Loading...
HomeMy WebLinkAboutCofO Reports (2) CofO Application/CofO Application Form.pdf CofO Application/CofO Application Instructions.pdf CofO Application/WEH CofO Application.pdf CofO As-Builts/Architectural As-Builts.pdf W W W W W W D D D D D D UP UP 3 a400 3 a400 2 a400 2 a400 1 a400 1 a400 600 SF MECHANICAL AND ELECTRICAL 010 CORRIDOR 100C 104 SF ELMSHADE MED. ROOM 007 136 SF PROGRAM MANAGER'S OFFICE 006A 430 SF ELMSHADE OFFICES 006 51 SF STAFF TOILET 005 233 SF SHARED COPY / FILES 004 141 SF SUPPORTIVE HOUSING OFFICE 002E 472 SF HORIZON PROGRAM 002A 92 SF HORIZON MED. ROOM 002B 120 SF RECEPTION OFFICE 003 100 SF HORIZON WAITING AREA 002123 SF VESTIBULE 001 341 SF CONFERENCE ROOM 018 313 SF COMMON LAUNDRY 017 53 SF MEN'S TOILET 016 57 SF WOMEN'S TOILET 015 193 SF STAFF BREAK ROOM 014 206 SF COMMUNITY KITCHEN 013 802 SF COMMUNITY ROOM 012 120 SF VESTIBULE 100D 60 SF TRASH / RECYCLE 011 a600 2 a600 1 104 SF PROGRAM MANAGER'S OFFICE 002C 107 SF DIRECTOR'S OFFICE 002D A/V a606 1B a606 1A C L E A R 6'-1 3/4" 016.01 017.01 002A.01 002B.01 002C.01 002D.01 004.01 004.02 006.01 007.02 009.01 015.01 014.01 006A.01002E.01 013.01 C2 C1 S2 FS3 S4 C3 FS6 FS1 S5 FS7 A01.01 011.01 101.01 102.01 B01.01 010.01 007.01 101.03 101.02 101.07 101.06 101.08 102.06 102.08 102.04101.04 102.03 005.01 B01.02 102.07 102.02 661 SF (TYPE 2A) 1-BEDROOM APARTMENT 104 668 SF (TYPE 2A) 1-BEDROOM APARTMENT 103 668 SF (TYPE 2A) 1-BEDROOM APARTMENT 102 711 SF (TYPE 1A) 1-BEDROOM APARTMENT 101 104.01 104.04 104.08 104.06 104.03 104.02 104.07 KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY 269 SF STAIR B B01 234 SF STAIR A A01 ELEVATOR 101.05 102.05 104.05 2A 3 a503 103.04 103.06 103.08 103.01 103.02103.03 103.07 103.05 2A 2A 2A2A 2A 2A 2A 008.01 48 SF SERVER 008 100 SF BUILDING MAINTENANCE OFFICE 009 1 a501 2A 2A 2A 2A 5A 5 5A 5 5 2A 2A 1 1 2A 1 2 2A 2A 2A 1A 2A 1 2A2A 2A2A2A 12345677.68910111213141516 A A.5 B B.1 C D E F G H I 10'-0"10'-0"8'-7" 22'-6" 6'-0 3/4" 5'-11 1/2" 6'-0" FS2 2 a501 2 a502 002.01 018.01 018.02 012.01 012.02 100D.02 100C.01 001.02 1B 1A 2A 1A 23 4 4 TYP. 5 TYP. 5 TYP. 5 ALIGN TYP. TYP. 5 TYP. 5 TYP. 5 6 7 8 9 9 2A 9 9 16 ALIGN 13 13 CLEAR 9'-6 1/2" ALIGN 39'-5 7/8" 2A TYP. 5 S3 FS5 ALIGN 34'-3 1/2" 9'-10 1/4" 31'-1" 10'-2 1/2" 29'-4 1/4" 11'-4 1/2" ALIGN ALIGN 19'-3 3/4"5'-4 3/4" C L E A R 10'-0" 2A 2A 2A ALIGN ALIGN 11 2A FS4 4'-5" ALIGN 5'-4 1/2"12'-4 1/4" 22'-5 1/4" 8'-9 1/2"13'-4 1/2" ALIGN 13'-10 1/2" 8'-0" T Y P . 8 1/2" a605 1 a605 3 a605 2 003.01 11'-3 3/4"9'-5 1/4"12'-8" 24'-6 1/2" 17 17 7'-11" 10 10 9'-6" 10 10 10 001.01 5'-3 1/2" 4'-8 3/4" 3'-4" 6'-8" 3'-4" 3'-4" 3'-4" 2'-11 1/2" 3'-4" 3'-4" 3'-4" 6'-8" 3'-4" 4'-8 3/4" 4'-0"3'-4"6'-8"3'-4"3'-4"3'-4"6'-8"3'-4"14'-8"3'-4"4'-8 3/4" 2'-0"3'-4"1'-4"3'-4"1'-4"3'-4"1'-4"2 '-4"2'-4"3'-4"7'-4"3'-4"5'-0"2'-4"1'-4"3'-4"1'-4"3'-4"1'-4"3'-4"2'-8"3'-4"1'-4"3'-4"1'-4"3'-4"1'-4"2'-4"5'-0"3'-4"6'-0"3'-4"3'-8"2'-4"2'-0"3'-4"1'-4"3'-4"1'-4"3'-4" 2'-1 3/4" 25'-4 1/2"6'-0 1/2"25'-4 1/2" 2'-0"4'-0"14'-7 3/4"3'-4"2'-8"3'-4"2'-8"3'-4"2'-8"3'-4"5'-4"3'-4"6'-8"3'-4"2'-8"3'-4"2'-8"3'-4"2'-8"3'-4"2'-8"3'-4"2'-8"3'-4"14'-8"3'-4"2'-8"3'-4"2'-8"3'-4"2'-8"3'-4"4'-8 3/4" MAILBOXES 19 20 100D.01 TYP. 14TYP. 14 TYP. 15 TYP. 15 2A 2A1A 1A 2A 2A 2A 24 2A 2A 12 4'-9" 1 6'-2 1/4"6'-9 1/2" 18 SF CUST. 020 2A3'-0" 1 1 1 11 2A 2A2A 1 2A 1 2 1B 1B 1 1B 1B 11 1 1 1A 1A 21A 1 1 1 1 1B1B 1 1 11 1 1B 1A 1 1 1B 22 1 1 8 3'-2" 22 4B23 1A 1A 4B 020.01 3 a501 1 a502 a503 5 10 6 SK-2 2 SK-1 1 4 3/4" 24'-0 3/8" 2A 10'-7 1/2" ALIGN 11 1 1 GENERAL NOTES[FLOOR PLANS] 1. ALL DIMENSION STRINGS FOR WOOD FRAMED ROUGH OPENINGS IN EXTERIOR WALLS ARE TAKEN FROM OUTSIDE FACE OF WOOD STUD AT INSIDE AND OUTSIDE CORNERS, U.N.O.. 2. REFER TO ENLARGED PLANS FOR APARTMENT UNIT DIMENSIONS U.N.O. KEYNOTES[FLOOR PLANS] 1-HOUR FIRE-RATED, SEMI-RECESSED, FIRE EXTINGUISHER CABINET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT EXTINGUISHER TYPE & LOCATION WITH LOCAL FIRE MARSHAL. MOUNT CABINET AT 5-1/2" A.F.F. MEASURED TO BOTTOM OF CABINET. WALL-MOUNTED FIRE EXTINGUISHER BRACKET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT FIRE EXTINGUISHER TYPE WITH THE LOCAL FIRE MARSHAL. MOUNT FIRE EXTINGUISHER AT 48" A.F.F. MEASURED TO TOP OF EXTINGUISHER. PROVIDE 1/2-INCH PLYWOOD AT ELECTRICAL ROOM TO ACCOMMODATE ELECTRICAL EQUIPMENT, THIS WALL. PROVIDE FIRE-RATED ELECTRONIC COMMUNICATION SPEAKER AT RECEPTION AREA. 16-INCH HIGH (ALIGN WITH TOP OF BOTTOM MOST CURTAIN WALL MULLION), 2 1/2-INCH, 20-GAUGE METAL STUD LOW WALL WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUDS OFF FROM CURTAIN WALL 1-INCH AND PROVIDE CLOSED CELL SPRAY FOAM INSUALTION FULL CAVITY OF STUDS. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. COLUMN ENCLOSURE: PROVIDE 2 1/2-INCH, 16-GAUGE METAL STUD FRAMING WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUD FRAMING OFF STRUCTURAL STEEL COLUMN 2INCHES TO CLEAR FIRE-PROOFING. WHERE APPLICABLE, ALIGN GYPSUM BOARD WITH ADJACENT GYPSUM WALL BOARD FOR AN EVEN AND CONTIGUOUS FINISH. PROVIDE & INSTALL UTILITY OR MOP SINK THIS LOCATION, SEE PLUMBING DRAWINGS. PROVIDE & INSTALL WASHER & DRYER EQUIPMENT THIS ROOM, SEE ELECTRICAL DRAWINGS, HVAC DRAWINGS, & SPECIFICATIONS. PROVIDE FOUR (4) BENCHES EQUAL TO WADDELLS METAL BENCH (SIZE: 54"L x 14"D x 17"H). BLACK STEEL FRAME WITH SOLID WOOD CLEAR MAPLE TOP. SKU: W000437032. PROVIDE & INSTALL AUTOMATIC DOOR OPERATOR AND ASSOCIATED POWER, CABLING, ETC., THIS LOCATION, SEE ELECTRICAL DRAWINGS & DOOR HARDWARE. DOOR ACTUATOR SHALL COMPLY WITH ANSI A117.1. PIPE CHASE: PROVIDE & INSTALL 5/8" TYPE-X GYPSUM BOARD SHEATHING OVER STUD FRAMING (METAL STUDS AT GROUND FLOOR, WOOD STUDS FLOORS 2 THROUGH 5) (FLAT STUD) TO ACCOMMODATE PIPING, SEE PLUMBING AND ASSD SYSTEM DRAWINGS. FIRESTOP ALL PENETRATIONS THROUGH FIRE-RATED FLOOR/CEILING ASSEMBLIES. SEMI-RECESSED, WALL-MOUNTED INTERCOM SYSTEM, SEE ELECTRICAL DRAWINGS. MAINTAIN FIRE-RATING OF WALL. FULLY INSULATED AND GASKETED EXTERIOR DOOR, SEE DOOR SCHEDULE. COORDINATE EXACT ELEVATION OF DOOR WITH FLOOR / ROOF ELEVATION, SEE DETAIL. PROVIDE WOOD FRAMED STAIR WITH JOHNSONITE RUBBER STAIR TREADS, INTEGRAL NOSING AND LANDINGS TO MATCH. WOOD FRAMING SHALL HAVE CONTINUOUS VAPOR SEPERATION MEMBRANE FROM CMU SHAFT RAISED PLATFORM AT APARTMENT UNIT MECHANICAL ROOMS FOR VRP UNIT. PROVIDE 3-5/8" 20-GAUGE METAL STUD FRAMING AT GROUND FLOOR AND 2x4 WOOD STUD FRAMING AT FLOORS 2 THROUGH 5. PROVIDE MINERAL WOOD BATT INSULATION IN CAVITY FOR SOUND ISOLATION. RAISED PLATFORM SHALL PROVIDE PROPER ELEVATION TO MECHANICAL UNIT AS TO ALIGN WALL PENETRATION WITH EXTERIOR CLADDING SYSTEM. PROVIDE AND INSTALL CLOSET SHELVING, SEE SPECIFICATIONS. PROVIDE 3 5/8-INCH METAL STUDS WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD CORRIDOR SIDE UP TIGHT TO UNDERSIDE OF DECK. ALIGN GYPSUM WALL BOARD TO ALIGN WITH ADJACENT FURRING AT PILASTER. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. WALL AND WINDOWS ARE RECESSED AT THIS LOCATION, 3-5/8-INCH CLEAR FROM FRAME OF WINDOW TO EXTERIOR CLADDING, SEE DETAILS. RECESSED, WALL-MOUNTED VERTICAL MAILBOXES EQUAL TO 2B GLOBAL, INC.: USPS COLLECTION MODEL. PROVIDE ONE (1)MAILBOX FOR EACH APARTMENT UNIT (SIXTY (60) MAILBOXES TOTAL), TWO (2) ADDITIONAL MAILBOXES (ONE (1) FOR EACH COMMERCIAL TENANT), AND FOUR (4) PARCEL BOXES. FINISH SHALL BE NATURAL ANODIZED WITH ENGRAVED DOOR I.D., COORDINATE LABELING WITH OWNER AND ARCHITECT PRIOR TO ORDERING MAILBOXES. INSTALL ALL FRAMING AND BLOCKING AS REQUIRED TO ACCMMODATE INSTALLATION OF MAILBOXES. INSTALL MAILBOXES TO COMPLY WITH ANSI A117.1 FOR ACCESSIBILITY. PROVIDE AND INSTALL WALL-MOUNTED, HIGH / LOW ELECTRIC WATER COOLERS AND BOTTLE FILLING STATION, SEE PLUMBING DRAWINGS. WATER COOLERS SHALL COMPLY WITH ANSI A117.1. PROVIDE 1-HOUR FIRE-RESISTANCE-RATED PARTITION WALL TIGHT TO UNDERSIDE OF STAIR AT LOWEST LEVEL, TO PREVENT ACCESS TO OR ANY STORAGE BENEATH THE STAIR. PROVIDE AND INSTALL 42-INCH HIGH PARTIAL HEIGHT WALL (WALL TYPE 1) WITH 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. PROVIDE AND INSTALL 32-INCH DEEP HPL WORKSURFACE AT 30-INCH A.F.F.. PROVIDE GUSSET SUPPORT AT 3 POINTS. PROVIDE AND INSTALL HPL CLOTHES FOLDING COUNTERTOP AT 30-INCH A.F.F.. FINISHED FLOORS SHALL SEAMLESSLY ALIGN. COORDINATE EXACT FINISH FLOOR ELEVATION BETWEEN CORRIDOR AND STAIR LANDINGS. 1A 1B 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 # WALL ASSEMBLY, SEE WALL SCHEDULE. CONCRETE WALL, SEE STRUCTURAL DRAWINGS. CMU WALL, SEE STRUCTURAL DRAWINGS. WINDOW / STOREFRONT / CURTAIN WALL, SEE ASSOCIATED SCHEDULES. NEW DOOR, SEE DOOR SCHEDULE. ACCESSIBLE APARTMENT: ACCESSIBLE TO MOBILITY IMPAIRED, SEE ENLARGED PLANS. AUDIBLE / VISUAL APARTMENT: ACCESSIBLE TO HEARING OR VISUALLY IMPAIRED, SEE ELECTRICAL DRAWINGS. LEGEND[REFLECTED CEILING PLANS] 000.01 S10 A/V INTERIOR WALL ASSEMBLY SCHEDULENOTE:PROVIDE CONTINUOUS FIREBLOCKING ABOVE ALL DIMISING WALLS THAT DO NOT EXTEND TO UNDERSIDE OF DECK ABOVE. WALL TYPE 20-GAUGE, 3-5/8" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 4 7/8" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPESAME AS WALL TYPE 1, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 1A 1 WALL TYPE2 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 1/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK WALL TYPE3 2x4 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 FLOOR TO DECK WALL TYPESAME AS WALL TYPE 3, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 3A WALL TYPE4 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 OR GREATER FLOOR TO DECK 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. ROOM SIDE SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 0' - 6 3/4" 0' - 4 3/4" WALL TYPE4AUL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U311 1-HOUR FIRE-RATED 51 OR GREATER FLOOR TO DECK ROOM SIDE 0' - 7 3/4" 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL. 7/16" THICK ORIENTED STRAND BOARD (OSB) SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPE5 8" CMU, SEE STRUCTURAL DRAWINGS. 5/8" TYPE-X GYPSUM BOARD SHEATHING, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U904 3-HR / 2-HR FIRE-RATED 50 FULL HEIGHT OF SHAFT SHAFT SIDE 20-GAUGE, 7/8" METAL FURRING @ 24" O.C., TYPICAL 0' - 9 5/32" WALL TYPESAME AS WALL TYPE 1, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., BEDROOM SIDE. 1B WALL TYPESAME AS WALL TYPE 3, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C. 3B WALL TYPE SAME AS WALL TYPE 5, EXCEPT WITH: 20-GAUGE, 2-1/2" METAL STUD FRAMING @ 24" O.C. (IN LIEU OF 7/8" METAL FURRING) 5A WALL TYPE2A 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 3/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL, CORRIDOR SIDE. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U419 -NON-COMBUSTIBLE 1-HOUR FIRE-RATED 53 FLOOR TO DECK ROOM SIDE WALL / CEILING ASSEMBLY NOTES: 1. ALL PENETRATIONS THRU FIRE RATED ASSEMBLIES (WALL OR CEILING) MUST BE FIRESTOPPED TO THE RATING LEVEL OF THE ASSEMBLY. 2. ALL TRADES TO SUBMIT FIRESTOPPING SCHEDULE FOR ALL PENETRATIONS PRIOR TO COMMENCING WORK PER SPECIFICATIONS 078400 FIRESTOPPING. 3. PROVIDE MARKING AND IDENTIFICATION AT ALL ACCESSIBLE CONCEALED FLOOR, OR FLOOR/CEILINGS TO IDENTIFY FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS OR SMOKE PARTITIONS PER SECTIONS 703.7 OF THE 2015 IBC. 4. ALL BOTTOM PLATES IN CONTACT WITH MASONRY/CONCRETE SHALL BE PRESSURE TREATED WITH SILL SEALER. 5. FOR ALL METAL STUD FRAMING ASSUME 20-GAUGE FOR BIDDING PURPOSES UNLESS OTHERWISE NOTED. ACTUAL GAUGE SHALL BE ENGINEERED BY CONTRACTOR. NOTE:ALL WALL PARTITIONS SHALL HAVE A DOUBLE TOP PLATE, ENTIRE BUILDING, TYPICAL. WALL TYPESAME AS WALL TYPE 4, EXCEPT STAGGER STUDS TO MATCH WIDTH BETWEEN STAIRS AS DELINEATED ON STAIR PLANS. 4B WALL TYPE6UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U417 2-HR FIRE-RATED N/A FULL HEIGHT OF SHAFT 1" THICK TYPE-X GYPSUM BOARD SHAFTLINER 1-1/2" WIDE X 2-1/2" DEEP 'C-T' SHAPED .019" THICK GALVANIZED METAL STUDS SHAFT SIDE TWO (2) LAYERS OF 5/8" TYPE-X GYSUM BOARD SHEATHING 3 3/4" STEEL COLUMN STAND-OFF METAL STUDS 2" FROM FACE OF FIRE-PROOFING ON STEEL COLUMN SEE STRUCTURAL plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. PLAN PROJECT No. DATE ©PLAN ARCHITECTURAL STUDIO, PC SHARS I.D. # 20186081 a101 GROUND FLOOR PLAN 001.16.01.02 11.22.2019 LAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 CONSTRUCTION PERMIT DOCUMENTS SCALE: 1/8" = 1'-0" GROUND FLOOR PLAN 1 N SCALE: 1 1/2" = 1'-0" PLAN DETAIL 2 1RFI 028 - GROUND FLOOR LOUVERS06.17.2020 29'-3 1/2" 17'-10 1/8" 22'-6 3/4" 16'-6 3/4" 14'-3" 12'-3 1/4" 10'-2 3/4" 5'-3 3/8" 6'-8" 10'-8 1/8" 10' 3" 9'-4 3/4" 9'-8 3/4" 30'-8 1/4" 13'-6" 13'-5 7/8" 10'-4 3/8" 13'-6 1/8" 34'-3 3/8" 9'-4 7/8" 7'-3 5/8" 5'-11 5/8" 8'-5 5/8" 9'-4 3/4" 22'-8 7/8" 10'-1 1/4" 9' 1 3/8" 9' 2 3/8" 9'-8 3/4" 7'-9" 8'-2 3/8" 9'-4 1/2" 9'-4 1/8" 11'-2 1/4" 8'-5 3/4" 11'-4" 9'-7 1/2" 12'-6 3/8" 25'-3 5/8" 12'-8 5/8" 6'-0 1/2" 7'-10 3/4" 9'-11" 10'-3 1/2" 19'-2 7/8" 39'-7 7/8" 14'-4 3/8" 12'-7 3/8" 14'-4 3/8" 11'-8 1/8" 7'-7 1/4" 7'-1 1/4" 7'-1 1/4" 7'-1 1/4" 10'-11 1/8" 24'-4 1/8" 6'-8" 23'-5 1/4" 15'-3 1/4" 5'-7 7/8" 19' 7" 6'-3 3/4" 11'-5 3/8" 9'-6 3/8" 13'-6 1/2" 23'-5 1/8" 14'-0 1/4" 5'-8 3/8" 17' 10 7/8" 6'-1 3/4" 11'-5 1/2" 9'-1 7/8" 13'-1 5/8" 23'-5 1/8" 14'-2 3/4" 5'-8 5/8" 17'-10 7/8" 6'-3 3/4" 11'-5 1/4" 8'-11" 12'-10 7/8" 22'-6 3/4" 14'-0 7/8" 5'-8 1/8" 17'-1 3/8" 6'-2 3/4" 11'-4 7/8" 9'-1 1/4" 13'-1" DN UP DN UP 3 a400 3 a400 2 a400 2 a400 1 a400 1 a400 a606 2B a606 2A 202.07 202.08 202.06 202.04 202.02202.01 202.03 201.06 201.08 201.07 201.03 201.01 201.04 201.02 C4 C6 C5 C2 C1 715 SF (TYPE 2) 1-BEDROOM APARTMENT 205 673 SF (TYPE 2) 1-BEDROOM APARTMENT 207 673 SF (TYPE 2) 1-BEDROOM APARTMENT 211 CUST. 217 729 SF (TYPE 2) 1-BEDROOM APARTMENT 214 280 SF STAIR B B02 749 SF (TYPE 2) 1-BEDROOM APARTMENT 212 673 SF (TYPE 2) 1-BEDROOM APARTMENT 210 673 SF (TYPE 2) 1-BEDROOM APARTMENT 208 672 SF (TYPE 2) 1-BEDROOM APARTMENT 206 670 SF (TYPE 2) 1-BEDROOM APARTMENT 204 658 SF (TYPE 2) 1-BEDROOM APARTMENT 203 685 SF (TYPE 4) 1-BEDROOM APARTMENT 202 755 SF (TYPE 3) 1-BEDROOM APARTMENT 201 234 SF STAIR A A02 62 SF TRASH / RECYCLE 215 215 SF RECEPTION LOUNGE 200A 1623 SF CORRIDOR 200 KITCHEN LIVING ROOMBEDROOM BATH ENTRY LIN. STORAGE COATSCLOSET MECH. KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY BEDROOM CLOSET LIN. COATS MECH. LIVING ROOM KITCHEN ENTRY STOR. BATH LIVING ROOM BEDROOM MECH. KITCHEN STOR. ENTRY BATH COATS CLOSET KITCHEN COATS STOR. CLOSET MECH. LIVING ROOM BEDROOM BATH ENTRY 205.01 205.03 205.02 205.07 205.04 205.06 205.08 207.04 207.06 207.08 207.03 207.02 207.07 209.07 209.02209.03 209.04 209.06 209.08 211.08 211.06 211.04 211.03 211.02 211.07 213.07 213.03 213.01 213.02 213.04 213.06 213.08 214.06 214.08 214.04 214.07 214.01 214.03214.02 210.06 210.08 210.04 210.07 210.02 210.03 208.03208.02 208.07 208.06 208.08 208.04206.04 206.06 206.08 206.07 206.02 206.03 204.07 204.02 204.01 204.06 204.08 204.04 204.03 203.06 203.08 203.04 203.01 203.02 203.03 203.05 203.07 205.05 207.05 209.05 211.05 213.05 214.05 210.05 208.05 206.05 204.05 STOR. BATH CLOSET ENTRY KITCHEN BEDROOM LIVING ROOM MECH. LIN. COATS I.T. CLOSET 216 216.01 217.01 B02.01 215.01 A02.01 732 SF (TYPE 2) 1-BEDROOM APARTMENT 213 ELEVATOR 2 a503 3 a503 673 SF (TYPE 2) 1-BEDROOM APARTMENT 209 211.01 209.01 207.01 206.01 208.01 210.01 1 a501 4A4A4A4A 4A 4A 5 5A 4A 4A 4A 4A4A4A4A 3B 5 4A 4A 4A4A 4A 3B 3B 3B 3B 12345677.68910111213141516 A A.5 B B.1 C D E F G H I A/V 2 a501 2 a502 202.05 LIN. LIN. 201.05 2'-0 1/2" 3'-0"1'-6"3'-0"28'-2 1/4"2'-4"6'-0 1/4"3'-0"1'-6"3'-0" 2'-0 1/2" 2'-0 1/2" 3'-0"1'-6"3'-0"8'-1 3/4"2'-4"1'-6" 3'-0"2'-1 3/4" 1'-11 1/2" 3'-0"1'-6"3'-0"1'-6"3'-0"2'- 5"2'-4"3'-5 3/4"3'-0"8'-2 3/4"3'-0"1'-6"3'-0"1'-6"3'-0"2'-7"2'-4"2'-7"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0"3'-0"3'-0"1'-6"3'-0"1'-6"3'-0"2'-2"2'-4"3'-0"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0" 2'-11 1/4" 2'-0 1/2" 3'-0"1'-6"3'-0"15'-0 1/2"6'-5"15'-0 3/4"3'-0"1'-6"3'-0" 2'-0 1/2" 11 1/2" 2'-0 1/2" 3'-0"1'-6"3'-0"1'-6"3'-0"1'-7"2'-4"3'-7"3'- 0" 2'-11 1/2" 3'-0"19'-6"3'-0"1'-6"3'-0"1'-6"3'-0"3'-2"2'-4"2'-0"3'-0"8'-11 1/2"3'-0"3'-8"2'-4"1'-6"3'-0"1'-6"3'-0"1'-6"3'-0"3'-0 1/2"3'-0"1'-6"3'-0"1'-6"3'-0"2'-7"2'-4"2'-7"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0" 1'-7 1/2" 11'-0 3/4"4'-1 3/4"3'-0"3'-4"2'-4"3'-4"3'-0"6'-0"4'-2" 2'-0 1/2" 3'-0"1'-6"3'-0"6'-0"3'-0"6'-0"3'-0"1'-6"3'-0"1'-6"3'-0"2'-2"2'-4"1'-6"3'- 0"5'-8 1/2"6'-4 1/4"13'-0 1/4"3'-0"4'-5 3/4"4'-2" 5'-6 1/4" 4'-8 1/4" 10 10 10 10 13 13 TYP. 14 TYP. 14 TYP.14 TYP.15 TYP.15 TYP. 15 5'-0 1/4" 2'-10 1/2" CLEAR 6'-2 1/4" CLEAR 6'-0 1/2" C L E A R 6'-1 3/4" CLEAR 10'-10" C L E A R 6'-1 3/4" 14'-1 3/4"17'-3 1/2" 9'-6" 3'-0" 4'-0" 14'-10 3/4"16'-5 1/2" 9'-0" 5'-0" 8'-8" 3'-0" 4'-0" 3'-9 1/2" 9'-0" 4'-0" 18 18 4A 4A 1A 1A 1A a503 6 25 3 a501 1 a502 10 10 10 6 1 a503 a503 4 4A4A4A 5A 4B 25 25 13'-7"9'-0" 212.03 212.07 212.02 212.04 212.06 212.08 212.05 212.01 4A INSIDE CLR. 8 1/2" 4 3A 4'-0"CLR. 3B 212.09 STOR. 6 6 6 4'-2 1/2" GENERAL NOTES[FLOOR PLANS] 1. ALL DIMENSION STRINGS FOR WOOD FRAMED ROUGH OPENINGS IN EXTERIOR WALLS ARE TAKEN FROM OUTSIDE FACE OF WOOD STUD AT INSIDE AND OUTSIDE CORNERS, U.N.O.. 2. REFER TO ENLARGED PLANS FOR APARTMENT UNIT DIMENSIONS U.N.O. KEYNOTES[FLOOR PLANS] 1-HOUR FIRE-RATED, SEMI-RECESSED, FIRE EXTINGUISHER CABINET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT EXTINGUISHER TYPE & LOCATION WITH LOCAL FIRE MARSHAL. MOUNT CABINET AT 5-1/2" A.F.F. MEASURED TO BOTTOM OF CABINET. WALL-MOUNTED FIRE EXTINGUISHER BRACKET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT FIRE EXTINGUISHER TYPE WITH THE LOCAL FIRE MARSHAL. MOUNT FIRE EXTINGUISHER AT 48" A.F.F. MEASURED TO TOP OF EXTINGUISHER. PROVIDE 1/2-INCH PLYWOOD AT ELECTRICAL ROOM TO ACCOMMODATE ELECTRICAL EQUIPMENT, THIS WALL. PROVIDE FIRE-RATED ELECTRONIC COMMUNICATION SPEAKER AT RECEPTION AREA. 16-INCH HIGH (ALIGN WITH TOP OF BOTTOM MOST CURTAIN WALL MULLION), 2 1/2-INCH, 20-GAUGE METAL STUD LOW WALL WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUDS OFF FROM CURTAIN WALL 1-INCH AND PROVIDE CLOSED CELL SPRAY FOAM INSUALTION FULL CAVITY OF STUDS. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. COLUMN ENCLOSURE: PROVIDE 2 1/2-INCH, 16-GAUGE METAL STUD FRAMING WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUD FRAMING OFF STRUCTURAL STEEL COLUMN 2INCHES TO CLEAR FIRE-PROOFING. WHERE APPLICABLE, ALIGN GYPSUM BOARD WITH ADJACENT GYPSUM WALL BOARD FOR AN EVEN AND CONTIGUOUS FINISH. PROVIDE & INSTALL UTILITY OR MOP SINK THIS LOCATION, SEE PLUMBING DRAWINGS. PROVIDE & INSTALL WASHER & DRYER EQUIPMENT THIS ROOM, SEE ELECTRICAL DRAWINGS, HVAC DRAWINGS, & SPECIFICATIONS. PROVIDE FOUR (4) BENCHES EQUAL TO WADDELLS METAL BENCH (SIZE: 54"L x 14"D x 17"H). BLACK STEEL FRAME WITH SOLID WOOD CLEAR MAPLE TOP. SKU: W000437032. PROVIDE & INSTALL AUTOMATIC DOOR OPERATOR AND ASSOCIATED POWER, CABLING, ETC., THIS LOCATION, SEE ELECTRICAL DRAWINGS & DOOR HARDWARE. DOOR ACTUATOR SHALL COMPLY WITH ANSI A117.1. PIPE CHASE: PROVIDE & INSTALL 5/8" TYPE-X GYPSUM BOARD SHEATHING OVER STUD FRAMING (METAL STUDS AT GROUND FLOOR, WOOD STUDS FLOORS 2 THROUGH 5) (FLAT STUD) TO ACCOMMODATE PIPING, SEE PLUMBING AND ASSD SYSTEM DRAWINGS. FIRESTOP ALL PENETRATIONS THROUGH FIRE-RATED FLOOR/CEILING ASSEMBLIES. SEMI-RECESSED, WALL-MOUNTED INTERCOM SYSTEM, SEE ELECTRICAL DRAWINGS. MAINTAIN FIRE-RATING OF WALL. FULLY INSULATED AND GASKETED EXTERIOR DOOR, SEE DOOR SCHEDULE. COORDINATE EXACT ELEVATION OF DOOR WITH FLOOR / ROOF ELEVATION, SEE DETAIL. PROVIDE WOOD FRAMED STAIR WITH JOHNSONITE RUBBER STAIR TREADS, INTEGRAL NOSING AND LANDINGS TO MATCH. WOOD FRAMING SHALL HAVE CONTINUOUS VAPOR SEPERATION MEMBRANE FROM CMU SHAFT RAISED PLATFORM AT APARTMENT UNIT MECHANICAL ROOMS FOR VRP UNIT. PROVIDE 3-5/8" 20-GAUGE METAL STUD FRAMING AT GROUND FLOOR AND 2x4 WOOD STUD FRAMING AT FLOORS 2 THROUGH 5. PROVIDE MINERAL WOOD BATT INSULATION IN CAVITY FOR SOUND ISOLATION. RAISED PLATFORM SHALL PROVIDE PROPER ELEVATION TO MECHANICAL UNIT AS TO ALIGN WALL PENETRATION WITH EXTERIOR CLADDING SYSTEM. PROVIDE AND INSTALL CLOSET SHELVING, SEE SPECIFICATIONS. PROVIDE 3 5/8-INCH METAL STUDS WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD CORRIDOR SIDE UP TIGHT TO UNDERSIDE OF DECK. ALIGN GYPSUM WALL BOARD TO ALIGN WITH ADJACENT FURRING AT PILASTER. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. WALL AND WINDOWS ARE RECESSED AT THIS LOCATION, 3-5/8-INCH CLEAR FROM FRAME OF WINDOW TO EXTERIOR CLADDING, SEE DETAILS. RECESSED, WALL-MOUNTED VERTICAL MAILBOXES EQUAL TO 2B GLOBAL, INC.: USPS COLLECTION MODEL. PROVIDE ONE (1)MAILBOX FOR EACH APARTMENT UNIT (SIXTY (60) MAILBOXES TOTAL), TWO (2) ADDITIONAL MAILBOXES (ONE (1) FOR EACH COMMERCIAL TENANT), AND FOUR (4) PARCEL BOXES. FINISH SHALL BE NATURAL ANODIZED WITH ENGRAVED DOOR I.D., COORDINATE LABELING WITH OWNER AND ARCHITECT PRIOR TO ORDERING MAILBOXES. INSTALL ALL FRAMING AND BLOCKING AS REQUIRED TO ACCMMODATE INSTALLATION OF MAILBOXES. INSTALL MAILBOXES TO COMPLY WITH ANSI A117.1 FOR ACCESSIBILITY. PROVIDE AND INSTALL WALL-MOUNTED, HIGH / LOW ELECTRIC WATER COOLERS AND BOTTLE FILLING STATION, SEE PLUMBING DRAWINGS. WATER COOLERS SHALL COMPLY WITH ANSI A117.1. PROVIDE 1-HOUR FIRE-RESISTANCE-RATED PARTITION WALL TIGHT TO UNDERSIDE OF STAIR AT LOWEST LEVEL, TO PREVENT ACCESS TO OR ANY STORAGE BENEATH THE STAIR. PROVIDE AND INSTALL 42-INCH HIGH PARTIAL HEIGHT WALL (WALL TYPE 1) WITH 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. PROVIDE AND INSTALL 32-INCH DEEP HPL WORKSURFACE AT 30-INCH A.F.F.. PROVIDE GUSSET SUPPORT AT 3 POINTS. PROVIDE AND INSTALL HPL CLOTHES FOLDING COUNTERTOP AT 30-INCH A.F.F.. FINISHED FLOORS SHALL SEAMLESSLY ALIGN. COORDINATE EXACT FINISH FLOOR ELEVATION BETWEEN CORRIDOR AND STAIR LANDINGS. 