HomeMy WebLinkAbout22 1319 Sanitary Waste Piping Specialties Revised REVIEWED AND APPROVEDSubmittal Transmittal SUBMITTAL TRANSMITTAL Project Name: Ithaca Arthaus Project Number : 18260 A Transmittal (from SUBCONTRACTOR) To:Vecino Construction, LLC Date Submitted Attn:Corey Olmstead Submittal No. (per Procore) corey@vecinogroup.com x Submitted for Review & Approval REV (0) Phone: (315) 854-0979 ReSubmitted for Review & Approval REV (1) From:Woodcock & Armani mike.meyer@comfortsystemsusa.com This is a FULL SUBMITTAL 315-701-2042 This is a PARTIAL Submittal Item No. Dwg. And/or Specification Section SpecParagraph / No.Title / Description Manufacturer Submittal Type Lead Time 1 22 1319 2.2 Cleanouts Zurn 2 22 1319 2.3 Floor Drains Zurn 3 22 1319 2.2C Wall Clean Outs Zurn 4 22 1319 2.4 Trap Seal SureSeal 5 6 7 8 9 10 11 Comments:Vecino Construction Stamp BW A&E Stamp Signature/Stamp of Transmitter Date 22 1319 2.2 Cleanouts 1 & 2 Zurn 22 1319 2.2 Cleanouts (Supplemental Info)Zurn Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice SPECIFICATION SHEET TAG _______ * Regularly furnished unless otherwise specified. Zurn Industries, LLC | Specification Drainage Operation 1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Z1400-HD "LEVEL-TROL" ADJUSTABLE FLOOR CLEANOUT W/ EXTRA HEAVY-DUTY TOP PIPE SIZE (Specify size/type) OUTLET 'E' BODY HT. DIM. 2,3,4,6 [51,76,102,152]_____ IC Inside Caulk See Chart 2,3,4,6,8 [51,76,102,152,203]_____ NH No-Hub See Chart 2,3,4,6,8 [51,76,102,152,203]_____ NL Neo-Loc See Chart ENGINEERING SPECIFICATION: ZURN ZN1400-HD "Level-Trol" Adjustable floor cleanout, Dura-Coated cast iron body, with gas and watertight ABS tapered thread plug, and round extra heavy-duty top adjustable to finished floor. OPTIONS (Check/specify appropriate options) PREFIXES ____ ZB D.C.C.I. with Polished Bronze Top ____ ZN D.C.C.I. with Polished Nickel Bronze Top* SUFFIXES ____ -AR Acid Resisting Epoxy Coated Finish ____ -BP Bronze Plug ____ -DC Duresist Cover ____ -G Galvanized Cast Iron ____ -K Anchor Flange ____ -KC Anchor Flange with Clamp Collar ____ -SG Solid Gasketed Cover ____ -SM Special Marking Stamped on Top ____ -T Square Top ____ -TC Neo-Loc Test Cap Gasket (2,3,4 [51,76,102] NL Bottom Outlet Only) ____ -VP Vandal-Proof Screws Rev. C Date:10/19/2017 C.N. No.138978 Prod. | Dwg. No. Z1400-HD Dimensions In Inches [mm] A-Pipe Size C E Approx. Wt. Lbs. [kg] Inside Caulk No-Hub Neo-Loc 2 [51]6-1/8 [156] 6-7/8 [175]16.1 [7] 3 [76]6-1/8 [156] 6-7/8 [175]15.8 [7] 4 [102] 7-1/4 [184] 6-7/8 [175]21.3 [10] 6 [152] 9-1/4 [235] 6-7/8 [175]33.7 [15] 2 [51]4-1/8 [105]4-5/8 [117]8.2 [4] 3 [76]4-1/8 [105] 4-3/4 [121]9.3 [4] 4 [102] 5-1/8 [130] 4-3/4 [121]12.9 [6] 6 [152] 8-1/4 [210] 4-3/4 [121]26.6 [12] 8 [203] 9-1/4 [235] 7-1/2 [191]36.1 [16] 2 [51]4-1/8 [105] 4-3/4 [121]9.5 [4] 3 [76]5-1/8 [130] 4-3/4 [121]13.2 [6] 4 [102] 5-1/8 [130] 4-3/4 [121]14.1 [6] 6 [152] 8-1/4 [210] 5-7/8 [149] 24 [11] 8 [203] 9-1/4 [235] 6-1/2 [165] 32 [15] Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice SPECIFICATION SHEET TAG _______ * Regularly furnished unless otherwise specified. Zurn Industries, LLC | Specification Drainage Operation 1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. G Date:09/28/2017 C.N. No.138032 Prod. | Dwg. No.Z1474 ENGINEERING SPECIFICATION: ZURN Z1474 Heavy Duty Cleanout Housing. Dura-Coated cast iron body with integral anchor flange, secured scoriated cover with lifting device. The cleanout housing has an approximate weight of 38 lbs. [17 kg]. OPTIONS (Check/specify appropriate options) PREFIXES ____ Z Dura-Coated Cast Iron* ____ ZN D.C.C.I. with Polished Nickel Bronze Top (Add 3/16 [5] to 11 [280] Dim. & 3/4 [19] to 9 [229] Dim.) SUFFIXES ____ -DC Duresist Cover ____ -G Galvanized Cast Iron ____ -N With Internal Cleanout (See Z1440) (4, 6 [102, 152] Outlets Only) ____ -SG Solid Gasketed Cover ____ -VP Vandal-Proof Screw Z1474 HEAVY DUTY