Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Demco 26 05 00 Common Electric materials_REVIEWED AND APPROVED
Vecino Construction, LLC 305 W Commercial Springfield, Missouri 65803 Phone: (417) 720-1577 Project: 18-260 - Ithaca Arthaus 130 Cherry St Ithaca, New York 14850 Phone: 417-720-1577 1.1.A - Product Data REVISION: 0 SUBMITTAL MANAGER:Corey Olmstead (Vecino Construction LLC) STATUS: Open DATE CREATED: 02/3/2020 ISSUE DATE: SPEC SECTION: 26 05 00 - Common Work Results for Electrical RESPONSIBLE CONTRACTOR: Demco New York Corp RECEIVED FROM:John Orr RECEIVED DATE: SUBMIT BY: 05/15/2020 FINAL DUE DATE:05/28/2020 LOCATION: COST CODE: TYPE: Product Information APPROVERS:Corey Olmstead (Vecino Construction LLC), Yossi Bronsnick (Taitem Engineering), Layne Hunton (Vecino Design, LLC), Anna Legard (Taitem Engineering) BALL IN COURT: John Orr (Demco New York Corp) DISTRIBUTION: Matt Kingsley (Vecino Construction LLC) , Marty Bevis (Vecino Construction LLC) , Corey Olmstead (Vecino Construction LLC) DESCRIPTION: Fire penetration products, sleeves, sleeve seals, wireways, raceways, conduit, conductors, supports, and electrical identification. SUBMITTAL WORKFLOW NAME SENT DATE DUE DATE RETURNED DATE RESPONSE ATTACHMENTS COMMENTS John Orr 05/14/2020 Pending Corey Olmstead 05/21/2020 Pending Yossi Bronsnick 05/28/2020 Pending Layne Hunton 05/28/2020 Pending Anna Legard 05/28/2020 Pending BY DATE COPIES TO Vecino Construction, LLC Page 1 of 1 Printed On: 06/11/2020 12:31 PM Submittal #26 05 00-1.0 26 05 00 - Common Work Results for Electrical 6/11/20 AEL 6/16/20 1-866-663-9267 4 Aluminum Armored MC Cable UL Type MC, 600 V, 90°C dry rated - Lead Free Copper Conductors ENERGEX® MC 120 Applications ENERGEX® MC 120 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction in accordance with NEC 2008 and NEC 2011 Article 330. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC 2008 and NEC 2011 Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC 2008 and NEC 2011 Article 300.22(C) ONLY. Nexans MC 120 cable is Lead Free and RoHS compliant. Construction Conductor: Solid bare annealed copper conforming to ASTM B3. Stranded bare annealed copper conforming to ASTM B3 and ASTM B787 for sizes 14 to 8 AWG and ASTM B8 for sizes 6 AWG and larger. Insulation: Colored PVC/Nylon Type THHN in accordance with UL 83, flame retardant, meeting UL VW-1 flame test for sizes 14 to 1 AWG. Colored cross- linked polyethylene Type XHHW-2 per UL 44 for sizes 1/0 AWG and larger. Ground Wire: Green PVC/Nylon