1A 1B 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 # WALL ASSEMBLY, SEE WALL SCHEDULE. CONCRETE WALL, SEE STRUCTURAL DRAWINGS. CMU WALL, SEE STRUCTURAL DRAWINGS. WINDOW / STOREFRONT / CURTAIN WALL, SEE ASSOCIATED SCHEDULES. NEW DOOR, SEE DOOR SCHEDULE. ACCESSIBLE APARTMENT: ACCESSIBLE TO MOBILITY IMPAIRED, SEE ENLARGED PLANS. AUDIBLE / VISUAL APARTMENT: ACCESSIBLE TO HEARING OR VISUALLY IMPAIRED, SEE ELECTRICAL DRAWINGS. LEGEND[REFLECTED CEILING PLANS] 000.01 S10 A/V INTERIOR WALL ASSEMBLY SCHEDULENOTE:PROVIDE CONTINUOUS FIREBLOCKING ABOVE ALL DIMISING WALLS THAT DO NOT EXTEND TO UNDERSIDE OF DECK ABOVE. WALL TYPE 20-GAUGE, 3-5/8" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 4 7/8" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPESAME AS WALL TYPE 1, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 1A 1 WALL TYPE2 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 1/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK WALL TYPE3 2x4 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 FLOOR TO DECK WALL TYPESAME AS WALL TYPE 3, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 3A WALL TYPE4 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 OR GREATER FLOOR TO DECK 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. ROOM SIDE SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 0' - 6 3/4" 0' - 4 3/4" WALL TYPE4AUL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U311 1-HOUR FIRE-RATED 51 OR GREATER FLOOR TO DECK ROOM SIDE 0' - 7 3/4" 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL. 7/16" THICK ORIENTED STRAND BOARD (OSB) SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPE5 8" CMU, SEE STRUCTURAL DRAWINGS. 5/8" TYPE-X GYPSUM BOARD SHEATHING, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U904 3-HR / 2-HR FIRE-RATED 50 FULL HEIGHT OF SHAFT SHAFT SIDE 20-GAUGE, 7/8" METAL FURRING @ 24" O.C., TYPICAL 0' - 9 5/32" WALL TYPESAME AS WALL TYPE 1, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., BEDROOM SIDE. 1B WALL TYPESAME AS WALL TYPE 3, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C. 3B WALL TYPE SAME AS WALL TYPE 5, EXCEPT WITH: 20-GAUGE, 2-1/2" METAL STUD FRAMING @ 24" O.C. (IN LIEU OF 7/8" METAL FURRING) 5A WALL TYPE2A 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 3/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL, CORRIDOR SIDE. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U419 -NON-COMBUSTIBLE 1-HOUR FIRE-RATED 53 FLOOR TO DECK ROOM SIDE WALL / CEILING ASSEMBLY NOTES: 1. ALL PENETRATIONS THRU FIRE RATED ASSEMBLIES (WALL OR CEILING) MUST BE FIRESTOPPED TO THE RATING LEVEL OF THE ASSEMBLY. 2. ALL TRADES TO SUBMIT FIRESTOPPING SCHEDULE FOR ALL PENETRATIONS PRIOR TO COMMENCING WORK PER SPECIFICATIONS 078400 FIRESTOPPING. 3. PROVIDE MARKING AND IDENTIFICATION AT ALL ACCESSIBLE CONCEALED FLOOR, OR FLOOR/CEILINGS TO IDENTIFY FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS OR SMOKE PARTITIONS PER SECTIONS 703.7 OF THE 2015 IBC. 4. ALL BOTTOM PLATES IN CONTACT WITH MASONRY/CONCRETE SHALL BE PRESSURE TREATED WITH SILL SEALER. 5. FOR ALL METAL STUD FRAMING ASSUME 20-GAUGE FOR BIDDING PURPOSES UNLESS OTHERWISE NOTED. ACTUAL GAUGE SHALL BE ENGINEERED BY CONTRACTOR. NOTE:ALL WALL PARTITIONS SHALL HAVE A DOUBLE TOP PLATE, ENTIRE BUILDING, TYPICAL. WALL TYPESAME AS WALL TYPE 4, EXCEPT STAGGER STUDS TO MATCH WIDTH BETWEEN STAIRS AS DELINEATED ON STAIR PLANS. 4B WALL TYPE6UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U417 2-HR FIRE-RATED N/A FULL HEIGHT OF SHAFT 1" THICK TYPE-X GYPSUM BOARD SHAFTLINER 1-1/2" WIDE X 2-1/2" DEEP 'C-T' SHAPED .019" THICK GALVANIZED METAL STUDS SHAFT SIDE TWO (2) LAYERS OF 5/8" TYPE-X GYSUM BOARD SHEATHING 3 3/4" plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. PLAN PROJECT No. DATE ©PLAN ARCHITECTURAL STUDIO, PC SHARS I.D. # 20186081 a102 SECOND FLOOR PLAN 001.16.01.02 11.22.2019 LAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 CONSTRUCTION PERMIT DOCUMENTS SCALE: 1/8" = 1'-0" SECOND FLOOR PLAN 1 N POST BID ADDENDUM #42020.01.31 A4 23'-9 7/8" 16'-1 3/8" 4'-9 1/4" 19'-4 1/4" 4'-5 3/4" 9'-6 3/8" 14'-1 3/4" 10'-1 3/4" 30'-1 7/8" 11'-8 1/4" 22'-3" 7'-8 1/8" 3'-9 1/4" 12'-6" 9'-11 5/8" 23'-3 1/4" 14'-4" 6'-1 1/4" 11'-2 1/4" 12'-7 1/2" 23'-4" 14'-8 1/8" 6'-5 3/8" 11'-6 1/2" 12'-10 1/4" 23'-7 3/4" 15'-4" 19'-8 7/8" 6'-5 1/8" 11'-6 1/8" 13'-5 5/8" 23'-7 3/8" 14'-4" 6'-5 1/8" 11'-6 1/8" 12'-9 7/8" 8'-11" 23'-7 1/2" 14'-4 1/8" 6'-5 1/8" 11'-6" 12'-9 1/2" 8'-10 3/4" 23'-7 3/8" 14'-3 3/4" 6'-5 1/4" 11'-6 1/4" 8'-10 5/8"" 12'-9 1/2" 23'-7 1/8" 14'-4 3/8" 6'-5" 11'-5 1/2" 12'-9 1/2" 8'-10 3/8" 23'-7 3/8" 14'-4 1/2" 6'-5 1/8" 11'-6 1/8" 12'-9 1/2" 8'-10 1/2" 23'-7" 14'-3 7/8" 6'-4 3/8" 11'-5" 12'-9 7/8" 8'-11" 23'-7" 14'-10 5/8" 6'-4 7/8" 11'-5 1/2" 16'-5 7/8" 12'-6 7/8" 23'-7 1/4" 14'-4" 18'-1 1/2" 11'-6 3/8" 6'-5 1/8" 8'-10 7/8" 12'-9 7/8" 11'-6 1/8" 23'-7 1/2" 14'-1 7/8" 5'-8 1/4" 17'-11 3/4" 6'-5 1/4" 17'-2 1/4" 11'-6 1/4" 13'-3 3/8" 5'-8" 8'-8 3/8" 6'-9 3/8" 5'-2 1/8" 17'-9 3/8" 8'-8 5/8" 18'-7 3/4" 5'-8 7/8" 8'-11 5/8" 5'-8 1/2" 9'-6 7/8" 5'-9" 18'-0 1/8" 5'-8 1/2" 17'-11 1/8" 5'-8 1/4" 17'-11 1/4" 5'-8 5/8" 17'-11 3/4" 5'-8 1/2" 17'-11 7/8" 5'-8 1/4" 17'-11 1/4" 17'-11 1/2" 5'-8 3/8" 5'-8 5/8" 18'-10 3/4" 5'-5 3/8" DN UP DN UP 3 a400 3 a400 2 a400 2 a400 1 a400 1 a400 a601 1 a602 1 a604 1 a603 1 A/V a606 3A a606 3B C4 C6 C5 715 SF (TYPE 1) 1-BEDROOM APARTMENT 305 673 SF (TYPE 2) 1-BEDROOM APARTMENT 307 673 SF (TYPE 2) 1-BEDROOM APARTMENT 311 KITCHEN LIVING ROOMBEDROOM BATH ENTRY LIN. STORAGE COATSCLOSET MECH. KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY BEDROOM CLOSET LIN. COATS MECH. LIVING ROOM KITCHEN ENTRY STOR. BATH LIVING ROOM BEDROOM MECH. KITCHEN STOR. ENTRY BATH COATS CLOSET KITCHEN COATS STOR. CLOSET MECH. LIVING ROOM BEDROOM BATH ENTRY STOR. BATH CLOSET ENTRY KITCHEN BEDROOM LIVING ROOM MECH. LIN. COATS 732 SF (TYPE 2) 1-BEDROOM APARTMENT 313 729 SF (TYPE 2) 1-BEDROOM APARTMENT 314 749 SF (TYPE 2) 1-BEDROOM APARTMENT 312 673 SF (TYPE 2) 1-BEDROOM APARTMENT 310 673 SF (TYPE 2) 1-BEDROOM APARTMENT 308 672 SF (TYPE 2) 1-BEDROOM APARTMENT 306 670 SF (TYPE 2) 1-BEDROOM APARTMENT 304 658 SF (TYPE 2) 1-BEDROOM APARTMENT 303 685 SF (TYPE 4) 1-BEDROOM APARTMENT 302 755 SF (TYPE 3) 1-BEDROOM APARTMENT 301 301.08 301.06 301.04 301.01 301.07 301.02 301.03 302.01 302.02 302.04 302.06 302.07 302.08 302.03 40 SF I.T. CLOSET 316 CUST. 317 314.01 314.03314.02 314.05 314.07 314.06 314.08 314.04 310.07 310.05 310.02 310.03 310.04 310.06 310.08 308.06 308.08 308.04 308.07 308.05 308.03 308.02 306.07 306.02 306.03 306.05 306.04 306.06 306.08304.08 304.06 304.04 304.07 304.02 304.05 304.01 304.03 303.06 303.08 303.04 303.07 303.05 303.02 303.01 303.03 61 SF TRASH / RECYCLE 315 1623 SF CORRIDOR 300 215 SF RECEPTION LOUNGE 300A 315.01 317.01 316.01 279 SF STAIR B B03 234 SF STAIR A A03 A03.01 B03.01 C2 C1 ELEVATOR 305.03 305.02 305.04 305.05A 305.07 305.08 305.06 307.03 307.04 307.08 307.06 307.02 307.07 307.05 309.03 309.02 309.04 309.05 309.07 309.06 309.08 311.03 311.02 311.04 311.05 311.07 311.06 311.08 313.01 313.04 313.05 313.02 313.07 313.08 313.06 313.03 2'-11" 311.01 309.01 307.01 305.01A 306.01 308.01 310.01 1 a501 4A4A4A4A 4A 4A 5 5A 4A 4A 4A 4A4A4A4A 4 5 4A 4A 4A4A 4A 3B 3B 3B 3B 12345677.68910111213141516 A A.5 B B.1 C D E F G H I 2 a501 C7 302.05 301.05 LIN. LIN. 2'-0 1/2" 3'-0"1'-6"3'-0"15'-0 1/2"6'-5"15'-0 3/4"3'-0"1'-6"3'-0" 2'-0 1/2" 1'-11 1/2" 3'-0"1'-6"3'-0"1'-6"3'-0"2'-5"2'-4"3'-5 3/4"3'-0"8'-2 3/4"3'-0"1'-6"3'-0"1'-6"3'-0"2'-7"2'-4"2'-7"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6 "3'-0"1'-6"3'-0"3'-0"3'-0"1'-6"3'-0"1'-6"3'-0"2'-2"2'-4"3'-0"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0" 2'-11 1/4" 2'-0 1/2" 3'-0"1'-6"3'-0"8'-1 3/4"2'-4"1'-6" 3'-0"2'-1 3/4" 2'-0 1/2" 3'-0"1'-6"3'-0"28'-2 1/4"2'-4"6'-0 1/4"3'-0"1'-6"3'-0" 2'-0 1/2" 2'-0 1/2" 3'-0"1'-6"3'-0"6'-0"3'-0"6'-0"3'-0"1'-6"3'-0"1'-6"3'-0"2'-2"2'-4"1'-6"3'-0"5'-8 1/2"6'-4 1/4"13'-0 1/4"3'-0"4'-5 3/4"4'-1 3/4" 2'-0 1/2" 3'-0"1'-6"3'-0"1'-6"3'-0"1'-7"2'-4"3'-7"3'-0" 2'-11 1/2" 3'-0"19'-6"3'-0"1'-6"3'-0"1'-6"3'-0"3'-2"2'-4"2'-0"3'-0"8'-11 1/2"3'-0"3'-8"2'-4"1'-6"3'-0"1'-6"3'-0"1' -6"3'-0"3'-0 1/2"3'-0"1'-6"3'-0"1'-6"3'-0"2'-7"2'-4"2'-7"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0" 1'-7 1/2" 11'-0 3/4"4'-1 3/4"3'-0"3'-4"2'-4"3'-4"3'-0"6'-0"3'-10" 11 1/2" 5'-6 1/4" 4'-8 1/4" 10 13 13 TYP. 14 TYP. 14 TYP.14 TYP.15 TYP.15 TYP. 15 CLEAR 6'-2 1/4" CLEAR 6'-0 1/2" C L E A R 6'-1 3/4" CLEAR 10'-10" C L E A R 6'-1 3/4" 2'-10 1/2" 14'-1 3/4"17'-3 1/2" 9'-8 1/2" 3'-0" 4'-0" 14'-10 3/4"16'-5 1/2" 9'-0" 5'-0" 8'-8" 3'-0" 4'-0" 3'-9 1/2" 9'-0" 4'-0" 14'-8 1/2" 12'-9 1/2" 11'-2 1/2" 12'-7 1/2" 14'-4" 11'-2 1/4" 11'-6" 15'-5 3/4" 13'-5 1/2" 1A 1A 1A 25 673 SF (TYPE 2) 1-BEDROOM APARTMENT 309 3 a501 1 a502 10 10 10 10 10 10 6 4A4A4A 5A 4B 25 25 312.06 312.08 312.04 312.07 312.05 312.02 312.03 312.01 4A INSIDE CLR. 8 1/2" 3B 4 3A 312.09 4'-0"CLR. 6 6 6 STOR. 4'-2 1/2" GENERAL NOTES[FLOOR PLANS] 1. ALL DIMENSION STRINGS FOR WOOD FRAMED ROUGH OPENINGS IN EXTERIOR WALLS ARE TAKEN FROM OUTSIDE FACE OF WOOD STUD AT INSIDE AND OUTSIDE CORNERS, U.N.O.. 2. REFER TO ENLARGED PLANS FOR APARTMENT UNIT DIMENSIONS U.N.O. KEYNOTES[FLOOR PLANS] 1-HOUR FIRE-RATED, SEMI-RECESSED, FIRE EXTINGUISHER CABINET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT EXTINGUISHER TYPE & LOCATION WITH LOCAL FIRE MARSHAL. MOUNT CABINET AT 5-1/2" A.F.F. MEASURED TO BOTTOM OF CABINET. WALL-MOUNTED FIRE EXTINGUISHER BRACKET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT FIRE EXTINGUISHER TYPE WITH THE LOCAL FIRE MARSHAL. MOUNT FIRE EXTINGUISHER AT 48" A.F.F. MEASURED TO TOP OF EXTINGUISHER. PROVIDE 1/2-INCH PLYWOOD AT ELECTRICAL ROOM TO ACCOMMODATE ELECTRICAL EQUIPMENT, THIS WALL. PROVIDE FIRE-RATED ELECTRONIC COMMUNICATION SPEAKER AT RECEPTION AREA. 16-INCH HIGH (ALIGN WITH TOP OF BOTTOM MOST CURTAIN WALL MULLION), 2 1/2-INCH, 20-GAUGE METAL STUD LOW WALL WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUDS OFF FROM CURTAIN WALL 1-INCH AND PROVIDE CLOSED CELL SPRAY FOAM INSUALTION FULL CAVITY OF STUDS. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. COLUMN ENCLOSURE: PROVIDE 2 1/2-INCH, 16-GAUGE METAL STUD FRAMING WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUD FRAMING OFF STRUCTURAL STEEL COLUMN 2INCHES TO CLEAR FIRE-PROOFING. WHERE APPLICABLE, ALIGN GYPSUM BOARD WITH ADJACENT GYPSUM WALL BOARD FOR AN EVEN AND CONTIGUOUS FINISH. PROVIDE & INSTALL UTILITY OR MOP SINK THIS LOCATION, SEE PLUMBING DRAWINGS. PROVIDE & INSTALL WASHER & DRYER EQUIPMENT THIS ROOM, SEE ELECTRICAL DRAWINGS, HVAC DRAWINGS, & SPECIFICATIONS. PROVIDE FOUR (4) BENCHES EQUAL TO WADDELLS METAL BENCH (SIZE: 54"L x 14"D x 17"H). BLACK STEEL FRAME WITH SOLID WOOD CLEAR MAPLE TOP. SKU: W000437032. PROVIDE & INSTALL AUTOMATIC DOOR OPERATOR AND ASSOCIATED POWER, CABLING, ETC., THIS LOCATION, SEE ELECTRICAL DRAWINGS & DOOR HARDWARE. DOOR ACTUATOR SHALL COMPLY WITH ANSI A117.1. PIPE CHASE: PROVIDE & INSTALL 5/8" TYPE-X GYPSUM BOARD SHEATHING OVER STUD FRAMING (METAL STUDS AT GROUND FLOOR, WOOD STUDS FLOORS 2 THROUGH 5) (FLAT STUD) TO ACCOMMODATE PIPING, SEE PLUMBING AND ASSD SYSTEM DRAWINGS. FIRESTOP ALL PENETRATIONS THROUGH FIRE-RATED FLOOR/CEILING ASSEMBLIES. SEMI-RECESSED, WALL-MOUNTED INTERCOM SYSTEM, SEE ELECTRICAL DRAWINGS. MAINTAIN FIRE-RATING OF WALL. FULLY INSULATED AND GASKETED EXTERIOR DOOR, SEE DOOR SCHEDULE. COORDINATE EXACT ELEVATION OF DOOR WITH FLOOR / ROOF ELEVATION, SEE DETAIL. PROVIDE WOOD FRAMED STAIR WITH JOHNSONITE RUBBER STAIR TREADS, INTEGRAL NOSING AND LANDINGS TO MATCH. WOOD FRAMING SHALL HAVE CONTINUOUS VAPOR SEPERATION MEMBRANE FROM CMU SHAFT RAISED PLATFORM AT APARTMENT UNIT MECHANICAL ROOMS FOR VRP UNIT. PROVIDE 3-5/8" 20-GAUGE METAL STUD FRAMING AT GROUND FLOOR AND 2x4 WOOD STUD FRAMING AT FLOORS 2 THROUGH 5. PROVIDE MINERAL WOOD BATT INSULATION IN CAVITY FOR SOUND ISOLATION. RAISED PLATFORM SHALL PROVIDE PROPER ELEVATION TO MECHANICAL UNIT AS TO ALIGN WALL PENETRATION WITH EXTERIOR CLADDING SYSTEM. PROVIDE AND INSTALL CLOSET SHELVING, SEE SPECIFICATIONS. PROVIDE 3 5/8-INCH METAL STUDS WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD CORRIDOR SIDE UP TIGHT TO UNDERSIDE OF DECK. ALIGN GYPSUM WALL BOARD TO ALIGN WITH ADJACENT FURRING AT PILASTER. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. WALL AND WINDOWS ARE RECESSED AT THIS LOCATION, 3-5/8-INCH CLEAR FROM FRAME OF WINDOW TO EXTERIOR CLADDING, SEE DETAILS. RECESSED, WALL-MOUNTED VERTICAL MAILBOXES EQUAL TO 2B GLOBAL, INC.: USPS COLLECTION MODEL. PROVIDE ONE (1)MAILBOX FOR EACH APARTMENT UNIT (SIXTY (60) MAILBOXES TOTAL), TWO (2) ADDITIONAL MAILBOXES (ONE (1) FOR EACH COMMERCIAL TENANT), AND FOUR (4) PARCEL BOXES. FINISH SHALL BE NATURAL ANODIZED WITH ENGRAVED DOOR I.D., COORDINATE LABELING WITH OWNER AND ARCHITECT PRIOR TO ORDERING MAILBOXES. INSTALL ALL FRAMING AND BLOCKING AS REQUIRED TO ACCMMODATE INSTALLATION OF MAILBOXES. INSTALL MAILBOXES TO COMPLY WITH ANSI A117.1 FOR ACCESSIBILITY. PROVIDE AND INSTALL WALL-MOUNTED, HIGH / LOW ELECTRIC WATER COOLERS AND BOTTLE FILLING STATION, SEE PLUMBING DRAWINGS. WATER COOLERS SHALL COMPLY WITH ANSI A117.1. PROVIDE 1-HOUR FIRE-RESISTANCE-RATED PARTITION WALL TIGHT TO UNDERSIDE OF STAIR AT LOWEST LEVEL, TO PREVENT ACCESS TO OR ANY STORAGE BENEATH THE STAIR. PROVIDE AND INSTALL 42-INCH HIGH PARTIAL HEIGHT WALL (WALL TYPE 1) WITH 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. PROVIDE AND INSTALL 32-INCH DEEP HPL WORKSURFACE AT 30-INCH A.F.F.. PROVIDE GUSSET SUPPORT AT 3 POINTS. PROVIDE AND INSTALL HPL CLOTHES FOLDING COUNTERTOP AT 30-INCH A.F.F.. FINISHED FLOORS SHALL SEAMLESSLY ALIGN. COORDINATE EXACT FINISH FLOOR ELEVATION BETWEEN CORRIDOR AND STAIR LANDINGS. 1A 1B 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 # WALL ASSEMBLY, SEE WALL SCHEDULE. CONCRETE WALL, SEE STRUCTURAL DRAWINGS. CMU WALL, SEE STRUCTURAL DRAWINGS. WINDOW / STOREFRONT / CURTAIN WALL, SEE ASSOCIATED SCHEDULES. NEW DOOR, SEE DOOR SCHEDULE. ACCESSIBLE APARTMENT: ACCESSIBLE TO MOBILITY IMPAIRED, SEE ENLARGED PLANS. AUDIBLE / VISUAL APARTMENT: ACCESSIBLE TO HEARING OR VISUALLY IMPAIRED, SEE ELECTRICAL DRAWINGS. LEGEND[REFLECTED CEILING PLANS] 000.01 S10 A/V INTERIOR WALL ASSEMBLY SCHEDULENOTE:PROVIDE CONTINUOUS FIREBLOCKING ABOVE ALL DIMISING WALLS THAT DO NOT EXTEND TO UNDERSIDE OF DECK ABOVE. WALL TYPE 20-GAUGE, 3-5/8" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 4 7/8" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPESAME AS WALL TYPE 1, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 1A 1 WALL TYPE2 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 1/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK WALL TYPE3 2x4 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 FLOOR TO DECK WALL TYPESAME AS WALL TYPE 3, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 3A WALL TYPE4 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 OR GREATER FLOOR TO DECK 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. ROOM SIDE SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 0' - 6 3/4" 0' - 4 3/4" WALL TYPE4AUL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U311 1-HOUR FIRE-RATED 51 OR GREATER FLOOR TO DECK ROOM SIDE 0' - 7 3/4" 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL. 7/16" THICK ORIENTED STRAND BOARD (OSB) SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPE5 8" CMU, SEE STRUCTURAL DRAWINGS. 5/8" TYPE-X GYPSUM BOARD SHEATHING, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U904 3-HR / 2-HR FIRE-RATED 50 FULL HEIGHT OF SHAFT SHAFT SIDE 20-GAUGE, 7/8" METAL FURRING @ 24" O.C., TYPICAL 0' - 9 5/32" WALL TYPESAME AS WALL TYPE 1, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., BEDROOM SIDE. 1B WALL TYPESAME AS WALL TYPE 3, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C. 3B WALL TYPE SAME AS WALL TYPE 5, EXCEPT WITH: 20-GAUGE, 2-1/2" METAL STUD FRAMING @ 24" O.C. (IN LIEU OF 7/8" METAL FURRING) 5A WALL TYPE2A 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 3/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL, CORRIDOR SIDE. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U419 -NON-COMBUSTIBLE 1-HOUR FIRE-RATED 53 FLOOR TO DECK ROOM SIDE WALL / CEILING ASSEMBLY NOTES: 1. ALL PENETRATIONS THRU FIRE RATED ASSEMBLIES (WALL OR CEILING) MUST BE FIRESTOPPED TO THE RATING LEVEL OF THE ASSEMBLY. 2. ALL TRADES TO SUBMIT FIRESTOPPING SCHEDULE FOR ALL PENETRATIONS PRIOR TO COMMENCING WORK PER SPECIFICATIONS 078400 FIRESTOPPING. 3. PROVIDE MARKING AND IDENTIFICATION AT ALL ACCESSIBLE CONCEALED FLOOR, OR FLOOR/CEILINGS TO IDENTIFY FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS OR SMOKE PARTITIONS PER SECTIONS 703.7 OF THE 2015 IBC. 4. ALL BOTTOM PLATES IN CONTACT WITH MASONRY/CONCRETE SHALL BE PRESSURE TREATED WITH SILL SEALER. 5. FOR ALL METAL STUD FRAMING ASSUME 20-GAUGE FOR BIDDING PURPOSES UNLESS OTHERWISE NOTED. ACTUAL GAUGE SHALL BE ENGINEERED BY CONTRACTOR. NOTE:ALL WALL PARTITIONS SHALL HAVE A DOUBLE TOP PLATE, ENTIRE BUILDING, TYPICAL. WALL TYPESAME AS WALL TYPE 4, EXCEPT STAGGER STUDS TO MATCH WIDTH BETWEEN STAIRS AS DELINEATED ON STAIR PLANS. 4B WALL TYPE6UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U417 2-HR FIRE-RATED N/A FULL HEIGHT OF SHAFT 1" THICK TYPE-X GYPSUM BOARD SHAFTLINER 1-1/2" WIDE X 2-1/2" DEEP 'C-T' SHAPED .019" THICK GALVANIZED METAL STUDS SHAFT SIDE TWO (2) LAYERS OF 5/8" TYPE-X GYSUM BOARD SHEATHING 3 3/4" plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. PLAN PROJECT No. DATE ©PLAN ARCHITECTURAL STUDIO, PC SHARS I.D. # 20186081 a103 THIRD FLOOR PLAN 001.16.01.02 11.22.2019 LAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 CONSTRUCTION PERMIT DOCUMENTS SCALE: 1/8" = 1'-0" THIRD FLOOR PLAN 1 N POST BID ADDENDUM #42020.01.31 A4 23'-10 1/8" 16'-1 1/2" 4'-8 7/8" 19'-4 3/8" 4'-4 7/8" 9'-5 5/8" 14'-1 1/4" 10'-1 3/4" 30'-1 5/8" 11'-8 1/8" 22'-3" 7'-8 1/8" 3'-9 1/4" 12'-5 7/8" 10'-0 3/8" 23'-3 3/4" 14'-3 3/4" 6'-1 3/8" 11'-2 1/4" 12'-7 1/2" 23'-3 3/4" 14'-7 3/4" 6'-5 1/2" 11'-6 1/4" 12'-10 3/8" 23'-7 1/2" 15'-4 3/8" 19'-8" 6'-5 1/4" 11'-6 1/4" 13'-5 3/4" 23'-7 1/2" 14'-5 3/8" 6'-5 5/8" 11'-6 1/8" 12'-9 3/8" 8'-11" 23'-7 1/4" 14'-4 3/8" 6'-5 1/8" 11'-6" 12'-9 1/2" 8'-10 7/8" 23'-7 1/2" 14'-3 3/4" 6'-4 7/8" 11'-6 1/8" 8'-10 1/8"" 12'-10 1/4" 23'-7 1/8" 14'-4 3/8" 6'-5" 11'-5 5/8" 12'-9 3/8" 8'-10 1/4" 23'-7 3/4" 14'-3 1/8" 6'-5 1/2" 11'-5 7/8" 12'-9 5/8" 8'-10 5/8" 23'-7" 14'-3 7/8" 6'-5 1/4" 11'-6 1/8" 12'-10" 8'-11 5/8" 23'-7 1/4" 14'-10 7/8" 6'-5 1/8" 11'-6 1/8" 16'-6" 12'-7" 23'-8 3/8" 14'-4" 18'-1 1/2" 11'-6 3/8" 6'-3 7/8" 8'-11 3/8" 12'-10" 11'-5 3/4" 23'-7 1/4" 14'-2 1/8" 5'-8 5/8" 18'-1 5/8" 6'-5 1/4" 17'-3 1/8" 11'-5 7/8" 13'-3 3/4" 5'-7 3/4" 8'-8" 6'-9 3/8" 5'-2 3/8" 17'-9 1/2" 8'-8 5/8" 18'-7 1/2" 5'-8 7/8" 8'-11 1/4" 5'-9" 9'-6 5/8" 5'-8" 18'-1 3/8" 5'-8 3/8" 17'-11 7/8" 5'-8 1/2" 17'-11 5/8" 5'-8 5/8" 17'-11 3/4" 5'-8 5/8" 17'-10 1/2" 5'-8 1/2" 17'-11 1/2" 18'-0" 5'-9 1/4" 5'-7 7/8" 18'-10 7/8" 5'-5 1/8" DN UP DN UP 3 a400 3 a400 2 a400 2 a400 1 a400 1 a400 a606 4A a606 4B C4 C6 C5 KITCHEN LIVING ROOMBEDROOM BATH ENTRY LIN. STORAGE COATSCLOSET MECH. KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY BEDROOM CLOSET LIN. COATS MECH. LIVING ROOM KITCHEN ENTRY STOR. BATH LIVING ROOM BEDROOM MECH. KITCHEN STOR. ENTRY BATH COATS CLOSET KITCHEN COATS STOR. CLOSET MECH. LIVING ROOM BEDROOM BATH ENTRY STOR. BATH CLOSET ENTRY KITCHEN BEDROOM LIVING ROOM MECH. LIN. COATS 716 SF (TYPE 2) 1-BEDROOM APARTMENT 405 673 SF (TYPE 2) 1-BEDROOM APARTMENT 407 Not Enclosed (TYPE 2) 1-BEDROOM APARTMENT 409 673 SF (TYPE 2) 1-BEDROOM APARTMENT 411 732 SF (TYPE 2) 1-BEDROOM APARTMENT 413 729 SF (TYPE 2) 1-BEDROOM APARTMENT 414 749 SF (TYPE 2) 1-BEDROOM APARTMENT 412 673 SF (TYPE 2) 1-BEDROOM APARTMENT 410 673 SF (TYPE 2) 1-BEDROOM APARTMENT 408 672 SF (TYPE 2) 1-BEDROOM APARTMENT 406 670 SF (TYPE 2) 1-BEDROOM APARTMENT 404 402.01 402.02 402.04 402.06 402.07 402.08 402.03 401.01 401.03 401.04 401.08 401.06 401.07 401.02 658 SF (TYPE 2) 1-BEDROOM APARTMENT 403 685 SF (TYPE 4) 1-BEDROOM APARTMENT 402 755 SF (TYPE 3) 1-BEDROOM APARTMENT 401 1623 SF CORRIDOR 400 61 SF TRASH / RECYCLE 415 40 SF I.T. CLOSET 416 CUST. 417 403.01 403.03403.02 403.07 403.05 403.06 403.08 403.04 404.01 404.03 404.02 404.07 404.08 404.06 404.04 404.05 406.03406.02 406.07 406.05 406.06 406.08 406.04 408.06 408.08 408.04 408.07 408.05 408.03408.02 410.02 410.07 410.05 410.06 410.04 410.08 410.03 414.06 414.08 414.04 414.07 414.05 414.01 414.03414.02 413.01 413.03 413.02 413.05 413.07 413.04 413.06 413.08 411.06 411.04 411.03 411.05 411.07 411.02 409.03 409.02 409.05 409.04 409.08 409.06 409.07 407.03 407.02 407.05 407.04 407.06 407.08 407.07 405.07 405.02 405.01 405.03 405.05 405.04 405.06 405.08 411.08 415.01 B04.01 416.01 417.01 STAIR B B04 215 SF RECEPTION LOUNGE 400A 234 SF STAIR A A04 C2 C1 ELEVATOR A04.01 411.01 409.01 407.01 406.01 408.01 410.01 1 a501 4A4A4A4A 4A 4A 5 5A 4A 4A 4A 4A4A4A4A 4 5 4A 4A 4A4A 4A 3B 3B 3B 3B 12345677.68910111213141516 A A.5 B B.1 C D E F G H I A/V 2 a501 C7 402.05 LIN. LIN. 401.05 2'-0 1/2" 3'-0"1'-6"3'-0"28'-2 1/4"2'-4"6'-0 1/4"3'-0"1'-6"3'-0" 2'-0 1/2" 2'-0 1/2" 3'-0"1'-6"3'-0"6'-0"3'-0"6'-0"3'-0"1'-6"3'-0"1'-6 "3'-0"2'-2"2'-4"1'-6"3'-0"5'-8 1/2"6'-4 1/4"13'-0 1/4"3'-0"4'-5 3/4"4'-1 3/4" 2'-0 1/2" 3'-0"1'-6"3'-0"1'-6"3'-0"1'-7"2'-4"3'-7"3'-0" 2'-11 1/2" 3'-0"5'-10 1/4"3'-4"10'-3 3/4"3'-0"1'-6"3'-0"1'-6"3'-0 "3'-2"2'-4"2'-0"3'-0"8'-11 1/2"3'-0"3'-8"2'-4"1'-6"3'-0"1'-6"3'-0"1'-6"3'-0"3'-0 1/2"3'-0"1'-6"3'-0"1'-6"3'-0"2'-7"2'-4"2'-7"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0" 1'-7 1/2" 11'-0 3/4"4'-1 3/4"3'-0"3'-4"2'-4"3'-4"3'-0"6'-0"3'-10" 2'-0 1/2" 3'-0"1'-6"3'-0"15'-0 1/2"6'-5"15'-0 3/4"3'-0"1'-6"3'-0" 2'-0 1/2" 1'-11 1/2" 3'-0"1'-6"3'-0"1'-6"3'-0"2'-5"2'-4"3'-5 3/4"3'-0"8'-2 3/4"3'-0"1'-6"3'-0"1'-6"3'-0"2'-7"2'-4"2'-7"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0"3'-0"3'-0"1'-6"2'-2"2'-4"3'-0"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0" 1'-6"3'-0" 2'-8 1/2" 2'-0 1/2" 3'-0"1'-6"3'-0"8'-1 3/4"2'-4"1'-6" 3'-0"2'-8" 3'-0"1'-6"3'-0" 11 1/2" 5'-6 1/4" 4'-8 1/4" 10 13 13 TYP. 14 TYP. 14 TYP.14 TYP.15 TYP.15 TYP. 15 CLEAR 6'-2 1/4" CLEAR 6'-0 1/2" C L E A R 6'-1 3/4" CLEAR 10'-10" C L E A R 6'-1 3/4" 2'-10 1/2" 14'-1 3/4"17'-3 1/2" 9'-8 1/2" 3'-0" 4'-0" 14'-10 3/4"16'-5 1/2" 9'-0" 5'-0" 8'-8" 3'-0" 4'-0" 3'-9 1/2" 9'-0" 4'-0" 1A 1A 1A 25 3 a501 1 a502 10 10 10 10 10 10 6 4A 4A4A4A 5A 4B 25 25 412.03412.02 412.07 412.05 412.06 412.08 412.04 412.01 3A 4 412.09 4'-0"CLR. 6 6 6 3B STOR. 4'-2 1/2" INTERIOR WALL ASSEMBLY SCHEDULENOTE:PROVIDE CONTINUOUS FIREBLOCKING ABOVE ALL DIMISING WALLS THAT DO NOT EXTEND TO UNDERSIDE OF DECK ABOVE. WALL TYPE 20-GAUGE, 3-5/8" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 4 7/8" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPESAME AS WALL TYPE 1, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 1A 1 WALL TYPE2 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 1/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK WALL TYPE3 2x4 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 FLOOR TO DECK WALL TYPESAME AS WALL TYPE 3, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 3A WALL TYPE4 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 OR GREATER FLOOR TO DECK 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. ROOM SIDE SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 0' - 6 3/4" 0' - 4 3/4" WALL TYPE4AUL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U311 1-HOUR FIRE-RATED 51 OR GREATER FLOOR TO DECK ROOM SIDE 0' - 7 3/4" 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL. 7/16" THICK ORIENTED STRAND BOARD (OSB) SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPE5 8" CMU, SEE STRUCTURAL DRAWINGS. 