Loading...
HomeMy WebLinkAbout22 1116 Domestic Water Piping resubmittal REVIEWED AND APPROVEDSubmittal Transmittal SUBMITTAL TRANSMITTAL Project Name: Ithaca Arthaus Project Number : 18260 A Transmittal (from SUBCONTRACTOR) To:Vecino Construction, LLC Date Submitted Attn:Corey Olmstead Submittal No. (per Procore) corey@vecinogroup.com Submitted for Review & Approval REV (0) Phone: (315) 854-0979 x ReSubmitted for Review & Approval REV (1) From:Woodcock & Armani mike.meyer@comfortsystemsusa.com This is a FULL SUBMITTAL 315-701-2042 x This is a PARTIAL Submittal Item No. Dwg. And/or Specification Section SpecParagraph / No.Title / Description Manufacturer Submittal Type Lead Time 1 22 1116 2.2C Domestic water piping (piping within units)Uponor 2 3 4 5 6 7 8 9 10 11 Comments:Vecino Construction Stamp BW A&E Stamp The pex piping will be within the units, and be home runs from the manifold to each fixture The manifold will have a single valve on the inlet (not individual branch valves)as allowed by the 2018 NYS HCR Design Handbook(see attached) Signature/Stamp of Transmitter Date 1ProPEX® is a registered trademark of Uponor Inc. ProPEX™ is a trademark of Uponor Ltd.; 2Visit listing agency’s website for complete information. Uponor AquaPEX® red coils and straight lengths Submittal information Revision I: Nov. 7, 2018 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer’s representative: Approved by: Technical data Material: Crosslinked polyethylene PEX-a Engel method; PEX 5306 Standard grade Hydrostatic ratings (PPI): 200°F at 80 psi (93°C at 5.5 bar) 180°F at 100 psi (82°C at 6.9 bar) 73.4°F at 160 psi (23°C at 11 bar) Linear expansion rate: 1.10"/10°F/100' (27.94mm/5.56°C/30.48m) Product information and application use Uponor AquaPEX® red tubing is used primarily for hot potable-water distribution, but can also be used in radiant heating and cooling systems containing no ferrous corrodible components or where ferrous components are isolated from the tubing.  Description Part number I.D. O.D. Weight ½" Uponor AquaPEX Red, 100-ft. coil ½" Uponor AquaPEX Red, 300-ft. coil ½" Uponor AquaPEX Red, 1,000-ft. coil ¾" Uponor AquaPEX Red, 100-ft. coil ¾" Uponor AquaPEX Red, 300-ft. coil ¾" Uponor AquaPEX Red, 500-ft. coil 1" Uponor AquaPEX Red, 100-ft. coil 1" Uponor AquaPEX Red, 300-ft. coil 1" Uponor AquaPEX Red, 500-ft. coil ½" Uponor AquaPEX Red, 20-ft. straight length, 500 ft. ¾" Uponor AquaPEX Red, 20-ft. straight length, 300 ft. 1" Uponor AquaPEX Red, 20-ft. straight length, 200 ft. F2040500 F2060500 F2120500 F2040750 F2060750 F2100750 F2041000 F2061000 F2101000 F2930500 F2930750 F2921000 0.475" 0.475" 0.475" 0.671" 0.671" 0.671" 0.862" 0.862" 0.862" 0.475" 0.671" 0.862" 0.625" 0.625" 0.625" 0.875" 0.875" 0.875" 1.125" 1.125" 1.125" 0.625" 0.875" 1.125" 6 lbs. 18 lbs. 54 lbs. 10 lbs. 34 lbs. 54 lbs. 20 lbs. 56 lbs. 93 lbs. 28 lbs. 31 lbs. 35 lbs. Installation Approved fitting system is ProPEX®1. Refer to the Uponor ProPEX Connections Instructional Guide, the Uponor Professional Plumbing Installation Guide or the Uponor Piping Pocket Guide for more information. Listings2 cNSFus-pw; cQAIus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC Codes ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada Standards ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; AWWA C904; CSA B137.5; CSA B214 Related applications Contact information PEX-a plumbing systems Radiant heating and cooling systems Uponor Inc. 5925 148th Street West Apple Valley, MN 55124 USA T 800.321.4739 F 952.891.2008 uponorpro.com Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA T 888.994.7726 F 800.638.9517 uponorpro.com 1ProPEX® is a registered trademark of Uponor Inc. ProPEX™ is a trademark of Uponor Ltd.; 2Visit listing agency’s website for complete information. Uponor AquaPEX® blue coils and straight lengths Submittal information Revision I: Nov. 7, 2018 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer’s representative: Approved by: Technical data Material: Crosslinked polyethylene PEX-a Engel method; PEX 5306 Standard grade hydrostatic ratings (PPI): 200°F at 80 psi (93°C at 5.5 bar) 180°F at 100 psi (82°C at 6.9 bar) 73.4°F at 160 psi (23°C at 11 bar) Linear expansion rate: 1.10"/10°F/100' (27.94mm/5.56°C/30.48m) Product information and application use Uponor AquaPEX® blue tubing is used primarily in cold potable-water distribution systems, but can also be used in radiant heating and cooling systems containing no ferrous corrodible components or where ferrous components are isolated from the tubing.  