Type THHN insulation for phase conductor sizes from 14 to 1 AWG, sized in accordance with NEC 2008 and NEC 2011, and UL, (green cross- linked polyethylene Type XHHW-2 for phase conductors sized 1/0 and larger). Assembly: Conductors are cabled with grounding wire. A marker tape/ core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS TYPE MC 600 VOLT FOR CT USE (SIZE) THHN (UL) E-47409 LEAD FREE (MFG DATE). Specifications UÊiiÌÃÊ1Ê{{\Ê/ iÀÃiÌÃÕ>Ìi`Ê Wires and Cables (1/0 AWG and larger) UÊiiÌÃÊ1ÊnÎ\Ê/ iÀ«>ÃÌVÃÕ>Ìi`Ê Wires and Cables (14 to 1 AWG) UÊ/iÃÌi`ÊÌÊ1Ê£{Ç\ÊÀiÊ/iÃÌÃÊvÊ Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) UÊiiÌÃÊ1Ê£xÈ\ÊiÌ>Ê >`Ê >LiÃÊ UÊiiÌÃÊ1Ê£xn£\Ê,iviÀiViÊ-Ì>`>À`Ê for Electrical Wires, Cables, and Flexible Cords UÊiiÌÃÊ1ÊÓxxÈ\Ê7ÀiÊ>`Ê >LiÊ Test Methods UÊiÃ}>Ìi`Ê/Þ«iÊ Ê«iÀÊ ÊÓäänÊ and NEC 2011 Article 330 Product features UÊ >LiÃÊ>ÀiÊ1ÊÃÌi`Ê>ÃÊ/Þ«iÊ ]Ê 600 V UÊÊÊ1ÊÃÌi`ÊÃÕ>Ìi`ÊV`ÕVÌÀà UÊÀiÊ7>Ê*iiÌÀ>ÌÊÀ>Ìi`Ê depending on type of installation and fire-stop system used UÊ1ÊÃÌi`ÊvÀÊÕÃiÊÊV>LiÊÌÀ>ÞÃÊ«iÀÊ NEC 2008 Article 330.10(A)(6) or NEC 2011 Article 330.10(6) UÊ1ÊÃÌi`ÊvÀÊÕÃiÊÊ >ÃÃÊ]ÊÛ°ÊÓÊ«iÀÊ NEC 2008 and NEC 2011 Article 501.10(B)(1), Class II, Div.2 per NEC 2008 and NEC 2011 Article 502.10(B)(1) and Class III, Div. 1 & 2 per NEC 2008 and NEC 2011 Article 503.10(A) and with approved termination fittings. UÊ/i«iÀ>ÌÕÀiÊÀ>Ì}ÊvÊäc Ê`ÀÞÊ UÊ ÝViiÌÊiV >V>ÊEÊ« ÞÃV>Ê properties UÊ} ÌÜi} ÌÊ>ÕÕÊ>ÀÀ UÊ-Ì>`>À`Ê iÝ>ÃÊ , 8ÁÊ Ê 120 from 14 AWG to 1 AWG is Lead Free and RoHS compliant Options The following constructions can be provided on special orders: UÊ-«iV>ÊV`ÕVÌÀÊVÕÌà UÊ87ÓÊÃÕ>ÌÊ,-Ê compliant) on sizes 14 to 1 AWG UÊ `ÕVÌÀÊÃâiÃÊ>À}iÀÊÌ >Ê£ÉäÊ AWG 1-866-663-9267 5 Bend Radius: 7 × overall diameter Notes: UÊiÃÃÊ>`ÊÜi} ÌÃÊà ÜÊ>ÀiÊ>ÊÛ>ÕiÃ]ÊÃÕLiVÌÊÌÊÃÌ>`>À`Ê`ÕÃÌÀÞÊÌiÀ>Við UÊÊ«>VÌiÃÊ>ÀiÊÊ>VVÀ`>ViÊÜÌ Ê ÊÓäänÊ/>LiÊΣ䰣ÈÊÀÊ ÊÓ䣣Ê/>LiÊΣ䰣x ®£È®ÊvÀÊV`ÕVÌÀÃÊÊ>ÊÀ>ViÜ>ÞÊ>ÌÊÎäc Ê>LiÌÊÌi«iÀ>ÌÕÀið Èäc ÊÊ7 iÊÌiÀ>Ìi`ÊÌÊiµÕ«iÌÊvÀÊVÀVÕÌÃÊÀ>Ìi`Ê£ääÊ>«iÀiÃÊÀÊiÃÃÊÀÊ>Ài`ÊvÀÊV`ÕVÌÀÊÃâiÃÊ£{ÊÌ ÀÕ} Ê£Ê7° Çxc ÊÊ7 iÊÌiÀ>Ìi`ÊÌÊiµÕ«iÌÊvÀÊVÀVÕÌÃÊÀ>Ìi`ÊÛiÀÊ£ääÊ>«iÀiÃÊÀÊ>Ài`ÊvÀÊV`ÕVÌÀÃÊ>À}iÀÊÌ >ÊÃâiÊ£Ê7° äc ÊÊ7iÌÊÀÊ`ÀÞÊV>ÌðÊÀÊ>«>VÌÞÊ`iÀ>Ì}Ê«ÕÀ«Ãið UÊÊÀÊVÀÀiVÌÊv>VÌÀÃÊvÀÊ`vviÀiÌÊ>LiÌÊÌi«iÀ>ÌÕÀiÃÊ>`Ê>«>VÌiÃÊ>ÌÊ`vviÀiÌÊV`ÕVÌÀÊÌi«iÀ>ÌÕÀiÊÀ>Ì}ÃÊÃiiÊ ÊÓäänÊ/>LiÊΣ䰣ÈÊÀÊ ÊÓä££Ê Table 310.15(B)(16). UÊÊ ÊÓäänÊ>`Ê ÊÓ䣣ÊÀÌViÊÓ{ä°{®ÊÀiµÕÀiÃÊÌ >ÌÊÛiÀVÕÀÀiÌÊ«ÀÌiVÌÊÌÊiÝVii`Ê£xÊ>«iÀiÃÊvÀÊ£{Ê7]ÊÓäÊ>«iÀiÃÊvÀÊ£ÓÊ7]Ê>`ÊÎäÊ amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 Article 240.4(E) through (G). (1) Where the 4th (white) conductor is the neutral of a balanced 3 phase system. ENERGEX® MC 120 Aluminum Armored MC Cable UL Type MC, 600 V, 90°C dry rated - Lead Free Copper Conductors UL 44 UL 83 UL 1569 *>ÀÌ ÕLiÀ Number of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal Diameter over Armor Approximate Net Cable Weight Ampacity amps inches mm lb/kft kg/km 60°C 75°C 90°C 250 ft coil 1000 ft reel 618777 642876 2 14 (1) 14 (1)Ü ÌiÉL>V0.446 11.33 87 129 15 15 15 618785 642884 3 14 (1) 14 (1)Ü ÌiÉL>VÉÀi`0.473 12.01 106 158 15 15 15 670050 670051 4 14 (1) 14 (1)Ü ÌiÉL>VÉÀi`ÉLÕi 0.505 12.83 123 183 15 (1)15(1)15(1) 618793 635045 2 12 (1) 12 (1)Ü ÌiÉL>V0.483 12.27 118 176 20 20 20 618801 635052 3 12 (1) 12 (1)Ü ÌiÉL>VÉÀi`0.514 13.06 145 216 20 20 20 618819 635060 4 12 (1) 12 (1)Ü ÌiÉL>VÉÀi`ÉLÕi 0.550 13.97 173 257 20 (1)20(1)20(1) 618827 636977 2 10 (1) 10 (1)Ü ÌiÉL>V0.550 13.97 164 244 30 30 30 618835 636985 3 10 (1) 10 (1)Ü ÌiÉL>VÉÀi`0.588 14.94 207 308 30 30 30 618843 640177 4 10 (1) 10 (1)Ü ÌiÉL>VÉÀi`ÉLÕi 0.643 16.33 244 363 30 (1)30(1)30(1) 642892 642900 2 12 (19) 12 (19)Ü ÌiÉL>V0.483 12.27 118 176 20 20 20 644997 645002 3 12 (19) 12 (19)Ü ÌiÉL>VÉÀi`0.514 13.06 145 216 20 20 20 645010 645028 4 12 (19) 12 (19)Ü ÌiÉL>VÉÀi`ÉLÕi 0.550 13.97 173 257 20 (1)20(1)20(1) 672972 672980 2 10 (19) 10 (19)Ü ÌiÉL>V0.550 13.97 164 244 30 30 30 672576 672584 3 10 (19) 10 (19)Ü ÌiÉL>VÉÀi`0.588 14.94 207 308 30 30 30 670017 672634 4 10 (19) 10 (19)Ü ÌiÉL>VÉÀi`ÉLÕi 0.643 16.33 244 363 30 (1)30(1)30(1) 200 ft reel 500 ft reel 670085 670190 2 8 (19) 10 (19)Ü ÌiÉL>V0.656 16.66 229 341 40 50 55 670086 642918 3 8 (19) 10 (19)Ü ÌiÉL>VÉÀi`0.713 18.11 300 446 40 50 55 ———670208 4 8 (19) 10 (19)Ü ÌiÉL>VÉÀi`ÉLÕi 0.777 19.74 371 552 40 (1)50(1)55(1) 125 ft reel 500 ft reel 670088 670182 2 6 (19) 8 (19)Ü ÌiÉL>V0.742 18.85 330 491 55 65 75 670089 643445 3 6 (19) 8 (19)Ü ÌiÉL>VÉÀi`0.811 20.60 435 647 55 65 75 ——— 670174 4 6 (19) 8 (19)Ü ÌiÉL>VÉÀi`ÉLÕi 0.886 22.50 541 805 55 (1)65(1)75(1) ——— 670539 3 4 (19) 8 (19)Ü ÌiÉL>VÉÀi`0.941 23.90 624 929 70 85 95 ——— ——— 4 4 (19) 8 (19)Ü ÌiÉL>VÉÀi`ÉLÕi 1.056 26.82 855 1272 70 (1)85(1)95(1) ——— 673848 3 3 (19) 6 (19)Ü ÌiÉL>VÉÀi`1.016 25.81 795 1183 85 100 115 ——— 670237 4 3 (19) 6 (19)Ü ÌiÉL>VÉÀi`ÉLÕi 1.129 28.68 1049 1561 85 (1)100(1)115(1) ——— 670521 3 2 (19) 6 (19)Ü ÌiÉL>VÉÀi`1.091 27.71 966 1438 95 115 130 ——— 673871 4 2 (19) 6 (19)Ü ÌiÉL>VÉÀi`ÉLÕi 1.201 30.51 1245 1853 95 (1)115(1)130(1) ——— ——— 3 1 (19) 6 (19)Ü ÌiÉL>VÉÀi`1.203 30.56 1427 2124 110 130 145 ——— ——— 3 1/0 (19) 6 (19)Ü ÌiÉL>VÉÀi`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art No.