Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Electrical As-Builts
T G G G G G 10' REAR YARD SETBACK10' SIDE YARD SETBACK28.48'7.92 WEST COURT STREET NORTH MEADOW STREETSLAGHT (R.O.) 615/906TAX MAP PARCEL No.59-2-8 CIASCHI (R.O.) 482211-001TAX MAP PARCEL No.59-2-16.1 TOMPKINS COMMUNITY ACTION(R.O.)2500/1900TAX MAP PARCEL No. 59-2-14 PARCEL B CURBCUT C.O. C.O. C.O. C.O. C.O. C.O.WWWWWWDDDDDDCCTVCCTVCCTVCCTVCCTVC C T V VS PC 1" PVC-80, DB (TYP) 3-#2AWG, 15KV SHIELDED COPPER CABLE WITH 175 MIL INSULATION AND 1-#2AWG NEUTRAL IN (2) 4" PVC-80, DIRECT BURIED. TERMINATIONS BY NYSEG. (2) 4" PVC-80, DB FOR TELEPHONE AND CATV 5 SETS OF 4-500KCM IN (6) 4" PVC-80, DB 4 e701 3 e701 - --- 5 e701 3 e701 3 e701 8 e701 UTILITY TRANSFORMER BOLLARD (TYP)11 e701 2 e701 2 e701 1 e701 2 e701 WP WP WP WP WP UNDER CANOPY LU LU LU LU LT LTLTLTLTLT LVPH1/6,8 12 e701 3 e702 #10#10 #10 #10 #10 #10 #10 #10 #10 PROVIDE 2-#8, 1-#10EG IN 1”PVC-80, DIRCT BURIED FOR POWER AND LIGHTING TO UTILITY SHED, TO A 30A/2P CIRCUIT BREAKER IN PANEL LVPH1. TERMINATE CONDUIT AT PANEL AND PROVIDE PULL STRING. 2 e701 #10 1" PVC-80, DB (TYP FOR BOLLARD LIGHTING) 4 e701 3 e701 A6 e100 2 A7 LI 48" GFI WP GFI PROVIDE SURFACE MOUNTED RACEWAY AND OUTLET BOXES AS REQUIRED. WP GFI LO LQ LQ LCS/1 CONNECT VIA PHOTOCELL CONNECT VIA PHOTOCELL LCS LCS/2 plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e100SITE PLAN - ELECTRICALLAKEVIEW HEALTH SERVICES WESTEND HEIGHTS701 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.22.2019 1/16" = 1'-0"1 SITE PLAN - ELECTRICAL N REVISIONS No. Description Date A6 PRIMARY SER CHANGE 04.28.20 A7 SITEWORK & STORAGE SHED 05.15.20201/4" = 1'-0"2 ENLARGED SHED - ELECTRICAL A7 TOTAL EST. DEMAND:3 A TOTAL CONN.:3 A TOTAL EST. DEMAND:615 VA Receptacle 540 VA 100.00% 540 VA TOTAL CONN. LOAD:624 VA Lighting 84 VA 90.00% 75 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:5 A 0 A TOTAL LOAD:624 VA 0 VA 7 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 8 5 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 6 3 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 4 1 SHED LTG 20 A 1 0.1 0.5 1 20 A SHED RECEPT 2 CKT CIRCUIT DESCRIPTION TRIP POLES A (kVA)B (kVA)POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LCS LVPH1 100 A 1Ø, 3W 120/208... SURFACE 10 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE: PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD A7 SHED F F F F F F F S S S SS VS S OS-A OS-A OS-B OS-B OS-B OS-B OS-BSSSS VSH TVCCTV CCTV CCTVCCTV S S/CO S S S CCTVCCTVCOCO CO CO COM M MS DTS MSFS S D S D SD SD DTS DTSVS MSM MMS 200 CORRIDOR A02 STAIR A 215 TRASH / RECYCLE E01 ELEVATOR 200A RECEPTION LOUNGE e601 3 e601 2 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 1 e601 e601 1 48" AOR AUX 202 (TYPE 4) 1-BEDROOM APARTMENT 201 (TYPE 3) 1-BEDROOM APARTMENT 203 (TYPE 2) 1-BEDROOM APARTMENT 204 (TYPE 2) 1-BEDROOM APARTMENT 206 (TYPE 2) 1-BEDROOM APARTMENT 205 (TYPE 2) 1-BEDROOM APARTMENT 207 (TYPE 2) 1-BEDROOM APARTMENT209 (TYPE 2) 1-BEDROOM APARTMENT 208 (TYPE 2) 1-BEDROOM APARTMENT210 (TYPE 2) 1-BEDROOM APARTMENT 212 (TYPE 2) 1-BEDROOM APARTMENT 213 (TYPE 2) 1-BEDROOM APARTMENT 200 CORRIDOR TR TR TR TR TR TRTRTR 8'-0" AFF CL 8'-0" AFF CL 8'-0" AFF CL 8'-0" AFF CL LG LG LHLH LG X2 X1 LG LGX2LG LG LGLGLGLGLGLGLGLGLGLGLGLGLG LH LH LG LG LG 216 I.T. CLOSET 217 CUST. LK LK LK LK 7 1 1 1 1 X1 LI 214 (TYPE 2) 1-BEDROOM APARTMENT B02 STAIR B C02 CHASE 211 (TYPE 2) 1-BEDROOM APARTMENT H/VI PANIC PUSHBUTTON REPEATER FCU-9 e601 4 (TYP FOR 2ND AND 4TH FLOOR ONLY) A/VB A/VB 9 9 2 2 9 99 2 2 9 3 3 4 4 4 4 1 e801 5 LVPH1/20 LVPH1/4 6 18 EF-3 LVPEM/5 8 TOP OF 5TH FLOOR STAIRWELL ONLY PROVIDE (1) DUCT TEST STATION ON 5TH FLOOR ONLY FOR DOAS UNIT 43 1 2 3 4 5 6 7 8 10 11 12 1413 16 A C D E F G H I A.5 B 7.6 B.1 15.5 15.6 H.3 9 5TH FLR ONLY 10 PROVIDE (2) DUCT TEST STATIONS ON EACH FLOOR FOR SMOKE DAMPER DUCT DETECTORS E.10 LVPLS/98'-0" AFF CL LI EF-3 48 48" AOR 1 e801 300 CORRIDOR 2 3 4 A C D A.5 B B.1 B03 STAIR B 316 I.T. CLOSET BCC-332 E.10 317 CUST. plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e103TYPICAL FLOORS 2 - 5 - ELECTRICAL LAKEVIEW HEALTH SERVICES WESTEND HEIGHTS709 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.22.2019 1/8" = 1'-0"1 TYPICAL SECOND THRU FIFTH FLOOR PLAN - ELECTRICAL e103 ELECTRICAL DRAWING NOTES 1 PROVIDE EXIT SIGN AND CONNECT TO A 20A/1P CIRCUIT BREAKER IN PANEL LVPLS/2 USING 2-#12, 1-#12EG IN 1/2" CONDUIT. LOCK CIRCUIT BREAKER IN ON POSITION. 2 CONNECT LUMINAIRE TO LIFE SAFETY BRANCH CIRCUIT IN PANEL LVPLS, CIRCUIT 4. 3 ON SECOND AND FOURTH FLOORS ONLY, PROVIDE 120VAC, SMOKE DETECTOR IN BEDROOM AND COMBINATION SMOKE AND CO DETECTOR OUTSIDE BEDROOM, WITH AUDIBLE AND VISUAL BASE AND BATTERY BACK-UP. CONNECT BRANCH CIRCUIT TO THE LIGHTING CIRCUIT AHEAD OF ALL SWITCHING. PROVIDE WIRING BETWEEN THE DEVICES SUCH THAT IF ONE DEVICES GOES INTO ALARM, ALL AUDIBLE AND VISUAL BASES WILL SOUND. 4 ON SECOND AND FOURTH FLOORS ONLY, MOUNT DOORBELL WITH STROBE AT 80" ABOVE FINISHED FLOOR TO BOTTOM OF BOX. CONNECT TO DOORBELL PUSHBUTTON. 5 CONNECT TO LVP4/ CIRCUIT 1 FOR 3RD FLOOR, CIRCUIT 3 FOR 4TH FLOOR, AND CIRCUIT 5 FOR 5TH FLOOR RECEPTACLE CIRCUITS. 6 CONNECT TO LVP4 CIRCUIT 2 FOR 3RD, 4TH, AND 5TH FLOORS LIGHTING CIRCUIT. 7 PROVIDE 4" SLEEVE ABOVE ACCESSIBLE CEILING SPACE. FIRE STOP AS REQUIRED. 8 CONNECT TO LVPEM/ CIRCUIT 7 FOR 3RD FLOOR, CIRCUIT 9 FOR 4TH FLOOR, AND CIRCUIT 11 FOR 5TH FLOOR RECEPTACLE CIRCUITS. 9 CONNECT LUMINAIRE TO LIFE SAFETY BRANCH CIRCUIT IN PANEL LVPLS, CIRCUIT 6. 10 LOCATION OF SMOKE DAMPER PROVIDED BY DIVISION 23. PROVIDE120 VOLT BRANCH CIRCUIT FROM LVPLS1/35 AND CONNECT THE SMOKE DAMPER. PROVIDE A FIRE ALARM CONTROL MODULE TO CONTROL THE DAMPER. WIRE THE DAMPER SUCH THAT IT IS POWERED ON. FURNISH DUCT DETECTOR AND PROVIDE DUCT TEST STATION. WIRE TO FIRE ALARM SYSTEM. N 1/8" = 1'-0"2 PARTIAL THIRD FLOOR PLAN - ELECTRICAL # H M M M S S S D EG-1 LH GFI LS X3 WP TOP OF SHAFT LH LH ODU-1 WP GFILS 8'-0" AFF CL 8'-0" AFF CL 22 DOAS-1 1 LVPLS/3 LVPLS/26,28,30 1 LVPLS/5 30AF 30AS60AF 60AS 10 e701 6 7 WP 6 e702 GFI WP 3 2 2 BLOCK HEATER AND BATTERY CHARGER LVPH4/5 1 2 3 4 5 6 7 8 10 11 12 1413 16 A C D E F G H I A.5 B 7.6 B.1 15.5 15.6 H.3 9 RADON FAN. COORDINATE EXACT LOCATION WITH ARCHITECT (TYP) RADON FAN. RADON FAN. RADON FAN. RADON FAN. LVPH4/6 LVPH4/6 LVPH4/6 LVPH4/6 LVPH4/8 LVPH4/8 LVPH4/8 E.10 plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e104ROOF PLAN - ELECTRICAL LAKEVIEW HEALTH SERVICES WESTEND HEIGHTS709 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.22.2019 1/8" = 1'-0"1 ROOF PLAN - ELECTRICAL e104 ELECTRICAL DRAWING NOTES 1 PROVIDE EXIT SIGN AND CONNECT TO A 20A/1P CIRCUIT BREAKER IN PANEL LVPLS/2 USING 2-#12, 1-#12EG IN 1/2" CONDUIT. LOCK CIRCUIT BREAKER IN ON POSITION. 