Loading...
HomeMy WebLinkAboutP402 SchedulesFIXTURE SCHEDULEWATER CLOSETSMARKFIXTUREMAKEMODELMOUNTINGTYPEMAXIMUM GPFADAACCESSORIESWC-AELONGATEDWATER CLOSET3043.001FLOORFLUSH VALVEYES2. CHURCH MODEL 9500SSC SEAT (LESS COVER)LAVATORIESMARKFIXTUREMAKEMODELMOUNTINGNOMINAL DIMENSIONS(LxWxD)BOWL SIZE (LxWxD) ADAACCESSORIESLAV-AVITREOUSCHINA LAVATORYKOHLERK-2084WALL20"x18"18"x13"x4-1/8" YES2. JAY R. SMITH SERIES 0700 CARRIER3. MOUNT FIXTURE AT ADA HEIGHT AND PROVIDE BROCAR 500R INSULATION COVERINGSSINKSMARKFIXTUREMAKEMODELMOUNTINGNOMINAL DIMENSIONS(LxW)BOWL SIZE (LxWxD)ADA ACCESSORIESSINK-ASINGLE BOWLACRYLIC-POLYESTER (EXAM ROOMS)CORIAN ELEMENTS8254LAY-INCOUNTERTOP19-1/2x14-3/818x12-3/4x5 YES1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPMSINK-BSINGLE BOWLSTAINLESSSTEEL SINKELKAY"LUSTERTONE"LRAD-1918LAY-INCOUNTERTOP19x1816x11-1/2x6-1/2 YESSINK-CDOUBLE BOWLSTAINLESSSTEEL SINKELKAY"DAYTON"D2251925x19x6-5/1610x14x6-1/8MSS-AMOP SERVICESINKFIATMSB-2424FLOOR24x2424x24x10NO1. CHICAGO MODEL 897-CCP WALL MOUNTED FAUCET & VACUUM BREAKER & PAIL HOOK2. PROVIDE FIAT MODEL 889-CC MOP BRACKET3. PROVIDE FIAT MODEL E-77-AA RIGID VINYL BUMPER GUARDSELECTRIC WATER COOLERS & BOTTLE FILLERSMARK FIXTUREMAKEMODELSINGLE ORDOUBLEWALL ORFLOORRECESSED ORSURFACEHEIGHTWIDTHDEPTHGPH @80°FADA ACCESSORIES1. VOLTS - 1152. Hp - 1/53. Hz - 604. SINGLE PHASESHOWERS AND TUBSMARK FIXTURE MAKEMODELMATERIAL WIDTH DEPTH HEIGHT ADAACCESSORIESSHR-ASHOWERCOMFORT DESIGNSST 3838 TR RRF .75GEL COAT 38-1/2"37-3/16"79" YES2. AMERICAN STANDARD RU101SS FLASH ROUGH VALVE 1. AMERICAN STANDARD HAND HELD SHOWER SYSTEM MODEL TU662SG.213, ADA 1.5 GPMPUMPSMARKTYPEQTY. LOCATION SERVICE FLUIDGPM HEADHP VOLTS PHASE MAKE MODELREMARKSESP-1ELEVATOR SUMPPUMP(SUBMERSIBLE)2ELEVATORINDIRECT WASTESYSTEMWATER50 25 FT 3/41151ELV290WATER HEATERSMARK TYPEQTY. LOCATIONGAL. WIDTH HEIGHTVENTVOLT WATT H&C MAKE MODELREMARKS---2083/4"EXPANSION TANKSMARK SERVICE LOCATION TYPETANK VOLUME CONNECTION SIZE MAX PRESS MEAN OPERATING TEMP. CHARGEMAKE MODEL ASMEGALLON INCHES PSIDEG. FPSIMIXING VALVESMARK LOCATIONCvMIN. FLOW COLD EWT HOT EWT LWT MAX PDMAKE MODEL REMARKSGPM DEG. F DEG. F DEG. F@ HOT WATER HEATERSPOWERS LFLM492-23. PROVIDE 2" SHOWER DRAIN, SEAT, REINFORCED GRAB BARSMV-11. PROVIDE TWO (2) MIXING VALVES PIPED IN PARALLEL (PER FLOOR) AT EACH HOT WATER HEATER FOR BETTER FLOW RATE AND LOW FLOW CONTROL4500HPA082KDLOCHINVAR8027" 69"MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPESDIAMETER OFVENT PIPE(INCHES)INDIVIDUAL VENT AIRFLOW RATE (CUBIC FEET PER MINUTE)MAXIMUM DEVELOPED LENGTH OF VENT (FEET)12345678910 11 12 13 14 15 16 17 18 19 201/2 952513854321111111111113/4 100 88 47 30 20 15 1097654333222211--10094654837292420171412119877661 1/4-------1008773625346403632292623211 1/2-----------10096847565605449452-------------------100HWRP-1HOT WATERRECIRCULATIONMECHANICALROOMDOMESTIC WATERSYSTEMWATER 15 31 FT 1/6 1151MAGNA 1 32-100 FNEFFENERGY STARAMERICAN STANDARD"MADERA"1.28EWC-A8YES19"ELECTRICWATERCOOLERELKAY