&21),'(17,$/ THIS MATERIAL IS OWNED BY THE ALLIED MOULDED PRODUCTS COMPANY, IS DISCLOSED IN CONFIDENCE,AND IS NOT TO BE REPRODUCED OR DISTRIBUTEDWITHOUT PRIOR WRITTEN PERMISSION FROMALLIED MOULDED PRODUCTS. 12/16/2014 1099-Z4 SINGLE GANG 22.5 CU.IN. ISSUE DATE: !" #$ % &'( %&%)( ( %&*) + %* ,-./ !(0 %1 ! "# 0%%1 % 0+ "$#$%1 % 0 %23 4-"" !5- 3 ! &'(")'$ 6 6 -6 "6 6 "!" !5 - " 3 - - 37879 3! // (##*(% ,--/ 3:;6- $(()$ ,)2< (9=> ,% 1( &)'*($$&(% & + , ,)2<+%=> ,9??;1%*1@9"A)> ,B ,=3 !=,)2< (9 &)+ + ( -. !!A C % ,=>3 2<6A D 9??1%*1@ !5" B %*%) #") ,(')(* >!" A#9 ,%" 37'7 "!/- )7 (%(*,(')(*$ E 6C !/ ! A6A 3 !" #$ %% &'( %&%)* +& ) , % *, '-./ % ! , ! "# 0+%%1 * 0 "$#$%1 % 0 %23 4 "" !5- 3 ! &'(")'$ 6 "" 3/ 6 "!" !5 - " 3 - -37(7 8 39 (##*(% '--/ :; 6- $(()$ ')2<+ *8=> '% +1* &)'*($$&(% & + , ')2<,%=> '8??;1%1@8"9)> 'A '=3 !=')2<+ *8 &)+ + ( -. !!9 B % '=>3 2<69 C 8??1%1@ !5" A %*%) #") ,(')(* >!" 9#8 ,%" " 3 (%(*,(')(*$ 8! 969 3 &2175$&7(' >@(;7(1'(' 7+5($'6 127(6%2;0$7(5,$/),%(5*/$665(,1)25&('32/<(67(563(('./$030$7(5,$/39&%$50$7(5,$/*$/9$1,=('67((/02817,1*%5$&.(70$7(5,$/*$/9$1,=('67((/02817,1*%5$&.(76&5(:0$7(5,$/=,1&3/$7('67((/8//,67(':,7++285),5(5$7,1*)25:$//$1'&(,/,1*$'-8670(17%$5+$1*(563(('./$036)$&725<,167$//(' R $//,('028/'('352'8&76%5<$12+,2 7KH2ULJLQDO)LEHU*ODVV2XWOHW%R[ PRODUCT SERIES Part No.&21),'(17,$/ THIS MATERIAL IS OWNED BY THE ALLIED MOULDED PRODUCTS COMPANY, IS DISCLOSED IN CONFIDENCE,AND IS NOT TO BE REPRODUCED OR DISTRIBUTEDWITHOUT PRIOR WRITTEN PERMISSION FROMALLIED MOULDED PRODUCTS. 06/01/2015 9364-BHK 4" ROUND 15.0 CU. IN. ISSUE DATE: !"#$% #& '&'() &*( + '&,( + ' -./0 !)1 ) 2 "# 1*'',,)* "$#$', ' 1 # 3-1**''1 %34 5 5562 27. 4 2 &'(")'$ & 8 62 . 2 05 79& 8 525540 (##*(% -. .0 :" 8. 5 $(()$ -(3!* );<= -' *,) &)'*($$&(% & + , -(3!+'<= -;>>",',?;59(= -@ &)+ + ( -. 229 A ) &)+ + & . ( -. * 2.2742)&B4 !" # $%&&'()*( +, -" ". "/ %*%) #5( ,(')(* 989 ; ,%" .. 62 2 (C '(1C (%(*,(')(*$ ;2 9262 45 !"#$% #& '&'() ) '&*( + ) ,-./ !) * 0 "# 12''**)2 "$#$'* ' 1 # 3,122''1 3,+'+21' # %34 5-6670 08- 4 0 &'(")'$ & 9 70 - 0 / 9 -9 69 6 8:& 9 60 664/ (##*(% ,- -/ ;" 9- 6 $(()$ ,(3!2 )<=> ,' 2*) &)'*($$&(% & + , ,(3!+'=> ,<??"*'*@<6:(> ,A &)+ + ( -. 