2 CONNECT LUMINAIRE TO LIFE SAFETY BRANCH CIRCUIT IN PANEL LVPLS, CIRCUIT 4. 3 CONNECT TO FIFTH FLOOR CORRIDOR RECEPTACLE CIRCUIT. # N TV TV IC 3D 3DF F SD PP S S MMS M MSF S 3 3D F F TV TV D S S PP MS M 3D3IC F M MSTV TV S 33D S S F PP F 3D 3D ICF MS M M MS VSS 207 (TYPE 2) 1-BEDROOM APARTMENT 44" GFI TR 48" 44" GFI TR 44" GFI TR 44" GFI TR 44" TR GFI A 44" TR TR TR TR TR TR TR TR TR TR TR TR TR LC202 LC LC LC LA LC LA LA LC LA LB 1 2 2 3 3 EF-1 VRP-12KA 4 5 7AB AB 8 8 910 LC202/1LC202/3 LC202/4 LC202/7 LC202/6 LC202/8,10 a,b a 7 15 LF d ed e f fdLA EQEQEQEQEQ EQ EQ EQ S LC202/2 F/L b LE LC202/5 2 3 6 LF LC202/9,11 7 8 D E F 7.6 9 A 48" 44" TR44" TR GFI 44" GFI TR 44" GFI TR 44" GFI TR 44" GFI TR TR TR TR TR TR TR TR TR TR TR TR TR TR LA LBLC LC LC LA LA LA LC LC213 1 2 3 4 5 7 8 9 10 AB 8 AB 3 2 VRP-12KA LC213/4 LC213/5 LC213/6 LC213/8,10 202 (TYPE 4) 1-BEDROOM APARTMENT b,c b LF 6 15 LA EQ EQ EQEQe e EQ EQ EQEQEQEQEQ EQ a a e a LC213/3 LC213/2 f f c LC213/7 LE S EF-1 2 3 LF 7 F/L LC213/1 LC213/9,11 1413 16 G H I 15.5 15.6 H.3 48" TR 44" GFI TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR 44" GFI TR 44" GFI TR 44" GFI TR A 44" TR LA LC LA LB LCLC LA LC LC214 LA 1 2 3 4 5 7 8 9 10 AB AB 8 2 3 LC214/2 LC214/3 LC214/4 LC214/5 LC214/6 LC214/7 LC214/8,10 LC214/9 201 (TYPE 3) 1-BEDROOM APARTMENT LF 7 15 c,d c 44" GFI TR LA 5' - 8 3/32"8' - 0"5' - 9 21/32"6' - 11 1/2"6' - 8 1/4"EF-1 VRP-12KA LC214/1 a a a b f bf d LE b F/L S 6 LF 2 3LC214/11,13 LA 11 12 13 F G H I H.3 48" 48" 48" 48" 48" 48" LI ¼" X 2" X 12" GROUND BAR AT 7'-0" AFF 4 e702 5 e702 11 216 I.T. CLOSET 12 LVPH4 13LVPLS/6 14 PROVIDE WALL MOUNTED DATA EQUIPMENT CABINET ON EACH FLOOR LVPEM/15 LVPEM/16 2 C plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e601ENLARGED PLANS - ELECTRICAL LAKEVIEW HEALTH SERVICES WESTEND HEIGHTS709 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.22.2019 1/4" = 1'-0"1 ENLARGED UNIT 2 - ELECTRICAL 1/4" = 1'-0"2 ENLARGED UNIT 3 - ELECTRICAL 1/4" = 1'-0"3 ENLARGED UNIT 4 - ELECTRICAL e601 ELECTRICAL DRAWING NOTES 1 PROVIDE LOAD CENTER. MOUNT AT 48" AFF TO THE TOP OF THE LOAD CENTER. 2 AT EACH APARTMENT VOICE/DATA OUTLET, PROVIDE (2) CATEGORY 6 VOICE CABLES BACK TO THE APARTMENT MECHANICAL ROOM FOR VOICE/DATA. TERMINATE ON THE WALL MOUNTED PATCH PANEL. PROVIDE ALL TESTING, AND LABELING. PROVIDE COVER PLATE. 3 AT EACH TELEVISION OUTLET, PROVIDE (1) RG6/U CABLE FROM THE OUTLET BOX BACK TO THE SPLITTER LOCATED IN APARTMENT MECHANICAL ROOM. LABEL CABLE. PROVIDE ALL SPLITTERS, TERMINATIONS, AND TESTING. REFER TO CATV RISER DIAGRAM FOR MORE INFORMATION 4 IN EACH APARTMENT MECHANICAL ROOM, PROVIDE 12 PORT PATCH PANEL. PROVIDE (1) CATEGORY 6 CABLE FROM PATCH PANEL, BACK TO ** ROOM 125. TERMINATE THE CABLE AT THE 48 PORT WALL MOUNTED PATCH PANEL FOR VOICE CABLES. PROVIDE ALL TERMINATIONS, TESTING AND LABELING. 5 LOCATION OF SPLITTER IN THE APARTMENT MECHANICAL ROOM, PROVIDED BY SPECTRUM CABLE. PROVIDE RG6/U (MAXIMUM LENGTH OF 150') OR RG11/U (OVER 150' LENGTH) COAXIAL CABLE BACK TO ELECTRIC ROOM 125. LABEL CABLE AT EACH END. TIME WARNER TO PROVIDE ALL TERMINATIONS AND TESTING. 6 PROVIDE 15 CANDELA FIRE ALARM NOTIFICATION APPLIANCE. PREWIRE FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT FROM AOM IN THE CORRIDOR TO JUNCTION BOX FOR FUTURE ADA ADAPTABILITY. REFER TO FIRE ALARM SYSTEM RISER FOR WIRING DETAILS. 7 PROVIDE LOW FREQUENCY, 110 CANDELA FIRE ALARM NOTIFICATION APPLIANCE. PREWIRE FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT FROM AOM IN THE CORRIDOR TO JUNCTION BOX FOR FUTURE ADA ADAPTABILITY. REFER TO FIRE ALARM SYSTEM RISER FOR WIRING DETAILS. 8 PROVIDE 120VAC, MULTIPLE STATION COMBINATION SMOKE DETECTOR, WITH AUDIBLE BASE. CONNECT BRANCH CIRCUIT TO THE LIGHTING CIRCUIT AHEAD OF ALL SWITCHING. PROVIDE WIRING BETWEEN THE DEVICES SUCH THAT IF ONE DEVICE GOES INTO ALARM, ALL AUDIBLE BASES WILL SOUND. 9 PROVIDE TWO SWITCHES TO CONTROL THE HOOD LIGHT AND THE OTHER TO CONTROL THE HOOD EXHAUST FAN. CONNECT THE RANGE HOOD VIA THE KITCHEN RECEPTACLE CIRCUIT. INSTALL IN CABINET VALANCE FACE. PROVIDE STAINLESS STEEL COVER PLATE AND BLACK SWITCHES. IN ADA UNIT, PROVIDE WIRING IN CONDUIT. 10 PROVIDE NEMA 14-50R RECEPTACLE FOR RANGE. PROVIDE 3/C #6 + #10EG TYPE NM CABLE FROM A 50A/2P CIRCUIT BREAKER IN THE APARTMENT PANEL. 11 PROVIDE (2) 4" SLEEVES ABOVE ACCESSIBLE CEILING SPACE. FIRE STOP AS REQUIRED. 12 PROVIDE 4'x8'X3/4" PLYWOOD BACKBOARD AT 6" A.F.F. PAINT WITH 2 COATS FIREPROOF GRAY PAINT. 13 PROVIDE PANEL LVP4 ON FOURTH FLOOR ONLY. 14 PROVIDE 4" CONDUIT BETWEEN EACH FLOOR. 1/4" = 1'-0"4 ENLARGED IT CLOSET - ELECTRICAL N # PVC CONDUIT THREADED CAP ON ALL SPARES TO COUPLING, PULLBOX, PANEL ECT. PVC TO RIGID ADAPTER PROVIDE ENGRAVED NAMEPLATE ON CONDUITFINISHED FLOOR WRAP ALL JOINTS 100% WATERTIGHT SEAL VAPOR BARRIER TO CONDUIT RIGID HOT DIPPED GALVANIZED CONDUIT BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT SAND BED ENVELOPE AS CALLED FOR ON PLANS. WHERE CONDUIT STUBS UP UNDER FLOOR MOUNTED EQUIPMENT SUCH AS SWITCHGEAR, PROVIDE PVC ELBOWS IN LIEU OF RIGID SHOWN. AT EACH CONDUIT STUB-UP, AFFIX ENGRAVED PLASTIC NAMEPLATE INDICATING CONDUIT NO. OR CIRCUIT IDENTIFICATION. ATTACH WITH NYLON CABLE TIE. NOTES: 2 NO SCALE CONDUIT STUB-UP INSIDE BUILDING DETAIL 1. 2. 1 NO SCALE 12" 6'-0" 1 2 4 5 6 7 3 8 9 1 2 3 4 5 6 7 8 9 CONDUIT RISER AT UTILITY POLE DETAIL NOTES: POLE BY UTILITY COMPANY. TERMINATE RACEWAY AT HEIGHT DICTATED BY UTILITY COMPANY. TERMINATE AND CAP SPARE RACEWAY. MINIMUM 3'-0" BELOW GRADE. (2) 4" PVC, SCHEDULE 40 CONDUITS. SANDBED ENVELOPE, MINIMUM 3" COVER ON ALL SIDES. ENCASEMENT SHALL RUN FROM 6'-0" OFF OF POLE TO RACEWAY TERMINATION AT TRANSFORMER PAD. PVC TO RIGID STEEL CONDUIT ADAPTER. (2) 4" GALVANIZED, RIGID STEEL CONDUITS. 90 x 36" RADIUS SWEEP ELBOWS. NO SCALE 3 GENERAL NOTES: 2' VERTICAL COMMON TRENCH SEPERATION DETAIL COMMON TRENCH 600V SERVICE CABLE IN CONDUIT OR DIRECT BURIED OTHER UTILITIES COMMUNICATIONCATV GAS MIN. 8'12" A. B, NO SEWER/WATER/DRAINAGE/BRANCH CIRCUIT WIRING OR CUSTOMER FUEL LINE IN COMMON TRENCH. IF OTHER UTILITIES, SUCH AS CUSTOMER SEWER, WATER, DRAINAGE, BRANCH CIRCUIT WIRING, OR CUSTOMER FUEL LINE, CROSS THE ELECTRIC OR COMMON TRENCH, A MINIMUM 2' OF VERTICAL SEPARATION MUST BE MAINTAINED. 12" 4 NO SCALE DIRECT BURIED CONDUIT DETAIL ONE DUCT 40" MIN. GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE 5 NO SCALE DIRECT BURIED CONDUIT DETAIL TWO DUCTS 40" MIN. 7 1/2" GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE 7 1/2" 40" MIN. 7 1/2" 6 NO SCALE DIRECT BURIED CONDUIT DETAIL THREE DUCTS GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE 7 NO SCALE DIRECT BURIED CONDUIT DETAIL FOUR DUCTS 7 1/2" 40" MIN. 7 1/2" GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT PROVIDE SPACERS TO ENSURE EVENINSTALLATION. 