CLEANOUT HOUSING Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice SPECIFICATION SHEET TAG _______ * Regularly furnished unless otherwise specified. Zurn Industries, LLC | Specification Drainage Operation 1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. T Date:09/26/2017 C.N. No.137871 Prod. | Dwg. No. Z415S ENGINEERING SPECIFICATION: ZURN ZN415S Floor and shower drain, Dura-Coated cast iron body with bottom outlet, combination invertible membrane clamp and adjustable collar with seepage slots and "TYPE S" polished nickel bronze, square heel-proof, light-duty strainer. OPTIONS (Check/specify appropriate options) PIPE SIZE (Specify size/type) OUTLET 'E' BODY HT. DIM. 2, 3, 4 [51, 76, 102] _____ IC Inside Caulk 4-3/16 [106] 2, 3, 4 [51, 76, 102] _____ IG Inside Gasket 4-3/16 [106] 2 [51] _____ IP Threaded 2-7/16 [62] 3 [76] _____ IP Threaded 2-3/4 [70] 4 [102] _____ IP Threaded 2-13/16 [71] 6 [152] _____ IP Threaded 2-7/8 [73] 2, 3, 4 [51, 76, 102] _____ NH No-Hub 3-13/16 [97] 2, 3, 4 [51, 76, 102] _____ NL Neo-Loc 3-7/8 [98] PREFIXES _____ZB D.C.C.I. Body Assembly w/ Polished Bronze Top _____ZN D.C.C.I. Body Assembly w/ Polished Nickel Bronze Top* SUFFIXES _____-AR Acid Resisting Epoxy Coated Cast Iron _____-CP Chrome-Plated Top _____-G Galvanized Cast Iron _____-HD Heavy-Duty Grate (ZN 6 x 6 [152 x 152] Only) _____-OF Oval Funnel (See Z329-7) (6,7,8,10 [152,178,203,254]) Strainers only) _____-P Trap Primer Connection (Specify 1/2 [13] or 3/4 [19]) _____-PC Protective Cover _____-SA Stabilizer Assembly (See Z1035) _____-SQ Stabilizer Q-Deck (See Z1035-Q) Z415S BODY ASSEMBLY W/ "TYPE S" STRAINER _____-TC Neo-Loc Test Cap Gasket (2,3,4 [51,76,102] NL Outlet Only) _____-U 1-3 [25-76] High Extension Adapter _____-V Backwater Valve _____-VP Vandal-Proof Secured Top _____-Y Sediment Bucket _____-4 4 [102] Diameter Funnel (Z328) _____-90 90° Threaded Side Outlet Body Assembly (2,3 [51,76] Only) 2, 3, [51, 76] 5 x 5 [127 x 127] 1 [25] 1-19/32 [40] 1-1/4 [32] 2-3/8 [60] 12 [5] 9 [58] 2, 3, 4 [51, 76, 102] 6 x 6 [152 x 152] 1 [25] 1-27/32 [47] 1-13/32 [36] 2-19/32 [66] 13 [6] 13 [84] 2, 3, 4 [51, 76, 102] 7 x 7 [178 x 178] 1 [25] 1-7/8 [48] 1-3/8 [35] 2-5/8 [67] 14 [6] 21 [135] 3, 4 [76, 102] 8 x 8 [203 x 203] 1-3/32 [28] 1-7/8 [48] 1-3/4 [44] 2-5/8 [67] 15 [7] 28 [181] 6 [152] 10 x 10 [254 x 254] 1-3/32 [28] 1-7/8 [48] 1-3/4 [44] 2-5/8 [67] 21 [10] 28 [181] Dimensions In Inches [mm] A Pipe Size B x B' Strainer Top Size Approx. Wt. Lbs. [kg] StrainerOpen AreaSq. In.[cm2] KK' Min.Max.Min.Max. Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice SPECIFICATION SHEET TAG _______ * Regularly furnished unless otherwise specified. Zurn Industries, LLC | Specification Drainage Operation 1801 Pittsburgh Avenue, Erie, PA 16502, Ph. 855-663-9876, Fax 814-454-7929 In Canada | Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 877-892-5216 www.zurn.com Rev.H Date:10/16/2019 C.N. No.141246 Prod. | Dwg. No.Z508 Z508 9 [229] DIAMETER TOP EXTRA-HEAVY-DUTY DRAIN WITH SEDIMENT BUCKET ENGINEERING SPECIFICATION: ZURN Z508 9" [229mm] Diameter top drain, Dura-Coated cast iron body with bottom outlet, seepage pan and combination membrane flashing clamp and frame with integrated trap primer and plug for extra-heavy-duty cast iron deep flange slotted duresist grate with sediment bucket. OPTIONS (Check/specify appropriate options) PIPE SIZE (Specify size/type) OUTLET 'E' BODY HT. DIM. 4 [102]____IC Inside Caulk 3-3/4 [95] 4 [102]____IG Inside Gasket 3-3/4 [95] 4 [102]____IP Threaded 2-3/4 [70] 2, 3, 4 [51, 76, 102]____NH No-Hub 4-3/4 [121] 6 [152]____NH No-Hub 5-1/4 [133] 2, 3, 4 [51, 76, 102]____NL Neo-Loc 3-9/16 [90] PREFIXES ____Z D.C.C.I. Body and Top* ____ZB D.C.C.I. Body with Polished Bronze Top (Add 3/16 [5] to 2 [51] Dim. and 3/4 [20] to 9 [229] Dim.) ____ZN D.C.C.I. Body with Polished Nickel Bronze Top (Add 3/16 [5] to 2 [51] Dim. and 3/4 [20] to 9 [229] Dim.) SUFFIXES ____-AR Acid Resisting Epoxy Coated Cast Iron ____-G Galvanized Cast Iron ____-HP Heel-Proof Grate ____-S Secondary Strainer ____-SC Solid Cover with Lift Handle ____-SG Solid Gasketed Cover with Lift Handle ____-TC Neo-Loc Test Cap Gasket (2, 3, 4 [51, 76, 102] NL Bottom Outlet Only) ____-TS Top Secured with Slotted Screws ____-VP Vandal-Proof Secured Top ____-90 90º Threaded Side Outlet Body (4 [102] Size Only) 2 [51] Ø12 [305] Ø9 [229] E A 1 2 [13] TRAP PRIMER CONNECTION 2, 3, 4 [51, 76, 102]22 [10] 6 [152]26 [12] A Pipe Size In.