Loading...
HomeMy WebLinkAbout!20210205 - Cayuga Park MOB Volume 2 CD SetHOLT Architects, P.C. Architects, Planners, and Interior Designers 619 West State Street, Ithaca, New York 14850 132 E. Jefferson Street, Syracuse, New York 13202 Tel 607.273.7600 www.holt.com PROJECT INFORMATION DATE: JOB NUMBER: CONSTRUCTION CLASSIFICATION: SPRINKLER PROTECTION: BUILDING USE CLASSIFICATION: TOTAL AREA OF PROJECT (SF): Jensen / BRV Engineering Structural Engineering 1653 Main Street, Rochester, New York 14609 Tel 585.482.8130 www.jensenbrv.com EC4B Engineering Mechanical, Electrical, Plumbing & Fire Protection Engineering 15 Schoen Place, Suite 300, Pittsford, New York 14534 Tel 607.734.8492 www.ec4b.com Park Grove - Cayuga Medical Center MEDICAL OFFICE BUILDING Cayuga Park, Ithaca, New York 14850 MEDICAL OFFICE BUILDINGPark Grove - Cayuga Medical Center 02/05/2021 2018089 BCNYS IIA, (NFPA II FULLY SPRINKLERED BUSINESS 61,050 G002 PROJECT LOCATION PLANS (111) EQUIVALENT) VOLUME 2 -FIRE PROTECTION, PLUMBING, MECHANICAL & ELECTRICAL Received by DiMarco 2/15/2021 DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/10/2021 10:50:43 AMG010 SHEET LIST 02/05/2021 2018089 BPL Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGVOLUME 1 A700 FINISH SCHEDULE A711 FIRST FLOOR FINISH PLAN - SECTOR 1 A712 FIRST FLOOR FINISH PLAN - SECTOR 2 A713 FIRST FLOOR FINISH PLAN - SECTOR 3 A721 SECOND FLOOR FINISH PLAN - SECTOR 1 A722 SECOND FLOOR FINISH PLAN - SECTOR 2 A723 SECOND FLOOR FINISH PLAN - SECTOR 3 A731 THIRD FLOOR FINISH PLAN - SECTOR 1 A732 THIRD FLOOR FINISH PLAN - SECTOR 2 A741 FOURTH FLOOR FINISH PLAN - SECTOR 1 A742 FOURTH FLOOR FINISH PLAN - SECTOR 2 A751 FIFTH FLOOR FINISH PLAN - SECTOR 1 A752 FIFTH FLOOR FINISH PLAN - SECTOR 2 A901 FIRST FLOOR FURNITURE AND EQUIPMENT PLAN A902 SECOND FLOOR FURNITURE & EQUIPMENT PLAN A903 THIRD FLOOR FURNITURE & EQUIPMENT PLAN A904 FOURTH FLOOR FURNITURE & EQUIPMENT A905 FIFTH FLOOR FURNITURE & EQUIPMENT PLAN VOLUME 1 GENERAL G001 COVER SHEET G010 SHEET LIST G101 CODE REVIEW AND CHARTS G102 CODE REVIEW AND CHARTS G110 SITE CODE CONFORMANCE PLAN (PRINT IN COLOR) G131 FIRST FLOOR CODE CONFORMANCE PLAN (PRINT IN COLOR) G132 SECOND FLOOR CODE CONFORMANCE PLAN (PRINT IN COLOR) G133 THIRD FLOOR CODE CONFORMANCE PLAN (PRINT IN COLOR) G134 FOURTH FLOOR CODE CONFORMANCE PLAN (PRINT IN COLOR) G135 FIFTH FLOOR CODE CONFORMANCE PLAN (PRINT IN COLOR) G136 ROOF CODE CONFORMANCE PLAN (PRINT IN COLOR) G137 CODE CONFORMANCE BUILDING SECTION(PRINT IN COLOR) G201 FIRE PROOFING G301 STACK DIAGRAM (DOH) (PRINT IN COLOR) STRUCTURAL S001 GENERAL NOTES S002 GERNERAL NOTES AND SPECIAL INSPECTION S003 FOUNDATION LOADING PLAN AND C&C WIND LOADING S100 FOUNDATION PLAN S101 COLUMN AND SLAB PLAN S102 SECOND FLOOR FRAMING PLAN S103 THIRD FLOOR FRAMING PLAN S104 FOURTH FLOOR FRAMING PLAN S105 FIFTH FLOOR FRAMING PLAN S106 ROOF FRAMING PLAN S500 DETAILS AND SECTIONS S501 DETAILS AND SECTIONS S502 DETAILS AND SECTIONS S503 DETAILS AND SECTIONS S504 DETAILS AND SECTIONS S505 COLUMN SCHEDULE & BRACED FRAME ELEVATION S506 DETAILS AND SECTIONS ARCHITECTURAL A001 GENERAL NOTES, EXTERIOR WALL & ROOF SYSTEMS A002 INTERIOR WALL & FIREPROOFING SYSTEMS A111 FIRST FLOOR PLAN - SECTOR 1 A112 FIRST FLOOR PLAN - SECTOR 2 A113 FIRST FLOOR PLAN - SECTOR 3 A121 SECOND FLOOR PLAN - SECTOR 1 A122 SECOND FLOOR PLAN - SECTOR 2 A123 SECOND FLOOR PLAN - SECTOR 3 A131 THIRD FLOOR PLAN - SECTOR 1 A132 THIRD FLOOR PLAN - SECTOR 2 A141 FOURTH FLOOR PLAN - SECTOR 1 A142 FOURTH FLOOR PLAN - SECTOR 2 A151 FIFTH FLOOR PLAN - SECTOR 1 A152 FIFTH FLOOR PLAN - SECTOR 2 A160 ROOF PLAN A211 FIRST FLOOR REFLECTED CEILING PLAN - SECTOR 1 A212 FIRST FLOOR REFLECTED CEILING PLAN - SECTOR 2 A213 FIRST FLOOR REFLECTED CEILING PLAN - SECTOR 3 A221 SECOND FLOOR REFLECTED CEILING PLAN - SECTOR 1 A222 SECOND FLOOR REFLECTED CEILING PLAN - SECTOR 2 A223 SECOND FLOOR REFLECTED CEILING PLAN - SECTOR 3 A231 THIRD FLOOR REFLECTED CEILING PLAN - SECTOR 1 A232 THIRD FLOOR REFLECTED CEILING PLAN - SECTOR 2 A241 FOURTH FLOOR REFLECTED CEILING PLAN - SECTOR 1 A242 FOURTH FLOOR REFLECTED CEILING PLAN - SECTOR 2 A251 FIFTH FLOOR REFLECTED CEILING PLAN - SECTOR 1 A252 FIFTH FLOOR REFLECTED CEILING PLAN - SECTOR 2 A300 EXTERIOR FINISH SCHEDULE AND GENERAL PRODUCT INFO A301 EXTERIOR ELEVATIONS A302 EXTERIOR ELEVATIONS A303 EXTERIOR ELEVATIONS A350 TYPICAL MOUNTING HEIGHTS AND ELEVATIONS A351 INTERIOR ELEVATIONS A352 INTERIOR ELEVATIONS A353 INTERIOR ELEVATIONS A354 INTERIOR ELEVATIONS A355 INTERIOR ELEVATIONS A356 INTERIOR ELEVATIONS A357 INTERIOR ELEVATIONS A358 INTERIOR ELEVATIONS A359 INTERIOR ELEVATIONS A360 INTERIOR ELEVATIONS A401 BUILDING SECTIONS A451 WALL SECTIONS A452 WALL SECTIONS A453 WALL SECTIONS A454 WALL SECTIONS A455 WALL SECTIONS A461 ELEVATOR PLANS, SECTIONS & DETAILS A462 STAIR #1 PLANS A463 STAIR #1 SECTIONS A465 STAIR #2 PLANS A466 STAIR #2 SECTIONS A467 STAIR #3 PLANS & SECTION A468 GUARDRAIL & HANDRAIL DETAILS A469 STAIR DETAILS & ELEVATIONS A501 EXTERIOR DETAILS A502 EXTERIOR DETAILS A503 EXTERIOR DETAILS A550 INTERIOR DETAILS - FLOOR TRANSITIONS A551 INTERIOR DETAILS - FINISHES A552 INTERIOR DETAILS - CASEWORK A561 RCP DETAILS A562 ENLARGED PLANS, ELEVATIONS AND SECTIONS A563 ENLARGED PLANS, ELEVATIONS AND SECTIONS A564 ENLARGED PLANS, ELEVATIONS AND SECTIONS A565 ENLARGED PLANS, ELEVATIONS AND SECTIONS A601 DOOR AND FRAME SCHEDULES AND LEGENDS A602 DOOR AND FRAME SCHEDULES A603 DOOR AND FRAME TYPES A604 BORROWED LITES A605 INTERIOR STOREFRONT ELEVATIONS & DETAILS A652 EXTERIOR WINDOW AND SIGNAGE ELEVATIONS A653 VERTICAL SUNSHADES REVISION SCHEDULE NAME DATE VOLUME 2 FIRE PROTECTION FP001 LEGEND & GENERAL NOTES FP101 FIRST FLOOR PLAN FP102 SECOND FLOOR PLAN FP103 THIRD FLOOR PLAN FP104 FOURTH FLOOR PLAN FP105 FIFTH FLOOR PLAN FP301 RISER DIAGRAM FP501 DETAILS PLUMBING P001 LEGEND & GENERAL NOTES P100 FOUNDATION PLAN P101 FIRST FLOOR PLAN - SANITARY/ WASTE AND STORM P102 SECOND FLOOR PLAN - SANITARY/ WASTE AND STORM P103 THIRD FLOOR PLAN - SANITARY/ WASTE AND STORM P104 FOURTH FLOOR PLAN - SANITARY/ WASTE AND STORM P105 FIFTH FLOOR PLAN - SANITARY/ WASTE AND STORM P106 ROOF PLAN P201 FIRST FLOOR PLAN - DOMESTIC P202 SECOND FLOOR PLANS - DOMESTIC P203 THIRD FLOOR PLANS - DOMESTIC P204 FOURTH FLOOR PLANS - DOMESTIC P205 FIFTH FLOOR PLAN - DOMESTIC P301 FIRST FLOOR PLAN - INDIRECT WASTE P302 SECOND FLOOR PLAN - INDIRECT WASTE P303 THIRD FLOOR PLAN - INDIRECT WASTE P304 FOURTH FLOOR PLAN - INDIRECT WASTE P305 FIFTH FLOOR PLAN - INDIRECT WASTE P401 SCHEDULES P402 SCHEDULES P501 DETAILS MECHANICAL M001 LEGEND & ABBREVIATIONS M101 FIRST FLOOR PLAN M102 SECOND FLOOR PLAN M103 THIRD FLOOR PLAN M104 FOURTH FLOOR PLAN M105 FIFTH FLOOR PLAN M106 ROOF PLAN M201 FIRST FLOOR PIPING PLAN M202 SECOND FLOOR PIPING PLAN M203 THIRD FLOOR PIPING PLAN M204 FOURTH FLOOR PIPING PLAN M205 FIFTH FLOOR PIPING PLAN M301 VRF SCHEMATIC M302 VRF SCHEMATIC M303 VRF SCHEMATIC M304 VRF SCHEMATIC M305 VRF SCHEMATIC M401 SCHEDULES M402 OUTSIDE AIR MATRIX M403 OUTSIDE AIR MATRIX M404 OUTSIDE AIR MATRIX M405 OUTSIDE AIR MATRIX M406 OUTSIDE AIR MATRIX M501 DETAILS M502 VRF DETAILS ELECTRICAL E001 LEGEND & ABBREVIATIONS E100 SITE PLAN E101 FIRST FLOOR POWER & SYSTEMS PLAN E102 SECOND FLOOR POSER & SYSTEMS PLAN E103 THIRD FLOOR POWER & SYSTEMS PLAN E104 FOURTH FLOOR POWER & SYSTEMS PLAN E105 FIFTH FLOOR POWER & SYSTEMS PLAN E106 ROOF PLAN E201 FIRST FLOOR LIGHTING PLAN E202 SECOND FLOOR LIGHTING PLAN E203 THIRD FLOOR LIGHTING PLAN E204 FOURTH FLOOR LIGHTING PLAN E205 FIFTH FLOOR LIGHTING PLAN E301 ONE-LINE DIAGRAM E401 SCHEDULES E402 SCHEDULES E403 SCHEDULES E404 SCHEDULES E405 SCHEDULES E406 SCHEDULES E407 SCHEDULES E408 SCHEDULES E501 DETAILS E502 DETAILS E503 DETAILS E504 DETAILS E505 DETAILS E506 DETAILS E507 DETAILS E508 DETAILS E509 DETAILS E510 DETAILS E511 DETAILS E601 ENLARGED RADIOLOGY PLAN E602 ENLARGED RADIOLOGY PLAN E603 ENLARGED RADIOLOGY PLAN (PRINT IN COLOR) (PRINT IN COLOR) (PRINT IN COLOR) A651 CURTAINWALL AND STOREFRONT ELEVATIONS (PRINT IN COLOR) A652 EXTERIOR WINDOW AND SIGNAGE ELEVATIONS (PRINT IN COLOR) A653 VERTICAL SUNSHADES (PRINT IN COLOR) Received by DiMarco 2/15/2021 GENERAL NOTES:1. THE FIRE PROTECTION SYSTEM DESIGN, INSTALLATION AND MATERIALSSHALL CONFORM TO THE FIRE CODE AND AUTHORITIES HAVINGJURISDICTION. IN CASE OF CONFLICTS WITH CODES, DRAWINGS, ORSPECIFICATIONS, THE MOST STRINGENT SHALL PREVAIL.2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFYTHE EXACT LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALLUTILITIES AND PIPING, AND SHALL IMMEDIATELY NOTIFY THE ARCHITECTOF ANY DISCREPANCIES.3. THE DRAWINGS WERE PREPARED WITH THE BEST STRUCTURAL ANDARCHITECTURAL INFORMATION AVAILABLE. IT IS UNDERSTOOD THATEQUIPMENT LOCATIONS AND ROUTING OF PIPING MAY VARY FROM THATSHOWN ON THE PLANS AS CONSTRUCTION PROCEEDS.4. THESE DRAWINGS DO NOT INCLUDE ALL NECESSARY SAFETYREQUIREMENTS. CONTRACTOR TO COMPLY TO THE SAFETYREQUIREMENTS SET FORTH BY THE LOCAL AUTHORITIES HAVINGJURISDICTION.5. THESE DRAWINGS ARE FOR BIDDING PURPOSES ONLY. THEY AREESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT MANY OFFSETS,BENDS, UNIONS, SPECIFIC FITTINGS AND EXACT LOCATIONS ARE NOTINDICATED.6. ALL FIRE PROTECTION WORK SHALL BE INSTALLED SO AS TO AVOIDINTERFERENCE WITH ELECTRICAL EQUIPMENT, MECHANICALEQUIPMENTAND STRUCTURAL FRAMING, SKYLIGHTS, ETC.7. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILINGACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLANAND ELECTRICAL LIGHTING PLAN.8. COORDINATE ALL LOCATIONS, SIZES AND ELEVATIONS OF ALL SLEEVESTHROUGH WALLS, BEAMS, SLABS AND FOOTING WITH STRUCTURAL ANDARCHITECTURAL DRAWINGS. ALL PIPES SLEEVING THROUGH BEAMS ORFOOTINGS SHALL HAVE A SLEEVE DIAMETER OF TWO PIPE SIZES OVERTHE PIPE PASSING THROUGH THE FOOTING OR PER STRUCTURALDRAWING. THE MOST STRINGENT SHALL PREVAIL.9. PIPING SUPPORTS. ALL PIPING TO BE SUPPORTED WITH HANGERS ANDBRACKETS WHICH PROVIDE ISOLATION FROM FRAMING. CONTACTBETWEEN PIPE AND SUPPORT TO BE LINED WITH PLASTIC OR FELT.10.ALL FLOOR AND WALL PENETRATIONS MUST BE SEALED WATERTIGHTAND VERMIN PROOF.11.FIRE PROTECTION CONTRACTOR SHALL COORDINATE COMPLETE FIREPROTECTION INSTALLATION AND REQUIREMENTS PRIOR TO SUBMITTINGBID WITH ALL LOCAL DISTRICTS AND GOVERNING AUTHORITIES. INCLUDEALL FINDINGS WITHIN THE BASE BID.12.PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE ANDFEDERAL CODES. OBTAIN ALL REQUIRED PERMITS. COORDINATE ALLWORK WITH LOCAL FIRE MARSHAL.13. PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, SLABS ANDDECKS AS REQUIRED FOR WORK SHOWN. COORDINATE ALL WORK WITHOWNER AND GENERAL CONTRACTOR.14. REFER TO ARCHITECTURAL DRAWINGS AND THE PROJECTSPECIFICATIONS FOR PROJECT PHASING REQUIREMENTS.15.PROVIDE FULL SPRINKLER COVERAGE FOR ALL SPACES WITHIN THEPROJECT AREA IN COMPLIANCE WITH LOCAL, STATE AND FEDERALCODES, NFPA-13 AND OWNER'S INSURANCE CARRIER/UNDERWRITER.16.PROVIDE FULL SPRINKLER COVERAGE FOR ALL SPACES WITHIN THEPROJECT AREA IN COMPLIANCE WITH LOCAL, STATE AND FEDERALCODES, NFPA-13 AND OWNER'S INSURANCE CARRIER/UNDERWRITER.17. PROVIDE SPRINKLER SHOP DRAWINGS AND HYDRAULIC CALCULATIONSWITH ALL INFORMATION NOTED BY NFPA-13. DO NOT START ANY WORKUNTIL DRAWINGS AND CALCULATIONS HAVE BEEN APPROVED BY THEPROJECT ENGINEER, OWNER'S AGENTS AND LOCAL FIRE MARSHAL.18.OBTAIN WATER FLOW TEST DATA (PRESSURES AND FLOWS) ASREQUIRED. PROVIDE ALL FLOW TESTS REQUIRED IF CURRENT TESTDATA IS UNAVAILABLE.19.COORDINATE SPRINKLER SYSTEM WITH ALL OTHER TRADES, BUILDINGCONDITIONS, ETC. OFFSET SPRINKLER SYSTEM PIPING AS REQUIRED(PROVIDE ALL FITTINGS, CONNECTIONS, ETC.)20.FOR ALL AREAS WITH LAY-IN CEILINGS, PROVIDE SPRINKLERS IN THECENTER OF CEILING TILES (2x2 PATTERN). REFER TO ARCHITECTURALPLAN FOR CEILING GRID LAYOUT.21. THE SPRINKLER/FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLYCALCULATE ALL SPRINKLER SYSTEMS SHOWN ON THE DRAWING ANDSHALL SIZE PIPING ACCORDINGLY.22.SUBMITTALS AND SHOP DRAWINGS: AS SOON AS POSSIBLE AND WITHIN21 DAYS AFTER AWARD OF THE CONTRACT, AND BEFORE THEIRPURCHASE, THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT 6BOUND BOOKLETS FOR APPROVAL AND CONTAINING A COMPLETE LISTOF MATERIALS, SPECIALTIES AND EQUIPMENT HE IS TO FURNISH FORTHE INSTALLATION. ALL SUBMITTALS SHALL BE MADE AT ONE TIME. NODEVIATION OF PLUMBING FIXTURES WILL BE ACCEPTED. BASED ONAPPROVAL OF ALTERNATE PRIOR TO BID.23. COORDINATE FIRE PROTECTION SYSTEMS WITH WORK OF ALL OTHERTRADES PRIOR TO ANY FABRICATION OR INSTALLATION.24.ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THEEQUIPMENT MANUFACTURER'S RECOMMENDATIONS AND APPLICABLECODES, PROVIDE ALL FITTINGS, VALVES, AND OTHER DEVICES REQUIREDFOR A COMPLETE WORKABLE INSTALLATION.25. MAINTENANCE LABEL SHALL BE AFFIXED TO ALL FIRE PROTECTIONEQUIPMENT AND A MAINTENANCE MANUAL SHALL BE PROVIDED TOOWNER'S REPRESENTATIVE.26.FIRE PROTECTION CONTRACTOR SHALL LAYOUT SPRINKLER SYSTEM.COORDINATE WITH ALL OTHER TRADES, AND SHALL PROVIDE SPRINKLERSHOP DRAWINGS AND HYDRAULIC CALCULATIONS. SPRINKLER PIPINGSHALL BE SIZED HYDRAULICALLY.27. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS OVER 4FEET WIDE SUCH AS DUCTS, OPEN GRATE FLOORING AND OVERHEADDOORS.28. COORDINATE WITH ELECTRICAL TRADE PRIOR TO ORDERINGELECTRICALLY OPERATED EQUIPMENT FOR AVAILABLE VOLTAGES ATEQUIPMENT LOCATIONS.29.PIPE SIZE DISCREPANCIES BETWEEN FLOOR PLANS AND RISERDIAGRAMS LARGER PIPE SIZE INDICATED WILL TAKE PRECEDENCE.30.THESE PLANS INDICATE APPROXIMATE ROUGH-INS ONLY FOREQUIPMENT NOT IN THIS SECTION (N.I.T.S.) EXACT ROUGH-INDIMENSIONS MUST BE OBTAINED FROM THE EQUIPMENTMANUFACTURER.31. THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE ALLREQUIREMENTS FOR ALL POINTS OF CONNECTION WITH THE GENERALCONTRACTOR AND OTHER TRADES PRIOR TO BID.32.FIRE PROTECTION CONTRACTOR SHALL LAYOUT SPRINKLER SYSTEM,COORDINATE WITH ALL OTHER TRADES, AND SHALL PROVIDE SPRINKLERSHOP DRAWINGS AND HYDRAULIC CALCULATIONS. SPRINKLER PIPINGSHALL BE SIZED HYDRAULICALLY.33.CONTRACTOR SHALL PROVIDE ALL VALVES AND BACKFLOW PREVENTIONDEVICES AS REQUIRED BY STATE AND LOCAL CODES.34.SPRINKLER HEADS WITHIN ATTIC SPACE SHALL BE 212 F.35. PROVIDE CORROSIVE COATING ON SPRINKLER HEADS IN POOL.APPLICABLE CODES:THE INTERNATIONAL FIRE CODE.NFPA 13: STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.NFPA 14: STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS.NFPA 25: RECOMMENDED PRACTICE FOR THE INSPECTION, TESTING ANDMAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS.SPRINKLER SYSTEM DESCRIPTION:THE FIRE PROTECTION SYSTEM SHALL BE A WETPIPE AUTOMATICSPRINKLER SYSTEM ARRANGED TO PROPERLY PROTECT ALL SPACESAS INDICATED.STANDPIPE SYSTEM DESCRIPTION:THE STANDPIPE SYSTEM SHALL BE A WET MANUAL CLASS I STANDPIPESYSTEM.FLOW TEST DATA:STATIC PRESSURE94PSIRESIDUAL PRESSURE62PSIFLOW1900GPMCLASSIFICATION OF OCCUPANCIES:1.LIGHT HAZARD:WATER DENSITY:0.10 GPM/SQ. FT.HYDRAULIC REMOTE AREA:1500 SQ. FT.COMBINED HOSE DEMAND:100 GPMWATER DENSITY:0.15 GPM/SQ. FT.HYDRAULIC REMOTE AREA:1500 SQ. FT.COMBINED HOSE DEMAND:250 GPM2. ORDINARY GROUP I:SYSTEM PROTECTION AREA LIMITATIONS:LIGHT HAZARD:52,000 SQ. FT.ORDINARY HAZARD: 52,000 SQ. FT.TSSYMBOLDESCRIPTIONSHUT OFF VALVE WITH TAMPER SWITCH (TS)FLOW SWITCH (FS)FIRE PROTECTION SYMBOLS LISTREMOVE TO THIS POINTNEW TO EXISTING CONNECTIONEXISTING PIPINGPIPING TO BE REMOVEDDROP CONNECTIONELBOW UPDIRECTION OF FLOWCAP OR PLUGCHECK VALVEPRESSURE GAGEBACKFLOW PREVENTERDRY PIPE VALVEALARM CHECK VALVESIDEWALL SPRINKLER HEADPENDENT SPRINKLER HEADSEMI-RECESSED SPRINKLER HEADUPRIGHT SPRINKLER HEADCONCEALED SPRINKLER HEADFIRE DEPARTMENT CONNECTION (FDC)PIPE CONTINUATION (SINGLE LINE)PIPE CONTINUATION (DOUBLE LINE)BREAKBUTTERFLY VALVEPUMPFIRE HYDRANTELBOW DOWNFSNOTE: NOT ALL SYMBOLS ARE NECESSARILY USED ON THIS PROJECTNEW PIPINGEXHIBIT "B" - PIPING MATERIALS (FIRE PROTECTION)(NOTES AT END OF EXHIBIT "B")SERVICEPIPE MATERIALFITTINGSCONNECTIONSSPRINKLER(WET)SCHEDULE 40, BLACK STEEL2" AND SMALLERMALLEABLEORDUCTILE IRONTHREADEDSCHEDULE 10, BLACK STEEL 2 1/2" AND LARGERMALLEABLEORDUCTILE IRONROLL GROOVED MECHANICAL TYPE COUPLINGSFIRE STANDPIPESCHEDULE 40, BLACK STEEL2-1/2" AND SMALLERMALLEABLE IRONTHREADEDSCHEDULE 10, BLACK STEEL3" AND LARGERMALLEABLEORDUCTILE IRONROLL GROOVED MECHANICAL TYPE RIGID COUPLINGSFIRE SERVICEDUCTILE IRONW/CEMENT LININGBELL & SPIGOTMECHANICAL OR GROOVED RUBBER GASKETUSE GALVANIZED STEEL PIPE AND FITTINGS FOR ALL ABOVEGROUND EXTERIOR LOCATIONS PASSING THROUGH EXTERIOR WALLS AND WHERE CALLED FOR.NOTES FOR EXHIBIT BNOTE 1:ALL EXPOSED PIPING WITHIN FINISHED AREAS SHALL BE PAINTED WITH A PRIMER COAT AND TWO FINISH COATS. COLOR PER THE ARCHITECT/OWNER.NOTE 2:803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:41 PMFP001LEGEND &GENERALNOTES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.12345ABCE3.8F3.9WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEVS109EXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1STAIR2ST2-1CORRIDOR122VITALSALCOVE105ACIRCULATION105SUB-WAITING105BCIRCULATION105CIRCULATION10588544569107CORRIDOR135WAITING/CIRCULATION123BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128LABORATORY126SPECIMENTOILET127STAFFTOILET131CORRIDOR143BUILDINGMAINTENANCETOILET/SHOWER138ATREATMENT117CORRIDOR143RADIOLOGY(X-RAY)119STATLAB/MED110EXAM113MAINLOBBY100EVS125CLEANHOLDING107HOLDING/MAIL100CSTAFFBREAK102SHAREDPROVIDEROFFICE104111312FPFPFP123FPFP888MECHANICAL145WAITING/CIRCULATION123WAITING/CIRCULATION123CIRCULATION105RECEPTION101BVISITORTOILET101ALOBBY/WAITING101MAINLOBBY100803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:00:44 PMFP101FIRST FLOORPLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNDRAWING NOTES:12PROVIDE UPRIGHT SPRINKLER HEAD UNDER LOWEST LANDING OF STAIRWELL.PROVIDE HEAD AT BOTTOM OF ELEVATOR SHAFT PER NFPA.34SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).5SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).678FIRE SERVICE. REFER TO DETAIL DRAWING(S).FIRE DEPARTMENT CONNECTION (FDC). REFER TO DETAIL DRAWING(S). SLEEVE AND SEAL THROUGH WALL.9PROVIDE DRY SPRINLKER HEAD.TERMINATE 8" INDIRECT WASTE AT BLDG'S EXTERIOR 12" ABOVE FINISHED GRADE WITH TURNED DOWN ELBOW, 12x12 SPLASH BLOCK, BUG SCREEN AND FLAPPER VALVE. SLEEVE AND SEAL THROUGH WALL.GENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. 3WATER SERVICE ROOM 3D VIEW10SLEEVE AND SEAL.11OPEN TO ABOVE.12WET FIRE PROTECTION LINE TO FEED FIRST FLOOR SPRINKLERS.13TO FIRE DEPARTMENT CONNECTION (FDC).3/16" = 1'-0"1FIRST FLOOR PLANREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223STAIR2ST2-1CORRIDOR23212STAFFBREAK242MULTIPURPOSE/ACTIVITY235TELMED233EDUCATION/CONFERENCE234RESPITE/LACTATION239STAFFTOILET236STAFFBREAK242RESPITE/LACTATION240STAFFTOILET237RESPITE/MEDITATION241OFFICE238UnoccupiedUnoccupiedIT/ELEC243MAINLOBBY100WAITING201SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203MULTIPURPOSE/CONSULT/TELEMED204SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDSTAFFBREAK208MANAGEROFFICE209PHYSICIANOFFICE/DICTATION213NURSE214CIRCULATION2283CIRCULATION207LAB221TRIAGENURSEALCOVE207AWALKINGTRACK200DENTALOFFICE230WALKINGTRACK200STAIR1ST1-2803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:01:05 PMFP102SECONDFLOOR PLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. 4PROVIDE DRY SPRINKLER HEAD.DRAWING NOTES:123SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).3/16" = 1'-0"1SECOND FLOOR PLANREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8ELEC/DATA323123PROVIDEROFFICE339ANURSEWORK339EXAM/CONSULT328EXAM/CONSULT329CIRCULATION304EVS330TRIAGENURSE339BEXAM/CONSULT327EXAM/CONSULT328EXAM/CONSULT331PATIENTTOILET336SPECIALTYEXAM/TREATMENT/TELEMED335CIRCULATION304PATIENTTOILET335ALAB334LABDRAW332SPECIMENCOLLECTION333STAIR1ST1-3GUESTWAITING/CIRCULATION300PUBLICTOILET300APUBLICTOILET300BREGISTRATION301REGISTRATION301OFFICEMANAGER301APATIENTTOILET302PATIENTVITALSALCOVE310CENTRALSOILEDWORK311EXAM/CONSULT309EXAM/CONSULT308EXAM/CONSULT307STAFFTOILET305ASTAFFBREAKAREA305SPECIALTYEXAM/TREATMENT303EXAM/CONSULT306PROVIDEROFFICE317ANURSEWORKAREA317BCENTRALCLEANWORK312EXAM/CONSULT313EXAM/CONSULT314EXAM/CONSULT315EXAM/CONSULT316EXAM/CONSULT322EXAM/CONSULT321EXAM/CONSULT320EXAM/CONSULT319EXAM/CONSULT318NURSEWORKAREA317EPROVIDEROFFICE317FTRIAGENURSE324SPECIALTYEXAM/TREATMENT326PATIENTTOILET327PATIENTTOILET326ASTAFFTOILET325??CIRCULATION304STAFFCIRCULATION317CIRCULATION304GUESTWAITING/CIRCULATION300STAIR2ST2-14444444803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:01:24 PMFP103THIRD FLOORPLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. DRAWING NOTES:123SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).3/16" = 1'-0"1THIRD FLOOR PLAN4DRY SPRINKLER HEAD.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445EVS439STAIR2ST2-1STAIR1ST1-312PROCEDUREROOM442PROCEDUREROOM441PROCEDUREROOM440RECEPTION436PROVIDEROFFICE436AWAITING434CIRCULATION435STAFFBREAK443CLEANWORKROOM&EQUIP.STORAGE437SOILEDWORKROOM438ELEVATORLOBBY&PUBLICCORRIDOR400WHEELCHAIRSTORAGE400CIMAGINGGUESTLOUNGE/WAITING401DEXASCAN432EQUIPMENTSTORAGE&FLEXSPACE421SOILEDWORKROOM420CLEANWORKROOM419GOWNING418AMEN'SSUB-WAIT418EVS417MULTIPURPOSE/CONSULT405STORAGE404PRACTICEMANAGER403REGISTRATION402GOWNING1407AWOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4DIAGNOSTICRADIOGRAPHY416ULTRASOUND(PoS)423MAMMOGRAPHY(STEREOTATICBIOPSY)431WOMEN'SCIRCULATION425ULTRASOUND424ULTRASOUND(GUIDEDBIOPSY)415HOLDINGBAY2412BCIRCULATION412READINGROOM426OFFICE/READING428IMAGINGIT/DATA429WOMEN'SCIRCULATION425MEN'SCIRCULATION422ELEVATORLOBBY&PUBLICCORRIDOR40034IMAGINGGUESTLOUNGE/WAITING40155555556803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:01:40 PMFP104FOURTHFLOOR PLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. DRAWING NOTES:123SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).3/16" = 1'-0"1FOURTH FLOOR PLANPROVIDE SPRINKLER HEAD UNDER LANDING OF STAIRWELL.45DRY SPRINKLER HEAD.6OPEN TO ABOVE.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529EXAM/CONSULT531PATIENTTOILET527EXAM/CONSULT537TRIAGENURSE539BPATIENTTOILET536SPECIALTYEXAM/TREATMENT/TELEMED535PATIENTTOILET535ALAB534LABDRAW532SPECIMENCOLLECTION533ELEVATORCONTROLROOM500ELEVA500EAPUBLICTOILET501APUBLICTOILET501BOFFICEMANAGER502APATIENTTOILET503STAFFTOILET505ASTAFFBREAKAREA505STAIRVESTIBULE504ASPECIALTYEXAM/TREATMENT506EXAM/CONSULT508EXAM/CONSULT509NURSEWORKAREA517BPROVIDEROFFICE517ASTAFFCIRCULATION517EXAM/CONSULT516EXAM/CONSULT515EXAM/CONSULT514EXAM/CONSULT513CIRCULATION504BBEXAM/CONSULT522EXAM/CONSULT520EXAM/CONSULT519EXAM/CONSULT518SPECIALTYEXAM/TREATMENT526PATIENTTOILET526ASTAFFTOILET525TRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FNURSEWORKAREA517E12STAIR1ST1-3CENTRALSOILEDWORK511PATIENTVITALSALCOVE510STAIRST2-244CIRCULATION517DSTAIR3ST3-5STAFFCIRCULATION517CIRCULATION504REGISTRATION502GUESTWAITING/CIRCULATION50135CIRCULATION504CIRCULATION504REGISTRATION502EVS530EXAM/CONSULT5385555555803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:01 PMFP105FIFTH FLOORPLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. 4PROVIDE UPRIGHT SPRINKLER HEAD AT THE TOP OF THE ELEVATOR SHAFT PER NFPA 13.DRAWING NOTES:123SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).3/16" = 1'-0"1FIFTH FLOOR PLAN5PROVIDE DRY SPRINKLER HEAD.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 TSTSTSTSTSTSTSTSTO FEED 5TH FLOORSPRINKLERSTO FEED 4TH FLOORSPRINKLERSTO FEED 3TH FLOORSPRINKLERSTO FEED 2ND FLOORSPRINKLERS6" REDUCED PRESSURE DETECTORASSEMBLY MAKE: WATTS 957 RPDARUN DRAIN TO BUILDING'SEXTERIOR AND TERMINATE24" ABOVE GRADE WITH 45°GALVANIZED ELBOW TURNEDDOWNRISER VALVE FORFIRST FLOORTO FIRE DEPARTMENTCONNECTION (FDC)6" COMBINEDSERVICE2 1/2" HOSE VALVE AT 4'-0" AFF ONINTERMEDIATE FLOORS. PROVIDEPRESSURE RESTRICTING HOSE VALVEON ALL FLOORS WHERE STATIC SYSTEMPRESSURE EXCEEDS 100 PSI (TYPICAL)2 1/2" HOSE VALVE AT 4'-0" AFF ONINTERMEDIATE FLOORS. PROVIDEPRESSURE RESTRICTING HOSE VALVEON ALL FLOORS WHERE STATIC SYSTEMPRESSURE EXCEEDS 100 PSI (TYPICAL)2 1/2" HOSE VALVE AT 4'-0" AFF ONINTERMEDIATE FLOORS. PROVIDEPRESSURE RESTRICTING HOSE VALVEON ALL FLOORS WHERE STATIC SYSTEMPRESSURE EXCEEDS 100 PSI (TYPICAL)FIRST FLOORSECOND FLOORTHIRD FLOORFOURTH FLOORROOFFIFTH FLOORFSFSFSTSFSTS803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:04 PMFP301RISERDIAGRAM02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1FIRE PROTECTION SCHEMATICGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 1.WATER SERVICE NOTES:BACKFLOW PREVENTER(S) MUST BE A MINIMUM OF 30" ANDMAXIMUM OF 60" ABOVE THE FINISHED FLOOR.2.BACKFLOW PREVENTER(S) INSTALL ABOVE 60", MUST BEPROVIDED WITH AN OSHA APPROVED SCAFFOLD PLATFORM ONSITE FOR REQUIRED TESTING AND INSPECTION OF BACKFLOWDEVICE(S).3.BACKFLOW PREVENTER(S) CLEARANCES:- MINIMUM 36" CLEAR IN FRONT OF DEVICE(S)- MINIMUM 12" CLEAR BEHIND DEVICE(S)- MINIMUM 24" CLEAR ABOVE DEVICE(S)4.DOMESTIC METER HEIGHT LIMITS 18" MIN. - 40" MAX.5.THE BACKFLOW PREVENTER(S) ARE LOCATED IN AN ADEQUATELYHEATED AND LIGHTED AREA TO PREVENT FREEZING AND ALLOWFOR MAINTENANCE AND TESTING OF THE DEVICE(S).6.ALL MATERIAL BEFORE BACKFLOW PREVENTER(S) TO BE BRASS,COPPER OR CEMENT LINED DUCTILE IRON. VICTAULIC GROOVED/ROLLED PIPING AND FITTINGS ARE NOT ACCEPTABLE UPSTREAM OF THE BACKFLOW PREVENTER(S).7.AIR GAP FITTINGS ARE NOT ALLOWED.FINISHED FLOOR60"8"PIPE SUPPORT(TYPICAL)~BY FPC6" REDUCED PRESSURE DETECTOR ASSEMBLY MAKE: WATTS 957 RPDA. PROVIDE A 8x6 FUNNEL FITTING CENTERED UNDER BOTH RPDA AND THE 3/4" DETECTOR RELIEF VALVES. RPZ RELIEF GAP SHALL BE A MINIMUM OF TWO TIMES THE RPZ DISCHARGE OPENING6" OS&Y VALVE WITH TAMPER SWITCH (TYPICAL OF 3)SLEEVE &SEAL (TYPICAL)6" COMBINED WATER SERVICE TO FIRST FLOOR WET SYSTEMTO FIRE DEPARTMENTCONNECTION (FDC)FLOW SWITCH(TYPICAL)4" RISER VALVEW/TRIM (TYPICAL)1" BALL VALVE FOR INSPECTORS TEST CONNECTION, PIPE TOEXTERIOR (TYPICAL)CHECK VALVETO STANDPIPES6" OS&Y VALVE WITHTAMPER SWITCH6X4 TEE TO DOMESTICSERVICETERMINATE 8" DRAIN AT BUILDING'S EXTERIOR, 12"ABOVE GRADE WITH TURNED DOWN ELBOW, 12x12 SPLASH BLOCK, BUG SCREEN AND FLAPPER VALVEBDAOBSTRUCTIONCEILINGWALLA>(D-8")+ BD<30"PER NFPA 13SPRINKLERS SHALL BE POSITIONED AWAYFROM OBSTRUCTIONS IN ACCORDANCEWITH NFPA 13.NOTES:1.NOTE:1. SLEEVE AND FIRE CAULK ALL FLOOR PENETRATIONS.2. PROVIDE HOE CONNECTION ON INTERMEDIATE FLOORS.4" CONTROL VALVE WITHTAMPER SWITCH. PROVIDEPRESSURE REDUCING VALVEWHERE PRESSURE EXCEEDS175 PSI2 1/2" HOSE VALVE AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTINGHOSE VALVE ON ALL FLOORS WHERESTATIC SYSTEM PRESSURE EXCEEDS100 PSISTANDPIPE AND DRAINRISERS SHALL BEEXTENDED UPWARD FOREACH STORY ANDSECURELY CAPPED AT THETOPRUN 2 1/2" SPRINKLER SYSTEM DRAINDOWN THROUGH ALL FLOORS BELOW TOGROUND FLOOR. RUN DRAIN TO BUILDING'SEXTERIOR AND TERMINATE 24" ABOVEGRADE WITH 45° GALVANIZED ELBOWTURNED DOWN1" UNION WITHRESTRICTING ORIFICE2 1/2" DRAIN RISERAUX. DRAIN VALVEINSPECTOR'S TEST VALVEFLOW SWITCHPRESSURE GAUGE4" FP TO SPRINKLERSYSTEM AS SHOWN ONFLOOR PLANS6" COMBINED(SPRINKLER ANDSTANDPIPE) RISERCHECK VALVETEMPORARYCONN. PLUGVALVE ENDWHEN NOT IN USE1" SIGHT GLASS1" VALVE NOTOVER 7'-0"ABOVE FINISHEDFLOORWET SYSTEMBRANCH LINE1" BALL VALVEDRY ORPREACTIONSYSTEMEXTERIOR BLDG. WALLRETURN BEND FORDRY OR PREACTIONSYSTEMSMOOTH BORE, CORROSIONRESISTANT OUTLET GIVING FLOWEQUIVALENT TO ONE SPRINKLER1" THICK 24"x24"CONC. SPLASHBLOCKCAULKING SEALANT1" 45° ELBOWGRADE/ROOFC PIPE24"LFINISHED GRADEEXTERIOR BLDG. WALLCAULK AROUNDWALL ESCUTCHEONFIRE DEPARTMENTCONNECTION GRAPHICSIGNFDC APPROX. 3'-0"ABOVE FINISHEDGRADE3/4" BALL DRIP VALVE W/3/4"COPPER DRAIN TO EXTERIOR ORFLOOR DRAINCAULK SEALANTFIRE PROTECTIONFEED MAINANCHORPIPE TOWALLCHECK VALVENOTE:VERIFY SIZE AND TYPE OF FIRE DEPARTMENT CONNECTION (FDC) WITH LOCAL FIRE MARSHALL.FIN. FLOOR2 1/2" FPFROM SYSTEM48"2 1/2" ANGLE VALVESTANDPIPE IN STAIRWELL803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:07 PMFP501DETAILS02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1FIRE SERVICE2SPRINKLER OBSTRUCTION DETAIL3STANDPIPE (COMBINED SYSTEM)4INSPECTOR TEST DETAIL6FIRE DEPARTMENT CONNECTION5FIRE HOSE CABINETREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 1. THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALLCONFORM TO THE PLUMBING CODE AND AUTHORITIES HAVINGJURISDICTION. IN CASE OF CONFLICTS WITH CODES, DRAWINGS, ORSPECIFICATIONS, THE MOST STRINGENT SHALL PREVAIL.2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFYTHE EXACT LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALLUTILITIES AND PIPING, AND SHALL IMMEDIATELY NOTIFY THE ARCHITECTOF ANY DISCREPANCIES.3. THESE DRAWINGS DO NOT INCLUDE ALL NECESSARY SAFETYREQUIREMENTS. CONTRACTOR TO COMPLY TO THE SAFETYREQUIREMENTS SET FORTH BY THE LOCAL AUTHORITIES HAVINGJURISDICTION.4. THESE DRAWINGS ARE FOR BIDDING PURPOSES ONLY. THEY AREESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT MANY OFFSETS,BENDS, UNIONS, SPECIFIC FITTINGS AND EXACT LOCATIONS ARE NOTINDICATED.5. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOIDINTERFERENCE WITH ELECTRICAL EQUIPMENT, MECHANICAL EQUIPMENTAND STRUCTURAL FRAMING, SKYLIGHTS, ETC.6. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILINGACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLANAND ELECTRICAL LIGHTING PLAN.7. COORDINATE ALL LOCATIONS, SIZES AND ELEVATIONS OF ALL SLEEVESTHROUGH WALLS, BEAMS, SLABS AND FOOTING WITH STRUCTURAL ANDARCHITECTURAL DRAWINGS. ALL PIPES SLEEVING THROUGH BEAMS ORFOOTINGS SHALL HAVE A SLEEVE DIAMETER OF TWO PIPE SIZES OVERTHE PIPE PASSING THROUGH THE FOOTING OR PER STRUCTURALDRAWING. THE MOST STRINGENT SHALL PREVAIL.8. BEFORE FABRICATION OR INSTALLATION, THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF ALL MECHANICAL/PLUMBING EQUIPMENT AND EQUIPMENT PROVIDED UNDER ANOTHER SECTION OF SPECIFICATIONS. EXACT ROUGH-IN LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED IN FIELD.9. PIPING SUPPORTS. ALL PIPING TO BE SUPPORTED WITH HANGERS ANDBRACKETS WHICH PROVIDE ISOLATION FROM FRAMING. CONTACTBETWEEN PIPE AND SUPPORT TO BE LINED WITH PLASTIC OR FELT.10. ALL FLOOR AND WALL PENETRATIONS MUST BE SEALED WATERTIGHT AND VERMIN PROOF.11. EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURESSHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.12. SEE ARCHITECTURAL DRAWINGS FOR HANDICAP FIXTURE LOCATIONS AND MOUNTING HEIGHTS. INSULATE ALL EXPOSED HOT WATER AND DRAIN PIPING BELOW HANDICAP LAVATORIES AND SINKS WITH INSULATING WRAP AND OFFSET P-TRAP AGAINST WALL. ALL FLUSH VALVES FOR HANDICAP SHALL BE LOCATED ON HANDICAP WHEELCHAIR ACCESS SIDE OF STALL.13. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THECONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS OFEQUIPMENT, CABINETS, ETC., WITH THE ARCHITECT PRIOR TO ANYINSTALLATION.14. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHEREQUIPMENT SHOWN IN WALLS OR ABOVE NON-ACCESSIBLE CEILINGSSHALL BE INSTALLED BEHIND AN ACCESS PANEL. COORDINATELOCATION AND SIZE WITH ARCHITECT.15. PLUMBING CONTRACTOR SHALL COORDINATE COMPLETE PLUMBINGINSTALLATION AND REQUIREMENTS PRIOR TO SUBMITTING BID WITH ALLLOCAL DISTRICTS AND GOVERNING AUTHORITIES. INCLUDE ALL FINDINGSWITHIN THE BASE BID.16. ALL DRY SYSTEM PIPING SHALL BE INSTALLED WITH PROPER PITCH FORDRAINING OF SYSTEM.17. DO NOT SHUT DOWN ANY SYSTEM WITHOUT BUILDING OWNER'S PRIOR WRITTEN APPROVAL. FOLLOW ALL OWNER REQUIREMENTS AND SHUT DOWN PROCEDURES AS WELL AS ALL REQUIREMENTS OF THIS PROJECT'S CONTRACT DOCUMENTS (PLANS AND SPECIFICATIONS).18. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ROOF WORKTHAT IS REQUIRED AS PART OF THIS CONTRACT. ALL ROOF WORKSHALL BE PERFORMED SUCH THAT ALL EXISTING ROOF WARRANTEESARE MAINTAINED.19. PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE ANDFEDERAL CODES. OBTAIN ALL REQUIRED PERMITS. COORDINATE ALLWORK WITH LOCAL FIRE MARSHAL.20. FIELD VERIFY EXACT LOCATION, COMPOSITION AND CONDITION OF ALLPIPING, VALVES AND SYSTEMS AS REQUIRED FOR WORK OF THECONTRACT.21. PROVIDE ALL REQUIRED EXCAVATION, BACKFILL AND COMPACTION FORALL UNDERGROUND WORK.22. REFER TO ARCHITECTURAL DRAWINGS AND THE PROJECT SPECIFICATIONS FOR PROJECT PHASING REQUIREMENTS.23. WHERE PIPING IS LOCATED OVER FOOTINGS AND/OR OTHERUNDERGROUND STRUCTURES, ROLL DOWN AS REQUIRED TO CONNECT TO SYSTEMS NOTED. PROVIDE ALL REQUIRED OFFSETS, FITTINGS ANDCONNECTIONS.24. PROVIDE BALANCING VALVE ARRANGEMENTS AT EACH LOCATION WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS INTERSECT.25. PITCH ALL SANITARY/WASTE, INDIRECT WASTE AND STORM PIPING AS FOLLOWS: PIPING 2 1/2" AND SMALLER, PITCH AT 2 PERCENT (1/4" PER FOOT) MINIMUM,PIPING 4" AND LARGER, PITCH AT 1 PERCENT (1/8" PER FOOT) MINIMUM.26. SUBMITTALS AND SHOP DRAWINGS: AS SOON AS POSSIBLE AND WITHIN21 DAYS AFTER AWARD OF THE CONTRACT, AND BEFORE THEIRPURCHASE, THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT 6BOUND BOOKLETS FOR APPROVAL AND CONTAINING A COMPLETE LISTOF MATERIALS, SPECIALTIES AND EQUIPMENT HE IS TO FURNISH FORTHE INSTALLATION. ALL SUBMITTALS SHALL BE MADE AT ONE TIME. NODEVIATION OF PLUMBING FIXTURES WILL BE ACCEPTED. BASED ONAPPROVAL OF ALTERNATE PRIOR TO BID.27. COORDINATE PLUMBING SYSTEMS WITH WORK OF ALL OTHER TRADESPRIOR TO ANY FABRICATION OR INSTALLATION.28. COORDINATE LOCATIONS OF ALL ROOF OPENINGS WITH STRUCTURAL,MECHANICAL, AND ARCHITECTURAL PLANS PRIOR TO ANY INSTALLATION.29. COORDINATE ALL VENT TERMINATIONS ABOVE ROOF WITH HVACCONTRACTOR. ALL VENT TERMINATIONS ABOVE ROOF SHALL BE AMINIMUM 25'-0" (HEALTHCARE) AWAY FROM ANY HVAC OUTSIDE AIR INTAKE (ROOFTOP UNIT, LOUVER, ETC). OR AT LEAST 3 FEET ABOVE WINDOW, DOOR, OPENING, AIR INTAKE OR VENT SHAFT.30. PROVIDE HOSE BIBB (HB) UNDER LAVATORY IN ALL TOILET ROOMSWITH FLOOR DRAINS.31. PROVIDE SCHEDULE 40 BLACK STEEL PIPE SLEEVES FOR ALLUNDERGROUND PIPING PASSING THROUGH OR UNDER FOOTINGS, WALLS,FOUNDATION WALLS, SLABS FLOORS AND/OR UNDERGROUND STRUCTURES. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.32. PLATFORMS, CURBS, AND FLUSHINGS FOR PLUMBING EQUIPMENT SHALLBE AS INDICATED ON THE STRUCTURAL AND ARCHITECTURAL PLANS,UNLESS NOTED OTHERWISE, COORDINATE EXACT SIZES OF REQUIREDOPENINGS AND SUPPORTS FOR FURNISHED EQUIPMENT.33. MAINTENANCE LABEL SHALL BE AFFIXED TO ALL PLUMBING EQUIPMENTAND A MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER'SREPRESENTATIVE WITH A COPY PROVIDED TO BUILDING COMMISIONING AGENT AND INCLUDED IN PROJECT O&M MANUAL SUBMISSION AT COMPLETION OF PROJECT.34. ALL HOSE BIBBS, WALL HYDRANTS AND MOP SERVICE BASINS SHALLBE EQUIPPED WITH APPROVED, PROPERLY INSTALLED ATMOSPHERIC TYPEVACUUM BREAKERS.35. COORDINATE WITH ELECTRICAL TRADE PRIOR TO ORDERING ELECTRICALLY OPERATED EQUIPMENT FOR AVAILABLE VOLTAGES AT EQUIPMENTLOCATIONS.36. PIPE SIZE DISCREPANCIES BETWEEN FLOOR PLANS AND RISER DIAGRAMSLARGER PIPE SIZE INDICATED WILL TAKE PRECEDENCE.37. THESE PLANS INDICATE APPROXIMATE ROUGH-INS ONLY FOR EQUIPMENTNOT IN THIS SECTION (N.I.T.S.) EXACT ROUGH-IN DIMENSIONS MUST BEOBTAINED FROM THE EQUIPMENT MANUFACTURER.38. ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS PIPE UNLESSOTHERWISE INDICATED ON DRAWINGS.39. UNIONS SHALL BE PROVIDED AND INSTALLED AFTER EACH SCREW-TYPEVALVE AND PRIOR TO EQUIPMENT CONNECTIONS.40. THE PLUMBING CONTRACTOR SHALL COORDINATE ALL REQUIREMENTSFOR ALL POINTS OF CONNECTION WITH THE GENERAL CONTRACTOR ANDOTHER TRADES PRIOR TO BID.41. CONTRACTOR SHALL PROVIDE ALL VALVES AND BACKFLOW PREVENTIONDEVICES AS REQUIRED BY STATE AND LOCAL CODES.42. DRAINS SHALL BE INSTALLED AT THE LOW POINT OF THE FLOORS,UNLESS OTHERWISE NOTED.43. OFFSETS IN PIPING AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NOADDITIONAL COST TO THE OWNER.44. PROVIDE RPZ TYPE BACKFLOW PREVENTER AND ISOLATION VALVES ONALL MAKE-UP WATER LINES EQUAL TO WATTS LF909 (SAME SIZE AS LINE).COORDINATE WITH MECHANICAL DRAWINGS. PROVIDE CAP DOWNSTREAMOF RPZ FOR HVAC CONTRACTOR. MOUNT DEVICE AS HIGH ASPOSSIBLE. PROVIDE DRAIN FROM RPZ'S RELIEF VALVE ANDTERMINATE AT NEAREST FLOOR DRAIN.45. PROVIDE CLEAN-OUTS AT THE BASE OF ALL STORM, SANITARY, ANDWASTE STACKS.46. MINIMUM SIZE OF SANITARY/WASTE PIPING BELOW SLAB SHALL BE 3".47. PROVIDE FLOOR DRAIN TRAP SEALER ON ALL FLOOR DRAINS ASSPECIFIED.48. COORDINATE AND SCHEDULE WORK AND SHUTDOWNS WITH THE OWNERAND OTHER TRADES PRIOR TO DEMOLITION.49. PLUMBING SYSTEMS AND ALL COMPONENTS THAT ARE DESIGNED AND/ORINTENDED TO DELIVER POTABLE WATER FOR HUMAN CONSUMPTION SHALL BE THIRD-PARTY TESTED AND CERTIFIED FOR NOT EXCEEDING THE MAXIMUM ALLOWABLE LEAD CONTENT PER THE NSF/ANSI 372 STANDARD.50. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THEEQUIPMENT MANUFACTURER'S RECOMMENDATIONS AND APPLICABLECODES, PROVIDE ALL FITTINGS, VALVES, AND OTHER DEVICES REQUIREDFOR A COMPLETE WORKABLE INSTALLATION.51. INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS,FLANGES AND OTHER APPURTENANCES REQUIRING ACCESS AREACCESSIBLE.52. PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, SLABS ANDDECKS AS REQUIRED FOR WORK SHOWN. COORDINATE ALL WORK WITHOWNER AND GENERAL CONTRACTOR.53. PIPES SHALL BE SUPPORTED AND BRACED PER SMACNA "GUIDELINESFOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBINGPIPING SYSTEMS."GENERAL NOTES:GENERAL SITE/UTILITY NOTES:1. THE PLUMBING CONTRACTOR SHALL PROVIDE THE WATER, SEWER ANDSTORM DRAIN SYSTEMS TO A POINT OF CONNECTION 5'-0" OUTSIDE OFTHE BUILDING AND SHALL MEET THE INVERT ELEVATION SHOWN ON THECIVIL DRAWINGS. PIPING BEYOND THIS POINT IS SPECIFIED UNDERANOTHER SECTION OF THE SPECIFICATION AND SHALL BE AS SHOWNON THE CIVIL DRAWINGS.2. THE CONTRACTOR SHALL MAKE ALL ARRANGEMENTS WITH UTILITYCOMPANIES FOR SERVICE AND CONNECTION AND SHALL MAKEAPPLICATION FOR SERVICE AND PERMITS IN THE NAME OF THE OWNERAND SHALL PAY ALL FEES AND CHARGES INCLUDING THE COST OFVAULTS AND METERS. CONTRACTOR SHALL MAKE VARIATIONS PER UTILITYCOMPANY'S REQUIREMENTS WITHOUT CHARGING EXTRA TO THE BIDCONTRACT.3. ALL EXTERIOR GAS COCKS, WATER SHUTOFF VALVES AND/OR SEWERCLEAN OUTS BELOW GROUND SHALL BE INSTALLED IN YARD BOXESWITH THE COVERS CONSPICUOUSLY MARKED "GAS", "WATER", AND"SEWER" RESPECTIVELY.4. CONNECT TO SITE PIPING OUTSIDE BUILDING AS SHOWN. PROVIDE ALLREQUIRED OFFSETS, FITTINGS AND CONNECTIONS. FIELD VERIFY EXACTLOCATION, DEPTH AND COMPOSITION OF SITE SERVICES ANDCOORDINATE ALL WORK WITH SITE CONTRACTOR.5. FIELD VERIFY ALL UNDERGROUND VALVES AND PIPING AS REQUIRED FORWORK SHOWN.6. WATER OR WASTE PIPE BELOW GRADE OUTSIDE THE BUILDING SHALLHAVE MINIMUM COVER AS RECOMMENDED BY LOCAL AUTHORITIES.7. NO GAS PIPING SHALL BE INSTALLED IN OR ON THE GROUND UNDERANY BUILDING OR STRUCTURE AND ALL EXPOSED GAS PIPING SHALL BEKEPT AT LEAST 6" ABOVE GRADE.WHHBTSFSGIWAWAVSYMBOLACID WASTE PIPING (AW)ACID VENT PIPING (AV)NATURAL GAS PIPING (G)INDIRECT WASTE PIPING (IW)SANITARY/WASTE PIPING (SAN/W)VENT PIPING (V)DESCRIPTIONAGWO2N2VACVACUUM PIPING (VAC)NITROGEN PIPING (N2)OXYGEN PIPING (O2)GREASY WASTE PIPING (GW)COMPRESSED AIR PIPING (A)VALVE WITH TAMPER SWITCHFLOW SWITCHWALL HYDRANTHOSE BIBBTHERMOMETERCLEANOUT (CO)PLUMBING SYMBOLS LISTREMOVE TO THIS POINTNEW TO EXISTING CONNECTIONEXISTING PIPINGWORK TO BE REMOVEDHW RECIRCULATION PIPING (HWR)HOT WATER PIPING (H)COLD WATER PIPING (C)STORM PIPING (ST)P-TRAPDROP CONNECTIONELBOW UP, ELBOW DOWNUNIONCAP OR PLUGCHECK VALVESHUT OFF VALVEBALANCE VALVEPRESSURE GAGESTRAINERBACKFLOW PREVENTERFLOOR DRAIN (FD)SOLENOID VALVEREGULATING VALVEPIPE CONTINUATION (SINGLE LINE)PIPE CONTINUATION (DOUBLE LINE)BUTTERFLY VALVEMETERMROOF DRAIN (RD)PUMPPRESSURE REDUCING VALVEHCHWRVSTWVENT THROUGH ROOF (VTR)LIQUEFIED PETROLEUM GAS PIPING (LPG)LPGVTRDECKPLATE CLEANOUT (DPCO)NOTE: NOT ALL SYMBOLS ARE NECESSARILY USED SYMBOL DESCRIPTIONFILTERED COLD WATER PIPING (FC)FCNOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE PLUMBING SCOPE. PIPING MATERIAL, WATER QUALITY, HOT WATER HEATER EFFICIENCY, LEGIONELLA CONTROL, WATER SENSE FIXTURES, FIXTURE WATER CONSUMPTION, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 220800 AND 019113 FOR COMMISSIONING REQUIREMENTS.REQUIRED 2020 IECC ENERGY CONSERVATION COMPLIANCECODE SECTIONCOMPLIANCEC303.3 OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER BY CONTRACTOR FOR ALL EQUIPMENTC401.2 BUILDING COMPLIES WITH THE APPLICABLE SECTIONS OF CODE BASED ON METHOD 2C402.5 REFERENCE ARCHITECTURAL PLANS FOR AIR LEAKAGE CRITERIA C403.2.1HVAC LOAD SIZING HAS BEEN PERFORMED IN THE CARRIER HAP PROGRAM, USING RTS (HEAT BALANCE) METHODOLOGYC403.2.3 ALL HVAC EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE MECHANICAL DOCUMENTSC403.2.4 REQUIRED HVAC CONTROLS SHALL BE PROVIDED, REFERENCE MECHANICAL DOCUMENTSC403.2.4.3MOTORIZED DAMPERS PROVIDED FOR EXHAUST AND OUTSIDE AIR INTAKES GREATER THAN 300 CFM OR IN BUILDINGS 3 STORIES OR LESSC403.2.9.1 DUCT IS REQUIRED TO BE INSULATED TO THE INDICATED MINIMUM LEVEL, REFERENCE MECHANICAL DOCUMENTSC403.2.9.3 INSTALLING CONTRACTOR SHALL ENSURE THAT ALL AIR DISTRIBUTION COMPONENTS ARE PROPERLY SEALEDC403.2.9.5 DUCT SIZING AND DUCT DESIGN HAS BEEN PERFORMED, REFERENCE MECHANICAL DOCUMENTSC403.2.10 ALL PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE MECHANICAL / PLUMBING DOCUMENTSC403.2.11 MECHANICAL SYSTEMS SHALL BE COMMISSIONED AS REQUIREDC404.2 ALL WATER HEATING EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE PLUMBING DOCUMENTSC404.4 ALL DOMESTIC HOT WATER PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE PLUMBING DOCUMENTSC405.2 LIGHTING CONTROL CRITERIA HAS BEEN MET, REFERENCE ELECTRICAL DOCUMENTSC405.5 EXTERIOR LIGHTING TOTAL POWER DOES NOT EXCEED THE ALLOWANCE, REFERENCE ELECTRICAL DOCUMENTSC405.6 ELECTRICAL POWER HAS BEEN PROVIDED PER THE CODE REQUIREMENTS, REFERENCE ELECTRICAL DOCUMENTSC408.2.2 INSTALLING CONTRACTOR SHALL TEST AND BALANCE ALL HVAC SYSTEMS AND PROVIDE REPORT TO ENGINEERMECHANICAL DESIGN CONFORMS TO 2020 IECC AND IMC CODE REQUIREMENTSC103.2.1REFERENCE ARCHITECTURAL PLANS FOR FENESTRATION U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSREFERENCE ARCHITECTURAL PLANS FOR AREA-WEIGHTED U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSC103.2.2C103.2.3C103.2.4C103.2.5C103.2.6C103.2.7C103.2.8C103.2.9C103.2.10C103.2.11C103.2.12REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR DUCT AND PIPE INSULATION MATERIALS, ARCHITECTURAL DOCUMENTS FOR ALL OTHER INSULATION MATERIALSREFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENTAMD SYSTEM CONTROLSREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT HORSEPOWER AND CONTROLSREFERENCE MECHANICAL AND PLUMBING SPECIFICATIONS FOR SEALING AND INSULATION LOCATIONSREFERENCE ELECTRICAL DOCUMENTS FOR LIGHTING FIXTURE SCHEDULE AND CONTROLSREFERENCE ELECTRICAL DRAWINGS FOR DAYLIGHTING ZONESREFERENCE MECHANICAL SPECIFICATIONS FOR AIR SEALING DETAILS803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:43 PMP001LEGEND &GENERALNOTES02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGTO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT, THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE INTERNATIONAL ENERGY CODE, AS ADOPTED BY THE STATE.ENERGY CONSERVATION CODE COMPLIANCE STATEMENTREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.12345ABCE3.8F3.914W3W5W67867W8113"1273"3"W888107123"3"8"867WV2"74"4"4"1313131313W1W3"98586764"4"4"5WW5W84"4"8764"WW3"3"888888884"4"4"7252228876884"8103"8567124"4"3"84"4"3"4"10104"8"8"V2"4"134"4"W74"154"1554168"6"STST6"STSTST4"ST4"14144"6"6"8"8"4186"17555VESTIBULE100V2LOBBY/WAITING101LOBBY/WAITING101RECEPTION101BTRIAGE/INTERVIEW106CLEANHOLDING107STAFFBREAK102STAFFTOILET103SHAREDPROVIDEROFFICE104PoSPATIENTTOILET105CSUB-WAITING105BEXAM114EXAM115EXAM116TREATMENT117STORAGE144MECHANICAL145WATERSERVICE146CIRCULATION105EXAM118RADIOLOGY(X-RAY)119EXAM113EXAM112EXAM121EXAM120SOILEDWORK111MAINSERVER140BUILDINGMAINTENANCETOILET/SHOWER138AEMERGENCYEQUIPMENTROOM141MAINELECTRICAL142SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128CORRIDOR122CLEANLINENHOLDING137WASTEHOLDING136STAFFBREAK133CLEANSUPPLY134STAFFTOILET131LABORATORY126REGISTRATION124WAITING/CIRCULATION123MAINLOBBY100EVS125PUBLICTOILET100APUBLICTOILET100BMAINLOBBY100CORRIDOR122CIRCULATION105STATLAB/MED110VITALSALCOVE105AVESTIBULE100V1CORRIDOR143CORRIDOR14358"8"4"4"24"W4"W3"3"4"2"4"134"3"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:56 PMP100FOUNDATONPLAN02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FOUNDATION PLANNDRAWING NOTES:1ELEVATOR SUMP PUMP (ESP-1). REFER TO DETAIL DRAWING(S).24" SANITARY/WASTE UP.3CONNECT 8" SANITARY SEWER TO 8" BY CIVIL CONTRACT AT INVERT -5.00'.4SLEEVE AND SEAL.5UP TO DECK PLATE CLEANOUT.64" SANITARY UP TO WATER CLOSET.72" VENT UP.81 1/2" WASTE UP TO SINK/LAVATORY. INCREASE TO 3" WASTE ON ALL UNDERGROUND HORIZONTAL RUNS.91 1/2" WASTE UP TO ELECTRIC WATER COOLER. INCREASE TO 3" WASTE ON ALL UNDERGROUND HORIZONTAL RUNS.101 1/2" WASTE UP TO BOTTLE FILLER. INCREASE TO 3" WASTE ON ALL UNDERGROUND HORIZONTAL RUNS.111 1/2" WASTE UP TO BACK-TO-BACK SINKS/LAVATORIES. CONNECT 1 1/2" WASTE TO EACK SINK/LAVATORY. INCREASE TO 3" WASTE ON ALL UNDERGROUND HORIZONTAL RUNS.123" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.134" WASTE (WITH TRAP) UP TO FLOOR DRAIN.FEE = 0.00'144" STORM (PRIMARY SYSTEM) UP.156" STORM (PRIMARY SYSTEM) UP.16CONNECT 8" STORM TO 8" BY CIVIL CONTRACT AT INVERT -5.00'.176" COMBINED WATER SERVICE UP.18CONNECT 6" COMBINED WATER SERVICE TO 6" BY CIVIL CONTRACT.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.12345ABCE3.8F3.9WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEVS109EXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1HOLDING/MAIL100CCIRCULATION105CIRCULATION105VITALSALCOVE105ASUB-WAITING105BSTAIR2ST2-1CIRCULATION105CORRIDOR122SPECIMENTOILET127BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125CORRIDOR143TREATMENT117EXAM113STATLAB/MED110CLEANHOLDING107SHAREDPROVIDEROFFICE104STAFFBREAK102BUILDINGMAINTENANCETOILET/SHOWER138A2DPCO4" FD-A4" FD-A4" FD-A 4" FD-A1212112DPCODPCODPCODPCODPCOW651 1/2"W44WWWW4441 1/2"2"1 1/2"2"1 1/2"1 1/2"2"1 1/2"4442"441 1/2"4101041 1/2"61 1/2"1 1/2"2"410441144W3"WW73"34"4"431043104" FD-ADPCODPCOW1 1/2"2"1 1/2"2"1 1/2"2"2"W1 1/2"444448833223104"1 1/2"34"4"4"4"4"S T 1418121314181913204"4"4"ST6"6"916181715318176"6"STST1621224" FD-ADPCODPCODPCODPCODPCO4"2"4"4"4"2"1 1/2"31 1/2"24"4" FD-A4"4"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:08 PMP101FIRST FLOORPLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FIRST FLOOR PLAN - SANITARY/WASTE AND STORMDRAWING NOTES:124" SANITARY/WASTE DOWN.34" SANITARY/WASTE UP. GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.41 1/2" WASTE UP TO SINK/LAVATORY. 51 1/2" WASTE UP TO ELECTRIC WATER COOLER. 61 1/2" WASTE UP TO BOTTLE FILLER.73" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.82" WASTE (WITH TRAP) UP TO SHOWER.9104" SANITARY UP TO WATER CLOSET.2" VENT UP.111 1/2" WASTE UP TO BACK-TO-BACK SINKS/LAVATORIES. CONNECT 1 1/2" WASTE TO EACH SINK/LAVATORY.124" STORM STACK (PRIMARY SYSTEM) UP AND DOWN.134" STORM (SECONDARY SYSTEM) UP.14TERMINATE 4" STORM (SECONDARY SYSTEM) AT BUILDING'S EXTERIOR WITH ZURN ZARB199 DOWNSPOUT NOZZLE ON FACE OF BUILDING.15166" STORM (SECONDARY SYSTEM) UP.17TERMINATE 6" STORM (SECONDARY SYSTEM) AT BUILDING'S EXTERIOR WITH ZURN ZARB199 DOWNSPOUT NOZZLE ON FACE OF BUILDING.18SLEEVE AND SEAL.194" STORM (PRIMARY SYSTEM) UP.204" STORM (PRIMARY SYSTEM) DOWN.6" STORM (PRIMARY SYSTEM) UP.6" STORM (PRIMARY SYSTEM) DOWN.214" SANITARY/WASTE STACK UP AND DOWN.224" SANITARY UP WITHIN CHASE ON SECOND FLOOR.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223STAIRST2-2CORRIDOR232RESPITE/LACTATION240STAFFTOILET237STAIR2ST2-1MAINLOBBY100RESPITE/MEDITATION241OFFICE238UnoccupiedUnoccupiedCIRCULATION228DENTALOFFICE230WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203CIRCULATION207NURSE214PHYSICIANOFFICE/DICTATION213LAB221MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204EDUCATION/CONFERENCE234IT/ELEC2431121W3MULTIPURPOSE/ACTIVITY235RESPITE/LACTATION239STAFFTOILET236TELMED233WWW1 1/2"4"1 1/2"4"2"WW654666451 1/2"6661 1/2"1 1/2"2"66W2"2"W66W64"4"666544"4"5461 1/2"4"1 1/2"666W1 1/2"2"WW662"6645654W1 1/2"4"4"4"4566547131313STAFFBREAK242STAFFBREAK242CIRCULATION207CIRCULATION228WALKINGTRACK200ELEVA200EAELEVB200EBSTAIR1ST1-24"1415ST13STST4"4"1514STST1686"6"1110664559121 1/2"4"1 1/2"STST6"6"10111681 1/2"62"1 1/2"1 1/2"6WW66661 1/2"6W2"2"1 1/2"1 1/2"4"4"4"3"1 1/2"2"1 1/2"2"4"2"4"4"4"4"1 1/2"1 1/2"64"17803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:20 PMP102SECONDFLOOR PLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1SECOND FLOOR PLAN - SANITARY/WASTE AND STORMDRAWING NOTES:1114" SANITARY/WASTE STACK UP AND DOWN.24" SANITARY/WASTE UP.34" SANITARY/WASTE DOWN.GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.44" SANITARY UP TO WATER CLOSET.52" VENT UP.61 1/2" WASTE UP TO SINK/LAVATORY. 71 1/2" WASTE UP TO ELECTRIC WATER COOLER. 893" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.10121 1/2" WASTE UP TO BACK-TO-BACK SINK/LAVATORY. CONNECT 1 1/2" WASTE TO EACH SINK/LAVATORY.134" STORM UP TO ROOF DRAIN (RD-A).144" STORM (PRIMARY SYSTEM) DOWN.154" STORM (SECONDARY SYSTEM) DOWN.166" STORM (PRIMARY SYSTEM) DOWN.6" STORM (SECONDARY SYSTEM) DOWN.6" STORM (PRIMARY SYSTEM) UP.6" STORM (SECONDARY SYSTEM) UP.17CONNECT 4" SANITARY/WASTE TO WALL MOUNTED WATER CLOSET. RUN 4" SANITARY/WASTE IN CHASE WALL (TO AVOID BEAM BELOW)AND DOWN TO FIRST FLOOR CEILING.