Description Part number I.D. O.D. Weight ½" Uponor AquaPEX Blue, 100-ft. coil ½" Uponor AquaPEX Blue, 300-ft. coil ½" Uponor AquaPEX Blue, 1,000-ft. coil ¾" Uponor AquaPEX Blue, 100-ft. coil ¾" Uponor AquaPEX Blue, 300-ft. coil ¾" Uponor AquaPEX Blue, 500-ft. coil 1" Uponor AquaPEX Blue, 100-ft. coil 1" Uponor AquaPEX Blue, 300-ft. coil 1" Uponor AquaPEX Blue, 500-ft. coil ½" Uponor AquaPEX Blue, 20-ft. straight length, 500 ft. ¾" Uponor AquaPEX Blue, 20-ft. straight length, 300 ft. 1" Uponor AquaPEX Blue, 20-ft. straight length, 200 ft. F3040500 F3060500 F3120500 F3040750 F3060750 F3100750 F3041000 F3061000 F3101000 F3930500 F3930750 F3921000 0.475" 0.475" 0.475" 0.671" 0.671" 0.671" 0.862" 0.862" 0.862" 0.475" 0.671" 0.862" 0.625" 0.625" 0.625" 0.875" 0.875" 0.875" 1.125" 1.125" 1.125" 0.625" 0.875" 1.125" 6 lbs. 18 lbs. 54 lbs. 10 lbs. 34 lbs. 54 lbs. 20 lbs. 56 lbs. 93 lbs. 28 lbs. 31 lbs. 35 lbs. Installation Approved fitting system is ProPEX®1. Refer to the Uponor ProPEX Connections Instructional Guide, the Uponor Professional Plumbing Installation Guide or the Uponor Piping Pocket Guide for more information. Listings2 cNSFus-pw; cQAIus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC Codes ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada Standards ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; AWWA C904; CSA B137.5; CSA B214 Related applications Contact information PEX-a plumbing systems Radiant heating and cooling systems Uponor Inc. 5925 148th Street West Apple Valley, MN 55124 USA T 800.321.4739 F 952.891.2008 uponorpro.com Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA T 888.994.7726 F 800.638.9517 uponorpro.com 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. 1" Branch Manifold with ½" ProPEX® Lead-free (LF) Outlets Submittal information Revision B: Aug. 2, 2017 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer’s representative: Approved by: Technical data Material: Type L copper; C69300 brass Maximum temperature (no pressure): 320°F (160°C) Maximum working temperature/pressure: 210°F at 150 psi (99°C at 10 bar) Maximum flow rate at 5 fps: 12.8 gpm Maximum flow rate at 8 fps: 20.5 gpm Product information and application use The Uponor 1" Copper Branch Manifold with ½" ProPEX® Lead-free (LF) Outlets is used for hot and cold domestic potable-water distribution systems.1 The manifold has a 1" copper sweat fitting adapter supply connection. All outlets are configured with ½" ProPEX LF brass connections.  Description Part number A B C D Weight 1" Branch Manifold with ½" ProPEX LF outlets, 4 outlets LF2801050 8.95" 2.40" 1.50" ½" 0.80 lbs. 1" Branch Manifold with ½" ProPEX LF outlets, 6 outlets LF2811050 11.95" 2.40" 1.50" ½" 1.10 lbs. 1" Branch Manifold with ½" ProPEX LF outlets, 8 outlets LF2821050 14.95" 2.40" 1.50" ½" 1.40 lbs. 1" Branch Manifold with ½" ProPEX LF outlets, 10 outlets LF2831050 17.95" 2.40" 1.50" ½" 1.70 lbs. 1" Branch Manifold with ½" ProPEX LF outlets, 12 outlets LF2841050 20.95" 2.40" 1.50" ½" 1.90 lbs. Installation Use any product designed to mount 1" copper pipe as a mounting bracket. Any bend within 6 inches of the ProPEX connection to the manifold requires the use of a Tube Talon (F7050750) or Bend Support (A5110500 and A5150500). Refer to the Uponor Commercial Piping Pocket Guide, Uponor AquaSAFE™ Residential Fire Sprinkler Installation Guide or the Uponor Radiant Installation Handbook for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings ICC ESR 1099; ANSI/NSF 14- and 61-certified; IAPMO; U.P. Code, Annex G Related applications Contact information PEX-a plumbing systems Residential fire safety systems Radiant heating and cooling systems Uponor Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739 Fax: 952.891.2008 uponorpro.com Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA Phone: 888.994.7726 Fax: 800.638.9517 uponorpro.com ProPEX® Lead-free Copper Stub Ell, PEX LF Brass x Copper Submittal Information Revision A: Jan. 27, 2010 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer’s Representative: Approved By: Technical Data Material: C69300 Brass; Type L Copper Product Information and Application Use The Uponor ProPEX® Lead-free Copper Stub Ell provides a 90° transition from Uponor AquaPEX® tubing to copper.1 The copper stub ell is comprised of ½" copper pipe with an Uponor ProPEX Fitting on one end and the other end spun closed. 