5/8" TYPE-X GYPSUM BOARD SHEATHING, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U904 3-HR / 2-HR FIRE-RATED 50 FULL HEIGHT OF SHAFT SHAFT SIDE 20-GAUGE, 7/8" METAL FURRING @ 24" O.C., TYPICAL 0' - 9 5/32" WALL TYPESAME AS WALL TYPE 1, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., BEDROOM SIDE. 1B WALL TYPESAME AS WALL TYPE 3, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C. 3B WALL TYPE SAME AS WALL TYPE 5, EXCEPT WITH: 20-GAUGE, 2-1/2" METAL STUD FRAMING @ 24" O.C. (IN LIEU OF 7/8" METAL FURRING) 5A WALL TYPE2A 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 3/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL, CORRIDOR SIDE. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U419 -NON-COMBUSTIBLE 1-HOUR FIRE-RATED 53 FLOOR TO DECK ROOM SIDE WALL / CEILING ASSEMBLY NOTES: 1. ALL PENETRATIONS THRU FIRE RATED ASSEMBLIES (WALL OR CEILING) MUST BE FIRESTOPPED TO THE RATING LEVEL OF THE ASSEMBLY. 2. ALL TRADES TO SUBMIT FIRESTOPPING SCHEDULE FOR ALL PENETRATIONS PRIOR TO COMMENCING WORK PER SPECIFICATIONS 078400 FIRESTOPPING. 3. PROVIDE MARKING AND IDENTIFICATION AT ALL ACCESSIBLE CONCEALED FLOOR, OR FLOOR/CEILINGS TO IDENTIFY FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS OR SMOKE PARTITIONS PER SECTIONS 703.7 OF THE 2015 IBC. 4. ALL BOTTOM PLATES IN CONTACT WITH MASONRY/CONCRETE SHALL BE PRESSURE TREATED WITH SILL SEALER. 5. FOR ALL METAL STUD FRAMING ASSUME 20-GAUGE FOR BIDDING PURPOSES UNLESS OTHERWISE NOTED. ACTUAL GAUGE SHALL BE ENGINEERED BY CONTRACTOR. NOTE:ALL WALL PARTITIONS SHALL HAVE A DOUBLE TOP PLATE, ENTIRE BUILDING, TYPICAL. WALL TYPESAME AS WALL TYPE 4, EXCEPT STAGGER STUDS TO MATCH WIDTH BETWEEN STAIRS AS DELINEATED ON STAIR PLANS. 4B WALL TYPE6UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U417 2-HR FIRE-RATED N/A FULL HEIGHT OF SHAFT 1" THICK TYPE-X GYPSUM BOARD SHAFTLINER 1-1/2" WIDE X 2-1/2" DEEP 'C-T' SHAPED .019" THICK GALVANIZED METAL STUDS SHAFT SIDE TWO (2) LAYERS OF 5/8" TYPE-X GYSUM BOARD SHEATHING 3 3/4" GENERAL NOTES[FLOOR PLANS] 1. ALL DIMENSION STRINGS FOR WOOD FRAMED ROUGH OPENINGS IN EXTERIOR WALLS ARE TAKEN FROM OUTSIDE FACE OF WOOD STUD AT INSIDE AND OUTSIDE CORNERS, U.N.O.. 2. REFER TO ENLARGED PLANS FOR APARTMENT UNIT DIMENSIONS U.N.O. KEYNOTES[FLOOR PLANS] 1-HOUR FIRE-RATED, SEMI-RECESSED, FIRE EXTINGUISHER CABINET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT EXTINGUISHER TYPE & LOCATION WITH LOCAL FIRE MARSHAL. MOUNT CABINET AT 5-1/2" A.F.F. MEASURED TO BOTTOM OF CABINET. WALL-MOUNTED FIRE EXTINGUISHER BRACKET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT FIRE EXTINGUISHER TYPE WITH THE LOCAL FIRE MARSHAL. MOUNT FIRE EXTINGUISHER AT 48" A.F.F. MEASURED TO TOP OF EXTINGUISHER. PROVIDE 1/2-INCH PLYWOOD AT ELECTRICAL ROOM TO ACCOMMODATE ELECTRICAL EQUIPMENT, THIS WALL. PROVIDE FIRE-RATED ELECTRONIC COMMUNICATION SPEAKER AT RECEPTION AREA. 16-INCH HIGH (ALIGN WITH TOP OF BOTTOM MOST CURTAIN WALL MULLION), 2 1/2-INCH, 20-GAUGE METAL STUD LOW WALL WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUDS OFF FROM CURTAIN WALL 1-INCH AND PROVIDE CLOSED CELL SPRAY FOAM INSUALTION FULL CAVITY OF STUDS. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. COLUMN ENCLOSURE: PROVIDE 2 1/2-INCH, 16-GAUGE METAL STUD FRAMING WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUD FRAMING OFF STRUCTURAL STEEL COLUMN 2INCHES TO CLEAR FIRE-PROOFING. WHERE APPLICABLE, ALIGN GYPSUM BOARD WITH ADJACENT GYPSUM WALL BOARD FOR AN EVEN AND CONTIGUOUS FINISH. PROVIDE & INSTALL UTILITY OR MOP SINK THIS LOCATION, SEE PLUMBING DRAWINGS. PROVIDE & INSTALL WASHER & DRYER EQUIPMENT THIS ROOM, SEE ELECTRICAL DRAWINGS, HVAC DRAWINGS, & SPECIFICATIONS. PROVIDE FOUR (4) BENCHES EQUAL TO WADDELLS METAL BENCH (SIZE: 54"L x 14"D x 17"H). BLACK STEEL FRAME WITH SOLID WOOD CLEAR MAPLE TOP. SKU: W000437032. PROVIDE & INSTALL AUTOMATIC DOOR OPERATOR AND ASSOCIATED POWER, CABLING, ETC., THIS LOCATION, SEE ELECTRICAL DRAWINGS & DOOR HARDWARE. DOOR ACTUATOR SHALL COMPLY WITH ANSI A117.1. PIPE CHASE: PROVIDE & INSTALL 5/8" TYPE-X GYPSUM BOARD SHEATHING OVER STUD FRAMING (METAL STUDS AT GROUND FLOOR, WOOD STUDS FLOORS 2 THROUGH 5) (FLAT STUD) TO ACCOMMODATE PIPING, SEE PLUMBING AND ASSD SYSTEM DRAWINGS. FIRESTOP ALL PENETRATIONS THROUGH FIRE-RATED FLOOR/CEILING ASSEMBLIES. SEMI-RECESSED, WALL-MOUNTED INTERCOM SYSTEM, SEE ELECTRICAL DRAWINGS. MAINTAIN FIRE-RATING OF WALL. FULLY INSULATED AND GASKETED EXTERIOR DOOR, SEE DOOR SCHEDULE. COORDINATE EXACT ELEVATION OF DOOR WITH FLOOR / ROOF ELEVATION, SEE DETAIL. PROVIDE WOOD FRAMED STAIR WITH JOHNSONITE RUBBER STAIR TREADS, INTEGRAL NOSING AND LANDINGS TO MATCH. WOOD FRAMING SHALL HAVE CONTINUOUS VAPOR SEPERATION MEMBRANE FROM CMU SHAFT RAISED PLATFORM AT APARTMENT UNIT MECHANICAL ROOMS FOR VRP UNIT. PROVIDE 3-5/8" 20-GAUGE METAL STUD FRAMING AT GROUND FLOOR AND 2x4 WOOD STUD FRAMING AT FLOORS 2 THROUGH 5. PROVIDE MINERAL WOOD BATT INSULATION IN CAVITY FOR SOUND ISOLATION. RAISED PLATFORM SHALL PROVIDE PROPER ELEVATION TO MECHANICAL UNIT AS TO ALIGN WALL PENETRATION WITH EXTERIOR CLADDING SYSTEM. PROVIDE AND INSTALL CLOSET SHELVING, SEE SPECIFICATIONS. PROVIDE 3 5/8-INCH METAL STUDS WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD CORRIDOR SIDE UP TIGHT TO UNDERSIDE OF DECK. ALIGN GYPSUM WALL BOARD TO ALIGN WITH ADJACENT FURRING AT PILASTER. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. WALL AND WINDOWS ARE RECESSED AT THIS LOCATION, 3-5/8-INCH CLEAR FROM FRAME OF WINDOW TO EXTERIOR CLADDING, SEE DETAILS. RECESSED, WALL-MOUNTED VERTICAL MAILBOXES EQUAL TO 2B GLOBAL, INC.: USPS COLLECTION MODEL. PROVIDE ONE (1)MAILBOX FOR EACH APARTMENT UNIT (SIXTY (60) MAILBOXES TOTAL), TWO (2) ADDITIONAL MAILBOXES (ONE (1) FOR EACH COMMERCIAL TENANT), AND FOUR (4) PARCEL BOXES. FINISH SHALL BE NATURAL ANODIZED WITH ENGRAVED DOOR I.D., COORDINATE LABELING WITH OWNER AND ARCHITECT PRIOR TO ORDERING MAILBOXES. INSTALL ALL FRAMING AND BLOCKING AS REQUIRED TO ACCMMODATE INSTALLATION OF MAILBOXES. INSTALL MAILBOXES TO COMPLY WITH ANSI A117.1 FOR ACCESSIBILITY. PROVIDE AND INSTALL WALL-MOUNTED, HIGH / LOW ELECTRIC WATER COOLERS AND BOTTLE FILLING STATION, SEE PLUMBING DRAWINGS. WATER COOLERS SHALL COMPLY WITH ANSI A117.1. PROVIDE 1-HOUR FIRE-RESISTANCE-RATED PARTITION WALL TIGHT TO UNDERSIDE OF STAIR AT LOWEST LEVEL, TO PREVENT ACCESS TO OR ANY STORAGE BENEATH THE STAIR. PROVIDE AND INSTALL 42-INCH HIGH PARTIAL HEIGHT WALL (WALL TYPE 1) WITH 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. PROVIDE AND INSTALL 32-INCH DEEP HPL WORKSURFACE AT 30-INCH A.F.F.. PROVIDE GUSSET SUPPORT AT 3 POINTS. PROVIDE AND INSTALL HPL CLOTHES FOLDING COUNTERTOP AT 30-INCH A.F.F.. FINISHED FLOORS SHALL SEAMLESSLY ALIGN. COORDINATE EXACT FINISH FLOOR ELEVATION BETWEEN CORRIDOR AND STAIR LANDINGS. 1A 1B 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 # WALL ASSEMBLY, SEE WALL SCHEDULE. CONCRETE WALL, SEE STRUCTURAL DRAWINGS. CMU WALL, SEE STRUCTURAL DRAWINGS. WINDOW / STOREFRONT / CURTAIN WALL, SEE ASSOCIATED SCHEDULES. NEW DOOR, SEE DOOR SCHEDULE. ACCESSIBLE APARTMENT: ACCESSIBLE TO MOBILITY IMPAIRED, SEE ENLARGED PLANS. AUDIBLE / VISUAL APARTMENT: ACCESSIBLE TO HEARING OR VISUALLY IMPAIRED, SEE ELECTRICAL DRAWINGS. LEGEND[REFLECTED CEILING PLANS] 000.01 S10 A/V plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. PLAN PROJECT No. DATE ©PLAN ARCHITECTURAL STUDIO, PC SHARS I.D. # 20186081 a104 FOURTH FLOOR PLAN 001.16.01.02 11.22.2019 LAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 CONSTRUCTION PERMIT DOCUMENTS SCALE: 1/8" = 1'-0" FOURTH FLOOR PLAN 1 N POST BID ADDENDUM #42020.01.31 A4 23'-10 3/8" 16'-1 3/8" 4'-9 1/8 19'-4 5/8" 4'-4 7/8" 9'-6" 14'-1 1/4" 10'-2" 30'-2 1/4" 11'-8 1/4" 22'-3 3/8" 7'-9" 3'-9 7/8" 12'-6 1/8" 9'-11 3/4" 23'-3 5/8" 14'-4 1/4" 6'-1 3/8" 11'-2 3/8" 12'-7 7/8" 23'-5 1/8" 14'-8" 6'-6 5/8" 11'-7 1/4" 12'-10 1/8" 23'-7 7/8" 15'-4 3/8" 19'-9" 6'-4 7/8" 11'-6 1/8" 13'-5 1/8" 23'-7 3/4" 14'-6" 6'-5 1/4" 11'-6 1/8" 12'-9 1/2" 8'-10 7/8" 23'-7 1/2" 14'-3 3/8" 6'-5" 11'-6" 12'-10 3/8" 8'-11 3/8" 23'-8" 14'-4" 6'-5" 11'-6" 8'-10 7/8"" 12'-9 7/8" 23'-6 3/4" 14'-4 7/8" 6'-5" 11'-5 3/4" 12'-10 1/8" 8'-11 1/8" 23'-8" 14'-3 5/8" 6'-6" 11'-7" 12'-9 3/8" 8'-10 3/8" 23'-6 3/4" 14'-4 1/4" 6'-5 1/8" 11'-6 1/8" 12'-9 3/4" 8'-11 1/8" 23'-7 1/2" 14'-11 1/2" 6'-4 1/2" 11'-5 7/8" 16'-6" 12'-7 1/2" 23'-8 5/8" 13'-6 1/2" 18'-1 3/4" 11'-7" 6'-5 7/8" 8'-11" 12'-10 1/8" 11'-7" 23'-7 3/8" 14'-3 1/4" 5'-7 5/8" 18'-2 1/4" 6'-6" 17'-2" 11'-6 3/4" 13'-2 7/8" 5'-7 5/8" 8'-8 1/4" 13'-2 1/2" 6'-7" 5'-1 7/8" 17'-9 7/8" 8'-8 3/4" 18'-8 1/4" 5'-8 3/8" 8'-11 3/4" 5'-8 1/8" 9'-5 7/8" 5'-8 5/8" 18'-1 5/8" 5'-8 1/2" 18'-0" 5'-8 3/8" 17'-11 1/2" 5'-8 1/8" 17'-11 1/4" 5'-8 3/8" 17'-10 7/8" 5'-8 1/4" 18'-0 1/4" 18'-0" 5'-8 3/8" 5'-7 7/8" 18'-11 3/4" DN UP DN 3 a400 3 a400 2 a400 2 a400 1 a400 1 a400 A/V a606 5A a606 5B C4 C6 C5 KITCHEN LIVING ROOMBEDROOM BATH ENTRY LIN. STORAGE COATSCLOSET MECH. KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN.CLOSET COATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY KITCHEN STOR. LIN. CLOSETCOATS BATH LIVING ROOM MECH. BEDROOM ENTRY BEDROOM CLOSET LIN. COATS MECH. LIVING ROOM KITCHEN ENTRY STOR. BATH LIVING ROOM BEDROOM MECH. KITCHEN STOR. ENTRY BATH COATS CLOSET KITCHEN COATS STOR. CLOSET MECH. LIVING ROOM BEDROOM BATH ENTRY STOR. BATH CLOSET ENTRY KITCHEN BEDROOM LIVING ROOM MECH. LIN. COATS 279 SF STAIR B B05 40 SF I.T. CLOSET 516 CUST. 517 501.08 501.06 501.04 501.07 501.03 501.01 501.02 502.06 502.08 502.04 502.07 502.02502.01 502.03 755 SF (TYPE 3) 1-BEDROOM APARTMENT 501 685 SF (TYPE 4) 1-BEDROOM APARTMENT 502 658 SF (TYPE 2) 1-BEDROOM APARTMENT 503 C2 C1 670 SF (TYPE 2) 1-BEDROOM APARTMENT 504 716 SF (TYPE 1) 1-BEDROOM APARTMENT 505 672 SF (TYPE 2) 1-BEDROOM APARTMENT 506 673 SF (TYPE 2) 1-BEDROOM APARTMENT 507 673 SF (TYPE 2) 1-BEDROOM APARTMENT 508 673 SF (TYPE 2) 1-BEDROOM APARTMENT 510 673 SF (TYPE 2) 1-BEDROOM APARTMENT 511 749 SF (TYPE 2) 1-BEDROOM APARTMENT 512 732 SF (TYPE 2) 1-BEDROOM APARTMENT 513 729 SF (TYPE 2) 1-BEDROOM APARTMENT 514 61 SF TRASH / RECYCLE 515 1623 SF CORRIDOR 500 215 SF RECEPTION LOUNGE 500A 234 SF STAIR A A05 ELEVATOR 503.04 503.06 503.08 503.01 503.02 503.05 503.07 503.03 504.04 504.06 504.08 504.07 504.02 504.05 504.01 504.03 506.03506.02 506.05 506.07 506.08 506.06 506.04 508.04 508.06 508.08 508.03508.02 508.05 508.07 510.02 510.05 510.07 510.03 510.04 510.08 510.06 B05.01 516.01 517.01 515.01 514.01 514.03514.02 514.05 514.07 514.04 514.08 514.06 513.04 513.06 513.08 513.07 513.05 513.02 513.01 513.03 511.03 511.02 511.05 511.07 511.06 511.08 511.04509.04 509.07 509.08 509.02 509.05 509.06 509.03 507.03 507.02 507.05 507.07 507.04 507.06 507.08 A05.01 505.06 505.08 505.04 505.01 505.03 505.02 505.05 505.07 511.01 509.01 507.01 510.01 508.01 506.01 1 a501 4A4A4A4A 4A 4A 5 5A 4A 4A 4A 4A4A4A4A 4 5 4A 4A 4A4A 4A 3B 3B 3B 3B 12345677.68910111213141516 A A.5 B B.1 C D E F G H I 673 SF (TYPE 2) 1-BEDROOM APARTMENT 509 2 a501 C7 LIN. LIN. 502.05 501.05 2'-0 1/2" 3'-0"1'-6"3'-0"28'-2 1/4"2'-4"6'-0 1/4"3'-0"1'-6"3'-0" 2'-0 1/2" 2'-0 1/2" 3'-0"1'-6"3'-0"6'-0"3'-0"6'-0"3'-0"1'-6"3'-0"1'-6"3'-0"2'-2"2'-4"1'-6"3'-0"5'-8 1/2"6'-4 1/4"13'-0 1/4"3'-0"4'-5 3/4"4'-1 3/4" 2'-0 1/2" 3'-0"1'-6"3'-0"1'-6"3'-0"1'-7"2'-4"3'-7"3'-0" 2'-11 1/2" 3'-0"5'-10 1/4"3'-4"10'-3 3/4"3'-0"1'-6"3'-0"1'-6"3'-0"3'-2"2'-4"2'-0"3'-0"8'-11 1/2"3'-0"3'-8"2'-4"1'-6"3'-0"1'-6"3'-0"1'-6"3'-0"3 '-0 1/2"3'-0"1'-6"3'-0"1'-6"3'-0"2'-7"2'-4"2'-7"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0" 1'-7 1/2" 11'-0 3/4"4'-1 3/4"3'-0"3'-4"2'-4"3'-4"3'-0"6'-0"3'-10" 2'-0 1/2" 3'-0"1'-6"3'-0"15'-0 1/2"6'-5"15'-0 3/4"3'-0"1'-6"3'-0" 2'-0 1/2" 1'-11 1/2" 3'-0"1'-6"3'-0"1'-6"3'-0"2'-5"2'-4"3'-5 3/4"3'-0"8'-2 3/4"3'-0"1'-6"3'-0"1'-6"3'-0"2'-7"2'-4"2'-7"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0"3'-0"3'-0"1'-6"3'-0"1'-6"3'-0"2'-2"2'-4"3'-0"3'-0"8'-11 1/2"3'-0"3'-0"2'-4"2'-2"3'-0"1'-6"3'-0"1'-6"3'-0" 2'-11 1/4" 2'-0 1/2" 3'-0"1'-6"3'-0"8'-1 3/4"2'-4"1'-6" 3'-0"2'-1 3/4" 11 1/2" 5'-6 1/4" 4'-8 1/4" 10 13 13 TYP. 14 TYP. 14 TYP.14 TYP.15 TYP.15 TYP. 15 CLEAR 6'-2 1/4" CLEAR 6'-0 1/2" C L E A R 6'-1 3/4" CLEAR 10'-10" C L E A R 6'-1 3/4" 2'-10 1/2" 2'-10 1/2" 14'-1 3/4"17'-3 1/2" 9'-8 1/2" 3'-0" 4'-0" 14'-10 3/4"16'-5 1/2" 9'-0" 5'-0" 8'-8" 3'-0" 4'-0" 3'-9 1/2" 9'-0" 4'-0" 1A 1A 1A 25 3 a501 1 a502 10 10 10 10 10 10 6 3 a502 4A4A4A 5A 4B 25 25 512.06 512.08 512.04 512.03512.02 512.05 512.07 512.01 4A 3A 4 3B 512.09 4'-0"CLR. 6 6 6 STOR. 4'-2 1/2" INTERIOR WALL ASSEMBLY SCHEDULENOTE:PROVIDE CONTINUOUS FIREBLOCKING ABOVE ALL DIMISING WALLS THAT DO NOT EXTEND TO UNDERSIDE OF DECK ABOVE. WALL TYPE 20-GAUGE, 3-5/8" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 4 7/8" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPESAME AS WALL TYPE 1, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 1A 1 WALL TYPE2 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 1/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK FIRE-RATING: STC RATING: EXTENT: NON-COMBUSTIBLE 40 FLOOR TO DECK WALL TYPE3 2x4 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 FLOOR TO DECK WALL TYPESAME AS WALL TYPE 3, EXCEPT: GYPSUM BOARD SHEATHING, ROOM SIDE. 3A WALL TYPE4 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U305 1-HOUR FIRE-RATED 36 OR GREATER FLOOR TO DECK 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. ROOM SIDE SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 0' - 6 3/4" 0' - 4 3/4" WALL TYPE4AUL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U311 1-HOUR FIRE-RATED 51 OR GREATER FLOOR TO DECK ROOM SIDE 0' - 7 3/4" 2x6 (NOMINAL) SOLID WOOD STUD FRAMING @ 16" O.C., TYPICAL. 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL. 7/16" THICK ORIENTED STRAND BOARD (OSB) SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. WALL TYPE5 8" CMU, SEE STRUCTURAL DRAWINGS. 5/8" TYPE-X GYPSUM BOARD SHEATHING, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U904 3-HR / 2-HR FIRE-RATED 50 FULL HEIGHT OF SHAFT SHAFT SIDE 20-GAUGE, 7/8" METAL FURRING @ 24" O.C., TYPICAL 0' - 9 5/32" WALL TYPESAME AS WALL TYPE 1, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., BEDROOM SIDE. 1B WALL TYPESAME AS WALL TYPE 3, EXCEPT WITH: 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C. 3B WALL TYPE SAME AS WALL TYPE 5, EXCEPT WITH: 20-GAUGE, 2-1/2" METAL STUD FRAMING @ 24" O.C. (IN LIEU OF 7/8" METAL FURRING) 5A WALL TYPE2A 20-GAUGE, 6" METAL STUD FRAMING @ 16" O.C., TYPICAL. 0' - 7 3/4" 5/8" TYPE-X GYPSUM BOARD SHEATHING, BOTH SIDES, PREP., PRIME AND PAINT, TYPICAL, SEE FINISH SCHEDULE & SPECIFICATIONS. SOUND-ABSORBENT, BATT INSULATION, FILL ENTIRE CAVITY, SEE SPECIFICATIONS. 20-GAUGE, 1/2" RC-1 RESILIENT CHANNELS AT 24" O.C., TYPICAL, CORRIDOR SIDE. UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U419 -NON-COMBUSTIBLE 1-HOUR FIRE-RATED 53 FLOOR TO DECK ROOM SIDE WALL / CEILING ASSEMBLY NOTES: 1. ALL PENETRATIONS THRU FIRE RATED ASSEMBLIES (WALL OR CEILING) MUST BE FIRESTOPPED TO THE RATING LEVEL OF THE ASSEMBLY. 2. ALL TRADES TO SUBMIT FIRESTOPPING SCHEDULE FOR ALL PENETRATIONS PRIOR TO COMMENCING WORK PER SPECIFICATIONS 078400 FIRESTOPPING. 3. PROVIDE MARKING AND IDENTIFICATION AT ALL ACCESSIBLE CONCEALED FLOOR, OR FLOOR/CEILINGS TO IDENTIFY FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS OR SMOKE PARTITIONS PER SECTIONS 703.7 OF THE 2015 IBC. 4. ALL BOTTOM PLATES IN CONTACT WITH MASONRY/CONCRETE SHALL BE PRESSURE TREATED WITH SILL SEALER. 5. FOR ALL METAL STUD FRAMING ASSUME 20-GAUGE FOR BIDDING PURPOSES UNLESS OTHERWISE NOTED. ACTUAL GAUGE SHALL BE ENGINEERED BY CONTRACTOR. NOTE:ALL WALL PARTITIONS SHALL HAVE A DOUBLE TOP PLATE, ENTIRE BUILDING, TYPICAL. WALL TYPESAME AS WALL TYPE 4, EXCEPT STAGGER STUDS TO MATCH WIDTH BETWEEN STAIRS AS DELINEATED ON STAIR PLANS. 4B WALL TYPE6UL ASSEMBLY: FIRE-RATING: STC RATING: EXTENT: UL U417 2-HR FIRE-RATED N/A FULL HEIGHT OF SHAFT 1" THICK TYPE-X GYPSUM BOARD SHAFTLINER 1-1/2" WIDE X 2-1/2" DEEP 'C-T' SHAPED .019" THICK GALVANIZED METAL STUDS SHAFT SIDE TWO (2) LAYERS OF 5/8" TYPE-X GYSUM BOARD SHEATHING 3 3/4" GENERAL NOTES[FLOOR PLANS] 1. ALL DIMENSION STRINGS FOR WOOD FRAMED ROUGH OPENINGS IN EXTERIOR WALLS ARE TAKEN FROM OUTSIDE FACE OF WOOD STUD AT INSIDE AND OUTSIDE CORNERS, U.N.O.. 2. REFER TO ENLARGED PLANS FOR APARTMENT UNIT DIMENSIONS U.N.O. KEYNOTES[FLOOR PLANS] 1-HOUR FIRE-RATED, SEMI-RECESSED, FIRE EXTINGUISHER CABINET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT EXTINGUISHER TYPE & LOCATION WITH LOCAL FIRE MARSHAL. MOUNT CABINET AT 5-1/2" A.F.F. MEASURED TO BOTTOM OF CABINET. WALL-MOUNTED FIRE EXTINGUISHER BRACKET AND ASSOCIATED FIRE EXTINGUISHER, SEE SPECIFICATIONS. COORDINATE EXACT FIRE EXTINGUISHER TYPE WITH THE LOCAL FIRE MARSHAL. MOUNT FIRE EXTINGUISHER AT 48" A.F.F. MEASURED TO TOP OF EXTINGUISHER. PROVIDE 1/2-INCH PLYWOOD AT ELECTRICAL ROOM TO ACCOMMODATE ELECTRICAL EQUIPMENT, THIS WALL. PROVIDE FIRE-RATED ELECTRONIC COMMUNICATION SPEAKER AT RECEPTION AREA. 16-INCH HIGH (ALIGN WITH TOP OF BOTTOM MOST CURTAIN WALL MULLION), 2 1/2-INCH, 20-GAUGE METAL STUD LOW WALL WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUDS OFF FROM CURTAIN WALL 1-INCH AND PROVIDE CLOSED CELL SPRAY FOAM INSUALTION FULL CAVITY OF STUDS. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. COLUMN ENCLOSURE: PROVIDE 2 1/2-INCH, 16-GAUGE METAL STUD FRAMING WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD ROOM SIDE. STAND METAL STUD FRAMING OFF STRUCTURAL STEEL COLUMN 2INCHES TO CLEAR FIRE-PROOFING. WHERE APPLICABLE, ALIGN GYPSUM BOARD WITH ADJACENT GYPSUM WALL BOARD FOR AN EVEN AND CONTIGUOUS FINISH. PROVIDE & INSTALL UTILITY OR MOP SINK THIS LOCATION, SEE PLUMBING DRAWINGS. PROVIDE & INSTALL WASHER & DRYER EQUIPMENT THIS ROOM, SEE ELECTRICAL DRAWINGS, HVAC DRAWINGS, & SPECIFICATIONS. PROVIDE FOUR (4) BENCHES EQUAL TO WADDELLS METAL BENCH (SIZE: 54"L x 14"D x 17"H). BLACK STEEL FRAME WITH SOLID WOOD CLEAR MAPLE TOP. SKU: W000437032. PROVIDE & INSTALL AUTOMATIC DOOR OPERATOR AND ASSOCIATED POWER, CABLING, ETC., THIS LOCATION, SEE ELECTRICAL DRAWINGS & DOOR HARDWARE. DOOR ACTUATOR SHALL COMPLY WITH ANSI A117.1. PIPE CHASE: PROVIDE & INSTALL 5/8" TYPE-X GYPSUM BOARD SHEATHING OVER STUD FRAMING (METAL STUDS AT GROUND FLOOR, WOOD STUDS FLOORS 2 THROUGH 5) (FLAT STUD) TO ACCOMMODATE PIPING, SEE PLUMBING AND ASSD SYSTEM DRAWINGS. FIRESTOP ALL PENETRATIONS THROUGH FIRE-RATED FLOOR/CEILING ASSEMBLIES. SEMI-RECESSED, WALL-MOUNTED INTERCOM SYSTEM, SEE ELECTRICAL DRAWINGS. MAINTAIN FIRE-RATING OF WALL. FULLY INSULATED AND GASKETED EXTERIOR DOOR, SEE DOOR SCHEDULE. COORDINATE EXACT ELEVATION OF DOOR WITH FLOOR / ROOF ELEVATION, SEE DETAIL. PROVIDE WOOD FRAMED STAIR WITH JOHNSONITE RUBBER STAIR TREADS, INTEGRAL NOSING AND LANDINGS TO MATCH. WOOD FRAMING SHALL HAVE CONTINUOUS VAPOR SEPERATION MEMBRANE FROM CMU SHAFT RAISED PLATFORM AT APARTMENT UNIT MECHANICAL ROOMS FOR VRP UNIT. PROVIDE 3-5/8" 20-GAUGE METAL STUD FRAMING AT GROUND FLOOR AND 2x4 WOOD STUD FRAMING AT FLOORS 2 THROUGH 5. PROVIDE MINERAL WOOD BATT INSULATION IN CAVITY FOR SOUND ISOLATION. RAISED PLATFORM SHALL PROVIDE PROPER ELEVATION TO MECHANICAL UNIT AS TO ALIGN WALL PENETRATION WITH EXTERIOR CLADDING SYSTEM. PROVIDE AND INSTALL CLOSET SHELVING, SEE SPECIFICATIONS. PROVIDE 3 5/8-INCH METAL STUDS WITH 5/8-INCH TYPE-X GYPSUM WALL BOARD CORRIDOR SIDE UP TIGHT TO UNDERSIDE OF DECK. ALIGN GYPSUM WALL BOARD TO ALIGN WITH ADJACENT FURRING AT PILASTER. PROVIDE 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. WALL AND WINDOWS ARE RECESSED AT THIS LOCATION, 3-5/8-INCH CLEAR FROM FRAME OF WINDOW TO EXTERIOR CLADDING, SEE DETAILS. RECESSED, WALL-MOUNTED VERTICAL MAILBOXES EQUAL TO 2B GLOBAL, INC.: USPS COLLECTION MODEL. PROVIDE ONE (1)MAILBOX FOR EACH APARTMENT UNIT (SIXTY (60) MAILBOXES TOTAL), TWO (2) ADDITIONAL MAILBOXES (ONE (1) FOR EACH COMMERCIAL TENANT), AND FOUR (4) PARCEL BOXES. FINISH SHALL BE NATURAL ANODIZED WITH ENGRAVED DOOR I.D., COORDINATE LABELING WITH OWNER AND ARCHITECT PRIOR TO ORDERING MAILBOXES. INSTALL ALL FRAMING AND BLOCKING AS REQUIRED TO ACCMMODATE INSTALLATION OF MAILBOXES. INSTALL MAILBOXES TO COMPLY WITH ANSI A117.1 FOR ACCESSIBILITY. PROVIDE AND INSTALL WALL-MOUNTED, HIGH / LOW ELECTRIC WATER COOLERS AND BOTTLE FILLING STATION, SEE PLUMBING DRAWINGS. WATER COOLERS SHALL COMPLY WITH ANSI A117.1. PROVIDE 1-HOUR FIRE-RESISTANCE-RATED PARTITION WALL TIGHT TO UNDERSIDE OF STAIR AT LOWEST LEVEL, TO PREVENT ACCESS TO OR ANY STORAGE BENEATH THE STAIR. PROVIDE AND INSTALL 42-INCH HIGH PARTIAL HEIGHT WALL (WALL TYPE 1) WITH 3 CM THICK QUARTZ SILL WITH 1-INCH OVERHANG AND 1/8-INCH EASED EDGES. PROVIDE AND INSTALL 32-INCH DEEP HPL WORKSURFACE AT 30-INCH A.F.F.. PROVIDE GUSSET SUPPORT AT 3 POINTS. PROVIDE AND INSTALL HPL CLOTHES FOLDING COUNTERTOP AT 30-INCH A.F.F.. FINISHED FLOORS SHALL SEAMLESSLY ALIGN. COORDINATE EXACT FINISH FLOOR ELEVATION BETWEEN CORRIDOR AND STAIR LANDINGS. 1A 1B 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 # WALL ASSEMBLY, SEE WALL SCHEDULE. CONCRETE WALL, SEE STRUCTURAL DRAWINGS. CMU WALL, SEE STRUCTURAL DRAWINGS. WINDOW / STOREFRONT / CURTAIN WALL, SEE ASSOCIATED SCHEDULES. NEW DOOR, SEE DOOR SCHEDULE. ACCESSIBLE APARTMENT: ACCESSIBLE TO MOBILITY IMPAIRED, SEE ENLARGED PLANS. AUDIBLE / VISUAL APARTMENT: ACCESSIBLE TO HEARING OR VISUALLY IMPAIRED, SEE ELECTRICAL DRAWINGS. LEGEND[REFLECTED CEILING PLANS] 000.01 S10 A/V plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. PLAN PROJECT No. DATE ©PLAN ARCHITECTURAL STUDIO, PC SHARS I.D. # 20186081 a105 FIFTH FLOOR PLAN 001.16.01.02 11.22.2019 LAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 CONSTRUCTION PERMIT DOCUMENTS SCALE: 1/8" = 1'-0" FIFTH FLOOR PLAN 1 N POST BID ADDENDUM #42020.01.31 A4 23'-11" 16'-1 1/8" 4'-9 5/8 19'-3 3/8" 4'-5 1/4" 9'-5 1/2" 14'-1 3/8" 10'-1 7/8" 30'-2 3/8" 11'-8 1/4" 22'-3 1/4" 7'-9 3/8" 3'-10 1/8" 12'-6 3/8" 10'-0 1/2" 22'-4 1/2" 14'-4 1/4" 6'-1 5/8" 11'-2 1/2" 12'-7 7/8" 22'-4 3/4" 14'-8 1/4" 6'-6 1/8" 11'-7 1/4" 12'-10 7/8" 23'-7 7/8" 15'-4 1/8" 19'-8 1/4" 6'-5 5/8" 11'-6 5/8" 13'-5 3/8" 23'-8 1/4" 14'-5 1/2" 6'-5 3/4" 11'-6 7/8" 12'-10 1/8" 8'-11 1/4" 23'-7 5/8" 14'-4" 6'-5 1/2" 11'-6" 12'-10 1/4" 8'-11 3/8" 23'-7 7/8" 14'-4 1/8" 6'-5 3/4" 11'-6 1/2" 8'-11" 12'-9 3/4" 23'-7 1/8" 14'-4 7/8" 6'-5" 11'-6 1/8" 12'-9 3/8" 8'-10 1/2" 23'-8 1/8" 14'-3 1/4" 6'-5 3/4" 11'-6 5/8" 12'-9 1/2" 8'-10 3/4" 23'-7 3/8" 14'-4 1/8" 6'-5" 11'-6" 12'-10 3/8" 8'-11 1/8" 23'-6 7/8" 14'-11 3/8" 6'-4 1/4" 11'-5 3/8" 16'-4 1/4" 12'-7 3/8" 23'-8 1/4" 13'-6 1/2" 18'-1 7/8" 11'-6 5/8" 6'-6 1/8" 8'-11" 12'-9 7/8" 11'-6 5/8" 23'-8 5/8" 14'-3 1/2" 5'-8 5/8" 18'-3 1/2" 6'-6" 17'-2 1/4" 11'-7 3/8" 13'-3 1/8" CofO As-Builts/Electrical As-Builts.pdf SYMBOL DESCRIPTION POWER DISTRIBUTION SURFACE/FLUSH MOUNTED BRANCH CIRCUIT PANELBOARD. 208Y/120V OR 240/120V. REFER TO PANELBOARD SCHEDULE MANUAL MOTOR STARTER OR MOTOR RATED SWITCH. DESIGNATION REFERS TO ELECTRIC EQUIPMENT AND CONTROL SCHEDULE NON-FUSED DISCONNECT SWITCH. DESIGNATION REFERS TO ELECTRIC EQUIPMENT AND CONTROL SCHEDULE ELECTRICAL SYMBOL DESCRIPTION DUPLEX RECEPTACLE, SUBSCRIPTS AS FOLLOWS: AFI CR EP GFI H IG SS WP TR WR USB ARC FAULT INTERRUPTER CORROSION RESISTANT EXPLOSION PROOF GROUND FAULT INTERRUPTER HOSPITAL GRADE ISOLATED GROUND SURGE SUPPRESSION WEATHER PROOF TAMPER RESISTANT WEATHER RESISTANT UNIVERSAL SERIAL BUS SYMBOL DESCRIPTION LIGHTING SINGLE POLE SWITCH WALL MOUNTED OCCUPANCY SENSOR SWITCH CEILING MOUNTED OCCUPANCY SENSOR. SUBSCRIPT INDICATES TYPE 2'X4' RECESSED LUMINAIRE. DESIGNATION REFERS TO LUMINAIRE SCHEDULE EMERGENCY REMOTE BATTERY PACK. DESIGNATION REFERS TO LUMINAIRE SCHEDULE SINGLE FACE UNIVERSAL MOUNTED EXIT SIGN. DESIGNATION REFERS TO LUMINAIRE SCHEDULE LA EM2 X1 LA SYMBOL LIST OS-A DECORATIVE SURFACE MOUNTED LUMINAIRE. DESIGNATION REFERS TO LUMINAIRE SCHEDULE THREE-WAY POLE SWITCH SUBSCRIPT INDICATES QUANTITY OF SWITCHES. REFER TO LUMINAIRES FOR SWITCHING DESIGNATIONS a,b LA 2'X2' RECESSED LUMINAIRE. DESIGNATION REFERS TO LUMINAIRE SCHEDULE LA WALL MOUNTED LUMINAIRE. DESIGNATION REFERS TO LUMINAIRE SCHEDULE LA JUNCTION BOX BELL OR BUZZER DOORBELL OR PUSHBUTTON 12 E-3 SYMBOL DESCRIPTION MISCELLANEOUS REFERENCE TO DRAWING NOTE REFERENCE TO EQUIPMENT OR FEEDER NUMBER DETAIL REFERENCE SYMBOL 2 2 SYMBOL DESCRIPTION COMMUNICATIONS SYMBOL DESCRIPTION FIRE ALARM MANUAL PULL STATION SMOKE DETECTOR VISUAL ONLY FIRE ALARM NOTIFICATION APPLIANCE AUDIO-VISUAL FIRE ALARM NOTIFICATION APPLIANCE SYMBOL DESCRIPTION LINE STYLES INDICATES UNDERGROUND TELEPHONE HEAT DETECTOR SPECIAL PURPOSE RECEPTACLE SECURITY KEYPAD LIGHTING CONTROL PANEL CARBON MONOXIDE DETECTOR LCP RAP PHOTOCELL MOTOR FIRE ALARM CONTROL PANEL REMOTE ANNUNCIATOR PANEL EMERGENCY DUPLEX RECEPTACLE FACP EMERGENCY BATTERY PACK. DESIGNATION REFERS TO LUMINAIRE SCHEDULE EM1 DUAL FACE UNIVERSAL MOUNTED EXIT SIGN. DESIGNATION REFERS TO LUMINAIRE SCHEDULE X2 LA DECORATIVE LINEAR PENDANT. DESIGNATION REFERS TO LUMINAIRE SCHEDULE LA DOWNLIGHT. DESIGNATION REFERS TO LUMINAIRE SCHEDULE INDICATES UNDERGROUND ELECTRIC INDICATES NEW DEVICE OR EQUIPMENT INDICATES UNDERGROUND CATV E T CATV LA POLE MOUNTED LUMINAIRE. DESIGNATION REFERS TO LUMINAIRE SCHEDULE 1'X4' SURFACE LUMINAIRE. DESIGNATION REFERS TO LUMINAIRE SCHEDULE LA M MS J DOUBLE DUPLEX RECEPTACLE EMERGENCY DOUBLE DUPLEX RECEPTACLE B EMERGENCY POWER OFF PUSHBUTTONEPO AREA OF REFUGE TV 120 VOLT CONNECTION TO EQUIPMENT TS S SD S/CO F H F F DH DSD DTS CO COMBINATION SMOKE/CARBON MONOXIDE DETECTOR DUCT SMOKE DETECTOR DUCT SMOKE DETECTOR TEST STATION SMOKE DAMPER DOOR HOLD OPEN TAMPER SWITCH FLOW SWITCHFS CARD READER DOOR STRIKE DOOR CONTACT ACCESS CONTROL PANELACP DS DC CR KP PC OS 3 EXTERIOR WALL MOUNTED LUMINAIRE. DESIGNATION REFERS TO LUMINAIRE SCHEDULE REFERENCE TO DEMOLITION NOTE2 INDICATES EXISTING DEVICE OR EQUIPMENT TO REMAIN INDICATES DEVICE OR EQUIPMENT TO BE REMOVED OR RELOCATED VOICE/DATA OUTLET. PROVIDE 2-GANG OUTLET BOX WITH SINGLE GANG MUD RING AND 1" CONDUIT TO ACCESSIBLE CEILING SPACE ABOVE. PROVIDE (2) CATEGORY 6 CABLES BACK TO TELEPHONE BACKBOARD. CATV OUTLET. PROVIDE 2-GANG OUTLET BOX WITH SINGLE GANG MUD RING AND 1" CONDUIT TO ACCESSIBLE CEILING SPACE ABOVE. PROVIDE (1) RG6/UCABLE BACK TO TELEPHONE BACKBOARD. TELEPHONE ONLY OUTLET. PROVIDE 2-GANG OUTLET BOX WITH SINGLE GANG MUD RING AND 1" CONDUIT TO ACCESSIBLE CEILING SPACE ABOVE. PROVIDE (1) CATEGORY 6 CABLE BACK TO TELEPHONE BACKBOARD. SYMBOL DESCRIPTION DIMMING SWITCHD AOR WALL MOUNTED VACANCY SENSOR SWITCH VS INTERCOM MASTER STATION INTERCOM SUB STATION IC IC S M CATV SPLITTER PATCH PANEL S PP GENERAL SITE NOTES APPLY TO ALL SITE ELECTRICAL DRAWINGS. COORDINATE NEW ELECTRICAL SERVICE ENTRANCE WITH NYSEG NEW TELEPHONE SERVICE WITH VERIZON AND NEW CATV SERVICE WITH SPECTRUM CABLE. OBTAIN ALL SPECIFICATIONS AND PAY ALL ASSOCIATED FEES. OBTAIN ALL PERMITS AND INSPECTIONS REQUIRED BY THE CITY OF ITHACA. THE ELECTRICAL CONTRACTOR SHALL ENGAGE THE SERVICES OF A QUALIFIED SUBCONTRACTOR FOR EXCAVATION, BACKFILL AND CONCRETE WORK. A MINIMUM OF TWO DAYS PRIOR TO EXCAVATION, CONTACT DIG SAFELY NEW YORK, INC (1-800-962-7962) AND OBTAIN A STAKEOUT OF ALL PUBLIC AND PRIVATE UTILITIES LOCATED IN THE AREA OF EXCAVATION. COORDINATE PRIVATE UTILITIES WITH THE OWNER PRIOR TO EXCAVATION. HAND EXCAVATE ADJACENT EXISTING UTILITIES INCLUDING STORM AND SANITARY SYSTEMS TO AVOID DAMAGE. REPORT ANY DAMAGED UTILITIES TO THE OWNERS REPRESENTATIVE IMMEDIATELY. PROVIDE BRACING, SHORING, SHEATHING AND OTHER WORK FOR PROTECTION OF PERSONNEL, THE CONTRACT WORK, EXCAVATIONS, TREES, SHRUBS, EXISTING STRUCTURES, AND SURROUNDING PROPERTIES. PROVIDE AND MAINTAIN BARRICADES, WARNING SIGNS, FLAGS, AND LIGHTS TO PROVIDE PROTECTION FOR WORK, WORKMEN, PUBLIC, AND PROPERTY. COORDINATE PARKING LOT AND/OR PARKING GARAGE DISRUPTIONS WITH THE OWNER IN ADVANCE. PROVIDE PUMPS, HOSES, PIPE, LABOR AND FUEL NECESSARY TO KEEP EXCAVATIONS FREE OF WATER ACCUMULATION. OPERATE AND MAINTAIN EQUIPMENT. DISCHARGE WATER IN MANNER NOT TO UNDERMINE OR DISTURB EXISTING OR ADJACENT STRUCTURES OR LAND. DO NOT DISCHARGE DIRT, BACKFILL, DEBRIS, INTO SANITARY OR STORM DRAINAGE SYSTEMS. INSTALL TELEPHONE, CABLE AND ELECTRIC CONDUITS AS STRAIGHT AS POSSIBLE. INSTALL CONDUITS BELOW SITE LIGHTING CONDUITS AND GAS LINES AND ABOVE WATER, STORM, AND SANITARY PIPING. TRANSITION ALL CONDUITS TO GRS PRIOR TO RISING ABOVE GRADE. MAINTAIN ROAD ACCESS AT ALL TIMES. PROVIDE STEEL PLATES OVER TRENCH AS REQUIRED. PROTECT UTILITIES, SIDEWALKS, STRUCTURES, PAVEMENTS AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLING, LATERAL MOVEMENTS, UNDERMINING, WASHOUTS AND OTHER HAZARDS CREATED BY EXCAVATION WORK. COMPLETELY RESTORE THE AREA TO THE CONDITION PRIOR TO THE START OF EXCAVATION AND TRENCHING WORK. GENERAL SITE NOTES: A. B. C. D. E. F. G. H. I. J. K. L. M. N. CATV SCOPE OF WORK: PROVIDE RG11/U COAXIAL CABLE FROM THE CATV SERVICE ENTRANCE LOCATION TO EACH SPLITTER IN SERVER/IT ROOM. PROVIDE TERMINATIONS AT EACH END. IN EACH APARTMENT, PROVIDE A CATV SPLITTER IN THE APARTMENT MECHANICAL CLOSET. PROVIDE RG6/U COAXIAL CABLE FROM THE SPLITTER IN THE MECHANICAL CLOSET TO EACH CATV OUTLET IN THE APARTMENT. PROVIDE TERMINATIONS AT EACH END. 1. 2. 3. DATA WIRING SCOPE OF WORK: PROVIDE (2) 48 PORT, CATEGORY 6 PATCH PANELS IN EACH OF (5) IT ROOMS. PATCH PANEL SHALL BE WALL MOUNTED IN SERVER ROOM 008A. PROVIDE ALL CATEGORY 6 DATA CABLES. PROVIDE ALL TERMINATIONS AT EACH END. PROVIDE ALL LABELING AND TESTING. PROVIDE ALL COVER PLATES. COORDINATE COVER PLATE MANUFACTURER WITH THE TELEPHONE SYSTEM SUPPLIER. 1. 2. 3. 4. 5. VOICE WIRING SCOPE OF WORK: 1. 2. 3. 4. ALL CABLING SHALL BE CATEGORY 6, WITH RJ45 CONNECTORS AND A COVER PLATE. TEST AND LABEL EACH CABLE. THERE IS ONE SERVER ROOM ON THE GROUND FLOOR. PROVIDE A WALL MOUNTED RACK WITH HORIZONTAL AND VERTICAL WIRE MANAGEMENT IN EACH CER. PROVIDE RACK MOUNTED CATEGORY 6 PATCH PANELS AS REQUIRED. AT EACH COMMON AREA VOICE/DATA OUTLET, PROVIDE (2) CATEGORY 6 CABLES BACK TO THE SERVER ROOM. TERMINATE EACH CABLE AT A PATCH PANEL. IN EACH APARTMENT, PROVIDE THE FOLLOWING: PROVIDE A WALL MOUNTED, 12-PORT CATEGORY 6 PATCH PANEL. PROVIDE (1) CATEGORY 6 CABLE FROM THE APARTMENT PATCH PANEL BACK TO THE SERVER ROOM AND TERMINATE AT A PATCH PANEL. FROM EACH APARTMENT VOICE/DATA OUTLET, PROVIDE (2) CATEGORY 6 CABLES FROM THE OUTLET TO THE APARTMENT PATCH PANEL. FROM EACH APARTMENT TV DATA OUTLET, PROVIDE (1) CATEGORY 6 CABLE FROM THE OUTLET TO THE APARTMENT PATCH PANEL. NO SCALE 1 POWER ONE-LINE WIRING DIAGRAM METER CENTER UTILITY TRANSFORMER SECONDARY 208Y/120V, 3 PHASE M SPD 35 LOAD CENTERS REQUIRED 200A/3P LVPH1 (SEC 1) TWO CHANNEL METER SECTION WITH (2) 200A/3P OUTPUT CIRCUIT BREAKERS FOR HOUSE AND HORIZON METER CENTER 1600A/3P M 200A/3P LVPHZ 3/C #2, 1-#4EG ALUMINUM TYPE SE CABLE M 100A/2P M 100A/2P M 100A/2P LCP**LCP**LCP** M 100A/2P M 100A/2P LCP**LCP** M 100A/2P M 100A/2P M 100A/2P LCP**LCP**LCP** M 100A/2P M 100A/2P LCP**LCP** METER CENTER FIVE-CHANNEL METER SECTION WITH 100A/2P OUTPUT CIRCUIT BREAKERS (TYP OF 5) 1600A/3P MAIN CIRCUIT BREAKER 208Y/120 VOLTS 3 PHASE, 4 WIRE INPUT, 65KAIC SERVICE ENTRANCE RATED FIVE-CHANNEL METER SECTION WITH 100A/2P OUTPUT CIRCUIT BREAKERS (TYP OF 7) LVPH4 5 SETS OF 4-500KCM IN (6) 4" PVC-80, DB ST 60A/3P ELEV-1 NF 60AS 3-#6, 1-#10EG IN 1”C 60AF 60AS LVPEM G 60A/3P 200A/3P EG-1 60KW/75KVA 208Y/120V 3 PHASE, 4 WIRE NATURAL GAS 4-#3/0, 1-#6EG IN 2½"C 4-#4/0, 1-#4EG IN 4" C ATS-EM 208Y/120V 200A/3P 25 LOAD CENTERS REQUIRED ATS-LS 208Y/120V 60A/3P 4-#6, 1-#10EG IN 1"C 200A/3P 60A/3P LVPLS 4-#4, 1-#8EG IN 4" C 4-#6, 1-#10EG IN 1"C 4-#3/0, 1-#6EG IN 2½"C PROVIDE FEED THRU LUGS LVPH1 (SEC 2) 4-#3/0, 1-#6EG IN 2½"C 4-#3/0, 1-#6EG IN 2½"C UTILITY POLE NYSEG POLE #2263 -#2AWG, 15KV SHIELDED COPPER CABLE WITH 175 MIL INSULATION AND 1-#2AWG NEUTRAL IN (2) 4" PVC-80, DIRECT BURIED. TERMINATIONS BY NYSEG. 30A/2P LCS 2-#8, 1-#10EG IN 1” PVC-80 M 60A/2P LVPELM 3/C #4, 1-#6EG ALUMINUM TYPE SE CABLE PROVIDE METER SOCKET WITH 60A/2P CIRCUIT BREAKER A17 RANGE/COOKTOP BY OTHERS LIGHT SWITCH FAN SPEED KNOB LED STATUS LIGHT RESET SWITCH 7" DIAM. EXHAUST DUCT BY HVAC CONTRACTOR BACK SUPPORT MOUNTING BRACKET BY HVAC CONTRACTOR JUNCTION BOX BY HVAC CONTRACTOR FIRE ALARM CONNECTION BY OTHERS COORDINATE EXACT LOCATION OF MANUAL PULL STATION WITH OWNER'S REPRESENTATIVE LEGEND: JUNCTION BOX BY OTHERS MANUAL POWER SWITCH EXTINGUISHER PRESSURE GAUGE POWER SUPPLY BY ELECTRICAL CONTRACTOR ELECTRICAL DISCONNECT BY HVAC CONTRACTOR 208 VOLT WIRING BY ELECTRICAL CONTRACTOR MANUAL PULL STATION CABLE BY HVAC CONTRACTOR 50A CONTACTOR/SHUNT TRIP BREAKER FURNISHED BY HVAC CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR 120 VOLT WIRING BY ELECTRICAL CONTRACTOR MOUNT HOOD 24"-36" ABOVE COOKING SURFACE MANUAL PULL STATION AND CABLE BY HVAC CONTRACTOR DUCT ACCESS DOOR DUCT ACCESS DOOR ROUTE DUCT TO EXTERIOR AS DIRECTLY AS POSSIBLE DUCT MOUNTED INLINE FAN FURNISHED WITH HOOD SYSTEM. LOCATE IN ACCESSIBLE LOCATION. SEE CUT FOR FAN DIMENSIONS REFER TO SPECIFICATION SECTION 233110 - GREASE DUCT SYSTEMS FOR DUCT CONSTRUCTION REQUIREMENTS PROVIDE CURRENT SENSING RELAY ON POWER LINE AND CONNECT TO BUILDING DDC SYSTEM FOR HOOD FAN STATUS MONITORING AND VAV BOX CONTROL. PROVIDE INTER-CONNECTING CONTROL WIRING ½" CONDUIT PROVIDED BY ELECTRICAL CONTRACTOR PULL NO SCALE 2 TYPICAL RESIDENTIAL KITCHEN EXHAUST HOOD DETAIL - INLINE FAN plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e001 ELECTRICAL GENERAL NOTES AND SYMBOLSLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.30.2020 ELECTRICAL GENERAL NOTES A. GENERAL NOTES APPLY TO ALL ELECTRICAL DRAWINGS. B. PROVIDE UPDATED TYPE WRITTEN PANELBOARD SCHEDULES FOR ALL PANELS USED IN THIS PROJECT. C. INSTALL ALL DEVICES FLUSH IN WALL CONSTRUCTION. D. PROVIDE BLANK COVERPLATES ON ALL EXISTING AND NEW UNUSED OUTLET BOXES. E. COORDINATE ALL CONDUIT RUNS WITH OTHER TRADES PRIOR TO ROUGH-IN. RELOCATE ANY CONDUITS AS NECESSARY TO PERMIT INSTALLATION OF DUCTWORK, PIPING OR ANY SUPPORTS. F. PROVIDE CUTTING, PATCHING TO MATCH, AND FIRE SEAL AS REQUIRED WHERE EXISTING COMMUNICATION OR ELECTRICAL WORK HAS BEEN REMOVED AND WHERE NEW WORK IS INSTALLED. COORDINATE WITH GENERAL CONTRACTOR. G. REMOVE AND REINSTALL EXISTING CEILING TILES AS REQUIRED FOR INSTALLATION OF BRANCH CIRCUIT WIRING AND CONDUIT. REPLACE ALL DAMAGED TILES WITH MATCHING TILES. H. RUN ALL WIRING CONCEALED IN WALL. CUT AND PATCH TO MATCH DRYWALL AS REQUIRED. MINIMIZE USE OF SURFACE METAL RACEWAY. I. COORDINATE MOUNTING HEIGHTS OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND OWNER PRIOR TO ROUGH-IN. J. REFER TO ARCHITECTURAL PLANS FOR PHASING. K. PROVIDE "J" HOOKS ON 5' CENTERS TO SUPPORT VOICE/DATA CABLING. L. PROVIDE TAMPER RESISTANT RECEPTACLES IN ALL APARTMENT. M. FIRESTOP ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. SEE ARCHITECTURAL DRAWINGS CODE COMPLIANCE PLAN. 1 HR FIRE PARTITIONS: A. DEMISING WALLS BETWEEN APARTMENT UNITS AND CORRIDORS B. WALLS BETWEEN APARTMENT UNITS C. FLOOR/CEILING ASSEMBLIES IN RESIDENTIAL AND CORE D. CEILING/ROOF ASSEMBLIES IN RESIDENTIAL AND CORE E. STAIRS 1 HR. FIRE BARRIER WALLS: A. ELEVATOR ROOM B. STAIR WALLS 2 HR. FIRE BARRIER WALLS: - SEE ARCHITECTURAL CODE COMPLIANCE PLANS N. ALL BRANCH CIRCUITS IN APARTMENTS SHALL BE FED FROM A 15A/1P CIRCUIT BREAKER UNLESS NOTED OTHERWISE. ALL 15A/1P BRANCH CIRCUITS SHALL BE FED WITH #14 AWG WIRE. O. ALL BRANCH CIRCUITS IN COMMON AREAS SHALL BE FED FROM A 20A/1P CIRCUIT BREAKER UNLESS NOTED OTHERWISE. ALL 20A/1P BRANCH CIRCUITS SHALL BE FED WITH #12 AWG WIRE. POST BID ADDENDUM #3 2019.12.31 REVISIONS No. Description Date A1 A-1 Addendum 10.23.2019 A3 POST BID ADDENDUM #3 12.19.2019 A6 PRIMARY SER CHANGE 04.28.20 A7 SITEWORK & STORAGE SHED 05.15.2020 A17 ELMSHADE METER 04.19.2021 T G G G G G 10' REAR YARD SETBACK 10' SIDE YARD SETBACK 28.48' 7.92 WEST COURT STREET NORTH MEADOW STREET SLAGHT (R.O.) 615/906 TAX MAP PARCEL No. 59-2-8 CIASCHI (R.O.) 482211-001 TAX MAP PARCEL No. 59-2-16.1 TOMPKINS COMMUNITY ACTION (R.O.) 2500/1900 TAX MAP PARCEL No. 59-2-14 PARCEL B CURB CUT C.O. C.O. C.O. C.O. C.O. C.O. W W W W W W D D D D D D CCTV CCTV CCTV CCTV CCTV CCTV VS PC 1" PVC-80, DB (TYP) 3-#2AWG, 15KV SHIELDED COPPER CABLE WITH 175 MIL INSULATION AND 1-#2AWG NEUTRAL IN (2) 4" PVC-80, DIRECT BURIED. TERMINATIONS BY NYSEG. (2) 4" PVC-80, DB FOR TELEPHONE AND CATV 5 SETS OF 4-500KCM IN (6) 4" PVC-80, DB 4 e701 3 e701 --5 e701 3 e701 3 e701 8 e701 UTILITY TRANSFORMER BOLLARD (TYP) 11 e701 2 e701 2 e701 1 e701 2 e701 WP WP WP WP WP UNDER CANOPY LU LU LU LU LT LTLTLTLTLT LVPH1/6,8 12 e701 3 e702 #10#10 #10 #10 #10 #10 #10 #10 #10 PROVIDE 2-#8, 1-#10EG IN 1” PVC-80, DIRCT BURIED FOR POWER AND LIGHTING TO UTILITY SHED, TO A 30A/2P CIRCUIT BREAKER IN PANEL LVPH1. TERMINATE CONDUIT AT PANEL AND PROVIDE PULL STRING. 2 e701 #10 1" PVC-80, DB (TYP FOR BOLLARD LIGHTING) 4 e701 3 e701 A6 e100 2 A7 LI 48" GFI WP GFI PROVIDE SURFACE MOUNTED RACEWAY AND OUTLET BOXES AS REQUIRED. WP GFI LO LQ LQ LCS/1 CONNECT VIA PHOTOCELL CONNECT VIA PHOTOCELL LCS LCS/2 plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e100 SITE PLAN -ELECTRICALLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.22.2019 1/16" = 1'-0" 1 SITE PLAN - ELECTRICAL N REVISIONS No. Description Date A6 PRIMARY SER CHANGE 04.28.20 A7 SITEWORK & STORAGE SHED 05.15.20201/4" = 1'-0"2 ENLARGED SHED - ELECTRICAL A7 TOTAL EST. DEMAND: 3 A TOTAL CONN.: 3 A TOTAL EST. DEMAND: 615 VA Receptacle 540 VA 100.00% 540 VA TOTAL CONN. LOAD: 624 VA Lighting 84 VA 90.00% 75 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 5 A 0 A TOTAL LOAD: 624 VA 0 VA 7 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 8 5 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 6 3 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 4 1 SHED LTG 20 A 1 0.1 0.5 1 20 A SHED RECEPT 2 CKT CIRCUIT DESCRIPTION TRIP POLES A (kVA) B (kVA) POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LCS LVPH1 100 A 1Ø, 3W 120/208... SURFACE 10 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE:PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD A7 SHED W W W W W W D D D D D D OS OS OS VSDVSD VSD VSD VSD VS VS VSVS D D OS 3 D VSD VSD D OS-A OS-A OS-A OS-A OS-B OS-B OS-A OS-A OS-A OS-A OS OS D 3D OS-A OS-A PC VS 010 MECHANICAL AND ELECTRICAL 006A PROGRAM MANAGER'S OFFICE 006 ELMSHADE OFFICES 009 BUILDING MAINTENANCE OFFICE B01 STAIR B 100C CORRIDOR 008 SERVER 007 ELMSHADE MED. ROOM 005 STAFF TOILET 002E SUPPORTIVE HOUSING OFFICE 004 SHARED COPY / FILES 002A HORIZON PROGRAM 002D DIRECTOR'S OFFICE 002C PROGRAM MANAGER'S OFFICE 002B HORIZON MED. ROOM E01 ELEVATOR 011 TRASH / RECYCLE 002 HORIZON WAITING AREA 003 RECEPTION OFFICE 100C CORRIDOR 001 VESTIBULE 018 CONFERENCE ROOM 017 COMMON LAUNDRY 016 MEN'S TOILET 015 WOMEN'S TOILET A01 STAIR A 100D VESTIBULE 014 STAFF BREAK ROOM 013 COMMUNITY KITCHEN 012 COMMUNITY ROOM 1 e601 1 e601 1 e601 1 e601 LVPHZ LK LK LK LK LK LK LJ X1 X1 LH LH LI LI LI LI LI LI LH LG LH X2 X1 LL LL LL X1 X2 X1 LG LG LL X1 LG LG LL LL LL LN LN LN LMLMLMLMLM LM LM LM LN LL LL LM LM X1 LG LG LG LG LG LGLGLGLGLGLG 101 (TYPE 1A) 1-BEDROOM APARTMENT 102 (TYPE 2A) 1-BEDROOM APARTMENT 103 (TYPE 2A) 1-BEDROOM APARTMENT 104 (TYPE 2A) 1-BEDROOM APARTMENT LN LN LVPLS LVPEM LK LK LK LK LK LK LK LK LK LK LK LK LP LP LK LK LK LK LK LK LK LK LK LK LK LK LK 1 1 1 1 1 1 1 1 1 1 1 1 1 LO LQ LQ LQLQ LQ LQLQLQ LQLQ LQ LQLQ LQ LQ LQ LQ LQ EQ EQ LN 1 LQ LQ LQ 2 LVPLS/3 2 2 2 2 2 2 LVPLS/8 LVPLS/8 2 2 a,b b a a aa aa a,b a,b LVPLS/8 7'-8"AFF C 6'-5" AFF C L L 7'-8"AFF C L 7'-8"AFF C L 7'-8"AFF C L LP LP LP LP LPLP LP LPLP LP LP LVPHZ/1 LVPLS/6 LVPH1/2 2 2 2 LVPLS/8 LVPH1/4 LP LP LQLQLQ 3 e703 3 e703 3 e703 3 e703 LCP LH 1 2 3 4 5 6 7 8 10 11 12 14 13 16 A C D E F G H I A.5 B 7.6 B.1 15.5 15.6 H.3 3 e703 9 22 LVPLS/7 1 X1 X1 X1 X1 X1 X1 X1 LVPH1 (2 SECTION) 3 e703 E.10 020 CUST. LC EM EM EM EM EM EM EM EM EM EM EM EM EM EM EMEM EM EM EM EM EMEMEM EM EMEM EM EM EM1 3 EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EMEM EM EM EM EM LVPELM/1 A17 LVPELM plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e101 GROUND FLOOR PLAN -LIGHTINGLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.30.2020 1/8" = 1'-0" 1 GROUND FLOOR PLAN - LIGHTING e101 LIGHTING DRAWING NOTES 1 PROVIDE EXIT SIGN AND CONNECT TO A 20A/1P CIRCUIT BREAKER IN PANEL LVPLS/2 USING 2-#12, 1-#12EG IN 1/2" CONDUIT. LOCK CIRCUIT BREAKER IN ON POSITION. 