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE 11PROTECTIVE BOLLARD DETAIL SUBGRADE PAINT YELLOW PAVEMENT OR GRADE NO SCALE 3,000 PSI CONCRETE CONCRETE CAP -ROUND OFF TOP 6" DIAMETER SCHEDULE 40 GALVANIZED PIPE FILLED WITH 3,000 PSI CONCRETE 1/2" EXPANSION JOINT FILLER WITH SEAL 4'-0" MIN. 4'-0" MIN. 6" 6"6" 6"2'-0" 2'-0" WP GFI PROVIDE RECEPTACLE AT GENERATOR 4-#10, 1-#10EG, 1" C 28 26 30 TO LVPEM 200A/3P (3) 20A/1P 10 NO SCALE EMERGENCY GENERATOR SCHEMATIC WIRING DIAGRAM JJ DIGITAL CONTROL PANEL (FURNISHED WITH GENERATOR) CONNECT BATTERY CHARGER 2-#12, 1-#12EG, 1/2"C 2-#12, 1-#12EG, 1/2"C (10) #18 SHIELDED TWISTED PAIR IN 1"C OR AS REQUIRED BY MANUFACTURER LVPLS/26 (20A/1P C.B., BLOCK HEATER) LVPLS/28 (20A/1P C.B., BATTERY CHARGER) LVPLS/30 (20A/1P C.B., GFI RECEPTACLE) INSTALL ANNUNCIATOR PANEL FURNISHED WITH GENERATOR. INSTALL IN RECEPTION OFFICE 003 ATS-EM 208Y/120V 200A/3P TO TELEPHONE TERMINAL BLOCK CONNECT BLOCK HEATER (1) #18 SHIELDED TWISTED PAIR IN 1/2 "C FOR GENERATOR START SIGNAL (2) #22 AWG TWISTED PAIR, 3/4 "C (2) ENCLOSED CIRCUIT BREAKERS IN GENERATOR ENCLOSUREEMERGENCY GENERATOR 60KW/75KVA 208Y/120V NATURAL GAS LOCATED ON ROOF PROVIDE EMERGENCY STOP BREAK- GLASS PUSHBUTTON. INSTALL OUTSIDE OF GENERATOR ROOM OR EXTERNAL TO THE WEATHERPROOF ENCLOSURE 2-#14, 1/2"C TO LVPLS ATS-LS 208Y/120V 60A/3P 60A/3P 4-#4/0, 1-#4EG IN 4" C 4-#4, 1-#8EG IN 4"C TOP VIEW SIDE VIEW 9CONCRETE EQUIPMENT PAD DETAIL 6" x 6" 10/10 WIRE MESH FINISH GRADE NO SCALE PAD SHOULD BE A MINIMUM OF 6" LARGER THAN THE EQUIPMENT ENCLOSURE ON ALL SIDES 6" x 6" 10/10 WELDED WIRE MESH PROVIDE 1", 45 DEGREE CHAMFER ON ALL SIDES 3000 PSI CONCRETE EQUIPMENT PAD 4" 6" 12 NO SCALE 6" 42" 2" 30"36" CHAMFER ALL EDGES ELECTRICAL CONDUIT PER SITE PLAN #4 REBARS AT EACH CORNER VERTICAL #3 TIES AT 12" O.C. HORIZONTAL 12" ROUND CONCRETE BASE BY E.C. VERIFY WITH BOLLARD MFGR. FINISHED GRADE BOLLARD WITH LIGHT BASE DETAIL 8 NO SCALE DIRECT BURIED CONDUIT DETAIL SIX DUCTS 40" MIN. 7 1/2" 7 1/2"7 1/2" GRASS AREAS BACKFILL WITH NATIVE MATERIAL IN 6" LIFTS. COMPACT AFTER EACH LIFT. PAVEMENT AREAS BACKFILL WITH #2 CRUSHED STONE IN 6" LIFTS. COMPACT AFTER EACH LIFT. 3" SCREENED TOP SOIL AROUND CONDUIT PROVIDE SPACERS TO ENSURE EVENINSTALLATION. 4" SCREENED TOP SOIL FOR GRASS AREAS. PAVEMENT AS REQUIRED6" WIDE, RED PLASTIC TAPE WITH WORDING "CAUTION BURIED ELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE FINISH GRADE plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e701ELECTRICAL DETAILSLAKEVIEW HEALTH SERVICES WESTEND HEIGHTS709 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.22.2019 1 NO SCALE VAULT TYPE TRANSFORMER PAD DETAIL #2 CRUSHED STONE, 8" DEEP 10'-0" MINIMUM TO BUILDING TRANSFORMER PAD (72"x72") 20"x40" OPENING 5/8"x8' LONG GROUND ROD (TYP OF 4) 2-250 KCM BARE COPPER GROUND WIRE AT 36" BELOW GRADE STANDARD COVER RG&E STANDARD MC-101M OR EQUAL BY QUAZITE RG&E STANDARD MC-100 OR EQUAL BY QUAZITE 5/8"x8' GROUND ROD 6" 6" 9" 4'-0" 2'-2" 6'-0" 6'-0" 6" 1'-4" 3'-4"1'-8" 1'-0" 18" NOTES: VAULT TYPE PADS SHALL BE PRE-CAST CONCRETE OR PRECAST POLYMER CONCRETE, AS PERMITTED BY THE UTILITY. PROVIDE (1) 5/8 " X 8' COPPER GROUND ROD IN CORNER OF VAULT.PROVIDE #2 BARE COPPER GROUND RING TO BE INSTALLED 3' FROM THE VAULT AND BURIED A MINIMUM OF 36" DEEP. ATTACH BOTH ENDS OF THE GROUND RING TO THE GROUND ROD. PROVIDE A MINUMUM OF 3" OF #2 CRUSHED STONE BASE. INSTALL PER UTILITY SPECIFICATIONS. COORDINATE INSTALLATION WITH UTILITY. 1. 2. 3. 4. 5. N L1 L2 L3 GROUND BUS NEUTRAL BUS 2 NO SCALE SERVICE ENTRANCE GROUNDING DETAIL GROUNDING ELECTRODE SYSTEM NOTES: SERVICE ENTRANCE DISCONNECTING MEANS GROUNDED CONDUCTOR SERVICE ENTRANCE CONDUCTORS PROVIDE ELECTRODE CONDUCTOR. PROVIDE INSULATED COPPER CONDUCTOR PER SPECIFICATIONS. IF NO SIZE SPECIFIED, PROVIDE INSULATED COPPER CONDUCTOR SIZED PER N.E.C. TABLE 250-94. INSTALL IN RIGID, SCHEDULE 40, PVC RACEWAY. METAL UNDERGROUND WATER PIPE IN DIRECT CONTACT WITH EARTH FOR 10 FEET OR MORE. SHALL BE SUPPLEMENTED BY ITEMS 3 AND 4. BUILDING STRUCTURAL STEEL. MADE GROUNDING ELECTRODE. REFER TO "MADE GROUNDING ELECTRODE-GROUND GRID" DETAIL AND SPECIFICATIONS. MAIN BONDING CONDUCTOR. PROVIDE INSULATED COPPER CONDUCTOR SIZED PER N.E.C. ARTICLE 250-94. BOND GROUND BUS TO EQUIPMENT ENCLOSURE WITH BARE COPPER BONDING JUMPER SIZED PER N.E.C. ARTICLE 250-79. WATER MAIN FOOTER STEEL GROUND STEEL BUILDING STEEL 1 2 3 4 5 6 1 6 5 4 NO SCALE GROUND BAR ON WALL TWO HOLE COMPRESSION LUG GROUND WIRES BY EQUIPMENT VENDOR GROUND BAR CONNECTION DETAIL DRAWING NOTES: 5 NO SCALE GROUND BAR DETAIL 2" 2" 1" 7/16" DIA. COPPER GROUND BAR, 1/4"x4"x12" (MAIN SERVER RM) OR 1/4"x2"x12" (IT RMS), NEWTON INSTRUMENT CO. OR EQUAL. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. INSULATORS, NEWTON INSTRUMENT CO. CAT. NO. 3061-4 OR EQUAL. 5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. CAT. NO. 3015-8 OR EQUAL. WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT. NO. A-6056 OR EQUAL. 5/8-11 x 1" H.H.C.S. BOLTS, NEWTON INSTRUMENT CO. CAT. NO. 3012-1 OR EQUAL. LONG BARREL DOUBLE HOLE COMPRESSION LUG 3 4 5 1 2 6 1 2 3 4 5 6 GENERAL NOTES: 6 NO SCALE ROOF RECEPTACLE STUB-UP DETAIL GALVANIZED CONDUIT (SIZE AS REQUIRED) WEATHERPROOF DUPLEX RECEPTACLE WITH SPRING-LOADED CAP. KEY LOCKABLE, WEATHER- PROOF ENCLOSURE SHALL BE MARKED "SUITABLE FOR WET LOCATIONS WHILE IN-USE." SEALTIGHT CONNECTOR FLASH AND SEAL ROOF PENETRATION AS REQUIRED TO MAINTAIN ANY ROOF WARRANTEE. PROVIDE THE SERVICES OF A QUALIFIED ROOFING CONTRACTOR. FINISHED FLOOR CEILING AAB12 AAB13 4" MINIMUM 7 NO SCALE FLUSH VOICE/DATA OUTLET INSTALLATION DETAIL PROVIDE 1/2" CONDUIT INSIDE NEW WALL PROVIDE 4 11/16" SQUARE x 2 1/8" DEEP BACKBOX WITH SINGLE GANG MUD RING PROVIDE 2-GANG BACKBOX WITH DOUBLE DUPLEX RECEPTACLE, FLUSH MOUNTED PROVIDE 1" CONDUIT WITH PULLSTRING TO CEILING SPACE WALL CAT 5 SPARE SPARECAT 5 CASE A CASE B CASE C NO SCALE 8TYPICAL CABLE HANGER DETAIL BACKBONE UTP COAX AND FIBER COAX AND FIBER BACKBONE UTP OPTICAL FIBER AND COAX BACKBONE UTP (WHERE APPLICABLE) CAT 5 CABLES (PROVIDE HANGER SIZE AND QUANTITY AS REQUIRED) SPARE HANGER (PROVIDE ONE PER RUN) NOTE: PROVIDE HANGERS IN CONFIGURATIONS OR COMBINATIONS OF CONFIGURATIONS SHOWN AS REQUIRED TO SUIT SITE CONDITIONS IN ALL CASES PROVIDE A SPARE HANGER RUN FOR FUTURE CABLING. 1. FTPANELBOARDDISCONNECTTHERMOSTAT LIGHT SWITCHCARD ACCESSVOICE/DATA OUTLETDUPLEX RECEPTACLE6'-8"6'-0"5'-0" 4'-0"4'-0"4'-0"4'-0"4'-0" 1'-6"1'-6"1'-6" 4'-0" NO SCALE 9TYPICAL DEVICE MOUNTING ELEVATIONS NOTES:FIRE ALARMAUDIO/VISUALAND VISUALDEVICEIN LOCATIONS WHERE SIMILAR DEVICES ARE MOUNTED AT THE SAME HEIGHT, DEVICES SHALL BE PROPERLY "GANGED" AND SHALL HAVE A SINGLE COVER PLATE. IN LOCATIONS WHERE DIFFERENT DEVICES ARE MOUNTED AT DIFFERENT HEIGHTS WITHIN FOUR FEET OF ONE ANOTHER, DEVICES SHALL BE MOUNTED SUCH THAT THEY HAVE A COMMON CENTERLINE. IF THERE ARE THREE OR MORE DEVICES, THE CONTRACTOR SHALL REQUEST A DETAIL FROM THE ARCHITECT. 