HomeMy WebLinkAboutP401 SchedulesEXHIBIT "II" - EQUIPMENT INSULATION MATERIALS(NOTES ARE AT END OF EXHIBIT)SERVICEINSULATION MATERIALTHICKNESSREMARKSDOMESTIC HOT WATER TANKSCALCIUM SILICATEOR6 LB. FIBERGLASS SUITABLE FOR 450°SERVICE1-1/2" SEGMENTEDBLOCKS OR MOLDED SECTIONSSECURE BLOCKS WITH GALVANIZED STEEL BANDS, 12" O.C. SECURE FIBERGLASS WITH PINS, STUDS, OR CLIPS, THENAPPLY 2" GALVANIZED HEXAGON MESH WIRE. COVER WITH 1/4" LAYER INSULATING CEMENT. RECOVER - SEE NOTE 1DOMESTIC WATER PUMPSFLEXIBLE SHEETS1/2"INSTALL ON "BOX" FRAMING PER MANUFACTURER'S CONSTRUCTIONSPECIFICATIONS. ARRANGE FOR EASY REMOVAL AND REPLACEMENT. COAT WITH WHITE FINISHWHERE REQUIRED, PROVIDE WELDED STUDS, CLIPS OR ANGLES AS ANCHORS FOR BANDS, WIRES AND MESH.EXHIBIT "I" - PIPE INSULATION MATERIALS(NOTES ARE AT END OF EXHIBIT)SERVICEINSULATION MATERIALTHICKNESSREMARKSDOMESTIC COLD WATERGLASS FIBER ORFLEXIBLE1-1/2" AND LARGER.....1"1-1/4" AND SMALLER.....1/2"SEE NOTE 2DOMESTIC HOTAND CIRCULATION WATER(UP TO 140°)GLASS FIBER ORFLEXIBLE1-1/2" TO 8".....1-1/2"1-1/4" AND SMALLER.....1"RUNOUTS.....1"DOMESTIC HOTAND CIRCULATION WATER(OVER 140°)GLASS FIBER1-1/2" TO 8".....2"1-1/4" AND SMALLER.....1-1/2"RUNOUTS.....1-1/2"AC UNITS DRAINSAND OVERFLOWS(INDIRECT WASTE)ALL SIZES.....1/2"ROOF CONDUCTOR LINESGLASS FIBERALL SIZES.....1"INSULATE BODY OF DRAIN AND CONDUCTOR PIPING, HORIZONTAL [AND VERTICAL] DOWN TOCONNECTION BELOW GROUND FLOOR SLAB OR IN CRAWL SPACENOTES FOR EXHIBIT INOTE 1:EXPOSED INSULATION SHALL BE COVERED WITH A PVC JACKET.FLEXIBLE ALLOWED IN 1/2 IN. THICKNESS ONLY.NOTE 2:NOTES FOR EXHIBIT IINOTE 1:HANGER SPACINGPIPING MATERIALMAXIMUM HORIZONTALSPACING (FEET)MAXIMUM VERTICALSPACING (FEET)ACRYLONITRILE BUTADIENE STYRENE(ABS) PIPING410ALUMINUM TUBING1015BRASS PIPE1010CAST-IRON PIPE515CHLORINATED POLYVINYL CHLORIDE(CPVC) PIPE AND TUBING,1 INCH AND LARGER310CHLORINATED POLYVINYL CHLORIDE(CPVC) PIPE AND TUBING, 1 1/4" INCHES AND LARGER410COPPER OR COPPER-ALLOY PIPE 12 10COPPER OR COPPER-ALLOY TUBING,1 1/4 -INCH DIAMETER ANDSMALLER610COPPER OR COPPER-ALLOY TUBING 1 1/2 -INCH DIAMETER ANDLARGER10 10CROSS-LINKED POLYETHYLENE (PEX)PIPE2.67(32 INCHES)10CROSS-LINKED POLYETHYLENE/ALUMINUM/CROSS-LINKEDPOLYETHYLENE (PEX-AL-PEX) PIPE2.67(32 INCHES)4LEAD PIPECONTINUOUS4POLYETHYLENE/ALUMINUM/POLYETHYLENE (PE-AL-PE) PIPE2.67(32 INCHES)4POLYETHYLENE OF RAISEDTEMPERATURE (PE-RT) PIPE2.67(32 INCHES)10POLYPROPYLENE (PP) PIPE ORTUBING 1 INCH AND SMALLER2.67(32 INCHES)10POLYPROPYLENE (PP) PIPE ORTUBING, 1 1/4 INCHES AND LARGER410POLYVINYL CHLORIDE (PVC) PIPE410STAINLESS STEEL DRAINAGE SYSTEMS 10 10STEEL PIPE1215MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPESFIXTUREMINIMUM PIPE SIZE (INCH)BATHTUBS (60"x32" AND SMALLER)1/2BATHTUBS (LARGER THAN 60"x32") 1/2BIDET3/8COMBINATION SINK AND TRAY1/2DISHWASHER, DOMESTIC1/2DRINKING FOUNTAIN3/8HOSE BIBBS1/2KITCHEN SINK1/2LAUNDRY, 1, 2, OR 3 COMPARTMENTS1/2LAVATORY3/8SHOWER, SINGLE HEAD1/2SINKS, FLUSHING RIM3/4SINKS, SERVICE1/2URINAL, FLUSH TANK1/2URINAL, FLUSHOMETER VALVE3/4WALL HYDRANT1/2WATER CLOSET, FLUSH TANK3/8WATER CLOSET, FLUSHOMETER TANK3/8WATER CLOSET, FLUSHOMETER VALVE1WATER CLOSET, ONE PIECE1/2MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES ANDFIXTURE FITTINGSPLUMBING FIXTURE OR FIXTURE FITTINGMAXIMUM FLOW RATE ORQUANTITYLAVATORY, PUBLIC 0.5 GPM AT 60 PSISHOWER HEAD 1.8 GPM AT 80 PSISINK FAUCET 1.5 GPM AT 60 PSIURINAL0.5 GALLON PER FLUSHINGCYCLEWATER CLOSET1.28 GALLONS PER FLUSHINGCYCLEa. THE MAXIMUM HORIZONTAL SPACING OF CAST-IRON PIPE HANGERS SHALLBE INCREASED TO 10 FEET WHERE 10-FOOT LENGTHS OF PIPE AREINSTALLED.b. FOR SIZES 2 INCHES AND SMALLER, A GUIDE SHALL BE INSTALLED MIDWAYBETWEEN REQUIRED VERTICAL SUPPORTS. SUCH GUIDES SHALL PREVENTPIPE MOVEMENT IN A DIRECTION PERPENDICULAR TO THE AXIS OF THE PIPE.a.b.CONSUMPTION TOLERANCES SHALL BE DETERMINED FROM REFERENCED STANDARDS.a. WHERE THE DEVELOPED LENGTH OF THE DISTRIBUTION LINE IS 50FEET OR LESS, AND THE AVAILABLE PRESSURE AT THE METER IS 35PSI OR GREATER, THE MINIMUM SIZE OF AN INDIVIDUAL DISTRIBUTIONLINE SUPPLIED FROM A MANIFOLD AND INSTALLED AS PART OF APARALLEL WATER DISTRIBUTION SYSTEM SHALL BE ONE NOMINAL TUBESIZE SMALLER THAN THE SIZES INDICATED.CONDENSATE DRAIN SIZINGEQUIPMENT CAPACITYMINIMUM CONDENSATE PIPEDIAMETER (INCH)UP TO 20 TONS OF REFRIGERATION 3/4 INCHOVER 20 TONS TO 40 TONS OF REFRIGERATION 1 INCHOVER 40 TONS TO 90 TONS OF REFRIGERATION1 1/4 INCHOVER 90 TONS TO 125 TONS OF REFRIGERATION 1 1/2 INCHOVER 125 TONS TO 250 TONS OF REFRIGERATION 2 INCHSIZE OF PIPE IDENTIFICATIONPIPE DIAMETER(INCHES)LENGTHBACKGROUND COLORFIELD (INCHES)SIZE OF LETTERS(INCHES)3/4 TO 1 1/480.51 1/2 TO 280.752 1/2 TO 6 12 1.258 TO 10 24 2.5OVER 10 32 3.5WHERE USED, IDENTIFICATION TAPE SHALL BE AT LEAST 