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8ELEC/DATA323STAIR2ST2-1STAIR1ST1-3W3211STAFFBREAKAREA305STAFFTOILET305ASPECIMENCOLLECTION333876746W4"1 1/2"4"1 1/2"4"4"4"96765491 1/2"4"41 1/2"10741 1/2"1 1/2"92"41 1/2"4"44WW4467WW4"4"4"1 1/2"4"467674446741 1/2"W413111412EXAM/CONSULT327TRIAGENURSE339BPATIENTTOILET336SPECIALTYEXAM/TREATMENT/TELEMED335PATIENTTOILET335ALAB334LABDRAW332GUESTWAITING/CIRCULATION300PUBLICTOILET300BPUBLICTOILET300AREGISTRATION301CENTRALSOILEDWORK311PATIENTVITALSALCOVE310EXAM/CONSULT309SPECIALTYEXAM/TREATMENT303OFFICEMANAGER301APATIENTTOILET302EXAM/CONSULT307EXAM/CONSULT306EXAM/CONSULT308NURSEWORKAREA317BPROVIDEROFFICE317AEXAM/CONSULT316EXAM/CONSULT315EXAM/CONSULT314EXAM/CONSULT313CIRCULATION304EXAM/CONSULT318EXAM/CONSULT319EXAM/CONSULT320EXAM/CONSULT321EXAM/CONSULT322CENTRALCLEANWORK312EXAM/CONSULT328EXAM/CONSULT331EXAM/CONSULT328PROVIDEROFFICE339AEXAM/CONSULT329EVS330NURSEWORK339PATIENTTOILET327SPECIALTYEXAM/TREATMENT326PATIENTTOILET326ATRIAGENURSE324PROVIDEROFFICE317FNURSEWORKAREA317BCIRCULATION304CIRCULATION304STST6"6"14131211W4"1 1/2"4"4764"W476104"4"4"441 1/2"2"2"44152"NURSEWORKAREA317ECIRCULATION3044"4"WW2"4"41 1/2"4"3"21 1/2"1 1/2"4"2"1 1/2"W2"631 1/2"STAFFTOILET325803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:33 PMP103THIRD FLOORPLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1THIRD FLOOR PLAN - SANITARY/WASTE AND STORMDRAWING NOTES:4GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.1 1/2" WASTE UP TO SINK/LAVATORY. 1 1/2" WASTE UP TO ELECTRIC WATER COOLER. 564" SANITARY UP TO WATER CLOSET.72" VENT UP.14" SANITARY/WASTE STACK UP AND DOWN.24" SANITARY/WASTE UP.34" SANITARY/WASTE DOWN.81 1/2" WASTE UP TO BACK-TO-BACK LAVATORY/BOTTLE FILLER. CONNECT 1 1/2" WASTE TO LAVATORY AND BOTTLE FILLER.91 1/2" WASTE UP TO BACK-TO-BACK SINKS/LAVATORIES. CONNECT 1 1/2" WASTE TO EACH SINK/LAVATORY.103" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.116" STORM (PRIMARY SYSTEM) DOWN.126" STORM (SECONDARY SYSTEM) DOWN.136" STORM (PRIMARY SYSTEM) UP.146" STORM (SECONDARY SYSTEM) UP.152" WASTE UP TO DISINFECTION UNIT.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445EVS439STAIR1ST1-3STAIR2ST2-1PROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438PROCEDUREROOM440RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402WOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418ACIRCULATION412HOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS41723W1311 1/2"4"4"1 1/2"4"2"1 1/2"1 1/2"4"681154664"66452"661 1/2"4"WWWWW6544144"6W54"61 1/2"6WW66666WW6W1 1/2"4"4"5466WW4"4569544"4"7W1 1/2"4"45W1 1/2"2"6451 1/2"1312105STST131210116"6"ELEVATORLOBBY&PUBLICCORRIDOR400661 1/2"4"662"2"1 1/2"1 1/2"4"664"4"62"4"6W6661 1/2"64"62"2"4"4"4"WOMEN'SCIRCULATION4251 1/2"1 1/2"1 1/2"1 1/2"1 1/2"21 1/2"2"1 1/2"1 1/2"2"1 1/2"W4"4"61 1/2"WOMEN'SSUB-WAIT409RESULTSALCOVE410803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:46 PMP104FOURTHFLOOR PLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FOURTH FLOOR PLAN - SANITARY/WASTE AND STORMDRAWING NOTES:GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.44" SANITARY UP TO WATER CLOSET.52" VENT UP.61 1/2" WASTE UP TO SINK/LAVATORY. 71 1/2" WASTE UP TO ELECTRIC WATER COOLER. 83" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.14" VENT UP, 4" SANITARY/WASTE DOWN.24" VENT UP.34" SANITARY/WASTE DOWN.91 1/2" WASTE UP TO BACK-TO-BACK LAVATORY/BOTTLE FILLER. CONNECT 1 1/2" WASTE TO LAVATORY AND BOTTLE FILLER.106" STORM (PRIMARY SYSTEM) DOWN.116" STORM (SECONDARY SYSTEM) DOWN.126" STORM (PRIMARY SYSTEM) UP.136" STORM (SECONDARY SYSTEM) UP.141 1/2" WASTE UP TO BACK-TO-BACK SINKS/LAVATORIES. CONNECT 1 1/2" WASTE TO EACH SINK/LAVATORY.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529PATIENTTOILET527CIRCULATION504SPECIALTYEXAM/TREATMENT526PATIENTTOILET526ASTAFFTOILET525TRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FNURSEWORKAREA517EEXAM/CONSULT518EXAM/CONSULT519EXAM/CONSULT520EXAM/CONSULT522EXAM/CONSULT513CIRCULATION504BBEXAM/CONSULT514EXAM/CONSULT515EXAM/CONSULT516STAFFCIRCULATION517PROVIDEROFFICE517ANURSEWORKAREA517BEXAM/CONSULT509EXAM/CONSULT508SPECIALTYEXAM/TREATMENT506STAIRVESTIBULE504ASTAFFBREAKAREA505OFFICEMANAGER502APATIENTTOILET503REGISTRATION502PUBLICTOILET501APUBLICTOILET501BSPECIMENCOLLECTION533LABDRAW532LAB534PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535ELEVATORCONTROLROOM500EXAM/CONSULT537PATIENTTOILET536TRIAGENURSE539BEXAM/CONSULT531REGISTRATION502STAIR1ST1-3PATIENTVITALSALCOVE510STAIRST2-2STAFFTOILET505AUnoccupiedUnoccupiedSTAFFCIRCULATION517CENTRALSOILEDWORK511EXAM/CONSULT5381111ST6"6"32236"6"GUESTWAITING/CIRCULATION501ELEVB500EBELEVA500EACIRCULATION504803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:57 PMP105FIFTH FLOORPLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNDRAWING NOTES:1GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.3/16" = 1'-0"1FIFTH FLOOR PLAN - SANITARY/WASTE AND STORM236" STORM UP TO ROOF DRAIN (RD-A).6" STORM (SECONDARY SYSTEM) DOWN.6" STORM (PRIMARY SYSTEM) DOWN.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 1235ABCEF3.94" RD-A4" RD-A6" RD-A6" RD-A4" VTR4" VTR4" VTR4" VTR123803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:07:14 PMP106ROOF PLAN02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1ROOF PLANDRAWING NOTES:1PROVIDE NON-FREEZE ROOF HYDRANT WITH GALVANIZED CASING AND ADJUSTABLE FLOW WHEEL LOCK HANDLE WITH DECK FLANGE AND UNDER DECK CLAMP EQUAL TO JAY R SMITH MODEL 5906-H. PROVIDE VACUUM BREAKER. 1/8”DRAIN HOLE MUST BE PIPED AND DISCHARGED TO AN ACCEPTABLE DISCHARGE POINT. REFER TO DETAIL DRAWING(S).2CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).3TERMINATE 3/4" INDIRECT WASTE 6" ABOVE FINISHED ROOF. SLEEVE AND SEAL THROUGH EXTERIOR WALL.1. COORDINATE ALL VENT THROUGH ROOF (VTR) WITH HVACCONTRACTOR. ALL VENT TERMINATIONS ABOVE ROOF SHALL BE A MINIMUM 25'-0" (HEALTHCARE) AWAY FROM ANY HVAC OUTSIDE AIR INTAKE (ROOFTOP UNIT, LOUVER, ETC). OR AT LEAST 3 FEET ABOVE WINDOW, DOOR, OPENING, AIR INTAKE OR VENT SHAFT.GENERAL NOTES:REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.12345ABCE3.8F3.9WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1HOLDING/MAIL100CCIRCULATION105CIRCULATION105VITALSALCOVE105ASUB-WAITING105BSTAIR2ST2-1CIRCULATION105CORRIDOR122134WH5WH5WH5SPECIMENTOILET127BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125RADIOLOGY(X-RAY)119CORRIDOR143TREATMENT117EXAM113STATLAB/MED110CLEANHOLDING107SHAREDPROVIDEROFFICE104STAFFBREAK102BUILDINGMAINTENANCETOILET/SHOWER138A4"3"HHWRVCC1"HHWRVC1 1/2"1"3/4"2"3/4"1 1/2"1 1/2"3/4"HHWRC2"3/4"HHWRCHHWRCV255127777PUBLICTOILET100BMECHANICAL145CORRIDOR143WAITING/CIRCULATION123134"4"2"WH3"VVHHWRCVHHWRCVVC3/4"2"14151416668173/4"6817661796661110178661789817661166817116666817966MSS-ALAV-AWC-ALAV-AWC-ALAV-AWC-ALAV-AWC-ABF-ASINK-BSINK-ASINK-ASINK-ABF-ASINK-ALAV-AEWC-ALAV-AWC-ASINK-ASINK-ASINK-ASINK-AMSS-ASINK-ABF-ASINK-ASINK-A6SINK-A6SINK-A6SINK-ASINK-A6SINK-ALAV-AWC-AMSS-ASINK-A11BF-A17CV6SINK-A6LAV-AWC-A3/4"C C3/4"3/4"2"V3"2"2"2"3/4"3/4"2"3/4"4"3/4"2"3/4"4"2"2"1 1/2"3/4"2"1"2"3/4"3"1 1/2"2"3/4"3/4"3/4"2"2"1"3/4"2"3/4"1 1/2"1/2"1/2"6817LAV-AWC-A61818181817V 2"1719SHR-B2"1 1/2"20183/4"3/4"3/4"2"LOBBY/WAITING101RECEPTION101BLOBBY/WAITING101WAITING/CIRCULATION123803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:08:04 PMP201FIRST FLOORPLAN -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNDRAWING NOTES:1DUPLEX BOOSTER PUMP (DBP-1). REFER TO DETAIL DRAWING(S).4" REDUCED PRESSURE ZONE (RPZ) MAKE: WATTS LF957. PROVIDE 6" DRAIN. PROVIDE FUNNEL FITTING CENTERED UNDER RPZ RELIEF VALVE. RPZ RELIEF GAP SHALL BE A MINIMUM OF TWO TIMES THE RPZ DISCHARGE OPENING. REFER TO DETAIL DRAWING(S).2346" COMBINED WATER SERVICE DOWN.5SLEEVE AND SEAL.3/16" = 1'-0"1FIRST FLOOR PLAN - DOMESTIC6DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.74" VENT UP.8DROP 1 1/2" COLD TO WATER CLOSET.9DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.10DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.11DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.GENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.2WATER SERVICE ROOM 3D VIEW2" REDUCED PRESSURE ZONE (RPZ) MAKE: WATTS LF909, PROVIDE 4" DRAIN. PROVIDE FUNNEL FITTING CENTERED UNDER RPZ RELIEF VALVE. RPZ RELIEF GAP SHALL BE A MINIMUM OF TWO TIMES THE RPZ DISCHARGE OPENING. REFER TO DETAIL DRAWING(S).12DOMESTIC BLADDER TANK (DBT-1). REFER TO DETAIL DRAWING(S).134" COLD UP.14PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).15PROVIDE WALL MOUNTED EYEWASH (EW-B) AT MOP SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).16DOMESTIC WATER HEATER (HWH-1). COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS) PRIOR TO START OF WORK. REFER TO DETAIL DRAWING(S).172" VENT DOWN.18PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).19DROP 1/2" HOT AND COLD TO SHOWER.20DROP 1/2" HOT & 1 1/2" COLD AND PROVIDE SHUT-OFF VALVES IN ACCESS PANEL (BY PLUMBING CONTRACTOR). ACCESS PANEL SHALL BE LOCATED IN WALL 48" ABOVE THE FINSHED FLOOR AND OPEN TO THE CORRIDOR.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223CORRIDOR232RESPITE/LACTATION240STAFFTOILET237STAIR2ST2-1MAINLOBBY100RESPITE/MEDITATION241OFFICE238UnoccupiedUnoccupiedCIRCULATION228DENTALOFFICE230WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203CIRCULATION207NURSE214PHYSICIANOFFICE/DICTATION213LAB221MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204EDUCATION/CONFERENCE234IT/ELEC24388872VMULTIPURPOSE/ACTIVITY235STAFFBREAK242RESPITE/LACTATION239STAFFTOILET236TELMED2339HHWRCHHWRCCHHWRH H W RC HHWRCVV10111LAV-B12WC-A12SHR-A131LAV-B1LAV-B12SHR-A1316WC-B1LAV-B1SINK-C1SINK-A1LAV-A1SINK-D1LAV-A12MSS-A1SINK-A1SINK-A1SINK-A1SINK-A1SINK-A1SINK-A1SINK-B6BF-A1SINK-AWC-A1LAV-B12125EWC-A3112WC-ALAV-A6BF-A1LAV-A3WC-A121231WC-ALAV-A4CHHWRVCH1SINK-A1SINK-A1SINK-A1SINK-AHHWRC1LAV-A32"1 1/2"HHWRCV3"HHWRCV3/4"2"1"1"1/2"1/2"2"1 1/2"33/4"3/4"3/4"1 1/2"VV2"1"3/4"3/4"1"2 1/2"1"1"3/4"2"1 1/2"3/4"3"2"2"2"1 1/2"3/4"3/4"2"3/4"1 1/2"2"2"1 1/2"3/4"2"2"3/4"3/4"3/4"2"2"3/4"3/4"1 1/2"1 1/2"3/4"3/4"1"3/4"2"2"2"3/4"3/4"2"14141414141415803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:08:19 PMP202SECONDFLOOR PLANS -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1SECOND FLOOR PLAN - DOMESTICDRAWING NOTES:1DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.24" VENT UP.3DROP 1 1/2" COLD TO WATER CLOSET.4DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.5DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.6DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.GENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.74" VENT DOWN.84" VENT STACK UP AND DOWN.94" COLD RISER UP AND DOWN.10PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).11DOMESTIC WATER HEATER (HWH-1). COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS) PRIOR TO START OF WORK. REFER TO DETAIL DRAWING(S).122" VENT DOWN.13DROP 1/2" HOT AND COLD TO SHOWER.14PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).15STANDARD WATER CLOSET WITH BARIATRIC SPACING (SEE ARCHITECTURAL DRAWINGS) AND BARIATRIC GRAB BAR SUPPORTS (BY GENERAL CONTRACTOR). BARIATRIC LAVATORY SUPPORTS, COORDINATE WITH GENERAL CONTRACTOR.16DROP 1 1/2" COLD AND 2" VENT TO WATER CLOSET.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8ELEC/DATA323NURSEWORKAREA317BSTAIR2ST2-1STAIR1ST1-388827PROVIDEROFFICE339ANURSEWORK339EXAM/CONSULT328EXAM/CONSULT329PATIENTTOILET327SPECIALTYEXAM/TREATMENT326STAFFTOILET325PATIENTTOILET326ATRIAGENURSE324PROVIDEROFFICE317FEXAM/CONSULT322EXAM/CONSULT321EXAM/CONSULT320EXAM/CONSULT319EXAM/CONSULT318EXAM/CONSULT316EXAM/CONSULT315EXAM/CONSULT314EXAM/CONSULT313CENTRALCLEANWORK312CIRCULATION304EXAM/CONSULT331EXAM/CONSULT328EXAM/CONSULT327TRIAGENURSE339BPATIENTTOILET336SPECIALTYEXAM/TREATMENT/TELEMED335PATIENTTOILET335ALAB334SPECIMENCOLLECTION333LABDRAW332CENTRALSOILEDWORK311PROVIDEROFFICE317AEXAM/CONSULT306EXAM/CONSULT307EXAM/CONSULT308EXAM/CONSULT309PATIENTVITALSALCOVE310CIRCULATION304PUBLICTOILET300BPUBLICTOILET300AGUESTWAITING/CIRCULATION300REGISTRATION301OFFICEMANAGER301APATIENTTOILET302SPECIALTYEXAM/TREATMENT303STAFFBREAKAREA305STAFFTOILET305A910111SINK-A1SINK-AMSS-A1SINK-A3WC-A1LAV-A121SINK-A1LAV-A123WC-A3WC-A1LAV-A1SINK-A1SINK-A121LAV-A11WC-A3SINK-A1LAV-A33WC-AWC-ALAV-A1SINK-A1SINK-A1SINK-DSINK-A3WC-A1LAV-A1SINK-C1SINK-A31WC-ALAV-A121212123WC-A121LAV-A123WC-A5EWC-A4VHWRCHHWRCHHWRCHHWRC1SINK-A1SINK-A1SINK-A1SINK-AHHWRCV1SINK-A1SINK-A1SINK-A111SINK-AHHWRCVV1SINK-AHHWRCVHHHWRCHHWRC1SINK-A1SINK-A1SINK-AV1SINK-A1SINK-A1SINK-A1VHHWRCVV1LAV-A101 1/2"3/4"1"2"3/4"2"1/2"1/2"3"1 1/2"2"3/4"1"2"1"3/4"3/4"2"2"2"3/4"3/4"2"1 1/2"2"3/4"1/2"1 1/2"2"2"3/4"2"2"2"4"VVHWRCH131313131313131313132"3/4"3/4"3/4"1"1"3/4"1"1"3/4"2"1 1/2"3/4"3/4"3"2"2"3/4"2"2 1/2"3/4"2"2 1/2"2"2"3/4"1"1"3/4"2"1 1/2"1 1/2"1"3/4"2"3/4"1 1/2"2"2"3/4"1"1"2"1/2"1/2"3/4"3/4"1 1/2"2"2"2"1 1/2"3/4"3/4"2 1/2"1SINK-A142"133/4"2"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:08:35 PMP203THIRD FLOORPLAN -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1THIRD FLOOR PLAN - DOMESTICGENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.DRAWING NOTES:1DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.24" VENT UP.3DROP 1 1/2" COLD TO WATER CLOSET.4DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.5DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.6DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.74" VENT DOWN.84" VENT STACK UP AND DOWN.94" COLD RISER UP AND DOWN.10PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).11DOMESTIC WATER HEATER (HWH-1). COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS) PRIOR TO START OF WORK. REFER TO DETAIL DRAWING(S).122" VENT DOWN.13PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).14DROP 1/2" HOT & 1 1/2" COLD AND PROVIDE SHUT-OFF VALVES IN ACCESS PANEL (BY PLUMBING CONTRACTOR). ACCESS PANEL SHALL BE LOCATED IN WALL 48" ABOVE THE FINSHED FLOOR AND OPEN TO THE CORRIDOR.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445EVS439STAIR2ST2-1MAINLOBBY100PROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438PROCEDUREROOM440RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402WOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418AHOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS4172888V4"79101011121SINK-A1SINK-AWC-ALAV-A311SINK-A1SINK-A4MSS-A131SINK-A1SINK-A1SINK-A1SINK-A1LAV-A3WC-A4MSS-A133WC-A131LAV-A133WC-A6BF-A1LAV-A5EWC-A13WC-A31LAV-A133WC-A1LAV-A1SINK-A1311SINK-ALAV-A3WC-A1SINK-A133WC-A1SINK-A1SINK-A1SINK-A1SINK-A1LAV-A3WC-A3WC-A1LAV-A13HHWRCHHWRCHHWRCHHWRC1SINK-A1SINK-AVHWRCH134"1SINK-AV1SINK-AVVHHWRCHHWRCVHCVVV1LAV-AHHWRCHHWRCVHWRCHHHWRCVV3/4"3/4"3/4"3/4"4"2"LAV-A12"1/2"1/2"V2"1 1/2"3/4"2"2"1/2"1/2"2"2"2"2"2"2"2"1 1/2"1 1/2"3/4"3/4"2"3/4"1 1/2"1/2"2"1 1/2"3/4"2"2"2"1 1/2"3/4"3/4"3/4"1 1/2"3/4"3/4"1/2"1/2"1 1/2"2"VV2"2"HWR1414141414141414142"2"1"1"3/4"1 1/2"3/4"2"3/4"1/2"1/2"2"1"3/4"2"1"1"3/4"2"1 1/2"3/4"1/2"1/2"3/4"1 1/2"2"2"1 1/2"3/4"2"3/4"2 1/2"2 1/2"3/4"2"2"2 1/2"1 1/2"3/4"1 1/2"2"1/2"3/4"1 1/2"1"3/4"1414WOMEN'SSUB-WAIT409RESULTSALCOVE410803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:08:52 PMP204FOURTHFLOOR PLAN -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FOURTH FLOOR PLAN - DOMESTICGENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.DRAWING NOTES:1DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.24" VENT UP.3DROP 1 1/2" COLD TO WATER CLOSET.4DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.5DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.6DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.74" VENT DOWN.84" VENT STACK UP AND DOWN.94" COLD RISER UP AND DOWN.10PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).11DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO DISINFECTION UNIT (BY OTHER). 2" WASTE DOWN.12DOMESTIC WATER HEATER (HWH-1). COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS) PRIOR TO START OF WORK. REFER TO DETAIL DRAWING(S).132" VENT DOWN.14PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529PATIENTTOILET527SPECIALTYEXAM/TREATMENT526PATIENTTOILET526ASTAFFTOILET525TRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FNURSEWORKAREA517EEXAM/CONSULT518EXAM/CONSULT519EXAM/CONSULT520EXAM/CONSULT522EXAM/CONSULT513CIRCULATION504BBEXAM/CONSULT514EXAM/CONSULT515EXAM/CONSULT516STAFFCIRCULATION517PROVIDEROFFICE517ANURSEWORKAREA517BEXAM/CONSULT509EXAM/CONSULT508SPECIALTYEXAM/TREATMENT506STAIRVESTIBULE504ASTAFFBREAKAREA505OFFICEMANAGER502APATIENTTOILET503REGISTRATION502PUBLICTOILET501APUBLICTOILET501BSPECIMENCOLLECTION533LABDRAW532LAB534PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535ELEVATORCONTROLROOM500EXAM/CONSULT537PATIENTTOILET536TRIAGENURSE539BEXAM/CONSULT531REGISTRATION502STAIR1ST1-3PATIENTVITALSALCOVE510CIRCULATION504STAIRST2-2STAFFTOILET505ASTAFFCIRCULATION517REGISTRATION502CENTRALSOILEDWORK511EXAM/CONSULT53812V4"277212GUESTWAITING/CIRCULATION5018910911SINK-A1SINK-AMSS-A1SINK-A3WC-A1LAV-A1SINK-A1LAV-A113WC-A3WC-A1LAV-A1SINK-ASINK-A111LAV-A11WC-A31SINK-ALAV-AWC-AWC-A1SINK-A1SINK-D1SINK-A3WC-A1LAV-A1SINK-CWC-ALAV-A31111113WC-A1LAV-A111LAV-A3WC-A5EWC-A411HHWRCHHWRCHHWRCHHWRC1331SINK-A1SINK-A1SINK-A11V1SINK-A1SINK-AVVHHWRC1SINK-A1SINK-ALAV-AHHWRCHHWRCV1SINK-A1SINK-A1SINK-A1SINK-A1SINK-AHHWRCV1SINK-A3/4"2"3/4"11111SINK-A1SINK-A1SINK-AV1116HHWRCVHCVHHWRC1/2"1/2"HCHCVHCVHC1/2"1/2"2"2"1/2"1/2"2"1 1/2"1 1/2"2"2"2"1/2"V2"1 1/2"2"HHWRCHCV1/2"2"1/2"2"3/4"HWH-12"3/4"1/2"2"3/4"1 1/2"1/2"1 1/2"2"1/2"2"1/2"2"3/4"HWR3/4"3/4"1/2"BF-A1SINK-AHWRV132"13131313131313131313V2"4"3/4"3/4"3/4"2"2"3/4"1 1/2"4"4"2"2"3/4"3/4"3/4"1 1/2"2"1 1/2"1"3/4"2"1/2"1/2"3"1"1"3/4"3/4"1"1"2"2"1/2"1/2"3/4"1/2"2"3/4"1/2"3/4"1/2"2"1 1/2"1"3/4"2"3/4"1 1/2"3/4"1/2"1 1/2"3"3/4"3/4"14133/4"C15REGISTRATION502REGISTRATION502803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:09:11 PMP205FIFTH FLOORPLAN -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FIFTH FLOOR PLAN - DOMESTICGENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.DRAWING NOTES:1DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.24" VENT DOWN.3DROP 1 1/2" COLD TO WATER CLOSET.4DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.5DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.6DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.74" VENT DOWN, 4" VENT THROUGH ROOF.84" COLD DOWN.9PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).10DOMESTIC WATER HEATER (HWH-1). REFER TO DETAIL DRAWING(S).112" VENT DOWN.124" VENT THROUGH ROOF.13PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).14DROP 1/2" HOT & 1 1/2" COLD AND PROVIDE SHUT-OFF VALVES IN ACCESS PANEL (BY PLUMBING CONTRACTOR). ACCESS PANEL SHALL BE LOCATED IN WALL 48" ABOVE THE FINSHED FLOOR AND OPEN TO THE CORRIDOR.153/4" COLD UP TO NON-FREEZE ROOF HYDRANT WITH GALVANIZED CASING AND ADJUSTABLE FLOW WHEEL LOCK HANDLE WITH DECK FLANGE AND UNDER DECK CLAMP EQUAL TO JAY R SMITH MODEL 5906-H. PROVIDE VACUUM BREAKER. 1/8”DRAIN HOLE MUST BE PIPED AND DISCHARGED TO AN ACCPETABLE DISHCARGE POINT.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.12345ABCE3.8F3.9WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEVS109EXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1HOLDING/MAIL100CCIRCULATION105CIRCULATION105VITALSALCOVE105ASUB-WAITING105BSTAIR2ST2-1CIRCULATION105CORRIDOR12222IW31111111111111111SPECIMENTOILET127BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125RADIOLOGY(X-RAY)119CORRIDOR143TREATMENT117EXAM113STATLAB/MED110CLEANHOLDING107SHAREDPROVIDEROFFICE104STAFFBREAK102BUILDINGMAINTENANCETOILET/SHOWER138A1VISITORTOILET101ARECEPTION101BLOBBY/WAITING1011112"2"2"1111IWIWIW3/4"3/4"3/4"3/4"IW3/4"3/4"44IW3/4"3/4"443/4"3/4"4IW3/4"IW3/4"3/4"3/4"5IWIW3/4"3/4"3/4"4IW43/4"IW3/4"3/4"4IW3/4"IW 3/4"3/4"41IWIWIW3/4"3/4"3/4"443/4"4IW3/4"3/4"5PUBLICTOILET100BMECHANICAL145CORRIDOR1433/4"13/4"42"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:09:24 PMP301FIRST FLOORPLAN -INDIRECTWASTE02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIRST FLOOR PLAN - INDIRECT WASTENDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2SUMP PUMP IN ELEVATOR SHAFT. REFER TO DETAIL DRAWING(S). PROVIDE 2" INDIRECT WASTE AS SHOWN.3TERMINATE 2" INDIRECT WASTE 6" ABOVE FLOOD RIM OF MOP SERVICE SINK.DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).45TERMINATE 3/4" INDIRECT WASTE 6" ABOVE FLOOD RIM OF MOP SERVICE SINK.GENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223STAIRST2-2CORRIDOR23211111111111111111111RESPITE/LACTATION240STAFFTOILET237STAIR2ST2-1MAINLOBBY100RESPITE/MEDITATION241OFFICE238UnoccupiedUnoccupiedCIRCULATION228DENTALOFFICE230WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203CIRCULATION207NURSE214PHYSICIANOFFICE/DICTATION213LAB221MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204EDUCATION/CONFERENCE234IT/ELEC2431111IWIW3/4"3/4"3/4"3/4"3/4"3/4"223/4"2IWIW3/4"3/4"IWIW23/4"3/4"23/4"2IW 3/4"3/4"2IW3/4"IW3/4"3/4"3/4"IW3/4"IW3/4"IW3/4"2IW3/4"IW3/4"3/4"3/4"3/4"2IWIWIW3/4"3/4"3/4"2IW23/4"2TELMED233STAFFBREAK242STAFFBREAK242RESPITE/LACTATION239STAFFTOILET236MULTIPURPOSE/ACTIVITY235WALKINGTRACK200STAIR1ST1-2803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:09:35 PMP302SECONDFLOOR PLAN -INDIRECTWASTE02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1SECOND FLOOR PLAN - INDIRECT WASTEDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).NGENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8ELEC/DATA323NURSEWORKAREA317BSTAIR2ST2-1STAIR1ST1-31111111EXAM/CONSULT315EXAM/CONSULT314EXAM/CONSULT313CENTRALCLEANWORK312CENTRALSOILEDWORK311EXAM/CONSULT309EXAM/CONSULT308EXAM/CONSULT307EXAM/CONSULT306SPECIALTYEXAM/TREATMENT303PATIENTTOILET302REGISTRATION301OFFICEMANAGER301ASTAFFBREAKAREA305CIRCULATION304CIRCULATION304PUBLICTOILET300BPUBLICTOILET300AGUESTWAITING/CIRCULATION300REGISTRATION301CIRCULATION304CIRCULATION304EXAM/CONSULT322EXAM/CONSULT321EXAM/CONSULT320EXAM/CONSULT319EXAM/CONSULT318PROVIDEROFFICE317ATRIAGENURSE324PATIENTTOILET326ASTAFFTOILET325SPECIALTYEXAM/TREATMENT326PATIENTTOILET327CIRCULATION304EXAM/CONSULT329EXAM/CONSULT331LABDRAW332SPECIMENCOLLECTION333EXAM/CONSULT328NURSEWORK339EXAM/CONSULT328LAB334PATIENTTOILET335ASPECIALTYEXAM/TREATMENT/TELEMED335PATIENTTOILET336TRIAGENURSE339BEXAM/CONSULT327EVS330PROVIDEROFFICE339A11111111111111111111222111IW3/4"3/4"3/4"3/4"IWIW3/4"3/4"3/4"3/4"3/4"223/4"3/4"IW2IW3/4"2IW3/4"213/4"IW23/4"3/4"IW23/4"123/4"IW3/4"3/4"IW3/4"IW2IW3/4"223/4"23/4"IW3/4"3/4"3/4"3/4"3/4"3/4"IWIW22IW3/4"3/4"IW23/4"3/4"IWIW3/4"3/4"EXAM/CONSULT316STAFFCIRCULATION317STAFFTOILET305AREGISTRATION3013/4"13/4"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:09:47 PMP303THIRD FLOORPLAN -INDIRECTWASTE02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1THIRD FLOOR PLAN - INDIRECT WASTENDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).GENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445EVS439STAIR1ST1-3STAIR2ST2-111111111111111111111121PROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438PROCEDUREROOM440RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402WOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418ACIRCULATION412HOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS417111111111IW3/4"3/4"3/4"3/4"3/4"2IW3/4"2IW3/4"3/4"3/4"3/4"3/4"23/4"3/4"IW3/4"2IW3/4"3/4"IW3/4"2IWIW3/4"3/4"3/4"3/4"IW23/4"3/4"3/4"IW2IW3/4"3/4"3/4"3/4"12IWIW3/4"3/4"3/4"2IW3/4"3/4"2IW3/4"3/4"3/4"2IW3/4"3/4"IW3/4"13/4"2IWIWIW3/4"3/4"3/4"3/4"23/4"IW3/4"3/4"ELEVATORLOBBY&PUBLICCORRIDOR400WOMEN'SSUB-WAIT409RESULTSALCOVE410803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:00 PMP304FOURTHFLOOR PLAN -INDIRECTWASTE02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FOURTH FLOOR PLAN - INDIRECT WASTENDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).GENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529PATIENTTOILET527CIRCULATION504SPECIALTYEXAM/TREATMENT526PATIENTTOILET526ASTAFFTOILET525TRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FNURSEWORKAREA517EEXAM/CONSULT518EXAM/CONSULT519EXAM/CONSULT520EXAM/CONSULT522EXAM/CONSULT513CIRCULATION504BBEXAM/CONSULT514EXAM/CONSULT515EXAM/CONSULT516STAFFCIRCULATION517PROVIDEROFFICE517ANURSEWORKAREA517BEXAM/CONSULT509EXAM/CONSULT508SPECIALTYEXAM/TREATMENT506STAIRVESTIBULE504ASTAFFBREAKAREA505OFFICEMANAGER502APATIENTTOILET503PUBLICTOILET501APUBLICTOILET501BSPECIMENCOLLECTION533LABDRAW532LAB534PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535ELEVATORCONTROLROOM500EXAM/CONSULT537PATIENTTOILET536TRIAGENURSE539BEXAM/CONSULT531REGISTRATION502STAIR1ST1-3PATIENTVITALSALCOVE510STAIRST2-2STAFFTOILET505AUnoccupiedUnoccupiedSTAFFCIRCULATION517CENTRALSOILEDWORK511EXAM/CONSULT5381111111111111111111111111111111IW23/4"3/4"3/4"IWIW2123/4"IW23/4"23/4"IW3/4"213/4"IW23/4"3/4"IW3/4"3/4"3/4"3/4"3/4"23/4"IW3/4"2IW3/4"2IW3/4"IW3/4"2IW3/4"3/4"3/4"23/4"223/4"2IW3/4"23/4"3/4"1213/4"3/4"3/4"3/4"IWIWIW3/4"IW3/4"3/4"223/4"IWIWIW3/4"3/4"3/4"GUESTWAITING/CIRCULATION501CENTRALCLEANWORK512CIRCULATION504ELEVA500EAELEVB500EBSTAIR1ST1-5IW3/4"IW13/4"3/4"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:13 PMP305FIFTH FLOORPLAN -INDIRECTWASTE02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIFTH FLOOR PLAN - INDIRECT WASTENDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).GENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 EXHIBIT "II" - EQUIPMENT INSULATION MATERIALS(NOTES ARE AT END OF EXHIBIT)SERVICEINSULATION MATERIALTHICKNESSREMARKSDOMESTIC HOT WATER TANKSCALCIUM SILICATEOR6 LB. FIBERGLASS SUITABLE FOR 450°SERVICE1-1/2" SEGMENTEDBLOCKS OR MOLDED SECTIONSSECURE BLOCKS WITH GALVANIZED STEEL BANDS, 12" O.C. SECURE FIBERGLASS WITH PINS, STUDS, OR CLIPS, THENAPPLY 2" GALVANIZED HEXAGON MESH WIRE. COVER WITH 1/4" LAYER INSULATING CEMENT. RECOVER - SEE NOTE 1DOMESTIC WATER PUMPSFLEXIBLE SHEETS1/2"INSTALL ON "BOX" FRAMING PER MANUFACTURER'S CONSTRUCTIONSPECIFICATIONS. ARRANGE FOR EASY REMOVAL AND REPLACEMENT. COAT WITH WHITE FINISHWHERE REQUIRED, PROVIDE WELDED STUDS, CLIPS OR ANGLES AS ANCHORS FOR BANDS, WIRES AND MESH.EXHIBIT "I" - PIPE INSULATION MATERIALS(NOTES ARE AT END OF EXHIBIT)SERVICEINSULATION MATERIALTHICKNESSREMARKSDOMESTIC COLD WATERGLASS FIBER ORFLEXIBLE1-1/2" AND LARGER.....1"1-1/4" AND SMALLER.....1/2"SEE NOTE 2DOMESTIC HOTAND CIRCULATION WATER(UP TO 140°)GLASS FIBER ORFLEXIBLE1-1/2" TO 8".....1-1/2"1-1/4" AND SMALLER.....1"RUNOUTS.....1"DOMESTIC HOTAND CIRCULATION WATER(OVER 140°)GLASS FIBER1-1/2" TO 8".....2"1-1/4" AND SMALLER.....1-1/2"RUNOUTS.....1-1/2"AC UNITS DRAINSAND OVERFLOWS(INDIRECT WASTE)ALL SIZES.....1/2"ROOF CONDUCTOR LINESGLASS FIBERALL SIZES.....1"INSULATE BODY OF DRAIN AND CONDUCTOR PIPING, HORIZONTAL [AND VERTICAL] DOWN TOCONNECTION BELOW GROUND FLOOR SLAB OR IN CRAWL SPACENOTES FOR EXHIBIT INOTE 1:EXPOSED INSULATION SHALL BE COVERED WITH A PVC JACKET.FLEXIBLE ALLOWED IN 1/2 IN. THICKNESS ONLY.NOTE 2:NOTES FOR EXHIBIT IINOTE 1:HANGER SPACINGPIPING MATERIALMAXIMUM HORIZONTALSPACING (FEET)MAXIMUM VERTICALSPACING (FEET)ACRYLONITRILE BUTADIENE STYRENE(ABS) PIPING410ALUMINUM TUBING1015BRASS PIPE1010CAST-IRON PIPE515CHLORINATED POLYVINYL CHLORIDE(CPVC) PIPE AND TUBING,1 INCH AND LARGER310CHLORINATED POLYVINYL CHLORIDE(CPVC) PIPE AND TUBING, 1 1/4" INCHES AND LARGER410COPPER OR COPPER-ALLOY PIPE 12 10COPPER OR COPPER-ALLOY TUBING,1 1/4 -INCH DIAMETER ANDSMALLER610COPPER OR COPPER-ALLOY TUBING 1 1/2 -INCH DIAMETER ANDLARGER10 10CROSS-LINKED POLYETHYLENE (PEX)PIPE2.67(32 INCHES)10CROSS-LINKED POLYETHYLENE/ALUMINUM/CROSS-LINKEDPOLYETHYLENE (PEX-AL-PEX) PIPE2.67(32 INCHES)4LEAD PIPECONTINUOUS4POLYETHYLENE/ALUMINUM/POLYETHYLENE (PE-AL-PE) PIPE2.67(32 INCHES)4POLYETHYLENE OF RAISEDTEMPERATURE (PE-RT) PIPE2.67(32 INCHES)10POLYPROPYLENE (PP) PIPE ORTUBING 1 INCH AND SMALLER2.67(32 INCHES)10POLYPROPYLENE (PP) PIPE ORTUBING, 1 1/4 INCHES AND LARGER410POLYVINYL CHLORIDE (PVC) PIPE410STAINLESS STEEL DRAINAGE SYSTEMS 10 10STEEL PIPE1215MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPESFIXTUREMINIMUM PIPE SIZE (INCH)BATHTUBS (60"x32" AND SMALLER)1/2BATHTUBS (LARGER THAN 60"x32") 1/2BIDET3/8COMBINATION SINK AND TRAY1/2DISHWASHER, DOMESTIC1/2DRINKING FOUNTAIN3/8HOSE BIBBS1/2KITCHEN SINK1/2LAUNDRY, 1, 2, OR 3 COMPARTMENTS1/2LAVATORY3/8SHOWER, SINGLE HEAD1/2SINKS, FLUSHING RIM3/4SINKS, SERVICE1/2URINAL, FLUSH TANK1/2URINAL, FLUSHOMETER VALVE3/4WALL HYDRANT1/2WATER CLOSET, FLUSH TANK3/8WATER CLOSET, FLUSHOMETER TANK3/8WATER CLOSET, FLUSHOMETER VALVE1WATER CLOSET, ONE PIECE1/2MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES ANDFIXTURE FITTINGSPLUMBING FIXTURE OR FIXTURE FITTINGMAXIMUM FLOW RATE ORQUANTITYLAVATORY, PUBLIC 0.5 GPM AT 60 PSISHOWER HEAD 1.8 GPM AT 80 PSISINK FAUCET 1.5 GPM AT 60 PSIURINAL0.5 GALLON PER FLUSHINGCYCLEWATER CLOSET1.28 GALLONS PER FLUSHINGCYCLEa. THE MAXIMUM HORIZONTAL SPACING OF CAST-IRON PIPE HANGERS SHALLBE INCREASED TO 10 FEET WHERE 10-FOOT LENGTHS OF PIPE AREINSTALLED.b. FOR SIZES 2 INCHES AND SMALLER, A GUIDE SHALL BE INSTALLED MIDWAYBETWEEN REQUIRED VERTICAL SUPPORTS. SUCH GUIDES SHALL PREVENTPIPE MOVEMENT IN A DIRECTION PERPENDICULAR TO THE AXIS OF THE PIPE.a.b.CONSUMPTION TOLERANCES SHALL BE DETERMINED FROM REFERENCED STANDARDS.a. WHERE THE DEVELOPED LENGTH OF THE DISTRIBUTION LINE IS 50FEET OR LESS, AND THE AVAILABLE PRESSURE AT THE METER IS 35PSI OR GREATER, THE MINIMUM SIZE OF AN INDIVIDUAL DISTRIBUTIONLINE SUPPLIED FROM A MANIFOLD AND INSTALLED AS PART OF APARALLEL WATER DISTRIBUTION SYSTEM SHALL BE ONE NOMINAL TUBESIZE SMALLER THAN THE SIZES INDICATED.CONDENSATE DRAIN SIZINGEQUIPMENT CAPACITYMINIMUM CONDENSATE PIPEDIAMETER (INCH)UP TO 20 TONS OF REFRIGERATION 3/4 INCHOVER 20 TONS TO 40 TONS OF REFRIGERATION 1 INCHOVER 40 TONS TO 90 TONS OF REFRIGERATION1 1/4 INCHOVER 90 TONS TO 125 TONS OF REFRIGERATION 1 1/2 INCHOVER 125 TONS TO 250 TONS OF REFRIGERATION 2 INCHSIZE OF PIPE IDENTIFICATIONPIPE DIAMETER(INCHES)LENGTHBACKGROUND COLORFIELD (INCHES)SIZE OF LETTERS(INCHES)3/4 TO 1 1/480.51 1/2 TO 280.752 1/2 TO 6 12 1.258 TO 10 24 2.5OVER 10 32 3.5WHERE USED, IDENTIFICATION TAPE SHALL BE AT LEAST 3 INCHES (76MM) WIDEAND HAVE WHITE OR BLACK LETTERING ON A PURPLE FIELD STATING "CAUTION:NONPOTABLE WATER - DO NOT DRINK" IDENTIFICATION TAPE SHALL BEINSTALLED ON TOP OF NONPOTABLE RAINWATER DISTRIBUTION PIPES, FASTENEDAT LEAST EVERY 10 FEET (3048 MM) TO EACH PIPE LENGTH AND RUNCONTINUOUSLY THE ENTIRE LENGTH OF THE PIPE.SLOPE OF HORIZONTAL DRAINAGE PIPESIZE(INCHES)MINIMUM SLOPE(INCH PER FOOT)2 1/2 OR LESS 1/43 TO 61/88 OR LARGER1/16MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENTSIZE OF TRAP(INCHES)SLOPE(INCHES PER FOOT)DISTANCE FROM TRAP(FEET)1 1/41/451 1/21/4621/4831/81241/816COMMON VENT SIZESPIPE SIZE(INCHES)MAXIMUM DISCHARGE FROM UPPER FIXTURE DRAIN(DFU)1 1/21242 1/2 TO 36WASTE STACK VENT SIZESTACK SIZE(INCHES)MAXIMUM NUMBER OF DRAINAGE FIXTURE UNITS(DFU)TOTAL DISCHARGE INTOONE BRANCH INTERVALTOTAL DISCHARGE FORSTACK1 1/2122242 1/2NO LIMIT83NO LIMIT244NO LIMIT505NO LIMIT756NO LIMIT100STORM DRAIN SIZINGPIPE SIZE(INCHES)CAPACITY (GPM)VERTICALDRAINSLOPE OF HORIZONTAL DRAIN1/16 INCH PER FOOT 1/8 INCH PER FOOT 1/4 INCH PER FOOT 1/2 INCH PER FOOT234152231443873955791114180811151632315311117165234331653824334448768981,1175057141,0101,42910 2,0509271,3111,8552,62312 3,2721,4802,0932,9604,18715 5,5432,5083, 5465,0167,093THE FLUSH VOLUME FOR A DUAL-FLUSH WATER CLOSET IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSHHOT WATER PIPING VOLUME AND MAXIMUM PIPING LENGTHSNOMINAL PIPE SIZE (INCHES)MAXIMUM PIPING LENGTH (FEET)VOLUME (LIQUID OUNCES PER FOOT LENGTH)PUBLIC LAVATORY FAUCETSOTHER FIXTURES AND APPLIANCES1/4 0.33 6 505/16 0.5 4 503/8 0.75 3 501/2 1.52435/821323/430.5217/840.516150.5131 1/480.581 1/2110.562 OR LARGER180.54NOTE:FIXTURE/EQUIPMENT SIZES NOTED ABOVE SHALL BE USED UNLESS OTHERWISE NOTED.FIXTURE CONNECTION SCHEDULEITEMHOT(H)COLD(C)SANITARY/WASTE(W)VENT(V)COMMENTSWATER CLOSET (VALVE)WATER CLOSET (TANK)URINALLAVATORYMOP SERVICE SINKSINKCLINICAL SERVICE SINKSHOWERTUBELECTRIC WATER COOLERHOSE BIBBWALL HYDRANTFLOOR DRAINWASHING MACHINE FITTING1 1/2"1/2"3/4"1/2"3/4"1/2" 1/2"1 1/2"1/2"1/2"1/2"3/4"3/4"1/2"1/2"3/4"1/2"1/2"4"4"2"1 1/2"3"1 1/2"3"2"2"3"1 1/2"2"2"2"2"1 1/2"1 1/2"2"2"2"2"PROVIDE CHECK VALVES ON SUPPLY LINES1 1/2"2"2"SANITARY/WASTE GLASS FIBER ALL SIZES.....1" INSULATE IN PARKING GARAGESGLASS FIBER ORFLEXIBLESEE NOTE 2EXHIBIT "A" - PIPING MATERIALS (PLUMBING)(NOTES AT END OF EXHIBIT "A")SERVICEPIPE MATERIALFITTINGSCONNECTIONSWATER SERVICEFIRE SERVICEDUCTILE IRONWITH CEMENT LININGBELL & SPIGOTMECHANICAL OR GROOVED RUBBER GASKETDOMESTIC WATER INTERIOR:LOW TEMP HOT (<120°), COLD ANDCIRCULATION (<120°) 3" AND SMALLERTYPE L COPPERWROUGHT COPPER (USE LONGRADIUS ELBOWS ONLY FOR HWRLINE; SHORT RADIUS ELBOW ARENOT ACCEPTABLE)NO-LEAD SOLDER, PRO-PRESSDOMESTIC WATER INTERIOR:HIGH TEMP HOT (>140°), COLD, ANDCIRCULATION (>140°) 3" AND SMALLERTYPE L COPPERWROUGHT COPPER (USE LONGRADIUS ELBOWS ONLY FOR HWRLINE; SHORT RADIUS ELBOW ARENOT ACCEPTABLE)NO-LEAD SOLDER, PRO-PRESSDOMESTIC WATER INTERIOR:HOT, COLD, AND CIRCULATION 4" AND LARGERSCHEDULE 40,GALVANIZED STEEL,TYPE L COPPERGALVANIZED STEEL,WROUGHT COPPERTHREADED, NO-LEAD SOLDERSANITARY, SANITARY VENT,AND STORM(BURIED)PVC PVC SOLVENT WELDEDSANITARY, AND SANITARY VENT, AND STORM (NOT BURIED)SERVICE WEIGHT ORHUBLESS CAST IRON SOIL PIPE OR TYPE DWV COPPER ORSCHEDULE 40, GALVANIZED STEEL (GROOVED)CAST IRON HUBAND SPIGOT, NO-HUBORWROUGHT COPPER;GALVANIZED DRAINAGELEAD AND OAKUM, NO-HUB NEOPRENE GASKET ANDSTAINLESS STEEL CLAMP ASSEMBLY OR NO-LEAD SOLDER; THREADED; GROOVED MECHANICALINDIRECTWASTETYPE DWV COPPER WROUGHT COPPER NO-LEAD SOLDERSUMP PUMP DISCHARGE(NON-SEWAGE MATERIAL)TYPE DWVCOPPERWROUGHT COPPERNO-LEAD SOLDERNOTES FOR EXHIBIT ANOTE 1: ALL EXPOSED PIPING WITHIN FINISHED AREAS SHALL BE PAINTED WITH A PRIMER COAT AND TWO FINISH COATS. COLOR PER ARCHITECT/OWNER.NOTE 2: USE LONG RADIUS ELBOWS ONLY FOR HOT WATER RETURN LINES. SHORT RADIUS ELBOWS ARE NOT ACCEPTABLE FOR HOT WATER RETURN LINES.NOTE 3: ON BURIED COATED STEEL PIPE, TAPE ALL JOINTS WITH SCOTCHWRAP #50, 2IN, WIDE, 50% OVERLAP. PROVIDE CATHODIC PROTECTION SYSTEM.NOTE 4: PVC, CPVC AND PEX PIPING SHALL NOT BE USED IN THE FOLLOWING LOCATIONS: MECHANICAL/BOILER ROOMS, COMMERCIAL KITCHENS, COMMERCIAL LAUNDRY ROOMS, CEILINGSPACES THAT ARE UTILIZED AS MECHANICAL SYSTEM RETURN AIR PLENUMS, ROOMS/CLOSETS WITH GAS FIRED EQUIPMENT.NOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE PLUMBING SCOPE. PIPING MATERIAL, WATER QUALITY, HOT WATER HEATER EFFICIENCY, LEGIONELLA CONTROL, WATER SENSE FIXTURES, FIXTURE WATER CONSUMPTION, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 220800 AND 019113 FOR COMMISSIONING REQUIREMENTS.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:16 PMP401SCHEDULES02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 FIXTURE SCHEDULEWATER CLOSETSMARKFIXTUREMAKEMODELMOUNTINGTYPEMAXIMUM GPFADAACCESSORIESWC-AELONGATEDWATER CLOSET3043.001FLOORFLUSH VALVEYES2. CHURCH MODEL 9500SSC SEAT (LESS COVER)LAVATORIESMARKFIXTUREMAKEMODELMOUNTINGNOMINAL DIMENSIONS(LxWxD)BOWL SIZE (LxWxD) ADAACCESSORIESLAV-AVITREOUSCHINA LAVATORYKOHLERK-2084WALL20"x18"18"x13"x4-1/8" YES2. JAY R. SMITH SERIES 0700 CARRIER3. MOUNT FIXTURE AT ADA HEIGHT AND PROVIDE BROCAR 500R INSULATION COVERINGSSINKSMARKFIXTUREMAKEMODELMOUNTINGNOMINAL DIMENSIONS(LxW)BOWL SIZE (LxWxD)ADA ACCESSORIESSINK-ASINGLE BOWLACRYLIC-POLYESTER (EXAM ROOMS)CORIAN ELEMENTS8254LAY-INCOUNTERTOP19-1/2x14-3/818x12-3/4x5 YES1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPMSINK-BSINGLE BOWLSTAINLESSSTEEL SINKELKAY"LUSTERTONE"LRAD-1918LAY-INCOUNTERTOP19x1816x11-1/2x6-1/2 YESSINK-CDOUBLE BOWLSTAINLESSSTEEL SINKELKAY"DAYTON"D2251925x19x6-5/1610x14x6-1/8MSS-AMOP SERVICESINKFIATMSB-2424FLOOR24x2424x24x10NO1. CHICAGO MODEL 897-CCP WALL MOUNTED FAUCET & VACUUM BREAKER & PAIL HOOK2. PROVIDE FIAT MODEL 889-CC MOP BRACKET3. PROVIDE FIAT MODEL E-77-AA RIGID VINYL BUMPER GUARDSELECTRIC WATER COOLERS & BOTTLE FILLERSMARK FIXTUREMAKEMODELSINGLE ORDOUBLEWALL ORFLOORRECESSED ORSURFACEHEIGHTWIDTHDEPTHGPH @80°FADA ACCESSORIES1. VOLTS - 1152. Hp - 1/53. Hz - 604. SINGLE PHASESHOWERS AND TUBSMARK FIXTURE MAKEMODELMATERIAL WIDTH DEPTH HEIGHT ADAACCESSORIESSHR-ASHOWERCOMFORT DESIGNSST 3838 TR RRF .75GEL COAT 38-1/2"37-3/16"79" YES2. AMERICAN STANDARD RU101SS FLASH ROUGH VALVE 1. AMERICAN STANDARD HAND HELD SHOWER SYSTEM MODEL TU662SG.213, ADA 1.5 GPMPUMPSMARKTYPEQTY. LOCATION SERVICE FLUIDGPM HEADHP VOLTS PHASE MAKE MODELREMARKSESP-1ELEVATOR SUMPPUMP(SUBMERSIBLE)2ELEVATORINDIRECT WASTESYSTEMWATER50 25 FT 3/41151ELV290WATER HEATERSMARK TYPEQTY. LOCATIONGAL. WIDTH HEIGHTVENTVOLT WATT H&C MAKE MODELREMARKS---2083/4"EXPANSION TANKSMARK SERVICE LOCATION TYPETANK VOLUME CONNECTION SIZE MAX PRESS MEAN OPERATING TEMP. CHARGEMAKE MODEL ASMEGALLON INCHES PSIDEG. FPSIMIXING VALVESMARK LOCATIONCvMIN. FLOW COLD EWT HOT EWT LWT MAX PDMAKE MODEL REMARKSGPM DEG. F DEG. F DEG. F@ HOT WATER HEATERSPOWERS LFLM492-23. PROVIDE 2" SHOWER DRAIN, SEAT, REINFORCED GRAB BARSMV-11. PROVIDE TWO (2) MIXING VALVES PIPED IN PARALLEL (PER FLOOR) AT EACH HOT WATER HEATER FOR BETTER FLOW RATE AND LOW FLOW CONTROL4500HPA082KDLOCHINVAR8027" 69"MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPESDIAMETER OFVENT PIPE(INCHES)INDIVIDUAL VENT AIRFLOW RATE (CUBIC FEET PER MINUTE)MAXIMUM DEVELOPED LENGTH OF VENT (FEET)12345678910 11 12 13 14 15 16 17 18 19 201/2 952513854321111111111113/4 100 88 47 30 20 15 1097654333222211--10094654837292420171412119877661 1/4-------1008773625346403632292623211 1/2-----------10096847565605449452-------------------100HWRP-1HOT WATERRECIRCULATIONMECHANICALROOMDOMESTIC WATERSYSTEMWATER 15 31 FT 1/6 1151MAGNA 1 32-100 FNEFFENERGY STARAMERICAN STANDARD"MADERA"1.28EWC-A8YES19"ELECTRICWATERCOOLERELKAY WALLSURFACELZSTL8WSVR DOUBLEH- 38-3/8"L- 32-7/8"35-3/4"1. SLOAN "SLOAN-OPTIMA" MODEL 111-YO-1.28 ES-S TMO (SENSOR, HARD WIRE), ADA , 1.28 GPFDBP-1DOMESTIC BOOSTER PUMP(DUPLEX SYSTEM)1MECHANICALROOMDOMESTIC WATERSYSTEMWATER 226 35 PSI7-1/2 2083GRUNDFOSMPC-E 2CRE32-2-11. PROVIDE GRUNDFOS CU352 ENERGY SAVING PUMP MANAGEMENT UNITHWH-1HEAT PUMP ELECTRICWATER HEATER5 REFER TO FLOOR PLANS (1 PER FLOOR)1. PROVIDE HEAT TRAPS AS REQUIRED BY CODE2. PROVIDE INLET AND OUTLET OUTDOOR AIR KIT AND DUCT ADAPTORS3. FINAL ELECTRICAL CONNECTIONS BY ELECTRICAL CONTRACTORDET-1 DOMESTICMECHANICALROOMVERTICAL 4.5WATTS DET-12-M1FIELD CHARGE TO MATCH SYSTEM PRESSURE140.01503/4"ASMENOREMARKSNO LIBERTY1. SUBMERSIBLE SUMP PUMP WITH OIL-TECTOR CONTROLGRUNDFOSEYEWASHESPOWERS ES150MV-24040110851401101. VOLTS - 1152. Hp - 1/53. Hz - 604. SINGLE PHASEBF-A8YES5-3/8"BOTTLE FILLERELKAY WALL SURFACELZWSSM SINGLEH- 25-7/16"L- 17-15/16"8-3/16"YES1. ELKAY ALLURE SATIN STAINLESS STEEL MODEL LK7921SSS DECK MOUNTED FAUCET, 1.5 GPM, ADA5 1. PROVIDE WHERE NOTED ON THE PLANS - HYDROGUARD XP SERIES EMERGENCY TEMPERING VALVE WITH COLD WATER BYPASS1. ULTRA HIGH EFFICIENCY PUMP WITH AQUASTAT AND PUMP TIMERLAV-B INTEGRAL INTEGRAL------YES2. PROVIDE BROCAR 500R INSULATION COVERINGS1. ELKAY ALLURE SATIN STAINLESS STEEL MODEL LK7921SSS DECK MOUNTED FAUCET, 1.5 GPM, ADA.BY GENERAL CONTRACTORBY GENERAL CONTRACTORSINK-ADEDUCT ALTERNATESINGLE BOWLSTAINLESSSTEEL SINK (EXAM ROOMS)ELKAY"LUSTERTONE"LRAD-221955LAY-INCOUNTERTOP22x19-1/2 18x14x5-3/8 YES1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPM1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPM1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPMLAY-INCOUNTERTOP2. PROVIDE 44 GALLON BLADDER TANK (DBT-1) EQUAL TO THRUSH MODEL WHV 165 0.515 PSI15 PSI13 GPM6.2 GPMSINK-DDOUBLE BOWLSTAINLESSSTEEL SINKDLR291810 29x18 12x12x10NO1. ELKAY ALLURE SATIN STAINLESS STEEL MODEL LK7921SSS DECK MOUNTED FAUCET, 1.5 GPM, ADALAY-INCOUNTERTOPELKAY"LUSTERTONE"SHR-B SHOWER --- --- --- YES2. AMERICAN STANDARD RU101SS FLASH ROUGH VALVE 1. AMERICAN STANDARD HAND HELD SHOWER SYSTEM MODEL TU662SG.213, ADA 1.5 GPM3. PROVIDE 2" SHOWER DRAIN, REINFORCED GRAB BARSTILE BY OTHERTILE BY OTHERTILE BY OTHER4. PROVIDE MUSTEE MODEL 99 DURAPAN UNDER WATER HEATERWC-BELONGATEDWATER CLOSETAMERICAN STANDARD"AFWALL"2257.101.020 WALL FLUSH VALVE 1.3 YES1. SLOAN "SLOAN-OPTIMA" MODEL 111-YO-1.28 ES-S TMO (SENSOR, HARD WIRE), ADA , 1.28 GPF2. CHURCH MODEL 9500SSC SEAT (LESS COVER)3. JAY R. SMITH SERIES 0200-0500 CARRIERNOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE PLUMBING SCOPE. PIPING MATERIAL, WATER QUALITY, HOT WATER HEATER EFFICIENCY, LEGIONELLA CONTROL, WATER SENSE FIXTURES, FIXTURE WATER CONSUMPTION, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 220800 AND 019113 FOR COMMISSIONING REQUIREMENTS.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:20 PMP402SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 NOTES:PVC PIPING SHALL NOT BE USED WITHIN CEILING SPACES THAT ARE UTILIZED AS MECHANICAL SYSTEM RETURN AIR PLENUMS.3.REFER TO SPECIFICATIONS FOR PIPING AND INSULATION REQUIREMENTS.PLUMBING CONTRACTOR SHALL CONNECT CONDENSATE PIPING TO EACHHVAC UNIT AND PROVIDE HARD PIPED TRAP, FITTINGS AND UNION, AS WELLAS ALL CONDENSATE PIPING.2.1.SLOPE AT 1/4" PER FOOTCONDENSATE DRAIN NIPPLE- FIELD VERIFY SIZE ANDCOORDINATE EXACT LOCATIONWITH HVAC CONTRACTORCONDENSATE WASTE ROUTE ASSHOWN ON PLANSFLEXIBLE TUBING FURNISHED WITH HVAC UNIT.CLAMP ONE END TO UNIT NIPPLE, CLAMP THEOTHER END TO CONDENSATE WASTE PIPING. PROVIDE CLAMPS.DRAIN PAN1" GREATER THAN HALF OFFAN TOTAL STATIC PRESSUREFAN STATICPRESSURE2" MIN.CONDENSATE DRAINS FOR TERMINAL HVAC UNITS SHALL BE PROVIDED BY THIS CONTRACT (UNLESS OTHERWISE NOTED). CONDENSATE DRAINS FOR ALL ROOF MOUNTED EQUIPMENT AND EQUIPMENT PROVIDED IN MECHANICAL ROOMS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR (UNLESS OTHERWISE NOTED).4.FSNOTE: PC TO PROVIDE EZ TRAP MODEL EZT-225 FLOW SWITCH TO SHUT DOWN SYSYTEM ON OVERFLOW.WALL3/4"1 1/2"P-TRAPSINK/LAVWALLFINISHED FLOOR1 1/2"VWIWCONNECT IW TO TAILPIECE (VIA AIR BREAK) UPSTREAM OF TRAPPROVIDE THIS BALANCING VALVE ARRANGEMENT AT EACH LOCATION WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS INTERSECT ON HOT WATER RETURN LINES.FLOWNOTE:CHECK VALVEBALL VALVEBALANCE VALVESIZE AS NOTEDON FLOOR PLANSHWRBALANCING VALVE SIZE:GPM RANGE:3/4"1"1 1/4"1 1/2"2"2 1/2"3"UP TO 3.03.1 - 7.07.1 - 1213 - 2223 - 4546 - 7071 - 1404"141 - 2804" CONC. PADNOTE:P.C. SHALL WIRE LOW PRESSURE SUCTION SWITCH BACKTO PUMP CONTROL PANEL. SWITCH SHALL SHUT DOWNPUMPS IF INCOMING LINE PRESSURE FALLS BELOW 20 PSI4" GATE VALVE (TYP.)4" CHECK VALVE(RESILIENT SEAT)4" SUPPLYLOW PRESSURESUCTION SWITCH SET AT 20 PSIPRESSUREGAUGE (TYP.)ISOLATIONVALVE (TYP.)FLANGE (TYP.)CONTROL PANELALL WORK BY P.C.BALL VALVEUNIONDRAIN VALVEFINISHED FLOORDOMESTICBLADDER TANK(DBT-1)ALL WORK INSIDE BOXPROVIDED AS PART OFFACTORY PACKAGED UNIT4" DISCHARGEAQUASTAT2"4"PRVDBP-1PRV2"DBP-1LIFT CHECK VALVE1 1/2" IW3 3/8"COORDINATE HEIGHT OF PUMPDISCHARGE WITH ELEVATORCONTRACTOR AND FINISHED FLOORELEVATIONRECEPTACLE BY ELECTRIC CONTRACTORTURN ONLEVEL 1"BELOW PITFLOORTURN OFF LEVELELEVATOR SUMP PUMP (ESP-1)UNIONC.O.CAST IRONPIPE SLEEVESEAL WATERTIGHT2" IW. REFER TO PLANSFOR CONTINUATIONPROVIDE LINK-SEAL2"x2"x1 1/2" WYEELEVATORPIT FLOORSHUT OFF VALVE(GATE VALVE)TIGHT TO PIT WALL1 1/2" IW1.BACKFLOW PREVENTER(S) MUST BE A MINIMUM OF 30" ANDMAXIMUM OF 60" ABOVE THE FINISHED FLOOR.2.BACKFLOW PREVENTER(S) INSTALL ABOVE 60", MUST BEPROVIDED WITH AN OSHA APPROVED SCAFFOLD PLATFORM ONSITE FOR REQUIRED TESTING AND INSPECTION OF BACKFLOWDEVICE(S).3. BACKFLOW PREVENTER(S) CLEARANCES:- MINIMUM 36" CLEAR IN FRONT OF DEVICE(S)- MINIMUM 12" CLEAR BEHIND DEVICE(S)- MINIMUM 24" CLEAR ABOVE DEVICE(S)4. DOMESTIC METER HEIGHT LIMITS 18" MIN. - 40" MAX.5.THE BACKFLOW PREVENTER(S) ARE LOCATED IN AN ADEQUATELYHEATED AND LIGHTED AREA TO PREVENT FREEZING AND ALLOWFOR MAINTENANCE AND TESTING OF THE DEVICE(S).NOTES:6. ALL MATERIAL BEFORE BACKFLOW PREVENTER(S) TO BE BRASS, COPPER OR CEMENT LINED DUCTILE IRON. VICTAULIC GROOVED/ROLLED PIPING AND FITTINGS ARE NOT ACCEPTABLE UPSTREAM OF THE BACKFLOW PREVENTER(S).7. AIR GAP FITTINGS ARE NOT ALLOWED.6X4 TEE SLEEVE &SEAL (TYPICAL)6" COMBINEDWATER SERVICEBY FPC6" OS&Y VALVE WITHTAMPER SWITCH30"4" GATE VALVE(TYPICAL)3" METERW/UNIONSPLATESTRAINER4" BYPASSTO FIRESERVICE4"6"4" REDUCED PRESSURE ZONE (RPZ)MAKE: WATTS LF957. PROVIDE A 6x4FUNNEL FITTING CENTERED UNDERRPZ RELIEF VALVE. RPZ RELIEF GAPSHALL BE A MINIMUM OF TWO TIMESTHE RPZ DISCHARGE OPENING4" COLD TOBOOSTER PUMPSPIPESUPPORT TYPICAL)TERMINATE 6" IW AT BLDG'SEXTERIOR 12" ABOVEFINISHED GRADE WITHTURNED DOWN ELBOW,12x12 SPLASH BLOCK, BUGSCREEN AND FLAPPER VALVE.2" REDUCED PRESSURE ZONE (RPZ)MAKE: WATTS LF909. PROVIDE A 6x4FUNNEL FITTING CENTERED UNDERRPZ RELIEF VALVE. RPZ RELIEF GAPSHALL BE A MINIMUM OF TWO TIMESTHE RPZ DISCHARGE OPENING4"TERMINATE 4" IW AT BLDG'SEXTERIOR 12" ABOVEFINISHED GRADE WITHTURNED DOWN ELBOW,12x12 SPLASH BLOCK, BUGSCREEN AND FLAPPER VALVE.30"1. COORDINATE WITH ELECTRICAL CONTRACTOR FOR EXACT REQUIREMENTS.2. PROVIDE INLET AND OUTLET OUTDOOR AIR KIT.3. PROVIDE 24" DEEP HEAT TRAP ON HOT WATER SUPPLY.4. PROVIDE DRAIN PAN UNDER HEATER.5. COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS).6. STORAGE TEMPERATURE SHALL BE 140 F.7. PROVIDE PRV ON COLD WATER INLET TO HEATER IF PRESSURE EXCEEDS 55 PSI.NOTES:DRAIN PANDRAIN VALVEFINISHED FLOORHEAT PUMP ELECTRIC HOT WATER HEATER(HWH-1)SHUT-OFF VALVE (TYP.)RUN T&P RELIEF VALVE TO ADJACENT MOP SERVICE SINKUNION (TYP.)THERMOMETER (TYP.)2"1"CH 115SPRING CHECK VALVE (TYP.)STRAINER WITHBLOWDOWN VALVEHWR PUMP(HWRP-1 )BALANCING VALVEHWRMIXING VALVE (MV-1)1"3/4"EXPANSION TANK (DET-1)MIXING VALVE (MV-1)1"CHT&P GAUGESET AT 110° F2"PROVIDE PRESSURE REDUCING VALVE (PRV) IF PRESSUVRE EXCEEDS 60 PSI. SET PRV TO 55 PSISPRAY SPRAY HEAD WITH FLIP-TOP DUST COVER, INTERNAL FLOW CONTROL AND FILTER (TYP.OF 2)NOTES:1. PROVIDE GUARDIAN MODEL G5022 DECK MOUNTED EYEWASH (EW-1)2. PROVIDE IN-LINE VACUUM BREAKEREW-ACOUNTERTOPSTAINLESS STEEL SQUEEZE HANDLE WITH PLASTIC COVERNYLON HANDLEPROVIDE SHUT-OFFAND CHECK VALVES AS SHOWN (TYP.)UNION (TYP.)PROVIDE POWERSHYDROGUARD ES150SERIES MIXING VALVE (MV-2)CHTEMPID WATER INLETPROVIDE 1/2" HOT AND 1/2" COLD FROM SINK PIPINGSPRAY SPRAY HEAD WITH FLIP-TOP DUST COVER, INTERNAL FLOW CONTROL AND FILTER (TYP.OF 2)NOTES:1. PROVIDE GUARDIAN MODEL G1819 WALL MOUNTED EYEWASH (EW-2)2. PROVIDE IN-LINE VACUUM BREAKEREW-BPROVIDE SHUT-OFFAND CHECK VALVES AS SHOWN (TYP.)UNION (TYP.)PROVIDE POWERSHYDROGUARD ES150SERIES MIXING VALVE (MV-2)CHTEMPID WATER INLET1/2" HOT AND 1/2" COLD FROM SINK PIPINGINSULATIONFLASHING CLAMPDECK FLANGEUNDER DECKCLAMPSET SCREWS3/4" COLDWATER LINEROOF DECKINGMETAL DECKWATERPROOFINGWATER TIGHTSEALANT53 1/2"17" MIN43" MAX1/8" NPTDRAIN HOLENOTES:1. PROVIDE HYDRANT WITH VACUUM BREAKER.2. DRAIN HOLE SHALL BE PIPED AND DISCHARGED TO ANACCEPTABLE DISCHARGE POINT.