[mm] Approx. Wt. Lbs. [kg] Grate Open Area Sq. In. [cm2] 18 [116] Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice SPECIFICATION SHEET TAG _______ * Regularly furnished unless otherwise specified. Zurn Industries, LLC | Specification Drainage Operation 1801 Pittsburgh Avenue, Erie, PA 16502, Ph. 855-663-9876, Fax 814-454-7929 In Canada | Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 877-892-5216 www.zurn.com Rev.H Date:10/16/2019 C.N. No.141246 Prod. | Dwg. No.Z508 Z508 9 [229] DIAMETER TOP EXTRA-HEAVY-DUTY DRAIN WITH SEDIMENT BUCKET ENGINEERING SPECIFICATION: ZURN Z508 9" [229mm] Diameter top drain, Dura-Coated cast iron body with bottom outlet, seepage pan and combination membrane flashing clamp and frame with integrated trap primer and plug for extra-heavy-duty cast iron deep flange slotted duresist grate with sediment bucket. OPTIONS (Check/specify appropriate options) PIPE SIZE (Specify size/type) OUTLET 'E' BODY HT. DIM. 4 [102]____IC Inside Caulk 3-3/4 [95] 4 [102]____IG Inside Gasket 3-3/4 [95] 4 [102]____IP Threaded 2-3/4 [70] 2, 3, 4 [51, 76, 102]____NH No-Hub 4-3/4 [121] 6 [152]____NH No-Hub 5-1/4 [133] 2, 3, 4 [51, 76, 102]____NL Neo-Loc 3-9/16 [90] PREFIXES ____Z D.C.C.I. Body and Top* ____ZB D.C.C.I. Body with Polished Bronze Top (Add 3/16 [5] to 2 [51] Dim. and 3/4 [20] to 9 [229] Dim.) ____ZN D.C.C.I. Body with Polished Nickel Bronze Top (Add 3/16 [5] to 2 [51] Dim. and 3/4 [20] to 9 [229] Dim.) SUFFIXES ____-AR Acid Resisting Epoxy Coated Cast Iron ____-G Galvanized Cast Iron ____-HP Heel-Proof Grate ____-S Secondary Strainer ____-SC Solid Cover with Lift Handle ____-SG Solid Gasketed Cover with Lift Handle ____-TC Neo-Loc Test Cap Gasket (2, 3, 4 [51, 76, 102] NL Bottom Outlet Only) ____-TS Top Secured with Slotted Screws ____-VP Vandal-Proof Secured Top ____-90 90º Threaded Side Outlet Body (4 [102] Size Only) 2 [51] Ø12 [305] Ø9 [229] E A 1 2 [13] TRAP PRIMER CONNECTION 2, 3, 4 [51, 76, 102]22 [10] 6 [152]26 [12] A Pipe Size In.[mm] Approx. Wt. Lbs. [kg] Grate Open Area Sq. In. [cm2] 18 [116] Contact: RectorSeal® 2601 Spenwick Drive, Houston, TX 77055 713-263-8001 800-231-3345 713-263-7577 800-441-0051 rectorseal.comP F W A CSW Industrials Company P-J-15 Specification: SureSeal model SS2009V Waterless Inline 2" Drain Trap Seal. HDPE (High Density Poly Ethylene) housing with heavy duty proprietary silicone diaphragm and soft EPDM rubber sealing gasket. Floor rating ASSE 1072 AF GW. Function: Installs into the outlet of drain bodies, or drain hubs to protect the trap seal from evaporation. Creates a physical barrier that blocks sewer gases and their odors from escaping. Provides waterless trap seal protection equivalent to water based trap primers. · New Construction: Used as a trap primer replacement or in conjunction with a trap primer to provide protection against escaping sewer gases. Eliminates the need to repair/replace trap primers when they fail. · Retrofit: Used in situations where trap primers have failed or where trap primers were never installed. Benefits: Simple to install, eliminates the need for complex, time consuming, and expensive repairs. ECO friendly providing 100% water savings efficiency over traditional methods. ICC-ES Listed: PMG-1070 IAPMO Listed: C-4165 U.S. Patent 9,010363 Other Patent Pending 2.0050.80 2.2055.88 2.3559.69 .5914.90 AA PART MARKINGS ARE PERMANENTLYAFFIXED TO THE