3 INCHES (76MM) WIDEAND HAVE WHITE OR BLACK LETTERING ON A PURPLE FIELD STATING "CAUTION:NONPOTABLE WATER - DO NOT DRINK" IDENTIFICATION TAPE SHALL BEINSTALLED ON TOP OF NONPOTABLE RAINWATER DISTRIBUTION PIPES, FASTENEDAT LEAST EVERY 10 FEET (3048 MM) TO EACH PIPE LENGTH AND RUNCONTINUOUSLY THE ENTIRE LENGTH OF THE PIPE.SLOPE OF HORIZONTAL DRAINAGE PIPESIZE(INCHES)MINIMUM SLOPE(INCH PER FOOT)2 1/2 OR LESS 1/43 TO 61/88 OR LARGER1/16MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENTSIZE OF TRAP(INCHES)SLOPE(INCHES PER FOOT)DISTANCE FROM TRAP(FEET)1 1/41/451 1/21/4621/4831/81241/816COMMON VENT SIZESPIPE SIZE(INCHES)MAXIMUM DISCHARGE FROM UPPER FIXTURE DRAIN(DFU)1 1/21242 1/2 TO 36WASTE STACK VENT SIZESTACK SIZE(INCHES)MAXIMUM NUMBER OF DRAINAGE FIXTURE UNITS(DFU)TOTAL DISCHARGE INTOONE BRANCH INTERVALTOTAL DISCHARGE FORSTACK1 1/2122242 1/2NO LIMIT83NO LIMIT244NO LIMIT505NO LIMIT756NO LIMIT100STORM DRAIN SIZINGPIPE SIZE(INCHES)CAPACITY (GPM)VERTICALDRAINSLOPE OF HORIZONTAL DRAIN1/16 INCH PER FOOT 1/8 INCH PER FOOT 1/4 INCH PER FOOT 1/2 INCH PER FOOT234152231443873955791114180811151632315311117165234331653824334448768981,1175057141,0101,42910 2,0509271,3111,8552,62312 3,2721,4802,0932,9604,18715 5,5432,5083, 5465,0167,093THE FLUSH VOLUME FOR A DUAL-FLUSH WATER CLOSET IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSHHOT WATER PIPING VOLUME AND MAXIMUM PIPING LENGTHSNOMINAL PIPE SIZE (INCHES)MAXIMUM PIPING LENGTH (FEET)VOLUME (LIQUID OUNCES PER FOOT LENGTH)PUBLIC LAVATORY FAUCETSOTHER FIXTURES AND APPLIANCES1/4 0.33 6 505/16 0.5 4 503/8 0.75 3 501/2 1.52435/821323/430.5217/840.516150.5131 1/480.581 1/2110.562 OR LARGER180.54NOTE:FIXTURE/EQUIPMENT SIZES NOTED ABOVE SHALL BE USED UNLESS OTHERWISE NOTED.FIXTURE CONNECTION SCHEDULEITEMHOT(H)COLD(C)SANITARY/WASTE(W)VENT(V)COMMENTSWATER CLOSET (VALVE)WATER CLOSET (TANK)URINALLAVATORYMOP SERVICE SINKSINKCLINICAL SERVICE SINKSHOWERTUBELECTRIC WATER COOLERHOSE BIBBWALL HYDRANTFLOOR DRAINWASHING MACHINE FITTING1 1/2"1/2"3/4"1/2"3/4"1/2" 1/2"1 1/2"1/2"1/2"1/2"3/4"3/4"1/2"1/2"3/4"1/2"1/2"4"4"2"1 1/2"3"1 1/2"3"2"2"3"1 1/2"2"2"2"2"1 1/2"1 1/2"2"2"2"2"PROVIDE CHECK VALVES ON SUPPLY LINES1 1/2"2"2"SANITARY/WASTE GLASS FIBER ALL SIZES.....1" INSULATE IN PARKING GARAGESGLASS FIBER ORFLEXIBLESEE NOTE 2EXHIBIT "A" - PIPING MATERIALS (PLUMBING)(NOTES AT END OF EXHIBIT "A")SERVICEPIPE