HomeMy WebLinkAbout22 1116 Domestic Water Piping resubmittal REVIEWED AND APPROVEDSubmittal Transmittal
SUBMITTAL TRANSMITTAL
Project Name: Ithaca Arthaus
Project Number : 18260
A Transmittal (from SUBCONTRACTOR)
To:Vecino Construction, LLC Date Submitted
Attn:Corey Olmstead Submittal No. (per Procore)
corey@vecinogroup.com Submitted for Review & Approval REV (0)
Phone: (315) 854-0979
x ReSubmitted for Review & Approval REV (1)
From:Woodcock & Armani
mike.meyer@comfortsystemsusa.com This is a FULL SUBMITTAL
315-701-2042
x This is a PARTIAL Submittal
Item
No.
Dwg. And/or Specification
Section
SpecParagraph /
No.Title / Description Manufacturer Submittal Type Lead Time
1 22 1116 2.2C Domestic water piping (piping within units)Uponor
2
3
4
5
6
7
8
9
10
11
Comments:Vecino Construction Stamp BW A&E Stamp
The pex piping will be within the units,
and be home runs from the manifold
to each fixture
The manifold will have a single valve
on the inlet (not individual branch valves)as allowed by the
2018 NYS HCR Design Handbook(see attached)
Signature/Stamp of Transmitter Date
1ProPEX® is a registered trademark of Uponor Inc. ProPEX™ is a trademark of Uponor Ltd.; 2Visit listing agency’s website for
complete information.
Uponor AquaPEX® red coils and straight lengths
Submittal information
Revision I: Nov. 7, 2018
Project information
Job name:
Location: Part no. ordered:
Engineer: Date submitted:
Contractor: Submitted by:
Manufacturer’s representative: Approved by: Technical data
Material:
Crosslinked polyethylene
PEX-a Engel method; PEX 5306
Standard grade
Hydrostatic ratings (PPI):
200°F at 80 psi (93°C at 5.5 bar)
180°F at 100 psi (82°C at 6.9 bar) 73.4°F at 160 psi (23°C at 11 bar)
Linear expansion rate: 1.10"/10°F/100' (27.94mm/5.56°C/30.48m)
Product information and application use
Uponor AquaPEX® red tubing is used primarily for hot potable-water distribution, but can also be used in radiant heating and cooling
systems containing no ferrous corrodible components or where ferrous components are isolated from the tubing.
Description Part number I.D. O.D. Weight
½" Uponor AquaPEX Red, 100-ft. coil
½" Uponor AquaPEX Red, 300-ft. coil
½" Uponor AquaPEX Red, 1,000-ft. coil
¾" Uponor AquaPEX Red, 100-ft. coil
¾" Uponor AquaPEX Red, 300-ft. coil
¾" Uponor AquaPEX Red, 500-ft. coil
1" Uponor AquaPEX Red, 100-ft. coil
1" Uponor AquaPEX Red, 300-ft. coil
1" Uponor AquaPEX Red, 500-ft. coil
½" Uponor AquaPEX Red, 20-ft. straight length, 500 ft.
¾" Uponor AquaPEX Red, 20-ft. straight length, 300 ft.
1" Uponor AquaPEX Red, 20-ft. straight length, 200 ft.
F2040500
F2060500
F2120500
F2040750
F2060750
F2100750
F2041000
F2061000
F2101000
F2930500
F2930750
F2921000
0.475"
0.475"
0.475"
0.671"
0.671"
0.671"
0.862"
0.862"
0.862"
0.475"
0.671"
0.862"
0.625"
0.625"
0.625"
0.875"
0.875"
0.875"
1.125"
1.125"
1.125"
0.625"
0.875"
1.125"
6 lbs.
18 lbs.
54 lbs.
10 lbs.
34 lbs.
54 lbs.
20 lbs.
56 lbs.
93 lbs.
28 lbs.
31 lbs.
35 lbs.
Installation
Approved fitting system is ProPEX®1. Refer to the Uponor ProPEX Connections Instructional Guide, the Uponor Professional Plumbing Installation Guide or the Uponor Piping Pocket Guide for more information.