2 CONNECT LUMINAIRE TO LIFE SAFETY BRANCH CIRCUIT IN PANEL LVPLS, CIRCUIT 4. 3 PROVIDE BATTERY BACK UP LUMINAIRE. CONNECT TO LIFE SAFETY LIGHTING BRANCH CIRCUIT AHEAD OF ALL SWITCHING. N # POST BID ADDENDUM #3 2019.12.31 REVISIONS No. Description Date A1 A-1 Addendum 10.23.2019 A3 POST BID ADDENDUM #3 12.19.2019 A17 ELMSHADE METER 04.19.2021 W W W W W W D D D D D D F F F F F F F FF F F F FF F S H H S S H S SSSS S F F F F F H S H S TV TV DC DC DC CR CR CR CR CR DS DS DS DS CCTV CCTV CCTV CCTV CCTV CCTV CCTV CCTV CCTV CCTVCCTV CR DC PB PB DS DC PB PB DC DC CO CO CO M MM MS M SMS F A DS DC M M M M S MS MS M M M M M M M M M CO M MS MS MS M S MS MS MS MS MS MS M M S M M M M M M FSFSFS TSTSTS TS FS MS M M M F SD SD S D S D DTSDTS KP HD HD HD CR DS DC DS CR HD HD MS M M MS F IC CR CR CR DS DS CCTV DC DCDS DC J T 010 MECHANICAL AND ELECTRICAL 006A PROGRAM MANAGER'S OFFICE 006 ELMSHADE OFFICES 009 BUILDING MAINTENANCE OFFICE B01 STAIR B 100C CORRIDOR 008 SERVER 007 ELMSHADE MED. ROOM 005 STAFF TOILET 002E SUPPORTIVE HOUSING OFFICE 004 SHARED COPY / FILES 002A HORIZON PROGRAM 002D DIRECTOR'S OFFICE 002C PROGRAM MANAGER'S OFFICE 002B HORIZON MED. ROOM E01 ELEVATOR 011 TRASH / RECYCLE 002 HORIZON WAITING AREA 003 RECEPTION OFFICE 100C CORRIDOR 001 VESTIBULE 018 CONFERENCE ROOM 017 COMMON LAUNDRY016 MEN'S TOILET 015 WOMEN'S TOILET A01 STAIR A 100D VESTIBULE 014 STAFF BREAK ROOM 013 COMMUNITY KITCHEN 012 COMMUNITY ROOM 1 e601 1 e601 1 e601 1 e601 44" GFI TR TR WP GFI WP GFI WP GFI WP GFI GFI e704 4 LVPEM LVPH1 ATS-E LVPHZ 46" 46" TR 46" GFI TR 101 (TYPE 1A) 1-BEDROOM APARTMENT 102 (TYPE 2A) 1-BEDROOM APARTMENT 103 (TYPE 2A) 1-BEDROOM APARTMENT 104 (TYPE 2A) 1-BEDROOM APARTMENT ATS-LS LVPLS AUX BOTTOM OF SHAFT ¼" X 4" X 12" GROUND BAR AT 7'-0"AFF 4 e702 5 e702 2 3 4 BCC-1 44" GFI GFI 44" GFI GFI SUMP PUMP LVPEM/1 FCU-8 FCU-7 FCU-6 FCU-5 FCU-2 FCU-4 FCU-1 FCU-3 PANIC PUSHBUTTON REPEATER ADA - TYPE 1 (TYP FOR 1ST, 3RD AND 5TH FLOOR ONLY) SIM. GENERATOR RAP 48" 48" 48" 48" LVPEM/6 LVPEM/8 LVPELM/2 LVPELM/4 LVPH1/7 LVPHZ/2 LVPHZ/3 LVPHZ/4 LVPHZ/5 LVPHZ/7 LVPELM/3 LVPH1/28,30 LVPH1/21,23 LVPH1/32,34 LVPH1/25,27 LVPH1/36,38 LVPH1/29,31 LVPH1/26 LVPH1/15 LVPH1/19 LVPH1/24 LVPH1/17 LVPH1/22 LVPLS/3 LVPH1/9 LVPH1/14 LVPHZ/6 TR TR TR TR TR TR TR TR TR TR TR TRTRTR 46" TR 46" TR 46" TR 46" TR46" TR TR LVPEM/12 LVPEM/3 LVPH1/11 HW-3 HWRP-1 23 5 WP 1 5 6 48" LCP 30 10 11 12 13 14 15 16 17 EF-3 EF-2 EF-2 41 40 42 PANIC ALARM BY OWNER 7 8 HW-2HW-1 4 EBB-4 EBB-4 EBB-4 EBB-4TEBB-4T EBB-4T 31 BCC-2 50 51 52 53 54 55 1 2 3 4 5 6 7 8 10 11 12 14 13 16 A C D E F G H I A.5 B 7.6 B.1 15.5 15.6 H.3 9 MCB 99 ECUH-1 ECUH-1 UH-1 60 61 63 10 10 LVPEM/14 LVPLS/9 (2 SECTION) ACCESS CONTROL KEYPAD GFI WINDOW SPEAKER LVPH1/65 LVPH1/55 LVPH1/57 020 CUST. LVPLS/10 LVPH1/1 LVPEM/2 LVPEM/4 LVPHZ/8 LVPELM/6 e102 2 E.10 LVPH1/16 46" GFI 46" GFI LVPLS/1 48" FACP LVPEM/24 LVPH1/18 LVPH1/60 e102 3 VRP-12KB LC***/9,11 30A/2P TYPICAL FOR FIRST FLOOR APARTMENTS ONLY FD/SD LVPEM/13 EF-2 47 eSK003 1 LVPH1/5LVPH1/3 PROVIDE (1) 208/120V, 60A/2P, SINGLE PHASE METER SOCKET. LVPELM/5 A17 A17 LVPELM 14 A.5 B B.1 48" AOR M ECUH-1 62 E.10 LVPEM/10 FARAP 001 VESTIBULE 1615.5 15.6 H.3 10 LVPH1/61,63 2 e001 46" GFI TR 46" GFI TR 46" GFI TR LVPH1/13 LVPH1/59 MICROWAVE 11 12 DISHWASHER LVPH1/66 plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e102 GROUND FLOOR PLAN -POWER AND SYSTEMSLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.30.2020 1/8" = 1'-0" 1 GROUND FLOOR PLAN - POWER AND SYSTEMS e102 ELECTRICAL DRAWING NOTES 1 SPRINKLER ALARM PROVIDED BY OTHERS. CONNECT TO FIRE ALARM SYSTEM. 2 PROVIDE 4'x8'X3/4" PLYWOOD BACKBOARD AT 6" A.F.F. PAINT WITH 2 COATS FIREPROOF GRAY PAINT. 3 PROVIDE 4" SLEEVE ABOVE ACCESSIBLE CEILING SPACE. FIRE STOP AS REQUIRED. 4 PROVIDE 4" CONDUIT UP TO SECOND FLOOR ACCESSIBLE CEILING SPACE FOR TEL/DATA CABLING. 5 PROVIDE AMBER STROBE FOR CO DETECTION. 6 PROVIDE TRIPLE SERVICE RECESSED FLOOR BOX. SAW CUT FLOOR AS REQUIRED. PROVIDE (3) 1"C FROM THE FLOOR BOX TO THE CEILING SPACE. 7 LOCATION OF CAMERA IN ELEVATOR CAB. COORDINATE WITH ELEVATOR INSTALLER. 8 PROVIDE WALL MOUNTED DATA EQUIPMENT CABINET. 9 PROVIDE METER CENTER BUS TRANSITION SECTION TO TURN CORNER WITH THE METER CENTER. 10 PROVIDE NEMA 14-50R RECEPTACLE FOR RANGE. PROVIDE 3/C #6+ #10EG TYPE NM CABLE FROM A 50A/2P CIRCUIT BREAKER IN PANEL. PROVIDE POWER TO THE KITCHEN HOOD POWER DISCONNECT BOX (PDB). THE PDB IS PROVIDED WITH THE KITCHEN HOOD. INSTALL AT FLOOR LEVEL. CONTROL PDB UTILIZING A 120 MINUTE DIGITAL INTERVAL TIMER SWITCH. REFER TO THE DETAILS AND KITCHEN HOOD INSTALLATION MANUAL. 11 PROVIDE TWO SWITCHES TO CONTROL THE HOOD LIGHT AND THE OTHER TO CONTROL THE HOOD EXHAUST FAN. CONNECT TO KITCHEN RECEPTACLE CIRCUIT. INSTALL IN CABINET VALANCE FACE. PROVIDE STAINLESS STEEL COVER PLATE AND BLACK SWITCHES. 12 PROVIDE 120 MINUTE DIGITAL INTERVAL TIMER SWITCH TO POWER DISTRIBUTION BOX (PDB) FOR SHUTDOWN OF POWER TO THE RANGE. REFER TO DETAILS AND KITCHEN HOOD INSTALLATION MANUAL. N # 1/4" = 1'-0" 2 VESTIBULE PLAN - POWER AND SYSTEMS 1/4" = 1'-0" 3 PARTIALCOMMUNITY KITCHEN PLAN - POWER AND SYSTEMS REVISIONS No. Description Date A1 A-1 Addendum 10.23.2019 A12 PANEL LOCATIONS 10.26.2020 A13 RFI 080 - COMM DW 11.30.2020 A17 ELMSHADE METER 04.19.2021 F F F F F F F S S S SS VS S OS-A OS-A OS-B OS-B OS-B OS-B OS-B SSSS VS H TV CCTV CCTV CCTV CCTV S S/CO S S S CCTVCCTVCO CO CO CO COM M M S DTS MS FS S D S D SD SD DTS DTS VS MS M M MS 200 CORRIDOR A02 STAIR A 215 TRASH / RECYCLE E01 ELEVATOR 200A RECEPTION LOUNGE e601 3 e601 2 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 e601 1 48" AOR AUX 202 (TYPE 4) 1-BEDROOM APARTMENT 201 (TYPE 3) 1-BEDROOM APARTMENT 203 (TYPE 2) 1-BEDROOM APARTMENT 204 (TYPE 2) 1-BEDROOM APARTMENT 206 (TYPE 2) 1-BEDROOM APARTMENT 205 (TYPE 2) 1-BEDROOM APARTMENT 207 (TYPE 2) 1-BEDROOM APARTMENT209 (TYPE 2) 1-BEDROOM APARTMENT 208 (TYPE 2) 1-BEDROOM APARTMENT 210 (TYPE 2) 1-BEDROOM APARTMENT 212 (TYPE 2) 1-BEDROOM APARTMENT 213 (TYPE 2) 1-BEDROOM APARTMENT 200 CORRIDOR TR TR TR TR TR TRTR TR 8'-0" AFF C L 8'-0" AFF C L 8'-0" AFF C L 8'-0" AFF C L LG LG LHLH LG X2 X1 LG LG X2 LG LG LGLGLGLGLGLGLGLGLGLGLGLGLG LH LH LG LG LG 216 I.T. CLOSET 217 CUST. LK LK LK LK 7 1 1 1 1 X1 LI 214 (TYPE 2) 1-BEDROOM APARTMENT B02 STAIR B C02 CHASE 211 (TYPE 2) 1-BEDROOM APARTMENT H/VI PANIC PUSHBUTTON REPEATER FCU-9 e601 4 (TYP FOR 2ND AND 4TH FLOOR ONLY) A/VB A/VB 9 9 2 2 9 99 2 2 9 3 3 4 4 4 4 1 e801 5 LVPH1/20 LVPH1/4 6 18 EF-3 LVPEM/5 8 TOP OF 5TH FLOOR STAIRWELL ONLY PROVIDE (1) DUCT TEST STATION ON 5TH FLOOR ONLY FOR DOAS UNIT 43 1 2 3 4 5 6 7 8 10 11 12 14 13 16 A C D E F G H I A.5 B 7.6 B.1 15.5 15.6 H.3 9 5TH FLR ONLY 10 PROVIDE (2) DUCT TEST STATIONS ON EACH FLOOR FOR SMOKE DAMPER DUCT DETECTORS E.10 LVPLS/9 8'-0" AFF C L LI EF-3 48 48" AOR 1 e801 300 CORRIDOR 2 3 4 A C D A.5 B B.1 B03 STAIR B 316 I.T. CLOSET BCC-332 E.10 317 CUST. plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e103 TYPICAL FLOORS 2 -5 -ELECTRICALLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 709 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.22.2019 1/8" = 1'-0" 1 TYPICAL SECOND THRU FIFTH FLOOR PLAN - ELECTRICAL e103 ELECTRICAL DRAWING NOTES 1 PROVIDE EXIT SIGN AND CONNECT TO A 20A/1P CIRCUIT BREAKER IN PANEL LVPLS/2 USING 2-#12, 1-#12EG IN 1/2" CONDUIT. LOCK CIRCUIT BREAKER IN ON POSITION. 2 CONNECT LUMINAIRE TO LIFE SAFETY BRANCH CIRCUIT IN PANEL LVPLS, CIRCUIT 4. 3 ON SECOND AND FOURTH FLOORS ONLY, PROVIDE 120VAC, SMOKE DETECTOR IN BEDROOM AND COMBINATION SMOKE AND CO DETECTOR OUTSIDE BEDROOM, WITH AUDIBLE AND VISUAL BASE AND BATTERY BACK-UP. CONNECT BRANCH CIRCUIT TO THE LIGHTING CIRCUIT AHEAD OF ALL SWITCHING. PROVIDE WIRING BETWEEN THE DEVICES SUCH THAT IF ONE DEVICES GOES INTO ALARM, ALL AUDIBLE AND VISUAL BASES WILL SOUND. 4 ON SECOND AND FOURTH FLOORS ONLY, MOUNT DOORBELL WITH STROBE AT 80" ABOVE FINISHED FLOOR TO BOTTOM OF BOX. CONNECT TO DOORBELL PUSHBUTTON. 5 CONNECT TO LVP4/ CIRCUIT 1 FOR 3RD FLOOR, CIRCUIT 3 FOR 4TH FLOOR, AND CIRCUIT 5 FOR 5TH FLOOR RECEPTACLE CIRCUITS. 6 CONNECT TO LVP4 CIRCUIT 2 FOR 3RD, 4TH, AND 5TH FLOORS LIGHTING CIRCUIT. 7 PROVIDE 4" SLEEVE ABOVE ACCESSIBLE CEILING SPACE. FIRE STOP AS REQUIRED. 8 CONNECT TO LVPEM/ CIRCUIT 7 FOR 3RD FLOOR, CIRCUIT 9 FOR 4TH FLOOR, AND CIRCUIT 11 FOR 5TH FLOOR RECEPTACLE CIRCUITS. 9 CONNECT LUMINAIRE TO LIFE SAFETY BRANCH CIRCUIT IN PANEL LVPLS, CIRCUIT 6. 10 LOCATION OF SMOKE DAMPER PROVIDED BY DIVISION 23. PROVIDE120 VOLT BRANCH CIRCUIT FROM LVPLS1/35 AND CONNECT THE SMOKE DAMPER. PROVIDE A FIRE ALARM CONTROL MODULE TO CONTROL THE DAMPER. WIRE THE DAMPER SUCH THAT IT IS POWERED ON. FURNISH DUCT DETECTOR AND PROVIDE DUCT TEST STATION. WIRE TO FIRE ALARM SYSTEM. N 1/8" = 1'-0" 2 PARTIAL THIRD FLOOR PLAN - ELECTRICAL # H M M M S S S D EG-1 LH GFI LS X3 WP TOP OF SHAFT LH LH ODU-1 WP GFI LS 8'-0" AFF C L 8'-0" AFF C L 22 DOAS-1 1 LVPLS/3 LVPLS/26,28,30 1 LVPLS/5 30AF 30AS60AF 60AS 10 e701 6 7 WP 6 e702 GFI WP 3 2 2 BLOCK HEATER AND BATTERY CHARGER LVPH4/5 1 2 3 4 5 6 7 8 10 11 12 14 13 16 A C D E F G H I A.5 B 7.6 B.1 15.5 15.6 H.3 9 RADON FAN. COORDINATE EXACT LOCATION WITH ARCHITECT (TYP) RADON FAN. RADON FAN. RADON FAN. RADON FAN. LVPH4/6 LVPH4/6 LVPH4/6 LVPH4/6 LVPH4/8 LVPH4/8 LVPH4/8 E.10 plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e104 ROOF PLAN -ELECTRICALLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 709 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.22.2019 1/8" = 1'-0" 1 ROOF PLAN - ELECTRICAL e104 ELECTRICAL DRAWING NOTES 1 PROVIDE EXIT SIGN AND CONNECT TO A 20A/1P CIRCUIT BREAKER IN PANEL LVPLS/2 USING 2-#12, 1-#12EG IN 1/2" CONDUIT. LOCK CIRCUIT BREAKER IN ON POSITION. 2 CONNECT LUMINAIRE TO LIFE SAFETY BRANCH CIRCUIT IN PANEL LVPLS, CIRCUIT 4. 3 CONNECT TO FIFTH FLOOR CORRIDOR RECEPTACLE CIRCUIT. # N TV TV IC 3D 3D F F S D PP S S MM S M MS F S 3 3D F F TV TV D S S PP MS M 3D3 IC F M MS TV TV S 3 3D S S F PP F 3D 3D IC F MS M M MS VS S 207 (TYPE 2) 1-BEDROOM APARTMENT 44" GFI TR 48" 44" GFI TR 44" GFI TR 44" GFI TR 44" TR GFI A 44" TR TR TR TR TR TR TR TR TR TR TR TR TR LC202 LC LC LC LA LC LA LA LC LA LB 1 2 2 3 3 EF-1 VRP-12KA 4 5 7AB AB 8 8 9 10 LC202/1LC202/3 LC202/4 LC202/7 LC202/6 LC202/8,10 a,b a 7 15 LF d e d e f f d LA EQEQ EQEQ EQ EQ EQ EQ S LC202/2 F/L b LE LC202/5 2 3 6 LF LC202/9,11 7 8 D E F 7.6 9 A 48" 44" TR 44" TR GFI 44" GFI TR 44" GFI TR 44" GFI TR 44" GFI TR TR TR TR TR TR TR TR TR TR TR TR TR TR LA LBLC LC LC LA LA LA LC LC213 1 2 3 4 5 7 8 9 10 AB 8 AB 3 2 VRP-12KA LC213/4 LC213/5 LC213/6 LC213/8,10 202 (TYPE 4) 1-BEDROOM APARTMENT b,c b LF 6 15 LA EQ EQ EQEQ e e EQ EQ EQEQ EQEQ EQ EQ a a e a LC213/3 LC213/2 f f c LC213/7 LE S EF-1 2 3 LF 7 F/L LC213/1 LC213/9,11 1413 16 G H I 15.5 15.6 H.3 48" TR 44" GFI TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR 44" GFI TR 44" GFI TR 44" GFI TR A 44" TR LA LC LA LB LC LC LA LC LC214 LA 1 2 3 4 5 7 8 9 10 AB AB 8 2 3 LC214/2 LC214/3 LC214/4 LC214/5 LC214/6 LC214/7 LC214/8,10 LC214/9 201 (TYPE 3) 1-BEDROOM APARTMENT LF 7 15 c,d c 44" GFI TR LA 5' - 8 3/32"8' - 0"5' - 9 21/32" 6' - 11 1/2"6' - 8 1/4" EF-1 VRP-12KA LC214/1 a a a b f b f d LE b F/L S 6 LF 2 3 LC214/11,13 LA 11 12 13 F G H I H.3 48" 48" 48" 48" 48" 48" LI ¼" X 2" X 12" GROUND BAR AT 7'-0" AFF 4 e702 5 e702 11 216 I.T. CLOSET 12 LVPH4 13 LVPLS/6 14 PROVIDE WALL MOUNTED DATA EQUIPMENT CABINET ON EACH FLOOR LVPEM/15 LVPEM/16 2 C plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e601 ENLARGED PLANS -ELECTRICALLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 709 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.22.2019 1/4" = 1'-0" 1 ENLARGED UNIT 2 - ELECTRICAL 1/4" = 1'-0" 2 ENLARGED UNIT 3 - ELECTRICAL 1/4" = 1'-0" 3 ENLARGED UNIT 4 - ELECTRICAL e601 ELECTRICAL DRAWING NOTES 1 PROVIDE LOAD CENTER. MOUNT AT 48" AFF TO THE TOP OF THE LOAD CENTER. 2 AT EACH APARTMENT VOICE/DATA OUTLET, PROVIDE (2) CATEGORY 6 VOICE CABLES BACK TO THE APARTMENT MECHANICAL ROOM FOR VOICE/DATA. TERMINATE ON THE WALL MOUNTED PATCH PANEL. PROVIDE ALL TESTING, AND LABELING. PROVIDE COVER PLATE. 3 AT EACH TELEVISION OUTLET, PROVIDE (1) RG6/U CABLE FROM THE OUTLET BOX BACK TO THE SPLITTER LOCATED IN APARTMENT MECHANICAL ROOM. LABEL CABLE. PROVIDE ALL SPLITTERS, TERMINATIONS, AND TESTING. REFER TO CATV RISER DIAGRAM FOR MORE INFORMATION 4 IN EACH APARTMENT MECHANICAL ROOM, PROVIDE 12 PORT PATCH PANEL. PROVIDE (1) CATEGORY 6 CABLE FROM PATCH PANEL, BACK TO ** ROOM 125. TERMINATE THE CABLE AT THE 48 PORT WALL MOUNTED PATCH PANEL FOR VOICE CABLES. PROVIDE ALL TERMINATIONS, TESTING AND LABELING. 5 LOCATION OF SPLITTER IN THE APARTMENT MECHANICAL ROOM, PROVIDED BY SPECTRUM CABLE. PROVIDE RG6/U (MAXIMUM LENGTH OF 150') OR RG11/U (OVER 150' LENGTH) COAXIAL CABLE BACK TO ELECTRIC ROOM 125. LABEL CABLE AT EACH END. TIME WARNER TO PROVIDE ALL TERMINATIONS AND TESTING. 6 PROVIDE 15 CANDELA FIRE ALARM NOTIFICATION APPLIANCE. PREWIRE FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT FROM AOM IN THE CORRIDOR TO JUNCTION BOX FOR FUTURE ADA ADAPTABILITY. REFER TO FIRE ALARM SYSTEM RISER FOR WIRING DETAILS. 7 PROVIDE LOW FREQUENCY, 110 CANDELA FIRE ALARM NOTIFICATION APPLIANCE. PREWIRE FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT FROM AOM IN THE CORRIDOR TO JUNCTION BOX FOR FUTURE ADA ADAPTABILITY. REFER TO FIRE ALARM SYSTEM RISER FOR WIRING DETAILS. 8 PROVIDE 120VAC, MULTIPLE STATION COMBINATION SMOKE DETECTOR, WITH AUDIBLE BASE. CONNECT BRANCH CIRCUIT TO THE LIGHTING CIRCUIT AHEAD OF ALL SWITCHING. PROVIDE WIRING BETWEEN THE DEVICES SUCH THAT IF ONE DEVICE GOES INTO ALARM, ALL AUDIBLE BASES WILL SOUND. 9 PROVIDE TWO SWITCHES TO CONTROL THE HOOD LIGHT AND THE OTHER TO CONTROL THE HOOD EXHAUST FAN. CONNECT THE RANGE HOOD VIA THE KITCHEN RECEPTACLE CIRCUIT. INSTALL IN CABINET VALANCE FACE. PROVIDE STAINLESS STEEL COVER PLATE AND BLACK SWITCHES. IN ADA UNIT, PROVIDE WIRING IN CONDUIT. 10 PROVIDE NEMA 14-50R RECEPTACLE FOR RANGE. PROVIDE 3/C #6 + #10EG TYPE NM CABLE FROM A 50A/2P CIRCUIT BREAKER IN THE APARTMENT PANEL. 11 PROVIDE (2) 4" SLEEVES ABOVE ACCESSIBLE CEILING SPACE. FIRE STOP AS REQUIRED. 12 PROVIDE 4'x8'X3/4" PLYWOOD BACKBOARD AT 6" A.F.F. PAINT WITH 2 COATS FIREPROOF GRAY PAINT. 13 PROVIDE PANEL LVP4 ON FOURTH FLOOR ONLY. 14 PROVIDE 4" CONDUIT BETWEEN EACH FLOOR. 1/4" = 1'-0" 4 ENLARGED IT CLOSET - ELECTRICAL N # PVC CONDUIT THREADED CAP ON ALL SPARES TO COUPLING, PULLBOX, PANEL ECT. PVC TO RIGID ADAPTER PROVIDE ENGRAVED NAMEPLATE ON CONDUITFINISHED FLOOR WRAP ALL JOINTS 100% WATERTIGHT SEAL VAPOR BARRIER TO CONDUIT RIGID HOT DIPPED GALVANIZED CONDUIT BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT SAND BED ENVELOPE AS CALLED FOR ON PLANS. WHERE CONDUIT STUBS UP UNDER FLOOR MOUNTED EQUIPMENT SUCH AS SWITCHGEAR, PROVIDE PVC ELBOWS IN LIEU OF RIGID SHOWN. AT EACH CONDUIT STUB-UP, AFFIX ENGRAVED PLASTIC NAMEPLATE INDICATING CONDUIT NO. OR CIRCUIT IDENTIFICATION. ATTACH WITH NYLON CABLE TIE. NOTES: 2 NO SCALE CONDUIT STUB-UP INSIDE BUILDING DETAIL 1. 2. 1 NO SCALE 12" 6'-0" 1 2 4 5 6 7 3 8 9 1 2 3 4 5 6 7 8 9 CONDUIT RISER AT UTILITY POLE DETAIL NOTES: POLE BY UTILITY COMPANY. TERMINATE RACEWAY AT HEIGHT DICTATED BY UTILITY COMPANY. TERMINATE AND CAP SPARE RACEWAY. MINIMUM 3'-0" BELOW GRADE. (2) 4" PVC, SCHEDULE 40 CONDUITS. SANDBED ENVELOPE, MINIMUM 3" COVER ON ALL SIDES. ENCASEMENT SHALL RUN FROM 6'-0" OFF OF POLE TO RACEWAY TERMINATION AT TRANSFORMER PAD. PVC TO RIGID STEEL CONDUIT ADAPTER. (2) 4" GALVANIZED, RIGID STEEL CONDUITS. 90 x 36" RADIUS SWEEP ELBOWS. NO SCALE 3 GENERAL NOTES: 2' VERTICAL COMMON TRENCH SEPERATION DETAIL COMMON TRENCH 600V SERVICE CABLE IN CONDUIT OR DIRECT BURIED OTHER UTILITIES COMMUNICATIONCATV GAS MIN. 8'12" A. B, NO SEWER/WATER/DRAINAGE/BRANCH CIRCUIT WIRING OR CUSTOMER FUEL LINE IN COMMON TRENCH. IF OTHER UTILITIES, SUCH AS CUSTOMER SEWER, WATER, DRAINAGE, BRANCH CIRCUIT WIRING, OR CUSTOMER FUEL LINE, CROSS THE ELECTRIC OR COMMON TRENCH, A MINIMUM 2' OF VERTICAL SEPARATION MUST BE MAINTAINED. 12" 4 NO SCALE DIRECT BURIED CONDUIT DETAIL ONE DUCT 40" MIN. GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE 5 NO SCALE DIRECT BURIED CONDUIT DETAIL TWO DUCTS 40" MIN. 7 1/2" GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE 7 1/2" 40" MIN. 7 1/2" 6 NO SCALE DIRECT BURIED CONDUIT DETAIL THREE DUCTS GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE 7 NO SCALE DIRECT BURIED CONDUIT DETAIL FOUR DUCTS 7 1/2" 40" MIN. 7 1/2" GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT PROVIDE SPACERS TO ENSURE EVENINSTALLATION. 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE 11 PROTECTIVE BOLLARD DETAIL SUBGRADE PAINT YELLOW PAVEMENT OR GRADE NO SCALE 3,000 PSI CONCRETE CONCRETE CAP - ROUND OFF TOP 6" DIAMETER SCHEDULE 40 GALVANIZED PIPE FILLED WITH 3,000 PSI CONCRETE 1/2" EXPANSION JOINT FILLER WITH SEAL 4'-0" MIN. 4'-0" MIN. 6" 6"6" 6"2' -0" 2'-0" WP GFI PROVIDE RECEPTACLE AT GENERATOR 4-#10, 1-#10EG, 1" C 28 26 30 TO LVPEM 200A/3P (3) 20A/1P 10 NO SCALE EMERGENCY GENERATOR SCHEMATIC WIRING DIAGRAM JJ DIGITAL CONTROL PANEL (FURNISHED WITH GENERATOR) CONNECT BATTERY CHARGER 2-#12, 1-#12EG, 1/2"C 2-#12, 1-#12EG, 1/2"C (10) #18 SHIELDED TWISTED PAIR IN 1"C OR AS REQUIRED BY MANUFACTURER LVPLS/26 (20A/1P C.B., BLOCK HEATER) LVPLS/28 (20A/1P C.B., BATTERY CHARGER) LVPLS/30 (20A/1P C.B., GFI RECEPTACLE) INSTALL ANNUNCIATOR PANEL FURNISHED WITH GENERATOR. INSTALL IN RECEPTION OFFICE 003 ATS-EM 208Y/120V 200A/3P TO TELEPHONE TERMINAL BLOCK CONNECT BLOCK HEATER (1) #18 SHIELDED TWISTED PAIR IN 1/2 "C FOR GENERATOR START SIGNAL (2) #22 AWG TWISTED PAIR, 3/4 "C (2) ENCLOSED CIRCUIT BREAKERS IN GENERATOR ENCLOSURE EMERGENCY GENERATOR 60KW/75KVA 208Y/120V NATURAL GAS LOCATED ON ROOF PROVIDE EMERGENCY STOP BREAKGLASS PUSHBUTTON. INSTALL OUTSIDE OF GENERATOR ROOM OR EXTERNAL TO THE WEATHERPROOF ENCLOSURE 2-#14, 1/2"C TO LVPLS ATS-LS 208Y/120V 60A/3P 60A/3P 4-#4/0, 1-#4EG IN 4" C 4-#4, 1-#8EG IN 4"C TOP VIEW SIDE VIEW 9 CONCRETE EQUIPMENT PAD DETAIL 6" x 6" 10/10 WIRE MESH FINISH GRADE NO SCALE PAD SHOULD BE A MINIMUM OF 6" LARGER THAN THE EQUIPMENT ENCLOSURE ON ALL SIDES 6" x 6" 10/10 WELDED WIRE MESH PROVIDE 1", 45 DEGREE CHAMFER ON ALL SIDES 3000 PSI CONCRETE EQUIPMENT PAD 4" 6" 12 NO SCALE 6" 42" 2" 30" 36" CHAMFER ALL EDGES ELECTRICAL CONDUIT PER SITE PLAN #4 REBARS AT EACH CORNER VERTICAL #3 TIES AT 12" O.C. HORIZONTAL 12" ROUND CONCRETE BASE BY E.C. VERIFY WITH BOLLARD MFGR. FINISHED GRADE BOLLARD WITH LIGHT BASE DETAIL 8 NO SCALE DIRECT BURIED CONDUIT DETAIL SIX DUCTS 40" MIN. 7 1/2" 7 1/2" 7 1/2" GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT PROVIDE SPACERS TO ENSURE EVENINSTALLATION. 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e701 ELECTRICAL DETAILSLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 709 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.22.2019 1 NO SCALE VAULT TYPE TRANSFORMER PAD DETAIL #2 CRUSHED STONE, 8" DEEP 10'-0" MINIMUM TO BUILDING TRANSFORMER PAD (72"x72") 20"x40" OPENING 5/8"x8' LONG GROUND ROD (TYP OF 4) 2-250 KCM BARE COPPER GROUND WIRE AT 36" BELOW GRADE STANDARD COVER RG&E STANDARD MC-101M OR EQUAL BY QUAZITE RG&E STANDARD MC-100 OR EQUAL BY QUAZITE 5/8"x8' GROUND ROD 6" 6" 9" 4'-0" 2'-2" 6'-0" 6'-0" 6" 1'-4" 3'-4" 1'-8" 1'-0" 18" NOTES: VAULT TYPE PADS SHALL BE PRE-CAST CONCRETE OR PRECAST POLYMER CONCRETE, AS PERMITTED BY THE UTILITY. PROVIDE (1) 5/8 " X 8' COPPER GROUND ROD IN CORNER OF VAULT.PROVIDE #2 BARE COPPER GROUND RING TO BE INSTALLED 3' FROM THE VAULT AND BURIED A MINIMUM OF 36" DEEP. ATTACH BOTH ENDS OF THE GROUND RING TO THE GROUND ROD. PROVIDE A MINUMUM OF 3" OF #2 CRUSHED STONE BASE. INSTALL PER UTILITY SPECIFICATIONS. COORDINATE INSTALLATION WITH UTILITY. 1. 2. 3. 4. 5. N L1 L2 L3 GROUND BUS NEUTRAL BUS 2 NO SCALE SERVICE ENTRANCE GROUNDING DETAIL GROUNDING ELECTRODE SYSTEM NOTES: SERVICE ENTRANCE DISCONNECTING MEANS GROUNDED CONDUCTOR SERVICE ENTRANCE CONDUCTORS PROVIDE ELECTRODE CONDUCTOR. PROVIDE INSULATED COPPER CONDUCTOR PER SPECIFICATIONS. IF NO SIZE SPECIFIED, PROVIDE INSULATED COPPER CONDUCTOR SIZED PER N.E.C. TABLE 250-94. INSTALL IN RIGID, SCHEDULE 40, PVC RACEWAY. METAL UNDERGROUND WATER PIPE IN DIRECT CONTACT WITH EARTH FOR 10 FEET OR MORE. SHALL BE SUPPLEMENTED BY ITEMS 3 AND 4. BUILDING STRUCTURAL STEEL. MADE GROUNDING ELECTRODE. REFER TO "MADE GROUNDING ELECTRODE-GROUND GRID" DETAIL AND SPECIFICATIONS. MAIN BONDING CONDUCTOR. PROVIDE INSULATED COPPER CONDUCTOR SIZED PER N.E.C. ARTICLE 250-94. BOND GROUND BUS TO EQUIPMENT ENCLOSURE WITH BARE COPPER BONDING JUMPER SIZED PER N.E.C. ARTICLE 250-79. WATER MAIN FOOTER STEEL GROUND STEEL BUILDING STEEL 1 2 3 4 5 6 1 6 5 4 NO SCALE GROUND BAR ON WALL TWO HOLE COMPRESSION LUG GROUND WIRES BY EQUIPMENT VENDOR GROUND BAR CONNECTION DETAIL DRAWING NOTES: 5 NO SCALE GROUND BAR DETAIL 2" 2" 1" 7/16" DIA. COPPER GROUND BAR, 1/4"x4"x12" (MAIN SERVER RM) OR 1/4"x2"x12" (IT RMS), NEWTON INSTRUMENT CO. OR EQUAL. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. INSULATORS, NEWTON INSTRUMENT CO. CAT. NO. 3061-4 OR EQUAL. 5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. CAT. NO. 3015-8 OR EQUAL. WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT. NO. A-6056 OR EQUAL. 