1. 2.FIRE ALARMPULL STATIONWALL MOUNTEDTELEPHONEDUPLEX RECEPTACLEMECH. ROOM, GARAGESDESK TOP TELEPHONE/CATV OUTLETFINISHED FLOOR 4'-0"APARTMENT LOAD CENTER3 NO SCALE GASKETED HAND HOLE 1" x 45° CHAMFER #3 TIES 12" ON CENTER #6 BARE COPPER GRD. WIRE MECH. COMPR. CONNECTION PVC SCHEDULE 80 CONDUIT GALVANIZED CONDUIT "ELL." (4) #8 VERTICAL REINFORCEMENT BAR 4000 P.S.I. CONCRETE5'-0" MIN. DOWNTO SOLID BEARING1. 2. FINISHED GRADE (PAVEMENT) BOLT OR MECH. COMPR. GROUND WIRE TO POLE PROVIDE IN-LINE BALLAST FUSES. PROVIDE (2) BUSSMANN "TRON" WEATHERPROOF FUSE HOLDERS, CAT# HEB-AB WITH (2) 10A "KTK" FUSES FOR EACH LUMINAIRE. (4)-36" x 1" DIA. ANCHOR BOLTS GALVANIZED STEEL TO PVC CONDUIT CONNECTOR ROUND FORMED CONCRETE BASE 24" DIA. CONCRETE BASE TOP OF POLE BASE TO BE MEASURED FROM ADJACENT PAVEMENT GRADE. CENTER LIGHT POLES IN ISLANDS. OUTSIDE DIMENSIONS OF ISLANDS ARE 9'-0" X 36'-0". NOTES: 5/8" DIA. x 8' COPPERWELD GROUND ROD (LIGHTNING PROTECTION) LIGHT POLE BASE DETAIL POLE BASE SCHEDULE POLE HEIGHT BASE DIAMETER 39' AND UP 30" DIAMETER 30' - 38' 24" DIAMETER 20' - 29'18" DIAMETER 15" DIAMETER19' AND BELOW 6" IN LAWN 2' IN PAVEMENT 16'-0" plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e702ELECTRICAL DETAILSLAKEVIEW HEALTH SERVICES WESTEND HEIGHTS709 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.22.2019 F F F F FFFF S H EC H F TS S H EC S F TS F F H AOM AOM F F COMMON AREA DEVICES ELEV. LOBBY 120V ELEV. LOBBY FACP/ FARPS DIGITAL COMMUNICATOR COMMON AREA DEVICES TWO TELEPHONE LINES S ST AUX AUX AUX 24 VOLT DC GROUND FLOOR SLC RESIDENT UNITS TYP 2ND -5TH FLOORS SLC RESIDENT ROOMS TYP 2ND -5TH FLOORS SLC COMMON AREAS GROUND FLOOR SLC COMMON AREAS TYP 2ND -5TH FLOORS NAC COMMON AREAS GROUND FLOOR NAC COMMON AREAS TO NEXT APT. CO SENSOR, ICP OR END OF LINE 24 VOLT DC TO NEXT APT. CO SENSOR, ICP OR END OF LINE TO NEXT NOTIFICATION DEVICE OR END OF LINE TO NEXT NOTIFICATION DEVICE OR END OF LINE TYPICAL ACCESSABLE APARTMENT CONFIGURATION TYPICAL ACCESSABLE APARTMENT CONFIGURATION 120V ST AUX ELEV. MECH RM SHUNT TRIP ELEV. PIT SHUNT TRIP TO NEXT ADDRESSSABLE DEVICE/MODULE TO NEXT ADDRESSSABLE DEVICE/MODULE LVPLS/1 NO SCALE 1FIRE ALARM RISER DIAGRAM DRAWING NOTES: INSTALL ICP AND AUDIO/VISUAL FIRE ALARM DEVICES IN ACCESSIBLE UNIT ONLY. ALL OTHER UNITS SHALL BE PREWIRED AS INDICATED SUCH THAT FUTURE ADDITION OF REQUIRED DEVICES FOR ACCESSIBLE UNITS IS AVAILABLE. THIS DRAWING IS DIAGRAMMATIC ONLY. FUNCTIONS SHOWN AS HARDWIRED MAY BE ACCOMPLISHED THROUGH THE USE OF INTELLIGENT DEVICES AND SOFTWARE. 1. NOTES: 1 11 1 11 1 F F LOW FREQUENCY LOW FREQUENCY REMOTE ANNUNCIATOR S TV TV T A T TV TV TV T T TV NO SCALE CATV SYSTEM RISER DIAGRAM 5 RG6/U DROP CABLE (TYPICAL) 8-PORT DIRECTIONAL TAP (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) WALL MOUNT TAPS IN APARTMENT MECHANICAL CLOSET 2ND FLOOR CATV SPLITTER BY CATV COMPANY RG11/U BACKBONE CABLE GROUND FLOOR WALL MOUNTED BROADBAND AMPLIFIER BY CATV COMPANY 4" PVC-80, DIRECT BURIED FOR CATV. REFER TO SITE PLAN FOR MORE INFORMATION RG6/U DROP CABLE (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) TELE/DATA LOCATED IN SERVER 008 TYPICAL APARTMENT TYPICAL APARTMENT COMMUNITY ROOM LOUNGE BR1LR BR1LRS S TV TV T T TV WALL MOUNT TAPS IN APARTMENT MECHANICAL CLOSET RG6/U DROP CABLE (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) TYPICAL APARTMENT LOUNGEBR1LR S S 3RD FLOOR TV TV T T TV WALL MOUNT TAPS IN APARTMENT MECHANICAL CLOSET RG6/U DROP CABLE (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) TYPICAL APARTMENT LOUNGEBR1LR 4TH FLOOR TV TV T T TV WALL MOUNT TAPS IN APARTMENT MECHANICAL CLOSET RG6/U DROP CABLE (TYPICAL) RG11/U BACKBONE CABLE (TYPICAL) TYPICAL APARTMENT LOUNGEBR1LR 5TH FLOOR NO SCALE 2INTERCOM WIRING DIAGRAM 120 VOLTS ENTRY PANEL AUDIO LINE, 485 BUS AND LOW VOLTAGE POWER TRANSFORMER TWISTED PAIR MASTER STATION LOCATED IN RECEPTION/SECURITY OFFICE ENTRY PANEL LOCATED AT FRONT DOOR DOOR STRIKE SUITE STATION SUITE STATION SUITE STATION MASTER STATION NO SCALE 3LIGHTING CONTROL PANEL WIRING DIAGRAM CATEGORY 5 CABLE (TYPICAL) BLDG MTD SIGN LIGHTING CONTROL PANEL ANALOG PHONE LINE LVPLS/10 SITE POLE LTG LCD BLUE BOX LT PANEL WITH INTEGRAL TIME CLOCK LCD PHOTOCELL CONTROL OUTPUT COMMON +24V dc POWER PACK LINE NEUTRAL 120V CONTROL OUTPUT COMMON +24V dc CONTROL OUTPUT COMMON +24V dc LOAD-a LOAD-b NO SCALE OCCUPANCY SENSOR DETAIL 4 CEILING MOUNTED OCCUPANCY SENSOR ADDITIONAL CEILING MOUNTED OCCUPANCY SENSOR AS REQUIRED 3-WAY SWITCH a WALL SWITCH b PROVIDE 3-WAY AND/OR DUAL LEVEL SWITCHING AS CALLED FOR ON PLANS 3-WAY SWITCHWALL SWITCH ADDITIONAL CEILING MOUNTED OCCUPANCY SENSOR AS REQUIRED plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e703ELECTRICAL WIRING DIAGRAMS LAKEVIEW HEALTH SERVICES WESTEND HEIGHTS709 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.22.2019 NO SCALE ELEVATOR POWER WIRING DIAGRAM 3 S S SH SS M N ELEVATOR SHAFT SMOKE HATCH TO ELEVATOR CONTROLLER GROUND FLOOR LOBBY SMOKE DETECTOR ELEVATOR CONTROLLER ELEVATOR WIRING BY ELEVATOR SUPPLIER TO NEAREST 120V RECEPTACLE CIRCUIT ST HH ELEVATOR SHAFT HEAT DETECTOR (BOTTOM) ELEVATOR SHAFT HEAT DETECTOR (TOP) ST 60A/3P 2ND FLOOR LOBBY SMOKE DETECTOR ELEVATOR SHAFT SMOKE DETECTOR LVPHP 20A/1P NOTES: 1.THIS DRAWING IS DIAGRAMMATIC ONLY. FUNCTIONS SHOWN AS HARDWIRED MAY BE ACCOMPLISHED THROUGH THE USE OF INTELLIGENT DEVICES AND SOFTWARE. TO ELEVATOR CONTROLLER TO ELEVATOR CONTROLLER S 3RD FLOOR LOBBY SMOKE DETECTOR GROUND FLOOR LOBBY SMOKE DETECTOR ELEVATOR CONTROLLER SHUNT TRIP CIRCUIT BREAKER AUXILIARY CONTACT 60A/3P FUSED SWITCH WITH 60 AMP FUSES AND ELECTRICAL INTERLOCK KIT. LOCATE AS SHOWN ON PLANS. PROVIDE 2-#12 IN ½"C TO ELEVATOR CONTROLLER 60A FUSIBLE DISCONNECT SWITCH ELECTRICAL INTERLOCK KIT 60A NON-FUSIBLE ELECTRICAL INTERLOCK KIT 2-#12 IN ½"C 3-#4, 1-#4EG IN 1 ¼"C 60A NON FUSED SWITCH WITH ELECTRICAL INTERLOCK KIT. LOCATE AT TOP OF ELEVATOR SHAFT. PROVIDE 2-#12 IN ½"C TO ELEVATOR CONTROLLER 60A/3P SHUNT TRIP CIRCUIT BREAKER WITH AUXILIARY CONTACT. PROVIDE 2-#12 IN ½"C TO ELEVATOR CONTROLLER S 4TH FLOOR LOBBY SMOKE DETECTOR S 5TH FLOOR LOBBY SMOKE DETECTOR 13141516121110987654321 2419171821202223 25262728 2930 40353231333437363839 44414243 46454748 13141516121110987654321 2419171821202223 25262728 2930 40353231333437363839 44414243 46454748 2 4 1 1 1 3 3 1 2 3 4 5 5 WALL CABINET 48 PORT FIBER HORIZONTAL WIRE MANAGEMENT WALL EQUIPMENT RACK 48 PORT CATEGORY 6 PATCH PANEL 48 PORT OPTICAL FIBER PATCH PANEL DATA A DATA B NO SCALE TELE/DATA RACK ELEVATION 1 (6) OUTLET SURGE PROTECTED POWER STRIP RACK/CABINET ELEVATIONS EQUIPMENT SCHEDULE SERVER ROOM 13141516121110987654321 2419171821202223 