PART IN THE MOLDING PROCESS 5REF 1REF6REF 2.1053.34 1.7644.83 1.8145.91 1.3033.05 SECTION A-A 21 3 6 4 5 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 10/16/2013 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 12-400-004 2IN SHIELD 1 22-400-001 2 IN HOUSING 1 32-400-005 2IN FLAPPER 1 42-400-002 2 INCH RETAINER CLIP 1 52-400-015 2IN MEMBRANE 1 62-400-006 2IN UNIVERSAL GASKET 1 D C B AA B C D 12345678 87654 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHES TOLERANCES: PER RMA "A3" COMMERCIAL UNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 2IN VENTED ASSY 2-400-100 N/A N/A SureSeal Manufacturing 1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 22 - JUL - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 22 - JUL - 2013 Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer FloorBEFOREAFTERRectorSeal · 2601 Spenwick Drive · Houston, TX 77055 RectorSeal.com Toll Free: (800) 231-3345 · (713) 263-8001 · Fax: (713) 263-7577 2" SureSeal®MODEL #SS2009V INLINE FLOOR DRAIN TRAP SEALER The Green Solution 2.0050.80 2.2055.88 2.3559.69 .5914.90 AA PART MARKINGS ARE PERMANENTLYAFFIXED TO THE PART IN THE MOLDING PROCESS 5REF 1REF 6 REF 2.1053.34 1.7644.83 1.8145.91 1.3033.05 SECTION A-A 21 3 6 4 5 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 10/16/2013 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 1 2-400-004 2IN SHIELD 1 2 2-400-001 2 IN HOUSING 1 3 2-400-005 2IN FLAPPER 1 4 2-400-002 2 INCH RETAINER CLIP 1 5 2-400-015 2IN MEMBRANE 1 6 2-400-006 2IN UNIVERSAL GASKET 1 D C B AA B C D 12345678 87 6 5 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHESTOLERANCES:PER RMA "A3" COMMERCIALUNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 2IN VENTED ASSY 2-400-100 N/A N/A SureSeal Manufacturing1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 22 - JUL - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 22 - JUL - 2013 HOUSING (NO GASKET) 2.0050.80 2.2055.88 2.3559.69 .5914.90 AA PART MARKINGS ARE PERMANENTLYAFFIXED TO THE PART IN THE MOLDING PROCESS 2.1053.34 1.7644.83 1.8145.91 1.3033.05 SECTION A-A 2.0050.80 2.2055.88 2.3559.69 .5914.90 AA PART MARKINGS ARE PERMANENTLYAFFIXED TO THE PART IN THE MOLDING PROCESS 2.1053.34 1.7644.83 1.8145.91 1.3033.05 SECTION A-A 2.0050.80 2.2055.88 2.3559.69 .5914.90 AA PART MARKINGS ARE PERMANENTLYAFFIXED TO THE PART IN THE MOLDING PROCESS 5 REF 1 REF 6 REF 2.1053.34 1.7644.83 1.8145.91 1.3033.05 SECTION A-A 21 3 6 4 5 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 10/16/2013 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 1 2-400-004 2IN SHIELD 1 2 2-400-001 2 IN HOUSING 1 3 2-400-005 2IN FLAPPER 1 4 2-400-002 2 INCH RETAINER CLIP 1 5 2-400-015 2IN MEMBRANE 1 6 2-400-006 2IN UNIVERSAL GASKET 1 D C B AA B C D 12345678 8 7 6 5 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHESTOLERANCES:PER RMA "A3" COMMERCIALUNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 2IN VENTED ASSY 2-400-100 N/A N/A SureSeal Manufacturing1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 22 - JUL - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 22 - JUL - 2013 HOUSING (NO GASKET)& GASKET Contact: RectorSeal® 2601 Spenwick Drive, Houston, TX 77055 713-263-8001 800-231-3345 713-263-7577 800-441-0051 rectorseal.comP F W A CSW Industrials Company P-J-15 Specification: SureSeal model SS3009V Waterless Inline 3" Drain Trap Seal. HDPE (High Density Poly Ethylene) housing with proprietary heavy duty silicone diaphragm and soft EPDM rubber sealing gasket. Floor rating ASSE 1072 AF GW. Function: Installs into the outlet of drain bodies, or drain hubs to protect the trap seal from evaporation. Creates a physical barrier that blocks sewer gases and their odors from escaping. Provides waterless trap seal protection equivalent to water based trap primers. · New Construction: Used as a trap primer replacement or in conjunction with a trap primer to provide protection against escaping sewer gases. Eliminates the need to repair/replace trap primers when they fail. · Retrofit: Used in situations where trap primers have failed or where trap primers were never installed. Benefits: Simple to install, eliminates the need for complex, time consuming, and expensive repairs. ECO friendly providing 100% water savings efficiency over traditional methods. 