Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
00 Cover Page & TOC
PROJECT MANUAL Park Grove – Cayuga Medical Center MEDICAL OFFICE BUILDING Cayuga Park, Ithaca, NY 14850 HOLT Project #: 2018089 Date: 5 February 2021 (Revised 2/24/2021) HOLT Architects, P.C. Architects, Planners, and Interior Designers 619 W. State Street, Ithaca, NY 14850 | 607.273.7600 | www.holt.com Jensen / BRV Engineering Structural Engineering 1653 Main Street, Rochester, NY 14609 | Tel 585.482.8130 | www.jensenbrv.com EC4B Engineering Mechanical, Electrical, Plumbing & Fire Protection Engineering 15 Schoen Place, Suite, Pittsford, NY 14534 | Tel 607.6734.8492 | www.ec4b.com Received by DiMarco 02/25/2021 Park Grove - Cayuga Medical Center MEDICAL OFFICE BUILDING Cayuga Park, Ithaca, NY 14850 HOLT Project No. 2018089 Table of Contents TOC - 1 TABLE OF CONTENTS DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS SECTION 003132 - GEOTECHNICAL AND CONTROLLED MODULUS COLUMN (CMC) RIGID INCLUSION INFORMATION SECTION 004322 - UNIT PRICE SECTION 004383 - MILESTONE SCHEDULE AND CRITICAL SUBMITTALS SECTION 006319 - REQUEST FOR EQUIVALENT REVIEW FORM (PRE-BID) DIVISION 01 - GENERAL REQUIREMENTS SECTION 011000 - SUMMARY SECTION 011419 - USE OF SITE SECTION 012300 - ALTERNATES SECTION 012500 - SUBSTITUTION PROCEDURES SECTION 012410 - RFI FORM SECTION 012653 - LABOR RATE WORKSHEET SECTION 012976 - PROGRESS PAYMENT SECTION 013000 - CONSTRUCTION PROCEDURES AND CONTROLS SECTION 013113 - CONTRACT COORDINATION SECTION 013216 - CONTRACTOR’S CONSTRUCTION SCHEDULE SECTION 013219 - SUBMITTAL PROCEDURES SECTION 013500 - ELECTRONIC DOCUMENT TRANSFER SECTION 013523 - PROJECT SAFETY STANDARDS SECTION 014000 - QUALITY REQUIREMENTS SECTION 014200 - REFERENCES SECTION 014339 - MOCKUP REQUIREMENTS SECTION 014533 - SPECIAL INSPECTIONS & TESTING SECTION 015000 - TEMPORARY FACILITIES AND CONTROLS SECTION 015500 - ACCESS ROADS, PARKING AND STAGING SECTION 015690 - CONSTRUCTION CLEANING SECTION 017116 - ACCEPTANCE OF EXISTING CONDITIONS SECTION 017329 - CUTTING AND PATCHING SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL SECTION 017423 - FINAL CONSTRUCTION CLEANING SECTION 017700 - CLOSEOUT PROCEDURES SECTION 017823 - OPERATION AND MAINTENANCE DATA SECTION 017839 - PROJECT RECORD DOCUMENTS SECTION 017900 - DEMONSTRATION AND TRAINING SECTION 018113.14 - SUSTAINABLE DESIGN REQUIREMENTS - LEEDV4 BD+C SECTION 019113 - GENERAL COMMISSIONING SECTION 019119 - BUILDING ENCLOSURE COMMISSIONING REQUIREMENTS DIVISION 03 - CONCRETE SECTION 033000 - CAST-IN-PLACE CONCRETE SECTION 034100 - PRECAST STRUCTURAL CONCRETE Received by DiMarco 02/25/2021 Park Grove - Cayuga Medical Center MEDICAL OFFICE BUILDING Cayuga Park, Ithaca, NY 14850 HOLT Project No. 2018089 Table of Contents TOC - 2 DIVISION 04 - MASONRY SECTION 042000 - UNIT MASONRY SECTION 047200 - CAST STONE MASONRY DIVISION 05 - METALS SECTION 051200 - STRUCTURAL STEEL FRAMING SECTION 053100 - STEEL DECKING SECTION 054000 - COLD-FORMED METAL FRAMING SECTION 055000 - METAL FABRICATIONS SECTION 055113 - METAL PAN STAIRS SECTION 