5/8-11 x 1" H.H.C.S. BOLTS, NEWTON INSTRUMENT CO. CAT. NO. 3012-1 OR EQUAL. LONG BARREL DOUBLE HOLE COMPRESSION LUG 3 4 5 1 2 6 1 2 3 4 5 6 GENERAL NOTES: 6 NO SCALE ROOF RECEPTACLE STUB-UP DETAIL GALVANIZED CONDUIT (SIZE AS REQUIRED) WEATHERPROOF DUPLEX RECEPTACLE WITH SPRING-LOADED CAP. KEY LOCKABLE, WEATHERPROOF ENCLOSURE SHALL BE MARKED "SUITABLE FOR WET LOCATIONS WHILE IN-USE." SEALTIGHT CONNECTOR FLASH AND SEAL ROOF PENETRATION AS REQUIRED TO MAINTAIN ANY ROOF WARRANTEE. PROVIDE THE SERVICES OF A QUALIFIED ROOFING CONTRACTOR. FINISHED FLOOR CEILING AAB12 AAB13 4" MINIMUM 7 NO SCALE FLUSH VOICE/DATA OUTLET INSTALLATION DETAIL PROVIDE 1/2" CONDUIT INSIDE NEW WALL PROVIDE 4 11/16" SQUARE x 2 1/8" DEEP BACKBOX WITH SINGLE GANG MUD RING PROVIDE 2-GANG BACKBOX WITH DOUBLE DUPLEX RECEPTACLE, FLUSH MOUNTED PROVIDE 1" CONDUIT WITH PULLSTRING TO CEILING SPACE WALL CAT 5 SPARE SPARECAT 5 CASE A CASE B CASE C NO SCALE 8 TYPICAL CABLE HANGER DETAIL BACKBONE UTP COAX AND FIBER COAX AND FIBER BACKBONE UTP OPTICAL FIBER AND COAX BACKBONE UTP (WHERE APPLICABLE) CAT 5 CABLES (PROVIDE HANGER SIZE AND QUANTITY AS REQUIRED) SPARE HANGER (PROVIDE ONE PER RUN) NOTE: PROVIDE HANGERS IN CONFIGURATIONS OR COMBINATIONS OF CONFIGURATIONS SHOWN AS REQUIRED TO SUIT SITE CONDITIONS IN ALL CASES PROVIDE A SPARE HANGER RUN FOR FUTURE CABLING. 1. FT PANELBOARD DISCONNECT THERMOSTAT LIGHT SWITCH CARD ACCESS VOICE/DATA OUTLET DUPLEX RECEPTACLE 6'-8" 6'-0" 5'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 1'-6" 1'-6" 1'-6" 4'-0" NO SCALE 9 TYPICAL DEVICE MOUNTING ELEVATIONS NOTES: FIRE ALARM AUDIO/VISUAL AND VISUAL DEVICE IN LOCATIONS WHERE SIMILAR DEVICES ARE MOUNTED AT THE SAME HEIGHT, DEVICES SHALL BE PROPERLY "GANGED" AND SHALL HAVE A SINGLE COVER PLATE. IN LOCATIONS WHERE DIFFERENT DEVICES ARE MOUNTED AT DIFFERENT HEIGHTS WITHIN FOUR FEET OF ONE ANOTHER, DEVICES SHALL BE MOUNTED SUCH THAT THEY HAVE A COMMON CENTERLINE. IF THERE ARE THREE OR MORE DEVICES, THE CONTRACTOR SHALL REQUEST A DETAIL FROM THE ARCHITECT. 1. 2. FIRE ALARM PULL STATION WALL MOUNTED TELEPHONE DUPLEX RECEPTACLE MECH. ROOM, GARAGES DESK TOP TELEPHONE/ CATV OUTLET FINISHED FLOOR 4'-0" APARTMENT LOAD CENTER 3 NO SCALE GASKETED HAND HOLE 1" x 45° CHAMFER #3 TIES 12" ON CENTER #6 BARE COPPER GRD. WIRE MECH. COMPR. CONNECTION PVC SCHEDULE 80 CONDUIT GALVANIZED CONDUIT "ELL." (4) #8 VERTICAL REINFORCEMENT BAR 4000 P.S.I. CONCRETE 5'-0" MIN. DOWN TO SOLID BEARING 1. 2. FINISHED GRADE (PAVEMENT) BOLT OR MECH. COMPR. GROUND WIRE TO POLE PROVIDE IN-LINE BALLAST FUSES. PROVIDE (2) BUSSMANN "TRON" WEATHERPROOF FUSE HOLDERS, CAT# HEB-AB WITH (2) 10A "KTK" FUSES FOR EACH LUMINAIRE. (4)-36" x 1" DIA. ANCHOR BOLTS GALVANIZED STEEL TO PVC CONDUIT CONNECTOR ROUND FORMED CONCRETE BASE 24" DIA. CONCRETE BASE TOP OF POLE BASE TO BE MEASURED FROM ADJACENT PAVEMENT GRADE. CENTER LIGHT POLES IN ISLANDS. OUTSIDE DIMENSIONS OF ISLANDS ARE 9'-0" X 36'-0". NOTES: 5/8" DIA. x 8' COPPERWELD GROUND ROD (LIGHTNING PROTECTION) LIGHT POLE BASE DETAIL POLE BASE SCHEDULE POLE HEIGHT BASE DIAMETER 39' AND UP 30" DIAMETER 30' - 38' 24" DIAMETER 20' - 29' 18" DIAMETER 15" DIAMETER19' AND BELOW 6" IN LAWN 2' IN PAVEMENT 16'-0" plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e702 ELECTRICAL DETAILSLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 709 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.22.2019 F F F F FFFF S H EC H F TS S H EC S F TS F F H AOM AOM F F COMMON AREA DEVICES ELEV. LOBBY 120V ELEV. LOBBY FACP/ FARPS DIGITAL COMMUNICATOR COMMON AREA DEVICES TWO TELEPHONE LINES S ST AUX AUX AUX 24 VOLT DC GROUND FLOOR SLC RESIDENT UNITS TYP 2ND - 5TH FLOORS SLC RESIDENT ROOMS TYP 2ND - 5TH FLOORS SLC COMMON AREAS GROUND FLOOR SLC COMMON AREAS TYP 2ND - 5TH FLOORS NAC COMMON AREAS GROUND FLOOR NAC COMMON AREAS TO NEXT APT. CO SENSOR, ICP OR END OF LINE 24 VOLT DC TO NEXT APT. CO SENSOR, ICP OR END OF LINE TO NEXT NOTIFICATION DEVICE OR END OF LINE TO NEXT NOTIFICATION DEVICE OR END OF LINE TYPICAL ACCESSABLE APARTMENT CONFIGURATION TYPICAL ACCESSABLE APARTMENT CONFIGURATION 120V ST AUX ELEV. MECH RM SHUNT TRIP ELEV. PIT SHUNT TRIP TO NEXT ADDRESSSABLE DEVICE/MODULE TO NEXT ADDRESSSABLE DEVICE/MODULE LVPLS/1 NO SCALE 1 FIRE ALARM RISER DIAGRAM DRAWING NOTES: INSTALL ICP AND AUDIO/VISUAL FIRE ALARM DEVICES IN ACCESSIBLE UNIT ONLY. ALL OTHER UNITS SHALL BE PREWIRED AS INDICATED SUCH THAT FUTURE ADDITION OF REQUIRED DEVICES FOR ACCESSIBLE UNITS IS AVAILABLE. THIS DRAWING IS DIAGRAMMATIC ONLY. FUNCTIONS SHOWN AS HARDWIRED MAY BE ACCOMPLISHED THROUGH THE USE OF INTELLIGENT DEVICES AND SOFTWARE. 1. NOTES: 1 11 1 11 1 F F LOW FREQUENCY LOW FREQUENCY REMOTE ANNUNCIATOR S TV TV T A T TV TV TV T T TV NO SCALE CATV SYSTEM RISER DIAGRAM 5 RG6/U DROP CABLE (TYPICAL) 8-PORT DIRECTIONAL TAP (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) WALL MOUNT TAPS IN APARTMENT MECHANICAL CLOSET 2ND FLOOR CATV SPLITTER BY CATV COMPANY RG11/U BACKBONE CABLE GROUND FLOOR WALL MOUNTED BROADBAND AMPLIFIER BY CATV COMPANY 4" PVC-80, DIRECT BURIED FOR CATV. REFER TO SITE PLAN FOR MORE INFORMATION RG6/U DROP CABLE (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) TELE/DATA LOCATED IN SERVER 008 TYPICAL APARTMENT TYPICAL APARTMENT COMMUNITY ROOM LOUNGE BR1LR BR1LR S S TV TV T T TV WALL MOUNT TAPS IN APARTMENT MECHANICAL CLOSET RG6/U DROP CABLE (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) TYPICAL APARTMENT LOUNGEBR1LR S S 3RD FLOOR TV TV T T TV WALL MOUNT TAPS IN APARTMENT MECHANICAL CLOSET RG6/U DROP CABLE (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) TYPICAL APARTMENT LOUNGEBR1LR 4TH FLOOR TV TV T T TV WALL MOUNT TAPS IN APARTMENT MECHANICAL CLOSET RG6/U DROP CABLE (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) TYPICAL APARTMENT LOUNGEBR1LR 5TH FLOOR NO SCALE 2 INTERCOM WIRING DIAGRAM 120 VOLTS ENTRY PANEL AUDIO LINE, 485 BUS AND LOW VOLTAGE POWER TRANSFORMER TWISTED PAIR MASTER STATION LOCATED IN RECEPTION/SECURITY OFFICE ENTRY PANEL LOCATED AT FRONT DOOR DOOR STRIKE SUITE STATION SUITE STATION SUITE STATION MASTER STATION NO SCALE 3 LIGHTING CONTROL PANEL WIRING DIAGRAM CATEGORY 5 CABLE (TYPICAL) BLDG MTD SIGN LIGHTING CONTROL PANEL ANALOG PHONE LINE LVPLS/10 SITE POLE LTG LCD BLUE BOX LT PANEL WITH INTEGRAL TIME CLOCK LCD PHOTOCELL CONTROL OUTPUT COMMON +24V dc POWER PACK LINE NEUTRAL 120V CONTROL OUTPUT COMMON +24V dc CONTROL OUTPUT COMMON +24V dc LOAD-a LOAD-b NO SCALE OCCUPANCY SENSOR DETAIL 4 CEILING MOUNTED OCCUPANCY SENSOR ADDITIONAL CEILING MOUNTED OCCUPANCY SENSOR AS REQUIRED 3-WAY SWITCH a WALL SWITCH b PROVIDE 3-WAY AND/OR DUAL LEVEL SWITCHING AS CALLED FOR ON PLANS 3-WAY SWITCH WALL SWITCH ADDITIONAL CEILING MOUNTED OCCUPANCY SENSOR AS REQUIRED plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e703 ELECTRICAL WIRING DIAGRAMSLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 709 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.22.2019 NO SCALE ELEVATOR POWER WIRING DIAGRAM 3 S S SH SS M N ELEVATOR SHAFT SMOKE HATCH TO ELEVATOR CONTROLLER GROUND FLOOR LOBBY SMOKE DETECTOR ELEVATOR CONTROLLER ELEVATOR WIRING BY ELEVATOR SUPPLIER TO NEAREST 120V RECEPTACLE CIRCUIT ST HH ELEVATOR SHAFT HEAT DETECTOR (BOTTOM) ELEVATOR SHAFT HEAT DETECTOR (TOP) ST 60A/3P 2ND FLOOR LOBBY SMOKE DETECTOR ELEVATOR SHAFT SMOKE DETECTOR LVPHP 20A/1P NOTES: 1. THIS DRAWING IS DIAGRAMMATIC ONLY. FUNCTIONS SHOWN AS HARDWIRED MAY BE ACCOMPLISHED THROUGH THE USE OF INTELLIGENT DEVICES AND SOFTWARE. TO ELEVATOR CONTROLLER TO ELEVATOR CONTROLLER S 3RD FLOOR LOBBY SMOKE DETECTOR GROUND FLOOR LOBBY SMOKE DETECTOR ELEVATOR CONTROLLER SHUNT TRIP CIRCUIT BREAKER AUXILIARY CONTACT 60A/3P FUSED SWITCH WITH 60 AMP FUSES AND ELECTRICAL INTERLOCK KIT. LOCATE AS SHOWN ON PLANS. PROVIDE 2-#12 IN ½"C TO ELEVATOR CONTROLLER 60A FUSIBLE DISCONNECT SWITCH ELECTRICAL INTERLOCK KIT 60A NON-FUSIBLE ELECTRICAL INTERLOCK KIT 2-#12 IN ½"C 3-#4, 1-#4EG IN 1 ¼"C 60A NON FUSED SWITCH WITH ELECTRICAL INTERLOCK KIT. LOCATE AT TOP OF ELEVATOR SHAFT. PROVIDE 2-#12 IN ½"C TO ELEVATOR CONTROLLER 60A/3P SHUNT TRIP CIRCUIT BREAKER WITH AUXILIARY CONTACT. PROVIDE 2-#12 IN ½"C TO ELEVATOR CONTROLLER S 4TH FLOOR LOBBY SMOKE DETECTOR S 5TH FLOOR LOBBY SMOKE DETECTOR 13 14 15 16121110987654321 24 1917 18 21 20 22 23 25 26 27 28 29 30 40 353231 33 34 37 36 38 39 44 41 42 43 46 45 47 48 13 14 15 16121110987654321 24 1917 18 21 20 22 23 25 26 27 28 29 30 40 353231 33 34 37 36 38 39 44 41 42 43 46 45 47 48 2 4 1 1 1 3 3 1 2 3 4 5 5 WALL CABINET 48 PORT FIBER HORIZONTAL WIRE MANAGEMENT WALL EQUIPMENT RACK 48 PORT CATEGORY 6 PATCH PANEL 48 PORT OPTICAL FIBER PATCH PANEL DATA A DATA B NO SCALE TELE/DATA RACK ELEVATION 1 (6) OUTLET SURGE PROTECTED POWER STRIP RACK/CABINET ELEVATIONS EQUIPMENT SCHEDULE SERVER ROOM 13 14 15 16121110987654321 24 1917 18 21 20 22 23 25 26 27 28 29 30 40 353231 33 34 37 36 38 39 44 41 42 43 46 45 47 48 13 14 15 16121110987654321 24 1917 18 21 20 22 23 25 26 27 28 29 30 40 353231 33 34 37 36 38 39 44 41 42 43 46 45 47 48 2 6 1 1 1 3 3 5 WALL CABINET 12 PORT FIBER DATA A DATA B TYP 2 - 5 IT ROOM 6 12 PORT OPTICAL FIBER PATCH PANEL GROUND FLOOR 0' - 0" HOUSE AND HORIZON METERS 200A METER CHANNEL, 3 PH, 4 WIRE 1600A/3P MAIN CIRCUIT BREAKER 208Y/120 VOLTS, 3 PHASE, 4 WIRE INPUT, SERVICE ENTRANCE RATED PROVIDE 100 AMPERE RATED ALUMINUM TYPE SE CABLE FROM EACH METER CHANNEL TO THE RESPECTIVE APARTMENT LOAD CENTER. VERIFY CABLE ROUTING IN THE FIELD. COORDINATE SERVICE ENTRANCE WITH NYSEG FIVE-CHANNEL METER SECTION WITH 100A/2P MAIN CIRCUIT BREAKERS (25 METERS TOTAL) FIVE-CHANNEL METER SECTION WITH 100A/2P MAIN CIRCUIT BREAKERS (35 METERS TOTAL) 5 2 NO SCALE FIBER OPTIC WIRING DIAGRAM 6 STRAND MULTIMODE FIBER 13141516 12 11 10 9 8 7 6 5 4 3 2 124 19 17 1821 202223 25262728293040 35 32 31 333437 36383944 41424346 454748 48 PORT FIBER OPTIC PATCH PANEL 13141516 12 11 10 9 8 7 6 5 4 3 2 124 19 17 1821 202223 25262728293040 35 32 31 333437 36383944 41424346 454748 12 PORT FIBER OPTIC PATCH PANEL 2ND FLOOR IT RM 1ST FLOOR SERVER RM 008 13141516 12 11 10 9 8 7 6 5 4 3 2 124 19 17 1821 202223 25262728293040 35 32 31 333437 36383944 41424346 454748 12 PORT FIBER OPTIC PATCH PANEL 13141516 12 11 10 9 8 7 6 5 4 3 2 124 19 17 1821 202223 25262728293040 35 32 31 333437 36383944 41424346 454748 12 PORT FIBER OPTIC PATCH PANEL 13141516 12 11 10 9 8 7 6 5 4 3 2 124 19 17 1821 202223 25262728293040 35 32 31 333437 36383944 41424346 454748 12 PORT FIBER OPTIC PATCH PANEL 3RD FLOOR IT RM 4TH FLOOR IT RM 5TH FLOOR IT RM /// /// /// /// /// /// /// /// /// /// /// /// // Communication Line // // // // // // // // // // // // // // // # Note : Power wiring, breaker size, and disconnects should follow local code and NEC. Multi-frame outdoor units require a separate power connection for each frame. Refer to the most up-to-date submittal sheets for applicable electrical data. MCA : 63.2 MOP : 80 V,Hz : 3Phase/208~230V/60Hz ARUM241BTE5 Combi. : ARUM241BTE5 Additional Refrigerant : 42.43 lbs PRHR023A (BCC-4) RLA : 0.06 ARNU183M2A4 (#FCU-12) PREMTBVC0 RLA : 2.30 ARNU243M2A4 (#FCU-10) PREMTBVC0 RLA : 2.30 PRHR023A (BCC-3) RLA : 0.06 ARNU183M2A4 (#FCU-09) PREMTBVC0 RLA : 2.30 ARNU183M2A4 (#FCU-11) PREMTBVC0 RLA : 2.30 PRHR043A (BCC-2) RLA : 0.06 ARNU073M2A4 (#FCU-01) PREMTBVC0 RLA : 2.30 ARNU123M2A4 (#FCU-02) PREMTBVC0 RLA : 2.30 ARNU073M2A4 (#FCU-03) PREMTBVC0 RLA : 2.30 ARNU423M2A4 (#FCU-05) PREMTBVC0 RLA : 2.30 PRHR043A (BCC-1) RLA : 0.06 ARNU243M2A4 (#FCU-06) PREMTBVC0 RLA : 2.30 ARNU183M2A4 (#FCU-04) PREMTBVC0 RLA : 2.30 ARNU183M2A4 (#FCU-07) PREMTBVC0 RLA : 2.30 ARNU543M3A4 (#FCU-08) PREMTBVC0 RLA : 2.50 Total RLA : 28.28 BY EC BY MC plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e704 ELECTRICAL WIRING DIAGRAMSLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 709 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.22.2019 1/4" = 1'-0" 4 ELECTRIC SERVICE ELEVATION 1/8" = 1'-0" 5 MULTI V5_DIAGRAM - ELECTRICAL MOTOR RATED SWITCH MANUAL MOTOR STARTER MANUAL MOTOR STARTER WITH RELAY MAGNETIC STARTER COMBINATION MAGNETIC STARTER VARIABLE FREQUENCY DRIVE COMBINATION TWO SPEED MAGNETIC STARTER COMBINATION REDUCED VOLTAGE MAGNETIC STARTER DUPLEX CONTROLLER WITH ALTERNATION CIRCUIT PACKAGED CONTROL UNIT H-O-A SELECTOR SWITCH IN COVER PILOT LIGHT IN COVER REMOTE START-STOP PUSHBUTTONS FIRE ALARM FAN SHUTDOWN LINE-VOLTAGE THERMOSTAT MOTOR STARTER/CONTROLLER NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. PROVIDE 120 VOLT CIRCUIT FROM LVPH1 AND CONNECT AQUASTAT AND TIME SWITCH. CONNECT VIA WALL MOUNTED OCCUPANCY SENSOR SUCH THAT WHEN OCCUPANCY IS SENSED, FAN TURNS ON. DUCT SMOKE DETECTOR TO BE FURNISHED BY ELECTRICAL CONTRACTOR, INSTALLED BY HVAC CONTRACTOR AND WIRED BY ELECTRICAL CONTRACTOR. MECHANICAL EQUIPMENT IS NOT SHOWN ON PLANS. 2ND FLOOR LOCATION IS TYPICAL FOR FLOORS 3 THROUGH 5. REFER TO PARTIAL THIRD FLOOR PLAN FOR LOCATION OF BCC-4 ON FIFTH FLOOR. REFER TO DETAIL 3/e704. PROVIDE BRANCH CIRCUIT TO HPU-1 THEN WIRE FROM HPU-1 TO IFCU-1. PROVIDE MOTOR RATED SWITCH AT EACH UNIT. NOTES: 1. 2. 3. 4. 5. 6. 7. NO SCALE AREA OF RESCUE RISER DIAGRAM 1 plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e801 ELECTRICAL SCHEDULESLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.22.2019 LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION LUMENS LAMP VOLTAGE DESIGN MAKE ACCEPTABLE MANUFACTURERMANUFACTURER MODEL NO. EM1 WALL MOUNTED, DECORATIVE, LED TWO-HEAD EMERGENCY BATTERY PACK WITH SELF DIAGNOSTICS AND TESTING 1300 (2) 6 WATT LED 120 EVENLIGHT LIGHTING TEBL6W-SD APPROVED EQUAL LA 16" DIAMETER SURFACE MOUNTED DECORATIVE LED LUMINAIRE WITH FROSTED ACRYLIC GLASS LENS AND FINISH COLOR BY ARCHITECT. 2000 28 WATT LED, 3000K 120 ROYAL PACIFIC LIGHTING 4327D-30-BN-3K APPROVED EQUAL LB 26" X 5" OVER MIRROR LED LUMINAIRE WITH MATTE WHITE DIFFUSER AND SATIN NICKEL FINISH 1625 13 WATT LED, 3000K 120 OXYGEN LIGHTING 3-5134-24 APPROVED EQUAL LC 2' SURFACE MOUNTED LED LUMINAIRE WITH ACRYLIC LENS AND WHITE HOUSING. 2200 18 WATT LED, 3000K 120 METALUX LIGHTING 2SNLED LED5 LN22 UNV LP830 CD1 APPROVED EQUAL LE 24" LONG UNDER CABINET LED LUMINAIRE WITH ACRYLIC LENS, WHITE HOUSING AND SELECTABLE COLOR TEMPERATURE. PROVIDE ALL REQUIRED MOUNTING HARDWARE. 627 11.1 WATT LED, 120 HALO LIGHTING HU30 SCT 24 P APPROVED EQUAL LG 2' X 2', RECESSED VOLUMETRIC LED TROFFER WITH 3400 LUMENS, SMOOTH ACRYLIC DIFFUSER, SUITABLE FOR GRID INSTALLATION 3400 25.8 WATT LED, 3500K 120 METALUX LIGHTING 22CZ2-34HE-S-UNV-L835-C D1 APPROVED EQUAL LH 4', WALL MOUNTED LED LUMINAIRE WITH FROSTED ACRYLIC LENS, WHITE HOUSING, BI LEVEL DIMMING, AND INTEGRAL OCCUPANCY SENSOR. 3696 30 WATT LED, 3500K 120 INDUSTRIAL LIGHTING PRODUCTS CV4 30WLED UNIV 35 FRAL WHP USBD/HL APPROVED EQUAL LI 4', WALL MOUNTED LED LUMINAIRE WITH SQUARE SEMI FROST ACRYLIC LENS AND WHITE HOUSING 4600 35 WATT LED, 3500K 120 METALUX LIGHTING 4SNLED LED5 SLN46SL UNV L835 CD1 APPROVED EQUAL LJ 12' LINEAR PENDANT LED LUMINAIRE WITH LOW PROFILE, MICROGLOW LENS, AND COLOR BY ARCHITECT. VERIFY HEIGHT ABOVE FLOOR WITH ARCHITECT. 1000LM/FT 108 WATT LED, 3500K 120 FOCAL POINT LIGHTING FTWLS-MG-1000LF-35K-1C -UNV-LD1-J48-DC-**-12' APPROVED EQUAL LK 4" X 4' LINEAR RECESSED LED LUMINAIRE WITH FLUSH SATIN LENS AND SUITABLE FOR INSTALLATION IN WOOD CEILING. COORDINATE TRIM WITH ARCHITECT. 3500 43 WATT LED, 3500K 120 FOCAL POINT LIGHTING FSM4L-FL-875LF-35K-1C-U NV-LD1-TFW-XX-4' APPROVED EQUAL LL 2' X 4', RECESSED VOLUMETRIC LED TROFFER WITH 5500 LUMENS, SMOOTH ACRYLIC DIFFUSER, SUITABLE FOR GRID INSTALLATION 5500 43.5 WATT LED, 3500K 120 METALUX LIGHTING 24CZ2-55HE-S-UNV-L835-C D-1 APPROVED EQUAL LM 2' X 4', RECESSED VOLUMETRIC LED TROFFER WITH 6500 LUMENS, SMOOTH ACRYLIC DIFFUSER, SUITABLE FOR GRID INSTALLATION 6500 48.9 WATT LED, 3500K 120 METALUX LIGHTING 24CZ2-65HE-S-UNV-L835-C D-1 APPROVED EQUAL LN 2' X 4', RECESSED VOLUMETRIC LED TROFFER WITH 7000 LUMENS, SMOOTH ACRYLIC DIFFUSER, SUITABLE FOR GRID INSTALLATION 7000 51 WATT LED, 3500K 120 METALUX LIGHTING 24CZ2-70HE-S-UNV-L835-C D-1 APPROVED EQUAL LO EXTERIOR WALL MOUNTED LED LUMINAIRE WITH UP AND DOWNLIGHT DISTRIBUTION, GLASS DIFFUSER, AND COLOR BY ARCHITECT 22 WATT LED, 4000K 120 PERFORMANCE IN LIGHTING USA QUASAR 20 DOUBLE TECH 22W 4000K 0-10V ** APPROVED EQUAL LP 4IN SQUARE LED DOWNLIGHT WITH 1500 LUMENS, HAZE REFLECTOR AND SUITABLE FOR GRID OR DRYWALL INSTALLATION. 1500 13.4 WALL LED, 3500K 120 HALO LIGHTING PRS4FS15D010-SM4128FS44SMDHTIR4SMD APPROVED EQUAL LQ 6IN SQUARE LED DOWNLIGHT WITH 1500 LUMENS, HAZE REFLECTOR, IC RATED, AND 1500 13.4 WATT LED, 4000K 120 HALO LIGHTING PRS615-D010-SM6128FS-6 1SMDHTIR6SMD APPROVED EQUAL LS EXTERIOR WALL MOUNTED LED LUMINAIRE WITH SLIM, LOW PROFILE, AND INTEGRAL PHOTOCELL 4000 38 WATT LED, 4000K 120 LUMARK LIGHTING XTOR4B-W-**-PC1 APPROVED EQUAL LT 39 3/8" HIGH LED BOLLARD WITH SYMMETRICAL, 360 DEGREE DISTRIBUTION, AND FINISH COLOR BY ARCHITECT. 627 18.4 WATT LED, 4000K 208 BEGA LIGHTING 99570-K4-** APPROVED EQUAL LU SINGLE HEAD LED POLE MOUNTED LUMINAIRE WITH TYPE III DISTRIBUTION ON 16' SQUARE STEEL POLE. FINISH COLOR BY ARCHITECT. 5610 55 WATT LED, 4000K 208 BEACON LIGHTING VPS/24NB-55/4K/T3/UNV/ RA/** APPROVED EQUAL X1 SINGLE FACED UNIVERSAL MOUNT LED EXIT SIGN WITH WHITE THERMOPLASTIC HOUSING, GREEN LETTERS, AND REMOVABLE CHEVRONS - 2 WATT LED 120 EVENLIGHT LIGHTING TLX AC GU W APPROVED EQUAL X2 DUAL FACED UNIVERSAL MOUNT LED EXIT SIGN WITH WHITE THERMOPLASTIC HOUSING, GREEN LETTERS, AND REMOVABLE CHEVRONS - 2 WATT LED 120 EVENLIGHT LIGHTING TLX AC GU W APPROVED EQUAL X3 SINGLE FACED UNIVERSAL MOUNT LED EXIT SIGN WITH WHITE THERMOPLASTIC HOUSING, GREEN LETTERS, AND REMOVABLE CHEVRONS. SUITABLE FOR WET LOCATION - 2 WATT LED 120 EVENLIGHT LIGHTING TWL AC G 1U W CW APPROVED EQUAL ELECTRIC EQUIPMENT SCHEDULE ITEM NO. NAME ROOM LOCATION HP KW PH VOLTS PANEL CIRCUIT NUMBER CIRCUIT BREAKER WIRING FROM PANEL TO CONTROL UNIT WIRING FROM CONTROL UNIT TO EQUIPMENT DISCONNECT SWITCH DISCONNECT SWITCH MOTOR STARTER/ CONTROLLER NOTES CONTROLLER LOCATION NEMA RATING NOTESSWITCH AMPS FUSE SIZE 1 ELEV-1 ELEVATOR SHAFT 3 208 LVPEM 38,40,42 60A/3P SHUNT TRIP 3-#6, 1-#10EG IN 1”C 3-#6, 1-#10EG IN 1”C 60 60 10 AU 1 6 2 HW-3 MECH AND ELEC 010 0.6 1 120 LVPH1 43 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 3 HW-2 MECH AND ELEC 010 0.6 1 120 LVPH1 45 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 HW-1 MECH AND ELEC 010 0.6 1 120 LVPH1 46 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 5 HWRP-1 MECH AND ELEC 010 1 1 208 LVPH1 48,50 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 1 6 DOAS-1 ROOF 19.8 3 208 LVPH4 14,16,18 70A/3P 3-#4, 1-#8EG IN 1¼"C 3-#4, 1-#8EG IN 1¼"C 10, 14 AU 3R 3 7 ODU-1 ROOF 23.0 3 208 LVPH4 11,13,15 80A/3P 3-#4, 1-#8EG IN 1¼"C 3-#4, 1-#8EG IN 1¼"C 10 AU 3R 10 FCU-1 ELMSHADE OFFICES 006 0.5 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 11 FCU-2 SUPPORTING HOUSING OFF 002E 0.5 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 12 FCU-3 SHARED COPY/FILES 004 0.5 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 13 FCU-4 CORRIDOR 100C 0.5 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 14 FCU-5 LAUNDRY 017 0.5 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 15 FCU-6 LAUNDRY 017 0.5 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 16 FCU-7 STAFF BREAK RM 014 0.5 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 17 FCU-8 CORRIDOR 100C 0.5 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 18 FCU-9 CORRIDOR 200 0.5 1 208 LVPH4 7,9 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 19 FCU-11 CORRIDOR 300 0.5 1 208 LVPH4 7,9 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 20 FCU-12 CORRIDOR 400 0.5 1 208 LVPH4 10,12 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 21 FCU-10 CORRIDOR 500 0.5 1 208 LVPH4 10,12 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 30 BCC-1 MECH AND ELEC 010 0.1 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 31 BCC-2 MECH AND ELEC 010 0.1 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 32 BCC-3 CORRIDOR 300 0.1 1 208 LVPH4 7,9 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 33 BCC-4 CORRIDOR 500 0.1 1 208 LVPH4 10,12 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 5 40 EF-2 WOMENS TLT 015 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 2 41 EF-2 MENS TLT 016 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 2 42 EF-3 TRASH/RECYCLE 011 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 43 EF-3 TRASH/RECYCLE 215 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 44 EF-3 TRASH/RECYCLE 315 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 45 EF-3 TRASH/RECYCLE 415 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 46 EF-3 TRASH/RECYCLE 515 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 47 EF-2 STAFF TLT 005 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 2 48 EF-3 CUST 217 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 49 EF-3 CUST 317 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 50 EBB-4 CONFERENCE RM 018 1.0 1 208 LVPH1 35,37 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 51 EBB-4 CONFERENCE RM 018 1.0 1 208 LVPH1 35,37 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 52 EBB-4 CONFERENCE RM 018 1.0 1 208 LVPH1 35,37 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 53 EBB-4T COMMUNITY RM 012 1.0 1 208 LVPEM 23,25 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 54 EBB-4T COMMUNITY RM 012 1.0 1 208 LVPEM 23,25 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 55 EBB-4T COMMUNITY RM 012 1.0 1 208 LVPEM 23,25 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 60 UH-1 MECH AND ELEC 010 5.0 3 208 LVPH1 52,54,56 20A/3P 3-#12, 1-#12EG IN ½"C 3-#12, 1-#12EG IN ½"C 10 AU 1 61 ECUH-1 STAIR B B01 2.0 1 208 LVPH1 47,49 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 62 ECUH-1 VESTIBULE 001 2.0 1 208 LVPH1 51,53 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 63 ECUH-1 VESTIBULE 100D 2.0 1 208 LVPH1 67,69 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 70 EF-3 CUST 417 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 71 EF-3 CUST 517 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 80 HPU-1 ROOF 2.1 1 208 LVPH4 17,19 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 30 NF 10 AU 3R 7 81 IFCU-1 ELEVATOR SHAFT - 1 208 LVPH4 17,19 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 3, 11 AU 1 7 60 NF POST BID ADDENDUM #3 2019.12.31 REVISIONS No. Description Date A3 POST BID ADDENDUM #3 12.19.2019 A8 ELEVATOR SHAFT CONDITIONING 06.15.2020 A9 ECUH REV 08.10.2020 A8 A8 A9 plan ARCHITECTURAL 250 South Avenue, Suite 100 Rochester, New York 14604 Architectural Studio, PC plan t. 585.454.4230 f. 585.454.4237 www.planpc.com STUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. © PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTS TURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e802 ELECTRICAL PANEL SCHEDULESLAKEVIEW HEALTH SERVICES WEST END HEIGHTS 701 WEST COURT STREET, ITHACA, NEW YORK, 14850 17167 11.30.2020 Receptacle 19360 VA 50.00% 9680 VA Other 0 VA 0.00% 0 VA Motor 5276 VA 75.00% 3957 VA TOTAL EST. DEMAND: 146 A Lighting 2946 VA 90.00% 2651 VA TOTAL CONN.: 217 A Heating 18289 VA 65.00% 11888 VA TOTAL EST. DEMAND: 52772 VA Electric Range - 3.5 kW ... 