3.2382 2.7670 2.9073.75 .7519.05 AA 2.9274.12 1.5238.64 2.6968.43 2.7569.85 SECTION A-A 1 5 46 3 2 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 12/15/2012 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 1 3-400-001 3 INCH BODY 1 2 3-400-004 3IN SHIELD 1 3 3-400-005 3IN FLAPPER 1 4 3-400-015 3IN MEMBRANE 1 5 3-400-006 3IN UNIVERSAL GASKET 1 6 3-400-002 3 INCH RETAINER CLIP 1 D C B AA B C D 12345678 8765 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHESTOLERANCES: PER RMA "A3" COMMERCIAL UNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 3IN ASSY 3-400-100 N/A N/A SureSeal Manufacturing 1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 22 - JUL - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 22 - JUL - 2013 Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer FloorBEFOREAFTERRectorSeal · 2601 Spenwick Drive · Houston, TX 77055 RectorSeal.com Toll Free: (800) 231-3345 · (713) 263-8001 · Fax: (713) 263-7577 ICC-ES Listed: PMG-1070 IAPMO Listed: C-4165 U.S. Patent 9,010363 Other Patent Pending 3" SureSeal® MODEL #SS3009V INLINE FLOOR DRAIN TRAP SEALER The Green Solution 3.2382 2.7670 2.9073.75 .7519.05 AA 2.9274.12 1.5238.64 2.6968.43 2.7569.85 SECTION A-A 1 5 46 3 2 REVISIONSZONEREV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 12/15/2012 DFC ITEM NO.PART NUMBER DESCRIPTION QTY.1 3-400-001 3 INCH BODY 1 2 3-400-004 3IN SHIELD 1 3 3-400-005 3IN FLAPPER 1 4 3-400-015 3IN MEMBRANE 1 5 3-400-006 3IN UNIVERSAL GASKET 1 6 3-400-002 3 INCH RETAINER CLIP 1 D C B AA B C D 12345678 87 6 5 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHESTOLERANCES:PER RMA "A3" COMMERCIALUNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 3IN ASSY 3-400-100 N/A N/A SureSeal Manufacturing1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 22 - JUL - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 22 - JUL - 2013 HOUSING (NO GASKET)HOUSING & GASKET 3.2382 2.7670 2.9073.75 .7519.05 AA 2.9274.12 1.5238.64 2.6968.43 2.7569.85 SECTION A-A 1 5 46 3 2 REVISIONSZONEREV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 12/15/2012 DFC ITEM NO.PART NUMBER DESCRIPTION QTY.1 3-400-001 3 INCH BODY 1 2 3-400-004 3IN SHIELD 1 3 3-400-005 3IN FLAPPER 1 4 3-400-015 3IN MEMBRANE 1 5 3-400-006 3IN UNIVERSAL GASKET 1 6 3-400-002 3 INCH RETAINER CLIP 1 D C B AA B C D 12345678 8 7 6 5 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHESTOLERANCES:PER RMA "A3" COMMERCIALUNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 3IN ASSY 3-400-100 N/A N/A SureSeal Manufacturing1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 22 - JUL - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 22 - JUL - 2013 3.2382 2.7670 2.9073.75 .7519.05 AA 2.9274.12 1.5238.64 2.6968.43 2.7569.85 SECTION A-A 3.2382 2.7670 2.9073.75 .7519.05 AA 2.9274.12 1.5238.64 2.6968.43 2.7569.85 SECTION A-A Contact: RectorSeal® 2601 Spenwick Drive, Houston, TX 77055 713-263-8001 800-231-3345 713-263-7577 800-441-0051 rectorseal.comP F W A CSW Industrials Company P-J-15 Specification: SureSeal model SS3509V Waterless In-line 3.5" Drain Trap Seal. HDPE (High Density Poly Ethylene) housing with proprietary EPDM rubber diaphragm and soft rubber sealing gasket. Floor rating ASSE 1072 AF GW. Function: Installed into drain strainers or drain hubs to protect the trap seal from evaporation. Creates a physical barrier that blocks sewer gases and their odors from escaping. Provides waterless trap seal protection equivalent to water based trap primers. · New Construction: Used as a trap primer replacement or in