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:23 PMP501DETAILS02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3CONDENSATE DRAIN CONNECTION2INDIRECT CONNECTION TO LAV/SINK4HWR BALANCE VALVE ARRANGEMENT5BOOSTER PUMP6ELEVATOR SUMP PUMP1DOMESTIC WATER SERVICE7HEAT PUMP HOT WATER HEATER8DECK MOUNTED EYEWASH AT SINK9WALL MOUNTED EYEWASH AT MSS10NON-FREEZE ROOF HYDRANTREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 VDTSTGFSFZHHPSTSTXTVDTDNCCNONCCNOVDSIZEMINMAXCFMSIZEMARK30"x18"18"x18"30"x18"12"x12"12"ø12"x10"ø18"x18"12"ø18"ø12"ø12"x12"12"ø12"x10"ø30"x18"18"ø18"x18"30"x18"18"x18"30"x18"30"x18"18"ø18"x18"12"ø18"ø12"ø12"ø18"ø12"ø18"ø18"x18"18"x18"18"ø18"ø18"ø18"ø12"ø12"ø12"ø12"ø10"ø10"ø12"x18"12"x18"18"x18"18"x18"18"x18"12"x18"12"x18"12"x18"12"x18"18"x18"18"x18"12"ø12"øAADBDDFSFDMDSDDSDNICNOT IN CONTRACTPIPE GUIDEPIPE ANCHOREND CAPAIR SEPARATORDUCT SPLIT - RADIUS ELBOW(SIZE INDICATED)(SIZE INDICATED)DUCT SPLIT - SQUARE ELBOWAND BOURDON TUBEPRESSURE GAUGE WITH GAUGE COCKPRESSURE GAUGE WITH GAUGE COCKFLEXIBLE DUCT (SIZE PER TABLE,THIS SHEET)45° LATERAL, ROUND TO ROUND45° CONICAL LATERAL, ROUND TO ROUNDPUMP - GENERICFLOW METERHUMIDISTAT - WALL MOUNTEDTHERMOSTAT - DUCT MOUNTEDTRANSITION - RECTANGULAR TOSHORT RADIUS ELBOW - 90°RETURN/EXHAUST AIR REGISTER/GRILLESUPPLY AIR DIFFUSER/GRILLELINEAR DIFFUSERTRANSFER AIR DESIGNATIONSUPPLY AIR DESIGNATIONRETURN AIR DESIGNATIONEXHAUST AIR DESIGNATIONRETURN/EXHAUST REGISTER, CEILING ORDUCT MOUNTEDOUTSIDE AIR DUCT (UP AND DOWN)SUCTION DIFFUSERPUMP - END SUCTIONY-STRAINERTHERMOMETERPRESSURE/TEMPERATURE TEST FITTINGUNIONFLEXIBLE CONNECTIONTEE CONNECTION - STRAIGHT, DOWN, AND UPAIR VENT - (MANUAL)AUTOMATIC AIR VENTPIPE UP AND DOWNCONCENTRIC REDUCERPITCH OF PIPE, DROP (D) RISE (R)FLOW SWITCHSINGLE LINE DOUBLE LINEDESCRIPTIONSUPPLY/OUTSIDE AIR DUCTRETURN AIR DUCTSUPPLY/OUTSIDE AIR DUCT ELBOWRECTANGULAR (UP AND DOWN)DENOTES RECTANGULAR OR SQUAREDUCT, SIZE IN INCHESDENOTES ROUND DUCT, SIZE IN INCHESDENOTES FLAT OVAL DUCT, SIZEROUND OR FLAT OVAL DUCT SUPPLY/END OF DUCT (CAPPED)SUPPLY AIR TERMINAL, CEILING OR DUCTMOUNTED, SQUARE & RECTANGULAR(SHADED AREA(S) DENOTE # & DIRECTIONOF BLANKED OFF SECTION(S))SIDEWALL AIR TERMINAL WITH VD(ARROWS DENOTE THROW DIRECTION)IN INCHESRECTANGULAR (UP AND DOWN)RETURN DUCT BELOWSQUARE VANED ELBOW - 90°TRANSITION - CONCENTRICTRANSITION - ECCENTRICDUCT RISE (IN DIRECTION OF ARROW)FREEZESTAT (LOW TEMPERATURE DIRECTOR)THERMOSTAT - WALL MOUNTEDHUMIDISTAT - DUCT MOUNTEDCLOSED CELL FOAM ACOUSTICAL LINING -DUCT DIMENSIONS SHOWN INDICATEINSIDE CLEAR DIMENSIONSSYMBOLDESCRIPTIONNOT ALL SYMBOLS, ABBREVIATIONS AND LINE DESIGNATIONS°FDEGREES FAHRENHEITWITH PILOT LIGHTDDC DIRECT DIGITAL CONTROLSBAS BUILDING AUTOMATION SYSTEM(F) FUTURENEW(N)CRCSPOINT OF CONNECTION BETWEEN NEW AND EXISTING WORKPOINT OF DISCONNECT BETWEEN EXISTING AND TO BE REMOVED WORKSECTION LETTERSECTION DRAWING NUMBERWGWBVTRVRVVIBVIVELWATER GAUGEWET BULBVENT THROUGH ROOFVARIABLE REFRIGERANT VOLUMEVIBRATIONVIBRATION ISOLATORVELOCITYVARIABLE AIR VOLUMEVENT OR VOLTSUNIT VENTILATORUNOCCUPIEDUNLESS NOTED OTHERWISEUNIT HEATERUNDERCUTTOTAL STATIC PRESSURETOTAL PRESSURETOP OF STEELTOP OF PIPETOP OF DUCTTEMPERATURETOILET EXHAUST (FAN)TESTING AND BALANCINGTHERMOSTATSTAINLESS STEELVAVVUVUNOCCUNOUHUCTSPTPTOSTOPTODTEMPTE(F)TABTS.S.SQ FTRHRFREFRCPRASQUARE FEETRELATIVE HUMIDITYRETURN AIR FANREFRIGERANTRADIANT CEILING PANELRETURN AIRHORSEPOWER or HEAT PUMPHAND-OFF SELECTOR SWITCHHAND-OFF AUTOMATIC SELECTOR SWITCHARRESTANCE FILTERHIGH EFFICIENCY PARTICULATEHEAT EXCHANGERHEADHEATING COILHUMIDISTATGRAINS PER POUNDGENERAL CONTRACTORGALLONSGALLONS PER MINUTEGALLONS PER HOURGASFREEZESTATFACE VELOCITYFEET WATER GAUGEFEETFLOW SWITCHFEET PER SECONDFEET PER MINUTEHPH/OHOAHEPAHXHDHCHGR/LBGCGALGPMGPHGFZFVFT/WGFTFSFPSFPMPOLYVINYL CHLORIDEPOUNDS PER SQUARE INCH GAUGEPOUND PER SQUARE FOOTPRESSURE SENSOR DUCT STATICPRESSURE REDUCING VALVEPRESSURE REDUCING DEVICEPREHEAT COILPHASEPRESSURE DROPPLUMBING CONTRACTORPROPYLENE GLYCOLPUMPNATURAL GASOUTSIDE DIAMETEROCCUPIEDOPPOSED BLADE DAMPEROUTSIDE AIR INTAKEOUTSIDE AIRNOT TO SCALENORMALLY OPENNORMALLY CLOSEDPVCPSIGPSFPSPRVPRDPHCPHPDPCP.G.PNGODOCCOBDOAIOANTSNONCMOTOR CONTROL CENTERMECHANICAL CONTRACTOR1000 BTU PER HOURLEAVING WATER TEMPERATURELINEAR FEETPOUNDS PER HOURPOUND(S)LEAVING AIR TEMPERATUREKILOWATTINCHES WATER GAUGEINCHINSIDE DIAMETERHERTZHOT WATERHEATING, VENTILATING, AIR CONDITIONINGHUMIDITY OR HUMIDIFIERHEATERMCCMCMBHLWTLFLB/HRLBLATKWIN/WGINIDHzHWHVACHUMHTRFLAT ON TOPFLAT ON BOTTOMFLOW METERFULL LOAD AMPSFIRE DAMPERFAN COIL UNITFORWARD CURVEDFILTER or FANENTERING WATER TEMPERATUREEXPANSION TANKEXTERNAL STATIC PRESSUREEXHAUST FANELECTRIC DUCT HEATEREVAPORATIVE COOLERELECTRICAL CONTRACTOREXHAUST AIRENTERING AIR TEMPERATUREEXISTINGFOTFOBFMFLAFDFCUFCFEWTETESPEFEDHECECEAEAT(E)DIRECT EXPANSIONDUCT SMOKE DETECTORDOMESTICDOWNDIAMETERDEHUMIDIFIERDUST COLLECTORDRY BULBCONSTANT VOLUMECABINET UNIT HEATERCONDENSING UNITCOOLING TOWERCONDENSATE PUMPCHILLERDXDSDDOMDNDIA./ ØDHDCDBCVCUHCUCTCPCHCUBIC FEET PER MINUTECUBIC FEET PER HOURCOOLING COILCOMBUSTION AIRBRITISH THERMAL UNIT PER HOURBRITISH THERMAL UNITBOTTOM OF PIPEBOTTOM OF DUCTBACKWARD INCLINEBRAKE HORSEPOWERBLAST GATEBACKDRAFT DAMPERBOILERAIR SEPARATORACCESS PANELACOUSTICAL LININGAIR HANDLING UNITABOVE FINISHED FLOORACCESS DOORAIR CONDITIONING UNITCFMCFHCCCABTUHBTUBOPBODBIBHPBGBDDBASAPAL or (L)AHUAFFADACGWRGWSHPWRHPWSHWRHWSCWRCWSGLYCOL WATER RETURNGLYCOL WATER SUPPLYHEAT PUMP WATER RETURNHEAT PUMP WATER SUPPLYHOT WATER RETURNHOT WATER SUPPLYCONDENSER WATER RETURNCONDENSER WATER SUPPLYCHILLED WATER RETURNCHILLED WATER SUPPLYARE NECESSARILY USED ON THIS PROJECT.1.TEMPERATURE SWITCHPRESSURE SWITCHDIFFUSER TAGBUTTERFLY VALVEBALANCE VALVEBALL VALVEPRESSURE REGULATING VALVEPRESSURE RELIEF VALVEPRESSURE REDUCING VALVECHECK VALVETRIPLE DUTY VALVEGATE VALVE2-WAY ELECTRIC VALVE2-WAY PNEUMATIC VALVE3-WAY ELECTRIC VALVE3-WAY PNEUMATIC VALVEVACUUM BREAKERTEMPERATURE ELEMENTTEMPERATURE SENSORTHERMOSTAT W/ GUARD - WALL MOUNTEDTEMPERATURE SENSOR - WALL MOUNTEDEXISTING TO REMAINETRPACKAGED TERMINAL AIR CONDITIONERPTACMV12"Ø(L) 12"x12"(L)AUTOMATIC AIR DAMPERAADBOTTOM OF STEELBOSHEAT RECOVERY UNITHRUPACKAGED TERMINAL HEAT PUMPPTHPVRF VARIABLE REFRIGERANT FLOWSPSHSFSARTURPMRHCSTATIC PRESSURESENSIBLE HEATSUPPLY AIR FANSUPPLY AIRROOFTOP UNITREVOLUTIONS PER MINUTEREHEAT COILAUTO AIR DAMPERBACK DRAFT DAMPERFIRE DAMPERMOTORIZED DAMPERSMOKE DAMPERVOLUME DAMPERCOMBINATION FIRE/SMOKE DAMPERDUCT SMOKE DETECTOREXISTING PIPING/DUCTWORKREMOVAL PIPING/DUCTWORKNEW WORK PIPING/DUCTWORKVAV BOX TAGFUME HOODFHTEMPERATURE TRANSMITTERTTVACUUM BREAKERVBVP VACUUM PUMPEXHAUST AIR DUCT ELBOWRECTANGULAR (UP AND DOWN)EXHAUST AIR DUCT90° CONICAL TAKEOFF, ROUND TO90° TAKEOFF, ROUND TO ROUND,ROUND SHOE TAP90° TAKEOFF, RECTANGULAR TOSTRAIGHT SHOE TAPCFMRASAIR DUCT (UP AND DOWN)ROUND OR FLAT OVAL DUCT RETURNAIR DUCT (UP AND DOWN)ROUND OR FLAT OVAL DUCT EXHAUSTROUNDROUNDTS-00P/TFMRDNOTESMISC. SYMBOLSLINE DESIGNATIONSPIPING SYMBOLSDUCTWORK SYMBOLSABBREVIATIONSAVFCMINIMUM REQUIREDTE-00CONTROLS:A#SDA. UNLESS OTHERWISE SPECIFIED IN THESE DOCUMENTS, ALLEXHAUST AND RELIEF FANS SHALL BE CONTROLLED BY TIME CLOCK,TIME CLOCK PROVIDED BY HVAC CONTRACTOR, CONNECTED TOHAND-OFF-AUTO RELAYS OF FAN MOTOR STARTERS, OR START-STOPOF VFD'S. ALL POWER WIRING OF TIME CLOCK BY HVAC CONTRACT.B. ALL EXHAUST AND RELIEF FANS SHALL HAVE POSITIVE CLOSUREDAMPERS INTERLOCKED TO OPEN WHEN FAN IS ENERGIZED,EXCEPTING SMOKE MANAGEMENT SYSTEMS, DRYER VENTS ANDCOOKING EQUIPMENT.C.ALL DIRECT DRIVE FANS SHALL BE PROVIDED WITH SOLID STATEMOTOR CONTROLLERS OR ELECTRONICALLY COMMUTATED MOTORS(ECM) WITH ALL REQUIRED CONTROL DEVICES FOR SPEEDADJUSTMENT OF THE FAN MOTOR.D.FOR ALL HVAC EQUIPMENT (EXCLUDING SMOKE MANAGEMENTSYSTEMS AND COOKING APPLICATIONS) PROVIDE AN INTERLOCK TOTHE MOTORIZED DAMPER SUCH THAT THE DAMPERS WILL CLOSE UPONUNOCCUPIED CONDITION. HVAC CONTRACT TO PROVIDE TIME CLOCKOR DDC CONTROL.E. EACH ZONE SHALL HAVE A 7 DAY-4 FUNCTION PER DAYPROGRAMMABLE CONTROLLER WITH A 5°F DEADBAND AND SETPOINTOVERLAP RESTRICTIONS.F. MINIMUM AUTOMATIC CONTROLS SHALL SETBACK TO 55°F (HEAT)AND 85°F (COOL); 7-DAY CLOCK, 2-HOUR OCCUPANT OVERRIDE,10-HOUR BACKUP.G. PROVIDE ECONOMIZER AND RETURN SIDE DUCT SMOKEDETECTORS ON ALL HVAC EQUIPMENT OVER 2000 CFM.H.PROVIDE EXHAUST AIR ENERGY RECOVERY ON ALL HVACEQUIPMENT OVER 5000 CFM SUPPY.I.SEE SCHEDULES, SPECIFICATIONS, DETAILS AND NOTES WHICHMAY SUPERCEDE THESE MINIMUM PERFORMANCE REQUIREMENTS.TAP AND FLEX DUCT SIZING TABLETAP AND FLEX DUCT SIZE SUPPLY DIFFUSER CFM RANGE RETURN/EXHAUST REGISTER CFM RANGE6"Ø FLEX / DUCT 1 CFM THRU 100 CFM 1 CFM THRU 80 CFM8"Ø FLEX / DUCT 105 CFM THRU 200 CFM 85 CFM THRU 175 CFM10"Ø FLEX / DUCT 205 CFM THRU 400 CFM 180 CFM THRU 300 CFM12"Ø FLEX / DUCT 405 CFM THRU 600 CFM 305 CFM THRU 525 CFMNOTES: 1. PROVIDE A VOLUME DAMPER ON SUPPLY, RETURN, EXHAUST AND OUTSIDE AIR TAPS,BALANCE TO DIFFUSER/REGISTER TAG VOLUME.14"Ø FLEX / DUCT 605 CFM THRU 900 CFM 530 CFM THRU 800 CFMPIPE SIZING SCHEDULESIZEMIN GPM MAX GPM3/4"03.51" 3.6 7.51 1/4" 7.6131 1/2"13.5202"21402 1/2"41753"761204"1212505"2514506"451750NOTES: 1. PIPE SIZING TABLE SHALL BE UTILIZED IF PIPE TAG IS NOT PRESENT.REQUIRED 2020 IECC ENERGY CONSERVATION COMPLIANCECODE SECTIONCOMPLIANCEC303.3 OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER BY CONTRACTOR FOR ALL EQUIPMENTC401.2 BUILDING COMPLIES WITH THE APPLICABLE SECTIONS OF CODE BASED ON METHOD 2C402.5 REFERENCE ARCHITECTURAL PLANS FOR AIR LEAKAGE CRITERIA C403.2.1HVAC LOAD SIZING HAS BEEN PERFORMED IN THE CARRIER HAP PROGRAM, USING RTS (HEAT BALANCE) METHODOLOGYC403.2.3 ALL HVAC EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE MECHANICAL DOCUMENTSC403.2.4 REQUIRED HVAC CONTROLS SHALL BE PROVIDED, REFERENCE MECHANICAL DOCUMENTSC403.2.4.3MOTORIZED DAMPERS PROVIDED FOR EXHAUST AND OUTSIDE AIR INTAKES GREATER THAN 300 CFM OR IN BUILDINGS 3 STORIES OR LESSC403.2.9.1 DUCT IS REQUIRED TO BE INSULATED TO THE INDICATED MINIMUM LEVEL, REFERENCE MECHANICAL DOCUMENTSC403.2.9.3 INSTALLING CONTRACTOR SHALL ENSURE THAT ALL AIR DISTRIBUTION COMPONENTS ARE PROPERLY SEALEDC403.2.9.5 DUCT SIZING AND DUCT DESIGN HAS BEEN PERFORMED, REFERENCE MECHANICAL DOCUMENTSC403.2.10 ALL PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE MECHANICAL / PLUMBING DOCUMENTSC403.2.11 MECHANICAL SYSTEMS SHALL BE COMMISSIONED AS REQUIREDC404.2 ALL WATER HEATING EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE PLUMBING DOCUMENTSC404.4 ALL DOMESTIC HOT WATER PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE PLUMBING DOCUMENTSC405.2 LIGHTING CONTROL CRITERIA HAS BEEN MET, REFERENCE ELECTRICAL DOCUMENTSC405.5 EXTERIOR LIGHTING TOTAL POWER DOES NOT EXCEED THE ALLOWANCE, REFERENCE ELECTRICAL DOCUMENTSC405.6 ELECTRICAL POWER HAS BEEN PROVIDED PER THE CODE REQUIREMENTS, REFERENCE ELECTRICAL DOCUMENTSC408.2.2 INSTALLING CONTRACTOR SHALL TEST AND BALANCE ALL HVAC SYSTEMS AND PROVIDE REPORT TO ENGINEERMECHANICAL DESIGN CONFORMS TO 2020 IECC AND IMC CODE REQUIREMENTSC103.2.1REFERENCE ARCHITECTURAL PLANS FOR FENESTRATION U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSREFERENCE ARCHITECTURAL PLANS FOR AREA-WEIGHTED U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSC103.2.2C103.2.3C103.2.4C103.2.5C103.2.6C103.2.7C103.2.8C103.2.9C103.2.10C103.2.11C103.2.12REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR DUCT AND PIPE INSULATION MATERIALS, ARCHITECTURAL DOCUMENTS FOR ALL OTHER INSULATION MATERIALSREFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENTAMD SYSTEM CONTROLSREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT HORSEPOWER AND CONTROLSREFERENCE MECHANICAL AND PLUMBING SPECIFICATIONS FOR SEALING AND INSULATION LOCATIONSREFERENCE ELECTRICAL DOCUMENTS FOR LIGHTING FIXTURE SCHEDULE AND CONTROLSREFERENCE ELECTRICAL DRAWINGS FOR DAYLIGHTING ZONESREFERENCE MECHANICAL SPECIFICATIONS FOR AIR SEALING DETAILSJ.FOR SMOKE DAMPERS, MC SHALL INSTALL DUCT SMOKE DETECTORS FURNISHED BY OTHERS.RAD FIN TUBE RADIATIONFURNACEFURENERGY RECOVERY VENTILATORERVCCOIL CONDENSATE DRAINREF REFRIGERANT PIPINGCRDCEILING RADIATION DAMPERTO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT, THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE INTERNATIONAL ENERGY CODE, AS ADOPTED BY THE STATE.ENERGY CONSERVATION CODE COMPLIANCE STATEMENTSYMBOLDESCRIPTIONPIPING SYMBOLS CONT.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:11 PMM001LEGEND &ABBREVIATIONS02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE MECHANICAL SCOPE. PIPING, SEALANT AND INSULATION MATERIAL, EQUIPMENT EFFICIENCIES, SPACE PRESSURIZATION REQUIREMENTS, INDOOR AIR QUAILITY REQUIREMENTS, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 230800 AND 019113 FOR COMMISSIONING REQUIREMENTS.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.TTTTTTTTTTTTTTTTTTTTTTTTTTWASTEHOLDING136PUBLICTOILET100AEXAM121EXAM120EXAM115EXAM114CLEANLINENHOLDING137TRIAGE/INTERVIEW106EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V112345ABCE3.8F3.916"x12"FSFSFSFS16"x12"FSFSFSFSSOILEDWORK111EXAM118CLEANSUPPLY134STAFFBREAK133SOILED132REGISTRATION124SPECIMENTOILET127HOLDING/MAIL100CVITALSALCOVE105ACIRCULATION105CIRCULATION105SUB-WAITING105BDFC-15ADFC-07ADFC-05IDFC-15BDFC-09BDFC-07BDFC-24ADFC-24BDFC-12ADFC-09RDFC-30ADFC-05ADFC-15DDFC-05BDFC-12BDFC-07DDFC-15EDFC-12RDFC-05CDFC-05DDFC-09SDFC-18AAC-18BDFC-05HDFC-05GDFC-05FBLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125RADIOLOGY(X-RAY)119CORRIDOR143TREATMENT117EXAM113STATLAB/MED110CLEANHOLDING107BUILDINGMAINTENANCETOILET/SHOWER138A12"ø125010"11808"A27522x10A16022x1010"øA37022x1011006"10"øA9022x101906"1956"1956"A9522x10A9522x108"ø8"ø6"ø6"ø6"ø10"øA18022x10A10022x102256x6A356x6A958x810"ø8"ø11808"2758x86"ø6"ø4"ø8"ø8"ø26"x10"12"ø10"ø2758x82508x831054-1s12008"B53022x10B32022x1011608"11608"8"ø8"ø10"ø10"ø11558"11006"11006"11006"A15522x10A10022x10A10022x10A10022x10PoSPATIENTTOILET105CSHAREDPROVIDEROFFICE104STAFFTOILET103STAFFBREAK102EXAM112RECEPTION101BVISITORTOILET101ALOBBY/WAITING101PUBLICTOILET100BEVS1091756"2758x82858x8A958x8A1058x82858x810"ø6"ø6"ø8 "ø 8 "ø10"ø8"ø8 "ø 11408"12"ø8"ø11508"1 0 "ø 6"ø8"øA49022x2211158"(TYP.2)8"ø6 "ø 1906"MECHANICAL145PROVIDE CEILING RECESSED ELECTRIC HEAT AIR CURTAIN, POWERED AIRE Inc. MODEL CLD-2-72(E) OR APRROVED EQUAL, 72" WIDE, (2)1/2 HP, 20 KW OF ELECTRIC HEAT, 208/3, 58.4 A. PROVIDE SINGLE POINT POWER CONNECTION. PROVIDE BLACK DIFFUSER AND FACTORY WALL MOUNT T-STAT.8"øCORRIDOR12210"ø8"ø11408"11408"(TYP.3)32154'-3s31704'-2sB74022x10A408x8B32022x10A11022x101956"11408"11408"A14022x10A14022x108"ø10"ø10"ø8"ø8"øA14022x10A14022x108"ø10"ø10"ø 8"ø11408"11408"10"ø8"ø6"ø 8 "ø 1 0 "ø 6"ø8 "ø 8"ø11508"A15022x102708x8A908x8A11522x1011158"A7022x1010"ø32004'-2s2808x8A1008x8B28022x1012"x10"10"ø10"ø8"ø8"ø8"ø12"ø6"ø6"ø8"ø6"ø6"ø10"ø8"ø8"ø11208"11208"10"øB33522x1010"ø10"ø128010"B28022x1012008"11006"B60022x22A1208x821008x812008"12"ø10"ø6"ø8"ø14"x10"6"ø1806"124010"B32022x1010"ø10"ø6"ø10"ø214012x6A14012x6A14012x6214012x610"ø10"øB28022x2211408"11408"8"ø10"ø8"ø8"ø6"øA958x814"x10"6"ø11006"6"ø6"øB28022x1010"ø6"ø14"x10"12"x10"6 "ø A64522x1016"x10"8"øA958x82958x810"ø(TYP.3)32754'-3s(TYP.3)14"x10"31804'-2s(TYP.4)8"ø(TYP.4)1 6 "x1 0 "1 2 "x 10 "1 0 "ø 6"ø1 8 "x 1 0 "10"ø(TYP.2)8"ø(TYP.2)B33522x106"ø2608x8A408x86 "ø A11522x10A18022x102017511020590401854521525175708035552408050853520115214"x8"VD14"x8"6"ø8"øV D 18"x8"VD8"øVD6"øVD14"x8"10"x8"VDVD6"ø8"ø8"øVD8"ø8"ø8"ø4"ø4"øVD20VD4"ø16"x10"14"x8"8"ø6"ø10"x8"8"ø6"øVDVD4"øVDVDVD12"x8"VDVD6"ø6"øVD12"øVD8"ø4"øV D V D 4"øVDCUH-1AAC-18A8"ø(TYP.2)A758x82758x86"ø10"ø8"ø6"ø8"ø10"ø8"ø8"øAC-18CELEVA100EAELEVB100EBA1058x8A1108x8A14022x106"ø2908x88"x8"8"ø(TYP.2)8"ø18"ø12"x8"10"ø(TYP.2)8"ø8"ø(TYP.2)10"ø18"x12"12"x10" EA DUCT UP TO FLOOR ABOVE16"x12" OA DUCT DOWN FROM FLOOR ABOVE18"x12" EA DUCT UP TO FLOOR ABOVE16"x12" OA DUCT DOWN FROM FLOOR ABOVE18"x12"8"ø6"ø6"ø8"ø10"ø10"ø12"x10"FSFS10"x10" EA DUCT UP TO FLOOR ABOVE10"x10"10"øAC-1350 lbs.AC-2200 lbs.AC-18BPROVIDE CEILING RECESSED ELECTRIC HEAT AIR CURTAIN, POWERED AIRE Inc. MODEL CLD-1-48(E) OR APRROVED EQUAL, 48" WIDE, (1)1/2 HP, 10 KW OF ELECTRIC HEAT, 208/3, 29.2 A. PROVIDE SINGLE POINT POWER CONNECTION. PROVIDE BLACK DIFFUSER AND FACTORY WALL MOUNT T-STAT.8"ø10"ø(TYP.3)B81022x2211408"12"x8"6"ø8"x8"8"ø8"ø8"ø6"ø8"x8"ø10"BF-1ASTAIR2ST2-1STAIR1ST1-110"øA25522x1016"x10"SDSD3SDSDSDSDSDSDSDSDS DSD SDSDSDSDSDSDSDSDSDSD803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:19 PMM101FIRST FLOORPLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIRST FLOOR PLANNDRAWING NOTES:1PROVIDE 10"Ø DUCTED CONNECTIONS FROM EXHAUST MAIN TO THE INLET AND OUTLET OUTDOOR AIR KIT FOR DOMESTIC WATER HEATER (HWH-1_).PROVIDE TITUS 24x48 CEILING MOUNTED, ROOM SIDE REPLACEABLE, HEPA RETURN FILTER, 10", 0.06" SP AT RATED CFM.PROVIDE DAIKIN VRF SYSTEM TOUCHSCREEN HEAD END CONTROLLER, I-TOUCH MANAGER AT LOCATION SHOWN. COORDINATE FINAL LOCATION WITH OWNER PRIOR TO INSTALLATION.VENTILATION NOTES:1. PROVIDE CONNECTION FROM OA DUCT TO RETURN PLENUM OF DUCTED FAN COIL UNIT WITH VOLUME DAMPER AS SHOWN, BALANCE DAMPER TO CFM INDICATED IN HEX NOTE2GENERAL NOTES:A. PROVIDE RETURN PLENUM AND FIELD FABRICATED FILTER BOX SIZED TO MATCH THE RETURN CONNECTION OF EACH DFC FAN COIL, PLENUM SHALL BE A MINIMUM OF 10" DEEP. PROVIDE A A MERV 8 FILTER AT EACH DFC. B. PROVIDE AEROSEAL COMMERCIAL DUCT SEALING OR APPROVED ALTERNATE TO ALL OUTSIDE AIR AND EXHAUST DUCTWORK SERVING ALL THREE DOAS UNITS.INSTALL PER MANUFACTURER’S WRITTEN INSTRUCTIONS.C. PROVIDE 1" CIRCLE STICKER ON CEILING TILES BELOW VRF INDOOR FAN COILS (DFC'S) TO DENOTE EQUIPMENT LOCATION, FINAL COLOR SELECTION BY ARCH.3REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 TTTTTTTTTTTTTTTTTTTTTTT12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE22314"x12"FSFSFSFSFSFSFSFSRESPITE/LACTATION240STAFFTOILET237CORRIDOR232DFC-18BDFC-15GDFC-05JDFC-15NDFC-18CDF C -2 4 C DF C -3 0 C DFC-07ODFC-05KDF C -1 5 HDFC-05LDF C -0 5 M DF C-0 5 N DFC-12DDFC-09EDFC-09FDFC-12EDFC-09HDFC-24DRESPITE/MEDITATION241CIRCULATION228WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202NURSE214PHYSICIANOFFICE/DICTATION213LAB221EDUCATION/CONFERENCE234IT/ELEC243DFC-09GEXAM212EXAM211EXAM210MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204SHAREDCLERICALOFFICE203EXAM216EXAM215MULTIPURPOSE/ACTIVITY23511708"11708"11006"2908x81506"11308"11108"1806"11308"11108"11058"11058"123510"11006"21058x82858x812008"1506"A25022x101856"11408"11408"OFFICE23811208"11208"130010"130010"A30022x10126510"A1408x821208x821208x8A1408x8126510"DFC-36ADFC-24FTELMED233DFC-15MSTAFFBREAK242STAFFTOILET236RESPITE/LACTATION239A10022x10A12022x10A5022x10A24022x10A12022x10(TYP.2)10"ø8"ø8"ø10"ø8"ø8"ø14"x10"10"ø6"ø8"ø(TYP.2)1506"12"ø10"ø12"ø8"ø8"ø6"ø10"ø8"ø8"ø10"ø6"ø6 "ø 6 "ø 2908x86"ø10"ø10"ø14"x10"6"ø1 0"øA10022x10 A23522x1010"ø8"ø12"x10"10"ø(TYP.2)10"øA10522x10A11022x10B33522x102508x8A6022x10A14022x10A12022x106"ø8"ø8"ø8"ø8"ø6"ø10"ø14"x10"8"ø8"ø6"øA5022x10A42022x10A17022x1012"x10"8"ø8"ø4"ø8"øDENTALOFFICE2306"ø6"ø2308x88"ø14"x10"A14022x10A10522x1010"ø8"ø8"ø8"ø10"ø8"øø8"8"ø2758x8A958x831804'-3s31854'-3s(TYP.4)B53022x10(TYP.2)2858x8A1058x8128010"B28022x10128010"B28022x10A12022x10A20022x1012008"11208"11058"11058"11108"A11022x10A10522x10A10522x102608x8A808x8B28022x10128010"A28022x10A1258x8A1058x8A1108x8A10522x1010"ø10"øA14022x1012"ø10"øB28022x10128010"10"ø12"ø6"ø12"x10"14"x10"8 "ø8"ø 1 0"ø 8"ø8 "ø 1 2"x1 0 "8"ø8"ø6"ø8"øB81022x2212008"12008"1606"10"ø8"ø10"ø10"ø10"ø10"ø11408"8"ø6 "ø 10"ø6 "ø 6 "ø 1 0 "ø 8"ø8"ø10 "ø 8"ø A20022x10TRIAGENURSEALCOVE207A11408"10"ø10"ø10"ø10"øB53022x10A74022x226"ø10"ø8"ø31304'-3s8 "ø 31304'-3s8"ø8"ø8"ø10"ø8"ø14"x10"B60022x2231754'-3s(TYP.2)8"ø16 "x1 0"1 2 "x1 0 "1 0 "ø 12"x10"10"ø8"ø8 "ø8"ø10"ø 8"ø8"ø8"øAC-18D508535351254035110155120153030301004012015523545027011408"VDV D 10"ø8"ø8"ø14"x10"VDVD12"ø10"øVD8"ø4"ø6"ø4"ø10"x10"10"x6"8"ø6"ø4"ø4"øVDVDVDVDVDVD10"x10"10"øVD12"x12"VDVD8"x6"8"ø10"x10"VD4"øVD1108"ø10"øVD6"øCIRCULATION207VDV D 6"øV D 4 "ø 18"x12"V D V D 4"ø8"ø ELEVB200EBELEVA200EA16"x10"A120022x2220"x12"12"x10" EA DUCT UP FROM FLOOR BELOW. 22"x14" EA DUCT UP TO FLOOR ABOVE.16"x12" OA DUCT DOWN TO FLOOR BELOW. 22"x14" OA DUCT DOWN FROM FLOOR ABOVE.20"x14"VDBALANCE VOLUME DAMPER TO 400 CFM16"x12"14"x8"8"ø8"ø10"x8"8"ø8"ø10"x10" EA DUCT UP FROM FLOOR BELOW. 12"x12" EA DUCT UP TO FLOOR ABOVE.FSFS10"ø10"ø10"ø8"ø8"ø8"ø8"ø10"øA508x86"ø16"ø14"x10"16"x12" OA DUCT DOWN TO FLOOR BELOW. 24"x16" OA DUCT DOWN FROM FLOOR ABOVE.18"x12" EA DUCT UP FROM FLOOR BELOW. 20"x20" EA DUCT UP TO FLOOR ABOVE.16"x10"16"x10"BF-1B10"ø10"ø4"øB28022x108"øSTAIRST2-2STAIR1ST1-2WALKINGTRACK200CUH-1CSDSDSDSDSDSDSDSD10"ø2803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:34 PMM102SECONDFLOOR PLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1SECOND FLOOR PLANNVENTILATION NOTES:1. PROVIDE CONNECTION FROM OA DUCT TO RETURN PLENUM OF DUCTED FAN COIL UNIT WITH VOLUME DAMPER AS SHOWN, BALANCE DAMPER TO CFM INDICATED IN HEX NOTEGENERAL NOTES:A. PROVIDE RETURN PLENUM AND FIELD FABRICATED FILTER BOX SIZED TO MATCH THE RETURN CONNECTION OF EACH DFC FAN COIL, PLENUM SHALL BE A MINIMUM OF 10" DEEP. PROVIDE A MERV 8 FILTER AT EACH DFC. B. PROVIDE AEROSEAL COMMERCIAL DUCT SEALING OR APPROVED ALTERNATE TO ALL OUTSIDE AIR AND EXHAUST DUCTWORK SERVING ALL THREE DOAS UNITS.INSTALL PER MANUFACTURER’S WRITTEN INSTRUCTIONS.C. PROVIDE 1" CIRCLE STICKER ON CEILING TILES BELOW VRF INDOOR FAN COILS (DFC'S) TO DENOTE EQUIPMENT LOCATION, FINAL COLOR SELECTION BY ARCH.DRAWING NOTES:1PROVIDE 10"Ø DUCTED CONNECTIONS FROM EXHAUST MAIN TO THE INLET AND OUTLET OUTDOOR AIR KIT FOR DOMESTIC WATER HEATER (HWH-1_).COORDINATE LINEAR DIFFUSER THICKNESS WITH WOOD SLAT CEILING SUBMITTAL PRIOR TO PURCHASE, LINEAR DIFFUSER THICKNESS AND FRAME TO MATCH WOOD SLAT THICKNESS.2REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT12345ABC3.816"x12"FSFSFSFSELEC/DATA323FSFSFSFSEXAM/CONSULT321EXAM/CONSULT313EXAM/CONSULT320EXAM/CONSULT314EXAM/CONSULT319EXAM/CONSULT315EXAM/CONSULT318EXAM/CONSULT316PROVIDEROFFICE317FTRIAGENURSE324SPECIALTYEXAM/TREATMENT326PATIENTTOILET327EXAM/CONSULT328EXAM/CONSULT329PROVIDEROFFICE339ANURSEWORK339EXAM/CONSULT327TRIAGENURSE339BSPECIALTYEXAM/TREATMENT/TELEMED335LAB334PATIENTTOILET335AEXAM/CONSULT331SPECIMENCOLLECTION333GUESTWAITING/CIRCULATION300REGISTRATION301PUBLICTOILET300BPUBLICTOILET300ASTAFFTOILET325PATIENTTOILET326AEXAM/CONSULT322CENTRALCLEANWORK312CENTRALSOILEDWORK311EXAM/CONSULT309EXAM/CONSULT308EXAM/CONSULT307EXAM/CONSULT306PROVIDEROFFICE317ASTAFFBREAKAREA305PATIENTTOILET302OFFICEMANAGER301ASTAFFTOILET305ALABDRAW332SPECIALTYEXAM/TREATMENT303PATIENTVITALSALCOVE310EVS330AC-18EDFC-07LDFC-05ARDFC-05ASDFC-18JDFC-05ATDFC-05AVDFC-05AUDFC-12PDFC-05AWDFC-12QDFC-18KDFC-36CDFC-18LDFC-05AXDFC-05AYDFC-15ODFC-05AZDFC-09ODFC-05BCDFC-05BDDFC-05BEDFC-05BGDFC-05BHDFC-05BIDFC-09QDFC-05BJDFC-07MDFC-09P2808x8A1008x831354'-2s31354'-2s31704'-2s1756"11758"11758"11708"11358"11358"11358"11408"B28022x101706"11258"B32022x22B28022x10128010"A14022x1011408"A14022x1011408"A14022x1011408"A14022x1011408"A14022x1011408"B28022x1011358"11408"A14022x10A11522x10A22522x1012008"11608"128010"B28022x1011408"B32022x101956"B28022x1011058"11058"2708x8A908x8124510"2758x82758x8A958x8A958x8128010"B28022x10128010"B28022x1011006"11408"11408"B28022x1011758"A408x8A53522x1011408"A14022x1011408"A14022x1011408"A14022x10A658x82658x8A1058x82858x8A14022x10A958x82758x8B28022x10128010"10"ø10"ø8"ø(TYP.2)8"ø12"x10"10"x10"6"ø14"x12"6"ø10"ø10"ø10"ø10"ø8"ø10"ø10"ø6"ø6"ø10"ø8"ø(TYP.2)128010"10"ø10"ø122510"128010"B28022x1014"x10"12"x10"10"x10"10"ø6"ø12"x10"10"ø8"ø8"ø8"ø16"x12"14"x10"10"ø(TYP.7)10"ø6"ø6"ø6"ø10"ø12"ø6"ø10"ø128010"8"ø11408"11108"1606"2908x82908x81956"B28022x10B28022x1010"ø10"ø10"ø10"øNURSEWORKAREA317B8"ø8"ø10"ø8"ø10"ø8"ø10"ø(TYP.2)6"ø8"ø(TYP.2)(TYP.2)PATIENTTOILET3368"ø8"ø8"ø10"ø12"x10"8"øA13522x1010"øA7522x10B33522x1010"ø8"øA24522x10A7522x1010"ø8"øNURSEWORKAREA317E11708"11708"11408"11408"11708"8"ø10"øB28022x1010"ø8"ø8"ø8"ø(TYP.2)8"ø10"ø10"ø8"ø8"ø10"øDFC-05BF11408"A14022x1011408"A14022x108"ø10"ø8"ø8"ø10"øDFC-05BB11408"A14022x1011408"A14022x108"ø10"ø8"ø8"ø10"øDFC-05BA11408"A14022x1011408"A14022x108"ø10"ø8"ø8"ø10"ø10"ø10"ø10"ø10"ø(TYP.2)12"x10"2808x8A1008x8(TYP.2)6"ø10"ø8"ø8"ø8"ø11708"8"ø(TYP.2)8"ø10"x10"11408"6"ø8"øA22022x108"ø10"x10"10"ø8"øDFC-18I8"ø8"ø10"ø12"ø6"ø(TYP.2)B60022x2211758"12"x10"B53022x1010"ø6"ø6"øEXAM/CONSULT328STAFFCIRCULATION31725654040808050110403551565306035808045158095808040451525156524"x12"B113022x1010"øVDVDVD8"ø4"ø6"ø6"ø(TYP.2)VDVD4"ø4"ø4"øVDVDVD6"ø6"øVD6"ø6"ø6"ø80VD8"øVD4"ø15VD12"x10"10"øVDVDVDVD6"ø6"ø14"x8"VD14"x10"6"ø14"x8"VDVDVD6"ø(TYP.2)VD6"ø10"x8"8"x8"VD6"ø8"øVDVDVD6"ø6"ø4"ø6"øVDVD4"ø10"ø12"x8"B60022x2212"x8"6"øVD6"ø8"ø10"ø8"ø4"øCUH-1B8"ø8"øVD4"øELEVA300EAELEVB300EB12"x10"6"ø11208"B60022x22VD14"x10"8"ø8"ø14"x10"6"ø8"ø16"x12"8"ø8"ø8"ø12"x8"24"x16" OA DUCT DOWN TO FLOOR BELOW. 24"x20" OA DUCT DOWN FROM FLOOR ABOVE.20"x20" EA DUCT UP FROM FLOOR BELOW. 22"x20" EA DUCT UP TO FLOOR ABOVE.8"ø12"x12" EA DUCT UP FROM FLOOR BELOW. 14"x14" EA DUCT UP TO FLOOR ABOVE.FSFS6"ø12"x8"8"ø8"ø22"x14" EA DUCT UP FROM FLOOR BELOW. 22"x20" EA DUCT UP TO FLOOR ABOVE.22"x14" OA DUCT DOWN TO FLOOR BELOW. 22"x20" OA DUCT DOWN FROM FLOOR ABOVE.A1108x88"ø8"ø10"ø16"x12"6"ø10"ø1(TYP.2)8"ø8"ø10"øA1108x88"ø8"ø10"øBF-1C8"ø10"ø10"øVD10"ø8"ø10"ø10"ø8"ø6"ø8"ø8"ø8"ø8"ø8"ø8"ø8"ø(TYP.2)8"ø(TYP.2)STAIR1ST1-3STAIR2ST2-3CUH-1DAC-24C222803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:52 PMM103THIRD FLOORPLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1THIRD FLOOR PLANNVENTILATION NOTES:1. PROVIDE CONNECTION FROM OA DUCT TO RETURN PLENUM OF DUCTED FAN COIL UNIT WITH VOLUME DAMPER AS SHOWN, BALANCE DAMPER TO CFM INDICATED IN HEX NOTEGENERAL NOTES:A. PROVIDE RETURN PLENUM AND FIELD FABRICATED FILTER BOX SIZED TO MATCH THE RETURN CONNECTION OF EACH DFC FAN COIL, PLENUM SHALL BE A MINIMUM OF 10" DEEP. PROVIDE A MERV 8 FILTER AT EACH DFC. B. PROVIDE AEROSEAL COMMERCIAL DUCT SEALING OR APPROVED ALTERNATE TO ALL OUTSIDE AIR AND EXHAUST DUCTWORK SERVING ALL THREE DOAS UNITS.INSTALL PER MANUFACTURER’S WRITTEN INSTRUCTIONS.C. PROVIDE 1" CIRCLE STICKER ON CEILING TILES BELOW VRF INDOOR FAN COILS (DFC'S) TO DENOTE EQUIPMENT LOCATION, FINAL COLOR SELECTION BY ARCH.DRAWING NOTES:1PROVIDE 10"Ø DUCTED CONNECTIONS FROM EXHAUST MAIN TO THE INLET AND OUTLET OUTDOOR AIR KIT FOR DOMESTIC WATER HEATER (HWH-1_).COORDINATE LINEAR DIFFUSER THICKNESS WITH WOOD SLAT CEILING SUBMITTAL PRIOR TO PURCHASE, LINEAR DIFFUSER THICKNESS AND FRAME TO MATCH WOOD SLAT THICKNESS.2REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT1234ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414PATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BSTAFFTOILET44516"x12"16"x12"16"x12"FSFSFSFSFSFSEVS439DFC-15IDFC-30BDFC-07EDFC-05ODFC-05AODFC-15JDFC-09IDFC-15KDFC-18EDFC-12FDFC-12GDFC-05QDFC-05RDFC-05SDFC-12HDFC-07FDFC-09JDFC-12SDFC-15LDFC-05TDFC-07HDFC-12JDFC-05PDFC-07IDFC-12KDFC-12LDFC-07PAC-18GAC-18FPROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418ACIRCULATION412HOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS417DFC-05UDFC-05XPROCEDUREROOM440STORAGE404A23522x1010"ø11708"11108"11708"1906"11758"1706"A9022x10A5022x10A24522x1011158"11158"128010"123510"A23522x10126510"A26522x10B28022x10128010"2708x821008x8128010"B28022x10137510"2858x82358x82758x82508x8A20022x10B28022x10126510"126510"B45022x1012008"12008"12058"12058"A11022x10A17022x10128010"B28022x10B32022x10132010"B28022x10A1008x82758x811858"1906"A21022x10A7022x10A46022x10A958x8A1058x82358x8A1208x8A908x8B28022x10DFC-12I2858x81806"1906"DFC-07QB33522x10128010"B28022x10B32022x10124010"A308x82308x8EQUIPMENTSTORAGE431A125010"A25022x10128010"2958x8A958x82958x82908x8120510"A908x8A958x812008"A20022x101806"A8022x1011208"11158"12008"12008"12008"B60022x22A31522x1011006"A10022x1011006"1956"2858x82808x82808x8PUBLICTOILET400AA1008x8A1008x811858"31704-2s31704-2sC1704-2sC1704-2s10"ø10"ø2758x8A858x8A908x82708x8A37522x10DFC-07N1856"B33522x2211258"FSFS11408"11408"B28022x1011458"31554'-2s31604'-2s12"ø10"ø6"ø6"ø31654'-2s2208x84"øWOMEN'SCIRCULATION4078015530501525540705511540605015752510595853513017055907015751512"ø12"x10"10"ø8"ø6"ø8"ø8"ø6"ø16"x10"16"x10"10"ø8"ø(TYP.2)8"ø10"ø8"ø(TYP.2)10"ø10"ø10"ø8"ø12"ø10"ø8"ø8"ø(TYP.2)8"ø8"ø12"ø8"ø10"ø10"ø10"ø10"ø10"ø6"ø6"ø6"ø6"ø(TYP.2)8"ø10"ø8"ø10"ø6"ø10"ø10"ø10"ø10"ø6"ø10"ø(TYP.3)10"ø6"ø10"ø10"ø6"ø8"ø8"ø8"ø10"ø10"ø10"ø10"ø6"ø6"ø6"ø10"ø6"ø10"ø10"ø10"ø6"ø10"ø10"ø8"ø8"ø10"ø10"ø10"ø10"ø8"ø10"ø6"ø10"ø10"ø8"ø10"ø8"ø6"ø6"øDFC-07G ON 5TH FLOOR8"øB28022x10A22022x10B53022x1010"ø(TYP.2)8"ø12"x8"12"x10"8"ø6"ø18"x8"6"ø708"ø8"øA208x82208x814"x10"6"ø8"ø8"ø6"øA1058x812"ø1806"10"ø6"ø10"øA10022x10A7022x1010"ø10"øA15522x108"ø11258"6"ø2510"øVDVD10"øVD6"øVD8"øVD4"øVD5510"øVDVD5010"ø14"x10"VD6"øVD10"øVD8"ø12"x10"6"ø6"øVD10"ø12"x10"VD(TYP.2)VDVDVD8"ø6"ø4"ø6"ø16"x10"6"ø10"øVD6"ø6"ø6"ø6"ø8"ø6"øVD6"øVD8"øVDVD4"øVDVD6"ø8"ø6"ø6"øVDVD10"ø14"x10"6"øVD4"ø4"ø6"øVDVD12"x10"VDVD6"ø8"x8"8"øVDELEVA400EAELEVB400EB14"x14" EA DUCT UP FROM FLOOR BELOW. 16"x16" EA DUCT UP TO FLOOR ABOVE.10"ø10"ø10"x10"FSFS24"x20" OA DUCT DOWN TO FLOOR BELOW. 30"x20" OA DUCT DOWN FROM FLOOR ABOVE.22"x20" EA DUCT UP FROM FLOOR BELOW. 24"x20" EA DUCT UP TO FLOOR ABOVE.12"x10"8"ø8"ø8"ø8"ø22"x20" EA DUCT UP FROM FLOOR BELOW. 26"x20" EA DUCT UP TO FLOOR ABOVE.22"x20" OA DUCT DOWN TO FLOOR BELOW. 28"x20" OA DUCT DOWN FROM FLOOR ABOVE.8"ø8"ø10"øA508x86"øA708x88"øVD6"ø8"øA1058x810"ø10"ø10"ø18"x8"8"ø6"ø6"øBF-1D12"x10"10"øB28022x10128010"A32522x1012"x8"A33022x108"øRESULTSALCOVE410WOMEN'SSUB-WAIT4096"ø6"ø14"x10"8"ø10"ø6"ø6"ø8"ø10"ø6"øA358x88"ø8"ø6"ø6"ø8"ø6"ø10"ø4"ø4"ø10"ø10"ø4"øSTAIR2ST2-4STAIR1ST1-48"ø8"ø8"ø2222222B28022x10803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:03:11 PMM104FOURTHFLOOR PLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FOURTH FLOOR PLANNVENTILATION NOTES:1. PROVIDE CONNECTION FROM OA DUCT TO RETURN PLENUM OF DUCTED FAN COIL UNIT WITH VOLUME DAMPER AS SHOWN, BALANCE DAMPER TO CFM INDICATED IN HEX NOTEGENERAL NOTES:A. PROVIDE RETURN PLENUM AND FIELD FABRICATED FILTER BOX SIZED TO MATCH THE RETURN CONNECTION OF EACH DFC FAN COIL, PLENUM SHALL BE A MINIMUM OF 10" DEEP. PROVIDE A MERV 8 FILTER AT EACH DFC. B. PROVIDE AEROSEAL COMMERCIAL DUCT SEALING OR APPROVED ALTERNATE TO ALL OUTSIDE AIR AND EXHAUST DUCTWORK SERVING ALL THREE DOAS UNITS.INSTALL PER MANUFACTURER’S WRITTEN INSTRUCTIONS.C. PROVIDE 1" CIRCLE STICKER ON CEILING TILES BELOW VRF INDOOR FAN COILS (DFC'S) TO DENOTE EQUIPMENT LOCATION, FINAL COLOR SELECTION BY ARCH.DRAWING NOTES:1PROVIDE 10"Ø DUCTED CONNECTIONS FROM EXHAUST MAIN TO THE INLET AND OUTLET OUTDOOR AIR KIT FOR DOMESTIC WATER HEATER (HWH-1_).COORDINATE LINEAR DIFFUSER THICKNESS WITH WOOD SLAT CEILING SUBMITTAL PRIOR TO PURCHASE, LINEAR DIFFUSER THICKNESS AND FRAME TO MATCH WOOD SLAT THICKNESS.2REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 TTTTTTTTTTTTTTTTTTTTTTTTTTTTTT12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507EXAM/CONSULT522PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529EXAM/CONSULT531SPECIALTYEXAM/TREATMENT526PATIENTTOILET527PATIENTTOILET526ASTAFFCIRCULATION517CIRCULATION504BBNURSEWORKAREA517BSPECIALTYEXAM/TREATMENT506CIRCULATION517DNURSEWORKAREA517EIT/ELEC523PROVIDEROFFICE517FREGISTRATION502OFFICEMANAGER502APATIENTTOILET503STAFFBREAKAREA505STAIR3ST3-5PUBLICTOILET501APUBLICTOILET501BELEVA500EAELEVB500EBELEVATORCONTROLROOM500LAB534LABDRAW532SPECIMENCOLLECTION533STAIR1ST1-5PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535EXAM/CONSULT537FSFSFSFSFSFSFSFSCENTRALSOILEDWORK511STAFFTOILET505ACIRCULATION504DFC-07JAC-18IDFC-05AMAC-18HEXAM/CONSULT538CIRCULATION504EVS53028"x20"DFC-07GA14022x1011408"A14022x1011408"11408"11408"B28022x10A608x810"ø10"ø8"ø(TYP.2)DFC-18MDFC-05YDFC-05Z128010"B28022x10128010"B28022x1010"ø10"ø10"ø10"ø11006"11758"A53522x10A658x82858x88"ø(TYP.2)(TYP.2)DFC-18FTRIAGENURSE539BPATIENTTOILET536A1058x8DFC-05AB11408"A14022x1010"ø11408"8"ø10"ø8"ø8"ø8"ø12"x10"10"x10"8"ø6"ø2658x8DFC-05AA11408"A14022x1011408"A14022x108"ø8"ø8"ø10"ø8"øDFC-05ACA958x8B28022x10128010"10"ø10"øDFC-12N2758x86"ø11108"1606"2908x88"øA13522x1010"øA7522x10A33522x10DFC-18GB60022x22A1008x82808x8A1008x831354'-2s31354'-2s31704'-2s12"x10"10"ø8"ø8"ø8"ø(TYP.2)8"ø10"x10"6"ø(TYP.2)DFC-36B11708"8"ø16"x12"14"x10"10"ø(TYP.7)11708"11708"11408"11408"11708"11708"DFC-18H1756"11758"14"x10"12"x10"10"x10"10"ø6"ø8"ø8"ø8"øB60022x2211758"11758"GUESTWAITING/CIRCULATION501DFC-05AD128010"B28022x1010"ø10"øDFC-15PB53022x10122010"(TYP.2)12"x10"21008x8A1208x8(TYP.2)6"ø10"ø12"x10"DFC-09KDFC-09M11608"11608"B32022x101706"11258"11258"B32022x2210"ø10"ø6"ø10"ø10"ø(TYP.2)8"øDFC-05AP11058"11058"2708x8A908x810"ø6"øB28022x108"øDFC-09N124510"2758x8A958x8A958x86"øA24522x10A7522x1010"ø10"ø10"ø8"ø8"ø8"ø10"øDFC-05AQB28022x1011408"10"ø11408"8"øEXAM/CONSULT520EXAM/CONSULT519DFC-05ALA14022x1011408"A14022x1011408"10"ø8"ø8"ø8"ø10"øEXAM/CONSULT513EXAM/CONSULT514EXAM/CONSULT515EXAM/CONSULT516DFC-05AI11408"A14022x1011408"A14022x108"ø10"ø8"ø8"ø10"øDFC-05AJ11408"A14022x1011408"A14022x108"ø10"ø8"ø8"ø10"øDFC-09L11258"B32022x108"ø10"ø10"øPROVIDEROFFICE517ADFC-05AH128010"B28022x1010"ø10"øDFC-05AF11408"A14022x1011408"A14022x108"ø10"ø8"ø8"ø10"øDFC-05AG11408"A14022x1011408"A14022x108"ø10"ø8"ø8"ø10"øEXAM/CONSULT509EXAM/CONSULT508DFC-05AE1956"B28022x102908x81956"6"ø6"ø10"ø6"øDFC-12O11358"A11522x10A22522x1012008"8"øA22022x1010"x10"10"ø8"ø8"ø10"øEXAM/CONSULT518DFC-05AKB28022x10128010"10"ø10"øDFC-05AN10"ø10"ø128010"B28022x1011358"11358"11358"11208"2758x812"x10"8"ø10"x10"8"ø10"øB60022x1010"ø8"ø8"ø31404'-2s31404'-2s10"øCENTRALCLEANWORK512STAFFTOILET525TRIAGENURSE524PATIENTVITALSALCOVE510STAIRVESTIBULE504A2565404080805011040355156530603580804515158080958080404515251565B113022x1020"x16"VD14"x12"10"ø16"x10"6"øVD6"ø14"x10"VD4"ø10"øVD12"x8"8"øVD8"øA14022x106"ø(TYP.2)VDVDø10"VD10"øVD6"øVD8"ø8"x8"VD4"ø6"øVDVD6"ø6"ø6"ø10"x8"VD6"ø8"ø8"øVD6"ø6"ø6"ø8"øVDVD6"ø4"øVD4"øVDVDVD6"ø8"øB28022x10VDVD4"ø6"øVD6"ø10"ø8"ø12"x10"4"øVD6"øVD10"øVDFSFS18"x16"AADAAD16"x16"16"x16"16"x16"26"x20" EA DUCT UP FROM FLOOR BELOW28"x20" OA DUCT DOWN TO FLOOR BELOW24"x20"30"x20" OA DUCT DOWN TO FLOOR BELOW 24"x20" EA DUCT UP FROM FLOOR BELOW 8"ø8"øVD20"x12"10"ø8"ø6"ø6"ø6"ø114"x8"6"ø6"ø(TYP.2)A1108x88"ø8"øVDVD4"ø8"ø8"ø8"x8"8"ø8"ø14"x10"12"x8"8"x8"8"ø8"ø10"ø32426"x20"30"x20"10"ø6"ø6"ø8"ø16"x16" EA DUCT UP FROM FLOOR BELOW6"ø8"ø8"ø8"ø4"ø8"ø6"ø510"ø8"ø8"ø8"ø8"ø8"ø8"ø30"x20"6"ø4"ø8"ø(TYP.2)(TYP.2)STAIR2ST2-5REGISTRATION502AC-24BSDSDSDSD666BF-1E803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:03:30 PMM105FIFTH FLOORPLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIFTH FLOOR PLANNVENTILATION NOTES:1. PROVIDE CONNECTION FROM OA DUCT TO RETURN PLENUM OF DUCTED FAN COIL UNIT WITH VOLUME DAMPER AS SHOWN, BALANCE DAMPER TO CFM INDICATED IN HEX NOTEDRAWING NOTES:1PROVIDE 10"Ø DUCTED CONNECTIONS FROM EXHAUST MAIN TO THE INLET AND OUTLET OUTDOOR AIR KIT FOR DOMESTIC WATER HEATER (HWH-1_).20"x16" OA DUCT DOWN FROM DOAS-1 ON ROOF. 20"x12" EA DUCT UP TO DOAS-1 ON ROOF.28"x20" OA DUCT DOWN FROM DOAS-2 ON ROOF. 26"x20" EA DUCT UP TO DOAS-2 ON ROOF.30"x20" OA DUCT DOWN FROM DOAS-3 ON ROOF. 24"x20" EA DUCT UP TO DOAS-3 ON ROOF.18"x16" EA DUCT UP TO EF-1560 ON ROOF.COORDINATE LINEAR DIFFUSER THICKNESS WITH WOOD SLAT CEILING SUBMITTAL PRIOR TO PURCHASE, LINEAR DIFFUSER THICKNESS AND FRAME TO MATCH WOOD SLAT THICKNESS.2345GENERAL NOTES:A. PROVIDE RETURN PLENUM AND FIELD FABRICATED FILTER BOX SIZED TO MATCH THE RETURN CONNECTION OF EACH DFC FAN COIL, PLENUM SHALL BE A MINIMUM OF 10" DEEP. PROVIDE A MERV 8 FILTER AT EACH DFC. B. PROVIDE AEROSEAL COMMERCIAL DUCT SEALING OR APPROVED ALTERNATE TO ALL OUTSIDE AIR AND EXHAUST DUCTWORK SERVING ALL THREE DOAS UNITS.INSTALL PER MANUFACTURER’S WRITTEN INSTRUCTIONS.C. PROVIDE 1" CIRCLE STICKER ON CEILING TILES BELOW VRF INDOOR FAN COILS (DFC'S) TO DENOTE EQUIPMENT LOCATION, FINAL COLOR SELECTION BY ARCH.6REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABCE3.8F3.9DOAS-1DOAS-3DOAS-23500 lbs.3500 lbs.3000 lbs.ACCU-1ESERVES 5TH FLOOR ONLYSERVES FLOORS 1 THRU 4SERVES FLOORS 1 THRU 4ACCU-1NACCU-2EACCU-2NACCU-3EACCU-3NACCU-4EACCU-4N750 lbs. (TYP. 15)ACCU-5EACCU-5NACCU-1WACCU-2WACCU-3WACCU-4WSTRUCTURAL ENGINEER TO PROVIDE 24" HIGH STANDS TO MOUNT ACCU'S TOACCU-5WACCU-5SACCU-4SACCU-3SACCU-2SACCU-1S750 lbs. (TYP. 5)PROVIDE CONDENSING UNITS ON STANDS, STANDS BY OTHERS. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS, MAINTAIN ALL REQUIRED CLEARANCES.VRF PIPING FROM 1ST THRU 4TH FLOOR ACCU'S DOWN THRU CHASE TO FLOORS BELOW, (TYP.12)VRF PIPING FROM 5TH FLOOR ACCU'S DOWN TO FLOOR BELOW, (TYP.3)VRF PIPING FROM 1ST THRU 4TH FLOOR ACCU'S DOWN THRU CHASE TO FLOORS BELOW, (TYP.4)X26"x20"24"x20"XX20"x12"CU-18ACU-18B150 lbs. (TYP. 11)CU-18CCU-18DCU-18ECU-18FCU-18GCU-18HCU-18IPROVIDE PIPE SUPPORTS EVERY 24", SECURE PIPE SUPPORT TO ROOF DECK. MAINTAIN A MINIMUM OF 24" FROM THE BOTTOM OF THE PIPE TO THE TOP OF ROOF, REFER TO ARCH PLANS FOR ROOF THICKNESS.PROVIDE PIPE SUPPORTS EVERY 24", SECURE PIPE SUPPORT TO ROOF DECK. MAINTAIN A MINIMUM OF 24" FROM THE BOTTOM OF THE PIPE TO THE TOP OF ROOF, REFER TO ARCH PLANS FOR ROOF THICKNESS.PROVIDE DUCY SUPPORTS EVERY 48", SECURE DUCT SUPPORT TO ROOF DECK. MAINTAIN A MINIMUM OF 24" FROM THE BOTTOM OF THE DUCT TO THE TOP OF ROOF, REFER TO ARCH PLANS FOR ROOF THICKNESS.PROVIDE DUCY SUPPORTS EVERY 48", SECURE DUCT SUPPORT TO ROOF DECK. MAINTAIN A MINIMUM OF 24" FROM THE BOTTOM OF THE DUCT TO THE TOP OF ROOF, REFER TO ARCH PLANS FOR ROOF THICKNESS.PROVIDE DUCY SUPPORTS EVERY 48", SECURE DUCT SUPPORT TO ROOF DECK. MAINTAIN A MINIMUM OF 24" FROM THE BOTTOM OF THE DUCT TO THE TOP OF ROOF, REFER TO ARCH PLANS FOR ROOF THICKNESS.VRF PIPING FROM ACCU-5S DOWN TO FLOOR BELOW, (TYP.3)EF-1560150 lbs.CU-24ACU-48AAC-24A803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:03:36 PMM106ROOF PLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1ROOF PLANNGENERAL NOTES:A. PROVIDE AEROSEAL COMMERCIAL DUCT SEALING OR APPROVED ALTERNATE TO ALL OUTSIDE AIR AND EXHAUST DUCTWORK SERVING ALL THREE DOAS UNITS.INSTALL PER MANUFACTURER’S WRITTEN INSTRUCTIONS.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.TT12345ABCE3.8F3.9WASTEHOLDING136PUBLICTOILET100AEXAM121EXAM120EXAM115EXAM114CLEANLINENHOLDING137TRIAGE/INTERVIEW106EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139MAINELECTRICAL142MAINSERVER140VESTIBULE100V2VESTIBULE100V11N1E1W1SSOILEDWORK111EXAM118CLEANSUPPLY134STAFFBREAK133SOILED132REGISTRATION124SPECIMENTOILET127HOLDING/MAIL100CVITALSALCOVE105ACIRCULATION105CIRCULATION105SUB-WAITING105BDFC-15ADFC-07ADFC-05IDFC-15BDFC-09BDFC-07BDFC-24ADFC-24BDFC-12ADFC-09RDF C -3 0 A DFC-05ADFC-15DDFC-05BDFC-12BDFC-07DDFC-15EDFC-12RDFC-05CDFC-05DDFC-09SDFC-18AAC-18BDFC-05HDFC-05GDFC-05FBLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125RADIOLOGY(X-RAY)119CORRIDOR143TREATMENT117EXAM113STATLAB/MED110CLEANHOLDING107BUILDINGMAINTENANCETOILET/SHOWER138APoSPATIENTTOILET105CSHAREDPROVIDEROFFICE104STAFFTOILET103STAFFBREAK102EXAM112RECEPTION101BVISITORTOILET101ALOBBY/WAITING101PUBLICTOILET100BEVS109MECHANICAL145CORRIDOR122BS-2BS-3BS-14BS-13BS-4BS-1BS-5BS-8BS-7BS-6BS-9BS-10BS-11BS-12AC-18ASTAIR2ST2-1STAIR1ST1-13241803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:03:45 PMM201FIRST FLOORPIPING PLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIRST FLOOR PLANNGENERAL NOTES:1. SINGLE LINE PIPING SHOWN FOR CLARITY, MULTIPLE PIPES EXIST PER SINGLE LINE PIPE. REFER TO VRF SCHEMATICS FOR NUMBER AND SIZE OF REFRIGERANT PIPING.DRAWING NOTES:(1) SET OF REFRIGERANT PIPING DOWN FROM ACCU-1W ON ROOF. ACCU-1W TO SERVE INDOOR UNITS ON THIS FLOOR.(1) SET OF REFRIGERANT PIPING DOWN FROM ACCU-1N ON ROOF. ACCU-1N TO SERVE INDOOR UNITS ON THIS FLOOR.(1) SET OF REFRIGERANT PIPING DOWN FROM ACCU-1E ON ROOF. ACCU-1E TO SERVE INDOOR UNITS ON THIS FLOOR.(1) SET OF REFRIGERANT PIPING DOWN FROM ACCU-1S ON ROOF. ACCU-1S TO SERVE INDOOR UNITS ON THIS FLOOR.1234REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223RESPITE/LACTATION240STAFFTOILET237CORRIDOR232DFC-18BDFC-15GDFC-05JDFC-15NDFC-18CDF C -2 4 C DF C -3 0 C DFC-07ODFC-05KDF C -1 5HDFC-05LDF C -0 5M DF C -0 5 N DFC-12DDFC-09EDFC-09FDFC-12EDFC-09HDFC-24DRESPITE/MEDITATION241CIRCULATION228WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202NURSE214PHYSICIANOFFICE/DICTATION213LAB221EDUCATION/CONFERENCE234IT/ELEC243DFC-09GEXAM212EXAM211EXAM210MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204SHAREDCLERICALOFFICE203EXAM216EXAM215MULTIPURPOSE/ACTIVITY235OFFICE238DFC-36ADFC-24FTELMED233DFC-15MSTAFFBREAK242STAFFTOILET236RESPITE/LACTATION239DENTALOFFICE230TRIAGENURSEALCOVE207AAC-18DCIRCULATION207BS-18BS-19BS-20BS-21BS-17BS-16BS-152S2W2N2EBS-22WALKINGTRACK200STAIRST2-2STAIR1ST1-23241803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:03:54 PMM202SECONDFLOOR PIPINGPLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1SECOND FLOOR PLANNGENERAL NOTES:1. SINGLE LINE PIPING SHOWN FOR CLARITY, MULTIPLE PIPES EXIST PER SINGLE LINE PIPE. REFER TO VRF SCHEMATICS FOR NUMBER AND SIZE OF REFRIGERANT PIPING.DRAWING NOTES:(2) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1W, ACCU-2W ON ROOF, (1) SET DOWN TO INDOOR UNITS ON FLOOR BELOW. ACCU-2W TO SERVE INDOOR UNITS ON THIS FLOOR.(2) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1N, ACCU-2N ON ROOF, (1) SET DOWN TO INDOOR UNITS ON FLOOR BELOW. ACCU-2N TO SERVE INDOOR UNITS ON THIS FLOOR.(2) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1E, ACCU-2E ON ROOF, (1) SET DOWN TO INDOOR UNITS ON FLOOR BELOW. ACCU-2E TO SERVE INDOOR UNITS ON THIS FLOOR.(2) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1S, ACCU-2S ON ROOF, (1) SET DOWN TO INDOOR UNITS ON FLOOR BELOW. ACCU-2S TO SERVE INDOOR UNITS ON THIS FLOOR.1234REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8ELEC/DATA323EXAM/CONSULT321EXAM/CONSULT313EXAM/CONSULT320EXAM/CONSULT314EXAM/CONSULT319EXAM/CONSULT315EXAM/CONSULT318EXAM/CONSULT316PROVIDEROFFICE317FTRIAGENURSE324SPECIALTYEXAM/TREATMENT326PATIENTTOILET327EXAM/CONSULT328EXAM/CONSULT329PROVIDEROFFICE339ANURSEWORK339EXAM/CONSULT327TRIAGENURSE339BSPECIALTYEXAM/TREATMENT/TELEMED335LAB334PATIENTTOILET335AEXAM/CONSULT331SPECIMENCOLLECTION333GUESTWAITING/CIRCULATION300REGISTRATION301PUBLICTOILET300BPUBLICTOILET300ASTAFFTOILET325PATIENTTOILET326AEXAM/CONSULT322CENTRALCLEANWORK312CENTRALSOILEDWORK311EXAM/CONSULT309EXAM/CONSULT308EXAM/CONSULT307EXAM/CONSULT306PROVIDEROFFICE317ASTAFFBREAKAREA305PATIENTTOILET302OFFICEMANAGER301ASTAFFTOILET305ALABDRAW332SPECIALTYEXAM/TREATMENT303PATIENTVITALSALCOVE310EVS330AC-18EDFC-07LDFC-05ARDFC-05ASDFC-18JDFC-05ATDFC-05AVDFC-05AUDFC-12PDFC-05AWDFC-12QDFC-18KDFC-36CDFC-18LDFC-05AXDFC-05AYDFC-15ODFC-05AZDFC-09ODFC-05BCDFC-05BDDFC-05BEDFC-05BGDFC-05BHDFC-05BIDFC-09QDFC-05BJDFC-07MDFC-09PNURSEWORKAREA317BPATIENTTOILET336NURSEWORKAREA317EDFC-05BFDFC-05BBDFC-05BADFC-18IEXAM/CONSULT328STAFFCIRCULATION317BS-29BS-30BS-24BS-23BS-25BS-27BS-283W3N3EBS-263SSTAIR1ST1-3STAIR2ST2-3AC-24C3241803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:04:05 PMM203THIRD FLOORPIPING PLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1THIRD FLOOR PLANNGENERAL NOTES:1. SINGLE LINE PIPING SHOWN FOR CLARITY, MULTIPLE PIPES EXIST PER SINGLE LINE PIPE. REFER TO VRF SCHEMATICS FOR NUMBER AND SIZE OF REFRIGERANT PIPING.DRAWING NOTES:(3) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1W, ACCU-2W, ACCU-3W ON ROOF, (2) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW. ACCU-3W TO SERVE INDOOR UNITS ON THIS FLOOR.(3) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1N, ACCU-2N, ACCU-3N ON ROOF, (2) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW. ACCU-3N TO SERVE INDOOR UNITS ON THIS FLOOR.(3) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1E, ACCU-2E, ACCU-3E ON ROOF, (2) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW. ACCU-3E TO SERVE INDOOR UNITS ON THIS FLOOR.(3) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1S, ACCU-2S, ACCU-3S ON ROOF, (2) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW. ACCU-3S TO SERVE INDOOR UNITS ON THIS FLOOR.1234REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 1234ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414PATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BSTAFFTOILET445EVS439DFC-15IDFC-30BDFC-07EDFC-05ODFC-05AODFC-15JDFC-09IDFC-15KDFC-18EDFC-12FDFC-12GDFC-05QDFC-05RDFC-05SDFC-12HDFC-07FDFC-09JDFC-12SDFC-15LDFC-05TDFC-07HDFC-12JDFC-05PDFC-07IDFC-12KDFC-12LDFC-07PAC-18GAC-18FPROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402WOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418ACIRCULATION412HOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS417DFC-05UDFC-05XPROCEDUREROOM440STORAGE404DFC-12IDFC-07QEQUIPMENTSTORAGE431APUBLICTOILET400ADFC-07NWOMEN'SCIRCULATION407BS-40BS-37BS-33BS-31BS-32BS-394W4N4E4SBS-34BS-35BS-36BS-38BS-41BS-42STAIR1ST1-4RESULTSALCOVE410WOMEN'SSUB-WAIT409STAIR2ST2-41324803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:04:17 PMM204FOURTHFLOOR PIPINGPLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FOURTH FLOOR PLANNGENERAL NOTES:1. SINGLE LINE PIPING SHOWN FOR CLARITY, MULTIPLE PIPES EXIST PER SINGLE LINE PIPE. REFER TO VRF SCHEMATICS FOR NUMBER AND SIZE OF REFRIGERANT PIPING.DRAWING NOTES:(4) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1W, ACCU-2W, ACCU-3W, ACCU-4W ON ROOF, (3) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW. ACCU-4W TO SERVE INDOOR UNITS ON THIS FLOOR.(4) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1N, ACCU-2N, ACCU-3N, ACCU-4N ON ROOF, (3) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW. ACCU-4N TO SERVE INDOOR UNITS ON THIS FLOOR.(4) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1E, ACCU-2E, ACCU-3E, ACCU-4E ON ROOF, (3) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW. ACCU-4E TO SERVE INDOOR UNITS ON THIS FLOOR.(4) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1S, ACCU-2S, ACCU-3S, ACCU-4S ON ROOF, (3) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW. ACCU-4S TO SERVE INDOOR UNITS ON THIS FLOOR.1234REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507EXAM/CONSULT522PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529EXAM/CONSULT531SPECIALTYEXAM/TREATMENT526PATIENTTOILET527PATIENTTOILET526ASTAFFTOILET525STAFFCIRCULATION517CIRCULATION504BBNURSEWORKAREA517BSPECIALTYEXAM/TREATMENT506CIRCULATION517DNURSEWORKAREA517EIT/ELEC523PROVIDEROFFICE517FOFFICEMANAGER502APATIENTTOILET503STAFFBREAKAREA505STAIR3ST3-5PUBLICTOILET501APUBLICTOILET501BELEVA500EAELEVB500EBELEVATORCONTROLROOM500LAB534LABDRAW532SPECIMENCOLLECTION533STAIR1ST1-5PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535EXAM/CONSULT537CENTRALSOILEDWORK511STAFFTOILET505ACIRCULATION504DFC-07JAC-18IDFC-05AMAC-18HEXAM/CONSULT538CIRCULATION504EVS530DFC-07GDFC-18MDFC-05YDFC-05ZDFC-18FTRIAGENURSE539BPATIENTTOILET536DFC-05ABDFC-05AADFC-05ACDFC-12NDFC-18GDFC-36BDFC-18HGUESTWAITING/CIRCULATION501DFC-05ADDFC-15PDFC-09KDFC-09MDFC-05APDFC-09NDFC-05AQEXAM/CONSULT520EXAM/CONSULT519DFC-05ALEXAM/CONSULT513EXAM/CONSULT514EXAM/CONSULT515EXAM/CONSULT516DFC-05AIDFC-05AJDFC-09LPROVIDEROFFICE517ADFC-05AHDFC-05AFDFC-05AGEXAM/CONSULT509EXAM/CONSULT508DFC-05AEDFC-12OEXAM/CONSULT518DFC-05AKDFC-05ANCENTRALCLEANWORK512TRIAGENURSE524PATIENTVITALSALCOVE510STAIRVESTIBULE504A5W5N5EBS-43BS-44BS-45BS-46BS-47BS-48BS-49BS-505SREGISTRATION502STAIR2ST2-5AC-24B12345768803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:04:29 PMM205FIFTH FLOORPIPING PLAN02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIFTH FLOOR PLANNGENERAL NOTES:1. SINGLE LINE PIPING SHOWN FOR CLARITY, MULTIPLE PIPES EXIST PER SINGLE LINE PIPE. REFER TO VRF SCHEMATICS FOR NUMBER AND SIZE OF REFRIGERANT PIPING.DRAWING NOTES:1(1) SET OF REFRIGERANT PIPING DOWN FROM ACCU-5W ON ROOF.(1) SET OF REFRIGERANT PIPING DOWN FROM ACCU-5N ON ROOF.(1) SET OF REFRIGERANT PIPING DOWN FROM ACCU-5E ON ROOF.(1) SET OF REFRIGERANT PIPING DOWN FROM ACCU-5S ON ROOF.(4) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1W, ACCU-2W, ACCU-3W, ACCU-4W ON ROOF, (4) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW.(4) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1N, ACCU-2N, ACCU-3N, ACCU-4N ON ROOF, (4) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW.(4) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1E, ACCU-2E, ACCU-3E, ACCU-4E ON ROOF, (4) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW.(4) SETS OF REFRIGERANT PIPING DOWN FROM ACCU-1S, ACCU-2S, ACCU-3S, ACCU-4S ON ROOF, (4) SETS DOWN TO INDOOR UNITS ON FLOORS BELOW.2345678REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 3/4"7/8 x3/8 x1/2"5/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x3/4"7/8 x3/8 x1/2"1/4 x5/8"3/8 x5/8"3/8 x5/8"3/8 x1/2"1/4 x5/8"3/4 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x5/8"3/4 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 xACCU-1EREYQ96XATJAKHRP25A33T9 KHRP25A22T9BS 5BSQ36TVJADFC-05B120 - ExamFXSQ05TAVJUKHRP25A22T9BS 6BSQ36TVJADFC-05CFXSQ05TAVJUKHRP25A22T9BS 7BSQ36TVJADFC-12R105 CirculationFXSQ12TAVJUBS 8BSQ36TVJADFC-05A106 TriageFXSQ05TAVJUKHRP25A22T9BS 9BSQ36TVJADFC-15EFXSQ15TAVJUKHRP25A22T9BS 10BSQ36TVJADFC-07D105 - Sub WaitingFXSQ07TAVJUKHRP25A22T9BS 11BSQ36TVJADFC-15DFXSQ15TAVJUBS 12BSQ36TVJADFC-12B103 Staff ToiletFXSQ12TAVJUACCU-1NREYQ96XATJABS 4BS6Q54TVJADFC-12AFXSQ12TAVJUBDFC-24A536C - EVSFXSQ24TAVJUCDCF-24BFXSQ24TAVJUDDFC-30AFXSQ30TAVJUEDFC-09R100A - Main LobbyFXSQ09TAVJUFACCU-1SREYQ72XATJAKHRP25A33T9BS 13BS4Q54TVJADFC-05G141 Emergency EquipFXSQ05TAVJUBDFC-05H146 Water servFXSQ05TAVJUCDBS 14BS4Q54TVJADFC-18A138 Supply ChainFXSQ18TAVJUBDFC-05F143 CorrFXSQ05TAVJUCDFC-05D118 ExamFXSQ05TAVJUDDFC-09S119 RadiologyFXSQ09TAVJUACCU-1WREYQ72XATJAKHRP25A33T9BS 3BSQ36TVJADFC-15B123 - WaitingFXSQ15TAVJUKHRP25A22T9BS 2BSQ36TVJADFC-09B126 - LabFXSQ09TAVJUBS 1BS4Q54TVJADFC-07B122 - CorridorFXSQ07TAVJUBDFC-07A127 - Blood DrawFXSQ07TAVJUCDFC-15A137 - Waste HoldingFXSQ15TAVJUDDFC-05BKFXSQ05TAVJU803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:04:39 PMM301VRFSCHEMATIC02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 5/8"3/4 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x5/8"3/4 x3/8 x5/8"3/8 x1/2"1/4 x5/8"3/8 x3/4"7/8 x3/8 x1/2"5/8 x3/8 x5/8"3/8 x3/4"7/8 x3/8 x1/2"5/8 x3/8 x5/8"3/8 x5/8"3/4 x3/8 x3/4"3/8 x1/2"1/4 x5/8"3/8 x1/2"1/4 x5/8"3/8 x1/2"1/4 x5/8"3/8 x3/4"7/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 xACCU-2EREYQ72XATJAKHRP25A33T9BS 21BS6Q54TVJADFC-15H202 Shared ReceptionFXSQ15TAVJUBDFC-05N206 Shared Multi PurposeFXSQ05TAVJUCDFC-09F211 ExamFXSQ09TAVJUDDFC-09E208 Shared Staff BreakFXSQ09TAVJUEDFC-05L204 Multi PurposeFXSQ05TAVJUFDFC-05M203 Shared ClericalFXSQ05TAVJUBS 22BSQ36TVJADFC-12E213 Physicians OfficeFXSQ12TAVJUACCU-2NREYQ72XATJABS 20BS4Q54TVJADFC-24CFXSQ24TAVJUBDFC-18CFXSQ18TAVJUCDFC-30CFXSQ30TAVJUDACCU-2SREYQ96XATJAKHRP25A33T9BS 15BS4Q54TVJADFC-24F223 Open Exterior SpaceFXSQ24TAVJUBCDKHRP25A33T9BS 16BS4Q54TVJADFC-36A223 Open Interior SpaceFXSQ36TAVJUBCDBS 3BSQ60TVJAKHRP26A22T9DFC-09HFXSQ09TAVJUKHRP26A22T9DFC-09GFXSQ09TAVJUKHRP26A22T9DFC-12DFXSQ12TAVJUDFC-24D228 DentalFXSQ24TAVJUACCU-2WREYQ96XATJAKHRP25A33T9BS 19BS4Q54TVJADFC-15N234 EducationFXSQ15TAVJUBDFC-05K233 TelmedFXSQ05TAVJUCDFC-15GFXSQ15TAVJUDBS 18BS4Q54TVJADFC-07O232 CorrFXSQ07TAVJUBDFC-18B242 Staff BreakFXSQ18TAVJUCDFC-15M236 Staff ToiletFXSQ15TAVJUDDFC-05J238 OfficeFXSQ05TAVJU803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:04:49 PMM302VRFSCHEMATIC02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 5/8"3/4 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x3/4"7/8 x3/8 x3/4"7/8 x3/8 x1/2"1/4 x1/2"1/4 x5/8"3/8 x1/2"5/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x5/8"3/8 x1/2"1/4 x5/8"3/8 x1/2"1/4 x1/2"1/4 x5/8"3/4 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x5/8"3/4 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 xACCU-3EREYQ72XATJABS 28BS8Q54TVJADFC-05BDFXSQ05TAVJUBDFC-05BEFXSQ05TAVJUCDFC-05BFFXSQ05TAVJUDDFC-05BCFXSQ05TAVJUEDFC-09OFXSQ09TAVJUFDFC-05BAFXSQ05TAVJUGDFC-05BBFXSQ05TAVJUHDFC-12QFXSQ12TAVJUACCU-3NREYQ96XATJAKHRP25A33T9BS 25BS4Q54TVJADFC-18KFXSQ18TAVJUBDFC-18LFXSQ18TAVJUCDFC-36CFXSQ36TAVJUDKHRP25A22T9BS 26BSQ36TVJADFC-05AZFXSQ05TAVJUBS 27BSQ36TVJAKHRP26A22T9DFC-05AYFXSQ05TAVJUKHRP26A22T9DFC-15OFXSQ15TAVJUDFC-05AXFXSQ05TAVJUACCU-3SREYQ72XATJAKHRP25A33T9BS 29BS4Q54TVJADFC-05BJFXSQ05TAVJUBDFC-07MFXSQ07TAVJUCDFC-09PFXSQ09TAVJUDDFC-18IFXSQ18TAVJUBS 30BS4Q54TVJADFC-09QFXSQ09TAVJUBDFC-05BIFXSQ05TAVJUCDFC-05BHFXSQ05TAVJUDDFC-05BGFXSQ05TAVJUACCU-3WREYQ72XATJAKHRP25A33T9BS 23BS4Q54TVJADFC-12PFXSQ12TAVJUBDFC-05AUFXSQ05TAVJUCDFC-05AVFXSQ05TAVJUDBS 24BS6Q54TVJADFC-05ATFXSQ05TAVJUBDFC-18JFXSQ18TAVJUCDFC-05AWFXSQ05TAVJUDDFC-05ASFXSQ05TAVJUEDFC-05ARFXSQ05TAVJUFDFC-07LFXSQ07TAVJU803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:04:59 PMM303VRFSCHEMATIC02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 3/4"7/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x3/4"7/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x5/8"3/4 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x5/8"3/4 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x5/8"3/8 x1/2"1/4 x5/8"3/8 x1/2"1/4 x1/2"1/4 x3/4"7/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x3/4"7/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x3/4"7/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x3/4"7/8 x3/8 x1/2"5/8 x3/8 x5/8"3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 xACCU-4EREYQ96XATJAKHRP25A33T9BS 36BSQ36TVJADFC-09JFXSQ09TAVJUKHRP25A33T9BS 35BSQ36TVJADFC-07HFXSQ07TAVJUKHRP25A22T9BS 37BS4Q54TVJADFC-05TFXSQ05TAVJUBDFC-05RFXSQ05TAVJUCDFC-05QFXSQ05TAVJUDDFC-05SFXSQ05TAVJUBS 38BS4Q54TVJADFC-15LFXSQ15TAVJUBDFC-12IFXSQ12TAVJUCDFC-12HFXSQ12TAVJUDDFC-07FFXSQ07TAVJUACCU-4NREYQ72XATJAKHRP25A33T9BS 34BSQ36TVJADFC-15KFXSQ15TAVJUBS 33BSQ60TVJAKHRP26A22T9DFC-18EFXSQ18TAVJUKHRP26A22T9DFC-12FFXSQ12TAVJUDFC-12GFXSQ12TAVJUACCU-4SREYQ96XATJAKHRP25A33T9BS 41BSQ36TVJADFC-05XFXSQ05TAVJUKHRP25A33T9BS 42BSQ36TVJADFC-07PFXSQ07TAVJUKHRP25A33T9BS 39BS4Q54TVJADFC-07NFXSQ07TAVJUBDFC-07IFXSQ07TAVJUCDFC-07PFXSQ07TAVJUDDFC-12JFXSQ12TAVJUBS 40BS4Q54TVJADFC-12KFXSQ12TAVJUBDFC-12LFXSQ12TAVJUCDFC-12SFXSQ12TAVJUDDFC-05UFXSQ05TAVJUACCU-4WREYQ96XATJAKHRP25A33T9BS 31BS4Q54TVJADFC-30BFXSQ30TAVJUBDFC-07EFXSQ07TAVJUCDFC-09IFXSQ09TAVJUDDFC-05OFXSQ05TAVJUBS 32BS4Q54TVJADFC-15JFXSQ15TAVJUBDFC-15IFXSQ15TAVJUCDFC-05PFXSQ05TAVJUDDFC-05AOFXSQ05TAVJU803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:06 PMM304VRFSCHEMATIC02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 5/8"3/4 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x3/4"7/8 x3/8 x3/4"7/8 x3/8 x1/2"1/4 x1/2"1/4 x5/8"3/8 x1/2"5/8 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"5/8 x3/8 x5/8"3/8 x1/2"1/4 x5/8"3/8 x1/2"1/4 x5/8"3/8 x1/2"1/4 x1/2"1/4 x5/8"3/4 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x5/8"3/4 x3/8 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"5/8 x3/8 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 x1/2"1/4 xACCU-5EREYQ72XATJABS 47BS8Q54TVJADFC-12OFXSQ12TAVJUBDFC-05AQFXSQ05TAVJUCDFC-05AIFXSQ05TAVJUDDFC-05AJFXSQ05TAVJUEDFC-05AHFXSQ05TAVJUFDFC-09LFXSQ09TAVJUGDFC-005AFFXSQ05TAVJUHDFC-05AGFXSQ05TAVJUACCU-5NREYQ96XATJAKHRP25A33T9BS 45BS4Q54TVJADCF-18GFXSQ18TAVJUBDFC-18HFXSQ18TAVJUCDFC-36BFXSQ36TAVJUDKHRP25A22T9BS 46BSQ36TVJADFC-05AEFXSQ05TAVJUBS 48BSQ60TVJAKHRP26A22T9DFC-07GFXSQ07TAVJUKHRP26A22T9DFC-05ADFXSQ05TAVJUKHRP26A22T9DFC-18MFXSQ18TAVJUDFC-15PFXSQ15TAVJUACCU-5SREYQ72XATJAKHRP25A33T9BS 50BS4Q54TVJADFC-09NFXSQ09TAVJUBDFC-05AMFXSQ05TAVJUCDFC-05ALFXSQ05TAVJUDDFC-05AKFXSQ05TAVJUBS 49BS4Q54TVJADFC-05ANFXSQ05TAVJUBDFC-09MFXSQ09TAVJUCDFC-09KFXSQ09TAVJUDACCU-5WREYQ72XATJAKHRP25A33T9BS 44BS4Q54TVJADFC-12NFXSQ12TAVJUBDFC-05ABFXSQ05TAVJUCDFC-05ACFXSQ05TAVJUDBS 43BS6Q54TVJADFC-18FFXSQ18TAVJUBDFC-05AAFXSQ05TAVJUCDFC-05ZFXSQ05TAVJUDDFC-07JFXSQ07TAVJUEDFC-05YFXSQ05TAVJUFDFC-05APFXSQ05TAVJU803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:21 PMM305VRFSCHEMATIC02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:22 PMM401SCHEDULES02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGVRF SYSTEM SCHEDULE - INDOOR UNITSTAG LOCATION SERVICETYPECFME.S.P. (in.WG)TMBH SMBH HEATING MBHELECTRICAL DATADESIGN EQUIPMENTVOLTS PH MCA MOCPDDFC-05_ MULTIPLE MULTIPLE DUCTED CONCEALED 280 0.60 5.04.76.8 208 1 0.80 A 15DAIKIN FXSQ05TAVJUDFC-07_ MULTIPLE MULTIPLE DUCTED CONCEALED 280 0.60 7.05.88.9 208 1 0.80 A 15DAIKIN FXSQ07TAVJUDFC-09_ MULTIPLE MULTIPLE DUCTED CONCEALED 320 0.60 9.07.010.9 208 1 0.80 A 15DAIKIN FXSQ09TAVJUDFC-12_ MULTIPLE MULTIPLE DUCTED CONCEALED 335 0.60 12.0 9.713.9 208 1 0.80 A 15DAIKIN FXSQ12TAVJUDFC-15_ MULTIPLE MULTIPLE DUCTED CONCEALED 530 0.60 15.0 11.317.7 208 1 1.40 A 15DAIKIN FXSQ15TAVJUDFC-18_ MULTIPLE MULTIPLE DUCTED CONCEALED 600 0.60 18.0 13.620.8 208 1 1.60 A 15DAIKIN FXSQ18TAVJUDFC-24_ MULTIPLE MULTIPLE DUCTED CONCEALED 740 0.60 24.0 17.130.0 208 1 1.80 A 15DAIKIN FXSQ24TAVJUDFC-30_ MULTIPLE MULTIPLE DUCTED CONCEALED 810 0.60 30.0 22.635.1 208 1 1.80 A 15DAIKIN FXSQ30TAVJUDFC-36_ MULTIPLE MULTIPLE DUCTED CONCEALED 1130 0.60 36.0 25.741.3 208 12.50 A 15DAIKIN FXSQ36TAVJUVRF SYSTEM SCHEDULE - OUTDOOR UNITSTAGLOCATIONSERVICECOOLINGAMBIENT TEMP.COOLINGMBHHEATINGAMBIENT TEMPHEATING MBHELECTRICAL DATAMCA MOCPDDESIGN EQUIPMENTVOLTAGE PHACCU-1EROOF1ST FLOOR EAST89 °F96.0-10 °F108.0208 3 38.145DAIKIN REYQ96XATJAACCU-1NROOF1ST FLOOR NORTH89 °F96.0-10 °F108.0208 3 38.145DAIKIN REYQ96XATJAACCU-1SROOF1ST FLOOR SOUTH89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-1WROOF1ST FLOOR WEST89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-2EROOF2ND FLOOR EAST89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-2NROOF2ND FLOOR NORTH89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-2SROOF2ND FLOOR SOUTH89 °F96.0-10 °F108.0208 3 38.145DAIKIN REYQ96XATJAACCU-2WROOF2ND FLOOR WEST89 °F96.0-10 °F108.0208 3 38.145DAIKIN REYQ96XATJAACCU-3EROOF3RD FLOOR EAST89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-3NROOF3RD FLOOR NORTH89 °F96.0-10 °F108.0208 3 38.145DAIKIN REYQ96XATJAACCU-3SROOF3RD FLOOR SOUTH89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-3WROOF3RD FLOOR WEST89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-4EROOF4TH FLOOR EAST89 °F96.0-10 °F108.0208 3 38.145DAIKIN REYQ96XATJAACCU-4NROOF4TH FLOOR NORTH89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-4SROOF4TH FLOOR SOUTH89 °F96.0-10 °F108.0208 3 38.145DAIKIN REYQ96XATJAACCU-4WROOF4TH FLOOR WEST89 °F96.0-10 °F108.0208 3 38.145DAIKIN REYQ96XATJAACCU-5EROOF5TH FLOOR EAST89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-5NROOF5TH FLOOR NORTH89 °F96.0-10 °F108.0208 3 38.145DAIKIN REYQ96XATJAACCU-5SROOF5TH FLOOR SOUTH89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJAACCU-5WROOF5TH FLOOR WEST89 °F72.0-10 °F81.0208 3 38.145DAIKIN REYQ72XATJANOTES:1. PROVIDE ALL OUTDOOR UNITS ON EQUIPMENT SUPPORT RAILS, RAILS BY OTHERS.2. ELECTRICAL CONTRACTOR TO PROVIDE A SINGLE 120V POWER CONNECTION FOR ALL BRANCH SELECTOR BOXES SHOWN ON DRAWINGS.3. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECT SWITCH FOR ALL OUTDOOR UNITS.4. PROVIDE DAIKIN VRF SYSTEM TOUCHSCREEN HEAD END CONTROLLER, I-TOUCH MANAGER AT LOCATION SHOWN ON M101. INTERLOCK ENTIRE VRF SYSTEM AND DOAS UNITS TO I-TOUCH CONTROLLER.NOTES:1. PROVIDE VARIABLE REFRIGERANT FLOW CONDENSING UNIT CONNECTED TO MULTIPLE INTERIOR UNITS PER MANUFACTURER'S REQUIREMENTS, INCLUDING ALL REQUIRED CONTROLS.2. PROVIDE 3-PIPE REFRIGERANT PIPING SYSTEM FOR SIMULTANEOUS HEATING AND COOLING AVAILABILITY FOR AIR HANDLING UNITS PER MANUFACTURER'S REFRIGERANT PIPING REQUIREMENTS.3. PROVIDE APPROPRIATE PIPING MANIFOLD OR KIT AS REQUIRED FOR EACH INDOOR UNIT.4. ALL INDOOR UNITS SHALL HAVE INTEGRAL CONDENSATE DRAIN PUMP WITH A SINGLE POINT ELECTRICAL CONTECTION.5. PROVIDE WIRED REMOTE CONTROLLERS AT ALL LOCATIONS. WIRELESS REMOTE CONTROLLERS SHALL NOT BE ACCEPTABLE.6. PROVIDE ALL DUCTED INDOOR UNITS WITH A SINGLE RETURN REGISTER SERVING A SINGLE INDOOR UNIT WITH A FILTERED RETURN REGISTER WITH A 2" MERV 8 FILTER.7. PROVIDE ALL DUCTED INDOOR UNITS WITH MULTIPLE RETURN REGISTERS SERVING A SINGLE INDOOR UNIT WITH ACCESSIBLE FILTER BOXES, CONTRACTOR TO FIELD FABRICATE AND INSTALL 2" MERV 8 FILTER RACK AT FAN COIL RETURN AIR INTAKE. FILTER BOX TO BE FABRICATED TO STANDARD FILTER DIMENSIONS. CONTRACTOR TO SHOW SIDE OR BOTTOM ACCESS PER UNIT ON COORDINATION DRAWING SUBMITTAL.8. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECT SWITCH FOR ALL INDOOR UNITS.9. PROVIDE DAIKIN VRF SYSTEM TOUCHSCREEN HEAD END CONTROLLER, I-TOUCH MANAGER AT LOCATION SHOWN ON M101. INTERLOCK ENTIRE VRF SYSTEM AND DOAS UNITS TO I-TOUCH CONTROLLER.ROOFTOP HEAT RECOVERY UNIT SCHEDULE - DX HEATPUMP WITH ELECTRIC BACKUPTAG LOCATIONSERVICESUPPLY FANEXHAUST FANMIN OA EERCOOLING - HXSUMMERWINTERHEATING - ELECTRICELECTRICAL DATADESIGN EQUIPMENTCFM E.S.P. (in. wg) HP CFM E.S.P. (in. wg.) HPTMBH SMBH ROWS EAT db EAT wb LAT db LAT wb EAT db EAT wb LAT db LAT wb KW MBH STAGES LAT VOLT PH MCA MOCPDDOAS-1 ROOF5TH FLOOR VENTILATION 1945 1.25 4 1250 1.00 2.3 1945 12.6 85.756.9 3 89 °F 74 °F 80 °F 67 °F 0 °F -1 °F 41 °F 33 °F 18.0 61.4 SCR 70 °F 2083 103.80 A 110.00 ADAIKIN DPS007ADOAS-2 ROOF 1ST - 4TH FLOOR VENTILATION 4150 1.25 8 3375 1.00 4 4150 10.7174.7 118.3 6 89 °F 74 °F 80 °F 67 °F 0 °F -1 °F 38 °F 30 °F 54.0 184.3 SCR 78.6 208 3 229.10 A 250.00 ADAIKIN DPS015ADOAS-3 ROOF 1ST - 4TH FLOOR VENTILATION 4565 1.25 8 3160 1.00 4 4565 10.7181.1 125.6 6 89 °F 74 °F 81 °F 69 °F 0 °F -1 °F 34 °F 27 °F 54.0 184.3 SCR 71 208 3 229.10 A 250.00 ADAIKIN DPS015ANOTES:1. PROVIDE ALL DOAS'S WITH MERV 8 PRE-FILTERS, MERV-13 FINAL FILTERS, ECM FAN MOTORS, HEAT RECOVERY SECTION, MODULATING COMPRESSORS, SCR CONTROLLED ELECTRIC HEAT, HOT GAS REHEAT WITH DEHUMIDIFICATION CONTROL, SINGLE POINT POWER CONNECTION, PACKAGED DISCONNECT AND STARTER, DIRTY FILTER SWITCH AND 14" WIND RATED ROOF CURB.2. FOR ALL DOAS'S WITH MORE THAN 2000 CFM, EC SHALL FURNISH SUPPLY SIDE DUCT SMOKE DETECTOR, MC SHALL INSTALL SUPPLY SIDE DUCT SMOKE DETECTOR.3. PROVIDE 1" CONDENSATE PIPING FROM ALL DOAS'S TO THE NEAREST ROOF DRAIN AND TERMINATE INDIRECTLY.4. PROVIDE DAIKIN VRF SYSTEM TOUCHSCREEN HEAD END CONTROLLER, I-TOUCH MANAGER AT LOCATION SHOWN ON M101. INTERLOCK ENTIRE VRF SYSTEM AND DOAS UNITS TO I-TOUCH CONTROLLER.5. PRIMARY HEATING IS TO BE THRU THE AIR SOURCE HEAT PUMP, ELECTRIC HEAT IS FOR TRIMMING TO 70°F LAT OFF UNIT ONLY. AIR SOURCE HEAT PUMP MODE IS EXPECTED TO BE THE PRIMARY HEATING SOURCE DOWN TO 10°F OAT WHICH IS WHEN THE LAT OF THE WHEEL IS EXPECTED TO DIP BELOW 43°F.FAN SCHEDULETAG LOCATION SERVICE CFME.S.P.(in. wg)BLADETYPEFANRPMDRIVE TYPE SONESELECTRICAL DATADESIGN EQUIPMENTHP VOLT PH FLA STARTERBF-1_ MULTIPLE HWH-1 300 0.40 BC 2466 DIRECT, ECM 0.1 208 1 0.50 A BY EC FANTECH FG8ECEF-1560 ROOF SOILED LINEN 1560 1.00 BI 1371 BELT 13.4 0.75 120 1 13.80 A BY EC GREENHECK CUBE-141NOTES: 1. EC SHALL PROVIDE STARTERS AND DISCONNECTS.2. PROVIDE ROOF MOUNTED EXHAUST FANS WITH HINGED, WIND RATED CURBS.3. PROVIDE BF-1 WITH ECM MOTOR AND INTERLOCK WITH OPERATION OF HWH-1 SERVED, INTERLOCK BY MC. REGISTER, GRILLE & DIFFUSER SCHEDULETAGTYPEMATERIAL FINISH/COLOR DAMPER DESIGN EQUIPMENT1SUPPLYSTEEL / ALUMINUM BY ARCH Yes TITUS OMNI / OMNI-AA2SUPPLYSTEEL / ALUMINUM BY ARCH Yes TITUS 272RL / 272FL3SUPPLYALUMINUMBY ARCH YesTITUS ML-39A RETURN / EXHAUST STEEL / ALUMINUM BY ARCH Yes TITUS 350RL / 350FLB RETURN / EXHAUST STEEL / ALUMINUM BY ARCH YesTITUS 350RLF1C RETURN / EXHAUSTALUMINUMBY ARCH YesTITUS MLR-39NOTES: 1. PROVIDE ALL TYPE 1, 2, A & B DIFFUSERS AND REGISTERS WITH OPPOSED BLADE DAMPERS.2. PROVIDE ALL DUCTED INDOOR UNITS WITH A SINGLE TYPE B RETURN REGISTER SERVING A SINGLE INDOOR UNIT WITH A FILTERED RETURN REGISTER WITH A 1" MERV 8 FILTER.MINI-SPLIT SYSTEM - OUTDOOR UNITTAG LOCATIONPAIRED INDOORUNITSSEER LOW AMBIENTELECTRICAL DATADESIGN EQUIPMENTVOLTS PH MCA MOCPDCU-18_ ROOF AC-18_ 17 Yes 208 1 16.50 A 20.00 A DAIKIN RZR18TAVJUACU-24A ROOF AC-24A 17 Yes 208 1 16.20 A 20.00 A DAIKIN RXB24AXVJUCU-48A ROOF AC-24B,24C 17 Yes 208 1 33.20 A 35.00 A DAIKIN 5MXS48TVJUMINI-SPLIT SYSTEM - INDOOR UNITTAG LOCATION CFMMBHSMBH HEATING MBHELECTRICAL DATADESIGN EQUIPMENTVOLTAGE PHASE MCA MOCPDAC-18_ MULTIPLE 50018.013.720810.50 A 15.00 A DAIKIN FAQ18TAVJUAC-24_ MULTIPLE 55523.516.525.320810.24 A 0.00 A DAIKIN FTXB24AXVJUCABINET UNIT HEATER SCHEDULE - ELECTRICTAG MOUNTING CFMHEATING ELECTRICAL DATADESIGN EQUIPMENTMBH KW EAT LAT AMPS VOLT PHCUH-1_ RECESSED 45 5.1 1.5 45 90 12.5 120 1 QMARK HT1502SSNOTES:1. MC SHALL PROVIDE DISCONNECT AND LINE VOLTAGE THERMOSTAT.2. REVIEW ARCHITECTURAL PLANS FOR WALL TYPES, PROVIDE SURFACE WALL MOUNT FRAME AS REQUIRED.NOTES:1. PROVIDE EACH INDOOR UNIT WITH CONDENSATE PUMP.2. PROVIDE SECONDARY CONDENSATE DETECTION TO SHUT DOWN UNIT UPON DETECTION AND PROVIDE ALARM IN DDC SYSTEM.3. EC TO PROVIDE DISCONNECTS AND STARTERS.NOTES:1. PROVIDE EACH OUTDOOR UNIT WITH LOW AMBIENT CAPACITY AND WIND BAFFLES. 2. PROVIDE OUTDOOR UNITS ON ROOF MOUNTED SUPPORT RACK, SUPPORT RACK BY OTHERS.3. EC TO PROVIDE DISCONNECTS AND STARTERS.NOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE MECHANICAL SCOPE. PIPING, SEALANT AND INSULATION MATERIAL, EQUIPMENT EFFICIENCIES, SPACE PRESSURIZATION REQUIREMENTS, INDOOR AIR QUAILITY REQUIREMENTS, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 230800 AND 019113 FOR COMMISSIONING REQUIREMENTS.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:25 PMM402OUTSIDE AIRMATRIX02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:27 PMM403OUTSIDE AIRMATRIX02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:29 PMM404OUTSIDE AIRMATRIX02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:31 PMM405OUTSIDE AIRMATRIX02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:34 PMM406OUTSIDE AIRMATRIX02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 BOLT RTU FROM INSIDE TO THE CURBWITH 1/2" BOLTS ON 16" CENTERSSCREW HURRICANE STRAPTO ROOF CURB WITHMINIMUM (2) #12 TEKSCREWS.11/2" 18 OR 20 GAUGESTRAP ON 16" CENTERSECURE ROOF CURB TOROOF PER MANUFACTURER'SRECOMMENDATIONS ANDSTRUCTURAL DRAWINGS TOMEET WIND LOADINGREQUIREMENTS.LOOP HURRICANE STRAPTHROUGH STRUCTURE. SEEARCHITECTURAL ANDSTRUCTURAL DRAWINGS FOREXACT ROOF CONSTRUCTION.ROOF TOP UNITDISCONNECT AND FUSESROOF CURBPOWER ENTRY THROUGH BASE OR SIDE OF UNITCONDENSATE DRAIN WITH TRAPPIPE TO NEAREST ROOF DRAINOUTDOOR AIR INTAKEINSTALLATION SEQUENCE1. FOLLOW ALL MANUFACTURER'S INSTALLATIONINSTRUCTIONS.2. APPLY CONSTRUCTION ADHESIVE TO BOTTOM OFALL CURB MEMBERS, SET CURB, LEVEL ANDFASTEN TO DECK.3. CUT SUPPLY AND RETURN DUCT OPENINGSTHROUGH ROOF DECK. DO NOT REMOVE DECKUNDER UNIT.4. APPLY MONO CAULK TO TOP OF ALL CURBMEMBERS, SET HVAC UNIT.5. INSTALL CONDENSATE DRAIN AND MAKE UTILITYCONNECTIONS.RETURN AIR OPENINGSUPPLY AIR OPENINGAAROOF MOUNTING FRAMEFILL CAVITY WITH SOUNDBOARD INSULATIONPACKAGE UNITWOOD NAILER BY MANUFACTURERCOUNTER FLASHINGRIGID INSULATIONROOF MEMBRANEFRAME SECTION A-A14" MINIMUMNOTES:1. G.C. TO CUT BACK INSULATION AND PROVIDE FLASHING. LOCATION, SETTINGS AND SECURING OF CURB BY HVAC.2. PROVIDE SHIMS WHERE REQUIRED TO LEVEL SUPPORT LENGTH OF SUPPORTS AS CALLED FOR. PROVIDE BLOCKING.3. BENEATH SUPPORTS IN FLUTES OF METAL DECKS.1/2" PRESSURE TREATEDPLYWOOD OVER OPENINGCOVERED WITH MIN. 2"THICKNESS OF HOTPOURED ROOF PITCH1-1/2" x 1-1/2" ANGLES FASTENEDTO EACH SIDE OF CURB AT 8" O.C.,MIN TWO FASTENERS PER SIDEROOF CURB WITHHOOD SCREWED TONAILER STRIPSSHEET METALFASTENERS, 8" O.C. MAX,MIN OF TWO FASTENERSPER SIDEHOOD OPENINGAT 45° ANGLEINSULATEDREFRIGERANTPIPE2" PIPE SUPPORT COLUMNINSULATION4" x 4" x 1/4" THICK STEELPLATE ANCHORED TOROOF DECKROOF DECKNOTES (PIPE SUPPORTS)1 ALL FASTENING HARDWARE SHALL BE STAINLESS STEEL.2 SUPPORT FRAMES SHALL BE WELDED ALUMINUM.3 ALL CONSTRUCTION TO MEET ALUMINUM ASSOCIATION SPECS.4 PIPING SHALL BE SLOPED TOWARD THE CONDENSING UNITS.ROOF DECKPROVIDE FLASHING PER ROOFINGSYSTEMMANUFACTURER'S INSTRUCTIONS.ASDFASDFVANES WELDEDVANE RUNNER ASSEMBLYOVER 2000 FPMEQUALMINIMUM45°45°MINIMUM3"'W'3"'W'EQUAL45°45°ACEBELBOW CHECKASSEMBLY TOBOLT VANETO RUNNERVANES WELDEDVANE RUNNER ASSEMBLYRUNNERGA. VANEMINIMUM 24ASSEMBLYVANE RUNNERUP TO 2000 FPMTO RUNNERVANES WELDEDELBOW CHECKASSEMBLY TOBOLT VANEDDTO CHANNEL19" DOVERDIM.UNDER2 1/8"1 1/8"2 7/8"3 1/4"2 1/4"6 3/8"4 1/4" R2 1/4" REDCBA1" R2" R'W'24 GA.VANES MINIMUMDUCTSHIGH VELOCITYCHANNEL FORRUNNERGA. VANEMINIMUM 2424 GA.RUNNER MINIMUM18 GA. FORMEDPROVIDE FLEX CONNECTORAT DUCT & ELECTRICALCONNECTIONS (TYPICAL)ROOF CURB PER RTUMANUFACTURER'SRECOMMENDATIONS TOMEET WIND LOADREQUIREMENTS.ROOF REFER TOARCH. DWGS.SUPPLY DUCTOUTSIDE AIRINTAKEMINIMUM 14" ROOFCURB ABOVEINSULATIONRETURN DUCTFILL INSIDE OF CURB W/SOUND BATT INSULATION1. PIPE CONDENSATE FROM UNIT USING CONNECTION SIZE (1-1/2"MIN.) TO NEAREST ROOF DRAIN. PROVIDE "P" TRAP AT UNIT. SEECONDENSATE DRAIN DETAIL.2.SEE STRUCTURAL DOCUMENTS FOR ANCHORING DETAILS.VOLUME DAMPERDUCT MOUNTEDDAMPERVOLUMEINTEGRALREGISTERWIDTH EQUAL TO DUCTPLENUM BOX LENGTH ANDAS SPECIFIED ON DRAWINGSROUND OR RECTANGULARCONNECTION SIZE12" MINCEILING WITH (1) 90° BENDNOTE: FLEX SHALL BE 4'-0" MAXIMUMELBOW SUPPORT FOR FLEXVDOR JOISTDECK, BEAM,'B'SLOPE: 1"/4'TO SUITCONDITIONAIR GAP = MINIMUM OF 2" OR 2 PIPEDIAMETERS WHICHEVER IS GREATER.FINISHED FLOOROR ROOFFLOOR DRAIN (BY P. C.)'C'=2" (MIN.)'B'=EQUAL TO THE FAN TOTAL STATIC PRESSURE'A'=EQUAL TO HALF THE FAN TOTAL STATIC PRESSURE + 1" (MIN.)180° BENDI.P.S. TO COPPER ADAPTER'A'NOTE:1. PROVIDE ROOF MOUNTED EQUIPMENT WITH TRAP AS SHOWN, PIPE TO NEAREST ROOF DRAINAND TERMINATE INDIRECTLY.2. DRAIN LINE SHALL BE INSULATED.3. COORDINATE EQUIPMENT PAD HEIGHT WITH REQUIREMENT FOR FLOOR DRAIN CONNECTION TOACHIEVE REQUIRED HEIGHT FOR TRAP INSTALLATION AS SHOWN. PAD AND/OR EQUIPMENT RAILHEIGHTS REQUIRED MAY BE IN EXCESS OF MINIMUM HEIGHTS SPECIFIED INOTHER SECTIONS OF THECONTRACT DOCUMENTS.4. CONDENSATE DRAINS FOR ALL ROOF MOUNTED EQUIPMENT AND EQUIPMENT PROVIDED INMECHANICAL ROOMS SHALL BE PROVIDED BY THIS CONTRACT. CONDENSATE DRAINS FOR TERMINALHVAC UNITS SHALL BE PROVIDED BY P.C.DRAIN PANPLUG'C'CONTINUOUS ANGLE 1 1/2 x 1 1/2 , 12 GA. (UP TO 48" WIDE DUCT), 2 x 2, 12 GA. (49" TO 72" DUCT), FASTENTO SLEEVE ONLYIN LIEU OF DOORTHAN THICKNESS OF WALLTHROUGH WALL 12" LONGER14 GAUGE SLEEVEDAMPERSMOKESECURED WITH WING NUTSFLANGED, GASKETED ANDREMOVABLE DUCT SECTION,WIDE, PROVIDE 24" LONGIF DUCT IS LESS THAN 14"MINIMUM SIZE 16" x 12".ACCESS DOOR:RECTANGULAR DUCTROUND/FLAT OVAL ORANGLE TO WALLDO NOT BOLTSLIP JOINT (TYP)CONSTRUCTIONFIRE RATEDDAMPERFIREAD ADNOTES:1. HORIZONTAL DAMPER AND 80% FREE AREA INSTALLATION SIMILAR. 2. FOR DOUBLE WALL DUCT, USE INSULATION END CAP, INSULATE SLEEVE. 3. MC SHALL INSTALL DUCT SMOKE DETECTOR FURNISHED BY OTHERS.TO 48" WIDE DUCT),TO SLEEVE ONLYAND LARGER), FASTEN2 x 2, 12 GA. (49"1. HORIZONTAL AND 80% FREE AREA DAMPER INSTALLATION SIMILAR.2. OR DOUBLE WALL DUCT, USE INSULATION END CAP AND INSULATE SLEEVE.FIRE DAMPERTHAN THICKNESS OF WALLTHROUGHT WALL 6" LONGER14 GAUGE SLEEVE1 1/2 x 1 1/2 , 12 GA. (UPCONTINUOUS ANGLESLIP JOINT (TYP)ANGLE TO WALLRECTANGULAR DUCTROUND/FLAT OVAL ORACCESS DOOR: MINIMUM SIZE 16" x 12". IF DUCT IS LESS THAN 14" WIDE, PROVIDE 24" LONG REMOVABLE DUCT SECTION, FLANGED, GASKETED AND SECURED WITH WING NUTSDO NOT BOLTCONSTRUCTIONFIRE RATEDADIN LIEU OF DOORIN LIEU OF DOORSECURED WITH WING NUTSFLANGED, GASKETED ANDREMOVABLE DUCT SECTION,WIDE, PROVIDE 24" LONGIF DUCT IS LESS THAN 14"MINIMUM SIZE 16" x 12".ACCESS DOOR:EXTENDED THROUGH14 GAUGE SLEEVERECTANGULAR DUCTROUND/FLAT OVAL ORTO SLEEVE ONLYAND LARGER), FASTEN2 x 2, 12 GA. (49"TO 48" WIDE DUCT),1 1/2 x 1 1/2 , 12 GA. (UPCONTINUOUS ANGLEOPERATOR ACCESSIBLEWITH LINKAGE ANDLOCATE IN SLEEVESMOKE DAMPER,TO SMOKE BARRIERDO NOT BOLT ANGLESLIP JOINT (TYP)SMOKE BARRIERWALLNOTES:1. HORIZONTAL DAMPER INSTALLATION SIMILAR. 2. FOR DOUBLE WALL DUCT, USE INSULATION END CAP, INSULATE SLEEVE. 3. DAMPER SHALL BE WITHIN 2'-0" OF WALL.4. MC SHALL INSTALL DUCT SMOKE DETECTOR FURNISHED BY OTHERS.DISCONNECTNON-FUSEDPLATE (12" O.C.)SEAM FASTENINGSPLICING CEMENTROOF OPENINGGASKETNEOPRENEWHICHEVER IS CREATED.ROOF WARRANTY OR WARRANTY FOR 5 YEARS,BUILT UP ROOF SIMILAR, PROVIDE CANTS AND MAINTAIN1.BEFORE FABRICATIONREQUIREMENTS, VERIFYTO SUIT EQUIPMENTEPDM MEMBRANEMETAL FLASHINGTO CURB 8" O.C.SCREW EQUIPMENTROOF DECKROOF MEMBRANEINSIDE DIMENSIONSFRAMING40" MIN.18" MIN.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:38 PMM501DETAILS02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING7VANED ELBOW DETAIL10ROOFTOP AC UNIT DETAIL11RTU CURB DETAIL6TYPICAL CEILING REGISTER INSTALLATION DETAIL5TYPICAL DIFFUSER INSTALLATION DETAIL9PACKAGED ROOFTOP UNIT DETAIL8CONDENSATE DRAIN TRAP DETAIL - DRAW THRU UNIT4REFRIGERANT ROOF PENETRATION DETAIL1FIRE DAMPER / SMOKE DAMPER INSTALLATION DETAIL2FIRE DAMPER INSTALLATION DETAIL3SMOKE DAMPER INSTALLATION DETAIL12UPBLAST KITCHEN FAN DETAILREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REFRIGERANTPIPING FROMOUTSIDE UNITOR INTERIORBRANCHSELECTORSLONG SWEEPELBOW ORLONG BENDOF SOFTCOPPER (TYP)TYPICAL VRV "REFNET"REFRIGERANT BRANCHPIPING DEVICE INSTALLEDIN A TRUE AND LEVELPOSITION PARALLEL TOCEILING BELOW OR FLOORSTRUCTURE ABOVELONG SWEEPELBOW ORLONG BENDOF SOFTCOPPER (TYP)TO FCU ORBRANCH BOXTO FCU ORBRANCH BOXTO FCU ORBRANCH BOXMIN. 40" BETWEENPIPE ACCESSORIESTHE REFNET KITS ARE SUPPLIED WITH INSULATION INTENDED TO FIT OVER THE MAIN BODY OF THE"REFNET" JOINT AFTER INSTALLATION OF THE "REFNET" KIT IS COMPLETE.IMPORTANT:IN APPLICATIONS WHERE THE "REFNET" KITS ARE INSTALLED IN AN ENVIRONMENT REQUIRING FIRE-RATEDMATERIAL TO BE USED, IT IS NECESSARY FOR THE INSTALLER TO OBTAIN FROM A THIRD PARTY SUPPLIERAND TO UTILIZE, FOR INSULATION, FIRE-RATED MATERIALS THAT MEET ALL APPLICABLE BUILDING CODESAND OTHER REQUIREMENTS. THE FACTORY SUPPLIED INSULATION SHOULD BE DISCARDED IN A MANNERMEETING ALL APPLICABLE LAWS.MIN. 20" BEFORE ELBOWMIN. 20" AFTER ELBOW"REFNET" (TYPICAL)"REFNET" (TYPICAL)NOTE:IN CASES WHERE PIPING/TUBING NEEDS TO DROP BELOWOBJECTS, (BEAMS, DUCTS, CONDUITS, PIPES ETC.) PIPINGSHALL HAVE LARGE RADIUS TURNS AS INDICATED ABOVE(NO MORE THAN 45 DEGREES PER FITTING) TO PREVENTTRAPPING OF REFRIGERANT.45 deg. MAX45 deg. MAX4" MAX4" MAXNOTE:CALCULATION FOR EXPANSION AND CONTRACTION SHOULD BE BASED ON THE AVERAGE COEFFICIENT OF EXPANSIONOF COPPER WHICH IS 0.0000094 INCH PER INCH PERDEGREE F, BETWEEN 70°F AND 212°F.(EXAMPLE: EXPANSION OF A 100 DEGREE F RISE FOR EACH100 FT. OF ANY SIZE IS 1.128 INCHES)EXPANSION DIMENSION "L" FOR OFFSET & RETURN TO BEBASED ON THE EXPECTED EXPANSION INCHES PERDIMENSION OF PIPEGUIDEBRACKETLENGTH "L" = INCHES OFFSET & RETURNSLEEVE"L"RECOMMENDED EQUIPMENT CLEARANCES:3" ABOVE12" ENTERING (3 PIPE)IN SPACE CONDITIONS THAT DO NOT ALLOW 3" ABOVE THEDEVICE, MAINTAIN A 1" AIR SPACE BELOW UPPER DECK ANDINSTALL 1/2" FOAM INSULATION ON THE TOP OF THE DEVICE.HANGERS (TYP)HANGERS (TYP)20" MINIMUM20" MINIMUMBRANCHSELECTORUNITHANGERS (TYP)TYPICAL FAN COILTYPICAL ALL FAN COIL UNITS20" MINIMUMCONTRACTOR TO INSTALL LINE SIZE SHERWOOD MODEL"WAS" REFRIGERANT SHUT-OFF VALVES WITH ACCESSFITTING. ALL VALVES SHALL INCORPORATE DUAL STEMSEAL DESIGN W/TEFLON PACKING INTERNAL PRIMARYSEAL. VALVE SHALL PERMIT OPERATION WITHOUTREMOVAL OF SEALS OR TEFLON GASKETS. PROVIDEW/INTERNAL BALL TYPE RELIEF PORT FOR DUALDIRECTIONAL SHUT-OFF. PROVIDE FULL FLOW PORTS ONALL SIZES 1/4" THROUGH 7/8". (NOTE: SHUT-OFF VALVESSHALL BE ZERO-CLEARANCE TYPE, ALL BRONZE, BRAZEDCONNECTIONS WITH 1/4" SCHRADER TYPE SERVICE FITTINGIN VALVE. TYPICAL FOR EACH LINE).NOTE: CONTRACTOR TO PROVIDE 5/16" THREADEDROD HANGERS WITH DOUBLE SIDED RUBBER (1/2"THICK) ISOLATORS AT EACH SUSPENSION BRACKET (4EACH) ON BRANCH SELECTOR FOR SUSPENSION OFUNITINSTALL BRANCH SELECTOR A MINIMUM OF 12"x 15-1/4"CLEAR FOR ELECTRICAL SERVICE TO ELECTRIC BOXSECTION(HP) LIQUID REFRIG. LINE(FROM OUTDOOR UNIT)(HP) HOT GAS REFRIG. LINE(FROM OUTDOOR UNIT)(LP) SUCTION REFRG.LINE (TO OUTDOOR UNIT)1/4" SERVICE FTG.(TYP) EACH VALVE(HP) LIQUID REFRIG. LINE (TOINDOOR UNIT)BRANCHSELECTOR UNIT(LP) SUCTION REFRIG. LINE(FROM INDOOR UNIT)ELECTRICAL BOXSECTION(ON SIDE OF UNIT)ENTRANCE SIDELEAVING SIDEALUMINUMJACKET OVERINSULATIONUNISTRUTPIPE CLAMPUNISTRUTSUPPORTREF. PIPE803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:40 PMM502VRF DETAILS02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1DIAGRAM - REFNET PIPING CLEARANCE REQUIREMENTS7ELEVATION - PIPING OFFSET BELOW OBJECT5PLAN - EXPANSION LOOPS3RECOMMENDED PIPE CLEARANCES FOR BRANCH SELECTOR UNITS4RECOMMENDED PIPE CLEARANCES FOR INDOOR UNITS2TYPICAL BRANCH SELECTOR PIPING6REFRIGERANT PIPE UNISTRUT SUPPORTREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 C/PHDBMSMVFDMMJPBCBSDDCCR A A AT AFATSMTSSSSSVMMICPAPACCBPSOHADHDHDHECTSFCZIAPSFSDAMMTTTSWBSWBSWBSWBTVTVTELSWBTSVCRDCKPSMDSSERMLICELRELPSIDCCY12:00WSHSDSSFWPACSCHEMATIC SYMBOLSHEALTH CAREMISCELLANEOUSPUBLIC ADDRESSSECURITYLIGHTINGPOWERONE LINE SYMBOLSNOTE:ABBREVIATIONS:POWER DISTRIBUTIONFIRE ALARM SYSTEMCOMMUNICATIONS11AaACAACVALMAVRAVSBACVBFMCCCCTCSCTDCADCVDMD(E)EECECSESPBERLETRFFTGALGENIACVIFMLTSMCMPUNOPCPTS1S2SCSSHTCSILSSSTBSYNCTSVARWREWTD- NORMALLY OPEN AUXILIARY CONTACT-AC AMMETER-AC VOLTMETER-ALARM- AUTOMATIC VOLTAGE REGULATOR- AMMETER / VOLTMETER PHASE SELECTOR SWITCH- BUS AC VOLTMETER- BUS FREQUENCY METER- INDICATING LIGHT C.B. CLOSED- CROSS COUPLED CURRENT TRANSFORMER- CIRCUIT BREAKER CONTROL SWITCH- CURRENT TRANSFORMER-DC AMMETER-DC VOLTMETER- DIGITAL METERING DISPLAY-EXISTING- EMERGENCY SOURCE- ELECTRICAL CONTRACTOR- ENGINE CONTROL SWITCH- EMERGENCY STOP PUSHBUTTON- EXISTING TO BE RELOCATED- EXISTING TO REMANI-FUSE-FLEXITEST SWITCHES- GENERATOR AVAILABLE LIGHT- GENERATOR- INCOMING AC VOLTMETER- INCOMING FREQUENCY METER- LAMP TEST PUSHBUTTON- MECHANICAL CONTRACTOR- MAGNETIC PICK-UP- NORMAL SOURCE- INDICATING LIGHT C.B. OPEN- PLUMBING CONTRACTOR- POTENTIAL TRANSFORMER-SOURCE 1-SOURCE 2- SYSTEM CONTROL SWITCH- SHUNT TRIP COIL- ALARM SILENCE PUSHBUTTON- SYNCHRONIZING SWITCH- SHORTING TERMINAL BOARD- SYNCHROSCOPE- TEMPERATURE SCANNER- VOLTAGE ADJUST RHEOSTAT- WARNING RESET PUSHBUTTON- WATT TRANSDUCER1. NOT ALL SYMBOLS, ABBREVIATIONS AND LINE DESIGNATIONS ARE NECESSARILY USED ON THIS PROJECT.HAND-OFF-AUTO SELECTORN.C. RELAY CONTACTN.O. RELAY CONTACTN.C. PUSHBUTTONN.O. PUSHBUTTONSOLONOID VALVE COILN.O. FLOW SWITCHN.C. FLOW SWITCHN.O. TEMPERATUREN.C. PRESSURE SWITCHN.O. PRESSURE SWITCHN.C. LEVEL SWITCHN.O. LEVEL SWITCHN.O. LOW LIMIT SWITCHEMERGENCY STOPN.C. HIGH LIMIT SWITCHN.O. HIGH LIMIT SWITCHN.C. LOW LIMIT SWITCHN.C. TEMPERATURE SWITCHINDICATOR LIGHTMAGNETIC DOOR CONTACTSPECIAL INTRUSION DETECTION SENSORCONNECT TO SECURITY SYSTEMHARDWARE OR DEVICE PROVIDED BY OTHERS.ELECTRO MAGNETIC LOCKINTRUSSION DETECTION CONTROL CENTERCLOSED CIRCUIT TELEVISION CAMERA (FIXED)CLOSED CIRCUIT TELEVISION CAMERA (PAN-TILT-ZOOM)ELECTRIC LATCH RETRACTION BARKEYPAD POWER SUPPLYELECTRIC LATCH RETRACTION BAR POWER SUPPLYDOUBLE FACESINGLE FACEBATTERYDOUBLE FACESENSORCEILING MOUNTEDDESCRIPTIONSTATIONSTATION (MAKE/MODEL JERON 7919)NURSE CALL MASTERNURSE CALL DOME LIGHT/ROOM CONTROLLER(MAKE/MODEL JERON 7953)NURSE CALL CODE EMERGENCYWALL MOUNTED EXIT SIGN,WALL MOUNTED COMBINATIONEXIT SIGN/EMERGENCYEGRESS LIGHTING, SINGLECEILING MOUNTED EXIT SIGN,LIGHTING CONTACTORCEILING MOUNTED EXIT SIGN,EMERGENCY LIGHTINGFIXTURE WITH INTEGRALEMERGENCY LIGHTINGFIXTURE WITH REMOTEBATTERY (TWO HEADS)EMERGENCY LIGHTINGFIXTURE WITH REMOTEBATTERY (SINGLE HEAD)WALL MOUNTED OCCUPANCYOCCUPANCY SENSORNOTEDESCRIPTIONREFERENCE TO DRAWINGSCHEDULEREFERENCE TO FEEDERROOM NUMBERARROWHEAD LINESYMBOLTERMINATORSYMBOLWIRE SIZE, WIRE COUNT,AND CONDUIT SIZE ASNOTEDWIRE MOLD/ PLUG MOLDDROP CORDPOWER POLECORD REELBREAKERRECEPTACLEPOWER CONNECTIONSINGLE FACE PEDESTALDOUBLE FACE PEDESTALEMERGENCY POWERBOXBOXJUNCTION BOXELECTRIC METERENCLOSED CIRCUITBUSPLUGPULLBOXFACESPEAKER CLUSTERVOLUME CONTROLPUBLIC ADDRESS EQUIPMENTPUBLIC ADDRESS CONTROLPUBLIC ADDRESS SPEAKERWALL MOUNTED MICROPHONEFLOOR MOUNTEDMICROPHONE OUTLETWALL MOUNTED CLOCKLETTER REFERS TOTYPE IN SPECIFICATIONSCLOCK SYSTEM BOOSTERPUBLIC ADDRESS INTERCOMPOWER SUPPLYI - IMPULSE TYPES - SYNCHRONOUS TYPEOUTLETSTATIONCENTERRACKELRPSKPPSINTERCOMELECTRIC LOCKPOWER SUPPLYINDICATES TYPE:A - AMMETERV - VOLTMETERMANUAL TRANSFER SWITCHMETER DESIGNATIONKWH - KILOWATT-HOURAMMETER SELECTORGROUND FAULTVOLTMETER SELECTORDRAW OUT DEVICEDESCRIPTIONDESIGNATION REFERS TOTYPE IN SPECIFICATIONWALL MOUNTED SPEAKER,TYPE IN SPECIFICATIONPROFESSIONAL QUALITYDESIGNATION REFERS TOCEILING MOUNTED SPEAKER,SPEAKERSYMBOLSWITCHSWITCHMETERMOTION DETECTOREXIT REQUESTKEYPADCARD READERDESCRIPTIONSYMBOLRELAY COILDESCRIPTION- OCCUPANCY SENSOR OPERATEDSWITCHINGDIMMER SWITCHPHOTO CONTROLDOWNLIGHTDOWNLIGHT4 FT. TRACK LIGHTDESIGNATION REFERS TOFIXTURE SCHEDULESINGLE POLE LIGHT SWITCHTHREE WAY LIGHT SWITCHFOUR WAY LIGHT SWITCHTIME CLOCK / SWITCHSINGLE POLE LIGHT SWITCHINDICATES MULTI-LEVELRECESSED FIXTURE,INDICATES FIXTURE ONEMERGENCY CIRCUITROUND RECESSED12" SQUARE RECESSEDWALL MOUNTED FIXTURE,DESIGNATION REFERS TOFIXTURE SCHEDULEWALL MOUNTED EXIT SIGN,ROUND WALL SCONCESTRIP FIXTURESQUARE WALL SCONCESPECIAL PURPOSE OUTLET,DRIVE, DESIGNATION REFERSMOTOR CONNECTION,DESIGNATION REFERS TOELECTRIC EQUIPMENTCONTROL SCHEDULE.VARIABLE FREQUENCYTO ELECTRIC EQUIPMENTCONTROL SCHEDULE.MANUAL MOTOR STARTER,INTERGRAL HORSEPOWER,PUSH BUTTON OPERATORELECTRIC EQUIPMENTCONTROL SCHEDULE.MANUAL MOTOR STARTER,FRACTIONAL HORSEPOWER,TOGGLE OPERATORCOMBINATION MAGNETICMOTOR STARTER/DISCONNECT SWITCH,DESIGNATION REFERS TOELECTRIC EQUIPMENTCONTROL SCHEDULE.BELL OR BUZZERFUSED DISCONNECT,DESIGNATION REFERS TOELECTRIC EQUIPMENTCONTROL SCHEDULE.NONFUSED DISCONNECT,DESIGNATION REFERS TOELECTRIC EQUIPMENTCONTROL SCHEDULE.MAGNETIC MOTOR STARTER,DESIGNATION REFERS TOPUSHBUTTONSUBSCRIPT REFERS TOELECTRIC HAND DRYERELECTRIC EQUIPMENTCONTROL SCHEDULEPOWER / COMMUNICATIONPOLESYMBOLWEATHERPROOFFLOOR BOXSURGE SUPPRESSIONABOVE COUNTERFLOOR RECEPTACLEBOX (QUAD)RECEPTACLEINTERRUPTERDUPLEX RECEPTACLETWO DUPLEX IN TWO GANGSPLIT WIRED DUPLEXGROUND FAULTDESCRIPTIONSYMBOLSOLID STATE BREAKERDESIGNATIONS INDICATECL - CURRENT LIMITINGL - LONG TIME TRIPS - SHORT TIME TRIPG - GROUND FAULT TRIPI - INSTANTANEOUS TRIPSHUNT TRIP TYPE CIRCUITFUSED DISCONNECT SWITCHBRANCH CIRCUITDISTRIBUTION PANEL,REFER TO PANELBOARDGROUND CONNECTIONAUTOMATIC TRANSFEREMERGENCY GENERATORSCHEMATIC MOTORLIGHTNING ARRESTORSWITCHSCHEDULESBREAKERFUSEFUNCTIONS:PUSHBUTTONN.C. SWITCHN.O. SWITCHSWITCHTRANSFORMERCURRENT TRANSFORMERPOTENTIAL TRANSFORMERAMPERE RATINGDRAW-OUT TYPE,AMPERE RATINGTHERMAL MAGNETIC MOLDEDCASE CIRCUIT BREAKERDESIGNATION INDICATESTHERMAL MAGNETIC MOLDEDCASE CIRCUIT BREAKERDESIGNATION INDICATESSYMBOLDESCRIPTIONSWITCHDESCRIPTIONSYMBOLBRANCH CIRCUIT240/120V REFER TOPANELBOARD 208Y/120V ORPANELBOARD SCHEDULE1200A MAX REFER TO800A MAX REFER TODISTRIBUTION PANELBOARDPANELBOARD SCHEDULEDISTRIBUTION PANELBOARDPANELBOARD SCHEDULEMOTOR CONTROL CENTERSWITCHBOARD SECTION120V, (500 KVA SIZE3-45 KVA TRANSFORMER75-225 KVA TRANSFORMERTRANSFORMER 480-208Y/SHOWN) DESIGNATION REFERSTO TRANSFORMER SCHEDULE(800-2000AMP SIZE SHOWN)2500 AMP SWITCHBOARD3000 AMP SWITCHBOARD4000 AMP SWITCHBOARDDOOR HOLDERCONNECTION TO ROOFWALL MOUNTED LOUVERCAPTURE CONTROLSYSTEM TAMPER SWITCHFIRE ALARM SYSTEMEMERGENCY PHONEFLOOR MOUNTED MAGNETICCONNECTION TO MAGNETICDOOR HOLDER PROVIDED BYMOUNTED SMOKE HATCH ORCONNECTION TO SPRINKLERCONNECTION TO ELEVATORCONNECTION TO SPRINKLERFIRE ALARM REMOTEANNUNCIATOR PANELZONE ADDRESS MODULES - SIGNAL DEVICESD - DOOR HOLD OPENSINDIVIDUAL ADDRESS MODULEAUXILLARY POWER SUPPLYCOLLECTIVE ZONE INTERFACEFIRE ALARM CONTROL PANELFLOW SWITCHDOOR HOLDERTHE ARCHITECTSECTIONSECTIONSECTIONMANUAL PULL STATIONDUCT MOUNTED SMOKEWALL MOUNTED MAGNETICLETTER REFERS TO TYPEINDICATES AUXILLIARYVISUAL FIRE ALARM STROBECEILING MOUNTED SMOKECEILING MOUNTED THERMODETECTOR LETTER REFERSTO TYPE IN SPECIFICATIONSAUDIO-VISUAL FIRE ALARMCONTACTS ON FIRE ALARMDEVICEIN DESCRIPTIONDETECTORDETECTORDESCRIPTIONSYMBOLSECTIONSYMBOLDESCRIPTIONTELEPHONE SWITCHREMOTE TELEPHONE RINGERCOMMUNICATIONS EQUIPMENTCABLE TV SPLITTERVIDEO OUTLETRACK/ BUZZERCABLE TV TAPCOMPUTER/DATAWALL MOUNTED CABLECOMMUNICATION OUTLET,DESIGNATION REFERS TODATA COMMUNICATIONSCOMMUNICATION OUTLET, INDESIGNATION REFERS TODATA COMMUNICATIONSTELEPHONE OUTLET INTELEVISION SYSTEM OUTLETCEILING MOUNTED CABLETELEVISION SYSTEM OUTLETWIRING SCHEDULEFLUSH FLOOR BOX,WIRING SCHEDULETELEPHONE OUTLETFLUSH FLOOR BOXCOMPUTER/DATACOMPUTER/DATADESCRIPTIONSYMBOLCEILING MOUNTED CARBONMONOXIDE DETECTORFAN SHUTDOWNADDRESSABLE MONITOR MODULESMOKE DAMPERVOICE CONTROL CENTER PANELANNUNCIATOR PANELNOTIFICATION APPLIANCEEXTENDER PANEL- KEY OPERATEDSINGLE POLE LIGHT SWITCHORWALL MOUNTED DIGITALCLOCK LETTER REFERS TOTYPE IN SPECIFICATIONSWALL MOUNTED CLOCK ANDSPEAKER LETTER REFERS TOTYPE IN SPECIFICATIONSWIRELESS CLOCK TRANSMITTERNSDGFIMEOSOSLCEMPCTCa,bS4S3SKSosSSTGASVSGFFSSDFFHCOAUXFFACPRAPVCCPNAEPZAMIAMPPCCTVCCTVPTZCEILING MOUNTEDOCCUPANCY SENSORVSRAREA OF REFUGE CALL STATIONCEILING MOUNTED VISUAL FIRE ALARM STROBECEILING MOUNTED AUDIO-VISUAL FIRE ALARMFFGROUND FAULT INTERRUPTERDUPLEX RECEPTACLEREQUIRED 2020 IECC ENERGY CONSERVATION COMPLIANCECODE SECTIONCOMPLIANCEC303.3 OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER BY CONTRACTOR FOR ALL EQUIPMENTC401.2 BUILDING COMPLIES WITH THE APPLICABLE SECTIONS OF CODE BASED ON METHOD 2C402.5 REFERENCE ARCHITECTURAL PLANS FOR AIR LEAKAGE CRITERIA C403.2.1HVAC LOAD SIZING HAS BEEN PERFORMED IN THE CARRIER HAP PROGRAM, USING RTS (HEAT BALANCE) METHODOLOGYC403.2.3 ALL HVAC EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE MECHANICAL DOCUMENTSC403.2.4 REQUIRED HVAC CONTROLS SHALL BE PROVIDED, REFERENCE MECHANICAL DOCUMENTSC403.2.4.3MOTORIZED DAMPERS PROVIDED FOR EXHAUST AND OUTSIDE AIR INTAKES GREATER THAN 300 CFM OR IN BUILDINGS 3 STORIES OR LESSC403.2.9.1 DUCT IS REQUIRED TO BE INSULATED TO THE INDICATED MINIMUM LEVEL, REFERENCE MECHANICAL DOCUMENTSC403.2.9.3 INSTALLING CONTRACTOR SHALL ENSURE THAT ALL AIR DISTRIBUTION COMPONENTS ARE PROPERLY SEALEDC403.2.9.5 DUCT SIZING AND DUCT DESIGN HAS BEEN PERFORMED, REFERENCE MECHANICAL DOCUMENTSC403.2.10 ALL PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE MECHANICAL / PLUMBING DOCUMENTSC403.2.11 MECHANICAL SYSTEMS SHALL BE COMMISSIONED AS REQUIREDC404.2 ALL WATER HEATING EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE PLUMBING DOCUMENTSC404.4 ALL DOMESTIC HOT WATER PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE PLUMBING DOCUMENTSC405.2 LIGHTING CONTROL CRITERIA HAS BEEN MET, REFERENCE ELECTRICAL DOCUMENTSC405.5 EXTERIOR LIGHTING TOTAL POWER DOES NOT EXCEED THE ALLOWANCE, REFERENCE ELECTRICAL DOCUMENTSC405.6 ELECTRICAL POWER HAS BEEN PROVIDED PER THE CODE REQUIREMENTS, REFERENCE ELECTRICAL DOCUMENTSC408.2.2 INSTALLING CONTRACTOR SHALL TEST AND BALANCE ALL HVAC SYSTEMS AND PROVIDE REPORT TO ENGINEERMECHANICAL DESIGN CONFORMS TO 2020 IECC AND IMC CODE REQUIREMENTSC103.2.1REFERENCE ARCHITECTURAL PLANS FOR FENESTRATION U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSREFERENCE ARCHITECTURAL PLANS FOR AREA-WEIGHTED U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSC103.2.2C103.2.3C103.2.4C103.2.5C103.2.6C103.2.7C103.2.8C103.2.9C103.2.10C103.2.11C103.2.12REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR DUCT AND PIPE INSULATION MATERIALS, ARCHITECTURAL DOCUMENTS FOR ALL OTHER INSULATION MATERIALSREFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENTAMD SYSTEM CONTROLSREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT HORSEPOWER AND CONTROLSREFERENCE MECHANICAL AND PLUMBING SPECIFICATIONS FOR SEALING AND INSULATION LOCATIONSREFERENCE ELECTRICAL DOCUMENTS FOR LIGHTING FIXTURE SCHEDULE AND CONTROLSREFERENCE ELECTRICAL DRAWINGS FOR DAYLIGHTING ZONESREFERENCE MECHANICAL SPECIFICATIONS FOR AIR SEALING DETAILSRPTWO WAY COMMUNICATION CALL BOXRATH MODEL 2100 CALL BOXNOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE ELECTRICAL SCOPE. MATERIALS, LIGHTING QUALITY, LIGHTING CONTROLS, LIGHTING POWER DENSITY, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 260800 AND 019113 FOR COMMISSIONING REQUIREMENTS.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:56:07 PME001LEGEND &ABBREVIATIONS02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGTO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT, THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE INTERNATIONAL ENERGY CODE, AS ADOPTED BY THE STATE.ENERGY CONSERVATION CODE COMPLIANCE STATEMENTREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 POSTPOSTMB ON WALKRAILROAD TRACKRAILROAD TRACK2"GM 2"GM 2"GM DASHED WHITE LANE STRIPESOLID WHITENOTE:YELLOW CENTER MEDIAN STRIPE POINTS LOCATED INFIELD 02.06.19 DO NOT MATCH SITE PHOTOGRAPHSYELLOW CENTER MEDIAN STRIPEDASHED WHITELANE STRIPESONW INV. 8'PVC 384.92139 LF 8"PVC ST. @ 0.37%188 LF 36"RCP SAN. @ 0.01%310 LF 36"RCP SAN. @ 0.11%185 LF 36"RCP SAN. @ 0.30%207 LF 36"RCP SAN. SEWER6' CHAIN LINK FENCEEDGE OF ASPHALT PAVEMENTEGUY WIRES (TYPICAL)NYSE&G #8NYSE&G #9NYSE&G NO#NYSE&G #7ONE STORY MASONRY BLDG.PPPPBKPPPP℄ SEVENTH STREET(UNOPENED STREET)BIO R ETEN TIO N G .I.#3BIO RETENTION G.I.#3B IO RETEN TIO N G .I.#3BIO RETENTION G.I.#1BIORETENTIONG.I. #5BIORETENTIONG.I. #4BIORETENTIONG.I. #7B4/23BUILDING C4/2 STORIES MIXED USE64 UNITS23,678 SF FOOTPRINTWATERLINEEASEMENTINSTRUMENT#2016-02718 &573432-001250KW/312.5KVADIESEL GENERATOR6" CONCRETE PADPROTECTIVE BOLLARDSEV CAR CHARGINGPROVIDE (2) 1 1/2" SCEDULE 80 PVC CONDUITS, DIRECT BURIEDPROVIDE 1 1/2" SCEDULE 80 PVC CONDUITS, DIRECT BURIEDPROVIDE 1 1/2" SCEDULE 80 PVC CONDUITS, DIRECT BURIEDPROVIDE 2" SCEDULE 80 PVC CONDUITS, DIRECT BURIEDPROVIDE 2" SCEDULE 80 PVC CONDUITS, DIRECT BURIED(9)4" SCHEDULE 80 PVC CONDUITS, DIRECT BURIED, TO UTILITY TRANSFORMERPROVIDE 2" SCEDULE 80 PVC CONDUITS, DIRECT BURIEDPROVIDE 2" SCEDULE 80 PVC CONDUITS, DIRECT BURIEDPROVIDE 2" SCEDULE 80 PVC CONDUITS, DIRECT BURIED1PROVIDE (3)4" SCHEDULE 80 PVC CONDUIT FOR GENERATOR FEEDERS AND (3)1 1/2" SCHEDULE 80 PVC CONDUIT FOR CONTROLS, BLOCK HEATER AND BATTERY CHARGER, DIRECT BURIED34EP-1A/8EP-1A/755555588884444REFER TO CIVIL DRAWINGS FOR FIXTURE TYPE, POLE, AND BASE. (TYPICAL)PP1A/31,33 PP1A/32,34GROUND GRID8PROVIDE 1 1/2" SCEDULE 80 PVC CONDUITS, DIRECT BURIEDPROVIDE 2" SCEDULE 80 PVC CONDUITS, DIRECT BURIED44PROVIDE 2" SCEDULE 80 PVC CONDUITS, DIRECT BURIED803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:56:12 PME100SITE PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1" = 30'-0"1SITE PLANDRAWING NOTES:1PROVIDE (2)40A, 208V, SINGLE PHASE CIRCUITS FOR CAR CHARGING STATION. FEED EACH CIRCUIT WITH 3-#3 & 1-#10EG IN 1" CONDUIT. PROVIDE 1" SCHEDULE 80 PVC CONDUIT WITH PULLSTRING FOR NETWORK CABLE.PROVIDE (3)4" SCHEDULE 80 PVC CONDUIT FOR GENERATOR FEEDERS AND (1)1 1/2" SCHEDULE 80 PVC CONDUIT FOR CONTROLS, DIRECT BURIED.PROVIDE 2-#12, 1-#12EG, 1" CONDUIT FROM 20A/1P CIRCUIT BREAKER IN PANEL SHOWN AND MAKE REQUIRED CONNECTIONS AT BLOCK HEATER.PROVIDE 2-#12, 1-#12EG, 1" CONDUIT FROM 20A/1P CIRCUIT BREAKER INPANEL SHOWN AND MAKE REQUIRED CONNECTIONS AT BATTERY CHARGER.PROVIDE 1" SCHEDULE 80 PVC CONDUIT TO LIGHT POLE FOR FROM BUILDING FOR LOW VOLTAGE SECURITY CABLING.234A. A.THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ELECTRICAL CONDUIT, MANHOLES, CABLE, AND TERMINATIONS.B. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL COMMUNICATIONS CONDUIT AND HANDHOLES.C. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE PROPER UTILITIES INCLUDING ALL UTILITIES PRIVATELY OWNED AND STAKING OUT ALL UTILITIES PRIOR TO BEGINNING ANY WORK. VERIFY ALL UTILITY LOCATIONS PRIOR TO TRENCHING TO AVOID DAMAGE TO EXISTING UTILITIES. SPRAY PAINT LOCATION OF UTILITIES ON ASPHALT AND CONCRETE AND PROVIDE STAKES ON GRASS OR DIRT SURFACES. REMOVE SPRAY PAINT FROM ASPHAULT AND CONCRETE ONCE PROJECT IS COMPLETE.D. HAND EXCAVATE WHERE NECESSARY TO AVOID CAUSING DAMAGE TO EXISTING UTILITIES AND SERVICES. PROVIDE OWNER WITH 7 WORKING DAYS NOTICE OF ANY SHUTDOWNS.E. COORDINATE ALL CUTTING AND PATCHING OF SIDEWALKS AND DRIVEWAYS WITH GENERAL CONTRACTOR PRIOR TO BEGINNING CONSTRUCTION. E.C. IS TO REPAIR ALL EXISTING ASPHAULT AND CONCRETE AS REQUIRED FOR INSTALLATION OF CONDUITS.F. ALL EXCAVATION AND BACKFILL FOR THE ELECTRICAL SITE WORK IS BY THE ELECTRICAL CONTRACTOR. COORDINATE ALL WORK WITH THE SITE CONTRACTOR.G. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC MAINTENANCE AND SAFETY, ASPHALT CUTTING, EXCAVATION, BACKFILL, SEEDING AND CONCRETE WORK REQUIRED FOR THE INSTALLATION OF ELECTRICAL WORK. ALL REPAIR SHALL BE BY THE ELECTRICAL CONTRACTOR AFTER ALL ELECTRICAL WORK IS COMPLETE.H. ROUTE ALL CONDUIT PENETRATIONS SHOWN UNDER BUILDING FOUNDATIONS TO EACH BUILDINGS MECHANICAL SPACE.I. ALL WIRING SHALL CONFORM TO THE NATIONAL ELECTRIC CODE.J. PROVIDE 5/8" DIAMETER x 8' COPPERWELD GROUND ROD AT EACH POLE LOCATION.GENERAL NOTES:5REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.FACPATSATSFFF F FFFFFFFFFFFFFFFT V T V TVTVFFF F FFFFFFF FFFFFFFFFFFFFFFFFT V SSSSSSSSSSSSSSSSSF FFFSSSSSSSSSSSSSSSF R A P FFFFFFJJJMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMTVMMMMMMMMMMMSHSHF MMJDHDHDHDHCRCRJCRJDHFFE NENM MJMMMWASTEHOLDING136PUBLICTOILET100AEVS109EXAM121EXAM120EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1EXAM112SOILEDWORK111EXAM118CLEANSUPPLY134STAFFBREAK133SOILED132REGISTRATION124INCOMING FEEDERMETERING SECTIONDISTRIBUTION SECTIONMAIN BREAKERPP1BPP1ADP1GDPSBDPEMDPATS-SBATS-EMEP-1ASBP-1ACORRIDOR122151515151515WPWP15151515151515151515151515303030301515151515151515151515151515151515SPECIMENTOILET127HOLDING/MAIL100CVITALSALCOVE105ACIRCULATION105CIRCULATION105CIRCULATION105SUB-WAITING105BSTAIR2ST2-1BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125RADIOLOGY(X-RAY)119CORRIDOR143TREATMENT117EXAM113STATLAB/MED110CLEANHOLDING107SHAREDPROVIDEROFFICE104STAFFBREAK102BUILDINGMAINTENANCETOILET/SHOWER138A60"ACACAC172"AC60"1ACAC AC15AC48"48"48"ACACACAC60"ACACACACACACACACAC ACACACIN PITIN PIT2ACAC ACAC148"48"AC15AC48"48"48"3060"172"1ACAC AC21530222151515151515 ACACUSBUSBUSBUSBUSBUSBUSBUSBUSBUSB USBAC3USBUSBWPWPWPWPWPWP444RECEPTION101BLOBBY/WAITING101VISITORTOILET101APUBLICTOILET100BHWH-1AHWRP-1ADFC-07BDFC-15BDFC-09BDFC-07ADFC-15ADFC-05IDFC-18ADFC-09SDFC-05GDFC-05HDFC-15EDFC-07DDFC-05CDFC-12RDFC-05BDFC-05FDFC-05DDFC-15DDFC-12BDFC-05ADFC-09RDFC-12ADFC-24BDFC-24ADFC-30ASBP-1A/48SBP-1A/55PP1A/19SBP-1A/41PP1A/25SBP-1A/3SBP-1A/14SBP-1A/12SBP-1A/51SBP-1A/17SBP-1A/18PP1A/9SBP-1A/22PP1A/22SBP-1A/4SBP-1A/8SBP-1A/13PP1A/16PP1A/14PP1A/15PP1A/13PP1A/12PP1A/27EP-1A/3PP1A/4PP1A/3PP1A/6PP1A/5PP1B/15PP1A/2PP1A/23EP-1A/3PP1A/28EP-1A/4PP1A/7PP1A/24PP1A/20SBP-1A/43SBP-1A/44ACPP1A/16PP1A/16PP1A/15PP1A/15PP1A/1PP1A/1PP1A/7PP1B/6PP1A/1PP1A/8PP1A/8PP1A/10PP1A/18SBP-1A/4SBP-1A/46SBP-1A/47SBP-1A/47SBP-1A/49PP1B/4PP1A/30EP-1A/6BS-13DBP-1CUH-1ASBP-1A/20SBP-1A/21SBP-1A/23BS-1PP1B/3PP1B/1PP1B/2PP1B/23PP1B/24 PP1B/25PP1B/8BS-454"54"54"48"SBP-1A/2BS-2BS-3PP1A/2948"30PP1A/9SBP-1A/16SBP-1A/42ACSBP-1A/24SBP-1A/52SBP-1A/53 SBP-1A/54SBP-1A/50ACPP1A/2172"1SBP-1A/45PP1B/12PP1B/14PP1B/13SBP-1A/448"SBP-1A/11SBP-1A/10SBP-1A/92E101PROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIESPROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIES, TO SECOND FLOORBS-14PP1A/17548"48"BS-6BS-7BS-8BS-11BS-12BS-10BS-548"5548"548"5548"548"48"48"55548"5BS-9PP1B/17AC-18AAC-18BAC-18CESP-1AESP-1BTWO-WAY COMMUNICATION HEADENDEP-1A/9FIRE BELLAC-2AC-14EP-1A/3SBP-1A/16SBP-1A/16EP-1A/3SBP-1A/156SBP-1A/3764EP-1A/34EP-1A/36SBP-1A/38SBP-1A/3966SBP-1A/40661515T-X1T-X24EP-1A/11E601PP1A/1148"48"SBP-1A/56BF-1ATSFTSTSTSTSTSLCP-178888888SD9SD9SD9SD9SD9SD9SD9SD9SD9SD9SD9SD9SD9SD98GROUND BARPROVIDE 3/4" FIRE TREATED PLYWOOD BACKBOARD FROM 2' AFF TO CEILING ON WALL SHOWN, PAINT GRAYL6-30R TWISTLOCK,(TYPICAL OF 6)SBP-1A/5PP1A/16SBP-1A/7SBP-1A/6PROPOSED RACKS BY OTHERSSBP-1A/25,27SBP-1A/26,28SBP-1A/29,31SBP-1A/30,32SBP-1A/33,35SBP-1A/34,36PROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIESPROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIES803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:56:24 PME101FIRST FLOORPOWER &SYSTEMS PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGDRAWING NOTES:1GENERAL NOTES:A. INSTALL CONDUIT PERPENDICULAR, PARALLEL, AND TIGHT TO STRUCTURE COLUMNS AND BEAMS. COORDINATE EXPOSED CONDUIT ROUTING WITH ARCHITECT AND ENGINEER.B. LABEL CONDUIT PER SPECIFICATION.C. PROVIDE TYPE WRITTEN PANELBOARD SCHEDULES FOR ALL PANELS. D. PROVIDE BLANK COVERPLATES ON ALL UNUSED OUTLET BOXES.E. PROVIDE 4 11/16" SQUARE OUTLET BOX WITH 2-GANG MUD RING FOR ALL VOICE/DATA OUTLETS SHOWN. PROVIDE 1" CONDUIT FROM OUTLET BOX TO ACCESSIBLE CORRIDOR CEILING SPACE. PROVIDE PLASTIC BUSHINGS ON BOTH ENDS OF CONDUIT. IN AREAS WHERE CABLE TRAY IS IN CORRIDORS, RUN CONDUIT TO CABLE TRAY. PROVIDE #6 BONDING WIRE BETWEEN CONDUIT AND CABLE TRAY. COORDINATE INSTALLATION WITH TELECOMMUNICATIONS DEPARTMENT. PROVIDE PULL STRINGS IN ALL VOICE/DATA OUTLETS.F. COORDINATE ALL CONDUIT RUNS WITH OTHER TRADES PRIOR TO ROUGH-IN. RELOCATE ANY CONDUITS AS NECESSARY TO PERMIT INSTALLATION OF DUCTWORK OR PIPING.G. REFER TO ARCHITECTURAL ELEVATIONS FOR DEVICE LOCATION AND MOUNTING HEIGHT PRIOR TO ROUGH-IN.H. FIRESTOP ALL PENETRATIONS THROUGH FIRE AND SMOKE WALLS.I. ALL WIRING SHALL BE PLENUM RATED.J. PROVIDE TAMPERPROOF RECEPTACLES FOR ALL RECEPTACLES SHOWN IN CORRIDORS, LOBBIES, AND STAIRWELLS.K. ALL RECEPTACLES IN PATIENT CARE AREAS SHALL BE HOSPITAL GRADE TAMPER-PROOF EQUAL TO HUBBELL HBL8300 SERIES. NORMAL RECEPTACLES SHALL BE COLOR BY ARCHITECT, RECEPTACLES CONNECTED TO EP PANELS SHALL BE RED.L. FOR BUILDING ACCESS CONTROL SYSTEM THE ELECTRICAL CONTRACTOR SHALL RUN ALL REQUIRED CABLING AS DIRECTED AND SHOWN IN DETAILS. ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIELD HARDWARE PROVIDED BY THE DOOR HARDWARE SUPPLIER AND TERMINATE ALL CABLING AT DEVICES AS REQUIRED.COORDINATE TV OUTLET & RECEPTACLE HEIGHT WITH OWNER PRIOR TO ROUGH-IN.PROVIDE 120 VOLT CONNECTION FOR ELECTRIC WATER COOLER. COORDINATE ROUGH-IN WITH PLUMBING CONTRACTOR.PROVIDE 120V POWER CONNECTION TO ELECTRIC FIREPLACE. PROVIDE 2-GANG OUTLET BOX ABOVE DOOR ON SECURE SIDE FOR FUTURE CONNECTION OF SECURITY DEVICES. PROVIDE 3/4" CONDUIT TO DOOR FRAME AND ROUGH (1) 3/4" CONDUIT WITH SINGLE GANG BOX AT 46"AFF IN ACCESSIBLE WALL. PROVIDE BLANK PLATE. PROVIDE 120V CIRCUIT FROM NEAREST EMERGENCY PANEL. COORDINATE FINAL ROUGH-IN LOCATION WITH SECURITY SYSTEM VENDOR.PROVIDE 120V RECEPTACLE AT 48" AFF FOR INTEGRATED WALL SYSTEM. COORDINATE FINAL LOCATION WITH OWNER PRIOR TO ROUGH-IN.PROVIDE 120 VOLT CONNECTION TO POWERED DOOR OPERATOR. PROVIDE ALL REQUIRED CONNECTIONS TO CONTROLS, PUSHPLATES AND INTERLOCKS AS REQUIRED BY MANUFACTURER.PROVIDE RATH SMART RESCUE BASE STATION FOR TWO-WAY COMMUNICATION SYSTEM ADJACENT TO THE FIRE ALARM ANNUNCIATOR. COORDINATE FINAL LOCATION WITH AHJ. EC TO PROVIDE ALL CODE REQUIRED SIGNAGE.ALL TOILET ROOM WATER CLOSETS SHALL HAVE SENSOR OPERATED FLUSH VALVES. ENTIRE SENSOR ASSEMBLY SHALL BE FURNISHED BY THE PLUMBING CONTRACTOR. ELECTRICAL CONTRACTOR SHALL INSTALL ALL DEVICES PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE INSTALLATION WITH PLUMBING CONTRACTOR AND TILE CUTTERS. PROVIDE 120 VOLT CONNECTION AS SHOWN. PROVIDE ALL ADDITIONAL CONDUIT AND WIRING AS REQUIRED TO CONNECT EACH WATER CLOSET. CIRCUIT TO NEAREST RECEPTACLE CIRCUIT.FURNISH DUCT SMOKE DETECTOR FOR INSTALLATION BY MECHANICAL CONTRACTOR. PROVIDE ALL NECESSARY CONNECTIONS AT FIRE ALARM SYSTEM. MAKE CONNECTION AS REQUIRED SUCH THAT DAMPER WILL CLOSE UPON ACTIVATION OF DUCT SMOKE DETECTORN3/16" = 1'-0"1FIRST FLOOR POWER & SYSTEMS PLAN2341/4" = 1'-0"2ENLARGED MAIN SERVER ROOM56789REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 FFFFFFFFFFFF F FFFFFFFFFFFFFFFTVTVTVFFFFFFFFFFFFFFTVFHSSSSSSSSSSSSSSSTVFF FFFFFSSSTVSSSSSSSSFFTVT VM MMMMMMMMMMMMMMMMMMMMMMMMMMMMFMFFFMMRPRPJCRCRJJDHDHENMMMMJJPUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223SBP-2APP2BPP2ADP2EP-2ACORRIDOR232STAIRST2-275110151515153015301515151515 15 151515151515151515151515151515151515151515151515301515RESPITE/LACTATION240STAFFTOILET237MAINLOBBY100RESPITE/MEDITATION241OFFICE238CIRCULATION228DENTALOFFICE230WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203CIRCULATION207NURSE214PHYSICIANOFFICE/DICTATION213LAB221MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204EDUCATION/CONFERENCE234IT/ELEC243ACACAC72"160"1ACAC60"60"1160"ACACACACACACAC AC ACACACACACACACACACACAC160"48"1548"15152AC48"110110AC1548"221103160"STAFFBREAK242RESPITE/LACTATION239STAFFTOILET236STAFFBREAK242ACAC60"ACACAC1548"AC AC75MULTIPURPOSE/ACTIVITY235TELMED233USBUSBUSBUSBUSBUSBPP2B/1PP2B/13PP2A/1PP2B/2PP2A/3PP2B/9DFC-15MDFC-18BDFC-07ODFC-15NDFC-05KDFC-15GDFC-05JDFC-36ADFC-24FDFC-09HDFC-09GDFC-12DDFC-12EDFC-15HDFC-05NDFC-09FDFC-09EDFC-05LDFC-05MDFC-30CDFC-24CDFC-18CPP2A/4PP2A/5AC-18DPP2B/18PP2B/16PP2B/14PP2A/13PP2B/22PP2B/23PP2B/24PP2B/15PP2A/17PP2A/23PP2A/24SBP-2A/5PP2A/26PP2A/27PP2B/21PP2A/28PP2B/5PP2A/33PP2A/34PP2A/35PP2A/36PP2A/7PP2A/2PP2A/6PP2A/8PP2A/29PP2A/14BS-16BS-17BS-15BS-19PROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIES, TO 3RD FLOORPROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIES1AC ACPP2B/6PP2B/8PP2B/10PP2B/11PP2B/12ACAC15BS-1815PP2A/19PP2A/7BS-20PP2B/3PP2A/32PP2A/31HWH-1BHWRP-1BPP2A/37DFC-24DPP2A/22PP2A/18PP2A/20PP2B/4ACBS-21PP2A/151PP2B/17PP2B/19PP2A/16PP2A/25PP2B/20PP2A/30PP2A/10PP2A/1248"48"48"48"444448"448"448"448"4PP2A/215SBP-2A/1L6-30R TWISTLOCK(TYP OF 2)SBP-2A/8,10SBP-2A/2SBP-2A/7,9PP2A/9GROUND BARPP1B/186EP-2A/1667EP-2A/1EP-2A/1SBP-2A/37SBP-2A/4BS-22BF-1BCUH-1CLCP-2SBP-2A/688888891011PP2B/47PP2B/48SD12SD12SD12SD12SD12SD12SD12SD12SD12PP2B/4913803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:56:32 PME102SECONDFLOOR POWER& SYSTEMSPLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1SECOND FLOOR POWER & SYSTEMS PLANDRAWING NOTES:1GENERAL NOTES:A. REFER TO DRAWING E101 FOR GENERAL NOTES.COORDINATE TV OUTLET & RECEPTACLE HEIGHT WITH OWNER PRIOR TO ROUGH-IN.PROVIDE 120 VOLT CONNECTION FOR ELECTRIC WATER COOLER. COORDINATE ROUGH-IN WITH PLUMBING CONTRACTOR.PROVIDE 4'x8'x3/4" FIRE TREATED PLYWOOD BACKBOARD. PAINT GRAY.PROVIDE 120V RECEPTACLE AT 48" AFF FOR INTEGRATED WALL SYSTEM. COORDINATE FINAL LOCATION WITH OWNER PRIOR TO ROUGH-IN.PROVIDE RECESSED FIRE-RATED POKE THROUGH SUITABLE FOR CONCRETE POUR WITH 50/50 DEVICE PLATES, (2) 20A DUPLEX RECEPTACLES AND DECORATOR PLATE FOR FUTURE DATA DEVICES. PROVIDE COVERPLATES AND COVER WITH HIDE AWAY EGRESS DOOR WHILE IN USE. PROVIDE (1)2" CONDUIT AND (1) 3/4"CONDUIT TO BELOW FLOOR TO PANEL SHOWN. POKETHROUGH SHALL BE EQUAL TO HUBBELL SYSTEMONE RECESSED FRPT FOR 6" CORE. COORDINATE EXACT REQUIREMENTS WITH ARCHITECT.PROVIDE 2-GANG OUTLET BOX ABOVE DOOR ON SECURE SIDE FOR FUTURE CONNECTION OF SECURITY DEVICES. PROVIDE 3/4" CONDUIT TO DOOR FRAME AND ROUGH (1) 3/4" CONDUIT WITH SINGLE GANG BOX AT 46"AFF IN ACCESSIBLE WALL. PROVIDE BLANK PLATE. PROVIDE 120V CIRCUIT FROM NEAREST EMERGENCY PANEL. COORDINATE FINAL ROUGH-IN LOCATION WITH SECURITY SYSTEM VENDOR.PROVIDE 120 VOLT CONNECTION TO POWERED DOOR OPERATOR. PROVIDE ALL REQUIRED CONNECTIONS TO CONTROLS, PUSHPLATES AND INTERLOCKS AS REQUIRED BY MANUFACTURER.ALL TOILET ROOM WATER CLOSETS SHALL HAVE SENSOR OPERATED FLUSH VALVES. ENTIRE SENSOR ASSEMBLY SHALL BE FURNISHED BY THE PLUMBING CONTRACTOR. ELECTRICAL CONTRACTOR SHALL INSTALL ALL DEVICES PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE INSTALLATION WITH PLUMBING CONTRACTOR AND TILE CUTTERS. PROVIDE 120 VOLT CONNECTION AS SHOWN. PROVIDE ALL ADDITIONAL CONDUIT AND WIRING AS REQUIRED TO CONNECT EACH WATER CLOSET. CIRCUIT TO NEAREST RECPETACLE CIRCUIT.PROVIDE 120V POWER CONNECTION TO DENTAL CHAIR. COORDINATE LOCATION AND ELECTRICAL REQUIREMENTS WITH OWNERS REP PRIOR TO ROUGH-IN.PROVIDE (2) 2" CONDUITS BELOW FLOOR TO DENTAL CHAIR. CONDUIT TO HAVE NO 90 DEGREE ANGLES. PROVIDE PULL-STRING IN CONDUIT, FINISH AND CAP.PROVIDE 120V POWER CONNECTION TO CEILING MOUNTED DENTAL LIGHT. COORDINATE ELECTRICAL REQUIREMENTS AND LOCATION WITH EQUIPMENT PROVIDER PRIOR TO ROUGH-IN.FURNISH DUCT SMOKE DETECTOR FOR INSTALLATION BY MECHANICAL CONTRACTOR. PROVIDE ALL NECESSARY CONNECTIONS AT FIRE ALARM SYSTEM. MAKE CONNECTION AS REQUIRED SUCH THAT DAMPER WILL CLOSE UPON ACTIVATION OF DUCT SMOKE DETECTOR.EXTERIOR SIGNAGE TO BE CONTROLLED BY TIMECLOCK VIA LIGHTING CONTROL SYSTEM. SEE DETAILS FOR MORE INFORMATION.234567FTS8910111213REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 FFFFSTVFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFSSSSSSSSSSSSSSSSSSSSSSSSSTVMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMFMMMMMMFMMRPRPMDHJFFFFFFFFFFENENMENMNEEMMMMMMEELEC/DATA323PP3BPP3ADP3EP-3ASBP-3ASTAIRST2-2NURSEWORKAREA317BSTAIR1ST1-3151548"48"48"1521AC AC ACAC AC ACACACACACAC ACACACAC ACAC48"ACACACAC AC ACACACACACACACACACACACAC60"AC AC48"60"3AC15751515151515153015151515151515151515151515151515151515151515151515 151515151515751515GUESTWAITING/CIRCULATION300PUBLICTOILET300APUBLICTOILET300BREGISTRATION301STAFFTOILET305AOFFICEMANAGER301APATIENTTOILET302SPECIALTYEXAM/TREATMENT303STAFFBREAKAREA305EXAM/CONSULT306EXAM/CONSULT307PROVIDEROFFICE317AEXAM/CONSULT308EXAM/CONSULT309CENTRALSOILEDWORK311PATIENTVITALSALCOVE310CENTRALCLEANWORK312EXAM/CONSULT313EXAM/CONSULT314EXAM/CONSULT315EXAM/CONSULT316EXAM/CONSULT318CIRCULATION304EXAM/CONSULT319EXAM/CONSULT320EXAM/CONSULT321EXAM/CONSULT322SPECIMENCOLLECTION333LABDRAW332LAB334PATIENTTOILET335ASPECIALTYEXAM/TREATMENT/TELEMED335PATIENTTOILET336TRIAGENURSE339BEXAM/CONSULT327EXAM/CONSULT328EXAM/CONSULT331TRIAGENURSE324PROVIDEROFFICE317FNURSEWORKAREA317EPROVIDEROFFICE339AEXAM/CONSULT328EXAM/CONSULT329PATIENTTOILET327SPECIALTYEXAM/TREATMENT326STAFFTOILET325PATIENTTOILET326A15ACACACACACACACUSBUSBUSB1530ACAC ACUSBUSBUSBUSBUSBUSB4ACACACUSBNURSEWORK339PP3A/8PP3A/6PP3A/5PP3A/9PP3A/4PP3A/3PP3A/2PP3A/1USBPP3A/11PP3A/10SBP-3A/2PP3B/29PP3B/28PP3B/27PP3B/26PP3A/13PP3A/14PP3A/16PP3A/15PP3A/17PP3A/18PP3A/19PP3A/25PP3A/21PP3B/17PP3B/19PP3B/20PP3B/25PP3B/24PP3B/23PP2B/7PP3B/21PP3B/16PP3A/23PP3A/20PP3A/24PP3A/27PP3A/26PP3A/28SBP-3A/4PP3A/30SBP-3A/3PP3A/31PP3A/32PP3A/33PP3A/34PP3A/35PP3B/12PP3B/11PP3B/13PP3A/37PP3B/14PP3A/38PP3A/39PP3A/40PP3A/41PP3A/42PP3B/7PP3B/7PP3B/6PP3B/4PP3B/5PP3B/15SBP-3A/6SBP-3A/5PP3B/3PP3A/7DFC-18LDFC-36CDFC-05AUDFC-05AVDFC-12PDFC-12QDFC-05AZDFC-05BBDFC-05AXDFC-05BADFC-05AYDFC-15ODFC-05BCDFC-09ODFC-05BEDFC-05BFDFC-18IDFC-05BGDFC-05BHDFC-07MDFC-05BJDFC-05BIDFC-09QDFC-05BDDFC-05AWDFC-05ARDFC-05ASDFC-05ATDFC-18JDFC-07LDFC-09PDFC-18KPP3B/2PP3B/22PROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIES, TO 4TH FLOORSBP-3A/1SBP-3A/7PROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIES1548"548"5BS-24PP3A/29STORAGE35048"48"48"555BS-2348"5PP3A/3648"48"48"48"48"48"48"48"48"55555555548"48"48"48"5555PP3B/848"3BS-25PP3B/9BS-28BS-27ACPP3B/10PP3A/12PP3B/1BS-3015PP3A/22BS-29AC-18EGROUND BARL6-30R TWISTLOCK(TYP OF 2)SBP-3A/9,11SBP-3A/8,10PP3B/1848"5CUH-1BEP-3A/1615151515151515151515BS-26BF-1CHWRP-1CHWH-1CAC-24CCUH-1DFTSLCP-377777777SD8SD8SD8SD8SD8803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:56:43 PME103THIRD FLOORPOWER &SYSTEMS PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1THIRD FLOOR POWER & SYSTEMS PLANDRAWING NOTES:1GENERAL NOTES:A. REFER TO DRAWING E101 FOR GENERAL NOTES.PROVIDE 4'x8'x3/4" FIRE TREATED PLYWOOD BACKBOARD. PAINT GRAY.PROVIDE 120 VOLT CONNECTION FOR ELECTRIC WATER COOLER. COORDINATE ROUGH-IN WITH PLUMBING CONTRACTOR.COORDINATE TV OUTLET & RECEPTACLE HEIGHT WITH OWNER PRIOR TO ROUGH-IN.PROVIDE 120V POWER CONNECTION TO ELECTRIC FIREPLACE. PROVIDE 120V RECEPTACLE AT 48" AFF FOR INTEGRATED WALL SYSTEM. COORDINATE FINAL LOCATION WITH OWNER PRIOR TO ROUGH-IN.PROVIDE 2-GANG OUTLET BOX ABOVE DOOR ON SECURE SIDE FOR FUTURE CONNECTION OF SECURITY DEVICES. PROVIDE 3/4" CONDUIT TO DOOR FRAME AND ROUGH (1) 3/4" CONDUIT WITH SINGLE GANG BOX AT 46"AFF IN ACCESSIBLE WALL. PROVIDE BLANK PLATE. PROVIDE 120V CIRCUIT FROM NEAREST EMERGENCY PANEL. COORDINATE FINAL ROUGH-IN LOCATION WITH SECURITY SYSTEM VENDOR.ALL TOILET ROOM WATER CLOSETS SHALL HAVE SENSOR OPERATED FLUSH VALVES. ENTIRE SENSOR ASSEMBLY SHALL BE FURNISHED BY THE PLUMBING CONTRACTOR. ELECTRICAL CONTRACTOR SHALL INSTALL ALL DEVICES PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE INSTALLATION WITH PLUMBING CONTRACTOR AND TILE CUTTERS. PROVIDE 120 VOLT CONNECTION AS SHOWN. PROVIDE ALL ADDITIONAL CONDUIT AND WIRING AS REQUIRED TO CONNECT EACH WATER CLOSET. CIRCUIT TO NEAREST RECPETACLE CIRCUIT.FURNISH DUCT SMOKE DETECTOR FOR INSTALLATION BY MECHANICAL CONTRACTOR. PROVIDE ALL NECESSARY CONNECTIONS AT FIRE ALARM SYSTEM. MAKE CONNECTION AS REQUIRED SUCH THAT DAMPER WILL CLOSE UPON ACTIVATION OF DUCT SMOKE DETECTOR2345678REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 FFFFFFFFFFFFFF FFFFFFTVFFFFFFFFFFFTVFFFFFFFFFFFFFFFFFSSSSSSSSSSSSSSSSSSSFFFFFFFSSSSSSSSSSSSSSSSSSFSSFFTVTVMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMTVRPRPJDHEMNEEEENNNNNMMPATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445PP4BPP4ADP4SBP-4AEP-4ASTAIRST2-2STAIR1ST1-3EVS4391515151515151515151515 15 1515 1515151515151515151515151515151515151575303015151515151515151515PROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438PROCEDUREROOM440RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402WOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418ACIRCULATION412HOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS417260"1ACACACACACACACACACAC48"ACAC72"148"ACACACACACACACACACACACAC48"ACACACACACACACACACACAC2AC1515151575151548"AC3154USBUSB USBUSBUSBUSBUSBUSBUSBUSB15USB USBUSBDFC-12HDFC-15LDFC-12IDFC-07FDFC-05SDFC-05QDFC-05TDFC-12FDFC-12GDFC-18EDFC-09IDFC-05ODFC-07EDFC-15JDFC-30BDFC-15IDFC-05PDFC-05AODFC-07NDFC-07IDFC-07QDFC-12JDFC-07PDFC-12LDFC-12KDFC-05XDFC-05UDFC-12SDFC-09JPP4A/2AC-18GPP4B/2PP4B/3PP4B/6PP4B/5PP4A/3PP4B/8PP4B/12PP4A/5PP4A/4PP4A/6PP4A/9PP4A/8PP4A/11PP4A/11PP4A/13PP4A/14PP4A/16PP4A/18DFC-15KPP4A/19PP4A/20PP4A/21PP4A/17PP4A/22SBP-4A/9SBP-4A/33PP4A/23DFC-07HPP4A/26PP4A/24PP4A/25PP4B/11SBP-4A/34SBP-4A/35SBP-4A/15SBP-4A/8SBP-4A/8USBSBP-4A/7SBP-4A/5SBP-4A/4SBP-4A/13SBP-4A/14SBP-4A/16PROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIES, TO 5TH FLOORPROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIESSBP-4A/17SBP-4A/18 SBP-4A/20SBP-4A/19 SBP-4A/21SBP-4A/22ACACPP4A/27PP4B/105BS-36BS-341BS-31BS-33BS-32BS-37HWH-1DHWRP-1DBS-35PP4A/29BS-39AC-18FGROUND BARSBP-4A/24PP4B/1?L6-30R TWISTLOCK(TYP OF 2)L6-30R TWISTLOCK(TYP OF 2)PP4A/1SBP-4A/30,32SBP-4A/29,31SBP-4A/26,28SBP-4A/25,27BS-41BS-42PP4B/4BS-40ACPP4B/7PP4B/9PP4B/20BS-38PP4B/14PP4B/13RESULTSALCOVE410WOMEN'SSUB-WAIT409PP4A/10PP4B/1554"1DFC-05RACACPP4B/17PP4B/16PP4A/7PP4A/28PP4A/15PP4B/18PP4A/176EP-4A/17SBP-4A/27SBP-4A/3PP4B/192E6031E6031E602UnoccupiedUnoccupiedSBP-4A/23PP4A/12BF-1DFTSLCP-488888888888SD9SD9SD9SD9SD9803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:56:54 PME104FOURTHFLOOR POWER& SYSTEMSPLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FOURTH FLOOR POWER & SYSTEMS PLANDRAWING NOTES:1GENERAL NOTES:A. REFER TO DRAWING E101 FOR GENERAL NOTES.COORDINATE TV OUTLET & RECEPTACLE HEIGHT WITH OWNER PRIOR TO ROUGH-IN.PROVIDE 120 VOLT CONNECTION FOR ELECTRIC WATER COOLER. COORDINATE ROUGH-IN WITH PLUMBING CONTRACTOR.PROVIDE 4'x8'x3/4" FIRE TREATED PLYWOOD BACKBOARD. PAINT GRAY.PROVIDE 120V POWER CONNECTION TO ELECTRIC FIREPLACE. PROVIDE 1KVA ISOLATION TRANSFORMER(GE LU8544) AND SINGLE PHASE ENCLOSED CIRCUIT BREAKER (GE THQL1115). COORDINATE INSTALLATION WITH EQUIPMENT MANUFACTURER.PROVIDE 2-GANG OUTLET BOX ABOVE DOOR ON SECURE SIDE FOR FUTURE CONNECTION OF SECURITY DEVICES. PROVIDE 3/4" CONDUIT TO DOOR FRAME AND ROUGH (1) 3/4" CONDUIT WITH SINGLE GANG BOX AT 46"AFF IN ACCESSIBLE WALL. PROVIDE BLANK PLATE. PROVIDE 120V CIRCUIT FROM NEAREST EMERGENCY PANEL. COORDINATE FINAL ROUGH-IN LOCATION WITH SECURITY SYSTEM VENDOR.PROVIDE 120 VOLT CONNECTION TO POWERED DOOR OPERATOR. PROVIDE ALL REQUIRED CONNECTIONS TO CONTROLS, PUSHPLATES AND INTERLOCKS AS REQUIRED BY MANUFACTURER.ALL TOILET ROOM WATER CLOSETS SHALL HAVE SENSOR OPERATED FLUSH VALVES. ENTIRE SENSOR ASSEMBLY SHALL BE FURNISHED BY THE PLUMBING CONTRACTOR. ELECTRICAL CONTRACTOR SHALL INSTALL ALL DEVICES PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE INSTALLATION WITH PLUMBING CONTRACTOR AND TILE CUTTERS. PROVIDE 120 VOLT CONNECTION AS SHOWN. PROVIDE ALL ADDITIONAL CONDUIT AND WIRING AS REQUIRED TO CONNECT EACH WATER CLOSET. CIRCUIT TO NEAREST RECPETACLE CIRCUIT.FURNISH DUCT SMOKE DETECTOR FOR INSTALLATION BY MECHANICAL CONTRACTOR. PROVIDE ALL NECESSARY CONNECTIONS AT FIRE ALARM SYSTEM. MAKE CONNECTION AS REQUIRED SUCH THAT DAMPER WILL CLOSE UPON ACTIVATION OF DUCT SMOKE DETECTOR23456789REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFTVFFFFFFFFFFFFFFFFFSSSSSSSSSSSSSSSHMSHMFFFFFSSSSSSSSSSFFSHECECECECSFSSTVMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMFMMMJHRPRPDHJFFFFFFFFSEENNMMNEENMENMMMMMEXAM/CONSULT521EXAM/CONSULT507EXAM/CONSULT513EXAM/CONSULT522PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529EXAM/CONSULT531CIRCULATION504SPECIALTYEXAM/TREATMENT526PATIENTTOILET527PATIENTTOILET526ASTAFFTOILET525STAFFCIRCULATION517EXAM/CONSULT520EXAM/CONSULT514EXAM/CONSULT519EXAM/CONSULT515EXAM/CONSULT518EXAM/CONSULT516CIRCULATION504BBNURSEWORKAREA517BEXAM/CONSULT509EXAM/CONSULT508SPECIALTYEXAM/TREATMENT506CIRCULATION517DPROVIDEROFFICE517ANURSEWORKAREA517ETRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FREGISTRATION502OFFICEMANAGER502APATIENTTOILET503STAFFBREAKAREA505STAIR3ST3-5STAIRVESTIBULE504ASTAFFTOILET505APUBLICTOILET501APUBLICTOILET501BELEVA500EAELEVB500EBELEVATORCONTROLROOM500LAB534LABDRAW532SPECIMENCOLLECTION533TRIAGENURSE539BPATIENTTOILET536STAIR1ST1-5PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535EXAM/CONSULT537PP5BPP5ADP5EP-5ASBP-5ACENTRALSOILEDWORK511PATIENTVITALSALCOVE510STAIRST2-2TOP OFSHAFT3ELEV FIRE HATELEVFIRE HAT4315151515151515151530151515110151515151515153015151515151515151515151515151515151515151560"1ACAC2ACACAC48"ACACACACACACACACAC ACACACAC ACACACACACACACACACACACACACACACACACACAC48"2ACACACAC151515155GUESTWAITING/CIRCULATION501ACAC151548"WPWPELEV-BELEV-AELEV CAPTURE46USBUSB USBUSBUSBUSBUSBUSBACACACACACACACACACACAC1515DFC-18HDFC-36BAC-18IDFC-05ABDFC-05ACDFC-18FDFC-05ZDFC-05YDFC-07JDFC-05AADFC-05APDFC-05AMDFC-12NDFC-18GDFC-05AEDFC-05ADDFC-05AGDFC-09LDFC-05AIDFC-05ALDFC-09NAC-18HDFC-05ANDFC-09KDFC-09MDFC-05AKDFC-05AJDFC-05AHDFC-18MDFC-07GDFC-05AFDFC-15PPP5A/1PP5B/41PP5A/3PP5A/4PP5A/5PP5A/5PP5A/5PP5B/37PP5B/36PP5B/29PP5A/6PP5A/7PP5A/8PP5A/9PP5A/10PP5B/8PP5B/30PP5A/13PP5A/14PP5A/15DFC-12OPP5B/31PP5B/32PP5B/33PP5A/16PP5A/17PP5B/22PP5B/23EXAM/CONSULT538PP5B/25PP5B/24PP5A/18PP5A/21PP5A/20PP5A/22PP5A/23EVS530PP5A/24CENTRALCLEANWORK512DFC-05AQPP5A/25PP5B/34PP5B/35PP5A/26PP5A/26PP5A/28PP5B/39PP5B/38CIRCULATION504PP5B/11SBP-5A/4SBP-5A/3PP5B/27PP5A/31SBP-5A/9PP5A/33PP5A/34PP5A/37PP5A/36PP5A/38PP5A/39PP5A/40PP5A/41PP5A/42PP5B/1PROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIES, TO 4TH FLOORPROVIDE (4) 4" HILTI FIRESTOP SPEED SLEEVES, CP 653 SERIESGROUND BARL6-30R TWISTLOCK(TYP OF 2)SBP-5A/1SBP-5A/5,7SBP-5A/6,8PP5A/12BS-49BS-50PP5B/2848"7748"48"48"48"48"777748"48"48"48"7777PP5A/11PP5A/29PP5A/30BS-47PP5B/2BS-46BS-45SBP-5A/2PP5A/35PP5B/9PP5B/10748"PP5B/1248"715BS-4448"48"48"777PP5B/26PP5B/1348"48"77HWH-1EHWRP-1E1PP5A/264"PP5B/14PP5B/15PP5B/16PROVIDE JUNCTION BOX ABOVE CEILING FOR SIGNAGE REMOTE POWER SUPPLIES, BY OTHERS, 4 TOTAL. PROVIDE 120V POWER CONNECTION TO LED DRIVERS. COORDINATE FINAL REQUIREMENTS WITH EXTERIOR SIGNAGE VENDOR PLANS.PP5B/17PP5A/192PP5B/20EP-5A/191515151515151515BS-48PP5B/21PP5B/40BS-43BF-1EAC-24BBDA UNITEP-5A/6EP-5A/5LCP-5101010101010101010SD11SD11SD11SD11SD11803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:57:06 PME105FIFTH FLOORPOWER &SYSTEMS PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FIFTH FLOOR POWER & SYSTEMS PLANDRAWING NOTES:1GENERAL NOTES:A. REFER TO DRAWING E101 FOR GENERAL NOTES.COORDINATE TV OUTLET & RECEPTACLE HEIGHT WITH OWNER PRIOR TO ROUGH-IN.PROVIDE 120 VOLT CONNECTION FOR ELECTRIC WATER COOLER. COORDINATE ROUGH-IN WITH PLUMBING CONTRACTOR.PROVIDE 120V, 30A, FUSED, NEMA 3R LOCKABLE DISCONNECT WITH AUXILLARY CONTACTS FOR ELEVATOR CAB LIGHTS.PROVIDE 208V, 3 PHASE, 100A FUSED, NEMA 3R, LOCKABLE DISCONNECT WITH AUXILLARY CONTACTS FOR ELEVATOR. REFER YO ELECTRICAL EQUIPTMENT AND CONTROL SCHEDULE FOR FEEDER INFORMATION. EC TO VERIFY FINAL ELEVATOR REQUIREMENTS PRIOR TO PURCHASE AND ROUGHIN PER ELEVATOR SUBMITTAL. CONTRACTOR SHALL MAKE ALL NECESSARY CHANGES. PROVIDE 4'x8'x3/4" FIRE TREATED PLYWOOD BACKBOARD. PAINT GRAY.PROVIDE 120V POWER CONNECTION TO ELECTRIC FIREPLACE. PROVIDE 120V RECEPTACLE AT 48" AFF FOR INTEGRATED WALL SYSTEM. COORDINATE FINAL LOCATION WITH OWNER PRIOR TO ROUGH-IN.NOT USED.PROVIDE 2-GANG OUTLET BOX ABOVE DOOR ON SECURE SIDE FOR FUTURE CONNECTION OF SECURITY DEVICES. PROVIDE 3/4" CONDUIT TO DOOR FRAME AND ROUGH (1) 3/4" CONDUIT WITH SINGLE GANG BOX AT 46"AFF IN ACCESSIBLE WALL. PROVIDE BLANK PLATE. PROVIDE 120V CIRCUIT FROM NEAREST EMERGENCY PANEL. COORDINATE FINAL ROUGH-IN LOCATION WITH SECURITY SYSTEM VENDOR.ALL TOILET ROOM WATER CLOSETS SHALL HAVE SENSOR OPERATED FLUSH VALVES. ENTIRE SENSOR ASSEMBLY SHALL BE FURNISHED BY THE PLUMBING CONTRACTOR. ELECTRICAL CONTRACTOR SHALL INSTALL ALL DEVICES PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE INSTALLATION WITH PLUMBING CONTRACTOR AND TILE CUTTERS. PROVIDE 120 VOLT CONNECTION AS SHOWN. PROVIDE ALL ADDITIONAL CONDUIT AND WIRING AS REQUIRED TO CONNECT EACH WATER CLOSET. CIRCUIT TO NEAREST RECPETACLE CIRCUIT.FURNISH DUCT SMOKE DETECTOR FOR INSTALLATION BY MECHANICAL CONTRACTOR. PROVIDE ALL NECESSARY CONNECTIONS AT FIRE ALARM SYSTEM. MAKE CONNECTION AS REQUIRED SUCH THAT DAMPER WILL CLOSE UPON ACTIVATION OF DUCT SMOKE DETECTOR23456789FTS1011REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMSDSDSDFFMMMJJMMMMDOAS-1DOAS-3DOAS-2ACCU-1EACCU-1NACCU-2EACCU-2NACCU-3EACCU-3NACCU-4EACCU-4NACCU-5EACCU-5NACCU-1WACCU-2WACCU-3WACCU-4WACCU-5WACCU-5SACCU-4SACCU-3SACCU-2SACCU-1SSTAIR2S600CU-18FCU-18ECU-18DCU-18CCU-18BCU-18AFSDFSDFSD15111WPWPWPCU-18GCU-18HCU-18IWPWP11PP5B/3PP5B/4PP5B/7PP5B/5PROVIDE JUNCTION BOX BEHIND ACCESS PANEL FOR SIGNAGE REMOTE POWER SUPPLIES, BY OTHERS, 4 TOTAL. PROVIDE 120V POWER CONNECTION TO LED DRIVERS. COORDINATE FINAL REQUIREMENTS WITH EXTERIOR SIGNAGE VENDOR PLANS.PP5B/18PP5B/6PROVIDE JUNCTION BOX BEHIND ACCESS PANEL FOR SIGNAGE REMOTE POWER SUPPLIES, BY OTHERS, 4 TOTAL. PROVIDE 120V POWER CONNECTION TO LED DRIVERS.COORDINATE FINAL REQUIREMENTS WITH EXTERIOR SIGNAGE VENDOR PLANS.PP5B/1922EF-1560CU-48ACU-24AAC-24AWP1WPWPWPPP5A/53PP5A/54PP5A/55333803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:57:15 PME106ROOF PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1ROOF PLANDRAWING NOTES:1GENERAL NOTES:A. REFER TO DRAWING E101 FOR GENERAL NOTES.PROVIDE 120V GFI RATED RECEPTACLE IN WEATHER PROOF ENCLOSURE WITH 'IN-USE' COVER.EXTERIOR SIGNAGE TO BE CONTROLLED BY TIMECLOCK VIA LIGHTING CONTROL SYSTEM. SEE DETAILS FOR MORE INFORMATION.PROVIDE 120V GFI RATED RECEPTACLE IN WEATHER PROOF ENCLOSURE WITH 'IN-USE' COVER AT PARAPET ACCESS PANEL. COORDINATE FINAL LOCATION WITH ARCHITECT.23REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.ATSATSOSOSOSOSOSOS33DDDDOSOSOSO S OSDDDD OSDOSDOSDDDDDDOSDDDDDDOSOSOS3333VSOSOSVSDDOSOSOSOSDDDD DOSOSOSOSO S OSOSOSDOSOSOSDOSOSOSOSOSOSOSOSDDOSOSDCORRIDOR122HOLDING/MAIL100CVITALSALCOVE105ACIRCULATION105CIRCULATION105CIRCULATION105SUB-WAITING105BLILILILILILILILILILILILILILILILILILILILILALALULULULULULULALALALNLKLALALALNLNLNLHLHLHLHCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEVS109EXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CSPECIMENTOILET127STAIR2ST2-1BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125RADIOLOGY(X-RAY)119CORRIDOR143TREATMENT117EXAM113CLEANHOLDING107SHAREDPROVIDEROFFICE104STAFFBREAK102BUILDINGMAINTENANCETOILET/SHOWER138APP1BPP1ADP1EP-1ASBP-1AGDPATS-EMEMDPSBDPATS-SBMDPMECHANICAL145LHLHSTATLAB/MED110PUBLICTOILET100BAIN PITIN PITLKLALALNLILALDLDLDLALALALALALDLDLDLDLDLDLDLDLDLDLALALALALALALALALALHLHLHLHLHLDLALALALALDLDLDLDLDLNLNLILILILILILILILILILILILILILILILILULULALALALELELELELILNLNLNLNLNLNLNLNLILILILILALALALALALALALALELULULILILILILNLNLELALELALELFLFLFLFLILILILILILILILILILILNLNLNLNLNLNLNLNLNLELELELELELELILBLBLBLBLQLQLQXLCXLCLQLQLQLRLRLRLRLRLRXLAXLAXLAXLAXLBDDWPWPLWLALYLZLZLZLZLZLZLELEEMEMX1LNLNX1X1X1X1LILILIX1LFX1X1X1X1EMEMX1LNX1X1X1X1X1EMEMX1X1X1EMEMEMEMEMEMEM/NLEM/NLEM/NLEM/NLEMX1EMEMEMccaaaabbbba,b,c,d,e,f,gedddddggggEMga,b,c,d,e,fEMEM EMLHdddd dEMEMccEMEMEMaa aa,c,dEMddEM1EM1EM1EM1ddd ddddddddddddddddddEM EM EM EMEMEMEM EMEMbbbbbbbbbEMEMEMccEMEMbbbbbbbaaaaaaaaaa,b,c,dEMaabbbbdddddddddeeeeffffffEMEMEMEMEM111PP1B/5EM1EP-1A/2EP-1A/2EP-1A/2EP-1A/2EP-1A/2EP-1A/2EP-1A/2EP-1A/2EP-1A/2EP-1A/2EP-1A/21122211111EP-1A/2EP-1A/2EP-1A/2EP-1A/21112EP-1A/2EP-1A/2EP-1A/21EP-1A/211111PP1B/5EP-1A/2EP-1A/2PP1B/7EP-1A/5SBP-1A/57SBP-1A/58EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10 EP-1A/10EP-1A/10 EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/10EP-1A/1011111111121111112211EP-1A/102SBP-1A/59SBP-1A/59SBP-1A/59111111EP-1A/11EP-1A/112221g1EP-1A/11EP-1A/11EP-1A/11EP-1A/11EMEP-1A/11EP-1A/1111h,jPP1B/92OPEN TO ABOVEiPP2B/25LSLSEMEM22EP-1A/14EMEP-1A/15XLAEMXLAEMXLAEMLQcEMXLCEMcdgEMEP-1A/5APP1B/533333333333111803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:57:28 PME201FIRST FLOORLIGHTING PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIRST FLOOR LIGHTING PLANGENERAL NOTES:A. INSTALL CONDUIT PERPENDICULAR, PARALLEL, AND TIGHT TO STRUCTURE, COLUMNS AND BEAMS. COORDINATE EXPOSED CONDUIT ROUTING WITH ARCHITECT AND ENGINEER. B. LABEL CONDUIT PER SPECIFICATION.C. PROVIDE TYPE WRITTEN PANELBOARD SCHEDULES FOR ALL PANELS.D. PROVIDE BLANK COVERPLATES ON ALL UNUSED OUTLET BOXES.E. COORDINATE ALL CONDUIT RUNS WITH OTHER TRADES PRIOR TO ROUGH-IN.F. REFER TO ARCHITECTURAL ELEVATIONS FOR DEVICE LOCATION AND MOUNTING HEIGHT PRIOR TO ROUGH-IN.G. FIRESTOP ALL PENETRATIONS THROUGH FIRE AND SMOKE WALLS. H. ALL WIRING SHALL BE PLENUM RATED.I. FOR ALL NEW BUILDING MOUNTED EXTERIOR LIGHTS ROUTE CONDUIT INSIDE BUILDING AND POKETHROUGH TO MAKE CONNECTION TO FIXTURES ON BUILDING EXTERIOR. UTILIZE #10 AWG FOR ALL EXTERIOR LIGHTING CIRCUITS. EXTERIOR FIXTURES TO BE SWITCHED BY TIMECLOCK/PHOTOCONTROL VIA LIGHTING CONTACTOR.J. CONNECT ALL EMERGENCY LIGHT AND EXIT LIGHT TYPES, EM1 AND X1, TO LOCAL LIGHTING CIRCUIT AHEAD OF ANY SWITCHING.K. CONNECT ALL EMERGENCY LUMINAIRES WITH 'EM' ADJACENT TO FIXTURE OR WITH HATCHING TO PANEL SHOWN. UTILIZE #10 AWG FOR EMERGENCY LIGHTING CIRCUIT. PROVIDE RED LABEL ON FIXTURE NOTING CIRCUIT AND CIRCUIT NUMBER.L. CONNECT ALL LUMINAIRES WITH 'EM/NL' ADJACENT TO FIXTURE TO PANEL SHOWN. UTILIZE #10 AWG FOR EMERGENCY LIGHTING CIRCUIT. PROVIDE RED LABEL ON FIXTURE NOTING CIRCUIT AND CIRCUIT NUMBER. FIXTURES SHALL BE UNSWITCHED. FIXTURES SHALL ACT AS NIGHT LIGHTS AND EMERGENCY EGRESS LIGHTING.M. CIRCUIT STAIR 1 LIGHTS TO PANEL EP-1A/12.N. CIRCUIT STAIR 2 LIGHTS TO PANEL EP-1A/13.DRAWING NOTES:FIXTURE SHALL BE USED AS EMERGENCY. FIXTURE TO BE CIRCUITED AS SHOWN AND SWITCHED, IN TANDEM WITH NORMAL CIRCUIT VIA UL 924 LISTED AUTOMATIC LIGHTING CONTROL RELAY. SEE TANDEM NORMAL/EMERGENCY SWITCHING DETAIL.PROVIDE UL 924 LISTED AUTOMATIC LOAD CONTROL RELAY FOR OPERATION OF EMERGENCY LIGHTING FIXTURES DURING NORMAL POWER FAILURE, REGARDLESS OF CONTROL POSITION. SEE EMERGENCY SWITCHING DETAIL.FIXTURE SHALL BE USED FOR EMERGENCY EGRESS. CIRCUIT VIA AUTOMATIC LOAD CONTROL RELAY TO ALLOW FOR BYPASS OF ALL SWITCHING DURING LOSS OF NORMAL POWER. NORMAL SENSING CIRCUIT SHALL TIE INTO EXTERIOR LIGHTING BRANCH CIRCUIT SHOWN AHEAD OF SWITCHING. DEVICE SHALL BE MOUNTED ABOVE CEILING. REFER TO DETAIL SHEETS FOR MORE INFORMATION.123REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 DDDOSOSDDDDDOSOSD D DD D OSDDDD D D DDDDDDDDDDDOSOSDDDOSDO S OSVSOSOSVSVSVSVSVSOSVSVSOSVSOSOSVSVSDDDDDDD D DVSVSOSOSDDDOSOSOSOSOSDDDDDOSOSOSOSOSOSDDVSD D LALULULULULALULULALALALALULULULALALDLILULILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILNLNLNLNLNLALALNLNLNLNLILILILILILILILILILILILILILKLKLNLNLNLILALNLILILIPUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223RESPITE/LACTATION240STAFFTOILET237CORRIDOR232STAIRST2-2RESPITE/MEDITATION241OFFICE238CIRCULATION228DENTALOFFICE230WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203CIRCULATION207NURSE214PHYSICIANOFFICE/DICTATION213LAB221MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204EDUCATION/CONFERENCE234IT/ELEC243LILILILILNLELELELNLNLNLNLELNLNLNLALALILILILILILILILILILELELELPLILILILILILILILILILILILILILILILILILILILILILILELELELELTLTLILILILILILILILTLTLILILILILILILILELELILILILILILILILILILILILILILILNLNLNLELILILILILILILILILILILILILNLNLNLNLEPROVIDE TEMPORARY CONSTRUCTION LIGHTING IN THIS AREA FOR A MINIMUM OF 2FC AT FINISHED FLOOR.EP-2ASBP-2APP2BPP2ADP2LHLHSTAFFBREAK242LXLCLCLZLZLZLZLZLZLZLZLZLZLZLZLZX1EMRESPITE/LACTATION239STAFFTOILET236EMX1X1X1X1X1X1X1X1X1X1X1X1X1X1X1EMEMLNLNLALAX1X1X1LMLILIEM1EM1EM1EM1EM1EM1EM1EMEMEMEM EM EM EM EM EM EMEMa,baaaaba,bc,daaaaabbbbbccccccddddEMEMEMEMEMEMfEMEMEMhhhijjjjjjjjjjjjjjjEMEMEMEMEMEMEMEMaaaaacc cbbbbbbbbEMEMEMEMEMa,b,cEMEMEMEMa,bbaaaaEM433EMEMEMLEa,bbaaaaEMEMEMEMEMEMEMEMEMEMEMEMEMEM333EMEM222SECOND FLOOR LOBBY SWITCHING LOCATED AT FIRST FLOOR RECEPTION DESKPP2B/26PP2B/27PP2B/27PP2B/28PP2B/28PP2B/29PP2B/30PP2B/30PP2B/31EP-2A/3221111EP-2A/2EP-2A/2EP-2A/2EP-2A/2EP-2A/3EP-2A/3EP-2A/3EP-2A/3EP-2A/3EP-2A/3EP-2A/3EP-2A/311111111EP-2A/3EP-2A/311EP-2A/3EP-2A/311EP-2A/3EP-2A/3111EP-2A/3EP-2A/3EP-2A/311EP-2A/3EP-2A/3EP-2A/3EP-2A/3EP-2A/3EP-2A/3EP-2A/3EP-2A/3EP-2A/3111111111EP-2A/212EP-2A/2EP-2A/21EP-2A/2EP-2A/2EP-2A/2EP-2A/2EP-2A/211111EP-2A/2EP-2A/2EP-2A/2EP-2A/2EP-2A/2EP-2A/2EP-2A/2EP-2A/2EP-2A/2121111111EP-2A/2EP-2A/22211EP-2A/22111EP-2A/2EP-2A/2EP-2A/2EP-2A/2EP-2A/21EP-2A/22EP-2A/21EP-2A/222111EP-2A/2EP-2A/2EP-2A/2LSLSEMEM22a,bc,d803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:57:42 PME202SECONDFLOORLIGHTING PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1SECOND FLOOR LIGHTING PLANGENERAL NOTES:A. REFER TO DRAWING E201 FOR GENERAL NOTES.DRAWING NOTES:FIXTURE SHALL BE USED AS EMERGENCY. FIXTURE TO BE CIRCUITED AS SHOWN AND SWITCHED, IN TANDEM WITH NORMAL CIRCUIT VIA UL 924 LISTED AUTOMATIC LIGHTING CONTROL RELAY. SEE TANDEM NORMAL/EMERGENCY SWITCHING DETAIL.PROVIDE UL 924 LISTED AUTOMATIC LOAD CONTROL RELAY FOR OPERATION OF EMERGENCY LIGHTING FIXTURES DURING NORMAL POWER FAILURE, REGARDLESS OF CONTROL POSITION. SEE EMERGENCY SWITCHING DETAIL.12REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 DDDDDDDDDDDOSDDOSOSDDDDDDDOSOSDOSOSDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDOSOSDDOSVSVSVSVSDVSVSOSOSOSOSOSOSDDDDDDDDDDDDDDDDDOSDOSOSDOSOSOSDVSVSOSOSOSOSVSOSOSOSOSOSOSDOSDDDDOSOSELEC/DATA323STAIRST2-2NURSEWORKAREA317BSTAIR1ST1-3EXAM/CONSULT321EXAM/CONSULT313EXAM/CONSULT320EXAM/CONSULT314EXAM/CONSULT319EXAM/CONSULT315EXAM/CONSULT318EXAM/CONSULT316PROVIDEROFFICE317FTRIAGENURSE324SPECIALTYEXAM/TREATMENT326PATIENTTOILET327EXAM/CONSULT328EXAM/CONSULT329PROVIDEROFFICE339ANURSEWORK339EXAM/CONSULT327TRIAGENURSE339BPATIENTTOILET336SPECIALTYEXAM/TREATMENT/TELEMED335LAB334PATIENTTOILET335AEXAM/CONSULT328EXAM/CONSULT331SPECIMENCOLLECTION333GUESTWAITING/CIRCULATION300REGISTRATION301PUBLICTOILET300BPUBLICTOILET300ASTAFFTOILET325PATIENTTOILET326AEXAM/CONSULT322CENTRALCLEANWORK312CENTRALSOILEDWORK311EXAM/CONSULT309EXAM/CONSULT308EXAM/CONSULT307EXAM/CONSULT306PROVIDEROFFICE317ASTAFFBREAKAREA305PATIENTTOILET302OFFICEMANAGER301ASTAFFTOILET305ALABDRAW332SPECIALTYEXAM/TREATMENT303PATIENTVITALSALCOVE310EVS330CIRCULATION304CIRCULATION304NURSEWORKAREA317ELALALALALALJLJLALILILILILILILALALILILILILILILILILILILILILILALALALALJLJLALALILILILILILILILILALALALILILILILILILILILILILILILILILILILALILILILILJLJLJLJLJLALALELNLELNLNLNLNLNLNLNLNLNLNLNLNLNLNLNLELELELELNLNLULULULULULULULULULULULULULULULULULULULALNLKLKLKLKLKLKLALJLILILNLNLNLNLNLNLJLNLELJLJLJLULILELELELALALALALALALALALELALULELELJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLHLHLULNLNLELELELJLULULJLILNLZLZLZLZLZLZLZLZLZLZLZLZLZLZLZLZLZX1LNX1X1X1LELEX1X1X1X1X1X1X1X1LNLNLNLNLNLNX1X1X1X1X1X1X1X1X1X1LM3333333333EMEMEMEMX1EMEMEM EM EM EMEMEMEMEMEMEMEMbbccc cbbbbbbbbbbEMLIEMEMEM EM EM EMEMEMbddaaaaaaEM EM EMa,b,c,d,eeeea,ba,ba,babababbbbaaaa,ba,ba,bEMEM3333333333333333333333333333EMEMEMEMEM EMEM EMEM1EMEMEMEM222EP-3ASBP-3APP3BPP3ADP3PP3B/30PP3B/31PP3B/31PP3B/31PP3B/31PP3B/32PP3B/32PP3B/32PP3B/33PP3B/34PP3B/35EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2 EP-3A/2EP-3A/2EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/3EP-3A/3EP-3A/2 EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/2EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3EP-3A/3 EP-3A/3 EP-3A/3EP-3A/3EP-3A/31111111112122211111111221111111122211111121111111211122111111111LSLS22EMEMb,c,eaab,c,eb,c,e803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:57:55 PME203THIRD FLOORLIGHTING PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1THIRD FLOOR LIGHTING PLANGENERAL NOTES:A. REFER TO DRAWING E201 FOR GENERAL NOTES.DRAWING NOTES:FIXTURE SHALL BE USED AS EMERGENCY. FIXTURE TO BE CIRCUITED AS SHOWN AND SWITCHED, IN TANDEM WITH NORMAL CIRCUIT VIA UL 924 LISTED AUTOMATIC LIGHTING CONTROL RELAY. SEE TANDEM NORMAL/EMERGENCY SWITCHING DETAIL.PROVIDE UL 924 LISTED AUTOMATIC LOAD CONTROL RELAY FOR OPERATION OF EMERGENCY LIGHTING FIXTURES DURING NORMAL POWER FAILURE, REGARDLESS OF CONTROL POSITION. SEE EMERGENCY SWITCHING DETAIL.12REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 DDDDDOSOSOSOSOSDDDDDDOSOSDOSDDOSOSDDOSOSDDDOSDOSDDDDDDDDOSOSDOSOSDOSOSDOSOSDDDDDOSVSVSVSVSVSVSVSVSVSVSVSDDDDDDDDOSOSOSOSOSOSOSDDDOSOSOSOSDDDDDOSDDDOSOSOSDDOSOSOSOSOSOSVSDDOSDDDDDLVLVLVLVLVLVLALALALALALALNLNLNLNLNLNLNLNLNLNLNLNLNLCLCLCLCLCLNLNLNLNLRLRLRLRLRLRLNLNLNLNLNLCLCLNLNLNLNLNLNLNLNLNLNLNLNLNLNLCLCLCLNLNLNLNLNLNLILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILILALALILILILILALALILILILILILILILILILILILILILALILILILILILILILILILALALNLALALKLKLKLKLALALALALGLGLALBLBLBLBLKPATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445STAIR1ST1-3EVS439STAIR2ST2-1PROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438PROCEDUREROOM440RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402WOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418ACIRCULATION412HOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS417LNLNLNLELELELALALALALALELELELE33a,bLEaaaabLELELNLELELILILILILILELELALALJLHLHLN33LELELNLNLDLDLNLNaaaabLELELELNLKLILILILILILILNLNLILILILNLHLCLCLCLCLCLCLCLCLLLLLLLLLLLELELJEP-4ASBP-4ADP4PP4BPP4ALELZLZLZLZLZLZLZLZLZLZLNLNLNLNX1X1X1X1X1LILILILILILILIX1X1LNX1X1X1X1X1LNX1LNLNX1X1X1X1X1X1LNX1X1X1X1X1X1LILILIbbX1LILILMEM1EM1EM1EMEMEMEMEMEMEMa,bEMEMEMEMEMEMEMEMEMEMEMEMEMEMEMEMaaaaaccbb bbb bbb33EM EMEMEMEMEMEMEMX1a,b,cEMEM33EMEMEMEMEMEMEMEMEMLNEMEMEMEMEMEM1EMEMEMEMEMEMEM EM EM EMLIEMEMEMEM33EM3333222SBP-4A/6SBP-4A/10SBP-4A/10PP4B/21EMPP4B/21PP4B/21LILILILILIPP4B/22X1X1PP4B/23LIEP-4A/2EP-4A/2EP-4A/4EP-4A/4EP-4A/4EP-4A/4EP-4A/3EP-4A/4FIXTURE ON FLOOR ABOVEEP-4A/4EP-4A/4EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/3 EP-4A/3 EP-4A/3 EP-4A/3 EP-4A/3EP-4A/3EP-4A/3EP-4A/3EP-4A/2 EP-4A/2 EP-4A/2 EP-4A/2 EP-4A/2 EP-4A/2 EP-4A/2EP-4A/2EP-4A/2 EP-4A/2EP-4A/2EP-4A/2EP-4A/2EP-4A/2EP-4A/2EP-4A/2EP-4A/2EP-4A/21122111111111222212221111111111112EP-4A/322111122122111211111111LSLSEMEM22ab,c803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:09 PME204FOURTHFLOORLIGHTING PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FOURTH FLOOR LIGHTING PLANGENERAL NOTES:A. REFER TO DRAWING E201 FOR GENERAL NOTES.DRAWING NOTES:FIXTURE SHALL BE USED AS EMERGENCY. FIXTURE TO BE CIRCUITED AS SHOWN AND SWITCHED, IN TANDEM WITH NORMAL CIRCUIT VIA UL 924 LISTED AUTOMATIC LIGHTING CONTROL RELAY. SEE TANDEM NORMAL/EMERGENCY SWITCHING DETAIL.PROVIDE UL 924 LISTED AUTOMATIC LOAD CONTROL RELAY FOR OPERATION OF EMERGENCY LIGHTING FIXTURES DURING NORMAL POWER FAILURE, REGARDLESS OF CONTROL POSITION. SEE EMERGENCY SWITCHING DETAIL.12REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 DDDDDDDDDDDOSDDOSOSDOSDDDDDDOSOSDOSOSDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDOSOSDDOSVSVSVSVSDVSVSOSOSOSOSOSOSDDDDDDDDDDDDDDDDDOSOSOSOSOSOSOSOSOSOSOSVSOSOSOSOSOSOSDDOSDDDDOSOSOSEXAM/CONSULT521EXAM/CONSULT507EXAM/CONSULT513EXAM/CONSULT522PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529EXAM/CONSULT531CIRCULATION504SPECIALTYEXAM/TREATMENT526PATIENTTOILET527PATIENTTOILET526ASTAFFTOILET525STAFFCIRCULATION517EXAM/CONSULT520EXAM/CONSULT514EXAM/CONSULT519EXAM/CONSULT515EXAM/CONSULT518EXAM/CONSULT516CIRCULATION504BBNURSEWORKAREA517BEXAM/CONSULT509EXAM/CONSULT508SPECIALTYEXAM/TREATMENT506CIRCULATION517DPROVIDEROFFICE517ANURSEWORKAREA517ETRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FREGISTRATION502OFFICEMANAGER502APATIENTTOILET503STAFFBREAKAREA505STAIR3ST3-5STAIRVESTIBULE504ASTAFFTOILET505APUBLICTOILET501APUBLICTOILET501BELEVA500EAELEVB500EBELEVATORCONTROLROOM500LAB534LABDRAW532SPECIMENCOLLECTION533TRIAGENURSE539BPATIENTTOILET536STAIR1ST1-5PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535EXAM/CONSULT537PP5BPP5ADP5EP-5ASBP-5ACENTRALSOILEDWORK511PATIENTVITALSALCOVE510STAIRST2-2STAIR1ST1-3LALALALALALJLJLALILILILILILILILILILILILILILILILILALALILILILILILILILILILILILILILILILILALALALALJLJLALALILILILILILILILILALALALILILILILILILILILILILILILILILILILALILILILILJLJLJLJLJLALALNLNLNLNLNLELNLELNLNLNLNLNLNLNLNLNLNLNLNLNLNLNLELELELELNLNLULULULULULULULULULULULULULULULULULULULULALNLKLKLKLKLKLKLALJLPLILILNLNLNLNLNLNLJLNLELJLJLJLULHATOP OF SHAFTTOP OF SHAFTLILELELELALALALALALALALALELALULELELJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLJLHLHLULNLNLELELELZLZLZLZLZLZLZLZLZLZLZLZLZLZLZLZLZLNLELEX1X1X1LNLNLNLNLNLNX1X1X1X1X1X1X1X1X1X1X1X1X1X1X1X1X1X1X1X13333333333EMEMEMEMEMEMEMEMEMEMEMEMEMEMEMEMEMbbccc cbbbbbbbbbbEMEMEMEMEMEMEMEMEMbddaaaaaaEMEMEMa,b,c,d,eeeea,ba,ba,babababbbbaaaa,ba,ba,bEMEM3333333333333333333333333333EMEMEMEMEM EMEM EMEMEMEMEMEM1EMEMEMEMWPWPEP-1A/5EMEMEMEMEMEMEM2222222222EP-4A/42111EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/4EP-5A/2EP-5A/2EP-5A/2EP-5A/3EP-5A/3EP-5A/3EP-4A/4EP-4A/4EP-4A/4EP-5A/3EP-5A/3EP-5A/3EP-5A/3EP-5A/3EP-5A/3EP-5A/3EP-5A/3EP-5A/3EP-5A/3EP-5A/3EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/4EP-5A/3EP-5A/3EP-5A/3EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/2EP-5A/211111EP-5A/222112EP-5A/211112122111111EP-5A/2111111112111211211111111111112211111SBP-5A/10PP5A/32PP5A/43PP5A/44PP5A/46PP5A/46PP5A/45PP5A/45PP5A/45LSLS22EMEMAEP-1A/5a,da,db,c,eb,c,eb,c,eXLALSLSEMEM22EM3803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:26 PME205FIFTH FLOORLIGHTING PLAN02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIFTH FLOOR LIGHTING PLAN3/16" = 1'-0"2ROOF LIGHTING PLANGENERAL NOTES:A. REFER TO DRAWING E201 FOR GENERAL NOTES.DRAWING NOTES:FIXTURE SHALL BE USED AS EMERGENCY. FIXTURE TO BE CIRCUITED AS SHOWN AND SWITCHED, IN TANDEM WITH NORMAL CIRCUIT VIA UL 924 LISTED AUTOMATIC LIGHTING CONTROL RELAY. SEE TANDEM NORMAL/EMERGENCY SWITCHING DETAIL.PROVIDE UL 924 LISTED AUTOMATIC LOAD CONTROL RELAY FOR OPERATION OF EMERGENCY LIGHTING FIXTURES DURING NORMAL POWER FAILURE, REGARDLESS OF CONTROL POSITION. SEE EMERGENCY SWITCHING DETAIL.FIXTURE SHALL BE USED FOR EMERGENCY EGRESS. CIRCUIT VIA AUTOMATIC LOAD CONTROL RELAY TO ALLOW FOR BYPASS OF ALL SWITCHING DURING LOSS OF NORMAL POWER. NORMAL SENSING CIRCUIT SHALL TIE INTO EXTERIOR LIGHTING BRANCH CIRCUIT SHOWN AHEAD OF SWITCHING. DEVICE SHALL BE MOUNTED ABOVE CEILING. REFER TO DETAIL SHEETS FOR MORE INFORMATION..123REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 UTILITY 3000A/3PLSIG3000A, 208Y/120V, 3 PH, 4W, 65KAIC400A/3PMDP600A/3P200A/3PATS1000A, 208Y/120V, 3 PH, 4W, 65KAICGDP600A/3P200A/3PATS1000A/3P1000A/3PGFIGG-1250KW/313KVADIESEL GENERATOR208Y/120V3 PH, 4WWEATHERPROOFSOUND ATTENUATED ENCLOSURE32 HOUR SUB BASE TANK200A, 208Y/120V, 3 PH, 4W, 65KAICEMDP100A/3P200A/3PATS-EM200A3 PH, 4W OPEN TRANSITIONATS-SB600A3 PH, 4W OPEN TRANSITIONEP-1A100A/3PMCB100A/3PEP-2A100A/3PMCB100A/3PEP-3A100A/3PMCB100A/3PEP-4A100A/3PMCB100A/3PEP-5A100A/3PMCB600A, 208Y/120V, 3 PH, 4W, 65KAIC600A/3P225A/3PSBP-1A225A/3PMCBSBDP225A/3PSBP-2A225A/3PMCB225A/3PSBP-3A225A/3PMCB225A/3PSBP-4A225A/3PMCB225A/3PSBP-5A225A/3PMCB400A, 208Y/120V, 3 PH, 4W, 42KAIC225A/3PPP-1BDP1225A/3PPP-1A400A/3P400A, 208Y/120V, 3 PH, 4W, 42KAIC225A/3PPP-2B225A/3PPP-2ADP2400A/3P400A, 208Y/120V, 3 PH, 4W, 42KAIC225A/3PPP-3BDP3225A/3PPP-3A400A/3P400A, 208Y/120V, 3 PH, 4W, 42KAIC225A/3PPP-4B225A/3PPP-4ADP4400A/3P400A, 208Y/120V, 3 PH, 4W, 42KAIC225A/3PPP-5BDP5225A/3PPP-5A500A/3PT-X1150KVA208V PRI480Y/277V SEC3 PH, 4W300AS100AFDISCONNECT480Y/2773 PH,4W100A/3P ECBX-RAY500A/3PT-X2150KVA208V PRI480Y/277V SEC3 PH, 4W300AS100AFDISCONNECT480Y/2773 PH,4W100A/3P ECBX-RAYABBBCCCCCCDFFFGHEAAA60A/3PTVSSFEEDER SCHEDULEWIRE SIZE IN AWGNO.PHASENEUTRALGROUNDCONDUITABCDEOVERCURRENT PROTECTIONF3-#21-#21-#81-1/2"100A/3PGH3-#3/01-#3/01-#62"200A/3P3-#4/0 1-#4/0 1-#4 2-1/2"225A/3P3-500 KCM1-500 KCM1-#23-1/2"400A/3P6-350 KCM2-350 KCM2-#1(2)3"600A/3P9-500 KCM3-500 KCM3-#2/0(3)3-1/2"1000A/3P24-500 KCM 8-500 KCM8-400 KCM3000A/3P(8)3-1/2"6-250 KCM 2-250 KCM 2-#2500A/3P(2)2-1/2"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:29 PME301ONE-LINEDIAGRAM02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1ONE-LINE DIAGRAMREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 PROVIDE INTERLOCK KIT IN DISCONNECT SWITCH. PROVIDE 2-#2,1/2"C FROM ELEVATOR CONTROLLER TO THE DISCONNECT SWITCH FOR BATTERY LOWERING. SINGLE POINT CONNECTION TO DUPLEX PUMPING SYSTEM.CONNECT TO NEAREST RECEPTACLE CIRCUIT.PROVIDE 2-#18, 1/2"C BETWEEN THE EVAPORATOR (INDOOR) SECTION, AND THE RESPECTIVE AIRCOOLED CONDENSER (OUTDOOR) SECTION.EC TO PROVIDE SUPPLY SIDE DUCT SMOKE DETECTOR, MC TO INSTALL.CIRCUIT TO ASSOCIATED INDOOR UNIT CIRCUIT. REFER TO VENDOR WIRING DIAGRAMS AND COORDINATE WITH MECHANICAL CONTRACTOR FOR FINAL REQUIREMENTS.MOTOR RATED SWITCHMANUAL MOTOR STARTERMANUAL MOTOR STARTER WITH RELAY MAGNETIC STARTERCOMBINATION MAGNETIC STARTERVARIABLE FREQUENCY DRIVECOMBINATION TWO SPEED MAGNETIC STARTERCOMBINATION REDUCE VOLTAGE MAGNETIC STARTERDUPLEX CONTROLLER WITH ALTERNATOR CIRCUITPACKAGED CONTROL UNITH-O-A SELECTOR SWITCH IN COVERPILOT LIGHT IN COVERREMOTE START-STOP PUSHBUTTONSFIRE ALARM FAN SHUTDOWNLINE-VOLTAGE THERMOSTAT1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.NOTES:MOTOR STARTER NOTES:A.B.C.D.E.F.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:35 PME401SCHEDULES02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGELECTRICAL EQUIPMENT AND CONTROL SCHEDULEEQUIPMENTSUPPLY DISCONNECT SWITCH CONTROLSNOTESNAME LOCATION HP KW MCA PHASE VOLTAGE SOURCECIRCUITBREAKERWIRING FROM SOURCE TOCONTROL UNITWIRING FROM CONTROL UNITTO EQUIPMENTSWITCHAMPSFUSESIZENEMARATINGCONTROLLERLOCATIONMOTOR STARTER/CONTROL NOTENEMASIZENEMARATINGDFC-05D MULTIPLE 0.80 A 1 208 PP1B/31,33 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05F MULTIPLE 0.80 A 1 208 PP1B/31,33 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05G MULTIPLE 0.80 A 1 208 PP1B/30,32 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05H MULTIPLE 0.80 A 1 208 PP1B/30,32 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05I MULTIPLE 0.80 A 1 208 PP1B/26,28 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05J MULTIPLE 0.80 A 1 208 PP2B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05K MULTIPLE 0.80 A 1 208 PP2B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05L MULTIPLE 0.80 A 1 208 PP2B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05M MULTIPLE 0.80 A 1 208 PP2B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05N MULTIPLE 0.80 A 1 208 PP2B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05O MULTIPLE 0.80 A 1 208 SBP-4A/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05P MULTIPLE 0.80 A 1 208 SBP-4A/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05Q MULTIPLE 0.80 A 1 208 PP4B/28,30 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05R MULTIPLE 0.80 A 1 208 PP4B/28,30 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05S MULTIPLE 0.80 A 1 208 PP4B/28,30 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05T MULTIPLE 0.80 A 1 208 PP4B/28,30 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05U MULTIPLE 0.80 A 1 208 PP4B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05X MULTIPLE 0.80 A 1 208 PP4B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1 AU 10 - - -DFC-05Y MULTIPLE 0.80 A 1 208 PP5B/42,44 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05Z MULTIPLE0.80 A 1 208 PP5B/42,44 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07A MULTIPLE0.80 A 1 208 PP1B/26,28 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07B MULTIPLE0.80 A 1 208 PP1B/26,28 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07D MULTIPLE0.80 A 1 208 SBP-1A/70,72 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07E MULTIPLE0.80 A 1 208 SBP-4A/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07F MULTIPLE0.80 A 1 208 PP4B/29,31 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07G MULTIPLE0.80 A 1 208 PP5B/50,52 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07H MULTIPLE0.80 A 1 208 PP4B/25,27 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07I MULTIPLE0.80 A 1 208 PP4B/32,34 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07J MULTIPLE0.80 A 1 208 PP5B/42,44 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07L MULTIPLE0.80 A 1 208 PP3B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07M MULTIPLE0.80 A 1 208 PP3B/45,47 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07N MULTIPLE0.80 A 1 208 PP4B/32,34 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07O MULTIPLE0.80 A 1 208 PP2B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07P MULTIPLE0.80 A 1 208 PP4B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-07Q MULTIPLE0.80 A 1 208 PP4B/32,34 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09B MULTIPLE0.80 A 1 208 PP1B/27,29 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09E MULTIPLE0.80 A 1 208 PP2B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09F MULTIPLE0.80 A 1 208 PP2B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09G MULTIPLE0.80 A 1 208 PP2B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09H MULTIPLE0.80 A 1 208 PP2B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09I MULTIPLE0.80 A 1 208 SBP-4A/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09J MULTIPLE0.80 A 1 208 PP4B/25,27 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09K MULTIPLE0.80 A 1 208 PP5B/51,53 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09L MULTIPLE0.80 A 1 208 PP5B/47,49 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09M MULTIPLE0.80 A 1 208 PP5B/51,53 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09N MULTIPLE0.80 A 1 208 PP5B/54,56 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09O MULTIPLE0.80 A 1 208 PP3B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09P MULTIPLE0.80 A 1 208 PP3B/45,47 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09Q MULTIPLE0.80 A 1 208 PP3B/48,50 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09R MULTIPLE0.80 A 1 208 SBP-1A/66,68 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-09S MULTIPLE0.80 A 1 208 PP1B/31,33 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12A MULTIPLE0.80 A 1 208 SBP-1A/66,68 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12B MULTIPLE0.80 A 1 208 SBP-1A/70,72 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12D MULTIPLE0.80 A 1 208 PP2B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12E MULTIPLE0.80 A 1 208 PP2B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12F MULTIPLE0.80 A 1 208 PP4B/24,26 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12G MULTIPLE0.80 A 1 208 PP4B/24,26 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12H MULTIPLE0.80 A 1 208 PP4B/29,31 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12I MULTIPLE0.80 A 1 208 PP4B/29,31 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12J MULTIPLE0.80 A 1 208 PP4B/32,34 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12K MULTIPLE0.80 A 1 208 PP4B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12L MULTIPLE0.80 A 1 208 PP4B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12N MULTIPLE0.80 A 1 208 PP5B/43,45 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12O MULTIPLE0.80 A 1 208 PP5B/47,49 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12P MULTIPLE0.80 A 1 208 PP3B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12Q MULTIPLE0.80 A 1 208 PP3B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12R MULTIPLE0.80 A 1 208 SBP-1A/67,69 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-12S MULTIPLE0.80 A 1 208 PP4B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15A MULTIPLE1.40 A 1 208 PP1B/26,28 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15B MULTIPLE1.40 A 1 208 PP1B/27,29 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15D MULTIPLE1.40 A 1 208 SBP-1A/70,72 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15E MULTIPLE1.40 A 1 208 SBP-1A/70,72 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15G MULTIPLE1.40 A 1 208 PP2B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15H MULTIPLE1.40 A 1 208 PP2B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15I MULTIPLE1.40 A 1 208 SBP-4A/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15J MULTIPLE1.40 A 1 208 SBP-4A/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15K MULTIPLE1.40 A 1 208 PP4B/24,26 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15L MULTIPLE1.40 A 1 208 PP4B/29,31 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15M MULTIPLE1.40 A 1 208 PP2B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15N MULTIPLE1.40 A 1 208 PP2B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15O MULTIPLE1.40 A 1 208 PP3B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-15P MULTIPLE1.40 A 1 208 PP5B/50,52 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18A MULTIPLE1.60 A 1 208 PP1B/31,33 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18B MULTIPLE1.60 A 1 208 PP2B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18C MULTIPLE1.60 A 1 208 PP2B/40,42 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18E MULTIPLE1.60 A 1 208 PP4B/24,26 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18F MULTIPLE1.60 A 1 208 PP5B/42,44 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18G MULTIPLE1.60 A 1 208 PP5B/46,48 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18H MULTIPLE1.60 A 1 208 PP5B/46,48 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18I MULTIPLE1.60 A 1 208 PP3B/45,47 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18J MULTIPLE1.60 A 1 208 PP3B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18K MULTIPLE1.60 A 1 208 PP3B/40,42 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18L MULTIPLE1.60 A 1 208 PP3B/40,42 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-18M MULTIPLE1.60 A 1 208 PP5B/50,52 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-24A MULTIPLE1.80 A 1 208 SBP-1A/66,68 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-24B MULTIPLE1.80 A 1 208 SBP-1A/66,68 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-24C MULTIPLE1.80 A 1 208 PP2B/40,42 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-24D MULTIPLE1.80 A 1 208 PP2B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-24F MULTIPLE1.80 A 1 208 PP2B/32,34 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-30A MULTIPLE1.80 A 1 208 SBP-1A/66,68 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-30B MULTIPLE1.80 A 1 208 SBP-4A/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-30C MULTIPLE1.80 A 1 208 PP2B/40,42 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-36A MULTIPLE2.50 A 1 208 PP2B/32,34 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-36B MULTIPLE2.50 A 1 208 PP5B/46,48 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-36C MULTIPLE2.50 A 1 208 PP3B/40,42 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DOAS-1ROOF4103.80 A 3 208 MDP/20,22,24 110A/3P 3-#2 & 1-#8EG IN 1 1/2"C 3-#2 & 1-#8EG IN 1 1/2"C - - -AU10,14- - EDOAS-2ROOF8229.10 A 3 208 SBDP/27,29,31 250A/3P 3-250KCM & 1-#4EG IN 2 1/2"C 3-250KCM & 1-#4EG IN 2 1/2"C - - -AU10,14- - EDOAS-3ROOF8229.10 A 3 208 SBDP/28,30,32 250A/3P 3-250KCM & 1-#4EG IN 2 1/2"C 3-250KCM & 1-#4EG IN 2 1/2"C - - -AU10,14- - EEF-1560ROOF 0.751 120 PP5B/63 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 3R -ELEV-A3 208 SBDP/20,22,24 100A/3P S.T 3-#2 & 1-#8EG IN 1 1/2"C 3-#2 & 1-#8EG IN 1 1/2"C 100A 100A 3R AU10- - AELEV-B3 208 SBDP/19,21,23 100A/3P S.T. 3-#2 & 1-#8EG IN 1 1/2"C 3-#2 & 1-#8EG IN 1 1/2"C 100A 100A 3R AU10- - AESP-1A0.51 120 SBP-1A/83 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 3R -ESP-1B0.51 120 SBP-1A/83 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 3R -HWH-1A MECH. ROOM4.51 208 SBP-1A/78,80 30A/2P 3-#10 & 1-#10EG IN 1/2"C 3-#10 & 1-#10EG IN 1/2"C 30A NF 3R AU10- - -HWH-1B MECH. ROOM4.51 208 PP2A/38,40 30A/2P 3-#10 & 1-#10EG IN 1/2"C3-#10 & 1-#10EG IN 1/2"C 30A NF 3R AU10- - -HWH-1C MECH. ROOM4.51 208 PP3A/44,46 30A/2P 3-#10 & 1-#10EG IN 1/2"C3-#10 & 1-#10EG IN 1/2"C 30A NF 3R AU10- - -HWH-1D MECH. ROOM4.51 208 PP4A/30,32 30A/2P 3-#10 & 1-#10EG IN 1/2"C3-#10 & 1-#10EG IN 1/2"C 30A NF 3R AU10- - -HWH-1E MECH. ROOM4.51 208 PP5A/48,50 30A/2P 3-#10 & 1-#10EG IN 1/2"C3-#10 & 1-#10EG IN 1/2"C 30A NF 3R AU10- - -HWRP-1A0.171 120 SBP-1A/82 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 3R CHWRP-1B0.171 120 PP2A/42 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 3R CHWRP-1C0.171 120 PP3A/47 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 3R CHWRP-1D0.171 120 PP4A/34 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 3R CHWRP-1E0.171 120 PP5A/52 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 3R CELECTRICAL EQUIPMENT AND CONTROL SCHEDULEEQUIPMENTSUPPLY DISCONNECT SWITCH CONTROLSNOTESNAME LOCATION HP KW MCA PHASE VOLTAGE SOURCECIRCUITBREAKERWIRING FROM SOURCE TOCONTROL UNITWIRING FROM CONTROL UNITTO EQUIPMENTSWITCHAMPSFUSESIZENEMARATINGCONTROLLERLOCATIONMOTOR STARTER/CONTROL NOTENEMASIZENEMARATINGAC-1 VESTIBULE 100V1 20 58.40 A 3 208 PP1A/35,37,39 80A/3P 3-#2 & 1-#8EG IN 1 1/2"C 3-#2 & 1-#8EG IN 1 1/2"C 100A NF 3R AU10- - -AC-2 VESTIBULE 100V220 58.40 A 3 208 PP1A/36,38,40 80A/3P 3-#2 & 1-#8EG IN 1 1/2"C 3-#2 & 1-#8EG IN 1 1/2"C 100A NF 3R AU10- - -AC-18A MULTIPLE0.50 A 1 208 PP1B/35,37 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-18B MULTIPLE0.50 A 1 208 SBP-1A/75,77 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-18C MULTIPLE0.50 A 1 208 SBP-1A/75,77 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-18D MULTIPLE0.50 A 1 208 SBP-2A/11,13 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-18E MULTIPLE0.50 A 1 208 SBP-3A/12,14 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-18F MULTIPLE0.50 A 1 208 SBP-4A/42,44 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-18G MULTIPLE0.50 A 1 208 SBP-4A/42,44 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-18H MULTIPLE0.50 A 1 208 SBP-5A/11,13 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-18I MULTIPLE0.50 A 1 208 SBP-5A/12,14 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-24A MULTIPLE0.24 A 1 208 PP5B/55,57 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-24B MULTIPLE0.24 A 1 208 PP5B/58,60 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DAC-24C MULTIPLE0.24 A 1 208 PP3B/49,51 15A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 DACCU-1EROOF38.10 A 3 208 SBP-5A/19,21,23 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-1NROOF38.10 A 3 208 SBP-5A/20,22,24 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-1SROOF38.10 A 3 208 DP1/8,10,12 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-1WROOF38.10 A 3 208 DP1/7,9,11 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-2EROOF38.10 A 3 208 DP2/13,15,17 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-2NROOF38.10 A 3 208 DP2/8,10,12 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-2SROOF38.10 A 3 208 DP2/14,16,18 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-2WROOF38.10 A 3 208 DP2/7,9,11 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-3EROOF38.10 A 3 208 DP3/13,15,17 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-3NROOF38.10 A 3 208 DP3/8,10,12 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-3SROOF38.10 A 3 208 DP3/14,16,18 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-3WROOF38.10 A 3 208 DP3/7,9,11 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-4EROOF38.10 A 3 208 DP4/8,10,12 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-4NROOF38.10 A 3 208 DP4/7,9,11 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-4SROOF38.10 A 3 208 DP4/13,15,17 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-4WROOF38.10 A 3 208 SBP-4A/36,38,40 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-5EROOF38.10 A 3 208 DP5/13,15,17 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-5NROOF38.10 A 3 208 DP5/8,10,12 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-5SROOF38.10 A 3 208 DP5/14,16,18 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -ACCU-5WROOF38.10 A 3 208 DP5/7,9,11 45A/3P 3-#8 & 1-#10EG IN 3/4"C 3-#8 & 1-#10EG IN 3/4"C 60A NF 3R AU10- - -BF-1AMULTIPLE 0.11 208 SBP-1A/79,81 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 1 CBF-1BMULTIPLE 0.11 208 PP2A/39,41 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 1 CBF-1CMULTIPLE 0.11 208 PP3A/43,45 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 1 CBF-1DMULTIPLE 0.11 208 PP4A/31,33 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 1 CBF-1EMULTIPLE 0.11 208 PP5A/49,51 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU1,11,120 1 CBS-10.40 A 