Loading...
HomeMy WebLinkAbout28 31 11 .2 .3 Fire Alarm Shops and Plans Submittal_REVIEWED AND APPROVEDSUBMITTAL TRANSMITTAL Project Name: Ithaca Arthaus Project Number : 18260 A To: Vecino Construction, LLC Date Submitted Attn:Submittal No. (per Procore) From: X Item No. Spec Paragraph / No.Submittal Type Lead Time 1 -3 4 weeks 2 -2 4 weeks 3 4 5 6 7 8 9 10 11 Comments: DateSignature/Stamp of Transmitter Vecino Construction Stamp BW A&E Stamp 7/24/2020 John Orr Dwg. And/or Specification Section Digital, Addressable Fire-Alarm System Shops Title / Description ReSubmitted for Review & Approval REV (1) Submitted for Review & Approval REV (0) This is a FULL SUBMITTAL This is a PARTIAL Submittal Corey Olmstead corey@vecinogroup.com Phone: (315) 854-0979 (315) 715-1677 Edwards Manufacturer Digital, Addressable Fire-Alarm System Plans 28 31 11-3,2 Transmittal (from SUBCONTRACTOR) 28 31 11 28 31 11 jorr@demcony.com Edwards Submittal Transmittal AEL 8/3/20 2 #16 AWGSLC CIRCUIT #12 # 14 AWGWEATHERPROOFHORN/STROBEP2RKAT FIRE DEPT. CONNECTION24VDC NAC CIRCUIT2 # 14 AWGEARTH GROUNDDEDICATED 120VACPOWER FEEDTO TELEPHONEEQUIPMENTDEMARCATION BLOCK(1) CAT 5 CABLE3 #12AWG1 #12AWGENABLEGAMEWELL/FCI SLP-BLK FIRE ALARM PANEL14 1/8"W x 20 1/8"H x 4 1/2"DLOCATED IN ELECTRICALINSTRUMENTSFIRE CONTROLby HoneywellGamewellPROVIDE DUPLEXRECEPTACLE WITHIN 3FEET OF PANELEOL75WPADDRESSABLE PULLSTATIONMS-7AFMECH 106GAMEWELL/FCI E3BB-FLUSH-LCD ANNUNCIATOR13 1/4"W x 10"H x 3 1/2"DLOCATED IN FIRST FLOORVESTIBULE 1002 #14 AWG(2) SEPARATE PAIR #18 AWG TWISTED/UNSHIELDEDSSU00506 BATTERY CABINET17"W X 8"H X 4"DHOUSES (2) FCI 12V 18ASTAND BY BATTERIESNOTE: ACTUAL BATTER SIZE TO BE VERIFIEDFOLLOWING STAND BY BATTERY CALCULATIONS1" CONDUIT CONNECTIONGENERAL NOTES;1. SHIELDED CABLE SHALL NOT BE USED ON ANY CIRCUITS AS ITRELATES TO THIS FIRE DETECTION SYSTEM UNLESS OTHERWISE NOTED.2. ALL FIRE ALARM CABLING MUST BE INSTALLED A MINIMUM OF1' FROM ALL OTHER HIGH VOLTAGE, LOW VOLTAGE, & TELECOM CABLINGAND A MINIMUM OF 3' FROM ANY BUILDING LIGHTING BALLASTS.3. A TYPICAL SLC INITIATING CIRCUIT MAY HAVE UP TO 159 SENSORSTYLE DEVICES (SMOKE/HEATS/DUCT DETECTORS) AND 159MODULE STYLE DEVICES (PULL STATIONS, MODULES,CONTROL & INPUT MODULES).4. POLARITY MUST BE OBSERVED ON ALL CIRCUITS.5. E.C. TO ENSURE AUDIO SELECT DIAL IS SET AT "2" ANDCANDELA SELECTION DIAL IS SET ACCORDING TO VALUESSHOWN ON RISER DRAWING PRIOR TO INSTALLATIONSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEMECHANICALSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEMECHANICALSPSMOKE DETECTORASD-PL3 W/ B300-6 BASELOBBYSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTORAGE 110SPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEVESTIBULE 107SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEMECH 106WFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESUPPORTIVE SVCS 105SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEPROPERTY MNGR104SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEPROPERTY MNGR104SPSMOKE DETECTORASD-PL3 W/ B300-6 BASECONFERENCE 102WFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLEOLEOLWFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLWFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLWFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLADDRESSABLE INPUTMODULEAMM-2FMECH 1062 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLSPSMOKE DETECTORASD-PL3 W/ B300-6 BASELOBBYAOMADDRESSABLE RELAYMODULEAOM-2RF W/ MR101/CRELAY IN CABINET FORELEVATOR 1 SHUNT TRIP2 #16 AWGMRAUX POWER2 # 14 AWGAOMADDRESSABLE RELAYMODULEAOM-2RF W/ MR101/CRELAY IN CABINET FORELEVATOR 2 SHUNT TRIP2 #16 AWGMR2 #12 AWGW/ GROUND120 VAC FEED FORSHUNT TRIP BREAKER2 #12 AWGW/ GROUND2 #12 AWGW/ GROUNDADDRESSABLE INPUTMODULEAMM-2FTO MONITOR 120VAC TOSHUNT TRIP RELAYS2 #16 