00: B ) !" # $%&&'()*( +, -" ". "/ %*%) #6( ,(')(* :0 ,%" -- 70 0 (C '(1C (%(*,(')(*$ <0 Outlet Boxes T&B Catalog Number: 52171 3/4 UPC Number:78599116710 Status:Active Description: 4 inch pre-galvanized steel square box, 2-1/8 inch deep, 30.3 cuin. Weld- ed construction with 3/4 inch knockouts. For use with conduit. Application For use with conduit General Cable Entry_IDW Knockouts Material Steel Finish Pre-Galvanized Volume (cu.in.)30.3 Construction Welded Knockouts-Each Side (Conduit)(2) - 3/4 Knockouts-Each End (Conduit)(2) - 3/4 Knockouts-Bottom (Conduit)(3) - 1/2, (2) - 3/4 Knockouts_IDW Yes Dimension Information Size (inches)4 Depth (inches)2 1/8 Packaging Package in Units 50 T&B Sold in UOM Each T&B Weight Per UOM 86.3 lbs. per 100 Application Support Product Overview Available on Website NEC Article 314 - Boxes and Fittings Available on Website Product Brochure-4 Inch Square Old Work Box with Swing Ears Available on Website Product Brochure-MS Bracket Boxes Available on Website Product Brochure-Pre-Assemblies & Pre- Fab Components Available on Website Pre-Assemblies Labor Saving Calculator Available on Website Certifications RoHS Compliance No Certifications File Nbr: E 2969 For further technical assistance, please contact us... Thomas & Betts - USA 8155 T&B Blvd. T&B Technical Support MS 3B-50 Hours: 7AM - 6PM CDT Monday-Friday Outlet Box Covers T&B Catalog Number: 52 C 13 UPC Number:78599113875 Status:Active Description: 4 inch Pre-galvanized steel square box device cover, 1/2 inch raised, 3 cuin. For use with one device. ABB Attributes Shape Square Header Type_IDW Outlet Box Covers General Shape Square Material Steel Finish Pre-Galvanized Volume (cu.in.)3 Dimension Information Size (inches)4 Raised (inches)1/2 Number of Devices One Packaging Package in Units 50 T&B Sold in UOM Each T&B Weight Per UOM 22.8 lbs. per 100 Application Support Product Overview Available on Website NEC Article 314 - Boxes and Fittings Available on Website Pre-Assemblies Labor Saving Calculator Available on Website Certifications RoHS Compliance No Certifications File Nbr: E 2969 For further technical assistance, please contact us... Thomas & Betts - USA 8155 T&B Blvd. Memphis, TN 38125 www.tnb.com T&B Technical Support MS 3B-50 8155 T&B Blvd. Memphis, TN 38125 Hours: 7AM - 6PM CDT Monday-Friday Phone: (888) 862-3289 Fax: (901) 252-1321 Email:techsupport@tnb.com Outlet Box Covers T&B Catalog Number: 52C3-25 UPC Number:78599113800 Status:Active Description: 4 inch Pre-galvanized steel square box cover, 5/8 inch raised, 4.3 cuin. Center blanked with tapped ears on 2-3/4 inch centers. ABB Attributes Shape Square Header Type_IDW Outlet Box Covers General Shape Square Material Steel Finish Pre-Galvanized Volume (cu.in.)4.3 Dimension Information Size (inches)4 