25262728 2930 40353231333437363839 44414243 46454748 13141516121110987654321 2419171821202223 25262728 2930 40353231333437363839 44414243 46454748 2 6 1 1 1 3 3 5 WALL CABINET 12 PORT FIBER DATA A DATA B TYP 2 - 5 IT ROOM 6 12 PORT OPTICAL FIBER PATCH PANEL GROUND FLOOR 0' -0" HOUSE AND HORIZON METERS 200A METER CHANNEL, 3 PH, 4 WIRE 1600A/3P MAIN CIRCUIT BREAKER 208Y/120 VOLTS, 3 PHASE, 4 WIRE INPUT, SERVICE ENTRANCE RATED PROVIDE 100 AMPERE RATED ALUMINUM TYPE SE CABLE FROM EACH METER CHANNEL TO THE RESPECTIVE APARTMENT LOAD CENTER. VERIFY CABLE ROUTING IN THE FIELD. COORDINATE SERVICE ENTRANCE WITH NYSEG FIVE-CHANNEL METER SECTION WITH 100A/2P MAIN CIRCUIT BREAKERS (25 METERS TOTAL) FIVE-CHANNEL METER SECTION WITH 100A/2P MAIN CIRCUIT BREAKERS (35 METERS TOTAL) 5 2 NO SCALE FIBER OPTIC WIRING DIAGRAM 6 STRAND MULTIMODE FIBER 13141516 12 11 10 9 8 7 6 5 4 3 2 12419171821202223 252627282930403532313334373638394441424346454748 48 PORT FIBER OPTIC PATCH PANEL 13141516 12 11 10 9 8 7 6 5 4 3 2 12419171821202223 252627282930403532313334373638394441424346454748 12 PORT FIBER OPTIC PATCH PANEL 2ND FLOOR IT RM 1ST FLOOR SERVER RM 008 13141516 12 11 10 9 8 7 6 5 4 3 2 12419171821202223 252627282930403532313334373638394441424346454748 12 PORT FIBER OPTIC PATCH PANEL 13141516 12 11 10 9 8 7 6 5 4 3 2 12419171821202223 252627282930403532313334373638394441424346454748 12 PORT FIBER OPTIC PATCH PANEL 13141516 12 11 10 9 8 7 6 5 4 3 2 12419171821202223 252627282930403532313334373638394441424346454748 12 PORT FIBER OPTIC PATCH PANEL 3RD FLOOR IT RM 4TH FLOOR IT RM 5TH FLOOR IT RM /// /// /// /// /// /// /// /// /// /// /// /// // Communication Line ////// ////// ////////// ////////# Note : Power wiring, breaker size, and disconnects should follow local code and NEC. Multi-frame outdoor units require a separate power connection for each frame. Refer to the most up-to-date submittal sheets for applicable electrical data. MCA : 63.2 MOP : 80 V,Hz : 3Phase/208~230V/60Hz ARUM241BTE5 Combi. : ARUM241BTE5 Additional Refrigerant : 42.43 lbs PRHR023A (BCC-4) RLA : 0.06 ARNU183M2A4 (#FCU-12) PREMTBVC0 RLA : 2.30 ARNU243M2A4 (#FCU-10) PREMTBVC0 RLA : 2.30 PRHR023A (BCC-3) RLA : 0.06 ARNU183M2A4 (#FCU-09) PREMTBVC0 RLA : 2.30 ARNU183M2A4 (#FCU-11) PREMTBVC0 RLA : 2.30 PRHR043A (BCC-2) RLA : 0.06 ARNU073M2A4 (#FCU-01) PREMTBVC0 RLA : 2.30 ARNU123M2A4 (#FCU-02) PREMTBVC0 RLA : 2.30 ARNU073M2A4 (#FCU-03) PREMTBVC0 RLA : 2.30 ARNU423M2A4 (#FCU-05) PREMTBVC0 RLA : 2.30 PRHR043A (BCC-1) RLA : 0.06 ARNU243M2A4 (#FCU-06) PREMTBVC0 RLA : 2.30 ARNU183M2A4 (#FCU-04) PREMTBVC0 RLA : 2.30 ARNU183M2A4 (#FCU-07) PREMTBVC0 RLA : 2.30 ARNU543M3A4(#FCU-08) PREMTBVC0 RLA : 2.50 Total RLA : 28.28 BY EC BY MC plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e704ELECTRICAL WIRING DIAGRAMS LAKEVIEW HEALTH SERVICES WESTEND HEIGHTS709 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.22.2019 1/4" = 1'-0"4 ELECTRIC SERVICE ELEVATION 1/8" = 1'-0"5 MULTI V5_DIAGRAM - ELECTRICAL MOTOR RATED SWITCH MANUAL MOTOR STARTER MANUAL MOTOR STARTER WITH RELAY MAGNETIC STARTER COMBINATION MAGNETIC STARTER VARIABLE FREQUENCY DRIVE COMBINATION TWO SPEED MAGNETIC STARTER COMBINATION REDUCED VOLTAGE MAGNETIC STARTER DUPLEX CONTROLLER WITH ALTERNATION CIRCUIT PACKAGED CONTROL UNIT H-O-A SELECTOR SWITCH IN COVER PILOT LIGHT IN COVER REMOTE START-STOP PUSHBUTTONS FIRE ALARM FAN SHUTDOWN LINE-VOLTAGE THERMOSTAT MOTOR STARTER/CONTROLLER NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. PROVIDE 120 VOLT CIRCUIT FROM LVPH1 AND CONNECT AQUASTAT AND TIME SWITCH. CONNECT VIA WALL MOUNTED OCCUPANCY SENSOR SUCH THAT WHEN OCCUPANCY IS SENSED, FAN TURNS ON. DUCT SMOKE DETECTOR TO BE FURNISHED BY ELECTRICAL CONTRACTOR, INSTALLED BY HVAC CONTRACTOR AND WIRED BY ELECTRICAL CONTRACTOR. MECHANICAL EQUIPMENT IS NOT SHOWN ON PLANS. 2ND FLOOR LOCATION IS TYPICAL FOR FLOORS 3 THROUGH 5. REFER TO PARTIAL THIRD FLOOR PLAN FOR LOCATION OF BCC-4 ON FIFTH FLOOR. REFER TO DETAIL 3/e704. PROVIDE BRANCH CIRCUIT TO HPU-1 THEN WIRE FROM HPU-1 TO IFCU-1. PROVIDE MOTOR RATED SWITCH AT EACH UNIT. NOTES: 1. 2. 3. 4. 5. 6. 7. NO SCALE AREA OF RESCUE RISER DIAGRAM 1 plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e801ELECTRICAL SCHEDULESLAKEVIEW HEALTH SERVICES WESTEND HEIGHTS701 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.22.2019 LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION LUMENS LAMP VOLTAGE DESIGN MAKE ACCEPTABLE MANUFACTURERMANUFACTURER MODEL NO. EM1 WALL MOUNTED, DECORATIVE, LED TWO-HEAD EMERGENCY BATTERY PACK WITH SELF DIAGNOSTICS AND TESTING 1300 (2) 6 WATT LED 120 EVENLIGHT LIGHTING TEBL6W-SD APPROVED EQUAL LA 16" DIAMETER SURFACE MOUNTED DECORATIVE LED LUMINAIRE WITH FROSTED ACRYLIC GLASS LENS AND FINISH COLOR BY ARCHITECT. 2000 28 WATT LED, 3000K 120 ROYAL PACIFIC LIGHTING 4327D-30-BN-3K APPROVED EQUAL LB 26" X 5" OVER MIRROR LED LUMINAIRE WITH MATTE WHITE DIFFUSER AND SATIN NICKEL FINISH 1625 13 WATT LED, 3000K 120 OXYGEN LIGHTING 3-5134-24 APPROVED EQUAL LC 2' SURFACE MOUNTED LED LUMINAIRE WITH ACRYLIC LENS AND WHITE HOUSING. 2200 18 WATT LED, 3000K 120 METALUX LIGHTING 2SNLED LED5 LN22 UNV LP830 CD1 APPROVED EQUAL LE 24" LONG UNDER CABINET LED LUMINAIRE WITH ACRYLIC LENS, WHITE HOUSING AND SELECTABLE COLOR TEMPERATURE. PROVIDE ALL REQUIRED MOUNTING HARDWARE. 627 11.1 WATT LED, 120 HALO LIGHTING HU30 SCT 24 P APPROVED EQUAL LG 2' X 2', RECESSED VOLUMETRIC LED TROFFER WITH 3400 LUMENS, SMOOTH ACRYLIC DIFFUSER, SUITABLE FOR GRID INSTALLATION 3400 25.8 WATT LED, 3500K 120 METALUX LIGHTING 22CZ2-34HE-S-UNV-L835-C D1 APPROVED EQUAL LH 4', WALL MOUNTED LED LUMINAIRE WITH FROSTED ACRYLIC LENS, WHITE HOUSING, BI LEVEL DIMMING, AND INTEGRAL OCCUPANCY SENSOR. 3696 30 WATT LED, 3500K 120 INDUSTRIAL LIGHTING PRODUCTS CV4 30WLED UNIV 35 FRAL WHP USBD/HL APPROVED EQUAL LI 4', WALL MOUNTED LED LUMINAIRE WITH SQUARE SEMI FROST ACRYLIC LENS AND WHITE HOUSING 4600 35 WATT LED, 3500K 120 METALUX LIGHTING 4SNLED LED5 SLN46SL UNV L835 CD1 APPROVED EQUAL LJ 12' LINEAR PENDANT LED LUMINAIRE WITH LOW PROFILE, MICROGLOW LENS, AND COLOR BY ARCHITECT. VERIFY HEIGHT ABOVE FLOOR WITH ARCHITECT. 1000LM/FT 108 WATT LED, 3500K 120 FOCAL POINT LIGHTING FTWLS-MG-1000LF-35K-1C -UNV-LD1-J48-DC-**-12' APPROVED EQUAL LK 4" X 4' LINEAR RECESSED LED LUMINAIRE WITH FLUSH SATIN LENS AND SUITABLE FOR INSTALLATION IN WOOD CEILING. COORDINATE TRIM WITH ARCHITECT. 