1 208 PP1B/26,28 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-20.40 A 1 208 PP1B/27,29 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-30.40 A 1 208 PP1B/27,29 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-40.40 A 1 208 SBP-1A/66,68 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-50.40 A 1 208 SBP-1A/67,69 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-60.40 A 1 208 SBP-1A/67,69 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-70.40 A 1 208 SBP-1A/67,69 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-80.40 A 1 208 SBP-1A/67,69 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-90.40 A 1 208 SBP-1A/70,72 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-100.40 A 1 208 SBP-1A/70,72 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-110.40 A 1 208 SBP-1A/70,72 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-120.40 A 1 208 SBP-1A/70,72 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-130.40 A 1 208 PP1B/30,32 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-140.40 A 1 208 PP1B/31,33 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-150.40 A 1 208 PP2B/32,34 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-160.40 A 1 208 PP2B/32,34 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-170.40 A 1 208 PP2B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-180.40 A 1 208 PP2B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-190.40 A 1 208 PP2B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-200.40 A 1 208 PP2B/40,42 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-210.40 A 1 208 PP2B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-220.40 A 1 208 PP2B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-230.40 A 1 208 PP3B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-240.40 A 1 208 PP3B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-250.40 A 1 208 PP3B/40,42 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-260.40 A 1 208 PP3B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-270.40 A 1 208 PP3B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-280.40 A 1 208 PP3B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-290.40 A 1 208 PP3B/45,47 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-300.40 A 1 208 PP3B/48,50 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-310.40 A 1 208 SBP-4A/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-320.40 A 1 208 SBP-4A/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-330.40 A 1 208 PP4B/24,26 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-340.40 A 1 208 PP4B/24,26 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-350.40 A 1 208 PP4B/25,27 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-360.40 A 1 208 PP4B/25,27 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-370.40 A 1 208 PP4B/28,30 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-380.40 A 1 208 PP4B/29,31 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-390.40 A 1 208 PP4B/32,34 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-400.40 A 1 208 PP4B/33,35 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-410.40 A 1 208 PP4B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-420.40 A 1 208 PP4B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-430.40 A 1 208 PP5B/42,44 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-440.40 A 1 208 PP5B/43,45 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-450.40 A 1 208 PP5B/46,48 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-460.40 A 1 208 PP5B/46,48 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-470.40 A 1 208 PP5B/47,49 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-480.40 A 1 208 PP5B/50,52 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-490.40 A 1 208 PP5B/51,53 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FBS-500.40 A 1 208 PP5B/54,56 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU3,11,120 1 FCU-18AROOF16.50 A 1 208 PP1B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-18BROOF16.50 A 1 208 SBP-1A/71,73 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-18CROOF16.50 A 1 208 SBP-1A/74,76 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-18DROOF16.50 A 1 208 SBP-2A/12,14 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-18EROOF16.50 A 1 208 SBP-3A/13,15 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-18FROOF16.50 A 1 208 SBP-4A/45,47 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-18GROOF16.50 A 1 208 SBP-4A/46,48 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-18HROOF16.50 A 1 208 SBP-5A/15,17 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-18IROOF16.50 A 1 208 SBP-5A/16,18 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-24AROOF16.20 A 1 208 PP5B/59,61 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCU-48AROOF33.20 A 1 208 PP5B/62,64 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 3R AU10- - DCUH-1A1.51 120 PP1B/34 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU10- - -CUH-1B1.51 120 PP3B/52 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU10- - -CUH-1C1.51 120 PP2B/45 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU10- - -CUH-1D1.51 120 PP3B/53 20A/1P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C - - -AU10- - -DBP-153.75 A 3 208 MDP/25,27,29 60A/3P 3-#6 & 1-#10EG IN 1"C3-#6 & 1-#10EG IN 1"C- - - CONTROLLER 10- - BDFC-05A MULTIPLE0.80 A 1 208 SBP-1A/67,69 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AA MULTIPLE0.80 A 1 208 PP5B/42,44 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AB MULTIPLE0.80 A 1 208 PP5B/43,45 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AC MULTIPLE0.80 A 1 208 PP5B/43,45 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AD MULTIPLE0.80 A 1 208 PP5B/50,52 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AE MULTIPLE0.80 A 1 208 PP5B/46,48 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AF MULTIPLE0.80 A 1 208 PP5B/47,49 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AG MULTIPLE0.80 A 1 208 PP5B/47,49 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AH MULTIPLE0.80 A 1 208 PP5B/47,49 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AI MULTIPLE0.80 A 1 208 PP5B/47,49 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AJ MULTIPLE0.80 A 1 208 PP5B/47,49 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AK MULTIPLE0.80 A 1 208 PP5B/54,56 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AL MULTIPLE0.80 A 1 208 PP5B/54,56 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AM MULTIPLE0.80 A 1 208 PP5B/54,56 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AN MULTIPLE0.80 A 1 208 PP5B/51,53 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AO MULTIPLE0.80 A 1 208 SBP-4A/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AP MULTIPLE0.80 A 1 208 PP5B/42,44 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AQ MULTIPLE0.80 A 1 208 PP5B/47,49 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AR MULTIPLE0.80 A 1 208 PP3B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AS MULTIPLE0.80 A 1 208 PP3B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AT MULTIPLE0.80 A 1 208 PP3B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AU MULTIPLE0.80 A 1 208 PP3B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AV MULTIPLE0.80 A 1 208 PP3B/36,38 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AW MULTIPLE0.80 A 1 208 PP3B/37,39 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AX MULTIPLE0.80 A 1 208 PP3B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AY MULTIPLE0.80 A 1 208 PP3B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05AZ MULTIPLE0.80 A 1 208 PP3B/41,43 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05B MULTIPLE0.80 A 1 208 SBP-1A/67,69 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BA MULTIPLE0.80 A 1 208 PP3B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BB MULTIPLE0.80 A 1 208 PP3B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BC MULTIPLE0.80 A 1 208 PP3B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BD MULTIPLE0.80 A 1 208 PP3B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BE MULTIPLE0.80 A 1 208 PP3B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BF MULTIPLE0.80 A 1 208 PP3B/44,46 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BG MULTIPLE0.80 A 1 208 PP3B/48,50 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BH MULTIPLE0.80 A 1 208 PP3B/48,50 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BI MULTIPLE0.80 A 1 208 PP3B/48,50 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05BJ MULTIPLE0.80 A 1 208 PP3B/45,47 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -DFC-05C MULTIPLE0.80 A 1 208 SBP-1A/67,69 20A/2P 2-#12 & 1-#12EG IN 1/2"C 2-#12 & 1-#12EG IN 1/2"C 30A NF 1AU10- - -REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 Zone SummaryZoneSpace TypeArea (ft²)Ithaca ECSupplement(W/ft^2)EC4B Wattage EC4B LPDWaterService_146_flr1CS Electrical/Mechanical , 173 0.48 50.30 0.29Mech_145_flr1CS Electrical/Mechanical , 254 0.48 75.45 0.30Exam_112_113_114_115_116_120_121_flr1SS Healthcare, Exam/Treatment 847 0.83 341.46 0.40Exam_118_flr1SS Healthcare, Exam/Treatment 1410.8366.660.47Sub-waiting_105B_flr1CS Lounge/Break, Healthcare 1490.46105.000.70Toilet_105C_flr1CS Restroom 670.6142.000.63Offic_104_flr1CS Office, Enclosed 1100.5666.660.61Toilet_103_flr1CS Restroom 640.6142.000.66StaffBreak_102_flr1CS Lounge/Break, Healthcare 1350.4666.660.49Reception_101B_flr1CS Office, Enclosed 1200.5642.000.35Vesti_100v2_flr1CS Corridor, Other 690.3356.000.81Lobby_100_101_flr1CS Corridor, Other 2,0960.331127.390.54Register_124_flr1CS Office, Enclosed 1410.56187.281.33Lab_126_flr1SS Healthcare, Radiology/Imaging 1320.7682.970.63Toilet_131_flr1CS Restroom 410.6133.330.81Specimen Toilet_127_flr1CS Restroom 490.6133.330.68BreakRm_133_flr1CS Lounge/Break, Healthcare 860.4633.330.39CleanSupply_134_flr1CS Storage Room 570.3249.180.86WasteHolding_136_flr1CS Storage Room 1610.3298.360.61CleanLinenHold_137_flr1CS Storage Room 1940.32147.540.76Stairs_ST_flr1CS Stairwell 3740.3560.000.16Elec_142_flr1CS Electrical/Mechanical , 630.4825.150.40EquipRoom_141_flr1CS Storage Room 840.3250.300.60Toilet_138A_flr1CS Restroom 640.6149.180.77Server_140_flr1CS Electrical/Mechanical , 1050.4850.300.48SupplyChainArea_138_flr1CS Office, Enclosed 6140.56491.800.80EVSSupplynEquiRoom_139_flrCS Storage Room 1580.3298.360.62Treatment_117_flr1SS Healthcare, Exam/Treatment 1440.8366.660.46Clean hold_107_flr1CS Storage Room 580.3233.330.57Radiology_119_flr1SS Healthcare, Radiology/Imaging 2510.76100.000.40SoiledHold_111_132_flr1CS Storage Room 720.3249.640.69EVS_109_flr1CS Storage Room 540.3233.330.62Circulation 105_105ACS Corridor_Other 1,3310.33670.410.50NurseCore_108_flr1SS Healthcare, Nurses’ Station 1400.36137.860.99StatLab_110_flr1SS Healthcare, Radiology/Imaging 910.7666.660.73Triage_106_flr1SS Healthcare, Exam/Treatment 1300.8366.660.51Waiting_Circ_123_flr1CS Corridor, Other 5270.33203.820.39Toilet_100A_B_101A_flr1CS Restroom 1620.6184.000.52Elev_100EA_flr1 1960.00EVS_125_Storage 144_flr1CS Storage Room 1430.3225.150.18Corr_135_1_flr1CS Corridor, Other 2360.33133.320.56BloodDraw_128-130_flr1SS Healthcare, Radiology/Imaging 3200.76146.340.46Corri_122_flr1CS Corridor, Other 5800.33266.540.46Corri_143_flr1CS Corridor, Other 5320.33233.310.44Holding_100C_flr1CS Storage Room 760.3233.330.44Vest_100V1_flr1CS Corridor, Other 880.3384.000.95Nurse_214_flr2SS Healthcare, Nurses’ Station 2070.36145.000.70Exam_215-217_flr2SS Healthcare, Exam/Treatment 3630.83147.000.40Offi_213_flr2CS Office, Enclosed 960.5640.000.42Exam_210-212_flr2SS Healthcare, Exam/Treatment 3570.83147.000.41ManagerOffice_209_flr2CS Office, Enclosed 840.5640.000.48BreakRm_208_flr2CS Lounge/Break, Healthcare 1010.4660.000.59MultiPur_204_flr2CS Conference/Meeting/Multipurpose, 800.62113.001.41Office_203_flr2CS Office, Enclosed 1180.5680.000.68Walking Track_flr2CS Corridor, Other 1,8650.33940.000.50Stair1_flr2CS Stairwell 3370.3540.000.12BreakRm_242_flr2CS Lounge/Break, Healthcare 4380.46200.000.46Lactation_239-241_flr2CS Lounge/Break, Healthcare 1830.46115.200.63Circulation_228_flr2CS Corridor_Other 2280.33240.001.05Office_238_flr2CS Office, Enclosed 840.5640.000.48Stair2_ST2_flr2CS Stairwell 2180.3540.000.18Elec_243_flr2CS Electrical/Mechanical , 750.4850.000.67EVS_flr2CS Storage Room 190.3216.000.84Exam_218_flr2SS Healthcare, Exam/Treatment 1190.8398.000.82SoiledHold_229_flr2CS Storage Room 540.3240.000.74DentalOffice_230_flr2CS Office, Enclosed 800.5640.000.50EquiStorage_231_flr2CS Storage Room 540.3240.000.74Waiting_flr2CS Lounge/Break, Healthcare 7130.46316.310.44MedPrep_219_flr2CS Office, Enclosed 1210.5680.000.66DentalEqui_227_flr2CS Storage Room 1030.3280.000.78EVS_226_flr2CS Storage Room 190.3216.310.88Exam_220_flr2SS Healthcare, Exam/Treatment 1690.8398.000.58DentalTreat_225_flr2SS Healthcare, Exam/Treatment 1600.8398.000.61Lab_221_flr2SS Healthcare, Radiology/Imaging 1000.7680.000.80Toilet_222_224_flr2CS Restroom 1680.61109.420.65MultiPurpose_206_flr2CS Conference/Meeting/Multipurpose, 800.62113.241.42MultiPurpose_204_flr2CS Conference/Meeting/Multipurpose, 800.62113.241.42Toilet_205_flr2CS Restroom 460.6133.600.73Reception\Registration_202CS Office, Enclosed 2480.56204.000.82Toilet_200AB_flr2CS Restroom 1030.6167.200.65Corridor_232_flr2CS Corridor, Other 5740.33396.310.69Elev_200EAEB_flr2 1940.00Telemed_233_flr2CS Office, Enclosed 1110.56110.841.00Multipurpose_235_234_flr2CS Conference/Meeting/Multipurpose, 6980.62400.000.57Stor_235A_flr2CS Storage Room 420.3216.000.38Toilet_236_237_flr2CS Restroom 1540.61107.200.70Circulation_207_flr2CS Corridor, Other 6390.33480.000.75ELEC/DATA_323_flr3CS Electrical/Mechanical , 760.4850.000.66Stair2_ST2-3_flr3CS Stairwell 2570.3540.000.16Elev_flr3 2080.00Stair1_flr3CS Stairwell 3360.3540.000.12Toilet_300AB_302_305A_326A_327_325_335A_336_flr3CS Restroom 4410.61321.600.73Exam_327-329_331_flr3SS Healthcare, Exam/Treatment 6030.83196.000.33Exam_319-322_flr3SS Healthcare, Exam/Treatment 5980.83196.000.33Exam 306-309_313-316_flr3SS Healthcare, Exam/Treatment 9580.83392.000.41Break_305_flr3CS Lounge/Break, Healthcare 2470.46120.000.49Exam 303_flr3SS Healthcare, Exam/Treatment 1820.8398.000.54Circulation_300_flr3CS Corridor_Other 1,4970.33711.000.47Reception\Registration_301_flr3CS Office, Enclosed 7030.56464.000.66Office_301A_flr3CS Office, Enclosed 980.5680.000.82Soiled_Clean Work_311-312_flr3CS Office, Enclosed 3110.56160.000.51Circulation_317_flr3CS Corridor_Other 6620.33480.000.73Office_317A_317F_flr3CS Office, Enclosed 3040.56160.000.53Nurse_317BE_324_flr3SS Healthcare, Nurses’ Station 7140.36264.000.37Nurse_339_339B_flr3SS Healthcare, Nurses’ Station 4950.36340.000.69Exam 326_335_flr3SS Healthcare, Exam/Treatment 3040.8398.000.32Office_339A_flr3CS Office, Enclosed 2070.5680.000.39Lab_332-334_flr3SS Healthcare, Radiology/Imaging 2380.76124.400.52Circulation_304_flr3CS Corridor_Other 1,2210.33816.000.67Office_428_flr4CS Office, Enclosed 910.5680.000.88Waiting_407_flr4CS Lounge/Break, Healthcare 5270.46372.800.71Circulation_425_flr4CS Corridor, Other 8050.33600.000.75Circulation_406_flr4CS Corridor, Other 2170.33157.200.72Gowning_407A-D_flr4CS Restroom 1770.61132.800.75Registration/MNGR_402_403_CS Office, Enclosed 3320.56376.001.13Waiting_401_flr4CS Lounge/Break, Healthcare 7230.46412.000.57Stair_1_flr4CS Stairwell 3680.3560.000.16Offfice_436A_flr4CS Office, Enclosed 1070.5680.000.75Reception_436_flr4CS Office, Enclosed 1610.5680.000.50ProcRm_440_441_flr4SS Healthcare, Exam/Treatment 3270.83272.000.83ProcRm_442_flr4SS Healthcare, Exam/Treatment 1620.83136.000.84Break_443_flr4CS Lounge/Break, Healthcare 1160.4680.000.69Stair_2_flr4CS Stairwell 2640.3560.000.23ELEC/DATA_430_flr4CS Electrical/Mechanical , 680.4850.000.74Imaging_429_flr4SS Healthcare, Radiology/Imaging 360.7626.000.72Mammography_427_flr4SS Healthcare, Radiology/Imaging 1640.7696.000.59Reading_426_flr4CS Office, Enclosed 1080.5640.000.37Ultrasound_423_424_flr4SS Healthcare, Radiology/Imaging 3610.76163.000.45Circulation_422_flr4CS Corridor, Other 4830.33346.000.72Ultasound_415_flr4SS Healthcare, Radiology/Imaging 1730.7664.000.37Toilet_413_414_415A_418B_flr4CS Restroom 2060.61139.200.68Holding_412AB3_flSS Healthcare, Exam/Treatment 1460.8376.800.53Storage_400C_404_421_flr4CS Storage Room 1910.32121.000.63Diag/Radio_416_flr4SS Healthcare, Radiology/Imaging 2730.76120.000.44NurseTech_411_flr4SS Healthcare, Nurses’ Station 2300.36128.000.56Gowning_418A_flr4CS Restroom 470.6144.000.94Mammography_431_flr4SS Healthcare, Radiology/Imaging 2080.76144.000.69Circulation_412_flr4CS Corridor, Other 2680.33104.000.39Multipurpose_405_flr4CS Conference/Meeting/Multipurpose, 1250.62121.600.97Toilet_400AB_flr4CS Restroom 1030.6167.200.65DEXASCAN_432_flr4SS Healthcare, Radiology/Imaging 1750.7640.000.23EquiStor_431a_flr4CS Storage Room 380.3226.000.68SoilHold_420_flr4CS Storage Room 1090.3280.000.73CleanHold_419_flr4CS Storage Room 1090.3280.000.73EVS_417_flr4CS Storage Room 300.3216.000.53Waiting_418_flr4CS Lounge/Break, Healthcare 1750.46144.000.82Gowning_424A_flr4CS Restroom 450.6128.800.64Toilet_423A_flr4CS Restroom 660.6143.200.65Toilet_444_445_flr4CS Restroom 1000.6176.800.77SoilHold_438_flr4CS Storage Room 1120.3280.000.71CleanHold_437_flr4CS Storage Room 1340.3280.000.60EVS_439_flr4CS Storage Room 190.3216.000.84Conference_433_flr4CS Conference/Meeting/Multipurpose, 2050.62125.200.61Elev_flr4 1960.00Lobby/Corr_400_flr4CS Lobby, Other 1,0170.90532.000.52Waiting/Circ_434_435_flr4CS Lounge/Break, Healthcare 4500.46256.000.57Results_410_flr4SS Healthcare, Nurses’ Station 2100.36100.000.48Office_517F_flr5CS Office, Enclosed 1430.5680.000.56NurseWork_517E_flr5SS Healthcare, Nurses’ Station 2020.36132.000.65Circulation_517_flr5CS Corridor, Other 5790.33364.000.63StairVestibule_504A_flr5CS Corridor, Other 570.3316.000.28BreakArea_505_flr5CS Lounge/Break, Healthcare 2810.46160.000.57Toilet_505A_flr5CS Restroom 560.6141.600.74Registration_502_flr5CS Office, Enclosed 7030.56664.000.94Waiting/Circ_501_flr5CS Lounge/Break, Healthcare 1,4390.46691.000.48Stair1_S501_flr5CS Stairwell 3680.35120.000.33Toilet_536_flr5CS Restroom 550.6148.000.87Triage_539B_flr5SS Healthcare, Exam/Treatment 390.8340.001.03NurseWork_539_flr5SS Healthcare, Nurses’ Station 4280.36234.000.55Office_539A_flr5CS Office, Enclosed 1810.5680.000.44Exam_526_flr5SS Healthcare, Exam/Treatment 1520.8398.000.64Stair2_S502_flr5CS Stairwell 2700.35120.000.44IT/ELEC_523_flr5CS Electrical/Mechanical , 940.4850.000.53Triage_524_flr5SS Healthcare, Exam/Treatment 1140.8380.000.70Circulation_517CD_flr5CS Corridor, Other 3260.3378.000.24Exam_518to522_flr5SS Healthcare, Exam/Treatment 5980.83245.000.41Toilet_525_flr5CS Restroom 490.6134.800.71Exam_537_538_flr5SS Healthcare, Exam/Treatment 2400.8398.000.41Toilet_526A_527_flr5CS Restroom 890.6169.740.78Exam_513_514_515_516_flr5SS Healthcare, Exam/Treatment 4790.83196.000.41Office_517A_flr5CS Office, Enclosed 1580.5680.000.51NurseWork517b_flr5SS Healthcare, Nurses’ Station 2020.36120.000.59Exam_506to509_flr5SS Healthcare, Exam/Treatment 5240.83245.000.47Circulation_504_flr5CS Corridor, Other 9480.33560.000.59Toilet_503_flr5CS Restroom 570.6136.800.65Office_502A_flr5CS Office, Enclosed 980.5680.000.82Toilet_501AB_flr5CS Restroom 1030.6172.000.70Circulation_504BB_flr5CS Corridor, Other 2450.33208.000.85CentralCleanStor_512_flr5CS Storage Room 1200.3280.000.67CentralHold_511_flr5CS Storage Room 1240.3280.000.65Vitals_510_flr5SS Healthcare, Nurses’ Station 690.3696.001.39Elev_flr5 2080.00ElevControl_500_flr5CS Electrical/Mechanical , 530.4825.000.47Lab_532_533_534_flr5SS Healthcare, Radiology/Imaging 2230.76124.400.56Toiler_5335a_flr5CS Restroom 460.6137.900.82Exam_535_flr5SS Healthcare, Exam/Treatment 1500.8398.000.65Storeage 535B_539C_flr5CS Storage Room 230.320.00Exam_528_529_531_flr5SS Healthcare, Exam/Treatment 3580.83147.000.41EVS_530_flr5CS Storage Room 210.3216.000.76 53,449 0.50 29,148.06 0.55Total 1st floor 11,679 6,006 0.51total 2nd floor 9,682 5,591 0.58total 3rd floor 10,660 5,231 0.49total 4th floor 10,757 6,474 0.60total 5th floor 10,672 5,846 0.55Total Footprint63,24129,148 0.461. ELECTRICAL CONTRACTOR TO SUBMIT MODEL SHOWN OR APPROVED EQUAL2. PROVIDE APPROPRIATE FLANGE KIT FOR GRID OR HARD CEILING AS REQUIRED. VERIFY CEILING TYPE PRIOR TO PURCHASE3. ALL FIXTURES TO BE PROVIDED WITH DIMMABLE DRIVERS DOWN TO 1%.4. ALL INTERIOR FIXTURES SHALL BE 3500K.5. ALL EXTERIOR FIXTURES SHALL BE 4000K.6. ALL FIXTURES SHALL BE 90 CRI OR GREATER.7. PLEASE NOTE: EC4B submittal review process for lighting and fixture substitutions:Equivalency of substitute fixtures during the bid process shall be the sole responsibility of the Electrical Contractor and their Lighting Representatives.After bid, Electrical Contractor shall provide basis of design fixture for project unless the following conditions are met:a. Substitute package shall provide all required information necessary to prove equivalency in TABLE FORMAT for expedient review of equivalency submittals.b. Upon commencement of review, if more than two fixtures are found to be Non-Compliant, the entire package will be rejected.c. All resubmissions will be handled on an hourly basis for review, with retainer provided prior to commencement of resubmission.d. Non-Compliant fixtures will again dictate a rejection of the entire package.Electrical Contractor has a responsibility to the involved parties (Owner/GC/Architect/Engineer) to ensure that provided substitute packages are compliant equivalent to the specified fixtures. Lack of attention to detail and thoroughness will create delays which will be the sole responsibility of said contractor.LUMINAIRE SCHEDULE NOTES:803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:40 PME402SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGLUMINAIRE SCHEDULETYPEDESCRIPTIONLAMPEFFICACY(LPW)MOUNTING VOLTAGEMODELNOTESA 1'X4' VAPORTIGHT, LINEAR LED, POLYCARBONATEHOUSING, FROSTED LENS, 4000 LUMENS, 3500K40W LED 100 Surface 120METALUX VAPORTITELEDEM1 EMERGENCY LED WALL PACK, 2 FIXED HEADS,WHITE THERMOPLASTIC HOUSING, 90 MINUTEBATTERY BACKUP(2) 1.2W LEDSurface 120 LITHONIA CATALOGELM2LFl13" LED LINEAR, RECESSED , PERIMTER FILLDIFFUSER, 470 LUMENS PER FOOT, 3500K, 0-10VDIMMING, BLACK, DAMP LOCATION4W/FT 118 Recessed 120 PRUDENTIAL LIGHTINGBIONICOPRO3PROVIDE LIT CORNERS AS REQUIREDTO PROVIDE CONTINUOS LENGTH OFLIGHT. VERIFY FINAL ROW LENGTHSPRIOR TO ORDERING.LA2'x4', LED TROFFER, HIGH EFFICIENCY ACRYLICLENS, EDGE-LIT, EXTRUDED ALUMINUM, 5648LUMENS, 3500K, 0-10V DIMMING37W LED 147 Recessed 120 COLUMBIA LIGHTINGVERSIFY VSY24LB2" APERTURE PENDANT, ACRYLIC DIFFUSER,CLOSED BOTTOM, 3000K, STEM MOUNTED4W LED 110 Surface 120 EUREKA LIGHTING4156BLC 2" LED RECESSED DOWNLIGHT, 40 DEGREE DIFFUSELENS, 875 LUMENS, 3500K, 0-10V DIMMING10W LED 87.5 Recessed 120 ALPHABET LIGHTINGECONU2RDLD 2'x4', LED FLAT PANEL, EDGE LIT, ACRYLIC LENS,5000 LUMENS, 3500K, 0-10V DIMMING40W LED 125 Recessed 120 COLUMBIA LIGHTINGCFP24LE 4" LED LINEAR, RECESSED, ASYMETRIC DIFFUSER,600 LUMENS PER FOOT, 3500K, 0-10V DIMMING4.8W/FT LED 117120 LITECONTROL 4-L-RDLF4" LED LINEAR, RECESSED, ASYMETRICDIFFUSER,700 LUMENS PER FOOT, 3500K, 0-10VDIMMING6.1W/FT LED 116 Recessed 120 LITECONTROL 4-L-RDLG 18" ROUND, LED, STEEL AND ALUMINUM RING, OPALPOLYCARBONATE DIFFUSER, 3532 LUMENS, 3500K,0-10V DIMMING30W LED 118 Surface 120 BETA CALCO TIMPANIRDLH 4' LINEAR LED STRIP, ACRYLIC DIFFUSE FLAT LENS,3000 LUMENS, 3500K, STEEL CONSTRUCTION25W LED 120 Surface 120 LITHONIA ZL1NLI 4' T-BAR LED LIGHT, ACRYLIC DIFFUSE LENS, 2600LUMENS, 3500K, 0-10V DIMMING20W LED 130120 TGS LIGHTING T-SPECLJ2'x4', LED TROFFER, HIGH EFFICIENCY ACRYLICLENS, EDGE-LIT, EXTRUDED ALUMINUM, 3754LUMENS, 3500K, 0-10V DIMMING26W LED 144 Recessed 120 COLUMBIA LIGHTINGVERSIFY VSY22LK 24" ROUND, LED, STEEL AND ALUMINUM RING, OPALPOLYCARBONATE DIFFUSER, 5329 LUMENS, 3500K,0-10V DIMMING44W LED 121 Surface 120 BETA CALCO TIMPANIRDLL 4" LED LINEAR, RECESSED, BATWING DIFFUSER, 600LUMENS PER FOOT, 3500K, 0-10V DIMMING4.8W/FT LED 117 Recessed 120 LITECONTROL 4-L-RDLM 4" LED LINEAR, RECESSED, ASYMETRIC DIFFUSER,600 LUMENS PER FOOT, 3500K, 0-10V DIMMING4.8W/FT LED 117120 LITECONTROL 4-L-RDLN 4" LED RECESSED DOWNLIGHT, 70 DEGREE HIGHEFFICIENCY DIFFUSE LENS, 1600 LUMENS, 3500K,0-10V DIMMING16W LED 100 Recessed 120 ALPHABET LIGHTINGECONU4RDLP CIRCULAR DIRECT LED RING CHANDELIER, 24", 48",AND 72" RINGS WITH OPAL ACRYLIC LENS, 13000LUMENS, 3500K, 0-10V DIMMING156W LED 83 Suspended 120 DELRAY LIGHTING UCGYROSCOPECOORDINATE MOUNTING HEIGHT WITHARCHITECTLQ3" LED LINEAR, RECESSED , PERIMTER FILLDIFFUSER, 470 LUMENS PER FOOT, 3500K, 0-10VDIMMING, BLACK, DAMP LOCATION4W/FT118 Recessed 120 PRUDENTIAL LIGHTINGBIONICOPRO3PROVIDE LIT CORNERS AS REQUIREDTO PROVIDE CONTINUOUS LENGTH OFLIGHT. FIXTURE IS AN 'L' (7'4"x9') AND (2)10'4.5" AND 10'6.5" ROWS. VERIFY FINALROW LENGTHS PRIOR TO ORDERING.LR 6" LED RECESSED DOWNLIGHT, 70 DEGREE HIGHEFFICIENCY DIFFUSE LENS, 2500 LUMENS, 3500K,0-10V DIMMING26W LED 96 Recessed 120 ALPHABET LIGHTINGECONU6RDLS 4' LINEAR LED, WIDE DIFFUSE LENS, 4000 LUMENS,3500K, 0-10V DIMMING, WALL MOUNT, INTEGRALOCCUPANCY SENSOR WITH AUTO DIMMING, DIM TO50% WHEN UNOCCUPIED28W LED 142 Surface 120 LITHONIA LIGHTING CLX PROVIDE ONE FIXTURE PER LANDINGLT 2" LED RECESSED DOWNLIGHT, 40 DEGREE DIFFUSELENS, 875 LUMENS, 3500K, 0-10V DIMMING, WETLOCATION10W LED 87.5 Recessed 120 ALPHABET LIGHTINGECONU2RDLU2'x4', LED TROFFER, HIGH EFFICIENCY ACRYLICLENS, EDGE-LIT, EXTRUDED ALUMINUM, 7185LUMENS, 3500K, 0-10V DIMMING49W LED 147 Recessed 120 COLUMBIA LIGHTINGVERSIFY VSY24LV 2'x4', LED MED ROOM LIGHT, ANTI MICROBIAL FINISH,DIFFUSE LENS, ALUMINUM HOUSING, GASKETTINGON ACCESS DOOR AND DOOR FRAME, 8000 LUMENS,3500K, 0-10V DIMMING68W LED 118 Recessed 120 KURTZON ML-FPGASERIESLW UV-A LED STRIP LIGHT, 365 NANOMETER TO 395NANOMETER WAVELENGTH, W/ ALUMINUM CORNERCHANNEL WITH DIFFUSED ACRYLIC LENS4.8W/FT LEDSurface 120 WAVEFORM LIGHTINGREALUV LED STRIPLIGHTPROVIDE ALL REQUIRE MOUNTINGACCESSORIES AND POWER SUPPLIESLXLED STRIP LED, 206LM/FT, RGBW,FLEXIBLE 3.82W/FT LED 54 Surface 120 MODALIGHT STAR FLEXRGBWLYLED STRIP LED, FLEXIBLE, 3500K,383LM/FT,DIMMABLE, LOW VOLTAGE, EDGE LIT STRIP4.4W/FT LED 87 Surface 120 MODALIGHT EDGEINTERIOR 3500KPROVIDE ALL REQUIRE MOUNTINGACCESSORIES AND POWER SUPPLIESLZ LED UNDERCABINET LIGHT, ACRYLIC DIFFUSE LENS,485 LUMENS PER FOOT, 3500K, WHITE, DIMMABLE8W/FT LED 60 Surface120 BRUCK LIGHTINGWUNDERCABPROVIDE LENGTHS AS REQUIRED FORCONTINUOUS LIGHTING BELOWCABINETS SHOWN.X1UNIVERAL MOUNTED, EDGE LIT EXIT LUMINAIREWITH GREEN LETTERING W/ 90 MIN NICAD BATTERYAND SELF-TESTING/SELF-DIAGNOSTICLEDRecessed 120 DUAL LITE LE SERIES PROVIDE CHEVRONS AS REQUIREDXLA EXTERIOR WALL LIGHT, IMPACT RESISTANT, 6879LUMENS, 4000K, IP6554W LED 127 Wall 120 LIGMAN LIGHTINGUVK30042XLB43" TALL, EXTERIOR SCONCE, WET LOCATION,WHITE ACRYLIC DIFFUSER, ALUMINUM FINISH, 3000LUMENS, 4000K29W LED 100 Wall 120 SHAPER LIGHTING674-WPXLC3" LED LINEAR, RECESSED , PERIMTER FILLDIFFUSER, 685 LUMENS PER FOOT, 3500K, 0-10VDIMMING, BLACK, IC RATED, DAMP LOCATION6W/FT 112 Recessed 120 PRUDENTIAL LIGHTINGBIONICOPRO3PROVIDE LIT CORNERS AS REQUIREDTO PROVIDE CONTINUOUS LENGTH OFLIGHT. FIXTURE IS AN 'L' (9'1"x40'4").VERIFY FINAL ROW LENGTHS PRIOR TOORDERING.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:42 PME403SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNOTES:Heating40.35100.00%40.35Power332.2651.50%171.13Other24.46100.00%24.46TOTAL EST. DEMAND...2294.80 AMotor40.65100.00%40.65TOTAL CONN....2742.04 ALighting28.35100.00%28.35TOTAL EST. DEMAND:826.74HVAC521.81100.00%521.81TOTAL CONN. LOAD:987.87LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:2854.35 A 2722.37 A 2669.58 ATOTAL LOAD:341.68 325.84 320.35MDP/41SPACE-- --00 -- --SPACEMDP/42MDP/39SPACE-- --00-- --SPACEMDP/40MDP/37SPACE-- -- 00-- --SPACEMDP/38MDP/350 0 -- -- SPACE MDP/36MDP/330 0 -- -- SPACE MDP/34MDP/31T-X1 500 A 30 0 -- -- SPACE MDP/32MDP/295.63 0 MDP/30MDP/275.630MDP/28MDP/25DBP-1 60 A 35.63 03500 A T-X2MDP/26MDP/231.5 9.93 MDP/24MDP/214 9.93 MDP/22MDP/19ATS-EM 200 A 36.63 9.933110 A DOAS-1MDP/20MDP/1746.35 117.85 MDP/18MDP/1545.92112.37MDP/16MDP/13DP5 400 A 347.91 119.013 600 A ATS-SBMDP/14MDP/1140.11 28.48 MDP/12MDP/944.1725.82MDP/10MDP/7DP3 400 A 340.52 31.073400 A DP4MDP/8MDP/532.6 37.91 MDP/6MDP/341.4536.55MDP/4MDP/1DP1 400 A 342.99 37.983400 A DP2MDP/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTMDPMECHANICAL-3145-33000.00 A/MCB 3 4 120/208 Wye Floor QED 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMFEED THRU LUGSISOLAT. GND BUSSE RATEDXCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Heating0.07100.00%0.07Power96.3255.19%53.16Other6.46100.00%6.46TOTAL EST. DEMAND...883.24 AMotor40.13100.00%40.13TOTAL CONN....1003.04 ALighting11.17100.00%11.17TOTAL EST. DEMAND:318.2HVAC207.22100.00%207.22TOTAL CONN. LOAD:361.36LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:1050.82 A 969.77 A 998.38 ATOTAL LOAD:125.64 116.37 119.35GDP/11SPACE-- --00 -- --SPACEGDP/12GDP/9SPACE-- --00-- --SPACEGDP/10GDP/7SPACE-- -- 00-- --SPACEGDP/8GDP/5117.85 1.5 GDP/6GDP/3112.374GDP/4GDP/1ATS-SB 600 A 3119.01 6.633 200 A ATS-EMGDP/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTGDPEMERGENCYEQUIPMENT...1000.00 A/MCB 3 4 120/208 Wye Surface 42K I-LINE NEMA-1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Heating0.07100.00%0.07Power91.9255.44%50.96Other6.46100.00%6.46TOTAL EST. DEMAND...855.67 AMotor40.13100.00%40.13TOTAL CONN....969.37 ALighting3.44100.00%3.44TOTAL EST. DEMAND:308.27HVAC207.22100.00%207.22TOTAL CONN. LOAD:349.23LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:998.77 A 936.44 A 989.09 ATOTAL LOAD:119.01 112.37 117.85SBDP/41SPACE-- --00 -- --SPACESBDP/42SBDP/39SPACE-- --00-- --SPACESBDP/40SBDP/37SPACE-- -- 00-- --SPACESBDP/38SBDP/35SPACE-- --00 -- --SPACESBDP/36SBDP/33SPACE-- --00-- --SPACESBDP/34SBDP/3121.9821.98SBDP/32SBDP/2921.98 21.98 SBDP/30SBDP/27DOAS-2 250 A 321.98 21.983250 A DOAS-3SBDP/28SBDP/25SHUNT TRIP-- -- 00-- --SHUNT TRIPSBDP/26SBDP/236.67 6.67 SBDP/24SBDP/216.676.67SBDP/22SBDP/19ELEV-B 100 A 36.67 6.673 100 A ELEV-ASBDP/20SBDP/1715.72 0 -- -- SPACE SBDP/18SBDP/1513.190-- --SPACESBDP/16SBDP/13SBP-5A 225 A 312.83 0 -- -- SPACE SBDP/14SBDP/112.09 17.86 SBDP/12SBDP/95.0817.14SBDP/10SBDP/7SBP-3A 225 A 35.07 16.173 225 A SBP-4ASBDP/8SBDP/521.85 3.03 SBDP/6SBDP/316.33.36SBDP/4SBDP/1SBP-1A 225 A 322.34 5.313 225 A SBP-2ASBDP/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTSBDPEMERGENCYEQUIPMENT...ATS-SB 600.00 A/MCB 3 4 120/208 Wye Surface 42K I-LINE NEMA-1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...33.67 APower4.4100.00%4.4TOTAL CONN....33.67 AOther00.00%0TOTAL EST. DEMAND:12.13Lighting7.73100.00%7.73TOTAL CONN. LOAD:12.13LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:58.46 A 36.54 A 12.50 ATOTAL LOAD:6.63 4 1.5EMDP/41SPACE-- --00 -- --SPACEEMDP/42EMDP/39SPACE-- --00-- --SPACEEMDP/40EMDP/37SPACE-- -- 00-- --SPACEEMDP/38EMDP/35SPACE-- --00 -- --SPACEEMDP/36EMDP/33SPACE-- --00-- --SPACEEMDP/34EMDP/31SPACE-- -- 00-- --SPACEEMDP/32EMDP/29SPACE-- --00 -- --SPACEEMDP/30EMDP/27SPACE-- --00-- --SPACEEMDP/28EMDP/25SPACE-- -- 00-- --SPACEEMDP/26EMDP/23SPACE-- --00 -- --SPACEEMDP/24EMDP/21SPACE-- --00-- --SPACEEMDP/22EMDP/19SPACE-- -- 00-- --SPACEEMDP/20EMDP/170.36 0 -- -- SPACE EMDP/18EMDP/150.920-- --SPACEEMDP/16EMDP/13EP-5A 100 A 30.98 0 -- -- SPACE EMDP/14EMDP/1100 EMDP/12EMDP/90.920.92EMDP/10EMDP/7EP-3A 100 A 30.98 0.93 100 A EP-4AEMDP/8EMDP/51.14 0 EMDP/6EMDP/30.760.48EMDP/4EMDP/1EP-1A 100 A 31.43 2.343 100 A EP-2AEMDP/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTEMDPEMERGENCYEQUIPMENT...ATS-EM 200.00 A/MCB 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:45 PME404SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNOTES:Heating40100.00%40Power38.962.85%24.45Other00.00%0TOTAL EST. DEMAND...284.76 AMotor0.33100.00%0.33TOTAL CONN....324.87 ALighting2.72100.00%2.72TOTAL EST. DEMAND:102.59HVAC35.09100.00%35.09TOTAL CONN. LOAD:117.04LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:369.64 A 356.73 A 271.64 ATOTAL LOAD:42.99 41.45 32.6DP1/41SPACE-- --00 -- --SPACEDP1/42DP1/39SPACE-- --00-- --SPACEDP1/40DP1/37SPACE-- -- 00-- --SPACEDP1/38DP1/35SPACE-- --00 -- --SPACEDP1/36DP1/33SPACE-- --00-- --SPACEDP1/34DP1/31SPACE-- -- 00-- --SPACEDP1/32DP1/29SPACE-- --00 -- --SPACEDP1/30DP1/27SPACE-- --00-- --SPACEDP1/28DP1/25SPACE-- -- 00-- --SPACEDP1/26DP1/23SPACE-- --00 -- --SPACEDP1/24DP1/21SPACE-- --00-- --SPACEDP1/22DP1/19SPACE-- -- 00-- --SPACEDP1/20DP1/17SPACE-- --00 -- --SPACEDP1/18DP1/15SPACE-- --00-- --SPACEDP1/16DP1/13SPACE-- -- 00-- --SPACEDP1/14DP1/114.6 4.6 DP1/12DP1/94.6 4.6DP1/10DP1/7ACCU-1W 20 A 34.6 4.63 45 A ACCU-1SDP1/8DP1/517.11 6.29 DP1/6DP1/320.7211.53DP1/4DP1/1PP1A 225 A 321.08 12.723 225 A PP1BDP1/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTDP1MAINELECTRICAL-1...MDP 400.00 A/MCB 3 4 120/208 Wye Surface 42K I-LINE Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...151.17 ATOTAL CONN....163.55 AHeating40100.00%40TOTAL EST. DEMAND:54.46Power18.9276.43%14.46TOTAL CONN. LOAD:58.92LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:180.32 A 177.32 A 142.61 ATOTAL LOAD:21.08 20.72 17.11PP1A/41SPACE-- --00 -- --SPACEPP1A/42PP1A/396.676.67PP1A/40PP1A/376.676.67PP1A/38PP1A/35AC-1 80 A 36.67 6.673 80 A AC-2PP1A/36PP1A/330.951.4PP1A/34PP1A/31SITE LIGHTING 20 A 20.95 1.42 20 A SITE LIGHTINGPP1A/32PP1A/29E EXTERIOR RCPT20 A 10.180.18 1 20 AN EXTERIOR RCPTPP1A/30PP1A/27S EXTERIOR RCPT20 A 10.180.361 20 AW EXTERIOR RCPTPP1A/28PP1A/25Power Space 60620 A 1 0.18PP1A/26PP1A/23 CORRIDOR 135 RCPT 20 A 10.360.18 1 20 A ELEVATOR WATER COOLERPP1A/24PP1A/21 STAFF BREAK WATER COOLER 20 A 10.180.541 20 ACORR 122 RCPTPP1A/22PP1A/19 CLEAN HOLDING RCPT 20 A 1 0.360.181 20 A PATIENT TOILET RCPT PP1A/20PP1A/17 SUB-WAITING WATER COOLER 20 A 10.180.54 1 20 AWAITING 105 RCPTPP1A/18PP1A/15 ELECTRICAL RM RCPT 20 A 10.540.721 20 A WATER AND UTILITY RM RCPT PP1A/16PP1A/13 SUPPLY CHAIN AREA RC[T 20 A 1 1.620.361 20 ACORR 143 RCPTPP1A/14PP1A/11MAIL/TOILET RCPT20 A 10.540.72 1 20 AEVS SUPPLY RCPTPP1A/12PP1A/9LOBBY CORR RCPT20 A 11.080.721 20 A WAITING/CIRCULATION RCPTPP1A/10PP1A/7 WATING/CIRCULATION CORR... 20 A 1 0.361.081 20 ALOBBY RCPTPP1A/8PP1A/5 REGISTRATION RCPT 20 A 10.180.72 1 20 A REGISTRATION WORKSTATION... PP1A/6PP1A/3TOILET RCPT20 A 10.360.361 20 A Power LABORATORY-1 125-1 PP1A/4PP1A/1SUPPLY RCPT 120 A 1 0.540.721 20 A STAFF BREAK 133 RCPT PP1A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP1AMAINELECTRICAL-1...DP1 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Power19.9875.03%14.99Other00.00%0TOTAL EST. DEMAND...70.92 AMotor0.33100.00%0.33TOTAL CONN....84.77 ALighting2.72100.00%2.72TOTAL EST. DEMAND:25.55HVAC7.51100.00%7.51TOTAL CONN. LOAD:30.54LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:112.70 A 102.80 A 52.42 ATOTAL LOAD:12.72 11.53 6.29PP1B/53SPACE-- --00 -- --SPACEPP1B/54PP1B/51SPACE-- --00-- --SPACEPP1B/52PP1B/49SPACE-- -- 00-- --SPACEPP1B/50PP1B/47SPACE-- --00 -- --SPACEPP1B/48PP1B/45SPARE20 A 1001 20 ASPAREPP1B/46PP1B/43SPARE20 A 1 001 20 ASPAREPP1B/44PP1B/41SPARE20 A 100 1 20 ASPAREPP1B/42PP1B/39SPARE20 A 1001 20 ASPAREPP1B/40PP1B/370.051.72PP1B/38PP1B/35AC-18A 15 A 20.05 1.722 20 A CU-18APP1B/36PP1B/330.461.51 20 ACUH-1APP1B/34PP1B/31BS-14 & DFC-05D,F & DFC-09S &DFC-18A20 A 20.46 0.21PP1B/32PP1B/290.31 0.212 20 A BS-13 & DFC-05G,HPP1B/30PP1B/27BS-2,3 & DFC-09B & DFC-15B 20 A 20.310.44PP1B/28PP1B/25 BLOOD DRAW 128 RCPT 20 A 1 0.720.44220 ABS-1 & DFC-05I & DFC-07A,B &DFC-15APP1B/26PP1B/23 BLOOD DRAW 130 RCPT 20 A 10.720.72 1 20 A BLOOD DRAW 129 RCPTPP1B/24PP1B/213.63.6PP1B/22PP1B/19EV CAR CHARGER 40 A 23.6 3.62 40 A EV CAR CHARGERPP1B/20PP1B/17EXT RCPT20 A 10.180.9 1 20 A2ND FLR RCPTPP1B/18PP1B/15 STAFF BREAK 133... 20 A 10.1801 20 ASPAREPP1B/16PP1B/13BREAK 102 RCPT20 A 1 0.360.181 20 ABREAK 102 RCPTPP1B/14PP1B/11SPARE20 A 100.18 1 20 ABREAK 102 MICROPP1B/12PP1B/9MAIN LOBBY LTS20 A 10.7301 20 ASPAREPP1B/10PP1B/7 RM 123, 130, 129, 128, 126, 132,... 20 A 1 0.860.181 20 A REG 124 COPIER RCPT PP1B/8PP1B/5 RM 144, 145, 146, 139, 138,... 20 A 1 1.13 0.18 1 20 A WATER COOLER RCPT PP1B/6PP1B/3LAB 126 RCPT20 A 10.180.541 20 AMAIL 100C RCPTPP1B/4PP1B/1LAB 126 RCPT20 A 1 0.180.181 20 ALAB 126 RCPTPP1B/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP1BMAINELECTRICAL-1...DP1 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Heating0.07100.00%0.07Power41.0462.18%25.52Other6.46100.00%6.46TOTAL EST. DEMAND...124.80 AMotor0.5100.00%0.5TOTAL CONN....167.88 ALighting1.97100.00%1.97TOTAL EST. DEMAND:44.96HVAC10.44100.00%10.44TOTAL CONN. LOAD:60.48LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:193.24 A 135.84 A 189.16 ATOTAL LOAD:22.34 16.3 21.85SBP-1A/83ESP-1A,B20 A 11.960 1 20 ASPARESBP-1A/84SBP-1A/810.040.131 20 AHWRP-1ASBP-1A/82SBP-1A/79BF-1A 20 A 20.04 2.25SBP-1A/80SBP-1A/770.1 2.252 30 A HWH-1ASBP-1A/78SBP-1A/75AC-18B,C 15 A 20.1 1.72 SBP-1A/76SBP-1A/731.721.722 20 ACU-18CSBP-1A/74SBP-1A/71CU-18B 20 A 21.72 0.62 SBP-1A/72SBP-1A/690.490.622 20 ABS-9,10,11,12 & DFC-07D &DFC-12B & DFC-15D,ESBP-1A/70SBP-1A/67BS-5,6,7,8 & DFC-05A,B,C &DFC-12R20 A 20.49 0.77SBP-1A/68SBP-1A/65SPARE20 A 100.772 20 ABS-4 & DFC-09R & DFC-12A &DFC-24A,B & DFC-30ASBP-1A/66SBP-1A/63SPARE20 A 1001 20 ASPARESBP-1A/64SBP-1A/61SPARE20 A 1 001 20 ASPARESBP-1A/62SBP-1A/59QUICK CARE LTS20 A 10.520 1 20 ASPARESBP-1A/60SBP-1A/57EXAM RM LTS20 A 10.790.661 20 A QUICK CARE CORR, CIRC LTSSBP-1A/58SBP-1A/55 CHECKIN KIOSK RCPT 20 A 10.54 0.36 1 20 A RM 109, 101A RCPT SBP-1A/56SBP-1A/53STAT LAB RCPT20 A 10.180.18 1 20 ASTAT LAB RCPTSBP-1A/54SBP-1A/51STAT LAB RCPT20 A 10.360.181 20 ASTAT LAB RCPTSBP-1A/52SBP-1A/49 RECEPTION 101 RCPT 20 A 1 0.90.91 20 A VITALS WORKSTATION RCPT SBP-1A/50SBP-1A/47LOBBY 101 RCPT20 A 11.260.18 1 20 A LOBBY WATER COOLER SBP-1A/48SBP-1A/45 STAFF BREAK 102 RCPT 20 A 10.360.181 20 A STAFF BREAK 102... SBP-1A/46SBP-1A/43SCALE20 A 1 0.181.081 20 A SHARED PROVIDER OFFICE... SBP-1A/44SBP-1A/41 NURSE CORE WORKSTATION... 20 A 10.720.72 1 20 A NURSE CORE WORKSTATION... SBP-1A/42SBP-1A/39 DOOR OPERATORS20 A 10.360.361 20 ADOOR OPERATORS SBP-1A/40SBP-1A/37 DOOR OPERATOR20 A 1 0.180.181 20 ADOOR OPERATOR SBP-1A/38SBP-1A/351.5 1.5 SBP-1A/36SBP-1A/33MAIN SERV L6-30R 30 A 21.5 1.52 30 A MAIN SERV L6-30RSBP-1A/34SBP-1A/311.51.5SBP-1A/32SBP-1A/29MAIN SERV L6-30R 30 A 21.5 1.52 30 A MAIN SERV L6-30RSBP-1A/30SBP-1A/271.51.5SBP-1A/28SBP-1A/25MAIN SERV L6-30R 30 A 21.5 1.52 30 A MAIN SERV L6-30RSBP-1A/26SBP-1A/23ELEV PIT RCPT20 A 10.180.18 1 20 ALAB 110 UC REFSBP-1A/24SBP-1A/21LAB 126 UC REF20 A 10.180.181 20 A ELEVATOR PIT RCPT SBP-1A/22SBP-1A/19 RADIOLOGY RCPT20 A 1 0.90.181 20 ALAB 126 UC REFSBP-1A/20SBP-1A/17EXAM 121 RCPT20 A 10.90.9 1 20 AEXAM 120 RCPTSBP-1A/18SBP-1A/15 DOOR OPERATOR20 A 10.180.721 20 A TRIAGE/INTERVIEW RCPT SBP-1A/16SBP-1A/13EXAM 118 RCPT20 A 1 0.90.91 20 AEXAM 112 RCPTSBP-1A/14SBP-1A/11EXAM 114 RCPT20 A 10.90.9 1 20 AEXAM 113 RCPTSBP-1A/12SBP-1A/9EXAM 116 RCPT20 A 10.90.91 20 AEXAM 115 RCPTSBP-1A/10SBP-1A/7 SERVER ROOM RCPT 20 A 1 0.360.9 1 20 A TREATMENT 117 RCPT SBP-1A/8SBP-1A/5 SERVER ROOM RCPT 20 A 10.360.36 1 20 A SERVER ROOM RCPT SBP-1A/6SBP-1A/3 SOILED WORK RCPT 20 A 10.360.541 20 A CIRCULATION CORR 105 RCPT SBP-1A/4SBP-1A/1DOOR OPERATOR20 A 1 0.360.541 20 ACORR 105 RCPTSBP-1A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTSBP-1AMAINELECTRICAL-1...SBDP 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...9.24 APower1.04100.00%1.04TOTAL CONN....9.24 AOther00.00%0TOTAL EST. DEMAND:3.33Lighting2.29100.00%2.29TOTAL CONN. LOAD:3.33LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:12.40 A 6.34 A 9.99 ATOTAL LOAD:1.43 0.76 1.14EP-1A/29SPARE20 A 100 1 20 ASPAREEP-1A/30EP-1A/27SPARE20 A 1001 20 ASPAREEP-1A/28EP-1A/25SPARE20 A 1 001 20 ASPAREEP-1A/26EP-1A/23SPARE20 A 100 1 20 ASPAREEP-1A/24EP-1A/21SPARE20 A 1001 20 ASPAREEP-1A/22EP-1A/19SPARE20 A 1 001 20 ASPAREEP-1A/20EP-1A/17SPARE20 A 100 1 20 ASPAREEP-1A/18EP-1A/15 EXTERIOR BLDG LTS 20 A 10.0301 20 ASPAREEP-1A/16EP-1A/13STAIR 2 LTS20 A 1 00.35120 A EXTERIOR BLDG LTS EP-1A/14EP-1A/11 MAIN LOBBY EM LTS 20 A 10.10.34 1 20 ASTAIR 1 LTSEP-1A/12EP-1A/9 TWO-WAY COMM HEADEND 20 A 10.180.581 20 A QUICK CARE EM LTS EP-1A/10EP-1A/7BLOCK HEATER20 A 1 0.180.181 20 A BATTERY CHARGER EP-1A/8EP-1A/5 ELEVATOR SHAFT LIGHTS 20 A 10.20.5 1 20 AFACPEP-1A/6EP-1A/3ACCESS CONTROL20 A 1001 20 ASTAIR DOOREP-1A/4EP-1A/1ACCESS CONTROL20 A 1 00.721 20 A RM 126, 133, 123, 122, 138, 143,... EP-1A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTEP-1AMAINELECTRICAL-1...EMDP 100.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:49 PME405SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNOTES:Heating0.07100.00%0.07Power41.3862.08%25.69Other4.5100.00%4.5TOTAL EST. DEMAND...268.56 AMotor0.65100.00%0.65TOTAL CONN....312.12 ALighting3.22100.00%3.22TOTAL EST. DEMAND:96.75HVAC62.62100.00%62.62TOTAL CONN. LOAD:112.44LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:318.25 A 304.62 A 317.65 ATOTAL LOAD:37.98 36.55 37.91DP2/41SPACE-- --00 -- --SPACEDP2/42DP2/39SPACE-- --00-- --SPACEDP2/40DP2/37SPACE-- -- 00-- --SPACEDP2/38DP2/35SPACE-- --00 -- --SPACEDP2/36DP2/33SPACE-- --00-- --SPACEDP2/34DP2/31SPACE-- -- 00-- --SPACEDP2/32DP2/29SPACE-- --00 -- --SPACEDP2/30DP2/27SPACE-- --00-- --SPACEDP2/28DP2/25SPACE-- -- 00-- --SPACEDP2/26DP2/23SPACE-- --00 -- --SPACEDP2/24DP2/21SPACE-- --00-- --SPACEDP2/22DP2/19SPACE-- -- 00-- --SPACEDP2/20DP2/174.6 4.6 DP2/18DP2/154.6 4.6DP2/16DP2/13ACCU-2E 45 A 34.6 4.63 45 A ACCU-2SDP2/14DP2/114.6 4.6 DP2/12DP2/94.6 4.6DP2/10DP2/7ACCU-2W 45 A 34.6 4.63 45 A ACCU-2NDP2/8DP2/59.89 9.64 DP2/6DP2/39.13 9.04DP2/4DP2/1PP2A 225 A 311.97 7.623 225 A PP2BDP2/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTDP2 IT/ELEC 243 MDP 400.00 A/MCB 3 4 120/208 Wye Surface 42K I-LINE Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Heating0.07100.00%0.07TOTAL EST. DEMAND...63.40 APower26.2869.03%18.14TOTAL CONN....85.99 AOther4.5100.00%4.5TOTAL EST. DEMAND:22.84Motor0.13100.00%0.13TOTAL CONN. LOAD:30.98LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:100.72 A 76.04 A 83.35 ATOTAL LOAD:11.97 9.13 9.89PP2A/53SPARE20 A 100 1 20 ASPAREPP2A/54PP2A/51SPARE20 A 1001 20 ASPAREPP2A/52PP2A/49SPARE20 A 1 001 20 ASPAREPP2A/50PP2A/47SPARE20 A 100 1 20 ASPAREPP2A/48PP2A/45SPARE20 A 1001 20 ASPAREPP2A/46PP2A/43SPARE20 A 1 001 20 ASPAREPP2A/44PP2A/410.04 0.13 1 20 A HWRP-1B PP2A/42PP2A/39BF-1B 20 A 20.04 2.25 PP2A/40PP2A/37 DENTAL OFFICE 231/EQUIP STO... 20 A 1 0.722.25230 A HWH-1BPP2A/38PP2A/35 DENTAL EQUIPMENT... 20 A 10.721.08 1 20 A DENTAL OFFICE 231... PP2A/36PP2A/33 Power Room 200C, 200B 20 A 10.540.721 20 A CIRCULATION CORR RCPT PP2A/34PP2A/31WAITING RCPT20 A 1 0.90.181 20 A WAITING WATER COOLER PP2A/32PP2A/29 CIRCULATION CORR RCPT 2 20 A 10.540.36 1 20 A CLEAN WORK/MED PREP 219... PP2A/30PP2A/27 TOILET 222. 224 RCPT 20 A 10.91.081 20 A CIRCULATION CORR RCPT 1 PP2A/28PP2A/25 VITALS ALCOVE 230 RCPT 20 A 1 0.180.361 20 ALAB 221 RCPTPP2A/26PP2A/23 CLERICAL OFFICE 203... 20 A 10.9 0.9 1 20 A CONSULT 206 RCPT PP2A/24PP2A/21 REGISTRATION 202 RCPT 2 20 A 1 0.9 0.72 1 20 A CLERICAL OFFICE 203... PP2A/22PP2A/19 MAIN LOBBY RCPT 2 20 A 1 0.541.261 20 A REGISTRATION 202 RCPT 1 PP2A/20PP2A/17 STAFF BREAK 208 WATER... 20 A 10.180.9 1 20 A CONSULT 204 RCPT PP2A/18PP2A/15 STAFF BREAK 208 WALL RCPT 20 A 10.540.181 20 A STAFF BREAK 208 COUNTER... PP2A/16PP2A/13 PHYSICIAN OFFICE/ DICTATION... 20 A 1 1.081.081 20 APower Room 209PP2A/14PP2A/11 NURSE WORKSTATION 3 RCPT 20 A 11.441.08 1 20 A NURSE WORKSTATION 2 RCPT PP2A/12PP2A/9 Power CORRIDOR 200D 20 A 10.360.181 20 A NURSE WORKSTATION COPIER PP2A/10PP2A/7 MAIN LOBBY RCPT 1 20 A 1 1.080.91 20 ATELEMED RCPTPP2A/8PP2A/5 MULTIPRUPOSE/ACTIVITY RCPT 20 A 10.541.08 1 20 A EDUCATION/CONFERENCE RCPT PP2A/6PP2A/3 STAFF BREAK COUNTER RCPT 20 A 1 0.36 0.36 1 20 A STAFF BREAK WALL RCPT PP2A/4PP2A/1OFFICE 238 RCPT20 A 1 0.90.541 20 A239/236 RCPTPP2A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP2A IT/ELEC 243 DP2 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Power15.183.11%12.55Other00.00%0TOTAL EST. DEMAND...65.94 AMotor0.52100.00%0.52TOTAL CONN....73.01 ALighting3.22100.00%3.22TOTAL EST. DEMAND:23.75HVAC7.46100.00%7.46TOTAL CONN. LOAD:26.3LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:63.54 A 77.17 A 82.13 ATOTAL LOAD:7.62 9.04 9.64PP2B/53SPARE20 A 100 1 20 ASPAREPP2B/54PP2B/51SPARE20 A 1001 20 ASPAREPP2B/52PP2B/49 EXTERIOR SIGNAGE 20 A 1 0.1801 20 ASPAREPP2B/50PP2B/47 DENTAL RM 225 CHAIR 20 A 10.50.18 1 20 ADENTAL RM LIGHTPP2B/48PP2B/45CUH-1C20 A 11.50.12PP2B/46PP2B/430.60.122 20 ABS-22 & DFC-12EPP2B/44PP2B/41BS-21 & DFC-05L,M,N & DFC-09E,F& DFC-15H20 A 20.6 0.58 PP2B/42PP2B/390.410.582 20 ABS-20 & DFC-18C & DFC-24C &DFC-30CPP2B/40PP2B/37BS-19 & DFC-05K & DFC-15G,N 20 A 20.41 0.52PP2B/38PP2B/350.48 0.522 20 ABS-18 & DFC-05J & DFC-07O &DFC-15M & DFC-18BPP2B/36PP2B/33BS-17 & DFC-09G,H & DFC-12D &DFC-24D20 A 20.48 0.53 PP2B/34PP2B/31 RM 202, 201, 204, 208, 206, 203,... 20 A 1 0.540.532 20 A BS-15,16 & DFC-24F & DFC-36APP2B/32PP2B/29 RM 218, 217, 216, 219, 220, 221,... 20 A 10.80.66 1 20 A CORR 228, 207, 214, 207A, 223... PP2B/30PP2B/27CORR 232, 200 LTS20 A 10.40.61 20 A Room 238, 242, 235, 241, 240, 23... PP2B/28PP2B/25 2ND FLR LOBBY LIGHTS 20 A 1 0.160.061 20 AIT/ELEC 243 LTSPP2B/26PP2B/23EXAM 211 RCPT20 A 10.90.9 1 20 AEXAM 210 RCPTPP2B/24PP2B/21EXAM 220 RCPT20 A 10.90.91 20 AEXAM 212 RCPTPP2B/22PP2B/19BREAK 208 MICRO20 A 1 0.180.361 20 ALAB 221 RCPTPP2B/20PP2B/17BREAK 208 RCPT20 A 10.180.9 1 20 AEXAM 215 RCPTPP2B/18PP2B/15 STAFF BREAK 208... 20 A 10.180.91 20 AEXAM 216 RCPTPP2B/16PP2B/13 RESPITE/LACTATION 240... 20 A 1 0.180.91 20 APower EXAM 217PP2B/14PP2B/11BREAK 242 RCPT20 A 10.180.18 1 20 A 239 REFRIGERATOR PP2B/12PP2B/9 STAFF BREAK ROOM... 20 A 10.1811 20 A BREAK 242 MICROWAVE PP2B/10PP2B/7 CLEAN WORK 312 RCPT 20 A 1 0.72 0.9 1 20 A BREAK 242 RCPT PP2B/8PP2B/5 Power EXAM (GYN) 218 20 A 11.081 1 20 ABREAK 242 MICROPP2B/6PP2B/3 ELEVATOR LOBBY WATER... 20 A 10.180.181 20 A SHARED REG COPIER PP2B/4PP2B/1 MEDITATION 241 RCPT 20 A 1 0.72 0.54 1 20 A 240/237 RCPT PP2B/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP2B IT/ELEC 243 DP2 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...32.45 APower8.16100.00%8.16TOTAL CONN....32.45 ALighting00.00%0TOTAL EST. DEMAND:11.69HVAC3.53100.00%3.53TOTAL CONN. LOAD:11.69LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:44.64 A 28.43 A 25.21 ATOTAL LOAD:5.31 3.36 3.03SBP-2A/41SPACE-- --00 -- --SPACESBP-2A/42SBP-2A/39SPACE-- --00-- --SPACESBP-2A/40SBP-2A/37SPACE-- -- 00-- --SPACESBP-2A/38SBP-2A/35SPACE-- --00 -- --SPACESBP-2A/36SBP-2A/33SPACE-- --00-- --SPACESBP-2A/34SBP-2A/31SPACE-- -- 00-- --SPACESBP-2A/32SBP-2A/29SPARE20 A 100 1 20 ASPARESBP-2A/30SBP-2A/27SPARE20 A 1001 20 ASPARESBP-2A/28SBP-2A/25SPARE20 A 1 001 20 ASPARESBP-2A/26SBP-2A/23SPARE20 A 100 1 20 ASPARESBP-2A/24SBP-2A/21SPARE20 A 1001 20 ASPARESBP-2A/22SBP-2A/19SPARE20 A 1 001 20 ASPARESBP-2A/20SBP-2A/17SPARE20 A 100 1 20 ASPARESBP-2A/18SBP-2A/15SPARE20 A 1001 20 ASPARESBP-2A/16SBP-2A/130.051.72SBP-2A/14SBP-2A/11AC-18D 15 A 20.05 1.722 20 A CU-18DSBP-2A/12SBP-2A/91.51.5SBP-2A/10SBP-2A/7IT/ELEC 243 L6-30R TWISTLOCK 30 A 21.5 1.52 30 A IT/ELEC 243 L6-30R TWISTLOCKSBP-2A/8SBP-2A/5 LAB 221 REFRIGERATOR 20 A 10.18 1.08 1 20 A DENTAL TREATMENT 225 RCPT SBP-2A/6SBP-2A/3DOOR OPERATOR20 A 10.180.181 20 ADOOR OPERATORSBP-2A/4SBP-2A/1IT/ELEC 243 RCPT20 A 1 0.360.181 20 AIT/ELEC 232 RCPTSBP-2A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTSBP-2A IT/ELEC 243 SBDP 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...7.83 APower1.5100.00%1.5TOTAL CONN....7.83 AOther00.00%0TOTAL EST. DEMAND:2.82Lighting1.32100.00%1.32TOTAL CONN. LOAD:2.82LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:20.12 A 4.62 A 0.00 ATOTAL LOAD:2.34 0.48 0EP-2A/29SPACE-- --00 -- --SPACEEP-2A/30EP-2A/27SPACE-- --00-- --SPACEEP-2A/28EP-2A/25SPACE-- -- 00-- --SPACEEP-2A/26EP-2A/23SPACE-- --00 -- --SPACEEP-2A/24EP-2A/21SPACE-- --00-- --SPACEEP-2A/22EP-2A/19SPACE-- -- 00-- --SPACEEP-2A/20EP-2A/17SPACE-- --00 -- --SPACEEP-2A/18EP-2A/15SPARE20 A 1001 20 ASPAREEP-2A/16EP-2A/13SPARE20 A 1 001 20 ASPAREEP-2A/14EP-2A/11SPARE20 A 100 1 20 ASPAREEP-2A/12EP-2A/9SPARE20 A 1001 20 ASPAREEP-2A/10EP-2A/7SPARE20 A 1 001 20 ASPAREEP-2A/8EP-2A/5SPARE20 A 100 1 20 ASPAREEP-2A/6EP-2A/32ND FLR EM LTS20 A 10.4801 20 ASPAREEP-2A/4EP-2A/1ACCESS CONTROL20 A 1 1.50.841 20 A2ND FLR EM LTSEP-2A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTEP-2A IT/ELEC 243 EMDP 100.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:52 PME406SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNOTES:Heating0.07100.00%0.07Power50.5859.89%30.29Other4.5100.00%4.5TOTAL EST. DEMAND...290.12 AMotor0.65100.00%0.65TOTAL CONN....346.43 ALighting4.21100.00%4.21TOTAL EST. DEMAND:104.52HVAC64.8100.00%64.8TOTAL CONN. LOAD:124.81LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:338.21 A 368.64 A 334.28 ATOTAL LOAD:40.52 44.17 40.11DP3/41SPACE-- --00 -- --SPACEDP3/42DP3/39SPACE-- --00-- --SPACEDP3/40DP3/37SPACE-- -- 00-- --SPACEDP3/38DP3/35SPACE-- --00 -- --SPACEDP3/36DP3/33SPACE-- --00-- --SPACEDP3/34DP3/31SPACE-- -- 00-- --SPACEDP3/32DP3/29SPACE-- --00 -- --SPACEDP3/30DP3/27SPACE-- --00-- --SPACEDP3/28DP3/25SPACE-- -- 00-- --SPACEDP3/26DP3/23SPACE-- --00 -- --SPACEDP3/24DP3/21SPACE-- --00-- --SPACEDP3/22DP3/19SPACE-- -- 00-- --SPACEDP3/20DP3/174.6 4.6 DP3/18DP3/154.6 4.6DP3/16DP3/13ACCU-3E 45 A 34.6 4.63 45 A ACCU-3SDP3/14DP3/114.6 4.6 DP3/12DP3/94.6 4.6DP3/10DP3/7ACCU-3W 45 A 34.6 4.63 45 A ACCU-3NDP3/8DP3/59.31 12.42 DP3/6DP3/313.8111.98DP3/4DP3/1PP3A 225 A 310.93 11.213 225 A PP3BDP3/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTDP3 ELEC/ DATA 323 MDP 400.00 A/MCB 3 4 120/208 Wye Surface 42K I-LINE Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Heating0.07100.00%0.07TOTAL EST. DEMAND...67.64 APower29.3467.04%19.67TOTAL CONN....94.49 AOther4.5100.00%4.5TOTAL EST. DEMAND:24.37Motor0.13100.00%0.13TOTAL CONN. LOAD:34.04LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:93.11 A 117.11 A 77.58 ATOTAL LOAD:10.93 13.81 9.31PP3A/53SPARE20 A 100 1 20 ASPAREPP3A/54PP3A/51SPARE20 A 1001 20 ASPAREPP3A/52PP3A/49SPARE20 A 1 001 20 ASPAREPP3A/50PP3A/47HWRP-1C20 A 10.130 1 20 ASPAREPP3A/48PP3A/450.042.25PP3A/46PP3A/43BF-1C 20 A 20.04 2.252 30 A HWH-1CPP3A/44PP3A/41 CENTRAL SOILED WORK 311... 