conjunction with a trap primer to provide protection against escaping sewer gases. Eliminates the need to repair/replace trap primers when they fail. · Retrofit: Used in situations where trap primers have failed or where trap primers were never installed. Benefits: Simple to install, eliminates the need for complex, time consuming, and expensive repairs. ECO friendly providing 100% water savings efficiency over traditional methods. AA SECTION A-A 1 2 36 5 4 3.75 95.25 3.55 90.17 .8521.50 2.7569.81 2.69 68.43 .73 18.50 3.14 79.74 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 12/15/2012 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 1 SSM5-105 3.5 INCH GASKET 1 2 35-400-001 3.5IN HOUSING 1 3 3-400-015 3IN MEMBRANE 1 4 3-400-004 3IN SHIELD 1 5 3-400-005 3IN FLAPER 1 6 3-400-002 3 INCH RETAINER CLIP 1 D C B AA B C D 12345678 876 5 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV. B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHES TOLERANCES: PER RMA "A3" COMMERCIAL UNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 3.5IN VENTED ASSY 35-400-100 N/A N/A SureSeal Manufacturing 1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 22 - JUL - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 22 - JUL - 2013BEFOREAFTERDrain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer FloorDrain Outlet SureSeal Strainer Floor A B ICC-ES Listed: PMG-1070 IAPMO Listed: C-4165 U.S. Patent 9,010363 Other Patent Pending 3.5" SureSeal®MODEL #SS3509V INLINE FLOOR DRAIN TRAP SEALER The Green Solution AA SECTION A-A 1 2 36 5 4 3.7595.25 3.5590.17 .8521.50 2.7569.81 2.6968.43 .7318.50 3.1479.74 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 12/15/2012 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 1 SSM5-105 3.5 INCH GASKET 1 2 35-400-001 3.5IN HOUSING 1 3 3-400-015 3IN MEMBRANE 1 4 3-400-004 3IN SHIELD 1 5 3-400-005 3IN FLAPER 1 6 3-400-002 3 INCH RETAINER CLIP 1 D C B AA B C D 12345678 8 7 6 5 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHESTOLERANCES:PER RMA "A3" COMMERCIALUNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 3.5IN VENTED ASSY 35-400-100 N/A N/A SureSeal Manufacturing1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 22 - JUL - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 22 - JUL - 2013 HOUSING & GASKETHOUSING (NO GASKET) AA SECTION A-A 1 2 36 5 4 3.7595.25 3.5590.17 .8521.50 2.7569.81 2.6968.43 .7318.50 3.1479.74 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 12/15/2012 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 1 SSM5-105 3.5 INCH GASKET 1 2 35-400-001 3.5IN HOUSING 1 3 3-400-015 3IN MEMBRANE 1 4 3-400-004 3IN SHIELD 1 5 3-400-005 3IN FLAPER 1 6 3-400-002 3 INCH RETAINER CLIP 1 D C B AA B C D 12345678 87 6 5 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALSDATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHESTOLERANCES:PER RMA "A3" COMMERCIALUNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 3.5IN VENTED ASSY 35-400-100 N/A N/A SureSeal Manufacturing1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 22 - JUL - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 22 - JUL - 2013 AA SECTION A-A Contact: RectorSeal® 2601 Spenwick Drive, Houston, TX 77055 713-263-8001 800-231-3345 713-263-7577 800-441-0051 rectorseal.comP F W A CSW Industrials Company P-J-15 Specification: SureSeal model SS4009V Waterless Inline 4" Drain Trap Seal. HDPE (High Density Poly Ethylene) housing with heavy duty silicone proprietary diaphragm and soft EPDM sealing gasket. Floor rating ASSE 1072 AF GW. Function: Installs into the outlet of drain bodies, drain strainers, or drain hubs to protect the trap seal from evaporation. Creates a physical barrier that blocks sewer gases and their odors from escaping. Provides waterless trap seal protection equivalent to water based trap primers. · New Construction: Used as a trap primer replacement or in conjunction with a trap primer to provide