3500 43 WATT LED, 3500K 120 FOCAL POINT LIGHTING FSM4L-FL-875LF-35K-1C-U NV-LD1-TFW-XX-4' APPROVED EQUAL LL 2' X 4', RECESSED VOLUMETRIC LED TROFFER WITH 5500 LUMENS, SMOOTH ACRYLIC DIFFUSER, SUITABLE FOR GRID INSTALLATION 5500 43.5 WATT LED, 3500K 120 METALUX LIGHTING 24CZ2-55HE-S-UNV-L835-C D-1 APPROVED EQUAL LM 2' X 4', RECESSED VOLUMETRIC LED TROFFER WITH 6500 LUMENS, SMOOTH ACRYLIC DIFFUSER, SUITABLE FOR GRID INSTALLATION 6500 48.9 WATT LED, 3500K 120 METALUX LIGHTING 24CZ2-65HE-S-UNV-L835-C D-1 APPROVED EQUAL LN 2' X 4', RECESSED VOLUMETRIC LED TROFFER WITH 7000 LUMENS, SMOOTH ACRYLIC DIFFUSER, SUITABLE FOR GRID INSTALLATION 7000 51 WATT LED, 3500K 120 METALUX LIGHTING 24CZ2-70HE-S-UNV-L835-C D-1 APPROVED EQUAL LO EXTERIOR WALL MOUNTED LED LUMINAIRE WITH UP AND DOWNLIGHT DISTRIBUTION, GLASS DIFFUSER, AND COLOR BY ARCHITECT 22 WATT LED, 4000K 120 PERFORMANCE IN LIGHTING USA QUASAR 20 DOUBLE TECH 22W 4000K 0-10V ** APPROVED EQUAL LP 4IN SQUARE LED DOWNLIGHT WITH 1500 LUMENS, HAZE REFLECTOR AND SUITABLE FOR GRID OR DRYWALL INSTALLATION. 1500 13.4 WALL LED, 3500K 120 HALO LIGHTING PRS4FS15D010-SM4128FS- 44SMDHTIR4SMD APPROVED EQUAL LQ 6IN SQUARE LED DOWNLIGHT WITH 1500 LUMENS, HAZE REFLECTOR, IC RATED, AND 1500 13.4 WATT LED, 4000K 120 HALO LIGHTING PRS615-D010-SM6128FS-6 1SMDHTIR6SMD APPROVED EQUAL LS EXTERIOR WALL MOUNTED LED LUMINAIRE WITH SLIM, LOW PROFILE, AND INTEGRAL PHOTOCELL 4000 38 WATT LED, 4000K 120 LUMARK LIGHTING XTOR4B-W-**-PC1 APPROVED EQUAL LT 39 3/8" HIGH LED BOLLARD WITH SYMMETRICAL, 360 DEGREE DISTRIBUTION, AND FINISH COLOR BY ARCHITECT. 627 18.4 WATT LED, 4000K 208 BEGA LIGHTING 99570-K4-** APPROVED EQUAL LU SINGLE HEAD LED POLE MOUNTED LUMINAIRE WITH TYPE III DISTRIBUTION ON 16' SQUARE STEEL POLE. FINISH COLOR BY ARCHITECT. 5610 55 WATT LED, 4000K 208 BEACON LIGHTING VPS/24NB-55/4K/T3/UNV/ RA/** APPROVED EQUAL X1 SINGLE FACED UNIVERSAL MOUNT LED EXIT SIGN WITH WHITE THERMOPLASTIC HOUSING, GREEN LETTERS, AND REMOVABLE CHEVRONS - 2 WATT LED 120 EVENLIGHT LIGHTING TLX AC GU W APPROVED EQUAL X2 DUAL FACED UNIVERSAL MOUNT LED EXIT SIGN WITH WHITE THERMOPLASTIC HOUSING, GREEN LETTERS, AND REMOVABLE CHEVRONS - 2 WATT LED 120 EVENLIGHT LIGHTING TLX AC GU W APPROVED EQUAL X3 SINGLE FACED UNIVERSAL MOUNT LED EXIT SIGN WITH WHITE THERMOPLASTIC HOUSING, GREEN LETTERS, AND REMOVABLE CHEVRONS. SUITABLE FOR WET LOCATION - 2 WATT LED 120 EVENLIGHT LIGHTING TWL AC G 1U W CW APPROVED EQUAL ELECTRIC EQUIPMENT SCHEDULE ITEM NO. NAME ROOM LOCATION HP KW PH VOLTS PANEL CIRCUIT NUMBER CIRCUIT BREAKER WIRING FROM PANEL TO CONTROL UNIT WIRING FROM CONTROL UNIT TO EQUIPMENT DISCONNECT SWITCH DISCONNECT SWITCH MOTOR STARTER/ CONTROLLER NOTES CONTROLLER LOCATION NEMA RATING NOTESSWITCH AMPS FUSE SIZE 1 ELEV-1 ELEVATOR SHAFT 3 208 LVPEM 38,40,42 60A/3P SHUNT TRIP 3-#6, 1-#10EG IN 1”C 3-#6, 1-#10EG IN 1”C 60 60 10 AU 1 6 2 HW-3 MECH AND ELEC 010 0.6 1 120 LVPH1 43 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 3 HW-2 MECH AND ELEC 010 0.6 1 120 LVPH1 45 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 HW-1 MECH AND ELEC 010 0.6 1 120 LVPH1 46 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 5 HWRP-1 MECH AND ELEC 010 1 1 208 LVPH1 48,50 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 1 6 DOAS-1 ROOF 19.8 3 208 LVPH4 14,16,18 70A/3P 3-#4, 1-#8EG IN 1¼"C 3-#4, 1-#8EG IN 1¼"C 10, 14 AU 3R 3 7 ODU-1 ROOF 23.0 3 208 LVPH4 11,13,15 80A/3P 3-#4, 1-#8EG IN 1¼"C 3-#4, 1-#8EG IN 1¼"C 10 AU 3R 10 FCU-1 ELMSHADE OFFICES 006 0.5 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 11 FCU-2 SUPPORTING HOUSING OFF 002E 0.5 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 12 FCU-3 SHARED COPY/FILES 004 0.5 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 13 FCU-4 CORRIDOR 100C 0.5 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 14 FCU-5 LAUNDRY 017 0.5 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 15 FCU-6 LAUNDRY 017 0.5 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 16 FCU-7 STAFF BREAK RM 014 0.5 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 17 FCU-8 CORRIDOR 100C 0.5 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 18 FCU-9 CORRIDOR 200 0.5 1 208 LVPH4 7,9 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 19 FCU-11 CORRIDOR 300 0.5 1 208 LVPH4 7,9 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 20 FCU-12 CORRIDOR 400 0.5 1 208 LVPH4 10,12 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 21 FCU-10 CORRIDOR 500 0.5 1 208 LVPH4 10,12 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 30 BCC-1 MECH AND ELEC 010 0.1 1 208 LVPH1 39,41 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 31 BCC-2 MECH AND ELEC 010 0.1 1 208 LVPH1 40,42 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 32 BCC-3 CORRIDOR 300 0.1 1 208 LVPH4 7,9 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 33 BCC-4 CORRIDOR 500 0.1 1 208 LVPH4 10,12 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 5 40 EF-2 WOMENS TLT 015 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 2 41 EF-2 MENS TLT 016 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 2 42 EF-3 TRASH/RECYCLE 011 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 43 EF-3 TRASH/RECYCLE 215 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 44 EF-3 TRASH/RECYCLE 315 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 45 EF-3 TRASH/RECYCLE 415 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 46 EF-3 TRASH/RECYCLE 515 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 47 EF-2 STAFF TLT 005 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 2 48 EF-3 CUST 217 0.02 1 120 LVPH1 33 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 49 EF-3 CUST 317 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 50 EBB-4 CONFERENCE RM 018 1.0 1 208 LVPH1 35,37 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 51 EBB-4 CONFERENCE RM 018 1.0 1 208 LVPH1 35,37 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 52 EBB-4 CONFERENCE RM 018 1.0 1 208 LVPH1 35,37 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 53 EBB-4T COMMUNITY RM 012 1.0 1 208 LVPEM 23,25 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 54 EBB-4T COMMUNITY RM 012 1.0 1 208 LVPEM 23,25 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 55 EBB-4T COMMUNITY RM 012 1.0 1 208 LVPEM 23,25 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 60 UH-1 MECH AND ELEC 010 5.0 3 208 LVPH1 52,54,56 20A/3P 3-#12, 1-#12EG IN ½"C 3-#12, 1-#12EG IN ½"C 10 AU 1 61 ECUH-1 STAIR B B01 2.0 1 208 LVPH1 47,49 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 62 ECUH-1 VESTIBULE 001 2.0 1 208 LVPH1 51,53 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 63 ECUH-1 VESTIBULE 100D 2.0 1 208 LVPH1 67,69 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 10 AU 1 70 EF-3 CUST 417 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 71 EF-3 CUST 517 0.02 1 120 LVPH4 2 20A/1P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 1 AU 1 4 80 HPU-1 ROOF 2.1 1 208 LVPH4 17,19 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 30 NF 10 AU 3R 7 81 IFCU-1 ELEVATOR SHAFT - 1 208 LVPH4 17,19 20A/2P 2-#12, 1-#12EG IN ½"C 2-#12, 1-#12EG IN ½"C 3, 11 AU 1 7 60 NF POST BID ADDENDUM #3 2019.12.31 REVISIONS No. Description Date A3 POST BID ADDENDUM #3 12.19.2019 A8 ELEVATOR SHAFT CONDITIONING 06.15.2020 A9 ECUH REV 08.10.2020 A8 A8 A9 plan ARCHITECTURAL 250 South Avenue, Suite 100Rochester, New York 14604Architectural Studio, PCplant. 