HomeMy WebLinkAboutS504 Details & SectionsA A A MOMENT CONNECTION TO FLANGE TOP OF COLUMN WF COLUMN, SEE PLAN BEAM SEE PLAN BEAMS FRAMING FROM OTHER SIDES NOT SHOWN (N) SC BOLTS TOP AND BOTTOM FLANGE STIFFENER PLATE WELDED 3 SIDES (TYP.) MATCH FLANGE PLATE THICKNESS EXTENDED PLATE SHEAR CONNECTION TYPICAL WELDED FLANGE PLATE BEAM SEE PLAN (N) SC BOLTS TOP AND BOTTOM FLANGE BEAM SEE PLAN WELDED FLANGE PLATE BEAM-SEE PLAN FOR SIZE STANDARD SHEAR CONNECTION TYPICAL BEAMS FRAMING FROM OTHER SIDE NOT SHOWN (N) SC BOLTS TOP AND BOTTOM FLANGE STIFFENER PLATE WELDED 3 SIDES (TYP.) MATCH FLANGE PLATE THICKNESS WF COLUMN SEE PLAN (N) SC BOLTS TOP AND BOTTOM FLANGE (N) SC BOLTS TOP AND BOT. FLANGE EXTENDED PLATE SHEAR CONN. BEAM FRAMING FROM OTHER SIDE NOT SHOWN (N) SC BOLTS TYP. TOP AND BOTTOM FLANGE EXTENDED PLATE SHEAR CONN. (TYP.) WELDED FLANGE PLATE BEAM SEE PLAN WF COLUMN SEE PLAN SECTION A X CJP AS NOTED X CJP AS NOTED X CJP AS NOTED MOMENT CONNECTION TO FLANGE INTERMEDIATE BEAM MOMENT (K-FT)NPLATE (t) (IN) NOTES: 1. N = ROWS OF (2) 7/8" DIAMETER A490 SLIP CRITICAL (SC) BOLTS U.N.O. 2. PLATE WIDTH TO MATCH COLUMN WIDTH 3. CJP = COMPLETE JOINT PENETRATION WELD TYPE TC-U4a 4. FLANGE STIFFENER: Y = PROVIDE STIFFENER, N = NOT REQUIRED 5. WEB STIFFENER: PLATE R" THICK X Y" EXTENSION (N = NOT REQUIRED), Z = R, 2S = PROVIDE ON TWO SIDES OF WEB WELD (X) FLANGE STIFFENER MOMENT CONNECTION TO WEB WEB STIFF. R X Y WF COLUMN, SEE PLAN BEAM SEE PLAN FLANGE STIFFENER WEB STIFFENER, R" THICK (2S) TWO SIDES AS NOTED WELDED FLANGE PLATE BEAM SEE PLAN Z Y" TOP AND BOTTOMt t WEB STIFFENER WEB STIFFENER, R" THICK (2S) TWO SIDES AS NOTED W14X38 125 3/4"3/8"3 Y N W10 62 3/4"1/4"2 Y N W8 48 3/4"1/4"2 Y N W12X40 139 3/4"3/8"5 Y N W12X58 240 1"CJP 8 Y N W24X68 W24X62 71 3/4"5/16"3 N N W24X84 517 1"CJP 8 N N W18 398 3/4"3/8"8 N N W33 23 1/2"1/4"2 N N 25 1/2"1/4"2 N NW12X26 STANDARD SHEAR CONNECTION NUMBER OF BOLTS SHALL BE DESIGNED USING BEAM UNIFORM LOAD CAPACITIES, UNLESS BEAM REACTION IS NOTED. 3/4"DIA. A325 BOLTS, LARGER DIA. MAY BE REQ. (TYPICAL) REFER TO PLAN FOR BEAM SIZE STANDARD SHEAR CONNECTION REFER TO PLAN FOR BEAM SIZE 3/4" DIA. A325 BOLT PAIRS TO MATCH FLANGE STRENGTH WELD OPTIONAL CONTINUOUS CONNECTION SIMPLE CONNECTION PLATE =FLANGE WIDTH + 1" FLANGE THICKNESS + 1/8" PLATE =FLANGE WIDTH -1" FLANGE THICKNESS + 1/4" PL. ASTM A572 Gr.50 (TYP.) EXTENDED ENDPLATE SHEAR CONNECTION AT CONTRACTOR'S OPTION. BOLTS SHALL CARRY 100% OF ECCENTRIC MOMENT L BOLTS IN STD. HOLES EXTENDED SINGLE PLATE SHEAR CONNECTION OR DOUBLE ANGLE AT WEB REFER TO PLAN FOR BEAM SIZE 3/4" DIA. A325 BOLTS LARGER DIAMETER MAY BE REQUIRED WIDE FLANGE OR HSS COLUMN (REFER TO COLUMN SCHEDULE) STANDARD DOUBLE ANGLE SHEAR CONNECTION. DESIGN WITH BEAM UNIFORM LOAD CAPACITIES, UNLESS BEAM REACTIONS NOTED SEAL WELD CAP PLATE HSS COLUMN, REFER TO PLAN5/8" CAP PLATE CL 1/2" STIFFENER PLATE EA. SIDE OF BEAM WEB REFER TO PLAN FOR BEAM SIZE (4)-3/4" DIA. A325 BOLTS COLUMN, REFER TO PLAN 1" CAP PLATE CL (N) ROWS SC BOLTS TOP AND BOTTOM FLANGE DBL ANGLE OR EXTENDED PLATE SHEAR CONN. BEAM FRAMING FROM OTHER SIDE NOT SHOWN (N) ROWS BOLTS TOP AND BOTTOM FLANGE DBL ANGLE OR EXTENDED PLATE SHEAR CONN. (TYP.) WELDED FLANGE PLATE BEAM SEE PLAN HSS COLUMN SEE PLAN SECTION A 1/4" BEAM MOMENT (K-FT)NPLATE (t) (IN) NOTES: 1. N = ROWS OF (2) 3/4" DIAMETER A325 PRETENSIONED BOLTS U.N.O. 2. PLATE TO BE 50 KSI STEEL U.N.O. 3. EXTENDED SHEAR CONNECTION DESIGNED BY FABRICATOR'S ENGINEER MAY BE PROVIDED IN LIEU OF DBL ANGLE SHEAR CONNECTION. WELD (X) MOMENT CONNECTION TO HSS t CLIP CORNER AT 90 DEG. CONN. DOUBLE MOMENT CONNECTIONS: TIGHTEN BOLTS IN BOTTOM FLANGES AFTER DEAD LOADS APPLIED (TYP.) CJP TO COLUMN AT MOMENT CONNECTIONS t W8X28 35 1/2 1/4 3 W10X33 61 1/2 3 W12X58 133 3/4 4 W14X38 75 3/4 3 2" MIN. 6" MIN. 1/4 1/4 1/4 2" MIN. BEAM PER PLAN DOUBLE ANGLE SHEAR CONNECTION: CONNECTION DEPTH = BEAM "T" DIMENSION WITH 3/4" A325-N CJP TYP. 3 SIDES FOR OPENINGS 2'-0" SQUARE MAX SPAN OF DECK FOR OPENINGS 2'-0" TO 6'-0" SQ. MAXREFER TOPLANCL BEAM L4x4x1/4L4x4x1/4SPAN OF DECK L4x4x1/4 L4x4x1/4 L4x4x3/8L4x4x3/8 L4x4x3/8 L4x4x3/8SEAT ANGLE L4x4x3/8 x 6" CL BEAM NOTES: 1. COORDINATE EXACT OPENING SIZE AND LOCATION WITH ACTUAL EQUIPMENT USED AND WITH ARCHITECTURAL AND M.E.P. DRAWINGS. A B 2'-0" MAX 2'-0" MAX6'-0" MAX 6'-0" MAX 6'-0" MAXCOORD. WITH MECH.MAX. 4'-0"STEEL DECK ROOF BEAM, SEE PLAN THERMALLY BROKEN SPLICE (BASIS OF DESIGN: FABREEKA TIM) PIPE 4STD AT 12'-0" MAX. 1/2" STIFFENER PLATE AT EA. POST, EACH WAY W8X18 MECHANICAL UNIT SUPPORT RAIL *NOTE: ALL EXTERIOR EXPOSED STEEL TO BE HOT-DIP GALVANIZED 3/16 3/16 PROVIDE ADDITIONAL INTERMEDIATE SUPPORTS AS REQUIRED BY UNITS TO BE INSTALLED. MIN. SIZE L4X4X5/16. (NOT SHOWN)0'-10"0'-10" L3X3X1/4 KICKER AT EA. BRACE W/ 1/4" GUSSET (OMIT AT GRIDLINES "A" AND "D")BEAM, SEE PLAN PIPE 4" STD. AT 12' o.c. MAX COLD FORMED FRAMING BY OTHERS AT 24" O.C. MAX. SEE ARCH FOR PROFILES. MAY BE SITE-BUILT OR PRE-FAB TRUSSES. CLAD PER ARCH. THERMALLY BROKEN SPLICE (BASIS OF DESIGN: FABREEKA TIM) LOCATE IN APPROX. CENTER OF INSULATION. T.O. STEEL (VARIES - SEE PLAN) T.O. PARAPET (VARIES - SEE ARCH.) BEARING ELEV. (CONSTANT, SEE ARCH.) PIPE 4" STD. AT 12' o.c. MAX HSS6X6X5/16, CONT. PROVIDE ACCESS PANELS AS REQURIED FOR FALL PROTECTION ATTACHMENT POINTS. PROVIDE ATTACHEMENT LUG