protection against escaping sewer gases. Eliminates the need to repair/replace trap primers when they fail. · Retrofit: Used in situations where trap primers have failed or where trap primers were never installed. Benefits: Simple to install, eliminates the need for complex, time consuming, and expensive repairs. ECO friendly providing 100% water savings efficiency over traditional methods. AA PART MARKINGS ARE PERMANENTLYAFFIXED TO THE PART IN THE MOLDING PROCESS 6 5 2REF REF REF SECTION A-A 1 6 5 3 2 4 110.134.34 104.924.13 103.714.08 82.483.25 30.471.20 28.951.14 81.543.21 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 10/03/2013 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 1 4-400-001 4 INCH HOUSING 1 2 4-400-004 4IN SHIELD 1 3 3-400-005 3IN FLAPPER 1 4 4-400-002 4 INCH RETAINER CLIP 1 5 4-400-015 4IN MEMBRANE 1 6 4-400-006 4 INCH GASKET 1 D C B AA B C D 12345678 876 5 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHESTOLERANCES:PER RMA "A3" COMMERCIALUNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 4IN VENTED ASSY 4-400-100 N/A N/A SureSeal Manufacturing1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 03 - OCT - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 03 - OCT - 2013 HOUSING (NO GASKET) AA PART MARKINGS ARE PERMANENTLYAFFIXED TO THE PART IN THE MOLDING PROCESS 6 5 2 REF REF REF SECTION A-A 1 6 5 3 2 4 110.134.34 104.924.13 103.714.08 82.483.25 30.471.20 28.951.14 81.543.21 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 10/03/2013 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 1 4-400-001 4 INCH HOUSING 1 2 4-400-004 4IN SHIELD 1 3 3-400-005 3IN FLAPPER 1 4 4-400-002 4 INCH RETAINER CLIP 1 5 4-400-015 4IN MEMBRANE 1 6 4-400-006 4 INCH GASKET 1 D C B AA B C D 12345678 8 7 6 5 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHESTOLERANCES:PER RMA "A3" COMMERCIALUNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 4IN VENTED ASSY 4-400-100 N/A N/A SureSeal Manufacturing1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 03 - OCT - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 03 - OCT - 2013 HOUSING & GASKET AA PART MARKINGS ARE PERMANENTLYAFFIXED TO THE PART IN THE MOLDING PROCESS 6 5 2REF REF REF SECTION A-A 1 6 5 32 4 110.134.34 104.924.13 103.714.08 82.483.25 30.471.20 28.951.14 81.543.21 REVISIONS ZONE REV.DESCRIPTION DATE APPROVED N/A A00 RELEASED FOR PRODUCTION 10/03/2013 DFC ITEM NO.PART NUMBER DESCRIPTION QTY. 1 4-400-001 4 INCH HOUSING 1 2 4-400-004 4IN SHIELD 1 3 3-400-005 3IN FLAPPER 1 4 4-400-002 4 INCH RETAINER CLIP 1 5 4-400-015 4IN MEMBRANE 1 6 4-400-006 4 INCH GASKET 1 D C B AA B C D 12345678 8765 4 2 1 SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE SIZE REV.B A00 APPROVALS DATEDRAWN CHECKED MATERIAL FINISH 3 DIMENSIONS ARE IN INCHES TOLERANCES: PER RMA "A3" COMMERCIAL UNLESS OTHERWISE SPECIFIED UNLESS OTHERWISE SPECIFIED: 4IN VENTED ASSY 4-400-100 N/A N/A SureSeal Manufacturing 1614 South Mildred StreetSuite 12Tacoma, WA 98465 USA (877) 201-2663 Toll-Free PART NO DESCRIPTION DFC DH 03 - OCT - 2013DATE PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED. THIRD ANGLE PROJECTION 03 - OCT - 2013BEFOREAFTERDrain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet Strainer Floor Drain Outlet SureSeal Strainer Floor Drain Outlet SureSeal Strainer FloorDrain Outlet SureSeal Strainer Floor A B ICC-ES Listed: PMG-1070 IAPMO Listed: C-4165 U.S. Patent 9,010363 Other Patent Pending 4" SureSeal® MODEL #SS4009V INLINE FLOOR DRAIN TRAP SEALER The Green Solution SECTION A-A AA PART MARKINGS ARE PERMANENTLYAFFIXED TO THE PART IN THE MOLDING PROCESS *REGULARLY FURNISHED UNLESS OTHERWISE SPECIFIED Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice ZURN INDUSTRIES, LLC ♦♦♦♦♦ SPECIFICATION DRAINAGE OPERATION ♦♦♦♦♦ 1801 Pittsburgh Ave. ♦♦♦♦♦ Erie, PA 16514 Phone: 814/455-0921 ♦♦♦♦♦ Fax: 814/454-7929 ♦♦♦♦♦ World Wide Web: www.zurn.com In Canada: ZURN INDUSTRIES