MATERIALFITTINGSCONNECTIONSWATER SERVICEFIRE SERVICEDUCTILE IRONWITH CEMENT LININGBELL & SPIGOTMECHANICAL OR GROOVED RUBBER GASKETDOMESTIC WATER INTERIOR:LOW TEMP HOT (<120°), COLD ANDCIRCULATION (<120°) 3" AND SMALLERTYPE L COPPERWROUGHT COPPER (USE LONGRADIUS ELBOWS ONLY FOR HWRLINE; SHORT RADIUS ELBOW ARENOT ACCEPTABLE)NO-LEAD SOLDER, PRO-PRESSDOMESTIC WATER INTERIOR:HIGH TEMP HOT (>140°), COLD, ANDCIRCULATION (>140°) 3" AND SMALLERTYPE L COPPERWROUGHT COPPER (USE LONGRADIUS ELBOWS ONLY FOR HWRLINE; SHORT RADIUS ELBOW ARENOT ACCEPTABLE)NO-LEAD SOLDER, PRO-PRESSDOMESTIC WATER INTERIOR:HOT, COLD, AND CIRCULATION 4" AND LARGERSCHEDULE 40,GALVANIZED STEEL,TYPE L COPPERGALVANIZED STEEL,WROUGHT COPPERTHREADED, NO-LEAD SOLDERSANITARY, SANITARY VENT,AND STORM(BURIED)PVC PVC SOLVENT WELDEDSANITARY, AND SANITARY VENT, AND STORM (NOT BURIED)SERVICE WEIGHT ORHUBLESS CAST IRON SOIL PIPE OR TYPE DWV COPPER ORSCHEDULE 40, GALVANIZED STEEL (GROOVED)CAST IRON HUBAND SPIGOT, NO-HUBORWROUGHT COPPER;GALVANIZED DRAINAGELEAD AND OAKUM, NO-HUB NEOPRENE GASKET ANDSTAINLESS STEEL CLAMP ASSEMBLY OR NO-LEAD SOLDER; THREADED; GROOVED MECHANICALINDIRECTWASTETYPE DWV COPPER WROUGHT COPPER NO-LEAD SOLDERSUMP PUMP DISCHARGE(NON-SEWAGE MATERIAL)TYPE DWVCOPPERWROUGHT COPPERNO-LEAD SOLDERNOTES FOR EXHIBIT ANOTE 1: ALL EXPOSED PIPING WITHIN FINISHED AREAS SHALL BE PAINTED WITH A PRIMER COAT AND TWO FINISH COATS. COLOR PER ARCHITECT/OWNER.NOTE 2: USE LONG RADIUS ELBOWS ONLY FOR HOT WATER RETURN LINES. SHORT RADIUS ELBOWS ARE NOT ACCEPTABLE FOR HOT WATER RETURN LINES.NOTE 3: ON BURIED COATED STEEL PIPE, TAPE ALL JOINTS WITH SCOTCHWRAP #50, 2IN, WIDE, 50% OVERLAP. PROVIDE CATHODIC PROTECTION SYSTEM.NOTE 4: PVC, CPVC AND PEX PIPING SHALL NOT BE USED IN THE FOLLOWING LOCATIONS: MECHANICAL/BOILER ROOMS, COMMERCIAL KITCHENS, COMMERCIAL LAUNDRY ROOMS, CEILINGSPACES THAT ARE UTILIZED AS MECHANICAL SYSTEM RETURN AIR PLENUMS, ROOMS/CLOSETS WITH GAS FIRED EQUIPMENT.NOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE PLUMBING SCOPE. PIPING MATERIAL, WATER QUALITY, HOT WATER HEATER EFFICIENCY, LEGIONELLA CONTROL, WATER SENSE FIXTURES, FIXTURE WATER CONSUMPTION, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 220800 AND 019113 FOR COMMISSIONING REQUIREMENTS.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:16 PMP401SCHEDULES02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021