585.454.4230f. 585.454.4237www.planpc.comSTUDIO Notice: It is a violation of law for any person, unless acting under the direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to afix his/her seal and the notation 'altered by' followed by his/her signature and a specific description of alterations. ©PLAN ARCHITECTURAL STUDIO, PC CONSTRUCTION PERMIT DOCUMENTSTURNER E N G I N E E R I N G , P C One Woodbury Blvd. Rochester, NY 14604 585.381.3360 Tel Project No. 001.16.01.02 PLAN PROJECT No. DATE SHARS I.D. # 20186081 e802ELECTRICAL PANEL SCHEDULESLAKEVIEW HEALTH SERVICES WESTEND HEIGHTS701 WEST COURT STREET,ITHACA, NEW YORK, 1485017167 11.30.2020 Receptacle 19360 VA 50.00% 9680 VA Other 0 VA 0.00% 0 VA Motor 5276 VA 75.00% 3957 VA TOTAL EST. DEMAND:146 A Lighting 2946 VA 90.00% 2651 VA TOTAL CONN.:217 A Heating 18289 VA 65.00% 11888 VA TOTAL EST. DEMAND:52772 VA Electric Range - 3.5 kW ... 8300 VA 80.00% 6640 VA TOTAL CONN. LOAD:78103 VA Electric Clothes Dryer 24000 VA 75.00% 18000 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:235 A 223 A 199 A TOTAL LOAD:27864 VA 26338 VA 23913 VA 71 SPARE 20 A 1 0.0 0.0 -- -- SPACE 72 69 1.0 0.0 -- -- SPACE 70 67 ECUH-1 20 A 2 1.0 0.0 -- -- SPACE 68 65 STAFF TLT HAND DRYER 20 A 1 1.0 1.0 1 20 A DISHWASHER REC 66 63 4.2 0.0 64 61 COMM KIT RANGE 50 A 2 4.2 0.6 2 30 A LCS 62 59 COMM KIT MICROWAVE 20 A 1 1.0 0.2 1 20 A STAFF KIT REC 60 57 W TLT HAND DRYER 20 A 1 1.0 58 55 M TLT HAND DRYER 20 A 1 1.0 1.7 56 53 1.0 1.7 54 51 ECUH-1 20 A 2 1.0 1.7 3 20 A EUH 52 49 1.0 0.4 50 47 ECUH-1 20 A 2 1.0 0.4 2 20 A HWRP-1 48 45 HW-2 20 A 1 0.6 0.6 1 20 A HW-3 46 43 HW-1 20 A 1 0.6 0.0 1 20 A AQUASTAT, TIME SWITCH 44 41 0.9 1.2 42 39 BCC-1, FCU-4, 6, 7, 8 20 A 2 0.9 1.2 2 20 A BCC-2, FCU-1, 2, 3, 5 40 37 1.5 2.0 38 35 CONF RM BASEBOARD 20 A 2 1.5 2.0 2 30 A DRYER 36 33 EF-2(M),EF-2(W),1-2 EF-3 20 A 1 0.1 2.0 34 31 2.0 2.0 2 30 A DRYER 32 29 DRYER 30 A 2 2.0 2.0 30 27 2.0 2.0 2 30 A DRYER 28 25 DRYER 30 A 2 2.0 1.0 1 20 A WASHER REC 26 23 2.0 1.0 1 20 A WASHER REC 24 21 DRYER 30 A 2 2.0 1.0 1 20 A WASHER REC 22 19 WASHER REC 20 A 1 1.0 1.4 1 20 A 2ND FLR CORRIDOR REC 20 17 WASHER REC 20 A 1 1.0 1.0 1 20 A STAFF MICROWAVE 18 15 WASHER REC 20 A 1 1.0 0.9 1 20 A STAFF, COMM KIT REC 16 13 COMM KITCHEN REC 20 A 1 0.7 1.1 1 20 A CONFERENCE, LAUN REC 14 11 CORR, EXT, TRASH REC 20 A 1 1.4 12 9 RECEPTION OFF REC 20 A 1 1.3 10 7 ELMSHADE COPY REC 20 A 1 1.0 0.2 8 5 ELMSHADE MED, OFF REC 20 A 1 0.7 0.2 2 20 A SITE LIGHTING 6 3 BLD MAIN OFF REC 20 A 1 0.7 1.3 1 20 A 1ST, 2ND FLR CORR LTG 4 1 EXT, MECH, OFF REC 20 A 1 0.7 1.0 1 20 A OFF,CONF,BREAK LTG 2 CKT CIRCUIT DESCRIPTION TRIP POLES A B C POLES TRIP CIRCUIT DESCRIPTION CKT NOTES:PANEL IS 2 SECTION LVPH1 MECHANICAL AND... 225 A 3Ø, 4W 120/208 WYE SURFACE 22 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS X SPD SIZE: 60 PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS X INTEGRAL SPD X TOTAL EST. DEMAND:35 A TOTAL CONN.:62 A Receptacle 14728 VA 50.00% 7364 VA TOTAL EST. DEMAND:12698 VA Motor 4960 VA 75.00% 3720 VA TOTAL CONN. LOAD:22161 VA Heating 3000 VA 65.00% 1950 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:64 A 53 A 71 A TOTAL LOAD:7549 VA 6327 VA 8316 VA 41 SPACE -- --0.0 1.0 42 39 SPACE -- -- 0.0 1.0 40 37 SPACE -- -- 0.0 1.0 3 60 A ELEVATOR 38 35 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 36 33 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 34 31 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 32 29 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 30 27 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 28 25 1.5 0.0 1 20 A SPARE 26 23 COMM RM BASEBOARD 20 A 2 1.5 1.0 1 20 A STAFF REF RECEPT 24 21 IT RM 516 REC 20 A 1 0.4 0.7 1 20 A IT RM 516 REC 22 19 IT RM 416 REC 20 A 1 0.4 0.7 1 20 A IT RM 416 REC 20 17 IT RM 316 REC 20 A 1 0.4 0.7 1 20 A IT RM 316 REC 18 15 IT RM 216 REC 20 A 1 0.4 0.7 1 20 A IT RM 216 REC 16 13 SERVER RM RECEPT 20 A 1 0.4 0.4 1 20 A SERVER RM RECEPT 14 11 5TH PANIC BUTTON REP 20 A 1 1.0 1.0 1 20 A VEST 100D DOOR OP 12 9 4TH PANIC BUTTON REP 20 A 1 1.0 1.0 1 20 A VEST 001 DOOR OP 10 7 3RD PANIC BUTTON REP 20 A 1 1.0 1.1 1 20 A COMMUNITY RM REC 8 5 2ND PANIC BUTTON REP 20 A 1 1.0 1.0 1 20 A COMM KIT REF REC 6 3 1ST PANIC BUTTON REP 20 A 1 1.0 0.2 1 20 A ELMSHADE UC REF REC 4 1 ELEV SUM PUMP 20 A 1 1.2 0.2 1 20 A HORIZON UC REF REC 2 CKT CIRCUIT DESCRIPTION TRIP POLES A (kVA)B (kVA)C (kVA)POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPEM MECHANICAL AND... ATS-E 225 A 3Ø, 4W 120/208 WYE SURFACE 22 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS SPD SIZE: PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND:13 A Receptacle 540 VA 100.00% 540 VA TOTAL CONN.:16 A Motor 1400 VA 75.00% 1050 VA TOTAL EST. DEMAND:4794 VA Lighting 3199 VA 90.00% 2879 VA TOTAL CONN. LOAD:5638 VA Heating 500 VA 65.00% 325 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:25 A 26 A 18 A TOTAL LOAD:2947 VA 2975 VA 2217 VA 29 SPACE -- --0.0 0.2 1 20 A GEN RECEPTACLE 30 27 SPACE -- -- 0.0 0.5 1 20 A GEN BATTERY CHARGER 28 25 SPACE -- -- 0.0 0.5 1 20 A GEN BLOCK HEATER 26 23 SPACE -- --0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 20 17 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 18 15 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 16 13 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 14 11 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 12 9 SMOKE DAMPERS 20 A 1 0.9 1.0 1 20 A LCP 10 7 COMMUNITY RM LTG 20 A 1 0.6 0.3 1 20 A EXTERIOR EM LTG 8 5 ELEVATOR CAB LTG 20 A 1 0.5 1.5 1 20 A 1ST FLR LIFE SAFETY LTG 6 3 ELEV SHAFT LTG, REC 20 A 1 0.4 0.2 1 20 A 2-5 FLR LIFE SAFETY LTG 4 1 FACP 20 A 1 1.5 0.0 1 20 A EXIT SIGNS 2 CKT CIRCUIT DESCRIPTION TRIP POLES A B C POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPLS MECHANICAL AND... ATS-LS 100 A 3Ø, 4W 120/208 WYE SURFACE 22 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS SPD SIZE: PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND:19 A TOTAL CONN.:20 A Receptacle 5860 VA 100.00% 5860 VA TOTAL EST. DEMAND:6823 VA Lighting 351 VA 90.00% 316 VA TOTAL CONN. LOAD:7207 VA Heating 1000 VA 65.00% 650 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:27 A 17 A 17 A TOTAL LOAD:3248 VA 1980 VA 1980 VA 29 SPACE -- --0.0 0.0 -- -- SPACE 30 27 SPACE -- -- 0.0 0.0 -- -- SPACE 28 25 SPACE -- -- 0.0 0.0 -- -- SPACE 26 23 SPACE -- --0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPARE 20 A 1 0.0 0.0 -- -- SPACE 20 17 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 18 15 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 16 13 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 14 11 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 12 9 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 10 7 HORIZON DIR, MGR REC 20 A 1 0.9 1.0 1 20 A HORIZON HD 8 5 HORIZON OFF, WAIT REC 20 A 1 1.1 0.9 1 20 A HORIZON PROG, MED REC 6 3 SUPPORT HOUSE REC 20 A 1 0.7 1.3 1 20 A HORIZON OFF REC 4 1 HORIZON OFF LTG 20 A 1 0.4 1.0 1 20 A HORIZON COPY REC 2 CKT CIRCUIT DESCRIPTION TRIP POLES A (kVA)B (kVA)C (kVA)POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPHZ SHARED COPY /... 