DIRECTLY WELDED TO HSS. OR ATTACH AROUND HORIZ HSS. STEEL FRAMING. SEE PLAN. MIN. 5'-0" COORDINATE WITH PROVIDE HURRICANE TIES AT EACH BEARING POINT. FIRE RETARDANT TREATED WOOD SHEATHING (1/2" PERFORMANCE CATEGORY). FASTEN TO COLD- FORMED FRAMING WITH COMPATIBLE FASTENERS AT 4" O.C. (EDGE) AND 12" O.C. FIELD. ROOF MEMBRANE, SEE ARCH. COLD-FORMED EXTERIOR WALL FRAMING AND/OR CURTAIN WALL SYSTEM PROVIDE DEFLECTION CLIP TO BEAM AT EACH STUD .2" TYP.L3X3X1/4 KICKER AT EA. BRACE W/ 1/4" GUSSET (OMIT AT GRIDLINES "A" AND "D") BEAM, SEE PLAN PIPE 4" STD. AT 12' o.c. MAX COLD FORMED FRAMING BY OTHERS AT 24" O.C. MAX. SEE ARCH FOR PROFILES. MAY BE SITE-BUILT OR PRE-FAB TRUSSES. CLAD PER ARCH. THERMALLY BROKEN SPLICE (BASIS OF DESIGN: FABREEKA TIM) LOCATE IN APPROX. CENTER OF INSULATION. T.O. STEEL (VARIES - SEE PLAN) T.O. PARAPET (VARIES - SEE ARCH.) BEARING ELEV. (CONSTANT, SEE ARCH.) PIPE 4" STD. AT 12' o.c. MAX HSS6X6X5/16, CONT. PROVIDE ACCESS PANELS AS REQURIED FOR FALL PROTECTION ATTACHMENT POINTS. PROVIDE ATTACHEMENT LUG DIRECTLY WELDED TO HSS. OR ATTACH AROUND HORIZ HSS. STEEL FRAMING. SEE PLAN. MIN. 5'-0" COORDINATE WITH PROVIDE HURRICANE TIES AT EACH BEARING POINT. FIRE RETARDANT TREATED WOOD SHEATHING (1/2" PERFORMANCE CATEGORY). FASTEN TO COLD- FORMED FRAMING WITH COMPATIBLE FASTENERS AT 4" O.C. (EDGE) AND 12" O.C. FIELD. ROOF MEMBRANE, SEE ARCH. COLD-FORMED EXTERIOR WALL FRAMING AND/OR CURTAIN WALL SYSTEM PROVIDE DEFLECTION CLIP TO BEAM AT EACH STUD . TOP MOUNT JOIST HANGER AT EACH JOIST 8" X 54 MIL MIN. CFMF ROOF JOISTS AT 24" O.C. MAX. INFILL CFMF MIN. (1) LAYER FIRE RETARDANT SHEATHING (3/4" PERFORMANCE CATEGORY) FASTEN TO COLD-FORMED FRAMING WITH COMPATIBLE FASTENERS AT 4" O.C. (EDGE) AND 12" O.C. FIELD. MAKE UP ELEV. WITH ADDITIONAL LAYERS OR HAT CHANNELS TO PRODUCE SURFACE FLUSH WITH TOP OF DECK. DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com phone: (585) 482-8130 www.jensenbrv.com ROCHESTER, NEW YORK 14609 1653 EAST MAIN STREET Structural Engineering Consultants2/10/2021 4:47:16 PMS504 DETAILS AND SECTIONS 02/05/2021 2018089 NH Carpenter Park, Ithaca, NY 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/4" = 1'-0"5 TYPICAL MOMENT CONNECTIONS AT W-COL. 3/4" = 1'-0"1 BEAM TO BEAM CONN. 3/4" = 1'-0"2 BEAM TO COLUMN CONNECTION 3/4" = 1'-0"3 BEAM OVER COLUMN CONNECTION 3/4" = 1'-0"4 TYPICAL MOMENT CONNECTIONS AT HSS 3/4" = 1'-0"6 FR MOMENT SPLICE 3/4" = 1'-0"7 TYPICAL FRAMING AT OPENINGS 3/4" = 1'-0"8 MECHANICAL UNIT RAILS 3/4" = 1'-0"9 PARAPET FRAMING - BEAMS PARALLEL 3/4" = 1'-0"10 PARAPET FRAMING - BEAMS PARALLEL AT GRID 1 REVISION SCHEDULE NAME DATE 02/10/2021 Received by DiMarco 2/15/2021