20 A 10.90.54 1 20 ATOILETS RCPTPP3A/42PP3A/39 REGISTRATION 301 RCPT 2 20 A 10.360.541 20 A Power Room 598, 600 PP3A/40PP3A/37JANITOR RCPT20 A 1 0.180.721 20 ALAB DRAW 332 RCP PP3A/38PP3A/35 NURSE WORK 339 RCPT 20 A 10.540.18 1 20 ALAB 334 RCPTPP3A/36PP3A/33 NURSE WORK 339... 20 A 11.081.081 20 A NURSE WORK 339... PP3A/34PP3A/31 OFFICE 339 RCPT 120 A 1 0.90.541 20 AOFFICE 339 RCPT 2PP3A/32PP3A/29EXAM 329 RCPT20 A 10.720.54 1 20 A 339 COUNTER RCPT PP3A/30PP3A/27CORR RCPT 220 A 10.360.91 20 AEXAM 328 RCPTPP3A/28PP3A/25Power Space 61820 A 1 0.540.541 20 ACORR RCPT 1PP3A/26PP3A/23 Power Room 570, 571 20 A 10.360.36 1 20 APower Space 618PP3A/24PP3A/21OFFICE 317F RCPT20 A 11.261.621 20 ANURSE 324 RCPTPP3A/22PP3A/19 NURSE 317E WORKSTATION... 20 A 1 0.72 0.72 1 20 A NURSE 317E RCPTPP3A/20PP3A/17 NURSE 317E WORKSTATION... 20 A 1 0.72 0.72 1 20 A NURSE 317E WORKSTATION... PP3A/18PP3A/15 PROVIDER OFFICE 317 RCPT 120 A 1 1.26 1.08 1 20 A PROVIDER OFFICE 317 RCPT 2 PP3A/16PP3A/13 REGISTRATION WORKSTATION... 20 A 1 0.720.721 20 A REGISTRATION KIOSK RCPT PP3A/14PP3A/11 STAFF BREAK 301 RCPT 20 A 11.081.08 1 20 AOFFICE 301A RCPTPP3A/12PP3A/9 MAIN LOBBY RCPT 1 20 A 11.260.181 20 A STAFF BREAK 305 COUNTER... PP3A/10PP3A/7 REGISTRATION WORKSTATION... 20 A 1 1.080.721 20 A REGISTRATION 301 RCPT 1 PP3A/8PP3A/5 REGISTRATION WORKSTATION... 20 A 10.720.72 1 20 A REGISTRATION WORKSTATION... PP3A/6PP3A/3 MAIN LOBBY RCPT 2 20 A 10.360.181 20 A ELEVATOR WATER COOLER PP3A/4PP3A/1FIREPLACE RCPT20 A 1 0.180.361 20 A MAIN LOBBY FLR RCPT PP3A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP3A ELEC/ DATA 323 DP3 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Power21.2473.54%15.62Other00.00%0TOTAL EST. DEMAND...83.24 AMotor0.52100.00%0.52TOTAL CONN....98.84 ALighting4.21100.00%4.21TOTAL EST. DEMAND:29.99HVAC9.64100.00%9.64TOTAL CONN. LOAD:35.61LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:93.42 A 100.84 A 104.46 ATOTAL LOAD:11.21 11.98 12.42PP3B/53CUH-1D20 A 11.50 1 20 ASPAREPP3B/54PP3B/510.031.51 20 ACUH-1BPP3B/52PP3B/49AC-24C 15 A 20.03 0.37PP3B/50PP3B/470.46 0.37220 ABS-30 & DFC-05BG,BH,BI &DFC-09QPP3B/48PP3B/45BS-29 & DFC-05BJ & DFC-07M &DFC-09P & DFC-18I20 A 20.46 0.71 PP3B/46PP3B/430.480.71220 ABS-28 &DFC-05BA,BB,BC,BD,BE,BF &...PP3B/44PP3B/41BS-26,27 & DFC-05AX,AY,AZ &DFC-15O20 A 20.48 0.63 PP3B/42PP3B/390.620.632 20 A BS-25 & DFC-18K,L & DFC-36CPP3B/40PP3B/37BS-24 & DFC-05AR,AS,AT,AW &DFC-18J20 A 20.62 0.29PP3B/38PP3B/35 RMS 332, 334, 339B, 339, 339A,... 20 A 10.720.292 20 A BS-23 & DFC-05AU,AV & DFC-12PPP3B/36PP3B/33 3RD FLR WAITING LTS 20 A 10.260.581 20 A CORR 304-1, 304-2 LTS PP3B/34PP3B/31 RMS 311, 317B, 317E, 317, 619... 20 A 1 0.781.11 20 A RMS 301, 305, 309, 308, 307, 301... PP3B/32PP3B/29 EXAM/CONSULT 306 RCPT 20 A 10.90.77 1 20 A RMS 312, 324, 317F, 321, 320, 31... PP3B/30PP3B/27 EXAM/CONSULT 308 RCPT 20 A 10.90.91 20 A EXAM/CONSULT 307 RCPT PP3B/28PP3B/25 EXAM/CONSULT 316 20 A 1 0.90.91 20 A EXAM/CONSULT 309 RCPT PP3B/26PP3B/23EXAM 314 RC[T20 A 10.90.9 1 20 A EXAM/CONSULT 315 RCPT PP3B/24PP3B/21 EXAM/CONSULT 322 RCPT 20 A 10.90.91 20 APower Space 541PP3B/22PP3B/19 EXAM/CONSULT 320 RCPT 20 A 1 0.90.91 20 A EXAM/CONSULT 321 RCPT PP3B/20PP3B/17 EXAM/CONSULT 318 RCPT 20 A 10.90.9 1 20 A EXAM/CONSULT 319 RCPT PP3B/18PP3B/15EXAM 335 RCPT20 A 10.91.081 20 AEXAM 326 RCPTPP3B/16PP3B/13EXAM 328 RCPT20 A 1 0.90.91 20 AEXAM 331 RCPTPP3B/14PP3B/11Power Space 55720 A 10.360.9 1 20 AEXAM 327 RCPTPP3B/12PP3B/9 PATIENT VITALS ALCOVE RCPT 20 A 1 0.18 0.18 1 20 A REGIST 301 COPIER PP3B/10PP3B/7 NURSE WORK AREA 317B RCPT20 A 1 0.72 0.18 1 20 A STAFF BREAK 305...PP3B/8PP3B/5 NURSE WORK AREA 317B... 20 A1 0.72 0.72 1 20 A NURSE WORK AREA 317B... PP3B/6PP3B/3LAB 334 RCPT20 A 10.540.72120 A NURSE WORK AREA 317B... PP3B/4PP3B/1 STAFF BREAK 305 RCPT 20 A 1 0.360.181 20 ATOILET RCPTPP3B/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP3B ELEC/ DATA 323 DP3 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...33.95 ATOTAL CONN....33.95 APower8.7100.00%8.7TOTAL EST. DEMAND:12.23HVAC3.53100.00%3.53TOTAL CONN. LOAD:12.23LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:46.02 A 46.11 A 17.42 ATOTAL LOAD:5.07 5.08 2.09SBP-3A/41SPACE-- --00 -- --SPACESBP-3A/42SBP-3A/39SPACE-- --00-- --SPACESBP-3A/40SBP-3A/37SPACE-- -- 00-- --SPACESBP-3A/38SBP-3A/35SPACE-- --00 -- --SPACESBP-3A/36SBP-3A/33SPACE-- --00-- --SPACESBP-3A/34SBP-3A/31SPACE-- -- 00-- --SPACESBP-3A/32SBP-3A/29SPACE-- --00 -- --SPACESBP-3A/30SBP-3A/27SPARE20 A 1001 20 ASPARESBP-3A/28SBP-3A/25SPARE20 A 1 001 20 ASPARESBP-3A/26SBP-3A/23SPARE20 A 100 1 20 ASPARESBP-3A/24SBP-3A/21SPARE20 A 1001 20 ASPARESBP-3A/22SBP-3A/19SPARE20 A 1 001 20 ASPARESBP-3A/20SBP-3A/17SPARE20 A 100 1 20 ASPARESBP-3A/18SBP-3A/151.7201 20 ASPARESBP-3A/16SBP-3A/13CU-18E 20 A 21.72 0.05SBP-3A/14SBP-3A/111.5 0.052 15 A AC-18ESBP-3A/12SBP-3A/9ELEC/DATA 323 L6-30R TWIST 30 A 21.5 1.5 SBP-3A/10SBP-3A/7ELEC/DATA RCPT20 A 1 0.181.52 30 A ELEC/DATA 323 L6-30R TWISTSBP-3A/8SBP-3A/5 LAB 334 REFRIGERATOR 20 A1 0.18 0.36 1 20 A PATIENT TOILET RCPT SBP-3A/6SBP-3A/3Power Space 57320 A 10.180.181 20 A 339 CRASH CART RCPT SBP-3A/4SBP-3A/1ELEC 329 RCPT20 A 1 0.361.261 20 A EXAM/TREATMENT 303 RCPT SBP-3A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTSBP-3A ELEC/ DATA 323 SBDP 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQODType 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...5.27 APower0.5100.00%0.5TOTAL CONN....5.27 AOther00.00%0TOTAL EST. DEMAND:1.9Lighting1.4100.00%1.4TOTAL CONN. LOAD:1.9LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:9.35 A 8.85 A 0.00 ATOTAL LOAD:0.98 0.92 0EP-3A/29SPACE-- --00 -- --SPACEEP-3A/30EP-3A/27SPACE-- --00-- --SPACEEP-3A/28EP-3A/25SPACE-- -- 00-- --SPACEEP-3A/26EP-3A/23SPACE-- --00 -- --SPACEEP-3A/24EP-3A/21SPACE-- --00-- --SPACEEP-3A/22EP-3A/19SPACE-- -- 00-- --SPACEEP-3A/20EP-3A/17SPACE-- --00 -- --SPACEEP-3A/18EP-3A/15SPARE20 A 1001 20 ASPAREEP-3A/16EP-3A/13SPARE20 A 1 001 20 ASPAREEP-3A/14EP-3A/11SPARE20 A 100 1 20 ASPAREEP-3A/12EP-3A/9SPARE20 A 1001 20 ASPAREEP-3A/10EP-3A/7SPARE20 A 1 001 20 ASPAREEP-3A/8EP-3A/5SPARE20 A 100 1 20 ASPAREEP-3A/6EP-3A/3 RMS 300, 301, 305, 317A, 317E,... 20 A 10.9201 20 ASPAREEP-3A/4EP-3A/1ACCESS CONTROL20 A 1 0.50.481 20 A RMS 334, 304-1, 304-2, 339, 339A... EP-3A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTEP-3A ELEC/ DATA 323 EMDP 100.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:55 PME407SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNOTES:Heating0.07100.00%0.07Power31.1466.06%20.57Other4.5100.00%4.5TOTAL EST. DEMAND...207.62 AMotor0.46100.00%0.46TOTAL CONN....236.96 ALighting2.95100.00%2.95TOTAL EST. DEMAND:74.8HVAC46.25100.00%46.25TOTAL CONN. LOAD:85.37LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:262.36 A 215.17 A 240.70 ATOTAL LOAD:31.07 25.82 28.48DP4/41SPACE-- --00 -- --SPACEDP4/42DP4/39SPACE-- --00-- --SPACEDP4/40DP4/37SPACE-- -- 00-- --SPACEDP4/38DP4/35SPACE-- --00 -- --SPACEDP4/36DP4/33SPACE-- --00-- --SPACEDP4/34DP4/31SPACE-- -- 00-- --SPACEDP4/32DP4/29SPACE-- --00 -- --SPACEDP4/30DP4/27SPACE-- --00-- --SPACEDP4/28DP4/25SPACE-- -- 00-- --SPACEDP4/26DP4/23SPACE-- --00 -- --SPACEDP4/24DP4/21SPACE-- --00-- --SPACEDP4/22DP4/19SPACE-- -- 00-- --SPACEDP4/20DP4/174.6 0 -- -- SPACE DP4/18DP4/154.6 0 -- -- SPACE DP4/16DP4/13ACCU-4S 45 A 34.6 0 -- -- SPACE DP4/14DP4/114.6 4.6 DP4/12DP4/94.6 4.6DP4/10DP4/7ACCU-4N 45 A 34.6 4.63 45 A ACCU-4EDP4/8DP4/58.73 5.96 DP4/6DP4/36.29 5.74DP4/4DP4/1PP4A 225 A 310.03 7.263 225 A PP4BDP4/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTDP4 ELEC/DATA 430 MDP 400.00 A/MCB 3 4 120/208 Wye Surface 42K I-LINE Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Heating0.07100.00%0.07TOTAL EST. DEMAND...55.15 APower20.3474.58%15.17TOTAL CONN....69.50 AOther4.5100.00%4.5TOTAL EST. DEMAND:19.87Motor0.13100.00%0.13TOTAL CONN. LOAD:25.04LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:86.68 A 52.38 A 75.88 ATOTAL LOAD:10.03 6.29 8.73PP4A/41SPARE20 A 100 1 20 ASPAREPP4A/42PP4A/39SPARE20 A 1001 20 ASPAREPP4A/40PP4A/37SPARE20 A 1 001 20 ASPAREPP4A/38PP4A/35SPARE20 A 100 1 20 ASPAREPP4A/36PP4A/330.040.131 20 AHWRP-1DPP4A/34PP4A/31BF-1D 20 A 20.04 2.25PP4A/32PP4A/29 4TH FLR CORR RCPT 20 A 10.92.25230 A HWH-1DPP4A/30PP4A/27SOILED 420 RCPT20 A 10.180.91 20 A MEN'S CIRCULATION CORR RCPT PP4A/28PP4A/25storage 421 rcpt20 A 1 0.720.541 20 A SOILED WORKROOM 420 RCPT PP4A/26PP4A/23 MEN'S WAIT 418 RCPT 20 A 10.90.54 1 20 A CLEAN WORKROOM 419 RCPT PP4A/24PP4A/21 REGISTRATION 402... 20 A 10.721.261 20 A CONFERENCE 433 RCPT PP4A/22PP4A/19TOILETS 400 RCPT20 A 1 1.081.081 20 A REGISTRATION 402... PP4A/20PP4A/17 IMAGING WAITING 401 RCPT 2 20 A 11.260.18 1 20 A ELEVATO LOBBY WATER... PP4A/18PP4A/15 WAITING 401 WATER COOLER 20 A 10.180.541 20 A IMAGING WAITING 401 RCPT 1 PP4A/16PP4A/13TOILET 407B RCPT20 A 1 0.361.081 20 A PRACTICE MGR 403 RCPT PP4A/14PP4A/11TOILET/EVS RCPT20 A 10.541.26 1 20 ACONSULT RCPTPP4A/12PP4A/9 NURSE/TECH 411 WORKSTATIO... 20 A 1 0.72 0.72 1 20 A NURSE/TECH STATION 411... PP4A/10PP4A/7 RESULTS ALCOVE RCPT 20 A 1 0.541.081 20 A NURSE/TECH 411 WORKSATION... PP4A/8PP4A/5 CIRCULATION LOBBY RCPT 2 20 A 10.180.72 1 20 A HOLDING BAY WORKSTATION... PP4A/6PP4A/3 PATIENT TOILETS RCPT 20 A 10.360.541 20 A CIRCULATION LOBBY RCPT 1 PP4A/4PP4A/1 IMAGING IT 429 RCPT 20 A 1 0.18 1.08 1 20 A OFFICE 428 RCPT PP4A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP4A ELEC/DATA 430 DP4 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Power10.896.30%10.4Other00.00%0TOTAL EST. DEMAND...51.52 AMotor0.33100.00%0.33TOTAL CONN....52.63 ALighting2.95100.00%2.95TOTAL EST. DEMAND:18.56HVAC4.88100.00%4.88TOTAL CONN. LOAD:18.96LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:60.76 A 47.87 A 49.90 ATOTAL LOAD:7.26 5.74 5.96PP4B/41SPARE20 A 100 1 20 ASPAREPP4B/42PP4B/39SPARE20 A 1001 20 ASPAREPP4B/40PP4B/37SPARE20 A 1 00.25PP4B/38PP4B/350.37 0.252 20 A BS-41,42 & DFC-05X & DFC-07PPP4B/36PP4B/33BS-40 & DFC-05U & DFC-12K,L,S 20 A 20.37 0.37 PP4B/34PP4B/310.440.372 20 A BS-39 & DFC-07I,N,Q & DFC-12JPP4B/32PP4B/29BS-38 & DFC-07F & DFC-12H,I &DFC-15L20 A 20.44 0.37 PP4B/30PP4B/270.250.372 20 A BS-37 & DFC-05Q,R,S,TPP4B/28PP4B/25BS-35,36 & DFC-07H & DFC-09J 20 A 20.25 0.56PP4B/26PP4B/23 RMS 425, 415, 424, 427, 412, 411,... 20 A 1 0.91 0.562 20 ABS-33,34 & DFC-12F,G & DFC-18E& DFC-PP4B/24PP4B/21 RMS 401, 405, 407C, 407D, 407A,... 20 A 10.891.151 20 A RMS 420, 419, 432, 416, 422, 423,... PP4B/22PP4B/19 MAMMOGRAPHY 431 RCPT 20 A 1 1.080.361 20 A HOLDING BAY 412 RCPT PP4B/20PP4B/17SUB-WAIT 40920 A 10.180.18 1 20 A WAITING 401 FIREPLACE PP4B/18PP4B/15NURSE 411 RCPT20 A 10.180.181 20 ASUB-WAIT 409PP4B/16PP4B/13 HOLDING 412B RCPT 20 A 1 0.720.721 20 A HOLDING 412A RCPT PP4B/14PP4B/11 DEXASCAN 432 RCPT 20 A 10.360.36 1 20 A PATIENT TOILETS RCPT PP4B/12PP4B/9 ULTRASOUND (GUIDED BIOPSY... 20 A 10.360.541 20 A DEXASCAN 432 RCPT PP4B/10PP4B/7 ULTRASOUND 424 RCPT 20 A 1 0.360.91 20 A ULTRASOUND 415 RCPT PP4B/8PP4B/5 ULTRASOUND 423 RCPT 20 A 10.91.08 1 20 A ULTRASOUND 424 RCPT PP4B/6PP4B/3 READING ROOM 426... 20 A 10.720.361 20 A ULTRASOUND (PoS) 423 RCPT PP4B/4PP4B/1 ELEC/DATA 430 RCPT 20 A 1 0.540.721 20 A READING ROOM 426... PP4B/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP4B ELEC/DATA 430 DP4 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Power26.9468.56%18.47Other00.00%0TOTAL EST. DEMAND...118.55 AMotor0.37100.00%0.37TOTAL CONN....142.06 ALighting1.44100.00%1.44TOTAL EST. DEMAND:42.71HVAC22.42100.00%22.42TOTAL CONN. LOAD:51.18LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:134.76 A 144.11 A 150.12 ATOTAL LOAD:16.17 17.14 17.86SBP-4A/53SPARE20 A 100 1 20 ASPARESBP-4A/54SBP-4A/51SPARE20 A 1001 20 ASPARESBP-4A/52SBP-4A/49SPARE20 A 1 001 20 ASPARESBP-4A/50SBP-4A/471.72 1.72 SBP-4A/48SBP-4A/45CU-18F 20 A 21.72 1.722 20 A CU-18GSBP-4A/46SBP-4A/430.50.1SBP-4A/44SBP-4A/41BS-32 & DFC-05P,AO & DFC-15I,J 20 A 20.5 0.1215 A AC-18F,GSBP-4A/42SBP-4A/390.484.6SBP-4A/40SBP-4A/37BS-31 & DFC05O & DFC-07E &DFC-09I & DFC-30B20 A 20.48 4.6SBP-4A/38SBP-4A/35 BREAK 443 COUNTER RCPT 20 A 1 0.36 4.63 45 A ACCU-4WSBP-4A/36SBP-4A/33 TOILET/EVS 439,444,445 RCPT 20 A 10.540.361 20 ABREAK 443 RCPTSBP-4A/34SBP-4A/311.51.5SBP-4A/32SBP-4A/29IT 429 L6-30R TWIST 30 A 21.5 1.52 30 A IT 429 L6-30R TWISTSBP-4A/30SBP-4A/271.51.5SBP-4A/28SBP-4A/25ELEC/DATA 430 L6-30R TWIST 30 A 21.5 1.52 30 A ELEC/DATA 430 L6-30R TWISTSBP-4A/26SBP-4A/23 CLEAN WORKROOM 437 RCPT 20 A 11.080.36 1 20 A ELEC/DATA 430 RCPT SBP-4A/24SBP-4A/21 PROCEDURE ROOM 440 RCPT 20 A 1 0.72 0.54 1 20 A PROCEDURE ROOM 440 RCPT SBP-4A/22SBP-4A/19 PROCEDURE ROOM 441 RCPT 20 A 1 0.54 0.54 1 20 A PROCEDURE ROOM 441 RCPT SBP-4A/20SBP-4A/17 PROCEDURE RM 442 RCPT 20 A1 0.54 0.54 1 20 A PROCEDURE RM 442 SBP-4A/18SBP-4A/15 BREAK 443 REFRIGERATOR 20 A 10.180.541 20 A PROCEDURE ROOM 442 RCPT SBP-4A/16SBP-4A/13 PROCEDURE ROOM 440 RCPT 20 A 1 0.54 0.54 1 20 A PROCEDURE ROOM 441 RCPT SBP-4A/14SBP-4A/11 RADIOGRAPHY 416 RCPT 20 A 10.540.72 1 20 A RADIOGRAPHY 416... SBP-4A/12SBP-4A/9 SOILED WORKROOM 438 RCPT 20 A 1 0.9 0.42 1 20 A CORR 400, 400C LTS SBP-4A/10SBP-4A/7 WAITING 434 RCPT20 A 1 1.080.361 20 A CIRCULATION CORR RCPTSBP-4A/8SBP-4A/5 Power PROVIDER OFFICE 436A... 20 A 1 1.08 1.02 1 20 A MULTI DISCIPLINE RMS LTS SBP-4A/6SBP-4A/3DOOR OPERATOR20 A 10.181.261 20 A RECEPTION 436 RCPT SBP-4A/4SBP-4A/1 MAMMOGRAPHY 427 RCPT 20 A 1 0.720.181 20 ADOOR OPERATORSBP-4A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTSBP-4A ELEC/DATA 430 SBDP 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...5.05 APower0.5100.00%0.5TOTAL CONN....5.05 AOther00.00%0TOTAL EST. DEMAND:1.82Lighting1.32100.00%1.32TOTAL CONN. LOAD:1.82LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:8.65 A 8.82 A 0.00 ATOTAL LOAD:0.9 0.92 0EP-4A/29SPACE-- --00 -- --SPACEEP-4A/30EP-4A/27SPACE-- --00-- --SPACEEP-4A/28EP-4A/25SPACE-- -- 00-- --SPACEEP-4A/26EP-4A/23SPACE-- --00 -- --SPACEEP-4A/24EP-4A/21SPACE-- --00-- --SPACEEP-4A/22EP-4A/19SPACE-- -- 00-- --SPACEEP-4A/20EP-4A/17SPACE-- --00 -- --SPACEEP-4A/18EP-4A/15SPARE20 A 1001 20 ASPAREEP-4A/16EP-4A/13SPARE20 A 1 001 20 ASPAREEP-4A/14EP-4A/11SPARE20 A 100 1 20 ASPAREEP-4A/12EP-4A/9SPARE20 A 1001 20 ASPAREEP-4A/10EP-4A/7SPARE20 A 1 001 20 ASPAREEP-4A/8EP-4A/5SPARE20 A 100 1 20 ASPAREEP-4A/6EP-4A/3 RMS 425, 426, 422, 412, 411, 418,... 20 A 10.520.41 20 A RMS 401, 405, ST3-5-1, 406, 402,... EP-4A/4EP-4A/1ACCESS CONTROL20 A 1 0.50.41 20 A RMS 433, 400, 435, 443, 434, 436,... EP-4A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTEP-4A ELEC/DATA 430 EMDP 100.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:58:59 PME408SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNOTES:Heating0.07100.00%0.07Power57.0658.76%33.53Other4.5100.00%4.5TOTAL EST. DEMAND...323.76 AMotor0.65100.00%0.65TOTAL CONN....389.07 ALighting4.08100.00%4.08TOTAL EST. DEMAND:116.64HVAC73.81100.00%73.81TOTAL CONN. LOAD:140.17LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:399.77 A 382.63 A 386.79 ATOTAL LOAD:47.91 45.92 46.35DP5/41SPACE-- --00 -- --SPACEDP5/42DP5/39SPACE-- --00-- --SPACEDP5/40DP5/37SPACE-- -- 00-- --SPACEDP5/38DP5/35SPACE-- --00 -- --SPACEDP5/36DP5/33SPACE-- --00-- --SPACEDP5/34DP5/31SPACE-- -- 00-- --SPACEDP5/32DP5/29SPACE-- --00 -- --SPACEDP5/30DP5/27SPACE-- --00-- --SPACEDP5/28DP5/25SPACE-- -- 00-- --SPACEDP5/26DP5/23SPACE-- --00 -- --SPACEDP5/24DP5/21SPACE-- --00-- --SPACEDP5/22DP5/19SPACE-- -- 00-- --SPACEDP5/20DP5/174.6 4.6 DP5/18DP5/154.6 4.6DP5/16DP5/13ACCU-5E 20 A 34.6 4.63 45 A ACCU-5SDP5/14DP5/114.6 4.6 DP5/12DP5/94.6 4.6DP5/10DP5/7ACCU-5W 45 A 34.6 4.63 45 A ACCU-5NDP5/8DP5/512.93 15.03 DP5/6DP5/312.7814.75DP5/4DP5/1PP5A 225 A 312.42 17.13 225 A PP5BDP5/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTDP5 IT/ELEC 523 MDP 400.00 A/MCB 3 4 120/208 Wye Surface 42K I-LINE Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Heating0.07100.00%0.07Power29.3467.04%19.67TOTAL EST. DEMAND...78.97 AOther4.5100.00%4.5TOTAL CONN....105.81 AMotor0.13100.00%0.13TOTAL EST. DEMAND:28.45Lighting4.08100.00%4.08TOTAL CONN. LOAD:38.12LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:103.46 A 106.92 A 108.21 ATOTAL LOAD:12.42 12.78 12.93PP5A/83SPACE-- --00 -- --SPACEPP5A/84PP5A/81SPACE-- --00-- --SPACEPP5A/82PP5A/79SPACE-- -- 00-- --SPACEPP5A/80PP5A/77SPACE-- --00 -- --SPACEPP5A/78PP5A/75SPACE-- --00-- --SPACEPP5A/76PP5A/73SPACE-- -- 00-- --SPACEPP5A/74PP5A/71SPACE-- --00 -- --SPACEPP5A/72PP5A/69SPACE-- --00-- --SPACEPP5A/70PP5A/67SPARE20 A 1 001 20 ASPAREPP5A/68PP5A/65SPARE20 A 100 1 20 ASPAREPP5A/66PP5A/63SPARE20 A 1001 20 ASPAREPP5A/64PP5A/61SPARE20 A 1 001 20 ASPAREPP5A/62PP5A/59SPARE20 A 100 1 20 ASPAREPP5A/60PP5A/57SPARE20 A 1001 20 ASPAREPP5A/58PP5A/55ROOF RCPT20 A 1 0.1801 20 ASPAREPP5A/56PP5A/53ROOF RCPT20 A 10.180.18 1 20 AROOF RCPTPP5A/54PP5A/510.040.131 20 AHWRP-1EPP5A/52PP5A/49BF-1E 20 A 20.04 2.25PP5A/50PP5A/47RMS 501, 502 LTS20 A 10.242.252 30 AHWH-1EPP5A/48PP5A/45 RMS 517B, 517E, 517, 517B, 517... 20 A 10.71.111 20 A RMS 511, 502, 505, 509, 508, 507,... PP5A/46PP5A/43 RMS 504-2, 504BB, 504-1, 510 LTS 20 A 1 0.54 0.77 1 20 A RMS 512, 524, 517F, 521, 520, 51... PP5A/44PP5A/41 REGISTRATION RCPT 1 20 A 10.361.08 1 20 A REGISTRATION WORKSTATION... PP5A/42PP5A/39 REGISTRATION WORKSTATION... 20 A 10.721.081 20 A REGISTRATION WORKSTATION... PP5A/40PP5A/37 WAITING WATER COOLER 20 A 1 0.180.91 20 A REGISTRATION WORKSTATION... PP5A/38PP5A/35TOILETS 501A/B20 A 10.90.72 1 20 A WAITING 501 RCPT 2 PP5A/36PP5A/33 WAITING 501 RCPT 1 20 A 11.260.181 20 APower Space 594PP5A/34PP5A/31 TOILETS 535A/536 RCPT 20 A 1 0.54 0.72 1 20 A RMS 532, 534, 539B, 539, 539A,... PP5A/32PP5A/29CIRC 504 RCPT20 A 10.720.72 1 20 A510/5100 RCPTPP5A/30PP5A/27 NURSE 517B WORKSTATION... 20 A 1 0.72 0.72 1 20 A NURSE 517B WORKSTATION... PP5A/28PP5A/25 CLEAN WORK 512 RCPT 20 A 1 0.90.361 20 A NURSE AREA 517D RCPTPP5A/26PP5A/23 CIRCULATION CORR 504 RCPT 20 A 10.540.18 1 20 AEWEWPP5A/24PP5A/21 NURSE WORK 539... 20 A 11.080.721 20 A TRIAGE NURSE 539B RCPT PP5A/22PP5A/19 PROVIDER OFFICE 539A... 20 A 1 0.72 1.08 1 20 A NURSE WORK 539... PP5A/20PP5A/17 NURSE WORK 539 CART RCPT 20 A 10.181.44 1 20 A PROVIDER OFFICE 539A... PP5A/18PP5A/15TOILET 527 RCPT20 A 10.180.541 20 A NURSE WORK 536 RCPT PP5A/16PP5A/13 STAFF CIRCULATION CORR... 20 A 1 0.360.361 20 A TOILETS 525/526 RCPT PP5A/14PP5A/11 NURSE AREA 517E RCPT 20 A 10.721.08 1 20 A TRIAGE NURSE 524 RCPT PP5A/12PP5A/9 PROVIDER OFFICE 517F... 20 A 10.721.081 20 A PROVIDER OFFICE 317F... PP5A/10PP5A/7 NURSE AREA 517E... 20 A 1 0.720.721 20 A NURSE AREA 517E...PP5A/8PP5A/5 STAFF CIRCULATION CORR RCPT 20 A 10.720.72 1 20 A NURSE AREA 517E...PP5A/6PP5A/3 PROVIDER OFFICE 517A... 20 A 11.080.721 20 A PROVIDER OFFICE 517A... PP5A/4PP5A/1 STAFF BREAK AREA 505 RCPT20 A 1 0.72 0.36 1 20 A STAFF BREAK AREA 505... PP5A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP5A IT/ELEC 523 DP5 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...105.56 APower27.7268.04%18.86TOTAL CONN....130.15 AMotor0.52100.00%0.52TOTAL EST. DEMAND:38.03HVAC18.65100.00%18.65TOTAL CONN. LOAD:46.89LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:142.89 A 122.95 A 125.62 ATOTAL LOAD:17.1 14.75 15.03PP5B/83SPACE-- --00 -- --SPACEPP5B/84PP5B/81SPACE-- --00-- --SPACEPP5B/82PP5B/79SPACE-- -- 00-- --SPACEPP5B/80PP5B/77SPACE-- --00 -- --SPACEPP5B/78PP5B/75SPACE-- --00-- --SPACEPP5B/76PP5B/73SPACE-- -- 00-- --SPACEPP5B/74PP5B/71SPARE20 A 100 1 20 ASPAREPP5B/72PP5B/69SPARE20 A 1001 20 ASPAREPP5B/70PP5B/67SPARE20 A 1 001 20 ASPAREPP5B/68PP5B/65SPARE20 A 100 1 20 ASPAREPP5B/66PP5B/63EF-156020 A 11.663.45PP5B/64PP5B/611.73.452 20 ACU-48APP5B/62PP5B/59CU-24A 20 A 21.7 0.03 PP5B/60PP5B/570.030.032 15 AAC-24BPP5B/58PP5B/55AC-24A 15 A 20.03 0.37PP5B/56PP5B/530.29 0.37220 ABS-50 & DFC-05AK,AL,AM &DFC-09NPP5B/54PP5B/51BS-49 & DFC-05AN & DFC-09K,M 20 A 20.29 0.52 PP5B/52PP5B/490.710.52220 ABS-48 & DFC-05AD & DFC-07G &DFC-15P & DFC-18MPP5B/50PP5B/47BS-47 &DFC-05AF,AG,AH,AI,AJ,AQ &...20 A 20.71 0.76 PP5B/48PP5B/450.290.76220 ABS-45,46 & DFC-05AE &DFC-18G,H & DFC-36BPP5B/46PP5B/43BS-44 & DFC-05AB,AC & DFC-12N 20 A 20.29 0.62PP5B/44PP5B/41EXAM 506 RCPT20 A 11.260.62220 ABS-43 & DFC-05Y,Z,AA,AP &DFC-07J & DFC-18FPP5B/42PP5B/39EXAM 508 RCPT20 A 10.720.541 20 AEXAM 507 RCPTPP5B/40PP5B/37EXAM516 RCPT20 A 1 0.90.721 20 AEXAM 509 RCPTPP5B/38PP5B/35EXAM 514 RCPT20 A 10.90.9 1 20 AEXAM 515 RCPTPP5B/36PP5B/33EXAM 522 RCPT20 A 10.90.91 20 AEXAM 513 RCPTPP5B/34PP5B/31EXAM 520 RCPT20 A 1 0.90.91 20 AEXAM 521 RCPTPP5B/32PP5B/29EXAM 518 RCPT20 A 10.90.9 1 20 AEXAM 519 RCPTPP5B/30PP5B/27EXAM 535 RCPT20 A 10.90.721 20 AEXAM 526 RCPTPP5B/28PP5B/25EXAM 538 RCPT20 A 1 0.90.91 20 AEXAM 531 RCPTPP5B/26PP5B/23EXAM 529 RCPT20 A 10.720.9 1 20 AEXAM 537 RCPTPP5B/24PP5B/21NURSE 517B RCPT20 A 10.720.721 20 AEXAM 528 RCPTPP5B/22PP5B/19 EXTERIOR SIGNAGE EAST 20 A 1 1.50.181 20 A DRINKING FOUNTAIN PP5B/20PP5B/17 EXTERIOR SIGNAGE 20 A 11.51.51 20 A EXTERIOR SIGNAGE SOUTH PP5B/18PP5B/15 STAFF BREAK 505 RCPT 20 A 10.180.181 20 A STAFF BREAK 505 MICRO PP5B/16PP5B/13 NURSE WORK 539 RCPT 20 A 1 0.54 0.18 1 20 A Power STAFF BREAK AREA 505... PP5B/14PP5B/11LAB 534 RCPT20 A 10.540.18 1 20 ALAB 534 RCPTPP5B/12PP5B/9 REGISTRATION 502 COPIER 20 A 10.180.721 20 ARM 533,532 RCPTPP5B/10PP5B/7ROOF RCPT 520 A 1 0.180.181 20 AIT/ELEC 523 RCPTPP5B/8PP5B/5ROOF RCPT 320 A 10.180.18 1 20 AROOF RCPT 4PP5B/6PP5B/3ROOF RCPT 120 A 10.180.181 20 AROOF RCPT 2PP5B/4PP5B/1OFFICE 502A RCPT20 A 1 1.260.181 20 A PATIENT ALCOVE RCPT PP5B/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTPP5B IT/ELEC 523 DP5 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:Power7.08100.00%7.08TOTAL EST. DEMAND...115.89 AOther00.00%0TOTAL CONN....115.89 ALighting0.03100.00%0.03TOTAL EST. DEMAND:41.75HVAC34.64100.00%34.64TOTAL CONN. LOAD:41.75LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:106.94 A 110.41 A 131.49 ATOTAL LOAD:12.83 13.19 15.72SBP-5A/41SPACE-- --00 -- --SPACESBP-5A/42SBP-5A/39SPACE-- --00-- --SPACESBP-5A/40SBP-5A/37SPACE-- -- 00-- --SPACESBP-5A/38SBP-5A/35SPACE-- --00 -- --SPACESBP-5A/36SBP-5A/33SPARE20 A 1001 20 ASPARESBP-5A/34SBP-5A/31SPARE20 A 1 001 20 ASPARESBP-5A/32SBP-5A/29SPARE20 A 100 1 20 ASPARESBP-5A/30SBP-5A/27SPARE20 A 1001 20 ASPARESBP-5A/28SBP-5A/25SPARE20 A 1 001 20 ASPARESBP-5A/26SBP-5A/234.6 4.6 SBP-5A/24SBP-5A/214.64.6SBP-5A/22SBP-5A/19ACCU-1E 45 A 34.6 4.63 45 A ACCU-1NSBP-5A/20SBP-5A/171.72 1.72 SBP-5A/18SBP-5A/15CU-18H 20 A 21.72 1.722 20 A CU-18ISBP-5A/16SBP-5A/130.050.05SBP-5A/14SBP-5A/11AC-18H 15 A 20.05 0.052 15 A AC-18ISBP-5A/12SBP-5A/9 ELEVATOR TOP RCPT 20 A 10.180.031 20 A ELEVATOR CONTROL ROOM 50... SBP-5A/10SBP-5A/71.51.5SBP-5A/8SBP-5A/5IT/ELEC 523 L6-30R TWIST 30 A 21.5 1.52 30 A IT/ELEC 523 L6-30R TWISTSBP-5A/6SBP-5A/3 ELEVATOR CONTROL ROOM 50... 20 A 10.180.181 20 ALAB 532 RCPTSBP-5A/4SBP-5A/1IT/ELEC 523 RCPT20 A 1 0.360.181 20 A ELEV B SHAFT RCPT SBP-5A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTSBP-5A IT/ELEC 523 SBDP 225.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:NOTES:TOTAL EST. DEMAND...6.27 APower0.86100.00%0.86TOTAL CONN....6.27 AOther00.00%0TOTAL EST. DEMAND:2.26Lighting1.4100.00%1.4TOTAL CONN. LOAD:2.26LOAD CLASSIFICATIONCONNECTED... DEMAND FACTOR ESTIMATED...PANEL TOTALSTOTAL AMPS:8.88 A 8.38 A 3.00 ATOTAL LOAD:0.98 0.92 0.36EP-5A/29SPACE-- --00 -- --SPACEEP-5A/30EP-5A/27SPACE-- --00-- --SPACEEP-5A/28EP-5A/25SPACE-- -- 00-- --SPACEEP-5A/26EP-5A/23SPACE-- --00 -- --SPACEEP-5A/24EP-5A/21SPACE-- --00-- --SPACEEP-5A/22EP-5A/19SPACE-- -- 00-- --SPACEEP-5A/20EP-5A/17SPACE-- --00 -- --SPACEEP-5A/18EP-5A/15SPARE20 A 1001 20 ASPAREEP-5A/16EP-5A/13SPARE20 A 1 001 20 ASPAREEP-5A/14EP-5A/11SPARE20 A 100 1 20 ASPAREEP-5A/12EP-5A/9SPARE20 A 1001 20 ASPAREEP-5A/10EP-5A/7SPARE20 A 1 001 20 ASPAREEP-5A/8EP-5A/5BDA20 A 10.180.18 1 20 ABDAEP-5A/6EP-5A/3 RMS 505, 517A, 517E, 517F, 524,... 20 A 1 0.52 0.4 1 20 A RMS 501, 502, 503, 501A, 501B E... EP-5A/4EP-5A/1ACCESS CONTROL20 A 1 0.50.481 20 A RMS 534, 504-2, 504BB, 504-1, 28... EP-5A/2CKTDESCRIPTION TRIP POLESABCABCPOLES TRIP DESCRIPTIONCKTEP-5A IT/ELEC 523 EMDP 100.00 A/MLO 3 4 120/208 Wye Surface 42K NQOD Type 1NAME LOCATION SOURCE RATING (AMPS) PHASE WIRE VOLTAGE MOUNTINGUL LISTINGINT. RATING(RMS SYM....DESIGNMAKESQ-DNEMATYPE200% NEUTRALHINGED TRIMXFEED THRU LUGSISOLAT. GND BUSSE RATEDCOMPUTER GRADESUB FEED BRK.COLUMN WIDTHPANELBOARD SCHEDULENOTES:REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 91.5"FLOORTOP VIEW - FRONTFLOOR PLAN - FRONT54"36"42"36"168"31"19.5015.2537"19.5015.2531"36"38.7537"42"38.7531"19.5015.2531"36"38.7549"19.5015.2549"54"38.7536" 42" 36"54"48"3.0"48"NOTES:1. AT POINT OF ENTRNACE TO FACILITY. PROVIDE SOLDER BLOCK IN GROUNDING ELECTRODE CONDUCTOR. SEAL CONDUIT TO CONDUCTOR 100% WATERPROOF.2. GROUNDING ELECTRODE CONDUCTOR SHALL BE: A. MINIMUM SIZE 2/0 COPPER FOR 400A AND UNDER SERVICE B. SIZE 4/0 FOR OVER 400A SERVICE.5'-0"(TYP)10'-0"(TYP)TO SERVICE ENTRANCEEQUIPMENT GROUND BUS600V INSULATED COPPERCONDUCTOR INSTALLEDIN PVC RACEWAY#4/0 BARE COPPER GROUNDINGCONDUCTOR. INSTALL 1'-0" MIN.BELOW FINISHED GRADE (TYP.)3/4" ROUNDx10'-0" COPPERWELDGROUND ROD. DRIVE FULL LENGTHINTO GROUND. TOP OF THE ROD 12"MIN. BELOW FINISHED GRADE (TYP.)NL1L2 L3GROUNDEDCONDUCTORSERVICEENTRANCECONDUCTORSNEUTRAL BUSGROUND BUSSERVICE ENTRANCEDISCONNECTING MEANSPROVIDE ELECTRODE CONDUCTOR. PROVIDE INSULATED COPPERCONDUCTOR PER SPECIFICATIONS. IF NO SIZE SPECIFIED, PROVIDEINSULATED COPPER CONDUCTOR SIZED PER N.E.C. TABLE 250-66.INSTALL IN RIGID, SCHEDULE 40, PVC RACEWAY.METAL UNDERGROUND WATER PIPE IN DIRECT CONTACT WITHEARTH FOR 10 FEET OR MORE. SHALL BE SUPPLEMENTED BYITEMS 3 AND 4.BUILDING STRUCTURAL STEEL.MADE GROUNDING ELECTRODE. REFER TO "MADE GROUNDINGELECTRODE-GROUND GRID" DETAIL AND SPECIFICATIONS.MAIN BONDING CONDUCTOR. PROVIDE INSULATED COPPERCONDUCTOR SIZED PER N.E.C. ARTICLE 250-28.BOND GROUND BUS TO EQUIPMENT ENCLOSURE WITH BARECOPPER BONDING JUMPER SIZED PER N.E.C. ARTICLE 250-102.GROUNDING ELECTRODE SYSTEM:123456165MADE GROUNDING GRIDBUILDING STEELWATER SERVICE POINT OF ENTRANCE324MAIN BONDINGCONDUCTOREQUIPMENT BONDINGJUMPER 30"MINIMUM7 1/2"NOTES:PROVIDE BEADED STRAPS FOR SUPPORT OF CONDUITSON TOP RUNG OF EACH ASSEMBLY.PROVIDE REBAR SUPPORTS AS REQUIRED.PROVIDE CONDUIT SUPPORT REDUCERS AS REQUIREDFOR CONDUIT SIZE.ALL CONDUIT SHOWN SHALL BE SCHEDULE 80 PVC.SIZE AS SPECIFIED.PROVIDE PULL STRINGS IN CONDUITS1.2.3.4.5.FINISH GRADEPAVEMENT AS REQUIRED6" SCREENED TOP SOILFOR GRASS AREAS.6" WIDE, RED METALLIC (DETECTABLE)TAPE WITH WORDING:"CAUTION ELECTRIC LINE BURIED BELOW."BLACKBURN MANUFACTURING OR EQUAL.TAPE SHALL BE LOCATED 12" BELOWFINISHED GRADE.GRASS AREASPAVEMENT AREASBACKFILL WITH NATIVEMATERIAL IN 6" LIFTS.COMPACT AFTER EACHLIFT.BACKFILL WITH #2CRUSHED STONE IN 6"LIFTS. COMPACT AFTEREACH LIFT.3000 PSI CONCRETEAROUND ALLCONDUITSBASE SPACER AS SPECIFIED(TYPICAL)INTERMEDIATE SPACERCARLON CAT. NO.S289NJN(TYPICAL)GRASS AREASPAVEMENT AREASBACKFILL WITH NATIVEMATERIAL IN 6" LIFTS.COMPACT AFTER EACHLIFT.BACKFILL WITH #2CRUSHED STONE IN 6"LIFTS. COMPACT AFTEREACH LIFT.NOTES:PAVING OR TOPSOIL TOMATCH SITE CONDITIONSNO ROCKSOR DEBRISIN BACKFILL 30"MINIMUM3" SAND BEDAROUND CONDUITFINISHED GRADE1. READ THE SPECIFICATION 2610002. REPAIR ALL SETTLEMENT3. MINIMUM TOP SOIL-6".PROVIDE PULLSTRING IN EACHCONDUIT FOR FUTURE USE (TYPICAL)7 1/2"6" WIDE, RED METALLIC PLASTICCOATED DETECTABLE TAPE WITH WORDING"CAUTION BURIED ELECTRIC LINEBELOW." TAPE SHALL BE LOCATED12" BELOW FINISHED GRADE.PVC CONDUIT AS SPECIFIEDNOTES:NO ROCKSOR DEBRISIN BACKFILL 30"MINIMUM1. READ THE SPECIFICATIONS2. REPAIR ALL SETTLEMENT3. MINIMUM TOP SOIL- 6".6" WIDE, YELLOW DETECTABLE PLASTIC TAPE WITH WORDING "CAUTION BURIEDELECTRIC LINE BELOW." TAPE SHALL BE LOCATED 6" BELOW FINISHED GRADE.PAVING OR TOPSOIL TOMATCH SITE CONDITIONSFINISHED GRADEGRASS AREASBACKFILL WITH NATIVEMATERIAL IN 6" LIFTS.COMPACT AFTER EACH LIFT.PAVEMENT AREASBACKFILL WITH #2CRUSHED STONE IN 6"LIFTS. COMPACT AFTER EACH LIFT.PVC CONDUITAS SPECIFIED3" SAND BEDAROUND CONDUITPROVIDE PULLSTRING IN EACHCONDUIT FOR FUTURE USE (TYP)10"TOP VIEWSIDE VIEW4"PAD SHOULD BE A MINIMUM OF 6"LARGER THAN THE EQUIPMENTENCLOSURE ON ALL SIDES.#5@12" MAX.SPACINF ON CENTER EACH WAY, MID DEPTHPROVIDE 3/4", 45 DEGREECHAMFER ON ALL SIDES#5@12" MAX.SPACING ON CENTER EACH WAY, MID DEPTH82"83"12"8"8"25"12"15"NOTES1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO AC1-318.2.CONCRETE TO HAVE MINIMUM STRENGTH OF 5000PSI AFTER 28 DAYS. AIR ENTRAINMENT TO BE 6% +- 1%. ALL EXPOSED EDGES TO HAVE 3/4" CHAMFER.3. REINFORCING TO BE #5 - GRADE 60 BARS AND SHALL CONFORM TO ASTM A-615 OF LATEST DATE. REINFORCING TO BE PLACED A MINIMUM OF 2" CLEAR FROM FACE OF CONCRETE.4.ALL OPENING SHALL HAVE ADDITIONAL REBAR REINFORCEMENT OF 1- #5 EACH CORNER, MID DEPTH.5.LIFTING ANCHORS SHALL BE INSTALLED WITH APPROPRIATE DAYTON LIFTING ANCHORS OR EQUIVALENT12"4'-0" MIN.6"6"6"6"4'-0" MIN.2'-0"2'-0"6"PAVEMENT OR FINISHED GRADESUBGRADE3,000 PSICONCRETE (CLASS A)1/2" EXPANSION JOINTFILLER WITH SEALYELLOW POLYETHELENE COVER6" DIAMETER SCHEDULE 40 GALVANIZEDPIPE FILLED WITH 3,000 PSI CONCRETECONCRETE CAP-ROUND OFF TOP803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:03 PME501DETAILS02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1SWITCHGEAR ELEVATION2MADE GROUNDING ELECTRODE GROUND GRID3SERVICE ENTRANCE GROUNDING4DUCTBANK DETAIL (9 DUCT)5TYPICAL DIRECT BURIED CONDUIT DETAIL (3 DUCT)6TYPICAL DIRECT BURIED CONDUIT DETAIL7PAD DETAIL8PROTECTIVE BOLLARD DETAILREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 DCS120VWEATHER CAPFURNISHED BY E.C.INSTALLED BY M.C.CRITICAL MUFFLERFURNISHED BY E.C.ENGINE STARTCONTACTTO LOAD (REFER TOPOWER ONE-LINEDIAGRAM FOR FEEDERAND CIRCUIT BREAKERSIZE).ATS-SBAUTOMATIC TRANSFERSWITCH WITH BATTERYCHARGER, EXERCISERCLOCK, AND LOADSEQUENCER BY E.C.TO NORMAL POWER SOURCE(REFER TO POWER ONE-LINEDIAGRAM FOR FEEDER ANDCIRCUIT BREAKER SIZE).EMERGENCY BREAK GLASSSTATION BY E.C. INTERLOCKGAS VALVE AND GENERATORSHUTDOWNEXHAUST PIPINGBY M.C.VIBRATION ISOLATORS BY E.C.GENERATOR MAINCIRCUIT BREAKER BY E.C.STARTING BATTERIES BY E.C.ENGINECRANKCASE HEATERGENERATORBACK DRAFT DAMPERWITH BIRD SCREENAIR DISCHARGE DUCTFLEXIBLE DUCTCONNECTION250KW/313KVA DIESEL EMERGENCY GENERATOR208Y/120V, 3PH, 4WGENERATORPAD BY E.C. TOMANUFACTURERS REC.BY-PASS DAMPERGENERATOR CONTROLPANEL BY E.C.GENERATOR DISTRIBUTION PANELGENDP BY E.C.REMOTE GENERATOR CONTROL PANEL BY E.C.REFER TO MECHANICALPLANS FOR CHANGES.CSENGINE STARTCONTACTTO LOAD (REFER TOPOWER ONE-LINEDIAGRAM FOR FEEDERAND CIRCUIT BREAKERSIZE).ATS-EMAUTOMATIC TRANSFERSWITCH WITH BATTERYCHARGER, EXERCISERCLOCK, AND LOADSEQUENCER BY E.C.TO NORMAL POWER SOURCE(REFER TO POWER ONE-LINEDIAGRAM FOR FEEDER ANDCIRCUIT BREAKER SIZE).32 HOUR SUB-BASE FUEL TANKSOUND ATTENUATED WEATHERPROOF ENCLOSUREEXHAUST SCOOPW/ BIRD GUARD ANDDUCT DRAINNOTE:PITCH MUFFLER SLIGHTLYTO ENCOURAGE CONDENSATIONTO RUN AWAY FROM ENGINE.ALL EXHAUST PIPING INCLUDINGINSULATION SHALL BE BY FACTORYMOUNTED AND INSTALLED.1.2.MIN.MIN.8"6"NOTE: PITCH SLAB @ 1/8"/FT. AWAY FROM BUILDING.OVERALL PAD DIMENSIONS SHALL BE 15'-7"x5'-6".2'-0" 1'-0" 1'-0" 2'-0"(2) LAYERS OF 1" RIGID INSULATION(STAGGER JOINTS) TYP. UNDERSLAB12" CRUSHED STONE STUB BASECOMPACTED IN TWO LIFT. MIN.95%1" FILLET(1) #4 BAR @ PERIMETER(PROVIDE & INSTALLCORNER BARS)6" THICK 4000 PSI CONCRETE SLABW/6x6 #6 MESH MIDPOINT OF SLABPAVEMENT ON FIN. GRADE REPAIRTO MATCH EXIST. AFTER PAD ISCONSTRUCTED.CAST IRON LIDWITH SECURITY BOLTSGRADEGROUND RING#2 AWG, SOLID TINNED BARE COPPER WIRECLEAN SAND FILLPVC PIPE TO BE SLOTTEDAT BOTTOM STRADDLING GROUND RING30" MINIMUMNOTES:1. READ THE SPECIFICATIONS2. REPAIR ALL SETTLEMENT3. MINIMUM TOP SOIL-6".PAVING OR TOPSOIL TOMATCH SITE CONDITIONS5/8 " x 8'-0" COPPERGROUND ROD803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:05 PME502DETAILS02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1EMERGENCY GENERATOR SCHEMATIC2EMERGENCY GENERATOR PAD DETAIL3INSPECTION WELL DETAILREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 FINISHED FLOORCEILINGAAB12AAB134" MINIMUMPROVIDE 1 1/4" CONDUITINSIDE NEW WALL TURNEDUP INTO CEILING SPACEWITH PULL STRINGPROVIDE 4 11/16" SQUARE x 2 1/8" MINIMUMDEPTH BACKBOX WITH SINGLE GANG DEVICERING TO MATCH WALL THICKNESS AND TYPEPROVIDE SINGLE GANG BACKBOXWITH DOUBLE DUPLEXRECEPTACLE, FLUSH MOUNTEDPROVIDE 1/2" CONDUIT INSIDE NEW WALL TURNEDUP INTO CEILING SPACENOTE:ONLY APPLIES FOR SITUATIONS WHERE DEVICE IS LOCATED ON EXISTING BLOCK WALLSA.FINISHED FLOORCEILINGAAB12AAB134" MINIMUMPROVIDE 1 1/4" CONDUITINSIDE NEW WALL TURNEDUP INTO CEILING SPACEWITH PULL STRINGPROVIDE 4 11/16" SQUARE x 2 1/8" MINIMUMDEPTH BACKBOX WITH SINGLE GANG DEVICERING TO MATCH WALL THICKNESS AND TYPEPROVIDE 2-GANG BACKBOXWITH DOUBLE DUPLEXRECEPTACLE, FLUSH MOUNTEDPROVIDE 1/2" CONDUIT INSIDE NEW WALL TURNEDUP INTO CEILING SPACENOTE:ONLY APPLIES FOR SITUATIONS WHERE DEVICE IS LOCATED ON EXISTING BLOCK WALLSA.GENERAL NOTES:FLASH AND SEAL ROOF PENETRATIONAS REQUIRED TO MAINTAIN ANYROOF WARRENTEE. PROVIDE THESERVICES OF A QUALIFIED ROOFINGCONTRACTOR.GALVANIZED CONDUIT(SIZE AS REQUIRED)SEALTIGHTCONNECTORWEATHERPROOF DUPLEX RECEPTACLEWITH SPRING LOADED CAP. KEY LOCKABLE,WEATHER-PROOF ENCLOSURE SHALLBE MARKED "SUITABLE FOR WETLOCATIONS WHILE IN-USE."WPGFICONTROL OUTPUTCOMMON+24V dcPOWER PACKLINENEUTRAL277VCEILING MOUNTEDOCCUPANCY SENSORCONTROL OUTPUTCOMMON+24V dcCONTROL OUTPUTCOMMON+24V dcADDITIONAL CEILINGMOUNTED OCCUPANCY SENSORAS REQUIRED3-WAYSWITCH3-WAYSWITCHLOAD-aLOAD-bWALLSWITCHaWALLSWITCHbPROVIDE 3-WAY AND/ORDUAL LEVEL SWITCHING ASCALLED FOR ON PLANSADDITIONAL CEILINGMOUNTED OCCUPANCY SENSORAS REQUIREDNORMAL CIRCUITNORMAL CONTROLSNORMAL LIGHTING LOADUL 924ALCRNORMAL SWITCH SIGNALEMERGENCY LIGHTING LOADEMERGENCY ONNORMAL POWER ON/OFFNORMAL SENSING SIGNALEMERGENCY CIRCUITNORMAL CIRCUITUL 924ALCREMERGENCY LIGHTING LOADEMERGENCY POWER ONNORMAL SENSING SIGNALEMERGENCY CIRCUITCONTROLSTANDEM NORMAL/EMERGENCY SWITCHINGSEPARATELY SWITCHED EMERGENCYNOTE: EMERGENCY LIGHTING LOAD TO BE POWERED VIA EMERGENCY CIRCUIT AND CONTROLLED VIA SWITCHING SHOWN ON PLANS. UPON LOSS OF NORMAL SENSING SIGNAL ALCR SHALL BYPASS SWITCHING AND PROVIDE UNINTERRUPTED POWER TO EMERGENCY LOAD.NOTE: EMERGENCY LIGHTING LOAD TO BE POWERED VIA EMERGENCY CIRCUIT AND CONTROLLED VIA SWITCHING FROM LOCAL ROOM NORMAL LIGHTING CONTROLS/SWITCHING SHOWN ON PLANS. UPON LOSS OF NORMAL SENSING SIGNAL ALCR SHALL BYPASS SWITCHING AND PROVIDE UNINTERRUPTED POWER TO EMERGENCY LOAD.ELECTRIC STRIKECEILINGFLOOR6"MAGNET SWITCHMAGNETCARD READER - SINGLEGANG BOX FLUSHMOUNTED (UNSECURE SIDE)3/4 " CONDUIT TO SECURITY PANELPASSIVE INFRARED DETECTOR (REX) (SECURESIDE) (MOUNTED TO DOOR FRAME HEADER ORCEILING)8"x8"x4" JUNCTION BOX LOCATEON SECURE SIDE OF DOOR3/4 " CONDUITGENERAL NOTES:120VAC POWER REQUIRED AT SECURITYPANEL. EXACT LOCATION TO BE DETERMINED.ALL POWER AND CONDUIT TO BE SUPPLIEDAND INSTALLED BY ELECTRICAL CONTRACTOR.A.B.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:08 PME503DETAILS02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1TYPICAL NEW CONSTRUCTION FLUSH DATA OUTLET DETAIL2TYPICAL NEW CONSTRUCTION FLUSH DATA/QUAD OUTLET DETAIL3ROOF/EXTERIOR RECEPTACLE DETAIL4MULTIPLE OCCUPANCY SENSOR DETAIL5AUTOMATIC LOAD CONTROL RELAY WIRING DIAGRAM6DOOR SECURITY DETAILREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 FFFFFFFFSSHHFSDSDFSSHHSSHHFSDSDFSSHHSSFTSECSSHHFSDSDFSSHHSSHHFSDSDFSSHHSSFTSECSSHHFSDSDFSSHHSSHHFSDSDFSSHHSSFTSECFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFSSHHFSDSDFSSHHSSHHFSDSDFSSHHSSFTSECSSHHFSDSDFSSHHSSHHFSDSDFSSHHSFTSECSDSDNOTE:WIRING ON RISER DIAGRAM IS DIAGRAMMATIC ONLY AND ISNOT INTENDED TO INDICATE ROUTING OR QUANTITIES OFCABLES. PROVIDE WIRING FOR A COMPLETE AND WORKINGSYSTEM AS REQUIRED BY THE SYSTEM MANUFACTURER. ALLDEVICES MAY NOT BE INDICATED ON THE RISER DIAGRAM.REFER TO FLOOR PLANS FOR LOCATIONS AND EXACTQUANTITIES OF DEVICES.SDSDACACSDSDACACSDSDACACNOTES:NOTES:A.B.C.D.E.PROVIDE INITIATION DEVICE CIRCUITS AS REQUIRED TO CONNECTALL DEVICES.PROVIDE DUCT SMOKE DETECTORS AND FAN SHUTDOWN RELAYSAS CALLED FOR ON THE DRAWINGS.THIS DETAIL IS DIAGRAMMATIC ONLY: ALL QUANTITIES AND LOCATIONSOF DEVICES ARE SHOWN ON DRAWINGS.ALL SMOKE AND HEAT DETECTORS ARE CEILING MOUNTED UNLESSOTHERWISE NOTED.PROVIDE NOTIFICATION APPLIANCE CIRCUIT POWER EXTENDERPANELS AS REQUIRED. LOCATE IN FIELD TO OPTIMIZE NAC WIRING.PROVIDE 120 VOLT, 20A BRANCH CIRCUIT FROM NEAREST BRANCHCIRCUIT PANEL TO EACH PANEL.MAIN ENTRANCETWO TELEPHONE LINESTWO TELEPHONE LINES1ST FLOOR INITIATION DEVICE CIRCUITELEV.LOBBYSMOKEDAMPER(TYPICAL)2ND FLOOR INITIATION DEVICE CIRCUITELEV.LOBBYSMOKEDAMPER(TYPICAL)3RD FLOOR INITIATION DEVICE CIRCUITELEV.LOBBYSMOKEDAMPER(TYPICAL)FAN SHUTDOWN RELAYPRINTERDIGITALCOMMUNICATOR24 VDCFAN SHUTDOWN RELAY24 VDC120 VOLTCONNECTIONREMOTEANNUNCIATORDOOR HOLD OPEN CIRCUIT1ST FLOORNAC #1120VFACP(1ST FL)120V120V2ND FLOORNAC #13RD FLOORNAC #15TH FLOORNAC #14TH FLOORNAC #1SDSDACACAC5TH FLOOR INITIATION DEVICE CIRCUITELEV.LOBBYSMOKEDAMPER(TYPICAL)4TH FLOOR INITIATION DEVICE CIRCUITELEV.LOBBY120VMMSSSS SSHTCTCSHTO INITIATINGDEVICECIRCUIT (VIAZAM)THIS DRAWING IS DIAGRAMMATIC ONLY. FUNCTIONS SHOWN ASHARDWIRED MAY BE ACCOMPLISHED THROUGH THE USE OFINTELLIGENT DEVICES AND SOFTWARE.ALL RELAYS ARE SHOWN IN THE DE-ENERGIZED STATE.ELEVATORCAB LIGHTS,FANS ETC.1.2.NOTES:20A/1PINSTALL 208V AC, 30A DOUBLEPOLE, FUSIBLE, SINGLE THROW SWITCH (HUBBELL CATALOG NO 1392 OR APPROVED EQUIVALENT)SUPERVISINGRELAYR22ND FLOOR LOBBYSMOKE DETECTORAS NOTEDAS NOTEDaaINSTALL 208V AC FUSIBLE DISCONNECTSWITCH WITH AUXILARY CONTACTS. FUSESSIZED PER ELEVATOR MANUFACTURER'SRECOMMENDATIONSLOSSOF ACLOSSOF ACELEVATORCONTROLLER1ST FLOOR LOBBYSMOKE DETECTORRECALLRECALL3RD FLOOR LOBBYSMOKE DETECTORLOSS OF AC CONTACTS & SWITCHES ONLYREQUIRED IF ELEVATOR EQUIPED WITH BATTERYLOWERING.G.C. TO PROVIDE PROGRAMMING FOR ONLY (1) ELEVATOR TO OPERATE DURING GENERATOR USE. ATS CONNECTION TO ELEVATOR CONTROLLERS BY E.C.WIRING BY OTHERSWIRING BY E.C.1.OFF-TIME DELAY RELAYLEGEND:R1ELEVATOR SHAFT HEATDETECTORDESIGNER NOTES:ELEVATOR5TH FLOOR LOBBYSMOKE DETECTORELEVATOR SHAFTSMOKE DETECTORSH2.S4TH FLOOR LOBBYSMOKE DETECTORADDRESSABLE SMOKE DETECTOR WITH AIR DUCTHOUSING, INTAKE AND EXHAUST TUBING, AND REMOTEAUXILARY CONTACT.CLOSED POSITION INDICATORELECTRIC FUSE LINKOPEN POSITION INDICATORDAMPER ACTUATORTHIS DRAWING IS DIAGRAMMATICONLY. FUNCTIONS SHOWN ASHARDWIRED MAY BEACCOMPLISHED THROUGH THEUSE OF INTELLIGENT DEVICESAND SOFTWARE.NOTES:1.COMBINATION SMOKE/FIREDAMPER PACKAGE WITHELECTRIC ACTUATOR ANDSWITCH PACKAGE, FUNISHEDAND INSTALLED BY MECHANICALCONTRACTOR (TYP, 15 TOTAL)120VCIRCUIT20A/1P6#14 (2 SPARE),1/2"C (TYPTO EMS FOR DAMPER POSITIONBY CONTROLS CONTRACTORN6#14 (2 SPARE),1/2"C (TYPTO EMS FOR DAMPER POSITIONBY CONTROLS CONTRACTORBDA24VBATTERYBACKUP120V120VCONNECT TO FIRE ALARM PANEL5 SUPERVISORY MODULES REQUIRED:• BDA ANTENNA FAILURE• BDA TROUBLE• BDA POWER LOSS• BDA CHARGER TROUBLE• BDA LOW BATTERY(2) EMERGENCY CIRCUITSBDA STATUS ANNUNCIATOR.LOCATE ADJACENT TO FACP8-CONDUCTOR 18-24GA CABLELIGHTNING ARRESTOR, GROUNDED. LOCATED OUTSIDE, BEFORE THE CABLE BUILDING ENTRYANTENNA MAST TO BE BONDED TO BUILDING STEELDONOR ANTENNA.AIM TOWARDS PUBLIC SAFETY CITY REPEATERA2A3T1A11/2" PLENUM RATED COAXIAL CABLELEVEL 02LEVEL 03ROOFLEVEL 01GENERAL NOTES:1. PROVIDE A FULLY CODE COMPLIANT BI-DIRECTIONAL AMPLIFICATION SYSTEM AS REQUIRED PER IFC, IBC, NFPA AND ANY LOCAL CODES. CONFIRM WITH LOCAL AHJ TO DETERMINE REQUIRED FREQUENCIES AND VERIFY IF OTHER FIRST RESPONDER AGENCIES REQUIRE TWO-WAY RADIO ENHANCEMENTS. 2. A RADIO FREQUENCY SURVEY SHALL BE CONDUCTED TO DETERMINE THE SIGNAL STRENGTH WITHIN THE BUILDING. THE MINIMUM SIGNAL STRENGTH OF -95DBM SHALL BE MAINTAIN INTO AND OUT OF THE BUILDING TO DETERMINE COVERAGE AS REQUIRED PER IFC. 3. THE APPROPRIATE DONOR ANTENNA SHALL BE PROVIDED BASED ON REQUIRED FREQUENCY AND FACING IN THE DIRECTION OF THE CITY REPEATER. THE LOCATION OF THE ANTENNA SHALL BE COORDINATED WITH OTHER TRADES AND SHALL NOT INTERFERE WITH WORKING CLEARANCES OF EQUIPMENT OR PERSONNEL ACCESS WALKWAYS. 4. MAINTAIN ISOLATION BETWEEN THE DONOR ANTENNA AND DAS ANTENNAS WITHIN THE BUILDING. 5. A LIGHTNING ARRESTOR SHALL BE PROVIDED BY THE DONOR ANTENNA PRIOR TO ENTERING THE BUILDING. 6. THE BDA UNIT SHALL BE UNOBSTRUCTED BY OBJECTS IN FRONT OF THE UNIT. A BATTERY ENCLOSURE SHALL BE PROVIDED TO MAINTAIN A MINIMUM OF 24 HRS OF BATTERY BACKUP. 7. PROVIDE REQUIRED QUANTITY OF DAS ANTENNAS WITHIN THE BUILDING TO INSURE PROPER COVERAGE THROUGHOUT THE FLOOR. THE DAS ANTENNAS SHALL BE SUITED FOR THE REQUIRED FREQUENCY AND SHALL NOT EXCEED MANUFACTURES RECOMMENDED SPACING AND INSTALLATION. 8. ALL COAXIAL CABLING SHALL BE PLENUM RATED, COLOR CODED RED AND SHALL BE PROPERLY SECURED IN AN APPROPRIATE PATHWAY TO MAINTAIN PROPER BEND RADIUS AND PREVENT SAGGING OR KINKING. MAIN VERTICAL RUN OF COAXIAL CABLE SHALL BE IN A 2 HR RATED ENCLOSURE. THE RATING SHALL BE MAINTAINED IF THE MAIN RUN REQUIRES TO BE OFFSET WITHIN FLOORS. FINAL QUANTITY OF REQUIRED COAXIAL CABLE, SPLITTERS AND CONNECTORS SHALL BE DETERMINED BY FINAL DAS DESIGN AFTER CONDUCTING RF SURVEY. 9. PROVIDE A DEDICATED ANNUNCIATOR PANEL SEPARATE FROM THE FACP TO MONITOR THE STATUS OF THE BDA. FINAL LOCATION OF THE ANNUNCIATOR PANEL SHALL BE DETERMINED BY THE LOCAL AHJ. 10. THE BDA SHALL BE FULLY SUPERVISED BY THE FACP VIA ADDRESSABLE MONITORING MODULES TO IDENTIFIED THE FOLLOWING CONDITIONS; DONOR ANTENNA MALFUNCTION, BDA FAILURE, LOW BATTERY CAPACITY, LOSS OF NORMAL AC POWER AND FAILURE OF A BATTERY CHARGER.11. THE BDA SHALL SUPPORT FREQUENCIES OF 806-824 Mhz AND 769-799 Mhz PER THE CITY OF ITHACA. CONTACT LEE SHURTLEFF, DIRECTOR OF THE COUNTY DEPARTMENT OF EMERGENCY RESPONSE, FOR FURTHER REQUIREMENTS.LEVEL 04LEVEL 05806-824 MHz769-799 MHzAND803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:11 PME504DETAILS02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1FIRE ALARM RISER DIAGRAM2FIRE ALARM ELEVATOR CONTROL WIRING DIAGRAM3FIRE/SMOKE DAMPER WIRING DIAGRAM4BDA RISER DIAGRAMREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 AA34B24A34B1System No. C-AJ-1292March 5, 2007F Rating - 3 HrT Rating - 0 HrL Rating At Ambient - Less Than 1 CFM/sq ftL Rating At 400 F - 2 CFM/sq ftW Rating - Class ISECTION A-AAA1. Floor or Wall Assembly- Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3)concrete. Wall may also be constructed of any UL ClassifiedConcrete Blocks*. Max diam of opening is 6 in. (152 mm).SeeConcrete Blocks(CAZT) category in the Fire Resistance Directory for names of manufacturers.2. Sleeves- (Optional) - The following sleeves may be used:A. Metallic Sleeve- Nom 6 in. (152 mm) diam (or smaller) steel Schedule 40 (or heavier) pipe cast or grouted into floor or wall assembly, flush with floor or wall surfaces. As an alternate, nom 6 in. (152mm) diam (or smaller) sleeve fabricated from nom 0.019 in. (0.48 mm) thick galv steel cast or grouted into floor or wall assembly flush with floor or wall surfaces.B. Nonmetallic Sleeve- Nom 6 in. (152 mm) diam (or smaller) Schedule 40 polyvinyl chloride (PVC) pipe cast or grouted into floor or wall assembly, flush with floor or wall surfaces.3. Through Penetrants- One metallic pipe, conduit or tubing installed either concentrically or eccentrically within the firestop system.The annular space shall be min 1/2 in. (13 mm) to max 2-3/8 in. (60 mm) Pipe, conduit or tubing to be rigidly supported on both sides offloor or wall assembly. The following types of pipe, conduit or tubing may be used: A.Steel Pipe- Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B.Conduit- Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or steel conduit. C.Copper Tubing- Nom 3 in. (76 mm) diam (or smaller) Type M (or heavier) copper tubing. D.Iron Pipe- Nom 4 in. (102 mm) diam (or smaller) cast or ductile iron pipe.4. Firestop System- The firestop system shall consist of the following:A. Packing Material- Min 3-3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form so that the width of the wool is compressed at least 50 percent. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material.B. Fill,Void or Cavity Material* - Sealant- Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor or with both surfaces of wall.3M COMPANY- FB-1000 NS, FB-1003SL or FB-3000 WT*Bearing the UL Classification MarkSECTION A-A5232341System No. C-AJ-3030March 05, 2007F Ratings - 1-1/2, 2 and 3 Hr (See Item 5)T Rating - 0 HrL Rating At Ambient - 129 CFM/sq ftL Rating At 400 F - 92 CFM/sq ft1. Floor or Wall Assembly- Min 2-1/2 in. (64 mm) thick lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructedof any UL ClassifiedConcrete Blocks*. Max diam of opening is 8 in. (203 mm).SeeConcrete Blocks(CAZT) category in the Fire Resistance Directory for names of manufacturers.2. Sleeve(Optional) - Nom 8 in. (203 mm) diam (or smaller) Schedule 40 (or heavier) steel pipe or nom 6 in. (152 mm) diam (or smaller) Schedule 40 polyvinylchloride (PVC) pipe cast into floor or wall assembly. Sleeve to be flush with or project max 2 in. (51 mm) from top surface of floor or both surfaces of wall. When PVCsleeve is used, max cable conductor size is No. 12 AWG. As an alternate, nom 8 in. (203 mm) diam (or smaller) sleeve fabricated from nom 0.019 in. (0.48 mm) thickgalv steel cast or grouted into floor or wall assembly flush with floor or wall surfaces.3. Cables- Aggregate cross-sectional area of cables to be min 10 percent to max 40 percent of the cross-sectional area of the opening. Cables to be rigidly supportedon both sides of the floor or wall assembly. Any combination of the following types and sizes of cables may be used: A. Max 1000 kcmil single-conductor copper or aluminum power cable; cross-linked polyethylene insulation. B. Max No. 2/0 AWG multiconductor copper or aluminum power cables; cross-linked polyethylene, polyvinyl chloride, neoprene rubber, hypalon or silicone rubberinsulation and jacket materials. C. Max No. 12 AWG multiconductor copper control cables; cross-linked polyethylene, polyvinyl chloride, neoprene rubber, hypalon or silicone rubber insulation andjacket materials. D. Max 400 pair No. 24 AWG copper telephone cables; polyvinyl chloride insulation and jacket materials. E. Multiple fiber optical communication cable jacketed with PVC and having a max outside diam of 5/8 in. F. Max 200 pair No. 22 AWG (or smaller) copper conductor with polyvinyl chloride (PVC) insulation and jacketing material. G. Max 3/C No. 3/0 AWG (or smaller) copper or aluminum conductor SER cables with PVC insulation and jacket. H. Max 3/C No. 2/0 AWG (or smaller) copper conductor PVC jacketed aluminum clad or steel clad TECK 90 cable. I. Max 3/C with ground No. 8 AWG (or smaller) copper conductor NM cable with PVC insulation and jacket. J. RG/U coaxial cable with fluorinated ethylene (FE) or PVC insulation and jacket. K. Max 4 pair No. 24 AWG (or smaller) copper conductor data cable with Hylar jacket and insulation. L. Max 3/C No. 12 AWG (or smaller) MC (BX) copper cable with polyvinyl chloride insulation and jacket materials. M. Through Penetrating Product* - Any cables, Armored Cable+ or Metal Clad Cable+ currently Classified under the Through Penetrating Product category. SeeThrough Penetrating Product (XHLY) category in the Fire Resistance Directory for names of manufacturers4. Packing Material- Min 1 in. (25 mm) thickness of 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. Packingmaterial to be recessed from top surface of floor or sleeve or from both surfaces of wall or ends of sleeve as required to accommodate the required thickness of fillmaterial (Item 5).5. Fill,Void or Cavity Material* - Caulk or Sealant- Applied to fill the through opening to a min thickness of 1 in. (25mm) flush with the top surface of thefloor or sleeve or both surfaces of wall or ends of sleeve. Caulk or sealant to be forced into interstices of cable group to max extent possible.F Rating of firestop systems is dependent upon the through opening size, the thickness of the concrete, the sleeve type and percentcable fill, as tabulated below:3M COMPANY- CP 25WB+ caulk or FB-3000 WT sealant.*Bearing the UL Classification MarkingMax ThroughOpening Diam, in.