155 178 197 235 314 352 390 469 587 704 78 68 102 132 151 167 201 269 303 337 401 503 606 208VPhase Number of Elements 13 3 3 3 3 3 3 6 6 6 6 9 9 3 3 3 3 3 3 6 6 6 6 9 9 240VPhase 13 3 3 3 3 3 3 6 6 6 6 9 9 3 3 3 3 3 3 6 6 6 6 9 9 480VPhase 13 3 3 3 3 3 3 6 6 6 6 9 9 3 3 3 3 3 3 6 6 6 6 9 9 277VPhase 1 3 3 3 3 3 3 6 6 6 6 9 9 380VPhase 3 3 3 3 3 3 3 6 6 6 6 9 9 415VPhase 3 3 3 3 3 3 3 6 6 6 6 9 9 600VPhase 3 3 3 3 3 3 3 6 6 6 6 9 9 InputkW 6 9 12 13.5 15 18 24 27 30 36 45 54 From *** Converting 6 or 9 element configurations (24-54kW) 208/240/480 Volt 277/380/415 Volt 208/240/480 Volt 277/380/415 Volt To 277/380/415 Volt 208/240/480 Volt 208/240/480 Volt 277/380/415 Volt Transformer Required 264-41995-02 264-41995-01 No Transformer Change Required No Transformer Change Required From *** Converting 3 Element Configurations (6-18kW) 208/240/480 Volt 277/380/415 Volt 208/240/480 Volt 277/380/415 Volt To 277/380/415 Volt 208/240/480 Volt 208/240/480 Volt 277/380/415 Volt Transformer Required 264-41994-02 264-41994-01 No Transformer Change Required No Transformer Change Required 415-51043-73 415-51043-74 415-51043-128 415-51043-129 415-51043-130 415-51043-131 415-51043-132 415-51043-133 415-51043-134 415-51043-135 415-51043-136 415-51043-137** † † † † † † † † † † † † † † † † † † † † † 2 3 4 4.5 5 6 4 4.5 5 6 5 6 6 9 12 13.5 15 18 24 27 30 36 45 54 CEHD with 3 Elements CEHD with 6 Elements CEHD with 9 Elements 415-51043-61 415-51043-62 415-51043-63 415-51043-64 415-51043-122 415-51043-123 415-51043-67 415-51043-68 415-51043-124 415-51043-125 415-51043-126 415-51043-127 415-51043-49 415-51043-50 415-51043-51 415-51043-114 415-51043-115 415-51043-116 415-51043-55 415-51043-117 415-51043-118 415-51043-119 415-51043-120 415-51043-121 415-51043-37 415-51043-38 415-51043-104 415-51043-105 415-51043-106 415-51043-107 415-51043-108 415-51043-109 415-51043-110 415-51043-111 415-51043-112 415-51043-113 415-51043-25 415-51043-26 415-51043-94 415-51043-95 415-51043-96 415-51043-97 415-51043-98 415-51043-99 415-51043-100 415-51043-101 415-51043-110 415-51043-103 415-51043-85 415-51043-14 415-51043-15 415-51043-86 415-51043-87 415-51043-88 415-51043-19 415-51043-89 415-51043-90 415-51043-91 415-51043-92 415-51043-93 415-51043-01 415-51043-02 415-51043-03 415-51043-04 415-51043-05 415-51043-06 415-51043-07 415-51043-08 415-51043-09 415-51043-10 415-51043-11 415-51043-12 Model Conversion Kit Part Numbers***Desired Input 208 VoltsTotalkW ElementkW 240 Volts 277 Volts 380 Volts 415 Volts 480 Volts 600 Volts* 208VPhase Full Load Current Amperes 13 28.8 43.2 57.6 64.9 72.1 86.5 115.4 129.8 144.2 173.0 216.3 259.6 16.6 25.0 33.3 37.5 41.6 50.0 66.7 75.0 83.3 100.0 125.0 150.0 240VPhase 13 25.0 37.2 50.0 56.2 62.5 72.0 100.0 112.5 125.0 150.0 187.5 225.0 14.4 21.6 28.9 32.5 36.1 43.4 57.8 65.0 72.2 86.7 108.3 130.0 480VPhase 13 12.5 18.7 25.0 28.1 31.2 37.5 50.0 56.2 62.5 75.0 93.7 112.5 7.2 10.8 14.4 16.2 18.0 21.6 28.9 32.5 36.1 43.3 54.1 65.0 277VPhase 1 21.6 32.4 43.3 48.7 54.1 64.0 86.6 97.4 108.3 129.9 162.4 194.9 380VPhase 3 10.0 14.0 19.0 21.0 23.0 28.0 37.0 41.0 46.0 55.0 69.0 83.0 415VPhase 3 9.0 13.0 17.0 19.0 21.0 25.0 34.0 38.0 42.0 50.0 63.0 75.0 600VPhase 3 5.8 8.7 11.5 13.0 14.4 17.3 23.1 26.0 28.9 34.6 43.3 52.0 InputkW 6 9 12 13.5 15 18 24 27 30 36 45 54 3 element models may convert 6 kW thru 18 kW ONLY 6 element models may convert 24 kW thru 36 kW ONLY 9 element models may convert 45 kW thru 54 kW ONLY * Only kW conversion is allowed for models rated 600V. Models rated 480V and below must not be converted to 600V. ** Only available as a three phase conversion kit. † CEHD50(A) - Not available in 12kW or less. 3 element models may convert 6 kW thru 18 kW ONLY 6 element models may convert 24 kW thru 36 kW ONLY 9 element models may convert 45 kW thru 54 kW ONLY ©2019, Bradford White Corporation. All rights reserved. For field service, contact your professional installer or local Bradford White sales representative. Sales 