Loading...
HomeMy WebLinkAbout23 05 12 - 11 Pipe InsulationSUBMITTAL TRANSMITTAL Project Name: Ithaca Arthaus Project Number : 18260 A To: Vecino Construction, LLC Date Submitted Attn:Submittal No. (per Procore) X From: Item No. Spec Paragraph / No.Submittal Type Lead Time 1 Product Information 2 3 4 5 6 7 8 9 10 11 Comments: Date 23 05 12 - 11 Transmittal (from SUBCONTRACTOR) 23 31 13 mcahill@suretemp.com Streamline Manufacturer 2/17/2021 Maura Cahill Dwg. And/or Specification Section Pipe Insulation Title / Description ReSubmitted for Review & Approval REV (1) Submitted for Review & Approval REV (0) This is a FULL SUBMITTAL This is a PARTIAL Submittal Corey Olmstead corey@vecinogroup.com Phone: (315) 854-0979 Signature/Stamp of Transmitter Vecino Construction Stamp BW A&E Stamp Submittal Transmittal Vecino Construction, LLC (Contractor Review) Recommend Approval Recommend Approval as Noted Revise and Resubmit Reviewed for general conformance with the Contract Documents. Subcontractor or material supplier is responsible for: confirming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating his work with that of all other trades; and performing his work in a safe and satisfactory manner. Project: Reviewed by: Date: Corey Olmstead 18260 Ithaca Arthaus 2/18/21 Distributed by Mueller Streamline Co. • 150 Schilling Blvd, Suite 201, Collierville, Tennessee 38017 • 1-800-348-8464 • www.muellerstreamline.com page 1 of 4 Product Description: Streamline® Standard and Mini Split Line Sets are available in either an elastomeric or coated elastomeric insulation for use in HVACR applications. All line sets will be manufactured in the United States. Material: Streamline® Standard and Mini Split Line Sets copper tube shall be made from C12200 grade of copper. Insulation is choice of elastomeric or coated elastomeric material. Elastomeric insulation has a UV retardant added but it is recommended to cover or apply a coating for long term exposure. Coated elastomeric insulation utilizes a co-extruded jacket that requires no additional cover or coating. Key Specifications: Streamline® Standard and Mini Split Line Sets are made to meet the requirements of ASTM B1003. Streamline® Standard and Mini Split Line Sets are third party verified in select sizes through Underwriters Laboratories (UL) for operating pressure of 700psi at 250°F. This rating includes fully annealed and brazed copper tubing. Installation: Installations and insulation material shall comply with the latest applicable building codes for the local jurisdiction. For elastomeric insulation, it is recommended, at minimum, to coat insulation on exterior applications with 2 coats of WB Finish a (recoat every 2-4 years). For more substantial protection, place in a protective jacket or protective channel. In accordance with ASTM instructions, insulation ends must be sealed to prevent air/moisture intrusion. Both ends of the tube should be taped with 2” wide Polyken-936-30 tape or equivalent (high U.V. Resistant/High tack joint wrap tape). Reference local building codes for additional details. References: Product Line Product Type Outer Diameter Copper Tube Streamline® Refrigeration Service Coils Streamline® Line Sets & Mini-Splits Streamline® ACR - Type L (Hard Lengths) Streamline® ACR - Type K (Hard Lengths) 1/8” – 1-1/8” 1/4” – 1-1/8” 1/4” – 1-3/8” 1/4” – 2-5/8” STANDARD AND MINI SPLIT LINE SETS FOR HVACR APPLICATIONS Job Name Contractor Job Location Wholesaler Engineer Streamline® Rep MADE IN USA Distributed by Mueller Streamline Co. • 150 Schilling Blvd, Suite 201, Collierville, Tennessee 38017 • 1-800-348-8464 • www.muellerstreamline.com page 2 of 4 STANDARD AND MINI SPLIT LINE SET DATA STANDARD LINE SETS WITH ELASTOMERIC INSULATION Copper Tube Sizes Lengths Insulation Thickness Optional FinishesLiquid Line Suction Line 1/4" - 1/2"3/8" - 1-1/8"10' - 50' using 5' intervals; 60' & 100' (other lengths are available upon customer request)3/8" - 1" Flare nuts, 90-degree bends, custom