AWGAMMPMPOWERSUPERVISION RELAYPAM1ADDRESSABLE INPUTMODULEAMM-2FTO MONITOR 24VDC TOSHUNT TRIP RELAYSAMMPM2 #16 AWGEOLEOL2 #12 AWGW/ GROUNDTO ELEVATORSHUNT TRIPBREAKER (BYOTHERS)2 #12 AWGW/ GROUNDTO ELEVATORSHUNT TRIPBREAKER (BYOTHERS)SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEVESTIBULE 100HFHEAT DETECTORATD-L3 W/ B300-6 BASEELEVATOR PITSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTORAGE 113SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEGALLERY 114SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEGALLERY 114SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEGALLERY 114SPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTUDIO 113SPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTUDIO 113SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEBREAKROOM 115SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEGALLERY OFFICE 116SPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 3SPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 2WFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTORAGE 152SPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFINESS 155SPSMOKE DETECTORASD-PL3 W/ B300-6 BASECOMMUNITY ROOM 151SPSMOKE DETECTORASD-PL3 W/ B300-6 BASECOMMUNITY ROOM 151WFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FSTAIR 12 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FSTAIR 12 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 1HFHEAT DETECTORATD-L3 W/ B300-6 BASEELEVATOR PITUP TOSECOND FLOORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 1SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEELEVATOR LOBBYSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTORAGE 209SPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASELAUNDRY 213SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEELEC 217ADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 2172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 2172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 2172 #16 AWGAMMTO HPF902ULADABOOSTER PANELSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 2WFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 3SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEELEVATOR LOBBY2 #16 AWGSLC CIRCUIT #2SPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOOR NORTHELEV LOBBYSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 3SPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEELEC 317ADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 3172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 3172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 3172 #16 AWGAMMSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 2WFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLSPSMOKE DETECTORASD-PL3 W/ B300-6 BASELAUNDRY 313SPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTORAGE 309SPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORELEV LOBBYSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 1UP TOFOURTH FLOORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETHIRD FLOORELEV LOBBYSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 1SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTORAGE 409SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASELAUNDRY 313SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEELEC 417ADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 4172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 4172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 4172 #16 AWGAMMSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 2WFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEELEVATOR LOBBYSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFOURTH FLOORCORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 3UP TOFIFTH FLOORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 3SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEELEVATOR LOBBYSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETOP OF ELEVATORSHAFTHFHEAT DETECTORATD-L3 W/ B300-6 BASETOP OF ELEVATORSHAFTAOMADDRESSABLE RELAYMODULEAOM-2RFELEVATOR FIREMEN'SHAT2 #16 AWGTO ELEVATORCONTROLLER(BY OTHERS)AOMADDRESSABLE RELAYMODULEAOM-2RFELEVATOR RECALL MAIN2 #16 AWGTO ELEVATORCONTROLLER(BY OTHERS)AOMADDRESSABLE RELAYMODULEAOM-2RFELEVATOR RECALLALTERNATE2 #16 AWGTO ELEVATORCONTROLLER(BY OTHERS)SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 2WFSPRINKLER FLOW SWITCH(BY OTHERS)ADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FSTAIR 22 #16 AWGAMMSPRINKLER TAMPER SWITCH(BY OTHERS)TSEOLEOLSPSMOKE DETECTORASD-PL3 W/ B300-6 BASELAUNDRY 513SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEELEC 517ADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 5172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 5172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 5172 #16 AWGAMMSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTORAGE 509SPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEFIFTH FLOOR CORRIDORSPSMOKE DETECTORASD-PL3 W/ B300-6 BASEELEVATOR LOBBYSPSMOKE DETECTORASD-PL3 W/ B300-6 BASETOP OF ELEVATORSHAFTHFHEAT DETECTORATD-L3 W/ B300-6 BASETOP OF ELEVATORSHAFTAOMADDRESSABLE RELAYMODULEAOM-2RFELEVATOR FIREMEN'SHAT2 #16 AWGTO ELEVATORCONTROLLER(BY OTHERS)AOMADDRESSABLE RELAYMODULEAOM-2RFELEVATOR RECALL MAIN2 #16 AWGTO ELEVATORCONTROLLER(BY OTHERS)AOMADDRESSABLE RELAYMODULEAOM-2RFELEVATOR RECALLALTERNATE2 #16 AWGTO ELEVATORCONTROLLER(BY OTHERS)SPSMOKE DETECTORASD-PL3 W/ B300-6 BASESTAIR 124VDC NAC CIRCUITSPSMOKE DETECTORASD-PL3 W/ B300-6 BASECORRIDORBPSTO HPF902ULADABOOSTER PANELTO HPF902ULADABOOSTER PANELBPSBPSAMSADDRESSABLESUPERVISED OUTPUTMODULEAOM-2SFTO TRIP NAC PANELSMDLSYNCH MODULEMDL36 #14 AWG2 #14 AWG2 #14 AWGTO HPF902ULADABOOSTER PANELBPSTO HPF902ULADABOOSTER PANELTO HPF902ULADABOOSTER PANELBPSBPSAMSADDRESSABLESUPERVISED OUTPUTMODULEAOM-2SFTO TRIP NAC PANELSMDLSYNCH MODULEMDL36 #14 AWG2 #14 AWG2 #14 AWGTO HPF902ULADABOOSTER PANELBPSTO HPF902ULADABOOSTER PANELTO HPF902ULADABOOSTER PANELBPSBPSAMSADDRESSABLESUPERVISED OUTPUTMODULEAOM-2SFTO TRIP NAC PANELSMDLSYNCH MODULEMDL36 #14 AWG2 #14 AWG2 #14 AWG2 #16 AWG2 #16 AWG2 #16 AWGTO HPF902ULADABOOSTER PANELBPSTO HPF902ULADABOOSTER PANELTO HPF902ULADABOOSTER PANELBPSBPSAMSADDRESSABLESUPERVISED OUTPUTMODULEAOM-2SFTO TRIP NAC PANELSMDLSYNCH MODULEMDL36 #14 AWG2 #14 AWG2 #14 AWG2 #16 AWGHORN/STROBEP2RLMECHANICAL 111A15STROBESRLSTORAGE 11015STROBESRLRESTROOM15STROBESRLRESTROOM15STROBESRLVESTIBULE 10715HORN/STROBEP2RLMECHANICAL 10615STROBESRLSUPPORTIVE SVCS 10515STROBESRLPROPERTY MNGR 10415STROBESRLCONFERENCE 10215HORN/STROBEP2RLCORRIDOR15STROBESRLLOBBY75STROBESRLVESTIBULE 10015EOLHORN/STROBEP2RLGALLERY75HORN/STROBEP2RLSTUDIO75HORN/STROBEP2RLGALLERY75STROBESRLGALLERY OFFICE15STROBESRLBREAKROOM15STROBESRLSTUDIO OUTER WALL?752 # 14 AWG24VDC NAC CIRCUIT2 # 14 AWG24VDC NAC CIRCUITHORN/STROBEP2RLOUTSIDE STAIR 275EOLHORN/STROBEP2RLEAST WALL75STROBESRLSOUTH WALL75HORN/STROBEP2RLSOUTHWEST BYCORRIDOR75STROBESRLCORRIDOR15STROBESRLRESTROOM 15315STROBESRLRESTROOM 15415HORN/STROBEP2RLCORRIDOR15STROBESRLFITNESS15HORN/STROBEP2RLCOMMUNITY ROOM75EOLFP1FP1FA17/25/20 NTSCES ALCSCHRAMMDEMCO ELECTRICITHACA ARTHAUSFIRE ALARM SYSTEMRISER WIRING DIAGRAM PART A NAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWG1 #12AWG3 #12AWGNO PENETRATIONS INBOTTOM OF CABINETHONEYWELL POWERHP902ULADALOCATED ELECTRICAL217DEDICATED 120VACPOWER FEEDEARTH GROUNDNAC CIRCUIT2 # 14 AWG1 #12AWG3 #12AWGNO PENETRATIONS INBOTTOM OF CABINETDEDICATED 120VACPOWER FEEDEARTH GROUNDADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 2172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 