800-523-2931 n Fax 215-641-1612 Technical Support 800-334-3393 n Email techserv@bradfordwhite.com Warranty 800-531-2111 n Email warranty@bradfordwhite.com International: Telephone 1-215-641-9400 n Email international@bradfordwhite.com / www.bradfordwhite.com Ambler, PA Sample Specification The water heater shall be a Bradford White ElectriFLEX HD™ model with a rated storage capacity of not less than_______gallons (_______liters), a minimum kW input of _______kW (_______ BTU/Hr.), a minimum recovery of _______GPH (_______ LPH). The tank shall be Vitraglas® lined and have a bolted hand hole cleanout.The tank shall have _______magnesium anode rods installed in separate tank head couplings. The heater shall have 3" Non-CFC foam insulation, and come equipped with an ASME rated T&P relief valve, a cold water inlet Hydrojet® Sediment Reduction System. It shall be design certified by ETL for 180ºF (82ºC) application, either with or without a separate storage tank, and comply with state and local codes and ordinances. General All electric water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All models are design certified by ETL, to provide outlet water at a thermostatically controlled temperature greater than 180°F (82°C) as an Automatic Storage Heater, and an Automatic Circulating Tank Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180°F (82°C) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Printed in U.S.A.1401-A-1219 P/N 238-36612-00X (07/16) BRADFORD WHITE CORPORATION WHAT DOES THIS LIMITED WARRANTY COVER? This limited warranty covers both the glass-lined tank and component parts for leakage or other malfunction caused by defects in materials and/or workmanship. It extends to the first buyer and to any subsequent owner(s) as long as the water heater remains installed at its original place of installation. WHAT DOES THIS LIMITED WARRANTY NOT COVER? 1. This limited warranty does not cover leakage or other malfunction caused by: a) Defective installation, and specifically, any installation which is made: i) in violation of applicable state or local plumbing, housing or building codes, or ii) without a certified American Gas Association, ASME, or comparable combination temperature and pressure relief valve, or iii) contrary to the written instructions furnished with the unit. b) Adverse local conditions, and specifically, sediment or lime precipitate in the tank or corrosive elements in the atmosphere. c) Misuse, and specifically, operations, and maintenance contrary to the written instructions furnished with the unit, removal of anode(s), disconnection, alteration or addition of non- approved components or apparatus, operation with fuels or at settings other than those set forth on the rating plate, or accidental or other exterior damage. 2. This warranty also does not cover: a) Production of noise, taste, odors, discoloration or rusty water. b) Incidental property damage, loss of use, inconvenience or other incidental or consequential costs. c) Costs associated with the replacement and/or repair of the unit, including: i) any freight, shipping or delivery charges ii) any removal, installation or re-installation charges iii) any material, and/or permits required for installation, re-installation or repair iv) charges to return the defective water heater and/or component part to the manufacturer. WHAT IS THE PERIOD OF COVERAGE? This limited warranty runs from date of installation (or without proof of installation, from three (3) months after the date of manufacture) for the period specified on the following chart. To determine length of coverage, check model number listed on the rating plate of appliance against this chart. WHAT IS THE DURATION OF THE IMPLIED WARRANTY? ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY IMPOSED ON THE SALE OF THE WATER HEATER UNDER THE LAWS OF THE STATE OF SALE ARE LIMITED IN DURATION TO ONE YEAR FROM DATE OF ORIGINAL INSTALLATION. HOW DOES STATE LAW RELATE TO THE WARRANTY? Some states do not allow: 1. Limitations on how long an implied warranty lasts. 