connections, thermostat wire and taping MINI SPLIT LINE SETS WITH ELASTOMERIC INSULATION Copper Tube Sizes Lengths Insulation Thickness Optional FinishesLiquid Line Suction Line 1/4" - 3/8"3/8" - 3/4" 15' - 50' using 5' intervals; 100' (other lengths are available upon customer request) 3/8" - 1" Insulated liquid and suction lines and twin tube system, flare nuts, 90-degree bends, custom connections, mini-split wire or control cable and taping DURAGUARD UV™ LINE SETS WITH COATED ELASTOMERIC INSULATION Copper Tube Sizes Lengths Insulation Thickness Optional FinishesLiquid Line Suction Line 1/4" - 1/2"3/8" - 7/8"25', 35' & 50'1/2" - 1" Insulated liquid and suction lines, flare nuts, 90-degree bends, mini-split wire or control cable and taping Distributed by Mueller Streamline Co. • 150 Schilling Blvd, Suite 201, Collierville, Tennessee 38017 • 1-800-348-8464 • www.muellerstreamline.com page 3 of 4 ELASTOMERIC INSULATION SPECIFICATION* INSULATION: "R" Values Pipe Insulation ID Size Nom. 3/8"Nom. 1/2"Nom. 3/4"Nom. 1" 1/4"2.8 3.8 6.4 8.3 3/8"2.8 3.3 5.9 7.2 1/2"2.6 3.3 5.5 7.2 5/8"2.6 3.4 5.6 7.0 3/4"2.4 3.3 5.5 7.0 7/8"2.4 3.3 5.4 7.0 1-1/8"2.2 3.3 5.4 7.2 SPECIFICATION COMPLIANCE •ASTM B1003 •ASTM C 534, Type II — Sheet Grade 1 •ASTM C 1534 •ASTM E 84, NFPA 255, UL 723 •CAN/ULC S102 •NFPA 90A, 90B •ASTM G21/C1338 •ASTM G22 •ASTM D 1056, 2B1 •MIL-P-15280J, FORM S •MIL-C-3133C (MIL STD 670B), •Grade SBE 3 •MEA 107-89M •UL 181 •UL 94 5V-A, V-0, File E 55798 •City of Los Angeles – RR 7642 •ASTM D 1149 PHYSICAL PROPERTIES Specifications Values Test Method Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F Mean Temperature (24°C) 90°F Mean Temperature (32°C) 0.245 (0.035) 0.254 (0.037)ASTM C 177 or C 518 Water Vapor Permeability, Perm-in. [Kg/(s•m•Pa)]0.05 (0.725 x 10–13)ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 1” (25mm)*25/50* ASTM E 84 CAN/ULC S102 Mold Growth Fungi Resistance Bacterial Resistance UL181 ASTM G21/C1338 ASTM G22 Meets requirements Meets requirements Meets requirements Water Absorption, % by Volume 0.2%ASTM C 209 Upper Use Limit 220°F (105°C)**ASTM C 534 Lower Use Limit -297°F (-183°C)**ASTM C 534 Ozone Resistance GOOD Ozone Chamber Test *Mueller Streamline does not independently verify the following information provided by its vendors and makes no representation to the accuracy or completeness of information. Distributed by Mueller Streamline Co. • 150 Schilling Blvd, Suite 201, Collierville, Tennessee 38017 • 1-800-348-8464 • www.muellerstreamline.com page 4 of 4 COATED ELASTOMERIC INSULATION SPECIFICATION* INSULATION: "R" Values Pipe Insulation ID Size Nom. 1/2"Nom. 3/4"Nom. 1" 1/4"4.0 6.1 9.6 3/8"3.6 5.6 8.5 1/2"3.4 5.4 7.9 5/8"3.3 5.4 7.5 3/4"3.1 5.4 7.5 7/8"3.2 5.4 7.2 1-1/8"3.1 5.5 7.1 SPECIFICATION COMPLIANCE •ASTM B1003 •ASTM C 534, Type I — Tubular, Grade 1 •ASTM E 84, NFPA 255, UL 723 •NFPA 90A, 90B •ASTM G21/C1338 •ASTM G22 •ASTM D 1056, 2B1 •MIL-P-15280J, FORM S •MIL-C-3133C (MIL STD 670B), •UL 94 5V-A, V-0, HF-I (File E 300774) •2012, 2015, 2018 IECC, IMC, IRC •2016 CA Title 24, Part 6, Subchapter 3, Section 120.3 •RoHS Compliant PHYSICAL PROPERTIES Specifications Values Test Method Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F Mean Temperature (24°C)0.242 (0.035)ASTM C 177 or C 518 Water Vapor Permeability,<0.01 perm-in. insulation ≤0.05 perms jacket ASTM E 96 Flame Spread and Smoke Developed Index through 1-1/2” (37.5mm)25/50 ASTM E 84 Mold Growth Fungi Resistance Bacterial Resistance UL181 ASTM G21/C1338 ASTM G22 Meets requirements Meets requirements Meets requirements Water Absorption, % by Volume 0%ASTM C 209 Upper Use Limit 220°F (104°C)**ASTM C 534 Lower Use Limit -297°F (-183°C)**ASTM C 534 Hot Surface Performance 250°F ASTM C411, NFPA 90A Meets requirements UV Resistance (Artificial Aging) ASTM G153 Meets requirements *Mueller Streamline does not independently verify the following information provided by its vendors and makes no representation to the accuracy or completeness of information.