HomeMy WebLinkAbout23 05 12-1.1 Fan Submittal Rev. 2 - APPROVED AS NOTED2 Vecino Construction, LLC (Contractor Review) Recommend Approval Recommend Approval as Noted Revise and Resubmit Reviewed for general conformance with the Contract Documents. Subcontractor or material supplier is responsible for: confirming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating his work with that of all other trades; and performing his work in a safe and satisfactory manner. Project: Reviewed by: Date: Corey Olmstead 18260 Ithaca Arthaus 12/17/2020 Evan Hallas 12/28/2020 EF-2 shall be controlled by 2-hour timer per Fan Schedule on M001. It is unclear if controller selected has timer function. X D.D.1/4/21 Provide all accessories as per schedule. Tag: Project:Ithaca Arthaus Office: Version:2014.0.487 Quantity: 1 Special:None Dimensions Standard Construction Features • Two (2) patented wheel designs • Round mounting base • Popular direct drive sizes use multi-speed motors for maximum flexibility • Direct drive (Open/TE) motors include overload protection as standard • Plug-Disconnect and pre-wired junction box (1-speed ODP motors up to 3/4 HP) Accessories Application: E - Exhaust Drive Type: D - Direct Efficiency: G - Green Plus ECM Motor Tap: R Unit Size E H L Wo Controllers: 3 - Multi speed ctrlr iQ-MS (ECM only) 16 24 24.25 30.75 16 Service Switches and ITW: C - NEMA 1 - mounted and wired Special Construction: C - Spark Resistance (AMCA C) Weight Guard/Screen: B - Bird Screen 69 Damper Type: A1 - Alum Prllel Bld Dmpr, mtrzd 115V Performance 800 0.5 1135 0.137 0 70 N/A * NEC FLA - based on tables 430.248 or 430.250 of National Electrical Code 2014. Actual motor FLA may vary depending on motor manufacturer. + Motor weight may vary depending on supplier WFX16RGP Wall Mounted Upblast Spun Aluminum Exhaust Fan Operating Point Volume (CFM) Static Pressure (in. wg) Fan RPM Horse Power (BHP) Elevation (ft) Temperature (°F) Drive Loss (%) EF-2 Northeast HVAC Solutio Page 1 of 2 - Edge Version 2014.0.487 - Product Information is Subject to Change without Notice Enclosure 3 - ODP w/Overload NEC FLA*3.6 Weight+ (lbs)C/F Motor Information Motor HP 0.33 - 1/3 HP Volt/Ph/Hz 230V/1PH/60HZ VC Note: to be provided per notes on previous returned submittal. Tag: Project:Ithaca Arthaus Office: Version:2014.0.487 (continued) 63 125 250 500 1000 2000 4000 8000 63 70 70 61 58 56 49 41 LwA - Weighted sound power, based on ANSI S1.4, dBA - Weighted sound pressure, based on 65 53.9 6.9 11.5 dB attenuation per Octave band at 5 ft. Sones - calculated using AMCA 301 at 5 ft. SOUND POWER OCTAVE POWER CENTER FREQUENCY (hz) Page 2 of 2 - Edge Version 2014.0.487 - Product Information is Subject to Change without Notice LWA Dba Sones EF-2 Northeast HVAC Solutio Tag: Project:Ithaca Arthaus Office: Version:2014.0.487 Quantity: 1 Special:None Product Image Motorized 115V (MD1) •110V damper actuator for positive opening and closing. •Square galvanized steel frame, •Multi-leaf, roll formed aluminum blades; with •Nylon bearings; and •Felt Edges for quiet operation Options or Accessories Listing 0 - Not an accessory L - Light E - Exhaust Schedule ID Quantity Tag 11EF-2 EF-2 Northeast HVAC Solutions Page 1 of 1 - Edge Version 2014.0.487 - Product Information is Subject to Change without Notice Motorized 115V (MD1) Motor Operated Back Draft Damper Model Parent Duty Application