8300 VA 80.00% 6640 VA TOTAL CONN. LOAD: 78103 VA Electric Clothes Dryer 24000 VA 75.00% 18000 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 235 A 223 A 199 A TOTAL LOAD: 27864 VA 26338 VA 23913 VA 71 SPARE 20 A 1 0.0 0.0 -- -- SPACE 72 69 1.0 0.0 -- -- SPACE 70 67 ECUH-1 20 A 2 1.0 0.0 -- -- SPACE 68 65 STAFF TLT HAND DRYER 20 A 1 1.0 1.0 1 20 A DISHWASHER REC 66 63 4.2 0.0 64 61 COMM KIT RANGE 50 A 2 4.2 0.6 2 30 A LCS 62 59 COMM KIT MICROWAVE 20 A 1 1.0 0.2 1 20 A STAFF KIT REC 60 57 W TLT HAND DRYER 20 A 1 1.0 58 55 M TLT HAND DRYER 20 A 1 1.0 1.7 56 53 1.0 1.7 54 51 ECUH-1 20 A 2 1.0 1.7 3 20 A EUH 52 49 1.0 0.4 50 47 ECUH-1 20 A 2 1.0 0.4 2 20 A HWRP-1 48 45 HW-2 20 A 1 0.6 0.6 1 20 A HW-3 46 43 HW-1 20 A 1 0.6 0.0 1 20 A AQUASTAT, TIME SWITCH 44 41 0.9 1.2 42 39 BCC-1, FCU-4, 6, 7, 8 20 A 2 0.9 1.2 2 20 A BCC-2, FCU-1, 2, 3, 5 40 37 1.5 2.0 38 35 CONF RM BASEBOARD 20 A 2 1.5 2.0 2 30 A DRYER 36 33 EF-2(M),EF-2(W),1-2 EF-3 20 A 1 0.1 2.0 34 31 2.0 2.0 2 30 A DRYER 32 29 DRYER 30 A 2 2.0 2.0 30 27 2.0 2.0 2 30 A DRYER 28 25 DRYER 30 A 2 2.0 1.0 1 20 A WASHER REC 26 23 2.0 1.0 1 20 A WASHER REC 24 21 DRYER 30 A 2 2.0 1.0 1 20 A WASHER REC 22 19 WASHER REC 20 A 1 1.0 1.4 1 20 A 2ND FLR CORRIDOR REC 20 17 WASHER REC 20 A 1 1.0 1.0 1 20 A STAFF MICROWAVE 18 15 WASHER REC 20 A 1 1.0 0.9 1 20 A STAFF, COMM KIT REC 16 13 COMM KITCHEN REC 20 A 1 0.7 1.1 1 20 A CONFERENCE, LAUN REC 14 11 CORR, EXT, TRASH REC 20 A 1 1.4 12 9 RECEPTION OFF REC 20 A 1 1.3 10 7 ELMSHADE COPY REC 20 A 1 1.0 0.2 8 5 ELMSHADE MED, OFF REC 20 A 1 0.7 0.2 2 20 A SITE LIGHTING 6 3 BLD MAIN OFF REC 20 A 1 0.7 1.3 1 20 A 1ST, 2ND FLR CORR LTG 4 1 EXT, MECH, OFF REC 20 A 1 0.7 1.0 1 20 A OFF,CONF,BREAK LTG 2 CKT CIRCUIT DESCRIPTION TRIP POLES A B C POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: PANEL IS 2 SECTION LVPH1 MECHANICAL AND... 225 A 3Ø, 4W 120/208 WYE SURFACE 22 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS X SPD SIZE: 60PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS X INTEGRAL SPD X TOTAL EST. DEMAND: 35 A TOTAL CONN.: 62 A Receptacle 14728 VA 50.00% 7364 VA TOTAL EST. DEMAND: 12698 VA Motor 4960 VA 75.00% 3720 VA TOTAL CONN. LOAD: 22161 VA Heating 3000 VA 65.00% 1950 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 64 A 53 A 71 A TOTAL LOAD: 7549 VA 6327 VA 8316 VA 41 SPACE -- -- 0.0 1.0 42 39 SPACE -- -- 0.0 1.0 40 37 SPACE -- -- 0.0 1.0 3 60 A ELEVATOR 38 35 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 36 33 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 34 31 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 32 29 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 30 27 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 28 25 1.5 0.0 1 20 A SPARE 26 23 COMM RM BASEBOARD 20 A 2 1.5 1.0 1 20 A STAFF REF RECEPT 24 21 IT RM 516 REC 20 A 1 0.4 0.7 1 20 A IT RM 516 REC 22 19 IT RM 416 REC 20 A 1 0.4 0.7 1 20 A IT RM 416 REC 20 17 IT RM 316 REC 20 A 1 0.4 0.7 1 20 A IT RM 316 REC 18 15 IT RM 216 REC 20 A 1 0.4 0.7 1 20 A IT RM 216 REC 16 13 SERVER RM RECEPT 20 A 1 0.4 0.4 1 20 A SERVER RM RECEPT 14 11 5TH PANIC BUTTON REP 20 A 1 1.0 1.0 1 20 A VEST 100D DOOR OP 12 9 4TH PANIC BUTTON REP 20 A 1 1.0 1.0 1 20 A VEST 001 DOOR OP 10 7 3RD PANIC BUTTON REP 20 A 1 1.0 1.1 1 20 A COMMUNITY RM REC 8 5 2ND PANIC BUTTON REP 20 A 1 1.0 1.0 1 20 A COMM KIT REF REC 6 3 1ST PANIC BUTTON REP 20 A 1 1.0 0.2 1 20 A ELMSHADE UC REF REC 4 1 ELEV SUM PUMP 20 A 1 1.2 0.2 1 20 A HORIZON UC REF REC 2 CKT CIRCUIT DESCRIPTION TRIP POLES A (kVA) B (kVA) C (kVA) POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPEM MECHANICAL AND... ATS-E 225 A 3Ø, 4W 120/208 WYE SURFACE 22 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS SPD SIZE:PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND: 13 A Receptacle 540 VA 100.00% 540 VA TOTAL CONN.: 16 A Motor 1400 VA 75.00% 1050 VA TOTAL EST. DEMAND: 4794 VA Lighting 3199 VA 90.00% 2879 VA TOTAL CONN. LOAD: 5638 VA Heating 500 VA 65.00% 325 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 25 A 26 A 18 A TOTAL LOAD: 2947 VA 2975 VA 2217 VA 29 SPACE -- -- 0.0 0.2 1 20 A GEN RECEPTACLE 30 27 SPACE -- -- 0.0 0.5 1 20 A GEN BATTERY CHARGER 28 25 SPACE -- -- 0.0 0.5 1 20 A GEN BLOCK HEATER 26 23 SPACE -- -- 0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 20 17 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 18 15 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 16 13 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 14 11 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 12 9 SMOKE DAMPERS 20 A 1 0.9 1.0 1 20 A LCP 10 7 COMMUNITY RM LTG 20 A 1 0.6 0.3 1 20 A EXTERIOR EM LTG 8 5 ELEVATOR CAB LTG 20 A 1 0.5 1.5 1 20 A 1ST FLR LIFE SAFETY LTG 6 3 ELEV SHAFT LTG, REC 20 A 1 0.4 0.2 1 20 A 2-5 FLR LIFE SAFETY LTG 4 1 FACP 20 A 1 1.5 0.0 1 20 A EXIT SIGNS 2 CKT CIRCUIT DESCRIPTION TRIP POLES A B C POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPLS MECHANICAL AND... ATS-LS 100 A 3Ø, 4W 120/208 WYE SURFACE 22 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS SPD SIZE:PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND: 19 A TOTAL CONN.: 20 A Receptacle 5860 VA 100.00% 5860 VA TOTAL EST. DEMAND: 6823 VA Lighting 351 VA 90.00% 316 VA TOTAL CONN. LOAD: 7207 VA Heating 1000 VA 65.00% 650 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 27 A 17 A 17 A TOTAL LOAD: 3248 VA 1980 VA 1980 VA 29 SPACE -- -- 0.0 0.0 -- -- SPACE 30 27 SPACE -- -- 0.0 0.0 -- -- SPACE 28 25 SPACE -- -- 0.0 0.0 -- -- SPACE 26 23 SPACE -- -- 0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPARE 20 A 1 0.0 0.0 -- -- SPACE 20 17 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 18 15 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 16 13 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 14 11 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 12 9 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 10 7 HORIZON DIR, MGR REC 20 A 1 0.9 1.0 1 20 A HORIZON HD 8 5 HORIZON OFF, WAIT REC 20 A 1 1.1 0.9 1 20 A HORIZON PROG, MED REC 6 3 SUPPORT HOUSE REC 20 A 1 0.7 1.3 1 20 A HORIZON OFF REC 4 1 HORIZON OFF LTG 20 A 1 0.4 1.0 1 20 A HORIZON COPY REC 2 CKT CIRCUIT DESCRIPTION TRIP POLES A (kVA) B (kVA) C (kVA) POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPHZ SHARED COPY /... 225 A 3Ø, 4W 120/208 WYE FLUSH 22 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS SPD SIZE:PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND: 73 A Receptacle 5780 VA 100.00% 5780 VA TOTAL CONN.: 86 A Motor 3494 VA 75.00% 2621 VA TOTAL EST. DEMAND: 15267 VA Lighting 252 VA 90.00% 227 VA TOTAL CONN. LOAD: 17826 VA Electric Range - 3.5 kW ... 8300 VA 80.00% 6640 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 83 A 88 A TOTAL LOAD: 8581 VA 9245 VA 23 SPACE -- -- 0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPACE -- -- 0.0 0.0 -- -- SPACE 20 17 SPACE -- -- 0.0 0.0 -- -- SPACE 18 15 SPACE -- -- 0.0 0.0 -- -- SPACE 16 13 1.4 0.0 -- -- SPACE 14 11 VRP-12K 20 A 2 1.4 1.0 1 20 A DISHWASHER 12 9 REF RECEPT 20 A 1 X 1.0 4.2 10 7 KIT REC, HOOD FAN/LTG 20 A 1 X 0.7 4.2 2 50 A RANGE RECEPT 8 5 BEDROOM RECEPT 20 A 1 X 0.9 0.5 X 1 20 A KITCHEN RECEPT 6 3 ENTRY, DINING RECEPT 20 A 1 X 0.9 1.1 X 1 20 A LIVING RM RECEPT 4 1 APARTMENT LTG 20 A 1 X 0.4 0.2 X 1 20 A BATHROOM RECEPT 2 CKT CIRCUIT DESCRIPTION TRIP POLES AFCI A (kVA) B (kVA) AFCI POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LC214 (TYPE 3)... 100 A 1Ø, 3W 120/208... FLUSH 10 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE:LOADCENTER SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND: 73 A Receptacle 5780 VA 100.00% 5780 VA TOTAL CONN.: 86 A Motor 3494 VA 75.00% 2621 VA TOTAL EST. DEMAND: 15242 VA Lighting 224 VA 90.00% 202 VA TOTAL CONN. LOAD: 17798 VA Electric Range - 3.5 kW ... 8300 VA 80.00% 6640 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 85 A 86 A TOTAL LOAD: 8793 VA 9005 VA 23 SPACE -- -- 0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPACE -- -- 0.0 0.0 -- -- SPACE 20 17 SPACE -- -- 0.0 0.0 -- -- SPACE 18 15 SPACE -- -- 0.0 0.0 -- -- SPACE 16 13 DISHWASHER 20 A 1 1.0 0.0 -- -- SPACE 14 11 1.4 0.0 -- -- SPACE 12 9 VRP-12K 20 A 2 1.4 4.2 10 7 KITCHEN RECEPT 20 A 1 X 0.5 4.2 2 50 A RANGE RECEPT 8 5 KIT REC, HOOD FAN/LTG 20 A 1 X 0.7 1.0 X 1 20 A REF RECEPT 6 3 ENTRY, BEDRM RECEPT 20 A 1 X 1.4 1.4 X 1 20 A MECH, LIV, BEDRM REC 4 1 APARTMENT LTG 20 A 1 X 0.3 0.2 X 1 20 A BATHROOM RECEPT 2 CKT CIRCUIT DESCRIPTION TRIP POLES AFCI A (kVA) B (kVA) AFCI POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LC213 (TYPE 4)... 100 A 1Ø, 3W 120/208... FLUSH 10 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE:LOADCENTER SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND: 71 A Receptacle 5240 VA 100.00% 5240 VA TOTAL CONN.: 83 A Motor 3494 VA 75.00% 2621 VA TOTAL EST. DEMAND: 14702 VA Lighting 224 VA 90.00% 202 VA TOTAL CONN. LOAD: 17258 VA Electric Range - 3.5 kW ... 8300 VA 80.00% 6640 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 71 A 92 A TOTAL LOAD: 7333 VA 9925 VA 23 SPACE -- -- 0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPACE -- -- 0.0 0.0 -- -- SPACE 20 17 SPACE -- -- 0.0 0.0 -- -- SPACE 18 15 SPACE -- -- 0.0 0.0 -- -- SPACE 16 13 SPACE -- -- 0.0 0.0 -- -- SPACE 14 11 1.4 1.0 1 20 A DISHWASHER REC 12 9 VRP-12K 20 A 2 1.4 4.2 10 7 REF RECEPT 20 A 1 X 1.0 4.2 2 50 A RANGE RECEPT 8 5 KITCHEN RECEPT 20 A 1 X 0.5 0.7 X 1 20 A KIT REC, HOOD FAN/LTG 6 3 ENTRY, LIVING RECEPT 20 A 1 X 1.3 1.1 X 1 20 A BEDROOM RECEPT 4 1 APARTMENT LTG 20 A 1 X 0.3 0.2 X 1 20 A BATHROOM RECEPT 2 CKT CIRCUIT DESCRIPTION TRIP POLES AFCI A (kVA) B (kVA) AFCI POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LC202 (TYPE 2)... 100 A 1Ø, 3W 120/208... FLUSH 10 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE:LOADCENTER SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND: 118 A TOTAL CONN.: 151 A Receptacle 5760 VA 100.00% 5760 VA TOTAL EST. DEMAND: 42468 VA Motor 47511 VA 75.00% 35633 VA TOTAL CONN. LOAD: 54465 VA Lighting 1194 VA 90.00% 1075 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 151 A 151 A 152 A TOTAL LOAD: 18073 VA 18103 VA 18289 VA 29 SPACE -- -- 0.0 0.0 -- -- SPACE 30 27 SPACE -- -- 0.0 0.0 -- -- SPACE 28 25 SPACE -- -- 0.0 0.0 -- -- SPACE 26 23 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 24 21 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 22 19 1.1 0.0 1 20 A SPARE 20 17 HPU-1, IFCU-1 20 A 2 1.1 6.6 18 15 7.7 6.6 16 13 7.7 6.6 3 70 A DOAS-1 14 11 ODU-1 80 A 3 7.7 0.6 12 9 0.6 0.6 2 20 A BCC-4, FCU-10, FCU-12 10 7 BCC-3, FCU-9, FCU-11 20 A 2 0.6 0.5 1 20 A RADON FANS 8 5 5TH FLR CORR RECEPT 20 A 1 1.6 0.7 1 20 A RADON FANS 6 3 4TH FLR CORR RECEPT 20 A 1 1.4 1.2 1 20 A 3RD, 4TH, 5TH CORR LTG 4 1 3RD FLR CORR RECEPT 20 A 1 1.4 0.1 1 20 A 3RD-5TH FLR EF-3'S 2 CKT CIRCUIT DESCRIPTION TRIP POLES A B C POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPH4 I.T. CLOSET 216 225 A 3Ø, 4W 120/208 WYE SURFACE 10 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS SPD SIZE:PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD METER CENTERMECH AND ELEC 010 METER CENTER METER CENTERMETER CENTER METER CENTER SHUNT TRIP MECH AND ELEC 010 MECH AND ELEC 010 SHARED COPY/FILES 4TH FLR IT ROOM METER CENTER REVISIONS No. Description Date A1 A-1 Addendum 10.23.2019 A7 SITEWORK & STORAGE SHED 05.15.2020 A8 ELEVATOR SHAFT CONDITIONING 06.15.2020 A9 ECUH REV 08.10.2020 A15 ASI-15 APT DW 12.07.20 A17 ELMSHADE METER 04.19.2021 METER CENTER A17 TOTAL EST. DEMAND: 21 A TOTAL CONN.: 22 A Receptacle 3420 VA 100.00% 3420 VA TOTAL EST. DEMAND: 4292 VA Lighting 249 VA 90.00% 224 VA TOTAL CONN. LOAD: 4666 VA Heating 1000 VA 65.00% 650 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS: 26 A 17 A TOTAL LOAD: 2866 VA 1800 VA 11 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 12 9 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 10 7 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 8 5 ELMSHADE MED, OFF REC 20 A 1 0.9 1.0 1 20 A ELMSHADE MED HD 6 3 ELMSHADE OFF REC 20 A 1 0.9 0.9 1 20 A ELMSHADE OFF REC 4 1 ELMSHADE LTG 20 A 1 0.2 0.7 1 20 A PROG, BLDG MAIN REC 2 CKT CIRCUIT DESCRIPTION TRIP POLES A (kVA) B (kVA) POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPELM ELMSHADE MED.... 100 A 1Ø, 3W 120/208... FLUSH 10 QO TYPE 1 MCB MLO NAME LOCATION SOURCE RATING (AMPS) PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE:PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD CofO As-Builts/Fire Alarm As-Builts.pdf CofO As-Builts/Fire Protection As-Builts.pdfMicrosoft Word - O&MCoverPage.docx CofO As-Builts/HVAC As-Builts.pdfEC Start Drawing Template (US Imperial) WWWWWW DDDDDD 2 3 4 5 6 7 8 10 11 12 14 13 16 A C D E F G H I A.5 B 7.6 B.1 15.5 15.6 H.3 9 DRAWING NO DRAWING TITLE JOB TITLE 14902 1322 COLLEGE AVENUE ELMIRA, NY SOUTHERNTIER CUSTOM FABRICATORS THESE PLANS ARE THE EXCLUSIVE PROPERTY OF SOUTHERNTIER CUSTOM FAB., AND ANY USE THEREOF WITHOUT THE WRITTEN CONSENT OF SOUTHERNTIER IS EXPRESSLY PROHIBITED. DATE REVISIONS BYDATEDESCRIPTIONNO CO-ORDINATION SIGN OFF DATEBYCOMPANY DATE SCALE DRAWN BY OF JOB No(607) 732-0927 CURRENT AS STCF YOUR RESPONSIBLE PARTNER KEY PLAN H101 10/21/2020 1/4" = 1'-0" MM 20779-A GROUND FLOOR PLAN - HVAC LAKEVIEW HEALTH SERVICES ITHACA, NY REFERENCE # H101 1 SHIFTED SA TRUNKLINE 6" TO THE EAST. AS BUILT. 9/9/2021 MM 9/9/2021 9/10/2021 AS BUILT DRAWING 2 3 4 5 6 7 8 10 11 12 14 13 167.6 15.5 15.69 1 2 3 DRAWING NO DRAWINGTITLE JOBTITLE 14902 1322 COLLEGE AVENUE ELMIRA, NY XXX XXX SOUTHERNTIER CUSTOM FABRICATORS THESE PLANS ARE THE EXCLUSIVE PROPERTY OF SOUTHERNTIER CUSTOM FAB., AND ANY USE THEREOF WITHOUT THE WRITTEN CONSENT OF SOUTHERNTIER IS EXPRESSLY PROHIBITED. DATE REVISIONS BY DATE DESCRIPTION NO CO-ORDINATION SIGN OFF DATE BY COMPANY DATE SCALE DRAWN BY CHECKED BY JOB No (607) 732-0927 DESIGNED BY STCF YOUR RESPONSIBLE PARTNER KEY PLAN H102 12/1/20 1/4"=1'-0" MM 20779-A TYPICAL FLOORS 2-5 LAKEVIEW HEALTH SERVICES ITHACA, NY REF DWG: H102 1SHIFTED EA & WALL CAP 9'-7" TO THE EAST. AS BUILT.9/10/2021MM9/10/2021 2MOVED WALL CAP FROM THE NORTH WALL TO THE EAST WALL. AS BUILT.9/10/2021MM9/ 10/2021 3SHIFTED FCU 3'-0" TO THE EAST. AS BUILT.9/10/2021MM9/10/2021 AS BUILT DRAWING CofO As-Builts/Plumbing As-Builts.pdfunknown title CofO Reports/2019-11-01 Basic SWPPP.pdf Lakeview Health Services West End Heights 709 West Court Street Basic Stormwater Pollution Prevention Plan City of Ithaca Tompkins County, New York Prepared for: Lakeview Health Services 600 Washington Street Geneva, NY 14456 Prepared by: T.G. Miller P.C. 203 North Aurora Street Ithaca, New York 14850 (607) 272-6477 November 1, 2019 TABLE OF CONTENTS PROJECT DESCRIPTION 1 STORMWATER DRAINAGE 1 CONTROLS 2 MAINTENANCE AND INSPECTIONS 3 CERTIFICATION AND COMPLIANCE WITH LOCAL REGULATIONS 4 CERTIFICATION FORMS CONTRACTOR/SUBCONTRACTOR CERTIFICATION FORM 1 FIGURES EXISTING GROUND COVER MAP 1 OF 2 PROPOSED GOUND COVER MAP 2 O F 2 CONSTRUCTION DRAWINGS EXISTING CONDITIONS PLAN C101 EROSION AND SEDIMENT CONTROL PLAN C102 UTILITY PLAN C103 DETAILS C201 Lakeview Health Services - West End Heights Basic Stormwater Pollution Prevention Plan T.G. Miller, P.C. 1. November 1, 2019 PROJECT DESCRIPTION The project is located on 4 currently developed parcels of land on West Court Street and North Meadow Street described as Tax Map Parcels 59.-2-9, 10, 12 and 13. The project consists of the demolition of the buildings on all 4 parcels and removal of all existing site improvements. Proposed site improvements include vehicular and pedestrian access, utility extensions and relocations, storm water collection, landscaping and lighting. Redevelopment includes the construction of a multi-story apartment building. The project will disturb a total of 0.94 acres of land, thus requiring the preparation of a Basic Stormwater Pollution Prevention Plan (SWPPP) in compliance with Chapter 282 of the City of Ithaca Code. Conformance with the NYSDEC SPDES General Permit (GP-0-15-002) is not applicable. The stormwater management objectives presented in this SWPPP focus primarily on controlling erosion and sedimentation during construction, installing stormwater collection systems and stabilization of the site. All areas of the site have been previously disturbed and the on-site soils are best described as manmade. There is no evidence of any wetlands located on or adjacent to the site. Stormwater runoff from the site drains to the City of Ithaca storm sewer collection system in West Court Street and the NYSDOT system in North Meadow Street. The outfall from this portion of the system is at the Cayuga Inlet to the northwest. The site is not located in a mapped 100-year floodplain. STORMWATER DRAINAGE Existing Conditions Storm water runoff from the site drains to perimeter roadway drainage systems in West Court and North Meadow Streets. A portion of the properties drain to a lawn area to the south of West Court Street where runoff presumably infiltrates. 