2172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 2172 #16 AWGAMMAMSADDRESSABLESUPERVISED OUTPUTMODULEAOM-2SFTO TRIP NAC PANELS2 #16 AWGMDLSYNCH MODULEMDL32 #16 AWGFROM PREVIOUSDEVICE ONSLC CIRCUIT(SEE FA1)TO NEXT DEVICE ONSLC CIRCUIT(SEE FA1)6 #14AWGHORN LOW FREQUENCYHWL-LFLIVING ROOMUNIT 211LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBESTROBESRLELEC 21715STROBESRLLAUNDRY 21315HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 208LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 206LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 206LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN/STROBEP2RLCORRIDOR15HORN LOW FREQUENCYHWL-LFLIVING ROOMUNIT 204LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 204LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 202LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 202LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 201LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 201LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 201LFSTROBESRLCORRIDOR15HORN LOW FREQUENCYHWL-LFLIVING ROOMUNIT 203LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 210LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 210LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 207LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 207LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 207LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 205LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 205LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 216LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 216LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 214LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 214LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 212LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 212LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSTROBESRLCORRIDOR15EOLNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWG1 #12AWG3 #12AWGNO PENETRATIONS INBOTTOM OF CABINETHONEYWELL POWERHP902ULADALOCATED ELECTRICAL217DEDICATED 120VACPOWER FEEDEARTH GROUNDNAC CIRCUIT2 # 14 AWGNAC PNL TRIP2 # 14 AWGNAC PNL TRIP2 # 14 AWGNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWGHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 218LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 218LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 218LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 219LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMEOLHORN/STROBEP2RLCORRIDOR15HORN LOWFREQUENCYHWL-LFBEDROOMUNIT 220LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 220LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSTROBESRLCORRIDOR15HORN/STROBELOW FREQUENCYP2WL-LFBEDROOMUNIT 221HORN/STROBELOW FREQUENCYP2WL-LFBEDROOMUNIT 221 STROBESWLBATHROOMSTROBESWLBATHROOMEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 220LFHORN/STROBELOW FREQUENCYP2WL-LFLIVING ROOMUNIT 221HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 224LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 224LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 224LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEEOLHORN/STROBEP2RLCORRIDOR15HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 225LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 225LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 226LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 226LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 227LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 227LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 227LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 227LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSTROBESRLCORRIDOR15HORN/STROBELOW FREQUENCYP2WL-LFLIVING