(mm)Min ConcreteThkns in. (mm)SleeveType% CableFillF RatingHr6 (152)2-1/2 (64)PVC15-4026 (152) 2-1/2 (64) PVC 10-15 36 (152)4-1/2 (114) PVC 10-40 36 (152) 4-1/2 (114)None 10-40 36 (152) 4-1/2 (114)Steel 10-40 38 (203) 2-1/2 (64) None 15-401-1/28 (203) 4-1/2 (114) None 15-33 28 (203)2-1/2 (64) None 10-15 38 (203)2-1/2 (64) Steel 15-40 1-1/28 (203)2-1/2 (64) Steel 10-15 38 (203) 4-1/2 (114) Steel 10-22 3SECTION A-A2321B31AAA1. Wall Assembly- The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the mannerdescribed in the individual U300, U400 or V400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include thefollowing construction features:A. Studs- Wall framing may consist of either wood studs or steel channel studs. Wood studs toconsist of nom 2 in. by 4 in. (51 mm by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studsto be min 3-1/2 in. wide (89 mm) spaced max 24 in. (610 mm) OC.B. Gypsum Board*- The gypsum board type, thickness, number of layers, fastener type and sheetorientation shall be as specified in the individual U300 or U400 Series Design in the UL FireResistance Directory. Max diam of opening is 3-1/2 in. (89 mm).The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it isinstalled.2. Through Penetrants- One nonmetallic pipe or conduit installed eccentrically or concentrically within opening. Annular spacebetween penetrant and periphery of opening to be min 0 in. (point contact) to max 1-1/8 in. (0 mm to max 29 mm). Penetrant to be rigidlysupported on both sides of wall. The following types and sizes of penetrants may be used:A. Polyvinyl Chloride (PVC) Pipe- Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid core orcellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) pipingsystem.B. Chlorinated Polyvinyl Chloride (CPVC) Pipe- Nom 2 in. (51 mm) diam (or smaller) SDR13.5 CPVCpipe for use in closed (process or supply) piping systems.C. Rigid Nonmetallic Conduit+- Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduitinstalled in accordance with Article 347 of the National Electrical Code (NFPA No. 70).D. Acrylonitrile Butadiene Styrene (ABS) Pipe- Nom 1-1/2 in. (38 mm) diam (or smaller) Schedule 40solid core or cellular core ABS pipe for use in closed (process or supply) or vented (drain, waste orvent) piping systems.E. Electrical Nonmetallic Tubing (ENT)+- Nom 1-1/4 in (32 mm) diam (or smaller) ENT installed inaccordance with Article 331 of the National Electrical Code (NFPA No. 70). SeeElectrical Nonmetallic Tubing(FKHU) category in the Electrical Construction Materials Directory for names of manufacturers.3. Fill,Void or Cavity Material* - Caulk or Sealant- Min 5/8 in. (16 mm) thickness of caulk applied within annulus, flush withboth surfaces of wall. Min 1/4 in. (6 mm) diam bead of caulk applied to gypsum board/penetrant interface at point contact location on bothsides of wall.3M COMPANY- IC 15WB+, CP 25WB+ caulk or FB-3000 WT sealant(Note: CP 25WB+ not suitable for use with CPVC pipes.)*Bearing the UL Classification Marking+Bearing the UL Listing MarkSystem No.W-L-2299May 19, 2005F Ratings - 1 & 2 Hr (See Item 1)T Rating - 0 HrSystem No.W-L-1001June 15, 2005F Ratings - 1, 2, 3 and 4 Hr (See Items 2 and 3)T Ratings - 0, 1, 2, 3, and 4 Hr (See Item 3)L Rating At Ambient - less than 1 CFM/sq ftL Rating At 400 F - less than 1 CFM/sq ft1. Wall Assembly- The 1, 2, 3 or 4 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in themanner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include thefollowing construction features:A. Studs- Wall framing may consist of either wood studs (max 2 hr fire rated assemblies) or steel channel studs. Wood studs toconsistof nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC with nom 2 by 4 in. (51 by 102 mm) lumber endplates andcross braces. Steel studs to be min 3-5/8 in. (92 mm) wide by 1-3/8 in. (35 mm) deep channels spaced max 24 in.(610 mm) OC.B. Gypsum Board*- Nom 1/2 or 5/8 in. (13 or 16 mm) thick, 4 ft. (122 cm) wide with square or tapered edges. The gypsum wallboardtype, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Designin the UL Fire Resistance Directory. Max diam of opening is 26 in. (660 mm).2. Through Penetrant- One metallic pipe, conduit or tubing installed either concentrically or eccentrically within the firestop system. Theannular space between pipe, conduit or tubing and periphery of opening shall be min of 0 in. (0 mm) (point contact) to max 2 in. (51 mm).Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits ortubing may be used:A. Steel Pipe- Nom 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.B. Iron Pipe- Nom 24 in. (610 mm) diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in. (305 mm) diam (orsmaller) or Class 50 (or heavier) ductile iron pressure pipC. Conduit- Nom 6 in. (152 mm) diam (or smaller) steel conduit or nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubingD. Copper Tubing- Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubingE. Copper Pipe- Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe.F. Through Penetrating Product* - Flexible Metal Piping- The following types of steel flexible metal gas piping may be used:1. Nom 2 in. (51 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed onboth sides offloor or wall assembly. OMEGA FLEX INC2. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed onboth sides offloor or wall assembly. GASTITE, DIV OF TITEFLEX3. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed onboth sides offloor or wall assembly. WARD MFG INC3. Fill,Void or Cavity Material* - Caulk or Sealant- Min 5/8. 1-1/4,1-7/8 and 2-1/2 in. (16, 32, 48 and 64 mm) thickness of caulk for1, 2, 3 and 4 hr rated assemblies, respectively, applied within annulus, flush with both surfaces of wall. Min 1/4 in. (6 mm) diam bead of caulkapplied to gypsum board/penetrant interface at point contact location on both sides of wall.The hourly F Rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in thefollowing table.The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assemblyin which it is installed, as tabulated below:+When copper pipe is used, T Rating is 0 hr.3M COMPANY- CP 25WB+ caulk or FB-3000 WT sealant,*Bearing the UL Classification MarkingMax Pipe or Conduit Diam in. (mm)F Rating HrT Rating Hr1 (25)1 or 20+, 1 or 21 (25)3 or 43 or 44 (102)1 or 206 (152)3 or 4012 (305)1 or 20SECTION A-A3231A1BAASECTION A-A423421A1BAASystem No.W-L-3195October 01, 2008F Ratings - 1 and 2 Hr (See Item 1)T Ratings - 0 and 1/2 Hr (See Item 1)1. Wall Assembly- The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the mannerdescribed in the individual U300, U400 or V400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include thefollowing construction features:A. Studs- Wall framing may consist of either wood studs or steel channel studs. Wood studs toconsist of nom 2 by 4 in. (51 mmby 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs tobe min 3-1/2 in. (89 mm) wide spaced max 24 in. (610 mm) OC.B. Gypsum Board*- The gypsum board type, thickness, number of layers, fastener type and sheetorientation shall be asspecified in the individual Design in the UL Fire Resistance Directory. Max diamof opening is 5 in. (127 mm).The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it isinstalled. The hourly T Rating is 0 and 1/2 Hr for 1 and 2 Hr rated assemblies, respectively.2. Steel Sleeve(Optional) - Cylindrical sleeve fabricated from min 0.018 in. (0.46 mm) thick (No. 28 gauge) galv sheet steel and having amin 1 in. (25 mm) lap along the longitudinal seam. Length of sleeve to be equal to or max 2 in. (51 mm) greater than the thickness of wall.Ends of sleeve to be flush with or extend a max 1 in. (25 mm) beyond each surface of wall.3. Cables- Max 4 in. (102 mm) diam cable bundle installed eccentrically or concentrically within opening. Annular space between cablebundle and periphery of opening or sleeve to be min 0 in. (0 mm, point contact) to max 1 in. (25 mm). Cable bundle to be rigidly supported onboth sides of wall. The following types and sizes of cables may be used: A. Max 200 pair No. 22 AWG (or smaller) copper conductor with polyvinyl chloride (PVC) insulation andjacketing material. B. Max 1/C No. 350 kcmil (or smaller) copper conductor cable with cross-linked polyethylene (XLPE) orPVC jacket. C. Max 7/C No. 12 AWG (or smaller) copper conductor power and control cables with XLPE or PVCinsulation with XLPE or PVCjacket. D. Max 3/C No. 4/0 AWG (or smaller) copper or aluminum conductor SER cables with XLPE or PVCinsulation and jacket. E. Max 4/C No. 2/0 AWG (or smaller) copper conductor, aluminum clad or steel clad TECK 90 cable withor without PVC jacketed. F. Max 110/125 fiber optic (F.O.) cable with PVC insulation and jacket. G. Max 3/C with ground No. 8 AWG (or smaller) copper conductor NM cable with PVC insulation andjacket. H. Max RG/U coaxial cable with fluorinated ethylene insulation and jacket. I. Max 4 pair No. 24 AWG (or smaller) copper conductor data cable with Hylar jacket and insulation. J.Through Penetrating Product*- Any cables,Armored Cable+orMetal Clad Cable+currently Classifiedunder theThrough Penetrating Productcategory.SeeThrough Penetrating Product(XHLY) category in the Fire Resistance Directory for names ofmanufacturers.4. Fill,Void or Cavity Material* - Caulk or Sealant- Min 5/8 in. (16 mm) thickness of caulk applied within annulus, flush withboth surfaces of wall. Min 1/4 in. (6 mm) diam bead of caulk applied to gypsum board/cable bundle interface at point contact location on bothsides of wall.3M COMPANY- IC 15WB+, CP 25WB+ caulk or FB-3000 WT sealant*Bearing the UL Classification MarkingTHERE ARE MULTIPLE FIRE PENETRATION ASSEMBLIESFOR ANY GIVEN PENETRATION. OTHER PENETRATIONASSEMBLIES SHALL BE ACCEPTABLE BASED ON PRIORAPPROVAL ONLY.2AA3C3A3A3B3C211. Floor or Wall Assembly- Min 2-1/2 in. (64 mm) thick lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3)concrete. Wall may also be constructed of any UL ClassifiedConcrete Blocks*. Max diam of circular opening is 6-1/2 in. (165mm).SeeConcrete Blocks(CAZT) category in the Fire Resistance Directory for names of manufacturers.2. Nonmetallic Pipe or Conduit - Nom 4 in. (102 mm) diam (or smaller) Schedule 40 solid core or cellular core, polyvinylchloride (PVC) pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems orRigid NonmetallicConduit++ or SDR 13.5 chlorinated polyvinyl chloride (CPVC) pipe for use in closed (process or supply) piping systems. A maxof one pipe or conduit is permitted in the firestop system. Except as noted in Item B, the pipe or conduit shall be centered in thethrough opening. Pipe or conduit to be rigidly supported on both sides of floor or wall assembly.SeeRigid Nonmetallic Conduit(DZKT) category in the UL Electrical Construction Materials Directory for names ofmanufacturers.3. Firestop System- The hourly T Ratings for the firestop system are dependent upon the firestop orientation (wall or floor),the size of the nonmetallic pipe or conduit, and the floor thickness, as tabulated below: (a) W = wall, F = floor (b) Min concrete floor thickness is 2-1/2 in. (64 mm).The details of the firestop system shall be as follows:A. Steel Support Clips- Nom 1 in. (25 mm) wide by nom 0.019 in. (0.5 mm) thick (28 gauge) galv steel strips field-formedinto "Z"-shape with height of Z-shape equal to the floor thickness and with width of bottom (as installed) leg of sufficient length tospan annular space. Top (as installed) leg of Z-shape to be min 2 in. (51 mm) long and may or may not be secured to top surfaceof floor with masonry anchors. As an alternate to the Z-shape clips, the galv steel strips may be formed into "L" shape with heightequal to 2 in. (51 mm) and with bottom (as installed) leg of sufficient length to span annular space. Clips secured to outermostwrap strip layer with steel wire tie prior to insertion in through opening. Min of three steel support clips to be used, symmetricallylocated, with bottom leg of clips flush with bottom plane of floor. When annular space around nom 1/2 in. to 2 in. (13 mm to 51 mm)diam pipe in floor assembly is 1/4 in. to 3/8 in. (6 mm to 10 mm) , steel support clips are not required.B. Fill,Void or Cavity Materials* - Wrap Strip- Nom 1/4 in. (6 mm) thick intumescent elastomeric material faced onone side with aluminum foil, supplied in 2 in. (51 mm) wide strips. Nom 2 in. (51 mm) wide strips tightly wrapped aroundnonmetallic pipe (foil side exposed) to fill annular space around pipe. A min of one layer of wrap strip is required for nom 1/2 in. to2 in. (13 mm to 51 mm) diam pipes. A min of two layers of wrap strip is required for nom 2-1/2 in. and 3 in. (64 mm and 76 mm)diam pipes. A min of three layers of wrap strip is required for nom 3-1/2 in. and 4 in. (89 mm and102 mm) diam pipes. Each layerof wrap strip to be installed with butted seam with butted seams in successive layers staggered. Wrap strip layers securely boundwith steel wire or aluminum foil tape and slid into through opening such that the bottom edges are flush with the bottom plane ofthe floor and are resting on the steel support clip legs. When nom 2 in. to 4 in. (51mm to 102 mm) diam PVC pipe is used in min4-1/2 in. (114 mm) thick concrete floor, the pipe may be installed eccentrically in the through opening (min zero clearance at pointcontact location) provided that (1) the inside diam of the through opening is 1.3 to 1.5 times larger than the outside diam of thepipe, (2) the annular space between the pipe and the sides of the opening at the bottom 2 in. (51 mm) of the through opening iscompletely filled with wrap strip layers installed following the contour of the pipe and (3) the bottom edges of the wrap strip layersare reliably supported by "Z"-shaped steel support clips anchored to the top surface of the concrete floor. In wall assemblies, thewrap strip layers on the nonmetallic pipe are to be installed in the same manner used for floor assemblies, but shall be installedsymmetrically on both sides of the wall with the exposed edges of the wrap strip layers flush with the wall surfaces.3M COMPANY- FS-195+C. Fill,Void or Cavity Materials* - Caulk or Sealant- Min 1/4 in. (6 mm) diam continuous bead applied to insidewalls of through opening prior to installation of steel support clips and/or wrap strip. Caulk bead to be recessed 1 in. (25 mm) fromthe bottom plane or floor. In wall assemblies, caulk bead to be recessed 1 in. (25 mm) from wall surface on both sides of wall. Infloor assemblies, a nom 1/2 in. (13 mm) thick coating of caulk is to be applied to the top edges of the wrap strip layers and to fill allgaps at the wrap strip/concrete interface. In wall assemblies, the exposed edges of the wrap strip layers and all gaps at the wrapstrip/concrete interface on both sides of the wall to be coated with thin layer of caulk.3M COMPANY- CP 25WB+, IC 15WB caulk or FB-3000 WT sealant.(The W Rating applies only when FB-3000WT sealant is used.)*Bearing the UL Classification Marking++Bearing UL Listing MarkOrientation (a)Nom Pipe Diam in.(mm)Annular Space in.(mm)F Rating Hr T Rating HrF (b)1/2 to 2 (13 to 51) 1/4 to 1 (6 to 25)20F (b)2-1/2, 3 (64, 76) 1/2 to 1 (13 to 25)20W, F 1/2 to 2 (13 to 51)1/2 to 1 (6 to 25) 2 2W, F 2-1/2, 3 (64, 76) 1/2 to 1 (13 to 25) 2 2W, F 3-1/2, 4 (89, 102) 3/4 to 1 (19 to 25) 2 2System No. C-AJ-2002May 18, 2005F Rating - 2 HrT Ratings - 0 and 2 HrL Rating at Ambient - 7 CFM/sq ftL Rating at 400 F - less than 1 CFM/sq ft (See Item 3C)W Rating - Class I (See Item 3)SECTION A-A803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:16 PME505DETAILS02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1CONDUIT PENETRATION ASSEMBLIESREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 L1, L2, L3 38.1A 3phL1, L2 0.1A 1phL1, L2 1.4A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 1.4A 1phL1, L2 0.8A 1phOUT F1,F2to centralized controllerIN F1,F2OUT F1,F2OUT F1,F2OUT F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2ACCU-1WREYQ72XATJAREYQ72XATJABS 3BSQ36TVJADFC-15BFXSQ15TAVJUBRC1E73BS 2BSQ36TVJADFC-09BFXSQ09TAVJUBRC1E73BS 1BS4Q54TVJABCDDFC-07BFXSQ07TAVJUBRC1E73DFC-07AFXSQ07TAVJUBRC1E73DFC-15AFXSQ15TAVJUBRC1E73DFC-05BKFXSQ05TAVJUBRC1E73L1, L2, L3 38.1A 3phL1, L2 0.6A 1phL1, L2 0.8A 1phL1, L2 1.8A 1phL1, L2 1.8A 1phL1, L2 1.8A 1phL1, L2 0.8A 1phOUT F1,F2to centralized controllerIN F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2ACCU-1NREYQ96XATJAREYQ96XATJABS 4BS6Q54TVJABCDEFDFC-12AFXSQ12TAVJUBRC1E73DFC-24AFXSQ24TAVJUBRC1E73DCF-24BFXSQ24TAVJUBRC1E73DFC-30AFXSQ30TAVJUBRC1E73DFC-09RFXSQ09TAVJUBRC1E73L1, L2, L3 38.1A 3phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 1.4A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 1.4A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phOUT F1,F2to centralized controllerIN F1,F2OUT F1,F2OUT F1,F2OUT F1,F2OUT F1,F2OUT F1,F2OUT F1,F2OUT F1,F2OUT F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2ACCU-1EREYQ96XATJAREYQ96XATJABS 5BSQ36TVJADFC-05BFXSQ05TAVJUBRC1E73BS 6BSQ36TVJADFC-05CFXSQ05TAVJUBRC1E73BS 7BSQ36TVJADFC-12RFXSQ12TAVJUBRC1E73BS 8BSQ36TVJADFC-05AFXSQ05TAVJUBRC1E73BS 9BSQ36TVJADFC-15EFXSQ15TAVJUBRC1E73BS 10BSQ36TVJADFC-07DFXSQ07TAVJUBRC1E73BS 11BSQ36TVJADFC-15DFXSQ15TAVJUBRC1E73BS 12BSQ36TVJADFC-12BFXSQ12TAVJUBRC1E73L1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.4A 1phL1, L2 1.6A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phOUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2ACCU-1SREYQ72XATJAREYQ72XATJABS 13BS4Q54TVJABCDDFC-05GFXSQ05TAVJUBRC1E73DFC-05HFXSQ05TAVJUBRC1E73BS 14BS4Q54TVJABCDDFC-18AFXSQ18TAVJUBRC1E73DFC-05FFXSQ05TAVJUBRC1E73DFC-05DFXSQ05TAVJUBRC1E73DFC-09SFXSQ09TAVJUBRC1E73803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:18 PME506DETAILS02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 L1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 1.8A 1phL1, L2 0.4A 1phL1, L2 2.5A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 1.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.6A 1phL1, L2 1.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 1.8A 1phL1, L2 1.6A 1phL1, L2 1.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 1.4A 1phL1, L2 0.8A 1phL1, L2 1.4A 1phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 1.6A 1phL1, L2 1.4A 1phL1, L2 0.8A 1phOUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2ACCU-2SREYQ96XATJAREYQ96XATJABS 15BS4Q54TVJABCDDFC-24FFXSQ24TAVJUBRC1E73BS 16BS4Q54TVJABCDDFC-36AFXSQ36TAVJUBRC1E73BS 17BSQ60TVJADFC-09HFXSQ09TAVJUBRC1E73DFC-09GFXSQ09TAVJUBRC1E73DFC-12DFXSQ12TAVJUBRC1E73DFC-24DFXSQ24TAVJUBRC1E73ACCU-2EREYQ72XATJAREYQ72XATJABS 21BS6Q54TVJABCDEFDFC-15HFXSQ15TAVJUBRC1E73DFC-05NFXSQ05TAVJUBRC1E73DFC-09FFXSQ09TAVJUBRC1E73DFC-09EFXSQ09TAVJUBRC1E73DFC-05LFXSQ05TAVJUBRC1E73DFC-05MFXSQ05TAVJUBRC1E73BS 22BSQ36TVJADFC-12EFXSQ12TAVJUBRC1E73ACCU-2NREYQ72XATJAREYQ72XATJABS 20BS4Q54TVJABCDDFC-24CFXSQ24TAVJUBRC1E73DFC-18CFXSQ18TAVJUBRC1E73DFC-30CFXSQ30TAVJUBRC1E73ACCU-2WREYQ96XATJAREYQ96XATJABS 19BS4Q54TVJABCDDFC-15NFXSQ15TAVJUBRC1E73DFC-05KFXSQ05TAVJUBRC1E73DFC-15GFXSQ15TAVJUBRC1E73BS 18BS4Q54TVJABCDDFC-07OFXSQ07TAVJUBRC1E73DFC-18BFXSQ18TAVJUBRC1E73DFC-15MFXSQ15TAVJUBRC1E73DFC-05JFXSQ05TAVJUBRC1E73803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:20 PME507DETAILS02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 L1, L2, L3 38.1A 3phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.6A 1phL1, L2 0.8A 1phL1, L2 1.6A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 1.6A 1phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 1.6A 1phL1, L2 1.6A 1phL1, L2 2.5A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 1.4A 1phL1, L2 0.8A 1phOUT F1,F2to centralized controllerIN F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2ACCU-3EREYQ72XATJAREYQ72XATJABS 28BS8Q54TVJABCDEFGHDFC-05BDFXSQ05TAVJUBRC1E73DFC-05BEFXSQ05TAVJUBRC1E73DFC-05BFFXSQ05TAVJUBRC1E73DFC-05BCFXSQ05TAVJUBRC1E73DFC-09OFXSQ09TAVJUBRC1E73DFC-05BAFXSQ05TAVJUBRC1E73DFC-05BBFXSQ05TAVJUBRC1E73DFC-12QFXSQ12TAVJUBRC1E73ACCU-3WREYQ72XATJAREYQ72XATJABS 23BS4Q54TVJABCDDFC-12PFXSQ12TAVJUBRC1E73DFC-05AUFXSQ05TAVJUBRC1E73DFC-05AVFXSQ05TAVJUBRC1E73BS 24BS6Q54TVJABCDEFDFC-05ATFXSQ05TAVJUBRC1E73DFC-18JFXSQ18TAVJUBRC1E73DFC-05AWFXSQ05TAVJUBRC1E73DFC-05ASFXSQ05TAVJUBRC1E73DFC-05ARFXSQ05TAVJUBRC1E73DFC-07LFXSQ07TAVJUBRC1E73ACCU-3SREYQ72XATJAREYQ72XATJABS 29BS4Q54TVJABCDDFC-05BJFXSQ05TAVJUBRC1E73DFC-07MFXSQ07TAVJUBRC1E73DFC-09PFXSQ09TAVJUBRC1E73DFC-18IFXSQ18TAVJUBRC1E73BS 30BS4Q54TVJABCDDFC-09QFXSQ09TAVJUBRC1E73DFC-05BIFXSQ05TAVJUBRC1E73DFC-05BHFXSQ05TAVJUBRC1E73DFC-05BGFXSQ05TAVJUBRC1E73ACCU-3NREYQ96XATJAREYQ96XATJABS 25BS4Q54TVJABCDDFC-18KFXSQ18TAVJUBRC1E73DFC-18LFXSQ18TAVJUBRC1E73DFC-36CFXSQ36TAVJUBRC1E73BS 26BSQ36TVJADFC-05AZFXSQ05TAVJUBRC1E73BS 27BSQ36TVJADFC-05AYFXSQ05TAVJUBRC1E73DFC-15OFXSQ15TAVJUBRC1E73DFC-05AXFXSQ05TAVJUBRC1E73803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:22 PME508DETAILS02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 L1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 1.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.4A 1phL1, L2 1.4A 1phL1, L2 1.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.1A 1phL1, L2 1.4A 1phL1, L2 0.1A 1phL1, L2 1.6A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.4A 1phL1, L2 1.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phOUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2OUT F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2OUT F1,F2IN F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2OUT F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2ACCU-4WREYQ96XATJAREYQ96XATJABS 31BS4Q54TVJABCDDFC-30BFXSQ30TAVJUBRC1E73DFC-07EFXSQ07TAVJUBRC1E73DFC-09IFXSQ09TAVJUBRC1E73DFC-05OFXSQ05TAVJUBRC1E73BS 32BS4Q54TVJABCDDFC-15JFXSQ15TAVJUBRC1E73DFC-15IFXSQ15TAVJUBRC1E73DFC-05PFXSQ05TAVJUBRC1E73DFC-05AOFXSQ05TAVJUBRC1E73ACCU-4SREYQ96XATJAREYQ96XATJABS 41BSQ36TVJADFC-05XFXSQ05TAVJUBRC1E73BS 42BSQ36TVJADFC-07PFXSQ07TAVJUBRC1E73BS 39BS4Q54TVJABCDDFC-07NFXSQ07TAVJUBRC1E73DFC-07IFXSQ07TAVJUBRC1E73DFC-07PFXSQ07TAVJUBRC1E73DFC-12JFXSQ12TAVJUBRC1E73BS 40BS4Q54TVJABCDDFC-12KFXSQ12TAVJUBRC1E73DFC-12LFXSQ12TAVJUBRC1E73DFC-12SFXSQ12TAVJUBRC1E73DFC-05UFXSQ05TAVJUBRC1E73ACCU-4NREYQ72XATJAREYQ72XATJABS 34BSQ36TVJADFC-15KFXSQ15TAVJUBRC1E73BS 33BSQ60TVJADFC-18EFXSQ18TAVJUBRC1E73DFC-12FFXSQ12TAVJUBRC1E73DFC-12GFXSQ12TAVJUBRC1E73ACCU-4EREYQ96XATJAREYQ96XATJABS 36BSQ36TVJADFC-09JFXSQ09TAVJUBRC1E73BS 35BSQ36TVJADFC-07HFXSQ07TAVJUBRC1E73BS 37BS4Q54TVJABCDDFC-05TFXSQ05TAVJUBRC1E73DFC-05RFXSQ05TAVJUBRC1E73DFC-05QFXSQ05TAVJUBRC1E73DFC-05SFXSQ05TAVJUBRC1E73BS 38BS4Q54TVJABCDDFC-15LFXSQ15TAVJUBRC1E73DFC-12IFXSQ12TAVJUBRC1E73DFC-12HFXSQ12TAVJUBRC1E73DFC-07FFXSQ07TAVJUBRC1E73803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:23 PME509DETAILS02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 L1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.6A 1phL1, L2 1.6A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.4A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2, L3 38.1A 3phL1, L2 0.4A 1phL1, L2 1.6A 1phL1, L2 1.6A 1phL1, L2 2.5A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.1A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 1.6A 1phL1, L2 1.4A 1phL1, L2, L3 38.1A 3phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phL1, L2 0.8A 1phOUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2BS F1,F2OUT F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2IN F1,F2F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2OUT F1,F2to centralized controllerIN F1,F2OUT F1,F2IN F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2F1,F2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2P1,P2ACCU-5WREYQ72XATJAREYQ72XATJABS 44BS4Q54TVJABCDDFC-12NFXSQ12TAVJUBRC1E73DFC-05ABFXSQ05TAVJUBRC1E73DFC-05ACFXSQ05TAVJUBRC1E73BS 43BS6Q54TVJABCDEFDFC-18FFXSQ18TAVJUBRC1E73DFC-05AAFXSQ05TAVJUBRC1E73DFC-05ZFXSQ05TAVJUBRC1E73DFC-07JFXSQ07TAVJUBRC1E73DFC-05YFXSQ05TAVJUBRC1E73DFC-05APFXSQ05TAVJUBRC1E73ACCU-5SREYQ72XATJAREYQ72XATJABS 50BS4Q54TVJABCDDFC-09NFXSQ09TAVJUBRC1E73DFC-05AMFXSQ05TAVJUBRC1E73DFC-05ALFXSQ05TAVJUBRC1E73DFC-05AKFXSQ05TAVJUBRC1E73BS 49BS4Q54TVJABCDDFC-05ANFXSQ05TAVJUBRC1E73DFC-09MFXSQ09TAVJUBRC1E73DFC-09KFXSQ09TAVJUBRC1E73ACCU-5NREYQ96XATJAREYQ96XATJABS 45BS4Q54TVJABCDDCF-18GFXSQ18TAVJUBRC1E73DFC-18HFXSQ18TAVJUBRC1E73DFC-36BFXSQ36TAVJUBRC1E73BS 46BSQ36TVJADFC-05AEFXSQ05TAVJUBRC1E73BS 48BSQ60TVJADFC-07GFXSQ07TAVJUBRC1E73DFC-05ADFXSQ05TAVJUBRC1E73DFC-18MFXSQ18TAVJUBRC1E73DFC-15PFXSQ15TAVJUBRC1E73ACCU-5EREYQ72XATJAREYQ72XATJABS 47BS8Q54TVJABCDEFGHDFC-12OFXSQ12TAVJUBRC1E73DFC-05AQFXSQ05TAVJUBRC1E73DFC-05AIFXSQ05TAVJUBRC1E73DFC-05AJFXSQ05TAVJUBRC1E73DFC-05AHFXSQ05TAVJUBRC1E73DFC-09LFXSQ09TAVJUBRC1E73DFC-005AFFXSQ05TAVJUBRC1E73DFC-05AGFXSQ05TAVJUBRC1E73803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:25 PME510DETAILS02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 LIGHTING CONTROLPANEL SCHEDULEPANEL NAME VOLTAGE LOCATIONLCP-1 120 ELECT 142RELAYLOAD NAMEWATTS LOAD TYPE CIRCUIT NOTES1 EXTERIOR BLDG LIGHTS200 LED EP-1A/142,62 EXTERIOR BLDG LIGHTS435 LED EP-1A/152,63 1ST FLR CORRIDOR EM LTS 320 LED EP-1A/22,3,441ST FLR QUICK CARE WAITING EMLTS140 LED EP-1A/102,3,4,551ST FLR QUICK CARE CORRIDOREM LTS280 LED EP-1A/102,3,4,56 1ST FLR LOBBY EM LTS338 LED EP-1A/112,3,4,57 1ST FLR BLOOD DRAW LTS 220 LED PP1B/72,4,58 1ST FLR CORRIDOR LTS440 LED PP1B/52,49 QUICK CARE EXAM RMS560 LED SBP-1A/572,510 QUICK CARE CORRIDOR627 LED SBP-1A/582,4,511QUICK CARE LOBBY388 LED SBP-1A/592,4,5121ST FLR LOBBY506 LED PP1B/92,4,5131415SITE LIGHTING1856 LED PP1A/31,332,616SITE LIGHTING1624 LED PP1A/32,342,6NOTES1. SUNSET ON/ SUNRISE OFF2. OWNER PROVIDED OPERATION SCHEDULE3. DIM TO 20% AFTER HOURS4. OCCUPANCY SENSOR CONTROL5. LOCAL DIMMER STATION CONTROL6. PHOTOCELL ON, PHOTOCELL OFFGENERAL NOTESA. MASTER DIMMING PANEL FOR PROGRAMMING AND TIMESCHEDULING THE ENTIRE SYSTEM.B. COORDINATE DIMMING SCENES AND TIME SCHEDULESWITH OWNER.C. CONSTRACTOR SHALL CONFIRM WIRE SIZES WITHVOLTAGE DROP CALCULATIONS BASED ON INSTALLEDCIRCUIT LENGTHS.D. PROVIDE 0-10V CONTROL CARDS AS REQUIRED.E. PROVIDE CONTROL PROCESSOR WITH BATTERY BACKUPLIGHTING CONTROLPANEL SCHEDULEPANEL NAMEVOLTAGE LOCATIONLCP-2 120 ELECT 243RELAYLOAD NAMEWATTS LOAD TYPE CIRCUIT NOTES1 2ND FLR CORRIDOR/LOBBY EM LTS 600 LED EP-2A/32,3,4,52 2ND FLR CORRIDOR EM LTS 260 LED EP-2A/22,3,4,53WAITING 201 EM LTS100 LED EP-2A/22,3,4,54 2ND FLR CORRIDOR LTS300 LED PP2B/372,4,55 CIRCULATION CORRIDOR 207 520 LED PP2B/302,4,56NURSE 214 LTS120 LED PP2B/302,4,57WAITING 201 LTS220 LED PP2B/312,4,58 QUICK CARE EXAM RMS570 LED PP2B/292,5910111213141516LIGHTING CONTROLPANEL SCHEDULEPANEL NAME VOLTAGE LOCATIONLCP-3 120 ELECT 323RELAYLOAD NAMEWATTS LOAD TYPE CIRCUIT NOTES1 3RD FLR CORR EM LTS320 LED EP-3A/32,3,4,52 3RD FLR CORRIDOR EM LTS 288 LED EP-3A/32,3,4,533RD FLR RECEPTION/CIRCULATIONEM LTS400 LED EP-3A/32,3,4,54 3RD FLR CORRIDOR LTS540 LED PP3B/342,4,55 3RD FLR CORRIDOR LTS338 LED PP3B/312,4,56NURSE 317E52LED PP3B/312,4,57NURSE 317B250 LED PP3B/312,4,58 3RD FLR EXAM ROOMS343 LED PP3B/352,59 3RD FLR EXAM ROOMS441 LED PP3B/352,510 3RD FLR EXAM ROOMS196 LED PP3B/322,511CIRCULATION 300570 LED PP3B/332,4,51213141516LIGHTING CONTROLPANEL SCHEDULEPANEL NAME VOLTAGE LOCATIONLCP-5 120 ELECT 523RELAYLOAD NAMEWATTS LOAD TYPE CIRCUIT NOTES1 5TH FLR CORR EM LTS320 LED EP-5A/22,3,4,52 5TH FLR CORRIDOR EM LTS 288 LED EP-5A/32,3,4,535TH FLR RECEPTION/CIRCULATIONEM LTS400 LED EP-5A/42,3,4,54 5TH FLR CORRIDOR LTS540 LED PP5A/432,4,55 5TH FLR CORRIDOR LTS338 LED PP5A/452,4,56NURSE 517E52LED PP5A/452,4,57NURSE 517B250 LED PP5A/452,4,58 5TH FLR EXAM ROOMS343 LED PP5A/442,59 5TH FLR EXAM ROOMS441 LED PP5A/462,510 5TH FLR EXAM ROOMS196 LED PP5A/322,511CIRCULATION 500570 LED PP5A/472,4,512EXTERIOR SIGNAGELED PP5A/55213EXTERIOR SIGNAGELED PP5B/18214EXTERIOR SIGNAGELED PP5B/1921516LIGHTING CONTROLPANEL SCHEDULEPANEL NAMEVOLTAGE LOCATIONLCP-4 120 ELECT 430RELAYLOAD NAMEWATTS LOAD TYPE CIRCUIT NOTES1 4TH FLR ELEV LOBBY/CORR EM LTS 300 LED EP-4A/22,3,42 4TH FLR CORR EM LTS480 LED EP-4A/32,3,4,534TH FLR RECEPTION/CIRCULATIONEM LTS400 LED EP-4A/42,3,4,54 4TH FLR ELEV LOBBY/CORR LTS 400 LED SBP-4A/102,4,554TH FLR MULTI DISCPLINE CORRLTS140 LED SBP-4A/62,4,564TH FLR CORR LTS360 LED PP4B/232,4,57 4TH FLR EXAM RM LTS280 LED PP4B/232,58 4TH FLR EXAM RM LTS500 LED PP4B/222,59 4TH FLR PROCEDURE RM LTS 414 LED SBP-4A/462,510 REGISTRATION 402 LTS400 LED PP4B/212,4,511 IMAGING LOUNGE 401300 LED PP4B/212,4,51213141516TCTIMECLOCKASTRONOMIC, DIGITAL, 7 DAYLCP-1MASTER RELAY PANEL20A/1P120VLINE VOLTAGELIGHTING CIRCUITSCAT 6ALOADLOADDIMSDDIMMING MODULEDIGITAL SWITCHPCCPHOTOCELL MODULEPHOTOCELL PHOTOCELL(OPTIONAL) CAT 6ALCP-2SLAVE RELAY PANELLOADLOADLCP-3SLAVE RELAY PANELLOADLOADLCP-4SLAVE RELAY PANELLOADLOADCAT 6ALINE VOLTAGELIGHTING CIRCUITSLINE VOLTAGELIGHTING CIRCUITSLINE VOLTAGELIGHTING CIRCUITSSEQUENCE OF OPERATION:LIGHTS-ALL LIGHTS ARE DIMMABLE-EACH ZONE IS CAPABLE OF BEING CONTROLLED INDEPENDENTLY. ZONES TO BE FINALIZED BY OWNER.OCCUPANCY-LIGHTS AUTOMATICALLY TURN ON WHEN OCCUPANT ENTERS THE SPACE VIA LOCAL OCCUPANCY SENSOR OR INTEGRAL OCCUPANCY SENSOR. CONFIGURED TO 50% AUTO-ON-LIGHTS AUTOMATICALLY TURN OFF WHEN ROOM BECOMES VACANT VIA SET TIME ON LOCAL OCCUPANCY SENSOR OR INTEGRAL OCCUPANCY SENSOR. SHORT OFF TIME DELAY OF 1 MINUTE OR LESSMANUAL-MASTER ON/OFF & RAISE/LOWER CONTROL OF ENTIRE ROOM/ZONE-OPTIONAL ADDITIONAL CONTROL (ADD XCR 2PWH -DUAL ROCKER SWITCHES)CORRIDORS-DIM CORRIDORS TO 30% BRIGHTNESS DURING BUSINESS HOURS WHEN SPACE BECOMES VACANT VIA OCCUPANCY SENSOR.-CORRIDOR FIXTURES TO TURN OFF AFTER HOURS. SET BY OWNER.-CORRIDOR EMERGENCY FIXTURES TO DIM TO 20% AFTER HOURS FOR SECURITY NIGHT LIGHTING.LOBBY AND WAITING-AUTOMATIC OFF VIA DIGITAL TIMECLOCK-DIM TO 50% BRIGHTNESS DURING BUSINESS HOURS WHEN SPACE BECOMES VACANT VIA OCCUPANCY SENSOR-PROVIDE MANUAL CONTROL STATIONS AS NOTED IN "MANUAL" DESCRIPTION, SWITCHING SHOWN ON PLANS AND LIGHTING SYSTEM CONTROL NOTES.OFFICE AND CONFERENCE-AUTOMATIC OFF WHEN ROOM BECOMES VACANT VIA VACANCY SENSOR TIME DELAY-PROVIDE MANUAL CONTROL STATIONS AS NOTED IN "MANUAL" DESCRIPTION, SWITCHING SHOWN ON PLANS AND LIGHTING SYSTEM CONTROL NOTES.EXAM AND TREATMENT ROOMS- ROOMS TO HAVE TIME SCHEDULE OFF VIA DIGITAL TIMECLOCK TO TURN OFF FIXTURES AFTER HOURS PER OWNER SCHEDULE-PROVIDE MANUAL CONTROL STATIONS AS NOTED IN "MANUAL" DESCRIPTION, SWITCHING SHOWN ON PLANS AND LIGHTING SYSTEM CONTROL NOTES.EXTERIOR-SITE LIGHTING AND BUILDING MOUNTED LIGHTING TO BE CONTROLLED VIA DIGITAL TIMECLOCK AND PHOTOCONTROL. MOTION SENSORS TO BE PROVIDED ON FIXTURES OR REMOTE.-ADDITIONAL CONTROLS TO BE PROVIDED AS NOTED.-EXTERIOR BUILDING SIGNAGE TO BE CONTROLLED VIA DIGITAL TIMECLOCK.ADDITIONAL OPTIONS:-FOR EMERGENCY LIGHTING CONTROL ADD A VOLTAGE BARRIER TO MASTER PANELLIGHTING CONTROL SYSTEM NOTES1. INCLUDE ALL CONTROL STATIONS, POWER BOOSTERS, NETWORKING EQUIPMENT AND ALL OTHER ACCESSORIESAND WIRING REQUIRED FOR A COMPLETE SYSTEM.2. COORDINATE EXACT LOCATION , QUANTITY AND CONFIGURATION OF CONTROL STATIONS WITH OWNER.3. COORDINATE ALL TIME SCHEDULING AND SCENE PROGRAMMING WITH OWNER.4. COORDINATE EXACT DECORATIVE FIXTURE LAMPS AND LOADS TO BE CONTROLLED WITH INTERIOR DESIGNER AND ARCHITECT. MOST OF THE DECORATIVE FIXTURES ARE INCANDESCENT WITH LED LAMPS. COORDINATE FIXTURE WIRING WITH SPECIFIC LAMPS AND FIXTURES AND PROVIDE ANY NECESSARY ACCESSORIES FOR PROPER DIMMING OPERATION.5. MUST BE LISTED FOR USE WITH 0-10V LED. PROVIDE 0-10V CONTROL WIRES AS REQUIRED.6. FOLLOW MANUFACTURERS RECOMMENDED WIRING INSTRUCTIONS FOR MAXIMUM CABLE LENGTHS.7. EMERGENCY LIGHTING ZONES SHALL HAVE AUTOMATIC LOAD CONTROL RELAYS THAT SENSE NORMAL POWER FAILURE FROM THE NON-EMERGENCY LIGHTING ZONE IN THE SAME SPACE. SEE EMERGENCY LIGHTING CONTROL DIAGRAMS.8. LIGHTING CONTROL SYSTEM SHALL INTERFACE WITH FIRE ALARM SYSTEM TO BRING ALL LIGHTING ZONES TO FULL BRIGHTNESS DURING GENERAL ALARM.9. LIGHTING CONTROL SYSTEM SHALL ACCEPT PHOTOCELL INPUT FOR CONTROL OF EXTERIOR FIXTURES.10. ALL OCCUPANCY AND VACANCY SENSORS SHALL HAVE AN OFF DELAY OF 1 MINUTE.11. LIGHTING CONTROL SYSTEM TO BE OF THE FOLLOWING MANUFACTURERS:A. ILC LightLEEDerB. GREENGATE CONTROLKEEPERC. ACUITY BRANDS BLUE BOXLCP-5SLAVE RELAY PANELLOADLOADLINE VOLTAGELIGHTING CIRCUITS803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:27 PME511DETAILS02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1LIGHTING CONTROL DIAGRAMREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 JJJRADIOLOGY(X-RAY)119ACSBP-1A/19SBP-1A/19142443345WARNING LIGHTEMERGENCY X-RAY SHUT-OFFELECTRICAL CONTRACTOR TO PROVIDE LEAD LINING AROUND ALL WALL BACK BOXES EQUAL TO THICKNESS PROVIDED IN DRYWALL. MAINDISCONNECTPANEL75AGROUND CABLE (PE)MAIN 480 VTHREE PHASE SUPPLYEMERGENCY OFF BUTTONGENERATOR(SYSTEM CABINET)WARNING LIGHT CONTROLWARNING LIGHTDOOR INTERLOCK SWITCHSINGLE PHASE POWER14 BLACK14 WHITE14 GREEN14 BLACK14 WHITE14 GREEN14 BLACK14 WHITE14 GREEN14 BLACK14 WHITE14 GREENBLACK(3)GREEN(1)BLACK(3) WHITE(1)14 WHITE14 RED(2) 14 BLACK* RELAY WITH A 24 VOLT, DC COIL (NOT TO EXCEED 5 WATTS), ANDA STEERING DIODE WIRED OVER THE RELAY COIL, SUPPLIED ANDINSTALLED BY ELECTRICAL CONTRACTOR. SIEMENS TO PROVIDECONTROL SIGNAL TO RELAY. CONTRACTOR SUPPLIED ANDINSTALLED JUNSTION BOX.SIEMENSPOWER/GENRATORCABINETSUPPLIED 24V(FOR DOORSWITCH ONLY)DSSUPPLIED 24VDCLIGHTING PANEL*RELAYJUNCTION BOX6FT. PIGTAILS"X-RAY ON"LEDWARNINGLIGHTLIGHTING PANEL TOBE PROVIDED WITHSWITCH TO TURN OFFWARNING LIGHTS FORSERVICE PURPOSEELECTRICAL CONDUIT LEGENDNO.CONDUIT12345(1)1" C(1)1-1/2" C(1)2" C(1)2-1/2" C(1)3-1/2" C803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:30 PME601ENLARGEDRADIOLOGYPLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/2" = 1'-0"1ENLARGED RADIOLOGY(X-RAY) ROOMGENERAL NOTES:A. ALL WIRES SPECIFIED SHALL BE COPPER STRANDED, FLEXIBLE, THERMO-PLASTIC, COLOR CODED, CUT 10 FOOT LONG AT OUTLET BOXES, DUCT TERMINATION POINTS OR STUBBED CONDUIT ENDS. ALL CONDUCTORS, POWER, SIGNAL AND GROUND, MUST BE RUN IN A CONDUIT OR DUCT SYSTEM. ELECTRICAL CONTRACTOR SHALL RING OUT AND TAG ALL WIRES AT BOTH ENDS. WIRE RUNS MUST BECONTINUOUS COPPER STRANDED AND FREE FROM SPLICES.B. ALUMINUM OR SOLID WIRES ARE NOT ALLOWED.C. WIRE SIZES GIVEN ARE FOR USE OF EQUIPMENT. LARGER SIZES MAY BE REQUIRED BY LOCAL CODES.D. IT IS RECOMMENDED THAT ALL WIRES BE COLOR CODED, AS REQUIRED IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES.E. CONDUIT SIZES SHALL BE VERIFIED BY THE ARCHITECT, ELECTRICAL ENGINEER OR CONTRACTOR, IN ACCORDANCE WITH LOCAL OR NATIONAL CODES.F. CONVENIENCE OUTLETS ARE NOT ILLUSTRATED. THEIR NUMBER AND LOCATION ARE TO BE SPECIFIED BY OTHERS. LOCATE AT LEAST ONE CONVENIENCE OUTLET CLOSE TO THE SYSTEM CONTROL, THE POWER DISTRITBUTION UNIT AND ONE ON EACH WALL OF THE PROCEDURE ROOM. USE HOSPITAL APPROVED OUTLET OR EQUIVALENT.G. GENERAL ROOM ILLUMINATION IS NOT ILLUSTRATED. CAUTION SHOULD BE TAKEN TO AVOID EXCESSIVE HEAT FROM OVERHEAD SPOTLIGHTS. DAMAGE CAN OCCUR TO CEILING MOUNTING COMPONENTS AND WIRING IF HIGH WATTAGE BULBS ARE USED. RECOMMEND LOW WATTAGE BULBS NO HIGHER THAN 75 WATTS AND USE DIMMER CONTROLS (EXCEPT MR). DO NOT MOUNT LIGHTS DIRECTLY ABOVE AREAS WHERE CEILING MOUNTED ACCESSORIES WILL BE PARKED.H. ROUTING OF CABLE DUCTWORK, CONDUITS, ETC., MUST RUN DIRECT AS POSSIBLE OTHERWISE MAY RESULT IN THE NEED FOR GREATER THAN STANDARD CABLE LENGTHS (REFER TO THE INTERCONNECTION DIAGRAM FOR MAXIMUM USABLE LENGTHS POINT TO POINT).I. CONDUIT TURNS TO HAVE LARGE, SWEEPING BENDS WITH MINIMUM RADIUS IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES.J. A SPECIAL GROUNDING SYSTEM IS REQUIRED IN ALL PROCEDURE ROOMS BYSOME NATIONAL AND LOCAL CODES. IT IS RECOMMENDED IN AREAS WHERE PATIENTS MIGHT BE EXAMINED OR TREATED UNDER PRESENT, FUTURE, OR EMERGENCY CONDITIONS. CONSULT THE GOVERNING ELECTRICAL CODE AND CONFER WITH APPROPRIATE CUSTOMER ADMINISTRATIVE PERSONNEL TO DETERMINE THE AREAS REQUIRING THIS TYPE OF GROUNDING SYSTEM.K. THE MAXIMUM POINT TO POINT DISTANCES ILLUSTRATED ON THIS DRAWINGMUST NOT BE EXCEEDED.L. PHYSICAL CONNECTION OF PRIMARY POWER TO GE EQUIPMENT IS TO BE MADE BY CUSTOMERS ELECTRICAL CONTRACTOR WITH THE SUPERVISION OF A GE REPRESENTATIVE. THE GE REPRESENTATIVE WOULD BE REQUIRED TO IDENTIFY THE PHYSICAL CONNECTION LOCATION, AND INSURE PROPER HANDLING OF GE EQUIPMENT.M. GEHC CONDUCTS POWER AUDITS TO VERIFY QUALITY OF POWER BEING DELIVERED TO THE SYSTEM. THE CUSTOMER'S ELECTRICAL CONTRACTOR IS REQUIRED TO BE AVAILABLE TO SUPPORT THIS ACTIVITY.N. REFER TO VENDOR DRAWINGS FOR ADDITIONAL INFORMATION. OBTAIN LATEST SET OF VENDOR EQUIPMENT DRAWINGS PRIOR TO STARTING WORK. WHERE DISCREPANCIES EXIST BETWEEN THESE DRAWINGS AND VENDOR DRAWINGS THE VENDOR DRAWINGS SHALL TAKE PRECEDENCE.GENERAL NOTES -CONDUIT ROUTING:A. COORDINATE ALL CONDUIT ROUTES WITH PROJECT MANAGER, THE BUILDINGOWNER AND EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT PRIOR TO INSTALLATION.B. PROVIDE PULL BOXES IN ALL CONDUIT RUNS AS REQUIRED TO FACILITATEPULLING IN CABLES.C. PROVIDE FLOOR AND WALL CORES AS REQUIRED. PROVIDE FIRESTOPPING AT ALL FLOOR AND WALL PENETRATIONS AFTER CABLES HAVE BEEN INSTALLED.3RADIOLOGY POWER DIAGRAM2RADIOLOGY WARNING LIGHT & DOOR SWITCH DETAILREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 JJJDIAGNOSTICRADIOGRAPHY416ACSBP-4A/11SBP-4A/121443345WARNING LIGHTWARNING LIGHT42EMERGENCYX-RAY SHUT-OFFELECTRICAL CONTRACTOR TO PROVIDE LEAD LINING AROUND ALL WALL BACK BOXES EQUAL TO THICKNESS PROVIDED IN DRYWALL. * RELAY WITH A 24 VOLT, DC COIL (NOT TO EXCEED 5 WATTS), ANDA STEERING DIODE WIRED OVER THE RELAY COIL, SUPPLIED ANDINSTALLED BY ELECTRICAL CONTRACTOR. SIEMENS TO PROVIDECONTROL SIGNAL TO RELAY. CONTRACTOR SUPPLIED ANDINSTALLED JUNSTION BOX.SIEMENSPOWER/GENRATORCABINETSUPPLIED 24V(FOR DOORSWITCH ONLY)DSSUPPLIED 24VDCLIGHTING PANEL*RELAYJUNCTION BOX6FT. PIGTAILS"X-RAY ON"LEDWARNINGLIGHTLIGHTING PANEL TOBE PROVIDED WITHSWITCH TO TURN OFFWARNING LIGHTS FORSERVICE PURPOSEMAINDISCONNECTPANEL75AGROUND CABLE (PE)MAIN 480 VTHREE PHASE SUPPLYEMERGENCY OFF BUTTONGENERATOR(SYSTEM CABINET)WARNING LIGHT CONTROLWARNING LIGHTDOOR INTERLOCK SWITCHSINGLE PHASE POWER14 BLACK14 WHITE14 GREEN14 BLACK14 WHITE14 GREEN14 BLACK14 WHITE14 GREEN14 BLACK14 WHITE14 GREENBLACK(3)GREEN(1)BLACK(3) WHITE(1)14 WHITE14 RED(2) 14 BLACKWARNING LIGHT14 BLACK14 WHITE14 GREENELECTRICAL CONDUIT LEGENDNO.CONDUIT12345(1)1" C(1)1-1/2" C(1)2" C(1)2-1/2" C(1)3-1/2" C803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:34 PME602ENLARGEDRADIOGRAPHYPLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/2" = 1'-0"1ENLARGED DIAGNOSTIC RADIOGRAPHY PLANGENERAL NOTES:A. ALL WIRES SPECIFIED SHALL BE COPPER STRANDED, FLEXIBLE, THERMO-PLASTIC, COLOR CODED, CUT 10 FOOT LONG AT OUTLET BOXES, DUCT TERMINATION POINTS OR STUBBED CONDUIT ENDS. ALL CONDUCTORS, POWER, SIGNAL AND GROUND, MUST BE RUN IN A CONDUIT OR DUCT SYSTEM. ELECTRICAL CONTRACTOR SHALL RING OUT AND TAG ALL WIRES AT BOTH ENDS. WIRE RUNS MUST BECONTINUOUS COPPER STRANDED AND FREE FROM SPLICES.B. ALUMINUM OR SOLID WIRES ARE NOT ALLOWED.C. WIRE SIZES GIVEN ARE FOR USE OF EQUIPMENT. LARGER SIZES MAY BE REQUIRED BY LOCAL CODES.D. IT IS RECOMMENDED THAT ALL WIRES BE COLOR CODED, AS REQUIRED IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES.E. CONDUIT SIZES SHALL BE VERIFIED BY THE ARCHITECT, ELECTRICAL ENGINEER OR CONTRACTOR, IN ACCORDANCE WITH LOCAL OR NATIONAL CODES.F. CONVENIENCE OUTLETS ARE NOT ILLUSTRATED. THEIR NUMBER AND LOCATION ARE TO BE SPECIFIED BY OTHERS. LOCATE AT LEAST ONE CONVENIENCE OUTLET CLOSE TO THE SYSTEM CONTROL, THE POWER DISTRITBUTION UNIT AND ONE ON EACH WALL OF THE PROCEDURE ROOM. USE HOSPITAL APPROVED OUTLET OR EQUIVALENT.G. GENERAL ROOM ILLUMINATION IS NOT ILLUSTRATED. CAUTION SHOULD BE TAKEN TO AVOID EXCESSIVE HEAT FROM OVERHEAD SPOTLIGHTS. DAMAGE CAN OCCUR TO CEILING MOUNTING COMPONENTS AND WIRING IF HIGH WATTAGE BULBS ARE USED. RECOMMEND LOW WATTAGE BULBS NO HIGHER THAN 75 WATTS AND USE DIMMER CONTROLS (EXCEPT MR). DO NOT MOUNT LIGHTS DIRECTLY ABOVE AREAS WHERE CEILING MOUNTED ACCESSORIES WILL BE PARKED.H. ROUTING OF CABLE DUCTWORK, CONDUITS, ETC., MUST RUN DIRECT AS POSSIBLE OTHERWISE MAY RESULT IN THE NEED FOR GREATER THAN STANDARD CABLE LENGTHS (REFER TO THE INTERCONNECTION DIAGRAM FOR MAXIMUM USABLE LENGTHS POINT TO POINT).I. CONDUIT TURNS TO HAVE LARGE, SWEEPING BENDS WITH MINIMUM RADIUS IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES.J. A SPECIAL GROUNDING SYSTEM IS REQUIRED IN ALL PROCEDURE ROOMS BYSOME NATIONAL AND LOCAL CODES. IT IS RECOMMENDED IN AREAS WHERE PATIENTS MIGHT BE EXAMINED OR TREATED UNDER PRESENT, FUTURE, OR EMERGENCY CONDITIONS. CONSULT THE GOVERNING ELECTRICAL CODE AND CONFER WITH APPROPRIATE CUSTOMER ADMINISTRATIVE PERSONNEL TO DETERMINE THE AREAS REQUIRING THIS TYPE OF GROUNDING SYSTEM.K. THE MAXIMUM POINT TO POINT DISTANCES ILLUSTRATED ON THIS DRAWINGMUST NOT BE EXCEEDED.L. PHYSICAL CONNECTION OF PRIMARY POWER TO GE EQUIPMENT IS TO BE MADE BY CUSTOMERS ELECTRICAL CONTRACTOR WITH THE SUPERVISION OF A GE REPRESENTATIVE. THE GE REPRESENTATIVE WOULD BE REQUIRED TO IDENTIFY THE PHYSICAL CONNECTION LOCATION, AND INSURE PROPER HANDLING OF GE EQUIPMENT.M. GEHC CONDUCTS POWER AUDITS TO VERIFY QUALITY OF POWER BEING DELIVERED TO THE SYSTEM. THE CUSTOMER'S ELECTRICAL CONTRACTOR IS REQUIRED TO BE AVAILABLE TO SUPPORT THIS ACTIVITY.N. REFER TO VENDOR DRAWINGS FOR ADDITIONAL INFORMATION. OBTAIN LATEST SET OF VENDOR EQUIPMENT DRAWINGS PRIOR TO STARTING WORK. WHERE DISCREPANCIES EXIST BETWEEN THESE DRAWINGS AND VENDOR DRAWINGS THE VENDOR DRAWINGS SHALL TAKE PRECEDENCE.GENERAL NOTES -CONDUIT ROUTING:A. COORDINATE ALL CONDUIT ROUTES WITH PROJECT MANAGER, THE BUILDINGOWNER AND EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT PRIOR TO INSTALLATION.B. PROVIDE PULL BOXES IN ALL CONDUIT RUNS AS REQUIRED TO FACILITATEPULLING IN CABLES.C. PROVIDE FLOOR AND WALL CORES AS REQUIRED. PROVIDE FIRESTOPPING AT ALL FLOOR AND WALL PENETRATIONS AFTER CABLES HAVE BEEN INSTALLED.2RADIOLOGY WARNING LIGHT & DOOR SWITCH DETAIL3RADIOLOGY POWER DIAGRAMREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 FJFJMAMMOGRAPHY42715ACACSBP-4A/1REMOTE EMERGENCY OFFS.T. SWITCHWARNING LIGHTPROVIDE 3-#8 & 1-#10 E.G. IN 3/4" C 21CB1FD2WV2WH13WV1FD115MAMMOGRAPHY(STEREOTATICBIOPSY)431ACPP4B/19ACWARNING LIGHTWARNING LIGHTREMOTE EMERGENCY OFF S.T. SWITCHCB1WV1WV2WH1FD1FD2123PROVIDE 3-#8 & 1-#10 E.G. IN 3/4" CDESCRIPTION:WARNING LIGHT = 4" STANDARD BOX WITH "X-RAY ON"OR RED WARNING LAMP OVER DOOR. USE APPROVED FIXTURES - INCANDESCENTOR LED, REFER TO LOCAL CODES.(SUPPLIED & INSTALLED BY HOSPITAL'S ELECTRICAL CONTRACTOR.)HOSPITAL'S ELECTRICAL CONTRACTOR TO PROVIDE POWER TO THE LAMP, ANDA SWITCH LEG TO THE "SELENIA DIMENSIONS" GANTRY FOR CONTACT CLOSUREONLY. AN XRAY EXPOSURE WILL CLOSE CONTACT, ENERGIZING THE LIGHT.THE CONTACT RELAYS ARE RATED AT: 250VAC, 10 AMP NORMALLY OPEN,AND 10 AMP, 30VDC NORMALLY OPEN.OPTIONALDOORSWITCH = MICROSWITCH IN DOOR JAMB TO ENABLE "ROOM IN USE"LIGHT OR "X-RAY SYSTEM POWER ON" INDICATOR.NOTE: CUSTOMER MAY USE A WALL SWITCH FOR THIS PURPOSE IF DESIRED.(TYPICALLY USED ONLY WHERE REQUIRED BY CODE, OR CUSTOMER PREFERENCE)TYPICAL DOOR SWITCH/WARNING LIGHT DETAILFINISH FLOORLINEALTERNATE SIDEDOORSWITCHTWO #14 FORDOORSWITCH*CONTRACTOR TO PROVIDE 120V POWER TO LIGHT &RUN A SWITCH LEG INTO "SELENIA DIMENSIONS" GANTRYWIRE SIZES:TWO # 14 + GROUND TOWARNING LIGHT*FINISH CEILING LINE(WL) WARNING LIGHTUSE APPROVED FIXTURES-INCANDESCENT OR LEDREFER TO LOCAL CODES1/2"CONDUIT FROM WARNING LIGHT TODOORSWITCH(DS) OPTIONAL DOORSWITCHLOCATE DOORSWITCH ON HINGE SIDE OF DOOR AS REQ'D BY ANY LOCAL CODES3/4" CONDUIT TO WIREWAY OR "JB1" NEAR " SELENIA DIMENSIONS" GANTRYTYPICAL CIRCUIT BREAKER DIAGRAM*CUSTOMER MAY HAVE TO STEP-UP EXISTING INCOMING POWER WITHTRANSFORMER TO MEET HOLOGIC'S POWER SPECIFICATIONS.MUST MEET ALL ELECTRICAL SPECIFICATIONS.PLEASE VALIDATE PRIOR TO INSTALLATION, AND/OR CONSULTWITH LOCAL HOLOGIC FIELD ENGINEER OR PROTECT MANAGER PRIOR TO INSTALLATION. IF STEP-UP TRANSFORMER IS USED FOR THIS APPLICATIONTRANSFORMER MUST HAVE LESS THAN .15 OHMS OF IMPEDANCE.TO MAIN DISTRIBUTION PANELSIZE PER CODESIZE PERCODEREMOTE EMERGENCYOFF SHUNT TRIP SWITCH(IF REQUIRED)CONSULT RADIOLOGY PERSONNELCONCERNING LOCATION.OR LOCATE PER LOCAL CODES.CIRCUIT BREAKER(CB1)TO HORIZONTAL WIREWAY 'WH1'PROVIDE (2) CONDUCTOR #8 WIRES AND (1) #8 AWG GROUND WIRE WITH 36" NON -TERMINATED PIGTAILS EXTENDING FROM 'FD1'. THE SELENIA DIMENSIONS GANTRY IS TO BE PERMANENTLY WIRED.5'-0" [152cm] TO FINISH FLOOR.(OR PER LOCAL CODES)5'-0" [152cm] TO FINISH FLOOR.(OR PER LOCAL CODES)803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:38 PME603ENLARGEDMAMMOGRAPHYPLANS02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/2" = 1'-0"1ENLARGED MAMMOGRAPHY ROOM1/2" = 1'-0"2ENLARGED MAMMOGRAPHY(STEREROTATIC BIOPSY) PLAN3WARNING LIGHT DETAIL4CIRCUIT BREAKER DIAGRAMCB1DEDICATED CIRCUIT BREAKER/DISCONNECT WITH REMOTE EMERGENCY SHUNT TRIP.(SHUNT TRIP USED ONLY WHERE REQUIRED BY LOCAL CODE OR CUSTOMER)SUPPLY 200-240 VAC, 50-60 HZ, SINGLE PHASE, 40 AMP, HACR, OR UL 489 LISTEDCIRCUIT BREAKER/DISCONNECT.PROVIDE (2) CONDUCTOR #8 AWG WIRES, AND (1) #8 AWG GROUND WIRE FROM 'CB1' TO 'WH1' WITH 36" NON-TERMINATED PIGTAIL EXTENDING FROM THE END OF 'FD1'. PROVIDE CONDUIT TO 'WH1'. SIZED PER CODE. MAXIMUM LINE IMPEDANCE NOT TO EXCEED: .20 OHMS FOR 208 VAC (IEC 601-2-7, TABLE 101). SEE ELECTRICAL SPECIFICATIONS. LOCATE PER LOCAL CODE. GANTRY TO BE PERMANENTLY WIRED. THE CONNECTION OF CUSTOMER SUPPLIED POWER WIRES TO THE GANTRY IS TO BE PERFORMED BY CUSTOMER'S LICENSES ELECTRICIAN.CO1 2" DIA. GROMMETED CUTOUT IN THE END FITTING, OR COVER OF 'WH1'WH1 HORIZONTAL SURFACE RACEWAY, 1 3/4" X4 3/4" WIREMOLD 4000 SERIES OR EQUAL, DIVIDED, WITH REMOVABLE COVERS, BOTTOM OF WIREWAY AT 12" AFF. PROVIDE FULL ACCESS TO 'WV1', AND 'WV2'WV1,WV2 VERTICAL SURFACE WIREWAY, 1 3/4" X 4 3/4" WIREMOLD 400 SERIES OR EQUAL, DIVIDED, WITH REMOVABLE COVERS, PROVIDE FULL ACCESS TO 'WH1', AND CORRESPONDING FLOOR DUCT (WV1 TO FD1/WV2 TO FD2).FD1HORIZONTAL SURFACE RACEWAY, 1 3/4" X4 3/4" WIREMOLD 4000 SERIES OR EQUAL, DIVIDED, WITH REMOVABLE COVERS, PROVIDE FULL ACCESS TO 'WV1'. PROVIDE 3/4" FLEXIBLE METALLIC CONDUIT (SEALTITE OR EQUAL) TO GANTRY, AND GROMMETED OPEN END.FD2 HORIZONTAL SURFACE RACEWAY, 1 3/4" X4 3/4" WIREMOLD 4000 SERIES OR EQUAL, DIVIDED, WITH REMOVABLE COVERS, PROVIDE FULL ACCESS TO 'WV2'. PROVIDE GROMMETED OPEN END.FD2 HORIZONTAL SURFACE RACEWAY, 1 3/4" X4 3/4" WIREMOLD 4000 SERIES OR EQUAL, DIVIDED, WITH REMOVABLE COVERS, PROVIDE FULL ACCESS TO 'WV2'. PROVIDE GROMMETED OPEN END.DDEDICATED 120V, 20 AMP HOSPITAL GRADE DUPLEX OUTLET. (AQUISITION WORKSTATION). ** 120V OUTLET AND NETWORK OUTLETS FOR AWS CONSOLE MAY BE INSTALLED IN COVER OF 'FD2' NEAR END120V, 20 AMP DUPLEX OUTLET. (FOR SERVICE/TEST EQUIPMENT)WALL OUTLET BOX FOR CAT 5 CABLE. (HOSPITAL NETWORK CONNECTION). RECOMMEND HOLOGIC CONNECT FOR REMOTE DIAGNOSTIC SERVICE, SWITCH GIGABIT ETHERNET (1000BASE-T)DEDICATED OUTSIDE PHONE LINE (CUSTOMER TO DETERMINE REQUIRMENT/LOCATION)REMOTE EMERGENCY OFF SHUNT TRIP SWITCH, LOCATE PER CODE. SEE DETAIL ON THIS SHEET. 12PROVIDE 3/4" CONDUIT AS REQUIRED TO CIRCUIT BREAKER 'CB1' FROM INCOMING POWER SOURCE.PROVIDE 3/4" CONDUIT FROM 'CB1' TO 'WH1'3PROVIDE 3/4" DIAMETER FLEXIBLE METALLIC CONDUIT (SEALTITE OR EQUAL) FROM END OF 'FD1' TO BACK OF GANTRY. USE ELBOW FITTING IN END OF 'FD1'. LENGTH SHOULD ALLOW FOR A 12-18" SERVICE LOOP.ITEM DESCRIPTIONSUPPLIED AND INSTALLED BY HOSPITAL'S ELECTRICAL CONTRACTORELECTRICAL LEGENDSUPPLEMENTAL NOTESALL ITEMS LISTED BELOW ARE TO BE PROVIDED/DESIGNED BY THE ARCHITECT.THE ARCHITECT SHALL CONSULT WITH THE CUSTOMER FOR ANY ADDITIONAL INFORMATION .1. RECOMMEND INCANDESCENT OR LED, AS WELL AS FLUORESCENT LIGHT FIXTURES.THE INCANDESCENT OR LED FIXTURES SHOULD BE DISTRIBUTED AROUND THE ROOM. HOLOGIC RECOMMENDS AGAINST THE USE OF DIMMER CONTROLS, AS THEY CAN CAUSE ISSUES WITH EMI INTERFERENCE.2. IT IS RECOMMENDED THAT ALL DIAGNOSTIC ROOMS SHOULD HAVE TILE OR VINYL FLOORING.3. A TILE DROP CEILING IS RECOMMENDED FOR ANY DIAGNOSTIC ROOMS.4. ALL CABINETRY WORK IS TO BE DESIGNED AND PROVIDED BY THE ARCHITECT. RECOMMEND ALL COUNTERS HAVE ROUNDED CORNERS.GROUNDING NOTES*FIELD VERIFY ACTUAL APPLICATION WITH LOCAL LICENSED ELECTRICIAN.THE SOURCE GROUND CONNECTION FOR THIS SYSTEM WILL BE THE GROUND SIDE OF THE NEUTRAL TO GROUND BONDING POINT FOR THE POWER DELIVERED TO THIS SYSTEM. THE SOURCE WILL BE EITHER THE MAIN SERVICE ENTRANCE PANEL OR A SEPARATELY DERIVED SOURCE, SUCH AS AN ISOLATION TRANSFORMER. SYSTEM LOCALIZED COLD WATER PIPING OR BUILDING STEEL ARE NOT ACCEPTABLE GROUND SOURCE CONNECTION POINTS. THE SOURCE GROUND CONDUCTOR SHALL BE THE SAME SIZE AND TYPE AS THE PHASE CONDUCTORS SUPPLYING THE SYSTEM. REFER TO LOCAL AND NATIONAL ELECTRIC CODES FOR GROUNDING REQUIREMENTS.WIRING NOTESELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS, WIRE, WIREWAYS, DISTRIBUTION TRANSFORMER, JUNTION BOXES, ENCLOSURES, CIRCUIT BREAKERS, ETC. ALL WIRES TO BE THHN TYPE, STRANDED COPPER UNLESS OTHERWISE SPECIFIED. THE ELECTRICAL CONTRACTOR SHALL SUPPLY LUG PAIRS OF #8 AWG OR GREATER FOR ALL CABLES LISTED WITHIN THE SCOPE OF WORK. CONDUIT AND DUCT RUNS ARE SCHOWN SCHEMATICALLY. ACTUAL BUILDING CONDITIONS WILL DETERMINE CONDUIT AND DUCT ROUTES. CONDUIT TURNS TO HAVE LARGE SWEEPING BENDS WITH MINIMUM RADIUS AS SPECIFIED IN ART. 346-10. IF LARGE BENDS IN CONDUIT ARE NOT POSSIBLE, USE SERVICE ENTRANCE ELBOW CONNECTORS TO AVOID DAMAGE TO CABLE. ELECTRICAL CONTRACTOR TO PROVIDE 10'-0" TAILES FOR ALL WIRES UNLESS OTHERWISE SPECIFIED AND IDENTIFY BOTH ENDS OF ALL WIRES. ELECTRICAL CONTRACTOR SHALL MAKE EVERY EFFORT TO ENSURE THAT POINT TO POINT CONDUIT RUNS ARE AS SHORT AS FIELD CONDITIONS ALLOW. LEAVE PULL WIRE IN EMPTY CONDUITS. WORK SHALL COMPLY WITH REGULATORY AGENCIES OF JURISDICTION ALL SUCH AGENCIES SUPERSEDE THESE DRAWINGS AND MUST BE ADHERED TO. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCRUTINIZING THESE DRAWINGS AND SHALL MAKE CORRECTIONS ACCORDING TO PREVAILING CODES. NOTE: CONDUITS MAY BE INCREASED IN SIZE BUT NEVER DECREASED WITHOUT CONSENT FROM THE EQUIPMENT REPRESENTATIVES. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING THE PATIENT GROUNDING NETWORK PER NATIONAL ELECTRIC CODE ARTICLE 517 AND NFPA 70. ALL CONDUIT SHALL BE RIGID TYPE UNLESS SPECIFIED OTHERWISE IN THIS DRAWING SET. ALL CONDUIT RUNS EXPOSED TO WET ENVIRONMENTS SHALL BE MADE LIQUID TIGHT. (e.g. UNDERGROUND, ETC) ALL FLUSH MOUNTED ELECTRICAL BOXES AND WIRE TROUGHS SHALL HAVE OVERSIZED CIVER PLATES. ALL FLUSH MOUNTED ELECTRICAL BOXES AND WIRE TROUGHS EXPOSED TO A WET ENVIRONMENT SHALL BE MADE LIQUID TIGHT (e.g. IN FLOOR, ETC) THE ELECTRICAL CONTRACTOR SHALL INSTALL, PROVIDE POWER TO AND CONNECT THE FOLLOWING IF REQUIRED: THE "X-RAY IN USE" WARNING SIGN; THE 120 VAC, 15 AMP RECEPTACLE; THE DOOR INTERLOCK SWITCH; THE EMERGENCY OFF SWITCH; AND THE 120VAC, DEUPLEX OUTLETS FOR SERVICE AND HOUSEKEEPING.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021