2. Limitations on incidental or consequential damages. So the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. LIMITED COMMERCIAL WATER HEATER WARRANTY MODEL NUMBER PREFIX LIMITED TANK** WARRANTY LIMITED PARTS** WARRANTY D, H, V, LD, DB, PDV, F-I, L-I-6, M,M-I, M-II, EF, LH-I, LV-I, TW, DH, SW, CDW, PDX, P, E, U, (U)LG, LE, LC, CEHD 1, 3, 5 or 6 YRS 1 YEAR M3ST, BST, NH, NV 5 YRS 1 YEAR No Letter Prefix 1,3 or 5 YRS 1 YEAR NOTE: The duration of the tank warranty will be found in the model number. i.e.; D80T1991N has a 1 Year tank warranty D80T1993N has a 3 Year tank warranty LG250H3N has a 3 Year tank warranty LG250H5N has a 5 Year tank warranty **All replacement water heaters and parts carry the balance of the original warranty, i.e. if an original three (3) year tank warranted water heater develops a leak due to defects in materials/workmanship after only two (2) years, the replacement unit is warranted for only the balance remaining from the original three (3) year warranty, or one (1) year in this example. Restrictions are not applicable to implied warranties in California. See “Special State Provisions” on reverse side. P/N 238-36612-00X (07/16) WHAT WILL WE DO TO CORRECT PROBLEMS? If a defect occurs within the warranty period, we will: 1. Provide a replacement water heater of our manufacture, (or at our option) repair any unit which develops a leak in the steel tank within the tank warranty period. To obtain a replacement, you must forward the rating plate from the defective unit to us. If government regulations require the replacement water heater to have features not found in the defective water heater, you will be required to pay the difference in price represented by those government required features. 2. Provide a replacement part (or at our option repair) any part which fails to function within the parts warranty period. To obtain a replacement, you must forward the defective part to us. If government regulations require the replacement part to have features not found in the defective part, you will be required to pay the difference in price represented by those government required features. We do reserve the right to verify any claims of defect by inspection. WHAT WILL WE NOT DO? We will not: 1. Repair or replace any water heater, or part, subject to conditions outlined in “What Does This Limited Warranty Not Cover?” 2. Reimburse any costs associated with repair and/or replacement. 3. Replace and/or repair any water heater without complete model/serial number. 4. Replace any water heater without prior receipt of actual rating plate from appliance. HOW DO YOU GET WARRANTY ASSISTANCE? Upon discovering a defect or problem, you should: 1. Contact either the installer or dealer, or 2. Contact us-- BRADFORD WHITE CORPORATION WARRANTY SUPPORT GROUP 200 LAFAYETTE STREET MIDDLEVILLE, MI 49333 (800) 531-2111 WHAT SHOULD YOU DO TO KEEP THE WARRANTY IN EFFECT? To facilitate warranty assistance, you should: 1. Follow all instructions enclosed with the product. 2. Retain all bills of sale or receipts for proof of installation, etc. 3. Contact your installer, dealer or our Warranty Department as soon as any problem or defect is noticed. 4. When necessary, allow us, or our chosen representative, to inspect the unit. 5. For your reference, fill in the Model and Serial Number found on the units Rating Plate: Model Number _____________________________ Serial Number ______________________________ Date of Installation __________________________ LIMITED COMMERCIAL WATER HEATER WARRANTY (CONTINUED) SPECIAL STATE PROVISIONS For water heaters installed in California or Oregon, Paragraphs 2(c) (i) (iv) of the paragraph “WHAT DOES THIS WARRANTY NOT COVER?” does not apply. All other terms and conditions of this warranty apply as stated. PLEASE RETAIN THIS WARRANTY IN A SAFE LOCATION FOR FUTURE REFERENCE.