9 Description Part Number A B Weight ProPEX LF Copper Stub Ell, ½" PEX LF Brass x ½" Copper (3½" x 8") LF2865050 4.75" 8.30" 0.20 lbs. ProPEX LF Copper Stub Ell, ½" PEX LF Brass x ½" Copper (8" x 13") LF2895050 8.30" 13.30" 0.50 lbs. ProPEX LF Copper Stub Ell, ½" PEX LF Brass x ½" Copper (13" x 8") LF2855050 13.30" 8.30" 0.50 lbs. ProPEX LF Copper Stub Ell, ¾" PEX LF Brass x ¾" Copper (4" x 8") LF2897575 5.00" 8.00" 0.20 lbs. Installation Refer to the AquaPEX Professional Plumbing Installation Guide for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings ANSI/NSF 14- and 61-certified; HUD MR 1269; ICC ESR 1099; U.P. Code, Annex G Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-1409 www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. 2Visit listing agency’s website for complete information; 3For ½", ¾", 1", 1¼", 1½" and 2" tubing only ProPEX® Ring Submittal information Revision I: Nov. 1, 2018 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer’s representative: Approved by: Technical data Material: Engel-method crosslinked polyethylene (PEX-a) Density: 926 to 940 kg/m3 Degree of crosslinking: 70% to 89% Product information and application use Uponor ProPEX® rings are required to make a proper ProPEX connection.1 The ProPEX ring with stop includes a leading edge chamfer and stop edge.  Description Part number Length I.D. O.D. Weight ProPEX Ring, ⅜" ProPEX Ring with Stop, ½" ProPEX Ring with Stop, ⅝" ProPEX Ring with Stop, ¾" ProPEX Ring with Stop, 1" ProPEX Ring with Stop, 1¼" ProPEX Ring with Stop, 1½" ProPEX Ring with Stop, 2" ProPEX Ring with Stop, 2½" ProPEX Ring with Stop, 3" Q4690302 Q4690512 Q4690625 Q4690756 Q4691000 Q4691250 Q4691500 Q4692000 Q4692500 Q4693000 0.54" 0.63" 0.79" 0.87" 1.10" 1.35" 1.61" 1.97" 2.61" 3.12" 0.49" 0.63" 0.75" 0.88" 1.13" 1.38" 1.63" 2.14" 2.66" 3.16" 0.74" 0.87" 1.00" 1.13" 1.42" 1.66" 1.91" 2.61" 3.25" 3.87" 0.005 lbs. 0.006 lbs. 0.008 lbs. 0.012 lbs. 0.020 lbs. 0.030 lbs. 0.040 lbs. 0.133 lbs. 0.230 lbs. 0.400 lbs. Installation Square cut the Uponor PEX tubing. Remove excess material. Slide the ProPEX ring over the end of the tubing (maximum 1/16" over-hang for rings without stop). When using the ProPEX ring with stop, slide the ring on the tubing with the chamfered edge first until the end of the tubing contacts the stop edge. Expand the tubing and ring. If using the ProPEX Manual Expander Tool, rotate the tool a quarter turn after each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the fitting. Make ProPEX connections at temperatures above 5°F/-15°C. For more information, refer to the Uponor ProPEX Connections Instructional Guide. Listings2 cNSFus-fs3; cNSFus-pw; cNSFus-rfh; cQAIus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC; cQAIus P321 Codes ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada Standards ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; CSA B137.5; CSA B214; UL 18213; ULC/ORD-C199P3 Related applications Contact information PEX-a plumbing systems AquaSAFE fire safety systems Hydronic radiant heating and cooling systems Snow melting systems Turf conditioning systems Permafrost prevention systems Uponor Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739 Fax: 952.891.2008 uponorpro.com Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA Phone: 888.994.7726 Fax: 800.638.9517 uponorpro.com 2018 Design Handbook / 08-2018/ Page 51 located within the dwelling unit and includes individual brass shut-off valves on each branch line or a common shut-off located on the copper supply branch line to the manifold. Shut-off valves and manifolds are to be accessible within the apartment or immediately outside the apartment in a common corridor; use locked access doors in non-mechanical room locations. All pipe, fittings and crimp rings must be part of one manufacturer’s system. Manifolds shall be copper or be part of the manufacturer’s system meeting ASTM F877. 3) There are no connectors, union, or splices, etc., located between the central manifold and the termination stub-out at each fixture. Each fixture stub-out shall be copper pipe secured to the building framing with compatible, heavy-duty, support plates that fastens the support stub-out securely in place. 4) Heating units may be piped as a continuous loop from heating unit to heating unit provided that there are no intervening connections, unions, or splices, etc. 5) All piping shall carry a 25-year manufacturer’s warranty. 