28,907 square feet, or approximately 71%, of the site is currently impervious (Sheet 1 of 2). According to the FEMA Firm Map dated 1981, the project site is located in the 500-year flood boundary. Existing (pre-developed) site conditions and drainage facilities are shown on Sheet C101 of the attached drawings. Proposed Conditions The total site disturbance will be under one acre. Under the City stormwater requirements, disturbances of more than ¼ acre and less than 1.0 acres, that do not create more than ½ acre of impervious cover will require a Basic Stormwater Pollution Prevention Plan (SWPPP) be prepared including temporary erosion and sediment control practices. The proposed stormwater management approach was to closely match the existing drainage patterns. As such an infiltration test was done in the existing lawn area to confirm suitable soils for infiltration. The infiltration test resulted in no infiltration rendering the site unsuitable for the installation of dry wells or other infiltration practices. Stormwater will be collected by an on-site stormwater system and be piped north to the existing drainage system in West Court Street. Surface runoff from small portions of the site will drain to the West Court and North Meadow Street storm sewers by means of overland flow. A total of 29,729 square feet, or approximately 73.0%, of the proposed site will be impervious cover after construction Lakeview Health Services - West End Heights Basic Stormwater Pollution Prevention Plan T.G. Miller, P.C. 2. November 1, 2019 is complete. The 822 square foot increase in impervious cover represents a minor increase in runoff to the City system (Sheet 2 of 2). The proposed site and drainage improvements are shown on Sheet C103 of the attached drawings. Better Site Design In accordance with City Code, projects disturbing less than one acre must apply at least two site design practices from a list of techniques described in the April 2008 NYSDEC publication titled “Better Site Design”. Given the project is redeveloping a previously disturbed site, it inherently employs Practice 4 – Locating Sites in Less Sensitive Areas. Since the proposed building is multistory, the project also employs Practice #10 – Building Footprint Reduction. CONTROLS Erosion and Sediment Controls The proposed temporary erosion and sediment control practices, and a detailed sequencing of the major construction activities, are as indicated and described on the attached Erosion and Sediment Control Plan (Sheet C102) drawing. Other Controls Waste Disposal All waste materials will be collected and stored in securely lidded metal dumpsters rented from a local waste management company which must be a solid waste management company licensed to do business in Tompkins County. The dumpsters will comply with all local and state solid waste management regulations. All trash and construction debris from the site will be deposited in the dumpsters. The dumpsters will be emptied a minimum of twice per week or more often if necessary, and the trash will be hauled to a landfill approved by New York State. No construction waste materials will be buried on site. All personnel will be instructed regarding the correct procedures for waste disposal. Notices stating these practices will be posted in the job site construction office trailer, and the job site superintendent will be responsible for seeing that these procedures are followed. Sanitary Waste All sanitary waste will be collected from portable units a minimum of two times per week by a licensed portable facility provider in complete compliance with local and state regulations. Off-Site Vehicle Tracking A stabilized construction exit (Tracking Pad) will be provided to help reduce vehicle tracking of sediments. The paved streets adjacent to the site entrance will be inspected daily and cleaned with vacuum equipment as necessary to remove any excess mud, dirt, or rock tracked from the site. Dump trucks hauling material from the construction site will be covered with a tarpaulin. The job site superintendent will be responsible for seeing that these procedures are followed. Hazardous Substances and Hazardous Waste All hazardous waste materials will be disposed of by the Contractor in the manner specified by local, state, and/or federal regulations and by the manufacturer of such products. Site personnel will be instructed in these practices by the job site superintendent, who will also be responsible for seeing that these practices are followed. Material Safety Data Sheets (MSDS's), for each substance with hazardous properties that is used on the job site, will be obtained and used for the proper management Lakeview Health Services - West End Heights Basic Stormwater Pollution Prevention Plan T.G. Miller, P.C. 3. November 1, 2019 of potential wastes that may result from these products. An MSDS will be posted in the immediate area where such product is stored and/or used and another copy of each MSDS will be maintained in the SWPPP file at the job site construction trailer. Each employee who must handle a substance with hazardous properties will be instructed on the use of MSDS sheets and the specific information in the applicable MSDS for the product he/she is using, particularly regarding spill control techniques. Any spills of hazardous materials which are in quantities in excess of Reportable Quantities as defined by EPA regulations shall be immediately reported to the EPA National Response Center 1800-424-8802. In order to minimize the potential for a spill of hazardous materials to come into contact with stormwater, the following steps will be implemented: • All materials with hazardous properties (such as pesticides, petroleum products, fertilizers, detergents, construction chemicals, acids, paints, paint solvents, cleaning solvents, additives for soil stabilization, concrete curing compounds and additives, etc.) will be stored in a secure location, under cover, when not in use. • The minimum practical quantity of all such materials will be kept on the job site. • A spill control and containment kit (containing, for example, absorbent such as kitty litter or sawdust, acid neutralizing powder, brooms, dust pans, mops, rags, gloves, goggles, plastic and metal trash containers, etc.) will be provided at the storage site. • All of the products in a container will be used before the container is disposed of. All such containers will be triple-rinsed with water prior to disposal. The rinse water used in these containers will be disposed of in a manner in compliance with state and federal regulations and will not be allowed to mix with stormwater discharges. • All products will be stored in and used from the original container with the original product label. • All products will be used in strict compliance with instructions on the product label. • The disposal of excess or used products will be in strict compliance with instructions on the product label. The building is known to contain asbestos and will be demolished under local, state and federal regulations. MAINTENANCE AND INSPECTIONS The applicant or developer of the land development activity or his/her representative shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the applicant or developer to achieve compliance with the conditions of these regulations. The Stormwater Management Officer (SMO) may require such inspections as necessary to determine compliance with the SWPPP and may either approve that portion of the work completed or notify the applicant wherein the work fails to comply with the requirements of the regulations and the SWPPP as approved. The applicant shall notify the SMO when any of the following occurs: • Commencement of construction. • Commencement of installation of sediment and erosion control measures. • Commencement of site clearing. • Commencement of rough grading. • Close of the construction season. • Completion of final landscaping. • Successful establishment of landscaping in public areas. Lakeview Health Services - West End Heights Basic Stormwater Pollution Prevention Plan T.G. Miller, P.C. 4. November 1, 2019 Additionally, the City of Ithaca may conduct random inspections during any phase of construction. If any violations are found, the applicant and developer shall be notified in writing of the nature of the violation and the required corrective actions. No further work shall be conducted, except for site stabilization, until any violations are corrected and all work previously completed has received approval by the SMO. CERTIFICATION AND COMPLIANCE WITH LOCAL REGULATIONS Contractor Certification The Contractor will review and comply with all conditions of Chapter 282 of the City Code. Each contractor and subcontractor who will be involved in soil disturbance and/or stormwater management practice installation shall sign and date a copy of the attached certification (Form 1) before undertaking any land development activity. A copy of all SWPPP documents shall be retained at the site of the land development activity during construction from the date of initiation of construction activities to the date of final stabilization. Engineer’s Certification on Compliance with Local Regulations This Basic Stormwater Pollution Prevention Plan reflects the City of Ithaca’s requirements for stormwater management and erosion and sediment control. Name: Andrew J. Sciarabba, P.E. Title: Vice President Acting as Professional Engineer for: T.G. Miller, P.C. Signature: Date: 11/1/2019 FORM 1 CONTRACTOR/SUBCONTRACTOR CERTIFICATION Construction Site: Lakeview Health Services – West End Heights Project City of Ithaca, Tompkins County, New York CONTRACTOR/SUBCONTRACTOR'S CERTIFICATION: "I certify under penalty of law that I understand and agree to comply with the terms and conditions of the Basic Stormwater Pollution Prevention Plan (SWPPP). I also understand that it is unlawful for any person to cause or contribute to a violation of water quality standards." CONTRACTOR Name: Signature: (Print) Title: Date: Company Name: Phone Number: Address: SUBCONTRACTOR Name: Signature: (Print) Title: Date: Company Name: Phone Number: Address: SUBCONTRACTOR Name: Signature: (Print) Title: Date: Company Name: Phone Number: Address: Note: Provide addition forms as necessary for addition contractors or subcontractors. ‹ NOT FOR CONSTRUCTION 387.0 387.0 387.0 386.5 386.0 386.5 386.5 387.0 387.5 387.0 386.5 386.5 386.5 386.0 ‹ NOT FOR CONSTRUCTION 387.0 387.0 387.0 386.5 386.0 386.5 386.5 387.0 387.5 387.0 386.5 386.5 386.5 386.0 ‹ NOT FOR CONSTRUCTION x x x ‹ NOT FOR CONSTRUCTION CofO Reports/2020-08-12 Water Main Hydrostatic & Leakage Test.pdf CofO Reports/2021-04-13 Water Main Disinfection.pdf CofO Reports/2021-04-13 Water Main Flush Record.pdf CofO Reports/2021-04-26 DOH Approval of Backflow Prevention Device.pdf Ph: (607) 274-6688 Fx: (607) 274-6695 Inclusion Through Diversity https://tompkinscounty-my.sharepoint.com/personal/sfreyburger_tompkins-co_org/Documents/Approval of Plans.docx Created 2/8/19 ENVIRONMENTAL HEALTH DIVISION www.tompkinscountyny.gov/health/eh Approval of Plans Public Water Supply – Backflow Prevention Device(s) Tompkins County Environmental Health Record #: EH-PR-20-006 These plans are APPROVED in accordance with the New York State Sanitary Code 5-1 and consists of 18 sheets: Design Professional: Daniel D. Turner, P.E. Project/Job #: 001.16.01.02 Lakeview Health Services West end Heights Plan Design Date: 11.30.2020 Plan Revision Date: NA Project Location: 701 West Court Street Municipality: City of Ithaca Tax Parcel Id: 500700-59.-2-10 Project Description: 4" Domestic and 6" Fire Protection Backflow Prevention This approval of plans is issued subject to the following conditions: 1) THAT this approval is valid until 4/26/2023 and new plans must be submitted for approval if the project is not completed by then. 2) THAT within 45 days of installation, the attached certification will be completed and returned to the water supplier, City of Ithaca and the Tompkins County Health Department. 3) THAT a certified backflow prevention device tester checks the above backflow prevention device(s) at least yearly and reports the results to the water supplier indicated above. 4) THAT any connection made prior to the backflow prevention device(s) shall render this approval void. The approved plans and Report of Test & Maintenance of Backflow Prevention Device Form DOH-1013 is attached. Form DOH-1013 is used as a Request for Completed Works, which consists of two parts: 1) The initial test of the device(s) by a certified backflow prevention device tester. 2) A Certification that installation is in accordance with approved plans by the design professional or the water supplier. , P.E. Approval Date Scott Freyburger, Public Health Engineer ec: Design Professional, Owner, CEO, PWS Contact, TCHD: Elizabeth Cameron, Program Staff scan: Signed copy to Accela and F:Drive 4/26/2021 CofO Reports/2021-08-02 Sprinkler Inspections.pdf ( ~ OSKY PROTl!CTION Field Test Sheets Job Name: \.Jc-::i~ led Job#.......,: j@ _ -..... f ( ..... .. O ____ _ Building Section: ty\\ ~) ·,\c\, , _, c ,5~-rA~·~, (r'Xf -tcf-!h {lcor I Dn,) s\rs±Lro) Authority Having Jurisdiction: -----------Test: Fire Sprinkler Hydrostatic Test: PSI: Joo Duration: .1 H Rs Fire Main Hydrostatic Test: PSI: __ _ Duration: Date: --- --Fire Main Flushing Test: GPM: __ _ Duration: --- Date: --Other: PSI: Duration: - - - GPM: --- --- Date: --Notes: ----------------------------Petcosky Fire Field Representative: ::J:'L ~ Authority Having Jurisdiction: ~ ~~ ~ v Date: 2/Jcy J..1 Date:~Z I Petcoskyfire.com !P.O. Box 19Vestal, NY 138501Ph.607-797-0160 Fax. 607-770-4482 CofO Reports/2021-08-09 Above Ground Piping Test.pdf CofO Reports/2021-08-09 Standpipe Rooftop Flow Test.pdf r-::+< ~ P-TCosKv ~, 'llllil' ~~~::!~~r!'!...~ Field Test Sheets Job Name: lt.ll-# [not Job#: Jrfi-/(cf) Building Section: Po:z\ 'lop fbL.> ±t:t-± LIL A 8 1 ~ Authority Having Jurisdiction: ___ r ____ v~ -----~~----Fire Sprinkler Hydrostatic Test: PSI: __ _ Duration: --- Date: --Fire Main Hydrostatic Test: PSI: __ _ Duration: Date: --Fire Main Flushing Test: GPM: __ _ Duration: --- Date: Other: PSI: __ _ Petcosky Fire Field Representative: ~ ~ Authority Having Jurisdiction: ~ /'5~ ~ ~ ----Date: fl /)vf ,t.j Date:#OC-) Petcoskyfire.com I P.O. Box 19 Vestal, NY 13850 I Ph. 607-797-0160 Fax. 607-770-4482 CofO Reports/2021-08-11 Standpipe Test.pdf CofO Reports/2021-08-13 DOH RPZ Backflow Prevention Device Testing.pdf NEW YORK STATE DEPARTMENT OF HEALTH Bureau of Public Water Supply Protection Report on Test and Maintenance of Bacldlow Prevention Device For Iha year (-0) \ i@fj Please use 11 separate form for each device. cm lnttial test • Complete entire form D Annual test • Complete Part A only Account No. County lock Lot Cc, (.JC. ( Faclllty Name Le, ki._,\l \ i.\J \\e c.\-\k <:~~ ,..\J\ ct_i Location~! Dav fr ................. ::H:s?.0. ... : ....... 0..tl.L .................................................. . Address '?f:l·····}:J .. <;.§i± .... .Cc:<.Y..\':'J. .. ~ ...... \:\.h.r"~··"'··..l'f/··/..Y.f°.!;.c.' 41-e(~ /Zc•,,.._ .... !..~ ..................................................................................................... .. Line Pressure S' 7 psi Closed tight Opened at ~' C,, psid Date lolril []] Im Pressure dro~?Cross first check valve _ZJ_ psid m d y Repaired by Name _______ _ lie 11 _______ _ Date repaired OJ DJ OJ m d y Closed tight c:J Pressure drop across first check valve psid Closed tight c:J Opened at ___ psid Date rnrnrn Water Meter Number 7o clo& <flf Meter Reading .... ~·o TY!fS of Service: (check one) r£1 Domestic 0 Fire 00thef m d y Remarks (Describe deffdencies: bypa!i.Ses, outlets before the device, connections between the device and point or entry, missing or Inadequate mroap, etc.) Certttication: This device meets. D does NOT meet, the requirements of an acceptable containment device at the time of testing I hereby cartify the foregoing data to be correct \c\v, C:r11 wAn Zc 31 Print Name Certified Tester No-. Expiration Date --··-. -----:;,l..------------"---'--'--"----"--==---1 Property owner's (or owner's agent) certification that test was performed: ... ff'.~:":::1 •••••••••••• e.c:.:~t:J.:.!.::::..:-2........................... . ............ :-S.~""'11~.-:~~.-,\,,, .............................. . Print Name Title .~./2- . SiQn~ture ............................................... . i@i:ii Certfflcation that installation is In accordance with the approved plans. (To be completed by Ille design anginear or architect ___ _ or water suppller.) I hereby certlliy that this Installation has been made in accordance with the approved plans. !'-N_am_• ___________ -+=-n-111e ___________ --; Date ITJ m ITJ j License Number Phone ( m '-iJ' y NYSDOH Log# j Representing Describe minor installation changes i"Adci;;;~· .. ··· ... ... .................... ... . .. ... ... . . . ..... . . . . . . .. . . .. . ..... . [ciiY ....................................... ··· ··· ···T5;;;r;; .. ···· ···· · ... . ··y2;;;·· . .. . . .. . ...... . Signature _______________ _ NOTE: Send on& completed copy to the designated health department representatlVe and one copy to the water suppl1ar within 30 days of testing of the OOvh::&. DOH·1013 (9191) Notify owner and water suppller Immediately If device falls test and repairs cannol lmmedlately be ma<:le. WHITE • OFFICE COPY YELLOW · CUSTOMER COPY PINK • NYS DEPARTMENT OF HEALTH NEW YORK STATE DEPARTMENT OF HEAL TH Bureau of Public Waler Supply Protection Report on Test and Maintenance of Bacldlow Prevention Device For the year 'J-0 J- \ •@i1 Please use 11 separate loim for each device. 12£1 Initial test • Compfete entire form D Annual test - Complete Part A only Supply Account No. County Co,'(VCi h Block lot Faclllty Name l.A.7\ \\.-(\) \ e.,\ i \\.f' c,\'\\, ';,,-t r·\I i C ·u loqijlon o~e v r\.•...• .1;;;?.<::~C,. ......... \J.0.l .. : ............................... ··························· Address ·z'?..?. .... ~::-J .. ::."'~: .... C:.,;;is-:.t.\ ... '::~~ ...... \\hr.:.\-i, .... .IY•:f. ..... tt.fS...9. ..... . 11'1-<:.J:J, 0 •:c:, I" ............................... ~ ...................... _.,., .......................................... .. street city ,;p line Pressure '?7 psi Closed tight Opened at /), f psid Date ~ [ill Im] Pressure dror:i across first check valve [~_L psid m d y Repaired by Name _______ _ Uc# _______ _ Date repaired DJ DJ DJ m d y Closed tight c:J Pressure drop across first check valve __ . _ psid Closed tight Opened at ___ psid Date rnrnrn Water Meter Number 1o c;;c,t/Cf Meter Reading ooo'Jlo TYP,11 of Service: (check one) r!2I' Domestic 0 Fire 00ther m d Remarks (Describe O&fldenci&s: bypasses, ouUets before the device, coonectJons bet'WE!en the device and point or entry, mis.sing or Inadequate alfOap, etc.) y Certttication: This device meets, D does NOT meet, the requirements of an acceptable containment device at the time of testing . . I hereby certify the. foregoing data to be co'.rect., ! . )o\'-"" (TU·. \C\.-\0 zc;, $ J... &/1..•"J ~ 12 IS t 1J,1, Print Name Certified Tester No. .SiQnature ExpiratiOn Date --·--· ~'.~£:;.;::~:~:?~~::::~g;~t).:.:i'.ic~t,~~.~.:11:,:::.~~ .. =~~'.=:~:········ ...... ;Z .. ;.e=~'················· !..Eh~~! .. ~~°.r..: .. z.~.z~ Print Name Tiiie Signature Telephone i@i:i Certttication that installation is In accordance wtth the approved plans. (To be completed by Iha design engina<lr or architect ...,,.,_..... ... _ or water suppher.) I hereby certttiy that this Installation has been made in accordance wtth the approved plans. ,_lN_am_•-----------+-1i-1t1e __________ --l Date rn m rn j Uoonsa Number Phone ( m (r' y i.~.~P.'.".5."~.ti.°.11.............................................................................................................................. . Describe minor installation changes iAddress !ciiY······························· ············ · ···· ···F~;;;;; ····· · · ····· · · · ·· Tzi;; ·· · · · · · ··· · ·· · Signature NYS DOH Log# NOTE: Sand one compktte-0 copy to the de!llgnaled heaJth department reproseniattve and one copy to the water supplier wi!:hln 30 days of testing of !he devle&. DOH-l013 (9191) Notify owner and water supplier Immediately II device falls test and repairs cannot lmmedlatety be made. WHITE .. OFFICE COPY YELLOW · CUSTOMER COPY PINK · NYS DEPARTMENT OF HEALTH CofO Reports/2021-08-31 Fire Alarm System Record of Completion.pdf CofO Reports/2021-08-31 HVAC Air Balance Report.pdf CofO Reports/2021-09-01 Radon Concentration Testing.pdfJanuary 28, 2005 401 PENBROOKE DRIVE  SUITE 3A  PENFIELD, NEW YORK 14526 PHONE 585-388-6616 Seeler Engineering, P.C. September 1, 2021 Mr. Cortland Knopp Architect/Project Manager PLAN Architectural Studio, P.C. 250 South Avenue, Suite 100 Rochester, New York 14604 Re: West End Heights Mixed Use Building – Radon Testing Dear Mr. Knopp: Seeler Engineering, P.C. (Seeler) completed radon testing at the West End Heights Mixed Use Building located at 701 West Court Street, Ithaca, New York 14850 from August 27, 2021 to August 30, 2021. On August 27, 2021, Seeler placed a single radon test kit in the first-floor rooms identified below. The four radon test packets were collected by Seeler on August 30, 2021. The results are summarized below with the laboratory report included as Attachment 1. Radon Concentrations Address Radon Concentration (pCi/l) 701 W. Court Street Room 102 < 0.3 701 W. Court Street Room 104 < 0.3 701 W. Court Street Room 002B < 0.3 701 W. Court Street Room 007 < 0.3 The results from the radon tests show that the radon concentration at the West End Heights Mixed Use Building is below the USEPA Guidance Value of 4.0 pCi/l. If you have any questions, please do not hesitate to contact me at (585) 388-6616 ext. 101 or by email at timseeler@seelerengineering.com. Very truly yours, Seeler Engineering, P.C. Tim A. Seeler, P.E. Principal Attachments: • Attachment 1 – Radon Laboratory Test Reports Cc: Lewis Romano, Senior Superintendent, LeCesse Construction August 31, 2021 ** LABORATORY ANALYSIS REPORT ** Pg 1 of 1 Attention: P6653 / TIM SEELER / SEELER ENGINEERING, P C Kit #: 7331441 Result: < 0.3 pCi/l Location: 1st Floor Brett Marcellin 701 W Court St Rm 102 Ithaca, NY 14850-3216 Analysis Note : Analyzed : 2021-08-31 at 1:00 pm Started : 2021-08-27 at 12:00 pm Ended : 2021-08-30 at 10:00 am Hours/MST% : 70 hours 14.0% 60°F Air Chek 1936 Butler Bridge Rd, Mills River, NC 28759-3892 Phone: (828) 684-0893 Fax: (828) 684-8498 August 31, 2021 ** LABORATORY ANALYSIS REPORT ** Pg 1 of 1 Attention: P6653 / TIM SEELER / SEELER ENGINEERING, P C Kit #: 7331442 Result: < 0.3 pCi/l Location: 1st Floor Brett Marcellin 701 W Court St Rm 104 Ithaca, NY 14850-3216 Analysis Note : Analyzed : 2021-08-31 at 1:00 pm Started : 2021-08-27 at 12:00 pm Ended : 2021-08-30 at 10:00 am Hours/MST% : 70 hours 8.8% 60°F Air Chek 1936 Butler Bridge Rd, Mills River, NC 28759-3892 Phone: (828) 684-0893 Fax: (828) 684-8498 August 31, 2021 ** LABORATORY ANALYSIS REPORT ** Pg 1 of 1 Attention: P6653 / TIM SEELER / SEELER ENGINEERING, P C Kit #: 7331432 Result: < 0.3 pCi/l Location: 1st Floor Brett Marcellin 701 W Court St Rm 002b Ithaca, NY 14850-3216 Analysis Note : Analyzed : 2021-08-31 at 1:00 pm Started : 2021-08-27 at 12:00 pm Ended : 2021-08-30 at 10:00 am Hours/MST% : 70 hours 10.3% 60°F Air Chek 1936 Butler Bridge Rd, Mills River, NC 28759-3892 Phone: (828) 684-0893 Fax: (828) 684-8498 August 31, 2021 ** LABORATORY ANALYSIS REPORT ** Pg 1 of 1 Attention: P6653 / TIM SEELER / SEELER ENGINEERING, P C Kit #: 7331431 Result: < 0.3 pCi/l Location: 1st Floor Brett Marcellin 701 W Court St Rm 7 Ithaca, NY 14850-3216 Analysis Note : Analyzed : 2021-08-31 at 1:00 pm Started : 2021-08-27 at 12:00 pm Ended : 2021-08-30 at 10:00 am Hours/MST% : 70 hours 10.3% 60°F Air Chek 1936 Butler Bridge Rd, Mills River, NC 28759-3892 Phone: (828) 684-0893 Fax: (828) 684-8498 CofO Reports/2021-09-07 Elevator Final Acceptance.pdf CofO Reports/2021-09-14 Water Main Bacteriological Test.pdf