Listings2
cNSFus-pw; cQAIus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC
Codes
ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada
Standards
ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2;
ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; AWWA C904; CSA B137.5; CSA B214
Related applications Contact information
PEX-a plumbing systems
Radiant heating and cooling systems
Uponor Inc.
5925 148th Street West Apple Valley, MN 55124 USA T 800.321.4739
F 952.891.2008 uponorpro.com
Uponor Ltd.
6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA T 888.994.7726
F 800.638.9517 uponorpro.com
1ProPEX® is a registered trademark of Uponor Inc. ProPEX™ is a trademark of Uponor Ltd.; 2Visit listing agency’s website for complete information.
Uponor AquaPEX® blue coils and straight lengths
Submittal information
Revision I: Nov. 7, 2018
Project information
Job name:
Location: Part no. ordered:
Engineer: Date submitted:
Contractor: Submitted by:
Manufacturer’s representative: Approved by: Technical data
Material:
Crosslinked polyethylene
PEX-a Engel method; PEX 5306
Standard grade hydrostatic ratings (PPI):
200°F at 80 psi (93°C at 5.5 bar) 180°F at 100 psi (82°C at 6.9 bar)
73.4°F at 160 psi (23°C at 11 bar) Linear expansion rate: 1.10"/10°F/100' (27.94mm/5.56°C/30.48m)
Product information and application use
Uponor AquaPEX® blue tubing is used primarily in cold potable-water distribution systems, but can also be used in radiant heating
and cooling systems containing no ferrous corrodible components or where ferrous components are isolated from the tubing.
Description Part number I.D. O.D. Weight
½" Uponor AquaPEX Blue, 100-ft. coil
½" Uponor AquaPEX Blue, 300-ft. coil
½" Uponor AquaPEX Blue, 1,000-ft. coil
¾" Uponor AquaPEX Blue, 100-ft. coil
¾" Uponor AquaPEX Blue, 300-ft. coil
¾" Uponor AquaPEX Blue, 500-ft. coil
1" Uponor AquaPEX Blue, 100-ft. coil
1" Uponor AquaPEX Blue, 300-ft. coil
1" Uponor AquaPEX Blue, 500-ft. coil
½" Uponor AquaPEX Blue, 20-ft. straight length, 500 ft.
¾" Uponor AquaPEX Blue, 20-ft. straight length, 300 ft.
1" Uponor AquaPEX Blue, 20-ft. straight length, 200 ft.
F3040500
F3060500
F3120500
F3040750
F3060750
F3100750
F3041000
F3061000
F3101000
F3930500
F3930750
F3921000
0.475"
0.475"
0.475"
0.671"
0.671"
0.671"
0.862"
0.862"
0.862"
0.475"
0.671"
0.862"
0.625"
0.625"
0.625"
0.875"
0.875"
0.875"
1.125"
1.125"
1.125"
0.625"
0.875"
1.125"
6 lbs.
18 lbs.
54 lbs.
10 lbs.
34 lbs.
54 lbs.
20 lbs.
56 lbs.
93 lbs.
28 lbs.
31 lbs.
35 lbs.
Installation
Approved fitting system is ProPEX®1. Refer to the Uponor ProPEX Connections Instructional Guide, the Uponor Professional Plumbing Installation Guide or the Uponor Piping Pocket Guide for more information.
Listings2
cNSFus-pw; cQAIus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC
Codes
ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada
Standards
ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; AWWA C904; CSA B137.5; CSA B214
Related applications Contact information
PEX-a plumbing systems
Radiant heating and cooling systems
Uponor Inc.
5925 148th Street West Apple Valley, MN 55124 USA T 800.321.4739 F 952.891.2008 uponorpro.com
Uponor Ltd.
6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA T 888.994.7726 F 800.638.9517 uponorpro.com
1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd.