LIMITED ♦♦♦♦♦ 3544 Nashua Drive ♦♦♦♦♦ Mississauga, Ontario L4V1L2 ♦♦♦♦♦ Phone: 905/405-8272 Fax: 905/405-1292 SPECIFICATION SHEET TAG _______® Z1468 ACCESS COVER AND PLUG DWG. NO. 58781 REV. D PRODUCT NO. Z1468 DATE: 11/5/10 C.N. NO. 120267 ENGINEERING SPECIFICATION: ZURN ZS1468 Round stainless steel wall access cover complete with securing screw and bronze raised hex head plug. OPTIONS (Check/specify appropriate options) PREFIXES ____ ZAB Bronze Plug with Polished Bronze Cover ____ ZS Bronze Plug with Stainless Steel Cover* SUFFIXES ____ -SL Screw Longer Than 3 1/2 [89] ____ -VP Vandal-Proof Screw A-Pipe Size B Dimensions In Inches Approx. Wt. Lbs. [kg] 4 [2] 5 [2] 6 [3] 8 [4] 11 [5] 14 [6] 25 [11] 4 [102] 5 [127] 7 [178] 9 [229] 11 [279] Product Designation -1.25 1-1/4 [32] -1.5 1-1/2 [38] -2 2 [51] -2.5 2-1/2 [64] -3 3 [76] -3.5 3-1/2 [89] -4 4 [102] -5 5 [127] -6 6 [152] -8 8 [203] Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice SPECIFICATION SHEET TAG _______ * Regularly furnished unless otherwise specified. Zurn Industries, LLC | Specification Drainage Operation 1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Z1400-BZ "LEVEL-TROL" ADJUSTABLE LEVELING FLOOR CLEANOUT Rev. C Date:06/04/14 C.N. No.131072 Prod. | Dwg. No.Z1400-BZ PIPE SIZE (Specify size/type) OUTLET 'E' BODY HT. DIM. 4 [102]_____ NH No-Hub See Chart 3-4 [76-102]_____ NL Neo-Loc See Chart Neo-Loc No-Hub A-Pipe Size C E Approx. Wt. Lbs. [kg.] Dimension In Inches 4 [102] 3 [76] 4 [102] 10.6 [4.8] 11.9 [5.4] 4-3/4 [121] 4-3/4 [121] 4-3/4 [121] 5-1/32 [128] 5-1/32 [128] 5-1/32 [128] 10.3 [4.7] OPTIONS (Check/specify appropriate options) PREFIXES ____ ZB D.C.C.I. w/ Polished Bronze Top ____ ZN D.C.C.I. w/ Polished Nickel Bronze Top ____ ZS D.C.C.I. w/ Polished Type 304 (CF8) Stainless Steel Top SUFFIXES ____ -AR Acid Resisting Epoxy Coated Finish ____ -BP Bronze Plug ____ -CM Carpet Marker ____ -G Galvanized Cast Iron ____ -K Anchor Flange ____ -KC Anchor Flange w/ Clamping Collar ____ -PC Protective Cover ____ -SM Special Marking Stamped on Top ____ -TC Neo-Loc Test Cap Gasket (3-4 [76-102] NL Bottom Outlet Only) ____ -VP Vandal-Proof Screws ENGINEERING SPECIFICATION: ZURN Z1400-BZ "Level-Trol" Adjustable leveling floor cleanout, Dura-Coated cast iron body, with gas and watertight ABS tapered thread plug, and round scoriated secured light-duty top (Specify finish ZB, ZN, ZS) with additional leveling adjustment to finished floor. PATENT PENDING CLEANOUTS ZURN PLUMBING PRODUCTS GROUP SPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA 16502 PHONE 814/455-0921 FAX: 814/454-7929 WEBSITE: www.zurn.com Page 4 APPLICATION INDEX Product selection should be made with a specific application and the type of construction in mind.The varied types and sizes of Zurn cleanouts along with their options, offer a selection for all applications. APPLICATION TYPE RECOMMENDED CLEANOUT “Level-Trol”Adjustable ZN1400, ZN1454 Non-Adjustable ZN1402, ZN1455 Linoleum,Tile or Composition ZN1400-TX (Square), Finished Floor Areas Floors (Adjustable) ZN1400-X (Round) Linoleum,Tile or Composition ZN1402-TX (Square), Floors (Non-Adjustable) ZN1402-X (Round) Terrazzo Floors ZN1400-Z “Level-Trol”Adjustable Z1400-HD (Round or Square) Non-Adjustable Z1402-HD, Z1474 Medium Traffic Adjustable (Finished Area) Z1454, Z1404, and Areaways Non-Adjustable Z1455 Horizontal and Vertical Cleanouts Horizontal Cleanouts Z1441, Z1443, Z1444, Z1446 with Access Covers Z1447, Z1448 Round Access Cover ZN1441, ZN1444, ZN1446 Square Access Cover ZN1443, ZN1447, ZN1448 Deck Areas Z1456, Z1457, Z1463 Square Covers Z1460, Z1461, Z1462 Round Covers Z1463, Z1469, Z1475 Access Boxes Z1464, Z1467 Air Inlets Finished Areas Z1471, Z1472, Z1473 Cleanout Z1440, Z1445, Z1449 Cleanout Plug Z1470 Heavy Traffic and Industrial Areas Exposed Drainage Lines Z1440, Z1445 Concealed Drainage Lines Access Covers and Boxes General Purpose Finished Wall Areas