ROOMUNIT 230STROBESWLBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 234LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 234LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN/STROBEP2RLCORRIDOR15STROBESRLCORRIDOR15HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 229LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 231LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 233LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBE1515LF185LF185LF185HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 232LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBE15LF185HORN/STROBELOW FREQUENCYP2WL-LFBEDROOMUNIT 235 STROBESWLBATHROOMHORN/STROBELOW FREQUENCYP2WL-LFLIVING ROOMUNIT 23515LF185LF185EOLEOLEOLNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWG1 #12AWG3 #12AWGNO PENETRATIONS INBOTTOM OF CABINETHONEYWELL POWERHP902ULADALOCATED ELECTRICAL317DEDICATED 120VACPOWER FEEDEARTH GROUNDNAC CIRCUIT2 # 14 AWG1 #12AWG3 #12AWGNO PENETRATIONS INBOTTOM OF CABINETDEDICATED 120VACPOWER FEEDEARTH GROUNDADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 3172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 3172 #16 AWGAMMADDRESSABLE INPUTMODULEAMM-2FTO MONITOR NAC PANELELEC 3172 #16 AWGAMMAMSADDRESSABLESUPERVISED OUTPUTMODULEAOM-2SFTO TRIP NAC PANELS2 #16 AWGMDLSYNCH MODULEMDL32 #16 AWGFROM PREVIOUSDEVICE ONSLC CIRCUIT(SEE FA1)TO NEXT DEVICE ONSLC CIRCUIT(SEE FA1)6 #14AWGHORN LOW FREQUENCYHWL-LFLIVING ROOMUNIT 311LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBESTROBESRLELEC 31715STROBESRLLAUNDRY 31315HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 308LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 306LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 306LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN/STROBEP2RLCORRIDOR15HORN LOW FREQUENCYHWL-LFLIVING ROOMUNIT 304LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 304LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 302LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 302LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 301LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 301LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 301LFSTROBESRLCORRIDOR15HORN LOW FREQUENCYHWL-LFLIVING ROOMUNIT 303LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 310LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 310LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 307LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 307LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 307LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 305LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 305LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 316LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 316LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 314LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 314LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 312LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 312LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSTROBESRLCORRIDOR15EOLNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWG1 #12AWG3 #12AWGNO PENETRATIONS INBOTTOM OF CABINETHONEYWELL POWERHP902ULADALOCATED ELECTRICAL317DEDICATED 120VACPOWER FEEDEARTH GROUNDNAC CIRCUIT2 # 14 AWGNAC PNL TRIP2 # 14 AWGNAC PNL TRIP2 # 14 AWGNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWGNAC CIRCUIT2 # 14 AWGHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 318LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 318LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 318LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 319LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMEOLHORN/STROBEP2RLCORRIDOR15HORN LOWFREQUENCYHWL-LFBEDROOMUNIT 220LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 220LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSTROBESRLCORRIDOR15HORN LOWFREQUENCYHWL-LFBEDROOMUNIT 321HORN LOWFREQUENCYHWL-LFBEDROOMUNIT 321SINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 220LFHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 321HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 324LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 324LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 324LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEEOLHORN/STROBEP2RLCORRIDOR15HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 325LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 325LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 326LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 326LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 327LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 327LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMEOLHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 327LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 327LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMSTROBESRLCORRIDOR15HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 330HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 334LFHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 334LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN/STROBEP2RLCORRIDOR15STROBESRLCORRIDOR15HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 329LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 331LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 333LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBE1515HORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 232LFSINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEHORN LOWFREQUENCYHWL-LFBEDROOMUNIT 335 SINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEBATHROOMHORN LOWFREQUENCYHWL-LFLIVING ROOMUNIT 335EOLEOLEOLHONEYWELL POWERHP902ULADALOCATED ELECTRICAL217HONEYWELL POWERHP902ULADALOCATED ELECTRICAL317LFLFLFLFLFLFGENERAL NOTES;1. BACK BOXES ARE DIFFERENT FOR LIVING ROOM AND BEDROOM LOWFREQUENCY DEVICES THAN REST OF SYSTEM A/V'S AND VISUAL ONLYDEVICES.2. FOR LIVING ROOM AND BEDROOM LOW FREQUENCY DEVICES INSTALL4 INCH SQUARE BACK BOX, NO MUD RING.3. FOR ALL OTHER WALL MOUNT A/V AND VISUAL ONLY DEVICES USESINGLE GANG BACK BOX4. CEILING MOUNTED A/V'S IN THE GARAGE MOUNT TO 4 INCH SQUAREBACK BOX.5. CEILING MOUNT CO STROBES MOUNT TO 4 INCH SQUARE ELECTRICALBACK BOX, NO MUD RING.6. WEATHERPROOF A/V'S COME WITH BACK BOX.FOURTH AND FIFTH FLOOR ARE IDENTICAL TO THIRD FLOOR.SINGLE GANGBACK BOX WITHCOVER PLATERFOR FUTURESTROBEFP1FP1FA27/25/20 NTSCES ALCSCHRAMMDEMCO ELECTRICITHACA ARTHAUSFIRE ALARM SYSTEMRISER WIRING DIAGRAM PART B 213NOTE: TO ENSURE PROPER CIRCUITSUPERVISION DO NOT LOOP WIREUNDER TERMINAL.THISNOTTHISSLC INITIATING CIRCUIT FROMFACP OR CLOSEST EXISTINGINITIATING DEVICESLC INITIATING CIRCUIT TO NEXT DEVICE ORRETURN TO ORIGINATING DEVICE TO MAINTAINCIRCUIT SUPERVISIONPOS (+)NEG (-)POS (+)NEG (-)M/N B300-6 BASE WITH ASD-PL3 SMOKE OR ATD-L3HEAT DETECTOR HEAD4312+-ADDRESSABLE SWITCHES LOCATEDINSIDE COVER OF UNITPRODUCT IDENTIFICATION LABELLOOPADDRESSMNOTE: TO ENSURE PROPER CIRCUITSUPERVISION DO NOT LOOP WIREUNDER TERMINAL.THISNOTTHISSLC INITIATING CIRCUIT FROMFACP OR CLOSEST EXISTINGINITIATING DEVICESLC INITIATING CIRCUIT TO NEXT DEVICE ORRETURN TO ORIGINATING DEVICE TO MAINTAINCIRCUIT SUPERVISIONPOS (+)NEG (-)POS (+)NEG (-)STROBE CANDELA OUTPUT SETTINGS/CURRENT DRAW15 CD 30 CD75 CD95 CD110 CDWALL MOUNTEDHORN/STROBE APPLIANCEGFCI M/N P2RLDEVICE TYPEMODEL NUMBERMOUNTINGREQUIREMENTS2" x 4" x 1 7/8"STANDARD BACK BOXSURFACE BACK BOXM/N SBBCRLGFCI M/N SRLWALL MOUNTEDSTROBE APPLIANCECEILING MOUNTEDHORN/STROBE APPLIANCECEILING