Raised (inches)5/8 Packaging Package in Units 25 T&B Sold in UOM Each T&B Weight Per UOM 24 lbs. per 100 Application Support Product Overview Available on Website NEC Article 314 - Boxes and Fittings Available on Website Pre-Assemblies Labor Saving Calculator Available on Website Certifications RoHS Compliance No Certifications File Nbr: E 2969 For further technical assistance, please contact us... Thomas & Betts - USA 8155 T&B Blvd. Memphis, TN 38125 www.tnb.com T&B Technical Support MS 3B-50 8155 T&B Blvd. Memphis, TN 38125 Hours: 7AM - 6PM CDT Monday-Friday Phone: (888) 862-3289 Fax: (901) 252-1321 Email:techsupport@tnb.com Ceiling Boxes T&B Catalog Number: 54171 1/2 3/4 UPC Number:78599117255 Status:Active Description: 4 inch Pre-galvanized steel octagon box, 2 1/8 inch deep, 22.5 cuin. Drawn construction with 1/2 inch & 3/4 inch knockouts. For use with con- duit. General Material Steel Finish Galvanized Volume (cu.in.)22.5 Construction Drawn Knockouts-Each Side (Conduit)(1) - 3/4" Knockouts-Each End (Conduit)(1) - 3/4" Knockouts-Bottom (Conduit)(3) - 1/2", (2) - 3/4" Dimension Information Diameter (inches)4 Depth (inches)2 1/8 Packaging T&B Order Multiple 25 Package in Units 25 T&B Sold in UOM Each T&B Weight Per UOM 61.4 lbs. per 100 Application Support T&B Sales Drawings wsd-000055 Product Overview Available on Website NEC Article 314 - Boxes and Fittings Available on Website Certifications RoHS Compliance No Certifications File Nbr: E 2969 For further technical assistance, please contact us... Thomas & Betts - USA 8155 T&B Blvd. Memphis, TN 38125 www.tnb.com T&B Technical Support MS 3B-50 8155 T&B Blvd. Memphis, TN 38125 Hours: 7AM - 6PM CDT Monday-Friday Phone: (888) 862-3289 Fax: (901) 252-1321 Email:techsupport@tnb.com TSGB16 & TSGB24 Field assembled TSGB16ASY & TSGB24ASY Pre-assembled Separate Assemble Adjust to box Bracket ready to attach to wall studs.Use screw gun to assemble to stud.Only one mounting screw required at each end of bracket. Attach electrical boxes. *KEYHOLES ARE ON TSGB16 ONLY WARNING:ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction 1.sheets are available at www.erico.com and from your ERICO customer service representative. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that 2.exceeds specified load ratings.All instructions must be completely followed to ensure proper and safe installation and performance. 3.Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause 4.product malfunction, property damage, serious bodily injury and death. Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment. 5.All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are 6.NEVER to be used for any other purpose. NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted. The customer is responsible for:a. Conformance to all governing codes.b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer.c. Using appropriate industry standard hardware as noted above. SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. PART NO DESCRIPTION STUD SPACING BOX DEPTH TSGB 16*ADJUSTABLE 11" TO 18"1-1/2" OR 2-1/8" TSGB16ASY*ADJUSTABLEPRE-ASSEMBLED 11" TO 18"1-1/2" OR 2-1/8" TSGB24*ADJUSTABLE 17" TO 26"1-1/2" OR 2-1/8" TSGB24ASY*ADJUSTABLEPRE-ASSEMBLED 17" TO 26"1-1/2" OR 2-1/8" TECHNICAL SUPPORT:www.erico.com CFS300_D INSTRUCTION SHEET 1 OF 2 © 2009 ERICO International Corporation TSGB 16* EZ20CH CEILING BOXDrawn By: D.S. Frank1-30-20092.3"2.23"3.50"2.75"3.5"2.26"13" or 24"UL ListedUL File # R18795 and E984292 Hour Ceiling Fire RatedMaterial is PolycarbonateUL Category Codes CEYY, QBWY and QCMZ20 Cubic Inches VolumeFixture Weight 50 lbs. MaximumFort Worth, TEXAS®LISTED®INC.EZ20CH.ai 11/02/2011 11:46:38 AM EZ20CN CEILING BOXDrawn By: D.S. Frank1-30-20092.3"2.23"3.50"3.83"2.75"3.5"2.83"UL ListedUL File # R18795 and E984292-Hour Ceiling Fire RatedMaterial is PolycarbonateUL Category Codes CEYY, QBWY and QCMZ20 Cubic Inches VolumeFixture Weight is 50 lbs. MaximumFort Worth, TEXAS®INC.2-HR-W-CEZ20CN.ai 11/02/2011 11:34:40 AM Outlet Boxes T&B Catalog Number: RN-23 UPC Number:78635880085 Status:Active Description: 1-gang 22.5 cu.in. blue thermoplastic outlet box with recessed angled nails. Features PVC construction for easier installation, greater per- formance and lower installation cost Application Designed and listed for use with non-metallic sheathed cable in accordance with Article 314 of the National Electrical Code All PVC boxes are permissible for use with 90 de- gree C connectors. General Material Non-Metallic Color Blue Wiring System Non-metallic sheathed cable Volume (cu.in.)22.5 Work New Mounting Method Recessed Angled Nails Number of Gangs One Dimension Information Length (inches)3 21/32 Width (inches)2 5/16 Depth (inches)3 3/8 Packaging T&B Order Multiple 100 Package in Units 100 T&B Sold in UOM Each T&B Weight Per UOM 24.25 lbs. per 100 Application Support Product Overview-Carlon Blue PVC Box- es Available on Website Certifications RoHS Compliance Yes Certifications File Nbr: E 11461 For further technical assistance, please contact us...