225 A 3Ø, 4W 120/208 WYE FLUSH 22 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS SPD SIZE: PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND:73 A Receptacle 5780 VA 100.00% 5780 VA TOTAL CONN.:86 A Motor 3494 VA 75.00% 2621 VA TOTAL EST. DEMAND:15267 VA Lighting 252 VA 90.00% 227 VA TOTAL CONN. LOAD:17826 VA Electric Range - 3.5 kW ... 8300 VA 80.00% 6640 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:83 A 88 A TOTAL LOAD:8581 VA 9245 VA 23 SPACE -- -- 0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPACE -- -- 0.0 0.0 -- -- SPACE 20 17 SPACE -- -- 0.0 0.0 -- -- SPACE 18 15 SPACE -- -- 0.0 0.0 -- -- SPACE 16 13 1.4 0.0 -- -- SPACE 14 11 VRP-12K 20 A 2 1.4 1.0 1 20 A DISHWASHER 12 9 REF RECEPT 20 A 1 X 1.0 4.2 10 7 KIT REC, HOOD FAN/LTG 20 A 1 X 0.7 4.2 2 50 A RANGE RECEPT 8 5 BEDROOM RECEPT 20 A 1 X 0.9 0.5 X 1 20 A KITCHEN RECEPT 6 3 ENTRY, DINING RECEPT 20 A 1 X 0.9 1.1 X 1 20 A LIVING RM RECEPT 4 1 APARTMENT LTG 20 A 1 X 0.4 0.2 X 1 20 A BATHROOM RECEPT 2 CKT CIRCUIT DESCRIPTION TRIP POLES AFCI A (kVA)B (kVA)AFCI POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LC214 (TYPE 3)... 100 A 1Ø, 3W 120/208... FLUSH 10 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE: LOADCENTER SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND:73 A Receptacle 5780 VA 100.00% 5780 VA TOTAL CONN.:86 A Motor 3494 VA 75.00% 2621 VA TOTAL EST. DEMAND:15242 VA Lighting 224 VA 90.00% 202 VA TOTAL CONN. LOAD:17798 VA Electric Range - 3.5 kW ... 8300 VA 80.00% 6640 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:85 A 86 A TOTAL LOAD:8793 VA 9005 VA 23 SPACE -- -- 0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPACE -- -- 0.0 0.0 -- -- SPACE 20 17 SPACE -- -- 0.0 0.0 -- -- SPACE 18 15 SPACE -- -- 0.0 0.0 -- -- SPACE 16 13 DISHWASHER 20 A 1 1.0 0.0 -- -- SPACE 14 11 1.4 0.0 -- -- SPACE 12 9 VRP-12K 20 A 2 1.4 4.2 10 7 KITCHEN RECEPT 20 A 1 X 0.5 4.2 2 50 A RANGE RECEPT 8 5 KIT REC, HOOD FAN/LTG 20 A 1 X 0.7 1.0 X 1 20 A REF RECEPT 6 3 ENTRY, BEDRM RECEPT 20 A 1 X 1.4 1.4 X 1 20 A MECH, LIV, BEDRM REC 4 1 APARTMENT LTG 20 A 1 X 0.3 0.2 X 1 20 A BATHROOM RECEPT 2 CKT CIRCUIT DESCRIPTION TRIP POLES AFCI A (kVA)B (kVA)AFCI POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LC213 (TYPE 4)... 100 A 1Ø, 3W 120/208... FLUSH 10 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE: LOADCENTER SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND:71 A Receptacle 5240 VA 100.00% 5240 VA TOTAL CONN.:83 A Motor 3494 VA 75.00% 2621 VA TOTAL EST. DEMAND:14702 VA Lighting 224 VA 90.00% 202 VA TOTAL CONN. LOAD:17258 VA Electric Range - 3.5 kW ... 8300 VA 80.00% 6640 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:71 A 92 A TOTAL LOAD:7333 VA 9925 VA 23 SPACE -- -- 0.0 0.0 -- -- SPACE 24 21 SPACE -- -- 0.0 0.0 -- -- SPACE 22 19 SPACE -- -- 0.0 0.0 -- -- SPACE 20 17 SPACE -- -- 0.0 0.0 -- -- SPACE 18 15 SPACE -- -- 0.0 0.0 -- -- SPACE 16 13 SPACE -- -- 0.0 0.0 -- -- SPACE 14 11 1.4 1.0 1 20 A DISHWASHER REC 12 9 VRP-12K 20 A 2 1.4 4.2 10 7 REF RECEPT 20 A 1 X 1.0 4.2 2 50 A RANGE RECEPT 8 5 KITCHEN RECEPT 20 A 1 X 0.5 0.7 X 1 20 A KIT REC, HOOD FAN/LTG 6 3 ENTRY, LIVING RECEPT 20 A 1 X 1.3 1.1 X 1 20 A BEDROOM RECEPT 4 1 APARTMENT LTG 20 A 1 X 0.3 0.2 X 1 20 A BATHROOM RECEPT 2 CKT CIRCUIT DESCRIPTION TRIP POLES AFCI A (kVA)B (kVA)AFCI POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LC202 (TYPE 2)... 100 A 1Ø, 3W 120/208... FLUSH 10 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE: LOADCENTER SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD TOTAL EST. DEMAND:118 A TOTAL CONN.:151 A Receptacle 5760 VA 100.00% 5760 VA TOTAL EST. DEMAND:42468 VA Motor 47511 VA 75.00% 35633 VA TOTAL CONN. LOAD:54465 VA Lighting 1194 VA 90.00% 1075 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:151 A 151 A 152 A TOTAL LOAD:18073 VA 18103 VA 18289 VA 29 SPACE -- --0.0 0.0 -- -- SPACE 30 27 SPACE -- -- 0.0 0.0 -- -- SPACE 28 25 SPACE -- -- 0.0 0.0 -- -- SPACE 26 23 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 24 21 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 22 19 1.1 0.0 1 20 A SPARE 20 17 HPU-1, IFCU-1 20 A 2 1.1 6.6 18 15 7.7 6.6 16 13 7.7 6.6 3 70 A DOAS-1 14 11 ODU-1 80 A 3 7.7 0.6 12 9 0.6 0.6 2 20 A BCC-4, FCU-10, FCU-12 10 7 BCC-3, FCU-9, FCU-11 20 A 2 0.6 0.5 1 20 A RADON FANS 8 5 5TH FLR CORR RECEPT 20 A 1 1.6 0.7 1 20 A RADON FANS 6 3 4TH FLR CORR RECEPT 20 A 1 1.4 1.2 1 20 A 3RD, 4TH, 5TH CORR LTG 4 1 3RD FLR CORR RECEPT 20 A 1 1.4 0.1 1 20 A 3RD-5TH FLR EF-3'S 2 CKT CIRCUIT DESCRIPTION TRIP POLES A B C POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPH4 I.T. CLOSET 216 225 A 3Ø, 4W 120/208 WYE SURFACE 10 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM X 200% NEUTRAL SUB-FEED LUGS SPD SIZE: PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD METER CENTERMECH AND ELEC 010 METER CENTER METER CENTERMETER CENTER METER CENTER SHUNT TRIP MECH AND ELEC 010 MECH AND ELEC 010 SHARED COPY/FILES 4TH FLR IT ROOM METER CENTER REVISIONS No. Description Date A1 A-1 Addendum 10.23.2019 A7 SITEWORK & STORAGE SHED 05.15.2020 A8 ELEVATOR SHAFT CONDITIONING 06.15.2020 A9 ECUH REV 08.10.2020 A15 ASI-15 APT DW 12.07.20 A17 ELMSHADE METER 04.19.2021 METER CENTER A17 TOTAL EST. DEMAND:21 A TOTAL CONN.:22 A Receptacle 3420 VA 100.00% 3420 VA TOTAL EST. DEMAND:4292 VA Lighting 249 VA 90.00% 224 VA TOTAL CONN. LOAD:4666 VA Heating 1000 VA 65.00% 650 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS TOTAL AMPS:26 A 17 A TOTAL LOAD:2866 VA 1800 VA 11 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 12 9 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 10 7 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 8 5 ELMSHADE MED, OFF REC 20 A 1 0.9 1.0 1 20 A ELMSHADE MED HD 6 3 ELMSHADE OFF REC 20 A 1 0.9 0.9 1 20 A ELMSHADE OFF REC 4 1 ELMSHADE LTG 20 A 1 0.2 0.7 1 20 A PROG, BLDG MAIN REC 2 CKT CIRCUIT DESCRIPTION TRIP POLES A (kVA)B (kVA)POLES TRIP CIRCUIT DESCRIPTION CKT NOTES: LVPELM ELMSHADE MED.... 100 A 1Ø, 3W 120/208... FLUSH 10 QO TYPE 1 MCB MLONAMELOCATIONSOURCERATING (AMPS)PHASE/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE HINGED TRIM 200% NEUTRAL SUB-FEED LUGS SPD SIZE: PANELBOARD SCHEDULE SE RATED SUB-FEED BREAKER FEED-THRU LUGS INTEGRAL SPD