MOUNTEDSTROBE APPLIANCEGFCI M/N PC2RLGFCI M/N SCRL2" x 4" x 1 7/8"STANDARD BACK BOXSURFACE BACK BOXM/N SBBCRL0.054 AMPS0.071 AMPS0.043 AMPS0.041 AMPS0.074 AMPS 0.121 AMPS 0.142 AMPS 0.162 AMPS0.090 AMPS 0.143 AMPS 0.165 AMPS 0.187 AMPS0.063 AMPS0.063 AMPS 0.111 AMPS0.107 AMPS 0.121 AMPS0.134 AMPS 0.158 AMPS0.148 AMPS115 CD0.054 AMPS 0.071 AMPS 0.137 AMPS 0.161 AMPS 0.185 AMPSTEMP LOWTEMP HIGHTEMP LOWTEMP HIGH0.044 AMPS 0.065 AMPS 0.111 AMPS 0.133 AMPS 0.157 AMPS-+24VDC NAC STROBE POWER CIRCUITFROM FACP, BOOSTER PANEL ORCLOSEST STROBE DEVICECANDELA SELECT75- + +-+24VDC NAC STROBE POWER CIRCUIT TONEXT STROBE OR EOL AT LAST DEVICEMOUNTING PLATECANDELA SELECT75NOTE: E.C. TO ENSURE AUDIO SELECT DIAL IS SETAT "2" AND CANDELA SELECTION DIAL IS SETACCORDING TO VALUES SHOWN ON RISERDRAWING PRIOR TO INSTALLATION:STROBEM/N SRLHORN/STROBEM/N P2RL- + +- + +12345678AUDIO SELECT4 CONT LOW3 CONT HIGH2 TEMP 3 LOW1 TEMP 3 HIGH5 TEMP 3 3K HIGH6 TEMP 3 3K LOW7 CONT 3K HIGH8 CONT 3K LOWGENERAL NOTES;1. SHIELDED CABLE SHALL NOT BE USED ON ANY CIRCUITS AS ITRELATES TO THIS FIRE DETECTION SYSTEM UNLESS OTHERWISE NOTED.2. ALL FIRE ALARM CABLING MUST BE INSTALLED A MINIMUM OF1' FROM ALL OTHER HIGH VOLTAGE, LOW VOLTAGE, & TELECOM CABLINGAND A MINIMUM OF 3' FROM ANY BUILDING LIGHTING BALLASTS.3. A TYPICAL SLC INITIATING CIRCUIT MAY HAVE UP TO 159 SENSORSTYLE DEVICES (SMOKE/HEATS/DUCT DETECTORS) AND 159MODULE STYLE DEVICES (PULL STATIONS, MODULES,CONTROL & INPUT MODULES).4. POLARITY MUST BE OBSERVED ON ALL CIRCUITS.5. E.C. TO ENSURE AUDIO SELECT DIAL IS SET AT "2" ANDCANDELA SELECTION DIAL IS SET ACCORDING TO VALUESSHOWN ON RISER DRAWING PRIOR TO INSTALLATION- + +24VDC NAC POWER CIRCUIT FROM FACP,BOOSTER PANEL OR CLOSEST NAC DEVICE-+EOL RESISTOR AT LAST DEVICEWALL MOUNTED LOWFREQUENCYSOUNDER/STROBEGFCI M/N P2WL-LF4" x 4" x 1 1/2"STANDARD BACK BOX0.115 AMPS 0.158 AMPS 0.173 AMPS 0.182AMPS 0.212 AMPSWALL MOUNTED LOWFREQUENCY SOUNDERGFCI M/N HWL-LFLOW FREQUENCY SOUNDER ONLY APPLIANCES DRAWS 0.108 AMPS EACH.4" x 4" x 1 1/2"STANDARD BACK BOXWEATHERPROOFBACK BOXM/N SA-WBBWWEATHERPROOFHORN/STROBE APPLIANCEGFCI M/N P2RK0.079 AMPS 0.107 AMPS 0.176 AMPS 0.194 AMPS0.066 AMPS 0.093 AMPS 0.154AMPS 0.179 AMPSTEMP LOWTEMP HIGH0.212 AMPS0.198 AMPS30 CD 75 CD 95 CD 110 CD 135 CD 185 CD0.266 AMPSUNSWITCHED LIGHTING CIRCUITNLWIRE NUTREDSMOKE ALARM STROBE LIGHTHEAT ALARMCO/SMOKE ALARMBLACKWHITEREDBLACKWHITEREDBLACKWHITEREDBLACKWHITESCALE: NTSTYPICAL 120 VAC APARTMENT DEVICE WIRING1SCALE: NTSTYPICAL SMOKE OR HEAT BASE WIRING2SCALE: NTSTYPICAL MANUAL PULL STATION WIRING DETAILS5SCALE: NTSTYPICAL NAC APPLIANCE WIRING DETAILS6AOM-2RF ADDRESSABLE RELAY MODULEFORM "C" RELAY RATED AT2 A @ 30 VDC,.5 A @ 120 VAC024110 22024VDC POWER FROM FIRECONTROL PANEL OR BOOSTER(+)(-)COM N/ON/C120VAC FAN POWEROR SAFETY CIRCUIT120VAC POWER FEED(+)(-)(-)(+)MR101/CNOTE:ACTUAL ENERGIZED STATE =N/O COM N/CTHE MR-101/C WILL BEPOWERED ALL THE TIMETHE RELAY CONTACTS ARELABELED IN THEIRNON-ENERGIZED STATE.THIS BEING THE CASE, THEACTUAL CONTACTS WILLFUNCTION OPPOSITE OFTHEIR LABELED STATE.THEREFORE WIRE RELAYOUTPUT ACCORDINGLYLOCATE RELAY ARRAY WITHIN3' OF CONTROLLED DEVICESLC INITIATING CIRCUIT FROM FACP ORCLOSEST EXISTING INITIATING DEVICENEG-POS+SLC INITIATING CIRCUIT TO NEXT DEVICE OR RETURNTO ORIGINATING DEVICE TO MAINTAIN CIRCUITSUPERVISIONNEG-POS++ (POS)- (NEG)POS (+)NEG (-)SLC INITIATING CIRCUIT TO NEXT DEVICEOR RETURN TO ORIGINATING DEVICE TOMAINTAIN CIRCUIT SUPERVISION2 #16AWGSLC INITIATING CIRCUIT FROMCLOSEST EXISTINGINITIATING DEVICEAMM-2FMONITOR MODULEYELLOWPURPLE(-)(+)BLACKREDMONITOREDDEVICEEOL FROMAMM-2FSCALE: NTSTYPICAL AOM-2RF WITH MR1013SCALE: NTSTYPICAL INPUT MODULE WIRING DETAILS4FP1FP1FA37/25/20 NTSCES ALCSCHRAMMDEMCO ELECTRICITHACA ARTHAUSFIRE ALARM SYSTEMTYPICAL DEVICE WIRING DETAILS