055813 - COLUMN COVERS SECTION 057300 - DECORATIVE METAL RAILINGS DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES SECTION 060660 - PLASTIC FABRICATIONS SECTION 061053 - MISCELLANEOUS ROUGH CARPENTRY SECTION 061600 - SHEATHING SECTION 062614 - MINERAL PROFILE PANELING SECTION 064116 - PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS DIVISION 07 - THERMAL AND MOISTURE PROTECTION SECTION 071326 - SELF-ADHERING SHEET WATERPROOFING SECTION 072100 - THERMAL INSULATION SECTION 072119 - FOAMED-IN-PLACE INSULATION SECTION 072500 - WEATHER BARRIERS SECTION 072726 - FLUID-APPLIED MEMBRANE AIR BARRIERS SECTION 074213.23 - METAL COMPOSITE MATERIAL WALL PANELS SECTION 074623 - WOOD RAINSCREEN SIDING SECTION 075423 - THERMOPLASTIC-POLYOLEFIN (TPO) ROOFING SECTION 076200 - SHEET METAL FLASHING AND TRIM SECTION 077100 - ROOF SPECIALTIES SECTION 077200 - ROOF ACCESSORIES SECTION 078100 - APPLIED FIREPROOFING SECTION 078123 - INTUMESCENT FIREPROOFING SECTION 078413 - PENETRATION FIRESTOPPING SECTION 078443 - JOINT FIRESTOPPING SECTION 079200 - JOINT SEALANTS SECTION 079219 - ACOUSTICAL JOINT SEALANTS DIVISION 08 - OPENINGS SECTION 081113 - HOLLOW METAL DOORS AND FRAMES SECTION 081416 - FLUSH WOOD DOORS SECTION 081473.20 - WOOD SLIDING DOOR ASSEMBLIES SECTION 083113 - ACCESS DOORS AND FRAMES SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Received by DiMarco 02/25/2021 Park Grove - Cayuga Medical Center MEDICAL OFFICE BUILDING Cayuga Park, Ithaca, NY 14850 HOLT Project No. 2018089 Table of Contents TOC - 3 SECTION 084413 - GLAZED ALUMINUM CURTAIN WALLS SECTION 085800 - ALUMINUM SLIDING SERVICE WINDOWS SECTION 087100 - DOOR HARDWARE SECTION 087113 - AUTOMATIC DOOR OPERATORS SECTION 088000 - GLAZING SECTION 088113 - DECORATIVE GLASS GLAZING SECTION 088810 - FIRE RATED GLASS AND FRAMING SECTION 088813 - FIRE-RESISTANT GLAZING DIVISION 09 - FINISHES SECTION 092116.23 - GYPSUM BOARD SHAFT WALL ASSEMBLIES SECTION 092216 - NON-STRUCTURAL METAL FRAMING SECTION 092900 - GYPSUM BOARD SECTION 093013 - CERAMIC TILING SECTION 095113 - ACOUSTICAL PANEL CEILINGS SECTION 095429 - WOOD PANEL CEILINGS SECTION 096513 - RESILIENT BASE AND ACCESSORIES SECTION 096516 - RESILIENT SHEET FLOORING SECTION 096519 - RESILIENT TILE FLOORING SECTION 096613 - PORTLAND CEMENT TERRAZZO FLOORING SECTION 096813 - TILE CARPETING SECTION 097200 - WALL COVERINGS SECTION 097723 - FABRIC-WRAPPED PANELS SECTION 099113 - EXTERIOR PAINTING SECTION 099123 - INTERIOR PAINTING DIVISION 10 - SPECIALTIES SECTION 101419 - DIMENSIONAL LETTER SIGNAGE SECTION 102123 - CUBICLE CURTAINS AND TRACK SECTION 102239 - FOLDING PANEL PARTITIONS SECTION 102600 - WALL AND DOOR PROTECTION SECTION 102800 - TOILET, BATH, AND LAUNDRY ACCESSORIES SECTION 103100 - MANUFACTURED FIREPLACES SECTION 104413 - FIRE PROTECTION CABINETS SECTION 104416 - FIRE EXTINGUISHERS SECTION 105100 - PHENOLIC LOCKERS SECTION 107100 - ALUMINUM EXTERIOR SUN CONTROL DEVICES DIVISION 12 - FURNISHINGS SECTION 122413 - ROLLER WINDOW SHADES SECTION 123623.13 - PLASTIC-LAMINATE-CLAD COUNTERTOPS SECTION 123661.16 - SOLID SURFACING COUNTERTOPS DIVISION 13 - SPECIAL CONSTRUCTION SECTION 134900 - RADIATION PROTECTION Received by DiMarco 02/25/2021 Park Grove - Cayuga Medical Center MEDICAL OFFICE BUILDING Cayuga Park, Ithaca, NY 14850 HOLT Project No. 2018089 Table of Contents TOC - 4 DIVISION 14 - CONVEYING EQUIPMENT SECTION 142123.16 - MACHINE-ROOM-LESS ELECTRIC TRACTION PASSENGER ELEVATORS DIVISION 22 - PLUMBING & FIRE PROTECTION SECTION 220100 - BASIC PLUMBING AND FIRE PROTECTION REQUIREMENTS SECTION 220150 - EXCAVATION AND BACKFILL SECTION 220190 - ELECTRIC WIRING SECTION 220600 - PIPING SYSTEMS AND ACCESSORIES SECTION 220700 - UNDERGROUND PIPING – EXTERIO BUILDING PIPING SECTION 220800 - PLUMBING COMMISSIONING SECTION 221000 - VALVES SECTION 221600 - PUMPS SECTION 221900 - PLUMBING IDENTIFICATION SECTION 225000 - INSULATION SECTION 223300 - WET FIRE SPRINKLER SYSTEM SECTION 223750 - FIRE STANDPIPE SYSTEM SECTION 224100 - WATER SUPPLY SECTION 224110 - WASTE WATER SYSTEM SECTION 224400 - PLUMBING FIXTURES AND TRIM SECTION 224500 - EQUIPMENT SECTION 224580 - DOMESTIC WATER HEATERS SECTION 229900 - ADJUSTING AND BALANCING DIVISION 23 - HEATING, VENTILATING, AND AIR-CONDITIONING (HVAC) SECTION 230100 - BASIC MECHANICAL REQUIREMENTS SECTION 230180 - MOTORS SECTION 230190 - ELECTRIC WIRING SECTION 230600 - PIPING SYSTEMS AND ACCESSORIES SECTION 230800 - MECHANICAL COMMISSIONING SECTION 231900 - MECHANICAL IDENTIFICATION SECTION 232500 - INSULATION SECTION 237730 - VARIABLE REFRIGERANT SYSTEM SECTION 237736 - VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM ADVANCED MULTI-ZONE CONTROLLER SECTION 237750 - PACKAGED ROOFTOP HEAT RECOVERY UNIT SECTION 237810 - WALL MOUNTED ROOM AIRCONDITIONING UNIT (AIR COOLED) SECTION 238320 - UNIT HEATERS AND CABINET UNIT HEATERS (HYDRONIC AND ELECTRIC) SECTION 238600 - FANS SECTION 238900 - SHEET METAL AND DUCTWORK ACCESSORIES CONSTRUCTION SECTION 238950 - ROOF CURBS SECTION 239110 - FIRE AND SMOKE DAMPERS SECTION 239400 - REGISTERS AND DIFFUSERS SECTION 239720 - HVAC CONTROLS SYSTEMS (DDC) SECTION 239900 - ADJUSTING AND BALANCING Received by DiMarco 02/25/2021 Park Grove - Cayuga Medical Center MEDICAL OFFICE BUILDING Cayuga Park, Ithaca, NY 14850 HOLT Project No. 2018089 Table of Contents TOC - 5 DIVISION 26 - ELECTRICAL SECTION 260100 - BASIC ELECTRICAL REQUIREMENTS SECTION 260110 - GENERAL PROVISIONS SECTION 260150 - WORK INCLUDED SECTION 260800 - ELECTRICAL COMMISSIONING SECTION 261000 - BASIC MATERIALS AND METHODS SECTION 261100 - RACEWAYS SECTION 261200 - CONDUCTORS SECTION 261400 - WIRING DEVICES SECTION 263210 - DRY TYPE TRANSFORMERS SECTION 264200 - SERVICE ENTRANCE SECTION 264500 - GROUNDING SECTION 264700 - LOW VOLTAGE POWER DISTRIBUTION EQUIPMENT SECTION 264850 - MOTOR STARTERS AND CONTROL DEVICES SECTION 264900 - VARIABLE FREQUENCY DRIVES SECTION 265000 - INTERIOR LIGHTING WITH LED DRIVER SECTION 266200 - POWER GENERATION SECTION 266200.1 - TRANSFER SWITHCES SECTION 267200 - POINT ADDESSIBLE FIRE ALARM SECTION 267221 - FIRE ALARM RADIO RESPONDER SYSTEM Received by DiMarco 02/25/2021