6) The connectors shall carry a 2-year manufacturer’s warranty. 7) Connectors shall be brass or bronze with full circle; brass, copper or stainless-steel crimp ring connectors that utilize crimping tools meeting the manufacturer’s specifications. Slip, push-fit, adjustable and cinch type connectors are not allowable. 8) The installing contractor shall provide an installation warranty of 2 years. Systems utilizing PEX-a piping: 1) All piping shall be PEX-a piping from one manufacturer meeting ASTM F876 and F877 certification standards. 2) All fittings shall meet ASTM F1960 standards. 3) Main building supply and return lines may be PEX-a if the installation meets building code requirements including requirements for penetrations into fire rated assemblies. 4) Main building supply and return lines are to utilize metallic fittings. 5) Dwelling units are to be supplied by single branch mains piped from the main supply lines. 6) Within dwelling units, fixtures are to be piped directly from supply manifolds, or multiple line branch tees, meeting the pipe system manufacturer’s requirements. Manifolds with shut-off valves are to be properly supported as necessary for valve operation. Manifolds without shut-offs are to have main branch line shut-offs on supply lines to the manifolds. 7) Multiple line branch tees may be provided if located in an accessible location. 8) Shut-off valves for each apartment branch line are to be accessible within the apartment, or immediately outside the apartment in a common 2018 Design Handbook / 08-2018/ Page 52 corridor. Manifolds and branch tees are to be accessible within the apartment. Use locked access doors in non-mechanical room locations. 9) There are no connectors, union, or splices, etc., located between the central manifold, or multiple line branch tee, and the termination stub-out at each fixture. Each fixture stub-out shall be copper pipe secured to the building framing with compatible, heavy-duty, support plates that fastens the stub-outs securely in place. 10) The entire system shall carry a manufacturer’s 25-year warranty and be installed by plumbers trained in accordance with the manufacturer’s requirements. 11) The installing contractor shall provide an installation warranty of 2 years. 3. Provide drain pans for all hot water tanks, washing machines, etc. 4. All pre-manufactured tubs/shower units are to be at a minimum made of a seamless one-piece molded construction. Pre-manufactured bathtub and shower units in adaptable dwelling units shall be factory reinforced to accept grab bars meeting applicable accessibility requirements. Pre-manufactured bathtub and shower units in adapted locations shall be factory equipped with all required grab bars. 5. Tub/shower fixture handles must be the paddle handle type, single-mixing valve with a scald-proof feature. 6. All tub and shower units are to be provided with a slip resistant finish. 7. For elderly units, provide lever faucet controls for the kitchen sink and bathroom lavatory. 8. For elderly units, provide a hand-held shower head with at least 5 feet of hose on an adjustable bracket. 9. Provide water conserving fixtures as follows: toilets – 1.6 gpf; showerheads – 2.0 gpm; kitchen faucets – 2.2 gpm; bathroom lavatory faucets and all other fixtures in dwelling units and common areas (excluding service sinks) – 1.5 gpm. In addition, projects are encouraged to include EPA WaterSense labeled products. 10. All fixtures shall be connected to vent stacks which extend to above the roof surface. 11. All sprinkler piping shall run in concealed spaces. At top floors, piping shall be protected from freezing by utilizing side wall sprinkler heads at interior partitions or by running piping in dropped soffits that are completely enclosed on all four sides below the thermal envelope. B. HVAC 1. Provide ENERGY STAR labeled heating and cooling equipment, or equivalent. 2. Electric heating systems and electric domestic hot water systems may be permissible when systems meet high energy efficiency criteria noted elsewhere in this handbook, or for limited use in common areas when equipment is compatible with a recognized energy efficiency program in which the project is enrolled. 3. Provide mechanical ventilation for all bathrooms and kitchens. Vent all to exterior with vent hoods. Filtered vents are not acceptable. See additional Range Hood requirements in Section 4.04.11 F&G.