1" Branch Manifold with ½" ProPEX® Lead-free (LF) Outlets
Submittal information
Revision B: Aug. 2, 2017
Project information
Job name:
Location: Part no. ordered:
Engineer: Date submitted:
Contractor: Submitted by:
Manufacturer’s representative: Approved by:
Technical data
Material: Type L copper; C69300 brass
Maximum temperature (no pressure): 320°F (160°C)
Maximum working temperature/pressure: 210°F at 150 psi (99°C at 10 bar)
Maximum flow rate at 5 fps: 12.8 gpm Maximum flow rate at 8 fps: 20.5 gpm
Product information and application use
The Uponor 1" Copper Branch Manifold with ½" ProPEX® Lead-free (LF) Outlets is used for hot and cold domestic potable-water distribution systems.1 The manifold has a 1" copper sweat fitting adapter supply connection. All outlets are configured with ½" ProPEX LF brass connections.
Description Part number A B C D Weight
1" Branch Manifold with ½" ProPEX LF outlets, 4 outlets LF2801050 8.95" 2.40" 1.50" ½" 0.80 lbs.
1" Branch Manifold with ½" ProPEX LF outlets, 6 outlets LF2811050 11.95" 2.40" 1.50" ½" 1.10 lbs.
1" Branch Manifold with ½" ProPEX LF outlets, 8 outlets LF2821050 14.95" 2.40" 1.50" ½" 1.40 lbs.
1" Branch Manifold with ½" ProPEX LF outlets, 10 outlets LF2831050 17.95" 2.40" 1.50" ½" 1.70 lbs.
1" Branch Manifold with ½" ProPEX LF outlets, 12 outlets LF2841050 20.95" 2.40" 1.50" ½" 1.90 lbs.
Installation
Use any product designed to mount 1" copper pipe as a mounting bracket. Any bend within 6 inches of the ProPEX connection to the manifold requires the use of a Tube Talon (F7050750) or Bend Support (A5110500 and A5150500). Refer to the Uponor Commercial Piping Pocket Guide, Uponor AquaSAFE™ Residential Fire Sprinkler Installation Guide or the Uponor Radiant Installation Handbook for additional information.
Standards
CAN/CSA B137.5; ASTM F877; ASTM F1960
Codes
IPC; UPC; NSPC; NPC of Canada
Listings
ICC ESR 1099; ANSI/NSF 14- and 61-certified; IAPMO; U.P. Code, Annex G
Related applications Contact information
PEX-a plumbing systems Residential fire safety systems Radiant heating and cooling systems
Uponor Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739
Fax: 952.891.2008 uponorpro.com
Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA Phone: 888.994.7726
Fax: 800.638.9517 uponorpro.com
ProPEX® Lead-free Copper Stub Ell, PEX LF Brass x Copper
Submittal Information
Revision A: Jan. 27, 2010
Project Information
Job Name:
Location: Part No. Ordered:
Engineer: Date Submitted:
Contractor: Submitted By:
Manufacturer’s Representative: Approved By:
Technical Data
Material: C69300 Brass; Type L Copper
Product Information and Application Use
The Uponor ProPEX® Lead-free Copper Stub Ell provides a 90° transition from Uponor AquaPEX® tubing to copper.1
The copper stub ell is comprised of ½" copper pipe with an Uponor
ProPEX Fitting on one end and the other end spun closed.
9 Description Part Number A B Weight
ProPEX LF Copper Stub Ell, ½" PEX LF Brass x ½" Copper (3½" x 8") LF2865050 4.75" 8.30" 0.20 lbs.
ProPEX LF Copper Stub Ell, ½" PEX LF Brass x ½" Copper (8" x 13") LF2895050 8.30" 13.30" 0.50 lbs.
ProPEX LF Copper Stub Ell, ½" PEX LF Brass x ½" Copper (13" x 8") LF2855050 13.30" 8.30" 0.50 lbs.
ProPEX LF Copper Stub Ell, ¾" PEX LF Brass x ¾" Copper (4" x 8") LF2897575 5.00" 8.00" 0.20 lbs.
Installation
Refer to the AquaPEX Professional Plumbing Installation Guide for additional information.
Standards
CAN/CSA B137.5; ASTM F877; ASTM F1960
Codes
IPC; UPC; NSPC; NPC of Canada
Listings
ANSI/NSF 14- and 61-certified; HUD MR 1269; ICC ESR 1099; U.P. Code, Annex G
Related Applications Contact Information
PEX-a Plumbing Systems Uponor, Inc. 5925 148th Street West
Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-1409 www.uponor-usa.com
Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200
Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca
1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd.