WALLSURFACELZSTL8WSVR DOUBLEH- 38-3/8"L- 32-7/8"35-3/4"1. SLOAN "SLOAN-OPTIMA" MODEL 111-YO-1.28 ES-S TMO (SENSOR, HARD WIRE), ADA , 1.28 GPFDBP-1DOMESTIC BOOSTER PUMP(DUPLEX SYSTEM)1MECHANICALROOMDOMESTIC WATERSYSTEMWATER 226 35 PSI7-1/2 2083GRUNDFOSMPC-E 2CRE32-2-11. PROVIDE GRUNDFOS CU352 ENERGY SAVING PUMP MANAGEMENT UNITHWH-1HEAT PUMP ELECTRICWATER HEATER5 REFER TO FLOOR PLANS (1 PER FLOOR)1. PROVIDE HEAT TRAPS AS REQUIRED BY CODE2. PROVIDE INLET AND OUTLET OUTDOOR AIR KIT AND DUCT ADAPTORS3. FINAL ELECTRICAL CONNECTIONS BY ELECTRICAL CONTRACTORDET-1 DOMESTICMECHANICALROOMVERTICAL 4.5WATTS DET-12-M1FIELD CHARGE TO MATCH SYSTEM PRESSURE140.01503/4"ASMENOREMARKSNO LIBERTY1. SUBMERSIBLE SUMP PUMP WITH OIL-TECTOR CONTROLGRUNDFOSEYEWASHESPOWERS ES150MV-24040110851401101. VOLTS - 1152. Hp - 1/53. Hz - 604. SINGLE PHASEBF-A8YES5-3/8"BOTTLE FILLERELKAY WALL SURFACELZWSSM SINGLEH- 25-7/16"L- 17-15/16"8-3/16"YES1. ELKAY ALLURE SATIN STAINLESS STEEL MODEL LK7921SSS DECK MOUNTED FAUCET, 1.5 GPM, ADA5 1. PROVIDE WHERE NOTED ON THE PLANS - HYDROGUARD XP SERIES EMERGENCY TEMPERING VALVE WITH COLD WATER BYPASS1. ULTRA HIGH EFFICIENCY PUMP WITH AQUASTAT AND PUMP TIMERLAV-B INTEGRAL INTEGRAL------YES2. PROVIDE BROCAR 500R INSULATION COVERINGS1. ELKAY ALLURE SATIN STAINLESS STEEL MODEL LK7921SSS DECK MOUNTED FAUCET, 1.5 GPM, ADA.BY GENERAL CONTRACTORBY GENERAL CONTRACTORSINK-ADEDUCT ALTERNATESINGLE BOWLSTAINLESSSTEEL SINK (EXAM ROOMS)ELKAY"LUSTERTONE"LRAD-221955LAY-INCOUNTERTOP22x19-1/2 18x14x5-3/8 YES1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPM1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPM1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPMLAY-INCOUNTERTOP2. PROVIDE 44 GALLON BLADDER TANK (DBT-1) EQUAL TO THRUSH MODEL WHV 165 0.515 PSI15 PSI13 GPM6.2 GPMSINK-DDOUBLE BOWLSTAINLESSSTEEL SINKDLR291810 29x18 12x12x10NO1. ELKAY ALLURE SATIN STAINLESS STEEL MODEL LK7921SSS DECK MOUNTED FAUCET, 1.5 GPM, ADALAY-INCOUNTERTOPELKAY"LUSTERTONE"SHR-B SHOWER --- --- --- YES2. AMERICAN STANDARD RU101SS FLASH ROUGH VALVE 1. AMERICAN STANDARD HAND HELD SHOWER SYSTEM MODEL TU662SG.213, ADA 1.5 GPM3. PROVIDE 2" SHOWER DRAIN, REINFORCED GRAB BARSTILE BY OTHERTILE BY OTHERTILE BY OTHER4. PROVIDE MUSTEE MODEL 99 DURAPAN UNDER WATER HEATERWC-BELONGATEDWATER CLOSETAMERICAN STANDARD"AFWALL"2257.101.020 WALL FLUSH VALVE 1.3 YES1. SLOAN "SLOAN-OPTIMA" MODEL 111-YO-1.28 ES-S TMO (SENSOR, HARD WIRE), ADA , 1.28 GPF2. CHURCH MODEL 9500SSC SEAT (LESS COVER)3. JAY R. SMITH SERIES 0200-0500 CARRIERNOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE PLUMBING SCOPE. PIPING MATERIAL, WATER QUALITY, HOT WATER HEATER EFFICIENCY, LEGIONELLA CONTROL, WATER SENSE FIXTURES, FIXTURE WATER CONSUMPTION, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 220800 AND 019113 FOR COMMISSIONING REQUIREMENTS.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:20 PMP402SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021