1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. 2Visit listing agency’s website for complete information; 3For ½", ¾", 1", 1¼", 1½" and 2" tubing only
ProPEX® Ring
Submittal information
Revision I: Nov. 1, 2018
Project information
Job name:
Location: Part no. ordered:
Engineer: Date submitted:
Contractor: Submitted by:
Manufacturer’s representative: Approved by:
Technical data
Material: Engel-method crosslinked polyethylene (PEX-a)
Density: 926 to 940 kg/m3
Degree of crosslinking: 70% to 89%
Product information and application use
Uponor ProPEX® rings are required to make a proper ProPEX connection.1 The ProPEX ring with stop includes a leading edge chamfer and stop edge.
Description Part number Length I.D. O.D. Weight
ProPEX Ring, ⅜"
ProPEX Ring with Stop, ½"
ProPEX Ring with Stop, ⅝"
ProPEX Ring with Stop, ¾"
ProPEX Ring with Stop, 1"
ProPEX Ring with Stop, 1¼"
ProPEX Ring with Stop, 1½"
ProPEX Ring with Stop, 2"
ProPEX Ring with Stop, 2½"
ProPEX Ring with Stop, 3"
Q4690302
Q4690512
Q4690625
Q4690756
Q4691000
Q4691250
Q4691500
Q4692000
Q4692500
Q4693000
0.54"
0.63"
0.79"
0.87"
1.10"
1.35"
1.61"
1.97"
2.61"
3.12"
0.49"
0.63"
0.75"
0.88"
1.13"
1.38"
1.63"
2.14"
2.66"
3.16"
0.74"
0.87"
1.00"
1.13"
1.42"
1.66"
1.91"
2.61"
3.25"
3.87"
0.005 lbs.
0.006 lbs.
0.008 lbs.
0.012 lbs.
0.020 lbs.
0.030 lbs.
0.040 lbs.
0.133 lbs.
0.230 lbs.
0.400 lbs.
Installation
Square cut the Uponor PEX tubing. Remove excess material. Slide the ProPEX ring over the end of the tubing (maximum 1/16" over-hang for rings without stop). When using the ProPEX ring with stop, slide the ring on the tubing with the chamfered edge first until the end of the tubing contacts the stop edge. Expand the tubing and ring. If using the ProPEX Manual Expander Tool, rotate the tool a quarter turn after each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the fitting. Make ProPEX connections at temperatures above 5°F/-15°C. For more information, refer to the Uponor ProPEX Connections Instructional Guide.
Listings2
cNSFus-fs3; cNSFus-pw; cNSFus-rfh; cQAIus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC; cQAIus P321
Codes
ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada
Standards
ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; CSA B137.5; CSA B214; UL 18213; ULC/ORD-C199P3
Related applications Contact information
PEX-a plumbing systems AquaSAFE fire safety systems Hydronic radiant heating and cooling systems Snow melting systems Turf conditioning systems Permafrost prevention systems
Uponor Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739 Fax: 952.891.2008 uponorpro.com
Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA Phone: 888.994.7726 Fax: 800.638.9517 uponorpro.com
2018 Design Handbook / 08-2018/ Page 51
located within the dwelling unit and includes individual brass shut-off
valves on each branch line or a common shut-off located on the copper
supply branch line to the manifold. Shut-off valves and manifolds are to be
accessible within the apartment or immediately outside the apartment in a
common corridor; use locked access doors in non-mechanical room
locations. All pipe, fittings and crimp rings must be part of one
manufacturer’s system. Manifolds shall be copper or be part of the
manufacturer’s system meeting ASTM F877.
3) There are no connectors, union, or splices, etc., located between the
central manifold and the termination stub-out at each fixture. Each fixture
stub-out shall be copper pipe secured to the building framing with
compatible, heavy-duty, support plates that fastens the support stub-out
securely in place.
4) Heating units may be piped as a continuous loop from heating unit to
heating unit provided that there are no intervening connections, unions, or
splices, etc.
5) All piping shall carry a 25-year manufacturer’s warranty.
6) The connectors shall carry a 2-year manufacturer’s warranty.
7) Connectors shall be brass or bronze with full circle; brass, copper or
stainless-steel crimp ring connectors that utilize crimping tools meeting the
manufacturer’s specifications. Slip, push-fit, adjustable and cinch type
connectors are not allowable.
8) The installing contractor shall provide an installation warranty of 2 years.
Systems utilizing PEX-a piping:
1) All piping shall be PEX-a piping from one manufacturer meeting ASTM F876
and F877 certification standards.
2) All fittings shall meet ASTM F1960 standards.
3) Main building supply and return lines may be PEX-a if the installation meets
building code requirements including requirements for penetrations into
fire rated assemblies.
4) Main building supply and return lines are to utilize metallic fittings.
5) Dwelling units are to be supplied by single branch mains piped from the
main supply lines.
6) Within dwelling units, fixtures are to be piped directly from supply
manifolds, or multiple line branch tees, meeting the pipe system
manufacturer’s requirements. Manifolds with shut-off valves are to be
properly supported as necessary for valve operation. Manifolds without
shut-offs are to have main branch line shut-offs on supply lines to the
manifolds.
7) Multiple line branch tees may be provided if located in an accessible
location.
8) Shut-off valves for each apartment branch line are to be accessible within
the apartment, or immediately outside the apartment in a common
2018 Design Handbook / 08-2018/ Page 52
corridor. Manifolds and branch tees are to be accessible within the
apartment. Use locked access doors in non-mechanical room locations.
9) There are no connectors, union, or splices, etc., located between the
central manifold, or multiple line branch tee, and the termination stub-out
at each fixture. Each fixture stub-out shall be copper pipe secured to the
building framing with compatible, heavy-duty, support plates that fastens
the stub-outs securely in place.
10) The entire system shall carry a manufacturer’s 25-year warranty and be
installed by plumbers trained in accordance with the manufacturer’s
requirements.
11) The installing contractor shall provide an installation warranty of 2 years.
3. Provide drain pans for all hot water tanks, washing machines, etc.
4. All pre-manufactured tubs/shower units are to be at a minimum made of a seamless
one-piece molded construction. Pre-manufactured bathtub and shower units in
adaptable dwelling units shall be factory reinforced to accept grab bars meeting
applicable accessibility requirements. Pre-manufactured bathtub and shower units in
adapted locations shall be factory equipped with all required grab bars.
5. Tub/shower fixture handles must be the paddle handle type, single-mixing valve with a
scald-proof feature.
6. All tub and shower units are to be provided with a slip resistant finish.
7. For elderly units, provide lever faucet controls for the kitchen sink and bathroom
lavatory.
8. For elderly units, provide a hand-held shower head with at least 5 feet of hose on an
adjustable bracket.
9. Provide water conserving fixtures as follows: toilets – 1.6 gpf; showerheads – 2.0
gpm; kitchen faucets – 2.2 gpm; bathroom lavatory faucets and all other fixtures in
dwelling units and common areas (excluding service sinks) – 1.5 gpm. In addition,
projects are encouraged to include EPA WaterSense labeled products.
10. All fixtures shall be connected to vent stacks which extend to above the roof surface.
11. All sprinkler piping shall run in concealed spaces. At top floors, piping shall be
protected from freezing by utilizing side wall sprinkler heads at interior partitions or
by running piping in dropped soffits that are completely enclosed on all four sides
below the thermal envelope.
B. HVAC
1. Provide ENERGY STAR labeled heating and cooling equipment, or equivalent.
2. Electric heating systems and electric domestic hot water systems may be permissible
when systems meet high energy efficiency criteria noted elsewhere in this handbook,
or for limited use in common areas when equipment is compatible with a recognized
energy efficiency program in which the project is enrolled.
3. Provide mechanical ventilation for all bathrooms and kitchens. Vent all to exterior
with vent hoods. Filtered vents are not acceptable. See additional Range Hood
requirements in Section 4.04.11 F&G.